WorldWideScience

Sample records for ecg-gated multislice spiral

  1. ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Funke, M.; Obenauer, S.; Baum, F.; Grabbe, E.

    2003-01-01

    AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted κ statistics, extended κ statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended κ=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended κ=0.91 and 0.73, respectively), weighted κ=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not

  2. Noninvasive coronary artery imaging by multislice spiral computed tomography. A novel approach for a retrospectively ECG-gated reconstruction technique

    International Nuclear Information System (INIS)

    Sato, Yuichi; Kanmatsuse, Katsuo; Inoue Fumio

    2003-01-01

    Although the excellent spatial resolution of multislice spiral computed tomography (MSCT) enables the coronary arteries to be visualized, its limited temporal resolution results in poor image reproducibility because of cardiac motion artifact (CMA) and hence limits its widespread clinical use. A novel retrospectively electrocardiogram (ECG)-gated reconstruction method has been developed to minimize CMA. In 88 consecutive patients, the scan data were reconstructed using 2 retrospectively ECG-gated reconstruction methods. Method 1: the end of the reconstruction window (250 ms) was positioned at the peak of the P wave on ECG, which corresponded to the end of the slow filling phase during diastole immediately before atrial contraction. Method 2 (conventional method): relative retrospective gating with 50% referred to the R-R interval was performed so that the beginning of the reconstruction window (250 ms) was positioned at the halfway point between the R-R intervals of the heart cycle. The quality of the coronary artery images was evaluated according to the presence or absence of CMA. The assessment was applied to the left main coronary artery (LMCA), the left anterior descending artery (LAD, segments no.6, no.7, and no.8), the left circumflex artery (LCx, segments no.11 and no.13) and the right coronary artery (RCA, segments no.1, no.2 and no.3). The first diagonal artery (no.9-1), the obtuse marginal artery (no.12-1), the posterior descending artery (no.4-PD), the atrioventricular node branch (no.4-AV) and the first right ventricular branch (RV) were also evaluated. Of the 88 patients, 85 were eligible for image evaluation. Method 1 allowed visualization of the major coronary arteries without CMA in the majority of patients. The left coronary artery (LCA) system (segments no.5-7, no.11 and no.13) and the proximal portion of the RCA were visualized in more than 94% of patients. Artifact-free visualization of the distal portion of the LAD (segment no.8) and RCA (no.4

  3. Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Comparison with angiographic results

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi; Matsumoto, Naoya; Kato, Masahiko [Nihon Univ., Tokyo (Japan). Surugadai Hospital] [and others

    2003-04-01

    The present study was designed to investigate the accuracy of multislice spiral computed tomography (MSCT) in detecting coronary artery disease, compared with coronary angiography (CAG), using a new retrospectively ECG-gated reconstruction method that reduced cardiac motion artifact. The study group comprised 54 consecutive patients undergoing MSCT and CAG. MSCT was performed using a SOMATOM Volume Zoom (4-detector-row, Siemens, Germany) with slice thickness 1.0 mm, pitch 1.5 (table feed: 1.5 mm per rotation) and gantry rotation time 500 ms. Metoprolol (20-60 mg) was administered orally prior to MSCT imaging. ECG-gated image reconstruction was performed with the reconstruction window (250 ms) positioned immediately before atrial contraction in order to reduce the cardiac motion artifact caused by the abrupt diastolic ventricular movement occurring during the rapid filling and atrial contraction periods. Following inspection of the volume rendering images, multiplanar reconstruction images and axial images of the left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) were obtained and evaluated for luminal narrowing. The results were compared with those obtained by CAG. Of 216 coronary arteries, 206 (95.4%) were assessable; 10 arteries were excluded from the analysis because of severe calcification (n=4), stents (n=3) or insufficient contrast enhancement (n=3). The sensitivity to detect coronary stenoses {>=}50% was 93.5% and the specificity to define luminal narrowing <50% was 97.2%. The positive predictive value and the negative predictive value were 93.5% and 97.2%, respectively. The sensitivity was still satisfactory (80.6%) even when non-assessable arteries were included in the analysis. The new retrospectively ECG-gated reconstruction method for MSCT has excellent diagnostic accuracy in detecting significant coronary artery stenoses. (author)

  4. Value of 3D-Volume Rendering in the Assessment of Coronary Arteries with Retrospectively Ecg-Gated Multislice Spiral CT

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Dedden, K.; Schmitz-Rode, T.; Guenther, R.W.; Sinha, A.M.; Hoffmann, R.; Stanzel, S.

    2003-01-01

    Purpose: To assess the diagnostic value and measurement precision of 3D volume rendering technique (3D-VRT) from retrospectively ECG-gated multislice spiral CT (MSCT) data sets for imaging of the coronary arteries. Material and Methods: In 35 patients, retrospectively ECG-gated MSCT of the heart using a four detector row MSCT scanner with a standardized examination protocol was performed as well as quantitative X-ray coronary angiography (QCA). The MSCT data was assessed on segmental basis using 3D-VRT exclusively. The coronary artery diameters were measured at the origin of each main coronary branch and 1 cm, 3 cm and 5 cm distally. The minimum, maximum and mean diameters were determined from MSCT angiography and compared to QCA. Results: A total of 353 of 525 (67.2%) coronary artery segments were assessable by MSCT angiography. The proximal segments were more often assessable when compared to the distal segments. Stenoses were detected with a sensitivity of 82.6% and a specificity of 92.8%. According to the Bland-Altman method the mean differences between QCA and MSCT ranged from 0.55 to 1.07 mm with limits of agreement from 2.2 mm to 2.7 mm. Conclusion: When compared to QCA, the ability of 3D-VRT to quantitatively assess coronary artery diameters and coronary artery stenoses is insufficient for clinical purposes

  5. Refined staging in hilar bronchial neoplasms with ECG-gated multislice-CT. Case report

    International Nuclear Information System (INIS)

    Ohlmann, S.; Daliri, A.; Froelich, J.J.; Nowak, R.; Michulla, R.

    2008-01-01

    Equivocal initial CT-based staging in 2 patients with hilar bronchial neoplasms was reassessed with retrospective ECG-gated Multislice-CT and optimized examination parameters prior to definition of treatment. An initially suspected irresectable T 4 tumor with mediastinal infiltration was downstaged to T 2 in one case, while tumor infiltration into the left atrium could be confirmed in the other case. In doubtful conditions, ECG-gated multislice CT with optimized examination parameters may be helpful for refined staging in patients with hilar bronchial neoplasma, thus possibly influencing treatment strategies. (orig.)

  6. Prospective versus retrospective ECG-gated multislice CT coronary angiography: A systematic review of radiation dose and diagnostic accuracy

    International Nuclear Information System (INIS)

    Sun Zhonghua; Ng, Kwan-Hoong

    2012-01-01

    Purpose: To perform a systematic review of the radiation dose and diagnostic accuracy of prospective versus retrospective ECG-gated multislice CT coronary angiography. Materials and methods: A search of Pubmed/Medline and Sciencedirect databases for English literature was performed to identify studies comparing prospective and retrospective ECG-gated multislice CT angiography in the diagnosis of coronary artery disease. Effective dose, dose length product, image quality and diagnostic value were compared between two groups of studies. Results: 22 studies were included for analysis. The mean effective dose of prospective ECG-gated scans was 4.5 mSv (95% CI: 3.6, 5.3 mSv), which is significantly lower than that of retrospective scans, which is 13.8 mSv (95% CI: 11.5, 16.0 mSv) (p < 0.001). The mean dose length product was 225 mGy cm (95% CI: 188, 262 mGy cm) and 822 mGy cm (95% CI: 630, 1013 mGy cm) for the prospective and retrospective ECG-gated scans, respectively, indicating a statistically significant difference between these two protocols (p < 0.0001). The mean sensitivity and specificity of multislice CT angiography in the diagnosis of coronary artery disease was 97.7% (95% CI: 93.7%, 100%) and 92.1% (95% CI: 87.2%, 97%) for prospective ECG-gated scans; 95.2% (95% CI: 91%, 99.5%) and 94.4% (95% CI: 88.5%, 100%) for retrospective ECG-gated scans, respectively, with no significant difference for sensitivity but significant difference for specificity (p = 0.047). Conclusion: Multislice CT coronary angiography with prospective ECG-gating leads to a significant reduction of radiation dose when compared to that of retrospective ECG-gating, while offering comparable image quality and diagnostic value.

  7. Evaluation of the retrospective ECG-gated helical scan using half-second multi-slice CT. Motion phantom study for volumetry

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Matsumoto, Takashi; Nakanishi, Shohzoh; Hamada, Seiki; Takahei, Kazunari; Naito, Hiroaki; Ogata, Yuji

    2002-01-01

    ECG synchronized technique on multi-slice CT provide the thinner (less 2 mm slice thickness) and faster (0.5 sec/rotation) scan than that of the single detector CT and can acquire the coverage of the entire heart volume within one breath-hold. However, temporal resolution of multi-slice CT is insufficient on practical range of heart rate. The purpose of this study was to evaluate the accuracy of volumetry on cardiac function measurement in retrospective ECG-gated helical scan. We discussed the influence of the degradation of image quality and limitation of the heart rate in cardiac function measurement (volumetry) using motion phantom. (author)

  8. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    International Nuclear Information System (INIS)

    Moore, R.K.G.; Sampson, C.; MacDonald, S.; Moynahan, C.; Groves, D.; Chester, M.R.

    2005-01-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor

  9. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.K.G. [Cardiothoracic Centre, Liverpool (United Kingdom)]. E-mail: moore@roger.go-legend.net; Sampson, C. [Cardiothoracic Centre, Liverpool (United Kingdom); MacDonald, S. [Cardiothoracic Centre, Liverpool (United Kingdom); Moynahan, C. [Cardiothoracic Centre, Liverpool (United Kingdom); Groves, D. [National Refractory Angina Centre, Liverpool (United Kingdom); Chester, M.R. [National Refractory Angina Centre, Liverpool (United Kingdom)

    2005-09-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

  10. Assessment of coronary arteries in infants by 64-detector-row multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Tahara, Masahiro; Waki, Chiaki; Komatsu, Hiroaki; Hayashi, Tomohiro; Sato, Tomoyasu

    2008-01-01

    Heart rate is one of the most important factors for optimal visualization of cardiac CT. We investigated the relation between heart rate and visibility of the coronary arteries with 64-detector row multislice spiral computed tomography (MSCT). Three simulated coronary artery stenosis models (3, 4, and 5 mm) were attached to a moving heart phantom and scanned using 64-detector row MSCT. The heart rate of the phantom was varied between 60 and 150 beats per minutes (bpm). The visibility of simulated coronary arteries was assessed in comparison between cardiac half reconstruction (CHR) and multi-sector reconstruction (MSR). Then contrast-enhanced 64-detector row MSCT was performed in 16 patients under 3 years of age with congenital heart disease and Kawasaki disease without heart rate control. The visibility of coronary artery segments was graded on a three-point scale. The simulated coronary artery patency was detected in the moving phantom at maximum heart rate (150 bpm) with MSR. Minimum lumen diameter was 0.75 mm. Electrocardiogram (ECG)-gated cardiac CT was performed in 9 patients, and non-ECG-gated cardiac CT was performed in 7 patients. The origin and proximal course of coronary arteries in all 9 patients with ECG-gated acquisition were visually evaluated. 64-detector row MSCT with ECG-gated acquisition is able to visualize the origin and proximal course of coronary arteries in infants under 3 years of age. (author)

  11. Comparative study of image quality and radiation dose between prospective and retrospective ECG gating technique in coronary artery imaging with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Liu Jianxin; Liu Jian; Dou Yanbin; Wang Jichen; Sun Hongyue

    2009-01-01

    Objective: To compare the image quality and radiation dose between prospective ECG-trigering and retrospective ECG gating technique in coronary artery imaging. Methods: 33 patients suspected coronary artery disease were included in this study and divided into experimental group (prospective ECG-triggering coronary artery imaging, heart rate 0.05). The mean DLP of experimental group (234.4 mGy · cm) was DLP of control group (974.4 mGy · cm) 24.1%. The mean effective dose of prospective ECG gating coronary artery imaging was 3.2 mSv. Effective dose reduced 76.47 %. Conclusions: Prospective ECG gating coronary artery imaging can obtain the similar image quality compared with prospective ECG gating coronary artery imaging but the effective dose reduced 76.47 %. Prospective ECG gating coronary artery imaging has clinical value to peoples who are able to not accept high radiation dose and with low heart rate. (authors)

  12. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  13. The effect of pitch in multislice spiral/helical CT

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    2000-01-01

    The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensibility of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensibility of raw data interpolation in multislice spiral CT increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications. (authors)

  14. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  15. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  16. A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT

    International Nuclear Information System (INIS)

    Vembar, M.; Garcia, M.J.; Heuscher, D.J.; Haberl, R.; Matthews, D.; Boehme, G.E.; Greenberg, N.L.

    2003-01-01

    In this investigation, we describe a quantitative technique to measure coronary motion, which can be correlated with cardiac image quality using multislice computed tomography (MSCT) scanners. MSCT scanners, with subsecond scanning, thin-slice imaging (sub-millimeter) and volume scanning capabilities have paved the way for new clinical applications like noninvasive cardiac imaging. ECG-gated spiral CT using MSCT scanners has made it possible to scan the entire heart in a single breath-hold. The continuous data acquisition makes it possible for multiple phases to be reconstructed from a cardiac cycle. We measure the position and three-dimensional velocities of well-known landmarks along the proximal, mid, and distal regions of the major coronary arteries [left main (LM), left anterior descending (LAD), right coronary artery (RCA), and left circumflex (LCX)] during the cardiac cycle. A dynamic model (called the 'delay algorithm') is described which enables us to capture the same physiological phase or 'state' of the anatomy during the cardiac cycle as the instantaneous heart rate varies during the spiral scan. The coronary arteries are reconstructed from data obtained during different physiological cardiac phases and we correlate image quality of different parts of the coronary anatomy with phases at which minimum velocities occur. The motion characteristics varied depending on the artery, with the highest motion being observed for RCA. The phases with the lowest mean velocities provided the best visualization. Though more than one phase of relative minimum velocity was observed for each artery, the most consistent image quality was observed during mid-diastole ('diastasis') of the cardiac cycle and was judged to be superior to other reconstructed phases in 92% of the cases. In the process, we also investigated correlation between cardiac arterial states and other measures of motion, such as the left ventricular volume during a cardiac cycle, which earlier has been

  17. Value of cardiac multislice spiral CT for the assessment of degenerative aortic stenosis: comparison with echocardiography

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Das, M.; Muehlenbruch, G.; Guenther, R.W.; Koos, R.; Sinha, A.M.; Stanzel, S.

    2004-01-01

    Objective: To non-invasively assess the severity of aortic valve stenosis (AS) by the determination of aortic valve calcification (AVC) using multislice spiral computed tomography (MSCT). Materials and Methods: Forty-one consecutive patients (17 male, 24 female, mean age 71.0±7.9 years) with a history of AS and an aortic valve area ≤2 cm 2 underwent retrospectively ECG-gated 4-slice MSCT and echocardiography. The AVCs were quantitatively assessed using the score described by Agatston as well as by calculating the calcium mass. The echocardiographically determined aortic valve area (AVA) and the severity of AS according to the ACC/AHA guidelines were compared to the degree of a aortic valve calcifications. Pearson's correlation coefficient, cut-off values, kappa test and F-test with post hoc Boneferroni t-tests were calculated. Results: Calcium scores were significantly higher in patients with severe AS, when compared to mild or moderate AS (p<0.001). In patients suffering from severe AS, the mean Agatston score was 4125.5±1168.9 (calcium mass 904.1±263.3) while in patients with moderate and mild AS the corresponding values were 1596.3±987.0 (319.1±208.3) and 785.9±390.1 (149.1±90.2), respectively. Pearson's correlation coefficients were r-=0.75 for the Agatston score and r=-0.72 for the calcium mass. There was a moderate agreement between severity of AS according to the ACC/AHA guidelines and the degree of AS determined from AVC scores with κ=0.6091 and κ=0.6985, respectively. Conclusion: Severe AS may be differentiated from moderate or mild AS using cardiac MSCT. Extensive calcifications of the aortic valve presenting with an Agatston-Score ≥2824 (calcium mass ≥611) indicate a severe AS and should be taken as an indication for further diagnostic workup. (orig.)

  18. Multislice spiral computed tomography imaging in congenital inner ear malformations.

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Tian, Zhi-liang; Lei, Zi-qiao; Kong, Wei-jia; Feng, Gan-sheng

    2008-01-01

    The purpose of this study is to evaluate the usefulness of multislice spiral computed tomography (CT) in the diagnosis of congenital inner ear malformations. Forty-four patients with sensorineural hearing loss were examined on a Somatom Sensation 16 (Siemens) CT scanner. The 3-dimensional reconstructions and multiplanar reformation (MPR) were performed using the volume-rendering technique (VRT) on the workstation. Of the 44 patients examined for this study, 25 patients were found to be normal and 19 patients (36 ears) were diagnosed with congenital inner ear malformations. Of the malformations, the axial, MPR, and VRT images can all display the site and degree in 33 of the ears. Volume-rendering technique images were superior to the axial images in displaying the malformations in 3 ears with small lateral semicircular canal malformations. The common malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity) (5 ears), vestibular and semicircular canal malformations (14 ears), enlarged vestibular aqueduct (16 ears, 6 of which had other malformations), and internal auditory canal malformation (8 ears, all accompanied by other malformations). Multislice spiral CT allows a comprehensively assessment of various congenital inner ear malformations through high-quality MPR and VRT reconstructions. Volume-rendering technique images can display the site and degree of the malformation 3-dimensionally and intuitionisticly. This is very useful to the cochlear implantation.

  19. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  20. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  1. Application of multislice spiral CT in children urinary tract injuries

    International Nuclear Information System (INIS)

    Feng Hui; Chen Jing

    2012-01-01

    Objective: To investigate the application value of three-dimensional reconstruction technique of multislice spiral CT(MSCT) in children urinary tract injuries. Methods: Forty-three patients with urinary tract injury performed MSCT scan, and three-dimensional reconstruction technique was used for volume rendering, maximum intensity projection and multi-planar reformation, urinary tract imaging was acquired completely. The images were reviewed by two experienced radiologists. Results: Of the 43 cases,there were 5 simple contusion of kidney, 5 contusion and laceration of kidney accompanied with subcapsular haematoma, 4 contusion and laceration of kidney accompanied with perinephric haematoma, 2 contusion and laceration of kidney accompanied with adrenal haematoma, 13 shattered kidney accompanied with extravasation of urine, 3 shattered kidney accompanied with renal pedicle injury, 6 shattered kidney accompanied with ureter injury, 2 pelvic fracture accompanied with posterior urethra split, 3 contusion of urinary bladder wall accompanied with blood clot in the urinary bladder. Conclusion: MSCT has the characteristic of high scanning speed, wide overlay scope,high image quality and thin slice scan. It is an effective modality in the evaluation of children urinary tract injuries. (authors)

  2. ECG-gating in non-cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Cairo, F.

    1987-01-01

    This paper reports the results of the ECG-gating in non-cardiac digital subtraction angiography (DSA). One hundred and fifteen patients underwent DSA (126 examinations); ECG-gating was applied in 66/126 examinations: images recorded at 70% of R wave were subtracted. Artifacts produced by vascular movements were evaluated in all patients: only 40 examinations, carried out whithout ECG-gating, showed vascular artifacts. The major advantage of the ECG-gated DSA is the more efficent subtraction because of the better images superimposition: therefore, ECG-gating can be clinically helpful. On the contrary, it could be a problem in arrhytmic or bradycardic patients. ECG-gating is helpful in DSA imaging of the thoracic and abdominal aorta and of the cervical and renal arteries. In the examinations of peripheral vessels of the limbs it is not so efficent as in the trunk or in the neck

  3. The anal verge: localization with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Wei; Tang Guangjian

    2010-01-01

    Objective: To determine and evaluate the method of localization of anal verge by multislice spiral CT. To provide an imaging reference for operative guidance of low-rectal cancer. Methods Forty eight consecutive adult patients suspected of abnormalities other than rectal disease were evaluated with abdominal and pelvic CT scans since August, 2009. They were divided into two groups based on sex and age. There were 23 men and 25 women. The ages of young group were 28 to 50 years and the average age was 41 years. The ages of elderly group were 52 to 81 years and the average age was 64 years. A small cotton ball dipped with contrast media was put at the anal verge as a marker and CT scans were performed with 64-slice spiral CT scanner. The distances between the cotton balls and the lower margin of the pubis combination (La), the lower margin of the Sth sacral vertebra (Lb), the inferior aperture of minor pelvis (Lc) and the lower margin of the basement of external anal sphincter (Ld) were measured on the mid- sagittal images obtained by MPR. The averages, the standard deviations (s), the 95% and 80% confidence intervals of La, Lb, Lc and Ld were calculated. We took the intervals of ±1.96 s or ±1.28 s 0.05) between two different sex groups [male group, (10.0±1.2) mm], female group, (9.6±1.2) mm and between two age groups [young group, (9.6±1.2) mm, elderly group, (9.9±1.3) mm]. Conclusions: The lower margin of the basement of external anal sphincter was a useful anatomic landmark for localizing the anal verge, and could be definitely identified on the middle sagittal pelvic CT image. The distance between the structure and anal verge is constant enough and can be used in measuring distance from low rectal lesion to the anal verge. (authors)

  4. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  5. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2007-01-01

    Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. (orig.)

  6. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... The purpose of the study is to evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma with multi-slice spiral computed tomography (CT) by using double-arterial phase and portal venous phase enhanced scanning. Ninety-four (94) patients with hepatocellular ...

  7. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  8. General surface reconstruction for cone-beam multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Chen Laigao; Liang Yun; Heuscher, Dominic J.

    2003-01-01

    A new family of cone-beam reconstruction algorithm, the General Surface Reconstruction (GSR), is proposed and formulated in this paper for multislice spiral computed tomography (CT) reconstructions. It provides a general framework to allow the reconstruction of planar or nonplanar surfaces on a set of rebinned short-scan parallel beam projection data. An iterative surface formation method is proposed as an example to show the possibility to form nonplanar reconstruction surfaces to minimize the adverse effect between the collected cone-beam projection data and the reconstruction surfaces. The improvement in accuracy of the nonplanar surfaces over planar surfaces in the two-dimensional approximate cone-beam reconstructions is mathematically proved and demonstrated using numerical simulations. The proposed GSR algorithm is evaluated by the computer simulation of cone-beam spiral scanning geometry and various mathematical phantoms. The results demonstrate that the GSR algorithm generates much better image quality compared to conventional multislice reconstruction algorithms. For a table speed up to 100 mm per rotation, GSR demonstrates good image quality for both the low-contrast ball phantom and thorax phantom. All other performance parameters are comparable to the single-slice 180 deg. LI (linear interpolation) algorithm, which is considered the 'gold standard'. GSR also achieves high computing efficiency and good temporal resolution, making it an attractive alternative for the reconstruction of next generation multislice spiral CT data

  9. Multi detector computed tomography (MDCT) of the aortic root; ECG-gated verses non-ECG-gated examinations

    International Nuclear Information System (INIS)

    Kristiansen, Joanna; Guenther, Anne; Aalokken, Trond Mogens; Andersen, Rune

    2011-01-01

    Purpose: Motion artifacts may degrade a conventional CT examination of the ascending aorta and hinder accurate diagnosis. We quantitatively compared retrospectively electrocardiographic (ECG) -gated multi detector computed tomography (MDCT) with non-ECG-gated MDCT in order to demonstrate whether or not one of the methods should be preferred. Method: The study included seventeen patients with surgically reconstructed aortic root and reimplanted coronary arteries. All patients had undergone both non-gated MDCT and retrospectively ECG-gated MDCT employing a stringently modulated tube current with single phase image reconstruction. The incidence of motion artifacts in the left main coronary artery (LM), proximal right coronary artery (RCA), and aortic root and ascending aorta were rated using a four point scale. The effective dose for each scan was calculated and normalized to a 15 cm scan length. Statistical analysis of motion artifacts and radiation dose was performed using Wilcoxon matched pairs signed rank sum test. Results: A significant reduction in motion artifacts was found in all three vessels in images from the retrospectively ECG-gated scans (LM: P = 0.005, RCA: P = 0.015, aorta: P = 0.003). The mean normalized effective radiation dose was 3.69 mSv (±1.03) for the non-ECG-gated scans and 16.37 mSv (±2.53) for the ECG-gated scans. Conclusion: Retrospective ECG-gating with single phase reconstruction significantly reduces the incidence of motion artifacts in the aortic root and the proximal portion of the coronary arteries but at the expense of a fourfold increase in radiation dose.

  10. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    International Nuclear Information System (INIS)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T.

    2004-01-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P [de

  11. ECG-gated myocardial imaging with 201Tl

    International Nuclear Information System (INIS)

    Baehre, M.

    1980-01-01

    ECG-gated myocardial scintigraphy by means of 201 TI was performed in 11 patients. Good scintigrams could be gained by using long imaging times, but there was no additional information when compared with static images. Disadvantages were long imaging time, higher technical expenditure, and the smaller number of projections. Furthermore, there is no possibility of performing myocardial imaging under stress. (orig.) [de

  12. Measurement of ventricular function by ECG gating during atrial fibrillation

    International Nuclear Information System (INIS)

    Bacharach, S.L.; Green, M.V.; Bonow, R.O.; Findley, S.L.; Ostrow, H.G.; Johnston, G.S.

    1981-01-01

    The assumptions necessary to perform ECG-gated cardiac studies are seemingly not valid for patients in atrial fibrillation (AF). To evaluate the effect of AF on equilibrium gated scintigraphy, beat-by-beat measurements of left-ventricular function were made on seven subjects in AF (mean heart rate 64 bpm), using a high-efficiency nonimaging detector. The parameters evaluated were ejection fraction (EF), time to end-systole (TES), peak rates of ejection and filling (PER,PFR), and their times of occurrence (TPER, TPFR). By averaging together single-beat values of EF, PER, etc., it was possible to determine the true mean values of these parameters. The single-beam mean values were compared with the corresponding parameters calculated from one ECG-gated time-activity curve (TAC) obtained by superimposing all the single-beat TACs irrespective of their length. For this population with slow heart rates, we find that the values for EF, etc., produced from ECG-gated time-activity curves, are very similar to those obtained from the single-beat data. Thus use of ECG gating at low heart rates may allow reliable estimation of average cardiac function even in subjects with AF

  13. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  14. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  15. Value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Wang Kang; Zhao Zehua; Wang Zhi; Wang Weizhong; Xu Songsen; Zhang Miao; Liu Wenjin; Zhang Guozhen; Feng Dianxu

    2005-01-01

    Objective: To investigate the value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis. Methods: A total of 39 patients with clinically suspected acute appendicitis underwent surgery from February, 2002 to September, 2003. They were prospectively examined before surgery with routine CT scanning and MPVR reconstruction spiral CT. 31 cases of appendicitis were confirmed after appendectomy. CT scans and surgery-pathology reports were evaluated on a five-grade scale from hyperemic-edematous appendix to abscess (normal appendix: 0 grade). Results: The results of spiral CT MPVR reconstruction were compared with the surgical and pathologic findings at appendectomy, yielding an accuracy of 87.2%, sensitivity of 90.3%, specificity of 75%, positive predictive value of 93.3%, and negative predictive value of 66.7%, respectively. Results of routine CT yielded an accuracy of 38.5%, sensitivity of 38.7%, specificity of 37.5%, positive predictive value of 70.6%, and negative predictive value of 13.6%, respectively. MPVR reconstruction signs of 28 patients with acute appendicitis included enlarged appendix ( > 6 mm) (96.4%), appendicoliths (26.7%), caecal apical thickening (36.7%), periappendiceal inflammation (71.4%), and abscess (10.7%). Conclusion: The use of spiral CT MPVR reconstruction in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to a significant improvement in the preoperative diagnosis and maybe a decrease in surgical-pathologic severity of appendiceal disease. (authors)

  16. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  17. Simultaneous ECG-gated PET imaging of multiple mice

    International Nuclear Information System (INIS)

    Seidel, Jurgen; Bernardo, Marcelino L.; Wong, Karen J.; Xu, Biying; Williams, Mark R.; Kuo, Frank; Jagoda, Elaine M.; Basuli, Falguni; Li, Changhui; Griffiths, Gary L.

    2014-01-01

    Introduction: We describe and illustrate a method for creating ECG-gated PET images of the heart for each of several mice imaged at the same time. The method is intended to increase “throughput” in PET research studies of cardiac dynamics or to obtain information derived from such studies, e.g. tracer concentration in end-diastolic left ventricular blood. Methods: An imaging bed with provisions for warming, anesthetic delivery, etc., was fabricated by 3D printing to allow simultaneous PET imaging of two side-by-side mice. After electrode attachment, tracer injection and placement of the animals in the scanner field of view, ECG signals from each animal were continuously analyzed and independent trigger markers generated whenever an R-wave was detected in each signal. PET image data were acquired in “list” mode and these trigger markers were inserted into this list along with the image data. Since each mouse is in a different spatial location in the FOV, sorting of these data using trigger markers first from one animal and then the other yields two independent and correctly formed ECG-gated image sequences that reflect the dynamical properties of the heart during an “average” cardiac cycle. Results: The described method yields two independent ECG-gated image sequences that exhibit the expected properties in each animal, e.g. variation of the ventricular cavity volumes from maximum to minimum and back during the cardiac cycle in the processed animal with little or no variation in these volumes during the cardiac cycle in the unprocessed animal. Conclusion: ECG-gated image sequences for each of several animals can be created from a single list mode data collection using the described method. In principle, this method can be extended to more than two mice (or other animals) and to other forms of physiological gating, e.g. respiratory gating, when several subjects are imaged at the same time

  18. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  19. Diagnostic value of multi-slice spiral CT for atlantoaxial spine injuries in children

    International Nuclear Information System (INIS)

    Xia Chengde; Qin Hongwei; Li Junhong

    2009-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) for the atlantoaxial spine injuries in children. Methods: The CT findings of 21 cases with the atlantoaxial spine injuries in children were reviewed retrospectively. Results: Fractures of dens occurred in 4 cases, isolated atlantoaxial dislocation in 15 cases, subluxation of the C2/3 right vertebra facet in 1 and atlanto-occipital subluxation in 1. CT diagnosis was correct in all cases. And plain film diagnosis was correct ia 13. Conclusion: MSCT could clearly demonstrate the fractures and dislocations of the atlantoaxial spine injuries in children and correctly determine the type of the atlantoaxial spine injuries in children, MSCT is the modality of choice in diagnosis of the atlantoaxial spine injuries in children and should be performed routinely. (authors)

  20. Multislice Spiral Computed Tomography of the Heart: Technique, Current Applications, and Perspective

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wildberger, Joachim E.; Koos, Ralf; Guenther, Rolf W.

    2005-01-01

    Multislice spiral computed tomography (MSCT) is a rapidly evolving, noninvasive technique for cardiac imaging. Knowledge of the principle of electrocardiogram-gated MSCT and its limitations in clinical routine are needed to optimize image quality. Therefore, the basic technical principle including essentials of image postprocessing is described. Cardiac MSCT imaging was initially focused on coronary calcium scoring, MSCT coronary angiography, and analysis of left ventricular function. Recent studies also evaluated the ability of cardiac MSCT to visualize myocardial infarction and assess valvular morphology. In combination with experimental approaches toward the assessment of aortic valve function and myocardial viability, cardiac MSCT holds the potential for a comprehensive examination of the heart using one single examination technique

  1. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  2. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  3. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  4. Three-dimensional multislice spiral computed tomographic angiography: a potentially useful tool for safer free tissue transfer to complicated regions

    DEFF Research Database (Denmark)

    Demirtas, Yener; Cifci, Mehmet; Kelahmetoglu, Osman

    2009-01-01

    Three-dimensional multislice spiral computed tomographic angiography (3D-MSCTA) is a minimally invasive method of vascular mapping. The aim of this study was to evaluate the clinical usefulness of this imaging technique in delineating the recipient vessels for safer free tissue transfer to compli......Three-dimensional multislice spiral computed tomographic angiography (3D-MSCTA) is a minimally invasive method of vascular mapping. The aim of this study was to evaluate the clinical usefulness of this imaging technique in delineating the recipient vessels for safer free tissue transfer...... be kept in mind, especially inthe patients with peripheral vascular disease. 3D-MSCTA has the potential to replace digital subtraction angiography for planning of microvascular reconstructions and newer devices with higher resolutions will probably increase the reliability of this technique. (c) 2009...

  5. Acute myocardial ischemia after aortic valve replacement: A comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany)]. E-mail: alexander.lembcke@gmx.de; Hein, Patrick A. [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany); Enzweiler, Christian N.H. [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Klessen, Christian [Department of Radiology, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany); Dohmen, Pascal M. [Department of Cardiovascular Surgery, Charite-Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Berlin (Germany)

    2006-03-15

    We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess with subsequent compromise of the systolic blood flow in the left main coronary artery and the resulting myocardial perfusion deficit.

  6. Acute myocardial ischemia after aortic valve replacement: A comprehensive diagnostic evaluation using dynamic multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Enzweiler, Christian N.H.; Hoffmann, Udo; Klessen, Christian; Dohmen, Pascal M.

    2006-01-01

    We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess with subsequent compromise of the systolic blood flow in the left main coronary artery and the resulting myocardial perfusion deficit

  7. ECG gated magnetic resonance imaging in cardiovascular disease

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Im, Chung Kie; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    Using KAIS 0.15 Tesla resistive magnetic imaging system, ECG gated magnetic resonance (MR) image of various cardiovascular disease was obtained in 10 patients. The findings of MR image of the cardiovascular disease were analysed and the results were as follows: 1. In 6 cases of acquired and congenital cardiac diseases, there were 2 cases of myocardial infarction, 1 case of mitral stenosis and 3 cases of corrected transportation of great vessels. The others were 3 cases of aortic disease and 1 case of pericardial effusion with lymphoma. 2. Myocardial thinning and left ventricular aneurysm were detected in MR images of myocardial infarction. The left atrium was well delineated and enlarged in the case of mitral stenosis. And segmental analysis was possible in the cases of corrected transposition since all cardiac structures were well delineated anatomically. 3. In aortic diseases, the findings of MR image were enlarged lumen, compressed cardiac chambers in ascending aortic aneurysm, intimal flap, enhanced false lumen in dissecting aneurysm and irregular narrowing of aorta with arterial obstruction in Takayasu's arteritis. 4. Pericardial effusion revealed a conspicuous contrast with neighboring mediastinal fat and cardiac wall due to it low signal encircling cardiac wall. 5. ECG gated MR image is an accurate non-invasive imaging modality for the diagnosis of cardiovascular disease and better results of its clinical application are expected in the future with further development in the imaging system and more clinical experiences

  8. Assessment of hypertrophic cardiomyopathy by ECG gated cardiac computed tomography

    International Nuclear Information System (INIS)

    Takeuchi, Kazuhide; Tanaka, Chujiro; Oku, Hisao

    1981-01-01

    The applicability of ECG gated cardiac computed tomography (CT) in 12 patients with hypertrophic cardiomyopathy was examined. Six of the 12 patients had hypertrophic obstructive cardiomyopathy, including one patient with mid-ventricular obstruction. Three of the 12 patients had hypertrophic non-obstructive cardiomyopathy, and three had apical hypertrophic cardiomyopathy. The diagnosis of hypertrophic cardiomyopathy was confirmed by the angiocardiogram in all patients. Cardiac CT was performed after intravenous administration of contrast media usually given as a bolus injection. The gantry was set with positive 20 0 tilt angle. In all patients with hypertrophic obstructive cardiomyopathy except for mid-ventricular obstruction, the hypertrophied interventricular septum in the basal and mid portions was observed, and the left ventricular cavity was narrowed in systole. In a patient with mid-ventricular obstruction, the marked hypertrophied interventricular septum and antero-lateral papillary muscle were observed. In diastole, the left ventricular cavity was narrow and divided into two parts. The apical cavity was completely disappeared in systole. In all patients with hypertrophic non-obstructive cardiomyopathy, the diffuse hypertrophied interventricular septum was observed in diastole. In systole, the apical portion of the left ventricular cavity was markedly narrow and antero-lateral papillary muscle was hypertrophic. In all patients with apical hypertrophic cardiomyopathy, the marked apical hypertrophy of the left ventricular wall was observed in diastole. It is concluded that ECG gated cardiac CT could estimate myocardial wall motion and thickness and differentiate the types of hypertrophic cardiomyopathy each other. (author)

  9. ECG-gated scintillation probe measurement of left ventricular function

    International Nuclear Information System (INIS)

    Bacharach, S.L.; Green, M.V.; Borer, J.S.; Ostrow, H.G.; Redwood, D.R.; Johnston, G.S.

    1977-01-01

    A nonimaging, ECG-gated scintillation-probe system is described that permits real-time quantification, at high temporal resolution, of the time variation of left ventricular (LV) volume over a complete, average cardiac cycle. Linearity between counting rate and volume, probe positioning, and background correction were investigated for both cylindrically collimated (CC) and parallel-hole-collimated (PC) detectors. In 53 patient studies, results obtained with these probes were compared with results obtained from an ECG-gated gamma camera system (CS) with high temporal resolution. Time-activity curves obtained by all three devices were essentially identical in shape (for CC against CS, r = 0.93; for PC against CS, r = 0.98) and in intracycle timing. Left-ventricular ejection fractions obtained with the probes showed workable agreement with the camera: for CC against CS, r = 0.85 (N = 31); for PC against CS, r = 0.90 (N = 21). When LV background is removed as a source of error, the correlation between (PC) probe and camera is improved (r = 0.95, N = 21). This suggests that the portable probe system be used in circumstances where exact knowledge of LV background is minimally important--e.g., continuous bedside monitoring of changes in LV function

  10. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  11. Correlation study of multislice spiral CT and pathology in relationship between solitary pulmonary nodule and bronchus

    International Nuclear Information System (INIS)

    Qiang Jinwei; Ye Xuanguang; Zhou Kangrong; Jiang Yaping; Wang Qun; Xu Songtao; Tan Lijie

    2003-01-01

    Objective: To investigate the relationship between solitary pulmonary nodule (SPN) and bronchus and its value in predicting the nature of nodule. Methods: Continuous volume targeted scans of 0.5 mm collimation were prospectively performed with multislice spiral CT (MSCT) and reconstructed images of MPR, CPR, and SSD in workstation in 75 patients of SPN with ≤3 cm in diameter were acquired. The emphasis was paid on the manifestation of the shapes and patterns of SPN with related bronchi. The results were correlated with macroscopic and microscopic specimens. Results: (1) The SPN-bronchus relationship was shown very clearly in all patients by the designed protocol. CT demonstrated the relations between SPN and bronchus in 44 (86.3%) malignant and 16 (66.7%) benign nodules. There was no statistically significant difference (P=0.065). (2) Five types of SPN-bronchus relationship were identified with MSCT. Type I: bronchus was obstructed abruptly by the SPN, type II: bronchus penetrated into SPN with tapered narrow and interruption, type III: bronchus lumen shown within SPN was patent and intact, type IV: bronchus ran at the periphery of SPN with intact lumen, and type V: bronchus was displaced, compressed, and narrowed by SPN. (3) With respect to the nature of SPN, malignant nodule most commonly showed type I, secondly type IV, and rarely type V. Benign nodule most often showed type V, secondly type I, and no type II. With respect to the pattern, type I, II, and IV patterns were more commonly seen in malignant nodule, whereas type V pattern was seen frequently in benign nodule. Type III pattern was slightly more common in benign cases. Conclusion: Spiral targeted scan of ultra-thin section with MSCT and followed by MPR, CPR, and SSD reconstruction can greatly improve the manifestation of the bronchioles and accurately demonstrate the patterns of SPN-bronchus relationship. Varied patterns are corresponding to certain nodule and reflect definite pathologic changes

  12. Multislice spiral computed tomography to determine the effects of a recruitment maneuver in experimental lung injury

    Energy Technology Data Exchange (ETDEWEB)

    Henzler, Dietrich; Rossaint, Rolf [University Hospital, RWTH Aachen, Anesthesiology Department, Aachen (Germany); Mahnken, Andreas H.; Wildberger, Joachim E.; Guenther, Rolf W. [University Hospital of the RWTH Aachen, Clinic of Diagnostic Radiology, Aachen (Germany); Kuhlen, Ralf [University Hospital of the RWTH Aachen, Operative Intensive Care Department, Aachen (Germany)

    2006-06-15

    Although recruitment of atelectatic lung is a common aim in acute respiratory distress syndrome (ARDS), the effects of a recruitment maneuver have not been assessed quantitatively. By multislice spiral CT (MSCT), we analyzed the changes in lung volumes calculated from the changes in the CT values of hyperinflated (V{sub HYP}), normally (V{sub NORM}), poorly (V{sub POOR}) and nonaerated (V{sub NON}) lung in eight mechanically ventilated pigs with saline lavage-induced acute lung injury before and after a recruitment maneuver. This was compared to single slice analysis near the diaphragm. The increase in aerated lung was mainly for V{sub POOR} and the less in V{sub NORM}. Total lung volume and intrathoracic gas increased. No differences were found for tidal volumes measured by spirometry or determined by CT. The inspiratory-expiratory volume differences were not different after the recruitment maneuver in V{sub NON} (from 62{+-}18 ml to 43{+-}26 ml, P=0.114), and in V{sub NORM} (from 216{+-}51 ml to 251{+-}37 ml, P=0.102). Single slice analysis significantly underestimated the increase in normally and poorly aerated lung. Quantitative analysis of lung volumes by whole lung MSCT revealed the increase of poorly aerated lung as the main mechanism of a standard recruitment maneuver. MSCT can provide additional information as compared to single slice CT. (orig.)

  13. Multislice spiral computed tomography to determine the effects of a recruitment maneuver in experimental lung injury

    International Nuclear Information System (INIS)

    Henzler, Dietrich; Rossaint, Rolf; Mahnken, Andreas H.; Wildberger, Joachim E.; Guenther, Rolf W.; Kuhlen, Ralf

    2006-01-01

    Although recruitment of atelectatic lung is a common aim in acute respiratory distress syndrome (ARDS), the effects of a recruitment maneuver have not been assessed quantitatively. By multislice spiral CT (MSCT), we analyzed the changes in lung volumes calculated from the changes in the CT values of hyperinflated (V HYP ), normally (V NORM ), poorly (V POOR ) and nonaerated (V NON ) lung in eight mechanically ventilated pigs with saline lavage-induced acute lung injury before and after a recruitment maneuver. This was compared to single slice analysis near the diaphragm. The increase in aerated lung was mainly for V POOR and the less in V NORM . Total lung volume and intrathoracic gas increased. No differences were found for tidal volumes measured by spirometry or determined by CT. The inspiratory-expiratory volume differences were not different after the recruitment maneuver in V NON (from 62±18 ml to 43±26 ml, P=0.114), and in V NORM (from 216±51 ml to 251±37 ml, P=0.102). Single slice analysis significantly underestimated the increase in normally and poorly aerated lung. Quantitative analysis of lung volumes by whole lung MSCT revealed the increase of poorly aerated lung as the main mechanism of a standard recruitment maneuver. MSCT can provide additional information as compared to single slice CT. (orig.)

  14. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  15. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  16. Measurement and analysis of cardiopulmonary vascular in Lanzhou healthy adults with multislice spiral CT

    International Nuclear Information System (INIS)

    Shi Xiaonan; Guo Shunlin

    2013-01-01

    Objective: To constitute a normal standard of cardiopulmonary vascular diameter and size of normal adult in Lanzhou, and to compared with the other's data reported in the previous bibliography by measuring diameter and area of cardiopulmonary artery lumen of the healthy adults in Lanzhou with multislice spiral CT (MSCT). Methods: Three hundred Lanzhou adults with no cardiopulmonary disease were equally assigned to 3 groups according to their age (A group: 18-39 years, B group: 40-60 years, C group: 61-80 years; 50 females and 50 males in each group). CT data were acquired at the end of deep inspiration phase and measurements were done on 3D reconstruction image with precise landmarks. All the results were statistically analyzed. Results: The diameters and areas of the main pulmonary artery left pulmonary artery right pulmonary artery ascending aorta and descending aorta differed significantly among the 3 groups (P<0.05). In groups B and C, there were significant differences in diameters and areas of pulmonary artery left pulmonary artery and right pulmonary between different genders (P<0.05). Conclusion: Imaging standard is provided for Lanzhou adult in early diagnosis of cardiopulmonary disease. The diameters and areas of main pulmonary artery left pulmonary artery and right pulmonary artery of Lanzhou healthy adults are different from that of other regions. It may be related to the geographical environment and the state of air pollution in Lanzhou. (authors)

  17. Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

    International Nuclear Information System (INIS)

    Greess, H.; Lutze, J.; Noemayr, A.; Bautz, W.; Wolf, H.; Hothorn, T.; Kalender, W.A.

    2004-01-01

    The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as ''very good,'' ''good,'' ''diagnostic'' and ''poor'' in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient's geometry and weight. (orig.)

  18. Assessment of hemodynamics in a rat model of liver cirrhosis with precancerous lesions using multislice spiral CT perfusion imaging.

    Science.gov (United States)

    Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng

    2013-01-01

    To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.

  19. Evaluation of the nutcracker syndrome using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Fan Yanqing; Han Ping; Zhou Chengkai; Zhao Long; Wu Hongying; Yu Qun; Liu Yonghua

    2007-01-01

    Objective: To evaluate the ability of multi-slice spiral CT (MSCT) in diagnosing nutcracker syndrome(NCS). Methods: MSCT angiography (MSCTA) or contrast enhanced CT data of 16 patients clinically diagnosed as NCS( patient group) and 80 subjects with nomal kidneys and renal vessels (control group ) were retrospectively reviewed. The anatomy, course and relationship to the adjacent structure of left renal vein (LRV) and its branches were observed. The angle (a) between SMA and the abdominal aorta (AA), the distance (d) between SMA and AA at the level of LRV passing through, the cross areas of LRV through the angle (s1) and at the largest diameter near the renal hilar (s2) were measured and the ratio(q) of s2 to sl was calculated. Results: All LRVs were compressed and showed dilated, 7 of them with the genesial gland vein enlargement. The causes of the LRV narrowing and obstruction were small angle (a) in 14 patients and abnormal path of LRV posterior to AA in 2 cases. The value of a,d,s1,s2 and q in the patient group and the control group were: (21±4) degree, (0.53±0.11) cm, (0.28±0.06) cm 2 , (1.42±0.48) cm 2 , 5.26 and (52±24) degree, (1.39±0.70) cm, (0.81±0.32) cm 2 , (1.21±0.35) cm 2 , 1.52, respectively. The differences were significant between the two groups (P< 0.05). Conclusion: The appearance and its path of the LRV could be well delineated on the MSCT, allowing a accurate evaluation of the LRV narrowing non-invasively. (authors)

  20. The value of multislice spiral CT in transcatheter arterial chemoembolization of the hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Li Zhigang; Zhao Junjing; Shi Gaofeng; Li Shunzong; Han Pengyin; Yang Guang; Liang Guoqing; Wang Hongguang; Huang Jingxiang

    2006-01-01

    Objective: To evaluate the value of multislice spiral CT (MSCT) in transcatheter arterial chemoembolization of the hepatocellular carcinoma. Methods: MSCT were performed in 54 cases of HCC before interventional procedure. CT findings of hepatic artery phase, portal venous phase and hepatic venous phase were observed respectively. CTA were done in 12 cases, the anatomy of celiac artery and its branches were observed. The schemes of interventional therapy were worked out according to the findings of MSCT. The demonstration of lesions and its complications were compared between CT and DSA. Reconstruction of celiac artery branches used the technique of VRT, MIP or MPR. Results: MSCT showed 225 lesions, 10 cases tumor thrombosis of portal vein, 1 case hepatic arteriovenous shunt, and 13 cases hepatic arterioportal shunt. Positive rate of MSCT in showing number of tumor lesions, tumor thrombosis in portal vein was slightly higher than that of DSA, but there was no significant difference (P>0.05). Showing of 3D reconstruction of celiac artery branches in CTA is better than that in DSA, Showing of angles between celiac artery and abdominal aorta in MSCT is more convenient than that in DSA. MSCT showed 5 cases hepatic artery original abnormality. The results were in accord with that in DSA. Five cases were demonstrated of multiple supply blood vessels of tumor in MSCT, It was slightly lower than that of DSA. Conclusion: MSCT is of importance for guidance of transcatheter arterial chemoembolization of the hepatocellular carcinoma, delay time of CT scan is the key to the showing of lesions and blood vessels. (authors)

  1. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  2. Congenital intrahepatic arterioportal and portosystemic venous fistulae with jejunal arteriovenous malformation depicted on multislice spiral CT

    International Nuclear Information System (INIS)

    Chae, Eun Jin; Goo, Hyun Woo; Yoon, Chong Hyun; Kim, Seong-Chul

    2004-01-01

    We report a symptomatic infant with very rare congenital arterioportal and portosystemic venous fistulae in the liver. Multislice CT after partial transcatheter embolisation revealed not only the complicated vascular architecture of the lesion, but also an incidental jejunal arteriovenous malformation which explained the patient's melena. The patient underwent ligation of the hepatic artery and resection of the jejunal arteriovenous malformation. Postoperative multislice CT clearly demonstrated the success of the treatment. (orig.)

  3. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Bastarrika, Gorka [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Cardiac Imaging Unit, Clinica Univ. de Navarra, Pamplona (Spain)], e-mail: bastarrika@unav.es

    2012-06-15

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 {+-} 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 {+-} 58.3 mL) with respect to ECG-gated CT (142.7 {+-} 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 {+-} 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.

  4. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria; Bastarrika, Gorka

    2012-01-01

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 ± 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 ± 58.3 mL) with respect to ECG-gated CT (142.7 ± 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 ± 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols

  5. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun

    2005-01-01

    There is little information on the ability of non-ECG-gated cardiac CT to demonstrate the coronary arteries of children. To evaluate the visibility of the origin and proximal course of coronary arteries on non-ECG-gated cardiac CT, in which the coronary artery was not of primary diagnostic concern, in children with congenital heart disease. From December 2002 to March 2004, 126 cardiac CT examinations from 104 children (median age 11 months; age range 1 day to 15 years) were evaluated. All patients had ventriculo-arterial concordance and no malformations of the great arteries; those with coronary artery anomalies were excluded. Contrast-enhanced 16-slice spiral CT was performed without ECG-gating and multiplanar images for coronary arteries were obtained. The visibility of coronary artery origins was graded on a three-point scale, while nine segments of the arteries were graded on a four-point scale. CT images in which it was possible to trace the coronary arteries were considered diagnostic. The visibility of each whole coronary artery and the origins and proximal four segments of coronary arteries were calculated. The visibility of coronary arteries was also correlated with patient age. The percentage of CT images of diagnostic quality was 49.3% for the whole coronary artery and 81.7% for the origins and proximal four segments. There was a significant positive correlation between the visibility of coronary arteries and age. Non-ECG-gated cardiac CT, in which the coronary artery is not of primary diagnostic concern, is frequently able to visualize the origin and proximal course of coronary arteries and may be helpful in detecting coronary artery anomalies in children with congenital heart disease. (orig.)

  6. The value of multi-slice spiral CT in the preoperative assessment of living renal donor

    International Nuclear Information System (INIS)

    Li Qinghai; Yan Fuhua; Xu Pengju; Zhou Meiling; Zhu Tongyu; Xu Ming; Wang Guomin

    2008-01-01

    Objective: The purpose of this study is to assess the value of multi-slice spiral CT (MSCT) in the preoperative evaluation of living renal donor as a all in one modality. Methods: Thirty-six potential living renal donors underwent the examination using a GE light VCT scanner. Informed consent was obtained from all participants. The plain scan, early arterial phase, late arterial phase and excretory phase scans are performed in the former 25 donors (injection rate 5 rolls, total volume 100 mi, tube tension 120 kV). While in the later 11 donors (2 ml/s 40 ml +4 ml/s 60 ml), the scanning protocol included the plain scan ( 100 kV), vascular phase and excretory phase scans (100 kV). The excretory phase data were used in the reconstruction of CT urography in both groups. All images were reviewed by one radiologist and one urologist, and the findings of MSCT were compared with intraoperative findings for 33 donors, to investigate the utilities of MSCT in assessing renal vascularity, urinary tract and lesions of renal parenchyma. When discrepancies are found between the two reviewers, consensus was obtained via discussion. Au data was statiscally processed with SPSS for Windows. Results: MSCT angiography is in accordance with intraoperative findings in demonstrating the anatomy of renal arteries and renal vein trunk, accesary arteries, early branching of renal artery. The findings from CTA are highly in accordance with the intraoperative findings, which facilitate intraoperative ligation and reduce relevant complications. CTU demonstrates the anatomy of urinary, tract in good agreement with the intraoperative findings. The image quality of 3D vascularity and CTU between the two groups, scored 4.4 ± 1.2 vs 4.2 ± 1.3 and 4.6 ± 0.8 vs 4.4 ± 0.9 respectively, no statistical between-groups difference was found (Z=-0.89, -0.47, P>0.05). Conclusion: MSCT multiphase scanning combined with CTA and CTU play a important role in the evaluation of living renal donor, which

  7. The value of multislice spiral CT in the pre-operative diagnosis of cleft palate

    International Nuclear Information System (INIS)

    Tang Guangxi; Sun Lianfen; Zhang Xiaolin; Yu Chengxin; Lu Ji; Wang Xiaopeng; Li Liya; Yang Cheng; Wang Jun; Tian Yiqing

    2004-01-01

    Objective: To evaluate the practical value of multislice spiral CT (MSCT) in the preoperative diagnosis of cleft palate. Methods: Twenty patients with cleft palate were examined by using thin-slice (1.25 mm/4i) axial MSCT scanning and CT virtual endoscope (CTVE) imaging before and after operations. The cleft of each lesion was measured in the primary axial images. Results: Of the 20 cases, soft-and-hard cleft palate (grade II) was detected in 10 cases, with the clefts of soft palate between 1.5 cm and 2.2 cm, and the clefts of soft-and-hard palate between 1.2 cm and 2.0 cm. The right utter cleft palates were found in 3 cases with the clefts of soft palate between 2.0 cm and 2.5 cm, the clefts of soft-and-hard palate between 2.0 cm and 2.4 cm, and the clefts of hard palate between 1.8 cm and 2.2 cm. The left utter cleft palates (grade III) were found in 5 cases with the clefts of soft palate between 1.2 cm and 1.8 cm, the clefts of soft-and-hard palate between 0.9 cm and 2.0 cm, and the clefts of hard palate between 0.9 cm and 1.8 cm. The bilateral utter cleft palates (grade III) were detected in 2 cases with the clefts of soft palate between 2.1 cm and 2.3 cm, the clefts of soft-and-hard palate between 1.8 cm and 2.0 cm, and the clefts of hard palate between 1.9 cm and 2.3 cm. Conclusion: MSCT could excellently display the shape of all lesions before operation, especially the splitting degree of hard cleft palates in the axial images. Accurate measurements could be done for the cleft of different lesions in MSCT images. CTVE could clearly and directly show the shape of the lesion's interior surface. The pre-operative and post-operative images of each case could be perfectly compared by the combination of MSCT and CTVE

  8. ECG gated NMR-CT for cardiovascular diseases

    International Nuclear Information System (INIS)

    Nishikawa, J.; Machida, K.; Iio, M.; Yoshimoto, N.; Sugimoto, T.; Kawaguchi, H.; Mano, H.

    1984-01-01

    The authors applied NMR-CT to cardiac study with ECG gated technique to evaluate the left ventricular (LV) function and compared it with cardiovascular nuclear medicine study (NM). The NMR-CT machine has resistive air-core magnet with 0.15 Tesla. The saturation recovery image or inversion recovery image were obtained as 256 x 256 matrix and 15 mm in thickness. The study population was ten patients who were evaluated both by NMR image and by NM performed within one week interval. The heart muscle was able to be visualized without any contrast material nor radioisotopes in inversion recovery images, whereas saturation recovery images failed to separate heart muscle from blood pool. The wall motions of LV in both methods were well correlated except for inferior wall. The values of ejection fraction in NMR image were moderately low, but two modalities showed satisfactory correlation (r=0.85). The region of myocardial infarction was revealed as wall thinning and/or wall motion abnormality. It is still preliminary to draw a conclusion, however, it can be said that in the evaluation of LV function, method by NMR might be of equal value to those of NM. It can be certain that eventually gated NMR-CT will become more effective method for various aspects of cardiovascular evaluation

  9. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  10. Clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease

    International Nuclear Information System (INIS)

    Tian Xinhua; Liu Jianhua; Gong Tingting; Geng Lili; Sun Yong

    2011-01-01

    Objective: To investigate the clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease, and to evaluate the relationship of the image quality and radiation dose between prospective ECG-gated and retrospective ECG-gated cardiac CT angiography (CTA). Methods: Sixty patients who doubt congenital heart disease underwent cardiac CTA, and they were randomly divided into two groups. Thirty patients in group A underwent prospective ECG-gated cardiac CTA, and thirty patients in group B underwent retrospective ECG-gated cardiac CTA. Then the homogeneous enhancement of vascular structures, stair-step artifact, overall image quality and radiation dose were evaluated. Results: The homogeneous enhancement of vascular structures were 2.8±0.3 and 2.7±0.6, respectively, in two groups; and there was no statistical significance (P>0.05). The stair-step artifact were 3.0±0.9 and 3.1±0.9, respectively, in two groups; and there was also no statistical significance (P>0.05). The overall image quality were 3.0±0.8 and 3.1±0.9, respectively, in two group; and there was statistical significance (P>0.05). However, the effective dose were (5.24±0.52) mSv and (16.68±1.49) mSv, respectively, in two groups; and there was statistical significance (P<0.001). Conclusion: Compared with retrospective ECG-gated cardiac CTA, prospective ECG-gated cardiac CTA can reduce radiation dose about 68.6% , while maintaining the image quality which could be made diagnosis. (authors)

  11. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl [Sahlgrenska University Hospital, Department of Radiology, Gothenburg (Sweden); Perrotta, Sossio [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); Bech-Hanssen, Odd [Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Cardiology, Gothenburg (Sweden); Olaison, Lars [Sahlgrenska University Hospital, Department of Infectious Diseases, Gothenburg (Sweden); Svensson, Gunnar [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); The Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Institute of Medicine, Gothenburg (Sweden)

    2012-11-15

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  12. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    International Nuclear Information System (INIS)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl; Perrotta, Sossio; Bech-Hanssen, Odd; Olaison, Lars; Svensson, Gunnar

    2012-01-01

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  13. Evaluation of retrospectively ECG-gated 4-row multidetector CT in patients planned for minimal invasive coronary artery bypass grafting; Die EKG-getriggerte 4-Zeilen-Spiral-CT des Herzens in der praeoperativen Bildgebung vor minimalinvasiver koronarer Bypass-Operation

    Energy Technology Data Exchange (ETDEWEB)

    Begemann, P.G.C.; Ittrich, H.; Koops, A.; Adam, G.; Weber, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Radiologisches Zentrum, Universitaetsklinikum, Hamburg (Germany); Arnold, M.; Detter, C.; Boehm, D.H.; Reichenspurner, H. [Universitaetsklinikum Hamburg-Eppendorf, Herzzentrum, Herz und Gefaesschirurgie, Hamburg (Germany)

    2005-08-01

    Purpose: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. Material and methods: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4 x 2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4 x 1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), coursek of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. Results: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and

  14. Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results

    International Nuclear Information System (INIS)

    Greess, H.; Bautz, W.; Baum, U.; Wolf, H.; Suess, C.; Kalender, W.A.

    2004-01-01

    Purpose: To investigate the potential of dose reduction in multislice spiral CT (MSCT) with automatic exposure control. Materials and Methods: The study was performed on a Sensation 4 multislice scanner. This prototype implementation analyzed the distribution of the attenuation along the z-axis in the lateral and sagittal directions of the digital radiogram. Depending on this distribution of the attenuation, the tube current (mA) is defined for every tube rotation. In addition, the tube current was modulated during each tube rotation. First, a three step oval water phantom was measured to evaluate the potential of this method with respect to dose reduction and image quality. In a patient study (n=26), four different scan regions (shoulder, thorax, abdomen, pelvis) were examined and dose (mAs) and image quality evaluated in comparison to examinations with a standard protocol for these regions in adults and a weight-adjusted standard protocol in children. The image quality was classified in consensus as good, sufficient and poor image quality. Results: By adapting and modulating the tube current, we substantially reduced the variation of noise in one spiral scan and in one scan region of our patient collective. The dose (average mAs) was reduced by 31% to 66% in children (mean 44%) and between 35% and 64% in adults (mean 53%), depending on the scan region. The image quality was substantially improved in regions with high attenuation and did not suffer in low attenuation regions. Conclusion: The dose can be reduced substantially by an automatic exposure control including angular tube current modulation with the same or improved image quality. (orig.) [de

  15. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  16. Simultaneous multislice magnetic resonance fingerprinting (SMS-MRF) with direct-spiral slice-GRAPPA (ds-SG) reconstruction.

    Science.gov (United States)

    Ye, Huihui; Cauley, Stephen F; Gagoski, Borjan; Bilgic, Berkin; Ma, Dan; Jiang, Yun; Du, Yiping P; Griswold, Mark A; Wald, Lawrence L; Setsompop, Kawin

    2017-05-01

    To develop a reconstruction method to improve SMS-MRF, in which slice acceleration is used in conjunction with highly undersampled in-plane acceleration to speed up MRF acquisition. In this work two methods are employed to efficiently perform the simultaneous multislice magnetic resonance fingerprinting (SMS-MRF) data acquisition and the direct-spiral slice-GRAPPA (ds-SG) reconstruction. First, the lengthy training data acquisition is shortened by employing the through-time/through-k-space approach, in which similar k-space locations within and across spiral interleaves are grouped and are associated with a single set of kernel. Second, inversion recovery preparation (IR prepped), variable flip angle (FA), and repetition time (TR) are used for the acquisition of the training data, to increase signal variation and to improve the conditioning of the kernel fitting. The grouping of k-space locations enables a large reduction in the number of kernels required, and the IR-prepped training data with variable FA and TR provide improved ds-SG kernels and reconstruction performance. With direct-spiral slice-GRAPPA, tissue parameter maps comparable to that of conventional MRF were obtained at multiband (MB) = 3 acceleration using t-blipped SMS-MRF acquisition with 32-channel head coil at 3 Tesla (T). The proposed reconstruction scheme allows MB = 3 accelerated SMS-MRF imaging with high-quality T 1 , T 2 , and off-resonance maps, and can be used to significantly shorten MRF acquisition and aid in its adoption in neuro-scientific and clinical settings. Magn Reson Med 77:1966-1974, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  18. Subtraction imaging of the ECG gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Tanegashima, K.; Fukui, M.; Hyodo, H.

    1987-05-01

    The subtracting manipulation of contrast-enhanced gated cardiac CT (GCCT) images was experimentally studied with TCT 60A - 30 type (Toshiba) for clinical use, thereby reducing the amount of contrast medium (CM). Initially the optimum relationship between the concentration of CM and its injected velocity was determined using the model of resected canine hearts and in actual dogs. The emphasized good-subtracted images were obtained when the difference of CT values was approximately 40 H.U. between cardiac cavity and myocardium. Such condition was feasible in the use of 25 % Diatrizoic acid and its injected velocity of 0.02 ml/kg/sec. Finally the reduction of the amount of CM by 1/3 became possible in clinical settings. The method is applicable to multi-slice GCCT in various heart diseases.

  19. Absolute quantitation of left ventricular wall and cavity parameters using ECG-gated PET

    DEFF Research Database (Denmark)

    Freiberg, Jacob; Hove, Jens D; Kofoed, Klaus F

    2004-01-01

    in a heart phantom and in healthy subjects. Twelve healthy men aged 64 +/- 8 years were studied by use of cine magnetic resonance imaging (MRI) and ECG-gated FDG-PET during euglycemic glucose-insulin clamp. At increasing image noise levels, the estimated cavity volume of the heart phantom was within 2 m...

  20. Accuracy of 16-detector Multislice Spiral Computed Tomography in the initial evaluation of dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Cornily, Jean-Christophe; Gilard, Martine; Le Gal, Gregoire; Pennec, Pierre-Yves; Vinsonneau, Ulric; Blanc, Jean-Jacques; Mansourati, Jacques; Boschat, Jacques

    2007-01-01

    Background: Multislice Computed Tomography (MSCT) recently proved its accuracy in the detection of coronary artery disease (CAD). It can also give information about left ventricular function and venous network anatomy. We here sought to validate a MSCT-based strategy in the initial evaluation of patients with dilated cardiomyopathy (DCM). Methods: 36 patients with DCM underwent cardiac MSCT before conventional coronary angiography with ventriculography. We analysed arterial calcium score (Agatston score equivalent: ASE), coronary stenosis, left ventricular parameters and venous network. Results: The sensitivity of a MSCT-based strategy in detecting significant CAD was 100% and the specificity 80%. The positive and negative predictive values were respectively 67% and 100%. For ASE 1.000, conventional coronary angiography is mandatory due to MSCT's poor interest in such cases; when ASE <1.000, a contrast-enhanced MSCT may, when normal, replace coronary angiography

  1. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  2. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  3. To evaluate vascular complications of transplant kidney examined by multislice spiral CT angiograph

    International Nuclear Information System (INIS)

    Peng Qian; Fan Miao; Luo Xiaomei

    2008-01-01

    Objective: To evaluate the value of multislice CT angiography (MSCTA) in vascular complications of transplant kidney. Methods: Six transplant kidneys were undergone enhanced MSCT scanning postoperation. MPR, CPR, VR and VP reformation were performed to observe transplant kidney's parenchyma, renal artery, and renal vein. To analysis all the reconstruction technique and find the advantage and shortage of them. Results: One case showed enhanced function of transplant kidney decreased. Vascular stenosis was found in one case and false aneurysm was found in another transplant kidney. Transplant kidney were enhanced normal in the left three cases. MPR couldn't reconstruct all the tortuous vessel of renal hilus in one plane. But all six cases could expose the vessel of renal hilus very clearly in coronal section and sagittal plane of CPR. Six cases of VR could observe the vessel direction and lesions outside vessel through rotate the reconstruction image. VP could see through inside the vessel of transplant kidney. Conclusion: MSCTA has an important role as an imaging technique to evaluate vascular complications of transplant kidney, it can replace DSA. (authors)

  4. Step-and-shoot prospectively ECG-gated vs. retrospectively ECG-gated with tube current modulation coronary CT angiography using 128-slice MDCT patients with chest pain: diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Kim, Jeong Su; Choo, Ki Seok; Jeong, Dong Wook

    2011-01-01

    Background With increasing awareness for radiation exposure, the study of diagnostic accuracy of coronary CT angiography (CCTA) with low radiation dose techniques is mandatory to both radiologist and clinician. Purpose To compare diagnostic performance and effective radiation dose between step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with tube current modulation (TCM) CCTA using 128-slice multidetector computed tomography (MDCT). Material and Methods We retrospectively evaluated 60 patients who underwent CCTA with either of two different low-dose techniques using 128-slice MDCT (23 patients for step-and shoot-prospectively ECG-gated and 37 patients for retrospectively ECG-gated with TCM CCTA) followed by conventional coronary angiography. All coronary arteries and all segments thereof, except anatomical variants or small size (< 1.5 mm) ones, were included in analysis. Results In per-segment analysis, sensitivity, specificity, positive predictive value, and negative predictive value were 91/96%, 95/94%, 75/73%, and 98/99% for step-and-shoot prospectively ECG-gated and retrospectively ECG gated with TCM CCTA, respectively, relative to conventional coronary angiography. Effective radiation dose were 1.75 ± 0.83 mSv, 4.91 ± 1.71 mSv in the step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with TCM CCTA groups, respectively. Conclusion The two low-radiation dose CCTA techniques using 128-slice MDCT yields comparable diagnostic performance for coronary artery disease in symptomatic patients with low heart rates

  5. Diagnostic accuracy of prospective ECG gated coronary computed tomography on a 256 slices scanner: Daily practice experience

    Directory of Open Access Journals (Sweden)

    Ahmed M. Fareed

    2014-03-01

    Conclusions: In a highly prevalence diseased population, prospective ECG-gated CTCA using 256-slice scanner is highly accurate for detection and quantification of the degree of coronary luminal stenosis in comparison to ICA.

  6. Clinical application of multislice spiral CT angiography in evaluation of anomalous vertebral artery

    International Nuclear Information System (INIS)

    Hua Rui; Liu Jun; Zhang Yu

    2008-01-01

    Objective: To evaluate the diagnostic value of 16-slice spiral computed tomography angiography (MSCTA) in evaluation of anomalous vertebral artery. Methods: MSCTA data from 32 patients with anomalous vertebral artery were retrospectively analyzed. Results: 22 cases had vertebral artery course variation (bended into the C 5 , C 4 or C 3 foramen transversarium), 7 cases had variation in the prevertebral segments of vertebral arteries, 15 patients had unilateral vertebral congenital stenosis, 1 case had double vertebral artery branch, 1 case had vertebral arterial fenestration, and 2 cases had vertebral artery in one side that did not converged upon basilar artery and unilateral vertebral artery formed basilar artery. Conclusion: MSCTA is a useful noninvasive imaging tool for the diagnosis of vertebral artery variations. (authors)

  7. Diagnosis of bronchiectasis with multislice spiral CT: accuracy of 3-mm-thick structured sections

    Energy Technology Data Exchange (ETDEWEB)

    Remy-Jardin, Martine; Amara, Assia; Campistron, Philippe; Mastora, Ioana; Remy, Jacques [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France); Delannoy, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France)

    2003-05-01

    The aim of this study was to evaluate the accuracy of 3-mm-thick reconstructed sections in the diagnosis of bronchiectasis with multislice CT (MSCT). Forty consecutive patients suspected of bronchiectasis (23 females, 17 males; mean age 51 years) underwent MSCT of the entire thorax with a 4 x 1-mm collimation (120 kV, 0.5 s/rotation, 80 mAs/slice) and a pitch of 1.75. From each data set (mean z-axis coverage: 257 mm; mean duration: 21 s), two series of images were systematically generated: 1-mm (group 1) and 3-mm (group 2)-thick reconstructed scans. Both series of images were obtained at 10-mm intervals and reconstructed with a high-spatial-frequency algorithm. Two observers independently analyzed the presence of bronchiectasis and associated abnormalities in group-1 and group-2 lung images. No significant difference between group 1 and group 2 was found in: (a) the detection of bronchiectasis, identified in 24 patients (60%) in group 1 and in 23 patients (57.5%) in group 2 (p=0.08); (b) the evaluation of the extent of bronchiectasis, identifying focal bronchiectasis in 10 patients (25%) in group 1 and 7 patients (17.5%) in group 2 (p=0.39) and multifocal bronchiectasis in 16 patients (40%) in both groups; (c) the characterisation of bronchiectasis (cylindral bronchiectasis: group 1, n=24, 60%; group 2, n=21, 53%, p=0.08); varicose bronchiectasis: group 1, n=5, 12.5%; group 2, n=6, 15%, p=0.56; and cystic bronchiectasis: group 1, n=2, 5%; group 2, n=2, 5%. Apart from the identification of abnormal bronchial wall thickening (group 2, n=35, 87.5%, vs group 1, n=31, 77.5%, p<0.05), recognition of associated bronchopulmonary anomalies did not differ between the two groups. This study demonstrates a comparable accuracy of the 3- and 1-mm-thick reconstructed scans in the detection and characterization of bronchiectasis. These results suggest the potential usefulness of 3-mm-thick scans generated from 4 x 2.5-mm acquisitions in the screening of bronchiectasis, which would

  8. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  9. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  10. Preliminary feasibility assessment on the investigation of bronchogenic adenocarcinoma angiogenesis with dynamic multi-slice spiral computed tomography

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Li Huimin; Liu Shiyuan; Li Chengzhou; Zhang Chenshi; Tao Zhiwei

    2003-01-01

    Objective: To evaluate the feasibility on the investigation of bronchogenic adenocarcinoma angiogenesis with dynamic multi-slice spiral computed tomography (MSCT) . Methods: 27 patients with bronchogenic adenocarcinomas (diameter ≤4 cm) underwent multi-location dynamic contrast material-enhanced (90 ml, 4 ml/s) serial CT. These dynamic images were processed with the 'time lapse' software and the 'functional CT' software. Peak heights of bronchogenic adenocarcinoma and the aorta, perfusion and mean transit time (MTT) were measured. Ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta was calculated. Perfusion and mean transit time images were obtained. Results: Peak height of bronchogenic adenocarcinoma was (36.66 ± 13.53) HU. No statistically significant difference in the peak height was found between our results and the results of Ukihide et al (mean peak height 34.1 HU) (t =0.981, P = 0.335). Bronchogenic adenocarcinoma-to-aorta ratio was (15.72±4.66 )%. The difference in bronchogenic adenocarcinoma -to-aorta ratio between our results and the results of Zhang and Kono (mean malignant SPN-to-aorta ratio 14.6%) did not reach statistical significance (t=1.244, P=0.225). The mean perfusion value (3.278 ml·min - · kg -1 ) was in the range of that (1.36-2.98 ml·min -1 ·kg -1 ) measured with a single photon emission CT (SPECT). Mean transit time was (17.60 ± 4.52) s. Conclusion: It is feasible to investigate bronchogenic adenocarcinoma angiogenesis with dynamic MSCT

  11. Evaluation of coronary artery disease by helical CT using retrospective ECG-gating

    International Nuclear Information System (INIS)

    Kawawa, Yoko

    2001-01-01

    The purpose of this study is to evaluate the usefulness of helical CT using retrospective ECG-gating for visualization of the coronary artery and detection of coronary artery disease. We performed a coronary artery phantom study and established this new application, with 1-mm collimation, 1-mm table increment, and 0.1-mm reconstruction (0.8 sec/rotation). Helical CT of 31 patients with 39 coronary artery diseases (34 coronary artery stenoses, 1 vasospastic angina, 1 coronary artery dissection, 1 coronary artery ectasia and 2 coronary artery aneurysms) was performed in a single breath hold and ECG-gating without and with intravenous injection of nonionic iodine contrast material. We selected the images which were not affected by cardiac motion from the reconstruction images, in order to visualize the coronary artery for detection of coronary artery disease. The coronary artery was well visualized in 32 out of 39 vessels (82%). A good visualization of the coronary artery was correlated with the heart rate. Further, in this well visualized group, coronary artery diseases were detected in 24 out of 31 cases (77%). One case of vasospastic angina was not included. It was difficult to detect coronary artery disease in cases of heavily calcified vessels or in the left circumflex artery. Helical CT using this retrospective ECG-gating is a useful noninvasive examination for evaluation of coronary artery disease. (author)

  12. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    International Nuclear Information System (INIS)

    Schwemmer, C; Müller, K; Hornegger, J; Rohkohl, C; Lauritsch, G

    2013-01-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D–2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average. (paper)

  13. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    Science.gov (United States)

    Schwemmer, C.; Rohkohl, C.; Lauritsch, G.; Müller, K.; Hornegger, J.

    2013-06-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D-2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average.

  14. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  15. Value of multi-slice spiral CT in diagnosis the detection of fish bone impaction in the esophagus

    International Nuclear Information System (INIS)

    Luo Min; Hu Daoyu; Wang Qiuxia; Pei Yigang

    2009-01-01

    Objective: To investigate the detection rate and diagnostic value of multi-slice spiral CT scan in detecting fish bone impaction in the esophagus. Methods: Experimental group: 30 fresh water fish bones from three variety classes were divided into three groups with length of (23.36±0.15), (28.51± 0.07) and (30.89±0.10) mm, and diameter of (4.49±0.31), (1.78±0.09) and (0.49±0.07) mm. The fish bones were put into esophagus models in three different types including parallel, perpendicular and oblique. MSCT with axial scan combined with three dimensional reconstruction technique and plain X-ray film ( CR and DR) were used to examine the model. The relations of the number and rate of fish bones were compared between MSCT and X-ray film. Clinical group: MSCT imaging were performed in 20 cases proved by esophageal endoscope or clinical operation, among which 11 cases received plain X-ray film (CR and DR), 15 cases received Barium-soaked cotton and 17 cases received endoscope. Paired Chi-square test was used to compare the differences of detection of fishbone by the different ways. Results: In experimental group: All the 90 cases (100%) fish bones of three different species were clearly revealed on MSCT image; only 60 cases (66.7%) fish bones were revealed by plain X-ray film (CR and DR). The number and rate of fish bones detected by MSCT was higher than that of plain X-ray film (CR and DR) (χ 2 =28.03, P 2 =7.11, P 2 =4.17, P<0.05). Conclusions: The sensitivity and detection rate of fish bone with MSCT was high and could evaluate the surrounding and complications of the esophagus. MSCT could be used as the first examination of impacted fish bones in the esophagus. (authors)

  16. Substantial dose reduction in modern multi-slice spiral computed tomography (MSCT)-guided craniofacial and skull base surgery

    International Nuclear Information System (INIS)

    Widmann, G.; Fasser, M.; Jaschke, W.; Bale, R.; Schullian, P.; Zangerl, A.; Puelacher, W.; Kral, F.; Riechelmann, H.

    2012-01-01

    Purpose: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). Materials and Methods: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120 kV/100 mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100 kV/35ref. mAs, (LD-II) 80 kV/40 - 41ref. mAs, and (LD-III) 80 kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). Results: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1,62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt fuer Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. Conclusion: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery. (orig.)

  17. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  18. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  19. Experimental and clinical analyses of optimum Fourier filtering in ECG-gated blood pool scintigraphy

    International Nuclear Information System (INIS)

    Shimabukuro, Kunisada

    1988-01-01

    A phantom study was undertaken to determine the optimum order harmonics in Fourier analysis for volume curves obtained by ECG-gated blood pool scintigraphy. The volume curve obtained by Tc-99m scintigraphy was computed by the 1st through 10th order harmonics of Fourier transform. The shape of each volume curve fitted by Fourier transform was compared with the shape of the generated ideal curve. Curves fitted with the 3rd or more order harmonics were approximate to the ideal curve in shape during the systolic phase. The 6th to 10th order harmonics were suitable for the early diastole phase. As determined by peak ejection rate and peak filling rate (PFR), the 6th order harmonics was superior to the 3rd order harmonics in evaluating early diastolic abnormalities. In the clinical settings, there was no difference between the 3rd and 6th order harmonics in evaluating systolic abnormalities; however, the 6th order harmonics was more sensitive than the 3rd order harmonics in evaluating early diastolic abnormalities. The 6th order harmonics significantly reflected PFR in the group of hypertrophic cardiomyopathy (n=10) and time to PFR in the groups of old myocardial infarction (n=10) and angina pectoris (n=10). In conclusion, the 6th to 9th order harmonics of Fourier analysis may be useful in analyzing both systolic and early diastolic phases inf left ventricular volume curves obtained from ECG-gated cardiac blood pool scintigraphy. (Namekawa, K)

  20. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul, E-mail: paul.stolzmann@usz.ch [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetti, Robert; Baumueller, Stephan [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Plass, Andre; Falk, Volkmar [Clinic for Cardiovascular Surgery, University Hospital Zurich (Switzerland); Scheffel, Hans; Feuchtner, Gudrun; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Alkadhi, Hatem [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Leschka, Sebastian [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2011-07-15

    Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates {<=}70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 {+-} 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 {+-} 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates {<=}70 bpm

  1. Blood flow patterns of solitary pulmonary nodules with enhancement: clinical value of multi-slice spiral CT

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Liu Huimin; Li Yuli; Li Huimin; Li Chengzhou; Zhang Chenshi; Tao Zhiwei; Yang Chunshan; Jiang Qingjun; Ouyang Lin; Yu Hong

    2004-01-01

    Objective: To evaluate the efficacy of dynamic multi-slice spiral computed tomography (MSCT) for providing quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs) and the correlation of vascular endothelial growth factor (VEGF)-positive tumor angiogenesis and the quantifiable parameters of blood flow pattern in solitary bronchogenic adenocarcinoma. Methods Seventy-eight patients with SPNs (with strong enhancement) (diameter ≤4 cm; 68 malignant; 10 active inflammatory) underwent multi-location dynamic contrast enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4 ml/s by using an autoinjector) serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion, peak height, and ratio of peak height of the SPN to that of the aorta were calculated. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. The quantifiable parameters (perfusion, peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta and mean transit time) of blood flow pattern in 30 VEGF-positive solitary bronchogenic adenocarcinoma were compared with microvessel densities (MVD) and VEGF expression by immunohistochemistry. Results: No statistically significant difference in the peak height was found between malignant (35.79 ± 10.76) HU and active inflammatory (39.76 ± 4.59) HU nodules (t=1.148, P=0.255). SPN-to-aorta ratio (14.27 ± 4.37)% and perfusion value (3.02 ± 0.96)ml -1 ·min -1 ·kg -1 in malignant SPNs were significantly lower than those of active inflammatory nodules(18.51 ± 2.71)%, (6.34 ± 4.39)ml -1 ·min -1 ·kg -1 (t=2.978, P=0.004, t=5.590, P -1 ·min -1 ·kg -1 , mean transit time (14.86 ± 5.84) s, and MVD (70.15 ± 20.03). Each of peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta, and perfusion correlated positively with MVD (r=0.781, P<0.0001; r=0

  2. An evaluation of the ECG gated cardiac CT on old myocardial infarction

    International Nuclear Information System (INIS)

    Tanegashima, Kazuhiro; Tejima, Yasuaki; Nakasone, Noriyo; Hyodo, Haruo

    1984-01-01

    In order to examine the accuracy of ECG gated cardiac CT (G-CCT), G-CCT findings were compared with ECG and cardiac echographic findings in 25 cases of old myocardial infarction. From the detection rate according to the infarct area, abnormal findings in the anterior wall and the septum obtained from G-CCT were in good accordance with those from ECG. Although all of the G-CCT findings did not agree with those of cardiac echography in cases in which abnormal findings were seen in multiple areas, the detection rate of cardiac abnormal findings as a whole by G-CCT was the same as that by cardiac echography. (Namekawa K.)

  3. Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients

    International Nuclear Information System (INIS)

    D'Agostino, A.G.; Remy-Jardin, M.; Khalil, C.; Remy, J.; Delannoy-Deken, V.; Duhamel, A.; Flohr, T.

    2006-01-01

    The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient's size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [±standard deviation (SD)] body mass index (BMI) of 24.47 (±4.64); (b) a mean (±SD) heart rate of 72.04 (±15.76) bpm; (c) a mean (±SD) scanning time of 18.3 (±2.73) s; (d) a mean (±SD) dose-length product (DLP) value of 260.57 (±83.67) mGy/cm; (e) an estimated average effective dose of 4.95 (±1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of interpolation artefacts

  4. ECG-gated interventional cardiac reconstruction for non-periodic motion.

    Science.gov (United States)

    Rohkohl, Christopher; Lauritsch, Günter; Biller, Lisa; Hornegger, Joachim

    2010-01-01

    The 3-D reconstruction of cardiac vasculature using C-arm CT is an active and challenging field of research. In interventional environments patients often do have arrhythmic heart signals or cannot hold breath during the complete data acquisition. This important group of patients cannot be reconstructed with current approaches that do strongly depend on a high degree of cardiac motion periodicity for working properly. In a last year's MICCAI contribution a first algorithm was presented that is able to estimate non-periodic 4-D motion patterns. However, to some degree that algorithm still depends on periodicity, as it requires a prior image which is obtained using a simple ECG-gated reconstruction. In this work we aim to provide a solution to this problem by developing a motion compensated ECG-gating algorithm. It is built upon a 4-D time-continuous affine motion model which is capable of compactly describing highly non-periodic motion patterns. A stochastic optimization scheme is derived which minimizes the error between the measured projection data and the forward projection of the motion compensated reconstruction. For evaluation, the algorithm is applied to 5 datasets of the left coronary arteries of patients that have ignored the breath hold command and/or had arrhythmic heart signals during the data acquisition. By applying the developed algorithm the average visibility of the vessel segments could be increased by 27%. The results show that the proposed algorithm provides excellent reconstruction quality in cases where classical approaches fail. The algorithm is highly parallelizable and a clinically feasible runtime of under 4 minutes is achieved using modern graphics card hardware.

  5. Automated Agatston score computation in non-ECG gated CT scans using deep learning

    Science.gov (United States)

    Cano-Espinosa, Carlos; González, Germán.; Washko, George R.; Cazorla, Miguel; San José Estépar, Raúl

    2018-03-01

    Introduction: The Agatston score is a well-established metric of cardiovascular disease related to clinical outcomes. It is computed from CT scans by a) measuring the volume and intensity of the atherosclerotic plaques and b) aggregating such information in an index. Objective: To generate a convolutional neural network that inputs a non-contrast chest CT scan and outputs the Agatston score associated with it directly, without a prior segmentation of Coronary Artery Calcifications (CAC). Materials and methods: We use a database of 5973 non-contrast non-ECG gated chest CT scans where the Agatston score has been manually computed. The heart of each scan is cropped automatically using an object detector. The database is split in 4973 cases for training and 1000 for testing. We train a 3D deep convolutional neural network to regress the Agatston score directly from the extracted hearts. Results: The proposed method yields a Pearson correlation coefficient of r = 0.93; p <= 0.0001 against manual reference standard in the 1000 test cases. It further stratifies correctly 72.6% of the cases with respect to standard risk groups. This compares to more complex state-of-the-art methods based on prior segmentations of the CACs, which achieve r = 0.94 in ECG-gated pulmonary CT. Conclusions: A convolutional neural network can regress the Agatston score from the image of the heart directly, without a prior segmentation of the CACs. This is a new and simpler paradigm in the Agatston score computation that yields similar results to the state-of-the-art literature.

  6. Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography

    International Nuclear Information System (INIS)

    Efstathopoulos, E P; Kelekis, N L; Pantos, I; Brountzos, E; Argentos, S; Grebac, J; Ziaka, D; Seimenis, I; Katritsis, D G

    2009-01-01

    Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 ± 0.6 mSv versus 13.4 ± 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

  7. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  8. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Watzke, Oliver; Kalender, Willi A.

    2001-01-01

    In modern computed tomography (CT) there is a strong desire to reduce patient dose and/or to improve image quality by increasing spatial resolution and decreasing image noise. These are conflicting demands since increasing resolution at a constant noise level or decreasing noise at a constant resolution level implies a higher demand on x-ray power and an increase of patient dose. X-ray tube power is limited due to technical reasons. We therefore developed a generalized multi-dimensional adaptive filtering approach that applies nonlinear filters in up to three dimensions in the raw data domain. This new method differs from approaches in the literature since our nonlinear filters are applied not only in the detector row direction but also in the view and in the z-direction. This true three-dimensional filtering improves the quantum statistics of a measured projection value proportional to the third power of the filter size. Resolution tradeoffs are shared among these three dimensions and thus are considerably smaller as compared to one-dimensional smoothing approaches. Patient data of spiral and sequential single- and multi-slice CT scans as well as simulated spiral cone-beam data were processed to evaluate these new approaches. Image quality was assessed by evaluation of difference images, by measuring the image noise and the noise reduction, and by calculating the image resolution using point spread functions. The use of generalized adaptive filters helps to reduce image noise or, alternatively, patient dose. Image noise structures, typically along the direction of the highest attenuation, are effectively reduced. Noise reduction values of typically 30%-60% can be achieved in noncylindrical body regions like the shoulder. The loss in image resolution remains below 5% for all cases. In addition, the new method has a great potential to reduce metal artifacts, e.g., in the hip region

  9. The role of multislice spiral computed tomography in the diagnosis and management of acute facial trauma in patients with multiple injuries.

    Science.gov (United States)

    Nemsadze, G; Urushadze, O

    2011-11-01

    Using of mutislice spiral CT as first line examination for the diagnosis of Acute Facial trauma in the setting of Polytrauma reduces both: valuable time and cost of patient treatment. After a brief clinical examination, MDCT was performed depending on the area of injury, using a slice thickness of 0.65 mm. The obtained data were analyzed using 3D, MIP and Standard axial with Bone reconstruction protocols. 64 polytrauma patients were evaluated with both Anterior and Lateral craniography (plain skull X ray: AP and Lateral) and Multi Slice CT. Craniography detected only 18 cases of traumatic injuries of facial bones, but exact range of dislocation and accurate management plan could not be established. In the same 64 cases, Multislice CT revealed localization of all existed fractures, range of fragment dislocation, soft tissue damage and status of Paranasal sinus in 62 cases (96.8%). In two cases MS CT missed the facial fracture, in one case the examination was complicated because of bone thinness and numerous fracture fragments, in another multiple foreign body artifacts complicated the investigation. The study results show that, CT investigation based on our MDCT polytrauma protocol, detects all more or less serious facial bone injuries.

  10. Comparison of endoscopic ultrasonography and multislice spiral computed tomography for the preoperative staging of gastric cancer - results of a single institution study of 610 Chinese patients.

    Directory of Open Access Journals (Sweden)

    Xing-Yu Feng

    Full Text Available BACKGROUND: This study compared the performance of endoscopic ultrasonography (EUS and multislice spiral computed tomography (MSCT in the preoperative staging of gastric cancer. METHODOLOGY/PRINCIPAL FINDINGS: A total of 610 patients participated in this study, all of whom had undergone surgical resection, had confirmed gastric cancer and were evaluated with EUS and MSCT. Tumor staging was evaluated using the Tumor-Node-Metastasis (TNM staging and Japanese classification. The results from the imaging modalities were compared with the postoperative histopathological outcomes. The overall accuracies of EUS and MSCT for the T staging category were 76.7% and 78.2% (P=0.537, respectively. Stratified analysis revealed that the accuracy of EUS for T1 and T2 staging was significantly higher than that of MSCT (P<0.001 for both and that the accuracy of MSCT in T3 and T4 staging was significantly higher than that of EUS (P<0.001 and 0.037, respectively. The overall accuracy of MSCT was 67.2% when using the 13th edition Japanese classification, and this percentage was significantly higher than the accuracy of EUS (49.3% and MSCT (44.6% when using the 6th edition UICC classification (P<0.001 for both values. CONCLUSIONS/SIGNIFICANCE: Our results demonstrated that the overall accuracies of EUS and MSCT for preoperative staging were not significantly different. We suggest that a combination of EUS and MSCT is required for preoperative evaluation of TNM staging.

  11. Diagnosis of accessory conduction pathway using ECG-gated emission CT analysis

    International Nuclear Information System (INIS)

    Misaki, Takuro; Mukai, Keiichi; Tsubota, Makoto; Iwa, Takashi; Nakajima, Ken-ichi; Hisada, Kin-ichi

    1987-01-01

    Pinpointing the location of accessory conduction pathway (ACP) is of great importance in the surgical treatment for Wolff-Parkinson-White (WPW) syndrome. For this purpose, this study explored the usefulness of ECG-gated emission computed tomography (Gated-ECT) in 30 patients who preoperatively underwent Gated-ECT. The site of earliest contraction at level of atrioventicular valves, obtained on tomographic phase analysis, was compared with the site of earliest activation, obtained on epicardial mapping during surgery. The concordance rate of the two methods was 94 % (28/30). Among them, one patient was found to have the association of corrected transposition of great arteries on Gated-ECT. Gated-ECT was, however, of limited value in differentiating right posterior ACP from right postseptal ACP. The discordance between the sites of earliest contraction and activation, which was observed in the two others, was likely due to decreased wall motion resulting from myocardial disturbance. Gated-ECT may have a diagnostic potential for the location of ACP, especially in view of providing images that corresponded to the surgical anatomy. (Namekawa, K.)

  12. The usefulness of treatment evaluation of severe heart failure by ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Ohkoshi, Nobuyuki; Watanabe, Shingo; Matsumoto, Tooru

    2011-01-01

    Our purpose of study was to investigate the usefulness of treatment evaluation of severe heart failure by Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT). We evaluated the cardiac function in the case of severe heart failure by gated SPECT and compared it with the cardiac function obtained by left ventriculography (LVG), echocardiography, cardiac MRI, and B-type natriuretic peptide (BNP) values. We investigated the correlation of ejection fraction (EF), time lag of wall motion between the septal and lateral walls of the left ventricle for cardiac resynchronization therapy (CRT) and wall thickening (WT). We classified the left ventricular (LV) into basal, middle and apical areas for comparison of WT. We investigated the effect of a perfusion defect score in these comparisons. The gated SPECT results were correlated with comparative subjects in EF. The results were correlated with MRI on the middle area of the LV in the comparison of WT. We thought it was possible that there was an effect from a perfusion defect score in a time lag comparison of wall motion. Treatment evaluation of severe heart failure by gated SPECT is useful, because it is able to obtain three-dimensional cardiac function analysis, and it offers objectivity and reproducible quantitative evaluation. At the same time, perfusion SPECT is helpful for CRT and LV-plasty. (author)

  13. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  14. Ventricular short-axis measurements in patients with pulmonary embolism: Effect of ECG-gating on variability, accuracy, and risk prediction

    International Nuclear Information System (INIS)

    Scheffel, Hans; Stolzmann, Paul; Leschka, Sebastian; Desbiolles, Lotus; Seifert, Burkhardt; Marincek, Borut; Alkadhi, Hatem

    2012-01-01

    Objective: To assess prospectively the intra- and interobserver variability, accuracy, and prognostic value of right and left ventricular short-axis diameter (RVd and LVd) measurements for risk stratification in patients with pulmonary embolism (PE) using ECG-gated compared to non-gated CT. Materials and methods: Sixty consecutive patients (33 women; mean age 58.7 ± 10.3 years) with suspicion of PE underwent both non-gated and ECG-gated chest CT. RVd and LVd on four-chamber views and intra- and interobserver agreements were calculated for both protocols. RVd/LVd ratios were calculated and were related to 30-days adverse clinical events using receiver operating characteristics with area-under-the-curve (AUC) analyses. Results: Both inter- and intraobserver variability showed narrower limits of agreement for all measurements with ECG-gated as compared to non-gated CT. Diameter measurements were significantly lower using non-ECG-gated CT as compared to ECG-gated CT for RVd and LVd (both p < .05). The AUC for the RVd/LVd ratio from ECG-gated CT was significantly larger than that from non-gated CT (0.956, 95% CI: 0.768–0.999 versus 0.675, 95% CI: 0.439–0.860; p = .048). Conclusion: RVd and LVd measurements from ECG-gated chest CT show less intra- and interobserver variability and more accurately reflect ventricular function. In our patient cohort ECG-gated chest CT allows better prediction of short-term outcome of patients with acute PE that needs to be validated in a larger outcome study

  15. Low flip angle spin-echo MR imaging to obtain better Gd-DTPA enhanced imaging with ECG gating

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Kawamitsu, Hideaki; Yoshikawa, Kazuaki; Kasai, Toshifumi; Yuasa, Koji; Ishida, Tetsuya

    1992-01-01

    ECG-gated spin-echo imaging (ECG-SE) can reduce physiological motion artifact. However, ECG-SE does not provide strong T1-weighted images because repetition time (TR) depends on heart rate (HR). We investigated the usefulness of low flip angle spin-echo imaging (LFSE) in obtaining more T1-dependent contrast with ECG gating. In computer simulation, the predicted image contrast and single-to-noise ratio (SNR) obtained for each flip angle (0-180deg) and each TR (300 msec-1200 msec) were compared with those obtained by conventional T1-weighted spin-echo imaging (CSE: TR=500 msec, TE=20 msec). In clinical evaluation, tissue contrast [contrast index (CI): (SI of lesion-SI of muslce) 2* 100/SI of muscle] obtained by CSE and LFSE were compared in 17 patients. At a TR of 1,000 msec, T1-dependent contrast increased with decreasing flip angle and that at 38deg was identical to that with T1-weighted spin-echo. SNR increased with the flip angle until 100deg, and that at 53deg was identical to that with T1-weighted spin-echo. CI on LFSE (74.0±52.0) was significantly higher than CI on CSE (40.9±35.9). ECG-gated LFSE imaging provides better T1-dependent contrast than conventional ECG-SE. This method was especially useful for Gd-DTPA enhanced MR imaging. (author)

  16. Noninvasive detection of coronary abnormalities in pediatric patients with Kawassaki disease using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Hou Yang; Guo Wenli; Yue Yong; Chen Liying; Guo Qiyong; Yu Xianyi; Wang Hong

    2006-01-01

    Objective: To evaluate the feasibility and value of detecting coronary artery lesions in Kawasaki disease using multi-slice computed tomography (MSCT). Methods: Thirty-four pediatric patients underwent 16-slice or 64-slice CT coronary, angiography. 18 patients were also examined with 2 dimension echocardiography (2DE). In all cases, visibility of coronary artery segment was recorded. The diameter of the LCA, RCA were measured in MSCTA and compared with 2DE. Correlation coefficient of dimension and coincidence rate of two methods were calculated. Results: Coronary artery lesions were found in 14 patients (22 branches) of the 34 cases with KD on MSCT. Six cases were dialated, 3 cases were dialated with aneurysms, 2 cases had aneurysms without dialation. Coronary artery stenosis in 1 eases, calcification in 2 cases. Three cases had multiple aneurysms with the presence of alternate stenosis that made the artery a bead-like appearance. CC of LM and RCA were 0.85, 0.91, respectively (P>0.05). Three coronary artery aneurysm in the distal RCA was missed by 2DE. MSCT could not detect slight or moderate mitral regurgitation in 2 patients and artery wall thickening in 5 patients. Conclusion: MSCT would be an effective complementary or alternative method for CDEC to evaluate coronary artery lesions non-invasively in pediatric patients with Kawasaki disease. (authors)

  17. Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time

    International Nuclear Information System (INIS)

    Zhang, Shi-Zheng; Hu, Xiu-Hua; Zhang, Qiao-Wei; Huang, Wen-Xin

    2005-01-01

    The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups' t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm). (orig.)

  18. An integrated bioimpedance—ECG gating technique for respiratory and cardiac motion compensation in cardiac PET

    International Nuclear Information System (INIS)

    Koivumäki, Tuomas; Nekolla, Stephan G; Fürst, Sebastian; Loher, Simone; Schwaiger, Markus; Vauhkonen, Marko; Hakulinen, Mikko A

    2014-01-01

    Respiratory motion may degrade image quality in cardiac PET imaging. Since cardiac PET studies often involve cardiac gating by ECG, a separate respiratory monitoring system is required increasing the logistic complexity of the examination, in case respiratory gating is also needed. Thus, we investigated the simultaneous acquisition of both respiratory and cardiac gating signals using II limb lead mimicking electrode configuration during cardiac PET scans of 11 patients. In addition to conventional static and ECG-gated images, bioimpedance technique was utilized to generate respiratory- and dual-gated images. The ability of the bioimpedance technique to monitor intrathoracic respiratory motion was assessed estimating cardiac displacement between end-inspiration and -expiration. The relevance of dual gating was evaluated in left ventricular volume and myocardial wall thickness measurements. An average 7.6  ±  3.3 mm respiratory motion was observed in the study population. Dual gating showed a small but significant increase (4 ml, p = 0.042) in left ventricular myocardial volume compared to plain cardiac gating. In addition, a thinner myocardial wall was observed in dual-gated images (9.3  ±  1.3 mm) compared to cardiac-gated images (11.3  ±  1.3 mm, p = 0.003). This study shows the feasibility of bioimpedance measurements for dual gating in a clinical setting. The method enables simultaneous acquisition of respiratory and cardiac gating signals using a single device with standard ECG electrodes. (paper)

  19. The investigation of the lateral atlanto-dental interval of atlanto-axial joint by multi-slice spiral CT

    International Nuclear Information System (INIS)

    Cui Wei; Peng Lei; Wang Jincai; Liu Jihua; Feng Weihua

    2010-01-01

    Objective: To explore imaging features of the lateral atlanto-dental interval (LADI) of atlanto-axial joint and its value in the diagnosis of atlanto-axial joint dislocation/subluxation. Methods: Two hundred and forty healthy volunteers without atlanto-axial joint dysfunction and 32 patients with torticollis and/or functional impairment at atlanto-axial.joint were enrolled into this study. All subjects were examined with multi-slice CT in both neutral and max rotation positions to the left/right. Clinical endpoints including VBLADI, variance range of the VBLADI and asymmetric conditions were evaluate. χ 2 test is used to evaluate the variance of incidence of bilateral LADI asymmetry in different age groups, Pearson-test (2-tailed) is used to evaluate the correlation between VBLADI and rotary function of atlanto-axial joint, precise test of fourfold table is used to compare normal group with patient groups. Results: (1) In the normal control group: asymmetry of bilateral LADI were observed in 204 among 240 (85.00%) healthy volunteers including 60 youngsters ( 95% of ∣ VBLADI ∣ were 0.850 mm, 2.450 mm in the young ( 95% in the young and in the adult respectively. There was no correlation between VBLADI(-2.146 to 2.114 mm, Median 0.000 mm) and LA (22.949° to 44.649°, Median 34.500°), RA (25.284° to 45.334°, Median 35.300°), VLRA (-11.643° to 8.623°, median 0.000°) respectively in normal people (r=-0.030, -0.005, 0.026, P>0.05). (2) In the study with 32 patients including 25 youngsters ( 95% in group AALSD and group AACD than in abnormal group (P<0.01), but there is no difference between group AARD and normal group (P=0.738). Conclusion: The imaging finding of 'asymmetry of bilateral LADI' may be either a physiological variation or a pathological condition, clinical manifestations and other imaging findings should be evaluated to make a diagnosis. (authors)

  20. Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko; Kuwahara, Sadatoshi; Mehta, Dhruv

    2009-01-01

    We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution

  1. The evaluation of anti-angiogenic treatment effects for implanted rabbit VX2 breast tumors using functional multi-slice spiral computed tomography (f-MSCT)

    Energy Technology Data Exchange (ETDEWEB)

    Lei Zhen, E-mail: leizhen2004@163.com [Department of Anatomy, Chinese Medical University, No. 92, Beiermalu Road, Heping District, Shenyang, 110001 (China) and Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Ma Heji, E-mail: maheji9831@sina.com [Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Xu Na, E-mail: xuna821230@sohu.com [Department of Radiology, The First Hospital of Liaoning Medical College, No. 2, Wuduan, Renmin Street, Jinzhou, 121001 (China); Xi Huanjiu, E-mail: xihuanjiu2004@yahoo.cn [Anthropology Institute, Liaoning Medical College, No. 40, Sanduan, Songpo Rd, Jinzhou, 121001 (China)

    2011-05-15

    Objective: Investigate the benefit of functional multi-slice spiral computed tomography (f-MSCT) perfusion imaging in the non-invasive assessment of targeted anti-angiogenesis therapy on an implanted rabbit VX2 breast tumor model. Method: 69 female pure New Zealand white rabbits were randomly assigned to one of the 4 groups and received treatment accordingly: control (saline), Endostar, neoadjuvant chemotherapy (Cyclophosphamide, Epirubicin and 5-Fluorouracil, CEF), combination therapy (Endostar and CEF). After 2 weeks of treatment, f-MSCT perfusion scannings were performed for all rabbits and information about blood flow (BF), blood volume (BV), mean transit time (MTT) and surface permeability (SP) was collected. After perfusion imaging, tumor tissues were sampled for immunohistochemistry and the Western blot test of VEGF protein expression. Results: (1) The VEGF expression level, measured by immunohistochemistry and Western blot, decreased by treatment group (control > Endostar > CEF > combination therapy). The same was true for the mean BF, BV, MTT and PS, which decreased from the control group to the combination therapy group gradually. The mean MTT level increased in reverse order from the control to the combination therapy group. The difference between any 2 groups on these measures was statistically significant (P < 0.05). (2) There was moderate positive correlation between VEGF expression and BE, BV, or PS level (P < 0.05) and a negative correlation between VEGF expression and MTT level for all 4 groups (P < 0.05). Conclusion: Therefore, f-MSCT can be used as a non-invasive approach to evaluate the effect of anti-angiogenic therapy for implanted rabbit VX2 breast tumors.

  2. The evaluation of anti-angiogenic treatment effects for implanted rabbit VX2 breast tumors using functional multi-slice spiral computed tomography (f-MSCT)

    International Nuclear Information System (INIS)

    Lei Zhen; Ma Heji; Xu Na; Xi Huanjiu

    2011-01-01

    Objective: Investigate the benefit of functional multi-slice spiral computed tomography (f-MSCT) perfusion imaging in the non-invasive assessment of targeted anti-angiogenesis therapy on an implanted rabbit VX2 breast tumor model. Method: 69 female pure New Zealand white rabbits were randomly assigned to one of the 4 groups and received treatment accordingly: control (saline), Endostar, neoadjuvant chemotherapy (Cyclophosphamide, Epirubicin and 5-Fluorouracil, CEF), combination therapy (Endostar and CEF). After 2 weeks of treatment, f-MSCT perfusion scannings were performed for all rabbits and information about blood flow (BF), blood volume (BV), mean transit time (MTT) and surface permeability (SP) was collected. After perfusion imaging, tumor tissues were sampled for immunohistochemistry and the Western blot test of VEGF protein expression. Results: (1) The VEGF expression level, measured by immunohistochemistry and Western blot, decreased by treatment group (control > Endostar > CEF > combination therapy). The same was true for the mean BF, BV, MTT and PS, which decreased from the control group to the combination therapy group gradually. The mean MTT level increased in reverse order from the control to the combination therapy group. The difference between any 2 groups on these measures was statistically significant (P < 0.05). (2) There was moderate positive correlation between VEGF expression and BE, BV, or PS level (P < 0.05) and a negative correlation between VEGF expression and MTT level for all 4 groups (P < 0.05). Conclusion: Therefore, f-MSCT can be used as a non-invasive approach to evaluate the effect of anti-angiogenic therapy for implanted rabbit VX2 breast tumors.

  3. Value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression

    Directory of Open Access Journals (Sweden)

    Ai-Jun Wu

    2016-12-01

    Full Text Available Objective: To study the value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression. Methods: A total of 135 patients with gastric cancer who received surgical resection in our hospital between May 2012 and October 2015 were selected as the research subjects, preoperative enhanced multi-slice spiral CT scan was conducted to judge TNM staging, and serum was collected to determine the content of tumor markers; tumor tissue was collected after operation to determine the content of cytokines and pro-proliferation molecules. Results: CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM II, III and IV stage gastric cancer were significantly higher than those of patients with TNM I stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM III and IV stage gastric cancer were significantly higher than those of patients with TNM II stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM IV stage gastric cancer were significantly higher than those of patients with TNM III stage. Conclusions: TNM staging of gastric cancer decided by preoperative enhanced multi-slice spiral CT scan has good consistency with the content of tumor markers in serum and proliferation molecules in tumor lesion.

  4. Review: Pre- and postinterventional control of stent grafts by means of single and multislice spiral computerized tomography

    International Nuclear Information System (INIS)

    Gebauer, B.; Knollmann, F.; Steinkamp, H.; Felix, R.

    2003-01-01

    Purpose. Could contrast enhanced computed tomography replace conventional catheter angiography in the preoperative evaluation of aortic aneurysms before stentgraft implantation? Does multi slice computed tomography have advantages comparing to single slice computed tomography? Methods. We compared 15 single slice with 13 multi slice computed tomography studies and reconstructions according to their ability to replace conventional catheter angiography in the preoperative evaluation. In the postoperative follow-up 60 single slice computed tomography studies were compared to 60 multi slice studies. Results. By using appropriate reconstructions the spiral computed tomography studies could deliver all information necessary for implantation. In our study no advantage of multi slice computed tomography could be detected. In the postoperative evaluation of stengrafts our computed tomography scan protocol could detect all relevant complications in single and multi slice computed tomography. No significant advantage of multi slice computed tomography could be detected. Conclusion. Contrast enhanced computed tomography is equal to conventional catheter angiography in the pre- and postoperative evaluation of stentgrafts. No significant advantage of multi slice versus single slice could be detected. (orig.) [de

  5. Impact of ECG gating in contrast-enhanced MR angiography for the assessment of the pulmonary veins and the left atrium anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, M.; Buecker, A.; Muehlenbruch, G.; Guenther, R.W.; Spuentrup, E. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum RWTH Aachen (Germany); Schauerte, P. [Medizinische Klinik 1, Universitaetsklinikum RWTH Aachen (Germany)

    2006-02-15

    Purpose: Implementation of ECG gating in contrast-enhanced MR angiography (ceMRA) for improved visualization of the pulmonary veins, the left atrium, and the thoracic vessels. Materials and Methods: CeMRA was performed on twelve patients with a history of recurrent atrial fibrillation for the purpose of an intra-individual comparison with and without ECG gating on a 1.5 Tesla MR system (Gyroscan Intera, Philips Medical Systems, Best, NL). Objective image quality parameters such as the signal-to-noise ratio (SNR) of the blood and the contrast-to-noise ratio (CNR) between the blood and myocardium or lung parenchyma were analyzed. The contour sharpness of the pulmonary veins, left atrium, ascending aorta, and pulmonary trunk was also measured. In addition, the artifact level was subjectively assessed by two observers blinded with respect to the sequence parameters. Statistically significant differences (p<0.05) between the procedures were analyzed using the Wilcoxon test and Pearson Chi-square test. Results: The use of ECG gating in ceMRA significantly reduced artifacts caused by cardiac motion and vessel pulsation. This in turn lead to a significant increase in the contour sharpness of the left atrium and the thoracic vessels. In addition, higher SNR and CNR were found using ECG-gated ceMRA compared to standard ceMRA. Conclusion: The use of ECG gating in ceMRA results in artifact-free and sharper delineation of the structures of the heart and thoracic vessels. (orig.)

  6. Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm.

    Science.gov (United States)

    Lee, Ji Won; Kim, Chang Won; Lee, Geewon; Lee, Han Cheol; Kim, Sang-Pil; Choi, Bum Sung; Jeong, Yeon Joo

    2018-02-01

    Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

  7. Impact of ECG gating in contrast-enhanced MR angiography for the assessment of the pulmonary veins and the left atrium anatomy

    International Nuclear Information System (INIS)

    Katoh, M.; Buecker, A.; Muehlenbruch, G.; Guenther, R.W.; Spuentrup, E.; Schauerte, P.

    2006-01-01

    Purpose: Implementation of ECG gating in contrast-enhanced MR angiography (ceMRA) for improved visualization of the pulmonary veins, the left atrium, and the thoracic vessels. Materials and Methods: CeMRA was performed on twelve patients with a history of recurrent atrial fibrillation for the purpose of an intra-individual comparison with and without ECG gating on a 1.5 Tesla MR system (Gyroscan Intera, Philips Medical Systems, Best, NL). Objective image quality parameters such as the signal-to-noise ratio (SNR) of the blood and the contrast-to-noise ratio (CNR) between the blood and myocardium or lung parenchyma were analyzed. The contour sharpness of the pulmonary veins, left atrium, ascending aorta, and pulmonary trunk was also measured. In addition, the artifact level was subjectively assessed by two observers blinded with respect to the sequence parameters. Statistically significant differences (p<0.05) between the procedures were analyzed using the Wilcoxon test and Pearson Chi-square test. Results: The use of ECG gating in ceMRA significantly reduced artifacts caused by cardiac motion and vessel pulsation. This in turn lead to a significant increase in the contour sharpness of the left atrium and the thoracic vessels. In addition, higher SNR and CNR were found using ECG-gated ceMRA compared to standard ceMRA. Conclusion: The use of ECG gating in ceMRA results in artifact-free and sharper delineation of the structures of the heart and thoracic vessels. (orig.)

  8. Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

    International Nuclear Information System (INIS)

    Ketelsen, Dominik; Luetkhoff, Marie H.; Thomas, Christoph; Werner, Matthias; Tsiflikas, Ilias; Reimann, Anja; Kopp, Andreas F.; Claussen, Claus D.; Heuschmid, Martin; Buchgeister, Markus; Burgstahler, Christof

    2009-01-01

    The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol. (orig.)

  9. ECG-gated blood pool tomography in the determination of left ventricular volume, ejection fraction, and wall motion

    International Nuclear Information System (INIS)

    Underwood, S.R.; Ell, P.J.; Jarritt, P.H.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    ECG-gated blood pool tomography promises to provide a ''gold standard'' for noninvasive measurement of left ventricular volume, ejection fraction, and wall motion. This study compares these measurements with those from planar radionuclide imaging and contrast ventriculography. End diastolic and end systolic blood pool images were acquired tomographically using an IGE400A rotating gamma camera and Star computer, and slices were reconstructed orthogonal to the long axis of the heart. Left ventricular volume was determined by summing the areas of the slices, and wall motion was determined by comparison of end diastolic and end systolic contours. In phantom experiments this provided an accurate measurement of volume (r=0.98). In 32 subjects who were either normal or who had coronary artery disease left ventricular volume (r=0.83) and ejection fraction (r=0.89) correlated well with those using a counts based planar technique. In 16 of 18 subjects who underwent right anterior oblique X-ray contrast ventriculography, tomographic wall motion agreed for anterior, apical, and inferior walls, but abnormal septal motion which was not apparent by contrast ventriculography, was seen in 12 subjects tomographically. All 12 had disease of the left anterior descending coronary artery and might have been expected to have abnormal septal motion. ECG-gated blood pool tomography can thus determine left ventricular volume and ejection fraction accurately, and provides a global description of wall motion in a way that is not possible from any single planar image

  10. Design and development of a new pulsating cardiac coronary phantom for ECG-gated CT and its experimental characteristics

    International Nuclear Information System (INIS)

    Shen, Yun; Sato, Munekuni; Kimura, Fumiko; Jinzaki, Masahiro; Kuribayashi, Sachio; Horiguchi, Jun; Ito, Katsuhide

    2005-01-01

    The optimal pulsating cardiac phantom is an important tool for the evaluation of cardiac images and cardiac applications on electrocardiogram (ECG)-gated multidetector-row CT (MDCT). The purpose of this study was to demonstrate the design and fabrication of the pulsating cardiac coronary phantom. The newly developed pulsating cardiac coronary phantom has the following five key advantages: a driver component that uses only one servomotor to move the phantom in three dimensions (X, Y, and Z directions) with 16 presets of different heart types (heartbeat: 0-120 bpm; ejection fraction: 0-90%); versatile pumping and filling phases to simulate a real heart in a cardiac cycle can be incorporated into the driver sequence including shift of patient heartbeat or irregular pulse (maximum: 200 different heart waves in one scan); a cardiac coronary component constituted of an acrylic/silicon/rubber tube (2-6 mm inner diameter) with stent/in-stent restenosis/stenosis/soft plaque/calcification parts and maximum 16 coronary arteries that can be attached to the phantom in the same scan; the complete phantom can be submerged in a tank to simulate the heart and its surrounding tissues; ECG gating can be from interior trigger and exterior trigger. It has been confirmed that the developed pulsating cardiac phantom is very useful to quantitatively assess imaging of the heart and coronary arteries during phantom experiments. (author)

  11. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  12. MR flow measurements for assessment of the pulmonary, systemic and bronchosystemic circulation: Impact of different ECG gating methods and breathing schema

    International Nuclear Information System (INIS)

    Ley, Sebastian; Ley-Zaporozhan, Julia; Kreitner, Karl-Friedrich; Iliyushenko, Svitlana; Puderbach, Michael; Hosch, Waldemar; Wenz, Heiner; Schenk, Jens-Peter; Kauczor, Hans-Ulrich

    2007-01-01

    Purpose: Different ECG gating techniques are available for MR phase-contrast (PC) flow measurements. Until now no study has reported the impact of different ECG gating techniques on quantitative flow parameters. The goal was to evaluate the impact of the gating method and the breathing schema on the pulmonary, systemic and bronchosystemic circulation. Material and methods: Twenty volunteers were examined (1.5 T) with free breathing phase-contrast flow (PC-flow) measurements with prospective (free-prospective) and retrospective (free-retrospective) ECG gating. Additionally, expiratory breath-hold retrospective ECG gated measurements (bh-retrospective) were performed. Blood flow per minute; peak velocity and time to peak velocity were compared. The clinically important difference between the systemic and pulmonary circulation (bronchosystemic shunt) was calculated. Results: Blood flow per minute was lowest for free-prospective (6 l/min, pulmonary trunc) and highest for bh-retrospective measurements (6.9 l/min, pulmonary trunc). No clinically significant difference in peak velocity was assessed (82-83 cm/s pulmonary trunc, 109-113 cm/s aorta). Time to peak velocity was shorter for retro-gated free-retrospective and bh-retrospective than for pro-gated free-prospective. The difference between systemic and pulmonary measurements was least for the free-retrospective technique. Conclusion: The type of gating has a significant impact on flow measurements. Therefore, it is important to use the same ECG gating method, especially for follow-up examinations. Retrospective ECG gated free breathing measurements allow for the most precise assessment of the bronchosystemic blood flow and should be used in clinical routine

  13. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction; Mehrschicht-Spiral-CT (MSCT) beim Mittelgesichtstrauma: Optimierung der Aufnahme- und Rekonstruktionsparameter

    Energy Technology Data Exchange (ETDEWEB)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E. [Abt. Roentgendiagnostik I, Georg-August-Univ. Goettingen (Germany); Merten, H.A. [Abt. fuer Mund-, Kiefer- und Gesichtschirurgie, Georg-August-Univ. Goettingen (Germany)

    2002-07-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [German] Zielsetzung: Verbesserung der Aufnahme- und Rekonstruktionsparameter in der Mehrschicht Spiral-CT (MSCT) zur Untersuchung des knoechernen Mittelgesichtes in verschiedenen Ebenen. Material und Methode: Ein anthropomorphes Schaedel-Phantom wurde in axialer Schichtfuehrung mit einem MSCT untersucht, wobei die Kollimation (1,25 - 2,5 mm), der Tischvorschubfaktor (Pitch 3 - 6) und der Roehrenstrom (20 - 200 mA) systematisch variiert wurden. Aus den Volumendatensaetzen wurden jeweils koronare und parasagittale Sekundaerreformationen mit unterschiedlichen

  14. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  15. Assessment of the effect of revascularization early after CABG using ECG-gated perfusion single-photon emission tomography

    International Nuclear Information System (INIS)

    Kubo, Shigeto; Tadamura, Eiji; Kudoh, Takashi; Inubushi, Masayuki; Konishi, Junji; Ikeda, Tadashi; Koshiji, Takaaki; Nishimura, Kazunobu; Komeda, Masashi; Tamaki, Nagara

    2001-01-01

    When an arterial graft is used, reversible perfusion defects on single-photon emission tomography (SPET) perfusion images are occasionally observed early after coronary artery bypass graft surgery (CABG), owing to the restricted flow capacity. The purpose of this study was to determine whether the functional information obtained with electrocardiography (ECG)-gated perfusion SPET could be helpful in evaluating the effect of revascularization early after CABG. Twenty-three patients (18 men and 5 women, mean age 65±9 years) underwent stress/re-injection thallium-201 ECG-gated SPET before and 4 weeks after CABG (13 with exercise and 10 with dipyridamole). Patency of all grafts was confirmed by coronary angiography 1 month after CABG. Cardiac functional data including the left ventricular ejection fraction (LVEF) and the transient ischaemic dilatation (TID) ratio were analysed using a commercially available automated program. The conventional stress and re-injection tomograms were interpreted by means of a five-point scoring system in a nine-segment model. Stress-induced reversible 201 Tl perfusion defects were present in 64% of the myocardial segments bypassed by patent arterial grafts, in contrast to 42% of the myocardial segments bypassed by patent venous grafts (χ 2 =7.8, P=0.005). Of the 23 patients, 12 showed improvement in summed ischaemic scores (group 1), while 11 had no change or deterioration (group 2), although all grafts were patent on postoperative catheterization. The TID ratio improved in both group 1 and group 2 before and after CABG (1.14±0.13 vs 0.99±0.07, P=0.001 and 1.09±0.07 vs 0.94±0.05, P=0.002, respectively). However, LVEF did not significantly improve in group 1 or group 2 after CABG (42.5%±9.9% vs 47.5%±11.8%, and 52.1%±7.5% vs 53.1%±5.9%, respectively). Perfusion imaging or LVEF assessment is of limited value early after CABG. The TID ratio obtained with ECG-gated perfusion SPET may be a useful marker to evaluate the effect of

  16. Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients

    International Nuclear Information System (INIS)

    Salem, Randa; Remy-Jardin, Martine; Delhaye, Damien; Khalil, Chadi; Teisseire, Antoine; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2006-01-01

    The purpose of this study was to investigate the possibility of assessing the underlying respiratory disease as well as cardiac function during ECG-gated CT angiography of the chest with 64-slice multidetector-row CT (MDCT). One hundred thirty-three consecutive patients in sinus rhythm with known or suspected ventricular dysfunction underwent an ECG-gated CT angiographic examination of the chest without β-blockers using the following parameters: (1) collimation: 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices (Sensation 64; Siemens); rotation time: 0.33 s; pitch: 0.3; 120 kV; 200 mAs; ECG-controlled dose modulation (ECG-pulsing) and (2) 120 ml of a 35% contrast agent. Data were reconstructed: (1) to evaluate the underlying respiratory disease (1-mm thick lung and mediastinal scans reconstructed at 55% of the R-R interval; i.e., ''morphologic scans'') and (2) to determine right (RVEF) and left (LVEF) ventricular ejection fractions (short-axis systolic and diastolic images; Argus software; i.e., ''functional scans''). The mean heart rate was 73 bpm (range: 42-120) and the mean scan time was 18.11±2.67 s (range: 10-27). A total of 123 examinations (92%) had both lung and mediastinal images rated as diagnostic scans, whereas 10 examinations (8%) had non-diagnostic images altered by the presence of respiratory-motion artifacts (n=4) or cyclic artifacts related to the use of a pitch value of 0.3 in patients with a very low heart rate during data acquisition (n=6). Assessment of right and left ventricular function was achievable in 124 patients (93%, 95% CI: 88-97%). For these 124 examinations, the mean RVEF was 46.10% (±9.5; range: 20-72) and the mean LVEF was 58.23% (±10.88; range: 20-83). In the remaining nine patients, an imprecise segmentation of the right and left ventricular cavities was considered as a limiting factor for precise calculation of end-systolic and end-diastolic ventricular volumes. The mean (±SD) DLP

  17. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    International Nuclear Information System (INIS)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa

    1997-01-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF's derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  18. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa [Osaka Univ. (Japan). Faculty of Medicine] [and others

    1997-08-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF`s derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  19. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio [University Hospital ' ' S.Orsola' ' , Cardio-Thoracic-Vascular Department, Cardio-Thoracic Radiology Unit, Bologna (Italy)

    2016-02-15

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  20. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio

    2016-01-01

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  1. The application and value of 64 multislice spiral CT of left atrium and pulmonary vein in radio-frequency ablation of atrial fibrillation

    International Nuclear Information System (INIS)

    Guo Xi; Lv Biao; Zhang Zhaoqi; Zhao Yike; Jiang Hong; Ma Changsheng; Yu Ronghui; Wang Xue; Cao Hainian

    2008-01-01

    Objective: Analyzing the left atrium and pulmonary vein morphologically by 64 multislice spiral CT (MSCT) scan to guide the catheter ablation of Atrial fibrillation. Methods: Two hundred and thirty-two patients (146 cases in atrial fibrillation group and 86 cases in control group) received 64 MSCT examination of the left atrium and pulmonary vein. The incidence of anatomical variation of pulmonary vein was compared between atrial fibrillation group and control group. For each group, the anatomical morphology of every pulmonary vein and the auricle of left atrium was analyzed, the diameter of the orifice of each pulmonary vein and the size of left atrium were measured. Results: Sixty-four MSCT of left atrium and pulmonary vein could demonstrate detailed connecting type between left atrium and pulmonary veins and the possible anatomical variation. Anatomical variation of pulmonary vein in this study accounted for 16.8% (39/232) of total sample. For both groups, orifices of pulmonary veins appeared oval and their superoinferior diameters were larger than their anteroposterior diameters. There was significant difference in the inner diameter of left atrium between atrial fibrillation group and control group [atrial fibrillation group: (39.47 ± 8.98) mm, control group: (36.94±5.49) mm, P=0.02], while there was no difference in the diameters of orifices of pulmonary veins between two groups [superoinferior diameters of pulmonary veins in atrial fibrillation group: left-up (18.15±1.35) mm, left-down (16.96±1.18) mm, right-up (17.50±1.12) mm, fight-down (17.65±0.94) mm, superoinferior diameters of pulmonary veins in control group: left-up (18.07±0.94) mm, left-down (17.50±0.57) mm, right-up (18.03±1.02) mm, fight-down (17.94±0.76) mm, the corresponding P>0.05, respectively, anteroposterior diameters of pulmonary veins in atrial fibrillation group: left-up (12.26±1.89) mm, left-down (11.96±0.61) mm, right-up (12.32± 1.08) mm, fight-down (12.39±0.95) mm

  2. Pulmonary artery and right ventricle assessment in pulmonary hypertension. Correlation between functional parameters of ECG-gated CT and right-side heart catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Abel, Elodie; Jankowski, Adrien [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Pison, Christophe [Clinique univ. de pneumologie, CHU Grenoble (France); Bosson, Jean Luc [Dept. of Statistics, CIC, CHU Grenoble (France); Bouvaist, Helene [Clinique univ. de cardiologie, CHU Grenoble (France); Ferretti, Gilbert R. [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Univ. J. Fourier, Grenoble (France); INSERM U 823, Inst. A. Bonniot, la Tronche (France)], e-mail: gferretti@chu-grenoble.fr

    2012-09-15

    Background: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. Purpose: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. Material and Methods: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. Results: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P 0.005) correlated equally with RHC-CO. Conclusion: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for

  3. Pulmonary artery and right ventricle assessment in pulmonary hypertension. Correlation between functional parameters of ECG-gated CT and right-side heart catheterization

    International Nuclear Information System (INIS)

    Abel, Elodie; Jankowski, Adrien; Pison, Christophe; Bosson, Jean Luc; Bouvaist, Helene; Ferretti, Gilbert R.

    2012-01-01

    Background: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. Purpose: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. Material and Methods: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. Results: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P 0.005) correlated equally with RHC-CO. Conclusion: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for evaluating

  4. Calculation of left ventricular volume and ejection fraction from ECG-gated myocardial SPECT. Automatic detection of endocardial borders by threshold method

    International Nuclear Information System (INIS)

    Fukushi, Shoji; Teraoka, Satomi.

    1997-01-01

    A new method which calculate end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) of the left ventricle from myocardial short axis images of ECG-gated SPECT using 99m Tc myocardial perfusion tracer has been designed. Eight frames per cardiac cycle ECG-gated 180 degrees SPECT was performed. Threshold method was used to detect myocardial borders automatically. The optimal threshold was 45% by myocardial SPECT phantom. To determine if EDV, ESV and LVEF can also be calculated by this method, 12 patients were correlated ventriculography (LVG) for 10 days each. The correlation coefficient with LVG was 0.918 (EDV), 0.935 (ESV) and 0.900 (LVEF). This method is excellent at objectivity and reproductivity because of the automatic detection of myocardial borders. It also provides useful information on heart function in addition to myocardial perfusion. (author)

  5. Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Ke Shi

    Full Text Available To evaluate the feasibility and diagnostic accuracy of retrospective electrocardiographically (ECG-gated dual-source computed tomography (DSCT for the assessment of double outlet right ventricle (DORV and associated multiple malformations in pediatric patients.Forty-seven patients <10 years of age with DORV underwent retrospective ECG-gated DSCT. The location of the ventricular septal defect (VSD, alignment of the two great arteries, and associated malformations were assessed. The feasibility of retrospective ECG-gated DSCT in pediatric patients was assessed, the image quality of DSCT and the agreement of the diagnosis of associated malformations between DSCT and transthoracic echocardiography (TTE were evaluated, the diagnostic accuracies of DSCT and TTE were referred to surgical results, and the effective doses were calculated.Apart from DORV, 109 associated malformations were confirmed postoperatively. There was excellent agreement (κ = 0.90 for the diagnosis of associated malformations between DSCT and TTE. However, DSCT was superior to TTE in demonstrating paracardiac anomalies (sensitivity, coronary artery anomalies: 100% vs. 80.00%, anomalies of great vessels: 100% vs. 88.57%, separate thoracic and abdominal anomalies: 100% vs. 76.92%, respectively. Combined with TTE, DSCT can achieve excellent diagnostic performance in intracardiac anomalies (sensitivity, 91.30% vs. 100%. The mean image quality score was 3.70 ± 0.46 (κ = 0.76. The estimated mean effective dose was < 1 mSv (0.88 ± 0.34 mSv.Retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus expose the patients to a much lower radiation dose.

  6. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Wang Rui; Zhang Zhaoqi; Xu Lei; Ma Qin; He Yi; Lu Dongxu; Yu Wei; Fan Zhanming

    2011-01-01

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 ± 9.57 HU vs. 72.63 ± 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 ± 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  7. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J.; Xu, J.

    2010-01-01

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 ± 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  8. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Rui, E-mail: rui_wang1979@yahoo.cn [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Qin, E-mail: tel1367@gmail.com [Department of Emergency, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); He Yi, E-mail: heyi139@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lu Dongxu, E-mail: larry.hi@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2011-11-15

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 {+-} 9.57 HU vs. 72.63 {+-} 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 {+-} 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  9. Detection of Airway Anomalies in?Pediatric?Patients with Cardiovascular Anomalies with Low Dose Prospective ECG-Gated Dual-Source CT

    OpenAIRE

    Jiao, Hui; Xu, Zhuodong; Wu, Lebin; Cheng, Zhaoping; Ji, Xiaopeng; Zhong, Hai; Meng, Chen

    2013-01-01

    OBJECTIVES: To assess the feasibility of low-dose prospective ECG-gated dual-source CT (DSCT) in detecting airway anomalies in pediatric patients with cardiovascular anomalies compared with flexible tracheobronchoscopy (FTB). METHODS: 33 pediatrics with respiratory symptoms who had been revealed cardiovascular anomalies by transthoracic echocardiography underwent FTB and contrast material-enhanced prospective ECG-triggering CT were enrolled. The study was approved by our institution review bo...

  10. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J. [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Xu, J., E-mail: xujianr@hotmail.co [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China)

    2010-10-15

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 {+-} 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  11. Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain

    International Nuclear Information System (INIS)

    Runza, G.; La Grutta, L.; Alaimo, V.; Evola, S.; Lo Re, F.; Bartolotta, T.V.; Cademartiri, F.; Midiri, M.

    2007-01-01

    Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to scan the entire thorax visualizing the thoracic aorta, the pulmonary arteries, and the coronary arteries could provide a new approach to the triage of acute chest pain. The inherent advantage of MDCT with cardiac state-of-the-art capabilities is the rapid investigation of the main sources of acute chest pain with a high negative predictive value. Recent studies also reports an advantage in terms of costs. With current evidence, the selection of patients with acute chest pain candidates to MDCT should remain restricted to avoid unjustified risk of ionizing radiation

  12. Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Runza, G. [Department of Radiology, University of Palermo (Italy)], E-mail: grunza@sirm.org; La Grutta, L.; Alaimo, V. [Department of Radiology, University of Palermo (Italy); Evola, S. [Department of Cardiology, University of Palermo (Italy); Lo Re, F.; Bartolotta, T.V. [Department of Radiology, University of Palermo (Italy); Cademartiri, F. [Department of Radiology and Cardiology, Erasmus Medical Center, Rotterdam (Netherlands); Department of Radiology and Cardiology, Cardiovascular CT Unit, University Hospital, Parma (Italy); Midiri, M. [Department of Radiology, University of Palermo (Italy)

    2007-10-15

    Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to scan the entire thorax visualizing the thoracic aorta, the pulmonary arteries, and the coronary arteries could provide a new approach to the triage of acute chest pain. The inherent advantage of MDCT with cardiac state-of-the-art capabilities is the rapid investigation of the main sources of acute chest pain with a high negative predictive value. Recent studies also reports an advantage in terms of costs. With current evidence, the selection of patients with acute chest pain candidates to MDCT should remain restricted to avoid unjustified risk of ionizing radiation.

  13. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. New approach for simplified and automated measurement of left ventricular ejection fraction by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu; Adachi, Haruhiko; Sugihara, Hiroki; Katsume, Hiroshi; Ijichi, Hamao; Okamoto, Kunio; Hosoba, Minoru

    1984-12-01

    Background (BKG) correction is important but debatable in the measurement of Left ventricular ejection fraction (LVEF) with ECG gated blood pool scintigraphy. We devised a new simplified BKG processing (fixed BKG method) without BKG region-of-interest (ROI) assignment, and the accuracy and reproducibility were assessed in 25 patients with various heart diseases and 5 normal subjects by comparison with LVEF obtained by contrast levolgraphy (LVG-EF). Four additional protocols for LVEF measurement with BKG-ROI assignment were also assessed for reference. LVEF calculated using the fixed BKG ratio of 0.64 (BKG count rates were 64%) of end-diastolic count rates of LV) with ''Fixed'' LV-ROI was best correlated with LVG-EF (r = 0.936, p < 0.001) and most approximated (Fixed BKG ratio method EF: 61.1 +- 20.1, LVG-EF: 61.2 +- 20.4% (mean +- SD)) among other protocols. The wide availability of the fixed value of 0.64 was tested in various diseases, body size and end-diastolic volume by LVG, and the results were to be little influenced by them. Furthermore, fixed BKG method produced lower inter-and intra- observer variability than other protocols requiring BKG-ROI assignment, probably due to its simplified processing. In conclusion, fixed BKG ratio method simplifies the measurement of LVEF, and is feasible for automated processing and single probe system.

  15. Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients

    International Nuclear Information System (INIS)

    Delhaye, Damien; Remy-Jardin, Martine; Salem, Randa; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2007-01-01

    To evaluate image quality in the assessment of the coronary arteries during routine ECG-gated multidetector CT (MDCT) of the chest. One hundred and thirty three patients in sinus rhythm underwent an ECG-gated CT angiographic examination of the entire chest without β-blockers with a 64-slice CT system. In 127 patients (95%), it was possible to assess the coronary arteries partially or totally; coronary artery imaging failed in six patients (5%), leading to a detailed description of the coronary arteries in 127 patients. Considering ten coronary artery segments per patient, 75% of coronary segments were assessable (948/1270 segments). When the distal segments were excluded from the analysis (i.e., seven coronary segments evaluated per patient), the percentage of assessable segments was 86% (768/889 proximal and mid coronary segments) and reached 93% (474/508) when assessing proximal segments exclusively. The mean number of assessable segments was significantly higher in patients with a heart rate ≤80 bpm (n=95) than in patients with a heart rate >80 bpm (n=38) (p<0.002). Proximal and mid-coronary segments can be adequately assessed during a whole-chest ECG-gated CT angiographic examination without administration of β-blockers in patients with a heart rate below 80 bpm. (orig.)

  16. The value of low-dose prospective ECG-gated dual-source CT angiography in the diagnosis of coarctation of the aorta in infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Nie, P. [Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong (China); Wang, X., E-mail: wxming369@yahoo.com.cn [Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong (China); Cheng, Z.; Duan, Y.; Ji, X. [Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong (China); Chen, J. [CT Research Collaboration, Siemens, Beijing (China); Zhang, H. [Department of Cardiovascular Surgery, Shandong Provincial Hospital, Jinan, Shandong (China)

    2012-08-15

    Aim: To investigate the value of prospective electrocardiogram (ECG)-gated dual-source computed tomography (DSCT) in the diagnosis of coarctation of the aorta (CoA). Materials and methods: Seventeen patients clinically suspected of having CoA underwent prospective ECG-gated DSCT angiography and transthoracic echocardiography (TTE). Surgery was performed in all patients. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. Image quality was evaluated using a five-point scale. Effective radiation dose was calculated from the dose-length product (DLP). Results: CoA was diagnosed in 17 patients by DSCT angiography and in 16 patients by TTE. A total of 46 separate cardiovascular abnormalities were confirmed by surgical findings. The diagnostic accuracy of DSCT angiography and TTE was 96.32% and 97.06%, respectively. There was no significant difference in the diagnostic accuracy between DSCT angiography and TTE ({chi}{sup 2} = 0, p > 0.05). The mean score of image quality was 4.2 {+-} 0.8. The mean effective dose was 0.69 {+-} 0.09 mSv. Conclusion: Prospective ECG-gated DSCT with a low radiation dose is a valuable technique in the diagnosis of CoA in infants and children.

  17. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  18. PET/CT和MSCT联合应用在孤立性肺结节诊断中的价值%PET-CT with multi-slice spiral CT in the diagnosis of SPN

    Institute of Scientific and Technical Information of China (English)

    汪世存; 方雷; 潘博; 展凤麟; 谢强; 谢吉奎

    2009-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射显像/电子计算机断层扫描成像(18F-deoxyglucose positron emission tomography /computer tomography 18F-FDG PET/CT)和多排CT( multi-slice spiral CT,MSCT)联合应用在孤立性肺结节(SPN)诊断中的价值.方法 87例SPN患者均行PET/CT及肺部病灶MSCT检查,影像诊断结果 与病理对照,进行统计分析.结果 87例SPN中,MSCT诊断正确64例,误诊23例,误诊率26.4%.PET/CT诊断正确70例,误诊17例,误诊率19.5%.MSCT和PET/CT联合诊断,80例诊断正确,7例误诊,误诊率8.0%.MSCT、PET/CT及两者联合诊断的敏感性、特异性和准确性分别为87.2%、68.1%、79.8%;89.5%、61.3%、81.4%和97.7%、74.2%、91.5%.MSCT和PET/CT单独诊断SPN的准确性无统计学意义(χ2=0.625,P=0.239),MSCT、PET/CT与两者联合应用诊断SPN的准确性均有统计学意义(χ2=7.762和5.318,P=0.005和0.021).结论 SPN的MSCT和PET/CT影像特征均有一定的重叠.单独采用MSCT或PET/CT诊断肺结节无明显统计学差异,MSCT和PET-CT协同诊断的准确性高于MSCT或PET/CT单独诊断.%Aim To evaluate the value of a combination of 18F-FDG PET-CT with multi-slice spiral CT in the diagnosis of SPN.Methods 18F-FDG PET-CT and multi-slice spiral CT were performed in 87 patients with SPN.The pathologically-proved findings were compared with findings diagnosed by MSCT and retrospectively analyzed.Results In 87 cases,the numbers of correct diagnosis and misdiagnosis with MSCT were 64 and 23 respectively,the misdiagnosis rate 26.4%,while the numbers of correct diagnosis and misdiagnosis with PET/CT were 70 and 17,the misdiagnosis rate 19.5%,but 50 cases were correctly diagnosed and 7 cases were misdiagnosed by combining 18F-FDG PET-CT with MSCT,the misdiagnosis rate 8.0%.The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of MSCT,PET/CT,and MSCT combined with PET /CT were 87.2%,68.1%,79.8%;89.5%,61.3%,81.4% and 97

  19. Quantification of left ventricular regional functions using ECG-gated myocardial perfusion SPECT. Validation of left ventricular systolic functions

    International Nuclear Information System (INIS)

    Yamamoto, Akira; Takahashi, Naoto; Iwahara, Shin-ichiro; Munakata, Kazuo; Hosoya, Tetsuo

    2006-01-01

    We have developed a program to quantify regional left ventricular (LV) function and wall motion synchrony using electrocardiogram (ECG)-gated myocardial perfusion SPECT (MPS). This preliminary study was undertaken to validate the use of this program for estimating regional LV systolic function. Patients were subjected to MPS by 99m Tc-sestamibi at rest. The study included 20 patients who were confirmed to have a low probability of coronary artery disease (LPG; low probability group), 19 heart disease patients who were examined by MPS and equilibrium radionuclide angiography (ERNA) (ERG; ERNA group), and 24 patients who were examined by MPS and 2-dimensional echocardiography (2DE) (2DEG; 2DE group). The values of the ejection fraction (EF) and peak ejection rate (PER) were estimated. The global functions evaluated by this program were compared with those obtained by ERNA in the ERG. For regional assessment, the reference values of the functional indices were obtained for 17 LV segments in LPG. The Z score, (reference average value of the segment-patient's value of the segment)/reference standard deviation of the segment, was used for the evaluation of regional functions; a score equal to or greater than 2 was defined as abnormal. Semiquantitative visual interpretation of 2DE was used as the standard to assess wall motion. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of these criteria and the relationship between 2DE grading and Z scoring were validated in 2DEG. The values of the global EF and PER evaluated by this program correlated with those determined by ERNA (r=0.76 and 0.58, respectively; p -10 ). The potential of this program to quantify the regional systolic function was validated. (author)

  20. Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers

    Science.gov (United States)

    Proença, Martin; Adler, Andy; Riedel, Thomas; Thiran, Jean-Philippe; Solà, Josep

    2018-01-01

    Cardiac output (CO) and stroke volume (SV) are parameters of key clinical interest. Many techniques exist to measure CO and SV, but are either invasive or insufficiently accurate in clinical settings. Electrical impedance tomography (EIT) has been suggested as a noninvasive measure of SV, but inconsistent results have been reported. Our goal is to determine the accuracy and reliability of EIT-based SV measurements, and whether advanced image reconstruction approaches can help to improve the estimates. Data were collected on ten healthy volunteers undergoing postural changes and exercise. To overcome the sensitivity to heart displacement and thorax morphology reported in previous work, we used a 3D EIT configuration with 2 planes of 16 electrodes and subject-specific reconstruction models. Various EIT-derived SV estimates were compared to reference measurements derived from the oxygen uptake. Results revealed a dramatic impact of posture on the EIT images. Therefore, the analysis was restricted to measurements in supine position under controlled conditions (low noise and stable heart and lung regions). In these measurements, amplitudes of impedance changes in the heart and lung regions could successfully be derived from EIT using ECG gating. However, despite a subject-specific calibration the heart-related estimates showed an error of 0.0 ± 15.2 mL for absolute SV estimation. For trending of relative SV changes, a concordance rate of 80.9% and an angular error of −1.0 ± 23.0° were obtained. These performances are insufficient for most clinical uses. Similar conclusions were derived from lung-related estimates. Our findings indicate that the key difficulty in EIT-based SV monitoring is that purely amplitude-based features are strongly influenced by other factors (such as posture, electrode contact impedance and lung or heart conductivity). All the data of the present study are made publicly available for further investigations. PMID:29373611

  1. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  2. Use of ECG-gated computed tomography, echocardiography and selective angiography in five dogs with pulmonic stenosis and one dog with pulmonic stenosis and aberrant coronary arteries.

    Science.gov (United States)

    Laborda-Vidal, P; Pedro, B; Baker, M; Gelzer, A R; Dukes-McEwan, J; Maddox, T W

    2016-12-01

    Pulmonic stenosis (PS) is the most common congenital cardiac disease in dogs. Boxers and English bulldogs are among the most commonly affected breeds and also commonly associated with an aberrant coronary artery (CA). If an aberrant CA is suspected and balloon valvuloplasty indicated, an intra-operative angiography is recommended prior to the procedure. ECG-gated computed tomography (CT) can be used to screen for CA anomalies in a quick and minimally-invasive way (preventing side effects associated with selective catheter angiography) and allowing early planning of the procedure. The aim of this case series was to report CT findings associated with PS diagnosed by echocardiography. Our database was retrospectively searched for cases of dogs with PS diagnosed by echocardiography, where an ECG-gated CT was performed. A total of six cases were retrieved: all were diagnosed with severe PS. Four dogs had concurrent congenital defects: two dogs had a patent ductus arteriosus, one dog had a ventricular septal defect and an overriding aorta, one dog had an aberrant CA. Detailed CT findings of all cases were reported, including one case of a patent ductus arteriosus and an overriding aorta not identified by transthoracic echocardiography. In addition, an abnormal single left coronary ostium, with a pre-pulmonic right CA was described. In conclusion, despite echocardiography remaining the gold standard for diagnosis and assessment of PS, ECG-gated-CT angiography is a complementary diagnostic method that may provide additional relevant information, shorten surgery/anaesthesia time and reduce the amount of radiation to which the clinician is subjected. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  4. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  5. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  6. Measurement of modulation transfer function in z-axis for multi-slice spiral CT using the micro-disk method. Comparison with the bead method and examination of geometric influence

    International Nuclear Information System (INIS)

    Hara, Takanori

    2003-01-01

    Many methods of measuring the section-sensitive profile (SSP) of computed tomography (CT) by the input of a delta function have been reported. In Japan, the bead method is used as a common measurement because of the high flexibility of the multi-purpose method. However, the intensity of the response of the bead method tends to decline, creating a relatively large error in the base of SSPs. A problem is considered to be the accuracy of measurement in evaluating spatial resolution along the z-axis in multi-slice spiral/helical CT (MSCT). We therefore evaluated the modulation transfer function (MTF) by conducting research with the micro-disk method (100 μm thickness and 1.0 mmφ diameter) and the bead method (1.0 mmφ diameter) for the same input width. Moreover, in the micro-disk method, we also examined alignment, circular region of interest (ROI), and the energy characteristic. Our comparison of MTFs obtained by the micro-disk method and the bead method showed that the former resulted in a higher value and lower standard deviation. The difference was significant at p<0.01. Measurement using the micro-disk method did not show significant differences in terms of alignment and ROIs. Moreover, the energy characteristic was not indicated. This research demonstrated that the accuracy of MTF measurement with the micro-disk method was greater than that with the bead method, and it was found that there was no influence on the actual measurement level of the geometric structure with the micro-disk method. (author)

  7. MSCT在主动脉壁内血肿诊断和转归中的应用%Application of multi-slice spiral CT in diagnosis and prognosis of aortic artery intramural hematoma

    Institute of Scientific and Technical Information of China (English)

    黄源义; 谢欢; 邬正宏; 刘四斌

    2011-01-01

    Objective To investigate the applied value of multi-slice spiral CT in diagnosis and prognoses of aortic artery intramural hematoma(IMH). Methods 11 patients with IMH underwent plain CT scan and CT angiography with 16-slice spiral CT of GE. Endovascular stent for the treatment in 3 cases and conservative treatment in 8 cases was performed. All patients were followed-up twice or 4 times for 15 - 210 days(mean 112. 5 days). Results 3 cases with Stanford A and 8 cases with Stanford B IMH were diagnosed. The main CT findings were as follows: Crescent or circular thickening(>5 mm)of aortic wall with higher density or isodensi-ty without intimal flap as well as true and false lumen in 11 cases;atherosclerosis in 7 cases;intimal calcification ingression in 4 cases; intimal leakages in 3 cases;penetrating ulcer in 3 cases. The hematomas in 7 cases were completely absorbed,incomplete absorbed in 2 cases,while 2 cases were transformed to dissecting aneurysm. Conclusion MSCT is a significant method in diagnosis and follow-ing-up of IMH, and can provide important informations for clinical treatment.%目的 探讨MSCT在主动脉壁内血肿(IMH)诊断和转归中的应用价值.方法 采用GE 16排螺旋CT对11例IMH行平扫和CTA扫描.3例行腔内支架隔绝术,8例保守治疗.所有病例治疗后随访2~4次,随访时间15~210 d(平均112.5 d).结果 A型IMH 3例,B 型IMH 8例.MSCT主要征象为:11例主动脉壁新月形或环形增厚>5 mm,呈等密度或高密度,无内膜片撕裂及真、假两腔形成;主动脉粥样硬化7例;内膜钙化内移4例;内膜渗漏3例;穿透性溃疡3例.7例完全吸收,2例部分吸收,2例进展成夹层动脉瘤.结论 MSCT能对IMH作出明确的诊断,并可作为IMH随访的重要检查手段,对临床治疗有重要的指导意义.

  8. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  9. Analysis on the value of the multi-slice spiral CT and MRI scanning for applying to the identifying diagnosis of the new and old vertebral compresion fracture

    International Nuclear Information System (INIS)

    Huo Zhiyi; Gao Shuming; Li Dasheng; Pei Lijun; Qu Hui

    2008-01-01

    Objective: To analyze and explore the value of the mutislice spiral CT (MSCT) scanning, its reconstructive technology and MRI scanning for applying to the identifying diagnosis of new and old vertebral compresion fracture. Methods: One hundred and sixty-seven cases with the new and old vertebral compresion fracture who have 189 vertebrae in total were examined using the MSCT scanning, their imaging information were postprocessed with 2D and 3D reconstruction at the work station. Thirty-four patients with overall 43 vertebrae were carried out by MRI scanning and their images were compared with those of MSCT. Results: They had the highest proportion of vertebrae in L1 with accounting for 27.68% (31/112) and 35.06% (27/77) among the patients with new and old vertebral compresion fracture, respectively. The next was T12, L2 and T11. There were statistically significant differences between new and old cases in such appearance as fracture line clear and sharp (102 and 21), contusion and hemorrhage of spinal cord (15 and 0), parenchyma shadow beside vertebrae(103 and 11), appendant fracture(26 and 5), organ's lacerated wound around vertebral body (30 and 0), discus intervertebrales vacuum (10 and 36), derangement and hardening of vertebral bone trabecularism (29 and 51) (P 1 WI signal, 27 vertebrae with the T 2 WI fat-suppresion irregular high signal were demonstrated in MRI scanning among 27 vertebrae of 21 cases with new vertebral compresion fracture. While 16 vertebrae with the T 1 WI and T 2 WI signals were the same as those of the normal vertebrae, 16 vertebrae were the T 2 WI fat-suppresion low signal among 13 cases with old vertebral compresion fracture. Conclusions: The MSCT plays an important role in identifying diagnosis for the most of the patients with the new and old vertebral compresion fracture, while MRI scanning may reflect the pathophysiological characteristics in diagnosis of the spinal cord and the ligament lesion. Therefore, the MSCT and MRI scanning

  10. Automatic extraction of left ventricular mass and volumes using parametric images from non-ECG-gated 15O-water PET/CT

    DEFF Research Database (Denmark)

    Nordström, J; Harms, Hans; Lubberink, Mark

    of the present study was to investigate the feasibility of measuring LV geometry using dynamic 15O-water PET/CT without ECG-gating. Methods: Parametric images of MBF, perfusable tissue fraction (PTF) and LV blood pool were generated automatically using kinetic modelling. Segmentation of the LV wall using PTF......Introduction: 15O-water positron emission tomography (PET) is considered the gold standard for non-invasive quantification of myocardial blood flow (MBF). It has been shown to identify patients with significant coronary artery disease (CAD) with high accuracy. Hypertrophy with or without dilatation...... combined to measure stroke volume (SV=EDV-ESV) and ejection fraction (EF=SV/EDV). Accuracy was determined by comparing PET to cardiac magnetic resonance (CMR) in 30 asymptomatic patients with high grade LV regurgitation (group A). Precision was determined as inter-observer variation in group...

  11. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    Science.gov (United States)

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (panalysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  12. Diagnostic value of early post-exercise 99Tcm-MIBI ECG-gated myocardial perfusion imaging in severe coronary artery disease

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Feng Jianlin; Cheng Xu; Li Xinli; Cao Kejiang

    2005-01-01

    Objective: To study and compare the diagnostic value in severe coronary artery disease (CAD) of 99 Tc m -methoxyisobutylisonitrile (MIBI) electrocardiogram (ECG)-gated early post-exercise myocardial perfusion imaging (G-MPI) with that of non-ECG-gated myocardial perfusion imaging (NG-MPI). Methods: Two hundred and fifteen suspected CAD patients had undergone G-MPI and coronary artery angiography (CAG) within one month were enrolled and distributed into three-vessel and non-three-vessel CAD groups according to CAG results (≥70%); the diagnostic values in severe CAD of G-MPI and NG-MPI were gained and compared to determine which one of the two protocols would be superior in identification of severe three-vessel CAD. Results: When the ≥70% diameter stenosis CAG was the diagnostic standard of severe CAD, the sensitivity of G-MPI and NG-MPI in the diagnosis of severe CAD were 95.3% (143/150) and 90.7% (136/150, χ 2 =2.509, P=0.113), but when the comparison specifically pinpointed to severe three-vessel CAD, there was significant difference between G-MPI [100%(51/51)] and NG-MPI [92.2% (47/51), χ 2 =4.163, P=0.041]. Diagnostic specificity of G-MPI was 80.0% and that of NG-MPI was 72.3% (χ 2 =1.059, P=0.303). Conclusions: The incremental diagnostic sensitivity of G-MPI adding to the NG-MPI in the diagnosis of severe CAD was mainly from the three-vessel subgroup patients. Exercise stress G-MPI has better diagnostic value in severe three-vessel CAD patients than NG-MPI. (authors)

  13. Prospective versus retrospective ECG gating for dual source CT of the coronary stent: Comparison of image quality, accuracy, and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Lei, E-mail: zhaolei219@sohu.com [Beijing Anzhen Hospital of the Capital University of Medical Sciences (China); Zhang Zhaoqi; Fan Zhanming; Yang Lin; Du Jing [Beijing Anzhen Hospital of the Capital University of Medical Sciences (China)

    2011-03-15

    Objective: To compare image quality, diagnostic accuracy and radiation dose of prospective and retrospective electrocardiogram (ECG) gated dual source computed tomography (DSCT) for the evaluation of the coronary stent, using conventional coronary angiography (CA) as a standard reference. Design, setting and patients: Sixty patients (heart rates {<=}70 bpm) with previous stent implantation who were scheduled for CA were divided in two groups, receiving either prospective or retrospective ECG gated DSCT separately. Two reviewers scored coronary stent image quality and evaluated stent lumen. Results: There was no significant difference in image quality between the two groups. In the prospective group, there were 86.4% (51/59) stents with interpretable images, in the retrospective group, there were 87.5% (49/56) stents with interpretable images. Image quality was not influenced by age, body mass index or heart rate in either group, but heart rate variability had a weak impact on the image quality of the prospective group. Image noise was higher in the prospective group, but this difference reached statistical significance only by using a smooth kernel reconstruction. Per-stent based sensitivity, specificity, and positive and negative predictive value were 100%, 84.1%, 68.2%, and 100%, respectively, in the prospective CT angiography group and 94.4%, 86.8%, 77.3%, and 97.1%, respectively, in the retrospective CT angiography group. There was a significant difference in the effective radiation dose between the two groups, mean effective dose in the prospective and retrospective group was 2.2 {+-} 0.5 mSv (1.5-3.2 mSv) and 14.6 {+-} 3.3 mSv (10.0-20.4 mSv) (p < .001) respectively. Conclusions: Compared with retrospective CT angiography, prospective CT angiography has a similar performance in assessing coronary stent patency, but a lower effective dose in selected patients with regular heart rates {<=}70 bpm.

  14. Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit

    International Nuclear Information System (INIS)

    Greuter, Marcel J.W.; Dorgelo, Joost; Tukker, Wim G.J.; Oudkerk, Matthijs

    2005-01-01

    Acquisition time plays a key role in the quality of cardiac multidetector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of coronary arteries of an anthropomorphic adjustable moving heart phantom on an ECG-gated MDCT unit. The heart phantom and a coronary artery phantom were used on a MDCT unit with a rotation time of 500 ms. The movement of the heart was determined by analysis of the images taken at different phases. The results indicate that the movement of the coronary arteries on the heart phantom is comparable to that in a clinical setting. The influence of the heart rate on image quality and artifacts was determined by analysis of several heart rates between 40 and 80 bpm where the movement of the heart was synchronized using a retrospective ECG-gated acquisition protocol. The resulting reformatted volume rendering images of the moving heart and the coronary arteries were qualitatively compared as a result of the heart rate. The evaluation was performed on three independent series by two independent radiologists for the image quality of the coronary arteries and the presence of artifacts. The evaluation shows that at heart rates above 50 bpm the influence of motion artifacts in the coronary arteries becomes apparent. In addition the influence of a dedicated multisector reconstruction technique on image quality was determined. The results show that the image quality of the coronary arteries is not only related to the heart rate and that the influence of the multisector reconstruction technique becomes significant above 70 bpm. Therefore, this study proves that from the actual acquisition time per heart cycle one cannot determine an actual acquisition time, but only a mathematical acquisition time. (orig.)

  15. Prognostic significance of stress myocardial ECG-gated perfusion imaging in asymptomatic patients with diabetic chronic kidney disease on initiation of haemodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Mitsuru; Kondo, Chisato; Kobayashi, Hideki; Kusakabe, Kiyoko [Tokyo Women' s Medical University, School of Medicine, Department of Radiology, Shinjuku-ku, Tokyo (Japan); Babazono, Tetsuya [Tokyo Women' s Medical University, School of Medicine, Diabetes Centre, Shinjuku-ku, Tokyo (Japan); Nakajima, Takatomo [Tokyo Women' s Medical University, School of Medicine, Department of Cardiology, Shinjuku-ku, Tokyo (Japan)

    2009-08-15

    Diabetic patients with chronic kidney disease (CKD) frequently develop cardiac events within several years of the initiation of haemodialysis. The present study assesses the prognostic significance of stress myocardial ECG-gated perfusion imaging (MPI) in patients with diabetic CKD requiring haemodialysis. Fifty-five asymptomatic patients with diabetic stage V CKD and no history of heart disease scheduled to start haemodialysis were enrolled in this study (56{+-}11 years old; 49 with type 2 diabetes mellitus). All patients underwent {sup 201}Tl stress ECG-gated MPI 1 month before or after the initiation of haemodialysis to assess myocardial involvement. We evaluated SPECT images using 17-segment defect scores graded on a 5-point scale, summed stress score (SSS) and summed difference scores (SDS). The patients were followed up for at least 2 years (42{+-}15 months) to determine coronary intervention (CI) and heart failure (HF) as soft events and acute myocardial infarction (AMI) and all causes of deaths as hard events. The frequencies of myocardial ischaemia, resting perfusion defects, low ejection fraction and left ventricular (LV) dilatation were 24,20,29 and 49%, respectively. Ten events (18%) developed during the follow-up period including four CI, one HF, one AMI and four sudden deaths. Multivariate Cox analysis selected SDS (p=0.0011) and haemoglobin A{sub 1c} (HbA{sub 1c}) (p=0.0076) as independent prognostic indicators for all events. Myocardial ischaemia, in addition to glycaemic control, is a strong prognostic marker for asymptomatic patients with diabetic CKD who are scheduled to start haemodialysis. Stress MPI is highly recommended for the management and therapeutic stratification of such patients. (orig.)

  16. Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the same radiation dose: Comparison of motion artifacts, diagnostic confidence and signal-to-noise-ratios

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger E.; Stadler, Alfred; Beitzke, Dietrich; Homolka, Peter; Weber, Michael; Lammer, Johannes; Czerny, Martin; Loewe, Christian

    2012-01-01

    Purpose: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). Materials and methods: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. Results: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p < 0.001) and DC (p < 0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p < 0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p < 0.001), but not a statistically significant higher DC (p = 0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p = 0.861 and 0.526, respectively) and DC (p = 1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24 mSv; range, 18.43–25.94 mSv) did not differ significantly (p = 0.051) from that of non-gated CT angiography (24.28 mSv; range, 19.37–29.27 mSv). Conclusion: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.

  17. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  18. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  19. Evaluation by means of ECG-gated cardiac blood pool scintigraphy of global and regional left ventricular function at rest and during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Sauer, E.; Sebening, H.; Lutilsky, L.; Dressler, H.; Hoer, G.; Pabst, H.W.; Bloemer, H.; Technische Univ. Muenchen

    1978-01-01

    ECG-gated cardiac blood pool scintigraphy permits a non-invasive determination of the end-diastolic and end-systolic ventricular volumens and of the ejection fraction as well as a qualitative description of regional ventricular wall motion at rest and during exercise. In 6 healthy persons a significant increase of the ejection fraction from 66 +- 7% at rest to 78 +- 3% during exercise (p [de

  20. Evaluation of left ventricular function in patients with atrial fibrillation by ECG gated blood pool scintigraphy. Using frame count normalization method

    Energy Technology Data Exchange (ETDEWEB)

    Akanabe, Hiroshi; Oshima, Motoo; Sakuma, Sadayuki

    1988-07-01

    The assumption necessary to perform ECG gated blood pool scintigraphy (EGBPS) are seemingly not valid for patients with atrial fibrillation (af), since they have wide variability in cardiac cycle length. The data were acquired in frame mode within the limits of mean heart rate of fix the first diastolic volume, and were calculated by frame count normalization (FCN) method to correct total counts in each frame. EGBPS were performed twelve patients with af, who were operated against valvular disease. The data acquired within mean heart rate +-10 % in frame mode were divided to 32 frames, and calculated total frame counts. With FCN method total frame counts from at 22nd to 32nd frame were multiplied to be equal to the average of total frame counts. FCN method could correct total frame counts at the latter frames. And there was good correlation between left ventricular ejection fraction calculated from scintigraphy and that from contrast cineangiography. Thus EGBPS with FCN method may be allow estimation of cardiac function even in subjects with af.

  1. Evaluation of left ventricular function in patients with atrial fibrillation by ECG gated blood pool scintigraphy. Analysis of left ventricular filling and function curve

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu; Adachi, Haruhiko; Sugihara, Hiroki

    1985-12-01

    ECG gated blood pool scintigraphy (EGBP) is not always valid for the patients with atrial fibrillation (AF), since they have wide variability in cardiac cycle length (CL). To evaluate the left ventricular (LV) function during AF by EGBP, we devised a new processing algorithm to construct multiple gated images discriminated by preceding R-R interval (PRR) from the data acquired in list mode. 18 patients with AF were studied as to; 1) How affect the PRR on cardiac indices such as EF, TES, PER or TPER, 2) Comparison with conventional method getting all CL data, 3) LV filling curves derived by plotting EDV against PRR, 4) The slope and position of LV function curves (LVFC) derived by plotting SV against EDV. In most cases, EF, PER and TES were increased with longer PRR, and those by conventional method nearly corresponded to the average values obtained by our new method. Impairment of ventricular filling was demonstrated in the cases of mitral stenosis and constrictive pericarditis. LVFC of CHF group was situated at right and downward to controls, and left and upward shift was observed after treatment. The slope of LVFC was reduced in relation to the progression of NYHA's functional class. In conclusion, this new algorithm processing irregular CL enables LV filling and function curves to draw, which are useful in the evaluation of cardiac performance in the subjects with AF.

  2. Diagnosis of accessory conduction pathway using ECG-gated emission CT analysis. Studies in patients with WPW syndrome who underwent surgery

    Energy Technology Data Exchange (ETDEWEB)

    Misaki, Takuro; Mukai, Keiichi; Tsubota, Makoto; Iwa, Takashi; Nakajima, Ken-ichi; Hisada, Kin-ichi

    1987-09-01

    Pinpointing the location of accessory conduction pathway (ACP) is of great importance in the surgical treatment for Wolff-Parkinson-White (WPW) syndrome. For this purpose, this study explored the usefulness of ECG-gated emission computed tomography (Gated-ECT) in 30 patients who preoperatively underwent Gated-ECT. The site of earliest contraction at level of atrioventicular valves, obtained on tomographic phase analysis, was compared with the site of earliest activation, obtained on epicardial mapping during surgery. The concordance rate of the two methods was 94 % (28/30). Among them, one patient was found to have the association of corrected transposition of great arteries on Gated-ECT. Gated-ECT was, however, of limited value in differentiating right posterior ACP from right postseptal ACP. The discordance between the sites of earliest contraction and activation, which was observed in the two others, was likely due to decreased wall motion resulting from myocardial disturbance. Gated-ECT may have a diagnostic potential for the location of ACP, especially in view of providing images that corresponded to the surgical anatomy. (Namekawa, K.).

  3. Safety and efficacy of a drug regimen to control heart rate during 64-slice ECG-gated coronary CTA in children

    International Nuclear Information System (INIS)

    Rigsby, Cynthia K.; Nicholas, Angela C.; deFreitas, R.A.; Leidecker, Christianne; Johanek, Andrew J.; Anley, Peter; Wang, Deli; Uejima, Tetsu

    2010-01-01

    The adult practice for ECG-gated single-source 64-slice coronary CTA (CCTA) includes administering beta-blockers to reduce heart rate. There are limited data on this process in children. To evaluate the safety and efficacy of a drug regimen to decrease heart rate before performing CCTA in children. IV remifentanil and esmolol infusion were chosen to decrease heart rate in 41 children (mean age 6.5 years) while they were under general anesthesia (GA) for CCTA. Drug doses, changes in heart rate and procedural complications were recorded. CCTA image quality was graded on a scale of 1 to 5. The relationships between image quality and heart rate and image quality and age were evaluated. Patient effective radiation doses were calculated. Heart rates were lowered utilizing esmolol (4 children), remifentanil (2 children) or both (35 children); 26 children received nitroglycerin for coronary vasodilation. The mean decrease in heart rate was 26%. There were no major complications. The average image-quality score was 4.4. Higher heart rates were associated with worse image quality (r = 0.67, P < 0.0001). Older age was associated with better image quality (r = 0.66, P < 0.0001). Effective radiation doses were 0.7 to 7.0 mSv. Heart rate reduction for pediatric CCTA can be safely and effectively achieved while yielding high-quality images. (orig.)

  4. Computer-based automated left atrium segmentation and volumetry from ECG-gated coronary CT angiography data. Comparison with manual slice segmentation and ultrasound planimetric methods

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, R.W.; Kraus, B.; Kerl, J.M.; Lehnert, T.; Vogl, T.J. [Universitaetsklinikum Frankfurt (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Bernhardt, D.; Vega-Higuera, F. [Siemens AG, Healthcare Sector, Forchheim (Germany). Computed Tomography; Ackermann, H. [Universitaetsklinikum Frankfurt (Germany). Inst. fuer Biostatistik und Mathematische Modellierung

    2010-12-15

    Purpose: Enlargement of the left atrium is a risk factor for cardiovascular or cerebrovascular events. We evaluated the performance of prototype software for fully automated segmentation and volumetry of the left atrium. Materials and Methods: In 34 retrospectively ECG-gated coronary CT angiography scans, the end-systolic (LAVsys) and end-diastolic (LAVdia) volume of the left atrium was calculated fully automatically by prototype software. Manual slice segmentation by two independent experienced radiologists served as the reference standard. Furthermore, two independent observers calculated the LAV utilizing two ultrasound planimetric methods ('area length' and 'prolate ellipse') on CTA images. Measurement periods were compared for all methods. Results: The left atrial volumes calculated with the prototype software were in excellent agreement with the results from manual slice segmentation (r = 0.97 - 0.99; p < 0.001; Bland-Altman) with excellent interobserver agreement between both radiologists (r = 0.99; p < 0.001). Ultrasound planimetric methods clearly showed a higher variation (r = 0.72 - 0.86) with moderate interobserver agreement (r = 0.51 - 0.79). The measurement period was significantly lower with the software (267 {+-} 28 sec; p < 0.001) than with ultrasound methods (431 {+-} 68 sec) or manual slice segmentation (567 {+-} 91 sec). Conclusion: The prototype software showed excellent agreement with manual slice segmentation with the least time consumption. This will facilitate the routine assessment of the LA volume from coronary CTA data and therefore risk stratification. (orig.)

  5. Abnormal intraluminal signal within the pulmonary arteries on MR imaging: Differentiation between slow blood flow and thrombus using an ECG-gated; multiphasic: Spin-echo technique

    International Nuclear Information System (INIS)

    White, R.D.; Higgins, C.B.

    1986-01-01

    The authors evaluated abnormal MR imaging signal patterns in the pulmonary arteries of 22 patients with pulmonary hypertension (n = 13), pulmonary embolus (n = 4), or both (n = 5). Using multiphasic (five or six phases; 19 patients) or standard (three patients with pulmonary embolus) ECG-gated, double spin-echo techniques, they were able to differentiate between causes of such abnormal signal patterns. The pattern of slow blood flow (abnormal signal in systole with fluctuating distribution during cardiac cycle, and intensity increasing visually from first to second echo) was noted in 89% of patients with pulmonary hypertension alone or in combination with pulmonary embolism, and was characteristic of high systolic pulmonary pressures (12 of 12 patients with pressure > 80 mm Hg, vs. 3 of 5 patients with pressure 55 mm Hg vs. 5 of 7 patients with pressures <55 mm Hg). This pattern was differentiated from that of thrombus (persistent signal with fixed distribution during cardiac cycle, and little to no visible intensity change from first to second echo), which was noted in six of seven proved embolus cases. Thus, gated multiphase MR imaging shows potential for the noninvasive visualization of pulmonary embolus and the differentiation of this entity from the slow blood flow of pulmonary hypertension

  6. Assessment of automatic quantification of myocardial perfusion and left ventricular function derived from ECG gated myocardial SPECT with {sup 99m}Tc-tetrofosmin in ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Mitsunori; Habara, Hirokazu; Tatsuno, Hironari; Fukuda, Hiroshi; Hamada, Noriko; Kazatani, Yukio [Ehime Prefectural Central Hospital (Japan)

    1999-09-01

    Non-invasive assessment of ischemic heart disease (IHD) requires information of both myocardial perfusion and left ventricular (LV) function. Recently, automatic quantification of ECG-gated myocardial scintigraphy with {sup 99m}Tc-tetrofosmin (QGS) can provide both of them. QGS, coronary angiograms (CAG) and left venticulograms (LVG) were performed in 83 patients with severe IHD in same period. Significant stenosis of coronary artery in CAG were assessed by QGS. The sensitivity, specificity and accuracy of significant stenosis by QGS was excellent (85%, 93% and 88%). The LV end-distolic and end-systolic volumes (EDV and ESV), LV ejection fraction (EF) and regional LV wall motion determined by QGS were compared to LVG. There was a good correlation between the values obtained from QGS and LVG (EDV: r=0.86, ESV: r=0.94, EF: r=0.84, p<0.0001), but QGS tended to underestimate EDV and EF. High complete agreement of regional LV wall motion was gained with 427 (74.0%) out of total 581 segments. In conclusion, QGS data was considered to be useful for assessment of determine significant stenosis and LV function in severe IHD. (author)

  7. [Comparison of radiation dose reduction of prospective ECG-gated one beat scan using 320 area detector CT coronary angiography and prospective ECG-gated helical scan with high helical pitch (FlashScan) using 64 multidetector-row CT coronary angiography].

    Science.gov (United States)

    Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi

    2010-12-20

    A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.

  8. Assessment of left ventricular function in patients with atrial fibrillation by left ventricular filling and function curves determined by ECG gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Suetsugu

    1986-06-01

    Accurate cardiac function in patients with atrial fibrillation (Af) is difficult to assess, since a wide fluctuation of cardiac cycle makes the ventricular hemodynamics variable. Although ECG gated blood pool scintigraphy (EGBPS) is useful to evaluate left ventricular (LV) function, a conventional EGBPS might have a problem in applying to Af. Therefore, a new processing algorithm was devised to make multiple gated images discriminated by preceding R-R intervals (PRR), and LV filling and function curves were obtained in 62 patients with Af to evaluate LV function. LV filling curve, obtained by plotting end-diastolic volume (EDV) againt PRR, demonstrated that the blood filling was impaired in mitral stenosis and constrictive pericarditis, but recovered after mitral commissurotomy. LV function curve, by plotting stroke volume (SV) againt EDV, was quantitatively analysed by the indices such as Slope and Position. Both indices reduced significantly in heart failure. When compared among underlying diseases individually, the indices decreased in the following order; lone Af, hyperthyroidism, senile Af, hypertension, mitral valve disease, ischemic heart disease, dilated cardiomyopathy and aortic regurgitation. After the treatment with digitalis and/or diuretics, left and upward shift of function curve was observed. The rise in heart rate by atropine infusion made Slope and Position unchanged, and which implied that function curve was little influenced by heart rate per se. The rise in systolic blood pressure by angiotensin-II infusion caused shifts in function curve to rightward and downward. Downward shift, mostly seen in patients with gentler slope in control state, may imply afterload mismatch due to a decrease in preload reserve. (J.P.N.).

  9. Quantitative evaluation of renal dynamic scan with 99mTc-MAG3 assessment of interoposterior myocardial infarction using ECG gated SPECT with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Cho, Keiichi; Kumita, Shinichiro; Mizumura, Sunao

    1997-01-01

    Simultaneous assessment of regional myocardial perfusion and local contraction ability of interoposterior myocardial infarction was examined by ECG gated SPECT. In thirteen cases of acute interoposterior myocardial infarction, the above-mentioned data were obtained by 180deg data acquisition method using L-shaped 2 detecting element type gamma camera. Mean and standard deviation of %Uptake and wall thickening (WT) in inferior wall were as follows: Infarction case; 57±9.2%/23±11.3%, normal case; 71±8.2%/61±10.2%. The significant depression (p<0.01/p<0.001) of both data were found in the infarction case. The both data in posterior wall were as follows: Infarction case; 55±10.7%/16±8.9%, normal case; 64±9.7%/41±15.0%. The significant depression (p<0.05/p<0.001) were also found in the infarction case. In both inferior wall and posterior wall, the AUC of ROC curve of WT was greater than that of %Uptake, and diagnostic ability of this method was favorable. The best sensitivity/specificity rate and the threshold were as follows: %Uptake of inferior wall 77/65, -0.5SD, WT of inferior wall 100/100, -2SD, %Uptake of posterior wall 62/82, -1SD, WT of posterior wall 85/88, -4SD. Accordingly, in diagnosis of interoposterior myocardial infarction, assessment of focus cardiac function, for example WT, is necessary as well as %Uptake. (K.H.)

  10. Identification and Assessment of Paradoxical Ventricular Wall Motion Using ECG Gated Blood Pool Scan - Comparison of cine Loop , Phase Analysis and Paradox Image -

    International Nuclear Information System (INIS)

    Lee, Jae Tae; Kim, Gwang Weon; Lee, Kyu Bo; Chung, Byung Chun; Whang, Kee Suk; Chae, Sung Chul; Paek, Wee Hyun; Cheon, Jae Eun; Lee, Hyong Woo; Chung, Jin Hong

    1990-01-01

    Sixty-four patients with paradoxical ventricular wall motion noticed both in angiocardiography or 2-dimensional echocardiography were assessed by ECG gated blood pool scan (GBPS). Endless cine loop image, phase and amplitude images and paradox image obtained by visual inspection of each cardiac beat or Fourier transformation of acquired raw data were investigated to determine the incremental value of GBPS with these processing methods for identification of paradoxical ventricular wall motion. The results were as follows:1) Paradoxical wall motions were observed on interventricular septum in 34 cases, left ventricular free wall in 26 and right ventricular wall in 24. Underlying heart diseases were is chemic (23 cases) valvular(9), congenital heart disease (12), cardiomyopathy (5), pericardial effusion(5), post cardiac surgery(3), corpulmonale (2), endocarditis (l) and right ventricular tumor(l). 2) Left ventricular ejection fractions of patients with paradoxical left ventricular wall motion were significantly lower than those with paradoxical septal motion (p <0.005). 3) The sensitivity of each processing methods for detecting paradoxical wall motion was 76.9% by phase analysis, 74.6% by endless cine loop mapping and 68.4% by paradox image manipulation respectively. Paradoxial motions visualized only in phase, paradox or both images were appeared as hypokinesia or akinesia in cine loop image. 4) All events could be identified by at least one of above three processing methods, however only 34 cases (48.4%) showed the paradoxical motions in all of the three images. By these findings, we concluded that simultaneous inspection of all above three processing methods-endless cine loop, phase analysis and paradox image is necessary for accurate identification and assessment of paradoxical ventricular wall motion when performing GBPS.

  11. Non-enhanced 3D MR angiography of the lower extremity using ECG-gated TSE imaging with non-selective refocusing pulses. Initial experience

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Blondin, D.; Orzechowski, D.; Scherer, A.; Moedder, U.; Kroepil, P.; Godehardt, E.

    2010-01-01

    Purpose: To evaluate non-enhanced 3D MR angiography using turbo spin echo (TSE) imaging with non-selective refocusing pulses (NATIVE SPACE MRA) for the visualization of the arteries of the lower extremity. Materials and Methods: Three-station imaging (iliac arteries, femoral arteries, arteries of the lower leg) was performed in 8 healthy volunteers and 3 patients with peripheral artery disease (PAD) using a 1.5 T MR scanner. In 8 healthy volunteers, 4 different acquisition schemes were performed with the following imaging parameters: S 1: acquisition with every heartbeat (RR = 1), spoiler gradient of 25 % (SG = 25 %); S 2: RR = 1, SG = 0 %; S 3: RR = 2, SG = 25 %; S 4: RR = 2, SG = 0 %. The subjective image quality on a 4-point-scale (4 = excellent to 1 = not diagnostic) and relative SNR were assessed. In 3 patients with peripheral artery disease (PAD), SPACE MRA was performed for assessment of stenosis. Results: The mean subjective image quality was significantly lower for the iliac arteries compared to the femoral arteries and arteries of the lower leg (p < 0.0001). The subjective image quality for acquisition scheme S 1 was significantly lower than the image quality for S 3 and S 4 for the iliac arteries (p < 0.01), while the subjective image quality for acquisition scheme S 2 was significantly lower than S 3 and S 4 for the femoral arteries and the arteries of the lower leg (p < 0.01). The relative SNR was significantly higher for acquisition schemes S 3 and S 4 as compared to S 1 and S 2 (p < 0.0001) for all regions. SPACE MRA disclosed 7 significant stenoses in 3 PAD patients. Conclusion: ECG-gated SPACE MRA is a promising imaging technique for non-enhanced assessment of the arteries of the lower extremity. (orig.)

  12. Identification and Assessment of Paradoxical Ventricular Wall Motion Using ECG Gated Blood Pool Scan - Comparison of cine Loop , Phase Analysis and Paradox Image -

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Tae; Kim, Gwang Weon; Lee, Kyu Bo; Chung, Byung Chun; Whang, Kee Suk; Chae, Sung Chul; Paek, Wee Hyun; Cheon, Jae Eun [Kyungpook National University School of Medicine, Daegu (Korea, Republic of); Lee, Hyong Woo; Chung, Jin Hong [Yeongnam National University College of Medicine, Daegu (Korea, Republic of)

    1990-07-15

    Sixty-four patients with paradoxical ventricular wall motion noticed both in angiocardiography or 2-dimensional echocardiography were assessed by ECG gated blood pool scan (GBPS). Endless cine loop image, phase and amplitude images and paradox image obtained by visual inspection of each cardiac beat or Fourier transformation of acquired raw data were investigated to determine the incremental value of GBPS with these processing methods for identification of paradoxical ventricular wall motion. The results were as follows:1) Paradoxical wall motions were observed on interventricular septum in 34 cases, left ventricular free wall in 26 and right ventricular wall in 24. Underlying heart diseases were is chemic (23 cases) valvular(9), congenital heart disease (12), cardiomyopathy (5), pericardial effusion(5), post cardiac surgery(3), corpulmonale (2), endocarditis (l) and right ventricular tumor(l). 2) Left ventricular ejection fractions of patients with paradoxical left ventricular wall motion were significantly lower than those with paradoxical septal motion (p <0.005). 3) The sensitivity of each processing methods for detecting paradoxical wall motion was 76.9% by phase analysis, 74.6% by endless cine loop mapping and 68.4% by paradox image manipulation respectively. Paradoxial motions visualized only in phase, paradox or both images were appeared as hypokinesia or akinesia in cine loop image. 4) All events could be identified by at least one of above three processing methods, however only 34 cases (48.4%) showed the paradoxical motions in all of the three images. By these findings, we concluded that simultaneous inspection of all above three processing methods-endless cine loop, phase analysis and paradox image is necessary for accurate identification and assessment of paradoxical ventricular wall motion when performing GBPS.

  13. Assessment of left ventricular filling in various heart disease, especially in ischemic heart disease, by ECG-gated cardiac blood pool scintigraphy

    International Nuclear Information System (INIS)

    Nakagawa, Hiroaki

    1986-01-01

    Using ECG-gated cardiac blood pool scintigraphy (BPS), left ventricular (LV) diastolic function was evaluated in various heart disease, especially in ischemic heart disease (IHD). LV function indices (2 systolic and 9 diastolic) were obtained from LV time activity curve derived from BPS. Among various diastolic indices, peak filling rate (PFR) and 2 other indices were significantly influenced by heart rate (HR), so corrected values for HR were used for this study. Various degrees of disturbance in diastolic filling were found in many cases without systolic impairment. According to the mechanism responsible for diastolic impairment, LV time activity curve showed a characteristic pattern. In IHD, filling disturbance in early diastole was observed before the impairment of systolic contraction developed, so it was thought to be an early predictor of cardiac failure. In the scar region of myocardial infarction (MI), decrease in regional ejection fraction and asynchrony in wall motion were shown, and these resulted in marked deterioration of early diastolic filling. On the other hand in angina pectoris (AP), such systolic disorders were not shown in the ischemic region perfused by stenotic coronary artery, although the disturbance of regional filling was found. The exercise capacity in AP was more related to the impairment in diastolic function at resting state than in systolic function, and furthermore the reserve of diastolic function as well as of systolic function was shown to be an important determinant of exercise capacity in AP. As HR increased, increase of PFR and decrease in time to peak filling was found, which was thought to be a sort of compensation for the shortening diastolic time due to increase in HR during exercise. Such compensation was decreased in AP with reduced exercise capacity. (J.P.N.)

  14. Diagnostic accuracy of coronary angiography with multislice computed tomography applied to 'the Real World'

    International Nuclear Information System (INIS)

    Rodriguez Granillo, Gaston A.; Rosales, Miguel A.; Llaurado, Claudio; Fernandez Pereira, Carlos; Garcia Carcia, Hector M.

    2006-01-01

    Objective: To assess the diagnostic accuracy of Coronary Angiography with Multislice Computed Tomography (MSCT) for the detection of significant coronary artery stenoses. Material and methods: Patients studied had an indication for diagnostic coronary angiography and no history of contrast allergies, renal failure or arrhythmias. A multislice tomography equipment (Brilliance 40, Philips, The Netherlands) with ECG gating was used for image acquisition. A total of 90-125 mI of iodinated contrast was administered by IV route. Obesity, diabetes, diffusely calcified segments with a diameter < 2.0 mm, and segments treated with stents were not considered exclusion criteria. Lesions were defined as significant when the decrease in Iumen was ≥ 50% by MSCT and quantitative coronary angiography (QCA). Results: A total of 38 patients were scanned before the intervention. Of them, one (3%) was excluded because of inadequate image quality. The remaining 37 patients (444 segments), with an adequate quality image, were included in the study (81% men, mean age 62.43 ± 12.5 years, 13.5% diabetics). Mean scan time was 15.12 ± 2.6 seconds, and 444 segments were assessed with both techniques. The number of lesions deemed significant by QCA and MSCT were 88 (17%) and 93 (18%), respectively. Sensitivity, specificity, positive and negative predictive values of MSCT to detect significant stenoses were 82%, 93%, 72% and 96%, respectively. Conclusion: In non-selected patients, coronary angiography by multislice computed tomography exhibits a high negative predictive value for the detection of obstructive coronary disease. (author)

  15. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai; Ma, Rui; Wang, Li Jun [Dept. of Radiology, Baotou Central Hospital, Baotou (China); Li, Li Gang; Chen, Jiu Hong [CT BM Clinic Marketing, Siemens Healthcare, Beijing (China)

    2012-11-15

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 {+-} 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 {+-} 0.306 [group A] vs. 1.084 {+-} 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 {+-} 0.16 mSv in group A and 7.1 {+-} 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  16. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    International Nuclear Information System (INIS)

    Sun, Kai; Ma, Rui; Wang, Li Jun; Li, Li Gang; Chen, Jiu Hong

    2012-01-01

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  17. Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun; Fujioka, Chikako; Kiguchi, Masao; Kohno, Shingo [Hiroshima University Hospital, Department of Clinical Radiology, Hiroshima (Japan); Yamamoto, Hideya; Kitagawa, Toshiro [Hiroshima University, Department of Molecular and Internal Medicine, Division of Clinical Medical Science, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan); Ito, Katsuhide [Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan)

    2009-10-15

    The purpose of this study was to compare coronary 64-slice CT angiography (CTA) protocols, specifically prospective electrocardiograph (ECG)-triggered and retrospective ECG-gated CT acquisition performed using a tube voltage of 140 kV and 120 kV, regarding intracoronary stent imaging. Coronary artery stents (n=12) with artificial in-stent restenosis (50% luminal reduction, 40 HU) on a cardiac phantom were examined by CT at heart rates of 50-75 beats per minute (bpm). The subjective visibility of in-stent restenosis was evaluated with a three-point scale (1 clearly visible, 2 visible, and 3 not visible), and artificial lumen narrowing [(inner stent diameter - measured lumen diameter)/inner stent diameter], lumen attenuation increase ratio [(in-stent attenuation - coronary lumen attenuation)/coronary lumen attenuation], and signal-to-noise ratio of in-stent lumen were determined. The effective dose was estimated. The artificial lumen narrowing (mean 43%), the increase of lumen attenuation (mean 46%), and signal-to-noise ratio (mean 7.8) were not different between CT acquisitions (p=0.12-0.91). However, the visibility scores of in-stent restenosis were different (p<0.05) between ECG-gated CTA techniques: (a) 140-kV prospective (effective dose 4.6 mSv), 1.6; (b) 120-kV prospective (3.3 mSv), 1.8; (c) 140-kV retrospective (16.4-18.8 mSv), 1.9; and (d) 120-kV retrospective (11.0-13.4 mSv), 1.9. Thus, 140-kV prospective ECG-triggered CTA improves coronary in-stent restenosis visibility at a lower radiation dose compared with retrospective ECG-gated CTA. (orig.)

  18. Reliability analysis of visual ranking of coronary artery calcification on low-dose CT of the thorax for lung cancer screening: comparison with ECG-gated calcium scoring CT.

    Science.gov (United States)

    Kim, Yoon Kyung; Sung, Yon Mi; Cho, So Hyun; Park, Young Nam; Choi, Hye-Young

    2014-12-01

    Coronary artery calcification (CAC) is frequently detected on low-dose CT (LDCT) of the thorax. Concurrent assessment of CAC and lung cancer screening using LDCT is beneficial in terms of cost and radiation dose reduction. The aim of our study was to evaluate the reliability of visual ranking of positive CAC on LDCT compared to Agatston score (AS) on electrocardiogram (ECG)-gated calcium scoring CT. We studied 576 patients who were consecutively registered for health screening and undergoing both LDCT and ECG-gated calcium scoring CT. We excluded subjects with an AS of zero. The final study cohort included 117 patients with CAC (97 men; mean age, 53.4 ± 8.5). AS was used as the gold standard (mean score 166.0; range 0.4-3,719.3). Two board-certified radiologists and two radiology residents participated in an observer performance study. Visual ranking of CAC was performed according to four categories (1-10, 11-100, 101-400, and 401 or higher) for coronary artery disease risk stratification. Weighted kappa statistics were used to measure the degree of reliability on visual ranking of CAC on LDCT. The degree of reliability on visual ranking of CAC on LDCT compared to ECG-gated calcium scoring CT was excellent for board-certified radiologists and good for radiology residents. A high degree of association was observed with 71.6% of visual rankings in the same category as the Agatston category and 98.9% varying by no more than one category. Visual ranking of positive CAC on LDCT is reliable for predicting AS rank categorization.

  19. MO-DE-207A-06: ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System

    Energy Technology Data Exchange (ETDEWEB)

    Slagowski, JM; Dunkerley, DAP [MA Speidel, University of Wisconsin - Madison, Madison, WI (United States)

    2016-06-15

    Purpose: To obtain ECG-gated CT images from truncated projection data acquired with a C-arm based inverse geometry fluoroscopy system, for the purpose of cardiac chamber mapping in interventional procedures. Methods: Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system with a scanned multisource x-ray tube and a photon-counting detector mounted to a C-arm. In the proposed method, SBDX short-scan rotational acquisition is performed followed by inverse geometry CT (IGCT) reconstruction and segmentation of contrast-enhanced objects. The prior image constrained compressed sensing (PICCS) framework was adapted for IGCT reconstruction to mitigate artifacts arising from data truncation and angular undersampling due to cardiac gating. The performance of the reconstruction algorithm was evaluated in numerical simulations of truncated and non-truncated thorax phantoms containing a dynamic ellipsoid to represent a moving cardiac chamber. The eccentricity of the ellipsoid was varied at frequencies from 1–1.5 Hz. Projection data were retrospectively sorted into 13 cardiac phases. Each phase was reconstructed using IGCT-PICCS, with a nongated gridded FBP (gFBP) prior image. Surface accuracy was determined using Dice similarity coefficient and a histogram of the point distances between the segmented surface and ground truth surface. Results: The gated IGCT-PICCS algorithm improved surface accuracy and reduced streaking and truncation artifacts when compared to nongated gFBP. For the non-truncated thorax with 1.25 Hz motion, 99% of segmented surface points were within 0.3 mm of the 15 mm diameter ground truth ellipse, versus 1.0 mm for gFBP. For the truncated thorax phantom with a 40 mm diameter ellipse, IGCT-PICCS surface accuracy measured 0.3 mm versus 7.8 mm for gFBP. Dice similarity coefficient was 0.99–1.00 (IGCT-PICCS) versus 0.63–0.75 (gFBP) for intensity-based segmentation thresholds ranging from 25–75% maximum contrast. Conclusions: The

  20. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo; Daimon, Tadahisa; Honda, Osamu; Mihara, Naoki; Johkoh, Takeshi; Nakamura, Hironobu

    2009-01-01

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61-0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma

  1. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Daimon, Tadahisa [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Mihara, Naoki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Radiology, Osaka Advanced Medical Imaging Center, 5-20-1 Momoyamadai, Suita-city, Osaka 565-0854 (Japan); Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2009-01-15

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, {kappa} = 0.61-0.71), and fair or poor in the other evaluations ({kappa} < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of

  2. Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Linfeng; Zhou, Tao; Zhang, Ruijie; Peng, Zhaohui; Ding, Juan; Wang, Sen; Li, Min; Sun, Gang [Jinan Military General Hospital, Department of Medical Imaging, Jinan, Shandong Province (China); Xu, Lin [Jinan Military General Hospital, Department of Medical Cardiology, Jinan, Shandong Province (China)

    2014-10-15

    To investigate the diagnostic performance of coronary computed tomographic angiography (CCTA) with prospective electrocardiograph (ECG) gating based on step-and-shoot (SAS), Flash and volume imaging modes. We searched the electronic databases PubMed for all published studies regarding CCTA. We used an exact binomial rendition of the bivariate mixed-effects regression model developed for synthesis of diagnostic data. A total of 21,852 segments, 4,851 vessels and 1,375 patients were identified using database searches. Patient-level pooled sensitivity was 0.99 (95 % confidence interval [CI], 0.98-1.00); specificity was 0.88 (CI, 0.85-0.91). The results showed that the sensitivity and specificity for detection of significant stenosis did not differ in the three protocols (P = 0.24). No heterogeneity was found at the patient level for sensitivity (Q = 26.23; P = 0.12; I {sup 2} = 27.56 % [CI, 0.00-67.02 %]) and specificity (Q = 19.54; P = 0.42; I {sup 2} = 2.78 % [CI, 0.00-66.26 %]). CCTA with prospective ECG gating has similar high diagnostic value to rule out CAD in all three presented modes. (orig.)

  3. Non-enhanced ECG-gated respiratory-triggered 3-D steady-state free-precession MR angiography with slab-selective inversion: initial experience in visualisation of renal arteries in free-breathing children without renal artery abnormality

    International Nuclear Information System (INIS)

    Klee, Dirk; Lanzman, Rotem Shlomo; Blondin, Dirk; Antoch, Gerald; Schaper, Joerg; Schmitt, Peter; Oh, Jun; Salgin, Burak; Mayatepek, Ertan

    2012-01-01

    ECG-gated non-enhanced balanced steady-state free precession (bSSFP) MR angiography requires neither breath-holding nor administration of contrast material. To investigate the image quality of free-breathing ECG-gated non-enhanced bSSFP MR angiography of renal arteries in children. Fourteen boys and seven girls (mean age, 9.7 years; range, 7 weeks-17 years) with no history of renovascular disease were included. MRI was performed at 1.5 T. Subjective image quality of axial and coronal maximum-intensity-projection reconstructions of four segments (I, aorta and renal artery ostium; II, main renal artery; III, segmental branches; IV, intrarenal vessels) was evaluated using a 4-point scale (4 = excellent, 3 = good, 2 = acceptable, 1 = non-diagnostic). Image quality was excellent for segments I (mean ± SD, 3.9 ± 0.3) and II (4.0 ± 0.1), good for segment III (3.4 ± 0.9) and acceptable for segment IV (2.3 ± 1.1). Mean image quality did not differ between sedated and non-sedated children. bSSFP MR angiography enables visualisation of renal arteries in children. (orig.)

  4. Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents

    International Nuclear Information System (INIS)

    Böning, Guido; Todica, Andrei; Vai, Alessandro; Lehner, Sebastian; Xiong, Guoming; Mille, Erik; Ilhan, Harun; Fougère, Christian la; Bartenstein, Peter; Hacker, Marcus

    2013-01-01

    The assessment of left ventricular function, wall motion and myocardial viability using electrocardiogram (ECG)-gated [ 18 F]-FDG positron emission tomography (PET) is widely accepted in human and in preclinical small animal studies. The nonterminal and noninvasive approach permits repeated in vivo evaluations of the same animal, facilitating the assessment of temporal changes in disease or therapy response. Although well established, gated small animal PET studies can contain erroneous gating information, which may yield to blurred images and false estimation of functional parameters. In this work, we present quantitative and visual quality control (QC) methods to evaluate the accuracy of trigger events in PET list-mode and physiological data. Left ventricular functional analysis is performed to quantify the effect of gating errors on the end-systolic and end-diastolic volumes, and on the ejection fraction (EF). We aim to recover the cardiac functional parameters by the application of the commonly established heart rate filter approach using fixed ranges based on a standardized population. In addition, we propose a fully reprocessing approach which retrospectively replaces the gating information of the PET list-mode file with appropriate list-mode decoding and encoding software. The signal of a simultaneously acquired ECG is processed using standard MATLAB vector functions, which can be individually adapted to reliably detect the R-peaks. Finally, the new trigger events are inserted into the PET list-mode file. A population of 30 mice with various health statuses was analyzed and standard cardiac parameters such as mean heart rate (119 ms ± 11.8 ms) and mean heart rate variability (1.7 ms ± 3.4 ms) derived. These standard parameter ranges were taken into account in the QC methods to select a group of nine optimal gated and a group of eight sub-optimal gated [ 18 F]-FDG PET scans of mice from our archive. From the list-mode files of the optimal gated group

  5. Multislice CT coronary angiography: evaluation of an automatic vessel detection tool

    International Nuclear Information System (INIS)

    Dewey, M.; Schnapauff, D.; Lembcke, A.; Hamm, B.; Rogalla, P.; Laule, M.; Borges, A.C.; Rutsch, W.

    2004-01-01

    Purpose: To investigate the potential of a new detection tool for multisliceCT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. Materials and Methods: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (≥50%) in all segments of ≥1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. Results: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94%, 89 vs. 84%, 6 vs. 6%, and 89 vs. 88%, respectively (p=n.s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143±30 vs. 146±24 mm, r=0.923, p [de

  6. Multi-slice Computed Tomography Appearance of Abscess of Cavum Septum Pellucidum: A Case Report and Review of the Literature

    Energy Technology Data Exchange (ETDEWEB)

    Vasudev, M.K.; Chavan, R.G.; Nagarajan, K.; Shukla, D.; Devi, B.I. [National Inst. of Mental Health and Neurosciences, Bangalore (India). Depts. of Neuroimaging and Interventional Radiology and of Neurosurgery

    2006-04-15

    Abscesses involving the cavum septum pellucidum are rare and, owing to their location, detection may be difficult with routine conventional computed tomography (CT). Only a few isolated cases have been reported and mostly in children. We report a case of abscess involving the cavum septum pellucidum in an adult and its appearance on multi-slice spiral CT Abscess, cavum septum pellucidum, multi-slice CT, surgery.

  7. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  8. Comparison of transaxial source images and 3-plane, thin-slab maximal intensity projection images for the diagnosis of coronary artery stenosis with using ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Seo, Joon Beom; Do, Kyung Hyun

    2006-01-01

    We wanted to compare the transaxial source images with the optimized three plane, thin-slab maximum intensity projection (MIP) images from electrocardiographic (ECG)-gated cardiac CT for their ability to detect hemodynamically significant stenosis (HSS), and we did this by means of performing a receiver operating characteristic (ROC) analysis. Twenty-eight patients with a heart rate less than 66 beats per minute and who were undergoing both retrospective ECG-gated cardiac CT and conventional coronary angiography were included in this study. The contrast-enhanced CT scans were obtained with a collimation of 16 x 0.75-mm and a rotation time of 420 msec. The tranaxial images were reconstructed at the mid-diastolic phase with a 1-mm slice thickness and a 0.5-mm increment. Using the transaxial images, the slab MIP images were created with a 4-mm thickness and a 2-mm increment, and they covered the entire heart in the horizontal long axis (4 chamber view), in the vertical long axis (2 chamber view) and in the short axis. The transaxial images and MIP images were independently evaluated for their ability to detect HSS. Conventional coronary angiograms of the same study group served as the standard of reference. Four radiologists were requested to rank each image with using a five-point scale (1 = definitely negative, 2 = probably negative, 3 = indeterminate, 4 = probably positive, and 5 definitely positive) for the presence of HSS; the data were then interpreted using ROC analysis. There was no statistical difference in the area under the ROC curve between transaxial images and MIP images for the detection of HSS (0.8375 and 0.8708, respectively; ρ > 0.05). The mean reading time for the transaxial source images and the MIP images was 116 and 126.5 minutes, respectively. The diagnostic performance of the MIP images for detecting HSS of the coronary arteries is acceptable and this technique's ability to detect HSS is comparable to that of the transaxial source images

  9. Logarithmic Spiral

    Indian Academy of Sciences (India)

    Switzerland) even today can see the. Archimedian spiral and the inscription under it on the tombstone of Jacob Bernoulli 1. Logarithmic Spiral in Nature. Apart from logarithmic spiral no other curve seems to have attracted the attention of scientists, ...

  10. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease. Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yoda, Shunichi; Sato, Yuichi; Matsumoto, Naoya; Tani, Shigemasa; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2005-01-01

    Although the detection of wall motion abnormalities gives incremental value to myocardial perfusion single-photon emission computed tomography (SPECT) in the diagnosis of extensive coronary artery disease (CAD) and high-grade single-vessel CAD, whether or not it is useful in the diagnosis of mild, single-vessel CAD has not been studied previously. Separate acquisition, dual isotope electrocardiogram (ECG)-gated SPECT was performed in 97 patients with a low likelihood of CAD (Group 1) and 46 patients with single-vessel CAD (Group 2). Mild CAD was defined by stenosis of 50-75% (Group 2a, n=22) and moderate to severe CAD was defined by stenosis ≥76% (Group 2b, n=24). Myocardial perfusion and wall motion were graded by a 5 point-scale, 20-segment model. The sensitivity of myocardial perfusion alone was 50% for Group 2a, 83% for Group 2b and 67% for Group 2 as a whole. The overall specificity was 90%. When the wall motion analysis was combined, the sensitivity was increased to 82% in Group 2a and 92% in Group 2b. The ability to detect a wall motion abnormality immediately after exercise gives incremental diagnostic value to myocardial perfusion SPECT in the identification of mild, single-vessel CAD. (author)

  11. Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (''ECG pulsing''): phantom measurements

    International Nuclear Information System (INIS)

    Poll, L.W.; Cohnen, M.; Brachten, S.; Moedder, U.; Ewen, K.

    2002-01-01

    To evaluate the effect of ECG-controlled tube current modulation on radiation exposure in retrospectively-ECG-gated multislice CT (MSCT) of the heart. Material and methods: Three different cardiac MSCT protocols with different slice collimation (4 x 1, and 4 x 2.5 mm), and a pitch-factor of 1.5 and 1.8 were investigated at a multi-slice CT scanner Somatom Volume Zoom, Siemens. An anthropomorphic Alderson-Rando phantom was equipped with LiF-Thermoluminescence dosimeters at several organ sites, and effective doses were calculated using ICRP-weighting factors. Scan protocols were performed with ECG-controlled tube current modulation ('ECG pulsing') at two different heart rates (60 and 80 bpm). These data were compared to previous data from MSCT of the heart without use of 'ECG pulsing'. Results: Radiation exposure with (60 bpm) and without tube current modulation using a 2.5 mm collimation was 1.8 mSv and 2.9 mSv for females, and 1.5 mSv and 2.4 mSv for males, respectively. For protocols using a 1 mm collimation with a pitch-factor of 1.5 (1.8), radiation exposure with and without tube current modulation was 5.6 (6.3) mSv and 9.5 (11.2) mSv for females, and 4.6 (5.2) mSv and 7.7 (9.2) mSv for males, respectively. At higher heart rates (80 bpm) radiation exposure is increased from 1.5-1.8 mSv to 1.8-2.1 mSv, using the 2.5 mm collimation, and from 4.6-5.6 mSv to 5.9-7.2 mSv, for protocols using 1 mm collimation. Conclusions: The ECG-controlled tube current modulation allows a dose reduction of 37% to 44% when retrospectively ECG-gated MSCT of the heart is performed. The tube current - as a function over time - and therefore the radiation exposure is dependent on the heart rate. (orig.) [de

  12. 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram-triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral Scan.

    Science.gov (United States)

    Lin, Lu; Wang, Yi-Ning; Kong, Ling-Yan; Jin, Zheng-Yu; Lu, Guang-Ming; Zhang, Zhao-Qi; Cao, Jian; Li, Shuo; Song, Lan; Wang, Zhi-Wei; Zhou, Kang; Wang, Ming

    2013-01-01

    Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequential scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrillation referred for a second-generation 128-slice DSCT coronary angiography were included in the prospective study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG-triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel-lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each patient were compared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean HR (t=1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by reader1 and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by reader1 and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27±0.19 vs. 1.25±0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively

  13. Multi-slice spiral CT diagnosis of arterial sequestration

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Objective: The purpose of this study was to present the characteristic features on MSCT angiography of arterial sequestration. Methods: The MSCT images of 5 patients with arterial sequestration were retrospectively reviewed. All patients underwent MSCT contrast-enhanced angiography. 3D rendering was made to evaluate the lung parenchyma, bronchial system, and vascular anatomy. Results: All 5 cases demonstrated the anomalous systemic artery (ASA) as an isolated and tortuous artery arising from the descending thoracic aorta, taking a sigmoid course and running along with airway, entering the basal segments of the left lowed lobe. The inferior pulmonary vein (IPV) was significantly engorged. The typical AS was diagnosed in 4 patients. Its ASA intercrossed with the IPV and two branches entering segments 7 and 8 over the IPV, and two branches entering segments 9 and 10 under the IPV. The volume of involved lung shrunk with the artery markedly engorged. A characteristic avascular section was found between the pulmonary artery supplying area and the ASA supplying area, and the bronchi did not accompany the arteries. One was diagnosed atypical AS because of coexistence with bronchial atresia. Conclusion: The arterial sequestration had characteristic MSCT findings. The typical type can be definitely diagnosed, but the atypical type needs further three-dimensional analysis. (authors)

  14. Spiral symmetry

    CERN Document Server

    Hargittai, Istvan

    1992-01-01

    From the tiny twisted biological molecules to the gargantuan curling arms of many galaxies, the physical world contains a startling repetition of spiral patterns. Today, researchers have a keen interest in identifying, measuring, and defining these patterns in scientific terms. Spirals play an important role in the growth processes of many biological forms and organisms. Also, through time, humans have imitated spiral motifs in their art forms, and invented new and unusual spirals which have no counterparts in the natural world. Therefore, one goal of this multiauthored book is to stress the c

  15. Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA

    International Nuclear Information System (INIS)

    Haneder, Stefan; Attenberger, Ulrike I.; Riffel, Philipp; Henzler, Thomas; Schoenberg, Stefan O.; Michaely, Henrik J.

    2011-01-01

    To compare 3D non-enhanced ECG-gated inflow-dependent MRA (NE-MRA) vs. continuous table movement (CTM) MR-angiography and time-resolved TWIST-MRA in the calf station at 3.0 T in a clinical patient collective. 36 patients (27 male/9 female, 66.1 ± 14.4 years) with PAOD (stage II-IV) underwent during a single MRI: NE-MRA, contrast-enhanced CTM-MRA and TWIST-MRA with a single dose of a gadolinium-based contrast agent. The image quality (IQ) and the degree of stenoses were rated on a four-point scale. Positive (PPV) and negative predictive values (NPV), sensitivity (SS) and specificity (SP) for stenoses detection were calculated for NE-MRA vs. CTM-MRA and vs. TWIST-MRA. Values were obtained for overall graduation of wall changes and for severe stenoses (>70%). With NE-MRA 122/288 segments were not assessable. Compared with CTM-MRA and TWIST-MRA the IQ was significantly inferior (p < 0.0001 to p = 0.0426). CTM-MRA/TWIST-MRA detected stenoses in 44.9%/46.1% of the segments, NE-MRA in 53.5%. SS/NPV of the NE-MRA ranged from 97.8 to 100%. The SP and PPV ranged from 72.7 to 85.5% and 66.7 to 78.2%. Contrast-enhanced MRA techniques are superior to NE-MRA regarding IQ and correct identification of stenoses. If technically successful, NE-MRA is characterised by high NPV and overestimation of the degree of stenoses. (orig.)

  16. The amount of viable and dyssynchronous myocardium is associated with response to cardiac resynchronization therapy: initial clinical results using multiparametric ECG-gated [{sup 18}F]FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, Sebastian; Uebleis, Christopher; Haug, Alexander; Bartenstein, Peter [University of Munich, Department of Nuclear Medicine, Munich (Germany); Schuessler, Franziska; Kaeaeb, Stefan; Estner, Heidi [University of Munich, Medical Department I, Munich (Germany); Van Kriekinge, Serge D.; Germano, Guido [UCLA, Cedars-Sinai Medical Center, Los Angeles and David Geffen School of Medicine, Los Angeles, CA (United States); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Theraphy, Vienna (Austria)

    2013-12-15

    There is still a significant amount of patients who do not sufficiently respond to cardiac resynchronization therapy (CRT). Previous studies demonstrated that the amount of dyssynchronous myocardium was predictive of response to CRT. Otherwise, non-response is frequently associated with high amounts of scar tissue. The combination of these parameters might yield a more accurate prediction of response. We hypothesized that the probability of a CRT response increases with the presence of high amounts of ''viable and dyssynchronous'' myocardium. A total of 19 patients (17 male, 61 {+-} 10 years) underwent ECG-gated [{sup 18}F]fluorodeoxyglucose (FDG) myocardial positron emission tomography (PET) before CRT device implantation and were followed for 6 months. Response to CRT was defined as clinical improvement of at least one New York Heart Association (NYHA) class in combination with left ventricular (LV) ejection fraction (EF) improvement of >5 %. Twelve responders (71 %) and seven non-responders (29 %) were identified. For each patient bullseye maps of FDG uptake and phase analysis were calculated (QPS/QGS 2012, Cedars-Sinai, Los Angeles, CA, USA) and fused. Amounts of myocardium representing ''viable and synchronous'', ''scar and synchronous'', viable and dyssynchronous or ''scar and dyssynchronous'' myocardium were quantified by planimetric measurements of the fused bullseye maps. Responders by definition showed significant decrease in NYHA class and significant increase of LVEF. Furthermore, a significantly higher amount of viable and dyssynchronous myocardium was found as compared to non-responders (21 {+-} 13 % vs 6 {+-} 5 %; p < 0.05). Combined assessment of myocardial viability and LV dyssynchrony is feasible using multiparametric [{sup 18}F]FDG PET and could improve conventional response prediction criteria for CRT. (orig.)

  17. 3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients.

    Science.gov (United States)

    Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M

    2016-09-01

    To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.

  18. Surveillance study for creating the national clinical database relating to ECG-gated myocardial perfusion SPECT of asymptomatic ischemic heart disease in patients with type-2 diabetes mellitus. J-ACCESS 2 study design

    International Nuclear Information System (INIS)

    Kusuoka, Hideo; Yamasaki, Yoshimitsu; Izumi, Tohru; Kashiwagi, Atsunori; Kawamori, Ryuzo; Shimamoto, Kazuaki; Yamada, Nobuhiro; Nishimura, Tsunehiko

    2008-01-01

    Diabetes mellitus is an independent risk factor for acute myocardial infarction. Thus, a surveillance study was conducted as part of studies to create a national database related to electrocardiogram (ECG)-gated myocardial perfusion single-photon emission computed tomography (SPECT) of ischemic heart disease. Single-photon emission computed tomography was conducted in patients with type 2 diabetes mellitus and their prognoses will be followed for 3 years, stratified by patients' clinical background and SPECT findings. A total of 513 patients from 50 institutions were enrolled in this study, 297 of whom were men (age 66.2±0.4 years, mean±standard error of the mean (SEM)) and 261 women (age 67.8±0.5 years). They have a history of retinopathy (25.3%), neuropathy (19.9%), cerebrovascular disorder, chronic obstructive pulmonary disease, and photocoagulation. Major risk factors for present disease were hypertension (82.3%) and hyperlipidemia (79.7%). In 244 patients (129 men and 115 women), body mass index (BMI) was 25 or more. Fifty-two of them (10.1%) underwent coronary angiography; of these, 26 (50.0%) had no coronary artery lesions with 75% or more stenosis, and only 1 (1.9%) had a left main trunk with 50% or more stenosis. An overwhelming majority of patients (94.3%) underwent SPECT imaging by a 1-day stress-followed-by-rest procedure. Stress procedure was exercise in most (70.8%) patients, followed by dipyridamole infusion in 14.6%, adenosine infusion in 6.6%, and adenosine triphosphate infusion in 5.7%. Endpoint of stress examination was most often fatigue in lower limbs (40.7%), followed by completion of pharmacological stress protocol (28.7%), and achievement of target heart rate (26.3%). The largest number of patients (198, 38.6%) received 99m Tc-tetrofosmin at an initial dosage of 200-300 MBq (mean 331±3 MBq) followed by a second dosage of 700-800 MBq (mean 748±8 MBq). Among them, 491 (95.7%) received some kind of therapeutic drug: hypoglycemic drugs were

  19. Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.

    Science.gov (United States)

    Bonanno, Gabriele; Hays, Allison G; Weiss, Robert G; Schär, Michael

    2018-08-01

    Depressed coronary endothelial function (CEF) is a marker for atherosclerotic disease, an independent predictor of cardiovascular events, and can be quantified non-invasively with ECG-triggered spiral cine MRI combined with isometric handgrip exercise (IHE). However, MRI-CEF measures can be hindered by faulty ECG-triggering, leading to prolonged breath-holds and degraded image quality. Here, a self-gated golden angle spiral method (SG-GA) is proposed to eliminate the need for ECG during cine MRI. SG-GA was tested against retrospectively ECG-gated golden angle spiral MRI (ECG-GA) and gold-standard ECG-triggered spiral cine MRI (ECG-STD) in 10 healthy volunteers. CEF data were obtained from cross-sectional images of the proximal right and left coronary arteries in a 3T scanner. Self-gating heart rates were compared to those from simultaneous ECG-gating. Coronary vessel sharpness and cross-sectional area (CSA) change with IHE were compared among the 3 methods. Self-gating precision, accuracy, and correlation-coefficient were 7.7 ± 0.5 ms, 9.1 ± 0.7 ms, and 0.93 ± 0.01, respectively (mean ± standard error). Vessel sharpness by SG-GA was equal or higher than ECG-STD (rest: 63.0 ± 1.7% vs. 61.3 ± 1.3%; exercise: 62.6 ± 1.3% vs. 56.7 ± 1.6%, P < 0.05). CSA changes were in agreement among the 3 methods (ECG-STD = 8.7 ± 4.0%, ECG-GA = 9.6 ± 3.1%, SG-GA = 9.1 ± 3.5%, P = not significant). CEF measures can be obtained with the proposed self-gated high-quality cine MRI method even when ECG is faulty or not available. Magn Reson Med 80:560-570, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Frequency spirals

    International Nuclear Information System (INIS)

    Ottino-Löffler, Bertrand; Strogatz, Steven H.

    2016-01-01

    We study the dynamics of coupled phase oscillators on a two-dimensional Kuramoto lattice with periodic boundary conditions. For coupling strengths just below the transition to global phase-locking, we find localized spatiotemporal patterns that we call “frequency spirals.” These patterns cannot be seen under time averaging; they become visible only when we examine the spatial variation of the oscillators' instantaneous frequencies, where they manifest themselves as two-armed rotating spirals. In the more familiar phase representation, they appear as wobbly periodic patterns surrounding a phase vortex. Unlike the stationary phase vortices seen in magnetic spin systems, or the rotating spiral waves seen in reaction-diffusion systems, frequency spirals librate: the phases of the oscillators surrounding the central vortex move forward and then backward, executing a periodic motion with zero winding number. We construct the simplest frequency spiral and characterize its properties using analytical and numerical methods. Simulations show that frequency spirals in large lattices behave much like this simple prototype.

  1. Frequency spirals

    Energy Technology Data Exchange (ETDEWEB)

    Ottino-Löffler, Bertrand; Strogatz, Steven H., E-mail: strogatz@cornell.edu [Center for Applied Mathematics, Cornell University, Ithaca, New York 14853 (United States)

    2016-09-15

    We study the dynamics of coupled phase oscillators on a two-dimensional Kuramoto lattice with periodic boundary conditions. For coupling strengths just below the transition to global phase-locking, we find localized spatiotemporal patterns that we call “frequency spirals.” These patterns cannot be seen under time averaging; they become visible only when we examine the spatial variation of the oscillators' instantaneous frequencies, where they manifest themselves as two-armed rotating spirals. In the more familiar phase representation, they appear as wobbly periodic patterns surrounding a phase vortex. Unlike the stationary phase vortices seen in magnetic spin systems, or the rotating spiral waves seen in reaction-diffusion systems, frequency spirals librate: the phases of the oscillators surrounding the central vortex move forward and then backward, executing a periodic motion with zero winding number. We construct the simplest frequency spiral and characterize its properties using analytical and numerical methods. Simulations show that frequency spirals in large lattices behave much like this simple prototype.

  2. Clinical application of 16-slice spiral CT in reconstruction imaging of coronary artery for diagnosing coronary disense

    International Nuclear Information System (INIS)

    Mao Xinbo; Zhu Xinjin; Zeng Huiliang; Chen Xueguang

    2005-01-01

    Objective: An evaluation of the reconstructed imaging of coronary arteries with 16-slice spiral CT in diagnosis of coronary disease. Methods: The reconstructed images of coronary arteries obtained on a 16-slice spiral CT scanner were reviewed in 60 cases, on which the following techniques were applied: retrospective ECG-gating, Segment method with 75% R-R interval, volume rendering technique (VRT), maximum intensity projection (MIP), mulfiplanar reconstruction (MPR), curved planar reconstruction (CPR) and CT virtual endoscopy (CTVE). Results: In all 60 cases, different stages of CHD were revealed in 21 cases; none abnormality was found in 33; and images were in poor quality in 2 cases, which was available for diagnosis. There were 4 stents planted in 4 cases: soft plaque suspected in lcase, patent in 2 and occlude in 1. Conclusion: The reconstructed imaging of coronary arteries with 16-slice spiral CT is superior modality in evaluation of severe coronary stenosis, plaques, and the pantency of the intra-luminal stents, which is an efficient and non-invasive imaging in diagnosis of early-stage CHD and screening in high risk population. (authors)

  3. The spiral

    DEFF Research Database (Denmark)

    Bibace, Roger; Kharlamov, Nikita

    2013-01-01

    ’s work with Bernard Kaplan on symbol formation is a primer on this idea. This paper examines the idea of spirality and develops the notion of dynamic coexistence that can clarify the issue of directionality of development; that is, what is the general trajectory or ground plan that development assumes...... and the environment. The idea of dynamic coexistence is developed on this foundation. In the context of Werner and Kaplan’s work, dynamic coexistence represents the syncretic nature of processes and levels of organization: they are neither innately fused nor organized. Instead, the antithesis between fusion...

  4. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  5. Spiral tectonics

    Science.gov (United States)

    Hassan Asadiyan, Mohammad

    2014-05-01

    Spiral Tectonics (ST) is a new window to global tectonics introduced as alternative model for Plate Tectonics (PT). ST based upon Dahw(rolling) and Tahw(spreading) dynamics. Analogues to electric and magnetic components in the electromagnetic theory we could consider Dahw and Tahw as components of geodynamics, when one component increases the other decreases and vice versa. They are changed to each other during geological history. D-component represents continental crust and T-component represents oceanic crust. D and T are two arm of spiral-cell. T-arm 180 degree lags behind D-arm so named Retard-arm with respect to D or Forward-arm. It seems primary cell injected several billions years ago from Earth's center therefore the Earth's core was built up first then mantel and finally the crust was build up. Crust building initiate from Arabia (Mecca). As the universe extended gravitation wave swirled the earth fractaly along cycloid path from big to small scale. In global scale (order-0) ST collect continents in one side and abandoned Pacific Ocean in the other side. Recent researches also show two mantels upwelling in opposite side of the Earth: one under Africa (tectonic pose) and the other under Pacific Ocean (tectonic tail). In higher order (order-1) ST build up Africa in one side and S.America in the other side therefore left Atlantic Ocean meandered in between. In order-n e.g. Khoor Musa and Bandar-Deylam bay are seen meandered easterly in the Iranian part but Khoor Abdullah and Kuwait bay meandered westerly in the Arabian part, they are distributed symmetrically with respect to axis of Persian Gulf(PG), these two are fractal components of easterly Caspian-wing and westerly Black Sea-wing which split up from Anatoly. Caspian Sea and Black Sea make two legs of Y-like structure, this shape completely fitted with GPS-velocity map which start from PG and split up in the Catastrophic Point(Anatoly). We could consider PG as remnants of Ancient Ocean which spent up

  6. Multislice CT imaging of pulmonary embolism

    International Nuclear Information System (INIS)

    Schoepf, J.U.; Kessler, M.A.; Rieger, C.T.; Herzog, P.; Wiesgigl, S.; Becker, C.R.; Exarhos, D.N.; Reiser, M.F.

    2001-01-01

    In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses. (orig.)

  7. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  8. Observations of barred spirals

    International Nuclear Information System (INIS)

    Elmegreen, D.M.

    1990-01-01

    Observations of barred spiral galaxies are discussed which show that the presence of a bar increases the likelihood for grand design spiral structure only in early Hubble types. This result is contrary to the more common notion that grand design spiral structure generally accompanies bars in galaxies. Enhanced deprojected color images are shown which reveal that a secondary set of spiral arms commonly occurs in barred galaxies and also occasionally in ovally distorted galaxies. 6 refs

  9. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  10. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  11. Electromechanics of graphene spirals

    Energy Technology Data Exchange (ETDEWEB)

    Korhonen, Topi; Koskinen, Pekka, E-mail: pekka.koskinen@iki.fi [NanoScience Center, Department of Physics, University of Jyväskylä, 40014 Jyväskylä (Finland)

    2014-12-15

    Among the most fascinating nanostructure morphologies are spirals, hybrids of somewhat obscure topology and dimensionality with technologically attractive properties. Here, we investigate mechanical and electromechanical properties of graphene spirals upon elongation by using density-functional tight-binding, continuum elasticity theory, and classical force field molecular dynamics. It turns out that electronic properties are governed by interlayer interactions as opposed to strain effects. The structural behavior is governed by van der Waals interaction: in its absence spirals unfold with equidistant layer spacings, ripple formation at spiral perimeter, and steadily increasing axial force; in its presence, on the contrary, spirals unfold via smooth local peeling, complex geometries, and nearly constant axial force. These electromechanical trends ought to provide useful guidelines not only for additional theoretical investigations but also for forthcoming experiments on graphene spirals.

  12. Multislice ct in gut related pathologies

    International Nuclear Information System (INIS)

    Nadeem, A.; Shaukat, A.; Ahmad, M.W.; Amin, Y.

    2007-01-01

    The objective of this study is to evaluate the effectiveness of Multislice CT in Gut related pathologies. 50 consecutive patients, referred from surgical and medical departments, with gut pathology suspicion were scanned in this respect on Toshiba MSCT 4 slice Aquilion. Patients were. 100 ml iodinated non ionic IV contrast was given. Preferably water was used as oral contrast and oral iodinated contrast was used only in selective cases. As a result, 33 patients showed positive response and 17 were normal; 23 were females and 10 were males. We found following pathologies Acute Appendicitis 10, Diverticulitis 02, Inflammatory Bowel Disease 03, Small Bowel Obstruction 04, Malignant Gut masses 08, Omental Implants 05, Perforation (Duodenal) 01. It is thus concluded that MDCT has a definite role in gut pathologies especially when the ultrasound is negative. (author)

  13. Triangular spiral tilings

    International Nuclear Information System (INIS)

    Sushida, Takamichi; Hizume, Akio; Yamagishi, Yoshikazu

    2012-01-01

    The topology of spiral tilings is intimately related to phyllotaxis theory and continued fractions. A quadrilateral spiral tiling is determined by a suitable chosen triple (ζ, m, n), where ζ element of D/R, and m and n are relatively prime integers. We give a simple characterization when (ζ, m, n) produce a triangular spiral tiling. When m and n are fixed, the admissible generators ζ form a curve in the unit disk. The family of triangular spiral tilings with opposed parastichy pairs (m, n) is parameterized by the divergence angle arg (ζ), while triangular spiral tilings with non-opposed parastichy pairs are parameterized by the plastochrone ratio 1/|ζ|. The generators for triangular spiral tilings with opposed parastichy pairs are not dense in the complex parameter space, while those with non-opposed parastichy pairs are dense. The proofs will be given in a general setting of spiral multiple tilings. We present paper-folding (origami) sheets that build spiral towers whose top-down views are triangular tilings. (paper)

  14. Application of triple rule-out with 64-slice spiral CT in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Li Pengyu; Li Kuncheng; Du Xiangyin; Cao Lizhen; Liu Jiabin; Yang Yanhuui; Liang Zhigang; Zhu Xiaolian; Liu Jian

    2007-01-01

    Objective: To investigate the performance of triple rule-out with 64-slice spiral CT in the combined examination of pulmonary artery, thoracic aorta and coronary artery for patients with acute chest pain. Methods: Seventy patients who presented with acute chest pain were included in the study. All of the patients underwent retrospective ECG-gated 64-slice computed tomography triple rule-out examination to evaluate the pulmonary arteries, thoracic aorta and coronary arteries. Multi-planar reconstruction (MPR), maximum intensity projection (MIP), curved-planar reconstruction (CPR) and volume rendering (VR) were used to display pulmonary arteries, thoracic aorta and coronary arteries. We evaluated the image quality of coronary artery and the enhancement of the pulmonary artery and thoracic aorta to estimate if the examination can fulfill the clinical demand for the differential diagnosis of acute chest pain. Results: The mean scan time was (8.5±1.0) s, and the dose of contrast medium injected was 100 ml. There were 95.7% (67/70) of patients whose CT values detected in the pulmonary artery and thoracic aorta after enhancement Were ≥200 HU. The image quality of 85.8% (720/839) coronary segments was classified as excellent, 8.6% (72/839) as good, and 5.6% (47/839) as poor. There were 20 eases with coronary stenoses ≥50%, 2 cases with pulmonary embolism, and 2 cases with aortic dissection. Conclusion: The triple rule-out examination with 64-slice spiral CT could depict pulmonary artery, thoracic aorta, and coronary artery in 8 s with good image quality. It has great potential in the etiological diagnosis for the patients with acute chest pain. (authors)

  15. Spiral Countercurrent Chromatography

    Science.gov (United States)

    Ito, Yoichiro; Knight, Martha; Finn, Thomas M.

    2013-01-01

    For many years, high-speed countercurrent chromatography conducted in open tubing coils has been widely used for the separation of natural and synthetic compounds. In this method, the retention of the stationary phase is solely provided by the Archimedean screw effect by rotating the coiled column in the centrifugal force field. However, the system fails to retain enough of the stationary phase for polar solvent systems such as the aqueous–aqueous polymer phase systems. To address this problem, the geometry of the coiled channel was modified to a spiral configuration so that the system could utilize the radially acting centrifugal force. This successfully improved the retention of the stationary phase. Two different types of spiral columns were fabricated: the spiral disk assembly, made by stacking multiple plastic disks with single or four interwoven spiral channels connected in series, and the spiral tube assembly, made by inserting the tetrafluoroethylene tubing into a spiral frame (spiral tube support). The capabilities of these column assemblies were successfully demonstrated by separations of peptides and proteins with polar two-phase solvent systems whose stationary phases had not been well retained in the earlier multilayer coil separation column for high-speed countercurrent chromatography. PMID:23833207

  16. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  17. Spirals on the sea

    Directory of Open Access Journals (Sweden)

    Walter Munk

    2001-12-01

    Full Text Available Spiral eddies were first seen in the sun glitter on the Apollo Mission 30 years ago; they have since been recorded on SAR missions and in the infrared. The spirals are globally distributed, 10-25 km in size and overwhelmingly cyclonic. They have not been explained. Under light winds favorable to visualization, linear surface features with high surfactant density and low surface roughness are of common occurrence. We have proposed that frontal formations concentrate the ambient shear and prevailing surfactants. Horizontal shear instabilities ensue when the shear becomes comparable to the coriolis frequency. The resulting vortices wind the liner features into spirals. The hypothesis needs to be tested by prolonged measurements and surface truth. Spiral eddies are a manifestation of a sub-mesoscale oceanography associated with upper ocean stirring; dimensional considerations suggest a horizontal diffusivity of order 103 m2 s-1.

  18. Analysis of hepatic vein variations in healthy people with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Zhang Rong; Li Yong; Shen Jun; Zeng Weike; Li Jieting; Huang Suiqiao; Liang Biling; Liu Chao

    2007-01-01

    Objective: To analyze variations of hepatic vein in healthy people with 64-slice spiral CT. Methods: Seventy-five healthy subjects underwent multi-slice spiral computed (MSCT) hepatic venography. The anatomy of the junction of the hepatic veins with the inferior vena cava and the intrahepatic drainage territory of the hepatic veins and tributaries were evaluated. The hepatic veins were classified according to three anatomic classification (Nakamura's, Marcos's and Kawasaki's classification) methods respectively. Results: There was a common trunk of the middle and left hepatic veins before joining the IVC in 86.7% (65/75)of the cases. In 13.3% (10/75)of the cases, the three main hepatic veins joined the IVC separately. The ratios of Nakamma's classification type A, B, C of hepatic veins were 49.4% (37/75), 37.3% (28/75), and 13.3% (10/75) respectively. The ratios of Marcos's classification type A, B, C of hepatic veins were 56.0% (42/75), 24.0% (18/75), and 20.0% (15/75) respectively. The ratios of Kawasaki's classification type I, II of hepatic vein were 40.0% (30/75) and 60.0% (45/75). Conclusion: Multi-slice spiral CT hepatic venography can provide visualization of peripheral hepatic venous branches in details. (authors)

  19. Spiral 2 Week

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The main goal of this meeting is to present and discuss the current status of the Spiral-2 project at GANIL in front of a large community of scientists and engineers. Different issues have been tackled particularly the equipment around Spiral-2 like injectors, cryo-modules or beam diagnostics, a workshop was devoted to other facilities dedicated to radioactive ion beam production. This document gathers only the slides of the presentations.

  20. Stacking the Equiangular Spiral

    OpenAIRE

    Agrawal, A.; Azabi, Y. O.; Rahman, B. M.

    2013-01-01

    We present an algorithm that adapts the mature Stack and Draw (SaD) methodology for fabricating the exotic Equiangular Spiral Photonic Crystal Fiber. (ES-PCF) The principle of Steiner chains and circle packing is exploited to obtain a non-hexagonal design using a stacking procedure based on Hexagonal Close Packing. The optical properties of the proposed structure are promising for SuperContinuum Generation. This approach could make accessible not only the equiangular spiral but also other qua...

  1. Spiral 2 Week

    International Nuclear Information System (INIS)

    2007-01-01

    The main goal of this meeting is to present and discuss the current status of the Spiral-2 project at GANIL in front of a large community of scientists and engineers. Different issues have been tackled particularly the equipment around Spiral-2 like injectors, cryo-modules or beam diagnostics, a workshop was devoted to other facilities dedicated to radioactive ion beam production. This document gathers only the slides of the presentations

  2. High-Assurance Spiral

    Science.gov (United States)

    2017-11-01

    HIGH-ASSURANCE SPIRAL CARNEGIE MELLON UNIVERSITY NOVEMBER 2017 FINAL TECHNICAL REPORT APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED STINFO...MU 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Carnegie Mellon University 5000 Forbes Ave Pittsburgh, PA 15217 8. PERFORMING ORGANIZATION...Approved for Public Release; Distribution Unlimited. Carnegie Mellon Carnegie Mellon HA SPIRAL Code Synthesis KeYmaera X Hybrid Theorem Prover

  3. Multislice CT imaging of anomalous coronary arteries

    International Nuclear Information System (INIS)

    Shi Heshui; Aschoff, Andrik J.; Brambs, Hans-Juergen; Hoffmann, Martin H.K.

    2004-01-01

    The purpose of the present study was to evaluate the role of 16 multislice computed tomography (MSCT) to identify the origin of anomalous coronary arteries and to confirm their anatomic course in relation to the great vessels. Accuracy of coronary artery disease (CAD) detection was a secondary aim and was tested with conventional angiograms (CA) serving as standard of reference. Two hundred and forty-two consecutive patients referred for noninvasive coronary CT imaging were reviewed for the study. Sixteen patients (6.6%) with anomalous coronary arteries were detected and included as the study group. MSCT and CA images were analyzed in a blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Accuracy ratios to detect CAD with MSCT in all vessels were calculated. Coronary anomalies for all 16 patients were correctly displayed on MSCT. CA alone achieved correct identification of the abnormality in only 53% (P=0.016). Sensitivity and specificity of MSCT to detect significantly stenosed vessels was 90 and 92%. 16-MSCT is accurate to delineate abnormally branching coronary arteries and allows sufficiently accurate detection of obstructive coronary artery disease in distal branches. It should therefore be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (orig.)

  4. High assurance SPIRAL

    Science.gov (United States)

    Franchetti, Franz; Sandryhaila, Aliaksei; Johnson, Jeremy R.

    2014-06-01

    In this paper we introduce High Assurance SPIRAL to solve the last mile problem for the synthesis of high assurance implementations of controllers for vehicular systems that are executed in today's and future embedded and high performance embedded system processors. High Assurance SPIRAL is a scalable methodology to translate a high level specification of a high assurance controller into a highly resource-efficient, platform-adapted, verified control software implementation for a given platform in a language like C or C++. High Assurance SPIRAL proves that the implementation is equivalent to the specification written in the control engineer's domain language. Our approach scales to problems involving floating-point calculations and provides highly optimized synthesized code. It is possible to estimate the available headroom to enable assurance/performance trade-offs under real-time constraints, and enables the synthesis of multiple implementation variants to make attacks harder. At the core of High Assurance SPIRAL is the Hybrid Control Operator Language (HCOL) that leverages advanced mathematical constructs expressing the controller specification to provide high quality translation capabilities. Combined with a verified/certified compiler, High Assurance SPIRAL provides a comprehensive complete solution to the efficient synthesis of verifiable high assurance controllers. We demonstrate High Assurance SPIRALs capability by co-synthesizing proofs and implementations for attack detection and sensor spoofing algorithms and deploy the code as ROS nodes on the Landshark unmanned ground vehicle and on a Synthetic Car in a real-time simulator.

  5. Spiral silicon drift detectors

    International Nuclear Information System (INIS)

    Rehak, P.; Gatti, E.; Longoni, A.; Sampietro, M.; Holl, P.; Lutz, G.; Kemmer, J.; Prechtel, U.; Ziemann, T.

    1988-01-01

    An advanced large area silicon photodiode (and x-ray detector), called Spiral Drift Detector, was designed, produced and tested. The Spiral Detector belongs to the family of silicon drift detectors and is an improvement of the well known Cylindrical Drift Detector. In both detectors, signal electrons created in silicon by fast charged particles or photons are drifting toward a practically point-like collection anode. The capacitance of the anode is therefore kept at the minimum (0.1pF). The concentric rings of the cylindrical detector are replaced by a continuous spiral in the new detector. The spiral geometry detector design leads to a decrease of the detector leakage current. In the spiral detector all electrons generated at the silicon-silicon oxide interface are collected on a guard sink rather than contributing to the detector leakage current. The decrease of the leakage current reduces the parallel noise of the detector. This decrease of the leakage current and the very small capacities of the detector anode with a capacitively matched preamplifier may improve the energy resolution of Spiral Drift Detectors operating at room temperature down to about 50 electrons rms. This resolution is in the range attainable at present only by cooled semiconductor detectors. 5 refs., 10 figs

  6. Visualization of normal and abnormal inner ear with volume rendering technique using multislice spiral CT

    International Nuclear Information System (INIS)

    Ma Hui; Han Ping; Liang Bo; Lei Ziqiao; Liu Fang; Tian Zhiliang

    2006-01-01

    Objective: To evaluate the ability of the volume rendering technique to display the normal and abnormal inner ear structures. Methods: Forty normal earand 61 abnormal inner ears (40 congenital inner ear malformations, 7 labyrinthitis ossificans, and 14 inner ear erosion caused by cholesteatomas) were examined with a MSCT scanner. Axial imaging were performed using the following parameters: 120 kV, 100 mAs, 0.75 mm slice thickness, a pitch factor of 1. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment and a FOV of 50 mm. The 3D reconstructions were done with volume rendering technique on the workstation. Results: In the subjects without ear disorders a high quality 3D visualization of the inner ear could be achieved. In the patients with inner ear' disorders all inner ear malformations could be clearly displayed on 3D images as follows: (1) Michel deformity (one ear): There was complete absence of all cochlear and vestibular structures. (2) common cavity deformity (3 ears): The cochlea and vestibule were represented by a cystic cavity and couldn't be differentiated from each other. (3)incomplete partition type I (3 ears): The cochlea lacked the entire modiolus and cribriform area, resulting in a cystic appearance. (4) incomplete partition type II (Mondini deformity) (5 ears): The cochlea consisted of 1.5 turns, in which the middle and apical turns coalesced to form a cystic apex. (5) vestibular and semicircular canal malformations (14 ears): Cochlea was normal, vestibule dilated, semicircular canals were absent, hypoplastic or enlarged. (6) dilated vestibular aqueduct (14 ears): The vestibular aqueduct was bell-mouthed. In 7 patients with labyrinthifis ossificans, 3D images failed to clearly show the completeinner ears in 4 ears because of too high ossifications in the membranous labyrinth. In the other 3 ears volume rendering could display the thin cochlea basal turn and the intermittent semicircular canals. In the patients with cholesteatomas 3 D volume rendering images could identify the site of the bony labyrinth erosion and its surrounding structures. Conclusions: Volume rendering technique can provide higher quality three-dimensional images of the bony labyrinth and serves as a useful tool for analysis of normal and anomalies of the inner ear. (authors)

  7. Quantitative assessment of pulmonary function using low dose multi-slice spiral CT in smoker

    International Nuclear Information System (INIS)

    Chen Huai; Zeng Qingsi; Zheng Jinping; Guan Yubao; Zhang Chaoliang; Cen Renli

    2012-01-01

    Objective: To evaluate the clinical feasibility of low dose MSCT for quantitative assessment of pulmonary function in smokers. Methods: One hundred and forty-six patients with chronic objective pulmonary disease (COPD) including 109 smokers (74.6%) and 37 non-smokers (25.3%) underwent pulmonary function test and low-dose MSCT scan. All data were analyzed using computer-aided lung analysis software. Pulmonary function parameters from low-dose MSCT were compared between smokers and non-smokers and also compared with pulmonary function test in non-smokers (Pearson test). Results: In smokers, the average volume at full inspiratory phase (Vin) was (5125 ± 862 ) ml, mean lung attenuation was (-902 ± 26) HU, mean lung density was (0.0984 ± 0.0260 ) g/cm 3 , emphysema volume was (2890 ±1370) ml. The average volume at full expiratory phase (Vex) was (2756 ±1027) ml, mean lung attenuation was (-811 ±62) HU, mean lung density was (0.1878 ±0.0631) g/cm 3 , emphysema volume was (685 ±104) ml. In non-smokers, the average Vin was (3734 ± 759) ml, mean lung attenuation was (-876 ±40) HU,mean lung density was (0.1244 ±0.0401)g/cm 3 , emphysema volume was ( 1503 ± 1217) ml. The average Vex was (1770 ± 679) ml, mean lung attenuation was (-765 ± 56) HU, mean lung density was (0.2360 ± 0.0563) g/cm 3 , emphysema volume was (156 ± 45) ml. There were significant differences between smokers and non-smokers (P<0.01). The Vex/Vin was correlated with residual volume/total lung capacity (RV/TLC, r=0.60, P<0.01), and Vin was correlated with TLC (r=0.58, P<0.01), Vex with RV (r=0.59, P<0.01). Pixel index (PI) -950 in was correlated with FEV 1% pre and FEV1/FVC% (r=-0.53, -0.62, respective, P<0.01), Pl-950ex was correlated with FEV1 % pre and FEV1/FVC% (r=-0.71, -0.77, respective, P<0.01). Conclusion: Low-dose MSCT can be a potential imaging tool for quantitative pulmonary function assessment in smokes. (authors)

  8. Imaging of Pericardiophrenic Bundles Using Multislice Spiral Computed Tomography for Phrenic Nerve Anatomy.

    Science.gov (United States)

    Wang, Yan-Jing; Liu, Lin; Zhang, Meng-Chao; Sun, Huan; Zeng, Hong; Yang, Ping

    2016-08-01

    Phrenic nerve injury and diaphragmatic stimulation are common complications following arrhythmia ablation and pacing therapies. Preoperative comprehension of phrenic nerve anatomy via non-invasive CT imaging may help to minimize the electrophysiological procedure-related complications. Coronary CT angiography data of 121 consecutive patients were collected. Imaging of left and right pericardiophrenic bundles was performed with volume rendering and multi-planar reformation techniques. The shortest spatial distances between phrenic nerves and key electrophysiology-related structures were determined. The frequencies of the shortest distances ≤5 mm, >5 mm and direct contact between phrenic nerves and adjacent structures were calculated. Left and right pericardiophrenic bundles were identified in 86.8% and 51.2% of the patients, respectively. The right phrenic nerve was phrenic nerve, phrenic nerve was phrenic nerve had a distance phrenic nerve showed a distance phrenic nerve anatomy, which might facilitate avoidance of the phrenic nerve-related complications in interventional electrophysiology. © 2016 Wiley Periodicals, Inc.

  9. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    International Nuclear Information System (INIS)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N.

    2006-01-01

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results

  10. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N. [Medical Univ. of Bologna, S. Orsola-Malpighi Policlinic (Italy). Dept. of Radiology

    2006-10-15

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results.

  11. Plasma Generator Using Spiral Conductors

    Science.gov (United States)

    Szatkowski, George N. (Inventor); Dudley, Kenneth L. (Inventor); Ticatch, Larry A. (Inventor); Smith, Laura J. (Inventor); Koppen, Sandra V. (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor)

    2016-01-01

    A plasma generator includes a pair of identical spiraled electrical conductors separated by dielectric material. Both spiraled conductors have inductance and capacitance wherein, in the presence of a time-varying electromagnetic field, the spiraled conductors resonate to generate a harmonic electromagnetic field response. The spiraled conductors lie in parallel planes and partially overlap one another in a direction perpendicular to the parallel planes. The geometric centers of the spiraled conductors define endpoints of a line that is non-perpendicular with respect to the parallel planes. A voltage source coupled across the spiraled conductors applies a voltage sufficient to generate a plasma in at least a portion of the dielectric material.

  12. Barred spiral structure of galaxies

    International Nuclear Information System (INIS)

    Chen, Z.; Weng, s.; Xu, M.

    1982-01-01

    Observational data indicate the grand design of spiral or barred spiral structure in disk galaxies. The problem of spiral structure has been thoroughly investigated by C. C. Lin and his collaborators, but yet the problem of barred spiral structure has not been investigated systematically, although much work has been done, such as in Ref. 3--7. Using the gasdynamic model for galaxies and a method of integral transform presented in Ref. 1, we investigated the barred spiral structure and obtained an analytical solution. It gives the large-scale pattern of barred-spirals, which is in fairly good agreement with observational data

  13. Mapping the extent of disease by multislice computed tomography, magnetic resonance imaging and sentinel node evaluation in stage I and II cervical carcinoma

    Directory of Open Access Journals (Sweden)

    Rajaram S

    2010-01-01

    Full Text Available Aims: (1 To map the extent of disease in women with stage I and II carcinoma cervix by multislice spiral computed tomography (CT, magnetic resonance imaging (MRI and sentinel nodes. (2 To assess accuracy of each modality individually and in conjunction with FIGO clinical staging. Design and Setting: Prospective, single-blind study. Departments of Obstetrics and Gynaecology, Radiodiagnosis, and Pathology, UCMS and GTBH and Division of Radiological Imaging and Bioinformatics, INMAS, Delhi. Material and Method: The study was conducted on 25 women with cervical cancer FIGO stage I and II. Each woman underwent clinical staging, multislice spiral CT and MRI which was compared to the gold-standard histopathology/cytology. The overall accuracy of each modality and improvement of clinical staging by CT/MRI were noted. Sentinel nodes were evaluated by intracervical Patent Blue V dye injection. Statistical Analysis: Sensitivity, specificity, positive and negative predictive values were calculated by 2Χ2 contingency tables. Results: The accuracy of staging by FIGO, CT and MRI was 68%, 52% and 80%, respectively. MRI and CT improved the overall accuracy of FIGO staging to 96% and 80%, respectively. Sentinel nodes were identified in 89% of patients with 91% accuracy. Conclusion: MRI emerges as the most valuable stand-alone modality improving accuracy of FIGO staging to 96%. Sentinel lymph-node evaluation appears promising in evaluating spread beyond cervix.

  14. Chiral Magnetic Spirals

    International Nuclear Information System (INIS)

    Basar, Goekce; Dunne, Gerald V.; Kharzeev, Dmitri E.

    2010-01-01

    We argue that the presence of a very strong magnetic field in the chirally broken phase induces inhomogeneous expectation values, of a spiral nature along the magnetic field axis, for the currents of charge and chirality, when there is finite baryon density or an imbalance between left and right chiralities. This 'chiral magnetic spiral' is a gapless excitation transporting the currents of (i) charge (at finite chirality), and (ii) chirality (at finite baryon density) along the direction of the magnetic field. In both cases it also induces in the transverse directions oscillating currents of charge and chirality. In heavy ion collisions, the chiral magnetic spiral possibly provides contributions both to the out-of-plane and the in-plane dynamical charge fluctuations recently observed at BNL RHIC.

  15. The Spiral of Euroscepticism

    DEFF Research Database (Denmark)

    Galpin, Charlotte; Trenz, Hans-Jörg

    2017-01-01

    of Euroscepticism’, taking media autonomy seriously to understand how media logics and selective devices contribute to the shaping of public discourse about the EU. We review the literature on the media and EU legitimacy to show how media frames and their amplification on social media can account for the salience......Media scholars have increasingly examined the effects of a negativity bias that applies to political news. In the ‘spiral of cynicism’, journalist preferences for negative news correspond to public demands for sensational news. We argue that this spiral of cynicism in EU news results in a ‘spiral...... of Eurosceptic opinions in the public sphere that then push parties to contest the EU in predominantly negative terms....

  16. Embracing the Spiral

    Directory of Open Access Journals (Sweden)

    Li Mao

    2016-12-01

    Full Text Available Critical research demands that we interrogate our own positionality and social location. Critical reflexivity is a form of researcher critical consciousness that is constant and dynamic in a complex spiral-like process starting within our own experiences as racialized, gendered, and classed beings embedded in particular sociopolitical contexts. Across diverse critical methodologies, a group of graduate students and their supervisor explored their own conceptualization of the reflexivity spiral by reflecting on how their research motivations and methodologies emerged from their racializing, colonizing, language-learning, parenting, and identity negotiating experiences. In this article, they present a spiral model of the critical reflexivity process, review the literature on reflexivity, and conclude with a description of critical reflexivity as a social practice within a supportive and collaborative graduate school experience.

  17. The spinning ball spiral

    International Nuclear Information System (INIS)

    Dupeux, Guillaume; Le Goff, Anne; Quere, David; Clanet, Christophe

    2010-01-01

    We discuss the trajectory of a fast revolving solid ball moving in a fluid of comparable density. As the ball slows down owing to drag, its trajectory follows an exponential spiral as long as the rotation speed remains constant: at the characteristic distance L where the ball speed is significantly affected by the drag, the bending of the trajectory increases, surprisingly. Later, the rotation speed decreases, which makes the ball follow a second kind of spiral, also described in the paper. Finally, the use of these highly curved trajectories is shown to be relevant to sports.

  18. Assessment of multislice CT to quantify pulmonary emphysema function and physiology in a rat model

    Science.gov (United States)

    Cao, Minsong; Stantz, Keith M.; Liang, Yun; Krishnamurthi, Ganapathy; Presson, Robert G., Jr.

    2005-04-01

    Purpose: The purpose of this study is to evaluate multi-slice computed tomography technology to quantify functional and physiologic changes in rats with pulmonary emphysema. Method: Seven rats were scanned using a 16-slice CT (Philips MX8000 IDT) before and after artificial inducement of emphysema. Functional parameters i.e. lung volumes were measured by non-contrast spiral scan during forced breath-hold at inspiration and expiration followed by image segmentation based on attenuation threshold. Dynamic CT imaging was performed immediately following the contrast injection to estimate physiology changes. Pulmonary perfusion, fractional blood volume, and mean transit times (MTTs) were estimated by fitting the time-density curves of contrast material using a compartmental model. Results: The preliminary results indicated that the lung volumes of emphysema rats increased by 3.52+/-1.70mL (pemphysema rats decreased by 91.76+/-68.11HU (pemphysema rats were 0.25+/-0.04ml/s/ml and 0.32+/-0.09ml/s/ml respectively. The fractional blood volumes for normal and emphysema rats were 0.21+/-0.04 and 0.15+/-0.02. There was a trend toward faster MTTs for emphysema rats (0.42+/-0.08s) than normal rats (0.89+/-0.19s) with ppulmonary emphysema appears promising for small animals.

  19. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    Science.gov (United States)

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  20. The diagnostic value of multi-slice CT on the congenital malformation of coronary sinus

    International Nuclear Information System (INIS)

    Li Wei; Ma Xiaojing; Sun Qingjun

    2012-01-01

    Objective: To investigate the application value of multi-slice spiral CT on the congenital malformation of coronary sinus. Methods: MSCT finding of 98 patients with coronary sinus malformation confirmed by surgery were retrospectively analyzed,and the cases were divided into four categories based on the Mantini theory and comparison was made between the diagnosis from ultrasound and CT. A 2 × 2 table for Chi-square test was also used for statistics analysis. Results: Among 98 patients,there were 72 patients with persistent left superior vena cava reflowed to right atria through coronary sinus, with 48 patients diagnosed by ultrasound and 72 patients by MSCT; there were 13 patients with anomalous pulmonary venous connection to coronary sinus, with 12 patients diagnosed by ultrasound and 13 patients by MSCT diagnosis; there were 10 patients with unroofed coronary sinus syndrome, with 6 patients diagnosed by ultrasound and 8 patients by MSCT, there were 2 patients with coronary sinus atresia, all diagnosed by MSCT; there were 1 patient with coronary sinus anomaly reflow to left arita. The significant difference between 2 modalities (χ 2 =22.7, P<0.01) shows that CT is superior to ultrasound. Conclusion: MSCT is much more better than ultrasound in the diagnosis of malformation of coronary sinus and it can provide reliable diagnosis prior to surgery or interventional therapy. (authors)

  1. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas H.; Katoh, Markus; Guenther, Rolf W.; Wildberger, Joachim E.; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Gietema, H.A.; Prokop, Mathias; Czech, Andre; Diederich, Stefan; Bakai, Annemarie; Salganicoff, Marcos

    2007-01-01

    The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm 3 -525 mm 3 ), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (±7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (±11.1%) for the GE scanner, 9.7% (±9.6%) for the Philips scanner and 7.5% (±7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm 3 . Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies. (orig.)

  2. Are spiral galaxies heavy smokers?

    International Nuclear Information System (INIS)

    Davies, J.; Disney, M.; Phillipps, S

    1990-01-01

    The dustiness of spiral galaxies is discussed. Starburst galaxies and the shortage of truly bright spiral galaxies is cited as evidence that spiral galaxies are far dustier than has been thought. The possibility is considered that the dust may be hiding missing mass

  3. Properties of spiral resonators

    International Nuclear Information System (INIS)

    Haeuser, J.

    1989-10-01

    The present thesis deals with the calculation and the study of the application possibilities of single and double spiral resonators. The main aim was the development and the construction of reliable and effective high-power spiral resonators for the UNILAC of the GSI in Darmstadt and the H - -injector for the storage ring HERA of DESY in Hamburg. After the presentation of the construction and the properties of spiral resonators and their description by oscillating-circuit models the theoretical foundations of the bunching are presented and some examples of a rebuncher and debuncher and their influence on the longitudinal particle dynamics are shown. After the description of the characteristic accelerator quantities by means of an oscillating-circuit model and the theory of an inhomogeneous λ/4 line it is shown, how the resonance frequency and the efficiency of single and double spiral resonators can be calculated from the geometrical quantities of the structure. In the following the dependence of the maximal reachable resonator voltage in dependence on the gap width and the surface of the drift tubes is studied. Furthermore the high-power resonators are presented, which were built for the different applications for the GSI in Darmstadt, DESY in Hamburg, and for the FOM Institute in Amsterdam. (orig./HSI) [de

  4. Tracking Target and Spiral Waves

    DEFF Research Database (Denmark)

    Jensen, Flemming G.; Sporring, Jon; Nielsen, Mads

    2002-01-01

    A new algorithm for analyzing the evolution of patterns of spiral and target waves in large aspect ratio chemical systems is introduced. The algorithm does not depend on finding the spiral tip but locates the center of the pattern by a new concept, called the spiral focus, which is defined...... by the evolutes of the actual spiral or target wave. With the use of Gaussian smoothing, a robust method is developed that permits the identification of targets and spirals foci independently of the wave profile. Examples of an analysis of long image sequences from experiments with the Belousov......–Zhabotinsky reaction catalyzed by ruthenium-tris-bipyridyl are presented. Moving target and spiral foci are found, and the speed and direction of movement of single as well as double spiral foci are investigated. For the experiments analyzed in this paper it is found that the movement of a focus correlates with foci...

  5. Forming Spirals From Shadows

    Science.gov (United States)

    Kohler, Susanna

    2016-07-01

    What causes the large-scale spiral structures found in some protoplanetary disks? Most models assume theyre created by newly-forming planets, but a new study suggests that planets might have nothing to do with it.Perturbations from Planets?In some transition disks protoplanetary disks with gaps in their inner regions weve directly imaged large-scale spiral arms. Many theories currently attribute the formation of these structures to young planets: either the direct perturbations of a planet embedded in the disk cause the spirals, or theyre indirectly caused by the orbit of a planetary body outside of the arms.Another example of spiral arms detected in a protoplanetary disk, MWC 758. [NASA/ESA/ESO/M. Benisty et al.]But what if you could get spirals without any planets? A team of scientists led by Matas Montesinos (University of Chile) have recently published a study in which they examine what happens to a shadowed protoplanetary disk.Casting Shadows with WarpsIn the teams setup, they envision a protoplanetary disk that is warped: the inner region is slightly tilted relative to the outer region. As the central star casts light out over its protoplanetary disk, this disk warping would cause some regions of the disk to be shaded in a way that isnt axially symmetric with potentially interesting implications.Montesinos and collaborators ran 2D hydrodynamics simulations to determine what happens to the motion of particles within the disk when they pass in and out of the shadowed regions. Since the shadowed regions are significantly colder than the illuminated disk, the pressure in these regions is much lower. Particles are therefore accelerated and decelerated as they pass through these regions, and the lack of axial symmetry causes spiral density waves to form in the disk as a result.Initial profile for the stellar heating rate per unit area for one of the authors simulations. The regions shadowed as a result of the disk warp subtend 0.5 radians each (shown on the left

  6. Theory of spiral structure

    International Nuclear Information System (INIS)

    Lin, C.C.

    1977-01-01

    The density wave theory of galactic spirals has now developed into a form suitable for consideration by experts in Applied Mechanics. On the one hand, comparison of theoretical deductions with observational data has convinced astrophysicists of the validity of the basic physical picture and the calculated results. On the other hand, the dynamical problems of a stellar system, such as those concerning the origin of spiral structure in galaxies, have not been completely solved. This paper reviews the current status of such developments, including a brief summary of comparison with observations. A particularly important mechanism, currently called the mechanism of energy exchange, is described in some detail. The mathematical problems and the physical processes involved are similar to those occurring in certain instability mechanisms in the 'magnetic bottle' designed for plasma containment. Speculations are given on the future developments of the theory and on observational programs. (Auth.)

  7. Spiral 2 workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The accelerator and experimental facilities at GANIL will be transformed over the next 5-10 years. The centerpiece of the additions to the accelerator complex will be Spiral-2. This is the first phase of a new radioactive beam facility based on the ISOL principle. The main aim of Spiral-2 will be to produce intense, high quality beams of neutron-rich nuclei created in neutron-induced fission of heavy elements and accelerated by the existing CIME cyclotron. The principal aims of this workshop will be a) to publicize the new facilities, b) to discuss and define the science which might be carried out with them, c) to discuss the instrumentation and infrastructure required to exploit the new facilities and d) to help form collaborations of scientists wishing to design and construct the equipment needed to undertake the science programme. This document gathers most of the slides presented in the workshop.

  8. Spiral nonimaging optical designs

    Science.gov (United States)

    Zamora, Pablo; Benítez, Pablo; Miñano, Juan C.; Vilaplana, Juan

    2011-10-01

    Manufacturing technologies as injection molding or embossing specify their production limits for minimum radii of the vertices or draft angle for demolding, for instance. In some demanding nonimaging applications, these restrictions may limit the system optical efficiency or affect the generation of undesired artifacts on the illumination pattern. A novel manufacturing concept is presented here, in which the optical surfaces are not obtained from the usual revolution symmetry with respect to a central axis (z axis), but they are calculated as free-form surfaces describing a spiral trajectory around z axis. The main advantage of this new concept lies in the manufacturing process: a molded piece can be easily separated from its mold just by applying a combination of rotational movement around axis z and linear movement along axis z, even for negative draft angles. Some of these spiral symmetry examples will be shown here, as well as their simulated results.

  9. Spiral 2 workshop

    International Nuclear Information System (INIS)

    2004-01-01

    The accelerator and experimental facilities at GANIL will be transformed over the next 5-10 years. The centerpiece of the additions to the accelerator complex will be Spiral-2. This is the first phase of a new radioactive beam facility based on the ISOL principle. The main aim of Spiral-2 will be to produce intense, high quality beams of neutron-rich nuclei created in neutron-induced fission of heavy elements and accelerated by the existing CIME cyclotron. The principal aims of this workshop will be a) to publicize the new facilities, b) to discuss and define the science which might be carried out with them, c) to discuss the instrumentation and infrastructure required to exploit the new facilities and d) to help form collaborations of scientists wishing to design and construct the equipment needed to undertake the science programme. This document gathers most of the slides presented in the workshop

  10. Holographic Chiral Magnetic Spiral

    International Nuclear Information System (INIS)

    Kim, Keun-Young; Sahoo, Bindusar; Yee, Ho-Ung

    2010-06-01

    We study the ground state of baryonic/axial matter at zero temperature chiral-symmetry broken phase under a large magnetic field, in the framework of holographic QCD by Sakai-Sugimoto. Our study is motivated by a recent proposal of chiral magnetic spiral phase that has been argued to be favored against previously studied phase of homogeneous distribution of axial/baryonic currents in terms of meson super-currents dictated by triangle anomalies in QCD. Our results provide an existence proof of chiral magnetic spiral in strong coupling regime via holography, at least for large axial chemical potentials, whereas we don't find the phenomenon in the case of purely baryonic chemical potential. (author)

  11. Diagnostic value of 64 multislice computed tomography in the assessment of the coronary graft patency

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis R; Mendoza Rodriguez, Vladimir; Olivares Aquiles, Eddy

    2011-01-01

    Symptoms recurrence after surgical coronary artery revascularization requires the assessment of graft patency. At the moment, promissory results have been reported using the multislice computed tomography

  12. Three-dimensional multislice CT imaging of otitis media

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro; Wada, Akihiro; Ando, Ichiro

    2002-01-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  13. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  14. Band-notched spiral antenna

    Science.gov (United States)

    Jeon, Jae; Chang, John

    2018-03-13

    A band-notched spiral antenna having one or more spiral arms extending from a radially inner end to a radially outer end for transmitting or receiving electromagnetic radiation over a frequency range, and one or more resonance structures positioned adjacent one or more segments of the spiral arm associated with a notch frequency band or bands of the frequency range so as to resonate and suppress the transmission or reception of electromagnetic radiation over said notch frequency band or bands.

  15. Nature of galaxy spiral arms

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1984-01-01

    The nature of galaxy spiral arms is discussed in a popular form. Two approaches in the theory of spiral arms are considered; they are related to the problem of differential galaxy rotation and the spiral structure wave theory. The example of Galaxy M31 is considered to compare the structural peculiarity of its spiral arms with the wave theory predictions. The situation in the central and south-eastern part of arm S4 in Galaxy M31 noted to be completely explained by the wave theory and modern concepts on the origin of massive stars

  16. Measuring nutrient spiralling in streams

    Energy Technology Data Exchange (ETDEWEB)

    Newbold, J D; Elwood, J W; O' Neill, R V; Van Winkle, W

    1981-01-01

    Nutrient cycling in streams involves some downstream transport before the cycle is completed. Thus, the path traveled by a nutrient atom in passing through the cycle can be visualized as a spiral. As an index of the spiralling process, we introduce spiralling length, defined as the average distance associated with one complete cycle of a nutrient atom. This index provides a measure of the utilization of nutrients relative to the available supply from upstream. Using /sup 32/p as a tracer, we estimated a spiralling length of 193 m for phosphorus in a small woodland stream.

  17. Three phase spiral liver Scanning

    International Nuclear Information System (INIS)

    Kanyanja, T.A.

    2006-01-01

    The ability to perform rapid back-to-back spiral acquisitions is an important recent technical advantage of spiral CT. this allows imaging of the upper abdomen (liver) during peak arterial enhancement (arterial phase) and during peak hepatic parenchymal enhancement (portal venous phase). Breatheld spiral CT has completely replaced dynamic incremental CT for evaluation of the liver. in selected patients with hyper vascular metastasis (hepatoma, neuroendocrine tumors, renal cell carcinoma, etc.) a biphasic examination is performed with one spiral acquisition obtained during the hepatic arterial phase and a second acquisition during the portal venous phase

  18. The subtropical nutrient spiral

    Science.gov (United States)

    Jenkins, William J.; Doney, Scott C.

    2003-12-01

    We present an extended series of observations and more comprehensive analysis of a tracer-based measure of new production in the Sargasso Sea near Bermuda using the 3He flux gauge technique. The estimated annually averaged nitrate flux of 0.84 ± 0.26 mol m-2 yr-1 constitutes only that nitrate physically transported to the euphotic zone, not nitrogen from biological sources (e.g., nitrogen fixation or zooplankton migration). We show that the flux estimate is quantitatively consistent with other observations, including decade timescale evolution of the 3H + 3He inventory in the main thermocline and export production estimates. However, we argue that the flux cannot be supplied in the long term by local diapycnal or isopycnal processes. These considerations lead us to propose a three-dimensional pathway whereby nutrients remineralized within the main thermocline are returned to the seasonally accessible layers within the subtropical gyre. We describe this mechanism, which we call "the nutrient spiral," as a sequence of steps where (1) nutrient-rich thermocline waters are entrained into the Gulf Stream, (2) enhanced diapycnal mixing moves nutrients upward onto lighter densities, (3) detrainment and enhanced isopycnal mixing injects these waters into the seasonally accessible layer of the gyre recirculation region, and (4) the nutrients become available to biota via eddy heaving and wintertime convection. The spiral is closed when nutrients are utilized, exported, and then remineralized within the thermocline. We present evidence regarding the characteristics of the spiral and discuss some implications of its operation within the biogeochemical cycle of the subtropical ocean.

  19. Rebuilding Spiral Galaxies

    Science.gov (United States)

    2005-01-01

    Major Observing Programme Leads to New Theory of Galaxy Formation Summary Most present-day large galaxies are spirals, presenting a disc surrounding a central bulge. Famous examples are our own Milky Way or the Andromeda Galaxy. When and how did these spiral galaxies form? Why do a great majority of them present a massive central bulge? An international team of astronomers [1] presents new convincing answers to these fundamental questions. For this, they rely on an extensive dataset of observations of galaxies taken with several space- and ground-based telescopes. In particular, they used over a two-year period, several instruments on ESO's Very Large Telescope. Among others, their observations reveal that roughly half of the present-day stars were formed in the period between 8,000 million and 4,000 million years ago, mostly in episodic burst of intense star formation occurring in Luminous Infrared Galaxies. From this and other evidence, the astronomers devised an innovative scenario, dubbed the "spiral rebuilding". They claim that most present-day spiral galaxies are the results of one or several merger events. If confirmed, this new scenario could revolutionise the way astronomers think galaxies formed. PR Photo 02a/05: Luminosity - Oxygen Abundance Relation for Galaxies (VLT) PR Photo 02b/05: The Spiral Rebuilding Scenario A fleet of instruments How and when did galaxies form? How and when did stars form in these island universes? These questions are still posing a considerable challenge to present-day astronomers. Front-line observational results obtained with a fleet of ground- and space-based telescopes by an international team of astronomers [1] provide new insights into these fundamental issues. For this, they embarked on an ambitious long-term study at various wavelengths of 195 galaxies with a redshift [2] greater than 0.4, i.e. located more than 4000 million light-years away. These galaxies were studied using ESO's Very Large Telescope, as well as the

  20. Our experience in the diagnosis of aortic dissection by multislice computed tomography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis R; Mendoza Rodriguez, Vladimir; Olivares Aquiles, Eddy

    2011-01-01

    Aortic dissection (AD) is the most frequent and life-threatening acute aortic syndrome. Currently the more used method for the aortic study is the multislice computed tomography. The purpose of this paper is to expose the more relevant features in 22 patients with AD consecutively studied by multislice computed tomography

  1. Spiral branches and star formation

    International Nuclear Information System (INIS)

    Zasov, A.V.

    1974-01-01

    Origin of spiral branches of galaxies and formation of stars in them are considered from the point of view of the theory of the gravitational gas condensation, one of comparatively young theories. Arguments are presented in favour of the stellar condensation theory. The concept of the star formation of gas is no longer a speculative hypothesis. This is a theory which assumes quantitative verification and explains qualitatively many facts observed. And still our knowledge on the nature of spiral branches is very poor. It still remains vague what processes give origin to spiral branches, why some galaxies have spirals and others have none. And shapes of spiral branches are diverse. Some cases are known when spiral branches spread outside boundaries of galaxies themselves. Such spirals arise exclusively in the region where there are two or some interacting galaxies. Only first steps have been made in the explanation of the galaxy spiral branches, and it is necessary to carry out new observations and new theoretical calculations

  2. Global extinction in spiral galaxies

    NARCIS (Netherlands)

    Tully, RB; Pierce, MJ; Saunders, W; Verheijen, MAW; Witchalls, PL

    Magnitude-limited samples of spiral galaxies drawn from the Ursa Major and Pisces Clusters are used to determine their extinction properties as a function of inclination. Imaging photometry is available for 87 spirals in the B, R, I, and K' bands. Extinction causes systematic scatter in

  3. Computed gray levels in multislice and cone-beam computed tomography.

    Science.gov (United States)

    Azeredo, Fabiane; de Menezes, Luciane Macedo; Enciso, Reyes; Weissheimer, Andre; de Oliveira, Rogério Belle

    2013-07-01

    Gray level is the range of shades of gray in the pixels, representing the x-ray attenuation coefficient that allows for tissue density assessments in computed tomography (CT). An in-vitro study was performed to investigate the relationship between computed gray levels in 3 cone-beam CT (CBCT) scanners and 1 multislice spiral CT device using 5 software programs. Six materials (air, water, wax, acrylic, plaster, and gutta-percha) were scanned with the CBCT and CT scanners, and the computed gray levels for each material at predetermined points were measured with OsiriX Medical Imaging software (Geneva, Switzerland), OnDemand3D (CyberMed International, Seoul, Korea), E-Film (Merge Healthcare, Milwaukee, Wis), Dolphin Imaging (Dolphin Imaging & Management Solutions, Chatsworth, Calif), and InVivo Dental Software (Anatomage, San Jose, Calif). The repeatability of these measurements was calculated with intraclass correlation coefficients, and the gray levels were averaged to represent each material. Repeated analysis of variance tests were used to assess the differences in gray levels among scanners and materials. There were no differences in mean gray levels with the different software programs. There were significant differences in gray levels between scanners for each material evaluated (P <0.001). The software programs were reliable and had no influence on the CT and CBCT gray level measurements. However, the gray levels might have discrepancies when different CT and CBCT scanners are used. Therefore, caution is essential when interpreting or evaluating CBCT images because of the significant differences in gray levels between different CBCT scanners, and between CBCT and CT values. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  4. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  5. The perfect shape spiral stories

    CERN Document Server

    Hammer, Øyvind

    2016-01-01

    This book uses the spiral shape as a key to a multitude of strange and seemingly disparate stories about art, nature, science, mathematics, and the human endeavour. In a way, the book is itself organized as a spiral, with almost disconnected chapters circling around and closing in on the common theme. A particular strength of the book is its extremely cross-disciplinary nature - everything is fun, and everything is connected! At the same time, the author puts great emphasis on mathematical and scientific correctness, in contrast, perhaps, with some earlier books on spirals. Subjects include the mathematical properties of spirals, sea shells, sun flowers, Greek architecture, air ships, the history of mathematics, spiral galaxies, the anatomy of the human hand, the art of prehistoric Europe, Alfred Hitchcock, and spider webs, to name a few.

  6. Low-dose multislice CT in febrile neutropenic patients

    International Nuclear Information System (INIS)

    Wendel, F.; Jenett, M.; Hahn, D.; Sandstede, J.; Geib, A.

    2005-01-01

    Purpose: to define the value of low-dose multislice CT in a clinical setting for early detection of pneumonia in neutropenic patients with fever of unknown origin. Materials and methods: thirty-five neutropenic patients suffering from fever of unknown origin with normal chest X-ray underwent unenhanced low-dose CT of the chest (120 kV, 10 eff. mAs, collimation 4 x 1 mm) using a multislice CT scanner. Axial und frontal slices with a thickness of 5 mm were calculated. If no pneumonia was found, standard antibiotics were given and a repeated examination was performed if fever continued. In case of pneumonia, antimycotic therapy was added and a follow-up CT was performed within one week. Regression or progression of pneumonia at follow-up served as evidence of pneumonia; lowering of fever within 48 h or inconspicuous follow-up CT was regarded as absence of pneumonia. Results: ten of 35 patients had pneumonic infiltration, which decreased or increased on follow-up CT in 3 and 6 patients, respectively. One patient revealed leucemic infiltration by bronchoalveolar lavage. Twenty-five of 35 patients had no evidence of pneumonia. Twenty of these patients were free of fever within 48 h under antibiotics; one patient died due to his basic illness. Out of 4 patients with persisting fever, 3 patients had no pneumonia on repeated examination; one patient showed disseminated micronodular infiltration. Frontal reconstructions helped to differentiate infiltration from atelectasis in 4 patients. Sensitivity and specificity for the detection of pneumonia at the first examination were 90% and 96%, negative predictive value was 96%. Conclusion: low-dose multislice CT should be performed in neutropenic patients having a fever of unknown origin and normal chest X-ray. (orig.)

  7. A multislice theory of electron inelastic scattering in a solid

    International Nuclear Information System (INIS)

    Wang, Z.L.

    1989-01-01

    A multislice theory is proposed to solve Yoshioka's coupling equations for elastic and inelastic scattered high-energy electrons in a solid. This method is capable, in principle, of including the non-periodic crystal structures and the electron multiple scattering among all the excited states in the calculations. It is proved that the proposed theory for calculating the energy-filtered inelastic images, based on the physical optics approach, is equivalent to the quantum-mechanical theory under some approximations. The basic theory of simulating the energy-filtered inelastic image of core-shell losses and thermal diffuse scattering is outlined. (orig.)

  8. Lopsided spiral galaxies

    International Nuclear Information System (INIS)

    Jog, Chanda J.; Combes, Francoise

    2009-01-01

    The light distribution in the disks of many galaxies is 'lopsided' with a spatial extent much larger along one half of a galaxy than the other, as seen in M101. Recent observations show that the stellar disk in a typical spiral galaxy is significantly lopsided, indicating asymmetry in the disk mass distribution. The mean amplitude of lopsidedness is 0.1, measured as the Fourier amplitude of the m=1 component normalized to the average value. Thus, lopsidedness is common, and hence it is important to understand its origin and dynamics. This is a new and exciting area in galactic structure and dynamics, in contrast to the topic of bars and two-armed spirals (m=2) which has been extensively studied in the literature. Lopsidedness is ubiquitous and occurs in a variety of settings and tracers. It is seen in both stars and gas, in the outer disk and the central region, in the field and the group galaxies. The lopsided amplitude is higher by a factor of two for galaxies in a group. The lopsidedness has a strong impact on the dynamics of the galaxy, its evolution, the star formation in it, and on the growth of the central black hole and on the nuclear fuelling. We present here an overview of the observations that measure the lopsided distribution, as well as the theoretical progress made so far to understand its origin and properties. The physical mechanisms studied for its origin include tidal encounters, gas accretion and a global gravitational instability. The related open, challenging problems in this emerging area are discussed

  9. Arsia Mons Spiral Cloud

    Science.gov (United States)

    2002-01-01

    One of the benefits of the Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) Extended Mission is the opportunity to observe how the planet's weather changes during a second full martian year. This picture of Arsia Mons was taken June 19, 2001; southern spring equinox occurred the same day. Arsia Mons is a volcano nearly large enough to cover the state of New Mexico. On this particular day (the first day of Spring), the MOC wide angle cameras documented an unusual spiral-shaped cloud within the 110 km (68 mi) diameter caldera--the summit crater--of the giant volcano. Because the cloud is bright both in the red and blue images acquired by the wide angle cameras, it probably consisted mostly of fine dust grains. The cloud's spin may have been induced by winds off the inner slopes of the volcano's caldera walls resulting from the temperature differences between the walls and the caldera floor, or by a vortex as winds blew up and over the caldera. Similar spiral clouds were seen inside the caldera for several days; we don't know if this was a single cloud that persisted throughout that time or one that regenerated each afternoon. Sunlight illuminates this scene from the left/upper left.Malin Space Science Systems and the California Institute of Technology built the MOC using spare hardware from the Mars Observer mission. MSSS operates the camera from its facilities in San Diego, CA. The Jet Propulsion Laboratory's Mars Surveyor Operations Project operates the Mars Global Surveyor spacecraft with its industrial partner, Lockheed Martin Astronautics, from facilities in Pasadena, CA and Denver, CO.

  10. Polarization study of spiral galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Ward-Thompson, D

    1987-01-01

    Optical polarimetry results are presented for four spiral galaxies: NGC 5194 (M51), NGC 1068, NGC 4565 and NGC 4594 (M104). M51 and NGC 1068 show spiral polarization patterns interpreted as indicating a spiral magnetic field in each case. NGC 4565 and M104 show polarizations in their dust lanes which are parallel to their galactic planes, and which are interpreted in terms of a magnetic field in the plane of each. It is hypothesized that the observed magnetic fields may be linked to galactic shocks. A discussion of the origin of galactic magnetic fields concludes that there is not evidence that necessitates a primordial magnetic field.

  11. Spiral phases of doped antiferromagnets

    International Nuclear Information System (INIS)

    Shraiman, B.I.; Siggia, E.D.

    1990-01-01

    The dipole density field describing the holls in a doped antiferromagnet is considered for law hole density in the semiclassical limit. This yields a phase in which the order parameter is planar and spirals round a fixed direction. The single spiral state breaks the continuous spin rotational symmetry and exhibits long-range order at zero temperature. In it there is a global spin direction as rotation axis. The double spiral state, in which there are two perpendicular directions, is isotropic in both spin and real space. Several results of microscopic calculations, carried out to understand the electronic states, quantum fluctuations, lattice effects and normal mode dynamics, are recapitulated. 8 refs

  12. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  13. Spiral-shaped disinfection reactors

    KAUST Repository

    Ghaffour, NorEddine; Ait-Djoudi, Fariza; Naceur, Wahib Mohamed; Soukane, Sofiane

    2015-01-01

    This disclosure includes disinfection reactors and processes for the disinfection of water. Some disinfection reactors include a body that defines an inlet, an outlet, and a spiral flow path between the inlet and the outlet, in which the body

  14. Motion estimation and compensation in dynamic spiral CT reconstruction

    International Nuclear Information System (INIS)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St.

    2004-01-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  15. Spiral-shaped disinfection reactors

    KAUST Repository

    Ghaffour, Noreddine

    2015-08-20

    This disclosure includes disinfection reactors and processes for the disinfection of water. Some disinfection reactors include a body that defines an inlet, an outlet, and a spiral flow path between the inlet and the outlet, in which the body is configured to receive water and a disinfectant at the inlet such that the water is exposed to the disinfectant as the water flows through the spiral flow path. Also disclosed are processes for disinfecting water in such disinfection reactors.

  16. Evaluation of gastrointestinal stromal tumors by multislice computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Porto, Fabiano Elias; Baroni, Ronaldo Hueb; Rocha, Manoel de Souza; Funari, Marcelo Buarque de Gusmao; Macedo, Antonio Luiz de Vasconcellos; Pelizon, Christina Helena de Toledo

    2005-01-01

    This article presents three cases of gastrointestinal stromal tumors with clinical manifestations and pathological features, along with differential diagnoses, with special emphasis on multislice computed tomography and magnetic resonance imaging findings. (author)

  17. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  18. Diagnosis of pelvic wall tumor on multislice CT

    International Nuclear Information System (INIS)

    Zhang Keyun; Deng Lequn; Lei Hongwei

    2011-01-01

    Objective: To evaluate the value of multi-slice CT (MSCT) in diagnosing pelvic wall tumors. Methods: MSCT of 21 cases of pelvic wall tumors including metastasis (10), neurogenic tumor (5), chondrosarcoma (2), chordoma (1), aneurysmal bone cyst (1), giant cell tumor (1), and osteochondroma (1) was retrospectively analyzed. Results: CT appearances of pelvic wall tumors include bony destruction and soft tissue masses. Common features were bone destruction in metastasis, expansion of the neuroforamen in neurogenic tumor, pleomorphic calcification in chondrosarcoma, lower sacral vertebral location of chordoma, iliac crest bone destruction in giant cell tumor, cauliflower-like nodules in osteochondroma. Conclusion: MSCT with three-dimensional volume rendering demonstrates well the tumor shape, size, extent, internal structure and relationship with the surrounding organs to aid diagnosis of pelvic wall tumors. (authors)

  19. Cardiac motion extraction and characterization in multislice computed tomography

    International Nuclear Information System (INIS)

    Simon, A.

    2005-12-01

    Cardiac kinetics analysis is of a great diagnostic interest in the fight against cardiovascular pathologies. Two methods are proposed in order to estimate cardiac motion from dynamic sequences of three-dimensional volumes acquired in multislice computed tomography. These methods both lie on a feature matching process, carried out within a Markovian framework and according to a multi-resolution scheme. The first method, estimating the correspondences between pre-segmented surfaces, is dependent on the temporal coherence of this segmentation. The second method estimates the correspondences between, on the one hand, a segmented surface and, on the other hand, the original data volume corresponding to the next moment. The motion estimation and the segmentation are then carried out, on the whole sequence, during a single process. Both methods are validated on simulated and real data. (author)

  20. 64-slice spiral CT coronary angiography with prospective electrocardiogram-gating: an initial study

    International Nuclear Information System (INIS)

    Yuan Xuchun; Wang Xianzhu; Liao Wenling; Chen Qin; Deng Huiyi

    2008-01-01

    Objective: To evaluate the feasibility of prospective electrocardiogram (ECG)-gating computed tomography coronary angiography (CTCA). Methods: Sixty patients with suspected or known coronary artery disease underwent 64-slice CTCA using prospective ECG-gating. Multi-planar reconstruction ( MPR), curved-planar reconstruction (CPR), maximum intensity projection (MIP) and volume rendering (VR) were used to demonstrate the coronary arteries. The image quality and radiation dose was evaluated. Results: The mean effective radiation dose was (2.7±0.2) mSv. 93.3% (720/772) segments of all coronary arteries were of diagnostic image quality, 44.2% (341/772)was classified as excellent and 49.1% (379/772)was good. Non-diagnostic coronary segments were found in 6.7% (52/772) of all coronary arteries. There were 5(8.3%) cases with severe coronary stenosis(>75%) or occlusion, 17 (28.4%) cases with moderate stenosis (50%-75%), 18 (30.0%) cases with mild stenosis (<50% )or irregular lumen, 20(33.3%) cases with normal coronary, artery. Conclusion: With a low radiation dose, prospective electrocardiogram (ECG)-gated coronary 64-MSCT angiography has a good potential for the detection of coronary stenosis, especially for excluding coronary artery disease. (authors)

  1. Multislice helical CT in the diagnosis of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Yang Li; Zhao Shaohong; Nie Yongkang; Zhao Hong; Fang Jie; Cai Zulong; Yang Zhou; Ying Yifeng

    2005-01-01

    Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast enhancement scans, respectively ( P < 0105 ) 1 The tumor involving the bile duct was enhanced most remarkablely on 25 s phase, and the bile duct wall thickening, bile duct narrowing or occlusion were demonstrated as the p rimary findings of hilar cholangiocarcinoma1 The intraductal sp read of tumor could be demonstrated as small nodules on the bile duct wall p roximal or distal to the tumor1 Conclusion. The tumor involving the bile duct can be enhanced most remarkablely on 25 s phase after contrast injection1 Multislice helical CT, especially 3D reconstructed images, can be used to detect the direct findings of hilar cholangiocarcinomas and the extension of tumor involving the bile duct. (authors)

  2. Orientation decoding: Sense in spirals?

    Science.gov (United States)

    Clifford, Colin W G; Mannion, Damien J

    2015-04-15

    The orientation of a visual stimulus can be successfully decoded from the multivariate pattern of fMRI activity in human visual cortex. Whether this capacity requires coarse-scale orientation biases is controversial. We and others have advocated the use of spiral stimuli to eliminate a potential coarse-scale bias-the radial bias toward local orientations that are collinear with the centre of gaze-and hence narrow down the potential coarse-scale biases that could contribute to orientation decoding. The usefulness of this strategy is challenged by the computational simulations of Carlson (2014), who reported the ability to successfully decode spirals of opposite sense (opening clockwise or counter-clockwise) from the pooled output of purportedly unbiased orientation filters. Here, we elaborate the mathematical relationship between spirals of opposite sense to confirm that they cannot be discriminated on the basis of the pooled output of unbiased or radially biased orientation filters. We then demonstrate that Carlson's (2014) reported decoding ability is consistent with the presence of inadvertent biases in the set of orientation filters; biases introduced by their digital implementation and unrelated to the brain's processing of orientation. These analyses demonstrate that spirals must be processed with an orientation bias other than the radial bias for successful decoding of spiral sense. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Multislice helical computed tomography in the evaluation of lumbar spine diseases; Tomografia computadorizada 'multislice' no diagnostico das afeccoes da coluna lombar

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil)]. E-mail: laercio@einstein.br; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem

    2003-06-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  4. Origins of galactic spiral structures

    International Nuclear Information System (INIS)

    Piddington, J.H.

    1978-01-01

    Theories of galactic structure are reviewed briefly before comparing them with recent observations. Also reviewed is the evidence for an intergalactic magnetic field and its possible effects on gas concentrations and patterns of star creation, including spiral arms. It is then shown that normal spiral galaxies may be divided into the M51-type and others. The rare M51-type have H I gas arms coincident with unusually filamentary and luminous optical arms; they also have a companion galaxy. The remaining great majority of spirals have no well-defined gas arms and their optical arms are irregular, broader and less luminous; they have no companion galaxy. It appears that without exception the half-dozen or so galaxies whose structures appear to support the density-wave theory show one or more of the characteristics of the rare type of spiral, and that 'the three principal confirmations of the spiral-wave idea' (M51, M81, M101) have companions which may account for their arms. Toomre has rejected this idea on the grounds that his models do not agree with the observed structures. It is shown that these models are inadequate in two major respects, and when replaced by magneto-tidal models using non-uniform gas disks one might expect agreement. The original hydromagnetic model of spiral arms is now reserved for non-interacting galaxies, of which M33 might be taken as a prototype. The model predicts broad or 'massive' optical arms and no corresponding arms of neutral hydrogen, as observed. (Auth.)

  5. Dark matter in spiral galaxies

    International Nuclear Information System (INIS)

    Persic, M.; Salucci, P.

    1990-01-01

    The Tully-Fisher relation is used to probe dark matter (DM) in the optical regions of spiral galaxies. By establishing it at several different isophotal radii in an appropriate sample of 58 galaxies with good B-band photometry and rotation curves, it is shown that some of its attributes (such as scatter, residuals, nonlinearity, and bias) dramatically decrease moving from the disk edge inward. This behavior challenges any mass model which assumes no DM or a luminosity-independent DM mass fraction interior to the optical radius of spiral galaxies. 58 refs

  6. Application of multislice spiral CT (MSCT) in multiple injured patients and its effect on diagnostic and therapeutic algorithms

    International Nuclear Information System (INIS)

    Boehm, T.; Alkadhi, H.; Schertler, T.; Baumert, B.; Roos, J.; Marincek, B.; Wildermuth, S.

    2004-01-01

    The initial diagnostic work-up of trauma victims with multiple injuries is currently a combination of conventional radiography (CR), ultrasound (US), and computed tomography (CT). This article reviews the diagnostic quality of the different imaging modalities regarding detection and classification of injuries. CT performs better than US in detecting traumatic lesions of abdominal parenchymal organs. Furthermore, CT is better than CR in detecting therapeutically relevant chest and bone injuries. MSCT may replace CR and US under the condition that it is faster than or at least as fast as the conventional approach to diagnose lite threatening injuries. This can be achieved only by changing the work-flow for the entire trauma team including radiologist. Furthermore, certain prerequisites must be fulfilled including integration of a MSCT scanner into the emergency room. An optimized whole body CT protocol for the assessment of trauma victims using MSCT as well as a two-step algorithm for reporting the imaging findings depending on their clinical significance is presented. (orig.)

  7. Multi-slice spiral CT of the coronary arteries: improved vessel presentation by means of a standard software

    International Nuclear Information System (INIS)

    Schmitt, R.; Froehner, S.; Coblenz, G.; Christopoulos, G.; Brunn, J.; Mueller, M.; Kerber, S.; Fellner, F.

    2001-01-01

    Material and methods: Image data of 151 patients suffering from coronary artery disease were calculated by means of retrospective triggering at four different diastolic delay times in contrast-enhanced CT. The large coronary segments were subsequently reconstructed in two planes with multiplanar volume reconstruction (MPVR). Results: On the pre-condition that data sets were acquired at sinus rhythm and at a heart beat rate lower than 65/min coronary arteries could be depicted over a long distance in single or double angulated reconstruction planes with the help of MPVR. Time consumption for image reconstruction was reasonable. Additionally to the anatomy of the coronary arteries in two different planes, typical CT findings in occluding coronary artery disease are presented. (orig.) [de

  8. Multi-slice spiral CT multiplanar reconstruction findings of localized fat collection adjection to the subdiaphragmatic inferior vena cava

    International Nuclear Information System (INIS)

    Cao Hetao; Lu Jian; Zhao Jinli; Liu Tingting; Qin Jufeng; Xu Wen; Qin Jiangchun; Jiang Junkang

    2012-01-01

    Objective: To discusses the MSCT multiplanar reconstruction manifestation (MPR) of localized fat collection adjection to subdiaphragmatic inferior vena cava (IVC fat ). Methods: The thoracic and abdominal MSCT scan data of 8246 patients were browsed,45 patients with presumed IVC fat on axial CT scans were further studied prospectively with MSCT MPR. The predisposing position of IVC fat and its relationship with IVC were observed. It was divided into two kinds of intraluminal type and extraluminal type according to the angle of IVC fat with respect of the wall of IVC.The other 50 patients without IVC fat were randomly selected as the control group. The sagittal inclination angle (SIA) and diameter ratio (DR) between supra- and sub-diaphragmatic IVC between the two groups were compared by using t test. Results: The detection rate was 0.55% (45/8246). Of which hepatic vein lacuna 8 patients, subdiaphragmatic gap medial to IVC 28 patients and IVC groove 9 patients. The shape of IVC fat showed mainly for the round, oval and crescents on axial CT scans, of 15 patients intraluminal type, 4 showed 'target signs'. The shape of IVC fat showed mainly for 'half-moon' at MPR.The SIA and DR at IVC fat group were 21.62° ± 8.42° and 2.01 ±0.84 respectively, at control group were 16.75° ±7.82° (t=1.594, P>0.05) and 1.31 ±0.28 (t=2.341, P<0.05) respectively. Conclusion: The round, oval or half of limited fat density shadow adjection to subdiaphragmatic inferior vena cava which similar to in the lumen is the characteristic performance of IVC fat , it may be an anatomical variation. (authors)

  9. The experimental study and clinical application on the detection of pulmonary nodules with low-dose multislice spiral CT

    International Nuclear Information System (INIS)

    Wu Xiaohua; Ma Daqing; Zhang Zhongjia; Ji Jingling; Zhang Yansong

    2004-01-01

    Objective: To investigate the detection rate of pulmonary nodules ,especially nodules ≤5 mm, in variable low-doses, and to evaluate the imaging quality of low-dose MSCT. Methods: Six postmortem specimens of patients with pneumoconiosis after necropsy were fixed at end-inspiratory volume. The fixed specimens were examined by using MSCT with standard dose (130 mA) and low-dose (50, 30, 10 mA, respectively). Low-dose MSCT scans of 40 asymptomatic volunteers and 60 patients with pulmonary metastasis were also examined with 30 mA. The numbers of pulmonary nodules less than 5 mm at standard-dose and different low-dose were recorded. Nodules were assessed by diagnostic confidence ('definite nodule', 'questionable nodule', and 'definite not nodule'). The number of images with artifact in specimens and in 40 volunteers and 60 patients with pulmonary metastasis were recorded. Results: In specimen's study, the Kappa values of groups of low-dose (50, 30, 10 mA) were 0.515, 0.242, and 0.154, respectively. The group of 50 mA had a good coincidence with standard-dose group by U test. The sensitivity of group 50, 30, 10 mA was 88.0%, 78.4%, and 75.0%, respectively. The positive predictive values of which were 98%, 94%, and 93%, respectively. The correction rates of which were 85%, 73%, and 69%, respectively. In specimens' images, subtle linear artifact was showed only in paravertebral lung field in 21 images of 31 at the group of 10 mA. Linear artifacts that affected small nodule detection were showed in lung apexes in 3 of 100 subjects. Conclusion: Low-dose MSCT is expected to improve early detection of lung cancer. Pulmonary nodules less than 5 mm could be reliably detected at 50 mA tube current in specimens. Low-dose CT (30 mA) showed satisfactory imaging quality in our study. Low-dose CT screening for lung cancer may be applied if situation permits. (authors)

  10. Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience

    International Nuclear Information System (INIS)

    De Lutio di Castelguidone, Elisabetta; Pinto, Antonio; Merola, Stefanella; Stavolo, Ciro; Romano, Luigia

    2005-01-01

    Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of oesophageal perforation: peri-oesophageal air (5 cases), peri-oesophageal fluid (4 cases), oesophageal wall thickening (3 cases), oesophageal wall laceration (2 cases) with abnormal course of the nasogastric tube in one of them and extraluminal extravasation of oral contrast material (2 cases). In two patients with post-intubation complications, CT showed the presence of a small peri-oesophageal fluid collection containing small gas bubbles in one case, and a gross peri-oesophageal abscess-like collection in the second case. In the 2 patients with foreign body ingestion, the plain radiography associated with CT showed the presence of a thin metal object in the cervical region (fragment of a dental plate) and a small extraluminal extravasation of gastrografin in one case, whereas in the other case CT showed the presence of a foreign body (chicken bone) in the hypopharynx with oesophageal wall thickening and peri-oesophageal oedema. In the remaining three patients with suspected spontaneous oesophageal perforation, CT showed the presence of a intramural haematoma in one case, oesophageal fluid distension with gas and a small peri-oesophageal fluid effusion (Mallory-Weiss syndrome) in another, and oesophageal rapture (Boerhaave syndrome) in the last case. Conclusions: Our experience shows that in patients with suspected traumatic and spontaneous oesophageal perforation, standard cervical and chest radiography may suggest a suspected oesophageal perforation in only a small proportion of cases, whereas oral contrast oesophagography has a higher sensitivity. Through the careful analysis of suggestive and specific signs of oesophageal perforation, a correct CT examination enables an accurate and timely diagnosis which significantly affects prognosis and provides valuable indications for treatment [it

  11. The value of multi-slice spiral CT liver perfusion imaging to evaluate the chronic hepatic fibrosis and cirrhosis

    International Nuclear Information System (INIS)

    Long Liling; Huang Zhongkui; Ding Ke; Liao Jinyuan; Jiang Jianning

    2012-01-01

    Objective: To investigate the value of the MSCT liver perfusion imaging parameters in the evaluation of the chronic hepatic fibrosis and cirrhosis. Methods: Liver CT perfusion (CTP) was performed in 107 participants,including 31 patients with mild hepatic fibrosis (S1, S2), 34 patients with severe hepatic fibrosis (S3, S4) and early stage of hepatic cirrhosis which conformed by liver pathologic biopsy, 42 patients with hepatic cirrhosis who had typical clinical and image signs, and 30 healthy subjects as control group. The data of CTP (HAP, PVP, LTP, HPI and TTP) at different stages were obtained with Body perfect CT-syngo CT2007A and control study with histopathologic stage. Compared the study index by the one-way ANOVA analysis. Used Spearman rank correlation to analysis the relationship between liver perfusion imaging parameters and the degrees of the chronic hepatic fibrosis. Used Logistic regression to analysis the maximum regression coefficient among the liver perfusion imaging parameters, which affected the histopathologic stage mostly. Results: In the subgroups of the chronic hepatic fibrosis S1, S2, S3, S4 to the hepatic cirrhosis,HAP values was (28.9 ±8.6), (24.6 ±2.4), (29.2 ±2.3) and (38.9 ± 7.0) ml · 100 ml -1 · min -1 , respectively. HAP decreased firstly,then increased. Statistic analysis showed the difference of HAP between later-stage cirrhosis and other groups (F=40.26, P<0.01). PVP values of above subgroups was (111.3 ± 18.1), (92.9 ±5.3), (73.0 ±9.0) and (54.1 ± 13.8) ml · 100 ml -1 ·min -1 , respectively. TLP values of above subgroups was (140.2 ± 25.9), (117.1 ± 4.5), (102.3 ± 8.7)and (93.0 ± 11.8) ml · 100 ml -1 ·min -1 , respectively. The difference of PVP, TLP among each subgroup was significant (F=136.79, 67.40, respectively, P<0.01). HPI values of above subgroups was (20.4 ± 2.6)%, (21.0 ±2.1)%, (28.5 ±3.1)% and (42.6± 11.1)%, respectively. TTP values of above subgroups was (123.7±22.2), (137.1 ±27.1), (145.0 ±28.6) and (166.5 ±25.1)s, respectively. The difference of HPI, TTP among each subgroup was significant (F=93.05, 17.37, respectively; P<0.01). PVP, TLP was significant negative correlation with the degree of the hepatic fibrosis (r=-0.920, -0.846, respectively; P<0.01). HAP, HPI and TTP was significant positive correlation with the degree of the hepatic fibrosis (r=0.611, 0.882 and 0.545, respectively; P<0.01). Logistic regression analysis showed the regression coefficient of PVP (-8.798) was maximum.With an area under the receiver operating characteristic curve of PVP =84.76 ml · 100 ml -1 · min -1 as a diagnose critical point. The sensitivity was 0.890, the specificity was 0.950, and the accuracy was 0.931 in the prediction of the chronic hepatic fibrosis. Conclusions: MSCT liver perfusion imaging parameters can reflect the hemodynamic changes of chronic hepatic fibrosis and cirrhosis. CTP may be helpful for differentiation the severe hepatic fibrosis and early stage of hepatic cirrhosis and later-stage cirrhosis. (authors)

  12. Multi-slice spiral CT in the diagnosis of congenital heart diseases associated with tracheobronchial stenosis in children

    International Nuclear Information System (INIS)

    Wang Rongpin; Liang Changhong; Huang Meiping; Liu Hui; Cui Yanhai; Liu Qishun

    2010-01-01

    Objective: To explore the diagnostic value of post processing techniques of MSCT for diagnosing congenital heart disease associated with tracheobronchial stenosis in children. Methods: Thirty four patients with congenital heart disease complicated by tracheobronchial stenosis were evaluated with MSCT. MPR, CPR, MinIP and VR were performed to show the tracheobronchial morphology. Findings in 43 segments of 32 cases were compared with the findings of surgical operation. Mann-Whitney test was employed to assess the significance of measurement between the post processing techniques and the operation. Results: The length of stenotic segments were variable seen at operation, with values between 4- 39 mm in trachea, 4-33 mm in main bronchi and 3-12 mm in lobe bronchi, respectively. The biggest difference between the measurement of operation and MSCT was 4 mm (3 segments). Other differences of stenotic segments were within 3 mm. Six segments exhibited mild, 16 moderate and 21 severe stenosis at surgery. By contrast, five segments exhibited mild, 17 moderate and 21 severe stenosis by MPR or CPR, 2 mild, 9 moderate and 32 severe stenosis by MinIP and 4 mild, 11 moderate and 28 sever stenosis by VR, respectively. There was no significant difference in measuring the degree of tracheobronchial stenosis between MPR or CPR, VR and the surgery (Z=-0.105, -1.479; P>0.05), while MinIP frequently overrated the degree of stenosis compared with the measurement at surgery (Z=-2.484, P=0.013). Conclusion: The integrated three dimensional reformations of MSCT scan can accurately evaluate the degree and extent of congenital heart disease associated with tracheobronchial stenosis in children and provide valuable information for clinical management. (authors)

  13. Incorporating multislice imaging into x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H., E-mail: holly.johnston@utsw.edu [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2 (Canada); Hilts, M. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Medical Physics, BC Cancer Agency, Vancouver Island Centre, Victoria, British Columbia V8R 6V5 (Canada); Jirasek, A. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Department of Physics, University of British Columbia—Okanagan Campus, Kelowna, British Columbia V1V 1V7 (Canada)

    2015-04-15

    Purpose: To evaluate multislice computed tomography (CT) scanning for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD) and to establish a baseline assessment of image noise and uniformity in an unirradiated gel dosimeter. Methods: A 16-slice CT scanner was used to acquire images through a 1 L cylinder filled with water. Additional images were collected using a single slice machine. The variability in CT number (N{sub CT}) associated with the anode heel effect was evaluated and used to define a new slice-by-slice background subtraction artifact removal technique for CT PGD. Image quality was assessed for the multislice system by evaluating image noise and uniformity. The agreement in N{sub CT} for slices acquired simultaneously using the multislice detector array was also examined. Further study was performed to assess the effects of increasing x-ray tube load on the constancy of measured N{sub CT} and overall scan time. In all cases, results were compared to the single slice machine. Finally, images were collected throughout the volume of an unirradiated gel dosimeter to quantify image noise and uniformity before radiation is delivered. Results: Slice-by-slice background subtraction effectively removes the variability in N{sub CT} observed across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image noise was higher for the multislice system compared to the single slice scanner, but overall image quality was comparable between the two systems. Further study showed N{sub CT} was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thicknesses examined. In addition, the multislice system was found to eliminate variations in N{sub CT} due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to

  14. Quasicrystallography on the spiral of Archimedes

    International Nuclear Information System (INIS)

    Bursill, L.A.

    1990-01-01

    The concept of a spiral lattice is discussed. Some examples of known mineral structures, namely clino asbestos, halloysite and cylindrite, are then interpreted in terms of this structural principle. An example of a synthetic sulphide catalyst spiral structure having atomic dimensions is also described. All of these inorganic spiral structures are based on the sprial of Archimedes. The principles for a new type of crystallography, based on the Archimedian spiral, are then presented. 45 refs., 8 figs

  15. A study of spiral galaxies

    International Nuclear Information System (INIS)

    Wevers, B.M.H.R.

    1984-01-01

    Attempts have been made to look for possible correlations between integral properties of spiral galaxies as a function of morphological type. To investigate this problem, one needs the detailed distribution of both the gaseous and the stellar components for a well-defined sample of spiral galaxies. A sample of about 20 spiral galaxies was therefore defined; these galaxies were observed in the 21 cm neutral hydrogen line with the Westerbork Synthesis Radio Telescope and in three broad-band optical colours with the 48-inch Palomar Smidt Telescope. First, an atlas of the combined radio and optical observations of 16 nearby northern-hemisphere spiral galaxies is presented. Luminosity profiles are discussed and the scale lengths of the exponential disks and extrapolated central surface brightnesses are derived, as well as radial color distributions; azimuthal surface brightness distributions and rotation curves. Possible correlations with optical features are investigated. It is found that 20 to 50 per cent of the total mass is in the disk. (Auth.)

  16. The Spiral Pattern During Development*

    African Journals Online (AJOL)

    1971-08-07

    Aug 7, 1971 ... which are destined to become the limb areas bud out laterally. Fig. 8. The early cells, which are destined to develop into the upper and the lower limbs, after lateral budding has occurred. Fig. 11 demonstrates the human embryo of about 5 mm. CR length and age of about 32 days. The spiral pattern is.

  17. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  18. Optimization of pediatric examinations in a multislice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Ombada, T H. A. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI{sub v}ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI{sub v}ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  19. TESTING THEORIES IN BARRED-SPIRAL GALAXIES

    International Nuclear Information System (INIS)

    Martínez-García, Eric E.

    2012-01-01

    According to one version of the recently proposed 'manifold' theory that explains the origin of spirals and rings in relation to chaotic orbits, galaxies with stronger bars should have a higher spiral arms pitch angle when compared to galaxies with weaker bars. A subsample of barred-spiral galaxies in the Ohio State University Bright Galaxy Survey was used to analyze the spiral arms pitch angle. These were compared with bar strengths taken from the literature. It was found that the galaxies in which the spiral arms maintain a logarithmic shape for more than 70° seem to corroborate the predicted trend.

  20. Interaction of multiarmed spirals in bistable media.

    Science.gov (United States)

    He, Ya-feng; Ai, Bao-quan; Liu, Fu-cheng

    2013-05-01

    We study the interaction of both dense and sparse multiarmed spirals in bistable media modeled by equations of the FitzHugh-Nagumo type. A dense one-armed spiral is characterized by its fixed tip. For dense multiarmed spirals, when the initial distance between tips is less than a critical value, the arms collide, connect, and disconnect continuously as the spirals rotate. The continuous reconstruction between the front and the back drives the tips to corotate along a rough circle and to meander zigzaggedly. The rotation frequency of tip, the frequency of zigzagged displacement, the frequency of spiral, the oscillation frequency of media, and the number of arms satisfy certain relations as long as the control parameters of the model are fixed. When the initial distance between tips is larger than the critical value, the behaviors of individual arms within either dense or sparse multiarmed spirals are identical to that of corresponding one-armed spirals.

  1. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ming, W.Q.; Chen, J.H., E-mail: jhchen123@hnu.edu.cn

    2013-11-15

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations.

  2. Validities of three multislice algorithms for quantitative low-energy transmission electron microscopy

    International Nuclear Information System (INIS)

    Ming, W.Q.; Chen, J.H.

    2013-01-01

    Three different types of multislice algorithms, namely the conventional multislice (CMS) algorithm, the propagator-corrected multislice (PCMS) algorithm and the fully-corrected multislice (FCMS) algorithm, have been evaluated in comparison with respect to the accelerating voltages in transmission electron microscopy. Detailed numerical calculations have been performed to test their validities. The results show that the three algorithms are equivalent for accelerating voltage above 100 kV. However, below 100 kV, the CMS algorithm will introduce significant errors, not only for higher-order Laue zone (HOLZ) reflections but also for zero-order Laue zone (ZOLZ) reflections. The differences between the PCMS and FCMS algorithms are negligible and mainly appear in HOLZ reflections. Nonetheless, when the accelerating voltage is further lowered to 20 kV or below, the PCMS algorithm will also yield results deviating from the FCMS results. The present study demonstrates that the propagation of the electron wave from one slice to the next slice is actually cross-correlated with the crystal potential in a complex manner, such that when the accelerating voltage is lowered to 10 kV, the accuracy of the algorithms is dependent of the scattering power of the specimen. - Highlights: • Three multislice algorithms for low-energy transmission electron microscopy are evaluated. • The propagator-corrected algorithm is a good alternative for voltages down to 20 kV. • Below 20 kV, a fully-corrected algorithm has to be employed for quantitative simulations

  3. Multislice CT for preoperative diagnosis of pancreatic cancer

    International Nuclear Information System (INIS)

    Horiguchi, Akihiko; Ishihara, Shin; Ito, Masahiro

    2007-01-01

    We investigated the ability of multislice (MS) CT to visualize and diagnose the progression of pancreatic cancer. With regard to local progression, good diagnosis was possible for detecting the invasion of the intrapancreatic bile duct, duodenum, portal vein, arteries and other organs, and liver metastasis. Sensitivity was high but specificity was not good for detecting the invasion of the anterior and posterior pancreatic tissue. This is thought to be because of the positive diagnosis with pancreatitis that accompanies cancer. Pancreatic plexus invasion was also thought to be a cause of the lipid elevation of the nerve plexus and decreased sensitivity accompanying pancreatitis. Identification of cancer invasion and tumor periphery changes based on concomitant pancreatitis also depends on the amount of fibrous stroma, but this will require further investigation. Factors other than the size of lymph node metastases also need to be investigated. MS-CT can provide detailed volume data in a short time and making it an essential test in diagnosing the stage of pancreatic cancer. (author)

  4. Evaluation of pituitary adenomas by multidirectional multislice dynamic CT

    International Nuclear Information System (INIS)

    Abe, T.; Izumiyama, H.; Fujisawa, I.

    2002-01-01

    Purpose: Multidetector-row CT is a new technology with a short scanning time. Multislice dynamic CT (MSDCT) in various directions can be obtained using the multidetector-row CT with multiplanar reformatting (MPR) technique. Material and Methods: We evaluated the initial results of sagittal and coronal MSDCT images reconstructed by MPR (MSDCT-MPR) in 3 pituitary adenoma patients with a pacemaker. Results: In a patient with microadenoma, the maximum contrast between the normal anterior pituitary gland and the adenoma occurred approximately 50 s after the start of the contrast medium injection. A microadenoma was depicted as a less enhanced area relative to normal pituitary tissue. The macroadenomas were depicted as a less enhanced mass with cavernous sinus invasion in 1 patient and as a non-uniformly enhanced mass in another patient. Bone destruction and incomplete opening of the sellar floor during previous surgery were clearly detected in 2 patients with macroadenomas. These pituitary adenomas were removed via the transnasal route based on information from the MSDCT-MPR images only. The findings were verified surgically. Conclusion: The MSDCT-MPR provided the information needed for surgery with good image quality in the 3 patients with pacemakers. MSDCT-MPR appears to be a useful technique for patients with a pituitary adenoma in whom MR imaging is not available. This is the first report, to our knowledge, of the MSDCT-MPR technique being used to demonstrate pituitary disorders

  5. Evaluation of pituitary adenomas by multidirectional multislice dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Abe, T.; Izumiyama, H. [Showa Univ. School of Medicine, Tokyo (Japan). Dept. of Neurosurgery; Fujisawa, I. [Kishiwada City Hospital, Kishiwada (Japan). Dept. of Radiology

    2002-11-01

    Purpose: Multidetector-row CT is a new technology with a short scanning time. Multislice dynamic CT (MSDCT) in various directions can be obtained using the multidetector-row CT with multiplanar reformatting (MPR) technique. Material and Methods: We evaluated the initial results of sagittal and coronal MSDCT images reconstructed by MPR (MSDCT-MPR) in 3 pituitary adenoma patients with a pacemaker. Results: In a patient with microadenoma, the maximum contrast between the normal anterior pituitary gland and the adenoma occurred approximately 50 s after the start of the contrast medium injection. A microadenoma was depicted as a less enhanced area relative to normal pituitary tissue. The macroadenomas were depicted as a less enhanced mass with cavernous sinus invasion in 1 patient and as a non-uniformly enhanced mass in another patient. Bone destruction and incomplete opening of the sellar floor during previous surgery were clearly detected in 2 patients with macroadenomas. These pituitary adenomas were removed via the transnasal route based on information from the MSDCT-MPR images only. The findings were verified surgically. Conclusion: The MSDCT-MPR provided the information needed for surgery with good image quality in the 3 patients with pacemakers. MSDCT-MPR appears to be a useful technique for patients with a pituitary adenoma in whom MR imaging is not available. This is the first report, to our knowledge, of the MSDCT-MPR technique being used to demonstrate pituitary disorders.

  6. Multislice CT enteroclysis in the diagnosis of bowel endometriosis

    International Nuclear Information System (INIS)

    Biscaldi, Ennio; Rollandi, Gian A.; Ferrero, Simone; Ragni, Nicola; Remorgida, Valentino; Fulcheri, Ezio

    2007-01-01

    This prospective study aims to evaluate the efficacy of multislice computed tomography combined with colon distension by water enteroclysis (MSCTe) in determining the presence and depth of bowel endometriotic lesions. Ninety-eight women with symptoms suggestive of colorectal endometriosis underwent MSCTe; locations, number of nodule/s, size of the nodule/s and depth of bowel wall infiltration were determined. Independently from the findings of MSCTe, all women underwent laparoscopy. MSCTe findings were compared with surgical and histological results. Abnormal findings suggestive of bowel endometriotic nodules were detected by MSCTe in 75 of the 76 patients with bowel endometriosis. MSCTe identified 110 (94.8%) of the 116 bowel endometriotic nodules removed at surgery; 6 nodules missed at MSCTe were located on the rectum. MSCTe correctly determined the degree of infiltration of the bowel wall in all of the 34 serosal bowel nodules identified at MSCTe. In six nodules reaching the submucosa, the depth of infiltration was underestimated by MSCTe. MSCTe had a sensitivity of 98.7%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value of 95.7% in identifying women with bowel endometriosis. MSCTe is effective in determining the presence and depth of bowel endometriotic lesions. (orig.)

  7. Multislice CT enteroclysis in the diagnosis of bowel endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Biscaldi, Ennio; Rollandi, Gian A. [' ' Duchesse of Galliera' ' -Hospital, Genoa (Italy). Dept. of Radiology; Ferrero, Simone; Ragni, Nicola; Remorgida, Valentino [San Martino Hospital and Genoa Univ. (Italy). Dept. of Obstretics and Gynaecology; Fulcheri, Ezio [San Martino Hospital and Genoa Univ. (Italy). Unit of Anatomy and Histopathology

    2007-01-15

    This prospective study aims to evaluate the efficacy of multislice computed tomography combined with colon distension by water enteroclysis (MSCTe) in determining the presence and depth of bowel endometriotic lesions. Ninety-eight women with symptoms suggestive of colorectal endometriosis underwent MSCTe; locations, number of nodule/s, size of the nodule/s and depth of bowel wall infiltration were determined. Independently from the findings of MSCTe, all women underwent laparoscopy. MSCTe findings were compared with surgical and histological results. Abnormal findings suggestive of bowel endometriotic nodules were detected by MSCTe in 75 of the 76 patients with bowel endometriosis. MSCTe identified 110 (94.8%) of the 116 bowel endometriotic nodules removed at surgery; 6 nodules missed at MSCTe were located on the rectum. MSCTe correctly determined the degree of infiltration of the bowel wall in all of the 34 serosal bowel nodules identified at MSCTe. In six nodules reaching the submucosa, the depth of infiltration was underestimated by MSCTe. MSCTe had a sensitivity of 98.7%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value of 95.7% in identifying women with bowel endometriosis. MSCTe is effective in determining the presence and depth of bowel endometriotic lesions. (orig.)

  8. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  9. SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H [University of Victoria, Victoria, BC (Australia); UT Southwestern Medical Center, Dallas, TX (United States); Hilts, M [University of Victoria, Victoria, BC (Australia); BC Cancer Agency, Kelowna, BC (Australia); Jirasek, A [University of Victoria, Victoria, BC (Australia)

    2014-06-01

    Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering

  10. Low surface brightness spiral galaxies

    International Nuclear Information System (INIS)

    Romanishin, W.

    1980-01-01

    This dissertation presents an observational overview of a sample of low surface brightness (LSB) spiral galaxies. The sample galaxies were chosen to have low surface brightness disks and indications of spiral structure visible on the Palomar Sky Survey. They are of sufficient angular size (diameter > 2.5 arcmin), to allow detailed surface photometry using Mayall 4-m prime focus plates. The major findings of this dissertation are: (1) The average disk central surface brightness of the LSB galaxies is 22.88 magnitude/arcsec 2 in the B passband. (2) From broadband color measurements of the old stellar population, we infer a low average stellar metallicity, on the order of 1/5 solar. (3) The spectra and optical colors of the HII regions in the LSB galaxies indicate a lack of hot ionizing stars compared to HII regions in other late-type galaxies. (4) The average surface mass density, measured within the radius containing half the total mass, is less than half that of a sample of normal late-type spirals. (5) The average LSB galaxy neutral hydrogen mass to blue luminosity ratio is about 0.6, significantly higher than in a sample of normal late-type galaxies. (6) We find no conclusive evidence of an abnormal mass-to-light ratio in the LSB galaxies. (7) Some of the LSB galaxies exhibit well-developed density wave patterns. (8) A very crude calculation shows the lower metallicity of the LSB galaxies compared with normal late-type spirals might be explained simply by the deficiency of massive stars in the LSB galaxies

  11. Dynamical models of spiral galaxies

    International Nuclear Information System (INIS)

    Grosbol, P.

    1990-01-01

    The effects of changing the basic parameters of rotation curve steepness, amount of bulge, and pitch angle of the imposed spiral pattern in the galactic model of Contoupolos and Grosbel (1986) are investigated. The general conclusions of the model are confirmed and shown to be insensitive to the specific choice of parameters for the galactic potential. The exact amplitude at which the nonlinear effects at the 4:1 resonance become important do, however, depend on the model

  12. Multiple mechanisms quench passive spiral galaxies

    Science.gov (United States)

    Fraser-McKelvie, Amelia; Brown, Michael J. I.; Pimbblet, Kevin; Dolley, Tim; Bonne, Nicolas J.

    2018-02-01

    We examine the properties of a sample of 35 nearby passive spiral galaxies in order to determine their dominant quenching mechanism(s). All five low-mass (M⋆ environments. We postulate that cluster-scale gas stripping and heating mechanisms operating only in rich clusters are required to quench low-mass passive spirals, and ram-pressure stripping and strangulation are obvious candidates. For higher mass passive spirals, while trends are present, the story is less clear. The passive spiral bar fraction is high: 74 ± 15 per cent, compared with 36 ± 5 per cent for a mass, redshift and T-type matched comparison sample of star-forming spiral galaxies. The high mass passive spirals occur mostly, but not exclusively, in groups, and can be central or satellite galaxies. The passive spiral group fraction of 74 ± 15 per cent is similar to that of the comparison sample of star-forming galaxies at 61 ± 7 per cent. We find evidence for both quenching via internal structure and environment in our passive spiral sample, though some galaxies have evidence of neither. From this, we conclude no one mechanism is responsible for quenching star formation in passive spiral galaxies - rather, a mixture of mechanisms is required to produce the passive spiral distribution we see today.

  13. Chronic thromboembolic pulmonary hypertension: diagnostic impact of multislice-CT and selective pulmonary-DSA

    International Nuclear Information System (INIS)

    Pitton, M.B.; Kemmerich, G.; Herber, S.; Schweden, F.; Thelen, M.; Mayer, E.

    2002-01-01

    Purpose: To evaluate the diagnostic impact of multislice-CT and selective pulmonary DSA in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: 994 vessel segments of 14 consecutive patients with CTEPH were investigated with multislice-CT (slice thickness 3 mm, collimation 2.5 mm, reconstruction intervall 2 mm) and selective pulmonary DSA posterior-anterior, 45 oblique, and lateral projection. Analysis was performed by 2 investigators independently for CT and DSA. Diagnostic criteria were occlusions and non-occlusive changes like webs and bands, irregularities of the vessel wall, diameter reduction and thromboembolic depositions at different levels from central pulmonary arteries to subsegmental arteries. Reference diagnosis was made by synopsis of CT and DSA by consensus. Results: Concerning patency CT and DSA showed concordant findings overall in 88.9%, 92.9% for segmental arteries and 85.4% for subsegmental arteries. Concerning any thromboembolic changes, multislice-CT was significantly inferior to selective DSA (concordance 67.0% overall, 70.4% for segments and 63.6% for subsegments). Non-occlusive changes of the vessels were significantly underdiagnosed by CT (concordance of CT versus DSA: 23.1%). Conclusion: Multislice-CT and selective pulmonary DSA are equivalent for diagnosis of vessel occlusions at the level of segmental and subsegmental arteries. However, for visualisation of the non-occlusive thromboembolic changes of the vessel wall selective pulmonary DSA is still superior compared to multislice-CT. Multislice-CT and selective pulmonary DSA are complementary tools for diagnosis and treatment planning of chronic thromboembolic pulmonary hypertension (CTEPH). (orig.) [de

  14. Congenital abnormalities of aortic artery. Assessment in neonates and early childhood with multislice tomography

    International Nuclear Information System (INIS)

    Haberman, D.; Gurfinkel, E.; Beresnak, A.; Martinez, A.; Emsani, R.; Toledo, R.

    2009-01-01

    In the evaluation of aortic artery congenital abnormalities, the echocardiography and the plain X ray are the traditionally used imaging methods. Multislice angiotomography appears as an important method in diagnosis of these different diseases allowing evaluate these entities in a non invasive, fast and accurate form, giving to cardiovascular surgeons very important information to delineate the surgical strategy. In this article, we review the applications of multislice angiotomography in the evaluation of most frequent congenital anomalies of aorta artery, performed in neonates and early childhood. (authors) [es

  15. Multislice helical computed tomography in the evaluation of lumbar spine diseases

    International Nuclear Information System (INIS)

    Rosemberg, Laercio Alberto; Rios, Adriana Martins; Almeida, Milena Oliveira; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao

    2003-01-01

    Multislice computed tomography has advantages in comparison to conventional computer tomography such as reduction in study time, lower radiation dose, fewer metal artifacts and high quality multiplanar reformatting and three-dimensional reconstructions. We reviewed approximately 300 lumbar spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms traumatic injuries, spondylolysis and postoperative changes. In the majority of the cases the high quality multiplanar reformatted and volume reconstructions of multislice computed tomography allowed better evaluation of the lesions, particularly in the cases of complex anatomy (author)

  16. MEGACELL: A nanocrystal model construction software for HRTEM multislice simulation

    International Nuclear Information System (INIS)

    Stroppa, Daniel G.; Righetto, Ricardo D.; Montoro, Luciano A.; Ramirez, Antonio J.

    2011-01-01

    Image simulation has an invaluable importance for the accurate analysis of High Resolution Transmission Electron Microscope (HRTEM) results, especially due to its non-linear image formation mechanism. Because the as-obtained images cannot be interpreted in a straightforward fashion, the retrieval of both qualitative and quantitative information from HRTEM micrographs requires an iterative process including the simulation of a nanocrystal model and its comparison with experimental images. However most of the available image simulation software requires atom-by-atom coordinates as input for the calculations, which can be prohibitive for large finite crystals and/or low-symmetry systems and zone axis orientations. This paper presents an open source citation-ware tool named MEGACELL, which was developed to assist on the construction of nanocrystals models. It allows the user to build nanocrystals with virtually any convex polyhedral geometry and to retrieve its atomic positions either as a plain text file or as an output compatible with EMS (Electron Microscopy Software) input protocol. In addition to the description of this tool features, some construction examples and its application for scientific studies are presented. These studies show MEGACELL as a handy tool, which allows an easier construction of complex nanocrystal models and improves the quantitative information extraction from HRTEM images. -- Highlights: → A software to support the HRTEM image simulation of nanocrystals in actual size. → MEGACELL allows the construction of complex nanocrystals models for multislice image simulation. → Some examples of improved nanocrystalline system characterization are presented, including the analysis of 3D morphology and growth behavior.

  17. Dose optimization for multislice computed tomography protocols of the midface

    International Nuclear Information System (INIS)

    Lorenzen, M.; Wedegaertner, U.; Weber, C.; Adam, G.; Lorenzen, J.; Lockemann, U.

    2005-01-01

    Purpose: to optimize multislice computed tomography (MSCT) protocols of the midface for dose reduction and adequate image quality. Materials and methods: MSCT (somatom volume zoom, siemens) of the midface was performed on 3 cadavers within 24 hours of death with successive reduction of the tube current, applying 150, 100, 70 and 30 mAs at 120 kV as well as 40 and 21 mAs at 80 kV. At 120 kV, a pitch of 0.875 and collimation of 4 x 1 mm were used, and at 80 kV, a pitch of 0.7 and collimation of 2 x 0.5 mm. Images were reconstructed in transverse and coronal orientation. Qualitative image analysis was separately performed by two radiologists using a five-point scale (1 = excellent; 5 = poor) applying the following parameters: image quality, demarcation and sharpness of lamellar bone, overall image quality, and image noise (1 = minor; 5 = strong). The effective body dose [mSv] and organ dose [mSv] of the ocular lens (using the dosimetry system ''WINdose'') were calculated, and the interobserver agreement (kappa coefficient) was determined. Results: for the evaluation of the lamellar bone, adequate sharpness, demarcation and image quality was demonstrated at 120 kV/30 mAs, and for the overall image quality and noise, 120 kV/40 mAs was acceptable. With regard to image quality, the effective body dose could be reduced from 1.89 mSv to 0.34 mSv and the organ dose of the ocular lens from 27.2 mSv to 4.8 mSv. Interobserver agreement was moderate (kappa = 0.39). Conclusion: adequate image quality was achieved for MSCT protocols of the midface with 30 mAs at 120 kV, resulting in a dose reduction of 70% in comparison to standard protocols. (orig.)

  18. Myocardial bridging: evaluation with multislice computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, M.V.L. de; Rabelo, D.R.; Nunes, M.C.P.; Siqueira, M.H.A. [Mater Dei Hospital, Belo Horizonte, MG (Brazil)

    2012-04-15

    Myocardial bridging (MB) is defined as a segment of a major epicardial coronary artery that proceeds intramurally through the myocardium beneath the muscle bridge. Although MB is clinically silent in most cases, it has been associated with myocardial ischemia, myocardial infarction, arrhythmia, and sudden death. Conventional coronary angiography (CCA) is the gold standard for detection, but it is invasive and may not be sensitive enough to detect a thin bridge. Recently, multislice computed tomography coronary angiography (MCTCA) have made possible the clear detection of the entire running courses of coronary arteries and the MB itself. Objective: To evaluate the prevalence MB in patients suspect to coronary artery disease submitted to MCTCA and assessing the predictive value of this method in the midterm. Methods: 498 consecutive patients were examined by MCTCA for the diagnosis of coronary artery disease and followed for a mean follow-up of 17 months for the occurrence of cardiovascular events (death, hospitalization and / or revascularization myocardial). Results: The mean age of patients was 58.4 ± 12.5 years old, 74.3% male. Among the patients, 6,02% (30 patients) showed MB. The major indications were angina pectoris in 45,8% and positive stress testing in 33,3%. 62,5% showed absent atherosclerotic disease and only 1 patient showed moderade descending anterior stenosis. During the follow-up none patient showed hard events. Conclusion: Patients with MB could present with angina pectoris and positive stress testing and showed midterm excellent prognosis. MCTCA is an alternative noninvasive imaging tool that allows for easy and accurate evaluation of MB.

  19. Collective excitations in itinerant spiral magnets

    International Nuclear Information System (INIS)

    Kampf, A.P.

    1996-01-01

    We investigate the coupled charge and spin collective excitations in the spiral phases of the two-dimensional Hubbard model using a generalized random-phase approximation. Already for small doping the spin-wave excitations are strongly renormalized due to low-energy particle-hole excitations. Besides the three Goldstone modes of the spiral state the dynamical susceptibility reveals an extra zero mode for low doping and strong coupling values signaling an intrinsic instability of the homogeneous spiral state. In addition, near-zero modes are found in the vicinity of the spiral pitch wave number for out-of-plane spin fluctuations. Their origin is found to be the near degeneracy with staggered noncoplanar spiral states which, however, are not the lowest energy Hartree-Fock solutions among the homogeneous spiral states. copyright 1996 The American Physical Society

  20. Analisa Kekuatan Spiral Bevel Gear Dengan Variasi Sudut Spiral Menggunakan Metode Elemen Hingga

    OpenAIRE

    Deta Rachmat Andika; Agus Sigit Pramono

    2017-01-01

    Seiring perkembangan zaman,  teknologi roda gigi dituntut untuk mampu mentransmisikan daya yang besar dengan efisiensi yang besar pula. Pada jenis intersecting shaft gear, tipe roda gigi payung spiral (spiral bevel gear)  merupakan perkembangan dari roda gigi payung bergigi lurus (straight bevel gear). Kelebihan dari spiral bevel gear antara  lain adalah kemampuan transmisi daya dan efisiensi yang lebih besar pada geometri yang sama serta tidak terlalu berisik. Akan tetapi spiral bevel gear j...

  1. Solvable model of spiral wave chimeras.

    Science.gov (United States)

    Martens, Erik A; Laing, Carlo R; Strogatz, Steven H

    2010-01-29

    Spiral waves are ubiquitous in two-dimensional systems of chemical or biological oscillators coupled locally by diffusion. At the center of such spirals is a phase singularity, a topological defect where the oscillator amplitude drops to zero. But if the coupling is nonlocal, a new kind of spiral can occur, with a circular core consisting of desynchronized oscillators running at full amplitude. Here, we provide the first analytical description of such a spiral wave chimera and use perturbation theory to calculate its rotation speed and the size of its incoherent core.

  2. Evolutionary Acquisition and Spiral Development Tutorial

    National Research Council Canada - National Science Library

    Hantos, P

    2005-01-01

    .... NSS Acquisition Policy 03-01 provided some space-oriented customization and, similarly to the original DOD directives, also positioned Evolutionary Acquisition and Spiral Development as preferred...

  3. Solvable Model of Spiral Wave Chimeras

    DEFF Research Database (Denmark)

    Martens, Erik Andreas; Laing, Carlo R.; Strogatz, Steven H.

    2010-01-01

    Spiral waves are ubiquitous in two-dimensional systems of chemical or biological oscillators coupled locally by diffusion. At the center of such spirals is a phase singularity, a topological defect where the oscillator amplitude drops to zero. But if the coupling is nonlocal, a new kind of spiral...... can occur, with a circular core consisting of desynchronized oscillators running at full amplitude. Here, we provide the first analytical description of such a spiral wave chimera and use perturbation theory to calculate its rotation speed and the size of its incoherent core....

  4. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    International Nuclear Information System (INIS)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H.

    2009-01-01

    coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

  5. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

    Science.gov (United States)

    Flohr, Thomas G; Leng, Shuai; Yu, Lifeng; Aiimendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H

    2009-12-01

    acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). A high-pitch (up to pitch = 3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch = 1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

  6. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H. [Siemens Healthcare, Computed Tomography, 91301 Forchheim, Germany and Department of Diagnostic Radiology, Eberhard-Karls-Universitaet, 72076 Tuebingen (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Siemens Healthcare, Computed Tomography, 91301 Forchheim (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2009-12-15

    coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

  7. Spiral 2 the scientific objectives

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-06-15

    The French ministry of research took the decision to build Spiral-2 in May 2005. Its construction costs are estimated to 130 million euros while its operating costs will near 8.5 million euros per year. The construction works will last 5 years. The Spiral-2 facility is based on a high power, superconducting driver Linac, which will deliver a high intensity, 40 MeV deuteron beam as well as a variety of heavy-ion beams with mass over charge ratio equal to 3 and energy up to 14.5 MeV/nucleon. Using a carbon converter, fast neutrons from the breakup of the 5 mA of deuterons impinging on a uranium carbide target will induce a rate of up to 10{sup 14} fissions/s. The radioactive ion beam intensities in the mass range from A = 60 to 140 will be of the order of 10{sup 6} to 10{sup 11} particles/s surpassing by one or two orders-of-magnitude any existing facility in the world. A direct irradiation of the UC{sub 2} target with {sup 3,4}He, {sup 6,7}Li or {sup 12}C may also be used. Different production targets will be used to produce high-intensity beams of light radioactive species with the Isol technique. The extracted radioactive ion beam will be accelerated to energies up to 20 MeV/nucleons by the existing Cime cyclotron. One of the most important features of the future Ganil accelerator complex will be the capability of delivering up to 5 stable or radioactive beams simultaneously in the energy range from the keV to several tens of MeV/nucleons. The document details also the future contribution of Spiral-2 concerning the structure of exotic nuclei, the thermodynamical aspects of nuclear matter, nucleosynthesis, the fundamental basic interactions, and the use of neutrons. (A.C.)

  8. Spiral 2 the scientific objectives

    International Nuclear Information System (INIS)

    2006-06-01

    The French ministry of research took the decision to build Spiral-2 in May 2005. Its construction costs are estimated to 130 million euros while its operating costs will near 8.5 million euros per year. The construction works will last 5 years. The Spiral-2 facility is based on a high power, superconducting driver Linac, which will deliver a high intensity, 40 MeV deuteron beam as well as a variety of heavy-ion beams with mass over charge ratio equal to 3 and energy up to 14.5 MeV/nucleon. Using a carbon converter, fast neutrons from the breakup of the 5 mA of deuterons impinging on a uranium carbide target will induce a rate of up to 10 14 fissions/s. The radioactive ion beam intensities in the mass range from A = 60 to 140 will be of the order of 10 6 to 10 11 particles/s surpassing by one or two orders-of-magnitude any existing facility in the world. A direct irradiation of the UC 2 target with 3,4 He, 6,7 Li or 12 C may also be used. Different production targets will be used to produce high-intensity beams of light radioactive species with the Isol technique. The extracted radioactive ion beam will be accelerated to energies up to 20 MeV/nucleons by the existing Cime cyclotron. One of the most important features of the future Ganil accelerator complex will be the capability of delivering up to 5 stable or radioactive beams simultaneously in the energy range from the keV to several tens of MeV/nucleons. The document details also the future contribution of Spiral-2 concerning the structure of exotic nuclei, the thermodynamical aspects of nuclear matter, nucleosynthesis, the fundamental basic interactions, and the use of neutrons. (A.C.)

  9. The rotation of spiral galaxies.

    Science.gov (United States)

    Rubin, V C

    1983-06-24

    There is accumulating evidence that as much as 90 percent of the mass of the universe is nonluminous and is clumped, halo-like, around individual galaxies. The gravitational force of this dark matter is presumed to be responsible for the high rotational velocities of stars and gas in the disks of spiral galaxie. At present, the form of the dark matter is unknown. Possible candidates span a range in mass of 10(70), from non-zero-mass neutrinos to massive black holes.

  10. Clinical application of three-dimensional imaging with multislice CT for laparoscopic colorectal surgery

    International Nuclear Information System (INIS)

    Matsuki, Mitsuru; Okuda, Jyunji; Yoshikawa, Syushi

    2003-01-01

    Laparoscopic colorectal surgery, while minimally invasive, is a complicated technique. Therefore, prior to this surgery, it is important to determine the anatomical information of colorectal cancer. Fifty-eight cases of patients with a confirmed diagnosis of colon cancer [caecal (n=4), ascending colon (n=6), transverse colon (n=7), descending colon (n=2), sigmoid colon (n=22), and rectal (n=17) cancer] were evaluated using multislice CT before laparoscopic surgery. CT examination was performed in an air-filled colorectum by colon fiberscopy. Contrast-enhanced images on multislice CT were obtained at arterial and venous phases. All images were reviewed on a workstation, and three-dimensional (3D) images of vessels, colorectum, cancer, and swollen lymph nodes were reconstructed by volume rendering and fused (integrated 3D imaging). We evaluated the usefulness of integrated 3D imaging with multislice CT for laparoscopic colorectal surgery. Integrated 3D imaging demonstrated clearly the distribution of arteries feeding the colorectal cancer and the anatomical location of colorectal cancer and arterial and venous systems. Moreover, measurement of the distance between the aortic bifurcation and the origin of the inferior mesenteric artery and that between the base of the inferior mesenteric artery and the origin of the left colic artery on integrated 3D imaging contributed to safe, prompt ligation of the vessels and excision of lymph nodes. Integrated 3D imaging with multislice CT was useful for simulation of laparoscopic colorectal surgery. (author)

  11. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  12. Clinical application of three-dimensional imaging with multislice CT for laparoscopic colorectal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Matsuki, Mitsuru; Okuda, Jyunji; Yoshikawa, Syushi [Osaka Medical Coll., Takatsuki (Japan)] (and others)

    2003-03-01

    Laparoscopic colorectal surgery, while minimally invasive, is a complicated technique. Therefore, prior to this surgery, it is important to determine the anatomical information of colorectal cancer. Fifty-eight cases of patients with a confirmed diagnosis of colon cancer [caecal (n=4), ascending colon (n=6), transverse colon (n=7), descending colon (n=2), sigmoid colon (n=22), and rectal (n=17) cancer] were evaluated using multislice CT before laparoscopic surgery. CT examination was performed in an air-filled colorectum by colon fiberscopy. Contrast-enhanced images on multislice CT were obtained at arterial and venous phases. All images were reviewed on a workstation, and three-dimensional (3D) images of vessels, colorectum, cancer, and swollen lymph nodes were reconstructed by volume rendering and fused (integrated 3D imaging). We evaluated the usefulness of integrated 3D imaging with multislice CT for laparoscopic colorectal surgery. Integrated 3D imaging demonstrated clearly the distribution of arteries feeding the colorectal cancer and the anatomical location of colorectal cancer and arterial and venous systems. Moreover, measurement of the distance between the aortic bifurcation and the origin of the inferior mesenteric artery and that between the base of the inferior mesenteric artery and the origin of the left colic artery on integrated 3D imaging contributed to safe, prompt ligation of the vessels and excision of lymph nodes. Integrated 3D imaging with multislice CT was useful for simulation of laparoscopic colorectal surgery. (author)

  13. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  14. Spiral density waves in M81. I. Stellar spiral density waves

    International Nuclear Information System (INIS)

    Feng, Chien-Chang; Lin, Lien-Hsuan; Wang, Hsiang-Hsu; Taam, Ronald E.

    2014-01-01

    Aside from the grand-design stellar spirals appearing in the disk of M81, a pair of stellar spiral arms situated well inside the bright bulge of M81 has been recently discovered by Kendall et al. The seemingly unrelated pairs of spirals pose a challenge to the theory of spiral density waves. To address this problem, we have constructed a three-component model for M81, including the contributions from a stellar disk, a bulge, and a dark matter halo subject to observational constraints. Given this basic state for M81, a modal approach is applied to search for the discrete unstable spiral modes that may provide an understanding for the existence of both spiral arms. It is found that the apparently separated inner and outer spirals can be interpreted as a single trailing spiral mode. In particular, these spirals share the same pattern speed 25.5 km s –1 kpc –1 with a corotation radius of 9.03 kpc. In addition to the good agreement between the calculated and the observed spiral pattern, the variation of the spiral amplitude can also be naturally reproduced.

  15. QS Spiral: Visualizing Periodic Quantified Self Data

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Cuttone, Andrea; Jørgensen, Sune Lehmann

    2013-01-01

    In this paper we propose an interactive visualization technique QS Spiral that aims to capture the periodic properties of quantified self data and let the user explore those recurring patterns. The approach is based on time-series data visualized as a spiral structure. The interactivity includes ...

  16. Spiral modes in cold cylindrical systems

    International Nuclear Information System (INIS)

    Robe, H.

    1975-01-01

    The linearized hydrodynamical equations governing the non-axisymmetric free modes of oscillation of cold cylindrical stellar systems are separated in cylindrical coordinates and solved numerically for two models. Short-wavelength unstable modes corresponding to tight spirals do not exist; but there exists an unstable growing mode which has the form of trailing spirals which are quite open. (orig.) [de

  17. Spiral groove seal. [for rotating shaft

    Science.gov (United States)

    Ludwig, L. P.; Strom, T. N. (Inventor)

    1974-01-01

    Mating flat surfaces inhibit leakage of a fluid around a stationary shaft. A spiral groove produces a pumping action toward the fluid when the shaft rotates. This prevents leakage while a generated hydraulic lifting force separates the mating surfaces to minimize wear. Provision is made for placing these spiral grooves in communication with the fluid to accelerate the generation of the hydraulic lifting force.

  18. ANGULAR-MOMENTUM IN BINARY SPIRAL GALAXIES

    NARCIS (Netherlands)

    OOSTERLOO, T

    In order to investigate the relative orientations of spiral galaxies in pairs, the distribution of the angle between the spin-vectors for a new sample of 40 binary spiral galaxies is determined. From this distribution it is found, contrary to an earlier result obtained by Helou (1984), that there is

  19. Colours and morphology of spiral galaxies

    International Nuclear Information System (INIS)

    Wyse, R.F.G.

    1981-01-01

    Tinsley has proposed that late-type spirals have relatively more non-luminous material than early-type spirals. A re-examination of the data indicates that this proposal is equally consistent with dark matter being more dominant in barred galaxies than in unbarred galaxies. Neither conclusion can be firm, since the dataset is far from ideal. (author)

  20. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  1. Improved reconstruction for IDEAL spiral CSI

    DEFF Research Database (Denmark)

    Hansen, Rie Beck; Mariager, Christian; Laustsen, Christoffer

    2017-01-01

    In this study we demonstrate how reconstruction for IDEAL spiral CSI (spectroscopic imaging scheme developed for hyperpolarized dynamic metabolic MR imaging) can be improved by using regularization with a sparsity constraint. By exploiting sparsity of the spectral domain, IDEAL spiral CSI can...

  2. Mass of the spirals galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Maupome, L; Pismis, P; Aguilar, L [Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Astronomia

    1981-01-01

    In an earlier paper we have found that the total mass of galaxies-especially of the spirals-based on values published until 1975, decreased as the Hubble type varied from Sa through Sc and Irregulars. It was also pointed out that masses determined from the hydrogen 21-cm line were higher than the optically determined masses. To investigate the cause of these tendencies we have estimated the masses using an analytic rotation curve of Brandt adjusted to the optical observations in order to include all the mass of a galaxy up to the last observed point. Although the masses computed in this manner were found to be larger, as expected, the decrease of mass with Hubble type found earlier is confirmed. However, there is a discrepancy in the earlier types (Sa, Sab) in that their radio-masses are smaller than the optically determined ones. At present, the cause of this is not clear.

  3. Multi-slice CT urography after diuretic injection: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Wildberger, J.E.; Schmitz-Rode, T.; Guenther, R.W. [Technische Univ. Aachen (Germany). Dept. of Diagnostic Radiology; Borchers, H. [Technische Univ. Aachen (Germany). Dept. of Urology

    2001-03-01

    Purpose: To investigate the feasibility of CT urography (CTU) using a multi-slice (MS) scanner and to find out whether a low-dose diuretic injection is advantageous for the opacification of the urinary tract. Methods: MS-CTU was performed in 21 patients with urologic diseases. In 5/21 patients, 250 ml of physiologic saline solution were injected. In 16/21 patients, 10 mg of furosemide were injected 3-5 min before contrast material administration. A 4x2.5 mm collimation with a pitch of 1.25 and a tube curent of 100-150 mA were used. Scan time was 12-16 sec. 3 mm thin axial images with an overlap of 67% were reconstructed. Multiplanar maximum intensity projection (MIP) images were postprocessed to obtain urographic views. Bone structures were eliminated using the volume-of-interest method. Results: Furosemide-enhanced MS-CTU achieved either near complete or complete opacification in 30/32 (94%) ureters and in 32/32 (100%) pelvicaliceal systems up to a serum creatinine of 150 {mu}mol/l. In our series, only one CTU scan per patient was needed to obtain a diagnostic urogram after 10 min of contrast material injection. Ureteral compression was not necessary. When physiologic saline solution was used instead of furosemide, the radiopacity inside the enhanced pelvicalices was 4-5 times higher and more inhomogeneous. Diuretic-enhanced MS-CTU was more accurate in the depiction of pelvicaliceal details. In combination with furosemide, calculi were well identified inside the opacified urine and were safely differentiated from phleboliths. Postprocessing times of up to 20 minutes were problematic as were contrast-enhanced superimposing bowel loops on MIP images. Conclusion: Preliminary results demonstrate a good feasibility of furosemide-enhanced MS-CTU for obtaining detailed visualization of the entire upper urinary tract. (orig.) [German] Ziel: Untersuchung zur Durchfuehrbarkeit der CT Urographie (CTU) mit einem Multidetektor(MD)-Computertomographen und ob eine

  4. Imaging anatomy of the infraorbital ethmoid cells on multislice CT

    International Nuclear Information System (INIS)

    Pan Zhenyu; Qian Xiaojun; Gu Hua; Zhai Renyou

    2008-01-01

    Objective: To study the anatomic characteristics of the infraorbital ethmoid cells on multislice CT (MSCT) and explore the relationship between the infraobital ethmoid cells and mucosal swelling of sinuses. Methods: Two hundred sixty patients (520 sides) of consecutive axial scans by GE Hispeed VCT and the multiplanar reformation (MPR), virtual endoscopy(VE) reconstruction images by GE AW 4.2 workstation were reviewed retrospectively. The following CT features were assessed: (1) the anatomic characteristics of the infraobital ethmoid cells, including the frequency of identification, origin, classification, (2) presence of mucosal swelling of sinuses, (3) the maximal transversal diameter of the infraobital ethmoid cells in ostium of maxillary sinus (perpendicular to the uncinate process), and the diameter of the ostium of maxillary sinus, (4) presence of infraobital ethmoid cells inflammatory findings and a contact between the mucosal surface of the ostium of maxillary sinus. The results were analyzed by using Chi-square test and logistic regression analysis with the statistical software SPSS 11.5. Results: (1) Unilateral infraobital ethmoid cells were found in 68 patients (26.1%), and bilateral infraobital ethmoid cells were found in 81 patients (31.2%). Infraobital ethmoid cells were found in 230 sides on left side (120 sides) and right side(110 sides). (2)Infraobital ethmoid cells originated from the anterior ethmoid cells in 124 sides (53.9%) and from posterior ethmoidal cells in 62 sides (27%), originated from both the anterior ethmoidal cells and the posterior ethmoidal cells in 44 sides( 19. 1% ). (3)The classification of the infraobital ethmoid cells included three types. Infraobital ethmoid cells with different origination differed significantly in their types (X 2 =193.433, P 2 =1.824, P>0.05). The maximal transversal diameter of the infraobital ethmoid cells in ostium of maxillary sinus did not differ significantly between the cases with or without

  5. IMRT delivery verification using a spiral phantom

    International Nuclear Information System (INIS)

    Richardson, Susan L.; Tome, Wolfgang A.; Orton, Nigel P.; McNutt, Todd R.; Paliwal, Bhudatt R.

    2003-01-01

    In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan

  6. Measuring of the airway dimensions with spiral CT images: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huibin; Ma Ji; Wu Gang; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To measure the length, angle and their correlation of the main anatomical dimensions of the trachea and bronchus in experimental Japanese white big-ear rabbits with the help of spiral CT 3D images, in order to lay the foundation of treating the airway disorders with stenting in animal experiment. Methods: Multi-slice CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the longitudinal, transversal dimensions of the trachea, the glottis-carina length, the inner diameter and length of bronchi, and the angle formed by bronchial long axis and sagittal section were measured. Results: No significant difference was found in the inner diameters of various parts of the trachea and upper apical bronchi. The angle formed by bronchial long axis and sagittal section were smaller than that of the left ones. And the inner diameters of the right main bronchus was bigger than the left ones. Conclusion: The complex branching structure of the rabbit airway tree can be well displayed on spiral CT 3D images. Through measuring and statistical analysis of the results the authors have got a regressive equation for estimating the value of the inner diameter, length, angle, etc. concerning the airway tree, which is very helpful for providing the useful anatomical parameters in rabbit experiment. (authors)

  7. Right Ventricular Ejection Fraction using ECG-Gated First Pass Cardioangiography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Young Hee; Lee, Hae Giu; Lee, Sung Yong; Park, Suk Min; Chung, Soo Kyo; Yim, Jeong Ik; Bahk, Yong Whee; Shinn, Kyung Sub; Kim, Young Gyun; Kwon, Soon Seog [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1993-03-15

    Radionuclide cardioangiography has been widely applied and has played major roles in moninvasive assessment of cardiac function. Three techniques, first-pass gated first and gated equilibrium methods have commonly been used to evaluate right ventricular ejection fraction which usually abnormal in the patients with cardiopulmonary disease. It has been known that the gated first pass method is most accurate method among the three techniques in assessment of fight ventricular ejection fraction. The radionuclide right ventricular ejection fraction values were determined in 13 normal subjects and in 15 patients with chronic obstructive pulmonary disease by the gated first pass method and compared with those of the first pass method because there has been no published data of fight ejection fraction by the gated first pass method were compared with the defects from the pulmonary function test performed in the patients with chronic obstructive pulmomary disease. The results were as follows; 1) The values of fight ventricular ejection fraction by the gated first pass method were 50.1 +- 6.1% in normal subjects and 38.5 +- 8.5 in the patients with chronic obstructive pulmonary disease. There was statistically significant difference between the right ventricular ejection fraction of each of the two groups (p<0.05) 2) The right ventricular ejection fraction by the gated first pass method was not linearly correlated ith FEV{sub 1}, VC. DLCO. and FVC as well as P{sub a}O2 and P{sub a}CO2 of the patients with chronic obstructive pulmonary disease. We concluded that right ventricular ejection fraction by the gated first pass method using radionuclide cardioangiography may be useful in clinical assessment of the right ventricular function.

  8. Reproducibility of ECG-gated Ultrasound Diameter Assessment of Small Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Bredahl, K; Eldrup, N; Meyer, C

    2013-01-01

    No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation....

  9. Limited value of interlaced ECG-gated radiography in the presence of a normal chest radiograph

    International Nuclear Information System (INIS)

    Chen, J.T.T.; Ravin, C.E.; Handel, D.

    1984-01-01

    Twenty-seven patients with normal posteroanterior and lateral chest radiographs, who were undergoing cardiac catheterization because of symptoms strongly suggesting coronary artery disease, also had posteroanterior and lateral interlaced electrocardiogram-gated radiographs made. In 14 patients, the interlaced radiography system underestimated (suggested hypokinesia) the wall motion, which was normal on cardiac catheterization. In two cases the system overestimated the wall motion, in two others it both under- and overestimated the motion, and in only nine cases was the correlation correct. These data suggest that the technique is of limited application, particularly in cases in which the routine chest radiographs are normal

  10. Evaluation of regional wall motion in myocardial infarction using animation ECG gated cardiac computed tomography

    International Nuclear Information System (INIS)

    Shimizu, Takahiko; Hyodo, Haruo; Hayashi, Terumi; Yamamoto, Hideo; Yagi, Shigeru

    1984-01-01

    Regional wall motion of the left ventricle was evaluated in 21 patients with myocardial infarction using an animation system of gated cardiac computed tomographic (CT) images (animation gated CCT). The results obtained were compared with data by two-dimensional echocardiography (2-DE). 1. Evaluation of the asynergic area by animation gated CCT and 2-DE: Animation gated CCT detected the following specific regions with asynergy established by 2-DE; 10/10 cases (100%) at the anterior wall of the left ventricle, 14/14 cases (100%) at the interventricular septum, and 9/11 cases (81.8%) at the infero-posterior wall. In addition, one false positive case and one negative case were observed at the lateral wall and the apex, respectively. Of 37 instances with asynergic areas established by 2-DE, 21 cases or 89.2% were detected by animation gated CCT; the sensitivity was 91.9%. 2. Evaluation of severity of asynergy by animation gated CCT and 2-DE: The degree of asynergy evaluated by both methods was compared with each other, and the agreement was as follows: 10/10 cases (100%) at the left-ventricular anterior wall, 13/13 cases (100%) at the interventricular septum, and 7/9 cases (77.8%) at the infero-posterior wall. 3. Evaluation of the asynergic area by nonanimation gated CCT and 2-DE: Nonanimation gated CCT detected asynergic areas ascertained by 2-DE at the following areas; 8/10 cases (80%) at the left-ventricular anterior wall, 12/14 cases (85.7%) at the interventricular septum, and 4/11 cases (36.4%) at the infero-posterior wall. The difference between animation and nonanimation gated CCT was statistically significant (p<0.05). The severity of asynergy could not be evaluated by nonanimation gated CCT. (J.P.N.)

  11. Real-time QRS detection using integrated variance for ECG gated cardiac MRI

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2016-09-01

    Full Text Available During magnetic resonance imaging (MRI, a patient’s vital signs are required for different purposes. In cardiac MRI (CMR, an electrocardiogram (ECG of the patient is required for triggering the image acquisition process. However, a reliable QRS detection of an ECG signal acquired inside an MRI scanner is a challenging task due to the magnetohydrodynamic (MHD effect which interferes with the ECG. The aim of this work was to develop a reliable QRS detector usable inside the MRI which also fulfills the standards for medical devices (IEC 60601-2-27. Therefore, a novel real-time QRS detector based on integrated variance measurements is presented. The algorithm was trained on ANSI/AAMI EC13 test waveforms and was then applied to two databases with 12-lead ECG signals recorded inside and outside an MRI scanner. Reliable results for both databases were achieved for the ECG signals recorded inside (DBMRI: sensitivity Se = 99.94%, positive predictive value +P = 99.84% and outside (DBInCarT: Se = 99.29%, +P = 99.72% the MRI. Due to the accurate R-peak detection in real-time this can be used for monitoring and triggering in MRI exams.

  12. ECG-gated myocardial tomo-scintigraphy by rotating bilateral collimator. Clinical application and artificial defect

    Energy Technology Data Exchange (ETDEWEB)

    Komatani, Akio; Takahashi, Kazuei; Takanashi, Toshiyasu; Yamaguchi, Koichi [Yamagata Univ. (Japan)

    1985-01-01

    Tomo-scintigraphy of /sup 201/Tl-myocardium by rotating bilateral collimator was performed in synchronization with cardiac cycle. Ten frames per R-R interval were acquired with ECG pulse signal during 16 min and tomographic reconstruction of end-diastolic and end-systolic image was done. This method was very useful to estimate not only three dimensional distribution of Tl-201, but also wall motion and change of wall thickness during cardiac cycle. However, through its clinical application, artificial defect was frequently noticed at inferior-apical portion of the myocardium. In order to elucidate the cause of the artifact, influence of tilted projection and cardiac motion due to respiratory was also investigated. During inspiratory phase of patients in rest, increment of volume up to 40% and 15 mm of caudal deviation of the left ventricle were observed. Furthermore, periodic motion of the diaphragm interrupted emission of gamma ray from the myocardium. It is proved that main cause of the artifact was not tilting projection, but these influence of respiratory motion.

  13. The selection of window width and levels for measuring the airway dimensions with spiral CT scan: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huuibing; Wu Gang; Ma Ji; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To investigate the optimal window width and window level for measuring the airway dimensions with spiral CT scan in Japanese white big-ear rabbits so as to lay the foundation for airway stenting in animal experiments. Methods: Multi-slice spiral CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the anteroposterior and transversal diameter of the thoracic trachea, the anteroposterior diameter of the right and left bronchus were measured with lung window, mediastinum window and special fat window separately. The revealing rate of the tracheal wall and the measuring results in different windows and levels were recorded and compared with the anatomical data. The differences of the relevant data were statistically analyzed. Results: With lung window, the tracheal wall was well demonstrated, but the relevant data were smaller than that with mediastinum window. With mediastinum window, the data were bigger and the tracheal wall border appeared blurred. The results obtained with fat window were close to the actual anatomical data. Conclusion: For accurately measuring the anteroposterior and transversal diameter of the thoracic trachea in Japanese white big-ear rabbits with multi- slice spiral CT scan, fat window should be adopted, which is helpful for the preparation of tracheal and bronchial stents. (authors)

  14. 64 multislice computed tomography imaging of coronary artery origin anomalies in adults

    International Nuclear Information System (INIS)

    Dai Qinyi; Lv Biao; Zhang Zhaoqi

    2006-01-01

    Objective: To assess the value of 64 multislice computed tomography (64 MSCT) in the evaluation of coronary artery origin anomalies in adults. Methods: Nine hundred and seventy eight Chinese adult patients undergone coronary artery CT angiography (CTA) between March and July 2005 at Anzhen hospital were reviewed for this study. Results: In consecutive 978 patients, 64 MSCT identified (3.07%) with an anomalous origin of the coronary artery, in 30 patients including anomalous origin of the right coronary artery (RCA) in 9 patients, the left coronary artery (LCA)in 7 patients, both RCA and LCA in 2 patients, the absence of the left circumflex artery (LCX) in 1 patient and anomalous origin of the branch of coronary artery in 11 patients. Conclusion: Noninvasive 64 multislice computed tomography can detect the anomalous origin of the coronary artery with high resolution. (authors)

  15. Echo-Interleaved-Spiral MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, Shirrie; Azhari, Haim [Department of Biomedical Engineering, Technion, Israel Institute of Technology, Haifa 32000 (Israel); Montag, Avram [Elscint Ltd., MRI division, Haifa (Israel)

    1999-12-31

    Interleaved-Spiral imaging is an efficient method for MRI fast scans. However, images suffer from blurring and artifacts due to field inhomogeneities and the long readout times. In this paper, we combine interleaved-spirals with spin-echo for 3D scans. The refocusing RF-pulses (echoes) refocus off-resonance spins, thus allowing longer acquisition times per excitation, by limiting inhomogeneity effects. The total number of excitations for a 3D scan is reduced by half. The 3D Fourier transform of an object is divided into pairs of slices, one slice is scanned in an outgoing interleaved-spiral, initiated after a 90 degree pulse has been applied. The second slice is scanned in an ingoing interleaved-spiral, after a 180 degree pulse has been applied, thus reaching the slice origin at the echo time. (authors) 4 refs., 3 figs.

  16. Echo-Interleaved-Spiral MR Imaging

    International Nuclear Information System (INIS)

    Rosenthal, Shirrie; Azhari, Haim; Montag, Avram

    1998-01-01

    Interleaved-Spiral imaging is an efficient method for MRI fast scans. However, images suffer from blurring and artifacts due to field inhomogeneities and the long readout times. In this paper, we combine interleaved-spirals with spin-echo for 3D scans. The refocusing RF-pulses (echoes) refocus off-resonance spins, thus allowing longer acquisition times per excitation, by limiting inhomogeneity effects. The total number of excitations for a 3D scan is reduced by half. The 3D Fourier transform of an object is divided into pairs of slices, one slice is scanned in an outgoing interleaved-spiral, initiated after a 90 degree pulse has been applied. The second slice is scanned in an ingoing interleaved-spiral, after a 180 degree pulse has been applied, thus reaching the slice origin at the echo time. (authors)

  17. Corrosion of Spiral Rib Aluminized Pipe : [Summary

    Science.gov (United States)

    2012-01-01

    Large diameter, corrugated steel pipes are a common sight in the culverts that run alongside many Florida roads. Spiral-ribbed aluminized pipe (SRAP) has been widely specified by the Florida Department of Transportation (FDOT) for runoff drainage. Th...

  18. Corrosion of Spiral Rib Aluminized Pipe

    Science.gov (United States)

    2012-08-01

    Large diameter, corrugated steel pipes are a common sight in the culverts that run alongside many Florida roads. Spiral-ribbed aluminized pipe (SRAP) has been widely specified by the Florida Department of Transportation (FDOT) for runoff drainage. Th...

  19. Pulsatile spiral blood flow through arterial stenosis.

    Science.gov (United States)

    Linge, Fabian; Hye, Md Abdul; Paul, Manosh C

    2014-11-01

    Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.

  20. Magnetic spiral arms in galaxy haloes

    Science.gov (United States)

    Henriksen, R. N.

    2017-08-01

    We seek the conditions for a steady mean field galactic dynamo. The parameter set is reduced to those appearing in the α2 and α/ω dynamo, namely velocity amplitudes, and the ratio of sub-scale helicity to diffusivity. The parameters can be allowed to vary on conical spirals. We analyse the mean field dynamo equations in terms of scale invariant logarithmic spiral modes and special exact solutions. Compatible scale invariant gravitational spiral arms are introduced and illustrated in an appendix, but the detailed dynamical interaction with the magnetic field is left for another work. As a result of planar magnetic spirals `lifting' into the halo, multiple sign changes in average rotation measures forming a regular pattern on each side of the galactic minor axis, are predicted. Such changes have recently been detected in the Continuum Halos in Nearby Galaxies-an EVLA Survey (CHANG-ES) survey.

  1. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee

    2009-01-01

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  2. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea); Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun [University of Ulsan College of Medicine, Department of Pediatric Cardiac Surgery, Asan Medical Center, Seoul (Korea); Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee [University of Ulsan College of Medicine, Department of Pediatric Cardiology, Asan Medical Center, Seoul (Korea)

    2009-03-15

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  3. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    OpenAIRE

    Sidipratomo, Prijo; Prija, Trijono Karmawan Sukana; Murtala, Bachtiar; Purwadianto, Agus; Lawrence, Gatot Susilo

    2014-01-01

    BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT) scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic M...

  4. Diagnosis of temporal bone diseases using three-dimensional images with multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Yoshihiro; Togami, Taro; Murota, Makiko; Fukunaga, Kotaro; Hino, Ichiro; Sato, Katashi; Ohkawa, Motoomi [Kagawa Medical Univ., Miki (Japan)

    2001-08-01

    We evaluated the usefulness of three-dimensional images with multislice CT in the temporal bone diseases. Fifty-nine cases (26 with medial otitis, 8 choresteatoma, 10 congenital malformation, 3 high jugular bulb, 2 otosclerosis, and 10 others) were included in this study. In the ossicular and inner ear lesions, oblique multiplanar images of the long axis of each ossicle was useful the detection of abnormality. Structural deformity of ossicles and bony labyrinth were clearly delineated by surface rendering images. (author)

  5. Anatomical variations of paranasal sinuses at multislice computed tomography: what to look for

    International Nuclear Information System (INIS)

    Miranda, Christiana Maia Nobre Rocha de; Maranhao, Carol Pontes de Miranda; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Jatoba, Mayara Stephanie de Araujo; Andrade, Anna Carolina Mendonca de; Padilha, Bruno Gomes

    2011-01-01

    Multislice computed tomography is currently the imaging modality of choice for evaluating paranasal sinuses and adjacent structures. Such a method has been increasingly utilized in the assessment of anatomical variations, allowing their accurate identification with high anatomical details. Some anatomical variations may predispose to sinusal diseases, constituting areas of high risk for injuries and complications during surgical procedures. Therefore, the recognition of such variations is critical in the preoperative evaluation for endoscopic surgery. (author)

  6. Anatomical variations of paranasal sinuses at multislice computed tomography: what to look for

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Christiana Maia Nobre Rocha de; Maranhao, Carol Pontes de Miranda [Clinica de Medicina Nuclear e Radiologia de Maceio (Medradius), Maceio, AL (Brazil). Setor de Tomografia Computadorizada; Arraes, Fabiana Maia Nobre Rocha [Clinica Sinus, Maceio, AL (Brazil); Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Jatoba, Mayara Stephanie de Araujo; Andrade, Anna Carolina Mendonca de; Padilha, Bruno Gomes [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil)

    2011-07-15

    Multislice computed tomography is currently the imaging modality of choice for evaluating paranasal sinuses and adjacent structures. Such a method has been increasingly utilized in the assessment of anatomical variations, allowing their accurate identification with high anatomical details. Some anatomical variations may predispose to sinusal diseases, constituting areas of high risk for injuries and complications during surgical procedures. Therefore, the recognition of such variations is critical in the preoperative evaluation for endoscopic surgery. (author)

  7. Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min; Sun, Ai-Min; Wang, Qian; Zhu, Ming; Qiu, Hai-Sheng [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Radiology, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Liu, Jin-Fen [Shanghai Children' s Medical Center, Department of Cardiothoracic Surgery, Shanghai (China); Gao, Wei [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Cardiology, Shanghai (China); Berdon, Walter E. [Children' s Hospital of New York, Department of Radiology, New York, NY (United States)

    2014-07-15

    Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon. (orig.)

  8. Morphological and functional diagnosis in the head and neck with multiplanar spiral CT

    International Nuclear Information System (INIS)

    Lell, M.; Baum, U.; Noemayr, A.; Greess, H.; Lenz, M.; Bautz, W.; Koester, M.

    1999-01-01

    Purpose: To evaluate the improvement of multislice-spiral CT in the assessment of head and neck tumors. Material and methods: 80 patients with suspected tumor in the head and neck region were examined with MSCT (Somatom Plus 4 VZ) after the administration of i.v. contrast material. Slice collimation was 4x1 mm with a pitch factor of 6. Additional multiplanar reformations were calculated in each case. Results: The specific anatomy and pathways of tumor spread is difficult to demonstrate in cross-sectional imaging. Tumor infiltration of the base of the skull or the palate could be depicted or excluded on coronal MPR, additional coronal scanning was not necessary. The detection of pathologic lymph nodes was improved with MPR in 7 patients. Discussion: The exact determination of tumor margins is mandatory for modern therapy concepts of limited surgery. High resolution datasets are basis for reformations in arbitrary planes, making additional coronal scanning not necessary. Functional imaging of the larynx and hypopharynx improve the diagnostic accuracy of CT, a short scantime is necessary to reduce motion artifacts. Conclusive assessment of tumor infiltration, lymphatic spread and functional alterations is improved with MSCT. (orig.) [de

  9. Statistical analysis of metallicity in spiral galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Galeotti, P [Consiglio Nazionale delle Ricerche, Turin (Italy). Lab. di Cosmo-Geofisica; Turin Univ. (Italy). Ist. di Fisica Generale)

    1981-04-01

    A principal component analysis of metallicity and other integral properties of 33 spiral galaxies is presented; the involved parameters are: morphological type, diameter, luminosity and metallicity. From the statistical analysis it is concluded that the sample has only two significant dimensions and additonal tests, involving different parameters, show similar results. Thus it seems that only type and luminosity are independent variables, being the other integral properties of spiral galaxies correlated with them.

  10. Galactic models with variable spiral structure

    International Nuclear Information System (INIS)

    James, R.A.; Sellwood, J.A.

    1978-01-01

    A series of three-dimensional computer simulations of disc galaxies has been run in which the self-consistent potential of the disc stars is supplemented by that arising from a small uniform Population II sphere. The models show variable spiral structure, which is more pronounced for thin discs. In addition, the thin discs form weak bars. In one case variable spiral structure associated with this bar has been seen. The relaxed discs are cool outside resonance regions. (author)

  11. Visualization of brain surface structures by weighted summation technique using multislice MR images

    International Nuclear Information System (INIS)

    Machida, Yoshio; Hatanaka, Masahiko; Hagiwara, Masayuki; Sugimoto, Hiroshi; Yoshida, Tadatoki; Katada, Kazuhiro.

    1991-01-01

    Surface anatomy scanning (SAS) technique which visualizes brain surface structures has been developed since 1987. In this paper, we propose a modified method called 'multislice SAS', which also generates such surface structure images, and has several advantages compared with conventional SAS technique. The conventional SAS technique uses a very long echo time sequence (e.g. SE(3000, 250)) with a thick slice and a surface coil to enhance CSF on the brain surface. Our modified technique also uses a long echo time sequence. But, added multislice images, each appropriately weighted, are used in stead of a thick slice and a surface coil. Our basic studies have shown that this modified method has the following advantage: Several surface images with slightly different summation directions are obtained, and they are used for stereographic display and cine display. This is very useful for visualizing the spatial relationship of brain surface structures. By choosing appropriate weighting, we can obtain clinically legible surface images. This technique dose not require a surface coil. It means that flexibility of selecting imaging direction is high. We can make a lot of modifications, because the original multislice images of weighted summation are arbitrary. And we also clarify some limitation or disadvantage of this modified method. In conclusion, we think that this technique is one of the practical approaches for surface anatomy imaging. (author)

  12. Role of Multislice Computed Tomography and Local Contrast in the Diagnosis and Characterization of Choanal Atresia

    Directory of Open Access Journals (Sweden)

    Khaled Al-Noury

    2011-01-01

    Full Text Available Objective. To illustrate the role of multislice computed tomography and local contrast instillation in the diagnosis and characterization of choanal atresia. To review the common associated radiological findings. Methods. We analyzed 9 pediatric patients (5 males and 4 females with suspected choanal atresia by multislice computed tomography. We recorded the type of atresia plate and other congenital malformations of the skull. Results. Multislice computed tomography with local contrast installed delineated the posterior choanae. Three patients had unilateral mixed membranous and bony atresia. Three patients had unilateral pure bony atresia. Only 1 of 7 patients have bilateral bony atresia. It also showed other congenital anomalies in the head region. One patient is with an ear abnormality. One patient had congenital nasal pyriform aperture stenosis. One of these patients had several congenital abnormalities, including cardiac and renal deformities and a hypoplastic lateral semicircular canal. Of the 6 patients diagnosed to have choanal atresia, 1 patient had esophageal atresia and a tracheoesophageal fistula. The remaining patients had no other CHARGE syndrome lesions. Conclusions. Local Contrast medium with the application of the low-dose technique helps to delineate the cause of the nasal obstruction avoiding a high radiation dose to the child.

  13. SIGNATURES OF LONG-LIVED SPIRAL PATTERNS

    International Nuclear Information System (INIS)

    Martínez-García, Eric E.; González-Lópezlira, Rosa A.

    2013-01-01

    Azimuthal age/color gradients across spiral arms are a signature of long-lived spirals. From a sample of 19 normal (or weakly barred) spirals where we have previously found azimuthal age/color gradient candidates, 13 objects were further selected if a two-armed grand-design pattern survived in a surface density stellar mass map. Mass maps were obtained from optical and near-infrared imaging, by comparison with a Monte Carlo library of stellar population synthesis models that allowed us to obtain the mass-to-light ratio in the J band, (M/L) J , as a function of (g – i) versus (i – J) color. The selected spirals were analyzed with Fourier methods in search of other signatures of long-lived modes related to the gradients, such as the gradient divergence toward corotation, and the behavior of the phase angle of the two-armed spiral in different wavebands, as expected from theory. The results show additional signatures of long-lived spirals in at least 50% of the objects.

  14. Chiralities of spiral waves and their transitions.

    Science.gov (United States)

    Pan, Jun-ting; Cai, Mei-chun; Li, Bing-wei; Zhang, Hong

    2013-06-01

    The chiralities of spiral waves usually refer to their rotation directions (the turning orientations of the spiral temporal movements as time elapses) and their curl directions (the winding orientations of the spiral spatial geometrical structures themselves). Traditionally, they are the same as each other. Namely, they are both clockwise or both counterclockwise. Moreover, the chiralities are determined by the topological charges of spiral waves, and thus they are conserved quantities. After the inwardly propagating spirals were experimentally observed, the relationship between the chiralities and the one between the chiralities and the topological charges are no longer preserved. The chiralities thus become more complex than ever before. As a result, there is now a desire to further study them. In this paper, the chiralities and their transition properties for all kinds of spiral waves are systemically studied in the framework of the complex Ginzburg-Landau equation, and the general relationships both between the chiralities and between the chiralities and the topological charges are obtained. The investigation of some other models, such as the FitzHugh-Nagumo model, the nonuniform Oregonator model, the modified standard model, etc., is also discussed for comparison.

  15. Spiral 2: preliminary design study

    International Nuclear Information System (INIS)

    2001-11-01

    The scientific council of GANIL asked to perform a comparative study on the production methods based on gamma induced fission and rapid-neutron induced fission concerning the nature and the intensity of the neutron-rich products. The production rate expected should be around 10 13 fissions per second. The study should include the implantation and the costs of the concerned accelerators. The scientific committee recommended also to study the possibility to re-inject the radioactive beams of SPIRAL-II in the cyclotrons available at GANIL in order to give access to an energy range from 1.7 to 100 MeV/nucleon. For that purpose, some study groups have been formed to evaluate the possibility of such a project in the different components: physics case, target-ion sources, drivers, post-acceleration and general infrastructure. The organization of the project study is given at the end of this report. The following report presents an overview of the study. Particularly the total costs have been assessed according to 3 options for the driver: 38.0*10 6 euros for a 40 MeV deuteron linac, 18.7*10 6 euros for a 45 MeV electron linac, and 29.1*10 6 euros for a 80 MeV deuteron cyclotron

  16. Spiral 2: preliminary design study

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-11-15

    The scientific council of GANIL asked to perform a comparative study on the production methods based on gamma induced fission and rapid-neutron induced fission concerning the nature and the intensity of the neutron-rich products. The production rate expected should be around 10{sup 13} fissions per second. The study should include the implantation and the costs of the concerned accelerators. The scientific committee recommended also to study the possibility to re-inject the radioactive beams of SPIRAL-II in the cyclotrons available at GANIL in order to give access to an energy range from 1.7 to 100 MeV/nucleon. For that purpose, some study groups have been formed to evaluate the possibility of such a project in the different components: physics case, target-ion sources, drivers, post-acceleration and general infrastructure. The organization of the project study is given at the end of this report. The following report presents an overview of the study. Particularly the total costs have been assessed according to 3 options for the driver: 38.0*10{sup 6} euros for a 40 MeV deuteron linac, 18.7*10{sup 6} euros for a 45 MeV electron linac, and 29.1*10{sup 6} euros for a 80 MeV deuteron cyclotron.

  17. Dark matter in spiral galaxies

    International Nuclear Information System (INIS)

    Albada, T.S. van; Sancisi, R.

    1986-01-01

    Mass models of spiral galaxies based on the observed light distribution, assuming constant M/L for bulge and disc, are able to reproduce the observed rotation curves in the inner regions, but fail to do so increasingly towards and beyond the edge of the visible material. The discrepancy in the outer region can be accounted for by invoking dark matter; some galaxies require at least four times as much dark matter as luminous matter. There is no evidence for a dependence on galaxy luminosity or morphological type. Various arguments support the idea that a distribution of visible matter with constant M/L is responsible for the circular velocity in the inner region, i.e. inside approximately 2.5 disc scalelengths. Luminous matter and dark matter seem to 'conspire' to produce the flat observed rotation curves in the outer region. It seems unlikely that this coupling between disc and halo results from the large-scale gravitational interaction between the two components. Attempts to determine the shape of dark halos have not yet produced convincing results. (author)

  18. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT

    International Nuclear Information System (INIS)

    Picozzi, Giulia; Paci, Enrico; Lopes Pegna, Andrea

    2005-01-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64±4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was [it

  19. Six Decades of Spiral Density Wave Theory

    Science.gov (United States)

    Shu, Frank H.

    2016-09-01

    The theory of spiral density waves had its origin approximately six decades ago in an attempt to reconcile the winding dilemma of material spiral arms in flattened disk galaxies. We begin with the earliest calculations of linear and nonlinear spiral density waves in disk galaxies, in which the hypothesis of quasi-stationary spiral structure (QSSS) plays a central role. The earliest success was the prediction of the nonlinear compression of the interstellar medium and its embedded magnetic field; the earliest failure, seemingly, was not detecting color gradients associated with the migration of OB stars whose formation is triggered downstream from the spiral shock front. We give the reasons for this apparent failure with an update on the current status of the problem of OB star formation, including its relationship to the feathering substructure of galactic spiral arms. Infrared images can show two-armed, grand design spirals, even when the optical and UV images show flocculent structures. We suggest how the nonlinear response of the interstellar gas, coupled with overlapping subharmonic resonances, might introduce chaotic behavior in the dynamics of the interstellar medium and Population I objects, even though the underlying forces to which they are subject are regular. We then move to a discussion of resonantly forced spiral density waves in a planetary ring and their relationship to the ideas of disk truncation, and the shepherding of narrow rings by satellites orbiting nearby. The back reaction of the rings on the satellites led to the prediction of planet migration in protoplanetary disks, which has had widespread application in the exploding data sets concerning hot Jupiters and extrasolar planetary systems. We then return to the issue of global normal modes in the stellar disk of spiral galaxies and its relationship to the QSSS hypothesis, where the central theoretical concepts involve waves with negative and positive surface densities of energy and angular

  20. Multislice CT as a Primary Screening Tool for the Prediction of an Involved Mesorectal Fascia and Distant Metastases in Primary Rectal Cancer : A Multicenter Study

    NARCIS (Netherlands)

    Wolberink, Steven V. R. C.; Beets-Tan, Regina G. H.; de Haas-Kock, Danielle F. M.; van de Jagt, Eric J.; Span, Mark M.; Wiggers, Theo

    PURPOSE: The purposes of this study were to assess whether multislice CT can identify tumors having a free or involved circumferential margin, to investigate the additional role of multislice CT as a "one-stop shopping'' staging tool for staging nodal and distant metastases. METHODS: A total of 250

  1. Investigation of logarithmic spiral nanoantennas at optical frequencies

    Science.gov (United States)

    Verma, Anamika; Pandey, Awanish; Mishra, Vigyanshu; Singh, Ten; Alam, Aftab; Dinesh Kumar, V.

    2013-12-01

    The first study is reported of a logarithmic spiral antenna in the optical frequency range. Using the finite integration technique, we investigated the spectral and radiation properties of a logarithmic spiral nanoantenna and a complementary structure made of thin gold film. A comparison is made with results for an Archimedean spiral nanoantenna. Such nanoantennas can exhibit broadband behavior that is independent of polarization. Two prominent features of logarithmic spiral nanoantennas are highly directional far field emission and perfectly circularly polarized radiation when excited by a linearly polarized source. The logarithmic spiral nanoantenna promises potential advantages over Archimedean spirals and could be harnessed for several applications in nanophotonics and allied areas.

  2. Galaxy Zoo: dust in spiral galaxies

    Science.gov (United States)

    Masters, Karen L.; Nichol, Robert; Bamford, Steven; Mosleh, Moein; Lintott, Chris J.; Andreescu, Dan; Edmondson, Edward M.; Keel, William C.; Murray, Phil; Raddick, M. Jordan; Schawinski, Kevin; Slosar, Anže; Szalay, Alexander S.; Thomas, Daniel; Vandenberg, Jan

    2010-05-01

    We investigate the effect of dust on spiral galaxies by measuring the inclination dependence of optical colours for 24276 well-resolved Sloan Digital Sky Survey (SDSS) galaxies visually classified via the Galaxy Zoo project. We find clear trends of reddening with inclination which imply a total extinction from face-on to edge-on of 0.7, 0.6, 0.5 and 0.4mag for the ugri passbands (estimating 0.3mag of extinction in z band). We split the sample into `bulgy' (early-type) and `discy' (late-type) spirals using the SDSS fracdeV (or fDeV) parameter and show that the average face-on colour of `bulgy' spirals is redder than the average edge-on colour of `discy' spirals. This shows that the observed optical colour of a spiral galaxy is determined almost equally by the spiral type (via the bulge-disc ratio and stellar populations), and reddening due to dust. We find that both luminosity and spiral type affect the total amount of extinction, with discy spirals at Mr ~ -21.5mag having the most reddening - more than twice as much as both the lowest luminosity and most massive, bulge-dominated spirals. An increase in dust content is well known for more luminous galaxies, but the decrease of the trend for the most luminous has not been observed before and may be related to their lower levels of recent star formation. We compare our results with the latest dust attenuation models of Tuffs et al. We find that the model reproduces the observed trends reasonably well but overpredicts the amount of u-band attenuation in edge-on galaxies. This could be an inadequacy in the Milky Way extinction law (when applied to external galaxies), but more likely indicates the need for a wider range of dust-star geometries. We end by discussing the effects of dust on large galaxy surveys and emphasize that these effects will become important as we push to higher precision measurements of galaxy properties and their clustering. This publication has been made possible by the participation of more than

  3. Analysis of spiral components in 16 galaxies

    International Nuclear Information System (INIS)

    Considere, S.; Athanassoula, E.

    1988-01-01

    A Fourier analysis of the intensity distributions in the plane of 16 spiral galaxies of morphological types from 1 to 7 is performed. The galaxies processed are NGC 300,598,628,2403,2841,3031,3198,3344,5033,5055,5194,5247,6946,7096,7217, and 7331. The method, mathematically based upon a decomposition of a distribution into a superposition of individual logarithmic spiral components, is first used to determine for each galaxy the position angle PA and the inclination ω of the galaxy plane onto the sky plane. Our results, in good agreement with those issued from different usual methods in the literature, are discussed. The decomposition of the deprojected galaxies into individual spiral components reveals that the two-armed component is everywhere dominant. Our pitch angles are then compared to the previously published ones and their quality is checked by drawing each individual logarithmic spiral on the actual deprojected galaxy images. Finally, the surface intensities for angular periodicities of interest are calculated. A choice of a few of the most important ones is used to elaborate a composite image well representing the main spiral features observed in the deprojected galaxies

  4. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  5. Sharp corners as sources of spiral pairs

    International Nuclear Information System (INIS)

    Biton, Y.; Rabinovitch, A.; Braunstein, D.; Friedman, M.; Aviram, I.

    2010-01-01

    It is demonstrated that using the FitzHugh-Nagumo model, stimulation of excitable media inside a region possessing sharp corners, can lead to the appearance of sources of spiral-pairs of sustained activity. The two conditions for such source creation are: The corners should be less than 120 deg. and the range of stimulating amplitudes should be small, occurring just above the threshold value and decreasing with the corner angle. The basic mechanisms driving the phenomenon are discussed. These include: A. If the corner angle is below 120 deg., the wave generated inside cannot emerge at the corner tip, resulting in the creation of two free edges which start spiraling towards each other. B. Spiraling must be strong enough; otherwise annihilation of the rotating arms would occur too soon to create a viable source. C. The intricacies of the different radii involved are elucidated. Possible applications in heart stimulation and in chemical reactions are considered.

  6. Principles of spiral CT: III. Quality assurance

    International Nuclear Information System (INIS)

    Suess, C.; Kalender, W.A.

    1998-01-01

    Since its introduction in 1989 spiral CT has gained wide clinical acceptance and meanwhile it covers a large range of CT applications. This new technology, however, has not yet been recognized and acknowledged in the national or international regulations on scanner quality assurance (QA) programs. The conventional QA procedures should be extended to check the distribution of resolution and noise within the image plane. Imaging performance in the axial direction constitutes one of the major advantages of spiral scanning. Therefore, the slice sensitivity profiles and the spatial and low-contrast resolution along the z-axis have to be assessed. The high demands on table feed accuracy require additional tests. We suggest phantoms and procedures to check and quantify these parameters. Thereby, we hope to support the ongoing discussion about spiral CT quality assurance. (orig.) [de

  7. Spiral loaded cavities for heavy ion acceleration

    International Nuclear Information System (INIS)

    Schempp, A.; Klein, H.

    1976-01-01

    A transmission line theory of the spiral resonator has been performed and the calculated and measured properties will be compared. Shunt impedances up to 50 MΩ/m have been measured. In a number of high power tests the structure has been tested and its electrical and mechanical stability has been investigated. The static frequency shift due to ponderomotoric forces was between 0.2 and 50 kHz/kW dependent on the geometrical parameters of the spirals. The maximum field strength obtained on the axis was 16 MV/m in pulsed operation and 9.2 MV/m in cw, corresponding to a voltage gain per cavity of up to 0.96 MV. The results show that spiral resonators are well suited as heavy ion accelerator cavities. (author)

  8. Organic carbon spiralling in stream ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Newbold, J D; Mulholland, P J; Elwood, J W; O' Neill, R V

    1982-01-01

    The term spiralling has been used to describe the combined processes of cycling and longitudinal transport in streams. As a measure or organic carbon spiralling, we introduced organic carbon turnover length, S, defined as the average or expected downstream distance travelled by a carbon atom between its entry or fixation in the stream and its oxidation. Using a simple model for organic carbon dynamics in a stream, we show that S is closely related to fisher and Likens' ecosystem efficiency. Unlike efficiency, however, S is independent of the length of the study reach, and values of S determined in streams of differing lengths can be compared. Using data from three different streams, we found the relationship between S and efficiency to agree closely with the model prediction. Hypotheses of stream functioning are discussed in the context of organic carbeon spiralling theory.

  9. Spiral arms, comets and terrestrial catastrophism

    International Nuclear Information System (INIS)

    Clube, S.V.M.; Napier, W.M.

    1982-01-01

    A review is presented of an hypothesis of terrestrial catastrophism in which comets grow in molecular clouds and are captured by the Sun as it passes through the spiral arms of the Galaxy. Assuming that comets are a major supplier of the Earth-crossing (Appollo) asteroid population, the latter fluctuates correspondingly and leads to episodes of terrestrial bombardment. Changes in the rotational momentum of core and mantle, generated by impacts, lead to episodes of magnetic field reversal and tectonic activity, while surface phenomena lead to ice-ages and mass extinctions. An episodic geophysical history with an interstellar connection is thus implied. If comets in spiral arms are necessary intermediaries in the process of star formation, the theory also has implications relating to early solar system history and galactic chemistry. These aspects are briefly discussed with special reference to the nature of spiral arms. (author)

  10. Considerations of an oscillating spiral universe cosmology

    International Nuclear Information System (INIS)

    Sachs, M.

    1989-01-01

    It is proposed that if the spiral configuration of galaxies is explicable in terms of the equations of motion of its constituent stars, as an expression of global laws of nature, then the universe as a whole may be similarly described in terms of the motions of its constituent galaxies with a similar spiral dynamics. With the functional form of the spiral paths in terms of Fresnel integrals, taken from solutions of equations in general relativity (from previous analyses of galactic configurations) the density of the universe at the big bang stage is determined. It is found to depend, numerically, on the neutron lifetime and the period of oscillation of the universe as a whole. There is some concluding discussion of the implications of this analysis of the matter of the universe at the big bang stage vis a vis the black hole state of matter

  11. Molecular clouds and galactic spiral structure

    International Nuclear Information System (INIS)

    Dame, T.M.

    1984-02-01

    Galactic CO line emission at 115 GHz was surveyed in order to study the distribution of molecular clouds in the inner galaxy. Comparison of this survey with similar H1 data reveals a detailed correlation with the most intense 21 cm features. To each of the classical 21 cm H1 spiral arms of the inner galaxy there corresponds a CO molecular arm which is generally more clearly defined and of higher contrast. A simple model is devised for the galactic distribution of molecular clouds. The modeling results suggest that molecular clouds are essentially transient objects, existing for 15 to 40 million years after their formation in a spiral arm, and are largely confined to spiral features about 300 pc wide

  12. Spiral CT manifestations of spherical pneumonia

    International Nuclear Information System (INIS)

    Li Xiaohong; Yang Hongwei; Xu Chunmin; Qin Xiu

    2008-01-01

    Objective: To explore the Spiral CT manifestations and differential diagnosis of spherical pneumonia. Methods: 18 cases of spherical pneumonia and 20 cases of peripheral pulmonary carcinoma were selected, both of them were confirmed by clinic and/or pathology. The SCT findings of both groups were compared retrospectively. Results: Main spiral CT findings of spherical pneumonia were showed as followings: square or triangular lesions adjacent to pleura; with irregular shape, blurry, slightly lobulated margin, sometimes with halo sign. Small inflammatory patches and intensified vascular markings around the lesions were seen. Lesions became smaller or vanished after short-term anti-inflammatory treatment. Conclusion: Spherical pneumonia showed some characteristics on Spiral CT scan, which are helpful in diagnosis and differential diagnosis of this disease. (authors)

  13. Spiral CT for evaluation of chest trauma

    International Nuclear Information System (INIS)

    Roehnert, W.; Weise, R.

    1997-01-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [de

  14. Simulations of the flocculent spiral M33: what drives the spiral structure?

    Science.gov (United States)

    Dobbs, C. L.; Pettitt, A. R.; Corbelli, E.; Pringle, J. E.

    2018-05-01

    We perform simulations of isolated galaxies in order to investigate the likely origin of the spiral structure in M33. In our models, we find that gravitational instabilities in the stars and gas are able to reproduce the observed spiral pattern and velocity field of M33, as seen in HI, and no interaction is required. We also find that the optimum models have high levels of stellar feedback which create large holes similar to those observed in M33, whilst lower levels of feedback tend to produce a large amount of small scale structure, and undisturbed long filaments of high surface density gas, hardly detected in the M33 disc. The gas component appears to have a significant role in producing the structure, so if there is little feedback, both the gas and stars organise into clear spiral arms, likely due to a lower combined Q (using gas and stars), and the ready ability of cold gas to undergo spiral shocks. By contrast models with higher feedback have weaker spiral structure, especially in the stellar component, compared to grand design galaxies. We did not see a large difference in the behaviour of Qstars with most of these models, however, because Qstars stayed relatively constant unless the disc was more strongly unstable. Our models suggest that although the stars produce some underlying spiral structure, this is relatively weak, and the gas physics has a considerable role in producing the large scale structure of the ISM in flocculent spirals.

  15. Neutrons for science (NFS) at spiral-2

    International Nuclear Information System (INIS)

    Ridikas, D.

    2005-01-01

    Both cross section measurements and various applications could be realised successfully using the high energy neutrons that will be produced at SPIRAL-2. Two particular cases were examined in more detail, namely: (a) neutron time-of-flight (nToF) measurements with pulsed neutron beams, and (b) material activation-irradiation with high-energy high-intensity neutron fluxes. Thanks to the high energy and high intensity neutron flux available, SPIRAL-2 offers a unique opportunity for material irradiations both for fission and fusion related research, tests of various detection systems and of resistance of electronics components to irradiations, etc. SPIRAL-2 also could be considered as an intermediate step towards new generation dedicated irradiation facilities as IFMIF previewed only beyond 2015. Equally, the interval from 0.1 MeV to 40 MeV for neutron cross section measurements is an energy range that is of particular importance for energy applications, notably accelerator driven systems (ADS) and Gen-IV fast reactors, as well as for fusion related devices. It is also the region where pre-equilibrium approaches are often used to link the low (evaporation) and high energy (intra-nuclear cascade) reaction models. With very intense neutron beams of SPIRAL-2 measurements of very low mass (often radioactive) targets and small cross sections become feasible in short experimental campaigns. Production of radioactive targets for dedicated physics experiments is also an attractive feature of SPIRAL-2. In brief, it was shown that SPIRAL-2 has got a remarkable potential for neutron based research both for fundamental physics and various applications. In addition, in the neutron energy range from a few MeV to, say, 35 MeV this research would have a leading position for the next 10-15 years if compared to other neutron facilities in operation or under construction worldwide. (author)

  16. Kidney spiral CT, indications, realization, results

    International Nuclear Information System (INIS)

    Braunschweig, R.; Beilicke, M.; Hundt, W.; Breiteneder, T.; Reiser, M.

    1999-01-01

    The introduction of spiral computed tomography (spiral CT) has vastly enriched the methodologically diversity of computer-tomographic scans. It allows for the recording of different perfusion or excretion stages of the kidney parenchyma of the urine draining paths by carrying out long-distance, phase-identical multiple examinations of the retroperitoneum. The description of the findings which are characterized by their local and contrasts behavior is possible. The following report describes the indications and technological process of kidney spiral CT using kidney-typical intravenous contrast media. Special emphasis is put on the advantages and limits of multiple phase spiral CT. Decisive preconditions are: 1. Specific clinical query, 2. selection of the corresponding phase contrasts of the kidneys and uretra or bladder, 3. exact technical and temporal adjustment of the acquisition parameters. Scanning times are in the range of seconds. The overall examination can be carried out quick and without any major strain on the part of the patient. A sound proof and a general differentiation of focal kideny lesions can be derived from the acquired data. This is also true for kidneys and ureters findings. Bladder findings can be localized and differentiated according to stage. More than two 'spiral acquisitions' should be carried out with restraint taking exposure to radiation into account. Due to the sound registration of focal lesions, its capability of reproduction and its short-time examination, the spiral CT of the kidneys can be said to be the most effective current scanning method of the retroperitoneum following clinical examinations and sonography. (orig.) [de

  17. Graphite target for the spiral project

    International Nuclear Information System (INIS)

    Putaux, J.C.; Ducourtieux, M.; Ferro, A.; Foury, P.; Kotfila, L.; Mueller, A.C.; Obert, J.; Pauwels, N.; Potier, J.C.; Proust, J.; Loiselet, M.

    1996-01-01

    A study of the thermal and physical properties of graphite targets for the SPIRAL project is presented. The main objective is to develop an optimized set-up both mechanically and thermally resistant, presenting good release properties (hot targets with thin slices). The results of irradiation tests concerning the mechanical and thermal resistance of the first prototype of SPIRAL target with conical geometry are presented. The micro-structural properties of the graphite target is also studied, in order to check that the release properties are not deteriorated by the irradiation. Finally, the results concerning the latest pilot target internally heated by an electrical current are shown. (author)

  18. Packing of equal discs on a parabolic spiral lattice

    International Nuclear Information System (INIS)

    Xudong, F.; Bursill, L.A.; Julin, P.

    1989-01-01

    A contact disc model is investigated to determine the most closely-packed parabolic spiral lattice. The most space-efficient packings have divergence angles in agreement with the priority ranking of natural spiral structures

  19. Collateral abdominal circulation in patient with Leriche's syndrome diagnosed with 64-row multislice computed tomography (MSCT)

    International Nuclear Information System (INIS)

    Staskiewicz, G.; Drop, A.

    2008-01-01

    Leriche's syndrome results from slowly developing occlusion of the abdominal aorta. It affects mainly middle-aged males. The blood flow distal to the occlusion site is secured by collateral circulation. Signs of Leriche's syndrome include claudication, gluteal pain and impotence. The paper presents a patient with Leriche's syndrome, in whom a detailed visualization of collateral circulation was obtained with multislice computed tomography angiography. Patient underwent surgical recanalization of the aorta with an excellent result. To our knowledge, the presented case is the first description of collateral circulation in Leriche's syndrome obtained with 64-row computed tomography. (author)

  20. A multislice theory of electron scattering in crystals including backscattering and inelastic effects.

    Science.gov (United States)

    Spiegelberg, Jakob; Rusz, Ján

    2015-12-01

    In the framework of the slice transition operator technique, a general multislice theory for electron scattering in crystals is developed. To achieve this generalization, we combine the approaches for inelastic scattering derived by Yoshioka [J. Phys. Soc. Jpn. 12, 6 (1957)] and backscattering based on the formalism of Chen and Van Dyck [Ultramicroscopy 70, 29-44 (1997)]. A computational realization of the obtained equations is suggested. The proposed computational scheme is tested on elastic backscattering of electrons, where we consider single backscattering in analogy to the computational scheme proposed by Chen and Van Dyck. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  2. A multi-slice gradient sequence for contrast enhanced MR diagnosis of intracranial tumours

    International Nuclear Information System (INIS)

    Schoerner, W.; Sander, B.; Kornmesser, W.; Laniado, M.; Nakamura, T.; Felix, R.

    1988-01-01

    A multi-slice gradient echo sequence (FLASH) was compared with a conventional spin-echo (SE) technique with regard to its value for contrast enhanced MR diagnosis. In 28 patients with cerebral tumours, SE images (SE 400/30; four images/3.4 minutes) and FLASH images (FLASH 315/14; 15 images/1.4 minutes) were obtained before and after gadolinium DTPA. After gadolinium-DTPA results were comparable for both techniques with respect to contrast enhancement, tumor contrast and delineation. Because of the higher efficiency of the FLASH 315/14 technique, this sequence is the method of choice for contrast enhanced cerebral MR imaging. (orig.) [de

  3. The dynamics of the spiral galaxy M81

    International Nuclear Information System (INIS)

    Visser, H.C.D.

    1978-01-01

    A detailed comparison of the observations of the spiral galaxy M81 with the density-wave theory for tightly-wound spirals is presented. In particular, hydrogen-line observations are compared with the nonlinear density-wave theory for the gas with the aim of constructing a density-wave model for the spiral galaxy M81

  4. Adaptation of the control system in view of SPIRAL integration

    International Nuclear Information System (INIS)

    Lecorche, E.

    1998-01-01

    As soon as the collaboration between the SPIRAL project and the Control Group has been defined, the first implementation of the SPIRAL control system started following various directions. Both the global hardware and software architectures has been specified and some practical works have been undertaken such as the Ethernet network installation or the first SPIRAL oriented software design and coding. (authors)

  5. Spiral kicker for the beam abort system

    Energy Technology Data Exchange (ETDEWEB)

    Martin, R.L.

    1983-01-01

    A brief study was carried out to determine the feasibility of a special kicker to produce a damped spiral beam at the beam dump for the beam abort system. There appears to be no problem with realizing this concept at a reasonably low cost.

  6. Spiral kicker for the beam abort system

    International Nuclear Information System (INIS)

    Martin, R.L.

    1983-01-01

    A brief study was carried out to determine the feasibility of a special kicker to produce a damped spiral beam at the beam dump for the beam abort system. There appears to be no problem with realizing this concept at a reasonably low cost

  7. Irrational Numbers Can "In-Spiral" You

    Science.gov (United States)

    Lewis, Leslie D.

    2007-01-01

    This article describes the instructional process of helping students visualize irrational numbers. Students learn to create a spiral, called "the wheel of Theodorus," which demonstrates irrational and rational lengths. Examples of student work help the reader appreciate the delightful possibilities of this project. (Contains 4 figures.)

  8. Importance of packing in spiral defect chaos

    Indian Academy of Sciences (India)

    We develop two measures to characterize the geometry of patterns exhibited by the state of spiral defect chaos, a weakly turbulent regime of Rayleigh-Bénard convection. These describe the packing of contiguous stripes within the pattern by quantifying their length and nearest-neighbor distributions. The distributions ...

  9. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  10. STRUCTURED MOLECULAR GAS REVEALS GALACTIC SPIRAL ARMS

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Tsuyoshi [Joint ALMA Office, Alonso de Cordova 3107, Vitacura, Santiago 763-0355 (Chile); Hasegawa, Tetsuo [NAOJ Chile Observatory, Joaquin Montero 3000 Oficina 702, Vitacura, Santiago 763-0409 (Chile); Koda, Jin, E-mail: sawada.tsuyoshi@nao.ac.jp [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800 (United States)

    2012-11-01

    We explore the development of structures in molecular gas in the Milky Way by applying the analysis of the brightness distribution function and the brightness distribution index (BDI) in the archival data from the Boston University-Five College Radio Astronomy Observatory {sup 13}CO J = 1-0 Galactic Ring Survey. The BDI measures the fractional contribution of spatially confined bright molecular emission over faint emission extended over large areas. This relative quantity is largely independent of the amount of molecular gas and of any conventional, pre-conceived structures, such as cores, clumps, or giant molecular clouds. The structured molecular gas traced by higher BDI is located continuously along the spiral arms in the Milky Way in the longitude-velocity diagram. This clearly indicates that molecular gas changes its structure as it flows through the spiral arms. Although the high-BDI gas generally coincides with H II regions, there is also some high-BDI gas with no/little signature of ongoing star formation. These results support a possible evolutionary sequence in which unstructured, diffuse gas transforms itself into a structured state on encountering the spiral arms, followed by star formation and an eventual return to the unstructured state after the spiral arm passage.

  11. Investigation of Spiral and Sweeping Holes

    Science.gov (United States)

    Thurman, Douglas; Poinsatte, Philip; Ameri, Ali; Culley, Dennis; Raghu, Surya; Shyam, Vikram

    2015-01-01

    Surface infrared thermography, hotwire anemometry, and thermocouple surveys were performed on two new film cooling hole geometries: spiral/rifled holes and fluidic sweeping holes. The spiral holes attempt to induce large-scale vorticity to the film cooling jet as it exits the hole to prevent the formation of the kidney shaped vortices commonly associated with film cooling jets. The fluidic sweeping hole uses a passive in-hole geometry to induce jet sweeping at frequencies that scale with blowing ratios. The spiral hole performance is compared to that of round holes with and without compound angles. The fluidic hole is of the diffusion class of holes and is therefore compared to a 777 hole and Square holes. A patent-pending spiral hole design showed the highest potential of the non-diffusion type hole configurations. Velocity contours and flow temperature were acquired at discreet cross-sections of the downstream flow field. The passive fluidic sweeping hole shows the most uniform cooling distribution but suffers from low span-averaged effectiveness levels due to enhanced mixing. The data was taken at a Reynolds number of 11,000 based on hole diameter and freestream velocity. Infrared thermography was taken for blowing rations of 1.0, 1.5, 2.0, and 2.5 at a density ration of 1.05. The flow inside the fluidic sweeping hole was studied using 3D unsteady RANS.

  12. High-displacement spiral piezoelectric actuators

    Science.gov (United States)

    Mohammadi, F.; Kholkin, A. L.; Jadidian, B.; Safari, A.

    1999-10-01

    A high-displacement piezoelectric actuator, employing spiral geometry of a curved piezoelectric strip is described. The monolithic actuators are fabricated using a layered manufacturing technique, fused deposition of ceramics, which is capable of prototyping electroceramic components with complex shapes. The spiral actuators (2-3 cm in diameter) consisted of 4-5 turns of a lead zirconate titanate ceramic strip with an effective length up to 28 cm. The width was varied from 0.9 to 1.75 mm with a height of 3 mm. When driven by the electric field applied across the width of the spiral wall, the tip of the actuator was found to displace in both radial and tangential directions. The tangential displacement of the tip was about 210 μm under the field of 5 kV/cm. Both the displacement and resonant frequency of the spirals could be tailored by changing the effective length and wall width. The blocking force of the actuator in tangential direction was about 1 N under the field of 5 kV/cm. These properties are advantageous for high-displacement low-force applications where bimorph or monomorph actuators are currently employed.

  13. Biofouling of spiral wound membrane systems

    NARCIS (Netherlands)

    Vrouwenvelder, J.S.

    2009-01-01

    Biofouling of spiral wound membrane systems High quality drinking water can be produced with membrane filtration processes like reverse osmosis (RO) and nanofiltration (NF). Because the global demand for fresh clean water is increasing, these membrane technologies will increase in importance in the

  14. Space charge effect in the spiral inflector

    International Nuclear Information System (INIS)

    Toprek, Dragan

    2000-01-01

    This paper presents the analytical and numerical theory of the space charge effects in the beam in the spiral inflector. It considers a simplified model of a 'straight' cylindrical beam by using a uniform particle distribution. Numerical results represented in this paper are obtained by using a modified version of the program CASINO

  15. Some optical properties of the spiral inflector

    International Nuclear Information System (INIS)

    Toprek, Dragan; Subotic, Krunoslav

    1999-01-01

    This paper compares some optical properties of different spiral inflectors using the program CASINO. The electric field distribution in the inflectors has been numerically calculated from an electric potential map produced by the program RELAX3D. The magnetic field is assumed to be constant. We have also made an effort to minimize the inflector fringe field using the RELAX3D program. (author)

  16. A nutrient’s downstream spiral

    Science.gov (United States)

    Indicators of a stream’s ability to remove nutrients provide insights on watershed integrity and stream habitat characteristics that are needed to help managers to restore stream ecosystem services. We used the Tracer Additon Spiraling Characterization Curve (TASCC) to mea...

  17. Spiral groove seal. [for hydraulic rotating shaft

    Science.gov (United States)

    Ludwig, L. P. (Inventor)

    1973-01-01

    Mating flat surfaces inhibit leakage of a fluid around a stationary shaft. A spiral groove pattern produces a pumping action toward the fluid when the shaft rotates which prevents leakage while a generated hydraulic lifting force separates the mating surfaces to minimize wear.

  18. Logarithmic spiral trajectories generated by Solar sails

    Science.gov (United States)

    Bassetto, Marco; Niccolai, Lorenzo; Quarta, Alessandro A.; Mengali, Giovanni

    2018-02-01

    Analytic solutions to continuous thrust-propelled trajectories are available in a few cases only. An interesting case is offered by the logarithmic spiral, that is, a trajectory characterized by a constant flight path angle and a fixed thrust vector direction in an orbital reference frame. The logarithmic spiral is important from a practical point of view, because it may be passively maintained by a Solar sail-based spacecraft. The aim of this paper is to provide a systematic study concerning the possibility of inserting a Solar sail-based spacecraft into a heliocentric logarithmic spiral trajectory without using any impulsive maneuver. The required conditions to be met by the sail in terms of attitude angle, propulsive performance, parking orbit characteristics, and initial position are thoroughly investigated. The closed-form variations of the osculating orbital parameters are analyzed, and the obtained analytical results are used for investigating the phasing maneuver of a Solar sail along an elliptic heliocentric orbit. In this mission scenario, the phasing orbit is composed of two symmetric logarithmic spiral trajectories connected with a coasting arc.

  19. The Spiral Curriculum. Research into Practice

    Science.gov (United States)

    Johnston, Howard

    2012-01-01

    The Spiral Curriculum is predicated on cognitive theory advanced by Jerome Bruner (1960), who wrote, "We begin with the hypothesis that any subject can be taught in some intellectually honest form to any child at any stage of development." In other words, even the most complex material, if properly structured and presented, can be understood by…

  20. Spiral Growth in Plants: Models and Simulations

    Science.gov (United States)

    Allen, Bradford D.

    2004-01-01

    The analysis and simulation of spiral growth in plants integrates algebra and trigonometry in a botanical setting. When the ideas presented here are used in a mathematics classroom/computer lab, students can better understand how basic assumptions about plant growth lead to the golden ratio and how the use of circular functions leads to accurate…

  1. The Spiral-Interactive Program Evaluation Model.

    Science.gov (United States)

    Khaleel, Ibrahim Adamu

    1988-01-01

    Describes the spiral interactive program evaluation model, which is designed to evaluate vocational-technical education programs in secondary schools in Nigeria. Program evaluation is defined; utility oriented and process oriented models for evaluation are described; and internal and external evaluative factors and variables that define each…

  2. The handedness of historiated spiral columns.

    Science.gov (United States)

    Couzin, Robert

    2017-09-01

    Trajan's Column in Rome (AD 113) was the model for a modest number of other spiral columns decorated with figural, narrative imagery from antiquity to the present day. Most of these wind upwards to the right, often with a congruent spiral staircase within. A brief introductory consideration of antique screw direction in mechanical devices and fluted columns suggests that the former may have been affected by the handedness of designers and the latter by a preference for symmetry. However, for the historiated columns that are the main focus of this article, the determining factor was likely script direction. The manner in which this operated is considered, as well as competing mechanisms that might explain exceptions. A related phenomenon is the reversal of the spiral in a non-trivial number of reproductions of the antique columns, from Roman coinage to Renaissance and baroque drawings and engravings. Finally, the consistent inattention in academic literature to the spiral direction of historiated columns and the repeated publication of erroneous earlier reproductions warrants further consideration.

  3. Nobeyama CO Atlas of Nearby Spiral Galaxies

    Science.gov (United States)

    Kuno, N.; Nakai, N.; Sorai, K.; Sato, N..; Yamauchi, A.; Tosaki, T.; Shioya, Y.; Vila-Vilaró, B.; Nishiyama, K.; Ishihara, Y.; Cepa, J.

    BEARS is a 25-beam focal plane array receiver mounted on the Nobeyama 45-m telescope. The combination of the large dish size of the telescope with the excellent performance of this receiver makes it an ideal tool for mapping observations of extended regions of the sky. We present here one of its current applications in a CO mapping survey of nearby spiral galaxies.

  4. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  5. Nutrient spiraling in streams and river networks

    Science.gov (United States)

    Ensign, Scott H.; Doyle, Martin W.

    2006-12-01

    Over the past 3 decades, nutrient spiraling has become a unifying paradigm for stream biogeochemical research. This paper presents (1) a quantitative synthesis of the nutrient spiraling literature and (2) application of these data to elucidate trends in nutrient spiraling within stream networks. Results are based on 404 individual experiments on ammonium (NH4), nitrate (NO3), and phosphate (PO4) from 52 published studies. Sixty-nine percent of the experiments were performed in first- and second-order streams, and 31% were performed in third- to fifth-order streams. Uptake lengths, Sw, of NH4 (median = 86 m) and PO4 (median = 96 m) were significantly different (α = 0.05) than NO3 (median = 236 m). Areal uptake rates of NH4 (median = 28 μg m-2 min-1) were significantly different than NO3 and PO4 (median = 15 and 14 μg m-2 min-1, respectively). There were significant differences among NH4, NO3, and PO4 uptake velocity (median = 5, 1, and 2 mm min-1, respectively). Correlation analysis results were equivocal on the effect of transient storage on nutrient spiraling. Application of these data to a stream network model showed that recycling (defined here as stream length ÷ Sw) of NH4 and NO3 generally increased with stream order, while PO4 recycling remained constant along a first- to fifth-order stream gradient. Within this hypothetical stream network, cumulative NH4 uptake decreased slightly with stream order, while cumulative NO3 and PO4 uptake increased with stream order. These data suggest the importance of larger rivers to nutrient spiraling and the need to consider how stream networks affect nutrient flux between terrestrial and marine ecosystems.

  6. Utilization of the ion traps by SPIRAL

    International Nuclear Information System (INIS)

    Le Brun, C.; Lienard, E.; Mauger, F.; Tamain, B.

    1997-01-01

    An ion trap is a device capable of confine particles, ions or atoms in a well-controlled environment isolated from any exterior perturbations. There are different traps. They are utilized to collect or stock ions, to cool them after in order to subject them to high precision measurement of masses, magnetic moments, hyperfine properties, beta decay properties, etc. Some dozen of traps are currently used all over the world to study stable or radioactive ions.. SPIRAL has been designed and built to produce radioactive ions starting from various heavy ion beams. SPIRAL has the advantage that the projectile parameters, the target and the energy can be chosen to optimize the production in various regions of the nuclear chart. Also, in SPIRAL it is possible to extract more rapidly the radioactive ions formed in the targets. In addition, in SPIRAL the multicharged ion production in a ECR source is possible. The utilization of multicharged ions is indeed very useful for fast mass measurements or for the study of the interaction between the nucleus and the electronic cloud. Finally, utilization of a ion trap on SPIRAL can be designed first at the level of production target by installing a low energy output line. Than, the trap system could be up-graded and brought to its full utilization behind of the recoil spectrometer. It must be capable of selecting and slowing down the ions produced in the reactions (fusion transfer, very inelastic collisions, etc.) induced by the radioactive ions accelerated in CIME. At present, the collaboration is debating on the most favored subject to study and the most suited experimental setups. The following subjects were selected: ion capture, purification and manipulation; isomers (separation and utilization); mass measurements; hyperfine interactions; lifetimes, nuclear electric cloud; β decays; study of the N = Z nuclei close to the proton drip line; physical and chemical properties of transuranium systems

  7. Molecular clouds and galactic spiral structure

    International Nuclear Information System (INIS)

    Dame, T.M.

    1983-01-01

    Galactic CO line emission at 115 GHz has been surveyed in the region 12 0 less than or equal to l less than or equal to 60 0 and -1 0 less than or equal to b less than or equal to 1 0 in order to study the distribution of molecular clouds in the inner galaxy; an inner strip 0 0 .5 wide has been sampled every beamwidth (0 0 .125), the rest every two beamwidths. Comparison of the survey with similar HI data reveals a detailed correlation with the most intense 21-cm features, implying that the CO and HI trace the same galactic features and have the same large-scale kinematics. To each of the classical 21-cm (HI) spiral arms of the inner galaxy there corresponds a CO molecular arm which is generally more clearly defined and of higher contrast. A simple model is developed in which all of the CO emission from the inner galaxy arises from spiral arms. The modeling results suggest that molecular clouds are essentially transient objects, existing for 15 to 40 million years after their formation in a spiral arm, and are largely confined to spiral features about 300 pc wide. A variety of methods are employed to estimate distances and masses for the largest clouds detected by the inner-galaxy survey and a catalogue is compiled. The catalogued clouds, the largest of which have masses of several 10 6 M/sub sunmass/ and linear dimensions in excess of 100 pc, are found to be excellent spiral-arm tracers. One of the nearest of the clouds, that associated with the supernova remnant W44, is fully mapped in both CO and 13 CO and is discussed in detail

  8. Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, Mate [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary); Janos Szentagothai PhD School, MR Research Centre, Budapest (Hungary); National Institute of Clinical Neuroscience, Department of Neuroradiology, Budapest (Hungary); Hermann, Petra; Vidnyanszky, Zoltan; Gal, Viktor [Hungarian Academy of Sciences, Brain Imaging Centre, Research Centre for Natural Sciences, Budapest (Hungary)

    2018-03-15

    To maintain alertness and to remain motionless during scanning represent a substantial challenge for patients/subjects involved in both clinical and research functional magnetic resonance imaging (fMRI) examinations. Therefore, availability and application of new data acquisition protocols allowing the shortening of scan time without compromising the data quality and statistical power are of major importance. Higher order category-selective visual cortical areas were identified individually, and rapid event-related fMRI design was used to compare three different sampling rates (TR = 2000, 1000, and 410 ms, using state-of-the-art simultaneous multislice imaging) and four different scanning lengths to match the statistical power of the traditional scanning methods to high sampling-rate design. The results revealed that ∝ 4 min of the scan time with 1 Hz (TR = 1000 ms) sampling rate and ∝ 2 min scanning at ∝ 2.5 Hz (TR = 410 ms) sampling rate provide similar localization sensitivity and selectivity to that obtained with 11-min session at conventional, 0.5 Hz (TR = 2000 ms) sampling rate. Our findings suggest that task-based fMRI examination of clinical population prone to distress such as presurgical mapping experiments might substantially benefit from the reduced (20-40%) scanning time that can be achieved by the application of simultaneous multislice sequences. (orig.)

  9. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    Directory of Open Access Journals (Sweden)

    Prijo Sidipratomo

    2014-08-01

    Full Text Available BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic Medicine and Radiology of Dr. Cipto Mangunkusumo Hospital were selected based on inclusion criteria. Then MSCT scan and autopsy were conducted. MSCT scan and autopsy results were compared and analyzed. RESULTS: There were 491 postmortem cases of blunt head injury. However, only 10 cases fulfilled inclusion criteria. Subarachnoid haemorrhages were identified 100% with MSCT scan and 80% with autopsy. Cerebral oedemas were identified 100% either with MSCT scan and autopsy. Subdural haemorrhages were identified 100% with MSCT scan, while 50% with autopsy. Multiple fractures were identified 80% with MSCT scan, while 40% with auto. CONCLUSIONS: MSCT scan showed a sensitive detection in finding abnormalities in close blunt head injury. Therefore it could be as an alternative choice of examination in close blunt head injury cases. KEYWORDS: multislice computed tomography scan, postmortem, blunt head injury, autopsy.

  10. Use of pattern recognition for unaliasing simultaneously acquired slices in simultaneous multislice MR fingerprinting.

    Science.gov (United States)

    Jiang, Yun; Ma, Dan; Bhat, Himanshu; Ye, Huihui; Cauley, Stephen F; Wald, Lawrence L; Setsompop, Kawin; Griswold, Mark A

    2017-11-01

    The purpose of this study is to accelerate an MR fingerprinting (MRF) acquisition by using a simultaneous multislice method. A multiband radiofrequency (RF) pulse was designed to excite two slices with different flip angles and phases. The signals of two slices were driven to be as orthogonal as possible. The mixed and undersampled MRF signal was matched to two dictionaries to retrieve T 1 and T 2 maps of each slice. Quantitative results from the proposed method were validated with the gold-standard spin echo methods in a phantom. T 1 and T 2 maps of in vivo human brain from two simultaneously acquired slices were also compared to the results of fast imaging with steady-state precession based MRF method (MRF-FISP) with a single-band RF excitation. The phantom results showed that the simultaneous multislice imaging MRF-FISP method quantified the relaxation properties accurately compared to the gold-standard spin echo methods. T 1 and T 2 values of in vivo brain from the proposed method also matched the results from the normal MRF-FISP acquisition. T 1 and T 2 values can be quantified at a multiband acceleration factor of two using our proposed acquisition even in a single-channel receive coil. Further acceleration could be achieved by combining this method with parallel imaging or iterative reconstruction. Magn Reson Med 78:1870-1876, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-10-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  12. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    International Nuclear Information System (INIS)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko

    2001-01-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  13. Can 16-detector multislice CT exclude skeletal lesions during tumour staging? Implications for the cancer patient

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Beadsmoore, Clare J.; Courtney, Helen M.; Harish, Srinivasan; Bearcroft, Philip W.P.; Dixon, Adrian K.; Cheow, Heok K.; Balan, Kottekkattu K.; Kaptoge, Stephen; Win, Thida

    2006-01-01

    Current imaging guidelines recommend that many cancer patients undergo soft-tissue staging by computed tomography (CT) whilst the bones are imaged by skeletal scintigraphy (bone scan). New CT technology has now made it feasible, for the first time, to perform a detailed whole-body skeletal CT. This advancement could save patients from having to undergo duplicate investigations. Forty-three patients with known malignancy were investigated for bone metastasis using skeletal scintigraphy and 16-detector multislice CT. Both studies were performed within six weeks of each other. Whole-body images were taken 4 h after injection of 500 Mbq 99m Tc-MDP using a gamma camera. CT was performed on a 16-detector multislice CT machine from the vertex to the knee. The examinations were reported independently and discordant results were compared at follow-up. Statistical equivalence between the two techniques was tested using the Newcombe-Wilson method within the pre-specified equivalence limits of ±20%. Scintigraphy detected bone metastases in 14/43 and CT in 13/43 patients. There were seven discordances; four cases were positive on scintigraphy, but negative on CT; three cases were positive on CT and negative on scintigraphy. There was equivalence between scintigraphy and CT in detecting bone metastases within ±19% equivalence limits. Patients who have undergone full whole-body staging on 16-detector CT may not need additional skeletal scintigraphy. This should shorten the cancer patient's diagnostic pathway. (orig.)

  14. Acquiring 4D thoracic CT scans using a multislice helical method

    International Nuclear Information System (INIS)

    Keall, P J; Starkschall, G; Shukla, H; Forster, K M; Ortiz, V; Stevens, C W; Vedam, S S; George, R; Guerrero, T; Mohan, R

    2004-01-01

    Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm 3 ). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies

  15. Multislice simulations for in-situ HRTEM studies of nanostructured magnesium hydride at ambient hydrogen pressure

    Energy Technology Data Exchange (ETDEWEB)

    Surrey, Alexander, E-mail: a.surrey@ifw-dresden.de [IFW Dresden, Institute for Metallic Materials, P.O. Box 270116, D-01171 Dresden (Germany); Institut für Festkörperphysik, Technische Universität Dresden, D-01062 Dresden (Germany); Schultz, Ludwig [IFW Dresden, Institute for Metallic Materials, P.O. Box 270116, D-01171 Dresden (Germany); Institut für Festkörperphysik, Technische Universität Dresden, D-01062 Dresden (Germany); Rellinghaus, Bernd, E-mail: b.rellinghaus@ifw-dresden.de [IFW Dresden, Institute for Metallic Materials, P.O. Box 270116, D-01171 Dresden (Germany)

    2017-04-15

    Highlights: • Multislice HRTEM contrast simulations of a windowed environmental cell. • Study of Mg and MgH2 nanocrystals as model system in hydrogen at ambient pressure. • Investigation of spatial resolution and contrast depending on specimen thickness, defocus, and hydrogen pressure. • Atomic resolution is expected for specimens as thin as 5  nm. - Abstract: The use of transmission electron microscopy (TEM) for the structural characterization of many nanostructured hydrides, which are relevant for solid state hydrogen storage, is hindered due to a rapid decomposition of the specimen upon irradiation with the electron beam. Environmental TEM allows to stabilize the hydrides by applying a hydrogen back pressure of up to 4.5 bar in a windowed environmental cell. The feasibility of high-resolution TEM (HRTEM) investigations of light weight metals and metal hydrides in such a “nanoreactor” is studied theoretically by means of multislice HRTEM contrast simulations using Mg and its hydride phase, MgH{sub 2}, as model system. Such a setup provides the general opportunity to study dehydrogenation and hydrogenation reactions at the nanoscale under technological application conditions. We analyze the dependence of both the spatial resolution and the HRTEM image contrast on parameters such as the defocus, the metal/hydride thickness, and the hydrogen pressure in order to explore the possibilities and limitations of in-situ experiments with windowed environmental cells. Such simulations may be highly valuable to pre-evaluate future experimental studies.

  16. Three-phase CT examination of the pancreatobiliary region using multislice CT with 1-mm collimation

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Ikeda, Mitsuru; Suzuki, Koujiro; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo

    2005-01-01

    The purpose of this study was to evaluate the degree of contrast enhancement and accuracy of imaging of the circulatory phase in the first-pass, second-pass, and third-pass acquisitions in the pancreato-biliary region with 1-mm collimation obtained by multislice computed tomography (CT). In 53 patients, two sequential acquisitions from the porta hepatis to the pancreas were performed during a single breath-hold, followed by a third-pass acquisition including the liver beginning 15 sec after the second-pass acquisition. Contrast enhancement in each acquisition was measured in the aorta, portal vein and its branches, and pancreas. Four experienced radiologists graded using four-point scoring whether or not each acquisition was appropriate for imaging of the arterial phase, pancreatic phase, and portal venous phase. Aortic enhancement was highest at the beginning of the second-pass acquisition. The portal and splenic veins and pancreas showed maximum enhancement in the second-pass acquisition, while the superior mesenteric vein showed maximum enhancement in the third-pass acquisition. In the visual assessment, significantly higher grades were achieved in the first-pass, second-pass, and third-pass acquisitions with regard to imaging of the arterial phase, pancreatic phase, and portal venous phase, respectively. Multislice CT permits the acquisition of three distinct circulatory phases (arterial, pancreatic, and portal venous phases) in the pancreatobiliary region with 1-mm collimation. (author)

  17. Multislice simulations for in-situ HRTEM studies of nanostructured magnesium hydride at ambient hydrogen pressure

    International Nuclear Information System (INIS)

    Surrey, Alexander; Schultz, Ludwig; Rellinghaus, Bernd

    2017-01-01

    Highlights: • Multislice HRTEM contrast simulations of a windowed environmental cell. • Study of Mg and MgH2 nanocrystals as model system in hydrogen at ambient pressure. • Investigation of spatial resolution and contrast depending on specimen thickness, defocus, and hydrogen pressure. • Atomic resolution is expected for specimens as thin as 5  nm. - Abstract: The use of transmission electron microscopy (TEM) for the structural characterization of many nanostructured hydrides, which are relevant for solid state hydrogen storage, is hindered due to a rapid decomposition of the specimen upon irradiation with the electron beam. Environmental TEM allows to stabilize the hydrides by applying a hydrogen back pressure of up to 4.5 bar in a windowed environmental cell. The feasibility of high-resolution TEM (HRTEM) investigations of light weight metals and metal hydrides in such a “nanoreactor” is studied theoretically by means of multislice HRTEM contrast simulations using Mg and its hydride phase, MgH_2, as model system. Such a setup provides the general opportunity to study dehydrogenation and hydrogenation reactions at the nanoscale under technological application conditions. We analyze the dependence of both the spatial resolution and the HRTEM image contrast on parameters such as the defocus, the metal/hydride thickness, and the hydrogen pressure in order to explore the possibilities and limitations of in-situ experiments with windowed environmental cells. Such simulations may be highly valuable to pre-evaluate future experimental studies.

  18. Evaluation of endometrial carcinoma by multislice dynamic MR imaging with Turbo FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, Mari [Okayama Univ. (Japan). School of Medicine

    1995-04-01

    The purpose of this study was to investigate the usefulness of multislice dynamic MR imaging with Turbo FLASH in assessing myometrial invasion by endometrial carcinoma. Dynamic MR imaging was performed with bolus injection of Gd-DTPA and with 1.5-T Siemens Magnetom imager using Turbo FLASH. Thirty-six endometrial carcinomas were evaluated with pathologic correlation. Junctional zone showed more rapid contrast enhancement effects than myometrium even after menopause. Contrast to noise ratio between junctional zone and endometrial carcinoma was the highest about fifty seconds after bolus injection. Only at that time could the degree of invasion to junctional zone in post-menopausal women whose junctional zones could not be seen on T{sub 2}-weighted images or contrast-enhanced T{sub 1}-weighted images be evaluated correctly. The accuracy in assessing myometrial invasion with T{sub 2}-weighted images, postcontrast T{sub 1}-weighted images, and dynamic MR imaging was 75%, 81% and 89% respectively. Though there was no statistically significant difference, multislice dynamic imaging with Turbo FLASH technique is considered to be a useful imaging method for the pre-operative assessment of myometrial invasion by endometrial carcinoma. (author).

  19. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Doerfler, Arnd; Deuerling-Zheng, Yu; Boese, Jan; Zellerhoff, Michael; Schwab, Stefan

    2011-01-01

    We tested the hypothesis that Flat Detector computed tomography (FD-CT) with intravenous contrast medium would allow the calculation of whole brain cerebral blood volume (CBV) mapping (FD-CBV) and would correlate with multislice Perfusion CT (PCT). Twenty five patients were investigated with FD-CBV and PCT. Correlation of the CBV maps of both techniques was carried out with measurements from six anatomical regions from both sides of the brain. Mean values of each region and the correlation coefficient were calculated. Bland-Altman analysis was performed to compare the two different imaging techniques. The image and data quality of both PCT and FD-CBV were suitable for evaluation in all patients. The mean CBV values of FD-CBV and PCT showed only minimal differences with overlapping standard deviation. The correlation coefficient was 0.79 (p < 0.01). Bland-Altman analysis showed a mean difference of -0.077 ± 0.48 ml/100 g between FD-CBV and PCT CBV measurements, indicating that FD-CBV values were only slightly lower than those of PCT. CBV mapping with intravenous contrast medium using Flat Detector CT compared favourably with multislice PCT. The ability to assess cerebral perfusion within the angiographic suite may improve the management of ischaemic stroke and evaluation of the efficacy of dedicated therapies. (orig.)

  20. Safe Control for Spiral Recovery of Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Chang-Jian Ru

    2014-01-01

    Full Text Available With unmanned aerial vehicles (UAVs widely used in both military and civilian fields, many events affecting their safe flying have emerged. That UAV’s entering into the spiral is such a typical safety issue. To solve this safety problem, a novel recovery control approach is proposed. First, the factors of spiral are analyzed. Then, based on control scheduling of state variables and nonlinear dynamic inversion control laws, the spiral recovery controller is designed to accomplish guidance and control of spiral recovery. Finally, the simulation results have illustrated that the proposed control method can ensure the UAV autonomous recovery from spiral effectively.

  1. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT

    NARCIS (Netherlands)

    Parsa, A.; Ibrahim, N.; Hassan, B.; van der Stelt, P.; Wismeijer, D.

    2015-01-01

    Objectives The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the

  2. Role of multislice CT and magnetic resonance cholangiography in preoperative evaluation of potential donor in living related liver transplantation

    Directory of Open Access Journals (Sweden)

    Hossam M. Abdel-Rahman

    2016-03-01

    Conclusion: Multislice CT is a valuable tool in the evaluation of potential living liver donors that provides complete information on the hepatic vascular anatomy, the liver parenchyma, and volumetric measurements. MRC with a 3.0-T MR system demonstrates the preoperative biliary evaluation very well with a high accuracy rate.

  3. Differences in atherosclerotic plaque burden and morphology between type 1 and 2 diabetes as assessed by multislice computed tomography

    NARCIS (Netherlands)

    Djaberi, Roxana; Schuijf, Joanne D.; Boersma, Eric; Kroft, Lucia J. M.; Pereira, Alberto M.; Romijn, Johannes A.; Scholte, Arthur J.; Jukema, J. Wouter; Bax, Jeroen J.

    2009-01-01

    OBJECTIVE It is unclear whether the coronary atherosclerotic plaque burden is similar in patients with type 1 and type 2 diabetes. By using multislice computed tomography (MSCT), the presence, degree, and morphology of coronary artery disease (CAD) in patients with type 1 and type 2 diabetes were

  4. How does a planet excite multiple spiral arms?

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-01-01

    Protoplanetary disk simulations show that a single planet excites multiple spiral arms in the background disk, potentially supported by the multi-armed spirals revealed with recent high-resolution observations in some disks. The existence of multiple spiral arms is of importance in many aspects. It is empirically found that the arm-to-arm separation increases as a function of the planetary mass, so one can use the morphology of observed spiral arms to infer the mass of unseen planets. In addition, a spiral arm opens a radial gap as it steepens into a shock, so when a planet excites multiple spiral arms it can open multiple gaps in the disk. Despite the important implications, however, the formation mechanism of multiple spiral arms has not been fully understood by far.In this talk, we explain how a planet excites multiple spiral arms. The gravitational potential of a planet can be decomposed into a Fourier series, a sum of individual azimuthal modes having different azimuthal wavenumbers. Using a linear wave theory, we first demonstrate that appropriate sets of Fourier decomposed waves can be in phase, raising a possibility that constructive interference among the waves can produce coherent structures - spiral arms. More than one spiral arm can form since such constructive interference can occur at different positions in the disk for different sets of waves. We then verify this hypothesis using a suite of two-dimensional hydrodynamic simulations. Finally, we present non-linear behavior in the formation of multiple spiral arms.

  5. Model for the local spiral structure of the galaxy

    International Nuclear Information System (INIS)

    Humphreys, R.M.

    1976-01-01

    The spatial distribution of the most luminous stars, associations, clusters, and H II regions in the region l = 270 0 to 30 0 reveal a major spiral arm, Sagittarius-Carina, which can be observed to 9 or 10 kpc from the sun in the direction l = 290 0 to 305 0 . Evidence is also presented for a spur at l = 305 0 to 310 0 on the inner side of the Saggitarius-Carina arm. The noncircular motions observed in the Carina and Sagittarius spiral features agree in both magnitude and direction and support the suggestion that Sagittarius-Carina is a major spiral arm. A model is presented for the local spiral structure with wide, massive, spiral arms which show fragmentation in our region of the Galaxy. On the basis of the optical spiral structure, the Milky Way is an Sc type spiral galaxy, perhaps of the M 101 type

  6. Mechanism of spiral formation in heterogeneous discretized excitable media.

    Science.gov (United States)

    Kinoshita, Shu-ichi; Iwamoto, Mayuko; Tateishi, Keita; Suematsu, Nobuhiko J; Ueyama, Daishin

    2013-06-01

    Spiral waves on excitable media strongly influence the functions of living systems in both a positive and negative way. The spiral formation mechanism has thus been one of the major themes in the field of reaction-diffusion systems. Although the widely believed origin of spiral waves is the interaction of traveling waves, the heterogeneity of an excitable medium has recently been suggested as a probable cause. We suggest one possible origin of spiral waves using a Belousov-Zhabotinsky reaction and a discretized FitzHugh-Nagumo model. The heterogeneity of the reaction field is shown to stochastically generate unidirectional sites, which can induce spiral waves. Furthermore, we found that the spiral wave vanished with only a small reduction in the excitability of the reaction field. These results reveal a gentle approach for controlling the appearance of a spiral wave on an excitable medium.

  7. Multislice CT cholangiography without biliary contrast agent: technique and initial clinical results in the assessment of patients with biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Zandrino, F.; Benzi, L.; Ferretti, M.L.; Ferrando, R.; Reggiani, G.; Musante, F. [Department of Radiology, Azienda Ospedaliera ' ' SS Antonio e Biagio e C. Arrigo' ' , Alessandria (Italy)

    2002-05-01

    Our objective was to describe our technique for multislice CT cholangiography without cholangiographic contrast agent, and to present our preliminary clinical results. Thirty-seven patients with suspected biliary obstruction were studied. A multislice CT unit was used with the following technical parameters: 2.5-mm collimation; 7.5-mm/s table speed; pitch 6; 0.8-s rotation time; 300 mA; 120 kVp; 18- to 24-s scan time; scan volume ranging from the hepatic dome to below the pancreatic head; 70-s delay after injection of 150 ml of iodinated contrast agent at 4 ml/s. No biliary contrast material was given; oral iodinated contrast agent was administered to opacify bowel loops. Axial, multiplanar reformatted, and minimum intensity projection images were evaluated. The CT findings were compared with the gold standard techniques: endoscopic retrograde cholangiography (ERCP) in 30 patients, percutaneous transhepatic cholangiography in 5, and intraoperative cholangiography in 2. In 5 patients with ampullary lesions biopsy was made during ERCP, 9 underwent surgery, and 11 US-guided fine-needle aspiration. Bile ducts appeared hypodense within the surrounding enhanced structures. Regarding the site of obstruction, agreement between multislice CT and conventional cholangiography was observed in all cases. One patient presented negative findings on both CT and ERCP. In 31 of 36 (86%) patients, multislice CT cholangiography without cholangiographic contrast agent correctly assessed the cause of bile duct obstruction. Multislice CT cholangiography without cholangiographic contrast agent seems to be a promising diagnostic tool in the assessment of patients with bile duct obstruction. (orig.)

  8. Multislice CT cholangiography without biliary contrast agent: technique and initial clinical results in the assessment of patients with biliary obstruction

    International Nuclear Information System (INIS)

    Zandrino, F.; Benzi, L.; Ferretti, M.L.; Ferrando, R.; Reggiani, G.; Musante, F.

    2002-01-01

    Our objective was to describe our technique for multislice CT cholangiography without cholangiographic contrast agent, and to present our preliminary clinical results. Thirty-seven patients with suspected biliary obstruction were studied. A multislice CT unit was used with the following technical parameters: 2.5-mm collimation; 7.5-mm/s table speed; pitch 6; 0.8-s rotation time; 300 mA; 120 kVp; 18- to 24-s scan time; scan volume ranging from the hepatic dome to below the pancreatic head; 70-s delay after injection of 150 ml of iodinated contrast agent at 4 ml/s. No biliary contrast material was given; oral iodinated contrast agent was administered to opacify bowel loops. Axial, multiplanar reformatted, and minimum intensity projection images were evaluated. The CT findings were compared with the gold standard techniques: endoscopic retrograde cholangiography (ERCP) in 30 patients, percutaneous transhepatic cholangiography in 5, and intraoperative cholangiography in 2. In 5 patients with ampullary lesions biopsy was made during ERCP, 9 underwent surgery, and 11 US-guided fine-needle aspiration. Bile ducts appeared hypodense within the surrounding enhanced structures. Regarding the site of obstruction, agreement between multislice CT and conventional cholangiography was observed in all cases. One patient presented negative findings on both CT and ERCP. In 31 of 36 (86%) patients, multislice CT cholangiography without cholangiographic contrast agent correctly assessed the cause of bile duct obstruction. Multislice CT cholangiography without cholangiographic contrast agent seems to be a promising diagnostic tool in the assessment of patients with bile duct obstruction. (orig.)

  9. Research on comparison of exposure with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode in coronary multi-slice spiral CT angiography

    International Nuclear Information System (INIS)

    Liu Bin; Guo Senlin; Wei Lan; Fei Xiaolu; Bai Mei

    2009-01-01

    Objective: The objective of this article was to compare patients dose with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode during coronary MSCT angiography. Methods: The research was based on phantom experiment and computer simulation to get the mean value of peak skin dose data and effective dose data respectively and to analyze deterministic and stochastic radiation risk. Results: The peak skin dose using ECG mode alone and using ECG and CAREDose 4D mode with the same image noise level was (87.4 ± 0.9) and (45.9 ± 1.2) mGy respectively. Effective dose was 17 and 10 rosy for ECG mode and ECG and CAREDose 4D mode respectively. Comparing with ECG mode alone, ECG and CAREDose 4D mode reduced organ dose of gonad, red marrow, lung, stomach, breast and thyroid by 40.0%, 36.7%, 39.3%, 37.7%, 38.8% and 38.9%, respectively. Conclusion: Results showed that ECG and CAREDose 4D mode can reduce radiation dose effectively comparing using ECG mode alone, and that ECG and CAREDose 4D mode should be widely applied clinically with appropriate initial settings. (authors)

  10. Analysis of failure modes in multislice computed tomography during primary trauma survey; Analyse von Verzoegerungen der Schockraumdiagnostik bei Einsatz der Mehrschicht-Spiral-Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Siebers, C.; Stegmaier, J.; Kirchhoff, C.; Kanz, K.G. [Chirurgische Klinik, Klinikum der Univ. Muenchen (Germany); Wirth, S.; Koerner, M.; Pfeifer, K.J. [Inst. fuer Klinische Radiologie, Klinikum der Univ. Muenchen (Germany); Kay, M.V. [Plansafe GmbH, Muenchen (Germany)

    2008-08-15

    Purpose: in the case of major trauma, immediate recognition and treatment of life-threatening conditions are essential. An increasing number of European trauma centers use MSCT during the primary trauma survey due to its high diagnostic precision and speed. However, there is currently little empirical data about failures in this process to practice quality assurance. The aim of this study was to evaluate this process under operating resuscitation conditions and to identify failure modes that caused delays in completion. Materials and methods: an independent study monitor documented the course of trauma room treatment during a 10-month period. The inclusion criteria were patients who were admitted directly from the accident scene and the study monitor was present at the time of admission. Results: according to our ATLS-based trauma algorithm whole-body CT (WBCT) consists of non-contrast head CT (CCT) and contrast-enhanced trunk CT (TCT). 57 trauma patients receiving 45 WBCT. 5 single CCT and 4 single TCT studies were evaluated. After initial resuscitation, CCT was obtained within 17 min of trauma room admission (IQR 13.0 - 20.0). In 20% (95%CI 9 - 31%) of the cases, a CCT delay of median 5.0 min (IQR 3.8 - 8.0) was observed caused by e.g. earings, piercings and ECG cables in the scan field or intoxicated patients. Contrast-enhanced TCT was performed after 23.0 min (IQR 19.0 - 27.0). Due to preventable errors 12 of the 49 TCT studies were delayed (25%95%CI 12 - 37%) for 5 min (IQR 3.0 - 8.0). Conclusion: under ''front line'' conditions every fifth CCT and every fourth TCT study was completed with a median delay of 5 min. An independent process analysis revealed that unpreventable delays were due to uncooperative patients or system failure. Preventable delays were due to errors such as short intravenous lines or deviation from trauma room algorithms. Preventable delays could be avoided by addressing human and technical aspects such as revising checklists and functional architecture of the trauma bay. The failure mode and effect analysis (FMEA) method would assure quality in this process. (orig.)

  11. Radial distributions of arm-gas offsets as an observational test of spiral theories

    OpenAIRE

    Baba, Junichi; Morokuma-Matsui, Kana; Egusa, Fumi

    2015-01-01

    Theories of stellar spiral arms in disk galaxies can be grouped into two classes based on the longevity of a spiral arm. Although the quasi-stationary density wave theory supposes that spirals are rigidly-rotating, long-lived patterns, the dynamic spiral theory predicts that spirals are differentially-rotating, transient, recurrent patterns. In order to distinguish between the two spiral models from observations, we performed hydrodynamic simulations with steady and dynamic spiral models. Hyd...

  12. Motion estimation and compensation in dynamic spiral CT reconstruction; Estimation et compensation de mouvement en reconstruction dynamique de tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St

    2004-07-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  13. Spiral optical designs for nonimaging applications

    Science.gov (United States)

    Zamora, Pablo; Benítez, Pablo; Miñano, Juan C.; Vilaplana, Juan; Buljan, Marina

    2011-10-01

    Manufacturing technologies as injection molding or embossing specify their production limits for minimum radii of the vertices or draft angle for demolding, for instance. In some demanding nonimaging applications, these restrictions may limit the system optical efficiency or affect the generation of undesired artifacts on the illumination pattern. A novel manufacturing concept is presented here, in which the optical surfaces are not obtained from the usual revolution symmetry with respect to a central axis (z axis), but they are calculated as free-form surfaces describing a spiral trajectory around z axis. The main advantage of this new concept lies in the manufacturing process: a molded piece can be easily separated from its mold just by applying a combination of rotational movement around axis z and linear movement along axis z, even for negative draft angles. Some of these spiral symmetry examples will be shown here, as well as their simulated results.

  14. Diagnosing extracranial atherosclerotic diseases with spiral CT

    International Nuclear Information System (INIS)

    Moran, C.J.; Vannier, M.W.; Erickson, K.K.; Broderick, D.F.; Kido, D.K.; Yoffie, R.L.

    1991-01-01

    This paper reports that this discovery study was performed to determine whether extracranial carotid artery plaques could be diagnosed with a new CT technique (spiral CT) that allows nondistorted three-dimensional (3D) reconstructions in the z axis. Twenty carotid arteries were examined with spiral CT in normal volunteers and in patients suspected of having atherosclerotic plaques in the extracranial carotid arteries. The Somatom Plus CT table was advanced at a constant rate, the x-ray tube was continuously rotated, and 3D data were continuously acquired. Sixty milliliters of nonionic contrast medium was injected intravenously previous to and during the acquisition of data. The carotid bifurcations were identified in all patients. Planar images, similar to conventional intraarterial angiograms, were routinely produced from the volumetric CT data

  15. Status of the SPIRAL2 injector commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Thuillier, T., E-mail: thuillier@lpsc.in2p3.fr; Angot, J.; Jacob, J.; Lamy, T.; Sole, P. [LPSC, Université Grenoble Alpes, CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex (France); Barué, C.; Bertrand, P.; Canet, C.; Ferdinand, R.; Flambard, J.-L.; Jardin, P.; Lemagnen, F.; Maunoury, L.; Osmond, B. [GANIL, CNRS/IN2P3, Bvd Henri Becquerel, BP 55027, 14076 Caen Cedex 5 (France); Biarrotte, J. L. [IPN Orsay, Université Paris Sud, CNRS/IN2P3, 15 rue Georges Clémenceau, 91406 Orsay Cedex (France); Denis, J.-F.; Roger, A.; Touzery, R.; Tuske, O.; Uriot, D. [Irfu, CEA Saclay, DSM/Irfu/SACM, 91191 Gif Sur Yvette (France); and others

    2016-02-15

    The SPIRAL2 injector, installed in its tunnel, is currently under commissioning at GANIL, Caen, France. The injector is composed of two low energy beam transport lines: one is dedicated to the light ion beam production, the other to the heavy ions. The first light ion beam, created by a 2.45 GHz electron cyclotron resonance ion source, has been successfully produced in December 2014. The first beam of the PHOENIX V2 18 GHz heavy ion source was analyzed on 10 July 2015. A status of the SPIRAL2 injector commissioning is given. An upgrade of the heavy ion source, named PHOENIX V3 aimed to replace the V2, is presented. The new version features a doubled plasma chamber volume and the high charge state beam intensity is expected to increase by a factor of 1.5 to 2 up to the mass ∼50. A status of its assembly is proposed.

  16. Rolling motions in an inner spiral arm

    International Nuclear Information System (INIS)

    Strauss, F.M.; Poeppel, W.

    1976-01-01

    Hydrogen line observations made at low galactic latitudes for l=318degree, 326degree, 334degree, and 337degree show the presence of velocity gradients in latitude in the nearest inner spiral arm, similar to those found by other observations in different regions. Maximum velocity change is about 10 km s -1 for l=337degree. By generating synthetic line profiles constructed from a model spiral arm, several possible causes of these ''rolling motions'' were studied, such as a vertical displacement or a tilt of the arm (which failed to account for the observations) and rotation or shearing in the arm. It was futher shown that a typical arm can maintain such a motion (approx. =75 km s -1 kpc -1 ) with its own gravitational potential. The results are used to study the origin and tilt of Gould's Belt

  17. Stationary spiral flow in polytropic stellar models

    Science.gov (United States)

    Pekeris, C. L.

    1980-01-01

    It is shown that, in addition to the static Emden solution, a self-gravitating polytropic gas has a dynamic option in which there is stationary flow along spiral trajectories wound around the surfaces of concentric tori. The motion is obtained as a solution of a partial differential equation which is satisfied by the meridional stream function, coupled with Poisson's equation and a Bernoulli-type equation for the pressure