WorldWideScience

Sample records for ecg electrodes accurately

  1. Accurate Interpretation of the 12-Lead ECG Electrode Placement: A Systematic Review

    Science.gov (United States)

    Khunti, Kirti

    2014-01-01

    Background: Coronary heart disease (CHD) patients require monitoring through ECGs; the 12-lead electrocardiogram (ECG) is considered to be the non-invasive gold standard. Examples of incorrect treatment because of inaccurate or poor ECG monitoring techniques have been reported in the literature. The findings that only 50% of nurses and less than…

  2. Insulated ECG electrodes

    Science.gov (United States)

    Portnoy, W. M.; David, R. M.

    1973-01-01

    Insulated, capacitively coupled electrode does not require electrolyte paste for attachment. Other features of electrode include wide range of nontoxic material that may be employed for dielectric because of sputtering technique used. Also, electrode size is reduced because there is no need for external compensating networks with FET operational amplifier.

  3. Pocket ECG electrode

    Science.gov (United States)

    Lund, Gordon F. (Inventor)

    1982-01-01

    A low-noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free-ranging subject. The electrode comprises a pocket-shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

  4. Contact dermatitis caused by ECG electrode paste.

    Science.gov (United States)

    Cochran, R J; Rosen, T

    1980-12-01

    A case of contact dermatitis caused by ECG electrode cream is presented and the pertinent literature is reviewed. Our patient was found to be allergic to propylene glycol. Patch-testing remains an invaluable tool in the evaluation of patients suspected of being allergic to ECG paste, creams, and gels.

  5. Wearable Textile Electrodes for ECG Measurement

    Directory of Open Access Journals (Sweden)

    Lukas Vojtech

    2013-01-01

    Full Text Available The electrocardiogram (ECG is one of the most important parameters for monitoring of the physiological state of a person. Currently available systems for ECG monitoring are both stationary and wearable, but the comfort of the monitored person is not at a satisfactory level because these systems are not part of standard clothing. This article is therefore devoted to the development and measurement of wearable textile electrodes for ECG measurement device with high comfort for the user. The electrode material is made of electrically conductive textile. This creates a textile composite that guarantees high comfort for the user while ensuring good quality of ECG measurements. The composite is implemented by a carrier (a T-shirt with flame retardant and sensing electrodes embroidered with yarn based on a mixture of polyester coated with silver nanoparticles and cotton. The electrodes not only provide great comfort but are also antibacterial and antiallergic due to silver nanoparticles.

  6. Quantification of motion artifact in ECG electrode design.

    Science.gov (United States)

    Kearney, Kenneth; Thomas, Chris; McAdams, Eric

    2007-01-01

    We have developed a more accurate and reproducible method of quantifying motion artifact in ECG (electrocardiogram) electrodes to assist in electrode assessment and design. It uses an algorithm developed by Sensor Technology & Devices Ltd. to reliably overcome the variation in results due to differing skin types and other causes of spurious readings such as reproducibility of movements used. The method combines a clear, concise experimental protocol with a software package and DSP algorithm to produce a transferable result for one pair of electrodes that can be used for comparison.

  7. Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cunguang Lou

    2016-11-01

    Full Text Available This paper describes the development of a graphene-based dry flexible electrocardiography (ECG electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM, and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults.

  8. The ECG measurement in the bathtub using the insulated electrodes.

    Science.gov (United States)

    Lim, Yong Kyu; Kim, Ko Keun; Park, Kwang Suk

    2004-01-01

    The ECG recording in the bathtub was studied using insulated electrode. Prior studies of the ECG recording in the bathtub used conductive electrodes having some problems such as the possibility of the electric shock and sensitivity to contamination of the electrode surfaces. The insulated electrodes were made of copper plate coated with PET film. The electrodes were attached on bathtub at both sides of the chest. High-input-impedance amplifier was designed to amplify ECG signal sensed by insulated electrodes of high impedance. The recorded signals in this study were noisier than those recorded with conventional conductive electrodes. But the R peaks in the recorded signals were large enough to be auto-detected. Further study will improve SNR by reducing of power line noise and common-mode noise.

  9. The feasibility of bench tests for disposable ECG electrode adhesiveness.

    Science.gov (United States)

    Baker, C D; Schoenberg, A A; Booth, H E

    1979-01-01

    The feasibility of recommending one standard bench test that adequately qualifies electrode adhesives for clinical use was examined by UBTL. Small strips, cut from whole, commercially available disposable ECG electrodes, were attached to three types of surfaces, and samples of each type of electrode were peel tested at 15 minutes, 8 hours, and 48 hours after attachment. A program was developed to average, display, and calculate peel strength parameters. Analysis of the data showed that (a) the peel strength of electrodes varied by more than a factor of 10 when measured on human skin, and by more than a factor of 3 when measured on bench test surfaces, and (b) the peel strength of the electrode adhesive strips did not correlate with intact electrode loss on ambulatory subjects. Therefore, UBTL could not recommend one bench test that would measure adhesion performance for all electrode types appropriate for inclusion in an AAMI ECG electrode standard.

  10. A controlled study of a new ECG electrode system.

    Science.gov (United States)

    Sheffield, L T; Roitman, D I; Kansal, S

    1978-07-01

    A newly marketed resting ECG electrode system was compared with conventional metal suction and plate electrodes, electrode cream and patient cable. Two experienced technicians were given special training in the use of the new electrode, electrolyte and patient cable system and alternated daily in using new and conventional equipment. Nearly equal numbers of perfect-scoring ECGs were recorded with each system, attesting to the impartiality of the technicians. A total of 1,062 ECGs were evaluated, 554 with the new system and 508 with the conventional one. ECG tracings were evaluated by electrocardiographers unaware of which system was used for each. A quantitative scoring system was used to measure the technical quality of each tracing in terms of baseline drift, powerline artifact and myographic plus miscellaneous artifacts. The new system received mean scores of 2.33, 3.08, and 2.72, respectively, while the conventional electrodes received scores of 2.56, 3.03 and 2.79. We concluded that the two types of electrodes produced ECGs of essentially equal quality.

  11. Amplifier input impedance in dry electrode ECG recording.

    Science.gov (United States)

    Assambo, Cedric; Burke, Martin J

    2009-01-01

    This paper presents a novel approach for designing the front-end of instrumentation amplifiers for use in dry electrode recording of the human electrocardiogram (ECG). The method relies on information provided by the characterization of the skin-electrode interface and the analysis of low frequency ECG criteria defined by international standards. Marginal measurements of capacitive elements of the skin-electrode interface as small as 0.01 microF, suggest values of input impedance in the order of 1.3 GOmega. However, results in 99% of the data analyzed indicate that a recording amplifier providing an input impedance of 500 MOmega should ensure clear signal sensing without distortion.

  12. Automatic detection of ECG electrode misplacement: a tale of two algorithms.

    Science.gov (United States)

    Xia, Henian; Garcia, Gabriel A; Zhao, Xiaopeng

    2012-09-01

    Artifacts in an electrocardiogram (ECG) due to electrode misplacement can lead to wrong diagnoses. Various computer methods have been developed for automatic detection of electrode misplacement. Here we reviewed and compared the performance of two algorithms with the highest accuracies on several databases from PhysioNet. These algorithms were implemented into four models. For clean ECG records with clearly distinguishable waves, the best model produced excellent accuracies (> = 98.4%) for all misplacements except the LA/LL interchange (87.4%). However, the accuracies were significantly lower for records with noise and arrhythmias. Moreover, when the algorithms were tested on a database that was independent from the training database, the accuracies may be poor. For the worst scenario, the best accuracies for different types of misplacements ranged from 36.1% to 78.4%. A large number of ECGs of various qualities and pathological conditions are collected every day. To improve the quality of health care, the results of this paper call for more robust and accurate algorithms for automatic detection of electrode misplacement, which should be developed and tested using a database of extensive ECG records.

  13. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    Science.gov (United States)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  14. Robust and accurate anomaly detection in ECG artifacts using time series motif discovery.

    Science.gov (United States)

    Sivaraks, Haemwaan; Ratanamahatana, Chotirat Ann

    2015-01-01

    Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods.

  15. Surgical staple as a transcutaneous transducer for ECG electrodes in burnt skin: safe surgical monitoring in major burns.

    Science.gov (United States)

    Sofos, Stratos S; Tehrani, Hamid; Shokrollahi, Kayvan; James, M I

    2013-06-01

    It is often difficult to apply traditional ECG electrodes on patients with extensive burns due to a large operative site, compromise of sterility, the fact that traditional placement would be within the operative site or because stick-on pads cannot stick due to prep solution, bleeding and other factors. We present an effective solution based on our experience, of using a common staple or "clip" where the ECG electrode is attached. We can see the patient in the prone position with the back having been debrided and grafted. This technical improvisation gives clinicians the ability to monitor safely and accurately the patients' physiological parameters.

  16. Design of a smart ECG garment based on conductive textile electrode and flexible printed circuit board.

    Science.gov (United States)

    Cai, Zhipeng; Luo, Kan; Liu, Chengyu; Li, Jianqing

    2017-08-09

    A smart electrocardiogram (ECG) garment system was designed for continuous, non-invasive and comfortable ECG monitoring, which mainly consists of four components: Conductive textile electrode, garment, flexible printed circuit board (FPCB)-based ECG processing module and android application program. Conductive textile electrode and FPCB-based ECG processing module (6.8 g, 55 mm × 53 mm × 5 mm) are identified as two key techniques to improve the system's comfort and flexibility. Preliminary experimental results verified that the textile electrodes with circle shape, 40 mm size in diameter, and 5 mm thickness sponge are best suited for the long-term ECG monitoring application. The tests on the whole system confirmed that the designed smart garment can obtain long-term ECG recordings with high signal quality.

  17. Performance Evaluation of Plain Weave and Honeycomb Weave Electrodes for Human ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Xueliang Xiao

    2017-01-01

    Full Text Available Long-time monitoring of physiological parameters can scrutinize human health conditions so as to use electrocardiogram (ECG for diagnosis of some human’s chronic cardiovascular diseases. The continuous monitoring requires the wearable electrodes to be breathable, flexible, biocompatible, and skin-affinity friendly. Weave electrodes are innovative materials to supply these potential performances. In this paper, four conductive weave electrodes in plain and honeycomb weave patterns were developed to monitor human ECG signals. A wearable belt platform was developed to mount such electrodes for acquisition of ECG signals using a back-end electronic circuit and a signal transfer unit. The performance of weave ECG electrodes was evaluated in terms of skin-electrode contacting impedance, comfortability, ECG electrical characteristics, and signal fidelity. Such performances were then compared with the values from Ag/AgCl reference electrode. The test results showed that lower skin-electrode impedance, higher R-peak amplitude, and signal-to-noise ratio (SNR value were obtained with the increased density of conductive filaments in weave and honeycomb weave electrode presented higher comfort but poorer signal quality of ECG. This study inspires an acceptable way of weave electrodes in long- and real-time of human biosignal monitoring.

  18. Performance of human body communication-based wearable ECG with capacitive coupling electrodes.

    Science.gov (United States)

    Sakuma, Jun; Anzai, Daisuke; Wang, Jianqing

    2016-09-01

    Wearable electrocardiogram (ECG) is attracting much attention in daily healthcare applications, and human body communication (HBC) technology provides an evident advantage in making the sensing electrodes of ECG also working for transmission through the human body. In view of actual usage in daily life, however, non-contact electrodes to the human body are desirable. In this Letter, the authors discussed the ECG circuit structure in the HBC-based wearable ECG for removing the common mode noise when employing non-contact capacitive coupling electrodes. Through the comparison of experimental results, they have shown that the authors' proposed circuit structure with the third electrode directly connected to signal ground can provide an effect on common mode noise reduction similar to the usual drive-right-leg circuit, and a sufficiently good acquisition performance of ECG signals.

  19. Development of standard test methods for evaluating defibrillation recovery characteristics of disposable ECG electrodes.

    Science.gov (United States)

    Schoenberg, A A; Booth, H E; Lyon, P C

    1979-01-01

    A clinically relevant test for the measurement of defibrillation overload recovery of prefilled disposable ECG electrodes was developed and is proposed for use in an ECG electrode standard under development by AAMI. Defibrillation overload voltages and currents, as well as electrode polarization recovery voltages, were first measured in animal tests on 12 types of electrodes to allow correlation with various bench tests using a capacitor discharge at 10, 200, or 1000 V. Current overloads absorbed by the electrodes under worst conditions in animal tests were in the range of 2 percent of the defibrillation current flowing through the chest. These overloads were absorbed by most Ag-AgCl electrodes without excessive polarization. However, stainless steel, brass, and tin electrodes tended to polarize to levels that would saturate many ECG monitors. A standard bench test using a 200-V 10-muF capacitor was recommended for inclusion in the AAMI standard to determine whether electrodes are acceptable for use during defibrillation.

  20. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring.

    Science.gov (United States)

    Jung, Ha-Chul; Moon, Jin-Hee; Baek, Dong-Hyun; Lee, Jae-Hee; Choi, Yoon-Young; Hong, Joung-Sook; Lee, Sang-Hoon

    2012-05-01

    We fabricated a carbon nanotube (CNT)/ polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

  1. Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position

    Science.gov (United States)

    Prats-Boluda, G.; Ye-Lin, Y.; Bueno-Barrachina, JM; Rodriguez de Sanabria, R.; Garcia-Casado, J.

    2016-02-01

    To overcome the limited spatial resolution of standard 12-lead ECG recordings, concentric ring electrodes (CRE) have been proposed to provide valuable data for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. Although theoretical studies indicate that the dimensions of the CRE regulate the depth of the electric dipoles sensed by these electrodes, this has not been experimentally confirmed. The aim of this work was to analyze the influence of CRE dimensions and position of a wireless multi-CRE sensor node on the cardiac signal recorded. For this, four wireless multichannel ECG recording nodes based on flexible multi-ring electrodes were placed at positions CMV1 (position comparable to V1), CMV2, CMV4R and CMV5; each node providing three bipolar concentric ECG signals (BC-ECG). Standard 12-lead ECG and 12 BC-ECG signals were recorded in 29 volunteers. The results revealed that a ring with an outer diameter of 33.5 mm achieves a balance between the ease-of-use and spatial resolution of smaller electrodes and improved detectability and higher amplitudes of signals from larger ring electrodes. Although a standard 12-lead ECG outperforms BC-ECC recordings in detectability of cardiac waves, if the relative amplitude of the wave is also considered, BC-ECG at CMV1 proved superior at picking up atrial activity. In fact, in most of the BC-ECG signals picked up at CMV1, P1 and P2 atrial activity waves were more clearly identified than in simultaneous 12-Lead ECG signals. Likewise, BC-ECG signals revealed higher spatial resolution in detecting anomalous electrical activity in local regions, such as impaired intraventricular driving, or atrioventricular blocks. Finally, the wireless multi-CRE sensor node provides enhanced comfort and handling to both patient and clinician over wired systems.

  2. A Novel 12-Lead ECG T-Shirt with Active Electrodes

    Directory of Open Access Journals (Sweden)

    Anna Boehm

    2016-11-01

    Full Text Available We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403. The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.

  3. A novel approach for an ECG electrode integrated into a transcutaneous sensor.

    Science.gov (United States)

    Hölscher, U

    1987-01-01

    The integration of an ECG-electrode into a common transcutaneous sensor allows simple handling and leads to a reduction of the physiological stress of pre-term infants. Furthermore it may allow future replacement of an invasive method to measure the ECG under labour by a non-invasive one.

  4. Practical Non-contact ECG Electrodes for Prep-free Monitoring Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cognionics has developed a high-quality, low-noise, dry/non-contact ECG electrode that can obtain signals even through layers of clothing without any skin...

  5. A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.

    Science.gov (United States)

    Cho, Hakyung; Lee, Joo Hyeon

    2015-09-01

    Smart clothing is a sort of wearable device used for ubiquitous health monitoring. It provides comfort and efficiency in vital sign measurements and has been studied and developed in various types of monitoring platforms such as T-shirt and sports bra. However, despite these previous approaches, smart clothing for electrocardiography (ECG) monitoring has encountered a serious shortcoming relevant to motion artifacts caused by wearer movement. In effect, motion artifacts are one of the major problems in practical implementation of most wearable health-monitoring devices. In the ECG measurements collected by a garment, motion artifacts are usually caused by improper location of the electrode, leading to lack of contact between the electrode and skin with body motion. The aim of this study was to suggest a design for ECG-monitoring clothing contributing to reduction of motion artifacts. Based on the clothing science theory, it was assumed in this study that the stability of the electrode in a dynamic state differed depending on the electrode location in an ECG-monitoring garment. Founded on this assumption, effects of 56 electrode positions were determined by sectioning the surface of the garment into grids with 6 cm intervals in the front and back of the bodice. In order to determine the optimal locations of the ECG electrodes from the 56 positions, ECG measurements were collected from 10 participants at every electrode position in the garment while the wearer was in motion. The electrode locations indicating both an ECG measurement rate higher than 80.0 % and a large amplitude during motion were selected as the optimal electrode locations. The results of this analysis show four electrode locations with consistently higher ECG measurement rates and larger amplitudes amongst the 56 locations. These four locations were abstracted to be least affected by wearer movement in this research. Based on this result, a design of the garment-formed ECG monitoring platform

  6. A low-power portable ECG sensor interface with dry electrodes

    Science.gov (United States)

    Xiaofei, Pu; Lei, Wan; Hui, Zhang; Yajie, Qin; Zhiliang, Hong

    2013-05-01

    This paper describes a low-power portable sensor interface dedicated to sensing and processing electrocardiogram (ECG) signals. Dry electrodes were employed in this ECG sensor, which eliminates the need of conductive gel and avoids complicated and mandatory skin preparation before electrode attachment. This ECG sensor system consists of two ICs, an analog front-end (AFE) and a successive approximation register analog-to-digital converter (SAR ADC) containing a relaxation oscillator. This proposed design was fabricated in a 0.18 μm 1P6M standard CMOS process. The AFE for extracting the biopotential signals is essential in this ECG sensor. In measurements, the AFE obtains a mid-band gain of 45 dB, a bandwidth from 0.6 to 160 Hz, and a total input referred noise of 2.8 μV rms while consuming 1 μW from the 1.8 V supply. The noise efficiency factor (NEF) of our design is 3.4. After conditioning, the amplified ECG signal is digitized by a 12-bit SAR ADC with 61.8 dB SNDR and 220 fJ/conversion-step. Finally, a complete ECG sensor interface with three dry copper electrodes is demonstrated in real-word setting, showing successful recordings of a capture ECG waveform.

  7. A low-power portable ECG sensor interface with dry electrodes

    Institute of Scientific and Technical Information of China (English)

    Pu Xiaofei; Wan Lei; Zhang Hui; Qin Yajie; Hong Zhiliang

    2013-01-01

    This paper describes a low-power portable sensor interface dedicated to sensing and processing electrocardiogram (ECG) signals.Dry electrodes were employed in this ECG sensor,which eliminates the need of conductive gel and avoids complicated and mandatory skin preparation before electrode attachment.This ECG sensor system consists of two ICs,an analog front-end (AFE) and a successive approximation register analog-to-digital converter (SAR ADC) containing a relaxation oscillator.This proposed design was fabricated in a 0.18 μm 1P6M standard CMOS process.The AFE for extracting the biopotential signals is essential in this ECG sensor.In measurements,the AFE obtains a mid-band gain of 45 dB,a bandwidth from 0.6 to 160 Hz,and a total input referred noise of 2.8 μV rms while consuming 1 μW from the 1.8 V supply.The noise efficiency factor (NEF) of our design is 3.4.After conditioning,the amplified ECG signal is digitized by a 12-bit SAR ADC with 61.8 dB SNDR and 220 fJ/conversion-step.Finally,a complete ECG sensor interface with three dry copper electrodes is demonstrated in real-word setting,showing successful recordings of a capture ECG waveform.

  8. Skin-electrode impedance measurement during ECG acquisition: method’s validation

    Science.gov (United States)

    Casal, Leonardo; La Mura, Guillermo

    2016-04-01

    Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.

  9. Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions

    Directory of Open Access Journals (Sweden)

    Tharoeun Thap

    2016-04-01

    Full Text Available We proposed new electrodes that are applicable for electrocardiogram (ECG monitoring under freshwater- and saltwater-immersion conditions. Our proposed electrodes are made of graphite pencil lead (GPL, a general-purpose writing pencil. We have fabricated two types of electrode: a pencil lead solid type (PLS electrode and a pencil lead powder type (PLP electrode. In order to assess the qualities of the PLS and PLP electrodes, we compared their performance with that of a commercial Ag/AgCl electrode, under a total of seven different conditions: dry, freshwater immersion with/without movement, post-freshwater wet condition, saltwater immersion with/without movement, and post-saltwater wet condition. In both dry and post-freshwater wet conditions, all ECG-recorded PQRST waves were clearly discernible, with all types of electrodes, Ag/AgCl, PLS, and PLP. On the other hand, under the freshwater- and saltwater-immersion conditions with/without movement, as well as post-saltwater wet conditions, we found that the proposed PLS and PLP electrodes provided better ECG waveform quality, with significant statistical differences compared with the quality provided by Ag/AgCl electrodes.

  10. Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions

    Science.gov (United States)

    Thap, Tharoeun; Yoon, Kwon-Ha; Lee, Jinseok

    2016-01-01

    We proposed new electrodes that are applicable for electrocardiogram (ECG) monitoring under freshwater- and saltwater-immersion conditions. Our proposed electrodes are made of graphite pencil lead (GPL), a general-purpose writing pencil. We have fabricated two types of electrode: a pencil lead solid type (PLS) electrode and a pencil lead powder type (PLP) electrode. In order to assess the qualities of the PLS and PLP electrodes, we compared their performance with that of a commercial Ag/AgCl electrode, under a total of seven different conditions: dry, freshwater immersion with/without movement, post-freshwater wet condition, saltwater immersion with/without movement, and post-saltwater wet condition. In both dry and post-freshwater wet conditions, all ECG-recorded PQRST waves were clearly discernible, with all types of electrodes, Ag/AgCl, PLS, and PLP. On the other hand, under the freshwater- and saltwater-immersion conditions with/without movement, as well as post-saltwater wet conditions, we found that the proposed PLS and PLP electrodes provided better ECG waveform quality, with significant statistical differences compared with the quality provided by Ag/AgCl electrodes. PMID:27092502

  11. Novel Conductive Carbon Black and Polydimethlysiloxane ECG Electrode: A Comparison with Commercial Electrodes in Fresh, Chlorinated, and Salt Water.

    Science.gov (United States)

    Noh, Yeonsik; Bales, Justin R; Reyes, Bersain A; Molignano, Jennifer; Clement, Amanda L; Pins, George D; Florian, John P; Chon, Ki H

    2016-08-01

    In this study, we evaluated the performance of two novel conductive carbon black (CB) and polydimethlysiloxane (PDMS) bio-potential electrodes, with and without an integrated flexible copper mesh, against commercially available electrodes (Polar(®) textile, Silver-coated textile, and carbon rubber). The electrodes were tested in three types of water (fresh/unfiltered, chlorinated, and salt water). Our testing revealed that our CB/PDMS electrode with integrated copper mesh provided a high-fidelity ECG signal morphologies without any amplitude degradation in all of the types of water tested (N = 10). The non-meshed CB/PDMS electrodes were also subjected to a long-term durability test by the US Navy SCUBA divers during which the electrodes maintained ECG signal quality for a 6 h period of continuous use. The results of a material degradation analysis revealed the CB/PDMS composite material does not exhibit significant changes in physical integrity after prolonged exposure to the test conditions. The newly developed meshed CB/PDMS electrodes have the potential to be used in a wide variety of both dry and wet environments including the challenge of obtaining ECG signals in salt water environments.

  12. Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording

    Directory of Open Access Journals (Sweden)

    Yun-Hsuan Chen

    2014-12-01

    Full Text Available Conventional gel electrodes are widely used for biopotential measurements, despite important drawbacks such as skin irritation, long set-up time and uncomfortable removal. Recently introduced dry electrodes with rigid metal pins overcome most of these problems; however, their rigidity causes discomfort and pain. This paper presents dry electrodes offering high user comfort, since they are fabricated from EPDM rubber containing various additives for optimum conductivity, flexibility and ease of fabrication. The electrode impedance is measured on phantoms and human skin. After optimization of the polymer composition, the skin-electrode impedance is only ~10 times larger than that of gel electrodes. Therefore, these electrodes are directly capable of recording strong biopotential signals such as ECG while for low-amplitude signals such as EEG, the electrodes need to be coupled with an active circuit. EEG recordings using active polymer electrodes connected to a clinical EEG system show very promising results: alpha waves can be clearly observed when subjects close their eyes, and correlation and coherence analyses reveal high similarity between dry and gel electrode signals. Moreover, all subjects reported that our polymer electrodes did not cause discomfort. Hence, the polymer-based dry electrodes are promising alternatives to either rigid dry electrodes or conventional gel electrodes.

  13. Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording

    Science.gov (United States)

    Chen, Yun-Hsuan; de Beeck, Maaike Op; Vanderheyden, Luc; Carrette, Evelien; Mihajlović, Vojkan; Vanstreels, Kris; Grundlehner, Bernard; Gadeyne, Stefanie; Boon, Paul; Van Hoof, Chris

    2014-01-01

    Conventional gel electrodes are widely used for biopotential measurements, despite important drawbacks such as skin irritation, long set-up time and uncomfortable removal. Recently introduced dry electrodes with rigid metal pins overcome most of these problems; however, their rigidity causes discomfort and pain. This paper presents dry electrodes offering high user comfort, since they are fabricated from EPDM rubber containing various additives for optimum conductivity, flexibility and ease of fabrication. The electrode impedance is measured on phantoms and human skin. After optimization of the polymer composition, the skin-electrode impedance is only ∼10 times larger than that of gel electrodes. Therefore, these electrodes are directly capable of recording strong biopotential signals such as ECG while for low-amplitude signals such as EEG, the electrodes need to be coupled with an active circuit. EEG recordings using active polymer electrodes connected to a clinical EEG system show very promising results: alpha waves can be clearly observed when subjects close their eyes, and correlation and coherence analyses reveal high similarity between dry and gel electrode signals. Moreover, all subjects reported that our polymer electrodes did not cause discomfort. Hence, the polymer-based dry electrodes are promising alternatives to either rigid dry electrodes or conventional gel electrodes. PMID:25513825

  14. Dry Electrode Harness System For Wireless 12-LEAD ECG Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The dry-electrode harness is composed of a variety of components.  The harness interfaces with the human via a commercial-off-the-shelf (COTS) FDA cleared dry...

  15. Electrode positions, transformation coordinates for ECG reconstruction from S-ICD vectors

    Directory of Open Access Journals (Sweden)

    David G. Wilson

    2017-04-01

    Full Text Available The article contains data pertaining to the reconstruction of an 8-lead ECG from 2 subcutaneous implantable cardioverter defibrillator vectors. The location of electrodes on the precordium required for the data collection are detailed; the flow chart for patient selection and exclusion is shown; the summary data of the root mean square error (RMSE (in microvolts and Pearson r for the ECG transformation all cases and the pearson correlation for all the leads measured and reconstructed leads are also shown. Detailed background, methodology and discussion can be found in the linked research article.

  16. Biomedical implementation of liquid metal ink as drawable ECG electrode and skin circuit.

    Directory of Open Access Journals (Sweden)

    Yang Yu

    Full Text Available BACKGROUND: Conventional ways of making bio-electrodes are generally complicated, expensive and unconformable. Here we describe for the first time the method of applying Ga-based liquid metal ink as drawable electrocardiogram (ECG electrodes. Such material owns unique merits in both liquid phase conformability and high electrical conductivity, which provides flexible ways for making electrical circuits on skin surface and a prospective substitution of conventional rigid printed circuit boards (PCBs. METHODS: Fundamental measurements of impedance and polarization voltage of the liquid metal ink were carried out to evaluate its basic electrical properties. Conceptual experiments were performed to draw the alloy as bio-electrodes to acquire ECG signals from both rabbit and human via a wireless module developed on the mobile phone. Further, a typical electrical circuit was drawn in the palm with the ink to demonstrate its potential of implementing more sophisticated skin circuits. RESULTS: With an oxide concentration of 0.34%, the resistivity of the liquid metal ink was measured as 44.1 µΩ·cm with quite low reactance in the form of straight line. Its peak polarization voltage with the physiological saline was detected as -0.73 V. The quality of ECG wave detected from the liquid metal electrodes was found as good as that of conventional electrodes, from both rabbit and human experiments. In addition, the circuit drawn with the liquid metal ink in the palm also runs efficiently. When the loop was switched on, all the light emitting diodes (LEDs were lit and emitted colorful lights. CONCLUSIONS: The liquid metal ink promises unique printable electrical properties as both bio-electrodes and electrical wires. The implemented ECG measurement on biological surface and the successfully run skin circuit demonstrated the conformability and attachment of the liquid metal. The present method is expected to innovate future physiological measurement and

  17. Allergic contact dermatitis to methacrylates in ECG electrode dots.

    Science.gov (United States)

    Lyons, Georgina; Nixon, Rosemary

    2013-02-01

    Acrylates are used widely in acrylic nails, dental restorative materials, paint, varnish, printing ink, adhesives, glue, orthopaedic prostheses, bone cement and diathermy pads. This is the first case of allergic contact dermatitis to methacrylates in electrocardiogram electrode dots reported in the literature.

  18. Non-Invasive Fetal Monitoring: A Maternal Surface ECG Electrode Placement-Based Novel Approach for Optimization of Adaptive Filter Control Parameters Using the LMS and RLS Algorithms.

    Science.gov (United States)

    Martinek, Radek; Kahankova, Radana; Nazeran, Homer; Konecny, Jaromir; Jezewski, Janusz; Janku, Petr; Bilik, Petr; Zidek, Jan; Nedoma, Jan; Fajkus, Marcel

    2017-05-19

    This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.

  19. Minimally spaced electrode positions for multi-functional chest sensors: ECG and respiratory signal estimation

    Directory of Open Access Journals (Sweden)

    Klum Michael

    2016-09-01

    Full Text Available Unobtrusive medical instrumentation is a key in continuous patient monitoring. To increase compliance, multi-functional sensor concepts and measurement sites different from gold-standards are used. In this work, we aim to combine both approaches. We focus on minimally spaced electrode positions with high signal correlations to gold-standards. We present twofold experimental data from six and eleven healthy volunteers and provide chest positions with individual correlations up to 0.83 ± 0.06 for ECG and 0.73 ± 0.28 for the respiratory frequency. Using a performance index, we assess positions with correlations up to 0.77 ± 0.12 for ECG and 0.65 ± 0.35 for the respiratory frequency with 24 mm electrode distance.

  20. An ECG electrode-mounted heart rate, respiratory rhythm, posture and behavior recording system.

    Science.gov (United States)

    Yoshimura, Takahiro; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Ninomiya, Ishio; Morton Caldwell, W

    2004-01-01

    R-R interval, respiration rhythm, posture and behavior recording system has been developed for monitoring a patient's cardiovascular regulatory system in daily life. The recording system consists of three ECG chest electrodes, a variable gain instrumentation amplifier, a dual axis accelerometer, a low power 8-bit single-chip microcomputer and a 1024 KB EEPROM. The complete system is mounted on the chest electrodes. R-R interval and respiration rhythm are calculated by the R waves detected from the ECG. Posture and behavior such as walking and running are detected from the body movements recorded by the accelerometer. The detected data are stored by the EEPROM and, after recording, are downloaded to a desktop computer for analysis.

  1. Time and frequency dependence of disposable ECG electrode-skin impedance.

    Science.gov (United States)

    Olson, W H; Schmincke, D R; Henley, B L

    1979-01-01

    The magnitude and phase of disposable electrode-skin impedance were studied as functions of time, 0-48 hours, and frequency, 1 Hz-1 kHz. For both unabraded and mildly abraded skin, the impedance decreased as a function of time steadily or exponentially with time constants of several hours. Impedance decreased as a function of frequency by factors of 2 to 20 with greatest change at low frequencies. For heavily abraded skin, the impedance decreased slightly and then increased as a function of time especially at low frequencies. Impedance imbalance between pairs of identical electrodes applied in a like manner to the forearm were often greater than k omega, nearly equal to individual electrode-skin impedances, and decreased with time. Electrode impedance imbalance is particularly important because it affects noise levels in ECG recordings.

  2. Time based measurement of the impedance of the skin-electrode interface for dry electrode ECG recording.

    Science.gov (United States)

    Dozio, Roberta; Baba, Adeshina; Assambo, Cedric; Burke, Martin J

    2007-01-01

    This paper reports the measurement of the properties of dry or pasteless conductive electrodes to be used for long-term recording of the human electrocardiogram (ECG). Knowledge of these properties is essential for the correct design of the input stage of associated recording amplifiers. Measurements were made on three commercially available conductive carbon based electrodes at pressures of 5 mmHg and 20 mmHg, located on the lower abdomen of the body on three subjects having different skin types. Parameter values were fitted to a two-time-constant based model of the electrode using data measured over a period of 10s. Values of resistance, ranging from 40kOmega to 1590kOmega and of capacitance ranging from 0.05 microF to 38 microF were obtained for the components, while the values of the time-constants varied from 0.07 s to 3.9s.

  3. Multi-lead ECG electrode array for clinical application of electrocardiographic inverse problem.

    Science.gov (United States)

    Hintermuller, Christoph; Fischer, Gerald; Seger, Michael; Pfeifer, Bernhard; Hanser, Friedrich; Modre, Robert; Tilg, Bernhard

    2004-01-01

    Methods for noninvasive imaging of electric function of the heart might become clinical standard procedure the next years. Thus, the overall procedure has to meet clinical requirements as easy and fast application. In this study we propose a new electrode array which improves the information content in the ECG map, considering clinical constraints such as easy to apply and compatibility with routine leads. A major challenge is the development of an electrode array which yields a high information content even for a large interindividual variation in torso shape. For identifying regions of high information content we introduce the concept of a locally applied virtual electrode array. As a result of our analysis we constructed a new electrode array consisting of two L-shaped regular spaced parts and compared it to the electrode array we use for clinical studies upon activation time imaging. We assume that one side effect caused by the regular shape and spacing of the new array be that the reconstruction of electrodes placed on the patients back is simplified. It may be sufficient to record a few characteristic electrode positions and merge them with a model of the posterior array.

  4. Rank Based Selection of Electrode Positions for a Multi-Lead ECG Electrode Array.

    Science.gov (United States)

    Hintermuller, Christoph; Fischer, Gerald; Seger, Michael; Pfeifer, Bernhard; Modre, Robert; Tilg, Bernhard

    2005-01-01

    Methods for noninvasive imaging of electrical function of the heart seem to become a clinical standard procedure the next years. Thus, the overall procedure has to meet clinical requirements as easy and fast application. In this study we propose a new electrode array meeting clinical requirements such as easy to apply and compatibility with routine leads. Within body surface regions of high sensitivity, identified in a prior, information content based study, the number of required electrodes was optimized using effort-gain plots. These plots were generated by applying a so called type one detector criterion. The optimal array was selected from a set of 12 electrode arrays. Each of them consists of two L-shaped regular spaced parts. The optimal array was found by comparing several layouts and electrode densities to the electrode array we use for clinical studies. It consists of 125 electrodes with a regular spacing between 2cm and 3cm.

  5. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul, E-mail: paul.stolzmann@usz.ch [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetti, Robert; Baumueller, Stephan [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Plass, Andre; Falk, Volkmar [Clinic for Cardiovascular Surgery, University Hospital Zurich (Switzerland); Scheffel, Hans; Feuchtner, Gudrun; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Alkadhi, Hatem [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Leschka, Sebastian [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2011-07-15

    Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates {<=}70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 {+-} 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 {+-} 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates {<=}70 bpm

  6. ECG movement artefacts can be greatly reduced with the aid of a movement absorbing device

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Wandall, Kirsten; Thorball, Jørgen

    2007-01-01

    Accurate ECG signal analysis can be confounded by electric lead, and/or electrode movements varying in origin from, for example, hiccups, tremor or patient restlessness. ECG signals recorded using either a conventional electrode holder or with the aid of an electrode holder capable of absorbing m...

  7. ECG movement artefacts can be greatly reduced with the aid of a movement absorbing device

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Wandall, Kirsten; Thorball, Jørgen

    2007-01-01

    Accurate ECG signal analysis can be confounded by electric lead, and/or electrode movements varying in origin from, for example, hiccups, tremor or patient restlessness. ECG signals recorded using either a conventional electrode holder or with the aid of an electrode holder capable of absorbing...... movement artefacts, were measured on a healthy human subject. Results show a greatly improved stability of the ECG signal recorded using an electrode holder capable of absorbing movement artefacts during periods of lead disturbance, and highlight the movement artefacts that develop when the recording lead...... of a conventional ECG electrode holder is tugged or pulled during theperiod of monitoring. It is concluded that the new design of ECG electrode holder will not only enable clearer signal recordings for clinical assessment, but will reduce the ECG artefacts associated with the transportation of patients, and may...

  8. Employing ensemble empirical mode decomposition for artifact removal: extracting accurate respiration rates from ECG data during ambulatory activity.

    Science.gov (United States)

    Sweeney, Kevin T; Kearney, Damien; Ward, Tomás E; Coyle, Shirley; Diamond, Dermot

    2013-01-01

    Observation of a patient's respiration signal can provide a clinician with the required information necessary to analyse a subject's wellbeing. Due to an increase in population number and the aging population demographic there is an increasing stress being placed on current healthcare systems. There is therefore a requirement for more of the rudimentary patient testing to be performed outside of the hospital environment. However due to the ambulatory nature of these recordings there is also a desire for a reduction in the number of sensors required to perform the required recording in order to be unobtrusive to the wearer, and also to use textile based systems for comfort. The extraction of a proxy for the respiration signal from a recorded electrocardiogram (ECG) signal has therefore received considerable interest from previous researchers. To allow for accurate measurements, currently employed methods rely on the availability of a clean artifact free ECG signal from which to extract the desired respiration signal. However, ambulatory recordings, made outside of the hospital-centric environment, are often corrupted with contaminating artifacts, the most degrading of which are due to subject motion. This paper presents the use of the ensemble empirical mode decomposition (EEMD) algorithm to aid in the extraction of the desired respiration signal. Two separate techniques are examined; 1) Extraction of the respiration signal directly from the noisy ECG 2) Removal of the artifact components relating to the subject movement allowing for the use of currently available respiration signal detection techniques. Results presented illustrate that the two proposed techniques provide significant improvements in the accuracy of the breaths per minute (BPM) metric when compared to the available true respiration signal. The error reduced from ± 5.9 BPM prior to the use of the two techniques to ± 2.9 and ± 3.3 BPM post processing using the EEMD algorithm techniques.

  9. Defibrillation overload recovery performance test system for ECG electrode%心电电极除颤过载恢复性能测试系统

    Institute of Scientific and Technical Information of China (English)

    罗兰英; 田学隆; 周平; 李一言

    2011-01-01

    除颤过载恢复是心电电极的重要电性能,它的优劣直接影响到除颤后心电波形的检测和显示,进而影响对患者的抢救和治疗进程.文中开发了一种心电电极除颤过载性能测试系统,根据最新医药行业标准,基于C8051 F340的硬件系统,通过USB协议进行数据传输,在LabVIEW的软件平台上,实现了对除颤恢复性能指标的检测(包括交流阻抗的测试).系统采用良好的电隔离控制和检测,能精确控制测试过程中的充放电时间.实验结果表明,该系统能准确有效的测试电极对的除颤过载恢复性能,并具有安全、准确、操作简单等优点.%Defibrillation overload recovery performance is one of the most important electrical properties of ECG electrodes, which directly affects the ECG display after the patient is defibrillated, thereby affects the diagnosis and treatment of the patient. A defibrillation overload recovery performance test system for ECG electrodes was developed according to the latest pharmaceutical industry standards and based on the C8051F340 hardware system. With USB protocol data transfer, the detection of defibrillation overload recovery performance parameters (including AC impedance) is implemented on Lab VIEW software platform. The system has good electrical isolation control, which can accurately operate the charging and discharging time during test process automatically. Experiment result shows that this system has good performance, and features safe, accurate and easy to operate.

  10. Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data.

    Science.gov (United States)

    Behar, Joachim; Oster, Julien; Clifford, Gari D

    2014-08-01

    Despite significant advances in adult clinical electrocardiography (ECG) signal processing techniques and the power of digital processors, the analysis of non-invasive foetal ECG (NI-FECG) is still in its infancy. The Physionet/Computing in Cardiology Challenge 2013 addresses some of these limitations by making a set of FECG data publicly available to the scientific community for evaluation of signal processing techniques.The abdominal ECG signals were first preprocessed with a band-pass filter in order to remove higher frequencies and baseline wander. A notch filter to remove power interferences at 50 Hz or 60 Hz was applied if required. The signals were then normalized before applying various source separation techniques to cancel the maternal ECG. These techniques included: template subtraction, principal/independent component analysis, extended Kalman filter and a combination of a subset of these methods (FUSE method). Foetal QRS detection was performed on all residuals using a Pan and Tompkins QRS detector and the residual channel with the smoothest foetal heart rate time series was selected.The FUSE algorithm performed better than all the individual methods on the training data set. On the validation and test sets, the best Challenge scores obtained were E1 = 179.44, E2 = 20.79, E3 = 153.07, E4 = 29.62 and E5 = 4.67 for events 1-5 respectively using the FUSE method. These were the best Challenge scores for E1 and E2 and third and second best Challenge scores for E3, E4 and E5 out of the 53 international teams that entered the Challenge. The results demonstrated that existing standard approaches for foetal heart rate estimation can be improved by fusing estimators together. We provide open source code to enable benchmarking for each of the standard approaches described.

  11. Dry Electrodes for ECG and Pulse Transit Time for Blood Pressure: A Wearable Sensor and Smartphone Communication Approach

    Science.gov (United States)

    Shyamkumar, Prashanth

    Cardiovascular Diseases (CVDs) have been a major cause for deaths in both men and women in United States. Cerebrovascular Diseases like Strokes are known to have origins in CVDs as well. Moreover, nearly 18 Million Americans have a history of myocardial infarction and are currently undergoing cardiac rehabilitation. Consequently, CVDs are the highest costing disease groups and cost more than all types of cancer combined. However, significant cost reduction is possible through the effective use of the vast advances in embedded and pervasive electronic devices for healthcare. These devices can automate and move a significant portion of disease management to the patient's home through cyber connectivity, a concept known as point-of-care (POC) diagnostics and healthcare services. POC can minimize hospital visits and potentially avoid admission altogether with prognostic tools that give advanced notice of any abnormalities or chronic illnesses so that the treatment can be planned in advance. The POC concept requires continuous remote health monitoring. Therefore, the various sensors needed for comprehensive monitoring need to be worn daily and throughout the day. Moreover, true "roaming" capability is necessary so that it does not restrict the user's travel or his/her quotidian activities. Two biomedical signals namely, Electrocardiogram (ECG) and Blood Pressure are important diagnostic tests in assessing the cardiac health of a person. To that end, the research presented in this thesis: First , describes the development of a remote monitoring solution based on Bluetooth(TM), smartphones and cyber infrastructure for cardiac care called e-nanoflex. Second, Sensors for ECG that are compatible with everyday life style namely, (a) dry, gel-less vertically aligned gold nanowire electrodes, (b) dry textile-based conductive sensor electrodes to address the need for this technology to monitor cardiovascular diseases in women are tested with e-nanoflex and discussed. Third, non

  12. Screening For Atrial Fibrillation In The Community Using A Novel ECG Recorder.

    Science.gov (United States)

    Battipaglia Md, Irma; Gilbert BSc, Katrina; Hogarth Md PhD, Andrew J; Tayebjee Md, Muzahir H

    2016-01-01

    Aims: MyDiagnostick (MDK) is a novel portable ECG recorder. We conducted this study to evaluate its role in screening for atrial fibrillation (AF). Methods: The device is a cylindrical rod with metallic electrodes at both ends recording electrocardiogram (ECG) when both electrodes are held. Individuals were requested to hold the device for approximately 15 s, the device was then connected to a laptop (with proprietary software downloaded) and analysed. Anonymised ECGs were stored for further analysis. A total of 855 ECGs were recorded and analysed offline by two arrhythmia specialists assessing ECG quality, in particular the level of noise. A noise score (NS) was devised regarding ECG quality. Results: Seven individuals were found with unknown AF (0,8%). In general ECG quality was good and rhythm diagnosis was certain with total interobserver agreement. Conclusion: The MDK provided a rapid and accurate rhythm analysis and has potential implications in preventing ischaemic cardio-embolic stroke.

  13. Sensitivity- and effort-gain analysis: multilead ECG electrode array selection for activation time imaging.

    Science.gov (United States)

    Hintermüller, Christoph; Seger, Michael; Pfeifer, Bernhard; Fischer, Gerald; Modre, Robert; Tilg, Bernhard

    2006-10-01

    Methods for noninvasive imaging of electric function of the heart might become clinical standard procedure the next years. Thus, the overall procedure has to meet clinical requirements as an easy and fast application. In this paper, we propose a new electrode array which improves the resolution of methods for activation time imaging considering clinical constraints such as easy to apply and compatibility with routine leads. For identifying the body-surface regions where the body surface potential (BSP) is most sensitive to changes in transmembrane potential (TMP), a virtual array method was used to compute local linear dependency (LLD) maps. The virtual array method computes a measure for the LLD in every point on the body surface. The most suitable number and position of the electrodes within the sensitive body surface regions was selected by constructing effort gain (EG) plots. Such a plot depicts the relative attainable rank of the leadfield matrix in relation to the increase in number of electrodes required to build the electrode array. The attainable rank itself was computed by a detector criterion. Such a criterion estimates the maximum number of source space eigenvectors not covered by noise when being mapped to the electrode space by the leadfield matrix and recorded by a detector. From the sensitivity maps, we found that the BSP is most sensitive to changes in TMP on the upper left frontal and dorsal body surface. These sensitive regions are covered best by an electrode array consisting of two L-shaped parts of approximately 30 cm x 30 cm and approximately 20 cm x 20 cm. The EG analysis revealed that the array meeting clinical requirements best and improving the resolution of activation time imaging consists of 125 electrodes with a regular horizontal and vertical spacing of 2-3 cm.

  14. ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation.

    Science.gov (United States)

    Loewe, Axel; Schulze, Walther H W; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar

    2015-01-01

    In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.

  15. ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation

    Directory of Open Access Journals (Sweden)

    Axel Loewe

    2015-01-01

    Full Text Available In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG, however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs. Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.

  16. Cardiopulmonary exercise testing is more accurate than ECG-stress testing in diagnosing myocardial ischemia in subjects with chest pain.

    Science.gov (United States)

    Belardinelli, Romualdo; Lacalaprice, Francesca; Tiano, Luca; Muçai, Andi; Perna, Gian Piero

    2014-06-15

    Cardiopulmonary exercise stress testing (CPET) is used to grade the severity of heart failure and to assess its prognosis. However it is unknown whether CPET may improve diagnostic accuracy of standard ECG stress testing to identify or exclude obstructive coronary artery disease (O-CAD) in patients with chest pain. We prospectively studied 1265 consecutive subjects (55 ± 8 years, 156 women) who were evaluated with ECG stress testing (ET) for chest pain. No one had a documented O-CAD. All patients performed an incremental CPET with ECG recordings on an electronically braked cycle ergometer. Of 1265 patients, 73 had a positive CPET and 1192 had a negative CPET. Seventy-three patients with a positive CPET and 71 patients with a negative CPET agreed to undergo nuclear SPECT imaging and coronary angiography. Follow-up lasted 48 ± 7 months. As compared with ET, sensitivity, specificity, PPV and NPV were all improved significantly (ET: 48%, 55%, 33%, 95%; CPET: 88%, 98%, 73%, 99%, respectively, PVO2>91% of predicted VO2 max and absence of VO2-related signs of myocardial ischemia had no evidence of O-CAD in 100% of cases. Cardiac events occurred in 32 patients with a positive CPET and 8 patients with a negative CPET (log rank 18.2, P<0.0001). In patients with chest pain, CPET showed a better diagnostic and predictive accuracy than traditional ET to detect/exclude myocardial ischemia. Its use should be encouraged among physicians as a first line diagnostic tool in clinical practice. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. [Management of pacemaker patients by bathtub ECG].

    Science.gov (United States)

    Mizukami, H; Togawa, T; Toyoshima, T; Ishijima, M

    1989-01-01

    We evaluated the efficacy of a new method for recording electrocardiogram (ECG) of pacemaker patients in bathtub (bathtub ECG). ECG from the pacemaker implanted patients in the bathtub with tap water was recorded through three silver/silver chloride electrodes (4 x 4 cm) fitted on the inside wall of bathtub. Electric signal was connected to the isolated amplifier and recorded on the strip chart recorder. Contrast to the conventional method for recording standard ECG, bathtub ECG does not require body surface electrodes and is recorded at patients home. Although the amplitude of bathtub ECG was reduced approximately to a quarter of standard ECG, cardiac arrhythmia can be easily interpreted by bathtub ECG. In patients with pacemaker system, the amplitude of the pacing pulse recorded by bathtub ECG was much larger than that of QRS complex recorded by standard ECG. Therefore, we conclude that bathtub ECG would be a suitable method to follow up patients with pacemaker system.

  18. Highly accurate apparatus for electrochemical characterization of the felt electrodes used in redox flow batteries

    Science.gov (United States)

    Park, Jong Ho; Park, Jung Jin; Park, O. Ok; Jin, Chang-Soo; Yang, Jung Hoon

    2016-04-01

    Because of the rise in renewable energy use, the redox flow battery (RFB) has attracted extensive attention as an energy storage system. Thus, many studies have focused on improving the performance of the felt electrodes used in RFBs. However, existing analysis cells are unsuitable for characterizing felt electrodes because of their complex 3-dimensional structure. Analysis is also greatly affected by the measurement conditions, viz. compression ratio, contact area, and contact strength between the felt and current collector. To address the growing need for practical analytical apparatus, we report a new analysis cell for accurate electrochemical characterization of felt electrodes under various conditions, and compare it with previous ones. In this cell, the measurement conditions can be exhaustively controlled with a compression supporter. The cell showed excellent reproducibility in cyclic voltammetry analysis and the results agreed well with actual RFB charge-discharge performance.

  19. Review Paper :Comparative Analysis Of Mother Wavelet Functions With The ECG Signals

    Directory of Open Access Journals (Sweden)

    Kapil Tajane

    2014-01-01

    Full Text Available Electrocardiographic ECG gives the information about electrical activity of the heart captured over time by attaching an external electrode to the skin. Now a days ECG signal is used as a baseline to determine the hearts condition. It is very much essential to detect and process ECG signal accurately. ECG consists of various types of noise such as muscle noise, baseline wander and power line interference etc. To remove such types of noise wavelet transform is used. Mother wavelet is an effective tool for denoising such signals. But selection of proper mother wavelet for the ECG signal is again a challenging task. This paper gives the survey about the wavelet transforms useful for ECG denoising. The different wavelet transform are compared and from that we can decide which one is more suitable.

  20. Variable threshold method for ECG R-peak detection.

    Science.gov (United States)

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  1. Advanced DSP Technique to Remove Baseline Noise from ECG Signal

    Directory of Open Access Journals (Sweden)

    Kanhaiya Kumar

    2012-06-01

    Full Text Available Heart diseases, which are one of the death reasons, are among the several serious problems in this century and as per the latest survey, 60% of the patients die due to Heart problems. In 2011, 10 crores people are suffering from heart diseases in India. Many individuals remain unaware of the symptoms of heart attack or dismiss possible symptoms as being unrelated or not important enough to visit a doctor. Early diagnosis and medical treatment of heart diseases can prevent sudden death of the patient. One of the ways to diagnose heart diseases is to use Electrocardiogram (ECG signals. ECG measures electrical potentials on the body surface via contact electrodes. However, timely and accurate detection of arrhythmias is a complex decision-making process for a cardiologist due to contamination of ECG signals with different frequencies of noise. For reliable interpretation of real-time ECGs, computer based techniques on digital signal processing (DSP of ECG waveform have been reported. ECG signals are non-stationary signals including valuable clinical informations, but frequently these informations are corrupted by noise. Many tools, methods and algorithms based on signal processing theory have been proposed and implemented. In this paper, advanced digital signal processing is carried out in Matlab environment. And the present work basically focuses on implementation and evaluation of methods to remove noise from ECG signal.

  2. Is the pre-hospital ECG after out-of-hospital cardiac arrest accurate for the diagnosis of ST-elevation myocardial infarction?

    DEFF Research Database (Denmark)

    Salam, Idrees; Hassager, Christian; Thomsen, Jakob Hartvig

    2016-01-01

    -hospital ROSC-ECG in predicting ST-elevation myocardial infarction (STEMI). METHOD: ROSC-ECGs of 145 comatose survivors of out-of-hospital cardiac arrest, randomly assigned in the Target Temperature Management trial, were classified according to the current STEMI ECG criteria (third universal definition...... of myocardial infarction). RESULTS: STEs were present in the pre-hospital ROSC-ECG of 78 (54%) patients. A final diagnosis revealed that 69 (48%) patients had STEMI, 31 (21%) patients had non-STEMI and 45 (31%) patients had no myocardial infarction. STE in ROSC-ECGs had a sensitivity of 74% (95% confidence...... intervention was successful in 68% versus 36% (PECG is a suboptimal diagnostic tool to predict STEMI...

  3. Micro EEG/ECG signal’s chopper-stabilization amplifying chip for novel dry-contact electrode

    Science.gov (United States)

    Sun, Jianhui; Wang, Chunxing; Wang, Gongtang; Wang, Jinhui; Hua, Qing; Cheng, Chuanfu; Cai, Xinxia; Yin, Tao; Yu, Yang; Yang, Haigang; Li, Dengwang

    2017-02-01

    Facing the body’s EEG (electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG’s (electrocardiogram, ECG’s waves are real-time displayed with the PC-Labview. The proposed chopper system is a unified EEG/ECG signal’s detection instrument and has a critical real application value. Project supported by the National Natural Science Foundation of China (Nos. 61527815, 31500800, 61501426, 61471342), the National Key Basic Research Plan (No. 2014CB744600), the Beijing Science and Technology Plan (No. Z141100000214002), and the Chinese Academy of Sciences’ Key Project (No. KJZD-EW-L11-2).

  4. [A new ECG electrode concept for the conduction of fetal heart action potentials without penetration of the skin].

    Science.gov (United States)

    Schmidt, S; Langner, K; Rothe, J; Saling, E

    1982-10-01

    Internal cardiotocography is an important method for reliable supervision of the fetus during labor. The main task is the prevention of fetal hypoxia. However, there is a considerable disadvantage as the electrodes used penetrate the fetal skin, creating a possible entry point for organisms. The concept we have developed forms a new way of decreasing the risk of infection during labor by conducting the fetal heart rate potentials without penetrating the skin. The electrode is fixed to the skin of the presenting part by tissue adhesive and electrical contact between the fetal skin and the wire of the electrode is established through using electrolyte fluid.

  5. Technical tips: verification of accurate placement and labeling of 10-10 scalp electrodes and intracranial grid/strip electrodes using documentation tools.

    Science.gov (United States)

    Feravich, Susan M; Keller, Crystal M

    2012-06-01

    In some instances, evaluation of seizure activity may require the addition of 10-10 scalp electrodes or the placement of intracranial grids and strips. At any given time, different technologists may be responsible for placement, addition, and the care of electrodes for the same patient. The presence of extra surface electrodes or extensive coverage of brain with intracranial electrodes increases the risk of incorrect placement and labeling which can cause treatment errors based on inaccurate reading of EEG recordings. Procedures should be put into place with documentation tools to correctly place, label, and hook-up extra 10-10 scalp and intracranial electrodes without errors. By using written processes and documentation tools, staff are more capable of acquiring safe and accurate patient data which increase good patient outcomes. The processes for placement and hook up of 10-10 scalp electrodes and intracranial grid and strip electrodes are different and require separate procedures and documentation tools to ensure accuracy. For 10-10 scalp electrode placement, the use of a 10-10 map, labeled tape, and non-duplicating adjacent electrode colors reduces risk of error Documentation of intracranial grid/strip electrodes includes placement map, list of electrode locations in amplifier and a table of cables and corresponding grid/strips with colors. Accurate hook-up is verified by the technologist and the epileptologist and is documented on recording. With the use of documentation tools and verification procedures, the quality of patient outcomes increases while the potential for recording errors is reduced.

  6. Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms

    Directory of Open Access Journals (Sweden)

    Jeong Su Lee

    2014-08-01

    Full Text Available This study proposes the use of flexible capacitive electrodes for reducing motion artifacts in a wearable electrocardiogram (ECG device. The capacitive electrodes have conductive foam on their surface, a shield, an optimal input bias resistor, and guarding feedback. The electrodes are integrated in a chest belt, and the acquired signals are transmitted wirelessly for ambulatory heart rate monitoring. We experimentally validated the electrode performance with subjects standing and walking on a treadmill at speeds of up to 7 km/h. The results confirmed the highly accurate heart rate detection capacity of the developed system and its feasibility for daily-life ECG monitoring.

  7. ECG (image)

    Science.gov (United States)

    ... electrocardiogram (ECG, EKG) is used extensively in the diagnosis of heart disease, ranging from congenital heart disease in infants to myocardial infarction and myocarditis in adults. Several different types of ...

  8. Sensitivity of CIPS-computed PVC location to measurement errors in ECG electrode position: the need for the 3D Camera

    NARCIS (Netherlands)

    Dam, P.M. van; Gordon, J.P.; Laks, M.

    2014-01-01

    BACKGROUND: The Cardiac Isochrone Positioning System (CIPS) is a non-invasive method able to localize the origins of PVCs, VT and WPW from the 12 lead ECG. The CIPS model integrates a standard 12-lead ECG with an MRI derived model of the heart, lungs, and torso in order to compute the precise electr

  9. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone

    Directory of Open Access Journals (Sweden)

    Fen Miao

    2015-05-01

    Full Text Available Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE, a commercial micro control unit (MCU, a secure digital (SD card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user’s physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone.

  10. [Wireless ECG measurement system with capacitive coupling].

    Science.gov (United States)

    Aleksandrowicz, Adrian; Walter, Marian; Leonhardt, Steffen

    2007-04-01

    This paper describes a measurement system that captures an electrocardiogram (ECG) using capacitively coupled electrodes. The measurement system was integrated into an off-the-shelf office chair (so-called "Aachen SmartChair"). Whereas for classical ECG measurement adhesive is used to attach conductively coupled electrodes to bare skin, the system presented allows ECG measurement through clothing without direct skin contact. Furthermore, a ZigBee communication module was integrated to allow wireless transmission of ECG data to a PC or an ICU patient monitor. For system validation, classical ECG using conductive electrodes was obtained simultaneously. First measurement results, including variations of cloth thickness and material, are presented and some of the system-specific problems of this approach are discussed.

  11. WAVELET ANALYSIS OF ABNORMAL ECGS

    Directory of Open Access Journals (Sweden)

    Vasudha Nannaparaju

    2014-02-01

    Full Text Available Detection of the warning signals by the heart can be diagnosed from ECG. An accurate and reliable diagnosis of ECG is very important however which is cumbersome and at times ambiguous in time domain due to the presence of noise. Study of ECG in wavelet domain using both continuous Wavelet transform (CWT and discrete Wavelet transform (DWT, with well known wavelet as well as a wavelet proposed by the authors for this investigation is found to be useful and yields fairly reliable results. In this study, Wavelet analysis of ECGs of Normal, Hypertensive, Diabetic and Cardiac are carried out. The salient feature of the study is that detection of P and T phases in wavelet domain is feasible which are otherwise feeble or absent in raw ECGs.

  12. Piezoelectric extraction of ECG signal

    Science.gov (United States)

    Ahmad, Mahmoud Al

    2016-11-01

    The monitoring and early detection of abnormalities or variations in the cardiac cycle functionality are very critical practices and have significant impact on the prevention of heart diseases and their associated complications. Currently, in the field of biomedical engineering, there is a growing need for devices capable of measuring and monitoring a wide range of cardiac cycle parameters continuously, effectively and on a real-time basis using easily accessible and reusable probes. In this paper, the revolutionary generation and extraction of the corresponding ECG signal using a piezoelectric transducer as alternative for the ECG will be discussed. The piezoelectric transducer pick up the vibrations from the heart beats and convert them into electrical output signals. To this end, piezoelectric and signal processing techniques were employed to extract the ECG corresponding signal from the piezoelectric output voltage signal. The measured electrode based and the extracted piezoelectric based ECG traces are well corroborated. Their peaks amplitudes and locations are well aligned with each other.

  13. Specificity of elevated intercostal space ECG recording for the type 1 Brugada ECG pattern

    DEFF Research Database (Denmark)

    Holst, Anders G; Tangø, Mogens; Batchvarov, Velislav

    2012-01-01

    Right precordial (V1-3) elevated electrode placement ECG (EEP-ECG) is often used in the diagnosis of Brugada syndrome (BrS). However, the specificity of this has only been studied in smaller studies in Asian populations. We aimed to study this in a larger European population.......Right precordial (V1-3) elevated electrode placement ECG (EEP-ECG) is often used in the diagnosis of Brugada syndrome (BrS). However, the specificity of this has only been studied in smaller studies in Asian populations. We aimed to study this in a larger European population....

  14. Usefulness of multichannel Holter ECG recording in the third intercostal space for detecting type 1 Brugada ECG: comparison with repeated 12-lead ECGs.

    Science.gov (United States)

    Shimeno, Kenji; Takagi, Masahiko; Maeda, Keiko; Tatsumi, Hiroaki; Doi, Atsushi; Yoshiyama, Minoru

    2009-09-01

    Type 1 Brugada ECG is essential for the diagnosis of Brugada syndrome. We aimed to evaluate the usefulness of multichannel Holter ECG recording in the third intercostal space for detecting type 1 Brugada ECG. We enrolled 60 consecutive individuals with type 1 Brugada ECG and 31 individuals with type 2 or 3 Brugada ECG, in the presence or absence of Na+ channel blockers. All individuals underwent 12-lead ECGs recorded in the standard position and the third intercostal space at least 5 times every 3 months (4L-ECGs, 3L-ECGs, respectively) and multichannel Holter ECG. On multichannel Holter ECG, the precordial electrodes were attached at standard positions (4L-Holter) and the third intercostal space (3L-Holter) for leads V1 and V2. Among the 60 individuals, type 1 Brugada ECG in 4L-ECGs, 3L-ECGs, 4L-Holter, and 3L-Holter was detected in 15 (25%), 26 (43.3%), 23 (38.3%), and 33 individuals (55%), respectively, whereas detected in none of the 31 individuals. The documented duration of type 1 Brugada ECG on 3L-Holter was significantly longer than that on 4L-Holter (700 +/- 467 vs 372 +/- 422 min; P = 0.01, 3L-Holter vs 4L-Holter, respectively), and type 1 Brugada ECG was most frequently observed between 6 pm and 12 pm. Neither the presence nor the duration of the appearance of type 1 Brugada ECG differed significantly between symptomatic and asymptomatic individuals. Multichannel Holter ECG recording in the third intercostal space is more sensitive and useful for the diagnosis of type 1 Brugada ECG than repeated 12-lead ECGs or multichannel Holter ECG in the standard position.

  15. ECG Electrocardiogram (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old ECG (Electrocardiogram) KidsHealth > For Parents > ECG (Electrocardiogram) Print A ... whether there is any damage. How Is an ECG Done? There is nothing painful about getting an ...

  16. 一次性心电电极不同更换时间对早产儿的影响%Disposable electrode different time to replace ECG premature influence

    Institute of Scientific and Technical Information of China (English)

    姚君

    2011-01-01

    Objective Discussion the different impacts of replacement times of disposable ECC electrodes on premature babies. Methods 122 cases of premature babies who used 3M-2223 disposable ECG electrodes were randomly divided into 24h (A) group, 48h (B) group, 72h (C) group, 96h (D) Croup. A, B group were 30 cases, 13 cases were female, and C, D group were 31 cases, 15 cases were female. And the ECG electrodes were connected to ECG monitor, observe and monitor skin al lergy and monitoring effects and of babies. Results The rates of positive skin reactions of A, B, C and D group were 10% , 23. 3% , 58. 1% and 74.2% , respectively; The rates of not firmly pasted and instability potential electrodes were 6. 7% , 10% , 12. 9% and 19.4% , respectively; The ratios of the waveform was not clear were 6.7% , 10% , 16. 1% and 19. 4% .respective ly. Conclusion The most reasonable replaced time of the disposable ECG electrodes is 48h, and it will not affect ECG monitoring results and be not easy to result in skin allergies, but also significantly reduces the treatment costs.%目的 探讨一次性心电电极不同更换时间对早产儿的影响.方法 收集早产儿122例,随机将其分为使用3M-2223型一次性心电电极片24h(A)组、48h(B)组、72h(C)组、96h(D)组4组.A、B组均为30例,女性13例,C、D组31例,女性15例.将一次性心电电极片连接心电监护仪,观察早产儿皮肤过敏反应及监测效果.结果 A组、B组、C组和D组皮肤反应为阳性的比率分别为10%、23.3%、58.1%和74.2%,电极粘贴不牢和电极电位不稳定的比率相同,分别为6.7%、10%、12.9%和19.4%,波形不清晰的比率分别为6.7%、10%、16.1%和19.4%.结论 一次性心电电极48h更换最为合理,这样既不会影响心电监测效果,也不易使患者皮肤过敏,同时还大大减少了医疗费用.

  17. A PC-based generator of surface ECG potentials for computer electrocardiograph testing.

    Science.gov (United States)

    Franchi, D; Palagi, G; Bedini, R

    1994-02-01

    The system is composed of an electronic circuit, connected to a PC, whose outputs, starting from ECGs digitally collected by commercial interpretative electrocardiographs, simulate virtual patients' limb and chest electrode potentials. Appropriate software manages the D/A conversion and lines up the original short-term signal in a ring buffer to generate continuous ECG traces. The device also permits the addition of artifacts and/or baseline wanders/shifts on each lead separately. The system has been accurately tested and statistical indexes have been computed to quantify the reproduction accuracy analyzing, in the generated signal, both the errors induced on the fiducial point measurements and the capability to retain the diagnostic significance. The device integrated with an annotated ECG data base constitutes a reliable and powerful system to be used in the quality assurance testing of computer electrocardiographs.

  18. Feedback controlled piezo-motor microdrive for accurate electrode positioning in chronic single unit recording in behaving mice.

    Science.gov (United States)

    Yang, Sungwook; Cho, Jeiwon; Lee, Semin; Park, Kitae; Kim, Jinseok; Huh, Yeowool; Yoon, Eui-Sung; Shin, Hee-Sup

    2011-02-15

    The microdrive is one of the most essential tools for extracellular, single-unit recordings in freely behaving animals to detect and isolate the single-unit activities from brain regions of interest. Due to the increasing number of neuroscience research projects using genetically engineered mice, the demand for effective recording devices in freely moving mice is also increasing. Although manually and automatically operated microdrive devices are available, they are limited in terms of size, weight, accuracy, manipulability, and convenience for single-unit recording in mice. The present study proposed a novel microdrive that employs a small, lightweight piezo-motor and a magnetoresistive (MR) sensor with a closed-loop position feedback control system. The total weight of the device is 1.82 g, which is perfectly suitable for application to mice. Most importantly, the proposed microdrive is capable of monitoring and adjusting electrode movement on-line by integrating a closed-loop feedback control system, which enhances the accuracy of micro-advancement of the electrode by utilizing position feedback. The performance of this newly developed microdrive was extensively evaluated for both mechanical and physiological concerns at both free-loading and various-loading conditions, including agarose gel matrix and then the hippocampus and thalamus of mice. In summary, this proposed microdrive can enhance the quality of recording single unit activities in freely moving mice in terms of the size and weight of the device, the convenience and accuracy of manipulation, and, most of all, in isolating single neurons and recording stability by providing accurate positioning of an electrode.

  19. Accounting for Interference, Scattering, and Electrode Absorption to Make Accurate Internal Quantum Efficiency Measurements in Organic and Other Thin Solar Cells

    KAUST Repository

    Burkhard, George F.

    2010-05-31

    Accurately measuring internal quantum efficiency requires knowledge of absorption in the active layer of a solar cell. The experimentally accessible total absorption includes significant contributions from the electrodes and other nonactive layers. We suggest a straightforward method for calculating the active layer contribution that minimizes error by subtracting optically-modeled electrode absorption from experimentally measured total absorption. (Figure Presented) © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. The Research of ECG Signal Automatic Segmentation Algorithm Based on Fractal Dimension Trajectory

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>In this paper a kind of ECG signal automatic segmentation algorithm based on ECG fractal dimension trajectory is put forward.First,the ECG signal will be analyzed,then constructing the fractal dimension trajectory of ECG signal according to the fractal dimension trajectory constructing algorithm,finally,obtaining ECG signal feature points and ECG automatic segmentation will be realized by the feature of ECG signal fractal dimension trajectory and the feature of ECG frequency domain characteristics.Through Matlab simulation of the algorithm,the results showed that by constructing the ECG fractal dimension trajectory enables ECG location of each component displayed clearly and obtains high success rate of sub-ECG,providing a basis to identify the various components of ECG signal accurately.

  1. Simplified 2D Bidomain Model of Whole Heart Electrical Activity and ECG Generation

    Science.gov (United States)

    Sovilj, Siniša; Magjarević, Ratko; Abed, Amr Al; Lovell, Nigel H.; Dokos, Socrates

    2014-06-01

    The aim of this study was the development of a geometrically simple and highly computationally-efficient two dimensional (2D) biophysical model of whole heart electrical activity, incorporating spontaneous activation of the sinoatrial node (SAN), the specialized conduction system, and realistic surface ECG morphology computed on the torso. The FitzHugh-Nagumo (FHN) equations were incorporated into a bidomain finite element model of cardiac electrical activity, which was comprised of a simplified geometry of the whole heart with the blood cavities, the lungs and the torso as an extracellular volume conductor. To model the ECG, we placed four electrodes on the surface of the torso to simulate three Einthoven leads VI, VII and VIII from the standard 12-lead system. The 2D model was able to reconstruct ECG morphology on the torso from action potentials generated at various regions of the heart, including the sinoatrial node, atria, atrioventricular node, His bundle, bundle branches, Purkinje fibers, and ventricles. Our 2D cardiac model offers a good compromise between computational load and model complexity, and can be used as a first step towards three dimensional (3D) ECG models with more complex, precise and accurate geometry of anatomical structures, to investigate the effect of various cardiac electrophysiological parameters on ECG morphology.

  2. ECG De-noising

    DEFF Research Database (Denmark)

    Kærgaard, Kevin; Jensen, Søren Hjøllund; Puthusserypady, Sadasivan

    2015-01-01

    Electrocardiogram (ECG) is a widely used noninvasive method to study the rhythmic activity of the heart and thereby to detect the abnormalities. However, these signals are often obscured by artifacts from various sources and minimization of these artifacts are of paramount important. This paper...... proposes two adaptive techniques, namely the EEMD-BLMS (Ensemble Empirical Mode Decomposition in conjunction with the Block Least Mean Square algorithm) and DWT-NN (Discrete Wavelet Transform followed by Neural Network) methods in minimizing the artifacts from recorded ECG signals, and compares...... their performance. These methods were first compared on two types of simulated noise corrupted ECG signals: Type-I (desired ECG+noise frequencies outside the ECG frequency band) and Type-II (ECG+noise frequencies both inside and outside the ECG frequency band). Subsequently, they were tested on real ECG recordings...

  3. A method to locate electrode placement.

    Science.gov (United States)

    Brodnick, D

    2000-01-01

    A new method uses redundancy in the 12-lead electrocardiogram (ECG) to determine the angles to all of the electrodes used to record the ECG. No other transducers or signals are needed. The method, a matrix manipulation of the standard 12-lead, would be applicable to all existing ECGs already stored on hospital systems. The invention of this method was originally motivated by the slight differences seen between ECGs acquired by the standard resting electrode placement versus those acquired in a monitoring or exercise placement. An ECG signal is acquired in multiple channels. A covariance matrix is formed. From the eigenvector solution of the matrix, the angles between the eigenvectors and the original signal vectors are determined. The angles calculated for any ECG test are compared to reference angles to determine whether the electrodes are placed in the standard ECG electrode placement, an alternative electrode placement, or an incorrect electrode placement.

  4. A Novel Mobile ECG Telemonitoring System.

    Science.gov (United States)

    Wu, Baoming; Zhuo, Yu; Zhu, Xinjian; Yan, Qingguang; Zhu, Lingyun; Li, Gang

    2005-01-01

    This paper introduces a novel mobile ECG telemonitoring system. By means of CDMA1x (GPSOne) mobile telecommunication network, the system can perform "full time and space" monitoring of human ECG signal, and once the signal of the monitored subject departed from its normal ranges, the hospital ECG monitoring center can further localize his/her geographical position and give rescue in the first time. Another feature of the system is its high anti-interference capability. In order to reduce 50Hz and RF interferences during mobile monitoring, which are usual much serious than conventional hospital monitoring, a new active recording technology was proposed and an active ECG recording electrode was designed. The system has passed the clinical test and used in China.

  5. Adaptive Non-Linear Bayesian Filter for ECG Denoising

    Directory of Open Access Journals (Sweden)

    Mitesh Kumar Sao

    2014-06-01

    Full Text Available The cycles of an electrocardiogram (ECG signal contain three components P-wave, QRS complex and the T-wave. Noise is present in cardiograph as signals being measured in which biological resources (muscle contraction, base line drift, motion noise and environmental resources (power line interference, electrode contact noise, instrumentation noise are normally pollute ECG signal detected at the electrode. Visu-Shrink thresholding and Bayesian thresholding are the two filters based technique on wavelet method which is denoising the PLI noisy ECG signal. So thresholding techniques are applied for the effectiveness of ECG interval and compared the results with the wavelet soft and hard thresholding methods. The outputs are evaluated by calculating the root mean square (RMS, signal to noise ratio (SNR, correlation coefficient (CC and power spectral density (PSD using MATLAB software. The clean ECG signal shows Bayesian thresholding technique is more powerful algorithm for denoising.

  6. Development of a New Type of Mobile ECG Monitoring System%一种新型移动式心电监护系统的研制

    Institute of Scientific and Technical Information of China (English)

    秦海朋; 吴水才; 刘忠英

    2016-01-01

    Objective To design a new mobile ECG monitoring system, which includes a Band-Aid ECG (Electrocardiograph) monitor and an ECG smart phone monitoring APP. The Band-Aid ECG monitor can obtain ECG signal from user’s body in 24 h; the ECG smart phone monitoring APP can obtain ECG data via Bluetooth Low Energy (BLE) from the Band-Aid ECG monitors, and display the ECG wave as well as the heart rate information on its surface in real-time. Methods The low-power Bluetooth chip CC2640 was selected as the main controller unit, coupled with the ECG electrodes and single-lead ECG acquisition circuit to complete the single-lead ECG acquisition. The smart phone APP was developed in the Eclipse IDE, which could obtain ECG data from the Band-Aid ECG monitors via BLE, and draw ECG wave, display heart rate on its screen in real time. The data of ECG was stored as well in the progress. Results The new mobile ECG monitoring system can acquire the ECG signal from user’s body, and transfer it to the smart phone APP via BLE. The smart phone APP can display ECG waveform in real time, and then perform the QRS detection and the calculation of real-time heart rate through the slope threshold method. Conclusion The new mobile ECG monitoring system is convenient to carry and stably operated, and can display ECG wave in real-time, and accurately measure the heart rate, which proves itself with great practical value.%目的:设计一种新型移动式心电监护系统,包括创可贴式心电监护仪和手机心电监护APP。创可贴式心电监护仪可以24 h提取人体的心电信号,手机心电监护APP通过低功耗蓝牙(BLE)从心电监护仪获取心电数据,并在其界面上实时显示心电波形和心率信息。方法以CC2640低功耗蓝牙芯片作为主控芯片,结合心电采集电极和单导心电采集电路,完成单导联心电信号的采集。手机心电监护APP应用Eclipse IDE进行开发,接收心电监护仪通过BLE发送来的心

  7. Electrocardiogram (ECG) pattern modeling and recognition via deterministic learning

    Institute of Scientific and Technical Information of China (English)

    Xunde DONG; Cong WANG; Junmin HU; Shanxing OU

    2014-01-01

    A method for electrocardiogram (ECG) pattern modeling and recognition via deterministic learning theory is presented in this paper. Instead of recognizing ECG signals beat-to-beat, each ECG signal which contains a number of heartbeats is recognized. The method is based entirely on the temporal features (i.e., the dynamics) of ECG patterns, which contains complete information of ECG patterns. A dynamical model is employed to demonstrate the method, which is capable of generating synthetic ECG signals. Based on the dynamical model, the method is shown in the following two phases:the identification (training) phase and the recognition (test) phase. In the identification phase, the dynamics of ECG patterns is accurately modeled and expressed as constant RBF neural weights through the deterministic learning. In the recognition phase, the modeling results are used for ECG pattern recognition. The main feature of the proposed method is that the dynamics of ECG patterns is accurately modeled and is used for ECG pattern recognition. Experimental studies using the Physikalisch-Technische Bundesanstalt (PTB) database are included to demonstrate the effectiveness of the approach.

  8. Online digital filter and QRS detector applicable in low resource ECG monitoring systems.

    Science.gov (United States)

    Tabakov, Serafim; Iliev, Ivo; Krasteva, Vessela

    2008-11-01

    The present work describes fast computation methods for real-time digital filtration and QRS detection, both applicable in autonomous personal ECG systems for long-term monitoring. Since such devices work under considerable artifacts of intensive body and electrode movements, the input filtering should provide high-quality ECG signals supporting the accurate ECG interpretation. In this respect, we propose a combined high-pass and power-line interference rejection filter, introducing the simple principle of averaging of samples with a predefined distance between them. In our implementation (sampling frequency of 250 Hz), we applied averaging over 17 samples distanced by 10 samples (Filter10x17), thus realizing a comb filter with a zero at 50 Hz and high-pass cut-off at 1.1 Hz. Filter10x17 affords very fast filtering procedure at the price of minimal computing resources. Another benefit concerns the small ECG distortions introduced by the filter, providing its powerful application in the preprocessing module of diagnostic systems analyzing the ECG morphology. Filter10x17 does not attenuate the QRS amplitude, or introduce significant ST-segment elevation/depression. The filter output produces a constant error, leading to uniform shifting of the entire P-QRS-T segment toward about 5% of the R-peak amplitude. Tests with standardized ECG signals proved that Filter10x17 is capable to remove very strong baseline wanderings, and to fully suppress 50 Hz interferences. By changing the number of the averaged samples and the distance between them, a filter design with different cut-off and zero frequency could be easily achieved. The real-time QRS detector is designed with simplified computations over single channel, low-resolution ECGs. It relies on simple evaluations of amplitudes and slopes, including history of their mean values estimated over the preceding beats, smart adjustable thresholds, as well as linear logical rules for identification of the R-peaks in real

  9. Capacitive ECG system with direct access to standard leads and body surface potential mapping.

    Science.gov (United States)

    Oehler, Martin; Schilling, Meinhard; Esperer, Hans Dieter

    2009-12-01

    Capacitive electrodes provide the same access to the human electrocardiogram (ECG) as galvanic electrodes, but without the need of direct electrical skin contact and even through layers of clothing. Thus, potential artifacts as a result of poor electrode contact to the skin are avoided and preparation time is significantly reduced. Our system integrates such capacitive electrodes in a 15 sensor array, which is combined with a Tablet PC. This integrated lightweight ECG system (cECG) is easy to place on the chest wall and allows for simultaneous recordings of 14 ECG channels, even if the patient is slightly dressed, e.g., with a t-shirt. In this paper, we present preliminary results on the performance of the cECG regarding the capability of recording body surface potential maps (BSPMs) and obtaining reconstructed standard ECG leads including Einthoven, Goldberger and, with some limitations, Wilson leads. All signals were measured having the subject lie in a supine position and wear a cotton shirt. Signal quality and diagnostic ECG information of the extracted leads are compared with standard ECG measurements. The results show a very close correlation between both types of ECG measurements. It is concluded that the cECG lends itself to rapid screening in clinically unstable patients.

  10. Extract fetal ECG from single-lead abdominal ECG by de-shape short time Fourier transform and nonlocal median

    CERN Document Server

    Li, Su

    2016-01-01

    The multiple fundamental frequency detection problem and the source separation problem from a single-channel signal containing multiple oscillatory components and a nonstationary noise are both challenging tasks. To extract the fetal electrocardiogram (ECG) from a single-lead maternal abdominal ECG, we face both challenges. In this paper, we propose a novel method to extract the fetal ECG signal from the single channel maternal abdominal ECG signal, without any additional measurement. The algorithm is composed of three main ingredients. First, the maternal and fetal heart rates are estimated by the de-shape short time Fourier transform, which is a recently proposed nonlinear time-frequency analysis technique; second, the beat tracking technique is applied to accurately obtain the maternal and fetal R peaks; third, the maternal and fetal ECG waveforms are established by the nonlocal median. The algorithm is evaluated on a simulated fetal ECG signal database ({\\em fecgsyn} database), and tested on two real data...

  11. Development of a portable wireless system for bipolar concentric ECG recording

    Science.gov (United States)

    Prats-Boluda, G.; Ye-Lin, Y.; Bueno Barrachina, J. M.; Senent, E.; Rodriguez de Sanabria, R.; Garcia-Casado, J.

    2015-07-01

    Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization).

  12. [Analysis of pacemaker ECGs].

    Science.gov (United States)

    Israel, Carsten W; Ekosso-Ejangue, Lucy; Sheta, Mohamed-Karim

    2015-09-01

    The key to a successful analysis of a pacemaker electrocardiogram (ECG) is the application of the systematic approach used for any other ECG without a pacemaker: analysis of (1) basic rhythm and rate, (2) QRS axis, (3) PQ, QRS and QT intervals, (4) morphology of P waves, QRS, ST segments and T(U) waves and (5) the presence of arrhythmias. If only the most obvious abnormality of a pacemaker ECG is considered, wrong conclusions can easily be drawn. If a systematic approach is skipped it may be overlooked that e.g. atrial pacing is ineffective, the left ventricle is paced instead of the right ventricle, pacing competes with intrinsic conduction or that the atrioventricular (AV) conduction time is programmed too long. Apart from this analysis, a pacemaker ECG which is not clear should be checked for the presence of arrhythmias (e.g. atrial fibrillation, atrial flutter, junctional escape rhythm and endless loop tachycardia), pacemaker malfunction (e.g. atrial or ventricular undersensing or oversensing, atrial or ventricular loss of capture) and activity of specific pacing algorithms, such as automatic mode switching, rate adaptation, AV delay modifying algorithms, reaction to premature ventricular contractions (PVC), safety window pacing, hysteresis and noise mode. A systematic analysis of the pacemaker ECG almost always allows a probable diagnosis of arrhythmias and malfunctions to be made, which can be confirmed by pacemaker control and can often be corrected at the touch of the right button to the patient's benefit.

  13. Smartphone home monitoring of ECG

    Science.gov (United States)

    Szu, Harold; Hsu, Charles; Moon, Gyu; Landa, Joseph; Nakajima, Hiroshi; Hata, Yutaka

    2012-06-01

    A system of ambulatory, halter, electrocardiography (ECG) monitoring system has already been commercially available for recording and transmitting heartbeats data by the Internet. However, it enjoys the confidence with a reservation and thus a limited market penetration, our system was targeting at aging global villagers having an increasingly biomedical wellness (BMW) homecare needs, not hospital related BMI (biomedical illness). It was designed within SWaP-C (Size, Weight, and Power, Cost) using 3 innovative modules: (i) Smart Electrode (lowpower mixed signal embedded with modern compressive sensing and nanotechnology to improve the electrodes' contact impedance); (ii) Learnable Database (in terms of adaptive wavelets transform QRST feature extraction, Sequential Query Relational database allowing home care monitoring retrievable Aided Target Recognition); (iii) Smartphone (touch screen interface, powerful computation capability, caretaker reporting with GPI, ID, and patient panic button for programmable emergence procedure). It can provide a supplementary home screening system for the post or the pre-diagnosis care at home with a build-in database searchable with the time, the place, and the degree of urgency happened, using in-situ screening.

  14. ECG Signal Analysis and Arrhythmia Detection using Wavelet Transform

    Science.gov (United States)

    Kaur, Inderbir; Rajni, Rajni; Marwaha, Anupma

    2016-12-01

    Electrocardiogram (ECG) is used to record the electrical activity of the heart. The ECG signal being non-stationary in nature, makes the analysis and interpretation of the signal very difficult. Hence accurate analysis of ECG signal with a powerful tool like discrete wavelet transform (DWT) becomes imperative. In this paper, ECG signal is denoised to remove the artifacts and analyzed using Wavelet Transform to detect the QRS complex and arrhythmia. This work is implemented in MATLAB software for MIT/BIH Arrhythmia database and yields the sensitivity of 99.85 %, positive predictivity of 99.92 % and detection error rate of 0.221 % with wavelet transform. It is also inferred that DWT outperforms principle component analysis technique in detection of ECG signal.

  15. ECG signals denoising using wavelet transform and independent component analysis

    Science.gov (United States)

    Liu, Manjin; Hui, Mei; Liu, Ming; Dong, Liquan; Zhao, Zhu; Zhao, Yuejin

    2015-08-01

    A method of two channel exercise electrocardiograms (ECG) signals denoising based on wavelet transform and independent component analysis is proposed in this paper. First of all, two channel exercise ECG signals are acquired. We decompose these two channel ECG signals into eight layers and add up the useful wavelet coefficients separately, getting two channel ECG signals with no baseline drift and other interference components. However, it still contains electrode movement noise, power frequency interference and other interferences. Secondly, we use these two channel ECG signals processed and one channel signal constructed manually to make further process with independent component analysis, getting the separated ECG signal. We can see the residual noises are removed effectively. Finally, comparative experiment is made with two same channel exercise ECG signals processed directly with independent component analysis and the method this paper proposed, which shows the indexes of signal to noise ratio (SNR) increases 21.916 and the root mean square error (MSE) decreases 2.522, proving the method this paper proposed has high reliability.

  16. High-frequency ECG

    Science.gov (United States)

    Tragardh, Elin; Schlegel, Todd T.

    2006-01-01

    The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire

  17. [Fetal ECG monitoring system based on MCU processing].

    Science.gov (United States)

    Hu, Gang; Chen, Wei; Xie, Xicheng; Zhang, Hao

    2004-12-01

    In order to monitor the fetus in labor, the signal characteristic from fetal scalp electrode is researched, An adaptation algorithm and a peak to peak detecting technology are adopted in signal processing, and an adaptation gain control method is used to eliminate disturber from base-line shift. A fetal ECG monitoring system is designed on the basis of C8051F020 MCU.

  18. The programmable ECG simulator.

    Science.gov (United States)

    Caner, Candan; Engin, Mehmet; Engin, Erkan Zeki

    2008-08-01

    This paper reports the design and development of Digital Signal Controller (DSPIC)-based ECG simulator intended to use in testing, calibration and maintenance of electrocardiographic equipment, and to support biomedical engineering students' education. It generates all 12 healthy ECG derivation signals having a profile that varies with heart rate, amplitude, and different noise contamination in a manner which reflects true in vivo conditions. The heart rate can be set at the range of 30 to 120 beats/minute in four steps. The noise and power line interference effects can be set at the range of 0 to 20 dB in three steps. Since standard commercially available electronic components were used to construct the prototype simulator, the proposed design was also relatively inexpensive to produce.

  19. Wireless Smartphone ECG Enables Large-Scale Screening in Diverse Populations.

    Science.gov (United States)

    Haberman, Zachary C; Jahn, Ryan T; Bose, Rupan; Tun, Han; Shinbane, Jerold S; Doshi, Rahul N; Chang, Philip M; Saxon, Leslie A

    2015-05-01

    The ubiquitous presence of internet-connected phones and tablets presents a new opportunity for cost-effective and efficient electrocardiogram (ECG) screening and on-demand diagnosis. Wireless, single-lead real-time ECG monitoring supported by iOS and android devices can be obtained quickly and on-demand. ECGs can be immediately downloaded and reviewed using any internet browser. We compared the standard 12-lead ECG to the smartphone ECG in healthy young adults, elite athletes, and cardiology clinic patients. Accuracy for determining baseline ECG intervals and rate and rhythm was assessed. In 381 participants, 30-second lead I ECG waveforms were obtained using an iPhone case or iPad. Standard 12-lead ECGs were acquired immediately after the smartphone tracing was obtained. De-identified ECGs were interpreted by automated algorithms and adjudicated by two board-certified electrophysiologists. Both smartphone and standard ECGs detected atrial rate and rhythm, AV block, and QRS delay with equal accuracy. Sensitivities ranged from 72% (QRS delay) to 94% (atrial fibrillation). Specificities were all above 94% for both modalities. Smartphone ECG accurately detects baseline intervals, atrial rate, and rhythm and enables screening in diverse populations. Efficient ECG analysis using automated discrimination and an enhanced smartphone application with notification capabilities are features that can be easily incorporated into the acquisition process. © 2015 Wiley Periodicals, Inc.

  20. A cloud computing based 12-lead ECG telemedicine service

    Science.gov (United States)

    2012-01-01

    Background Due to the great variability of 12-lead ECG instruments and medical specialists’ interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists’ decision making support in emergency telecardiology. Methods We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. Results This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. Conclusions This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan. PMID:22838382

  1. Sparse representation-based ECG signal enhancement and QRS detection.

    Science.gov (United States)

    Zhou, Yichao; Hu, Xiyuan; Tang, Zhenmin; Ahn, Andrew C

    2016-12-01

    Electrocardiogram (ECG) signal enhancement and QRS complex detection is a critical preprocessing step for further heart disease analysis and diagnosis. In this paper, we propose a sparse representation-based ECG signal enhancement and QRS complex detection algorithm. Unlike traditional Fourier or wavelet transform-based methods, which use fixed bases, the proposed algorithm models the ECG signal as the superposition of a few inner structures plus additive random noise, where these structures (referred to here as atoms) can be learned from the input signal or a training set. Using these atoms and their properties, we can accurately approximate the original ECG signal and remove the noise and other artifacts such as baseline wandering. Additionally, some of the atoms with larger kurtosis values can be modified and used as an indication function to detect and locate the QRS complexes in the enhanced ECG signals. To demonstrate the robustness and efficacy of the proposed algorithm, we compare it with several state-of-the-art ECG enhancement and QRS detection algorithms using both simulated and real-life ECG recordings.

  2. Capacitive driven-right-leg grounding in Indirect-contact ECG measurement.

    Science.gov (United States)

    Lim, Yong Gyu; Chung, Gih Sung; Park, Kwang Suk

    2010-01-01

    For the reduction of common-mode noise level in Indirect-contact ECG (IDC-ECG) measurement, a driven-right-leg grounding method was applied to the IDC-ECG. Because the IDC-ECG does not require any direct contact between the electrodes and the human skin, it is adequate for un-constraining long-term ECG measurement at home and its various applications are now under development. However, larger 60 Hz noise induced by power line appears in IDC-ECG than in conventional ECG, that is a restriction of IDC-ECG application. In this study, the driven-right-leg ground which has been used in conventional direct-contact ECG, was adapted to the IDC-ECG measurement, by feedback of the inversion of amplified common-mode noise to the body through the conductive textile laid on the chair seat. It was shown that the level of 60Hz power line noise was reduced to about -40 dB when the driven-right-leg gain was 1000.

  3. Wireless and Non-contact ECG Measurement System – the “Aachen SmartChair”

    Directory of Open Access Journals (Sweden)

    A. Aleksandrowicz

    2007-01-01

    Full Text Available This publication describes a measurement system that obtains an electrocardiogram (ECG by capacitively coupled electrodes. Fordemonstration purposes, this measurement system was integrated into an off-the-shelf office chair (so-called “Aachen SmartChair”.Whereas in usual clinical applications adhesive, conductively-coupled electrodes have to be attached to the skin, the described system is able to measure an ECG without direct skin contact through the cloth. A wireless communication module was integrated for transmitting theECG data to a PC or to an ICU patient monitor. For system validation, a classical ECG with conductive electrodes and an oxygensaturation signal (SpO2 were obtained simultaneously. Finally, system-specific problems of the presented device are discussed.

  4. Lifestyle support through efficient ECG acquisition and analysis.

    Science.gov (United States)

    Devlin, Steven; Nugent, Chris; Finlay, Dewar

    2005-01-01

    People are becoming more aware of their health and the lifestyles they live. As people use computers more and more in a wide variety of occupations, they would find it desirable to monitor their lifestyle without having to leave their desk. Through the analysis of the Electrocardiogram (ECG), it is possible to obtain a person's heartrate and diagnose a number of conditions associated with abnormal heart function. To obtain an accurate heartrate, the ECG signals have to be analysed and calculations performed to find occurrences of the QRS complex, a major component of the ECG signal. This research entailed creating the software required to interpret ECG signals recorded from an innovative computer peripheral allowing recordings from the user's forearms as they operate the computer. The user could therefore effortlessly monitor their lifestyle during normal computer usage.

  5. The Combined Effect of Filters in ECG Signals for Pre-Processing

    OpenAIRE

    Isha V. Upganlawar; Harshal Chowhan

    2014-01-01

    The ECG signal is abruptly changing and continuous in nature. The heart disease such as paroxysmal of heart, arrhythmia diagnosing, are related with the intelligent health care decision this ECG signal need to be pre-process accurately for further action on it such as extracting the features, wavelet decomposition, distribution of QRS complexes in ECG recordings and related information such as heart rate and RR interval, classification of the signal by using various classifiers etc. Filters p...

  6. Clinical experience in the application of the tissue pH electrode.

    Science.gov (United States)

    Lichtenegger, W; Burghardt, E

    1978-09-01

    Only after placing the pH electrode through an incision could its point enter deep enough into the tissue. The storage of the pH electrode in a reference buffer considerably improved the stability of the electrode. The ECG electrode is at present the weakest link in the realization of continuous pH measurements. Improvements should be effected mainly with the ECG electrode, the electrode cable and the application instruments.

  7. Brugada ECG patterns in athletes.

    Science.gov (United States)

    Chung, Eugene H

    2015-01-01

    Brugada syndrome is responsible for up to 4% of all sudden cardiac deaths worldwide and up to 20% of sudden cardiac deaths in patients with structurally normal hearts. Heterogeneity of repolarization and depolarization, particularly over the right ventricle and the outflow tract, is responsible for the arrhythmogenic substrate. The coved Type I ECG pattern is considered diagnostic of the syndrome but its prevalence is very low. Distinguishing between a saddle back Type 2 Brugada pattern and one of many "Brugada-like" patterns presents challenges especially in athletes. A number of criteria have been proposed to assess Brugada ECG patterns. Proper precordial ECG lead placement is paramount. This paper reviews Brugada syndrome, Brugada ECG patterns, and recently proposed criteria. Recommendations for evaluating a Brugada ECG pattern are provided.

  8. [Effects of different electrodes on bioelectrical impedance values].

    Science.gov (United States)

    Nakadomo, F; Tanaka, K; Yokoyama, T; Maeda, K

    1990-01-01

    Effects of different electrodes on bioelectrical impedance values measured by the Selco bioelectrical impedance plethysmograph (SIF-881, Japan) were investigated using 8 adult females (age: 35.3 +/- 7.6 yr, Ht: 156.9 +/- 3.8 cm, Wt: 57.1 +/- 9.9 kg, and hydrodensitometrically determined body fat: 29.4 +/- 6.0%). The Lectec MP3000 electrode (Liberty Carton, USA) and the Bipolar electrode (Sanwa, Japan) produced significantly higher impedance values when compared to the Disposable electrode (Adovance, Japan) and the ECG electrode (Nihon Kohden, Japan). The coefficient of variation was significantly lower for the Disposable electrode (0.8%) and the ECG electrode (0.2%) than that for the Lectec MP3000 electrode (2.3%) and the Bipolar electrode (4.9%). In conclusion, the ECG electrode provides higher bioelectrical impedance values with the highest reproducibility in the assessment of human body composition by the bioelectrical impedance plethysmography.

  9. Lyapunov exponents for synchronous 12-lead ECG signals

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The Lyapunov exponents of synchronous 12-lead ECG signals have been investigated for the first time using a multi-sensor (electrode) technique. The results show that the Lyapunov exponents computed from different locations on the body surface are not the same, but have a distribution characteristic for the ECG signals recorded from coronary artery disease (CAD) patients with sinus rhythms and for signals from healthy older people. The maximum Lyapunov exponent L1 of all signals is positive. While all the others are negative, so the ECG signal has chaotic characteristics. With the same leads, L1 of CAD patients is less than that of healthy people, so the CAD patients and healthy people can be classified by L1, L1 therefore has potential values in the diagnosis of heart disease.

  10. Convolutional Neural Networks for patient-specific ECG classification.

    Science.gov (United States)

    Kiranyaz, Serkan; Ince, Turker; Hamila, Ridha; Gabbouj, Moncef

    2015-01-01

    We propose a fast and accurate patient-specific electrocardiogram (ECG) classification and monitoring system using an adaptive implementation of 1D Convolutional Neural Networks (CNNs) that can fuse feature extraction and classification into a unified learner. In this way, a dedicated CNN will be trained for each patient by using relatively small common and patient-specific training data and thus it can also be used to classify long ECG records such as Holter registers in a fast and accurate manner. Alternatively, such a solution can conveniently be used for real-time ECG monitoring and early alert system on a light-weight wearable device. The experimental results demonstrate that the proposed system achieves a superior classification performance for the detection of ventricular ectopic beats (VEB) and supraventricular ectopic beats (SVEB).

  11. The Combined Effect of Filters in ECG Signals for Pre-Processing

    Directory of Open Access Journals (Sweden)

    Isha V. Upganlawar

    2014-05-01

    Full Text Available The ECG signal is abruptly changing and continuous in nature. The heart disease such as paroxysmal of heart, arrhythmia diagnosing, are related with the intelligent health care decision this ECG signal need to be pre-process accurately for further action on it such as extracting the features, wavelet decomposition, distribution of QRS complexes in ECG recordings and related information such as heart rate and RR interval, classification of the signal by using various classifiers etc. Filters plays very important role in analyzing the low frequency components in ECG signal. The biomedical signals are of low frequency, the removal of power line interference and baseline wander is a very important step at the pre-processing stage of ECG. In these paper we deal with the study of Median filtering and FIR (Finite Impulse Responsefiltering of ECG signals under noisy condition

  12. Prevention of ECG Electrodes-induced Skin Injury by 3 M Liquid Dressing for Aged Patients%3M液体敷料预防老年患者心电监护时电极片致皮肤损伤的效果观察

    Institute of Scientific and Technical Information of China (English)

    阳绪容; 吴小玲; 蒋丽; 陈丽; 崔金波

    2014-01-01

    目的:探讨3 M液体敷料预防老年患者使用电极片致皮肤损伤的应用效果。方法选取60例安置心电监护仪的老年患者,进行自身对照研究,根据电极片粘贴位置分常规侧和观察侧。在右锁骨中线与第2肋弓交界处及右肋弓下缘以下部位的区域,按常规方法直接粘贴电极片(常规侧);在左锁骨中线与第2肋弓交界处及左肋弓下缘以下部位粘贴电极片的区域,先喷洒3 M液体敷料,待干后再粘贴电极片(观察侧),两侧均间隔48 h更换1次电极片。观察患者两侧接触性皮炎发生率、揭除电极片时疼痛程度的差异。结果患者观察侧接触性皮炎发生率明显低于常规侧,揭除电极片时疼痛程度明显低于常规侧,差异有统计学意义(P<0.05)。结论3 M液体敷料能有效预防老年患者使用电极片致接触性皮炎的发生,同时能降低揭除电极片时疼痛感,提高患者的舒适度,值得临床推广应用。%Objective To explore the effect of 3 M liquid dressing on the prevention of ECG electrodes-induced skin injury for aged patients. Methods Sixty aged patients with ECG monitoring were included for a self-control study. Conventional side and observation side were distinguished based on paste position of electrodes and 3 M liquid dressing was applied in observation side. The electrode was replaced with an interval of 48h then the incidence of contact dermatitis and the pain when removing the electrode were compared in both groups. Results There were lower incidence of contact dermatitis and less pain when removing the electrode in observation side, which indicated statistical significance (P<0.05). Conclusion 3 M liquid dressing is effective for the prevention of contact dermatitis meanwhile patients experience less pain when removing the electrode, which is worth to be promoted clinically.

  13. ECG by mobile technologies.

    Science.gov (United States)

    Guzik, Przemyslaw; Malik, Marek

    Mobile electrocardiographs consist of three components: a mobile device (e.g. a smartphone), an electrocardiographic device or accessory, and a mobile application. Mobile platforms are small computers with sufficient computational power, good quality display, suitable data storage, and several possibilities of data transmission. Electrocardiographic electrodes and sensors for mobile use utilize unconventional materials, e.g. rubber, e-textile, and inkjet-printed nanoparticle electrodes. Mobile devices can be handheld, worn as vests or T-shirts, or attached to patient's skin as biopatches. Mobile electrocardiographic devices and accessories may additionally record other signals including respiratory rate, activity level, and geolocation. Large-scale clinical studies that utilize electrocardiography are easier to conduct using mobile technologies and the collected data are suitable for "big data" processing. This is expected to reveal phenomena so far inaccessible by standard electrocardiographic techniques.

  14. Accurate and representative decoding of the neural drive to muscles in humans with multi-channel intramuscular thin-film electrodes.

    Science.gov (United States)

    Muceli, Silvia; Poppendieck, Wigand; Negro, Francesco; Yoshida, Ken; Hoffmann, Klaus P; Butler, Jane E; Gandevia, Simon C; Farina, Dario

    2015-09-01

    Intramuscular electrodes developed over the past 80 years can record the concurrent activity of only a few motor units active during a muscle contraction. We designed, produced and tested a novel multi-channel intramuscular wire electrode that allows in vivo concurrent recordings of a substantially greater number of motor units than with conventional methods. The electrode has been extensively tested in deep and superficial human muscles. The performed tests indicate the applicability of the proposed technology in a variety of conditions. The electrode represents an important novel technology that opens new avenues in the study of the neural control of muscles in humans. We describe the design, fabrication and testing of a novel multi-channel thin-film electrode for detection of the output of motoneurones in vivo and in humans, through muscle signals. The structure includes a linear array of 16 detection sites that can sample intramuscular electromyographic activity from the entire muscle cross-section. The structure was tested in two superficial muscles (the abductor digiti minimi (ADM) and the tibialis anterior (TA)) and a deep muscle (the genioglossus (GG)) during contractions at various forces. Moreover, surface electromyogram (EMG) signals were concurrently detected from the TA muscle with a grid of 64 electrodes. Surface and intramuscular signals were decomposed into the constituent motor unit (MU) action potential trains. With the intramuscular electrode, up to 31 MUs were identified from the ADM muscle during an isometric contraction at 15% of the maximal force (MVC) and 50 MUs were identified for a 30% MVC contraction of TA. The new electrode detects different sources from a surface EMG system, as only one MU spike train was found to be common in the decomposition of the intramuscular and surface signals acquired from the TA. The system also allowed access to the GG muscle, which cannot be analysed with surface EMG, with successful identification of MU

  15. Evaluation of a Behind-the-Ear ECG Device for Smartphone Based Integrated Multiple Smart Sensor System in Health Applications

    Directory of Open Access Journals (Sweden)

    Numan Celik

    2016-07-01

    Full Text Available In this paper, we present a wireless Multiple Smart Sensor System (MSSS in conjunction with a smartphone to enable an unobtrusive monitoring of electrocardiogram (ear-lead ECG integrated with multiple sensor system which includes core body temperature and blood oxygen saturation (SpO2 for ambulatory patients. The proposed behind-the-ear device makes the system desirable to measure ECG data: technically less complex, physically attached to non-hair regions, hence more suitable for long term use, and user friendly as no need to undress the top garment. The proposed smart sensor device is similar to the hearing aid device and is wirelessly connected to a smartphone for physiological data transmission and displaying. This device not only gives access to the core temperature and ECG from the ear, but also the device can be controlled (removed and reapplied by the patient at any time, thus increasing the usability of personal healthcare applications. A number of combination ECG electrodes, which are based on the area of the electrode and dry/non-dry nature of the surface of the electrodes are tested at various locations near behind the ear. The best ECG electrode is then chosen based on the Signal-to-Noise Ratio (SNR of the measured ECG signals. These electrodes showed acceptable SNR ratio of ~20 db, which is comparable with existing tradition ECG electrodes. The developed ECG electrode systems is then integrated with commercially available PPG sensor (Amperor pulse oximeter and core body temperature sensor (MLX90614 using a specialized micro controller (Arduino UNO and the results monitored using a newly developed smartphone (android application.

  16. Wearable ECG Based on Impulse-Radio-Type Human Body Communication.

    Science.gov (United States)

    Wang, Jianqing; Fujiwara, Takuya; Kato, Taku; Anzai, Daisuke

    2016-09-01

    Human body communication (HBC) provides a promising physical layer for wireless body area networks (BANs) in healthcare and medical applications, because of its low propagation loss and high security characteristics. In this study, we have developed a wearable electrocardiogram (ECG) which employs impulse radio (IR)-type HBC technology for transmitting vital signals on the human body in a wearable BAN scenario. The HBC-based wearable ECG has two excellent features. First, the wideband performance of the IR scheme contributed to very low radiation power so that the transceiver is easy to satisfy the extremely weak radio laws, which does not need a license. This feature can provide big convenience in the use and spread of the wearable ECG. Second, the realization of common use of sensing and transmitting electrodes based on time sharing and capacitive coupling largely simplified the HBC-based ECG structure and contributed to its miniaturization. To verify the validity of the HBC-based ECG, we evaluated its communication performance and ECG acquisition performance. The measured bit error rate, smaller than 10 (-3) at 1.25 Mb/s, showed a good physical layer communication performance, and the acquired ECG waveform and various heart-rate variability parameters in time and frequency domains exhibited good agreement with a commercially available radio-frequency ECG and a Holter ECG. These results sufficiently showed the validity and feasibility of the HBC-based ECG for healthcare applications. This should be the first time to have realized a real-time ECG transmission by using the HBC technology.

  17. Using an injection signal to reduce motion artifacts in capacitive ECG measurements.

    Science.gov (United States)

    Serteyn, Aline; Vullings, Rik; Meftah, Mohammed; Bergmans, Jan

    2013-01-01

    Capacitive electrodes are a promising alternative to the conventional adhesive ECG electrodes. They provide more comfort to the patient when integrated in everyday objects (e.g. beds or seats) for long-term monitoring. However, the application of such electrodes is limited by their high sensitivity to motion artifacts. Artifacts caused by variation of the coupling capacitance are studied here. An injection signal is proposed to track these variations in real-time. An adaptive filter then estimates the motion artifact and cancels it from the recorded ECG. The amplitude of the motion artifact is reduced in average by 29 dB in simulation and by 20 dB in a lab environment. Our method has the advantages that it is able to reduce motion artifacts occurring in the frequency band of the ECG and that it does not require knowledge about the measurement system.

  18. Adaptive filtering for ECG rejection from surface EMG recordings.

    Science.gov (United States)

    Marque, C; Bisch, C; Dantas, R; Elayoubi, S; Brosse, V; Pérot, C

    2005-06-01

    Surface electromyograms (EMG) of back muscles are often corrupted by electrocardiogram (ECG) signals. This noise in the EMG signals does not allow to appreciate correctly the spectral content of the EMG signals and to follow its evolution during, for example, a fatigue process. Several methods have been proposed to reject the ECG noise from EMG recordings, but seldom taking into account the eventual changes in ECG characteristics during the experiment. In this paper we propose an adaptive filtering algorithm specifically developed for the rejection of the electrocardiogram corrupting surface electromyograms (SEMG). The first step of the study was to choose the ECG electrode position in order to record the ECG with a shape similar to that found in the noised SEMGs. Then, the efficiency of different algorithms were tested on 28 erector spinae SEMG recordings. The best algorithm belongs to the fast recursive least square family (FRLS). More precisely, the best results were obtained with the simplified formulation of a FRLS algorithm. As an application of the adaptive filtering, the paper compares the evolutions of spectral parameters of noised or denoised (after adaptive filtering) surface EMGs recorded on erector spinae muscles during a trunk extension. The fatigue test was analyzed on 16 EMG recordings. After adaptive filtering, mean initial values of energy and of mean power frequency (MPF) were significantly lower and higher respectively. The differences corresponded to the removal of the ECG components. Furthermore, classical fatigue criteria (increase in energy and decrease in MPF values over time during the fatigue test) were better observed on the denoised EMGs. The mean values of the slopes of the energy-time and MPF-time linear relationships differed significantly when established before and after adaptive filtering. These results account for the efficacy of the adaptive filtering method proposed here to denoise electrophysiological signals.

  19. IDENTIFIKASI SINYAL ECG IRAMA MYOCARDIAL ISCHEMIA DENGAN PENDEKATAN FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    Azhar A N

    2009-07-01

    Full Text Available The heart is one of vital organs in human body. Incidence of heart disease can be fatal for the patient. Myocardial ischemia, the disease that is often suffered by the human, is a disease due to clogged heart arteries blood vessels. One of the ways to detect this disease is by reading the graph output of electrocardiogram (ECG signal. ECG signal represents the condition and activity of the heart. Specialized knowledge, accuration and expertise are required to read ECG graph. To help expert or doctor, expert system based on artificial intelligent, such as Fuzzy Logic approach, can be applied to improve diagnostic accuracy and thoroughness. Fuzzy logic can be applied because of it flexibility to understand the linguistic variables used in identifying myocardial ischemia disease.

  20. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Directory of Open Access Journals (Sweden)

    G. Carrault

    2008-09-01

    Full Text Available Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA. The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  1. Portable ECG design and application based on wireless sensor network

    Directory of Open Access Journals (Sweden)

    Gül Fatma TÜRKER

    2016-05-01

    Full Text Available In this study, in order to follow the heart signals of patients that needs to be monitored instantly and continuously without mobility restrictions, a portable electrocardiogram circuit is designed. After performing the detection, upgrading, cleaning and digitizing of ECG signal received from patient via disposable electrodes, ECG signals was performed that transmit to a central node with Wireless Sensor Network (WSN based on ZigBee 802.11.4 standard. Central node is connected to the serial port of a computer. Received data from the central node is processed on computer and continuous flow graph is obtained. The obligation to use wires for tracing patients’ ECG has been removed with this portable system. As it can be seen in this study, thanks to WSN’s property of forming network by itself and its augmentable loop property, the restrain of ECG signals to reach far away distances can be surmounted. The transmission of biological signals with WSN will light on many studies that follow of patients from a distance.

  2. Sleep stage and obstructive apneaic epoch classification using single-lead ECG

    Directory of Open Access Journals (Sweden)

    Yılmaz Bülent

    2010-08-01

    Full Text Available Abstract Background Polysomnography (PSG is used to define physiological sleep and different physiological sleep stages, to assess sleep quality and diagnose many types of sleep disorders such as obstructive sleep apnea. However, PSG requires not only the connection of various sensors and electrodes to the subject but also spending the night in a bed that is different from the subject's own bed. This study is designed to investigate the feasibility of automatic classification of sleep stages and obstructive apneaic epochs using only the features derived from a single-lead electrocardiography (ECG signal. Methods For this purpose, PSG recordings (ECG included were obtained during the night's sleep (mean duration 7 hours of 17 subjects (5 men with ages between 26 and 67. Based on these recordings, sleep experts performed sleep scoring for each subject. This study consisted of the following steps: (1 Visual inspection of ECG data corresponding to each 30-second epoch, and selection of epochs with relatively clean signals, (2 beat-to-beat interval (RR interval computation using an R-peak detection algorithm, (3 feature extraction from RR interval values, and (4 classification of sleep stages (or obstructive apneaic periods using one-versus-rest approach. The features used in the study were the median value, the difference between the 75 and 25 percentile values, and mean absolute deviations of the RR intervals computed for each epoch. The k-nearest-neighbor (kNN, quadratic discriminant analysis (QDA, and support vector machines (SVM methods were used as the classification tools. In the testing procedure 10-fold cross-validation was employed. Results QDA and SVM performed similarly well and significantly better than kNN for both sleep stage and apneaic epoch classification studies. The classification accuracy rates were between 80 and 90% for the stages other than non-rapid-eye-movement stage 2. The accuracies were 60 or 70% for that specific stage

  3. Heart rate detection in low amplitude non-invasive fetal ECG recordings.

    Science.gov (United States)

    Peters, Chris; Vullings, Rik; Bergmans, Jan; Oei, Guid; Wijn, Pieter

    2006-01-01

    Multi-electrode electrical measurements on the maternal abdomen may provide a valuable alternative to standard fetal monitoring. Removal of the maternal ECG from these recordings by means of subtracting a weighted linear combination of segments from preceding maternal ECG complexes, results in fetal ECG traces from which the fetal heart rate can be determined. Unfortunately, these traces often contain too much noise to determine the heart rate by R-peak detection. To overcome this limitation, an algorithm has been developed that calculates the heart rate based on cross-correlation. To validate the algorithm, noise was added to a fetal scalp ECG recording to simulate low amplitude abdominal recordings. Heart rates calculated by the algorithm were compared to the heart rates from the original scalp ECG. For simulated signals with a signal to noise ratio of 2, the coefficient of correlation was 0.99 (pheart rate, multi-electrode electrical measurements on the maternal abdomen now can be used for fetal monitoring in relatively early stages of pregnancy or other situations where ECG amplitudes are low or noise levels are high.

  4. ENOBIO dry electrophysiology electrode; first human trial plus wireless electrode system.

    Science.gov (United States)

    Ruffini, Giulio; Dunne, Stephen; Farres, Esteve; Cester, Ivan; Watts, Paul C P; Silva, S P; Grau, Carles; Fuentemilla, Lluis; Marco-Pallares, Josep; Vandecasteele, Bjorn

    2007-01-01

    This paper presents the results of the first human trials with the ENOBIO electrophysiology electrode prototype plus the initial results of a new wireless prototype with flexible electrodes based on the same platform. The results indicate that a dry active electrode that employs a CNT array as the electrode interface can perform on a par with traditional "wet" electrodes for the recording of EEG, ECG, EOG and EMG. We also demonstrate a new platform combining wireless technology plus flexible electrodes for improved comfort for applications that take advantage of the dry electrode concept.

  5. Accurate Assessment of the Oxygen Reduction Electrocatalytic Activity of Mn/Polypyrrole Nanocomposites Based on Rotating Disk Electrode Measurements, Complemented with Multitechnique Structural Characterizations

    Directory of Open Access Journals (Sweden)

    Patrizia Bocchetta

    2016-01-01

    Full Text Available This paper reports on the quantitative assessment of the oxygen reduction reaction (ORR electrocatalytic activity of electrodeposited Mn/polypyrrole (PPy nanocomposites for alkaline aqueous solutions, based on the Rotating Disk Electrode (RDE method and accompanied by structural characterizations relevant to the establishment of structure-function relationships. The characterization of Mn/PPy films is addressed to the following: (i morphology, as assessed by Field-Emission Scanning Electron Microscopy (FE-SEM and Atomic Force Microscope (AFM; (ii local electrical conductivity, as measured by Scanning Probe Microscopy (SPM; and (iii molecular structure, accessed by Raman Spectroscopy; these data provide the background against which the electrocatalytic activity can be rationalised. For comparison, the properties of Mn/PPy are gauged against those of graphite, PPy, and polycrystalline-Pt (poly-Pt. Due to the literature lack of accepted protocols for precise catalytic activity measurement at poly-Pt electrode in alkaline solution using the RDE methodology, we have also worked on the obtainment of an intralaboratory benchmark by evidencing some of the time-consuming parameters which drastically affect the reliability and repeatability of the measurement.

  6. Non-contact ECG monitoring

    Science.gov (United States)

    Smirnov, Alexey S.; Erlikh, Vadim V.; Kodkin, Vladimir L.; Keller, Andrei V.; Epishev, Vitaly V.

    2016-03-01

    The research is dedicated to non-contact methods of electrocardiography. The authors describe the routine of experimental procedure and suggest the approach to solving the problems which arise at indirect signal recording. The paper presents the results of experiments conducted by the authors, covers the flow charts of ECG recorders and reviews the drawbacks of filtering methods used in foreign equivalents.

  7. ECG changes in epilepsy patients

    DEFF Research Database (Denmark)

    Tigaran, S; Rasmussen, V; Dam, M

    1997-01-01

    To investigate the frequency of ECG abnormalities suggestive of myocardial ischaemia in patients with severe drug resistant epilepsy and without any indication of previous cardiac disease, assuming that these changes may be of significance for the group of epileptic patients with sudden unexpected...

  8. Analysis of ECG Using Filter Bank Approach

    Directory of Open Access Journals (Sweden)

    S. Thulasi Prasad

    2014-01-01

    Full Text Available In recent years scientists and engineers are facing several problems in the biomedical field. However Digital Signal Processing is solving many of those problems easily and effectively. The signal processing of ECG is very useful in detecting selected arrhythmia conditions from a patient’s electrocardiograph (ECG signals. In this paper we performed analysis of noisy ECG by filtering of 50 Hz power line interference using an adaptive LMS notch filter. This is very meaningful in the measurement of biomedical events, particularly when the recorded ECG signal is very weak. The basic ECG has the frequency range from 5 Hz to 100 Hz. It becomes difficult for the Specialist to diagnose the diseases if the artifacts are present in the ECG signal. Methods of noise reduction have decisive influence on performance of all electro-cardio-graphic (ECG signal processing systems. After removing 50/60 Hz powerline interference, the ECG is lowpass filtered in a digital FIR filter. We designed a Filter Bank to separate frequency ranges of ECG signal to enhance the occurrences QRS complexes. Later the positions of R-peaks are identified and shown plotted. The result shows the ECG signal before filtering and after filtering with their frequency spectrums which clearly indicates the reduction of the power line interference in the ECG signal and a filtered ECG with identified R-peaks.

  9. Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy.

    Science.gov (United States)

    Akintola, Abimbola A; van de Pol, Vera; Bimmel, Daniel; Maan, Arie C; van Heemst, Diana

    2016-01-01

    Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt. Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV). Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artifact content of EQ02 data varied widely between (range 1.93-56.45%) and within (range 0.75-9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was -2.8, -1.0, and -0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed at

  10. Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review

    Science.gov (United States)

    Yao, Shanshan; Zhu, Yong

    2016-04-01

    Long-term, continuous, and unsupervised tracking of physiological data is becoming increasingly attractive for health/wellness monitoring and ailment treatment. Nanomaterials have recently attracted extensive attention as building blocks for flexible/stretchable conductors and are thus promising candidates for electrophysiological electrodes. Here we provide a review on nanomaterial-enabled dry electrodes for electrophysiological sensing, focusing on electrocardiography (ECG). The dry electrodes can be classified into contact surface electrodes, contact-penetrating electrodes, and noncontact capacitive electrodes. Different types of electrodes including their corresponding equivalent electrode-skin interface models and the sources of the noise are first introduced, followed by a review on recent developments of dry ECG electrodes based on various nanomaterials, including metallic nanowires, metallic nanoparticles, carbon nanotubes, and graphene. Their fabrication processes and performances in terms of electrode-skin impedance, signal-to-noise ratio, resistance to motion artifacts, skin compatibility, and long-term stability are discussed.

  11. Suppression of baseline wander in the ECG using a bilinearly transformed, null-phase filter.

    Science.gov (United States)

    Pottala, E W; Bailey, J J; Horton, M R; Gradwohl, J R

    1989-01-01

    The purpose of this study was to design and test a bilinearly transformed, null-phase (BLT/NP) filter for removing baseline wander and to compare it with the cubic spline for performance. For this purpose, the ECG data were filtered to remove high-frequency noise and low-frequency baseline wander to form a set of "clean" ECGs. Artificial low-frequency noise mimicking typical baseline wander was constructed from sine and cosine waves at 0.20 and 0.45 Hz and with amplitudes of 400 and 300 microV, respectively, and added to the "clean" ECGs to form the "test" ECGs. The BLT/NP filter and the cubic spline method each were applied to a "test" ECG to form a "restored" ECG. The measure of performance was the root mean square difference (RMSD) between the "restored" ECG and the initial "clean" ECG. RMSD values showed that on the average the BLT/NP filter performed as well as the cubic spline method and has the advantage that accurate determination of the QRS onset is not required.

  12. Assessment of atrial fibrillation ablation outcomes with clinic ECG, monthly 24-h Holter ECG, and twice-daily telemonitoring ECG.

    Science.gov (United States)

    Kimura, Takehiro; Aizawa, Yoshiyasu; Kurata, Naomi; Nakajima, Kazuaki; Kashimura, Shin; Kunitomi, Akira; Nishiyama, Takahiko; Katsumata, Yoshinori; Nishiyama, Nobuhiro; Fukumoto, Kotaro; Tanimoto, Yoko; Fukuda, Keiichi; Takatsuki, Seiji

    2017-03-01

    Differences in the methodologies for evaluating atrial fibrillation (AF) ablation outcomes should be evaluated. In the present study, we compared the AF ablation outcomes among periodic clinic electrocardiography (ECG), 24-h Holter ECG, and telemonitoring ECG to evaluate the differences among these methods. In addition, we evaluated the AF-free survival rate for each method with different durations of the blanking period. A total of 30 AF patients were followed up for 6 months after initial catheter ablation, with clinic ECG on every clinic visit, monthly 24-h Holter ECG, and telemonitoring ECG twice daily and upon symptoms. AF relapse was defined as AF or atrial tachycardia detected with any of the methods. Two patients dropped out of the study, and 28 patients were followed up for 8.8 ± 2.7 months. Patients underwent 3.6 ± 0.8 clinic ECG, 5.1 ± 0.8 Holter ECG, and 273 ± 68 telemonitoring ECG examinations. During the first, second, third, fourth, fifth, and sixth months of follow-up, Holter ECG detected relapses in 11.1, 8.3, 11.5, 15.4, 4.2, and 4.8 % of patients and telemonitoring ECG detected relapses in 32.1, 25.0, 25.0, 17.9, 28.6, and 17.9 % of patients, respectively. When no duration was set for the blanking period, the AF-free survival rate was significantly lower with telemonitoring ECG (46.4 %) than with Holter ECG (78.6 %, P = 0.013) or clinic ECG (85.7 %, P = 0.002). In addition, when the duration of the blanking period was set to 3 months, the AF-free survival rate was significantly lower with telemonitoring ECG than with clinic ECG (92.9 vs. 71.4 %, P = 0.041). The AF ablation outcomes with twice-daily telemonitoring ECG might differ from those with clinic ECG when the duration of the blanking period is 0-3 months. A follow-up based solely on clinic ECG might underestimate AF recurrence.

  13. Designing for reliable textile neonatal ECG monitoring using multi-sensor recordings.

    Science.gov (United States)

    Bouwstra, S; Chen, W; Oetomo, S Bambang; Feijs, L M G; Cluitmans, P J M

    2011-01-01

    When designing an ECG monitoring system embedded with textile electrodes for comfort, it is challenging to ensure reliable monitoring, because textile electrodes suffer from motion artifacts and incidental poor signal quality. For the design of a comfortable monitoring system for prematurely born babies in the Neonatal Intensive Care Unit (NICU), we propose the concepts of 'diversity measurement' and 'context awareness' to improve reliability. Clinical multi-modal sensor data was collected in the NICU with the Smart Jacket connected to a state-of-the-art amplifier. We found that the ECG signals quality varied among sensors and varied over time, and found correlations between ECG signal, acceleration data, and context, which supports the feasibility of the concepts. Our explorative system level approach has lead to design parameters and meta-insights into the role of clinical validation in the design process.

  14. 76 FR 43582 - Cardiovascular Devices; Classification of Electrocardiograph Electrodes

    Science.gov (United States)

    2011-07-21

    ... electrode, intended to acquire and transmit the electrical signal at the body surface to a processor that... electrical signal at the body surface to a processor that produces an electrocardiogram (ECG) or... performance characteristics, which includes documentation on biocompatibility, electrical...

  15. Fetal cardiac time intervals in healthy pregnancies - an observational study by fetal ECG (Monica Healthcare System).

    Science.gov (United States)

    Wacker-Gussmann, Annette; Plankl, Cordula; Sewald, Maria; Schneider, Karl-Theo Maria; Oberhoffer, Renate; Lobmaier, Silvia M

    2017-04-28

    Fetal electrocardiogram (fECG) can detect QRS signals in fetuses from as early as 17 weeks' gestation; however, the technique is limited by the minute size of the fetal signal relative to noise ratio. The aim of this study was to evaluate precise fetal cardiac time intervals (fCTIs) with the help of a newly developed fetal ECG device (Monica Healthcare System). In a prospective manner we included 15-18 healthy fetuses per gestational week from 32 weeks onwards. The small and wearable Monica AN24 monitoring system uses standard ECG electrodes placed on the maternal abdomen to monitor fECG, maternal ECG and uterine electromyogram (EMG). Fetal CTIs were estimated on 1000 averaged fetal heart beats. Detection was deemed successful if there was a global signal loss of less than 30% and an analysis loss of the Monica AN24 signal separation analysis of less than 50%. Fetal CTIs were determined visually by three independent measurements. A total of 149 fECGs were performed. After applying the requirements 117 fECGs remained for CTI analysis. While the onset and termination of P-wave and QRS-complex could be easily identified in most ECG patterns (97% for P-wave, PQ and PR interval and 100% for QRS-complex), the T-wave was detectable in only 41% of the datasets. The CTI results were comparable to other available methods such as fetal magnetocardiography (fMCG). Although limited and preclinical in its use, fECG (Monica Healthcare System) could be an additional useful tool to detect precise fCTIs from 32 weeks' gestational age onwards.

  16. Adaptive spatio-temporal filtering of disturbed ECGs: a multi-channel approach to heartbeat detection in smart clothing.

    Science.gov (United States)

    Wiklund, Urban; Karlsson, Marcus; Ostlund, Nils; Berglin, Lena; Lindecrantz, Kaj; Karlsson, Stefan; Sandsjö, Leif

    2007-06-01

    Intermittent disturbances are common in ECG signals recorded with smart clothing: this is mainly because of displacement of the electrodes over the skin. We evaluated a novel adaptive method for spatio-temporal filtering for heartbeat detection in noisy multi-channel ECGs including short signal interruptions in single channels. Using multi-channel database recordings (12-channel ECGs from 10 healthy subjects), the results showed that multi-channel spatio-temporal filtering outperformed regular independent component analysis. We also recorded seven channels of ECG using a T-shirt with textile electrodes. Ten healthy subjects performed different sequences during a 10-min recording: resting, standing, flexing breast muscles, walking and pushups. Using adaptive multi-channel filtering, the sensitivity and precision was above 97% in nine subjects. Adaptive multi-channel spatio-temporal filtering can be used to detect heartbeats in ECGs with high noise levels. One application is heartbeat detection in noisy ECG recordings obtained by integrated textile electrodes in smart clothing.

  17. Diagnostic accuracy of prospective ECG gated coronary computed tomography on a 256 slices scanner: Daily practice experience

    Directory of Open Access Journals (Sweden)

    Ahmed M. Fareed

    2014-03-01

    Conclusions: In a highly prevalence diseased population, prospective ECG-gated CTCA using 256-slice scanner is highly accurate for detection and quantification of the degree of coronary luminal stenosis in comparison to ICA.

  18. Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording.

    Science.gov (United States)

    Yokus, Murat A; Jur, Jesse S

    2016-02-01

    A flexible and conformable dry electrode design on nonwoven fabrics is examined as a sensing platform for biopotential measurements. Due to limitations of commercial wet electrodes (e.g., shelf life, skin irritation), dry electrodes are investigated as the potential candidates for long-term monitoring of ECG signals. Multilayered dry electrodes are fabricated by screen printing of Ag/AgCl conductive inks on flexible nonwoven fabrics. This study focuses on the investigation of skin-electrode interface, form factor design, electrode body placement of printed dry electrodes for a wearable sensing platform. ECG signals obtained with dry and wet electrodes are comparatively studied as a function of body posture and movement. Experimental results show that skin-electrode impedance is influenced by printed electrode area, skin-electrode interface material, and applied pressure. The printed electrode yields comparable ECG signals to wet electrodes, and the QRS peak amplitude of ECG signal is dependent on printed electrode area and electrode on body spacing. Overall, fabric-based printed dry electrodes present an inexpensive health monitoring platform solution for mobile wearable electronics applications by fulfilling user comfort and wearability.

  19. A novel low-complexity digital filter design for wearable ECG devices.

    Science.gov (United States)

    Asgari, Shadnaz; Mehrnia, Alireza

    2017-01-01

    Wearable and implantable Electrocardiograph (ECG) devices are becoming prevailing tools for continuous real-time personal health monitoring. The ECG signal can be contaminated by various types of noise and artifacts (e.g., powerline interference, baseline wandering) that must be removed or suppressed for accurate ECG signal processing. Limited device size, power consumption and cost are critical issues that need to be carefully considered when designing any portable health monitoring device, including a battery-powered ECG device. This work presents a novel low-complexity noise suppression reconfigurable finite impulse response (FIR) filter structure for wearable ECG and heart monitoring devices. The design relies on a recently introduced optimally-factored FIR filter method. The new filter structure and several of its useful features are presented in detail. We also studied the hardware complexity of the proposed structure and compared it with the state-of-the-art. The results showed that the new ECG filter has a lower hardware complexity relative to the state-of-the-art ECG filters.

  20. Development of a portable Linux-based ECG measurement and monitoring system.

    Science.gov (United States)

    Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng

    2011-08-01

    This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.

  1. A configurable and low-power mixed signal SoC for portable ECG monitoring applications.

    Science.gov (United States)

    Kim, Hyejung; Kim, Sunyoung; Van Helleputte, Nick; Artes, Antonio; Konijnenburg, Mario; Huisken, Jos; Van Hoof, Chris; Yazicioglu, Refet Firat

    2014-04-01

    This paper describes a mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissue-impedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-to-digital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μ W from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly.

  2. ECG Feature Extraction Techniques - A Survey Approach

    CERN Document Server

    Karpagachelvi, S; Sivakumar, M

    2010-01-01

    ECG Feature Extraction plays a significant role in diagnosing most of the cardiac diseases. One cardiac cycle in an ECG signal consists of the P-QRS-T waves. This feature extraction scheme determines the amplitudes and intervals in the ECG signal for subsequent analysis. The amplitudes and intervals value of P-QRS-T segment determines the functioning of heart of every human. Recently, numerous research and techniques have been developed for analyzing the ECG signal. The proposed schemes were mostly based on Fuzzy Logic Methods, Artificial Neural Networks (ANN), Genetic Algorithm (GA), Support Vector Machines (SVM), and other Signal Analysis techniques. All these techniques and algorithms have their advantages and limitations. This proposed paper discusses various techniques and transformations proposed earlier in literature for extracting feature from an ECG signal. In addition this paper also provides a comparative study of various methods proposed by researchers in extracting the feature from ECG signal.

  3. ECG data compression using Jacobi polynomials.

    Science.gov (United States)

    Tchiotsop, Daniel; Wolf, Didier; Louis-Dorr, Valérie; Husson, René

    2007-01-01

    Data compression is a frequent signal processing operation applied to ECG. We present here a method of ECG data compression utilizing Jacobi polynomials. ECG signals are first divided into blocks that match with cardiac cycles before being decomposed in Jacobi polynomials bases. Gauss quadratures mechanism for numerical integration is used to compute Jacobi transforms coefficients. Coefficients of small values are discarded in the reconstruction stage. For experimental purposes, we chose height families of Jacobi polynomials. Various segmentation approaches were considered. We elaborated an efficient strategy to cancel boundary effects. We obtained interesting results compared with ECG compression by wavelet decomposition methods. Some propositions are suggested to improve the results.

  4. An extensive Markov system for ECG exact coding.

    Science.gov (United States)

    Tai, S C

    1995-02-01

    In this paper, an extensive Markov process, which considers both the coding redundancy and the intersample redundancy, is presented to measure the entropy value of an ECG signal more accurately. It utilizes the intersample correlations by predicting the incoming n samples based on the previous m samples which constitute an extensive Markov process state. Theories of the extensive Markov process and conventional n repeated applications of m-th order Markov process are studied first in this paper. After that, they are realized for ECG exact coding. Results show that a better performance can be achieved by our system. The average code length for the extensive Markov system on the second difference signals was 2.512 b/sample, while the average Huffman code length for the second difference signals was 3.326 b/sample.

  5. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    Science.gov (United States)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the

  6. Detection of Cardiac Abnormalities from Multilead ECG using Multiscale Phase Alternation Features.

    Science.gov (United States)

    Tripathy, R K; Dandapat, S

    2016-06-01

    The cardiac activities such as the depolarization and the relaxation of atria and ventricles are observed in electrocardiogram (ECG). The changes in the morphological features of ECG are the symptoms of particular heart pathology. It is a cumbersome task for medical experts to visually identify any subtle changes in the morphological features during 24 hours of ECG recording. Therefore, the automated analysis of ECG signal is a need for accurate detection of cardiac abnormalities. In this paper, a novel method for automated detection of cardiac abnormalities from multilead ECG is proposed. The method uses multiscale phase alternation (PA) features of multilead ECG and two classifiers, k-nearest neighbor (KNN) and fuzzy KNN for classification of bundle branch block (BBB), myocardial infarction (MI), heart muscle defect (HMD) and healthy control (HC). The dual tree complex wavelet transform (DTCWT) is used to decompose the ECG signal of each lead into complex wavelet coefficients at different scales. The phase of the complex wavelet coefficients is computed and the PA values at each wavelet scale are used as features for detection and classification of cardiac abnormalities. A publicly available multilead ECG database (PTB database) is used for testing of the proposed method. The experimental results show that, the proposed multiscale PA features and the fuzzy KNN classifier have better performance for detection of cardiac abnormalities with sensitivity values of 78.12 %, 80.90 % and 94.31 % for BBB, HMD and MI classes. The sensitivity value of proposed method for MI class is compared with the state-of-art techniques from multilead ECG.

  7. [A wireless ECG monitor based on ARM].

    Science.gov (United States)

    Fan, Ai-Hua; Bian, Chun-Hua; Ning, Xin-Bao; He, Ai-Jun; Zhuang, Jian-Jun; Wu, Xu-Hui

    2008-11-01

    This paper presents a novel monitor which uses ARM controller AT91SAM7S64 as its main processor, LCM (Liquid Crystal Display Module) for displaying ECG waves, SD (Secure Digital memory) card for data storage and RF module PTR8000 for radio data transmission. This portable monitor boasts alarm function for abnormality and can provide dynamic ECG monitoring for patients.

  8. Expert knowledge for computerized ECG interpretation

    NARCIS (Netherlands)

    J.A. Kors (Jan)

    1992-01-01

    textabstractIn this study, two main questions are addressed: (1) Can the time consuming and cumbersome development and refinement of (heuristic) ECG classifiers be alleviated, and (2) Is it possible to increase diagnostic performance of ECG computer programs by combining knowledge from multiple sour

  9. A novel algorithm for Bluetooth ECG.

    Science.gov (United States)

    Pandya, Utpal T; Desai, Uday B

    2012-11-01

    In wireless transmission of ECG, data latency will be significant when battery power level and data transmission distance are not maintained. In applications like home monitoring or personalized care, to overcome the joint effect of previous issues of wireless transmission and other ECG measurement noises, a novel filtering strategy is required. Here, a novel algorithm, identified as peak rejection adaptive sampling modified moving average (PRASMMA) algorithm for wireless ECG is introduced. This algorithm first removes error in bit pattern of received data if occurred in wireless transmission and then removes baseline drift. Afterward, a modified moving average is implemented except in the region of each QRS complexes. The algorithm also sets its filtering parameters according to different sampling rate selected for acquisition of signals. To demonstrate the work, a prototyped Bluetooth-based ECG module is used to capture ECG with different sampling rate and in different position of patient. This module transmits ECG wirelessly to Bluetooth-enabled devices where the PRASMMA algorithm is applied on captured ECG. The performance of PRASMMA algorithm is compared with moving average and S-Golay algorithms visually as well as numerically. The results show that the PRASMMA algorithm can significantly improve the ECG reconstruction by efficiently removing the noise and its use can be extended to any parameters where peaks are importance for diagnostic purpose.

  10. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs.

    Science.gov (United States)

    Hodkinson, Emily C; Neijts, Melanie; Sadrieh, Arash; Imtiaz, Mohammad S; Baumert, Mathias; Subbiah, Rajesh N; Hayward, Christopher S; Boomsma, Dorret; Willemsen, Gonneke; Vandenberg, Jamie I; Hill, Adam P; De Geus, Eco

    2016-01-01

    The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters. Holter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak-Tend and Theight were calculated using structural equation modeling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters. Here we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic-environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease.

  11. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs

    Science.gov (United States)

    Hodkinson, Emily C.; Neijts, Melanie; Sadrieh, Arash; Imtiaz, Mohammad S.; Baumert, Mathias; Subbiah, Rajesh N.; Hayward, Christopher S.; Boomsma, Dorret; Willemsen, Gonneke; Vandenberg, Jamie I.; Hill, Adam P.; De Geus, Eco

    2016-01-01

    Introduction: The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters. Methods and Results: Holter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modeling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters. Conclusions: Here we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic—environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease. PMID:27199769

  12. ECG signal denoising via empirical wavelet transform.

    Science.gov (United States)

    Singh, Omkar; Sunkaria, Ramesh Kumar

    2016-12-29

    This paper presents new methods for baseline wander correction and powerline interference reduction in electrocardiogram (ECG) signals using empirical wavelet transform (EWT). During data acquisition of ECG signal, various noise sources such as powerline interference, baseline wander and muscle artifacts contaminate the information bearing ECG signal. For better analysis and interpretation, the ECG signal must be free of noise. In the present work, a new approach is used to filter baseline wander and power line interference from the ECG signal. The technique utilized is the empirical wavelet transform, which is a new method used to compute the building modes of a given signal. Its performance as a filter is compared to the standard linear filters and empirical mode decomposition.The results show that EWT delivers a better performance.

  13. III Lead ECG Pulse Measurement Sensor

    Science.gov (United States)

    Thangaraju, S. K.; Munisamy, K.

    2015-09-01

    Heart rate sensing is very important. Method of measuring heart pulse by using an electrocardiogram (ECG) technique is described. Electrocardiogram is a measurement of the potential difference (the electrical pulse) generated by a cardiac tissue, mainly the heart. This paper also reports the development of a three lead ECG hardware system that would be the basis of developing a more cost efficient, portable and easy to use ECG machine. Einthoven's Three Lead method [1] is used for ECG signal extraction. Using amplifiers such as the instrumentation amplifier AD620BN and the conventional operational amplifier Ua741 that would be used to amplify the ECG signal extracted develop this system. The signal would then be filtered from noise using Butterworth filter techniques to obtain optimum output. Also a right leg guard was implemented as a safety feature to this system. Simulation was carried out for development of the system using P-spice Program.

  14. Ecg Monitoring Using Android Smart App

    Directory of Open Access Journals (Sweden)

    Pooja Pawar

    2016-04-01

    Full Text Available This paper describes a mixed-signal ECG system that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channelelectrode-tissue-impedance (ETI measurement with high signalquality. Design effective and low cost solution for ECG machine. . Wave forms of ECG can be observed on Android smartphones. Its availability and cost is significant and affordable. That makes this system upgradable and effective for every class of people.. Our system is portable so anyone can handle this in a simple way with android based smartphone. It doesn’t cost much. It reduces work, efforts and expenses for patients and their relatives.

  15. A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects.

    Science.gov (United States)

    Lu, G; Yang, F; Taylor, J A; Stein, J F

    2009-01-01

    Measures of heart rate variability (HRV) are widely used to assess autonomic nervous system (ANS) function. The signal from which they are derived requires accurate determination of the interval between successive heartbeats; it can be recorded via electrocardiography (ECG), which is both non-invasive and widely available. However, methodological problems inherent in the recording and analysis of ECG traces have motivated a search for alternatives. Photoplethysmography (PPG) constitutes another means of determining the timing of cardiac cycles via continuous monitoring of changes in blood volume in a portion of the peripheral microvasculature. This technique measures pulse waveforms, which in some instances may prove a practical basis for HRV analysis. We investigated the feasibility of using earlobe PPG to analyse HRV by applying the same analytic process to PPG and ECG recordings made simultaneously. Comparison of 5-minute recordings demonstrated a very high degree of correlation in the temporal and frequency domains and in nonlinear dynamic analyses between HRV measures derived from PPG and ECG. Our results confirm that PPG provides accurate interpulse intervals from which HRV measures can be accurately derived in healthy subjects under ideal conditions, suggesting this technique may prove a practical alternative to ECG for HRV analysis. This finding is of particular relevance to the care of patients suffering from peripheral hyperkinesia or tremor, which make fingertip PPG recording impractical, and following clinical interventions known to introduce electrical artefacts into the electrocardiogram.

  16. Independent component analysis and decision trees for ECG holter recording de-noising.

    Directory of Open Access Journals (Sweden)

    Jakub Kuzilek

    Full Text Available We have developed a method focusing on ECG signal de-noising using Independent component analysis (ICA. This approach combines JADE source separation and binary decision tree for identification and subsequent ECG noise removal. In order to to test the efficiency of this method comparison to standard filtering a wavelet- based de-noising method was used. Freely data available at Physionet medical data storage were evaluated. Evaluation criteria was root mean square error (RMSE between original ECG and filtered data contaminated with artificial noise. Proposed algorithm achieved comparable result in terms of standard noises (power line interference, base line wander, EMG, but noticeably significantly better results were achieved when uncommon noise (electrode cable movement artefact were compared.

  17. Community-Based ECG Monitoring System for Patients with Cardiovascular Diseases.

    Science.gov (United States)

    Lin, Bor-Shyh; Wong, Alice M; Tseng, Kevin C

    2016-04-01

    This study aims to develop a community-based electrocardiogram (ECG) monitoring system for cardiac outpatients to wirelessly detect heart rate, provide personalized healthcare, and enhance interactive social contact because of the prevalence of deaths from cardiovascular disease and the growing problem of aging in the world. The system not only strengthens the performance of the ECG monitoring system but also emphasizes the ergonomic design of wearable devices and user interfaces. In addition, it enables medical professionals to diagnose cardiac symptoms remotely and electronically manage medical reports and suggestions. The experimental result shows high performance of the dry electrode, even in dynamic conditions. The comparison result with different ECG healthcare systems shows the essential factors that the system should possess and the capability of the proposed system. Finally, a user survey was conducted based on the unified theory of acceptance and users of technology (UTAUT) model.

  18. Basic principles of the ECG. The normal ECG

    African Journals Online (AJOL)

    Angel_D

    of the 10 recording electrodes is placed in its correct position, otherwise the .... leads is an upright deflection of variable amplitude and duration (see Figures 5 and 6). Normal intervals ... This means all are done by the same systematic method to remove bias .... www.tripdatabase.com - note the new tick box at the bottom of ...

  19. The ECG and Respiration Monitoring System Based on Android Smartphone%基于Android智能手机的心电与呼吸监测系统

    Institute of Scientific and Technical Information of China (English)

    邱天爽; 马济通; 张彪; 朱勇

    2015-01-01

    In order to monitor the heart and respiration situation in real time, this paper designs a portable system based on Android platform to monitor ECG and respiration signals. The ECG and respiration signals are detected through ECG electrodes. Then the signals are transported into the Android device via Bluetooth for further analysis and display. In the Android device, the collected ECG signals are preprocessed and the QRS complexes are detected with both difference threshold method and local transform method. Then the ECG abnormality may be determined when it happens. At the same time, the respiratory rate is calculated and the apnea condition may be detected. Simulation and real test show that the system can accurately calculate the parameters related to the heart and respiration of human body, and give an effective and reliable monitor for the abnormal on heart and respiration.%针对家庭实时监测心电和呼吸的需求,本文设计了一款基于Android智能手机的便携式心电与呼吸监测系统。系统通过心电电极采集心电和呼吸信号,经蓝牙将采集的信号传输至Android智能手机端进行实时分析、显示和报警。对采集的心电信号进行预处理,用差分阈值法和局域变换法检测QRS波群,并判断是否有心电异常,同时根据呼吸信号计算出呼吸频率并监测呼吸暂停状况。模拟和真人测试表明,本系统能够准确地计算心率、呼吸频率、监测心电异常状况。

  20. Biomedical engineering tasks. [electrode development for electrocardiography and electroencephalography

    Science.gov (United States)

    1972-01-01

    Electrocardiographic and vectorcardiographic bioinstrumentation work centered on the development of a new electrode system harness for Project Skylab. Evaluation of several silver electrode configurations proved superior impedance voltage performance for silver/silver chloride electrodes mounted flush by using a paste adhesive. A portable ECG processor has been designed and a breadboard unit has been built to sample ECG input data at a rate of 500 samples per second for arrhythmia detection. A small real time display driver program has been developed for statistical analysis on selected QPS features. Engineering work on a sleep monitoring cap assembly continued.

  1. Extraction of fetal ECG signal by an improved method using extended Kalman smoother framework from single channel abdominal ECG signal.

    Science.gov (United States)

    Panigrahy, D; Sahu, P K

    2017-02-16

    This paper proposes a five-stage based methodology to extract the fetal electrocardiogram (FECG) from the single channel abdominal ECG using differential evolution (DE) algorithm, extended Kalman smoother (EKS) and adaptive neuro fuzzy inference system (ANFIS) framework. The heart rate of the fetus can easily be detected after estimation of the fetal ECG signal. The abdominal ECG signal contains fetal ECG signal, maternal ECG component, and noise. To estimate the fetal ECG signal from the abdominal ECG signal, removal of the noise and the maternal ECG component presented in it is necessary. The pre-processing stage is used to remove the noise from the abdominal ECG signal. The EKS framework is used to estimate the maternal ECG signal from the abdominal ECG signal. The optimized parameters of the maternal ECG components are required to develop the state and measurement equation of the EKS framework. These optimized maternal ECG parameters are selected by the differential evolution algorithm. The relationship between the maternal ECG signal and the available maternal ECG component in the abdominal ECG signal is nonlinear. To estimate the actual maternal ECG component present in the abdominal ECG signal and also to recognize this nonlinear relationship the ANFIS is used. Inputs to the ANFIS framework are the output of EKS and the pre-processed abdominal ECG signal. The fetal ECG signal is computed by subtracting the output of ANFIS from the pre-processed abdominal ECG signal. Non-invasive fetal ECG database and set A of 2013 physionet/computing in cardiology challenge database (PCDB) are used for validation of the proposed methodology. The proposed methodology shows a sensitivity of 94.21%, accuracy of 90.66%, and positive predictive value of 96.05% from the non-invasive fetal ECG database. The proposed methodology also shows a sensitivity of 91.47%, accuracy of 84.89%, and positive predictive value of 92.18% from the set A of PCDB.

  2. Fetal Electrocardiogram (fECG Gated MRI

    Directory of Open Access Journals (Sweden)

    Martyn N.J. Paley

    2013-08-01

    Full Text Available We have developed a Magnetic Resonance Imaging (MRI-compatible system to enable gating of a scanner to the heartbeat of a foetus for cardiac, umbilical cord flow and other possible imaging applications. We performed radiofrequency safety testing prior to a fetal electrocardiogram (fECG gated imaging study in pregnant volunteers (n = 3. A compact monitoring device with advanced software capable of reliably detecting both the maternal electrocardiogram (mECG and fECG simultaneously was modified by the manufacturer (Monica Healthcare, Nottingham, UK to provide an external TTL trigger signal from the detected fECG which could be used to trigger a standard 1.5 T MR (GE Healthcare, Milwaukee, WI, USA gating system with suitable attenuation. The MR scanner was tested by triggering rapidly during image acquisition at a typical fetal heart rate (123 beats per minute using a simulated fECG waveform fed into the gating system. Gated MR images were also acquired from volunteers who were attending for a repeat fetal Central Nervous System (CNS examination using an additional rapid cardiac imaging sequence triggered from the measured fECG. No adverse safety effects were encountered. This is the first time fECG gating has been used with MRI and opens up a range of new possibilities to study a developing foetus.

  3. Nonlinear filtering in ECG Signal Enhancement

    Directory of Open Access Journals (Sweden)

    N. Siddiah

    2012-02-01

    Full Text Available High resolution ECG signals are needed in measuring cardiac abnormalities analysis. Generally baseline wander is one of the important artifact occurred in ECG signal extraction, this strongly affects the signal quality. In order to facilitate proper diagnosis these artifacts have to be removed. In this paper various non linear, non adaptive filtering techniques are presented for the removal of baseline wander removal from ECG signals. The performance characteristics of various filtering techniques are measured in terms of signal to noise ratio.

  4. Identification of 4th intercostal space using sternal notch to xiphoid length for accurate electrocardiogram lead placement.

    Science.gov (United States)

    Day, Kevin; Oliva, Isabel; Krupinski, Elizabeth; Marcus, Frank

    2015-01-01

    Precordial ECG lead placement is difficult in obese patients with increased chest wall soft tissues due to inaccurate palpation of the intercostal spaces. We investigated whether the length of the sternum (distance between the sternal notch and xiphoid process) can accurately predict the location of the 4th intercostal space, which is the traditional location for V1 lead position. Fifty-five consecutive adult chest computed tomography examinations were reviewed for measurements. The sternal notch to right 4th intercostal space distance was 67% of the sternal notch to xiphoid process length with an overall correlation of r=0.600 (pintercostal space for accurate placement of the precordial electrodes in adults in whom the 4th intercostal space cannot be found by physical exam. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. IMPORTANCE OF 15 LEAD ECG

    Directory of Open Access Journals (Sweden)

    Bhargav

    2014-10-01

    Full Text Available BACKGROUND AND OBJECTIVES: Posterior wall myocardial infarction is not uncommon acute myocardial infarction and has got its own therapeutic and prognostic implications. Management of Posterior wall myocardial infarction differs from inferior wall myocardial infarction alone. The presence of posterior wall myocardial infarction is known to increase the incidence of cardiogenic shock, arrhythmias and conduction blocks in case of myocardial infarction. Hence the present study was taken up to find out the incidence, clinical profile and complications of posterior wall myocardial infarction in a rural hospital using simple non-invasive investigations like 15 lead electrocardiography and echocardiography. METHODS: A prospective study was conducted on 50 patients of inferior wall myocardial infarction out of 228 Acute Myocardial Infarction proved by ECG standard and posterior leads (v7, v8, v9 were taken at the time of admission and repeated as necessary. A detailed case history was taken and a detailed physical examination was done at the time of admission and during follow up. For recording ECG 12 lead (3 standard leads, 3 augmented limb leads, 6 precordial leads machine was used. The recordings were made at 25 mm/ sec. speed and 1mV=10mm. Posterior leads were taken by using 3 precordial leads fixing on the posterior axillary (v7, infrascapular (v8 and paraspinal (v9 regions all in a same line with the 5th ICS anteriorly. RESULTS: Out of 50 cases of inferior wall myocardial infarction (IWMI studied only 13 (26% had ST elevation in posterior leads indicating posterior wall myocardial infarction (PWMI. Our study showed that complications and mortality was higher in patients of IWMI with PWMI compared to IWMI without PWMI. Out of 50 patients 33 (66% were males indicating a male predominance. Syncope was present in 18% of PWMI and 14% in overall IWMI. Palpitation was seen in 53% of PWMI and 21% of IWMI without PWMI. Smoking history was present in 14% of

  6. Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

    Science.gov (United States)

    Schlegel, Todd T.

    2012-01-01

    Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward

  7. E-Bra system for women ECG measurement with GPRS communication, Nanosensor, and motion artifact remove algorithm

    Science.gov (United States)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth S.; Varadan, Vijay K.

    2012-10-01

    CardioVascular Disease(CVD)s lead the sudden cardiac death due to irregular phenomenon of the cardiac signal by the abnormal case of blood vessel and cardiac structure. For last two decades, cardiac disease research for man is under active discussion. As a result, the death rate by cardiac disease in men has been falling gradually compared with relatively increasing the women death rate due to CVD[2]. The main reason of this phenomenon causes the lack a sense of the seriousness to female CVD and different symptom of female CVD compared with the symptoms of male CVD. Usually, because the women CVD accompanies with ordinary symptoms unrecognizing the heart abnormality signal such as unusual fatigue, sleep disturbances, shortness of breath, anxiety, chest discomfort, and indigestion dyspepsia, most women CVD patients do not realize that these symptoms are related to the CVD symptoms. Therefore, periodic ECG signal observation is required for women cardiac disease patients. ElectroCardioGram(ECG) detection, treadmill test/exercise ECG, nuclear scan, coronary angiography, and intracoronary ultrasound are used to diagnose abnormality of heart. Among the medical checkup methods for CVDs checkup, it is very effective method for the diagnosis of cardiac disease and the early detection of heart abnormality to monitor ECG periodically. This paper suggests the effective ECG monitoring system for woman by attaching the system on woman's brassiere by using augmented chest lead attachment method. The suggested system in this paper consists of ECG signal transmission system and a server program to display and analyze the transmitted ECG. The ECG signal transmission system consists of three parts such as ECG physical signal detection part with two electrodes made by gold nanowire structure, data acquisition with AD converter, and data transmission part with GPRS(General Packet Radio Service) communication. Usually, to detect human bio signal, Ag/AgCl or gold cup electrodes are used

  8. Intermittent short ECG recording is more effective than 24-hour Holter ECG in detection of arrhythmias.

    Science.gov (United States)

    Hendrikx, Tijn; Rosenqvist, Mårten; Wester, Per; Sandström, Herbert; Hörnsten, Rolf

    2014-04-01

    Many patients report symptoms of palpitations or dizziness/presyncope. These patients are often referred for 24-hour Holter ECG, although the sensitivity for detecting relevant arrhythmias is comparatively low. Intermittent short ECG recording over a longer time period might be a convenient and more sensitive alternative. The objective of this study is to compare the efficacy of 24-hour Holter ECG with intermittent short ECG recording over four weeks to detect relevant arrhythmias in patients with palpitations or dizziness/presyncope. prospective, observational, cross-sectional study. Clinical Physiology, University Hospital. 108 consecutive patients referred for ambiguous palpitations or dizziness/presyncope. All individuals underwent a 24-hour Holter ECG and additionally registered 30-second handheld ECG (Zenicor EKG® thumb) recordings at home, twice daily and when having cardiac symptoms, during 28 days. Significant arrhythmias: atrial fibrillation (AF), paroxysmal supraventricular tachycardia (PSVT), atrioventricular (AV) block II-III, sinus arrest (SA), wide complex tachycardia (WCT). 95 patients, 42 men and 53 women with a mean age of 54.1 years, completed registrations. Analysis of Holter registrations showed atrial fibrillation (AF) in two patients and atrioventricular (AV) block II in one patient (= 3.2% relevant arrhythmias [95% CI 1.1-8.9]). Intermittent handheld ECG detected nine patients with AF, three with paroxysmal supraventricular tachycardia (PSVT) and one with AV-block-II (= 13.7% relevant arrhythmias [95% CI 8.2-22.0]). There was a significant difference between the two methods in favour of intermittent ECG with regard to the ability to detect relevant arrhythmias (P = 0.0094). With Holter ECG, no symptoms were registered during any of the detected arrhythmias. With intermittent ECG, symptoms were registered during half of the arrhythmia episodes. Intermittent short ECG recording during four weeks is more effective in detecting AF and PSVT in

  9. Comparison of Different ECG Signals on MATLAB

    Directory of Open Access Journals (Sweden)

    Rajan Chaudhary

    2013-03-01

    Full Text Available In this paper we discuss about biomedical engineering and then a brief description of ECG signal. We have generated a new method to compare different arrhythmic heart signals with normal sinus signals at MATLAB. This is making the comparison very easy. ECG is used to measure the rate and regularity of heartbeats, as well as the position and size of the chambers, the existence of any damage to the heart, and the effects of devices or drugs used to regulate the heart, such as a pacemaker. Uttermost ECGs are performed for diagnostic or research purposes on human hearts, but may also be performed on heart of animals, usually for diagnosis of heart abnormalities or research. Result obtained showing that Comparison of Normal (Sinus and Abnormal (arrhythmia ECG signal. Through this method we can compare any type of disordered signal of heart.

  10. Matching a wavelet to ECG signal.

    Science.gov (United States)

    Takla, George F; Nair, Bala G; Loparo, Kenneth A

    2006-01-01

    In this paper we develop an approach to synthesize a wavelet that matches the ECG signal. Matching a wavelet to a signal of interest has potential advantages in extracting signal features with greater accuracy, particularly when the signal is contaminated with noise. The approach that we have taken is based on the theoretical work done by Chapa and Rao. We have applied their technique to a noise-free ECG signal representing one cardiac cycle. Results indicate that a matched wavelet, that was able to capture the broad ECG features, could be obtained. Such a wavelet could be used to extract ECG features such as QRS complexes and P&T waves with greater accuracy.

  11. ECG Signal Feature Selection for Emotion Recognition

    Directory of Open Access Journals (Sweden)

    Lichen Xun

    2013-01-01

    Full Text Available This paper aims to study the selection of features based on ECG in emotion recognition. In the process of features selection, we start from existing feature selection algorithm, and pay special attention to some of the intuitive value on ECG waveform as well. Through the use of ANOVA and heuristic search, we picked out the different features to distinguish joy and pleasure these two emotions, then we combine this with pathological analysis of ECG signals by the view of the medical experts to discuss the logic corresponding relation between ECG waveform and emotion distinguish. Through experiment, using the method in this paper we only picked out five features and reached 92% of accuracy rate in the recognition of joy and pleasure.

  12. ECG acquisition and automated remote processing

    CERN Document Server

    Gupta, Rajarshi; Bera, Jitendranath

    2014-01-01

    The book is focused on the area of remote processing of ECG in the context of telecardiology, an emerging area in the field of Biomedical Engineering Application. Considering the poor infrastructure and inadequate numbers of physicians in rural healthcare clinics in India and other developing nations, telemedicine services assume special importance. Telecardiology, a specialized area of telemedicine, is taken up in this book considering the importance of cardiac diseases, which is prevalent in the population under discussion. The main focus of this book is to discuss different aspects of ECG acquisition, its remote transmission and computerized ECG signal analysis for feature extraction. It also discusses ECG compression and application of standalone embedded systems, to develop a cost effective solution of a telecardiology system.

  13. [Development of dynamic ECG acquisition and recording system: review and prospect].

    Science.gov (United States)

    Li, Suyi; Yang, Meiling; Ding, Mei; Lin, Guangda; Ling, Zhenbao

    2012-02-01

    Dynamic electrocardiography (DCG) or Holter is the best device to detect arrhythmia and can help early detection of some sudden cardiac death risk factors. The acquisition and recording system of the DCG, however, affects the data quality and the patients' comfort directly. This paper reviews the related latest studies, and discusses the importance of new ECG electrode and wireless dynamic monitoring in DCG monitoring field. Moreover, the existed main problems are summarized and classified and the prospects for the development trend are presented.

  14. Classification of ECG Using Chaotic Models

    Directory of Open Access Journals (Sweden)

    Khandakar Mohammad Ishtiak

    2012-09-01

    Full Text Available Chaotic analysis has been shown to be useful in a variety of medical applications, particularly in cardiology. Chaotic parameters have shown potential in the identification of diseases, especially in the analysis of biomedical signals like electrocardiogram (ECG. In this work, underlying chaos in ECG signals has been analyzed using various non-linear techniques. First, the ECG signal is processed through a series of steps to extract the QRS complex. From this extracted feature, bit-to-bit interval (BBI and instantaneous heart rate (IHR have been calculated. Then some nonlinear parameters like standard deviation, and coefficient of variation and nonlinear techniques like central tendency measure (CTM, and phase space portrait have been determined from both the BBI and IHR. Standard database of MIT-BIH is used as the reference data where each ECG record contains 650000 samples. CTM is calculated for both BBI and IHR for each ECG record of the database. A much higher value of CTM for IHR is observed for eleven patients with normal beats with a mean of 0.7737 and SD of 0.0946. On the contrary, the CTM for IHR of eleven patients with abnormal rhythm shows low value with a mean of 0.0833 and SD 0.0748. CTM for BBI of the same eleven normal rhythm records also shows high values with a mean of 0.6172 and SD 0.1472. CTM for BBI of eleven abnormal rhythm records show low values with a mean of 0.0478 and SD 0.0308. Phase space portrait also demonstrates visible attractor with little dispersion for a healthy person’s ECG and a widely dispersed plot in 2-D plane for the ailing person’s ECG. These results indicate that ECG can be classified based on this chaotic modeling which works on the nonlinear dynamics of the system.

  15. Frequency-domain Analysis of ECG Signal

    Institute of Scientific and Technical Information of China (English)

    Tu Chengyuan; Zeng Yanjun; Li Shuxin

    2007-01-01

    A new simple approach to effectively detect QRS-T complexes in ECG curve is described, so as to easily get the P-wave (when AF does not happen)or the f-wave (when AF happens). By means of signal processing techniques such as the power spectrum function, the auto-correlation function and cross-correlation function,two kinds of ECG signal when AF does or does not happen were successively analyzed, showing the evident differences between them.

  16. Semisupervised ECG Ventricular Beat Classification With Novelty Detection Based on Switching Kalman Filters.

    Science.gov (United States)

    Oster, Julien; Behar, Joachim; Sayadi, Omid; Nemati, Shamim; Johnson, Alistair E W; Clifford, Gari D

    2015-09-01

    Automatic processing and accurate diagnosis of pathological electrocardiogram (ECG) signals remains a challenge. As long-term ECG recordings continue to increase in prevalence, driven partly by the ease of remote monitoring technology usage, the need to automate ECG analysis continues to grow. In previous studies, a model-based ECG filtering approach to ECG data from healthy subjects has been applied to facilitate accurate online filtering and analysis of physiological signals. We propose an extension of this approach, which models not only normal and ventricular heartbeats, but also morphologies not previously encountered. A switching Kalman filter approach is introduced to enable the automatic selection of the most likely mode (beat type), while simultaneously filtering the signal using appropriate prior knowledge. Novelty detection is also made possible by incorporating a third mode for the detection of unknown (not previously observed) morphologies, and denoted as X-factor. This new approach is compared to state-of-the-art techniques for the ventricular heartbeat classification in the MIT-BIH arrhythmia and Incart databases. F1 scores of 98.3% and 99.5% were found on each database, respectively, which are superior to other published algorithms' results reported on the same databases. Only 3% of all the beats were discarded as X-factor, and the majority of these beats contained high levels of noise. The proposed technique demonstrates accurate beat classification in the presence of previously unseen (and unlearned) morphologies and noise, and provides an automated method for morphological analysis of arbitrary (unknown) ECG leads.

  17. New Padded Harness for Self-Acquisition of Resting 12-Lead ECGs

    Science.gov (United States)

    Schlegel, T. T.; Rood, A. T.

    2011-01-01

    We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.

  18. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    Science.gov (United States)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. Screening for cardiovascular risk factors is recommended but not always followed in this population. PHASER is a project charged with identifying and prioritizing risk factors in emergency responders. We have deployed an advanced ECG (A-ECG) system developed at NASA for improved sensitivity and specificity in the detection of cardiac risk. METHODS Forty-four professional firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance and laboratory tests for fasting lipid profiles and glucose. Heart rate and conventional 12-lead ECG were obtained at rest and during incremental treadmill exercise testing (XT). In addition, a 5-min resting 12-lead A-ECG was obtained in a subset of firefighters (n=18) and transmitted over a secure networked system to a physician collaborator at NASA for advanced-ECG analysis. This A-ECG system has been proven, using myocardial perfusion and other imaging, to accurately identify a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, non-ischemic cardiomyopathy, and ischemic cardiomyopathy. RESULTS Subjects mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI of 28 (3) kg/square meter. Maximum oxygen uptake (VO2max) was 39 (9) ml/kg/min. This compares with the 45th %ile in healthy reference values and a recommended standard of 42 ml/kg/min for firefighters. The metabolic threshold (VO

  19. Quality assessment of digital annotated ECG data from clinical trials by the FDA ECG Warehouse.

    Science.gov (United States)

    Sarapa, Nenad

    2007-09-01

    The FDA mandates that digital electrocardiograms (ECGs) from 'thorough' QTc trials be submitted into the ECG Warehouse in Health Level 7 extended markup language format with annotated onset and offset points of waveforms. The FDA did not disclose the exact Warehouse metrics and minimal acceptable quality standards. The author describes the Warehouse scoring algorithms and metrics used by FDA, points out ways to improve FDA review and suggests Warehouse benefits for pharmaceutical sponsors. The Warehouse ranks individual ECGs according to their score for each quality metric and produces histogram distributions with Warehouse-specific thresholds that identify ECGs of questionable quality. Automatic Warehouse algorithms assess the quality of QT annotation and duration of manual QT measurement by the central ECG laboratory.

  20. Fetal electrocardiogram (ECG) for fetal monitoring during labour.

    Science.gov (United States)

    Neilson, James P

    2015-12-21

    fewer fetal scalp samples taken during labour (average RR 0.61, 95% CI 0.41 to 0.91; four trials, 9671 babies; high quality evidence) although the findings were heterogeneous and there were no data from the largest trial (from the USA). There were marginally fewer operative vaginal births (RR 0.92, 95% CI 0.86 to 0.99; six trials, 26,446 women); but no obvious difference in the number of babies with low Apgar scores at five minutes or babies requiring neonatal intubation, or babies requiring admission to the special care unit (RR 0.96, 95% CI 0.89 to 1.04, six trials, 26,410 babies; high quality evidence). There was little evidence that monitoring by PR interval analysis conveyed any benefit of any sort. The modest benefits of fewer fetal scalp samplings during labour (in settings in which this procedure is performed) and fewer instrumental vaginal births have to be considered against the disadvantages of needing to use an internal scalp electrode, after membrane rupture, for ECG waveform recordings. We found little strong evidence that ST waveform analysis had an effect on the primary outcome measures in this systematic review.There was a lack of evidence showing that PR interval analysis improved any outcomes; and a larger future trial may possibly demonstrate beneficial effects.There is little information about the value of fetal ECG waveform monitoring in preterm fetuses in labour. Information about long-term development of the babies included in the trials would be valuable.

  1. Real-time QRS detection using integrated variance for ECG gated cardiac MRI

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2016-09-01

    Full Text Available During magnetic resonance imaging (MRI, a patient’s vital signs are required for different purposes. In cardiac MRI (CMR, an electrocardiogram (ECG of the patient is required for triggering the image acquisition process. However, a reliable QRS detection of an ECG signal acquired inside an MRI scanner is a challenging task due to the magnetohydrodynamic (MHD effect which interferes with the ECG. The aim of this work was to develop a reliable QRS detector usable inside the MRI which also fulfills the standards for medical devices (IEC 60601-2-27. Therefore, a novel real-time QRS detector based on integrated variance measurements is presented. The algorithm was trained on ANSI/AAMI EC13 test waveforms and was then applied to two databases with 12-lead ECG signals recorded inside and outside an MRI scanner. Reliable results for both databases were achieved for the ECG signals recorded inside (DBMRI: sensitivity Se = 99.94%, positive predictive value +P = 99.84% and outside (DBInCarT: Se = 99.29%, +P = 99.72% the MRI. Due to the accurate R-peak detection in real-time this can be used for monitoring and triggering in MRI exams.

  2. QRS DETECTION OF ECG - A STATISTICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    I.S. Siva Rao

    2015-03-01

    Full Text Available Electrocardiogram (ECG is a graphical representation generated by heart muscle. ECG plays an important role in diagnosis and monitoring of heart’s condition. The real time analyzer based on filtering, beat recognition, clustering, classification of signal with maximum few seconds delay can be done to recognize the life threatening arrhythmia. ECG signal examines and study of anatomic and physiologic facets of the entire cardiac muscle. The inceptive task for proficient scrutiny is the expulsion of noise. It is attained by the use of wavelet transform analysis. Wavelets yield temporal and spectral information concurrently and offer stretchability with a possibility of wavelet functions of different properties. This paper is concerned with the extraction of QRS complexes of ECG signals using Discrete Wavelet Transform based algorithms aided with MATLAB. By removing the inconsistent wavelet transform coefficient, denoising is done in ECG signal. In continuation, QRS complexes are identified and in which each peak can be utilized to discover the peak of separate waves like P and T with their derivatives. Here we put forth a new combinatory algorithm builded on using Pan-Tompkins' method and multi-wavelet transform.

  3. Telemedicine supported by Augmented Reality: an interactive guide for untrained people in performing an ECG test.

    Science.gov (United States)

    Bifulco, Paolo; Narducci, Fabio; Vertucci, Raffaele; Ambruosi, Pasquale; Cesarelli, Mario; Romano, Maria

    2014-11-21

    In many telemedicine applications, the correct use of medical device at the point of need is essential to provide an appropriate service. Some applications may require untrained people to interact with medical devices and patients: care delivery in transportation, military actions, home care and telemedicine training.Appropriate operation of medical device and correct connection with patient's body are crucial. In these scenarios, tailored applications of Augmented Reality can offer a valid support by guiding untrained people at the point of need. This study aims to explore the feasibility of using Augmented Reality in telemedicine applications, by facilitating an acceptable use of biomedical equipment by any unskilled person. In particular, a prototype system was built in order to estimate how untrained users, with limited or no knowledge, can effectively interact with an ECG device and properly placing ECG electrodes on patient's chest. An Augmented Reality application was built to support untrained users in performing an ECG test. Simple markers attached to the ECG device and onto patient's thorax allow camera calibration. Once objects and their pose in the space are recognized, the video of the current scene is enriched, in real-time, with additional pointers, text boxes and audio that help the untrained operator to perform the appropriate sequence of operations. All the buttons, switches, ports of the ECG device together with the location of precordial leads were coded and indicated. Some user's voice commands were also included to improve usability. Ten untrained volunteers, supported by the augmented reality, were able to carry out a complete ECG test first on a mannequin and then on a real patient in a reasonable time (about 8 minutes on average). Average positioning errors of precordial electrodes resulted less than 3 mm for the mannequin and less than 7 mm for the real patient. These preliminary findings suggest the effectiveness of the developed

  4. PDF-ECG in clinical practice: A model for long-term preservation of digital 12-lead ECG data.

    Science.gov (United States)

    Sassi, Roberto; Bond, Raymond R; Cairns, Andrew; Finlay, Dewar D; Guldenring, Daniel; Libretti, Guido; Isola, Lamberto; Vaglio, Martino; Poeta, Roberto; Campana, Marco; Cuccia, Claudio; Badilini, Fabio

    2017-08-12

    In clinical practice, data archiving of resting 12-lead electrocardiograms (ECGs) is mainly achieved by storing a PDF report in the hospital electronic health record (EHR). When available, digital ECG source data (raw samples) are only retained within the ECG management system. The widespread availability of the ECG source data would undoubtedly permit successive analysis and facilitate longitudinal studies, with both scientific and diagnostic benefits. PDF-ECG is a hybrid archival format which allows to store in the same file both the standard graphical report of an ECG together with its source ECG data (waveforms). Using PDF-ECG as a model to address the challenge of ECG data portability, long-term archiving and documentation, a real-world proof-of-concept test was conducted in a northern Italy hospital. A set of volunteers undertook a basic ECG using routine hospital equipment and the source data captured. Using dedicated web services, PDF-ECG documents were then generated and seamlessly uploaded in the hospital EHR, replacing the standard PDF reports automatically generated at the time of acquisition. Finally, the PDF-ECG files could be successfully retrieved and re-analyzed. Adding PDF-ECG to an existing EHR had a minimal impact on the hospital's workflow, while preserving the ECG digital data. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Robust human identification using ecg: eigenpulse revisited

    Science.gov (United States)

    Jang, Daniel; Wendelken, Suzanne; Irvine, John M.

    2010-04-01

    Biometrics, such as fingerprint, iris scan, and face recognition, offer methods for identifying individuals based on a unique physiological measurement. Recent studies indicate that a person's electrocardiogram (ECG) may also provide a unique biometric signature. Several methods for processing ECG data have appeared in the literature and most approaches rest on an initial detection and segmentation of the heartbeats. Various sources of noise, such as sensor noise, poor sensor placement, or muscle movements, can degrade the ECG signal and introduce errors into the heartbeat segmentation. This paper presents a screening technique for assessing the quality of each segmented heartbeat. Using this technique, a higher quality signal can be extracted to support the identification task. We demonstrate the benefits of this quality screening using a principal component technique known as eigenpulse. The analysis demonstrated the improvement in performance attributable to the quality screening.

  6. A mobile phone-based ecg and heart sound monitoring system - biomed 2011.

    Science.gov (United States)

    Iwamoto, Junichi; Ogawa, Hidekuni; Maki, Hiromichi; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton

    2011-01-01

    We have developed a telemedicine system to monitor a patient’s electrocardiogram (ECG) and heart sounds (PCG) during daily activity. The complete system, consisting of an ECG recorder, an accelerometer and a 2.4 GHz low power mobile phone, is mounted on three chest sensing electrodes. The accelerometer records the PCG produced by closing of the mitral and aortic valves (S1 and S2). The sampled ECG and PCG are stored in the system for two minutes and continuously updated. When a patient feels heart discomfort such as angina or an arrhythmia, he/she pushes the data transmission switch on the system. The ECG and PCG for the next two minutes are stored in the system, and then the system then sends the four minutes of stored data directly to a hospital server computer via the 1.9 GHz low power mobile phone. These data are stored on the server and then downloaded to the physician’s Java configured mobile phone. The physician can then check the patient’s cardiac condition, regardless of patient or physician locations, and then take appropriate actions.

  7. A Mixed Approach Of Automated ECG Analysis

    Science.gov (United States)

    De, A. K.; Das, J.; Majumder, D. Dutta

    1982-11-01

    ECG is one of the non-invasive and risk-free technique for collecting data about the functional state of the heart. However, all these data-processing techniques can be classified into two basically different approaches -- the first and second generation ECG computer program. Not the opposition, but simbiosis of these two approaches will lead to systems with the highest accuracy. In our paper we are going to describe a mixed approach which will show higher accuracy with lesser amount of computational work. Key Words : Primary features, Patients' parameter matrix, Screening, Logical comparison technique, Multivariate statistical analysis, Mixed approach.

  8. Principal Component Analysis in ECG Signal Processing

    Directory of Open Access Journals (Sweden)

    Andreas Bollmann

    2007-01-01

    Full Text Available This paper reviews the current status of principal component analysis in the area of ECG signal processing. The fundamentals of PCA are briefly described and the relationship between PCA and Karhunen-Loève transform is explained. Aspects on PCA related to data with temporal and spatial correlations are considered as adaptive estimation of principal components is. Several ECG applications are reviewed where PCA techniques have been successfully employed, including data compression, ST-T segment analysis for the detection of myocardial ischemia and abnormalities in ventricular repolarization, extraction of atrial fibrillatory waves for detailed characterization of atrial fibrillation, and analysis of body surface potential maps.

  9. Utility of the CORD ECG Database in Evaluating ECG Interpretation by Emergency Medicine Residents

    Directory of Open Access Journals (Sweden)

    Wong, Hubert E

    2002-10-01

    Full Text Available OBJECTIVES: Electrocardiograph (ECG interpretation is a vital component of Emergency Medicine (EM resident education, but few studies have formally examined ECG teaching methods used in residency training. Recently, the Council of EM Residency Directors (CORD developed an Internet database of 395 ECGs that have been extensively peer-reviewed to incorporate all findings and abnormalities. We examined the efficacy of this database in assessing EM residents' skills in ECG interpretation. METHODS: We used the CORD ECG database to evaluate residents at our academic three-year EM residency. Thirteen residents participated, including four first-year, four second-year, and five third-year residents. Twenty ECGs were selected using 14 search criteria representing a broad range of abnormalities, including infarction, rhythm, and conduction abnormalities. Exams were scored based on all abnormalities and findings listed in the teaching points accompanying each ECG. We assigned points to each abnormal finding based on clinical relevance. RESULTS: Out of a total of 183 points in our clinically weighted scoring system, first-year residents scored an average of 99 points (54.1% [9 1- 1191, second-year residents 11 1 points (60.4% [97-1261, and third-year residents 130 points (7 1.0% [94- 1501, p = 0.12. Clinically relevant abnormalities, including anterior and inferior myocardial infarctions, were most frequently diagnosed correctly, while posterior infarction was more frequently missed. Rhythm abnormalities including ventricular and supraventricular tachycardias were most frequently diagnosed correctly, while conduction abnormalities including left bundle branch block and atrioventricular (AV block were more frequently missed. CONCLUSION: The CORD database represents a valuable resource in the assessment and teaching of ECG skills, allowing more precise identification of areas upon which instruction should be further focused or individually tailored. Our

  10. A wearable wireless ECG monitoring system with dynamic transmission power control for long-term homecare.

    Science.gov (United States)

    Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan

    2015-03-01

    This paper presents a wearable wireless ECG monitoring system based on novel 3-Lead electrode placements for long-term homecare. The experiment for novel 3-Lead electrode placements is carried out, and the results show that the distance between limb electrodes can be significantly reduced. Based on the new electrode position, a small size sensor node, which is powered by a rechargeable battery, is designed to detect, amplify, filter and transmit the ECG signals. The coordinator receives the data and sends it to PC. Finally the signals are displayed on the GUI. In order to control the power consumption of sensor node, a dynamic power adjustment method is applied to automatically adjust the transmission power of the sensor node according to the received signal strength indicator (RSSI), which is related to the distance and obstacle between sensor node and coordinator. The system is evaluated when the user, who wears the sensor, is walking and running. A promising performance is achieved even under body motion. The power consumption can be significantly reduced with this dynamic power adjustment method.

  11. ECG-6511故障维修%The troublity repair of ECG-6511

    Institute of Scientific and Technical Information of China (English)

    张燕

    2001-01-01

    @@ 日本光电ECG-6511型心电图机是在ECG-6151型心电图机的基础上设计生产的一种便携式单导心电图机.它操作简单、携带方便,被广泛应用.我院的心电图机,大部分都是ECG-6511型.现把它的几种故障维修经验介绍给大家,以供参考:

  12. Pattern recognition in paediatric ecgs: the hidden secrets to clinical ...

    African Journals Online (AJOL)

    typical ECG patterns commonly found in routine paediatric cardiac examination, ECG .... an anterolateral myocardial infarct pattern. Deep Q waves .... The light, which can penetrate tissue and bone, stimulates cell mitochondria to kick-start a ...

  13. [Implementation of ECG Monitoring System Based on Internet of Things].

    Science.gov (United States)

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  14. Microphonics in biopotential measurements with capacitive electrodes.

    Science.gov (United States)

    Luna-Lozano, Pablo S; Pallas-Areny, Ramon

    2010-01-01

    Biopotential measurements with capacitive electrodes do not need any direct contact between electrode and skin, which saves the time devoted to expose and prepare the contact area when measuring with conductive electrodes. However, mechanical vibrations resulting from physiological functions such as respiration and cardiac contraction can change the capacitance of the electrode and affect the recordings. This transformation of mechanical vibrations into undesired electric signals is termed microphonics. We have evaluated microphonics in capacitive ECG recordings obtained from a dressed subject seated on a common chair with electrodes placed on the front side of the backrest of the chair. Depending on the softness of the backrest, the recordings may be clearly affected by the displacement of the thorax back wall due to the respiration and to the heart's mechanical activity.

  15. Two surgeons and the ECG-a double blind study

    Directory of Open Access Journals (Sweden)

    Ulf Martin Schilling

    2012-01-01

    Conclusions: Abdominal and orthopaedic surgeons provided an answering scheme are able to interprete the ECG and identify both the normal and the ECG showing life-threatening pathology. The hypothesis that surgeons were unable to interprete the ECG must be rejected.

  16. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used...

  17. Common mode noise cancellation for electrically non-contact ECG measurement system on a chair.

    Science.gov (United States)

    Keun Kim, Ko; Kyu Lim, Yong; Suk Park, Kwang

    2005-01-01

    Electrically non-contact ECG measurement system on a chair can be applied to a number of various fields for continuous health monitoring in daily life. However, the body is floated electrically for this system due to the capacitive electrodes and the floated body is very sensitive to the external noises or motion artifacts which affect the measurement system as the common mode noise. In this paper, the Driven-Seat-Ground circuit similar to the Driven-Right-Leg circuit is proposed to reduce the common mode noise. The analysis of this equivalent circuit is performed and the output signal waveforms are compared between with Driven-Seat-Ground and with capacitive ground. As the results, the Driven-Seat-Ground circuit improves significantly the properties of the fully capacitive ECG measurement system as the negative feedback.

  18. Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    Science.gov (United States)

    Sharif, Behzad; Dharmakumar, Rohan; Arsanjani, Reza; Thomson, Louise; Bairey Merz, C Noel; Berman, Daniel S; Li, Debiao

    2014-12-01

    Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preliminary study is to evaluate whether, in the simple case of single-slice two-dimensional imaging, adequate myocardial contrast can be obtained for accurate visualization of hypoperfused territories in the setting of myocardial ischemia. A T1-weighted pulse sequence with continuous golden-angle radial sampling was developed for non-ECG-gated FPP imaging. A sliding-window scheme with no temporal acceleration was used to reconstruct 8 frames/s. Canines were imaged at 3T with and without coronary stenosis using the proposed scheme and a conventional magnetization-prepared ECG-gated FPP method. Our studies showed that the proposed non-ECG-gated method is capable of generating high-resolution (1.7 × 1.7 × 6 mm(3) ) artifact-free FPP images of a single slice at high heart rates (92 ± 21 beats/min), while matching the performance of conventional FPP imaging in terms of hypoperfused-to-normal myocardial contrast-to-noise ratio (proposed: 5.18 ± 0.70, conventional: 4.88 ± 0.43). Furthermore, the detected perfusion defect areas were consistent with the conventional FPP images. Non-ECG-gated FPP imaging using optimized continuous golden-angle radial acquisition achieves desirable image quality (i.e., adequate myocardial contrast, high spatial resolution, and minimal artifacts) in the setting of ischemia. © 2014 Wiley Periodicals, Inc.

  19. A new microcomputer-based ECG analysis system.

    Science.gov (United States)

    Kyle, M C; Klingeman, J D; Conrad, J D; Freis, E D; Pipberger, H V

    1983-09-01

    A new automated ECG system using advances in microprocessor technology and computerized electrocardiography is described. This microcomputer-based system is self-contained and mobile. It acquires both the 12-lead and orthogonal lead (Frank) electrocardiograms and analyzes the latter within minutes. Software includes the program developed in the Veterans Administration which uses advanced statistical classification techniques and a large well-documented patient data base. Diagnostic probabilities are computed using a Bayesian approach. Diagnostic performance has been tested using independent clinical criteria and found to be quite accurate. This system enables the clinician to immediately review the computer's identifications, measurements, and diagnostic classifications and quickly use these results in clinical decision making. Serial comparisons are readily made since all previous recordings are stored on floppy diskettes. The use of microprocessors in this system makes it economically feasible for practicing physicians.

  20. A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses.

    Science.gov (United States)

    Lanata, Antonio; Guidi, Andrea; Baragli, Paolo; Valenza, Gaetano; Scilingo, Enzo Pasquale

    2015-01-01

    This study reports on a novel method to detect and reduce the contribution of movement artifact (MA) in electrocardiogram (ECG) recordings gathered from horses in free movement conditions. We propose a model that integrates cardiovascular and movement information to estimate the MA contribution. Specifically, ECG and physical activity are continuously acquired from seven horses through a wearable system. Such a system employs completely integrated textile electrodes to monitor ECG and is also equipped with a triaxial accelerometer for movement monitoring. In the literature, the most used technique to remove movement artifacts, when noise bandwidth overlaps the primary source bandwidth, is the adaptive filter. In this study we propose a new algorithm, hereinafter called Stationary Wavelet Movement Artifact Reduction (SWMAR), where the Stationary Wavelet Transform (SWT) decomposition algorithm is employed to identify and remove movement artifacts from ECG signals in horses. A comparative analysis with the Normalized Least Mean Square Adaptive Filter technique (NLMSAF) is performed as well. Results achieved on seven hours of recordings showed a reduction greater than 40% of MA percentage (between before- and after- the application of the proposed algorithm). Moreover, the comparative analysis with the NLMSAF, applied to the same ECG recordings, showed a greater reduction of MA percentage in favour of SWMAR with a statistical significant difference (p-value < 0.0.5).

  1. Dry electrode bio-potential recordings.

    Science.gov (United States)

    Gargiulo, Gaetano; Bifulco, Paolo; McEwan, Alistair; Nasehi Tehrani, Joubin; Calvo, Rafael A; Romano, Maria; Ruffo, Mariano; Shephard, Richard; Cesarelli, Mario; Jin, Craig; Mohamed, Armin; van Schaik, André

    2010-01-01

    As wireless bio-medical long term monitoring moves towards personal monitoring it demands very high input impedance systems capable to extend the reading of bio-signal during the daily activities offering a kind of "stress free", convenient connection, with no need for skin preparation. In particular we highlight the development and broad applications of our own circuits for wearable bio-potential sensor systems enabled by the use of an FET based amplifier circuit with sufficiently high impedance to allow the use of passive dry electrodes which overcome the significant barrier of gel based contacts. In this paper we present the ability of dry electrodes in long term monitoring of ECG, EEG and fetal ECG.

  2. The Effectiveness of Non-ECG-Gated Contrast-Enhanced Computed Tomography for the Diagnosis of Non-ST Segment Elevation Acute Coronary Syndrome.

    Science.gov (United States)

    Watanabe, Tomomi; Furuse, Yoshiyuki; Ohta, Yasutoshi; Kato, Masahiko; Ogawa, Toshihide; Yamamoto, Kazuhiro

    2016-09-28

    Non-ST segment elevation acute coronary syndrome (NSTE-ACS) can be difficult to diagnose accurately, especially in the hyper-acute phase. Non-ECG-gated contrast-enhanced computed tomography (non-ECG-gated CE-CT) has been used in many institutions for screening acute chest pain. Although early defects (EDs) observed in non-ECG-gated CE-CT have been reported as a sign of acute myocardial ischemia, the precise diagnostic value of this sign for acute coronary syndrome has not been fully elucidated. We investigated the usefulness of non-ECG-gated CE-CT for the diagnosis of NSTE-ACS. We retrospectively reviewed 556 patients who were hospitalized for acute-onset chest pain and who underwent emergent coronary angiography. Non-ECG-gated CE-CT was performed in 23 of these patients. Two readers independently analyzed CT images using a 5-point scale. Of the 23 patients, 13 were diagnosed with NSTE-ACS. The remaining 10 patients were diagnosed with other conditions. The sensitivity, specificity, positive predictive value, and negative predictive value, respectively, of EDs on non-ECG-gated CE-CT to detect NSTE-ACS were 84.6%, 90%, 91.7%, and 81.8%. The identification of EDs was consistent between the two readers. Non-ECG-gated CE-CT may be useful not only to triage patients with chest pain by ruling out other conditions, but also to accurately diagnose NSTE-ACS.

  3. Sparse Matrix for ECG Identification with Two-Lead Features

    Directory of Open Access Journals (Sweden)

    Kuo-Kun Tseng

    2015-01-01

    Full Text Available Electrocardiograph (ECG human identification has the potential to improve biometric security. However, improvements in ECG identification and feature extraction are required. Previous work has focused on single lead ECG signals. Our work proposes a new algorithm for human identification by mapping two-lead ECG signals onto a two-dimensional matrix then employing a sparse matrix method to process the matrix. And that is the first application of sparse matrix techniques for ECG identification. Moreover, the results of our experiments demonstrate the benefits of our approach over existing methods.

  4. The Development of a Portable ECG Monitor Based on DSP

    Science.gov (United States)

    Nan, CHI Jian; Tao, YAN Yan; Meng Chen, LIU; Li, YANG

    With the advent of global information, researches of Smart Home system are in the ascendant, the ECG real-time detection, and wireless transmission of ECG become more useful. In order to achieve the purpose we developed a portable ECG monitor which achieves the purpose of cardiac disease remote monitoring, and will be used in the physical and psychological disease surveillance in smart home system, we developed this portable ECG Monitor, based on the analysis of existing ECG Monitor, using TMS320F2812 as the core controller, which complete the signal collection, storage, processing, waveform display and transmission.

  5. Hyperkalemia Induced Brugada Phenocopy: A Rare ECG Manifestation

    Directory of Open Access Journals (Sweden)

    Muhammad Ameen

    2017-01-01

    Full Text Available Brugada syndrome (BrS is an inherited disorder of cardiac ion channels characterized by peculiar ECG findings predisposing individuals to ventricular arrhythmias, syncope, and sudden cardiac death (SCD. Various electrolyte disturbances and ion channels blocking drugs could also provoke BrS ECG findings without genetic BrS. Clinical differentiation and recognition are essential for guiding the legitimate action. Hyperkalemia is well known to cause a wide variety of ECG manifestations. Severe hyperkalemia can even cause life threatening ventricular arrhythmias and cardiac conduction abnormalities. Most common ECG findings include peaked tall T waves with short PR interval and wide QRS complex. Since it is very commonly encountered disorder, physicians need to be aware of even its rare ECG manifestations, which include ST segment elevation and Brugada pattern ECG (BrP. We are adding a case to the limited literature about hyperkalemia induced reversible Brugada pattern ECG changes.

  6. Evaluation of a novel portable capacitive ECG system in the clinical practice for a fast and simple ECG assessment in patients presenting with chest pain: FIDET (Fast Infarction Diagnosis ECG Trial)

    OpenAIRE

    Rasenack, Eva; Oehler, Martin; Elsässer, Albrecht; Schilling, Meinhard; Maier, Lars

    2012-01-01

    Background Electrocardiogram (ECG) assessment plays a crucial role in patients presenting with chest pain and suspected acute coronary syndrome (ACS). In a pilot study, we previously evaluated a capacitive ECG system (cECG) as a novel ECG technique for a fast and simple ECG assessment in patients with ST-elevation myocardial infarction (STEMI). In a next step, the sensitivity and specificity of this novel ECG technique have to be assessed in patients with ACS. Hypothesis The Fast Infarction D...

  7. A Simplified 3D Model of Whole Heart Electrical Activity and 12-Lead ECG Generation

    Directory of Open Access Journals (Sweden)

    Siniša Sovilj

    2013-01-01

    Full Text Available We present a computationally efficient three-dimensional bidomain model of torso-embedded whole heart electrical activity, with spontaneous initiation of activation in the sinoatrial node, incorporating a specialized conduction system with heterogeneous action potential morphologies throughout the heart. The simplified geometry incorporates the whole heart as a volume source, with heart cavities, lungs, and torso as passive volume conductors. We placed four surface electrodes at the limbs of the torso: , , and and six electrodes on the chest to simulate the Einthoven, Goldberger-augmented and precordial leads of a standard 12-lead system. By placing additional seven electrodes at the appropriate torso positions, we were also able to calculate the vectorcardiogram of the Frank lead system. Themodel was able to simulate realistic electrocardiogram (ECG morphologies for the 12 standard leads, orthogonal , , and leads, as well as the vectorcardiogram under normal and pathological heart states. Thus, simplified and easy replicable 3D cardiac bidomain model offers a compromise between computational load and model complexity and can be used as an investigative tool to adjust cell, tissue, and whole heart properties, such as setting ischemic lesions or regions of myocardial infarction, to readily investigate their effects on whole ECG morphology.

  8. A new algorithm to diagnose atrial ectopic origin from multi lead ECG systems--insights from 3D virtual human atria and torso.

    Science.gov (United States)

    Alday, Erick A Perez; Colman, Michael A; Langley, Philip; Butters, Timothy D; Higham, Jonathan; Workman, Antony J; Hancox, Jules C; Zhang, Henggui

    2015-01-01

    Rapid atrial arrhythmias such as atrial fibrillation (AF) predispose to ventricular arrhythmias, sudden cardiac death and stroke. Identifying the origin of atrial ectopic activity from the electrocardiogram (ECG) can help to diagnose the early onset of AF in a cost-effective manner. The complex and rapid atrial electrical activity during AF makes it difficult to obtain detailed information on atrial activation using the standard 12-lead ECG alone. Compared to conventional 12-lead ECG, more detailed ECG lead configurations may provide further information about spatio-temporal dynamics of the body surface potential (BSP) during atrial excitation. We apply a recently developed 3D human atrial model to simulate electrical activity during normal sinus rhythm and ectopic pacing. The atrial model is placed into a newly developed torso model which considers the presence of the lungs, liver and spinal cord. A boundary element method is used to compute the BSP resulting from atrial excitation. Elements of the torso mesh corresponding to the locations of the placement of the electrodes in the standard 12-lead and a more detailed 64-lead ECG configuration were selected. The ectopic focal activity was simulated at various origins across all the different regions of the atria. Simulated BSP maps during normal atrial excitation (i.e. sinoatrial node excitation) were compared to those observed experimentally (obtained from the 64-lead ECG system), showing a strong agreement between the evolution in time of the simulated and experimental data in the P-wave morphology of the ECG and dipole evolution. An algorithm to obtain the location of the stimulus from a 64-lead ECG system was developed. The algorithm presented had a success rate of 93%, meaning that it correctly identified the origin of atrial focus in 75/80 simulations, and involved a general approach relevant to any multi-lead ECG system. This represents a significant improvement over previously developed algorithms.

  9. Comparing wearable devices with wet and textile electrodes for activity recognition.

    Science.gov (United States)

    Lokare, Namita; Gonzalez, Laura; Lobaton, Edgar

    2016-08-01

    This paper explores the idea of identifying activities from muscle activation which is captured by wearable ECG recording devices that use wet and textile electrodes. Most of the devices available today filter out the high frequency components to retain only the signal related to an ECG. We explain how the high frequency components that correspond to muscle activation can be extracted from the recorded signal and can be used to identify activities. We notice that is possible to obtain good performance for both the wet and dry electrodes. However, we observed that signals from the dry textile electrodes introduce less artifacts associated with muscle activation.

  10. The problem of skin-electrode processes during medical electrography.

    Science.gov (United States)

    Tatarenko, L

    1975-01-01

    The processes were studied which take place at the skin-electrode zone when surface electrodes are applied to the human body for the medical electrography (ECG, EEG, EMG, etc.). These processes were investigated from the point of view of their influence on the distortion-resistence and the precision of the biopotential registration; they were studied also as a possible source of bioinformation. The results of the experimental research are discussed.

  11. An intelligent telecardiology system using a wearable and wireless ECG to detect atrial fibrillation.

    Science.gov (United States)

    Lin, Chin-Teng; Chang, Kuan-Cheng; Lin, Chun-Ling; Chiang, Chia-Cheng; Lu, Shao-Wei; Chang, Shih-Sheng; Lin, Bor-Shyh; Liang, Hsin-Yueh; Chen, Ray-Jade; Lee, Yuan-Teh; Ko, Li-Wei

    2010-05-01

    This study presents a novel wireless, ambulatory, real-time, and autoalarm intelligent telecardiology system to improve healthcare for cardiovascular disease, which is one of the most prevalent and costly health problems in the world. This system consists of a lightweight and power-saving wireless ECG device equipped with a built-in automatic warning expert system. This device is connected to a mobile and ubiquitous real-time display platform. The acquired ECG signals are instantaneously transmitted to mobile devices, such as netbooks or mobile phones through Bluetooth, and then, processed by the expert system. An alert signal is sent to the remote database server, which can be accessed by an Internet browser, once an abnormal ECG is detected. The current version of the expert system can identify five types of abnormal cardiac rhythms in real-time, including sinus tachycardia, sinus bradycardia, wide QRS complex, atrial fibrillation (AF), and cardiac asystole, which is very important for both the subjects who are being monitored and the healthcare personnel tracking cardiac-rhythm disorders. The proposed system also activates an emergency medical alarm system when problems occur. Clinical testing reveals that the proposed system is approximately 94% accurate, with high sensitivity, specificity, and positive prediction rates for ten normal subjects and 20 AF patients. We believe that in the future a business-card-like ECG device, accompanied with a mobile phone, can make universal cardiac protection service possible.

  12. A novel feature extracting method of QRS complex classification for mobile ECG signals

    Science.gov (United States)

    Zhu, Lingyun; Wang, Dong; Huang, Xianying; Wang, Yue

    2007-12-01

    The conventional classification parameters of QRS complex suffer from larger activity rang of patients and lower signal to noise ratio in mobile cardiac telemonitoring system and can not meet the identification needs of ECG signal. Based on individual sinus heart rhythm template built with mobile ECG signals in time window, we present semblance index to extract the classification features of QRS complex precisely and expeditiously. Relative approximation r2 and absolute error r3 are used as estimating parameters of semblance between testing QRS complex and template. The evaluate parameters corresponding to QRS width and types are demonstrated to choose the proper index. The results show that 99.99 percent of the QRS complex for sinus and superventricular ECG signals can be distinguished through r2 but its average accurate ratio is only 46.16%. More than 97.84 percent of QRS complexes are identified using r3 but its accurate ratio to the sinus and superventricular is not better than r2. By the feature parameter of width, only 42.65 percent of QRS complexes are classified correctly, but its accurate ratio to the ventricular is superior to r2. To combine the respective superiority of three parameters, a nonlinear weighing computation of QRS width, r2 and r3 is introduced and the total classification accuracy up to 99.48% by combing indexes.

  13. Magnetohydrodynamic electrode

    Science.gov (United States)

    Boquist, Carl W.; Marchant, David D.

    1978-01-01

    A ceramic-metal composite suitable for use in a high-temperature environment consists of a refractory ceramic matrix containing 10 to 50 volume percent of a continuous high-temperature metal reinforcement. In a specific application of the composite, as an electrode in a magnetohydrodynamic generator, the one surface of the electrode which contacts the MHD fluid may have a layer of varying thickness of nonreinforced refractory ceramic for electrode temperature control. The side walls of the electrode may be coated with a refractory ceramic insulator. Also described is an electrode-insulator system for a MHD channel.

  14. STUDY OF ECG CHANGES IN SMOKERS

    Directory of Open Access Journals (Sweden)

    Syamala Devi

    2014-10-01

    Full Text Available This study is intended to evaluate the changes in Electrocardiogram (ECG in apparently healthy adult male smokers. This cross-sectional study covers 40 smokers, who smoked on an average 10 cigarettes per day for at least 5 years, and 40 non-smokers to find out the possible risk factors for cardiovascular disorders. This study was conducted during April 2011 to April 2012 in the Department of Physiology of Andhra Medical College, on subjects whose age ranged from 20 to 60 years. The ECG results were evaluated for different parameters like heart rate, P-wave, P-R interval, QRS complex, QT interval, and T-wave. The results were analyzed using student’s t-test. The probability (p value was calculated. The analysis showed that QRS and QT interval were shortened and that the QTc interval was widened in the smokers, although the values did not show any statistical significance. From the statistical analysis of the results obtained in the present study and their comparison with those of published reports, it appears that smoking 10 cigarettes per day for 5 Years does not cause major change in ECG wave forms.

  15. Omnipresent ECG-Oversee Android Watch

    Directory of Open Access Journals (Sweden)

    K Navaneetha Krishnan

    2015-12-01

    Full Text Available “ Omnipresent ECG -oversee android watch” is designed to implement the increasing awareness of alteration in the rhythm of heart beat and coronary heart diseases due to stress and other risk factors. Death caused by heart diseases are high it can be reduced when a person’s heart beat rate is monitored continuously for this purpose “Omnipresent ECG -oversee android watch” is used. It can be used by higher officials/patients to keep track of their heart beat rate by self-opinion or for remote diagnosis of chronic heart disease patients before sudden flicker. This watch works by ceaseless monitoring over a person’s heart beat rate if any deflection is found it generates an alert. It is mainly used by people who are living alone or by those who suffer from any heart disease. It scales the ECG using three lead electrocardiography and impart three signals to smart watch for processing and for generating alert.

  16. ECG Sensor Card with Evolving RBP Algorithms for Human Verification

    Science.gov (United States)

    Tseng, Kuo-Kun; Huang, Huang-Nan; Zeng, Fufu; Tu, Shu-Yi

    2015-01-01

    It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs) are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP), with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack—the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH) from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals. PMID:26307995

  17. ECG Sensor Card with Evolving RBP Algorithms for Human Verification

    Directory of Open Access Journals (Sweden)

    Kuo-Kun Tseng

    2015-08-01

    Full Text Available It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP, with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack—the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals.

  18. ECG Sensor Card with Evolving RBP Algorithms for Human Verification.

    Science.gov (United States)

    Tseng, Kuo-Kun; Huang, Huang-Nan; Zeng, Fufu; Tu, Shu-Yi

    2015-08-21

    It is known that cardiac and respiratory rhythms in electrocardiograms (ECGs) are highly nonlinear and non-stationary. As a result, most traditional time-domain algorithms are inadequate for characterizing the complex dynamics of the ECG. This paper proposes a new ECG sensor card and a statistical-based ECG algorithm, with the aid of a reduced binary pattern (RBP), with the aim of achieving faster ECG human identity recognition with high accuracy. The proposed algorithm has one advantage that previous ECG algorithms lack-the waveform complex information and de-noising preprocessing can be bypassed; therefore, it is more suitable for non-stationary ECG signals. Experimental results tested on two public ECG databases (MIT-BIH) from MIT University confirm that the proposed scheme is feasible with excellent accuracy, low complexity, and speedy processing. To be more specific, the advanced RBP algorithm achieves high accuracy in human identity recognition and is executed at least nine times faster than previous algorithms. Moreover, based on the test results from a long-term ECG database, the evolving RBP algorithm also demonstrates superior capability in handling long-term and non-stationary ECG signals.

  19. A wavelet-based ECG delineation algorithm for 32-bit integer online processing

    Directory of Open Access Journals (Sweden)

    Chiari Lorenzo

    2011-04-01

    Full Text Available Abstract Background Since the first well-known electrocardiogram (ECG delineator based on Wavelet Transform (WT presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave, QRS, and mono- or bi-phasic T wave would make it a suitable candidate for efficient online processing of ambulatory ECG signals. Unfortunately, previous implementations of this method adopt non-linear operators such as root mean square (RMS or floating point algebra, which are computationally demanding. Methods This paper presents a 32-bit integer, linear algebra advanced approach to online QRS detection and P-QRS-T waves delineation of a single lead ECG signal, based on WT. Results The QRS detector performance was validated on the MIT-BIH Arrhythmia Database (sensitivity Se = 99.77%, positive predictive value P+ = 99.86%, on 109010 annotated beats and on the European ST-T Database (Se = 99.81%, P+ = 99.56%, on 788050 annotated beats. The ECG delineator was validated on the QT Database, showing a mean error between manual and automatic annotation below 1.5 samples for all fiducial points: P-onset, P-peak, P-offset, QRS-onset, QRS-offset, T-peak, T-offset, and a mean standard deviation comparable to other established methods. Conclusions The proposed algorithm exhibits reliable QRS detection as well as accurate ECG delineation, in spite of a simple structure built on integer linear algebra.

  20. Automated diagnosis of congestive heart failure using dual tree complex wavelet transform and statistical features extracted from 2s of ECG signals.

    Science.gov (United States)

    Sudarshan, Vidya K; Acharya, U Rajendra; Oh, Shu Lih; Adam, Muhammad; Tan, Jen Hong; Chua, Chua Kuang; Chua, Kok Poo; Tan, Ru San

    2017-02-07

    Identification of alarming features in the electrocardiogram (ECG) signal is extremely significant for the prediction of congestive heart failure (CHF). ECG signal analysis carried out using computer-aided techniques can speed up the diagnosis process and aid in the proper management of CHF patients. Therefore, in this work, dual tree complex wavelets transform (DTCWT)-based methodology is proposed for an automated identification of ECG signals exhibiting CHF from normal. In the experiment, we have performed a DTCWT on ECG segments of 2s duration up to six levels to obtain the coefficients. From these DTCWT coefficients, statistical features are extracted and ranked using Bhattacharyya, entropy, minimum redundancy maximum relevance (mRMR), receiver-operating characteristics (ROC), Wilcoxon, t-test and reliefF methods. Ranked features are subjected to k-nearest neighbor (KNN) and decision tree (DT) classifiers for automated differentiation of CHF and normal ECG signals. We have achieved 99.86% accuracy, 99.78% sensitivity and 99.94% specificity in the identification of CHF affected ECG signals using 45 features. The proposed method is able to detect CHF patients accurately using only 2s of ECG signal length and hence providing sufficient time for the clinicians to further investigate on the severity of CHF and treatments.

  1. A model-based approach to human identification using ECG

    Science.gov (United States)

    Homer, Mark; Irvine, John M.; Wendelken, Suzanne

    2009-05-01

    Biometrics, such as fingerprint, iris scan, and face recognition, offer methods for identifying individuals based on a unique physiological measurement. Recent studies indicate that a person's electrocardiogram (ECG) may also provide a unique biometric signature. Current techniques for identification using ECG rely on empirical methods for extracting features from the ECG signal. This paper presents an alternative approach based on a time-domain model of the ECG trace. Because Auto-Regressive Integrated Moving Average (ARIMA) models form a rich class of descriptors for representing the structure of periodic time series data, they are well-suited to characterizing the ECG signal. We present a method for modeling the ECG, extracting features from the model representation, and identifying individuals using these features.

  2. Compressed domain ECG biometric with two-lead features

    Science.gov (United States)

    Lee, Wan-Jou; Chang, Wen-Whei

    2016-07-01

    This study presents a new method to combine ECG biometrics with data compression within a common JPEG2000 framework. We target the two-lead ECG configuration that is routinely used in long-term heart monitoring. Incorporation of compressed-domain biometric techniques enables faster person identification as it by-passes the full decompression. Experiments on public ECG databases demonstrate the validity of the proposed method for biometric identification with high accuracies on both healthy and diseased subjects.

  3. [Practical experience about the compatibility of PDF converter in ECG information system].

    Science.gov (United States)

    Yang, Gang; Lu, Weishi; Zhou, Jiacheng

    2009-11-01

    To find a way to view ECG from different manufacturers in electrocardiogram information system. Different format ECG data were transmitted to ECG center by different ways. Corresponding analysis software was used to make the diagnosis reports in the center. Then we use PDF convert to change all ECG reports into PDF format. The electrocardiogram information system manage these PDF format ECG data for clinic user. The ECG reports form several major ECG manufacturers were transformed to PDF format successfully. In the electrocardiogram information system it is freely to view the ECG figure. PDF format ECG report is a practicable way to solve the compatibility problem in electrocardiogram information system.

  4. QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases.

    Science.gov (United States)

    Saini, Indu; Singh, Dilbag; Khosla, Arun

    2013-07-01

    The performance of computer aided ECG analysis depends on the precise and accurate delineation of QRS-complexes. This paper presents an application of K-Nearest Neighbor (KNN) algorithm as a classifier for detection of QRS-complex in ECG. The proposed algorithm is evaluated on two manually annotated standard databases such as CSE and MIT-BIH Arrhythmia database. In this work, a digital band-pass filter is used to reduce false detection caused by interference present in ECG signal and further gradient of the signal is used as a feature for QRS-detection. In addition the accuracy of KNN based classifier is largely dependent on the value of K and type of distance metric. The value of K = 3 and Euclidean distance metric has been proposed for the KNN classifier, using fivefold cross-validation. The detection rates of 99.89% and 99.81% are achieved for CSE and MIT-BIH databases respectively. The QRS detector obtained a sensitivity Se = 99.86% and specificity Sp = 99.86% for CSE database, and Se = 99.81% and Sp = 99.86% for MIT-BIH Arrhythmia database. A comparison is also made between proposed algorithm and other published work using CSE and MIT-BIH Arrhythmia databases. These results clearly establishes KNN algorithm for reliable and accurate QRS-detection.

  5. Arrhythmia ECG Noise Reduction by Ensemble Empirical Mode Decomposition

    Directory of Open Access Journals (Sweden)

    Kang-Ming Chang

    2010-06-01

    Full Text Available A novel noise filtering algorithm based on ensemble empirical mode decomposition (EEMD is proposed to remove artifacts in electrocardiogram (ECG traces. Three noise patterns with different power—50 Hz, EMG, and base line wander – were embedded into simulated and real ECG signals. Traditional IIR filter, Wiener filter, empirical mode decomposition (EMD and EEMD were used to compare filtering performance. Mean square error between clean and filtered ECGs was used as filtering performance indexes. Results showed that high noise reduction is the major advantage of the EEMD based filter, especially on arrhythmia ECGs.

  6. Denoising of ECG signal during spaceflight using singular value decomposition

    Science.gov (United States)

    Li, Zhuo; Wang, Li

    2009-12-01

    The Singular Value Decomposition (SVD) method is introduced to denoise the ECG signal during spaceflight. The theory base of SVD method is given briefly. The denoising process of the strategy is presented combining a segment of real ECG signal. We improve the algorithm of calculating Singular Value Ratio (SVR) spectrum, and propose a constructive approach of analysis characteristic patterns. We reproduce the ECG signal very well and compress the noise effectively. The SVD method is proved to be suitable for denoising the ECG signal.

  7. 3-lead acquisition using single channel ECG device developed on AD8232 analog front end for wireless ECG application

    Science.gov (United States)

    Agung, Mochammad Anugrah; Basari

    2017-02-01

    Electrocardiogram (ECG) devices measure electrical activity of the heart muscle to determine heart conditions. ECG signal quality is the key factor in determining the diseases of the heart. This paper presents the design of 3-lead acquistion on single channel wireless ECG device developed on AD8232 chip platform using microcontroller. To make the system different from others, monopole antenna 2.4 GHz is used in order to send and receive ECG signal. The results show that the system still can receive ECG signal up to 15 meters by line of sight (LOS) condition. The shape of ECG signals is precisely similar with the expected signal, although some delays occur between two consecutive pulses. For further step, the system will be applied with on-body antenna in order to investigate body to body communication that will give variation in connectivity from the others.

  8. The acquisition and retention of ECG interpretation skills after a standardized web-based ECG tutorial-a randomised study

    DEFF Research Database (Denmark)

    Rolskov Bojsen, Signe; Räder, Sune Bernd Emil Werner; Holst, Anders Gaardsdal

    2015-01-01

    BACKGROUND: Electrocardiogram (ECG) interpretation is of great importance for patient management. However, medical students frequently lack proficiency in ECG interpretation and rate their ECG training as inadequate. Our aim was to examine the effect of a standalone web-based ECG tutorial...... and to assess the retention of skills using multiple follow-up intervals. METHODS: 203 medical students were included in the study. All participants completed a pre-test, an ECG tutorial, and a post-test. The participants were also randomised to complete a retention-test after short (2-4 weeks), medium (10.......6), respectively). When comparing the pre-test to retention-test delta scores, junior students had learned significantly more than senior students (junior students improved 10.7 points and senior students improved 4.7 points, p = 0.003). CONCLUSION: A standalone web-based ECG tutorial can be an effective means...

  9. High-resolution detection of sustained ventricular and supraventricular tachycardia through FPGA-based fuzzy processing of ECG signal.

    Science.gov (United States)

    Roy Chowdhury, Shubhajit

    2015-10-01

    The paper presents a field-programmable gate array (FPGA)-based fast processing system with 12-channel high-resolution (24 bits) front-end for ECG signal processing. The implemented high-resolution data conversion makes the system suitable for recording of late potentials of the QRS complex in patients prone to sustained ventricular tachycardia. The system accepts ECG signals through 12 channels and then filtered to minimize baseline wander and power-line interference. The filter outputs are connected to 12 delta-sigma ADCs. The whole ADCs work synchronously at 8 kHz sampling frequency, and their output data are transferred to an FPGA that computes online on the digitized sample values in real time and ascertains whether the patient under study suffers from ventricular tachycardia or not. In order to ascertain the QRS complex accurately in the noisy ECG signal, fuzzy entropy of the sample values has been computed and provided as an input to inverse multiquadratic radial basis function neural network. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity of 99.83 % and accuracy of 99.7 % is achieved when tested using single-channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in the literature. Using the system, 200 patients have been diagnosed with an accuracy of 99 %.

  10. Spectral Statistics of RR Intervals in ECG

    CERN Document Server

    Martinis, M; Knezevic, A; Crnugelj, J

    2003-01-01

    The statistical properties (fluctuations) of heartbeat intervals (RR intervals) in ECG are studied and compared with the predictions of Random Matrix Theory (RMT). It is found that heartbeat intervals only locally exhibit the fluctuation patterns (universality) predicted by the RMT. This finding shows that heartbeat dynamics is of the mixed type where regular and irregular (chaotic) regimes coexist and the Berry-Robnik theory can be applied. It is also observed that the distribution of heartbeat intervals is well described by the one-parameter Brody distribution. The parameter $\\beta $ of the Brody distribution is seen to be connected with the dynamical state of the heart.

  11. Manifold learning based ECG-free free-breathing cardiac CINE MRI.

    Science.gov (United States)

    Usman, Muhammad; Atkinson, David; Kolbitsch, Christoph; Schaeffter, Tobias; Prieto, Claudia

    2015-06-01

    To present and validate a manifold learning (ML)-based method that can estimate both cardiac and respiratory navigator signals from electrocardiogram (ECG)-free free-breathing cardiac magnetic resonance imaging (MRI) data to achieve self-gated retrospective CINE reconstruction. In this work the use of the ML method is demonstrated for 2D cardiac CINE to achieve both cardiac and respiratory self-gating without the need of an external navigator or ECG signal. This is achieved by sequentially applying ML to two sets of retrospectively reconstructed real-time images with differing temporal resolutions. A 1D cardiac signal is estimated by applying ML to high temporal resolution real-time images reconstructed from the acquired data. Using the estimated cardiac signal, a 1D respiratory signal was obtained by applying the ML method to low temporal resolution images reconstructed from the same acquired data for each cardiac cycle. Data were acquired in five volunteers with a 2D golden angle radial trajectory in a balanced steady-state free precession (b-SSFP) acquisition. The accuracy of the estimated cardiac signal was calculated as the standard deviation of the temporal difference between the estimated signal and the recorded ECG. The correlation between the estimated respiratory signal and standard pencil beam navigator signal was evaluated. Gated CINE reconstructions (20 cardiac phases per cycle, temporal resolution ∼30 msec) using the estimated cardiac and respiratory signals were qualitatively compared against conventional ECG-gated breath-hold CINE acquisitions. Accurate cardiac signals were estimated with the proposed method, with an error standard deviation in comparison to ECG lower than 20 msec. Respiratory signals estimated with the proposed method achieved a mean cross-correlation of 94% with respect to standard pencil beam navigator signals. Good quality visual scores of 2.80 ± 0.45 (scores from 0, bad, to 4, excellent quality) were observed for the

  12. Correlation technique and least square support vector machine combine for frequency domain based ECG beat classification.

    Science.gov (United States)

    Dutta, Saibal; Chatterjee, Amitava; Munshi, Sugata

    2010-12-01

    The present work proposes the development of an automated medical diagnostic tool that can classify ECG beats. This is considered an important problem as accurate, timely detection of cardiac arrhythmia can help to provide proper medical attention to cure/reduce the ailment. The proposed scheme utilizes a cross-correlation based approach where the cross-spectral density information in frequency domain is used to extract suitable features. A least square support vector machine (LS-SVM) classifier is developed utilizing the features so that the ECG beats are classified into three categories: normal beats, PVC beats and other beats. This three-class classification scheme is developed utilizing a small training dataset and tested with an enormous testing dataset to show the generalization capability of the scheme. The scheme, when employed for 40 files in the MIT/BIH arrhythmia database, could produce high classification accuracy in the range 95.51-96.12% and could outperform several competing algorithms.

  13. An integrated bioimpedance—ECG gating technique for respiratory and cardiac motion compensation in cardiac PET

    Science.gov (United States)

    Koivumäki, Tuomas; Nekolla, Stephan G.; Fürst, Sebastian; Loher, Simone; Vauhkonen, Marko; Schwaiger, Markus; Hakulinen, Mikko A.

    2014-10-01

    Respiratory motion may degrade image quality in cardiac PET imaging. Since cardiac PET studies often involve cardiac gating by ECG, a separate respiratory monitoring system is required increasing the logistic complexity of the examination, in case respiratory gating is also needed. Thus, we investigated the simultaneous acquisition of both respiratory and cardiac gating signals using II limb lead mimicking electrode configuration during cardiac PET scans of 11 patients. In addition to conventional static and ECG-gated images, bioimpedance technique was utilized to generate respiratory- and dual-gated images. The ability of the bioimpedance technique to monitor intrathoracic respiratory motion was assessed estimating cardiac displacement between end-inspiration and -expiration. The relevance of dual gating was evaluated in left ventricular volume and myocardial wall thickness measurements. An average 7.6  ±  3.3 mm respiratory motion was observed in the study population. Dual gating showed a small but significant increase (4 ml, p = 0.042) in left ventricular myocardial volume compared to plain cardiac gating. In addition, a thinner myocardial wall was observed in dual-gated images (9.3  ±  1.3 mm) compared to cardiac-gated images (11.3  ±  1.3 mm, p = 0.003). This study shows the feasibility of bioimpedance measurements for dual gating in a clinical setting. The method enables simultaneous acquisition of respiratory and cardiac gating signals using a single device with standard ECG electrodes.

  14. Optimisation of embryonic and larval ECG measurement in zebrafish for quantifying the effect of QT prolonging drugs.

    Directory of Open Access Journals (Sweden)

    Sundeep Singh Dhillon

    Full Text Available Effective chemical compound toxicity screening is of paramount importance for safe cardiac drug development. Using mammals in preliminary screening for detection of cardiac dysfunction by electrocardiography (ECG is costly and requires a large number of animals. Alternatively, zebrafish embryos can be used as the ECG waveform is similar to mammals, a minimal amount of chemical is necessary for drug testing, while embryos are abundant, inexpensive and represent replacement in animal research with reduced bioethical concerns. We demonstrate here the utility of pre-feeding stage zebrafish larvae in detection of cardiac dysfunction by electrocardiography. We have optimised an ECG recording system by addressing key parameters such as the form of immobilization, recording temperature, electrode positioning and developmental age. Furthermore, analysis of 3 days post fertilization (dpf zebrafish embryos treated with known QT prolonging drugs such as terfenadine, verapamil and haloperidol led to reproducible detection of QT prolongation as previously shown for adult zebrafish. In addition, calculation of Z-factor scores revealed that the assay was sensitive and specific enough to detect large drug-induced changes in QTc intervals. Thus, the ECG recording system is a useful drug-screening tool to detect alteration to cardiac cycle components and secondary effects such as heart block and arrhythmias in zebrafish larvae before free feeding stage, and thus provides a suitable replacement for mammalian experimentation.

  15. The evolution of ambulatory ECG monitoring.

    Science.gov (United States)

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health.

  16. Design and Realization of A Mobile ECG Monitoring System Based on Bluetooth Technology%基于蓝牙传输的手机心电监护系统设计与实现

    Institute of Scientific and Technical Information of China (English)

    田福英; 沈铁明; 刘博宇

    2013-01-01

    Objective:We developed a portable ECG monitoring system with wireless transmission technology.Methods:The ECG acquisition module,which uses the MSP430 chip as the core,gathers and amplifies the ECG signals,eliminates noises,converts to digital signals and then sends by bluetooth.The ECG monitoring program running on the smartphone receives the ECG signals and displays them on the phone surface in real time.It also calculates heart rates,stores in files and alarms with abnormal ECG.In data processing,we used median filtering to eliminate signal drift and applied a notch filter to remove noise of power-line interference at 50Hz.Then we applied a length transform method on ECG sections to quickly locate R waves and calculate heart rate in time.Results:We designed and completed the hardware circuit board and software programs of ECG acquisition module.We also programmed ECG monitoring applications which can run on a android mobile phone.The ECG signals are transmitted from ECG acquisition module to the mobile phone by bluetooth.The system picks up human ECG signals through electrodes and then displays them on the phone surface finally.The monitoring program can eliminate noises clearly and calculate the heart rate accurately in real time,and drive the bell alarm and saving the abnormal data segment when the heart rate exceeds the scope.The whole system runs smoothly with good real-time performance and stability.Conclusions:The system has features of small volume,low power consumption and simple operation.The implementation of this system will lighten the productization of the mobile human physiological information monitoring system which may be based on a smartphone or other mobile devices.It will promote mobile computing in health care area.%目的:本文利用智能手机平台设计并实现了一个基于蓝牙传输功能的便携式心电监护系统.方法:整个系统分为心电采集模块和用于心电显示与处理的手机

  17. Enhancement of Twins Fetal ECG Signal Extraction Based on Hybrid Blind Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Ahmed Kareem Abdullah

    2017-07-01

    Full Text Available ECG machines are noninvasive system used to measure the heartbeat signal. It’s very important to monitor the fetus ECG signals during pregnancy to check the heat activity and to detect any problem early before born, therefore the monitoring of ECG signals have clinical significance and importance. For multi-fetal pregnancy case the classical filtering algorithms are not sufficient to separate the ECG signals between mother and fetal. In this paper the mixture consists of mixing from three ECG signals, the first signal is the mother ECG (M-ECG signal, second signal the Fetal-1 ECG (F1-ECG, and third signal is the Fetal-2 ECG (F2-ECG, these signals are extracted based on modified blind source extraction (BSE techniques. The proposed work based on hybridization between two BSE techniques to ensure that the extracted signals separated well. The results demonstrate that the proposed work very efficiently to extract the useful ECG signals

  18. Brugada Syndrome ECG Is Highly Prevalent in Schizophrenia

    NARCIS (Netherlands)

    Blom, Marieke T.; Cohen, Dan; Seldenrijk, Adrie; Penninx, Brenda W. J. H.; Nijpels, Giel; Stehouwer, Coen D. A.; Dekker, Jacqueline M.; Tan, Hanno L.

    2014-01-01

    Background The causes of increased risk of sudden cardiac death in schizophrenia are not resolved. We aimed to establish (1) whether ECG markers of sudden cardiac death risk, in particular Brugada-ECG pattern, are more prevalent among patients with schizophrenia, and (2) whether increased prevalence

  19. Simultaneous comparison of 1 gel with 4 dry electrode types for electrocardiography.

    Science.gov (United States)

    Meziane, N; Yang, S; Shokoueinejad, M; Webster, J G; Attari, M; Eren, H

    2015-03-01

    We designed a spandex tank top with dry electrodes for continuous electrocardiogram (ECG) recording. This pilot study determined the best fabric, the best electrode types, sizes, and locations. Optimal electrodes provide high signal to artifact ratio (SAR) and reliability by meeting the following criteria: 1) low baseline shift, 2) high adhesion, 3) good physical stability, 4) large effective area, 5) thin with high flexibility (Luo et al 1992). We compared electrodes from three main groups: Ag/AgCl gel electrode, commercial conductive rubber and foam-metal based electrodes. Ag/AgCl gel electrodes are easy to apply, make good body contact and do not slip during the course of an experiment. We found that higher SARs are obtained when electrode area is increased (40 mm diameter) and the two dry measurement electrodes are located on convex areas (over chest muscle) rather than concave areas (over sternum), so the spandex will apply light pressure to the dry electrode to yield good electrode to skin contact. We experimentally validated findings with 24 subjects: 12 men and 12 women wearing the tank top with gel and dry electrodes, by monitoring movements imitating daily life while continuously recording their ECGs.

  20. A novel similarity comparison approach for dynamic ECG series.

    Science.gov (United States)

    Yin, Hong; Zhu, Xiaoqian; Ma, Shaodong; Yang, Shuqiang; Chen, Liqian

    2015-01-01

    The heart sound signal is a reflection of heart and vascular system motion. Long-term continuous electrocardiogram (ECG) contains important information which can be helpful to prevent heart failure. A single piece of a long-term ECG recording usually consists of more than one hundred thousand data points in length, making it difficult to derive hidden features that may be reflected through dynamic ECG monitoring, which is also very time-consuming to analyze. In this paper, a Dynamic Time Warping based on MapReduce (MRDTW) is proposed to make prognoses of possible lesions in patients. Through comparison of a real-time ECG of a patient with the reference sets of normal and problematic cardiac waveforms, the experimental results reveal that our approach not only retains high accuracy, but also greatly improves the efficiency of the similarity measure in dynamic ECG series.

  1. Advances in Modern Capacitive ECG Systems for Continuous Cardiovascular Monitoring

    Directory of Open Access Journals (Sweden)

    A. Schommartz

    2011-01-01

    Full Text Available The technique of capacitive electrocardiography (cECG is very promising in a flexible manner. Already integrated into several everyday objects, the single lead cECG system has shown that easy-to-use measurements of electrocardiograms are possible without difficult preparation of the patients. Multi-channel cECG systems enable the extraction of ECG signals even in the presence of coupled interferences, due to the additional redundant information. Thus, this paper presents challenges for electronic hardware design to build on developments in recent years, going from the one-lead cECG system to multi-channel systems in order to provide robust measurements - e.g. even while driving an automobile.

  2. A method of ECG template extraction for biometrics applications.

    Science.gov (United States)

    Zhou, Xiang; Lu, Yang; Chen, Meng; Bao, Shu-Di; Miao, Fen

    2014-01-01

    ECG has attracted widespread attention as one of the most important non-invasive physiological signals in healthcare-system related biometrics for its characteristics like ease-of-monitoring, individual uniqueness as well as important clinical value. This study proposes a method of dynamic threshold setting to extract the most stable ECG waveform as the template for the consequent ECG identification process. With the proposed method, the accuracy of ECG biometrics using the dynamic time wraping for difference measures has been significantly improved. Analysis results with the self-built electrocardiogram database show that the deployment of the proposed method was able to reduce the half total error rate of the ECG biometric system from 3.35% to 1.45%. Its average running time on the platform of android mobile terminal was around 0.06 seconds, and thus demonstrates acceptable real-time performance.

  3. Noncontact ECG system for unobtrusive long-term monitoring.

    Science.gov (United States)

    McDonald, Neil J; Anumula, Harini A; Duff, Eric; Soussou, Walid

    2012-01-01

    This paper describes measurements made using an ECG system with QUASAR's capacitive bioelectrodes integrated into a pad system that is placed over a chair. QUASAR's capacitive bioelectrode has the property of measuring bioelectric potentials at a small separation from the body. This enables the measurement of ECG signals through fabric, without the removal of clothing or preparation of skin. The ECG was measured through the subject's clothing while the subject sat in the chair without any supporting action from the subject. The ECG pad system is an example of a high compliance system that places minimal requirements upon the subject and, consequently, can be used to generate a long-term record from ECG segments collected on a daily basis, providing valuable information on long-term trends in cardiac health.

  4. Reduced Comparator Flash ADC for ECG Applications

    Directory of Open Access Journals (Sweden)

    Saravanan. V. A

    2013-03-01

    Full Text Available A CMOS based low power 4-bit Flash Analog to Digital Converter (ADC design with reduced number of comparators than the conventional Flash Analog to Digital Converter and multiplexer based architecture is proposed. For improving the conversion rate, both the analog and digital parts of the ADC are fully modified and the architecture uses only 4 comparators instead of 15 as used in conventional flash ADC, thus saving considerable amount of power. The proposed 4-bit ADC is designed and simulated in TANNER tools with 1.2 V supply voltage using TSpice simulation. The proposed design consumes low power of 2.15mW and operates at a faster rate hence it is suitable for ECG applications.

  5. Preprocessing and Analysis of Digitized ECGs

    Science.gov (United States)

    Villalpando, L. E. Piña; Kurmyshev, E.; Ramírez, S. Luna; Leal, L. Delgado

    2008-08-01

    In this work we propose a methodology and programs in MatlabTM that perform the preprocessing and analysis of the derivative D1 of ECGs. The program makes the correction to isoelectric line for each beat, calculates the average cardiac frequency and its standard deviation, generates a file of amplitude of P, Q and T waves, as well as the segments and intervals important of each beat. Software makes the normalization of beats to a standard rate of 80 beats per minute, the superposition of beats is done centering R waves, before and after normalizing the amplitude of each beat. The data and graphics provide relevant information to the doctor for diagnosis. In addition, some results are displayed similar to those presented by a Holter recording.

  6. The RR interval spectrum, the ECG signal and aliasing

    CERN Document Server

    Gersten, A; Ronen, A; Cassuto, Y

    1999-01-01

    A reliable spectral analysis requires sampling rate at least twice as large as the frequency bound, otherwise the analysis will be unreliable and plagued with aliasing distortions. The RR samplings do not satisfy the above requirements and therefore their spectral analysis might be unreliable. In order to demonstrate the feasibility of aliasing in RR spectral analysis, we have done an experiment which have shown clearly how the aliasing was developed. In the experiments, one of us (A.G) had kept his high breathing rate constant with the aid of metronome for more than 5 minutes. The breathing rate was larger than one-half the heart rate. Very accurate results were obtained and the resulting aliasing well understood. To our best knowledge this is the first controlled experiment of this kind coducted on humans. We compared the RR spectral analysis with the spectrum of the ECG signals from which the RR intervals were extracted. In the significant for RR analysis frequencies (below one-half Hertz) significant diff...

  7. An optimized DSP implementation of adaptive filtering and ICA for motion artifact reduction in ambulatory ECG monitoring.

    Science.gov (United States)

    Berset, Torfinn; Geng, Di; Romero, Iñaki

    2012-01-01

    Noise from motion artifacts is currently one of the main challenges in the field of ambulatory ECG recording. To address this problem, we propose the use of two different approaches. First, an adaptive filter with electrode-skin impedance as a reference signal is described. Secondly, a multi-channel ECG algorithm based on Independent Component Analysis is introduced. Both algorithms have been designed and further optimized for real-time work embedded in a dedicated Digital Signal Processor. We show that both algorithms improve the performance of a beat detection algorithm when applied in high noise conditions. In addition, an efficient way of choosing this methods is suggested with the aim of reduce the overall total system power consumption.

  8. Diagnostic Role of ECG Recording Simultaneously With EEG Testing.

    Science.gov (United States)

    Kendirli, Mustafa Tansel; Aparci, Mustafa; Kendirli, Nurten; Tekeli, Hakan; Karaoglan, Mustafa; Senol, Mehmet Guney; Togrol, Erdem

    2015-07-01

    Arrhythmia is not uncommon in the etiology of syncope which mimics epilepsy. Data about the epilepsy induced vagal tonus abnormalities have being increasingly reported. So we aimed to evaluate what a neurologist may gain by a simultaneous electrocardiogram (ECG) and electroencephalogram (EEG) recording in the patients who underwent EEG testing due to prediagnosis of epilepsy. We retrospectively evaluated and detected ECG abnormalities in 68 (18%) of 376 patients who underwent EEG testing. A minimum of 20 of minutes artifact-free recording were required for each patient. Standard 1-channel ECG was simultaneously recorded in conjunction with the EEG. In all, 28% of females and 14% of males had ECG abnormalities. Females (mean age 49 years, range 18-88 years) were older compared with the male group (mean age 28 years, range 16-83 years). Atrial fibrillation was more frequent in female group whereas bradycardia and respiratory sinus arrhythmia was higher in male group. One case had been detected a critical asystole indicating sick sinus syndrome in the female group and treated with a pacemaker implantation in the following period. Simultaneous ECG recording in conjunction with EEG testing is a clinical prerequisite to detect and to clarify the coexisting ECG and EEG abnormalities and their clinical relevance. Potentially rare lethal causes of syncope that mimic seizure or those that could cause resistance to antiepileptic therapy could effectively be distinguished by detecting ECG abnormalities coinciding with the signs and abnormalities during EEG recording.

  9. Evaluation of a Rapid Anisotropic Model for ECG Simulation

    Directory of Open Access Journals (Sweden)

    Simone Pezzuto

    2017-05-01

    Full Text Available State-of-the-art cardiac electrophysiology models that are able to deliver physiologically motivated activation maps and electrocardiograms (ECGs can only be solved on high-performance computing architectures. This makes it nearly impossible to adopt such models in clinical practice. ECG imaging tools typically rely on simplified models, but these neglect the anisotropic electric conductivity of the tissue in the forward problem. Moreover, their results are often confined to the heart-torso interface. We propose a forward model that fully accounts for the anisotropic tissue conductivity and produces the standard 12-lead ECG in a few seconds. The activation sequence is approximated with an eikonal model in the 3d myocardium, while the ECG is computed with the lead-field approach. Both solvers were implemented on graphics processing units and massively parallelized. We studied the numerical convergence and scalability of the approach. We also compared the method to the bidomain model in terms of ECGs and activation maps, using a simplified but physiologically motivated geometry and 6 patient-specific anatomies. The proposed methods provided a good approximation of activation maps and ECGs computed with a bidomain model, in only a few seconds. Both solvers scaled very well to high-end hardware. These methods are suitable for use in ECG imaging methods, and may soon become fast enough for use in interactive simulation tools.

  10. A novel approach for the diagnosis of ventricular tachycardia based on phase space reconstruction of ECG

    CERN Document Server

    Koulaouzidis, George; Cappiello, Grazia; Mazomenos, Evangelos B; Maharatna, Koushik; Morgan, John

    2014-01-01

    Ventricular arrhythmias comprise a group of disorders which manifest clinically in a variety of ways from ventricular premature beats (VPB) and no sustained ventricular tachycardia (in healthy subjects) to sudden cardiac death due to ventricular tachyarrhythmia in patients with and/or without structural heart disease. Ventricular fibrillation (VF) and ventricular tachycardia (VT) are the most common electrical mechanisms for cardiac arrest. Accurate and automatic recognition of these arrhythmias from electrocardiography (ECG) is a crucial task for medical professionals. The purpose of this research is to develop a new index for the differential diagnosis of normal sinus rhythm (SR) and ventricular arrhythmias, based on phase space reconstruction (PSR).

  11. Developing barbed microtip-based electrode arrays for biopotential measurement.

    Science.gov (United States)

    Hsu, Li-Sheng; Tung, Shu-Wei; Kuo, Che-Hsi; Yang, Yao-Joe

    2014-07-10

    This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back side, a through-silicon via was created during the wet etching process. The experimental results show that the forces required to detach the barbed microtip arrays from human skin, a polydimethylsiloxane (PDMS) polymer, and a polyvinylchloride (PVC) film were larger compared with those required to detach microtip arrays that lacked barbs. The impedances of the skin-electrode interface were measured and the performance levels of the proposed dry electrode were characterized. Electrode prototypes that employed the proposed tip arrays were implemented. Electroencephalogram (EEG) and electrocardiography (ECG) recordings using these electrode prototypes were also demonstrated.

  12. ECG signal analysis with wavelets and neural networks in FPGA

    OpenAIRE

    Klaus Raizer

    2010-01-01

    Resumo: Este trabalho apresenta a implementação de um sistema de análise de sinais de ECGs (eletrocardiogramas) embarcado em FPGA (field programmable gate array), capaz de classificar cardiopatias. A análise de ECGs é de grande importância devido a sua natureza potencialmente não-invasiva, baixo custo e alta eficiência na identificação de patologias cardíacas. Visto que um sinal de ECG pode ser composto por horas de gravação da atividade cardíaca, uma abordagem computacional para a sua anális...

  13. Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

    Science.gov (United States)

    Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Starc, V.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M.A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead

  14. Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany)], E-mail: dominik.ketelsen@med.uni-tuebingen.de; Thomas, Christoph; Werner, Matthias; Luetkhoff, Marie H. [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Buchgeister, Markus [Departments of Radiotherapy and Radiooncology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Tsiflikas, Ilias; Reimann, Anja [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Burgstahler, Christof [Department of Cardiology, University Hospital Tuebingen, Ottfried-Mueller-Strasse 10, 72076 Tuebingen (Germany); Brodoefel, Harald; Kopp, Andreas F.; Claussen, Claus D.; Heuschmid, Martin [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany)

    2010-02-15

    Purpose: The aim of the study was to estimate radiation exposure of coronary calcium scoring and angiography using ECG-gated and ECG-triggered dual-source computed tomography. Materials and methods: An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for all dose measurements. Effective dose was calculated according to ICRP 103. Radiation exposure was performed on a dual-source computed tomography (DSCT) scanner with standard protocols for calcium scoring (DSCT-Ca) and coronary angiography (DSCTA) at different heart rates (40-100 beats/min). Furthermore, a scanning protocol with ECG-triggering as well as a standard chest CT scan were evaluated. Results: Depending on gender, heart rate and ECG-pulsing, the effective dose of a complete cardiac DSCT (DSCT-Ca and DSCTA) scan varies from 10.2 to 32.6 mSv. The effective radiation dose increased significantly with lower heart rates (p < 0.035). ECG-pulsing reduced the radiation exposure significantly in DSCTA (p < 0.001). Due to breast tissue in the primary scan range, females' doses showed an increase up to 69.9% compared to males in scan protocols without ECG-pulsing. Prospective ECG-triggered DSCTA resulted in estimated effective doses from 2.8 mSv (males) to 4.1 mSv (females). Conclusion: The ECG-pulsing technique has proven its effectiveness to reduce effective dose in coronary CT angiography and is recommended for all patients with regular heart rates. The patient's heart rate influences the radiation exposure with a significant decrease at higher heart rates. Due to its lower dose, ECG-triggered DSCTA should be implemented for special indications, i.e. for diagnosis of pathologies of the aortic root and the ascending aorta.

  15. The 24-lead ECG display for enhanced recognition of STEMI-equivalent patterns in the 12-lead ECG.

    Science.gov (United States)

    Pahlm, Ulrika; Pahlm, Olle; Wagner, Galen S

    2014-01-01

    In a patient with chest pain and suspected acute coronary syndrome, the electrocardiogram (ECG) is the only readily available diagnostic tool. It is important to maximize its usefulness to detect acute myocardial ischemia that may evolve to myocardial infarction unless the patient is treated expediently with reperfusion therapy. Since diagnostic guidelines have usually included only ST-elevation myocardial infarction (STEMI) as the entity that should be diagnosed and treated urgently, a patient with coronary occlusion represented on ECG as ST depression is likely not to be considered a candidate for receiving immediate coronary angiography and coronary intervention. ECG criteria for STEMI detection require that ST elevation meet predetermined millivolt thresholds and appear in at least two spatially contiguous ECG leads. The typical ECG reader recognizes only three contiguous pairs: aVL and I; II and aVF; aVF and III. However, viewing the "orderly sequenced" 12-lead ECG display, two more contiguous pairs become obvious in the frontal plane: +I and -aVR; -aVR and +II. The 24-lead ECG is a display of the standard 12-lead ECG as both the classical positive leads and their negative (inverted) counterparts. Leads +V1, +V2, +V3, +V4, +V5, and +V6 and their inverted counterparts are used to generate a "clock-face display" for the transverse plane. Similarly, +aVL, +I, -aVR, +II, +aVF, +III in the frontal plane and their inverted counterparts are used to generate a clock-face display for the frontal plane. Optimum results, 78% sensitivity and 93% specificity, were obtained using the following 19 ECG leads: frontal plane: +aVR, -III, +aVL, +I, -aVR, +II, +aVF, +III, -aVL; transverse plane: +V1, +V2, +V3, +V4, +V5, +V6, -V1, -V2, -V3.

  16. Effect of precordial electrocardiographic electrode placement on ST-segment measurement during exercise.

    Science.gov (United States)

    Bertolet, B D; Boyette, A F; Mardis, M; Hill, J A

    1995-04-01

    Research protocols often utilize serial exercise testing to examine the efficacy of anti-ischemic therapies. These tests, however, are prone to multiple sources of bias. This investigation sought to determine the influence of varying precordial electrocardiographic (ECG) electrode placement on the detection of exercise-induced ST-segment shifts. Fifteen coronary artery disease patients with abnormal exercise tests were studied. Based on the previous exercise test, the precordial electrode position exhibiting the greatest ST-segment shift was selected as the reference electrode. Four additional electrodes were placed around this reference electrode and exercise testing was performed. ECG strips were recorded every minute. The time-to-onset and -offset of ischemic-type ST-segment depression was recorded. ST-segment depression was recorded during exercise from the reference electrode in 12 of 15 patients. Ischemic-type ST-depression was also recorded in each of these 12 patients with the surrounding electrodes; however, the time-to-onset detected by all four surrounding electrodes concurred in only 5 of 12 (42%) patients. The time-to-offset of the ST-segment depression concurred in 9 of 12 (75%) patients. Serial ECGs recorded from similar but not exactly the same precordial ECG electrode position should yield similar results for the detection of ischemia, but time-to-onset or -offset of ischemia may differ by 60 s or more. Small changes in the time-to-onset and -offset of ischemia should not be considered reliable indicators of anti-ischemia efficacy.

  17. A harmonic linear dynamical system for prominent ECG feature extraction.

    Science.gov (United States)

    Thi, Ngoc Anh Nguyen; Yang, Hyung-Jeong; Kim, SunHee; Do, Luu Ngoc

    2014-01-01

    Unsupervised mining of electrocardiography (ECG) time series is a crucial task in biomedical applications. To have efficiency of the clustering results, the prominent features extracted from preprocessing analysis on multiple ECG time series need to be investigated. In this paper, a Harmonic Linear Dynamical System is applied to discover vital prominent features via mining the evolving hidden dynamics and correlations in ECG time series. The discovery of the comprehensible and interpretable features of the proposed feature extraction methodology effectively represents the accuracy and the reliability of clustering results. Particularly, the empirical evaluation results of the proposed method demonstrate the improved performance of clustering compared to the previous main stream feature extraction approaches for ECG time series clustering tasks. Furthermore, the experimental results on real-world datasets show scalability with linear computation time to the duration of the time series.

  18. A Harmonic Linear Dynamical System for Prominent ECG Feature Extraction

    Directory of Open Access Journals (Sweden)

    Ngoc Anh Nguyen Thi

    2014-01-01

    Full Text Available Unsupervised mining of electrocardiography (ECG time series is a crucial task in biomedical applications. To have efficiency of the clustering results, the prominent features extracted from preprocessing analysis on multiple ECG time series need to be investigated. In this paper, a Harmonic Linear Dynamical System is applied to discover vital prominent features via mining the evolving hidden dynamics and correlations in ECG time series. The discovery of the comprehensible and interpretable features of the proposed feature extraction methodology effectively represents the accuracy and the reliability of clustering results. Particularly, the empirical evaluation results of the proposed method demonstrate the improved performance of clustering compared to the previous main stream feature extraction approaches for ECG time series clustering tasks. Furthermore, the experimental results on real-world datasets show scalability with linear computation time to the duration of the time series.

  19. ECG Changes In Patients On Chronic Psychotropic medication

    African Journals Online (AJOL)

    2006-08-31

    Aug 31, 2006 ... lack of exercise, obesity, substance misuse) and high autonomic ... heart; however, it might precipitate complete heart block in the presence of .... ECG changes such as rate, rhythm, T waves and QT interval changes have ...

  20. ECG Data Encryption Then Compression Using Singular Value Decomposition.

    Science.gov (United States)

    Liu, Ting Yu; Lin, Kuan Jen; Wu, Hsi-Chun

    2017-04-27

    Electrocardiogram (ECG) monitoring systems are widely used in healthcare. ECG data must be compressed for transmission and storage. Furthermore, there is a need to be able to directly process biomedical signals in encrypted domains to ensure the protection of patients' privacy. Existing encryption-then-compression (ETC) approaches for multimedia using the state-of-the-art encryption techniques inevitably sacrifice the compression efficiency or signal quality. This paper presents the first ETC approach for processing ECG data. The proposed approach not only can protect data privacy but also provide the same quality of the reconstructed signals without sacrificing the compression efficiency relative to unencrypted compressions. Specifically, the singular value decomposition (SVD) technique is used to compress the data such that the proposed system can provide quality-control compressed data, even though the data has been encrypted. Experimental results prove the proposed system to be an effective technique for assuring data security as well as compression performance for ECG data.

  1. ECG manifestations of left ventricular electrical remodeling.

    Science.gov (United States)

    Estes, E Harvey

    2012-01-01

    Research and thinking about the electrocardiographic manifestations of left ventricular hypertrophy has been constrained by a limited conceptual model of the process: heart disease produces chamber enlargement (increased mass), which in turn produces an altered electrocardiogram. The process is much more complex than can be represented in this simple model. A more robust and intricate model is proposed, in which heart (and vascular) disease causes structural changes, electrical changes, biochemical changes, and others, all of which interact to produce electrical remodeling of ventricular myocardium. This electrical remodeling results in a variety of ECG changes. All of these changes interact, leading to an altered clinical course, and to premature death. It is suggested that research, based on this model, can provide new clues to the processes involved, and improve the prediction of clinical outcomes. New directions in research, in recording equipment, and in organizational activities are suggested to test this new model, and to improve the usefulness of the electrocardiogram as a research and diagnostic tool.

  2. Near Field Communication-based telemonitoring with integrated ECG recordings.

    Science.gov (United States)

    Morak, J; Kumpusch, H; Hayn, D; Leitner, M; Scherr, D; Fruhwald, F M; Schreier, G

    2011-01-01

    Telemonitoring of vital signs is an established option in treatment of patients with chronic heart failure (CHF). In order to allow for early detection of atrial fibrillation (AF) which is highly prevalent in the CHF population telemonitoring programs should include electrocardiogram (ECG) signals. It was therefore the aim to extend our current home monitoring system based on mobile phones and Near Field Communication technology (NFC) to enable patients acquiring their ECG signals autonomously in an easy-to-use way. We prototypically developed a sensing device for the concurrent acquisition of blood pressure and ECG signals. The design of the device equipped with NFC technology and Bluetooth allowed for intuitive interaction with a mobile phone based patient terminal. This ECG monitoring system was evaluated in the course of a clinical pilot trial to assess the system's technical feasibility, usability and patient's adherence to twice daily usage. 21 patients (4f, 54 ± 14 years) suffering from CHF were included in the study and were asked to transmit two ECG recordings per day via the telemonitoring system autonomously over a monitoring period of seven days. One patient dropped out from the study. 211 data sets were transmitted over a cumulative monitoring period of 140 days (overall adherence rate 82.2%). 55% and 8% of the transmitted ECG signals were sufficient for ventricular and atrial rhythm assessment, respectively. Although ECG signal quality has to be improved for better AF detection the developed communication design of joining Bluetooth and NFC technology in our telemonitoring system allows for ambulatory ECG acquisition with high adherence rates and system usability in heart failure patients.

  3. Sampling Rate Independent Filtration Approach for Automatic ECG Delineation

    CERN Document Server

    Chereda, Hryhorii; Tymoshenko, Yury

    2016-01-01

    In this paper different types of ECG automatic delineation approaches were overviewed. A combination of these approaches was used to create sampling rate independent filtration algorithm for automatic ECG delineation that is capable of distinguishing different morphologies of T and P waves and QRS complexes. Created filtration algorithm was compared with algorithme \\`a trous. It was investigated that continuous wavelets transform with proposed automatic adaptation for different sampling rates procedure can be used for delineation problem.

  4. Human ECG signal parameters estimation during controlled physical activity

    Science.gov (United States)

    Maciejewski, Marcin; Surtel, Wojciech; Dzida, Grzegorz

    2015-09-01

    ECG signal parameters are commonly used indicators of human health condition. In most cases the patient should remain stationary during the examination to decrease the influence of muscle artifacts. During physical activity, the noise level increases significantly. The ECG signals were acquired during controlled physical activity on a stationary bicycle and during rest. Afterwards, the signals were processed using a method based on Pan-Tompkins algorithms to estimate their parameters and to test the method.

  5. Microprocessor-based simulator of surface ECG signals

    Energy Technology Data Exchange (ETDEWEB)

    MartInez, A E [Catedra de BioingenierIa II, Facultad de Ingenieria, Universidad Nacional de Entre Rios (FI-UNER), Ruta Provincial 11 Km.10 Oro Verde (Dpto. Parana) - Entre Rios (Argentina); Rossi, E [Catedra de BioingenierIa II, Facultad de Ingenieria, Universidad Nacional de Entre Rios (FI-UNER), Ruta Provincial 11 Km.10 Oro Verde (Dpto. Parana) - Entre Rios (Argentina); Siri, L Nicola [Catedra de BioingenierIa II, Facultad de Ingenieria, Universidad Nacional de Entre Rios (FI-UNER), Ruta Provincial 11 Km.10 Oro Verde (Dpto. Parana) - Entre Rios (Argentina)

    2007-11-15

    In this work, a simulator of surface electrocardiogram recorded signals (ECG) is presented. The device, based on a microcontroller and commanded by a personal computer, produces an analog signal resembling actual ECGs, not only in time course and voltage levels, but also in source impedance. The simulator is a useful tool for electrocardiograph calibration and monitoring, to incorporate as well in educational tasks and in clinical environments for early detection of faulty behaviour.

  6. Microvoltammetric Electrodes.

    Science.gov (United States)

    1985-09-25

    Microvoltammetric Electrodes, J. 0. Howell, R. M. Wightman, Anal. Chem., 56, 524-529 (1984). 2. Flow Rate Independent Amperometric Cell , W. L. Caudill...Electroanal. Chem., 182, 113-122 (1985). C. List of all publications 1. Flow Rate Independent Amperometric Cell , W. L. Caudill, J. 0. Howell, R. M

  7. Influence of Mobile Phones on the Quality of ECG Signal Acquired by Medical Devices

    Science.gov (United States)

    Buczkowski, T.; Janusek, D.; Zavala-Fernandez, H.; Skrok, M.; Kania, M.; Liebert, A.

    2013-10-01

    Health aspects of the use of radiating devices, like mobile phones, are still a public concern. Stand-alone electrocardiographic systems and those built-in, more sophisticated, medical devices have become a standard tool used in everyday medical practice. GSM mobile phones might be a potential source of electromagnetic interference (EMI) which may affect reliability of medical appliances. Risk of such event is particularly high in places remote from GSM base stations in which the signal received by GSM mobile phone is weak. In such locations an increase in power of transmitted radio signal is necessary to enhance quality of the communication. In consequence, the risk of interference of electronic devices increases because of the high level of EMI. In the present paper the spatial, temporal, and spectral characteristics of the interference have been examined. The influence of GSM mobile phone on multilead ECG recordings was studied. It was observed that the electrocardiographic system was vulnerable to the interference generated by the GSM mobile phone working with maximum transmit power and in DTX mode when the device was placed in a distance shorter than 7.5 cm from the ECG electrode located on the surface of the chest. Negligible EMI was encountered at any longer distance.

  8. Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare.

    Science.gov (United States)

    Yoon, Youngzoon; Cho, Jung H; Yoon, Gilwon

    2009-08-01

    Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure (BP) was estimated from pulse transit time (PTT) and PPG waveform. PTT is a time interval between an R-wave of electrocardiography (ECG) and a photoplethysmography (PPG) signal. This method does not require an aircuff and only a minimal inconvenience of attaching electrodes and LED/photo detector sensors on a subject. PTT computed between the ECG R-wave and the maximum first derivative PPG was strongly correlated with systolic blood pressure (SBP) (R = -0.712) compared with other PTT values, and the diastolic time proved to be appropriate for estimation diastolic blood pressure (DBP) (R = -0.764). The percent errors of SBP using the individual regression line (4-11%) were lower than those using the regression line obtained from all five subjects (9-14%). On the other hand, the DBP estimation did not show much difference between the individual regression (4-10%) and total regression line (6-10%). Our developed device had a total size of 7 x 13.5 cm and was operated by single 3-V battery. Biosignals can be measured for 72 h continuously without external interruptions. Through a serial network communication, an external personal computer can monitor measured waveforms in real time. Our proposed method can be used for non-constrained, thus continuous BP monitoring for the purpose of personal healthcare.

  9. ECG on the road: robust and unobtrusive estimation of heart rate.

    Science.gov (United States)

    Wartzek, Tobias; Eilebrecht, Benjamin; Lem, Jeroen; Lindner, Hans-Joachim; Leonhardt, Steffen; Walter, Marian

    2011-11-01

    Modern automobiles include an increasing number of assistance systems to increase the driver's safety. This feasibility study investigated unobtrusive capacitive ECG measurements in an automotive environment. Electrodes integrated into the driving seat allowed to measure a reliable ECG in 86% of the drivers; when only (light) cotton clothing was worn by the drivers, this value increased to 95%. Results show that an array of sensors is needed that can adapt to the different drivers and sitting positions. Measurements while driving show that traveling on the highway does not distort the signal any more than with the car engine turned OFF, whereas driving in city traffic results in a lowered detection rate due to the driver's heavier movements. To enable robust and reliable estimation of heart rate, an algorithm is presented (based on principal component analysis) to detect and discard time intervals with artifacts. This, then, allows a reliable estimation of heart rate of up to 61% in city traffic and up to 86% on the highway: as a percentage of the total driving period with at least four consecutive QRS complexes.

  10. Performance of the DTL electrode compared to the jet contact lens electrode in clinical testing.

    Science.gov (United States)

    Yin, Hang; Pardue, Machelle T

    2004-01-01

    To compare the recording characteristics of the DTL fiber and Jet contact lens electrodes, ERG responses were recorded from 20 normal subjects using the ISCEV standard clinical protocol. In each subject, the DTL electrode was placed in the right eye and the Jet contact lens in the left eye after 30 min of dark-adaptation. After presenting standard dark- and light-adapted stimuli, each response was analyzed for a- and b-wave amplitude and implicit time. Each subject was then asked to rate the comfort of each electrode. Responses recorded with the DTL are larger and faster for the dark-adapted dim white and red flashes. In contrast, the Jet electrode records larger responses for the dark-adapted standard flash and light-adapted flashes. Of these differences, only the standard flash is statistically significant. However, overall the DTL electrode has greater variability than the Jet electrode across all recordings. The DTL and Jet electrodes cannot be used interchangeably as demonstrated by a Bland and Altman analysis of agreement. Thus, separate normative values need to be collected for each type of electrode to accurately assess retinal function. Based on the comfort assessment of the two electrodes, the subjects preferred the DTL electrode over the Jet electrode. Due to the superior comfort level of the DTL and its similarities to the Jet contact lens electrode in ERG recordings, the DTL electrode appears to be a good alternative to the Jet electrode in routine clinical testing when used with the appropriate normative values.

  11. A Simple Method for Guaranteeing ECG Quality in Real-Time Wavelet Lossy Coding

    Directory of Open Access Journals (Sweden)

    Alesanco Álvaro

    2007-01-01

    Full Text Available Guaranteeing ECG signal quality in wavelet lossy compression methods is essential for clinical acceptability of reconstructed signals. In this paper, we present a simple and efficient method for guaranteeing reconstruction quality measured using the new distortion index wavelet weighted PRD (WWPRD, which reflects in a more accurate way the real clinical distortion of the compressed signal. The method is based on the wavelet transform and its subsequent coding using the set partitioning in hierarchical trees (SPIHT algorithm. By thresholding the WWPRD in the wavelet transform domain, a very precise reconstruction error can be achieved thus enabling to obtain clinically useful reconstructed signals. Because of its computational efficiency, the method is suitable to work in a real-time operation, thus being very useful for real-time telecardiology systems. The method is extensively tested using two different ECG databases. Results led to an excellent conclusion: the method controls the quality in a very accurate way not only in mean value but also with a low-standard deviation. The effects of ECG baseline wandering as well as noise in compression are also discussed. Baseline wandering provokes negative effects when using WWPRD index to guarantee quality because this index is normalized by the signal energy. Therefore, it is better to remove it before compression. On the other hand, noise causes an increase in signal energy provoking an artificial increase of the coded signal bit rate. Clinical validation by cardiologists showed that a WWPRD value of 10 preserves the signal quality and thus they recommend this value to be used in the compression system.

  12. A Simple Method for Guaranteeing ECG Quality in Real-Time Wavelet Lossy Coding

    Directory of Open Access Journals (Sweden)

    José García

    2007-01-01

    Full Text Available Guaranteeing ECG signal quality in wavelet lossy compression methods is essential for clinical acceptability of reconstructed signals. In this paper, we present a simple and efficient method for guaranteeing reconstruction quality measured using the new distortion index wavelet weighted PRD (WWPRD, which reflects in a more accurate way the real clinical distortion of the compressed signal. The method is based on the wavelet transform and its subsequent coding using the set partitioning in hierarchical trees (SPIHT algorithm. By thresholding the WWPRD in the wavelet transform domain, a very precise reconstruction error can be achieved thus enabling to obtain clinically useful reconstructed signals. Because of its computational efficiency, the method is suitable to work in a real-time operation, thus being very useful for real-time telecardiology systems. The method is extensively tested using two different ECG databases. Results led to an excellent conclusion: the method controls the quality in a very accurate way not only in mean value but also with a low-standard deviation. The effects of ECG baseline wandering as well as noise in compression are also discussed. Baseline wandering provokes negative effects when using WWPRD index to guarantee quality because this index is normalized by the signal energy. Therefore, it is better to remove it before compression. On the other hand, noise causes an increase in signal energy provoking an artificial increase of the coded signal bit rate. Clinical validation by cardiologists showed that a WWPRD value of 10% preserves the signal quality and thus they recommend this value to be used in the compression system.

  13. [ECG abnormalities in the MONICA Gent-Charleroi study population].

    Science.gov (United States)

    De Backer, G

    1989-01-01

    In a survey of a random sample of the adult population (aged 25-64 yr) from Ghent and Charleroi (n = 1693), 103 (6.1%) showed ECG-abnormalities suggestive of coronary heart disease (Minnesota code I, IV, or V); prevalence was equal in men (6.2%) as in women (6.0%). In men, 30% of ECG-abnormalities suggested an old myocardial infarction as compared to 23.4% in women. Men with abnormal ECG had a positive history of acute myocardial infarction in 23%, as compared to 23.4% in women. Multivariate discriminant function analysis shows that men with abnormal ECG are older, have a higher systolic blood pressure and were more often married. Women with ECG abnormalities were significantly older, had a lower HDL-level and were less educated. So, although the prevalence of ECG abnormalities is almost similar between sexes, they correlate differently with antecedents of infarction and are poorly related to different sets of risk factors in men as compared to women.

  14. Live ECG readings using Google Glass in emergency situations.

    Science.gov (United States)

    Schaer, Roger; Salamin, Fanny; Jimenez Del Toro, Oscar Alfonso; Atzori, Manfredo; Muller, Henning; Widmer, Antoine

    2015-01-01

    Most sudden cardiac problems require rapid treatment to preserve life. In this regard, electrocardiograms (ECG) shown on vital parameter monitoring systems help medical staff to detect problems. In some situations, such monitoring systems may display information in a less than convenient way for medical staff. For example, vital parameters are displayed on large screens outside the field of view of a surgeon during cardiac surgery. This may lead to losing time and to mistakes when problems occur during cardiac operations. In this paper we present a novel approach to display vital parameters such as the second derivative of the ECG rhythm and heart rate close to the field of view of a surgeon using Google Glass. As a preliminary assessment, we run an experimental study to verify the possibility for medical staff to identify abnormal ECG rhythms from Google Glass. This study compares 6 ECG rhythms readings from a 13.3 inch laptop screen and from the prism of Google Glass. Seven medical residents in internal medicine participated in the study. The preliminary results show that there is no difference between identifying these 6 ECG rhythms from the laptop screen versus Google Glass. Both allow close to perfect identification of the 6 common ECG rhythms. This shows the potential of connected glasses such as Google Glass to be useful in selected medical applications.

  15. Two surgeons and the ECG-a double blind study

    Institute of Scientific and Technical Information of China (English)

    Ulf Martin Schilling

    2012-01-01

    Objective: To assess the capability of operating abdominal and orthopaedic surgeons to analyze a set of standardized ECG. Methods: Twenty operating abdominal and orthopaedic surgeons at a university hospital were included. Each participant analyzed a set of five standardized ECG with an answering scheme for eight different items, giving a maximum score of 40. The answers were matched according to specialty and experience of the doctors of less than 5 years, between 5 and 10 years or more than 10 years. The reference standard was set by two independent consultants in cardiology. Results: The mean overall score was 25.25 (63.13%±4.78%) varying between 38 (95%) and 20(50%). Abdominal surgeons performed a mean score of 27.625 (69.06%±9.53%), and orthopaedic surgeons 23.67 points (59.17%±3.69%). The difference between the performance of abdominal and orthopaedic surgeons was not significant (P=0.09). 20/20 surgeons identified ST-elevation and no surgeon accepted the ECG showing acute ST-elevation myocardial infarction as normal. Conclusions: Abdominal and orthopaedic surgeons provided an answering scheme are able to interprete the ECG and identify both the normal and the ECG showing life-threatening pathology. The hypothesis that surgeons were unable to interprete the ECG must be rejected.

  16. e-SCP-ECG+ Protocol: An Expansion on SCP-ECG Protocol for Health Telemonitoring—Pilot Implementation

    Directory of Open Access Journals (Sweden)

    George J. Mandellos

    2010-01-01

    Full Text Available Standard Communication Protocol for Computer-assisted Electrocardiography (SCP-ECG provides standardized communication among different ECG devices and medical information systems. This paper extends the use of this protocol in order to be included in health monitoring systems. It introduces new sections into SCP-ECG structure for transferring data for positioning, allergies, and five additional biosignals: noninvasive blood pressure (NiBP, body temperature (Temp, Carbon dioxide (CO2, blood oxygen saturation (SPO2, and pulse rate. It also introduces new tags in existing sections for transferring comprehensive demographic data. The proposed enhanced version is referred to as e-SCP-ECG+ protocol. This paper also considers the pilot implementation of the new protocol as a software component in a Health Telemonitoring System.

  17. Application of Holter ECG Signal Analysis Based on Wavelet and Data Mining Technique

    Institute of Scientific and Technical Information of China (English)

    余辉; 谢远国; 周仲兴; 吕扬生

    2004-01-01

    A new model based on dyadic differential wavelet was developed for detecting the R peak in Holter ECG signal according to the design of data mining. The Mallat recursive filter algorithm was introduced to calculate wavelet and optimize the detection algorithm which is based on the equivalent filter technique. The detection algorithm has been verified by MIT arrhythmia database with a high efficiency of 99%. After optimization,the algorithm was put into clinical experiment and tested in the Air Force Hospital in Tianjin for about two months. After about 108 hearts beating test of more than 100 patients, the total efficient detection rate has reached 97%. Now this algorithm module has been applied in business software and shows perfect performance under the complex conditions such as the inversion of heart beating, the falling off of the electrodes, the excursion of base line and so on.

  18. Technical note: Electrocardiogram electrode repositioning for 320-row coronary CT angiography in patients with regular and recurrent premature ventricular contractions.

    Science.gov (United States)

    Kondo, Takeshi; Matsutani, Hideyuki; Groarke, John; Takamura, Kazuhisa; Fujimoto, Shinichiro; Rybicki, Frank J; Kumamaru, Kanako K

    2014-01-01

    Arrhythmias can compromise image quality and increase radiation exposure during coronary CT angiography (CTA). However, premature ventricular contractions (PVCs) can occur in a predictable recurrent and regular pattern (ie, bigeminy, trigeminy, quadrigeminy) with post-PVC compensatory pauses. Electrocardiographic (ECG) electrode repositioning can achieve relative amplification of the R waves of PVCs compared with R waves of sinus beats. This technical note describes how simple ECG electrode repositioning, combined with an absolute-delay strategy, facilitated selective R waves of PVC ECG triggering of image acquisition in 6 patients with PVC bigeminy or quadrigeminy at the time of 320-row coronary CTA. All 6 studies were single heartbeat acquisition scans with excellent image quality and a median effective radiation dose of 2.9 mSv (interquartile range, 2.1-3.8 mSv). Standard ECG electrode positions used for 2 patients with PVC bigeminy undergoing coronary CTA were associated with an acquisition over 2 heartbeats and effective radiation doses of 6.8 and 10.3 mSv, respectively. In conclusion, ECG electrode repositioning combined with an absolute-delay strategy for regularly recurring PVCs, such as ventricular bigeminy, facilitates high image quality and lower radiation dose during coronary CTA. This simple and straightforward technique can be considered for all patients with regular and recurrent PVCs undergoing coronary CTA.

  19. Normally Off ECG SoC With Non-Volatile MCU and Noise Tolerant Heartbeat Detector.

    Science.gov (United States)

    Izumi, Shintaro; Yamashita, Ken; Nakano, Masanao; Yoshimoto, Shusuke; Nakagawa, Tomoki; Nakai, Yozaburo; Kawaguchi, Hiroshi; Kimura, Hiromitsu; Marumoto, Kyoji; Fuchikami, Takaaki; Fujimori, Yoshikazu; Nakajima, Hiroshi; Shiga, Toshikazu; Yoshimoto, Masahiko

    2015-10-01

    This paper describes an electrocardiograph (ECG) monitoring SoC using a non-volatile MCU (NVMCU) and a noise-tolerant instantaneous heartbeat detector. The novelty of this work is the combination of the non-volatile MCU for normally off computing and a noise-tolerant-QRS (heartbeat) detector to achieve both low-power and noise tolerance. To minimize the stand-by current of MCU, a non-volatile flip-flop and a 6T-4C NVRAM are used. Proposed plate-line charge-share and bit-line non-precharge techniques also contribute to mitigate the active power overhead of 6T-4C NVRAM. The proposed accurate heartbeat detector uses coarse-fine autocorrelation and a template matching technique. Accurate heartbeat detection also contributes system-level power reduction because the active ratio of ADC and digital block can be reduced using heartbeat prediction. Measurement results show that the fully integrated ECG-SoC consumes 6.14 μ A including 1.28- μA non-volatile MCU and 0.7- μA heartbeat detector.

  20. Standard-compliant real-time transmission of ECGs: harmonization of ISO/IEEE 11073-PHD and SCP-ECG.

    Science.gov (United States)

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2009-01-01

    Ambient assisted living and integrated care in an aging society is based on the vision of the lifelong Electronic Health Record calling for HealthCare Information Systems and medical device interoperability. For medical devices this aim can be achieved by the consistent implementation of harmonized international interoperability standards. The ISO/IEEE 11073 (x73) family of standards is a reference standard for medical device interoperability. In its Personal Health Device (PHD) version several devices have been included, but an ECG device specialization is not yet available. On the other hand, the SCP-ECG standard for short-term diagnostic ECGs (EN1064) has been recently approved as an international standard ISO/IEEE 11073-91064:2009. In this paper, the relationships between a proposed x73-PHD model for an ECG device and the fields of the SCP-ECG standard are investigated. A proof-of-concept implementation of the proposed x73-PHD ECG model is also presented, identifying open issues to be addressed by standards development for the wider interoperability adoption of x73-PHD standards.

  1. Usefulness of ST elevation score by using vector-projected virtual 187-channel ECG for risk stratification in patients with Brugada-type ECG pattern

    Directory of Open Access Journals (Sweden)

    Shoko Ishikawa

    2012-08-01

    Conclusion: The ST elevation score in VP-ECG objectively documented the degree of ST elevation in surface ECG in Brugada-type ECG patterns. The ST-elevation score might be useful for risk stratification in patients with asymptomatic Brugada syndrome.

  2. An adaptive Kalman filter for ECG signal enhancement.

    Science.gov (United States)

    Vullings, Rik; de Vries, Bert; Bergmans, Jan W M

    2011-04-01

    The ongoing trend of ECG monitoring techniques to become more ambulatory and less obtrusive generally comes at the expense of decreased signal quality. To enhance this quality, consecutive ECG complexes can be averaged triggered on the heartbeat, exploiting the quasi-periodicity of the ECG. However, this averaging constitutes a tradeoff between improvement of the SNR and loss of clinically relevant physiological signal dynamics. Using a bayesian framework, in this paper, a sequential averaging filter is developed that, in essence, adaptively varies the number of complexes included in the averaging based on the characteristics of the ECG signal. The filter has the form of an adaptive Kalman filter. The adaptive estimation of the process and measurement noise covariances is performed by maximizing the bayesian evidence function of the sequential ECG estimation and by exploiting the spatial correlation between several simultaneously recorded ECG signals, respectively. The noise covariance estimates thus obtained render the filter capable of ascribing more weight to newly arriving data when these data contain morphological variability, and of reducing this weight in cases of no morphological variability. The filter is evaluated by applying it to a variety of ECG signals. To gauge the relevance of the adaptive noise-covariance estimation, the performance of the filter is compared to that of a Kalman filter with fixed, (a posteriori) optimized noise covariance. This comparison demonstrates that, without using a priori knowledge on signal characteristics, the filter with adaptive noise estimation performs similar to the filter with optimized fixed noise covariance, favoring the adaptive filter in cases where no a priori information is available or where signal characteristics are expected to fluctuate.

  3. iElectrodes: A Comprehensive Open-Source Toolbox for Depth and Subdural Grid Electrode Localization

    Science.gov (United States)

    Blenkmann, Alejandro O.; Phillips, Holly N.; Princich, Juan P.; Rowe, James B.; Bekinschtein, Tristan A.; Muravchik, Carlos H.; Kochen, Silvia

    2017-01-01

    The localization of intracranial electrodes is a fundamental step in the analysis of invasive electroencephalography (EEG) recordings in research and clinical practice. The conclusions reached from the analysis of these recordings rely on the accuracy of electrode localization in relationship to brain anatomy. However, currently available techniques for localizing electrodes from magnetic resonance (MR) and/or computerized tomography (CT) images are time consuming and/or limited to particular electrode types or shapes. Here we present iElectrodes, an open-source toolbox that provides robust and accurate semi-automatic localization of both subdural grids and depth electrodes. Using pre- and post-implantation images, the method takes 2–3 min to localize the coordinates in each electrode array and automatically number the electrodes. The proposed pre-processing pipeline allows one to work in a normalized space and to automatically obtain anatomical labels of the localized electrodes without neuroimaging experts. We validated the method with data from 22 patients implanted with a total of 1,242 electrodes. We show that localization distances were within 0.56 mm of those achieved by experienced manual evaluators. iElectrodes provided additional advantages in terms of robustness (even with severe perioperative cerebral distortions), speed (less than half the operator time compared to expert manual localization), simplicity, utility across multiple electrode types (surface and depth electrodes) and all brain regions. PMID:28303098

  4. Validation of PC-based sound card with Biopac for digitalization of ECG recording in short-term HRV analysis

    Directory of Open Access Journals (Sweden)

    K Maheshkumar

    2016-01-01

    Full Text Available Background: Heart rate variability (HRV analysis is a simple and noninvasive technique capable of assessing autonomic nervous system modulation on heart rate (HR in healthy as well as disease conditions. The aim of the present study was to compare (validate the HRV using a temporal series of electrocardiograms (ECG obtained by simple analog amplifier with PC-based sound card (audacity and Biopac MP36 module. Materials and Methods: Based on the inclusion criteria, 120 healthy participants, including 72 males and 48 females, participated in the present study. Following standard protocol, 5-min ECG was recorded after 10 min of supine rest by Portable simple analog amplifier PC-based sound card as well as by Biopac module with surface electrodes in Leads II position simultaneously. All the ECG data was visually screened and was found to be free of ectopic beats and noise. RR intervals from both ECG recordings were analyzed separately in Kubios software. Short-term HRV indexes in both time and frequency domain were used. Results: The unpaired Student′s t-test and Pearson correlation coefficient test were used for the analysis using the R statistical software. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV. Correlation analysis revealed perfect positive correlation (r = 0.99, P < 0.001 between the values in time and frequency domain obtained by the devices. Conclusion: On the basis of the results of the present study, we suggest that the calculation of HRV values in the time and frequency domains by RR series obtained from the PC-based sound card is probably as reliable as those obtained by the gold standard Biopac MP36.

  5. Fast multi-scale feature fusion for ECG heartbeat classification

    Science.gov (United States)

    Ai, Danni; Yang, Jian; Wang, Zeyu; Fan, Jingfan; Ai, Changbin; Wang, Yongtian

    2015-12-01

    Electrocardiogram (ECG) is conducted to monitor the electrical activity of the heart by presenting small amplitude and duration signals; as a result, hidden information present in ECG data is difficult to determine. However, this concealed information can be used to detect abnormalities. In our study, a fast feature-fusion method of ECG heartbeat classification based on multi-linear subspace learning is proposed. The method consists of four stages. First, baseline and high frequencies are removed to segment heartbeat. Second, as an extension of wavelets, wavelet-packet decomposition is conducted to extract features. With wavelet-packet decomposition, good time and frequency resolutions can be provided simultaneously. Third, decomposed confidences are arranged as a two-way tensor, in which feature fusion is directly implemented with generalized N dimensional ICA (GND-ICA). In this method, co-relationship among different data information is considered, and disadvantages of dimensionality are prevented; this method can also be used to reduce computing compared with linear subspace-learning methods (PCA). Finally, support vector machine (SVM) is considered as a classifier in heartbeat classification. In this study, ECG records are obtained from the MIT-BIT arrhythmia database. Four main heartbeat classes are used to examine the proposed algorithm. Based on the results of five measurements, sensitivity, positive predictivity, accuracy, average accuracy, and t-test, our conclusion is that a GND-ICA-based strategy can be used to provide enhanced ECG heartbeat classification. Furthermore, large redundant features are eliminated, and classification time is reduced.

  6. Electroconvulsive therapy-induced ECG changes simulating a myocardial infarction.

    Science.gov (United States)

    Gould, L; Gopalaswamy, C; Chandy, F; Kim, B

    1983-09-01

    Electroconvulsive therapy (ECT) can produce various cardiac arrhythmias; however, to our knowledge, no other alterations have been described in the ECG. A 75-year-old woman was admitted to the Methodist Hospital in Brooklyn, NY, because of depression. She had had no cardiac symptoms and had been in good health. She was not receiving any medications. Physical examination showed no abnormalities. Findings from the routine laboratory tests, a chest roentgenogram, and the initial ECG were normal. In view of the severe depression, a series of ECTs were given to the patient during a two-week period. A repeated ECG showed deep T-wave inversions in leads I, II, III, aVF, and V1 to V6. The patient was completely asymptomatic. Serial enzyme determinations were normal. A brain scan, gated-pool scan, computed tomography scan of the head, and a technetium Tc 99m pyrophosphate scan were all normal. Serial ECGs showed a persistence of the deep T-wave inversions. There were no QRS changes. There was no evidence of a cerebral vascular accident or pericarditis. The T-wave changes in our patient were not due to a myocardial infarction. Thus, ECT can produce striking T-wave abnormalities in the ECG that can simulate an acute myocardial infarction.

  7. Shannon's Energy Based Algorithm in ECG Signal Processing

    Science.gov (United States)

    2017-01-01

    Physikalisch-Technische Bundesanstalt (PTB) database is electrocardiograms (ECGs) set from healthy volunteers and patients with different heart diseases. PTB is provided for research and teaching purposes by National Metrology Institute of Germany. The analysis method of complex QRS in ECG signals for diagnosis of heart disease is extremely important. In this article, a method on Shannon energy (SE) in order to detect QRS complex in 12 leads of ECG signal is provided. At first, this algorithm computes the Shannon energy (SE) and then makes an envelope of Shannon energy (SE) by using the defined threshold. Then, the signal peaks are determined. The efficiency of the algorithm is tested on 70 cases. Of all 12 standard leads, ECG signals include 840 leads of the PTB Diagnostic ECG Database (PTBDB). The algorithm shows that the Shannon energy (SE) sensitivity is equal to 99.924%, the detection error rate (DER) is equal to 0.155%, Positive Predictivity (+P) is equal to 99.922%, and Classification Accuracy (Acc) is equal to 99.846%.

  8. A system for intelligent home care ECG upload and priorisation.

    Science.gov (United States)

    D'Angelo, Lorenzo T; Tarita, Eugeniu; Zywietz, Tosja K; Lueth, Tim C

    2010-01-01

    In this contribution, a system for internet based, automated home care ECG upload and priorisation is presented for the first time. It unifies the advantages of existing telemonitoring ECG systems adding functionalities such as automated priorisation and usability for home care. Chronic cardiac diseases are a big group in the geriatric field. Most of them can be easily diagnosed with help of an electrocardiogram. A frequent or long-term ECG analysis allows early diagnosis of e.g. a cardiac infarction. Nevertheless, patients often aren't willing to visit a doctor for prophylactic purposes. Possible solutions of this problem are home care devices, which are used to investigate patients at home without the presence of a doctor on site. As the diffusion of such systems leads to a huge amount of data which has to be managed and evaluated, the presented approach focuses on an easy to use software for ECG upload from home, a web based management application and an algorithm for ECG preanalysis and priorisation.

  9. Effect of ECG filter settings on J-waves.

    Science.gov (United States)

    Nakagawa, Mikiko; Tsunemitsu, Chie; Katoh, Sayo; Kamiyama, Yukari; Sano, Nario; Ezaki, Kaori; Miyazaki, Hiroko; Teshima, Yasushi; Yufu, Kunio; Takahashi, Naohiko; Saikawa, Tetsunori

    2014-01-01

    While J-waves were observed in healthy populations, variations in their reported incidence may be partly explicable by the ECG filter setting. We obtained resting 12-lead ECG recordings in 665 consecutive patients and enrolled 112 (56 men, 56 women, mean age 59.3±16.1years) who manifested J-waves on ECGs acquired with a 150-Hz low-pass filter. We then studied the J-waves on individual ECGs to look for morphological changes when 25-, 35-, 75-, 100-, and 150Hz filters were used. The notching observed with the 150-Hz filter changed to slurring (42%) or was eliminated (28%) with the 25-Hz filter. Similarly, the slurring seen with the 150-Hz filter was eliminated on 71% of ECGs recorded with the 25-Hz filter. The amplitude of J-waves was significantly lower with 25- and 35-Hz than 75-, 100-, and 150-Hz filters (pfilter setting significantly affects the J-wave morphology. © 2013.

  10. PIC microcontroller-based RF wireless ECG monitoring system.

    Science.gov (United States)

    Oweis, R J; Barhoum, A

    2007-01-01

    This paper presents a radio-telemetry system that provides the possibility of ECG signal transmission from a patient detection circuit via an RF data link. A PC then receives the signal through the National Instrument data acquisition card (NIDAQ). The PC is equipped with software allowing the received ECG signals to be saved, analysed, and sent by email to another part of the world. The proposed telemetry system consists of a patient unit and a PC unit. The amplified and filtered ECG signal is sampled 360 times per second, and the A/D conversion is performed by a PIC16f877 microcontroller. The major contribution of the final proposed system is that it detects, processes and sends patients ECG data over a wireless RF link to a maximum distance of 200 m. Transmitted ECG data with different numbers of samples were received, decoded by means of another PIC microcontroller, and displayed using MATLAB program. The designed software is presented in a graphical user interface utility.

  11. Shannon's Energy Based Algorithm in ECG Signal Processing.

    Science.gov (United States)

    Beyramienanlou, Hamed; Lotfivand, Nasser

    2017-01-01

    Physikalisch-Technische Bundesanstalt (PTB) database is electrocardiograms (ECGs) set from healthy volunteers and patients with different heart diseases. PTB is provided for research and teaching purposes by National Metrology Institute of Germany. The analysis method of complex QRS in ECG signals for diagnosis of heart disease is extremely important. In this article, a method on Shannon energy (SE) in order to detect QRS complex in 12 leads of ECG signal is provided. At first, this algorithm computes the Shannon energy (SE) and then makes an envelope of Shannon energy (SE) by using the defined threshold. Then, the signal peaks are determined. The efficiency of the algorithm is tested on 70 cases. Of all 12 standard leads, ECG signals include 840 leads of the PTB Diagnostic ECG Database (PTBDB). The algorithm shows that the Shannon energy (SE) sensitivity is equal to 99.924%, the detection error rate (DER) is equal to 0.155%, Positive Predictivity (+P) is equal to 99.922%, and Classification Accuracy (Acc) is equal to 99.846%.

  12. ECG-Derived Respiration and Instantaneous Frequency based on the Synchrosqueezing Transform: Application to Patients with Atrial Fibrillation

    CERN Document Server

    Yi-Hsin, Chan; Shu-Shya, Hseu; Chi-Tai, Kuo; Yung-Hsin, Yeh

    2011-01-01

    The acquisition of information about respiratory patterns without directly recording the respiratory signals would be beneficial in many clinical settings. The electrocardiogram (ECG)-derived respiration (EDR) algorithm, which derives the respiratory pattern by using the information encoded in ECG signals, enables data acquisition in this manner. However, the traditional EDR algorithm cannot be used in patients with atrial fibrillation (AF) because they have highly irregular heart rates. In this paper, we first provide a definition of ideal instantaneous frequency (IIF) of respiratory signals and then describe how a novel time-frequency representation technique referred to as the Synchrosqueezing transform (SST) was used for the accurate estimation of the IIF of respiratory signals, i.e., SST-IF. Then, we introduce a new EDR algorithm based on the evaluation of the SST-IF. We tested the applicability of our new EDR algorithm in patients with comorbid cardiovascular diseases, most of which were complicated by ...

  13. A new technique of ECG analysis and its application to evaluation of disorders during ventricular tachycardia

    Energy Technology Data Exchange (ETDEWEB)

    Moskalenko, A.V. [Institute of Theoretical and Experimental Biophysics RAS, Institutskaya Street, 3, Pushchino 142290 (Russian Federation)], E-mail: info@avmoskalenko.ru; Rusakov, A.V. [Institute of Theoretical and Experimental Biophysics RAS, Institutskaya Street, 3, Pushchino 142290 (Russian Federation); Elkin, Yu.E. [Institute of Mathematical Problems of Biology RAS, Institutskaya Street, 4, Pushchino 142290 (Russian Federation)

    2008-04-15

    We propose a new technique of ECG analysis to characterize the properties of polymorphic ventricular arrhythmias, potentially life-threatening disorders of cardiac activation. The technique is based on extracting two indices from the ECG fragment. The result is a new detailed quantitative description of polymorphic ECGs. Our observations suggest that the proposed ECG processing algorithm provides information that supplements the traditional visual ECG analysis. The estimates of ECG variation in this study reveal some unexpected details of ventricular activation dynamics, which are possibly useful for diagnosing cardiac rhythm disturbances.

  14. ECG compression: evaluation of FFT, DCT, and WT performance.

    Science.gov (United States)

    GholamHosseini, H; Nazeran, H; Moran, B

    1998-12-01

    This work investigates a set of ECG data compression schemes to compare their performances in compressing and preparing ECG signals for automatic cardiac arrhythmia classification. These schemes are based on transform methods such as fast Fourier transform (FFT), discrete cosine transform (DCT), wavelet transform (WT), and their combinations. Each specific transform is applied to a pre-selected data segment from the MIT-BIH database and then compression is performed in the new domain. These transformation methods are known as an important class of ECG compression techniques. The WT has been shown as the most efficient method for further improvement. A compression ratio of 7.98 to 1 has been achieved with a percent of root mean square difference (PRD) of 0.25%, indicating that the wavelet compression technique offers the best performance over the other evaluated methods.

  15. On ECG reconstruction using weighted-compressive sensing.

    Science.gov (United States)

    Zonoobi, Dornoosh; Kassim, Ashraf A

    2014-06-01

    The potential of the new weighted-compressive sensing approach for efficient reconstruction of electrocardiograph (ECG) signals is investigated. This is motivated by the observation that ECG signals are hugely sparse in the frequency domain and the sparsity changes slowly over time. The underlying idea of this approach is to extract an estimated probability model for the signal of interest, and then use this model to guide the reconstruction process. The authors show that the weighted-compressive sensing approach is able to achieve reconstruction performance comparable with the current state-of-the-art discrete wavelet transform-based method, but with substantially less computational cost to enable it to be considered for use in the next generation of miniaturised wearable ECG monitoring devices.

  16. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  17. ECG-Based Measurements of Drug-induced Repolarization Changes

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed

    The purpose of this thesis is to investigate the abnormal repolarization both in the cellular and the surface ECG along with their relationship. It has been identified that the certain morphological changes of the monophasic action potential are predictor of TdP arrhythmia. Therefore the proporti......The purpose of this thesis is to investigate the abnormal repolarization both in the cellular and the surface ECG along with their relationship. It has been identified that the certain morphological changes of the monophasic action potential are predictor of TdP arrhythmia. Therefore...... the proportional changes of the surface ECG which corresponds to the arrhythmia-triggering MAP morphology is warranted to increase the confidence of determining cardiotoxicity of drugs....

  18. Chaos control applied to cardiac rhythms represented by ECG signals

    Science.gov (United States)

    Borem Ferreira, Bianca; Amorim Savi, Marcelo; Souza de Paula, Aline

    2014-10-01

    The control of irregular or chaotic heartbeats is a key issue in cardiology. In this regard, chaos control techniques represent a good alternative since they suggest treatments different from those traditionally used. This paper deals with the application of the extended time-delayed feedback control method to stabilize pathological chaotic heart rhythms. Electrocardiogram (ECG) signals are employed to represent the cardiovascular behavior. A mathematical model is employed to generate ECG signals using three modified Van der Pol oscillators connected with time delay couplings. This model provides results that qualitatively capture the general behavior of the heart. Controlled ECG signals show the ability of the strategy either to control or to suppress the chaotic heart dynamics generating less-critical behaviors.

  19. Design and Implementation of Wearable ECG Monitoring Equipment%可穿戴心电监护设备设计与实现

    Institute of Scientific and Technical Information of China (English)

    祝宇虹; 牛群

    2016-01-01

    为了满足心脏病患者日益增长的心电监护需求,设计了一种可穿戴式的心电监护设备来满足患者日常生活的心电监护功能。设备设计包括硬件和软件2部分,硬件方面采用柔性织物电极、AD8232芯片和STM32微控制器实现对心电信号的采集、A/D转换和传输功能;软件方面借用小波变换在心电信号去噪和识别方面的优势,获得清晰的心电信号和心率,并实现对症状的初步诊断;最后设计了基于 LabVIEW平台的友好人机交互界面,可以直观、清楚的显示心电信号的实时波形,当前患者的R R间期和心率参数。利用本设备对几位志愿者进行测试,得到了良好的结果,可以实现患者日常心电监护。%In order to meet the growing demand of patients with heart diseases for ECG monitoring, this paper designs wearable ECG monitoring equipment to achieve the ECG monitoring function of daily life for patients.The equipment design comprises hardware and software design.In terms of hardware,the flexible fabric electrode,AD8232 chip and STM32 microcontroller are used to implement the functions of ECG signal acquisition,A/D conversion and transmission;In term of software,the advantages of the wavelet transformation in ECG signal denoising and identification are utilized to obtain a clear ECG signal and heart rate,and realize the preliminary diagnosis of the symptoms.Finally,a friendly human computer inter-action interface based on the LabVIEW platform can display real time ECG signal waveform,the current RR inter phase and the heart rate in patients intuitively and clearly.Several volunteers are tested with the equipment. Good results are obtained.The equipment can realize patients'daily ECG monitoring.

  20. Fault Tolerant Neural Network for ECG Signal Classification Systems

    Directory of Open Access Journals (Sweden)

    MERAH, M.

    2011-08-01

    Full Text Available The aim of this paper is to apply a new robust hardware Artificial Neural Network (ANN for ECG classification systems. This ANN includes a penalization criterion which makes the performances in terms of robustness. Specifically, in this method, the ANN weights are normalized using the auto-prune method. Simulations performed on the MIT ? BIH ECG signals, have shown that significant robustness improvements are obtained regarding potential hardware artificial neuron failures. Moreover, we show that the proposed design achieves better generalization performances, compared to the standard back-propagation algorithm.

  1. Left bundle branch block: a rare ECG manifestation of hyperkalemia

    Directory of Open Access Journals (Sweden)

    Venkata Madhav M

    2015-04-01

    Full Text Available A 20-year-old female patient with chronic kidney disease was brought to our emergency medical department with symptoms of pain in chest and abdomen, vomitings. Laboratory testing revealed serum potassium 7.7 mEq/L, serum creatinine 9.1 mg/dL. Electrocardiogram (ECG showed left bundle branch block (LBBB pattern with left axis deviation, tall T waves and ST elevation. Among ECG alterations in hyperkalemia, LBBB is rare and is being reported in our case.

  2. A novel method of fabricating carbon nanotubes-polydimethylsiloxane composite electrodes for electrocardiography.

    Science.gov (United States)

    Liu, Benyan; Chen, Yingmin; Luo, Zhangyuan; Zhang, Wenzan; Tu, Quan; Jin, Xun

    2015-01-01

    Polymer-based flexible electrodes are receiving much attention in medical applications due to their good wearing comfort. The current fabrication methods of such electrodes are not widely applied. In this study, polydimethylsiloxane (PDMS) and conductive additives of carbon nanotubes (CNTs) were employed to fabricate composite electrodes for electrocardiography (ECG). A three-step dispersion process consisting of ultrasonication, stirring, and in situ polymerization was developed to yield homogenous CNTs-PDMS mixtures. The CNTs-PDMS mixtures were used to fabricate CNTs-PDMS composite electrodes by replica technology. The influence of ultrasonication time and CNT concentration on polymer electrode performance was evaluated by impedance and ECG measurements. The signal amplitude of the electrodes prepared using an ultrasonication time of 12 h and CNT content of 5 wt% was comparable to that of commercial Ag/AgCl electrodes. The polymer electrodes were easily fabricated by conventional manufacturing techniques, indicating a potential advantage of reduced cost for mass production.

  3. Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method

    Directory of Open Access Journals (Sweden)

    Keyun Chen

    2016-09-01

    Full Text Available Micro-needle electrodes (MEs have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII, electromyography (EMG and electrocardiography (ECG recording. A magnetization-induced self-assembling method (MSM was developed to fabricate a microneedle array (MA. A MA coated with Ti/Au film was assembled as a ME. The fracture and insertion properties of ME were tested by experiments. The bio-signal recording performance of the ME was measured and compared with a typical commercial wet electrode (Ag/AgCl electrode. The results show that the MA self-assembled from the magnetic droplet array under the sum of gravitational surface tension and magnetic potential energies. The ME had good toughness and could easily pierce rabbit skin without being broken or buckling. When the compression force applied on the ME was larger than 2 N, ME could stably record EII, which was a lower value than that measured by Ag/AgCl electrodes. EMG signals collected by ME varied along with the contraction of biceps brachii muscle. ME could record static ECG signals with a larger amplitude and dynamic ECG signals with more distinguishable features in comparison with a Ag/AgCl electrode, therefore, ME is an alternative electrode for bio-signal monitoring in some specific situations.

  4. Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method.

    Science.gov (United States)

    Chen, Keyun; Ren, Lei; Chen, Zhipeng; Pan, Chengfeng; Zhou, Wei; Jiang, Lelun

    2016-09-20

    Micro-needle electrodes (MEs) have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII), electromyography (EMG) and electrocardiography (ECG) recording. A magnetization-induced self-assembling method (MSM) was developed to fabricate a microneedle array (MA). A MA coated with Ti/Au film was assembled as a ME. The fracture and insertion properties of ME were tested by experiments. The bio-signal recording performance of the ME was measured and compared with a typical commercial wet electrode (Ag/AgCl electrode). The results show that the MA self-assembled from the magnetic droplet array under the sum of gravitational surface tension and magnetic potential energies. The ME had good toughness and could easily pierce rabbit skin without being broken or buckling. When the compression force applied on the ME was larger than 2 N, ME could stably record EII, which was a lower value than that measured by Ag/AgCl electrodes. EMG signals collected by ME varied along with the contraction of biceps brachii muscle. ME could record static ECG signals with a larger amplitude and dynamic ECG signals with more distinguishable features in comparison with a Ag/AgCl electrode, therefore, ME is an alternative electrode for bio-signal monitoring in some specific situations.

  5. Power-line Interference Removal from ECG in Case of Power-line Frequency Variations

    Directory of Open Access Journals (Sweden)

    Todor Stoyanov

    2008-10-01

    Full Text Available The original version of the most successful approach for power-line (PL interference removal from ECG, called subtraction procedure, is based on linear segment detection in the signal and hardware synchronised analogue-to-digital conversion to cope with the PL frequency variations. However, this is not feasible for battery supplied devices and some computer-aided ECG systems. Recent improvements of the procedure apply software measurement of the frequency variations that allow a re-sampling of the contaminated signal with the rated PL frequency followed by interference removal and back re-sampling for restoration of the original time intervals. This study deals with a more accurate software frequency measurement and introduces a notch filtration as alternative to the procedure when no linear segments are encountered for long time, e.g. in cases of ventricular fibrillation or tachycardia. The result obtained with large PL frequency variations demonstrate very small errors, usually in the range of ± 20 μV for the subtraction procedure and ± 60 μV for the notch filtration, the last values strongly depending on the frequency contents of the QRS complexes.

  6. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    Directory of Open Access Journals (Sweden)

    Bohui Zhu

    2013-01-01

    Full Text Available This paper presents a novel maximum margin clustering method with immune evolution (IEMMC for automatic diagnosis of electrocardiogram (ECG arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias.

  7. Heart rhythm analysis using ECG recorded with a novel sternum based patch technology

    DEFF Research Database (Denmark)

    Saadi, Dorthe B.; Fauerskov, Inge; Osmanagic, Armin

    2013-01-01

    , reliable long-term ECG recordings. The device is designed for high compliance and low patient burden. This novel patch technology is CE approved for ambulatory ECG recording of two ECG channels on the sternum. This paper describes a clinical pilot study regarding the usefulness of these ECG signals...... for heart rhythm analysis. A clinical technician with experience in ECG interpretation selected 200 noise-free 7 seconds ECG segments from 25 different patients. These 200 ECG segments were evaluated by two medical doctors according to their usefulness for heart rhythm analysis. The first doctor considered...... 98.5% of the segments useful for rhythm analysis, whereas the second doctor considered 99.5% of the segments useful for rhythm analysis. The conclusion of this pilot study indicates that two channel ECG recorded on the sternum is useful for rhythm analysis and could be used as input to diagnosis...

  8. Antiequine chorionic gonadotropin (eCG) antibodies generated in goats treated with eCG for the induction of ovulation modulate the luteinizing hormone and follicle-stimulating hormone bioactivities of eCG differently.

    Science.gov (United States)

    Hervé, Virginie; Roy, François; Bertin, Jean; Guillou, Florian; Maurel, Marie-Christine

    2004-01-01

    In dairy goats, treatments associating a progestogen and the equine chorionic gonadotropin (eCG) are the easiest way to induce and synchronize estrus and ovulation and to permit artificial insemination (AI) and/or out of season breeding. From the first treatment, the injection of eCG induces, in some females, the production of anti-eCG antibodies (Abs) that will interfere with the effectiveness of subsequent treatments. These anti-eCG Abs delay the preovulatory LH surge and the ovulation time, leading to poor fertility of the treated females. In this study, by in vitro bioassays, we show that anti-eCG Abs can positively or negatively modulate the LH and/or FSH bioactivities of eCG. Moreover, the modulation level of eCG bioactivity does not depend on the anti-eCG Ab affinity for eCG, as shown by surface plasmon resonance technology. The specificity of anti-eCG Abs tested by competitive ELISA highlighted the importance of a glycan environment in the recognition mechanism, especially the sialic acids specific to eCG. The different effects of anti-eCG Abs on eCG bioactivities could be explained by two hypotheses. First, steric hindrance preventing the interaction of eCG with its receptors would explain the inhibitory effect of some anti-eCG Abs; second, a conformational change in eCG by anti-eCG Abs could induce inhibition or potentiation of eCG bioactivities. It is significant that these modulations of eCG bioactivities by anti-eCG Abs impact mainly on the FSH bioactivity of eCG, which is essential for ovarian stimulation and subsequent fertility after treatment and AI, and to a lesser extent on LH bioactivity.

  9. Development and Application of ECG Acquisition System Based on BMD101 Chip%基于BMD101芯片的心电采集器的开发和应用

    Institute of Scientific and Technical Information of China (English)

    王廷宇; 高军晖

    2015-01-01

    该文利用BMD101芯片,开发了一套心电测量系统。整个系统由心电数据采集及分析软件(运行在Android手机上)、BMD心电采集器、贴敷电极组成。利用这套系统,对人群进行心电测试,发现心率随年龄的变化规律。%In this paper,we use BMD101 chipA set of ECG measurement system is developed.(Running on Android)、 ECG acquisition、Electrode composition. Use of the system,ECG test for people,The change of heart rate with age.

  10. [Development of software of the 24-hour dynamic ECG monitoring and analyzing system].

    Science.gov (United States)

    An, Y; Fang, K R; Ren, C S

    2001-01-01

    This paper describes a PC-computer program of a digital remote ECG monitoring system. In addition to current monitor's capabilities of real time displaying of dynamic ECG wave, over-limit alarming, and so on, it has developed most functions of the Holter system, that are recording the data of ECG more than 24 hours, reviewing and analyzing the ECG data, and giving out reports.

  11. ECG baseline wander reduction using linear phase filters

    NARCIS (Netherlands)

    Alsté, van J.A.; Eck, van W.; Hermann, O.E.

    1986-01-01

    The continuous real time reduction of baseline wander is a considerable problem in electrocardiography during exercises. Our solution consists of spectral filtering. The legitimacy of high-pass filtering of the ECG by means of digital linear phase filters with a low cut-off frequency as high as the

  12. Thyroid hormones concentrations and ECG picture in the dog.

    Science.gov (United States)

    Pasławska, U; Noszczyk-Nowak, A; Kungl, K; Bioły, K; Popiel, J; Nicpoń, J

    2006-01-01

    Disorders of the thyroid gland activity are the most commonly encountered disturbances of endocrine origin in the dog. Hypo- or hyperthyroidism may disturb the function of the cardiovascular system and cause arrhythmias. The aim of this study was to evaluate the influence of thyroid gland activity on electrocardiogram (ECG) picture in the dog by comparing ECG curves of healthy dogs, dogs with hypothyroidism and dogs with cardiac insufficiency caused by endocardiosis of the mitral valve. The study was performed on 38 dogs, patients of the Department of Internal and Parasitic Diseases with Clinic for Horses, Dogs and Cats in Wrocław. The animals were assigned to 3 groups: Group I--control group, 13 clinically healthy dogs; Group II--14 dogs with diagnosed cardiac insufficiency caused by endocardiosis of the mitral valve; Group III--11 dogs with hypothyroidism. Clinical examination of the animals was conducted according to the following pattern: anamnesis, general clinical examination, cardiological examination (ECG, USG of the heart) and laboratory analysis (triacylglycerydes, cholesterol, T3, T4, FT4). In this study, the significant influence of thyroid gland activity on ECG picture of the evaluated dogs was found. In the dogs with hypothyroidism a decrease in the sino-atrial node activity was observed, which led to decreased heart rate. In dogs with hypothyroidism, the innerheart conduction was reduced, which was demonstrated by prolongation of the P wave, QRS complex and the QT interval.

  13. Disease Classification and Biomarker Discovery Using ECG Data

    Directory of Open Access Journals (Sweden)

    Rong Huang

    2015-01-01

    Full Text Available In the recent decade, disease classification and biomarker discovery have become increasingly important in modern biological and medical research. ECGs are comparatively low-cost and noninvasive in screening and diagnosing heart diseases. With the development of personal ECG monitors, large amounts of ECGs are recorded and stored; therefore, fast and efficient algorithms are called for to analyze the data and make diagnosis. In this paper, an efficient and easy-to-interpret procedure of cardiac disease classification is developed through novel feature extraction methods and comparison of classifiers. Motivated by the observation that the distributions of various measures on ECGs of the diseased group are often skewed, heavy-tailed, or multimodal, we characterize the distributions by sample quantiles which outperform sample means. Three classifiers are compared in application both to all features and to dimension-reduced features by PCA: stepwise discriminant analysis (SDA, SVM, and LASSO logistic regression. It is found that SDA applied to dimension-reduced features by PCA is the most stable and effective procedure, with sensitivity, specificity, and accuracy being 89.68%, 84.62%, and 88.52%, respectively.

  14. ECG classification and abnormality detection using cascade forward ...

    African Journals Online (AJOL)

    user

    This paper describes the use of MATLAB based artificial neural network tools for ... as well as tools to analyse the results, makes it a good option to solve this complex problem .... ECG & AMT Teacher's Source Book,2006, Government of Kerala, Department of ... and uses the artificial intelligence techniques in her research.

  15. Continuous control systems for non-contact ECG

    Science.gov (United States)

    Kodkin, Vladimir L.; Yakovleva, Galina V.; Smirnov, Alexey S.

    2017-03-01

    South Ural State University is still conducting the research work dedicated to innovations in biomedicine. Development of system for continuous control and diagnosis of the functional state in large groups of people is based on studies of non-contact ECG recording reported by the authors at the SPIE conference in 2016. The next stage of studies has been performed this year.

  16. Holter ECG monitoring of sympathovagal fluctuation during bronchoscopy.

    Science.gov (United States)

    Ali, Abdellah Hamed Khalil; Toba, Hiroaki; Sakiyama, Shoji; Yamamoto, Ryo; Takizawa, Hiromitsu; Kenzaki, Koichiro; Kondo, Kazuya; Tangoku, Akira

    2016-03-01

    The changes of autonomic nervous activity during bronchoscopic procedures are closely related to the development of cardiovascular complications. We aimed to evaluate the changes of autonomic nervous activity during bronchoscopic procedures using R-R interval variability from electrocardiograms (ECGs) obtained during diagnostic bronchoscopy. Twenty-four patients who underwent bronchoscopy were included. Continuous ECG was recorded prior to, during and after the bronchoscopic procedure. Time and frequency domain analyses of heart rate variability were performed. Heart rate increased significantly after pre-medication compared with that before pre-medication and increased further during bronchoscopy. The coefficient of variation (CVRR ) values after pre-medication and during bronchoscopy were significantly higher than those before pre-medication (P = 0.031 and P = 0.041, respectively). The low frequency (LF) power decreased during bronchoscopy. LF powers obtained after bronchoscopy were significantly lower than those obtained before bronchoscopy (P Holter ECG monitoring during diagnostic bronchoscopy was associated with activation of cardiac sympathetic and withdrawal of cardiac parasympathetic regulation, which may contribute to the occurrence of cardiac events during bronchoscopic procedures. So, Holter ECG monitoring during bronchoscopic procedures may confer reduction in cardiovascular events. © 2014 John Wiley & Sons Ltd.

  17. ECG-based heartbeat classification for arrhythmia detection: A survey.

    Science.gov (United States)

    Luz, Eduardo José da S; Schwartz, William Robson; Cámara-Chávez, Guillermo; Menotti, David

    2016-04-01

    An electrocardiogram (ECG) measures the electric activity of the heart and has been widely used for detecting heart diseases due to its simplicity and non-invasive nature. By analyzing the electrical signal of each heartbeat, i.e., the combination of action impulse waveforms produced by different specialized cardiac tissues found in the heart, it is possible to detect some of its abnormalities. In the last decades, several works were developed to produce automatic ECG-based heartbeat classification methods. In this work, we survey the current state-of-the-art methods of ECG-based automated abnormalities heartbeat classification by presenting the ECG signal preprocessing, the heartbeat segmentation techniques, the feature description methods and the learning algorithms used. In addition, we describe some of the databases used for evaluation of methods indicated by a well-known standard developed by the Association for the Advancement of Medical Instrumentation (AAMI) and described in ANSI/AAMI EC57:1998/(R)2008 (ANSI/AAMI, 2008). Finally, we discuss limitations and drawbacks of the methods in the literature presenting concluding remarks and future challenges, and also we propose an evaluation process workflow to guide authors in future works.

  18. Are ECG abnormalities in Noonan syndrome characteristic for the syndrome?

    NARCIS (Netherlands)

    Raaijmakers, R.; Noordam, C.; Noonan, J.A.; Croonen, E.A.; Burgt, C.J. van der; Draaisma, J.M.T.

    2008-01-01

    Of all patients with Noonan syndrome, 50-90% have one or more congenital heart defects. The most frequent occurring are pulmonary stenosis (PS) and hypertrophic cardiomyopathy. The electrocardiogram (ECG) of a patient with Noonan syndrome often shows a characteristic pattern, with a left axis deviat

  19. Cardiac Electrophysiology: Normal and Ischemic Ionic Currents and the ECG

    Science.gov (United States)

    Klabunde, Richard E.

    2017-01-01

    Basic cardiac electrophysiology is foundational to understanding normal cardiac function in terms of rate and rhythm and initiation of cardiac muscle contraction. The primary clinical tool for assessing cardiac electrical events is the electrocardiogram (ECG), which provides global and regional information on rate, rhythm, and electrical…

  20. ECG Monitoring in Cardiac Rehabilitation: Is It Needed?

    Science.gov (United States)

    Greenland, Philip; Pomilla, Paul V.

    1989-01-01

    Discusses the controversial use of continuous electrocardiogram (ECG) monitoring as a safety measure in cardiac rehabilitation exercise programs. Little evidence substantiates its value for all patients during exercise. In the absence of empirical evidence documenting the worth of this expensive procedure, it is recommended for use with high-risk…

  1. Confidential Data Hiding Using Wavlet Based Ecg Stegnography

    Directory of Open Access Journals (Sweden)

    Malashree K S

    2014-05-01

    Full Text Available With the growing number of aging population and a significant portion of that suffering from cardiac diseases, it is conceivable that remote ECG patient monitoring systems are expected to be widely used as Point-of-Care (PoC applications in hospitals around the world. Therefore, huge amount of ECG signal collected by Body Sensor Networks (BSNs from remote patients at homes will be transmitted along with other physiological readings such as blood pressure, temperature, glucose level etc. and diagnosed by those remote patient monitoring systems. It is utterly important that patient confidentiality is protected while data is being transmitted over the public network as well as when they are stored in hospital servers used by remote monitoring systems. In this project, a wavelet based steganography technique has been introduced which combines encryption and scrambling technique to protect patient confidential data. The proposed method allows ECG signal to hide its corresponding patient confidential data and other physiological information thus guaranteeing the integration between ECG and the rest.

  2. Late postoperative episodic and constant hypoxaemia and associated ECG abnormalities

    DEFF Research Database (Denmark)

    Rosenberg, J; Rasmussen, Verner; von Jessen, F

    1990-01-01

    heart rate increased 16 beat min-1 (P less than 0.001) and mean oxygen saturation (SaO2) decreased 2.6% (P less than 0.001) after operation. Episodic oxygen desaturation to less than 80% occurred in four patients before operation, but in 13 patients after operation (P less than 0.05). ECG abnormalities...

  3. ECG-cryptography and authentication in body area networks.

    Science.gov (United States)

    Zhang, Zhaoyang; Wang, Honggang; Vasilakos, Athanasios V; Fang, Hua

    2012-11-01

    Wireless body area networks (BANs) have drawn much attention from research community and industry in recent years. Multimedia healthcare services provided by BANs can be available to anyone, anywhere, and anytime seamlessly. A critical issue in BANs is how to preserve the integrity and privacy of a person's medical data over wireless environments in a resource efficient manner. This paper presents a novel key agreement scheme that allows neighboring nodes in BANs to share a common key generated by electrocardiogram (ECG) signals. The improved Jules Sudan (IJS) algorithm is proposed to set up the key agreement for the message authentication. The proposed ECG-IJS key agreement can secure data communications over BANs in a plug-n-play manner without any key distribution overheads. Both the simulation and experimental results are presented, which demonstrate that the proposed ECG-IJS scheme can achieve better security performance in terms of serval performance metrics such as false acceptance rate (FAR) and false rejection rate (FRR) than other existing approaches. In addition, the power consumption analysis also shows that the proposed ECG-IJS scheme can achieve energy efficiency for BANs.

  4. Diagnostic quality of time-averaged ECG-gated CT data

    NARCIS (Netherlands)

    Klein, A.; Oostveen, L.J.; Greuter, M.J.W.; Hoogeveen, Y.; Schultze Kool, L.J.; Slump, C.H.; Renema, W.K.J.; Samei, Ehsan; Hsieh, Jiang

    2009-01-01

    Purpose: ECG-gated CTA allows visualization of the aneurysm and stentgraft during the different phases of the cardiac cycle, although with a lower SNR per cardiac phase than without ECG gating using the same dose. In our institution, abdominal aortic aneurysm (AAA) is evaluated using non-ECG-gated C

  5. ECG Identification System Using Neural Network with Global and Local Features

    Science.gov (United States)

    Tseng, Kuo-Kun; Lee, Dachao; Chen, Charles

    2016-01-01

    This paper proposes a human identification system via extracted electrocardiogram (ECG) signals. Two hierarchical classification structures based on global shape feature and local statistical feature is used to extract ECG signals. Global shape feature represents the outline information of ECG signals and local statistical feature extracts the…

  6. Value of Automated ECG Interpretation in Diagnosis of Cardiac Disorders

    Directory of Open Access Journals (Sweden)

    Afsaneh Mohammadi

    2008-07-01

    Full Text Available Background: Electrocardiography (ECG is a valuable device in the assessment of cardiovascular diseases. Recent medical software developments such as the invention of modern automated ECG interpreters have greatly facilitated the work of electrocardiographers and cardiologists. We present our experience in the use of one such device in the routine reporting of 200 successive ECGs recorded in our Cardiac Care Unit and Cardiac Emergency Ward. Methods: The interpretations of 200 ECGs provided by the GE-digital ECG device were chosen and compared with those supplied by four cardiologists in a single blind manner. All statistical analyses were performed by using SPSS version 11.5 for windows. A p value of less than 0.05 was considered statistically significant.Results: There was a diagnostic match between the interpretations by the device and those by the cardiologists in 107 (53.5% cases as opposed to a diagnostic mismatch in 93 cases (46.5%. The matching rate in the interpretations of myocardial ischemic disorders was high, which means practically all the ischemic cases diagnosed by the device were confirmed by the cardiologists. Only in 12 cases myocardial infarction or ischemic changes were reported by the cardiologists, while they were missed by the device. As regards rhythm disorders, the sensitivity and specificity of the device were 67.7% and 75.7%, respectively. With respect to conductive disorders, the respective sensitivity and specificity of the device were 70% and 96.6%, respectively. Finally, in the case of structural disorders, the interpretations of the device were 92.8% sensitive and 83.3% specific.Conclusion: According to the results of our study and similar researches, it seems that the interpretations of an automated ECG device in diagnosing the ischemic and structural disorders of the heart are reliable. The device, however, should not be relied upon when assessing conduction disorders and dysrhythmias. We, therefore, recommend

  7. Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Ming-li; Lu, Bin; Han, Lei; Liu, Gang; Yu, Fang-Fang; Hou, Zhi-hui; Gao, Yang; Wang, Hong-yu; Jiang, Shiliang [Peking Union Medical College, Department of Radiology, Cardiovascular Institute and Fu Wai Hospital, Chinese Academy of Medical Sciences, Beijing (China); Wu, Run-ze; Johnson, Laura [CT Research Collaboration, Siemens Healthcare, Shang Hai (China); Yang, Yue-jin; Qiao, Shu-bin [Chinese Academy of Medical Sciences, Peking Union Medical College, Department of Cardiology, Division of Coronary Heart Disease, Cardiovascular Institute and Fu Wai Hospital, Beijing (China)

    2011-08-15

    To evaluate the diagnostic accuracy of dual-source CT (DSCT) prospective ECG-triggering coronary angiography in patients with different heart rate (HR). 103 patients with suspected coronary artery disease underwent DSCT prospective ECG-triggered coronary angiography and invasive coronary angiography (ICA). The patients were grouped by HR during CT scans: low HR ({<=}60 bpm, n = 34); medium HR (60 < HR {<=} 70 bpm, n = 36) and high HR (>70 bpm, n = 33). The sensitivity and specificity of DSCT in detecting {>=}50% stenosis were compared among subgroups where ICA was the gold standard. Image quality was scored using a 4-point scale. A total of 1,580 (95.9%) coronary artery segments were evaluable. Sensitivity and specificity were 82.8% and 98.4%, 88.3% and 98.7%, and 80.3% and 98.6% for different subgroups (all p > 0.05). The overall area under the curve of the receiver-operating characteristic analysis was 0.94. The image quality scores were 3.1 {+-} 0.3, 3.1 {+-} 0.3 and 3.0 {+-} 0.4 for subgroups (p > 0.05). The overall average effective radiation dose was 3.60 {+-} 1.60 mSv. DSCT coronary angiography with prospective ECG-triggering could be just as accurate in patients with medium to high HR compared to those with low HR. (orig.)

  8. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  9. Microcanonical processing methodology for ECG and intracardial potential: application to atrial fibrillation

    CERN Document Server

    Pont, Oriol; Yahia, Hussein; Derval, Nicolas; Hocini, Mélèze

    2012-01-01

    Cardiac diseases are the principal cause of human morbidity and mortality in the western world. The electric potential of the heart is a highly complex signal emerging as a result of nontrivial flow conduction, hierarchical structuring and multiple regulation mechanisms. Its proper accurate analysis becomes of crucial importance in order to detect and treat arrhythmias or other abnormal dynamics that could lead to life-threatening conditions. To achieve this, advanced nonlinear processing methods are needed: one example here is the case of recent advances in the Microcanonical Multiscale Formalism. The aim of the present paper is to recapitulate those advances and extend the analyses performed, specially looking at the case of atrial fibrillation. We show that both ECG and intracardial potential signals can be described in a model-free way as a fast dynamics combined with a slow dynamics. Sharp differences in the key parameters of the fast dynamics appear in different regimes of transition between atrial fibr...

  10. Comparative Analysis of the Discriminative Capacity of EEG, Two ECG-Derived and Respiratory Signals in Automatic Sleep Staging

    Directory of Open Access Journals (Sweden)

    Farideh Ebrahimi

    2017-01-01

    Full Text Available Highly accurate classification of sleep stages is possible based on EEG signals alone. However, reliable and high quality acquisition of these signals in the home environment is difficult. Instead, electrocardiogram (ECG and Respiratory (Res signals are easier to record and may offer a practical alternative for home monitoring of sleep. Therefore, automatic sleep staging was performed using ECG, Res (thoracic excursion and EEG signals from 31 nocturnal recordings of the Sleep Heart Health Study (SHHS polysomnography Database. Feature vectors were extracted from 0.5 min (standard epochs of sleep data by time-domain, frequency domain, time-frequency and nonlinear methods and optimized by using the Support Vector Machine-Recursive Feature Elimination (SVM-RFE method. These features were then classified by using a SVM. Classification based upon EEG features produced a Correct Classification Ratio CCR=0.92. In comparison, features derived from ECG signals alone, that is the combination of Heart Rate Variability (HRV, and ECG-Derived Respiration (EDR signals produced a CCR=0.54, while those features based on the combination of HRV and (thoracic Res signals resulted in a CCR=0.57. Overall comparison of the results based on standard epochs of EEG signals with those obtained from 5-minute (long epochs of cardiorespiratory signals, revealed that acceptable CCR=0.81 and discriminative capacity (Accuracy=89.32%, Specificity=92.88% and Sensitivity=78.64% were also achievable when using optimal feature sets derived from long epochs of the latter signals in sleep staging. In addition, it was observed that the presence of some artifacts (like bigeminy in the cardiorespiratory signals reduced the accuracy of automatic sleep staging more than the artifacts that contaminated the EEG signals.

  11. [Design of portable 12-lead digital ECG with low power consumption].

    Science.gov (United States)

    Sheng, Chuanguang; Yang, Cuiwei; Wu, Xiaomei; Wang, Yuanyuan; Qin, Yajie

    2013-11-01

    The design of portable and low power consumption 12-lead ECG is based on the digital signal processor TMS320C5515 and the analog front end ADS1298. The ADS1298 collects the ECG signals and deliver them to TMS320C5515. The preprocessed ECG signals are displayed real-time on a LCD and can be stored without compression for a long time. The ECG signals can also be sent to an up computer by a USB connector so that ECG data can be analyzed offline. The system has small volume, high precision and low power consumption.

  12. A vector-free ECG interpretation with P, QRS & T waves as unbalanced transitions between stable configurations of the heart electric field during P-R, S-T & T-P segments

    Science.gov (United States)

    2014-01-01

    Since cell membranes are weak sources of electrostatic fields, this ECG interpretation relies on the analogy between cells and electrets. It is here assumed that cell-bound electric fields unite, reach the body surface and the surrounding space and form the thoracic electric field that consists from two concentric structures: the thoracic wall and the heart. If ECG leads measure differences in electric potentials between skin electrodes, they give scalar values that define position of the electric field center along each lead. Repolarised heart muscle acts as a stable positive electric source, while depolarized heart muscle produces much weaker negative electric field. During T-P, P-R and S-T segments electric field is stable, only subtle changes are detectable by skin electrodes. Diastolic electric field forms after ventricular depolarization (T-P segments in the ECG recording). Telediastolic electric field forms after the atria have been depolarized (P-Q segments in the ECG recording). Systolic electric field forms after the ventricular depolarization (S-T segments in the ECG recording). The three ECG waves (P, QRS and T) can then be described as unbalanced transitions of the heart electric field from one stable configuration to the next and in that process the electric field center is temporarily displaced. In the initial phase of QRS, the rapidly diminishing septal electric field makes measured potentials dependent only on positive charges of the corresponding parts of the left and the right heart that lie within the lead axes. If more positive charges are near the "DOWN" electrode than near the "UP" electrode, a Q wave will be seen, otherwise an R wave is expected. Repolarization of the ventricular muscle is dampened by the early septal muscle repolarization that reduces deflection of T waves. Since the "UP" electrode of most leads is near the usually larger left ventricle muscle, T waves are in these leads positive, although of smaller amplitude and longer

  13. Design of ECG Monitoring of the Amplified Signal Based on AD620%基于AD620的心电监测放大信号的设计

    Institute of Scientific and Technical Information of China (English)

    常星

    2016-01-01

    为了方便人们实时了解心律变化,得到较为准确的心电信号特征。提出了一种心电放大信号电路的设计,该设计采用低功耗、低成本、高精度仪表放大器AD620将心电信号(ECG)进行数据采集放大后,然后再经过低噪声、高精度、高度运算放大器OP07组成的滤波电路及主放大电路对前级放大的心电信号进行电路处理从而得到较为精确的心电信号。通过硬件测试系统达到了能够检测心电信好的目的。设计具有一定的实际应用价值。%In order to facilitate the people to understand the real-time heart rate variability to obtain more a-ccurate ECG feature.Proposed a ECG signal amplifying circuit design that uses low-power,low cost,high a-ccuracy instrumentation amplifier AD620 the ECG(ECG)be enlarged after data col ection,and then through t-he low pass noise,high accuracy,the height of the operational amplifier OP07 filter circuit composed of the m-ain amplifier and preamp on the ECG signal processing circuit to obtain a more accurate ECG.Hardware test system capable of detecting heart Telecom reached a good purpose.Design has some practical value.

  14. Frequency Band Analysis of Electrocardiogram (ECG) Signals for Human Emotional State Classification Using Discrete Wavelet Transform (DWT).

    Science.gov (United States)

    Murugappan, Murugappan; Murugappan, Subbulakshmi; Zheng, Bong Siao

    2013-07-01

    [Purpose] Intelligent emotion assessment systems have been highly successful in a variety of applications, such as e-learning, psychology, and psycho-physiology. This study aimed to assess five different human emotions (happiness, disgust, fear, sadness, and neutral) using heart rate variability (HRV) signals derived from an electrocardiogram (ECG). [Subjects] Twenty healthy university students (10 males and 10 females) with a mean age of 23 years participated in this experiment. [Methods] All five emotions were induced by audio-visual stimuli (video clips). ECG signals were acquired using 3 electrodes and were preprocessed using a Butterworth 3rd order filter to remove noise and baseline wander. The Pan-Tompkins algorithm was used to derive the HRV signals from ECG. Discrete wavelet transform (DWT) was used to extract statistical features from the HRV signals using four wavelet functions: Daubechies6 (db6), Daubechies7 (db7), Symmlet8 (sym8), and Coiflet5 (coif5). The k-nearest neighbor (KNN) and linear discriminant analysis (LDA) were used to map the statistical features into corresponding emotions. [Results] KNN provided the maximum average emotion classification rate compared to LDA for five emotions (sadness - 50.28%; happiness - 79.03%; fear - 77.78%; disgust - 88.69%; and neutral - 78.34%). [Conclusion] The results of this study indicate that HRV may be a reliable indicator of changes in the emotional state of subjects and provides an approach to the development of a real-time emotion assessment system with a higher reliability than other systems.

  15. Study on ECG(Electrocardiogram)Diagnosis of Patients With Hyperkalemia%高钾血症患者的心电图诊断研究

    Institute of Scientific and Technical Information of China (English)

    张荣丽

    2016-01-01

    目的:研究高钾血症患者心电图诊断方法及价值。方法研究年度2015年1月~2015年11月,纳入高钾血症共45例,给予全部心电图检查,并分析其诊断价值。结果心电图共诊断42例,诊断准确率93.33%,准确率较高。结论高钾血症患者心电图诊断价值高。%Objective ECG diagnosis method and its value in diagnosis of patients with hyperkalemia are to be studied. Methods Chose 45 patients with hyperkalemia who were treated in hospital from January 2015 to November 2015 and diagnose them with ECG and then made an analysis on its diagnosis value. Results There were 42 patients to be diagnosed successfully by ECG and the diagnosis accuracy rate was up to 93.33%,such a result was quite accurate. Conclusion ECG is of great value in diagnosis of patients with hyperkalemia,thus,it is quite worthwhile to be applied widespread.

  16. Enhanced real-time ECG coder for packetized telecardiology applications.

    Science.gov (United States)

    Alesanco, Alvaro; Olmos, Salvador; Istepanian, Robert S H; García, José

    2006-04-01

    A new real-time compression method for electrocardiogram (ECG) signals has been developed based on the wavelet transform approach. The method is specifically adaptable for packetized telecardiology applications. The signal is segmented into beats and a beat template is subtracted from them, producing a residual signal. Beat templates and residual signals are coded with a wavelet expansion. Compression is achieved by selecting a subset of wavelet coefficients. The number of selected coefficients depends on a threshold which has different definitions depending on the operational mode of the coder. Compression performance has been tested using a subset of ECG records from MIT-BIH Arrhythmia database. This method has been designed for real-time packetized telecardiology scenarios both in wired and wireless environments.

  17. QRS complex detection in ECG signal for wearable devices.

    Science.gov (United States)

    Arefin, M Riadh; Tavakolian, Kouhyar; Fazel-Rezai, Reza

    2015-01-01

    This paper presents QRS complex detection algorithm based on dual slope technique, which is suitable for wearable electrocardiogram (ECG) applications. For cardiac patients of different arrhythmias, ECG signals are needed to be monitored over an extensive period of time. Thus, the wearable heart monitoring system needs computationally efficient QRS detection technique with good accuracy. In this paper, a method of QRS detection based on two slopes on both sides of an R peak is presented which is computationally efficient. Based on the slopes, first, a variable measuring steepness is developed, then by introducing an adjustable R-R interval based window and adaptive thresholding techniques, depending on the number of peaks detected in such window, R peaks are detected. The algorithm was evaluated against MIT/BIH arrhythmia database and achieved 99.16% detection rate with sensitivity of 0.9935 and positive predictivity of 0.9981. The method was compared with two widely used R peaks detection algorithms.

  18. Combining Wavelet Transform and Hidden Markov Models for ECG Segmentation

    Directory of Open Access Journals (Sweden)

    Jérôme Boudy

    2007-01-01

    Full Text Available This work aims at providing new insights on the electrocardiogram (ECG segmentation problem using wavelets. The wavelet transform has been originally combined with a hidden Markov models (HMMs framework in order to carry out beat segmentation and classification. A group of five continuous wavelet functions commonly used in ECG analysis has been implemented and compared using the same framework. All experiments were realized on the QT database, which is composed of a representative number of ambulatory recordings of several individuals and is supplied with manual labels made by a physician. Our main contribution relies on the consistent set of experiments performed. Moreover, the results obtained in terms of beat segmentation and premature ventricular beat (PVC detection are comparable to others works reported in the literature, independently of the type of the wavelet. Finally, through an original concept of combining two wavelet functions in the segmentation stage, we achieve our best performances.

  19. Wavelet transform based ECG signal filtering implemented on FPGA

    Directory of Open Access Journals (Sweden)

    Germán-Salló Zoltán

    2011-12-01

    Full Text Available Filtering electrocardiographic (ECG signals is always a challenge because the accuracy of their interpretation depends strongly on filtering results. The Discrete Wavelet Transform (DWT is an efficient, new and useful tool for signal processing applications and it’s adopted in many domains as biomedical signal filtering. This transform came about from different fields, including mathematics, physics and signal processing, it has a growing applicability due to its so-called multiresolution analyzing capabilities. FPGAs are reconfigurable logic devices made up of arrays of logic cells and routing channels having some specific characteristics which allow to use them in signal processing applications. This paper presents a DWT based ECG signal denoising method implemented on FPGA, using Matlab specific Xilinx tool, as System Generator, the procedure is simulated and evaluated through filtering specific parameters.

  20. Heart detection and diagnosis based on ECG and EPCG relationships

    Science.gov (United States)

    Phanphaisarn, W; Roeksabutr, A; Wardkein, P; Koseeyaporn, J; Yupapin, PP

    2011-01-01

    A new design of a system for preliminary detection of defective hearts is proposed which is composed of two subsystems, in which one is based on the relationship between the electrocardiogram (ECG) and phonocardiogram (PCG) signals. The relationship between both signals is determined as an impulse response (h(n)) of a system, where the decision is made based on the linear predictive coding coefficients of a heart’s impulse response. The other subsystem uses a phase space approach, in which the mean squared error between the distance vectors of the phase space of the normal heart and abnormal heart is judged by the likelihood ratio test (Λ) value, on which the decision is made. The advantage of the proposed system is that a heart’s diagnosis system based on the ECG and EPCG signals can lead to high performance heart diagnostics. PMID:22915940

  1. [Changes in ECG examination of patients with trichinosis].

    Science.gov (United States)

    Siwak, E; Droń, D; Pancewicz, S; Zajkowska, J; Snarska, I; Szpakowicz, T; Januszkiewicz, E

    1994-07-01

    In the years 1963-1992, 560 patients with the diagnosis of trichinosis were treated in the Department of Parasitic Diseases and Neuroinfections, including 310 women (55.3%) and 250 men (44.7%) aged from 6 to 75 years. Out of this number of patients in 59 cases (10.5%) myocardial damage was found in the course of the disease. The most frequently found changes in ECG record were ventricular repolarization disturbances (66.1%) which persisted in 18.6% of cases before discharge from the hospital. Depolarization disturbances accounted for 32.2% of cases and persisted before discharge from the hospital in 10.1% of patients. In 6.7% of patients, persistence of pathological ECG record was found during the 4th month after the hospitalization which may be an evidence of prolongation of the inflammatory process within the myocardium.

  2. ECG contamination of EEG signals: effect on entropy.

    Science.gov (United States)

    Chakrabarti, Dhritiman; Bansal, Sonia

    2016-02-01

    Entropy™ is a proprietary algorithm which uses spectral entropy analysis of electroencephalographic (EEG) signals to produce indices which are used as a measure of depth of hypnosis. We describe a report of electrocardiographic (ECG) contamination of EEG signals leading to fluctuating erroneous Entropy values. An explanation is provided for mechanism behind this observation by describing the spread of ECG signals in head and neck and its influence on EEG/Entropy by correlating the observation with the published Entropy algorithm. While the Entropy algorithm has been well conceived, there are still instances in which it can produce erroneous values. Such erroneous values and their cause may be identified by close scrutiny of the EEG waveform if Entropy values seem out of sync with that expected at given anaesthetic levels.

  3. Using ordinal partition transition networks to analyze ECG data

    Science.gov (United States)

    Kulp, Christopher W.; Chobot, Jeremy M.; Freitas, Helena R.; Sprechini, Gene D.

    2016-07-01

    Electrocardiogram (ECG) data from patients with a variety of heart conditions are studied using ordinal pattern partition networks. The ordinal pattern partition networks are formed from the ECG time series by symbolizing the data into ordinal patterns. The ordinal patterns form the nodes of the network and edges are defined through the time ordering of the ordinal patterns in the symbolized time series. A network measure, called the mean degree, is computed from each time series-generated network. In addition, the entropy and number of non-occurring ordinal patterns (NFP) is computed for each series. The distribution of mean degrees, entropies, and NFPs for each heart condition studied is compared. A statistically significant difference between healthy patients and several groups of unhealthy patients with varying heart conditions is found for the distributions of the mean degrees, unlike for any of the distributions of the entropies or NFPs.

  4. Clinical disease presentation and ECG characteristics of LMNA mutation carriers

    Science.gov (United States)

    Ollila, Laura; Nikus, Kjell; Holmström, Miia; Jalanko, Mikko; Jurkko, Raija; Kaartinen, Maija; Koskenvuo, Juha; Kuusisto, Johanna; Kärkkäinen, Satu; Palojoki, Eeva; Reissell, Eeva; Piirilä, Päivi; Heliö, Tiina

    2017-01-01

    Objective Mutations in the LMNA gene encoding lamins A and C of the nuclear lamina are a frequent cause of cardiomyopathy accounting for 5–8% of familial dilated cardiomyopathy (DCM). Our aim was to study disease onset, presentation and progression among LMNA mutation carriers. Methods Clinical follow-up data from 27 LMNA mutation carriers and 78 patients with idiopathic DCM without an LMNA mutation were collected. In addition, ECG data were collected and analysed systematically from 20 healthy controls. Results Kaplan-Meier analysis revealed no difference in event-free survival (death, heart transplant, resuscitation and appropriate implantable cardioverter-defibrillator therapy included as events) between LMNA mutation carriers and DCM controls (p=0.5). LMNA mutation carriers presented with atrial fibrillation at a younger age than the DCM controls (47 vs 57 years, p=0.003). Male LMNA mutation carriers presented with clinical manifestations roughly a decade earlier than females. In close follow-up non-sustained ventricular tachycardia was detected in 78% of LMNA mutation carriers. ECG signs of septal remodelling were present in 81% of the LMNA mutation carriers, 21% of the DCM controls and none of the healthy controls giving a high sensitivity and specificity for the standard ECG in distinguishing LMNA mutation carriers from patients with DCM and healthy controls. Conclusions Male LMNA mutation carriers present clinical manifestations at a younger age than females. ECG septal remodelling appears to distinguish LMNA mutation carriers from healthy controls and patients with DCM without LMNA mutations. PMID:28123761

  5. [Development of a portable dynamic state ECG based on DSP].

    Science.gov (United States)

    Song, Li; Meng, Qing-jian; Zhang, Guang-yu; Cao, Wei-fang

    2009-11-01

    The Portable dynamic state electrocardiogram collecting system is introduced by using TMS302VC5402, TLC320AD50C, liquid crystal display model, and so on. This dissertation describes the work principle of the system and uses the united algorithm based on wavelet to identify and locate the ECG characteristic waves. This system has as follows of advantages: big memory, low noise,high common mode rejection ratio, the low power consume,the long record time etc.

  6. Discussion of "Computational Electrocardiography: Revisiting Holter ECG Monitoring".

    Science.gov (United States)

    Baumgartner, Christian; Caiani, Enrico G; Dickhaus, Hartmut; Kulikowski, Casimir A; Schiecke, Karin; van Bemmel, Jan H; Witte, Herbert

    2016-08-01

    This article is part of a For-Discussion-Section of Methods of Information in Medicine about the paper "Computational Electrocardiography: Revisiting Holter ECG Monitoring" written by Thomas M. Deserno and Nikolaus Marx. It is introduced by an editorial. This article contains the combined commentaries invited to independently comment on the paper of Deserno and Marx. In subsequent issues the discussion can continue through letters to the editor.

  7. A printed, dry electrode Frank configuration vest for ambulatory vectorcardiographic monitoring

    Science.gov (United States)

    Paul, Gordon; Torah, Russel; Beeby, Steve; Tudor, John

    2017-02-01

    This paper describes the design and fabrication of a screen printed network of bio-potential measurement electrodes on a garment, in this case a vest. The electrodes are placed according to the Frank configuration, which allows monitoring of the electrical behavior of the heart in three spatial orientations. The vest is designed to provide stable contact pressure on the electrodes. The electrodes are fabricated from stencil printed carbon loaded rubber and are connected by screen printed silver polymer conductive tracks to an array of vias, which form an electrical connection to the other side of the textile. The vest is tested and compared to Frank configuration recordings that were obtained using standard self-adhesive ECG electrodes. The vest was successfully used to obtain Frank configuration recordings with minimal baseline drift. The vest is fabricated using only technologies found in standard textile production lines and can be used with a reduced setup effort compared to clinical 12-lead examinations.

  8. Performance Comparison of Windowing Techniques for ECG Signal Enhancement

    Directory of Open Access Journals (Sweden)

    K.Sravan Kumar

    2014-12-01

    Full Text Available Electrocardiogram (ECG signal is generally corrupted by various artifacts like baseline wander, power line interference (50/60 Hz and electromyography noise and these must be removed before diagnosis. The task propounded in this article is removal of low frequency interference i.e. baseline wandering and high frequency noise i.e. electromyography in ECG signal and digital filters are implemented to delete it. The digital filters accomplished are FIR with various windowing methods as of Rectangular, Hann, Blackman, Hamming, and Kaiser. The results received are at order of 300,450,600.The signal taken of the MIT-BIH database which contains the normal and abnormal waveforms. The work has been in MATLAB where filters are implemented in FDA Tool. The result received for entire FIR filters with various windows are evaluated the waveforms, power spectrums density, signal to noise ratio (SNR and means square error (MSE of the noisy and filtered ECG signals. The filter which shows the excellent outcomes is the Kaiser Window.

  9. ECG Analysis based on Wavelet Transform and Modulus Maxima

    Directory of Open Access Journals (Sweden)

    Mourad Talbi

    2012-01-01

    Full Text Available In this paper, we have developed a new technique of P, Q, R, S and T Peaks detection using Wavelet Transform (WT and Modulus maxima. One of the commonest problems in electrocardiogram (ECG signal processing, is baseline wander removal suppression. Therefore we have removed the baseline wander in order to make easier the detection of the peaks P and T. Those peaks are detected after the QRS detection. The proposed method is based on the application of the discritized continuous wavelet transform (Mycwt used for the Bionic wavelet transform, to the ECG signal in order to detect R-peaks in the first stage and in the second stage, the Q and S peaks are detected using the R-peaks localization. Finally the Modulus maxima are used in the undecimated wavelet transform (UDWT domain in order to detect the others peaks (P, T. This detection is performed by using a varying-length window that is moving along the whole signal. For evaluating the proposed method, we have compared it to others techniques based on wavelets. In this evaluation, we have used many ECG signals taken from MIT-BIH database. The obtained results show that the proposed method outperforms a number of conventional techniques used for our evaluation.

  10. Integration of multivariate empirical mode decomposition and independent component analysis for fetal ECG separation from abdominal signals.

    Science.gov (United States)

    Thanaraj, Palani; Roshini, Mable; Balasubramanian, Parvathavarthini

    2016-11-14

    The fetal electrocardiogram (FECG) signals are essential to monitor the health condition of the baby. Fetal heart rate (FHR) is commonly used for diagnosing certain abnormalities in the formation of the heart. Usually, non-invasive abdominal electrocardiogram (AbECG) signals are obtained by placing surface electrodes in the abdomen region of the pregnant woman. AbECG signals are often not suitable for the direct analysis of fetal heart activity. Moreover, the strength and magnitude of the FECG signals are low compared to the maternal electrocardiogram (MECG) signals. The MECG signals are often superimposed with the FECG signals that make the monitoring of FECG signals a difficult task. Primary goal of the paper is to separate the fetal electrocardiogram (FECG) signals from the unwanted maternal electrocardiogram (MECG) signals. A multivariate signal processing procedure is proposed here that combines the Multivariate Empirical Mode Decomposition (MEMD) and Independent Component Analysis (ICA). The proposed method is evaluated with clinical abdominal signals taken from three pregnant women (N= 3) recorded during the 38-41 weeks of the gestation period. The number of fetal R-wave detected (NEFQRS), the number of unwanted maternal peaks (NMQRS), the number of undetected fetal R-wave (NUFQRS) and the FHR detection accuracy quantifies the performance of our method. Clinical investigation with three test subjects shows an overall detection accuracy of 92.8%. Comparative analysis with benchmark signal processing method such as ICA suggests the noteworthy performance of our method.

  11. Accuracy Assessment for Multi-Channel ECG Waveforms Using Soft Computing Methodologies

    Directory of Open Access Journals (Sweden)

    Menta Srinivasulu

    2014-07-01

    Full Text Available ECG waveform rhythmic analysis is very important. In recent trends, analysis processes of ECG waveform applications are available in smart devices. Still, existing methods are not able to accomplish the complete accuracy assessment while classify the multi-channel ECG waveforms. In this paper, proposed analysis of accuracy assessment of the classification of multi-channel ECG waveforms using most popular Soft Computing algorithms. In this research, main focus is on the better rule generation to analyze the multi-channel ECG waveforms. Analysis is mainly done inSoft Computing methods like the Decision Trees with different pruning analysis, Logistic Model Trees with different regression process and Support Vector Machine with Particle Swarm Optimization (SVM-PSO. All these analysis methods are trained and tested with MIT-BIH 12 channel ECG waveforms. Before trained these methods, MSO-FIR filter should be used as data preprocessing for removal of noise from original multi-channel ECG waveforms. MSO technique is used for automatically finding out the cutoff frequency of multichannel ECG waveforms which is used in low-pass filtering process. The classification performance is discussed using mean squared error, member function, classification accuracy, complexity of design, and area under curve on MIT-BIH data. Additionally, this research work is extended for the samples of multi-channel ECG waveforms from the Scope diagnostic center, Hyderabad. Our study assets the best process using the Soft Computing methods for analysis of multi-channel ECG waveforms.

  12. Extended Kalman smoother with differential evolution technique for denoising of ECG signal.

    Science.gov (United States)

    Panigrahy, D; Sahu, P K

    2016-09-01

    Electrocardiogram (ECG) signal gives a lot of information on the physiology of heart. In reality, noise from various sources interfere with the ECG signal. To get the correct information on physiology of the heart, noise cancellation of the ECG signal is required. In this paper, the effectiveness of extended Kalman smoother (EKS) with the differential evolution (DE) technique for noise cancellation of the ECG signal is investigated. DE is used as an automatic parameter selection method for the selection of ten optimized components of the ECG signal, and those are used to create the ECG signal according to the real ECG signal. These parameters are used by the EKS for the development of the state equation and also for initialization of the parameters of EKS. EKS framework is used for denoising the ECG signal from the single channel. The effectiveness of proposed noise cancellation technique has been evaluated by adding white, colored Gaussian noise and real muscle artifact noise at different SNR to some visually clean ECG signals from the MIT-BIH arrhythmia database. The proposed noise cancellation technique of ECG signal shows better signal to noise ratio (SNR) improvement, lesser mean square error (MSE) and percent of distortion (PRD) compared to other well-known methods.

  13. Ischemia episode detection in ECG using kernel density estimation, support vector machine and feature selection

    Directory of Open Access Journals (Sweden)

    Park Jinho

    2012-06-01

    Full Text Available Abstract Background Myocardial ischemia can be developed into more serious diseases. Early Detection of the ischemic syndrome in electrocardiogram (ECG more accurately and automatically can prevent it from developing into a catastrophic disease. To this end, we propose a new method, which employs wavelets and simple feature selection. Methods For training and testing, the European ST-T database is used, which is comprised of 367 ischemic ST episodes in 90 records. We first remove baseline wandering, and detect time positions of QRS complexes by a method based on the discrete wavelet transform. Next, for each heart beat, we extract three features which can be used for differentiating ST episodes from normal: 1 the area between QRS offset and T-peak points, 2 the normalized and signed sum from QRS offset to effective zero voltage point, and 3 the slope from QRS onset to offset point. We average the feature values for successive five beats to reduce effects of outliers. Finally we apply classifiers to those features. Results We evaluated the algorithm by kernel density estimation (KDE and support vector machine (SVM methods. Sensitivity and specificity for KDE were 0.939 and 0.912, respectively. The KDE classifier detects 349 ischemic ST episodes out of total 367 ST episodes. Sensitivity and specificity of SVM were 0.941 and 0.923, respectively. The SVM classifier detects 355 ischemic ST episodes. Conclusions We proposed a new method for detecting ischemia in ECG. It contains signal processing techniques of removing baseline wandering and detecting time positions of QRS complexes by discrete wavelet transform, and feature extraction from morphology of ECG waveforms explicitly. It was shown that the number of selected features were sufficient to discriminate ischemic ST episodes from the normal ones. We also showed how the proposed KDE classifier can automatically select kernel bandwidths, meaning that the algorithm does not require any numerical

  14. Speaking Fluently And Accurately

    Institute of Scientific and Technical Information of China (English)

    JosephDeVeto

    2004-01-01

    Even after many years of study,students make frequent mistakes in English. In addition, many students still need a long time to think of what they want to say. For some reason, in spite of all the studying, students are still not quite fluent.When I teach, I use one technique that helps students not only speak more accurately, but also more fluently. That technique is dictations.

  15. A microcontroller-based telemetry system for sympathetic nerve activity and ECG measurement.

    Science.gov (United States)

    Harada, E; Yonezawa, Y; Caldwell, W M; Hahn, A W

    1999-01-01

    A telemetry system employing a low power 8-bit microcontroller has been developed for chronic unanesthetized small animal studies. The two-channel system is designed for use with animals in shielded cages. Analog signals from implantable ECG and nerve electrodes are converted to an 8-bit serial digital format. This is accomplished by individual 8 bit A/D converters included in the microcontroller, which also has serial I/O port. The converted serial binary code is applied directly to an antenna wire. Therefore, the system does not need to employ a separate transmitter, such as in FM or infrared optical telemeters. The system is used in a shielded animal cage to reduce interference from external radio signals and 60 Hz power line fields. The code is received by a high input impedance amplifier in the cage and is then demodulated. The telemeter is powered by a small 3 V lithium battery, which provides 100 hours of continuous operation. The circuit is constructed on two 25 x 25 mm. printed circuit boards and encapsulated in epoxy, yielding a total volume of 6.25 cc. The weight is 15 g.

  16. Complete electrode model in EEG: relationship and differences to the point electrode model

    Science.gov (United States)

    Pursiainen, S.; Lucka, F.; Wolters, C. H.

    2012-02-01

    In electroencephalography (EEG) source analysis, a primary current density generated by the neural activity of the brain is reconstructed from external electrode voltage measurements. This paper focuses on accurate and effective simulations of EEG through the complete electrode model (CEM). The CEM allows for the incorporation of the electrode size, shape and effective contact impedance into the forward simulation. Both neural currents in the brain and shunting currents between the electrodes and the skin can affect the measured voltages in the CEM. The goal of this study was to investigate the CEM by comparing it with the point electrode model (PEM), which is the current standard electrode model for EEG. We used a three-dimensional, realistic and high-resolution finite element head model as the reference computational domain in the comparison. The PEM could be formulated as a limit of the CEM, in which the effective impedance of each electrode goes to infinity and the size tends to zero. Numerical results concerning the forward and inverse errors and electrode voltage strengths with different impedances and electrode sizes are presented. Based on the results obtained, limits for extremely high and low impedance values of the shunting currents are suggested.

  17. CLASSIFICATION OF ECG DATA FOR PREDICTIVE ANALYSIS TO ASSIST IN MEDICAL DECISIONS

    Directory of Open Access Journals (Sweden)

    Mrs. A. R. Chitupe

    2013-11-01

    Full Text Available In recent years due to physical and mental stress in the working environments the cases of medicaldiagnosis using ECG are increasing up-bounds. The critical decisions in diagnosis referring to the normal ECG or indicative dysfunctions of the heart results into overlapped data values causing ambiguities. This research paper performs analytical processing and related mining to classify normal and abnormalities of the ECG. The ECG is agraphical representation generated due to polarities of the weak electrical signals generated in certain defined timely manner. With reference to time an ECG is used to measure the rate and regularity of heartbeats, as well as some special behaviour of the patient. ECG can be used to investigate heart abnormalities.

  18. Reducing of gradient induced artifacts on the ECG signal during MRI examinations using Wilcoxon filter

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2016-09-01

    Full Text Available The electrocardiogramm (ECG is the state-of-the-art signal for gating in cardiovascular magnetic resonance imaging and patient monitoring. Using the ECG for gating and monitoring during the magnetic resonance imaging examination is a high challenging task due to the superimposition of the magnetohydrodynamic effect, radio-frequency (RF pulses and fast switching gradient magnetic fields. The gradient induced artifacts hamper the correct QRS detection which is needed for correct gating and heart rate calculation and ECG displaying for patient monitoring. To suppress the gradient artifacts from the ECG signal acquired during MRI, a technique based on the Wilcoxon filter was developed. It was evaluated using ECG signals of 14 different subjects acquired in a 3 T MRI scanner. It could be shown reliable results for reducing gradient induced artifacts in the ECG signal in real-time.

  19. [Design of the Mobile ECG Monitoring System Based on Android 4.3].

    Science.gov (United States)

    Zhang, Shun; Lian, Yuxi; Qin, Yajie; Wang, Yuanyuan

    2015-07-01

    To monitor and record Electrocardiograph (ECG) signals for 24 hours, a mobile ECG monitoring system is designed based on Android 4.3. In this system, domestic indigenous E9622A is used to acquire ECG signals and TI CC2541 is adopted to communicate with mobile phones. The program is implemented on the Android platform to display and process ECG signals. The whole system is integrated on a 2 cm x 2 cm PCB. From experiments, it is shown that ECG signals can be obtained effectively when this system is worn, and clear ECG waveforms and parameters can be shown on the phones. With this system, arrhythmia can be diagnosed preliminarily. It is also shown that the system is low-power, low-cost, flexible and portable.

  20. A Comparison of IIR and Wavelet Filtering for Noise Reduction of the ECG.

    Science.gov (United States)

    Sørensen, Js; Johannesen, L; Grove, Usl; Lundhus, K; Couderc, J-P; Graff, C

    2010-09-26

    This study compares the ability to preserve information and reduce noise contaminants on the ECG for five wavelet filters and three IIR filters. Two 3-lead Holter ECGs were used. White Gaussian Noise was added to the first ECG in increments of 10% coverage. The second ECG contained alternating muscle transients and noise-free segments. Computation times and SNR improvements for different noise coverages were calculated and compared. RMS errors were calculated from noise-free segments on the ECG with transient muscle noise. Wavelet filters improved SNR more than IIR filters when the signal coverage was more than 50% noise. In contrast, the computation times were shorter for IIR filters (6 s) than for wavelet filters (88 s). On the ECG with transient muscle noise there was a trade-off in performance between wavelet and IIR filtering. In a clinical setting where the amount of noise is unknown, using IIR filters appears to be preferred for consistent performance.

  1. Riemann Liouvelle Fractional Integral based Empirical Mode Decomposition for ECG Denoising.

    Science.gov (United States)

    Jain, Shweta; Bajaj, Varun; Kumar, Anil

    2017-09-18

    Electrocardiograph (ECG) denoising is the most important step in diagnosis of heart related diseases, as the diagnosis gets influenced with noises. In this paper, a new method for ECG denoising is proposed, which incorporates empirical mode decomposition algorithm and Riemann Liouvelle (RL) fractional integral filtering. In the proposed method, noisy ECG signal is decomposed into its intrinsic mode functions (IMFs); from which noisy IMFs are identified by proposed noisy-IMFs identification methodology. RL fractional integral filtering is applied on noisy IMFs to get denoised IMFs; ECG signal is reconstructed with denoised IMFs and remaining signal dominant IMFs to obtain noise-free ECG signal. Proposed methodology is tested with MIT-BIH arrhythmia database. Its performance, in terms of signal to noise ratio (SNR) and mean square error (MSE), is compared with other related fractional integral and EMD based ECG denoising methods. The obtained results by proposed method prove that the proposed method gives efficient noise removal performance.

  2. FUEL CELL ELECTRODE MATERIALS

    Science.gov (United States)

    FUEL CELL ELECTRODE MATERIALS. RAW MATERIAL SELECTION INFLUENCES POLARIZATION BUT IS NOT A SINGLE CONTROLLING FACTOR. AVAILABLE...DATA INDICATES THAT AN INTERRELATIONSHIP OF POROSITY, AVERAGE PORE VOLUME, AND PERMEABILITY CONTRIBUTES TO ELECTRODE FUEL CELL BEHAVIOR.

  3. Optimization of return electrodes in neurostimulating arrays

    Science.gov (United States)

    Flores, Thomas; Goetz, Georges; Lei, Xin; Palanker, Daniel

    2016-06-01

    Objective. High resolution visual prostheses require dense stimulating arrays with localized inputs of individual electrodes. We study the electric field produced by multielectrode arrays in electrolyte to determine an optimal configuration of return electrodes and activation sequence. Approach. To determine the boundary conditions for computation of the electric field in electrolyte, we assessed current dynamics using an equivalent circuit of a multielectrode array with interleaved return electrodes. The electric field modeled with two different boundary conditions derived from the equivalent circuit was then compared to measurements of electric potential in electrolyte. To assess the effect of return electrode configuration on retinal stimulation, we transformed the computed electric fields into retinal response using a model of neural network-mediated stimulation. Main results. Electric currents at the capacitive electrode-electrolyte interface redistribute over time, so that boundary conditions transition from equipotential surfaces at the beginning of the pulse to uniform current density in steady state. Experimental measurements confirmed that, in steady state, the boundary condition corresponds to a uniform current density on electrode surfaces. Arrays with local return electrodes exhibit improved field confinement and can elicit stronger network-mediated retinal response compared to those with a common remote return. Connecting local return electrodes enhances the field penetration depth and allows reducing the return electrode area. Sequential activation of the pixels in large monopolar arrays reduces electrical cross-talk and improves the contrast in pattern stimulation. Significance. Accurate modeling of multielectrode arrays helps optimize the electrode configuration to maximize the spatial resolution, contrast and dynamic range of retinal prostheses.

  4. A dynamic Fourier series for the compression of ECG using FFT and adaptive coefficient estimation.

    Science.gov (United States)

    al-Nashash, H A

    1995-04-01

    In this article, a new ECG data compression technique is proposed. The method relies on modelling quasi-periodic ECG signals as a dynamic Fourier series. Fourier coefficients are continuously estimated using either an FFT algorithm or the adaptive least mean square algorithm. Results from simulated normal and pathological ECGs are presented and discussed. The merits of each of the above two methods are also illustrated. Furthermore, a comparison with other compression techniques is also discussed.

  5. On the improved correlative prediction scheme for aliased electrocardiogram (ECG) data compression.

    Science.gov (United States)

    Gao, Xin

    2012-01-01

    An improved scheme for aliased electrocardiogram (ECG) data compression has been constructed, where the predictor exploits the correlative characteristics of adjacent QRS waveforms. The twin-R correlation prediction and lifting wavelet transform (LWT) for periodical ECG waves exhibits feasibility and high efficiency to achieve lower distortion rates with realizable compression ratio (CR); grey predictions via GM(1, 1) model have been adopted to evaluate the parametric performance for ECG data compression. Simulation results illuminate the validity of our approach.

  6. Microresonator electrode design

    Science.gov (United States)

    Olsson, III, Roy H.; Wojciechowski, Kenneth; Branch, Darren W.

    2016-05-10

    A microresonator with an input electrode and an output electrode patterned thereon is described. The input electrode includes a series of stubs that are configured to isolate acoustic waves, such that the waves are not reflected into the microresonator. Such design results in reduction of spurious modes corresponding to the microresonator.

  7. A Simple Hydrogen Electrode

    Science.gov (United States)

    Eggen, Per-Odd

    2009-01-01

    This article describes the construction of an inexpensive, robust, and simple hydrogen electrode, as well as the use of this electrode to measure "standard" potentials. In the experiment described here the students can measure the reduction potentials of metal-metal ion pairs directly, without using a secondary reference electrode. Measurements…

  8. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  9. A Simple Hydrogen Electrode

    Science.gov (United States)

    Eggen, Per-Odd

    2009-01-01

    This article describes the construction of an inexpensive, robust, and simple hydrogen electrode, as well as the use of this electrode to measure "standard" potentials. In the experiment described here the students can measure the reduction potentials of metal-metal ion pairs directly, without using a secondary reference electrode. Measurements…

  10. Analysis of ECG-trunk muscle signal amplitude and heart rate relationship.

    Science.gov (United States)

    Benosman, Mourad-M; Bereksi-Reguig, Fethi; Salerud, E Göran

    2013-10-01

    The objective of this paper is to investigate if bioelectrical signals, generated from trunk muscles identified in an electrocardiogram (ECG) signal presented in this paper as ECG-Trunk Muscles Signals amplitude (Ecg-TMSA) are correlated with Heart rate (HR) during different levels of physical activity and also if Ecg-TMSA is not influenced by mental activity. HR and Ecg-TMSA were derived from ECG in 14 subjects when walking and jogging at different treadmill velocities from 4-10 (km h(-1)). The mean relationship for all 14 subjects was HR = (42.3 ± 0.2) + (45.3 ± 2.8) Ecg-TMSA, r(2 )= 0.91. The result of one individual data points example for a 21 min experiment was (r(2 )= 0.93, p Ecg-TMSA and HR. Moreover, the Ecg-TMSA was not affected by mental activity.

  11. A novel approach to ECG classification based upon two-layered HMMs in body sensor networks.

    Science.gov (United States)

    Liang, Wei; Zhang, Yinlong; Tan, Jindong; Li, Yang

    2014-03-27

    This paper presents a novel approach to ECG signal filtering and classification. Unlike the traditional techniques which aim at collecting and processing the ECG signals with the patient being still, lying in bed in hospitals, our proposed algorithm is intentionally designed for monitoring and classifying the patient's ECG signals in the free-living environment. The patients are equipped with wearable ambulatory devices the whole day, which facilitates the real-time heart attack detection. In ECG preprocessing, an integral-coefficient-band-stop (ICBS) filter is applied, which omits time-consuming floating-point computations. In addition, two-layered Hidden Markov Models (HMMs) are applied to achieve ECG feature extraction and classification. The periodic ECG waveforms are segmented into ISO intervals, P subwave, QRS complex and T subwave respectively in the first HMM layer where expert-annotation assisted Baum-Welch algorithm is utilized in HMM modeling. Then the corresponding interval features are selected and applied to categorize the ECG into normal type or abnormal type (PVC, APC) in the second HMM layer. For verifying the effectiveness of our algorithm on abnormal signal detection, we have developed an ECG body sensor network (BSN) platform, whereby real-time ECG signals are collected, transmitted, displayed and the corresponding classification outcomes are deduced and shown on the BSN screen.

  12. Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes.

    Science.gov (United States)

    Fensli, Rune; Gundersen, Torstein; Snaprud, Tormod; Hejlesen, Ole

    2013-06-01

    In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specialists with regard to signal quality for performing arrhythmia diagnosis. In addition, calculated R-R intervals from the two systems were correlated. A total number of 16 patients participated in the study. It can be considered that recorded ECG signals obtained from the wireless ECG system had an acceptable quality for arrhythmia diagnosis. Some of the patients used the wireless sensor while doing physical sport activities, and the quality of the recorded ECG signals made it possible to perform arrhythmia diagnostics even under such conditions. Consequently, this makes possible improvements in correlating arrhythmias to physical activities.

  13. A Low Power Linear Phase Digital FIR Filter for Wearable ECG Devices.

    Science.gov (United States)

    Lian, Yong; Yu, Jianghong

    2005-01-01

    In this paper we present a low power linear phase digital FIR filter which is a part of an ECG-on-Chip. The ECG-on-Chip can be embedded into clothing to acquire the electrocardiogram (ECG) signal and send a warning message to a mobile phone or PDA if an abnormal ECG is detected. The proposed new filter structure significantly reduces the arithmetic operations for each sample which in turn lowers the power consumption. The filter is developed based on the interpolated finite impulse filter technique and is very attractive for a low cost and low power VLSI implementation.

  14. The Telemetric and Holter ECG Warehouse (THEW): the first three years of development and research.

    Science.gov (United States)

    Couderc, Jean-Philippe

    2012-01-01

    The Telemetric and Holter ECG Warehouse (THEW) hosts more than 3700 digital 24-Holter ECG recordings from 13 independent studies. In addition to the ECGs, the repository includes patient information in separate clinical database with content varying according to the study focus. In its third year of activities, the THEW database has been accessed by researchers from 37 universities and 16 corporations located in 16 countries worldwide. Twenty publications were released primarily focusing on the development and validation of ECG-based technologies. This communication describes the content of the databases of the repository with brief summary of the research and development projects completed using these data.

  15. A Novel Approach to ECG Classification Based upon Two-Layered HMMs in Body Sensor Networks

    Directory of Open Access Journals (Sweden)

    Wei Liang

    2014-03-01

    Full Text Available This paper presents a novel approach to ECG signal filtering and classification. Unlike the traditional techniques which aim at collecting and processing the ECG signals with the patient being still, lying in bed in hospitals, our proposed algorithm is intentionally designed for monitoring and classifying the patient’s ECG signals in the free-living environment. The patients are equipped with wearable ambulatory devices the whole day, which facilitates the real-time heart attack detection. In ECG preprocessing, an integral-coefficient-band-stop (ICBS filter is applied, which omits time-consuming floating-point computations. In addition, two-layered Hidden Markov Models (HMMs are applied to achieve ECG feature extraction and classification. The periodic ECG waveforms are segmented into ISO intervals, P subwave, QRS complex and T subwave respectively in the first HMM layer where expert-annotation assisted Baum-Welch algorithm is utilized in HMM modeling. Then the corresponding interval features are selected and applied to categorize the ECG into normal type or abnormal type (PVC, APC in the second HMM layer. For verifying the effectiveness of our algorithm on abnormal signal detection, we have developed an ECG body sensor network (BSN platform, whereby real-time ECG signals are collected, transmitted, displayed and the corresponding classification outcomes are deduced and shown on the BSN screen.

  16. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    Directory of Open Access Journals (Sweden)

    Hongqiang Li

    2016-10-01

    Full Text Available Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  17. ECG De-noising: A comparison between EEMD-BLMS and DWT-NN algorithms.

    Science.gov (United States)

    Kærgaard, Kevin; Jensen, Søren Hjøllund; Puthusserypady, Sadasivan

    2015-08-01

    Electrocardiogram (ECG) is a widely used non-invasive method to study the rhythmic activity of the heart and thereby to detect the abnormalities. However, these signals are often obscured by artifacts from various sources and minimization of these artifacts are of paramount important. This paper proposes two adaptive techniques, namely the EEMD-BLMS (Ensemble Empirical Mode Decomposition in conjunction with the Block Least Mean Square algorithm) and DWT-NN (Discrete Wavelet Transform followed by Neural Network) methods in minimizing the artifacts from recorded ECG signals, and compares their performance. These methods were first compared on two types of simulated noise corrupted ECG signals: Type-I (desired ECG+noise frequencies outside the ECG frequency band) and Type-II (ECG+noise frequencies both inside and outside the ECG frequency band). Subsequently, they were tested on real ECG recordings. Results clearly show that both the methods works equally well when used on Type-I signals. However, on Type-II signals the DWT-NN performed better. In the case of real ECG data, though both methods performed similar, the DWT-NN method was a slightly better in terms of minimizing the high frequency artifacts.

  18. Can Functional Cardiac Age be Predicted from ECG in a Normal Healthy Population

    Science.gov (United States)

    Schlegel, Todd; Starc, Vito; Leban, Manja; Sinigoj, Petra; Vrhovec, Milos

    2011-01-01

    In a normal healthy population, we desired to determine the most age-dependent conventional and advanced ECG parameters. We hypothesized that changes in several ECG parameters might correlate with age and together reliably characterize the functional age of the heart. Methods: An initial study population of 313 apparently healthy subjects was ultimately reduced to 148 subjects (74 men, 84 women, in the range from 10 to 75 years of age) after exclusion criteria. In all subjects, ECG recordings (resting 5-minute 12-lead high frequency ECG) were evaluated via custom software programs to calculate up to 85 different conventional and advanced ECG parameters including beat-to-beat QT and RR variability, waveform complexity, and signal-averaged, high-frequency and spatial/spatiotemporal ECG parameters. The prediction of functional age was evaluated by multiple linear regression analysis using the best 5 univariate predictors. Results: Ignoring what were ultimately small differences between males and females, the functional age was found to be predicted (R2= 0.69, P ECGs, functional cardiac age can be estimated by multiple linear regression analysis of mostly advanced ECG results. Because some parameters in the regression formula, such as QTcorr, high frequency QRS amplitude and P-wave width also change with disease in the same direction as with increased age, increased functional age of the heart may reflect subtle age-related pathologies in cardiac electrical function that are usually hidden on conventional ECG.

  19. Application of ECG detection technology in experimental teaching%心电检测技术在实验教学中的应用

    Institute of Scientific and Technical Information of China (English)

    葛亚明; 吕淑平

    2014-01-01

    Based on the signal amplification and signal filtering in the undergraduate course of Detection and Conversion Technology ,an ECG signal detection ,amplification and processing circuit is designed .The weak signals on the ECG electrode are firstly magnified by an amplifier ,and a four-order low-pass filter and 50 Hz notch filter are designed ,according to ECG characteristics and types of interference ,and the optical isolator and amplifier circuit are used to guarantee the ECG signal and to get a clear picture of cardiac waveform , valued about 5V .The circuit consists of basic components such as resistors ,capacitors ,photocoupler and can be completed in universal plate easily .Therefore ,it’s not only to improve students’ practical ability ,but also to strengthen the students’ understanding of the theoretical teaching contents .%结合检测与转换技术课程中信号放大和信号滤波两大教学核心内容,以心电信号为对象,设计了符合实验教学的心电信号检测、放大与调理电路,设计四阶低通滤波器和工频50 Hz陷波器滤除干扰,采用光电隔离器对人体进行保护,再利用后置放大电路对心电信号进行二次放大,获得幅值在±5 V左右的清晰的心电波形。电路可在万用板上焊接完成,因此不仅提高了学生的动手能力,更有利于加强学生对理论教学内容的理解。

  20. Mouse ECG findings in aging, with conduction system affecting drugs and in cardiac pathologies: Development and validation of ECG analysis algorithm in mice.

    Science.gov (United States)

    Merentie, Mari; Lipponen, Jukka A; Hedman, Marja; Hedman, Antti; Hartikainen, Juha; Huusko, Jenni; Lottonen-Raikaslehto, Line; Parviainen, Viktor; Laidinen, Svetlana; Karjalainen, Pasi A; Ylä-Herttuala, Seppo

    2015-12-01

    Mouse models are extremely important in studying cardiac pathologies and related electrophysiology, but very few mouse ECG analysis programs are readily available. Therefore, a mouse ECG analysis algorithm was developed and validated. Surface ECG (lead II) was acquired during transthoracic echocardiography from C57Bl/6J mice under isoflurane anesthesia. The effect of aging was studied in young (2-3 months), middle-aged (14 months) and old (20-24 months) mice. The ECG changes associated with pharmacological interventions and common cardiac pathologies, that is, acute myocardial infarction (AMI) and progressive left ventricular hypertrophy (LVH), were studied. The ECG raw data were analyzed with an in-house ECG analysis program, modified specially for mouse ECG. Aging led to increases in P-wave duration, atrioventricular conduction time (PQ interval), and intraventricular conduction time (QRS complex width), while the R-wave amplitude decreased. In addition, the prevalence of arrhythmias increased during aging. Anticholinergic atropine shortened PQ time, and beta blocker metoprolol and calcium-channel blocker verapamil increased PQ interval and decreased heart rate. The ECG changes after AMI included early JT elevation, development of Q waves, decreased R-wave amplitude, and later changes in JT/T segment. In progressive LVH model, QRS complex width was increased at 2 and especially 4 weeks timepoint, and also repolarization abnormalities were seen. Aging, drugs, AMI, and LVH led to similar ECG changes in mice as seen in humans, which could be reliably detected with this new algorithm. The developed method will be very useful for studies on cardiovascular diseases in mice.

  1. The human ECG nonlinear deterministic versus stochastic aspects

    CERN Document Server

    Kantz, H; Kantz, Holger; Schreiber, Thomas

    1998-01-01

    We discuss aspects of randomness and of determinism in electrocardiographic signals. In particular, we take a critical look at attempts to apply methods of nonlinear time series analysis derived from the theory of deterministic dynamical systems. We will argue that deterministic chaos is not a likely explanation for the short time variablity of the inter-beat interval times, except for certain pathologies. Conversely, densely sampled full ECG recordings possess properties typical of deterministic signals. In the latter case, methods of deterministic nonlinear time series analysis can yield new insights.

  2. Developing Barbed Microtip-Based Electrode Arrays for Biopotential Measurement

    Directory of Open Access Journals (Sweden)

    Li-Sheng Hsu

    2014-07-01

    Full Text Available This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back side, a through-silicon via was created during the wet etching process. The experimental results show that the forces required to detach the barbed microtip arrays from human skin, a polydimethylsiloxane (PDMS polymer, and a polyvinylchloride (PVC film were larger compared with those required to detach microtip arrays that lacked barbs. The impedances of the skin-electrode interface were measured and the performance levels of the proposed dry electrode were characterized. Electrode prototypes that employed the proposed tip arrays were implemented. Electroencephalogram (EEG and electrocardiography (ECG recordings using these electrode prototypes were also demonstrated.

  3. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Rui, E-mail: rui_wang1979@yahoo.cn [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Qin, E-mail: tel1367@gmail.com [Department of Emergency, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); He Yi, E-mail: heyi139@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lu Dongxu, E-mail: larry.hi@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2011-11-15

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 {+-} 9.57 HU vs. 72.63 {+-} 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 {+-} 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  4. Comparison of Digital 12-Lead ECG and Digital 12-Lead Holter ECG Recordings in Healthy Male Subjects: Results from a Randomized, Double-Blinded, Placebo-Controlled Clinical Trial.

    Science.gov (United States)

    Wang, Duolao; Bakhai, Ameet; Arezina, Radivoj; Täubel, Jörg

    2016-11-01

    Electrocardiogram (ECG) variability is greatly affected by the ECG recording method. This study aims to compare Holter and standard ECG recording methods in terms of central locations and variations of ECG data. We used the ECG data from a double-blinded, placebo-controlled, randomized clinical trial and used a mixed model approach to assess the agreement between two methods in central locations and variations of eight ECG parameters (Heart Rate, PR, QRS, QT, RR, QTcB, QTcF, and QTcI intervals). A total of 34 heathy male subjects with mean age of 25.7 ± 4.78 years were randomized to receive either active drug or placebo. Digital 12-lead ECG and digital 12-lead Holter ECG recordings were performed to assess ECG variability. There are no significant differences in least square mean between the Holter and the standard method for all ECG parameters. The total variance is consistently higher for the Holter method than the standard method for all ECG parameters except for QRS. The intraclass correlation coefficient (ICC) values for the Holter method are consistently lower than those for the standard method for all ECG parameters except for QRS, in particular, the ICC for QTcF is reduced from 0.86 for the standard method to 0.67 for the Holter method. This study suggests that Holter ECGs recorded in a controlled environment are not significantly different but more variable than those from the standard method. © 2016 Wiley Periodicals, Inc.

  5. Advanced ECG in 2016: is there more than just a tracing?

    Science.gov (United States)

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies

  6. Long-range order of organized oligonucleotide monolayers on Au(111) electrodes

    DEFF Research Database (Denmark)

    Wackerbarth, Hainer; Grubb, Mikala; Zhang, Jingdong;

    2004-01-01

    , with electrochemical potential control of both the sample electrode and the tip. All the data are based on single-crystal, atomically planar Au(111)-electrode surfaces. The high sensitivity of such surfaces provides accurate HS-10A and HS-10AT electrode coverages on the basis of the reductive desorption of the Au...

  7. High Resolution of the ECG Signal by Polynomial Approximation

    Directory of Open Access Journals (Sweden)

    G. Rozinaj

    2006-04-01

    Full Text Available Averaging techniques as temporal averaging and space averaging have been successfully used in many applications for attenuating interference [6], [7], [8], [9], [10]. In this paper we introduce interference removing of the ECG signal by polynomial approximation, with smoothing discrete dependencies, to make up for averaging methods. The method is suitable for low-level signals of the electrical activity of the heart often less than 10 m V. Most low-level signals arising from PR, ST and TP segments which can be detected eventually and their physiologic meaning can be appreciated. Of special importance for the diagnostic of the electrical activity of the heart is the activity bundle of His between P and R waveforms. We have established an artificial sine wave to ECG signal between P and R wave. The aim focus is to verify the smoothing method by polynomial approximation if the SNR (signal-to-noise ratio is negative (i.e. a signal is lower than noise.

  8. Lossless Compression Schemes for ECG Signals Using Neural Network Predictors

    Directory of Open Access Journals (Sweden)

    C. Eswaran

    2007-01-01

    Full Text Available This paper presents lossless compression schemes for ECG signals based on neural network predictors and entropy encoders. Decorrelation is achieved by nonlinear prediction in the first stage and encoding of the residues is done by using lossless entropy encoders in the second stage. Different types of lossless encoders, such as Huffman, arithmetic, and runlength encoders, are used. The performances of the proposed neural network predictor-based compression schemes are evaluated using standard distortion and compression efficiency measures. Selected records from MIT-BIH arrhythmia database are used for performance evaluation. The proposed compression schemes are compared with linear predictor-based compression schemes and it is shown that about 11% improvement in compression efficiency can be achieved for neural network predictor-based schemes with the same quality and similar setup. They are also compared with other known ECG compression methods and the experimental results show that superior performances in terms of the distortion parameters of the reconstructed signals can be achieved with the proposed schemes.

  9. The development of wireless sensor network for ECG monitoring.

    Science.gov (United States)

    Lin, Jun-Liang; Liu, Hsien-Chieh; Tai, Yu-Ting; Wu, Hsin-Hsien; Hsu, Shuo-Jen; Jaw, Fu-Shan; Chen, You-Yin

    2006-01-01

    The main problem we want to solve contains two subjects: The first one is the patient's pressure due to wired physiological signal estimation. With wireless sensor network technique, patients only need to carry a few small nodes, and then the physiological signal can be transmitted in the air. The other subject of the vital problem is that some protocols, like Bluetooth, provide a peer to peer wireless communication technique, but such peer to peer network may need a complex algorithm to find the best data transmission path. In this study, we use the hierarchy routing as network topology that three-layer architecture contains PAN coordinator, router and device. The study focuses on implementation of a prototype electrocardiography (ECG) system which replaces wired connections between sensor points and a central node with wireless links. Successful implementation of the final system would be of benefit to all involved in the use of ECG as access to and movement of the patient would not be impeded by the physical constraints imposed by the cables. Most aspects of the design would also be portable to other sensor applications, making the work relevant to a vast range of systems where movement of sensors is desirable and constrained by hard-wired links.

  10. Computationally efficient sub-band coding of ECG signals.

    Science.gov (United States)

    Husøy, J H; Gjerde, T

    1996-03-01

    A data compression technique is presented for the compression of discrete time electrocardiogram (ECG) signals. The compression system is based on sub-band coding, a technique traditionally used for compressing speech and images. The sub-band coder employs quadrature mirror filter banks (QMF) with up to 32 critically sampled sub-bands. Both finite impulse response (FIR) and the more computationally efficient infinite impulse response (IIR) filter banks are considered as candidates in a complete ECG coding system. The sub-bands are threshold, quantized using uniform quantizers and run-length coded. The output of the run-length coder is further compressed by a Huffman coder. Extensive simulations indicate that 16 sub-bands are a suitable choice for this application. Furthermore, IIR filter banks are preferable due to their superiority in terms of computational efficiency. We conclude that the present scheme, which is suitable for real time implementation on a PC, can provide compression ratios between 5 and 15 without loss of clinical information.

  11. Ubiquitous wireless ECG recording: a powerful tool physicians should embrace.

    Science.gov (United States)

    Saxon, Leslie A

    2013-04-01

    The use of smart phones has increased dramatically and there are nearly a billion users on 3G and 4G networks worldwide. Nearly 60% of the U.S. population uses smart phones to access the internet, and smart phone sales now surpass those of desktop and laptop computers. The speed of wireless communication technology on 3G and 4G networks and the widespread adoption and use of iOS equipped smart phones (Apple Inc., Cupertino, CA, USA) provide infrastructure for the transmission of wireless biomedical data, including ECG data. These technologies provide an unprecedented opportunity for physicians to continually access data that can be used to detect issues before symptoms occur or to have definitive data when symptoms are present. The technology also greatly empowers and enables the possibility for unprecedented patient participation in their own medical education and health status as well as that of their social network. As patient advocates, physicians and particularly cardiac electrophysiologists should embrace the future and promise of wireless ECG recording, a technology solution that can truly scale across the global population. © 2013 Wiley Periodicals, Inc.

  12. BIOACCESSIBILITY TESTS ACCURATELY ESTIMATE ...

    Science.gov (United States)

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from five Pb-contaminated Superfund sites had relative bioavailabilities from 33%-63%, with a mean of about 50%. Treatment of two of the soils with P significantly reduced the bioavailability of Pb. The bioaccessibility of the Pb in the test soils was then measured in six in vitro tests and regressed on bioavailability. They were: the “Relative Bioavailability Leaching Procedure” (RBALP) at pH 1.5, the same test conducted at pH 2.5, the “Ohio State University In vitro Gastrointestinal” method (OSU IVG), the “Urban Soil Bioaccessible Lead Test”, the modified “Physiologically Based Extraction Test” and the “Waterfowl Physiologically Based Extraction Test.” All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the RBALP pH 2.5 and OSU IVG tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter 24%, or present as Pb sulfate 18%. Ad

  13. 基于 Kal man 滤波的人体心电跟踪监测系统设计%Design of human ECG monitoring system based on Kalman filter

    Institute of Scientific and Technical Information of China (English)

    刘俊杰; 柳桂国; 宋栓军

    2016-01-01

    Aimed at ECG health care for families ,and improving the accuracy of the low power monitoring ECG monitoring system ,an ECG monitoring system using Kalman filter is designed and implemented .The weak ECG signals are extracted by electrodes and ECG collecting line of three lead ,and then filtered and amplified through the analog front using AD8232 , then the STM32 processor is used for Kalman filter processing . At last , the actual ECG characteristics of biological electrical signals and heart rate are got in the LCD .Tested by the experimental prototype , under the condition of the human body being quiet ,the result in the LCD is clear and stable ,and can reflect the actual electrical characteristics of the human body .The results show that the design successfully completed the ECG signal filter processing ,can meet the needs of home ECG monitoring ,which means a certain reference value for family medical equipment .%针对家庭心电健康监护,以及提高低功耗心电监测系统监测的准确性,设计并实现了一种采用卡尔曼滤波的心电监测系统。该系统采用AD8232作为模拟前段对通过电极和三导联心电采集线提取的微弱心电信号进行滤波放大,再经STM32处理器进行卡尔曼滤波处理,最终在LCD得到清晰稳定的生物电信号及心率。经实验样机初步测试,在人体保持安静的情况下,LCD显示的心电信号清晰稳定,能够反映人体实际心电特征。结果表明该设计较好地完成了心电信号的滤波处理,能够满足家庭心电监测的需求,对于家庭医疗设备有一定参考价值。

  14. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T. [Dept. Medical Radiology, Inst. of Diagnostic Radiology, Univ. Hospital Zurich (Switzerland)

    2004-04-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P<0.05). The summary scores for visualization of bronchial segments for different diastolic reconstructions did not differ significantly. The effective radiation dose and the SNR were significantly higher with the ECG-gated acquisition technique (P<0.05). Conclusion: The bronchial tree is significantly better visualized when using non-ECG-gated MDCT compared to ECG-gated MDCT. Additionally, non-ECG-gated techniques require less radiation exposure. Thus, the current retrospective ECG-gating technique does not provide any additional benefit for 3D visualization of the bronchial tree and VB. (orig.) [German] Ziel: Untersuchung des Einflusses der retrospektiven EKG-Synchronisierung auf

  15. A Low-Power Bio-Potential Acquisition System with Flexible PDMS Dry Electrodes for Portable Ubiquitous Healthcare Applications

    Science.gov (United States)

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-01-01

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system. PMID:23459390

  16. A Low-Power Bio-Potential Acquisition System with Flexible PDMS Dry Electrodes for Portable Ubiquitous Healthcare Applications

    Directory of Open Access Journals (Sweden)

    Jin-Chern Chiou

    2013-03-01

    Full Text Available This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS process, a commercial microcontroller (MSP430F149, and a secure digital (SD card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system.

  17. An automated ECG system in a large hospital: coding, storage and retrieval of tracings

    NARCIS (Netherlands)

    Meijler, F.L.; Robles de Medina, E.O.; Helder, J.C.

    1975-01-01

    This paper describes an automated ECG-system as it is used in the 1000-bed University Hospital Utrecht, The Netherlands. The system involves a "hybride" approach, combining computer analysis of the ECG by means of the Pipberger program with the reading by a cardiologist via a specially developed cod

  18. Detectability of motions in AAA with ECG-gated CTA: A quantitative study

    NARCIS (Netherlands)

    Klein, Almar; Oostveen, Luuk J.; Greuter, Marcel J.W.; Hoogeveen, Yvonne; Schultze Kool, Leo J.; Slump, Cornelis H.; Renema, W. Klaas Jan

    2009-01-01

    Purpose: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal

  19. Detectability of motions in AAA with ECG-gated CTA: a quantitative study.

    NARCIS (Netherlands)

    Klein, A.; Oostveen, L.J.; Greuter, M.J.; Hoogeveen, Y.L.; Kool, L.J.; Slump, C.H.; Renema, W.K.J.

    2009-01-01

    PURPOSE: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal

  20. Detectability of motions in AAA with ECG-gated CTA : A quantitative study

    NARCIS (Netherlands)

    Klein, Almar; Oostveen, Luuk J.; Greuter, Marcel J. W.; Hoogeveen, Yvonne; Kool, Leo J. Schultze; Slump, Cornelis H.; Renema, W. Klaas Jan

    2009-01-01

    Purpose: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal

  1. Simple electrocardiogram (ECG) signal analyzer for homecare system among the elderly.

    Science.gov (United States)

    Lin, Liuh-Chii; Yeh, Yun-Chi; Ho, Kuei-Jung

    2015-01-01

    This study presents a simple electrocardiogram (ECG) signal analyzer for homecare system among the elderly. It can transmit ECG signals of patient around his/her house through Bluetooth to computers in house. ECG signals are analyzed by the computer. If abnormal case of heartbeat is found, the emergency call is automatically dialed. Meanwhile, the determined heartbeat case of ECG signals will be forwarded to patient's MD through internet. Therefore, the patient can do whatever he/she wants around his/her house with our proposed simple cardiac arrhythmias signal analyzer. The proposed consists of five major processing stages: (i) preprocessing stage for enlarging ECG signals' amplitude and eliminating noises; (ii) ECG signal transmitter/receiver stage, ECG signals are transmitted through Bluetooth to the signal receiver in patient's house; (iii) QRS extraction stage for detecting QRS waveform using the Difference Operation Method (DOM) method; (iv) qualitative features stage for qualitative feature selection on ECG signals; and (v) classification stage for determining patient's heartbeat cases using the Principal Component Analysis (PCA) method. In the experiment, the total classification accuracy (TCA) was approximately 93.19% in average.

  2. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    Science.gov (United States)

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  3. An automated ECG system in a large hospital: coding, storage and retrieval of tracings

    NARCIS (Netherlands)

    Meijler, F.L.; Robles de Medina, E.O.; Helder, J.C.

    1975-01-01

    This paper describes an automated ECG-system as it is used in the 1000-bed University Hospital Utrecht, The Netherlands. The system involves a "hybride" approach, combining computer analysis of the ECG by means of the Pipberger program with the reading by a cardiologist via a specially developed cod

  4. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    Science.gov (United States)

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis.

  5. Interactive Videoconference Supported Teaching in Undergraduate Nursing: A Case Study for ECG

    Science.gov (United States)

    Celikkan, Ufuk; Senuzun, Fisun; Sari, Dilek; Sahin, Yasar Guneri

    2013-01-01

    This paper describes how interactive videoconference can benefit the Electrocardiography (ECG) skills of undergraduate nursing students. We have implemented a learning system that interactively transfers the visual and practical aspects of ECG from a nursing skills lab into a classroom where the theoretical part of the course is taught. The…

  6. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    Science.gov (United States)

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  7. Left Ventricular Hypertrophy: An allometric comparative analysis of different ECG markers

    Science.gov (United States)

    Bonomini, M. P.; Ingallina, F.; Barone, V.; Valentinuzzi, M. E.; Arini, P. D.

    2011-12-01

    Allometry, in general biology, measures the relative growth of a part in relation to the whole living organism. Left ventricular hypertrophy (LVH) is the heart adaptation to excessive load (systolic or diastolic). The increase in left ventricular mass leads to an increase in the electrocardiographic voltages. Based on clinical data, we compared the allometric behavior of three different ECG markers of LVH. To do this, the allometric fit AECG = δ + β (VM) relating left ventricular mass (estimated from ecocardiographic data) and ECG amplitudes (expressed as the Cornell-Voltage, Sokolow and the ECG overall voltage indexes) were compared. Besides, sensitivity and specifity for each index were analyzed. The more sensitive the ECG criteria, the better the allometric fit. In conclusion: The allometric paradigm should be regarded as the way to design new and more sensitive ECG-based LVH markers.

  8. Relative Amplitude based Features of characteristic ECG-Peaks for Identification of Coronary Artery Disease

    Science.gov (United States)

    Gohel, Bakul; Tiwary, U. S.; Lahiri, T.

    Coronary artery disease or Myocardial Infarction is the leading cause of death and disability in the world. ECG is widely used as a cheap diagnostic tool for diagnosis of coronary artery disease but has low sensitivity with the present criteria based on ST-segment, T wave and Q wave changes. So to increase the sensitivity of the ECG we have introduced relative amplitude based new features of characteristic ‘R’ and ‘S’ ECG-peaks between two leads. Relative amplitude based features shows remarkable capability in discriminating Myocardial Infarction and Healthy pattern using backpropogation neural network classifier yield results with 81.82% sensitivity and 81.82% specificity. Also relative amplitude might be an efficient method in minimizing the effect of body composition on ECG amplitude based features without use of any information from other than ECG

  9. Application of the Wireless Digital Transmission Technology in Remote ECG Monitoring System

    Institute of Scientific and Technical Information of China (English)

    Xu,Lixin; Li,Qingliang; Chen,Zhen; Qi,Xinbo; Zhang,Xincheng

    2005-01-01

    Heart disease is one of the main diseases menace human' s health. The limited monitoring ability and limited serving ability are shortcomings of the existing remote ECG (electrocardiograph) monitoring system. It is practical to bring ECG monitoring from hospital to home. A new method is introduced that the application of wireless digital transmission technology in remote ECG monitoring system. In the system, the portable ECG monitoring device to collect and transmit patient""s electrocardiogram signals and the device to transmit and receive ECG signals are designed by using the PTR2000. The method solves the remote collection and transmission of patient's electrocardiogram signals, and creates the condition of the transmitting of patient"" s electrocardiogram signals through the Broadband network.

  10. Application of the Wireless Digital Transmission Technology in Remote ECG Monitoring System

    Institute of Scientific and Technical Information of China (English)

    Xu,Lixin; Li,Qingliang; Chen,Zhen; Qi,Xinbo; Zhang,Xincheng

    2005-01-01

    Heart disease is one of the main diseases menace human's health. The limited monitoring ability and limited serving ability are shortcomings of the existing remote ECG (electrocardiograph) monitoring system. It is practical to bring ECG monitoring from hospital to home. A new method is introduced that the application of wireless digital transmission technology in remote ECG monitoring system. In the system, the portable ECG monitoring device to collect and transmit patient's electrocardiogram signals and the device to transmit and receive ECG signals are designed by using the PTR2000. The method solves the remote collection and transmission of patient s electrocardiogram signals, and creates the condition of the transmitting of patient's electrocardiogram signals through the Broadband network.

  11. ECG Signal Processing, Classification and Interpretation A Comprehensive Framework of Computational Intelligence

    CERN Document Server

    Pedrycz, Witold

    2012-01-01

    Electrocardiogram (ECG) signals are among the most important sources of diagnostic information in healthcare so improvements in their analysis may also have telling consequences. Both the underlying signal technology and a burgeoning variety of algorithms and systems developments have proved successful targets for recent rapid advances in research. ECG Signal Processing, Classification and Interpretation shows how the various paradigms of Computational Intelligence, employed either singly or in combination, can produce an effective structure for obtaining often vital information from ECG signals. Neural networks do well at capturing the nonlinear nature of the signals, information granules realized as fuzzy sets help to confer interpretability on the data and evolutionary optimization may be critical in supporting the structural development of ECG classifiers and models of ECG signals. The contributors address concepts, methodology, algorithms, and case studies and applications exploiting the paradigm of Comp...

  12. Design of Low Power Algorithms for Automatic Embedded Analysis of Patch ECG Signals

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt

    The diagnosis of cardiac arrhythmias often depends on information from long-term ambulatory electrocardiographic (ECG) monitoring. For several decades, these recordings have been obtained by wired Holter recorders. However, to overcome some of the known disadvantages of the old technologies......, several different cable-free wireless patch-type ECG recorders have recently reached the market. One of these recorders is the ePatch designed by the Danish company DELTA. The extended monitoring period available with the patch recorders has demonstrated to increase the diagnostic yield of outpatient ECG...... monitoring. Furthermore, the patch recorders facilitate the possibility of outpatient ECG monitoring in new clinically relevant areas, e.g. telemedicine monitoring of cardiac patients in their homes. Some of these new applications could benefit from real-time embedded interpretation of the recorded ECGs...

  13. Simulations and design of microfabricated interdigitated electrodes for use in a gold nanoparticle enhanced biosensor.

    Science.gov (United States)

    Hermansen, Peter; MacKay, Scott; Wishart, David; Jie Chen

    2016-08-01

    Microfabricated interdigitated electrode chips have been designed for use in a unique gold-nanoparticle based biosensor system. The use of these electrodes will allow for simple, accurate, inexpensive, and portable biosensing, with potential applications in diagnostics, medical research, and environmental testing. To determine the optimal design for these electrodes, finite element analysis simulations were carried out using COMSOL Multiphysics software. The results of these simulations determined some of the optimal design parameters for microfabricating interdigitated electrodes as well as predicting the effects of different electrode materials. Finally, based on the results of these simulations two different kinds of interdigitated electrode chips were made using photolithography.

  14. Boundary element analysis of the directional sensitivity of the concentric EMG electrode

    DEFF Research Database (Denmark)

    Henneberg, Kaj-åge; R., Plonsey

    1993-01-01

    Assessment of the motor unit architecture based on concentric electrode motor unit potentials requires a thorough understanding of the recording characteristics of the concentric EMG electrode. Previous simulation studies have attempted to include the effect of EMG electrodes on the recorded...... waveforms by uniformly averaging the tissue potential at the coordinates of one- or two-dimensional electrode models. By employing the boundary element method, this paper improves earlier models of the concentric EMG electrode by including an accurate geometric representation of the electrode, as well...

  15. Feasibility of in utero telemetric fetal ECG monitoring in a lamb model.

    Science.gov (United States)

    Hermans, Bart; Lewi, Liesbeth; Jani, Jacques; De Buck, Frederik; Deprest, Jan; Puers, Robert

    2008-01-01

    If fetal ECG (fECG) devices could be miniaturized sufficiently, one could consider their implantation at the time of fetal surgery to allow permanent monitoring of the fetus and timely intervention in the viable period. We set up an experiment to evaluate the feasibility of in utero direct fECG monitoring and telemetric transmission using a small implantable device in a lamb model. A 2-lead miniature ECG sensor (volume 1.9 cm(3); weight 3.9 g) was subcutaneously implanted in 2 fetal lambs at 122 days gestation (range 119-125; term 145 days). The ECG sensor can continuously register and transmit fECG. The signal is captured by an external receiving antenna taped to the maternal abdominal wall. We developed dedicated software running on a commercial laptop for on-line analysis of the transmitted fECG signal. This was a noninterventional study, i.e. daily readings of the fECG signal were done without clinical consequences to the observations. fECG could be successfully registered, transmitted by telemetry and analyzed from the moment of implantation till term birth in one case (24 days). In the second case, unexplained in utero fetal death occurred 12 days after implantation. In this subject, agonal fECG changes were recorded. An implanted miniature (signal in third-trimester fetal lambs. The telemetric signal could be picked up by an external antenna located within a 20-cm range. In this experiment, this was achieved through taping the external receiver to the maternal abdomen. Any acquired signal could be transmitted to a commercially available laptop that could perform on-line analysis of the signal. (c) 2008 S. Karger AG, Basel.

  16. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  17. A fast and accurate FPGA based QRS detection system.

    Science.gov (United States)

    Shukla, Ashish; Macchiarulo, Luca

    2008-01-01

    An accurate Field Programmable Gate Array (FPGA) based ECG Analysis system is described in this paper. The design, based on a popular software based QRS detection algorithm, calculates the threshold value for the next peak detection cycle, from the median of eight previously detected peaks. The hardware design has accuracy in excess of 96% in detecting the beats correctly when tested with a subset of five 30 minute data records obtained from the MIT-BIH Arrhythmia database. The design, implemented using a proprietary design tool (System Generator), is an extension of our previous work and uses 76% resources available in a small-sized FPGA device (Xilinx Spartan xc3s500), has a higher detection accuracy as compared to our previous design and takes almost half the analysis time in comparison to software based approach.

  18. Pulmonary artery and right ventricle assessment in pulmonary hypertension. Correlation between functional parameters of ECG-gated CT and right-side heart catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Abel, Elodie; Jankowski, Adrien [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Pison, Christophe [Clinique univ. de pneumologie, CHU Grenoble (France); Bosson, Jean Luc [Dept. of Statistics, CIC, CHU Grenoble (France); Bouvaist, Helene [Clinique univ. de cardiologie, CHU Grenoble (France); Ferretti, Gilbert R. [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Univ. J. Fourier, Grenoble (France); INSERM U 823, Inst. A. Bonniot, la Tronche (France)], e-mail: gferretti@chu-grenoble.fr

    2012-09-15

    Background: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. Purpose: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. Material and Methods: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. Results: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P 0.005) correlated equally with RHC-CO. Conclusion: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for

  19. Groundwater recharge: Accurately representing evapotranspiration

    CSIR Research Space (South Africa)

    Bugan, Richard DH

    2011-09-01

    Full Text Available Groundwater recharge is the basis for accurate estimation of groundwater resources, for determining the modes of water allocation and groundwater resource susceptibility to climate change. Accurate estimations of groundwater recharge with models...

  20. Performance of short ECG recordings twice daily to detect paroxysmal atrial fibrillation in stroke and transient ischemic attack patients

    DEFF Research Database (Denmark)

    Poulsen, Mai B; Binici, Zeynep; Dominguez Vall-Lamora, Maria Helena

    2016-01-01

    AIMS: Prolonged cardiac monitoring after stroke is recommended though there is no consensus on optimal methods. Short-term ECG recordings with a "thumb-ECG" device have shown promising preliminary results regarding effectiveness and cost benefit. We aimed to examine the performance of thumb-ECG a...

  1. An awareness approach to analyze ECG streaming data.

    Science.gov (United States)

    Don, S; Chung, Duckwon; Choi, Eunmi; Min, Dugki

    2013-04-01

    Real-time remote health monitoring systems are experiencing tremendous advancement resulting from improvements in low power, reliable sensors; yet they are still constrained to low-level interpretation. Automatic data analysis continues to be a tedious task due to a lack of efficient, reliable platforms for data analysis. In this paper, we present a system for monitoring patients remotely by emphasizing the strength of Complex Event Processing (CEP) and Situation Awareness. In this approach, the system makes decisions in a declarative way, which helps medical experts to understand the situation in a more realistic manner. The primary objective of this paper is to explicate the different components inside the system. To verify the technical feasibility of each component, the proposed system is implemented and tested using ECG data.

  2. [ECG indices in dogs after inhalation of 239Pu].

    Science.gov (United States)

    Karpova, V N

    1985-11-01

    Dogs of both sexes aged 2 to 4 were subjected to inhalation inoculation with polymer 239Pu or submicron 239PuO2 aerosols in amounts close to acute, subacute and chronically effective ones. ECG was recorded in standard, amplified and single leads (V3). All calculations were done by lead II. Signs of the right heart overburdening were noted in the presence of the P-pulmonale complex, deep S1 wave or cardiac electrical axis of SI-SII-SIII type. Signs of the right heart overburdening were revealed after inhalation of polimer 239Pu (70%). The absence of similar changes in damage caused by 239Pu could be attributed to its fast resorption from the lungs resulting in more moderate lesion of the respiratory organs.

  3. Microcontroller-based underwater acoustic ECG telemetry system.

    Science.gov (United States)

    Istepanian, R S; Woodward, B

    1997-06-01

    This paper presents a microcontroller-based underwater acoustic telemetry system for digital transmission of the electrocardiogram (ECG). The system is designed for the real time, through-water transmission of data representing any parameter, and it was used initially for transmitting in multiplexed format the heart rate, breathing rate and depth of a diver using self-contained underwater breathing apparatus (SCUBA). Here, it is used to monitor cardiovascular reflexes during diving and swimming. The programmable capability of the system provides an effective solution to the problem of transmitting data in the presence of multipath interference. An important feature of the paper is a comparative performance analysis of two encoding methods, Pulse Code Modulation (PCM) and Pulse Position Modulation (PPM).

  4. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators

    Directory of Open Access Journals (Sweden)

    Dotsinsky Ivan

    2005-11-01

    Full Text Available Abstract Background Public access defibrillators (PADs are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Method Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed. This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. Results The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. Conclusion The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression.

  5. True unipolar ECG machine for Wilson Central Terminal measurements.

    Science.gov (United States)

    Gargiulo, Gaetano D

    2015-01-01

    Since its invention (more than 80 years ago), modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle) for half of the signals. This reference, known by the name of "Wilson Central Terminal" in honor of its inventor, is obtained by averaging the three active limb electrode voltages measured with respect to the return ground electrode. However, concerns have been raised by researchers about problems (biasing and misdiagnosis) associated with the ambiguous value and behavior of this reference voltage, which requires perfect and balanced contact of at least four electrodes to work properly. The Wilson Central Terminal has received scant research attention in the last few decades even though consideration of recent widespread medical practice (limb electrodes are repositioned closer to the torso for resting electrocardiography) has also sparkled concerns about the validity and diagnostic fitness of leads not referred to the Wilson Central Terminal. Using a true unipolar electrocardiography device capable of precisely measuring the Wilson Central Terminal, we show its unpredictable variability during the cardiac cycle and confirm that the integrity of cardinal leads is compromised as well as the Wilson Central Terminal when limb electrodes are placed close to the torso.

  6. True Unipolar ECG Machine for Wilson Central Terminal Measurements

    Directory of Open Access Journals (Sweden)

    Gaetano D. Gargiulo

    2015-01-01

    Full Text Available Since its invention (more than 80 years ago, modern electrocardiography has employed a supposedly stable voltage reference (with little variation during the cardiac cycle for half of the signals. This reference, known by the name of “Wilson Central Terminal” in honor of its inventor, is obtained by averaging the three active limb electrode voltages measured with respect to the return ground electrode. However, concerns have been raised by researchers about problems (biasing and misdiagnosis associated with the ambiguous value and behavior of this reference voltage, which requires perfect and balanced contact of at least four electrodes to work properly. The Wilson Central Terminal has received scant research attention in the last few decades even though consideration of recent widespread medical practice (limb electrodes are repositioned closer to the torso for resting electrocardiography has also sparkled concerns about the validity and diagnostic fitness of leads not referred to the Wilson Central Terminal. Using a true unipolar electrocardiography device capable of precisely measuring the Wilson Central Terminal, we show its unpredictable variability during the cardiac cycle and confirm that the integrity of cardinal leads is compromised as well as the Wilson Central Terminal when limb electrodes are placed close to the torso.

  7. Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Zhaoping; Wang, Ximing; Duan, Yanhua; Wu, Lebin; Wu, Dawei; Chao, Baoting; Liu, Cheng; Xu, Zhuodong [Shandong University, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Li, Hongxin; Liang, Fei [Shandong Provincial Hospital, Department of Cardiovascular Surgery, Jinan, Shandong (China); Xu, Jian; Chen, Jiuhong [Siemens. Ltd. China, CT Research Collaboration, Beijing (China)

    2010-10-15

    To explore the clinical value of low-dose prospective ECG-triggering dual-source CT (DSCT) angiography in infants and children with complex congenital heart disease (CHD) compared with transthoracic echocardiography (TTE). Thirty-five patients (mean age: 16 months, range: 2 months to 6 years; male 15; mean weight: 12 kg) underwent low-dose prospective ECG-triggering DSCT angiography and TTE. Surgeries were performed in 29 patients, and conventional cardiac angiography (CCA) was performed in 8 patients. The accuracy was calculated based on the surgical and/or CCA findings. The overall imaging quality was evaluated on a five-point scale. A total of 146 separate cardiovascular deformities were confirmed. DSCT missed three atrial septal defects and a patent ductus arteriosus. The accuracy of DSCT angiography and TTE was 97.3% (142/146) and 92.5% (135/146), respectively. Overall test parameters for DSCT angiography and TTE were similar (sensitivity, 97.3% vs 92.5%; specificity, 99.8% vs 99.8%). The average subjective image quality score was 4.3 {+-} 0.7. The mean effective dose was 0.38 {+-} 0.09 mSv. Prospective ECG-triggering DSCT angiography with a very low effective radiation dose allows the accurate diagnosis of anomalies in infants and children with complex CHD compared with TTE. It has great promise to become a commonly used second-line technique for complex CHD. (orig.)

  8. The Role of Conventional and Right-Sided ECG Screening for Subcutaneous ICD in a Tetralogy of Fallot Population.

    Science.gov (United States)

    Alonso, Pau; Osca, Joaquín; Cano, Oscar; Pimenta, Pedro; Andrés, Ana; Yagüe, Jaime; Millet, José; Rueda, Joaquín; Sancho-Tello, María José

    2017-02-01

    Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population. © 2017 Wiley Periodicals, Inc.

  9. Prevalence of Brugada-type ECG pattern and early ventricular repolarization pattern in Tunisian athletes

    Directory of Open Access Journals (Sweden)

    Ouali S

    2011-04-01

    Full Text Available Sana Ouali1, Helmi Ben Salem1, Sami Hammas1, Elyes Neffeti1, Fahmi Remedi1, Abdallah Mahdhaoui2, Essia Boughzela1, Rafik Mankai31Department of Cardiology, Sahloul Hospital, Sousse, Tunisia; 2Department of Cardiology, Farhat Hached, Sousse, Tunisia; 3Central Sports Medicine Centre of El Menzah, TunisiaIntroduction: No data regarding the prevalence of the Brugada-type electrocardiogram (ECG pattern and the early ventricular repolarization pattern (ERP in the North African population were available. The aims of this study were to determine the frequency of Brugada-type ECG pattern and ERP in Tunisia and to evaluate ECG descriptors of ventricular repolarization in a population of athletes.Methods: Over a 2-year period, resting 12-lead ECG recordings were analyzed from athletes (n = 540; 348 males; age 18.3 ± 2.4 years. Brugada-type ECG pattern was defined as Type 1, 2, or 3, and ERP was characterized by an elevation of the J point in the inferior and/or lateral leads. The population was divided into three groups of athletes: ERP group; Brugada-type ECG pattern group; and control group, with neither ERP nor Brugada ECG pattern. Clinical and electrocardiographic parameters were compared among the study groups.Results: Nine subjects (1.66% had a Brugada-type ECG pattern. None of them had the coved-type, 3 (0.6% had the Type 2, and 6 (1.1% had the Type 3. All subjects were asymptomatic. A Brugada-type ECG pattern was observed in seven males. No female had the Type 2 Brugada ECG pattern. ECG parameters were similar among Brugada-type ECG pattern and control athletes. ERP (119 subjects, 22% was obtained in 98 males. Heart rate was lower, the QRS duration shorter and QT and Tpeak–Tend intervals were longer in ERP than control groups.Conclusion: The results indicate that the frequency of the Brugada-type ECG pattern and ERP were respectively 1.66% and 22.00% in athletes, being more prevalent in males. The ERP group experienced shorter QRS duration and

  10. Durable fuel electrode

    DEFF Research Database (Denmark)

    2017-01-01

    the composite. The invention also relates to the use of the composite as a fuel electrode, solid oxide fuel cell, and/or solid oxide electrolyser. The invention discloses a composite for an electrode, comprising a three-dimensional network of dispersed metal particles, stabilised zirconia particles and pores...

  11. Membrane Bioprobe Electrodes

    Science.gov (United States)

    Rechnitz, Garry A.

    1975-01-01

    Describes the design of ion selective electrodes coupled with immobilized enzymes which operate either continuously or on drop-sized samples. Cites techniques for urea, L-phenylalanine and amygdalin. Micro size electrodes for use in single cells are discussed. (GH)

  12. Membrane Bioprobe Electrodes

    Science.gov (United States)

    Rechnitz, Garry A.

    1975-01-01

    Describes the design of ion selective electrodes coupled with immobilized enzymes which operate either continuously or on drop-sized samples. Cites techniques for urea, L-phenylalanine and amygdalin. Micro size electrodes for use in single cells are discussed. (GH)

  13. Evaluation of the fetal QT interval using non-invasive fetal ECG technology.

    Science.gov (United States)

    Behar, Joachim; Zhu, Tingting; Oster, Julien; Niksch, Alisa; Mah, Douglas Y; Chun, Terrence; Greenberg, James; Tanner, Cassandre; Harrop, Jessica; Sameni, Reza; Ward, Jay; Wolfberg, Adam J; Clifford, Gari D

    2016-09-01

    Non-invasive fetal electrocardiography (NI-FECG) is a promising alternative continuous fetal monitoring method that has the potential to allow morphological analysis of the FECG. However, there are a number of challenges associated with the evaluation of morphological parameters from the NI-FECG, including low signal to noise ratio of the NI-FECG and methodological challenges for getting reference annotations and evaluating the accuracy of segmentation algorithms. This work aims to validate the measurement of the fetal QT interval in term laboring women using a NI-FECG electrocardiogram monitor. Fetal electrocardiogram data were recorded from 22 laboring women at term using the NI-FECG and an invasive fetal scalp electrode simultaneously. A total of 105 one-minute epochs were selected for analysis. Three pediatric electrophysiologists independently annotated individual waveforms and averaged waveforms from each epoch. The intervals measured on the averaged cycles taken from the NI-FECG and the fetal scalp electrode showed a close agreement; the root mean square error between all corresponding averaged NI-FECG and fetal scalp electrode beats was 13.6 ms, which is lower than the lowest adult root mean square error of 16.1 ms observed in related adult QT studies. These results provide evidence that NI-FECG technology enables accurate extraction of the fetal QT interval.

  14. Assurance of energy efficiency and data security for ECG transmission in BASNs.

    Science.gov (United States)

    Ma, Tao; Shrestha, Pradhumna Lal; Hempel, Michael; Peng, Dongming; Sharif, Hamid; Chen, Hsiao-Hwa

    2012-04-01

    With the technological advancement in body area sensor networks (BASNs), low cost high quality electrocardiographic (ECG) diagnosis systems have become important equipment for healthcare service providers. However, energy consumption and data security with ECG systems in BASNs are still two major challenges to tackle. In this study, we investigate the properties of compressed ECG data for energy saving as an effort to devise a selective encryption mechanism and a two-rate unequal error protection (UEP) scheme. The proposed selective encryption mechanism provides a simple and yet effective security solution for an ECG sensor-based communication platform, where only one percent of data is encrypted without compromising ECG data security. This part of the encrypted data is essential to ECG data quality due to its unequally important contribution to distortion reduction. The two-rate UEP scheme achieves a significant additional energy saving due to its unequal investment of communication energy to the outcomes of the selective encryption, and thus, it maintains a high ECG data transmission quality. Our results show the improvements in communication energy saving of about 40%, and demonstrate a higher transmission quality and security measured in terms of wavelet-based weighted percent root-mean-squared difference.

  15. [The relationship between conventional ECG and the culprit coronary artery in acute myocardial infarct].

    Science.gov (United States)

    César, L A; Moretti, M A; Ramires, J A; Nussbacher, A; Consolim, F M; Moffa, P J; da Luz, P L; Bellotti, G M; Pileggi, F

    1994-08-01

    To evaluate electrocardiogram (ECG) in detecting acute myocardial infarction (AMI) during the first 12 hours of symptoms and its relationship to the culprit coronary artery. We studied 68 patients aged 55.6 (30 to 76) years, 61 males, with AMI confirmed by elevated CKMB isoenzyme and cinecoronariography (CINE). In all of them we obtained two ECG: first (i), with or = 5 days during evolution. ECG were analyzed in order to disclose up and downward ST-T segments > or = 1 mm, new Q waves > or = 0.04 s and R/S > or = 1 plus downward ST-T segment in leads V1 and V2. Then we have done correlation between these and the culprit coronary lesions at CINE. The culprit coronary lesions were: right coronary artery (RCA) in 16, left circumflex (LC) in 26 and left anterior descending (LAD) in 31 cases. According to the ECG, the RCA determined inferior AMI in all patients and the LC only in 62% of cases. Posterior AMI due to LC was seen in 81% of cases at ECG and, associated with lateral AMI, in 52%. Lone lateral AMI was seen in 5% and true posterior in 14% of cases, all of them due to LC. False negative ECG (i) in AMI is in fact due to LC occlusion which, frequently, causes posterior wall more then inferior wall myocardial infarction at ECG.

  16. An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare.

    Science.gov (United States)

    Yang, Zhe; Zhou, Qihao; Lei, Lei; Zheng, Kan; Xiang, Wei

    2016-12-01

    Public healthcare has been paid an increasing attention given the exponential growth human population and medical expenses. It is well known that an effective health monitoring system can detect abnormalities of health conditions in time and make diagnoses according to the gleaned data. As a vital approach to diagnose heart diseases, ECG monitoring is widely studied and applied. However, nearly all existing portable ECG monitoring systems cannot work without a mobile application, which is responsible for data collection and display. In this paper, we propose a new method for ECG monitoring based on Internet-of-Things (IoT) techniques. ECG data are gathered using a wearable monitoring node and are transmitted directly to the IoT cloud using Wi-Fi. Both the HTTP and MQTT protocols are employed in the IoT cloud in order to provide visual and timely ECG data to users. Nearly all smart terminals with a web browser can acquire ECG data conveniently, which has greatly alleviated the cross-platform issue. Experiments are carried out on healthy volunteers in order to verify the reliability of the entire system. Experimental results reveal that the proposed system is reliable in collecting and displaying real-time ECG data, which can aid in the primary diagnosis of certain heart diseases.

  17. Low-power analog integrated circuits for wireless ECG acquisition systems.

    Science.gov (United States)

    Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh

    2012-09-01

    This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.

  18. Using simulated noise to define optimal QT intervals for computer analysis of ambulatory ECG.

    Science.gov (United States)

    Tikkanen, P E; Sellin, L C; Kinnunen, H O; Huikuri, H V

    1999-01-01

    The ambulatory electrocardiogram (ECG) is an important medical tool, not only for diagnosis of adverse cardiac events, but also to predict the risk of such events occurring. The 24-hour ambulatory ECG has certain problems and drawbacks because the signal is corrupted by noise from various sources and also several other conditions which may alter the ECG morphology. We have developed a Windows based program for the computer analysis of ambulatory ECG which attempts to address these problems. The software includes options for importing ECG data, different methods of waveform analysis, data-viewing, and exporting the extracted time series. In addition, the modular structure allows for flexible maintenance and expansion of the software. The ECG was recorded using a Holter device and oversampled to enhance the fidelity of the low sampling rate of the ambulatory ECG. The influence of different sampling rates on the interval variability were studied. The noise sensitivity of the implemented algorithm was tested with several types of simulated noise and the precision of the interval measurement was reported with SD values. Our simulations showed that, in most of the cases, defining the end of QT interval at the maximum of the T wave gave the most precise measurement. The definition of the onset of the ventricular repolarization duration is most precisely made on the maximum or descending maximal slope of the R wave. We also analyzed some examples of time series from patients using power spectrum estimates in order to validate the low level QT interval variability.

  19. Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.

    Science.gov (United States)

    Al-Busaidi, Asiya M; Khriji, Lazhar; Touati, Farid; Rasid, Mohd Fadlee; Mnaouer, Adel Ben

    2017-09-12

    One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.

  20. Classification of a Driver's cognitive workload levels using artificial neural network on ECG signals.

    Science.gov (United States)

    Tjolleng, Amir; Jung, Kihyo; Hong, Wongi; Lee, Wonsup; Lee, Baekhee; You, Heecheon; Son, Joonwoo; Park, Seikwon

    2017-03-01

    An artificial neural network (ANN) model was developed in the present study to classify the level of a driver's cognitive workload based on electrocardiography (ECG). ECG signals were measured on 15 male participants while they performed a simulated driving task as a primary task with/without an N-back task as a secondary task. Three time-domain ECG measures (mean inter-beat interval (IBI), standard deviation of IBIs, and root mean squared difference of adjacent IBIs) and three frequencydomain ECG measures (power in low frequency, power in high frequency, and ratio of power in low and high frequencies) were calculated. To compensate for individual differences in heart response during the driving tasks, a three-step data processing procedure was performed to ECG signals of each participant: (1) selection of two most sensitive ECG measures, (2) definition of three (low, medium, and high) cognitive workload levels, and (3) normalization of the selected ECG measures. An ANN model was constructed using a feed-forward network and scaled conjugate gradient as a back-propagation learning rule. The accuracy of the ANN classification model was found satisfactory for learning data (95%) and testing data (82%).

  1. A semiconductor based electrode

    Energy Technology Data Exchange (ETDEWEB)

    Khamatani, A.; Kobayasi, K.

    1983-03-30

    The semiconductor electrode is submerged into an electrolyte which is held in the illuminated chamber. The other electrode is placed in a dark chamber connected with the channel to be illuminated, which has a partition in the form of a membrane. An electric current flows in the external circuit of the element with illumination of the first electrode. The illuminated electrode is covered with a thin film of a substance which is stable with the action of the electrolyte. The film is made of Si02, A1203, GaN or A1N. The protective coating makes it possible to use materials less stable than Ti02 in a rutile modification, but which have higher characteristics than the GaP, GaAs, CdS and InP, for making the electrode.

  2. Feasibility of tracked electrodes for use in epilepsy surgery

    Science.gov (United States)

    Holmes, David; Brinkmann, Benjamin; Hanson, Dennis; Worrell, Gregory; Robb, Richard; Holton, Leslie

    2016-03-01

    Subdural electrode recording is commonly used to evaluate intractable epilepsy. In order to accurately record electrical activity responsible for seizure, electrodes must be positioned precisely near targets of interest, often indicated preoperatively through imaging studies. To achieve accurate placement, a large craniotomy is used to expose the brain surface. With the intent of limiting the size and improving the location of craniotomy for electrode placement, we examined magnetic tracking for localization of electrode strips. Commercially available electrode strips were attached to specialized magnetic tracking sensors developed by Medtronic plc. In a rigid phantom we evaluated the strips to determine the accuracy of electrode placement on targets. We further conducted an animal study to evaluate the impact of magnetic field interference during data collection. The measured distance between the physical fiducial and lead coil of the electrode strip was 1.32 +/- 1.03mm in the phantom experiments. The tracking system induces a very strong signal in the electrodes in the Very Low Frequency, an International Telecommunication Union (ITU) designated frequency band, from 3 kHz to 30 kHz. The results of the animal experiment demonstrated both tracking feasibility and data collection.

  3. Single Channel Fetal ECG Detection Using LMS and RLS Adaptive Filters

    Institute of Scientific and Technical Information of China (English)

    Alaa Aldoori; Ali Buniya; ZHENG Zheng

    2015-01-01

    ECG is an important tool for the primary diagnosis of heart diseases, which shows the electrophysiology of the heart. In our method, a single maternal abdominal ECG signal is taken as an input signal and the maternal P-QRS-T complexes of original signal is averaged and repeated and taken as a reference signal. LMS and RLS adaptive filters algorithms are applied. The results showed that the fetal ECGs have been successfully detected. The accuracy of Daisy database was up to 84%of LMS and 88%of RLS while PhysioNet was up to 98%and 96%for LMS and RLS respectively.

  4. Evaluation of novel ECG signal processing on quantification of transient ischemia and baseline wander suppression.

    Science.gov (United States)

    Kostic, Marko N; Fakhar, Sina; Foxall, Tom; Drakulic, Budimir S; Krucoff, Mitchell W

    2007-01-01

    The performance assessment of a novel ECG signal processing technology in Fidelity 100 (test) and four modern ECG systems (controls) was conducted. A quantitative evaluation for one control and a test system was done by simultaneous recordings on 54 patients undergoing percutaneous coronary intervention (PCI) and on a biological reference signal from an ECG simulator. A qualitative performance of baseline wander suppression was done on all five systems. The results showed that the Fidelity 100 system provided excellent detection and quantification of transient ischemia and baseline wander suppression.

  5. Real-time ECG emulation: a multiple dipole model for electrocardiography simulation.

    Science.gov (United States)

    Abkai, Ciamak; Hesser, Jürgen

    2009-01-01

    A new model for describing electrocardiography (ECG) is presented, which is based on multiple dipoles compared to standard single dipole approaches in vector electrocardiography. The multiple dipole parameters are derived from real data (e.g. four dipoles from 12-channel ECG) by solving the backward problem of ECG numerically. Results are transformed to a waveform description based on Gaussian mixture for every dimension of each dipole. These compact parameterized descriptors are used for a very realistic real-time simulation applying the forward solution of the proposed model.

  6. Principal component cluster analysis of ECG time series based on Lyapunov exponent spectrum

    Institute of Scientific and Technical Information of China (English)

    WANG Nai; RUAN Jiong

    2004-01-01

    In this paper we propose an approach of principal component cluster analysis based on Lyapunov exponent spectrum (LES) to analyze the ECG time series. Analysis results of 22 sample-files of ECG from the MIT-BIH database confirmed the validity of our approach. Another technique named improved teacher selecting student (TSS) algorithm is presented to analyze unknown samples by means of some known ones, which is of better accuracy. This technique combines the advantages of both statistical and nonlinear dynamical methods and is shown to be significant to the analysis of nonlinear ECG time series.

  7. Low noise multi-channel biopotential wireless data acquisition system for dry electrodes

    Science.gov (United States)

    Pandian, P. S.; Whitchurch, Ashwin K.; Abraham, Jose K.; Bhusan Baskey, Himanshu; Radhakrishnan, J. K.; Varadan, Vijay K.; Padaki, V. C.; Bhasker Rao, K. U.; Harbaugh, R. E.

    2008-03-01

    The bioelectrical potentials generated within the human body are the result of electrochemical activity in the excitable cells of the nervous, muscular or glandular tissues. The ionic potentials are measured using biopotential electrodes which convert ionic potentials to electronic potentials. The commonly monitored biopotential signals are Electrocardiogram (ECG), Electroencephalogram (EEG) and Electromyogram (EMG). The electrodes used to monitor biopotential signals are Ag-AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gels used in biopotential recordings dry out when used for longer durations and add noise to the signals and also prolonged use of gels cause irritations and rashes to skin. Also noises such as motion artifact and baseline wander are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry electrodes are used, where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The major drawback associated with the dry electrodes is the high skin-electrode impedance in the low frequency range between 0.1-120 Hz, which makes it difficult to acquire clean and noise free biopotential signals. The paper presents the design and development of biopotential data acquisition and processing system to acquire biopotential signals from dry electrodes. The electrode-skin-electrode- impedance (ESEI) measurements was carried out for the dry electrodes by impedance spectroscopy. The biopotential signals are processed using an instrumentation amplifier with high CMRR and high input impedance achieved by boot strapping the input terminals. The signals are band limited by means of a second order Butterworth band pass filters to eliminate noise. The processed biopotential signals are digitized

  8. Improving local PCA in pseudo phase space for fetal heart rate estimation from single lead abdominal ECG.

    Science.gov (United States)

    Wei, Zheng; Hongxing, Liu; Jianchun, Cheng

    2011-12-01

    This paper proposes an improved local principal component analysis (LPCA) in pseudo phase space for fetal heart rate estimation from a single lead abdominal ECG signal. The improved LPCA process can extract both the maternal ECG component and the fetal ECG component in an abdominal signal. The instantaneous fetal heart rate can then be estimated from the extracted fetal ECG waveform. Compared with the classical LPCA procedure and another single lead based fetal heart rate estimation method, our improved LPCA method has shown better robustness and efficiency in fetal heart estimation, testing with synthetic ECG signals and a real fetal ECG database from PhysioBank. For the real fetal ECG validating dataset of six long-duration recordings (obtained between the 22(nd) and 40(th) week of gestation), the average accuracy of the improved LPCA method is 84.1%.

  9. A reversed-phase HPLC-UV assay for simultaneous analysis of EGCG and ECG of tea polyphenols in rat plasma

    Institute of Scientific and Technical Information of China (English)

    FU Ting; LIANG Jun; HAN Guo-zhu; L(U) Li; LI Nan

    2008-01-01

    pharmacokinetically behaved as the two-compartment model and first-order kinetics, with t1/2β 122.9 min and 59.2 min, Vd 7.96 L·kg-1 and 1.22 L·kg-1, CL 0.044 L·kg-1·min-1 and 0.015 L·kg-1·min-1 for EGCG and ECG, respectively. Conclusions The method developed in the present study is highly specific, precise, accurate, and suitable for the non-clinical pharmacokinetie study of the TP in rats.

  10. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Bastarrika, Gorka [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Cardiac Imaging Unit, Clinica Univ. de Navarra, Pamplona (Spain)], e-mail: bastarrika@unav.es

    2012-06-15

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 {+-} 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 {+-} 58.3 mL) with respect to ECG-gated CT (142.7 {+-} 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 {+-} 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.

  11. Heart Beat Detection in Noisy ECG Signals Using Statistical Analysis of the Automatically Detected Annotations

    Directory of Open Access Journals (Sweden)

    Andrius Gudiškis

    2015-07-01

    Full Text Available This paper proposes an algorithm to reduce the noise distortion influence in heartbeat annotation detection in electrocardiogram (ECG signals. Boundary estimation module is based on energy detector. Heartbeat detection is usually performed by QRS detectors that are able to find QRS regions in a ECG signal that are a direct representation of a heartbeat. However, QRS performs as intended only in cases where ECG signals have high signal to noise ratio, when there are more noticeable signal distortion detectors accuracy decreases. Proposed algorithm uses additional data, taken from arterial blood pressure signal which was recorded in parallel to ECG signal, and uses it to support the QRS detection process in distorted signal areas. Proposed algorithm performs as well as classical QRS detectors in cases where signal to noise ratio is high, compared to the heartbeat annotations provided by experts. In signals with considerably lower signal to noise ratio proposed algorithm improved the detection accuracy to up to 6%.

  12. Unobtrusive monitoring of ECG-derived features during daily smartphone use.

    Science.gov (United States)

    Kwon, Sungjun; Kang, Seungwoo; Lee, Youngki; Yoo, Chungkuk; Park, Kwangsuk

    2014-01-01

    Heart rate variability (HRV) is known to be one of the representative ECG-derived features that are useful for diverse pervasive healthcare applications. The advancement in daily physiological monitoring technology is enabling monitoring of HRV in people's everyday lives. In this study, we evaluate the feasibility of measuring ECG-derived features such as HRV, only using the smartphone-integrated ECG sensors system named Sinabro. We conducted the evaluation with 13 subjects in five predetermined smartphone use cases. The result shows the potential that the smartphone-based sensing system can support daily monitoring of ECG-derived features; The average errors of HRV over all participants ranged from 1.65% to 5.83% (SD: 2.54~10.87) for five use cases. Also, all of individual HRV parameters showed less than 5% of average errors for the three reliable cases.

  13. ECG Sensor Verification System with Mean-Interval Algorithm for Handling Sport Issue

    Directory of Open Access Journals (Sweden)

    Kuo-Kun Tseng

    2016-01-01

    Full Text Available With the development of biometric verification, we proposed a new algorithm and personal mobile sensor card system for ECG verification. The proposed new mean-interval approach can identify the user quickly with high accuracy and consumes a small amount of flash memory in the microprocessor. The new framework of the mobile card system makes ECG verification become a feasible application to overcome the issues of a centralized database. For a fair and comprehensive evaluation, the experimental results have been tested on public MIT-BIH ECG databases and our circuit system; they confirm that the proposed scheme is able to provide excellent accuracy and low complexity. Moreover, we also proposed a multiple-state solution to handle the heat rate changes of sports problem. It should be the first to address the issue of sports in ECG verification.

  14. Hypertrophic cardiomyopathy: Prevalence, hypertrophy patterns, and their clinical and ECG findings in a hospital at Qatar

    Directory of Open Access Journals (Sweden)

    Sherif M Helmy

    2011-01-01

    Conclusion: The prevalence of HCM in our population group is 0.13% with a male predominance (12:1. There was a diversity of clinical presentation, ECG abnormalities and patterns of LV hypertrophy among HCM patients.

  15. A Human ECG Identification System Based on Ensemble Empirical Mode Decomposition

    Directory of Open Access Journals (Sweden)

    Yi Luo

    2013-05-01

    Full Text Available In this paper, a human electrocardiogram (ECG identification system based on ensemble empirical mode decomposition (EEMD is designed. A robust preprocessing method comprising noise elimination, heartbeat normalization and quality measurement is proposed to eliminate the effects of noise and heart rate variability. The system is independent of the heart rate. The ECG signal is decomposed into a number of intrinsic mode functions (IMFs and Welch spectral analysis is used to extract the significant heartbeat signal features. Principal component analysis is used reduce the dimensionality of the feature space, and the K-nearest neighbors (K-NN method is applied as the classifier tool. The proposed human ECG identification system was tested on standard MIT-BIH ECG databases: the ST change database, the long-term ST database, and the PTB database. The system achieved an identification accuracy of 95% for 90 subjects, demonstrating the effectiveness of the proposed method in terms of accuracy and robustness.

  16. Design of wavelet-based ECG detector for implantable cardiac pacemakers.

    Science.gov (United States)

    Min, Young-Jae; Kim, Hoon-Ki; Kang, Yu-Ri; Kim, Gil-Su; Park, Jongsun; Kim, Soo-Won

    2013-08-01

    A wavelet Electrocardiogram (ECG) detector for low-power implantable cardiac pacemakers is presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. In order to achieve high detection accuracy with low power consumption, a multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited in our ECG detector implementation. Our algorithmic and architectural level approaches have been implemented and fabricated in a standard 0.35 μm CMOS technology. The testchip including a low-power analog-to-digital converter (ADC) shows a low detection error-rate of 0.196% and low power consumption of 19.02 μW with a 3 V supply voltage.

  17. Periodic Noise Suppression from ECG Signal using Novel Adaptive Filtering Techniques

    Directory of Open Access Journals (Sweden)

    Yogesh Sharma

    2012-03-01

    Full Text Available Electrocardiogram signal most commonly known recognized and used biomedical signal for medical examination of heart. The ECG signal is very sensitive in nature, and even if small noise mixed with original signal, the various characteristics of the signal changes, Data corrupted with noise must either filtered or discarded, filtering is important issue for design consideration of real time heart monitoring systems. Various filters used for removing the noise from ECG signals, most commonly used filters are Notch Filters, FIR filters, IIR filters, Wiener filter, Adaptive filters etc. Performance analysis shows that the best result is obtained by using Adaptive filter to remove various noises from ECG signal and get significant SNR andMSE results. In this paper a novel adaptive approach by using LMS algorithm and delay has shown whichcan be used for pre-processing of ECG signal and give appreciable result.

  18. An ECG Compressed Sensing Method of Low Power Body Area Network

    Directory of Open Access Journals (Sweden)

    Jizhong Liu

    2013-07-01

    Full Text Available Aimed at low power problem in body area network, an ECG compressed sensing method of low power body area network based on the compressed sensing theory was proposed. Random binary matrices were used as the sensing matrix to measure ECG signals on the sensor nodes. After measured value is transmitted to remote monitoring center, ECG signal sparse representation under the discrete cosine transform and block sparse Bayesian learning reconstruction algorithm is used to reconstruct the ECG signals. The simulation results show that the 30% of overall signal can get reconstruction signal which’s SNR is more than 60dB, each numbers in each rank of sensing matrix can be controlled below 5, which reduces the power of sensor node sampling, calculation and transmission. The method has the advantages of low power, high accuracy of signal reconstruction and easy to hardware implementation.  

  19. Quantification of Intracranial Aneurysm Morphodynamics from ECG-gated CT Angiography

    NARCIS (Netherlands)

    Firouzian, A.; Manniesing, R.; Metz, C.T.; Risselada, R.; Klein, S.; Kooten, F. van; Sturkenboom, M.C.; Lugt, A. van der; Niessen, W.J.

    2013-01-01

    Rationale and Objectives: Aneurysm morphodynamics is potentially relevant for assessing aneurysm rupture risk. A method is proposed for automated quantification and visualization of intracranial aneurysm morphodynamics from ECG-gated computed tomography angiography (CTA) data. Materials and Methods:

  20. Check your biosignals here: a new dataset for off-the-person ECG biometrics.

    Science.gov (United States)

    da Silva, Hugo Plácido; Lourenço, André; Fred, Ana; Raposo, Nuno; Aires-de-Sousa, Marta

    2014-02-01

    The Check Your Biosignals Here initiative (CYBHi) was developed as a way of creating a dataset and consistently repeatable acquisition framework, to further extend research in electrocardiographic (ECG) biometrics. In particular, our work targets the novel trend towards off-the-person data acquisition, which opens a broad new set of challenges and opportunities both for research and industry. While datasets with ECG signals collected using medical grade equipment at the chest can be easily found, for off-the-person ECG data the solution is generally for each team to collect their own corpus at considerable expense of resources. In this paper we describe the context, experimental considerations, methods, and preliminary findings of two public datasets created by our team, one for short-term and another for long-term assessment, with ECG data collected at the hand palms and fingers.

  1. REMOVAL OF 50HZ POWERLINE INTERFERENCE FOR QUALITY DIAGNOSIS OF ECG SIGNAL

    Directory of Open Access Journals (Sweden)

    SIGMA BARICK

    2013-05-01

    Full Text Available The power line interference (50/60 Hz is the main source of noise in most of bio-electric signal. In this paper second order infinite impulse response (IIR notch filter, adaptive notch filtering technique with LMS (least mean square algorithm and Discrete Wavelet transform method has been proposed for the removal of power line interference from ECG signal. Different ECG signals from MIT/BIH arrhythmia database are used with added power-line interference noise which is common in ECG signal. The result is analyzed using MATLABsoftware. Basically two synthesis parameters MSE and SNR have been used. The prime aim of this paper is to adapt the discrete wavelet transform (DWT to improve the ECG signal quality for better clinical diagnosis. The proposed method shows improvement in output SNR is 97.60%.

  2. Performance analysis of adjustable window based FIR filter for noisy ECG Signal Filtering

    Directory of Open Access Journals (Sweden)

    N. Mahawar

    2013-09-01

    Full Text Available Recording of the electrical activity associated to heart functioning is known as Electrocardiogram (ECG. ECG is a quasi-periodical, rhythmically signal synchronized by the function of the heart, which acts as a generator of bioelectric events. ECG signals are low level signals and sensitive to external contaminations. Electrocardiogram signals are often corrupted by noise which may have electrical or electrophysiological origin. The noise signal tends to alter the signal morphology, thereby hindering the correct diagnosis. In order to remove the unwanted noise, a digital filtering technique based on adjustable windows is proposed in this paper. Finite Impulse Response (FIR low pass is designed using windowing method for the ECG signal. The results obtained from different techniques are compared on the basis of popularly used signal error measures like SNR, PRD, PRD1, and MSE.

  3. Compression and Encryption of ECG Signal Using Wavelet and Chaotically Huffman Code in Telemedicine Application.

    Science.gov (United States)

    Raeiatibanadkooki, Mahsa; Quchani, Saeed Rahati; KhalilZade, MohammadMahdi; Bahaadinbeigy, Kambiz

    2016-03-01

    In mobile health care monitoring, compression is an essential tool for solving storage and transmission problems. The important issue is able to recover the original signal from the compressed signal. The main purpose of this paper is compressing the ECG signal with no loss of essential data and also encrypting the signal to keep it confidential from everyone, except for physicians. In this paper, mobile processors are used and there is no need for any computers to serve this purpose. After initial preprocessing such as removal of the baseline noise, Gaussian noise, peak detection and determination of heart rate, the ECG signal is compressed. In compression stage, after 3 steps of wavelet transform (db04), thresholding techniques are used. Then, Huffman coding with chaos for compression and encryption of the ECG signal are used. The compression rates of proposed algorithm is 97.72 %. Then, the ECG signals are sent to a telemedicine center to acquire specialist diagnosis by TCP/IP protocol.

  4. CinC Challenge 2013: comparing three algorithms to extract fetal ECG

    Science.gov (United States)

    Loja, Juan; Velecela, Esteban; Palacio-Baus, Kenneth; Astudillo, Darwin; Medina, Rubén.; Wong, Sara

    2015-12-01

    This paper reports a comparison between three fetal ECG (fECG) detectors developed during the CinC 2013 challenge for fECG detection. Algorithm A1 is based on Independent Component Analysis, A2 is based on fECG detection of RS Slope and A3 is based on Expectation-Weighted Estimation of Fiducial Points. The proposed methodology was validated using the annotated database available for the challenge. Each detector was characterized in terms of its performance by using measures of sensitivity, (Se), positive predictive value (P+) and delay time (td). Additionally, the database was contaminated with white noise for two SNR conditions. Decision fusion was tested considering the most common types of combination of detectors. Results show that the decision fusion of A1 and A2 improves fQRS detection, maintaining high Se and P+ even under low SNR conditions without a significant td increase.

  5. ECG Based Heart Arrhythmia Detection Using Wavelet Coherence and Bat Algorithm

    Science.gov (United States)

    Kora, Padmavathi; Sri Rama Krishna, K.

    2016-12-01

    Atrial fibrillation (AF) is a type of heart abnormality, during the AF electrical discharges in the atrium are rapid, results in abnormal heart beat. The morphology of ECG changes due to the abnormalities in the heart. This paper consists of three major steps for the detection of heart diseases: signal pre-processing, feature extraction and classification. Feature extraction is the key process in detecting the heart abnormality. Most of the ECG detection systems depend on the time domain features for cardiac signal classification. In this paper we proposed a wavelet coherence (WTC) technique for ECG signal analysis. The WTC calculates the similarity between two waveforms in frequency domain. Parameters extracted from WTC function is used as the features of the ECG signal. These features are optimized using Bat algorithm. The Levenberg Marquardt neural network classifier is used to classify the optimized features. The performance of the classifier can be improved with the optimized features.

  6. Are ECG monitoring recommendations before prescription of QT-prolonging drugs applied in daily practice?

    DEFF Research Database (Denmark)

    Warnier, Miriam Jacoba; Rutten, Frans Hendrik; Souverein, Patrick Cyriel

    2015-01-01

    PURPOSE: Monitoring of the QT duration by electrocardiography (ECG) prior to treatment is frequently recommended in the label of QT-prolonging drugs. It is, however, unknown how often general practitioners in daily clinical practice are adhering to these risk-minimization measures. We assessed...... the frequency of ECG measurements in patients where haloperidol was initiated in primary care. METHODS: Patients (≥18 years) with a first prescription of haloperidol in the UK Clinical Practice Research Datalink (2009-2013) were included. The proportion of ECGs made was determined in two blocks of 4 weeks......: during the exposure period when haloperidol was initiated, and during the control period, 1 year before. Conditional logistic regression analysis was applied to calculate the relative risk of having an ECG in the exposure period compared with the control period. Subgroup analyses were performed to assess...

  7. [Study on mobile phone based wireless ECG monitoring technology system typical demonstration applications].

    Science.gov (United States)

    Yu, Yang; Liu, Jing

    2011-01-01

    Based on the mobile phone platform with wireless real-time ECG monitoring system developed in our lab, this article is dedicated to evaluate its practical value in people test. A series of new conceptual experiments were designed and performed. Particularly, ECG characteristics under different age, gender, health and motion conditions are evaluated. Effects of living habits such as drinking wine, coffee including various psychological conditions such as excitation, anxiety etc. to the ECG response are investigated. The human ECG under different time in a day such as morning, afternoon and late-night was evaluated. These conceptual experiments, which are hard to conduct otherwise using conventional devices, demonstrate the pervasive merits of the new system for fundamental study of heart disease as well as daily healthcare.

  8. Left ventricular hypertrophy by ECG versus cardiac MRI as a predictor for heart failure.

    Science.gov (United States)

    Oseni, Abdullahi O; Qureshi, Waqas T; Almahmoud, Mohamed F; Bertoni, Alain G; Bluemke, David A; Hundley, William G; Lima, Joao A C; Herrington, David M; Soliman, Elsayed Z

    2017-01-01

    To determine if there is a significant difference in the predictive abilities of left ventricular hypertrophy (LVH) detected by ECG-LVH versus LVH ascertained by cardiac MRI-LVH in a model similar to the Framingham Heart Failure Risk Score (FHFRS). This study included 4745 (mean age 61±10 years, 53.5% women, 61.7% non-whites) participants in the Multi-Ethnic Study of Atherosclerosis. ECG-LVH was defined using Cornell voltage product while MRI-LVH was derived from left ventricular mass. Cox proportional hazard regression was used to examine the association between ECG-LVH and MRI-LVH with incident heart failure (HF). Harrell's concordance C-index was used to estimate the predictive ability of the model when either ECG-LVH or MRI-LVH was included as one of its components. ECG-LVH was present in 291 (6.1%), while MRI-LVH was present in 499 (10.5%) of the participants. Both ECG-LVH (HR 2.25, 95% CI 1.38 to 3.69) and MRI-LVH (HR 3.80, 95% CI 1.56 to 5.63) were predictive of HF. The absolute risk of developing HF was 8.81% for MRI-LVH versus 2.26% for absence of MRI-LVH with a relative risk of 3.9. With ECG-LVH, the absolute risk of developing HF 6.87% compared with 2.69% for absence of ECG-LVH with a relative risk of 2.55. The ability of the model to predict HF was better with MRI-LVH (C-index 0.871, 95% CI 0.842 to 0.899) than with ECG-LVH (C-index 0.860, 95% CI 0.833 to 0.888) (p<0.0001). ECG-LVH and MRI-LVH are predictive of HF. Substituting MRI-LVH for ECG-LVH improves the predictive ability of a model similar to the FHFRS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Note: electrode polarization of Galinstan electrodes for liquid impedance spectroscopy.

    Science.gov (United States)

    Mellor, Brett L; Kellis, Nathan A; Mazzeo, Brian A

    2011-04-01

    Electrode polarization is a significant obstacle in the impedance measurements of ionic liquids. An atomically smooth electrode surface could potentially reduce unwanted impedance contributions from electrode polarization. Liquid metal electrodes were formed by adhering Galinstan to acrylic plates in a parallel-plate capacitor arrangement. Electrode polarization was compared to a similar cell with stainless steel electrodes. The impedance of salt and protein solutions (β-lactoglobulin) was measured from 40 Hz to 110 MHz. Because of oxide layer formation, the performance of the Galinstan electrode is significantly different than the theoretical ideal.

  10. Preparation of Electrode Array by Electrochemical Etching Based on FEM

    Institute of Scientific and Technical Information of China (English)

    Minghuan WANG; Di ZHU; Lei WANG

    2008-01-01

    Process technology of multiple cylindrical micro-pins by wire-electrical discharge machining (wire-EDM) and electrochemical etching was presented.A row of rectangular micro-columns were machined by wire-EDM and then machined into cylindrical shape by electrochemical etching.However,the shape of the multiple electrodes and the consistent sizes of the electrodes row are not easy to be controlled.In the electrochemical process,the shape of the cathode electrode determines the current density distribution on the anode and so the forming of multiple electrodes.This paper proposes a finite element method (FEM) to accurately optimize the electrode profile.The microelectrodes row with uniformity diameters with size from hundreds micrometers to several decades could be fabricated,and mathematical model controlling the shape and diameter of multiple microelectrodes was provided.Furthermore,a good agreement between experimental and theoretical results was confirmed.

  11. ECG response of koalas to tourists proximity: a preliminary study.

    Directory of Open Access Journals (Sweden)

    Yan Ropert-Coudert

    Full Text Available Koalas operate on a tight energy budget and, thus, may not always display behavioral avoidance reaction when placed in a stressful condition. We investigated the physiological response of captive koalas Phascolarctos cinereus in a conservation centre to the presence of tourists walking through their habitat. We compared, using animal-attached data-recorders, the electrocardiogram activity of female koalas in contact with tourists and in a human-free area. One of the koalas in the tourist zone presented elevated heart rate values and variability throughout the recording period. The remaining female in the exhibit area showed a higher field resting heart rates during the daytime than that in the isolated area. In the evening, heart rate profiles changed drastically and both the koalas in the exhibit and in the tourist-free zones displayed similar field resting heart rates, which were lower than those during the day. In parallel, the autonomic nervous systems of these two individuals evolved from sympathetic-dominant during the day to parasympathetic-dominant in the evening. Our results report ECG of free-living koalas for the first time. Although they are preliminary due to the difficulty of having sufficient samples of animals of the same sex and age, our results stress out the importance of studies investigating the physiological reaction of animals to tourists.

  12. Efficient noise cancellers for ECG signal enhancement for telecardiology applications

    Directory of Open Access Journals (Sweden)

    Nagesh MANTRAVADI

    2016-12-01

    Full Text Available In this paper some effective noise cancellers were proposed using the variants of Least Mean Fourth (LMF Algorithm to remove the artifacts that occur during the acquisition stage of an ECG signal. In order to accelerate the performance of the LMF algorithm we introduce data normalization in weight update process. This results two variants of LMF algorithm, called normalized LMF (NLMF and global NLMF (GNLMF algorithms. Further, to minimize their computational complexity and improve convergence characteristics, tracking ability, filtering capability we apply signum and block processing on the two versions of normalized algorithms. Both the two treatments results six more algorithms. Using these algorithms we develop various adaptive noise cancellers (ANCs. These ANCs are tested with the help of standard MIT-BIH arrhythmia database for various records. The Signal to noise ratio, Excess Mean Square Error and misadjustment are taken as performances measures to analyze the performance of proposed methods. These ANCs exhibit improved performance over the LMF based ANC.

  13. ECG response of koalas to tourists proximity: a preliminary study.

    Science.gov (United States)

    Ropert-Coudert, Yan; Brooks, Lisa; Yamamoto, Maki; Kato, Akiko

    2009-10-12

    Koalas operate on a tight energy budget and, thus, may not always display behavioral avoidance reaction when placed in a stressful condition. We investigated the physiological response of captive koalas Phascolarctos cinereus in a conservation centre to the presence of tourists walking through their habitat. We compared, using animal-attached data-recorders, the electrocardiogram activity of female koalas in contact with tourists and in a human-free area. One of the koalas in the tourist zone presented elevated heart rate values and variability throughout the recording period. The remaining female in the exhibit area showed a higher field resting heart rates during the daytime than that in the isolated area. In the evening, heart rate profiles changed drastically and both the koalas in the exhibit and in the tourist-free zones displayed similar field resting heart rates, which were lower than those during the day. In parallel, the autonomic nervous systems of these two individuals evolved from sympathetic-dominant during the day to parasympathetic-dominant in the evening. Our results report ECG of free-living koalas for the first time. Although they are preliminary due to the difficulty of having sufficient samples of animals of the same sex and age, our results stress out the importance of studies investigating the physiological reaction of animals to tourists.

  14. Human ECG indicators for fast screening and evaluation

    Science.gov (United States)

    Maciejewski, Marcin; DzierŻak, RóŻa; Surtel, Wojciech; Saran, Tomasz

    2016-09-01

    Telemedical system design and implementation requires numerous steps. It is necessary to evaluate the operation of algorithms responsible for analysis and detection of life-threatening situations. By performing ECG analysis it is possible to obtain information about the overall patient health condition as well as detailed information about the circulatory system condition. To achieve that goal one must gather, filter and process data. Data was gathered using a purposely built device from a group of four volunteers. Available data set was processed to obtain information about the patients condition. Pan-Tompkins algorithm was used to detect R peaks and calculate heart rhythm. Afterward the rest of parameters were extracted in time domain using windowed peak detection and polynomial estimation. The parameters were calculated as delays between appropriate points in the signal. The method proved to be able to extract parameters in some of the cases, and proved limited effectiveness in situations where physical activity was significant. It was nevertheless possible to eliminate noise from the mains, the trend and higher frequency noise Further improvements need to be introduced to increase the method's robustness in the presence of significant muscle noise.

  15. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    OpenAIRE

    Penzel, Thomas; Kantelhardt, Jan W.; Bartsch, Ronny P.; Riedl, Maik; Kraemer, Jan F.; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents ph...

  16. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    OpenAIRE

    Thomas Penzel; Kantelhardt, Jan W.; Bartsch, Ronny P.; Maik Riedl; Jan Krämer; Niels Wessel; Carmen Garcia; Martin Glos; Ingo Fietze; Christoph Schöbel

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical) sequence. It presents phys...

  17. Agreement between a smart-phone pulse sensor application and ECG for determining lnRMSSD.

    Science.gov (United States)

    Esco, Michael R; Flatt, Andrew A; Nakamura, Fabio Y

    2016-06-27

    The purpose of this study was to determine the agreement between a smartphone pulse finger sensor (SPFS) and electrocardiography (ECG) for determining ultra-short-term heart rate variability (HRV) in three different positions. Thirty college-aged men (n = 15) and women (n = 15) volunteered to participate in this study. Sixty second heart rate measures were simultaneously taken with the SPFS and ECG in supine, seated and standing positions. lnRMSSD was calculated from the SPFS and ECG. The lnRMSSD values were 81.5 ± 11.7 via ECG and 81.6 ± 11.3 via SPFS (p = 0.63, Cohen's d = 0.01) in the supine position, 76.5 ± 8.2 via ECG and 77.5 ± 8.2 via SPFS (p = 0.007, Cohen's d = 0.11) in the seated position, and 66.5 ± 9.2 via ECG and 67.8 ± 9.1 via SPFS (p < 0.001, Cohen's d = 0.15) in the standing positions. The SPFS showed a possibly strong correlation to the ECG in all three positions (r values from 0.98 to 0.99). In addition, the limits of agreement (CE ± 1.98 SD) were -0.13 ± 2.83 for the supine values, -0.94± 3.47 for the seated values, and -1.37 ± 3.56 for the standing values. The results of the study suggest good agreement between the SPFS and ECG for measuring lnRMSSD in supine, seated, and standing positions. Though significant differences were noted between the two methods in the seated and standing positions, the effect sizes were trivial.

  18. Removal of Baseline Wander Noise from Electrocardiogram (ECG) using Fifth-order Spline Interpolation

    OpenAIRE

    John A. OJO; Temilade B. ADETOYI; Solomon A. Adeniran

    2016-01-01

    Baseline wandering can mask some important features of the Electrocardiogram (ECG) signal hence it is desirable to remove this noise for proper analysis and display of the ECG signal. This paper presents the implementation and evaluation of spline interpolation and linear phase FIR filtering methods to remove this noise. Spline interpolation method requires the QRS waves to be first detected and fifth-order (quintic) interpolation technique applied to determine the smo...

  19. A wavelet-based ECG delineation algorithm for 32-bit integer online processing

    OpenAIRE

    Chiari Lorenzo; Di Marco Luigi Y

    2011-01-01

    Abstract Background Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave, QRS, and mono- or bi-phasic T wave) would make it a suitable candidate for efficient online processing of ambulatory ECG signals. Unfortunately, previous implementati...

  20. Motion artifact removal algorithm by ICA for e-bra: a women ECG measurement system

    Science.gov (United States)

    Kwon, Hyeokjun; Oh, Sechang; Varadan, Vijay K.

    2013-04-01

    Wearable ECG(ElectroCardioGram) measurement systems have increasingly been developing for people who suffer from CVD(CardioVascular Disease) and have very active lifestyles. Especially, in the case of female CVD patients, several abnormal CVD symptoms are accompanied with CVDs. Therefore, monitoring women's ECG signal is a significant diagnostic method to prevent from sudden heart attack. The E-bra ECG measurement system from our previous work provides more convenient option for women than Holter monitor system. The e-bra system was developed with a motion artifact removal algorithm by using an adaptive filter with LMS(least mean square) and a wandering noise baseline detection algorithm. In this paper, ICA(independent component analysis) algorithms are suggested to remove motion artifact factor for the e-bra system. Firstly, the ICA algorithms are developed with two kinds of statistical theories: Kurtosis, Endropy and evaluated by performing simulations with a ECG signal created by sgolayfilt function of MATLAB, a noise signal including 0.4Hz, 1.1Hz and 1.9Hz, and a weighed vector W estimated by kurtosis or entropy. A correlation value is shown as the degree of similarity between the created ECG signal and the estimated new ECG signal. In the real time E-Bra system, two pseudo signals are extracted by multiplying with a random weighted vector W, the measured ECG signal from E-bra system, and the noise component signal by noise extraction algorithm from our previous work. The suggested ICA algorithm basing on kurtosis or entropy is used to estimate the new ECG signal Y without noise component.

  1. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    Science.gov (United States)

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support

  2. Exploring Neuro-Physiological Correlates of Drivers' Mental Fatigue Caused by Sleep Deprivation Using Simultaneous EEG, ECG, and fNIRS Data

    Science.gov (United States)

    Ahn, Sangtae; Nguyen, Thien; Jang, Hyojung; Kim, Jae G.; Jun, Sung C.

    2016-01-01

    Investigations of the neuro-physiological correlates of mental loads, or states, have attracted significant attention recently, as it is particularly important to evaluate mental fatigue in drivers operating a motor vehicle. In this research, we collected multimodal EEG/ECG/EOG and fNIRS data simultaneously to develop algorithms to explore neuro-physiological correlates of drivers' mental states. Each subject performed simulated driving under two different conditions (well-rested and sleep-deprived) on different days. During the experiment, we used 68 electrodes for EEG/ECG/EOG and 8 channels for fNIRS recordings. We extracted the prominent features of each modality to distinguish between the well-rested and sleep-deprived conditions, and all multimodal features, except EOG, were combined to quantify mental fatigue during driving. Finally, a novel driving condition level (DCL) was proposed that distinguished clearly between the features of well-rested and sleep-deprived conditions. This proposed DCL measure may be applicable to real-time monitoring of the mental states of vehicle drivers. Further, the combination of methods based on each classifier yielded substantial improvements in the classification accuracy between these two conditions. PMID:27242483

  3. Porous Electrode Studies.

    Science.gov (United States)

    1980-07-01

    representation and analysis for their observed current distributions. Simonsson won the young author’s award of the Electrochemical Society for his paper...and T. Katan, Proc. Symp. Energy Storage and Conversion, the Electrochemical Society 77-6, 770 (1977) The optimum thickness of porous electrodes is...Chloride Electrodes; Surface Morphology on Charging and Dis- charging," T. Katan, S. Szpak, and D. N. Bennion, The Electrochemical Society , 143rd National

  4. Techniques of Electrode Fabrication

    Science.gov (United States)

    Guo, Liang; Li, Xinyong; Chen, Guohua

    Electrochemical applications using many kinds of electrode materials as an advanced oxidation/reduction technique have been a focus of research by a number of groups during the last two decades. The electrochemical approach has been adopted successfully to develop various environmental applications, mainly including water and wastewater treatment, aqueous system monitoring, and solid surface analysis. In this chapter, a number of methods for the fabrication of film-structured electrode materials were selectively reviewed. Firstly, the thermal decomposition method is briefly described, followed by introducing chemical vapor deposition (CVD) strategy. Especially, much attention was focused on introducing the methods to produce diamond novel film electrode owing to its unique physical and chemical properties. The principle and influence factors of hot filament CVD and plasma enhanced CVD preparation were interpreted by refereeing recent reports. Finally, recent developments that address electro-oxidation/reduction issues and novel electrodes such as nano-electrode and boron-doped diamond electrode (BDD) are presented in the overview.

  5. Application of Handheld Tele-ECG for Health Care Delivery in Rural India

    Directory of Open Access Journals (Sweden)

    Meenu Singh

    2014-01-01

    Full Text Available Telemonitoring is a medical practice that involves remotely monitoring patients who are not at the same location as the health care provider. The purpose of our study was to use handheld tele-electrocardiogram (ECG developed by Bhabha Atomic Research Center (BARC to identify heart conditions in the rural underserved population where the doctor-patient ratio is low and access to health care is difficult. The objective of our study was clinical validation of handheld tele-ECG as a screening tool for evaluation of cardiac diseases in the rural population. ECG was obtained in 450 individuals (mean age 31.49 ± 20.058 residing in the periphery of Chandigarh, India, from April 2011 to March 2013, using the handheld tele-ECG machine. The data were then transmitted to physicians in Postgraduate Institute of Medical Education and Research (PGIMER, Chandigarh, for their expert opinion. ECG was interpreted as normal in 70% individuals. Left ventricular hypertrophy (9.3% was the commonest abnormality followed closely by old myocardial infarction (5.3%. Patient satisfaction was reported to be ~95%. Thus, it can be safely concluded that tele-ECG is a portable, cost-effective, and convenient tool for diagnosis and monitoring of heart diseases and thus improves quality and accessibility, especially in rural areas.

  6. Wavelet-Based ECG Steganography for Protecting Patient Confidential Information in Point-of-Care Systems.

    Science.gov (United States)

    Ibaida, Ayman; Khalil, Ibrahim

    2013-12-01

    With the growing number of aging population and a significant portion of that suffering from cardiac diseases, it is conceivable that remote ECG patient monitoring systems are expected to be widely used as point-of-care (PoC) applications in hospitals around the world. Therefore, huge amount of ECG signal collected by body sensor networks from remote patients at homes will be transmitted along with other physiological readings such as blood pressure, temperature, glucose level, etc., and diagnosed by those remote patient monitoring systems. It is utterly important that patient confidentiality is protected while data are being transmitted over the public network as well as when they are stored in hospital servers used by remote monitoring systems. In this paper, a wavelet-based steganography technique has been introduced which combines encryption and scrambling technique to protect patient confidential data. The proposed method allows ECG signal to hide its corresponding patient confidential data and other physiological information thus guaranteeing the integration between ECG and the rest. To evaluate the effectiveness of the proposed technique on the ECG signal, two distortion measurement metrics have been used: the percentage residual difference and the wavelet weighted PRD. It is found that the proposed technique provides high-security protection for patients data with low (less than 1%) distortion and ECG data remain diagnosable after watermarking (i.e., hiding patient confidential data) and as well as after watermarks (i.e., hidden data) are removed from the watermarked data.

  7. Low-cost compact ECG with graphic LCD and phonocardiogram system design.

    Science.gov (United States)

    Kara, Sadik; Kemaloğlu, Semra; Kirbaş, Samil

    2006-06-01

    Till today, many different ECG devices are made in developing countries. In this study, low cost, small size, portable LCD screen ECG device, and phonocardiograph were designed. With designed system, heart sounds that take synchronously with ECG signal are heard as sensitive. Improved system consist three units; Unit 1, ECG circuit, filter and amplifier structure. Unit 2, heart sound acquisition circuit. Unit 3, microcontroller, graphic LCD and ECG signal sending unit to computer. Our system can be used easily in different departments of the hospital, health institution and clinics, village clinic and also in houses because of its small size structure and other benefits. In this way, it is possible that to see ECG signal and hear heart sounds as synchronously and sensitively. In conclusion, heart sounds are heard on the part of both doctor and patient because sounds are given to environment with a tiny speaker. Thus, the patient knows and hears heart sounds him/herself and is acquainted by doctor about healthy condition.

  8. Treatment of anestrous Nili-Ravi buffaloes using eCG and CIDR protocols

    Institute of Scientific and Technical Information of China (English)

    Zahid Naseer; Ejaz Ahmad; Nemat Ullah; Muhammad Yaqoob; Zeeshan Akbar

    2013-01-01

    Objective: To determine the effect of equine chorionic gonadotropin (eCG) and controlled internal drug releasing (CIDR) on estrus response, ovulation and pregnancy rate in Nili-Ravi buffaloes under field condition. Methods: Twenty anestrous buffaloes with more than 150 days postpartum were used in this study. To confirm anestrous condition, ovarian status and serum progesterone concentration were determined before the start of study. Buffaloes were randomly divided into eCG (n=10) and CIDR (n=10) groups. eCG group were treated with eCG (Chronogest 1000 I.U. i.m.), while CIDR group received CIDR devices for 7 days. All buffaloes in CIDR group were injected PGF2α (0.25 ug/mL; 2 mL; i.m.) one day before CIDR removal. Buffaloes were observed for estrus visually and were inseminated with frozen-thawed semen at detected estrus. Ovulation was confirmed by presence of CL 12 day post AI. Pregnancy diagnosis was done 50 days post AI. Results: Estrus response, ovulation rate and pregnancy rate were similar (P>0.05) among eCG and CIDR groups (90% vs. 80%; 78% vs. 75% and 50% vs. 60% respectively). Conclusion: It is concluded that both CIDR and eCG protocols are effective and promising remedies for the anestrous buffaloes under commercial as well as under field conditions.

  9. An estimate of the dispersion of repolarization times based on a biophysical model of the ECG.

    Science.gov (United States)

    Sassi, Roberto; Mainardi, Luca T

    2011-12-01

    Temporal heterogeneity of ventricular repolarization is a key quantity for the development of ventricular reentrant arrhythmia. In this paper, we introduce the V-index, a novel ECG-based estimator of the standard deviation of ventricular myocytes' repolarization times s(ϑ). Differently from other ECG metrics of repolarization heterogeneity, the V-index was derived from the analysis of a biophysical model of the ECG, where repolarization is described by the dominant T-wave (DTW) paradigm. The model explains the shape of T-waves in each lead as a projection of a main waveform (the DTW) and its derivatives weighted by scalars, the lead factors. A mathematical formula is derived to link the heterogeneity of ventricular repolarization s(ϑ) and the V-index. The formula was verified using synthetic 12-lead ECGs generated with a direct electrophysiological model for increasing values of s(ϑ) (in the range 20-70 ms). A linear relationship between the V-index and s(ϑ) was observed, V ≈ 0.675 s(ϑ) + 1.8 ms (R(2) = 0.9992). Finally, 68 ECGs from the E-OTH-12-0068-010 database of the Telemetric and Holter ECG Warehouse were analyzed. The V-index coherently increased after sotalol administration, a drug known to have QT-prolonging potential (p < 0.001).

  10. An efficient unsupervised fetal QRS complex detection from abdominal maternal ECG.

    Science.gov (United States)

    Varanini, M; Tartarisco, G; Billeci, L; Macerata, A; Pioggia, G; Balocchi, R

    2014-08-01

    Non-invasive fetal heart rate is of great relevance in clinical practice to monitor fetal health state during pregnancy. To date, however, despite significant advances in the field of electrocardiography, the analysis of abdominal fetal ECG is considered a challenging problem for biomedical and signal processing communities. This is mainly due to the low signal-to-noise ratio of fetal ECG and difficulties in cancellation of maternal QRS complexes, motion and electromyographic artefacts. In this paper we present an efficient unsupervised algorithm for fetal QRS complex detection from abdominal multichannel signal recordings combining ICA and maternal ECG cancelling, which outperforms each single method. The signal is first pre-processed to remove impulsive artefacts, baseline wandering and power line interference. The following steps are then applied: maternal ECG extraction through independent component analysis (ICA); maternal QRS detection; maternal ECG cancelling through weighted singular value decomposition; enhancing of fetal ECG through ICA and fetal QRS detection. We participated in the Physionet/Computing in Cardiology Challenge 2013, obtaining the top official scores of the challenge (among 53 teams of participants) of event 1 and event 2 concerning fetal heart rate and fetal interbeat intervals estimation section. The developed algorithms are released as open-source on the Physionet website.

  11. Self-organized neural network for the quality control of 12-lead ECG signals.

    Science.gov (United States)

    Chen, Yun; Yang, Hui

    2012-09-01

    Telemedicine is very important for the timely delivery of health care to cardiovascular patients, especially those who live in the rural areas of developing countries. However, there are a number of uncertainty factors inherent to the mobile-phone-based recording of electrocardiogram (ECG) signals such as personnel with minimal training and other extraneous noises. PhysioNet organized a challenge in 2011 to develop efficient algorithms that can assess the ECG signal quality in telemedicine settings. This paper presents our efforts in this challenge to integrate multiscale recurrence analysis with a self-organizing map for controlling the ECG signal quality. As opposed to directly evaluating the 12-lead ECG, we utilize an information-preserving transform, i.e. Dower transform, to derive the 3-lead vectorcardiogram (VCG) from the 12-lead ECG in the first place. Secondly, we delineate the nonlinear and nonstationary characteristics underlying the 3-lead VCG signals into multiple time-frequency scales. Furthermore, a self-organizing map is trained, in both supervised and unsupervised ways, to identify the correlations between signal quality and multiscale recurrence features. The efficacy and robustness of this approach are validated using real-world ECG recordings available from PhysioNet. The average performance was demonstrated to be 95.25% for the training dataset and 90.0% for the independent test dataset with unknown labels.

  12. Real-time CHF detection from ECG signals using a novel discretization method.

    Science.gov (United States)

    Orhan, Umut

    2013-10-01

    This study proposes a new method, equal frequency in amplitude and equal width in time (EFiA-EWiT) discretization, to discriminate between congestive heart failure (CHF) and normal sinus rhythm (NSR) patterns in ECG signals. The ECG unit pattern concept was introduced to represent the standard RR interval, and our method extracted certain features from the unit patterns to classify by a primitive classifier. The proposed method was tested on two classification experiments by using ECG records in Physiobank databases and the results were compared to those from several previous studies. In the first experiment, an off-line classification was performed with unit patterns selected from long ECG segments. The method was also used to detect CHF by real-time ECG waveform analysis. In addition to demonstrating the success of the proposed method, the results showed that some unit patterns in a long ECG segment from a heart patient were more suggestive of disease than the others. These results indicate that the proposed approach merits additional research.

  13. Genetic algorithm for the optimization of features and neural networks in ECG signals classification

    Science.gov (United States)

    Li, Hongqiang; Yuan, Danyang; Ma, Xiangdong; Cui, Dianyin; Cao, Lu

    2017-01-01

    Feature extraction and classification of electrocardiogram (ECG) signals are necessary for the automatic diagnosis of cardiac diseases. In this study, a novel method based on genetic algorithm-back propagation neural network (GA-BPNN) for classifying ECG signals with feature extraction using wavelet packet decomposition (WPD) is proposed. WPD combined with the statistical method is utilized to extract the effective features of ECG signals. The statistical features of the wavelet packet coefficients are calculated as the feature sets. GA is employed to decrease the dimensions of the feature sets and to optimize the weights and biases of the back propagation neural network (BPNN). Thereafter, the optimized BPNN classifier is applied to classify six types of ECG signals. In addition, an experimental platform is constructed for ECG signal acquisition to supply the ECG data for verifying the effectiveness of the proposed method. The GA-BPNN method with the MIT-BIH arrhythmia database achieved a dimension reduction of nearly 50% and produced good classification results with an accuracy of 97.78%. The experimental results based on the established acquisition platform indicated that the GA-BPNN method achieved a high classification accuracy of 99.33% and could be efficiently applied in the automatic identification of cardiac arrhythmias.

  14. Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model.

    Science.gov (United States)

    Mäntynen, Ville; Konttila, Teijo; Stenroos, Matti

    2014-12-07

    Solving the inverse problem of electrocardiography (ECG) and magnetocardiography (MCG) is often referred to as cardiac source imaging. Spatial properties of ECG and MCG as imaging systems are, however, not well known. In this modelling study, we investigate the sensitivity and point-spread function (PSF) of ECG, MCG, and combined ECG+MCG as a function of source position and orientation, globally around the ventricles: signal topographies are modelled using a realistically-shaped volume conductor model, and the inverse problem is solved using a distributed source model and linear source estimation with minimal use of prior information. The results show that the sensitivity depends not only on the modality but also on the location and orientation of the source and that the sensitivity distribution is clearly reflected in the PSF. MCG can better characterize tangential anterior sources (with respect to the heart surface), while ECG excels with normally-oriented and posterior sources. Compared to either modality used alone, the sensitivity of combined ECG+MCG is less dependent on source orientation per source location, leading to better source estimates. Thus, for maximal sensitivity and optimal source estimation, the electric and magnetic measurements should be combined.

  15. Artificial neural network-based classification of body movements in ambulatory ECG signal.

    Science.gov (United States)

    Darji, Sachin T; Kher, Rahul K

    2013-11-01

    Abstract Ambulatory ECG monitoring provides electrical activity of the heart when a person is involved in doing normal routine activities. Thus, the recorded ECG signal consists of cardiac signal along with motion artifacts introduced due to a person's body movements during routine activities. Detection of motion artifacts due to different physical activities might help in further cardiac diagnosis. Ambulatory ECG signal analysis for detection of various motion artifacts using adaptive filtering approach is addressed in this paper. We have used BIOPAC MP 36 system for acquiring ECG signal. The ECG signals of five healthy subjects (aged between 22-30 years) were recorded while the person performed various body movements like up and down movement of the left hand, up and down movement of the right hand, waist twisting movement while standing and change from sitting down on a chair to standing up movement in lead I configuration. An adaptive filter-based approach has been used to extract the motion artifact component from the ambulatory ECG signal. The features of motion artifact signal, extracted using Gabor transform, have been used to train the artificial neural network (ANN) for classifying body movements.

  16. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    Directory of Open Access Journals (Sweden)

    Thomas Penzel

    2016-10-01

    Full Text Available The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave.

  17. Sensor employing internal reference electrode

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same.......The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same....

  18. Variable selectivity of the Hitachi chemistry analyzer chloride ion-selective electrode toward interfering ions.

    Science.gov (United States)

    Wang, T; Diamandis, E P; Lane, A; Baines, A D

    1994-02-01

    Chloride measurements by ion-selective electrodes are vulnerable to interference by anions such as iodide, thiocyanate, nitrate, and bromide. We have found that the degree of interference of these anions on the Hitachi chemistry analyzer chloride electrode varies from electrode to electrode and this variation can even occur within the same lot of membrane. This variation is not dependent upon the length of time the cartridge has been in the analyzer because no correlation existed between the usage time and the electrode response to interfering ions. Neither is this variation due to the deterioration of the electrode because all electrodes tested had calibration slopes within the manufacturer's specification. Our study, however, showed that even after repeated exposure to a plasma sample containing 2 mM thiocyanate, the chloride electrode was still able to accurately measure the chloride in plasma without thiocyanate, thus confirming that a carryover effect does not exist from a previous thiocyanate-containing sample.

  19. Two Proximal Skin Electrodes — A Respiration Rate Body Sensor

    Directory of Open Access Journals (Sweden)

    Viktor Avbelj

    2012-10-01

    Full Text Available We propose a new body sensor for extracting the respiration rate based on the amplitude changes in the body surface potential differences between two proximal body electrodes. The sensor could be designed as a plaster-like reusable unit that can be easily fixed onto the surface of the body. It could be equipped either with a sufficiently large memory for storing the measured data or with a low-power radio system that can transmit the measured data to a gateway for further processing. We explore the influence of the sensor’s position on the quality of the extracted results using multi-channel ECG measurements and considering all the pairs of two neighboring electrodes as potential respiration-rate sensors. The analysis of the clinical measurements, which also include reference thermistor-based respiration signals, shows that the proposed approach is a viable option for monitoring the respiration frequency and for a rough classification of breathing types. The obtained results were evaluated on a wireless prototype of a respiration body sensor. We indicate the best positions for the respiration body sensor and prove that a single sensor for body surface potential difference on proximal skin electrodes can be used for combined measurements of respiratory and cardiac activities.

  20. NNLOPS accurate associated HW production

    CERN Document Server

    Astill, William; Re, Emanuele; Zanderighi, Giulia

    2016-01-01

    We present a next-to-next-to-leading order accurate description of associated HW production consistently matched to a parton shower. The method is based on reweighting events obtained with the HW plus one jet NLO accurate calculation implemented in POWHEG, extended with the MiNLO procedure, to reproduce NNLO accurate Born distributions. Since the Born kinematics is more complex than the cases treated before, we use a parametrization of the Collins-Soper angles to reduce the number of variables required for the reweighting. We present phenomenological results at 13 TeV, with cuts suggested by the Higgs Cross Section Working Group.