WorldWideScience

Sample records for dvi direct vessel

  1. Advanced DVI for ECC direct bypass mitigation

    International Nuclear Information System (INIS)

    Kwon, Tae-Soon; Song, Chul-Hwa; Baek, Won-Pil

    2009-01-01

    An ECC direct bypass fraction during a late reflood phase of a LBLOCA is strongly dependent on the characteristics of the cross flow and the geometrical configuration of a DVI in the downcomer of a pressurized light water reactor. The important design parameters of a DVI are the elevation, the azimuthal angle, and the separator to prevent a steam-water interaction. An ECC sub-channel to separate or to isolate an ECC water from a high-speed cross flow is one of the important design features to mitigate the ECC bypass phenomena. A dual core barrel cylinder as an ECC flow separator is located between a reactor vessel and a core barrel outer wall in the downcomer annulus. A new narrow gap between the core barrel and the additional dual core barrel plays the role of a downward ECC flow channel or an ECC flow separator in a high-speed cross flow field of the downcomer annulus. The flow zone around a broken cold leg in the downcomer annulus has the role of a high ECC direct bypass due to a strong suction force while the wake zone of a hot leg has the role of an ECC penetration. Thus, the relative azimuthal angle of the DVI nozzle from the broken cold leg is an important design parameter. A large azimuthal angle from a cold leg to a hot leg needs to avoid a high suction flow zone when an ECC water is being injected. The other enhancing mechanism of an ECC penetration is a grooved core barrel which has small rectangular-shaped grooves vertically arranged on the core barrel wall of the reactor vessel downcomer annulus. These grooves have the role for a generation of a vortex induced by a high-speed cross flow. Since the stagnant flow in a lateral direction and rotational vortex provides the pulling force of an ECC drop or film to flow down into the lower downcomer annulus by gravity, the ECC direct bypass fraction is reduced when compared to the current design of a smoothed wall. An open channel of grooves generates a stagnant vortex, while a closed channel of grooves

  2. Performance Analysis of AP1000 Passive Systems during Direct Vessel Injection (DVI Line Break

    Directory of Open Access Journals (Sweden)

    A.S. Ekariansyah

    2016-08-01

    Full Text Available Generation II Nuclear Power Plants (NPPs have a design weakness as shown by the Fukushima accident. Therefore, Generation III+ NPPs are developed with focus on improvements of fuel technology and thermal efficiency, standardized design, and the use of passive safety system. One type of Generation III+ NPP is the AP1000 that is a pressurized water reactor (PWR type that has received the final design acceptance from US-NRC and is already under construction at several sites in China as of 2015. The aim of this study is to investigate the behavior and performance of the passive safety system in the AP1000 and to verify the safety margin during the direct vessel injection (DVI line break as selected event. This event was simulated using RELAP5/SCDAP/Mod3.4 as a best-estimate code developed for transient simulation of light water reactors during postulated accidents. This event is also described in the AP1000 design control document as one of several postulated accidents simulated using the NOTRUMP code. The results obtained from RELAP5 calculation was then compared with the results of simulations using the NOTRUMP code. The results show relatively good agreements in terms of time sequences and characteristics of some injected flow from the passive safety system. The simulation results show that the break of one of the two available DVI lines can be mitigated by the injected coolant flowing, which is operated effectively by gravity and density difference in the cooling system and does not lead to core uncovery. Despite the substantial effort to obtain an apropriate AP1000 model due to lack of detailed geometrical data, the present model can be used as a platform model for other initiating event considered in the AP1000 accident analysis.

  3. SPACE code simulation of ATLAS DVI line break accident test (SB DVI 08 Test)

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Gyu [KHNP, Daejeon (Korea, Republic of)

    2012-10-15

    APR1400 has adopted new safety design features which are 4 mechanically independent DVI (Direct Vessel Injection) systems and fluidic device in the safety injection tanks (SITs). Hence, DVI line break accident has to be evaluated as one of the small break LOCA (SBLOCA) to ensure the safety of APR1400. KAERI has been performed for DVI line break test (SB DVI 08) using ATLAS (Advanced Thermal Hydraulic Test Loop for Accident Simulation) facility which is an integral effect test facility for APR1400. The test result shows that the core collapsed water level decreased before a loop seal clearance, so that a core uncover occurred. At this time, the peak cladding temperature (PCT) is rapidly increased even though the emergency core cooling (ECC) water is injected from safety injection pump (SIP). This test result is useful for supporting safety analysis using thermal hydraulic safety analysis code and increases the understanding of SBLOCA phenomena in APR1400. The SBLOCA evaluation methodology for APR1400 is now being developed using SPACE code. The object of the development of this methodology is to set up a conservative evaluation methodology in accordance with appendix K of 10 CFR 50. ATLAS SB DVI 08 test is selected for the evaluation of SBLOCA methodology using SPACE code. Before applying the conservative models and correlations, benchmark calculation of the test is performed with the best estimate models and correlations to verify SPACE code capability. This paper deals with benchmark calculations results of ATLAS SB DVI 08 test. Calculation results of the major hydraulics variables are compared with measured data. Finally, this paper carries out the SPACE code performances for simulating the integral effect test of SBLOCA.

  4. Small break loss of coolant accident analysis of advanced PWR plant designs utilizing DVI line venturis

    International Nuclear Information System (INIS)

    Kemper, Robert M.; Gagnon, Andre F.; McNamee, Kevin; Cheung, Augustine C.

    1995-01-01

    The Westinghouse Advanced Passive and evolutionary Pressurizer Water Reactors (i.e. AP600 and APWR) incorporate direct vessel injection (DVI) of emergency core coolant as a means of minimizing the potential spilling of emergency core cooling water during a loss of coolant accident (LOCA). As a result, the most limiting small break LOCA (SBLOCA) event for these designs, with respect core inventory makeup capability, is a postulated double ended rupture of one of the DVI lines. This paper presents the results of a design optimization study that examines the installation of a venturi in the DVI line as a means of limiting the reactor coolant lost from the reactor vessel. The comparison results demonstrate that by incorporating a properly sized venturi in the DVI line, core uncovery concerns as a result of a DVI line break can be eliminated for both the AP600 and APWR plants. (author)

  5. Evaluation of ATLAS 100% DVI Line Break Using TRACE Code

    International Nuclear Information System (INIS)

    Huh, Byung Gil; Bang, Young Seok; Cheong, Ae Ju; Woo, Sweng Woong

    2011-01-01

    ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation) is an integral effect test facility in KAERI. It had installed completely to simulate the accident for the OPR1000 and the APR1400 in 2005. After then, several tests for LBLOCA, DVI line break have been performed successfully to resolve the safety issues of the APR1400. Especially, a DVI line break is considered as another spectrum among the SBLOCAs in APR1400 because the DVI line is directly connected to the reactor vessel and the thermal hydraulic behaviors are expected to be different from those for the cold leg injection. However, there are not enough experimental data for the DVI line break. Therefore, integral effect data for the DVI line break of ATLAS is very useful and available for an improvement and validation of safety codes. For the DVI line break in ATLAS, several analyses using MARS and RELAP codes were performed in the ATLAS DSP (Domestic Standard Problem) meetings. However, TRACE code has still not used to simulate a DVI line break. TRACE code has developed as the unified code for the reactor thermal hydraulic analyses in USNRC. In this study, the 100% DVI line break in ATLAS was evaluated by TRACE code. The objectives of this study are to identify the prediction capability of TRACE code for the major thermal hydraulic phenomena of a DVI line break in ATLAS

  6. Assessment of MARS for downcomer multi-dimensional thermal hydraulics during LBLOCA reflood using KAERI air-water direct vessel injection tests

    Energy Technology Data Exchange (ETDEWEB)

    Won-Jae, Lee; Kwi-Seok, Ha; Chul-Hwa, Song [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2001-07-01

    The MARS code has been assessed for the downcomer multi-dimensional thermal hydraulics during a large break loss-of-coolant accident (LBLOCA) reflood of Korean Next Generation Reactor (KNGR) that adopted an upper direct vessel injection (DVI) design. Direct DVI bypass and downcomer level sweep-out tests carried out at 1/50-scale air-water DVI test facility are simulated to examine the capability of MARS. Test conditions are selected such that they represent typical reflood conditions of KNGR, that is, DVI injection velocities of 1.0 {approx} 1.6 m/sec and air injection velocities of 18.0 {approx} 35.0 m/sec, for single and double DVI configurations. MARS calculation is first adjusted to the experimental DVI film distribution that largely affects air-water interaction in a scaled-down downcomer, then, the code is assessed for the selected test matrix. With some improvements of MARS thermal-hydraulic (T/H) models, it has been demonstrated that the MARS code is capable of simulating the direct DVI bypass and downcomer level sweep-out as well as the multi-dimensional thermal hydraulics in downcomer, where condensation effect is excluded. (authors)

  7. Direct vessel inclined injection system for reduction of emergency core coolant direct bypass in advanced reactors

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Lee, Jong G.; Suh, Kune Y.

    2006-01-01

    Multidimensional thermal hydraulics in the APR1400 (Advanced Power Reactor 1400 MWe) downcomer during a large-break loss-of-coolant accident (LBLOCA) plays a pivotal role in determining the capability of the safety injection system. APR1400 adopts the direct vessel injection (DVI) method for more effective core penetration of the emergency core cooling (ECC) water than the cold leg injection (CLI) method in the OPR1000 (Optimized Power Reactor 1000 MWe). The DVI method turned out to be prone to occasionally lack in efficacious delivery of ECC to the reactor core during the reflood phase of a LBLOCA, however. This study intends to demonstrate a direct vessel inclined injection (DVII) method, one of various ideas with which to maximize the ECC core penetration and to minimize the direct bypass through the break during the reflood phase of a LBLOCA. The 1/7 scaled down THETA (Transient Hydrodynamics Engineering Test Apparatus) tests show that a vertical inclined nozzle angle of the DVII system increases the downward momentum of the injected ECC water by reducing the degree of impingement on the reactor downcomer, whereby lessening the extent of the direct bypass through the break. The proposed method may be combined with other innovative measures with which to ensure an enough thermal margin in the core during the course of a LBLOCA in APR1400

  8. Comparison of the DVI line break LOCA with the equivalent cold leg break with the ATLAS facility

    International Nuclear Information System (INIS)

    Choi, K. Y.; Cho, S.; Kang, K. H.; Park, H. S.; Kim, Y. S.; Baek, W. P.

    2010-01-01

    The APR1400 (Advanced Power Reactor, 1400 MWe) adopts a DVI (Direct Vessel Injection) method for ECC (Emergency Core Cooling) water delivery rather than a conventional CLI (Cold Leg Injection) method as an advanced safety feature. The break scenario of one DVI nozzle is taken into account in the small break LOCA analysis. Transient behavior during the DVI line breaks needs to be investigated and compared with the equivalent break on the cold leg. An 8.5-inch double-ended break of one DVI nozzle was simulated with the ATLAS, and a counterpart test for the DVI break was performed at the cold leg with the equivalent break size for comparison. This comparison will contribute to enhancing a comprehensive understanding of the thermal hydraulic behavior during transients. A constructed integral effect database is also used to validate the existing conservative safety analysis methodology and to develop a best-estimate safety analysis methodology for small-break LOCAs. A post-test calculation was performed with a best-estimate safety analysis code, MARS 3.1, in order to examine its prediction capability and to identify any code deficiencies for thermal hydraulic phenomena occurring during the transient. (authors)

  9. Sensitivity Analysis for Residual Stress on DVI (Direct Vessel Injection) Nozzle Welded Joint

    International Nuclear Information System (INIS)

    Noh, Byeong Wook; Chung, Sung Ho; Lee, Jung Hun; Kim, Oak Sug

    2008-01-01

    Generally, any welding process produces high compressive or tensile residual stresses in the heat affected zone depending on the method, shape and procedures of the weldment. In particular, the tensile residual stresses have a considerable effect on the material strength, fatigue strength and corrosion cracking. For this reason, it is important that some knowledge of the internal stress state be deduced either from measurements or from modeling predictions. In this study, the residual stresses after a multi-pass welding process for DVI nozzle welding joint were evaluated by a numerical simulation method. The welding joint considered three weld joint angles of 40 deg., 6 deg. and 2 deg. Computations were made using a 2-D finite element model based on the simulation of cooling from the heat treatment temperature to room temperature with two cooling conditions at the inside surface. In these results, it is shown that the residual stress increased at the inner surface, when water cooling was applied to the inner surface, and axial compressive residual stress increased at the inner surface when the joint angle was decreased. (authors)

  10. Sensitivity Analysis for Residual Stress on DVI (Direct Vessel Injection) Nozzle Welded Joint

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Byeong Wook; Chung, Sung Ho; Lee, Jung Hun; Kim, Oak Sug [DOOSAN Heavy Industries and Construction Co. LTD, Reactor Design Team, 555 Guygok-dong Changwon (Korea, Republic of)

    2008-07-01

    Generally, any welding process produces high compressive or tensile residual stresses in the heat affected zone depending on the method, shape and procedures of the weldment. In particular, the tensile residual stresses have a considerable effect on the material strength, fatigue strength and corrosion cracking. For this reason, it is important that some knowledge of the internal stress state be deduced either from measurements or from modeling predictions. In this study, the residual stresses after a multi-pass welding process for DVI nozzle welding joint were evaluated by a numerical simulation method. The welding joint considered three weld joint angles of 40 deg., 6 deg. and 2 deg. Computations were made using a 2-D finite element model based on the simulation of cooling from the heat treatment temperature to room temperature with two cooling conditions at the inside surface. In these results, it is shown that the residual stress increased at the inner surface, when water cooling was applied to the inner surface, and axial compressive residual stress increased at the inner surface when the joint angle was decreased. (authors)

  11. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  12. Environmental Assisted Fatigue Evaluation of Direct Vessel Injection Piping Considering Thermal Stratification

    International Nuclear Information System (INIS)

    Kim, Taesoon; Lee, Dohwan

    2016-01-01

    As the environmentally assisted fatigue (EAF) due to the primary water conditions is to be a critical issue, the fatigue evaluation for the components and pipes exposed to light water reactor coolant conditions has become increasingly important. Therefore, many studies to evaluate the fatigue life of the components and pipes in LWR coolant environments on fatigue life of materials have been conducted. Among many components and pipes of nuclear power plants, the direct vessel injection piping is known to one of the most vulnerable pipe systems because of thermal stratification occurred in that systems. Thermal stratification occurs because the density of water changes significantly with temperature. In this study, fatigue analysis for DVI piping using finite element analysis has been conducted and those results showed that the results met design conditions related with the environmental fatigue evaluation of safety class 1 pipes in nuclear power plants. Structural and fatigue integrity for the DVI piping system that thermal stratification occurred during the plant operation has conducted. First of all, thermal distribution of the piping system is calculated by computational fluid dynamic analysis to analyze the structural integrity of that piping system. And the fatigue life evaluation considering environmental effects was carried out. Our results showed that the DVI piping system had enough structural integrity and fatigue life during the design lifetime of 60 years

  13. Analysis of emergency core cooling capability of direct vessel vertical injection using CFX

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Yu, Yong H.; Suh, Kune Y.

    2003-01-01

    More reliable and efficient safety injection system is of utmost importance in the design of advanced reactors such as the APR1400 (Advanced Power Reactor 1400 MWe). In this work, a new idea is proposed to inject the Emergency Core Cooling (ECC) water utilizing a dedicated nozzle with a vertically downward elbow. The Direct Vessel Injection (DVI) system is located horizontally above the cold leg in the APR1400. However, the horizontal injection method may not always satisfy the ECC penetration requirement into the core on account of rather involved multidimensional thermal and hydraulic phenomena occurring in the annular reactor downcomer such as bypass, impingement, entrainment and sweepout, condensation oscillation, etc. Thus, a novel concept is called for from the reactor safety point of view. The Direct Vessel Vertical Injection (DVVI) system is one of these efforts to penetrate as much the ECC water through the downcomer into the core as is practically achievable. The DVVI system can increase the momentum of the downward flow, thus minimizing the effect of water impingement on the core barrel and the direct bypass though the break. To support the claim of increased downward momentum of flow in the DVVI system, computational fluid dynamics analyses were performed using CFX. The new concept of the DVVI system, which can certainly help increase the core thermal margin, is found to be more efficient than DVI. If the structural problem in the manufacturing process is properly solved, this concept can safely be applied in the advanced nuclear reactor design

  14. Onset of liquid droplet entrainment on a direct vessel injection system for APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-sol; Lee, Jae-Young [Handong Global University, Pohang (Korea, Republic of); Kim, Jong-Rok; Euh, Dong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this research, a series of visualization works was conducted to understand droplet entrainment of the flow pattern generated in direct vessel injection system(DVI) of Korea nuclear power plant, APR 1400. In the emergency situation of a nuclear power plant, reliability of DVI cooling can be an important issue. It is known that, the amount and the rate of entrainment during the DVI cooling process can significantly affect the total heat removal. To visualize the film Reynolds number closely related with onset of droplet entrainment induced by falling film flow and lateral air flow in a small gap, confocal chromatic sensing method for measuring accurately film thickness and depth averaging particle image velocimetry for film velocity were used. The results have been post processed 4G Insight software. By measuring two dimensional film Reynolds number, we can predict the onset of droplet entrainment and obtain visible breakup region intuitively. To visualize the droplet entrainment induced by falling film flow and lateral air flow in a small gap, shadowgraph method with CCD camera (2200fps, 1280 pixel X 800 pixel, ) on coated plate with super water-repellent agent was used. The results have been post processed using 4G Insight software. By measuring two dimensional film Reynolds number, we can predict the onset of droplet entrainment and obtain visible breakup region intuitively. By adopting both super hydrophobic coating method and shadowgraph method, entrainment in a narrow gap was successfully visualized that has rarely performed before and meaningful results for DVI system research fields have been made.

  15. Onset of liquid droplet entrainment on a direct vessel injection system for APR1400

    International Nuclear Information System (INIS)

    Kim, Han-sol; Lee, Jae-Young; Kim, Jong-Rok; Euh, Dong-Jin

    2016-01-01

    In this research, a series of visualization works was conducted to understand droplet entrainment of the flow pattern generated in direct vessel injection system(DVI) of Korea nuclear power plant, APR 1400. In the emergency situation of a nuclear power plant, reliability of DVI cooling can be an important issue. It is known that, the amount and the rate of entrainment during the DVI cooling process can significantly affect the total heat removal. To visualize the film Reynolds number closely related with onset of droplet entrainment induced by falling film flow and lateral air flow in a small gap, confocal chromatic sensing method for measuring accurately film thickness and depth averaging particle image velocimetry for film velocity were used. The results have been post processed 4G Insight software. By measuring two dimensional film Reynolds number, we can predict the onset of droplet entrainment and obtain visible breakup region intuitively. To visualize the droplet entrainment induced by falling film flow and lateral air flow in a small gap, shadowgraph method with CCD camera (2200fps, 1280 pixel X 800 pixel, ) on coated plate with super water-repellent agent was used. The results have been post processed using 4G Insight software. By measuring two dimensional film Reynolds number, we can predict the onset of droplet entrainment and obtain visible breakup region intuitively. By adopting both super hydrophobic coating method and shadowgraph method, entrainment in a narrow gap was successfully visualized that has rarely performed before and meaningful results for DVI system research fields have been made

  16. Direct ECC bypass phenomena in the MIDAS test facility during LBLOCA reflood phase

    International Nuclear Information System (INIS)

    Yun, B. J.; Kweon, T. S.; Ah, D. J.; Ju, I. C.; Song, C. H.; Park, J. K.

    2001-01-01

    This paper describes the experimental results of ECC Direct Bypass Phenomena in the downcomer during the late reflood phase of LBLOCA of the reactor that adopts Direct Vessel Injection as a ECC system. The experiments have been performed in MIDAS test facility using superheated steam and water. The test condition was determined, based on the preliminary analysis of TRAC code, from modified linear scaling method of 1/4.93 length scale. To measure the direct bypass fraction according to the nozzle location, separate effect tests have been performed in case of DVI-4(farthest from broken cold leg) injection, DVI-2(closest to broken cold leg) injection, and DVI-2 and 4 injection, respectively. Also the test was carried out varying the steam flow rate greatly to investigate the effect of steam flow rate on the direct bypass fraction of ECC water. Test results show that the direct bypass fraction of ECC water depends significantly on the injected steam mass flow rate. DVI-4 tests show that the direct bypass fraction increases drastically as the steam flow rate increases. However, in DVI-2 test most of the injected ECC water penetrates into lower downcomer. The direct bypass characteristic in each of DVI-2 and DVI-4 tests is reflected into the direct bypass characteristic curve of DVI-2 and 4 test. The steam condensation reaches to the theoretically allowable maximum value

  17. ARP1400 DVI break analysis using the MARS 3.1 multi-D component

    International Nuclear Information System (INIS)

    Hwang, Moon-Kyu; Lim, Hong-Sik; Lee, Seung-Wook; Bae, Sung-Won; Chung, Bub-Dong

    2006-01-01

    The current version of MARS 3.1 has a multi-D component intended to simulate an asymmetric multidimensional fluid behavior in a reactor core, downcomer or in a steam generator, in a more realistic manner. The feature is implemented in the 1-D module of the code. As opposed to the cross flow junction modeling, the multi-D component allows for a lateral momentum transfer as well as a sheer stress. Thus, a full three-Dimensional analysis capability is available as in the case of RELAP5-3D or CATHARE. In this study the multi-D component is applied to the hypothetical accident of a DVI (Direct Vessel Injection) break in the APR1400 plant, and the results are analyzed

  18. Interaction of Liquid Film Flow of Direct Vessel Injection Under the Cross Directional Gas Flow

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-sol; Lee, Jae-young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness and a hydraulic jump in the film flow and boundaries of the film flow. It was found that CFD analysis results without surface tension model showed some difference with the data in surface tension dominated flow region. For the interaction between a liquid film and gas shear flow, CFD results make a good agreement with the real liquid film dynamics in the case of low film Reynolds number or low Weber number flow. In the 1/20 scaled plate type experiment and simulation, the deformed spreading profile results seem to accord with each other at the relatively low We and Re regime.

  19. An Overall Investigation of Direct Vessel Injection Line Break Accidents of the ATLAS Facility

    International Nuclear Information System (INIS)

    Kim, Yeon-Sik; Choi, Ki-Yong; Cho, Seok; Kim, Bok-Deuk

    2015-01-01

    For parametric evaluations of direct vessel injection (DVI) line break scenarios, the pressurizer (PZR) pressure, core collapsed water level, and peak cladding temperature were investigated between the analyses and tests. The PZR pressure was mainly dependent upon the break flow model, e.g., discharge coefficient of the Henry-Fauske critical model. The core collapsed water level and peak cladding temperature were mainly dependent on the counter-current flow limit (CCFL) option of the fuel alignment plate (FAP). The CCFL option of the cross-over leg (COL) affected the PZR pressure owing to the loop seal clearings and seemed to have little effect on the core collapsed water level. Proper C d values and applicable CCFL options were summarized. C d values seemed to be dependent on the sizes of the DVI line break. The PZR pressure was mainly dependent on the break flow model, e.g., the discharge coefficient of the Henry-Fauske critical model. The core collapsed water level and peak cladding temperature were mainly dependent on the CCFL option of the FAP. The CCFL option of the COL affected the PZR pressure owing to loop seal clearings and seemed to have little effect on the core collapsed water level. From parametric evaluations, proper C d values and applicable CCFL options were suggested. The C d values seemed to be dependent on the sizes of the DVI line break. Although there was little difference in the CCFL options of the COL, the Ku-option was the preferred one for COLs' CCFL option. The CCFL options of the FAP appeared sensitive to the core collapsed water level and peak cladding temperature. The Ku-option of the FAP tended to negatively exaggerate the core behavior and showed excessively conservative results, especially on the peak cladding temperature. For smaller breaks, e.g., 25%, NA- and Wa-options would be applicable for the FAP. However, for larger breaks, e.g., 50%, the Wa-option of the FAP was the preferred one. Comparisons between the tests and

  20. Analysis of the ISP-50 direct vessel injection SBLOCA in the ATLAS facility with the RELAP5/MOD3.3 code

    Energy Technology Data Exchange (ETDEWEB)

    Sharabi, Medhat; Freixa, Jordi [Paul Scherrer Institute, Nuclear Energy and Safety Department, Zurich (Sweden)

    2012-10-15

    The pressurized water reactor APR1400 adopts DVI (Direct Vessel Injection) for the emergency cooling water in the upper downcomer annulus. The International Standard Problem number 50 (ISP-50) was launched with the aim to investigate thermal hydraulic phenomena during a 50% DVI line break scenario with best estimate codes making use of the experimental data available from the ATLAS facility located at KAERI. The present work describes the calculation results obtained for the ISP-50 using the RELAP5/MOD3.3 system code. The work aims at validation and assessment of the code to reproduce the observed phenomena and investigate about its limitations to predict complicated mixing phenomena between the subcooled emergency cooling water and the two-phase flow in the downcomer. The obtained results show that the overall trends of the main test variables are well reproduced by the calculations. In particular, the pressure in the primary system show excellent agreement with the experiment. The loop seal clearance phenomenon was observed in the calculation and it was found to have an important influence on the transient progression. Moreover, the collapsed water levels in the core are accurately reproduced in the simulations. However, the drop in the downcomer level before the activation of the DVI from safety injection tanks was underestimated due to multi-dimensional phenomena in the downcomer that are not properly captured by one-dimensional simulations.

  1. Using DVI To Teach Physics: Making the Abstract More Concrete.

    Science.gov (United States)

    Knupfer, Nancy Nelson; Zollman, Dean

    The ways in which Digital Video Interactive (DVI), a new video technology, can help students learn concepts of physics were studied in a project that included software design and production as well as formative and summative evaluation. DVI provides real-time motion, with the full-motion image contained to a window on part of the screen so that…

  2. Double-Ended Break Test of an 8.5 inch Direct Vessel Injection Line using the ATLAS

    International Nuclear Information System (INIS)

    Choi, Ki Yong; Kang, Kyoung Ho; Kim, Bok Deuk; Kim, Yeon Sik; Min, Kyoung Ho; Park, Choon Kyoung; Park, Hyun Sik; Baek, Won Pil; Cho, Seok; Choi, Nam Hyun

    2010-01-01

    A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been constructed at the Korea Atomic Energy Research Institute (KAERI). It is a 1/2 reduced height and 1/288-volume scaled test facility with respect to the APR1400, an evolutionary pressurized water reactor developed by the Korean industry. In 2008, an integral effect test for simulating a guillotine break of a DVI line of the APR1400 was carried out as the first DVI test item, named as SB-DVI-03, on May, 2008. With an improvement on the break flow measuring system, the second DVI test for a guillotine break of a DVI line of the APR1400, named as SB-DVI-08, was conducted for repeatability. The present data is the first integral effect test data of its kind for simulating a DVI line break accident. It will help in understanding the thermal hydraulic phenomena occurring during the DVI line break accident. A post-test calculation was performed with a best-estimate safety analysis code MARS 3.1 to examine its prediction capability and to identify any code deficiencies for the thermal hydraulic phenomena occurring during the DVI line break accidents. The present integral effect test data will be used to validate the current safety analysis methodology for the DVI line break accident

  3. Scientific design of the test facility for the KNGR DVI line small break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Park, Choon Kyung; Jun, Hyung Gil; Cho, Seok; Kwon, Tae Soon; Song, Chul Hwa; Kim, Jung Taek

    1999-03-01

    Scientific design of the experimental facility (OASIS) for the KNGR (Korea Next Generation Reactor) DVI line SB-LOCA simulation is carried out. Main purpose of the OASIS is to produce thermal-hydraulic data base for determining the best location of the DVI (Direct Vessel Injection) injection nozzle of the KNGR as well as verifying its design performance in view of the ECCS (Emergency Core Cooling System) effectiveness. The experimental facility is designed based on the Ishii's three-level scaling law. The facility has 1/4 height and 1/341 area scaling ratio. It corresponds to the volume scale of 1/1364. The power scaling is 1/682 and the system pressure is prototypic. The OASIS consists of a core, a downcomer, two steam generators, two pump simulators, a break simulator, a collection tank, primary piping as well as a circulation pump for initial test condition. Each component is designed based on the Ishill's global scaling and boundary flow scaling of mass, energy and momentum. In addition, local phenomena scaling is carried out for the design of major components to preserve key local phenomena in each component. Most of the key phenomena are well preserved in the OASIS. However, the local scaling analysis shows that distortions of the void fraction and mixture level can not be avoided in the core. It comes from the basic features of the Ishill's scaling law in case of the reduced-height simulation. However, it is expected that these distortions will be analyzed properly by a best estimate system analysis code. (Author). 22 refs., 20 tabs., 25 figs.

  4. Visualization study of interaction with 2-D film flow on the vertical plate and lateral air velocity for DVI system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Sol; Lee, Jae Young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong Jin; Kim, Jong Rok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness. In this study, the average flow information of the downcomer was analyzed through the information about the thickness, speed, droplet size and speed of highly precise liquid film flow in the structure that occurs in a 2-dimensional liquid film flow, rather than film flow, onset of entrainment, droplet velocity, and size which have been studied in 1-dimension of the existing annular flow. The multi-dimensional flow characteristic information of downcomer can be utilized as the basic data for nuclear safety analysis in the future.

  5. Post-test analysis for the APR1400 LBLOCA DVI performance test using MARS

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Lee, Y. J.; Kim, H. C.; Bae, Y. Y.; Park, J. K.; Lee, W.

    2002-03-01

    Post-test analyses using a multi-dimensional best-estimate analysis code, MARS, are performed for the APR1400 LBLOCA DVI (Direct Vessel Injection) performance tests. This report describes the code evaluation results for the test data of various void height tests and direct bypass tests that have been performed at MIDAS test facility. MIDAS is a scaled test facility of APR1400 with the objective of identifying multi-dimensional thermal-hydraulic phenomena in the downcomer during the reflood conditions of a large break LOCA. A modified linear scale ratio was applied in its construction and test conditions. The major thermal-hydraulic parameters such as ECC bypass fraction, steam condensation fraction, and temperature distributions in downcomer are compared and evaluated. The evaluation results of MARS code for the various test cases show that: (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  6. Multi-dimensional Mixing Behavior of Steam-Water Flow in a Downcomer Annulus during LBLOCA Reflood Phase with a DVI Injection Mode

    International Nuclear Information System (INIS)

    Kwon, T.S.; Yun, B.J.; Euh, D.J.; Chu, I.C.; Song, C.H.

    2002-01-01

    Multi-dimensional thermal-hydraulic behavior in the downcomer annulus of a pressurized water reactor vessel with a Direct Vessel Injection (DVI) mode is presented based on the experimental observation in the MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) steam-water test facility. From the steady-state test results to simulate the late reflood phase of a Large Break Loss-of-Coolant Accidents(LBLOCA), isothermal lines show the multidimensional phenomena of a phasic interaction between steam and water in the downcomer annulus very well. MIDAS is a steam-water separate effect test facility, which is 1/4.93 linearly scaled-down of 1400 MWe PWR type of a nuclear reactor, focused on understanding multi-dimensional thermalhydraulic phenomena in downcomer annulus with various types of safety injection during the refill or reflood phase of a LBLOCA. The initial and the boundary conditions are scaled from the pre-test analysis based on the preliminary calculation using the TRAC code. The superheated steam with a superheating degree of 80 K at a given downcomer pressure of 180 kPa is injected equally through three intact cold legs into the downcomer. (authors)

  7. Integration of an open interface PC scene generator using COTS DVI converter hardware

    Science.gov (United States)

    Nordland, Todd; Lyles, Patrick; Schultz, Bret

    2006-05-01

    Commercial-Off-The-Shelf (COTS) personal computer (PC) hardware is increasingly capable of computing high dynamic range (HDR) scenes for military sensor testing at high frame rates. New electro-optical and infrared (EO/IR) scene projectors feature electrical interfaces that can accept the DVI output of these PC systems. However, military Hardware-in-the-loop (HWIL) facilities such as those at the US Army Aviation and Missile Research Development and Engineering Center (AMRDEC) utilize a sizeable inventory of existing projection systems that were designed to use the Silicon Graphics Incorporated (SGI) digital video port (DVP, also known as DVP2 or DD02) interface. To mate the new DVI-based scene generation systems to these legacy projection systems, CG2 Inc., a Quantum3D Company (CG2), has developed a DVI-to-DVP converter called Delta DVP. This device takes progressive scan DVI input, converts it to digital parallel data, and combines and routes color components to derive a 16-bit wide luminance channel replicated on a DVP output interface. The HWIL Functional Area of AMRDEC has developed a suite of modular software to perform deterministic real-time, wave band-specific rendering of sensor scenes, leveraging the features of commodity graphics hardware and open source software. Together, these technologies enable sensor simulation and test facilities to integrate scene generation and projection components with diverse pedigrees.

  8. Effects of commercial doses of γ-irradiation on DVI (Dormancy overcoming Visual Index) of red garlic clove (Allium sativum L.)

    International Nuclear Information System (INIS)

    Pellegrini, C.N.; Mujica, M.B.; Orioli, G.A.; Croci, C.A.

    1995-01-01

    The growth inhibitor effect of commercial doses of gamma rays was analyzed on the DVI evolution during garlic post-harvest storage. The DVI behaviour of irradiated and non-irradiated samples was identical throughout the rest period (90 d.p.h.) and the beginning of sprouting (120 d.p.h.). At 180 d.p.h. non-irradiated samples showed a sharp increase of DVI, reaching the maximum value at 240 d.p.h. At the same time irradiated samples only showed a slight index increase, hardly reaching 60%. These results are discussed in relation to the use of DVI as a possible indicator of irradiation treatment on garlic bulbs. (author). 9 refs, 3 figs

  9. Effects of commercial doses of {gamma}-irradiation on DVI (Dormancy overcoming Visual Index) of red garlic clove (Allium sativum L.)

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, C.N.; Mujica, M.B.; Orioli, G.A. [Universidad Nacional del Sur, Bahia Blanca (Argentina). Dept. de Agronomia; Croci, C.A. [Universidad Nacional del Sur, Bahia Blanca (Argentina). Lab. de Radioisotopos

    1995-12-31

    The growth inhibitor effect of commercial doses of gamma rays was analyzed on the DVI evolution during garlic post-harvest storage. The DVI behaviour of irradiated and non-irradiated samples was identical throughout the rest period (90 d.p.h.) and the beginning of sprouting (120 d.p.h.). At 180 d.p.h. non-irradiated samples showed a sharp increase of DVI, reaching the maximum value at 240 d.p.h. At the same time irradiated samples only showed a slight index increase, hardly reaching 60%. These results are discussed in relation to the use of DVI as a possible indicator of irradiation treatment on garlic bulbs. (author). 9 refs, 3 figs.

  10. Post-test analysis for the MIDAS DVI tests using MARS

    International Nuclear Information System (INIS)

    Bae, K. H.; Lee, Y. J.; Kwon, T. S.; Lee, W. J.; Kim, H. C.

    2002-01-01

    Various DVI tests have been performed at MIDAS test facility which is a scaled facility of APR1400 applying a modified linear scale ratio. The evaluation results for the various void height tests and direct bypass tests using a multi-dimensional best-estimate analysis code MARS, show that; (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  11. Application of gamma densitometer for void fraction measurement in the downcomer of DVI experimental apparatus

    International Nuclear Information System (INIS)

    Chu, In Cheol; Kim, Y. K.; Yun, B. J.; Kwon, T. S.; Chung, M. K.; Song, C. H.

    2000-11-01

    KNGR which adopts the DVI type of ECCS is expected to show different thermal hydraulic aspects from existing NPPs which use the CLI type of ECCS. Therefore, it is necessary to examine whether existing safety analysis codes could correctly predict major thermal hydraulic phenomena which are inherent in SIS operation of DVI type. Among several thermal hydraulic phenomena, it is of particular importance to examine and improve the analyzing capability of existing codes for the void fraction and flow pattern in the downcomer. In the present study, the design of gamma densitometer to measure the void fraction and flow pattern in the downcomer of DVI test apparatus has been performed. In addition, provided are the requirements of gamma source, source activity, scintillation detector, and signal processing system. Also, the design of the shielding facilities has been carried out to ensure the safety of operator from the danger of radiation exposure. And finally the applicability of gamma densitometer to the density measurement of two-phase flow has been investigated throughout the preliminary tests

  12. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  13. Air-water mixing experiments for direct vessel injection of KNGR

    International Nuclear Information System (INIS)

    Hwang, Do Hyun

    2000-02-01

    Two air-water mixing experiments are conducted to understand the flow behavior in the downcomer for Direct Vessel Injection (DVI) of Korean Next Generation Reactor (KNGR). In the first experiment which is an air-water experiment in the rectangular channel with the gap size of 1cm, the width of water film is proportional to the water and air velocities and the inclined angle is proportional to the water velocity only, regardless of the water velocity injected in the rectangular channel. It is observed that the amount of entrained water is negligible. In the second experiment which is a full-scaled water jetting experiment without air flow, the width of water film is proportional to the flow rate injected from the pipe exit and the film thickness of water varies from 1.0mm to 5.0mm, and the maximum thickness does not exceed 5.0mm. The amount of water separated from the liquid film after striking of water jetting on the wall is measured. The amount of separation water is proportional to the flow rate, but the separation ratio in the full-scaled water jetting is not over 15%. A simplified physical model, which is designed to predict the trajectories of the width of water film, is validated through the comparison with experiment results. The 13 .deg. upward water droplet of the water injected from the pipe constitutes the outermost boundary at 1.7m below from pipe level, after the water impinges against the wall. In the model, the parameter, η which represents the relationship between the jetting velocity and the initial spreading velocity, is inversely proportional to the water velocity when it impinges against the wall. The error of the predictions by the model is decreased within 14% to the experimental data through use of exponential fitting of η for the jetting water velocity

  14. The role of forensic anthropology in Disaster Victim Identification (DVI).

    Science.gov (United States)

    Blau, Soren; Briggs, Christopher A

    2011-02-25

    This paper briefly describes Disaster Victim Identification (DVI) and reviews the history of the use of forensic anthropology in the identification process. The potential contributions made by forensic anthropology are illustrated through the presentation of a case study. In February 2009 the state of Victoria in south-eastern Australia experienced the most devastating bushfires in its history, resulting in catastrophic loss of life and public and private property. Within 48h of the disaster, forensic teams including pathologists, odontologists and anthropologists assembled at the Victorian Institute of Forensic Medicine in Melbourne to begin the task of identifying the deceased. This paper reviews the part played by forensic anthropologists in the identification process and outlines the important contribution anthropologists can make to DVI, especially at the scene, in the mortuary and in the reconciliation process. The anthropologist's experience with differentially preserved human remains meant they played an important role identifying and recovering heavily fragmentary human skeletal remains, differentiating human from non-human remains, establishing basic biological information such as the sex and age of the individuals and confirming or denying the possibility of re-associating body parts for release to families. Crown Copyright © 2010. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Oryong 501 sinking incident in the Bering Sea-International DVI cooperation in the Asia Pacific.

    Science.gov (United States)

    Chung, Nak-Eun; Castilani, Anton; Tierra, Wilfredo E; Beh, Philip; Mahmood, Mohd Shah

    2017-09-01

    On December 1st, 2014, the sinking of Oryong 501 occurred in the Bering Sea off the east coast of Russia. A total of 60 crew members, including 35 Indonesians, 13 Filipinos, 11 South Koreans and 1 Russian inspector were on board out of which only seven survived. Through an international rescue operation, the dead bodies of 27 were found and the remaining 26 crew are still missing. After transferring the dead bodies to the Busan Harbor in South Korea, the operation to identify the deceased began involving DVI teams from three countries: Korea, Indonesia and the Philippines. When a deep sea fishing boat sinks, it is very difficult to obtain antemortem data of the crew who had been on board for a long time. This is especially so if the crews are multinational. Further, the accuracy of the antemortem data provided by the families may be questionable, and the provided data is often not standardized. Despite the fact that the antemortem data were received in different formats, the identification process for the bodies of the 27 crew from the Oryong sinking was quickly completed through the cooperation among the three DVI teams. This case is an excellent example of how efficiently a DVI operation can be conducted in the Asia Pacific region. Issues raised during this operation should enable even better preparation for similar events in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. PRELIMINARY STUDY ON RELAP5 SIMULATION OF DVI LINE BREAK ACCIDENT IN THE ATLAS FACILITY USING BEST ESTIMATE PLUS UNCERTAINTY METHOD

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2017-03-01

    STUDI AWAL SIMULASI KECELAKAAN PUTUSNYA JALUR DVI PADA FASILITAS ATLAS MENGGUNAKAN RELAP5 DENGAN METODE ESTIMASI TERBAIK DAN KETIDAKPASTIAN. Metode Best estimate plus uncertainty (BEPU adalah metode analisis keselamatan deterministik yang bertujuan untuk melakukan evaluasi keterbatasan program perhitungan dalam mensimulasikan sifat-sifat fisis instalasi secara realistik dengan mengkuantifikasi rentang ketidakpastian dari hasil perhitungan. Metode tersebut telah diterima secara luas dalam perijinan PLTN oleh badan pengatur dunia seperti di Amerika (USNRC, di Argentina, dan Kanada. Evaluasi ketidakpastian dalam metode BEPU dilakukan dengan beberapa metode yang berbeda seperti GRS, IRSN, ENUSA, AEAT, dan UNIPI. Atas dasar kompleksitas metode-metode yang lain, tujuan makalah ini adalah untuk menggambarkan aspek penting dari proses BEPU dengan metode GRS dengan melakukan simulasi putusnya jalur DVI sebesar 50% luasan pada fasilitas ATLAS karena analisis keselamatan yang dilakukan selama ini baru berupa perkiraan terbaik secara deterministik. Sebagai perbandingan dari simulasi perkiraan terbaik yang dilakukan dengan RELAP5/SCDAP/Mod3.4 digunakan data-data eksperimen yang telah terdokumentasi. Setelah dilakukan 100 simulasi, rentang ketidakpastian dari transien temperatur puncak kelongsong pemanas dan tekanan primer hanya mendekati data eksperimen pada 250 detik di periode awal. Oleh karena itu keakuratan dari simulasi perkiraan terbaik secara keseluruhan memiliki peranan penting pada hasil akhir dari analisis ketidakpastian karena perambatan perbedaan dengan data eksperimen akan terus terjadi selama simulasi. Setelah itu, pemilihan parameter yang penting untuk dikembangkan secara random harus dilakukan secara cermat dengan mempelajari fenomena-fenomena penting yang terkait dengan kejadian yang dianalisis dan model instalasinya. Kata kunci: perkiraan terbaik dan ketidakpastian, putusnya jalur DVI, fasilitas ATLAS, RELAP5, simulasi

  17. Ion transport membrane module and vessel system with directed internal gas flow

    Science.gov (United States)

    Holmes, Michael Jerome; Ohrn, Theodore R.; Chen, Christopher Ming-Poh

    2010-02-09

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an inlet adapted to introduce gas into the interior of the vessel, an outlet adapted to withdraw gas from the interior of the vessel, and an axis; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region; and (c) one or more gas flow control partitions disposed in the interior of the pressure vessel and adapted to change a direction of gas flow within the vessel.

  18. ISP-50 Specifications for a Direct Vessel Injection Line Break Test with the ATLAS

    International Nuclear Information System (INIS)

    Choi, Ki Yong; Baek, Won Pil; Kim, Yeon Sik; Park, Hyun Sik; Cho, Seok; Kang, Kyoung Ho; Choi, Nam Hyun; Min, Kyoung Ho

    2009-06-01

    An OECD/NEA International Standard Problem Exercise (ISP) focussing on a DVI line break simulation result with the ATLAS was approved by the NEA Committee on the Safety of Nuclear Installation (CSNI) meeting in December 2008 and was numbered by ISP-50. The ISP-50 program will be operated by an operating agency, KAERI for three years starting from the physical year 2009. Fourteen international organizations confirmed their participation in the ISP-50, including NRC (USA), JAEA, JNES (Japan), GRS (Germany), KFKI-AEKI (Hungary), EDO Gidropress (Russia), VTT, Fortum (Finland), NRI (Czech Republic), Univ. of Pisa (Italy), KINS, KNF, KOPEC, and KAERI (Korea). In addition, KTH in Sweden and HSE in UK are considering late participation. Recently, NPIC and CIAE in China hope to join the ISP-50. As for the safety analysis codes, nine codes are expected to be used for the ISP-50: MARS-3D, RELAP5- 3D, RELAP5, TRACE, CATHARE, APROS, ATHELET, TRAP, and KORSAR. It is the first ISP exercise in Korea in which a domestic test facility is utilized by international nuclear society and this exercise will contribute to extending our physical understanding on thermal hydraulic phenomena during the DVI line break accidents and to verifying the best-estimate thermal-hydraulic safety analysis codes. This report was prepared to define technical specifications of the ISP-50 exercise according the guideline provided by OECD/CSNI. It includes general objectives, phases, deliverables to participants, parameters required for comparison and the time table

  19. Direct bolus imaging of cervical blood vessels by means of MRI

    International Nuclear Information System (INIS)

    Satoh, Toshihiko; Fujioka, Mutsuhisa; Watari, Tsutomu; Nishimura, Gen; Matsumoto, Toshihiko; Washiya, Sumio; Inoue, Kiyoshi; Horita, Masatoshi; Shimizu, Kohji.

    1991-01-01

    Direct bolus imaging (DBI) is one of the non-invasive method for flow measurements which is based on the bolus tracking technique. DBI permits the direct visualization of flow velocity profiles and vessel band width. We performed screening for cervical vessel disease in patients with vertigo by means of DBI. MR system used here was 0.5 T superconducting imager-SMT-50A (Shimazu Co. Ltd). Pulse sequence parameters were TR= 60 ms, TE= 50 ms, NEX= 1, acquisition matrix; 128 x 256, slice thickness= 5 mm, with cardiac gating. Pulse sequence employed a slice selective RF pulse at the level of C5 vertebral body to tag a disk of fluid perpendicular to the direction of flow, followed by a gradient reforcussed echo. We evaluated each peak high and band width of the common-carotid arteries and the vertebral arteries. Seventy nine of 83 cases had optimal examinations. Abnormal findings of DBI were seen in 15 of 79 cases, (including 2 of subclavian steal syndrome, 1 of carotid obstruction, 5 of vertebral obstruction, 1 of basilar artery obstruction, and 6 of hypoplasia of vertebral artery). The abnormal findings of DBI were well correlated with those of angiographic examinations. We concluded that DBI was suitable to the screening for cervical vessel diseases in patients with vertigo, and should be added to the routine MR studies. (author)

  20. Best estimate small break LOCA analysis for KNGR SIS optimization

    International Nuclear Information System (INIS)

    Song, JIn Ho; Lim, Hong Sik; Bae, Kyoo Hwan; Lee, Joon

    1996-01-01

    The KNGR has an advanced ECCS design feature which employs four mechanically-separated SI trains where each train consisting of one HPSI pump and one SIT injects ECC water directly into the reactor vessel downcomer annulus. To demonstrate that the KNGR ECCS design features meet the EPRI ALWR requirements of no core uncovery for a break of up to 6 inch diameter, small break LOCA cases with various break sizes were analyzed using a best-estimate analytical procedure. Two kinds of break locations are considered: cold leg and DVI line breaks. It was observed that the KNGR ECCS design can tolerate a cold leg break of up to 10 inches with no core uncovery. However, since DVI line break with 6 inch diameter undergoes slight core uncovery, further investigation is required for KNGR SIS optimization

  1. Best-estimated multi-dimensional calculation during LB LOCA for APR1400

    International Nuclear Information System (INIS)

    Oh, D. Y.; Bang, Y. S.; Cheong, A. J.; Woong, S.; Korea, W.

    2010-01-01

    Best-estimated (BE) calculation with uncertainty quantification for the emergency core cooling system (ECCS) performance analysis during Loss of Coolant Accident (LOCA) is more broadly used in nuclear industries and regulations. In Korea, demand on regulatory audit calculation is continuously increasing to support the safety review for life extension, power up-rating and advanced nuclear reactor design. The thermal-hydraulic system code, MARS (Multi-dimensional Analysis of Reactor Safety), with multi-dimensional capability is used for audit calculation. It achieves to describe the complicated phenomena in reactor coolant system by very effectively consolidating the one dimensional RELAP5/MOD3 with the multidimensional COBRA-TF codes. The advanced power reactors (APR1400) to be evaluated has four separated hydraulic trains of the high pressure injection system (HPSI) with direct vessel injection (DVI) which is different from the existing commercial PWRs. Also, the therma-hydraulic behavior of DVI plant would be considerably different from that of a cold-leg safety injection since the low pressure safety injection system are eliminated and the high pressure safety flow are injected into the specific elevation of reactor vessel downcomer. The ECCS bypass induced by the downcomer boiling due to hot wall heating of reactor vessel during reflooding phase is one of the important phenomena which should be considered in DVI plants. Therefore, in this study, BE calculation with one-dimensional (1-D) and multi-dimensional (multi-D) MARS models during LBLOCA are performed for APR1400 plant. In the multi-D evaluation, the reactor vessel is modeled by multi-D components and the specific treatment of flow path inside reactor vessel, e.g., upper guide structure, is essential. The concept of hot zone is adopted to simulate the limiting thermal-hydraulic conditions surrounding hot rod, which is similar to hot channel in 1-D. Also, alternative treatment of the hot rods in multi-D is

  2. Scoping analyses for the safety injection system configuration for Korean next generation reactor

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Song, Jin Ho; Park, Jong Kyoon

    1996-01-01

    Scoping analyses for the Safety Injection System (SIS) configuration for Korean Next Generation Reactor (KNGR) are performed in this study. The KNGR SIS consists of four mechanically separated hydraulic trains. Each hydraulic train consisting of a High Pressure Safety Injection (HPSI) pump and a Safety Injection Tank (SIT) is connected to the Direct Vessel Injection (DVI) nozzle located above the elevation of cold leg and thus injects water into the upper portion of reactor vessel annulus. Also, the KNGR is going to adopt the advanced design feature of passive fluidic device which will be installed in the discharge line of SIT to allow more effective use of borated water during the transient of large break LOCA. To determine the feasible configuration and capacity of SIT and HPSl pump with the elimination of the Low Pressure Safety Injection (LPSI) pump for KNGR, licensing design basis evaluations are performed for the limiting large break LOCA. The study shows that the DVI injection with the fluidic device SlT enhances the SIS performance by allowing more effective use of borated water for an extended period of time during the large break LOCA

  3. Correlation analysis of the urban heat island effect and the spatial and temporal distribution of atmospheric particulates using TM images in Beijing

    International Nuclear Information System (INIS)

    Xu, L.Y.; Xie, X.D.; Li, S.

    2013-01-01

    This study combines the methods of observation statistics and remote sensing retrieval, using remote sensing information including the urban heat island (UHI) intensity index, the normalized difference vegetation index (NDVI), the normalized difference water index (NDWI), and the difference vegetation index (DVI) to analyze the correlation between the urban heat island effect and the spatial and temporal concentration distributions of atmospheric particulates in Beijing. The analysis establishes (1) a direct correlation between UHI and DVI; (2) an indirect correlation among UHI, NDWI and DVI; and (3) an indirect correlation among UHI, NDVI, and DVI. The results proved the existence of three correlation types with regional and seasonal effects and revealed an interesting correlation between UHI and DVI, that is, if UHI is below 0.1, then DVI increases with the increase in UHI, and vice versa. Also, DVI changes more with UHI in the two middle zones of Beijing. -- Highlights: •We analyze the correlation from the spatial and temporal views. •We present correlation analyses among UHI, NDWI, NDVI, and DVI from three perspectives. •Three correlations are proven to exist with regional and seasonal effects. •If UHI is below 0.1, then DVI increases with the increase in UHI, and vice versa. •The DVI changes more with UHI in the two middle zones of Beijing. -- Generally, if UHI is below 0.1 in the weak heat island or green island range, then DVI increases with the increase in UHI, and vice versa

  4. Blood vessel endothelium-directed tumor cell streaming in breast tumors requires the HGF/C-Met signaling pathway.

    Science.gov (United States)

    Leung, E; Xue, A; Wang, Y; Rougerie, P; Sharma, V P; Eddy, R; Cox, D; Condeelis, J

    2017-05-11

    During metastasis to distant sites, tumor cells migrate to blood vessels. In vivo, breast tumor cells utilize a specialized mode of migration known as streaming, where a linear assembly of tumor cells migrate directionally towards blood vessels on fibronectin-collagen I-containing extracellular matrix (ECM) fibers in response to chemotactic signals. We have successfully reconstructed tumor cell streaming in vitro by co-plating tumors cells, macrophages and endothelial cells on 2.5 μm thick ECM-coated micro-patterned substrates. We found that tumor cells and macrophages, when plated together on the micro-patterned substrates, do not demonstrate sustained directional migration in only one direction (sustained directionality) but show random bi-directional walking. Sustained directionality of tumor cells as seen in vivo was established in vitro when beads coated with human umbilical vein endothelial cells were placed at one end of the micro-patterned 'ECM fibers' within the assay. We demonstrated that these endothelial cells supply the hepatocyte growth factor (HGF) required for the chemotactic gradient responsible for sustained directionality. Using this in vitro reconstituted streaming system, we found that directional streaming is dependent on, and most effectively blocked, by inhibiting the HGF/C-Met signaling pathway between endothelial cells and tumor cells. Key observations made with the in vitro reconstituted system implicating C-Met signaling were confirmed in vivo in mammary tumors using the in vivo invasion assay and intravital multiphoton imaging of tumor cell streaming. These results establish HGF/C-Met as a central organizing signal in blood vessel-directed tumor cell migration in vivo and highlight a promising role for C-Met inhibitors in blocking tumor cell streaming and metastasis in vivo, and for use in human trials.

  5. An investigation of fluid mixing with safety injection in advanced reactors

    International Nuclear Information System (INIS)

    Cha, Jong Hee; Won, Soon Yean; Chung, Moon Ki; Jun, Hyung Gil

    1994-01-01

    The objective of this work is to investigate the fluid mixing phenomena in aspect of pressurized thermal shock(PTS) in an advanced PWR vessel downcomer during transient cooldown with safety injection. It provides comparison of fluid mixing characteristics between AP 600 DVI, designed by Westinghouse, and ABB CE System 80+ DVI, and the effects of deflector at the reactor downcomer. In order to investigate the fluid mixing phenomena in the downcomer of an advanced PWR, the flow visualization tests and the salt concentration tests were conducted in a 1/7-scale acrylic transparent model, which was designed and built based on AP 600 reactor geometry. The behaviour of the safety injection flow in downcomer associated with mixing phenomenon can be observed during visualization test, and time-dependent mixing rate between safety injection fluid and existing coolant can be determined with concentration test. Visualization tests were performed by the dye injection method. The results of concentration measurements were compared with the calculation using the REMIX code. During the tests, difference between AP 600 DVI flow and ABB CE System 80+ DVI flow and the effect of the deflector were observed

  6. Mechanical Recanalization of Subacute Vessel Occlusion in Peripheral Arterial Disease with a Directional Atherectomy Catheter

    Energy Technology Data Exchange (ETDEWEB)

    Massmann, Alexander, E-mail: Alexander.Massmann@uks.eu; Katoh, Marcus [Saarland University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Shayesteh-Kheslat, Roushanak [Saarland University Hospital, Department of General Surgery, Visceral, Vascular, and Pediatric Surgery (Germany); Buecker, Arno [Saarland University Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2012-10-15

    Purpose: To retrospectively examine the technical feasibility and safety of directional atherectomy for treatment of subacute infrainguinal arterial vessel occlusions. Methods: Five patients (one woman, four men, age range 51-81 years) with peripheral arterial disease who experienced sudden worsening of their peripheral arterial disease-related symptoms during the last 2-6 weeks underwent digital subtraction angiography, which revealed vessel occlusion in native popliteal artery (n = 4) and in-stent occlusion of the superficial femoral artery (n = 1). Subsequently, all patients were treated by atherectomy with the SilverHawk (ev3 Endovascular, USA) device. Results: The mean diameter of treated vessels was 5.1 {+-} 1.0 mm. The length of the occlusion ranged 2-14 cm. The primary technical success rate was 100%. One patient experienced a reocclusion during hospitalization due to heparin-induced thrombocytopenia. There were no further periprocedural complications, in particular no peripheral embolizations, until hospital discharge or during the follow-up period of 1 year. Conclusion: The recanalization of infrainguinal arterial vessel occlusions by atherectomy with the SilverHawk device is technically feasible and safe. In our limited retrospective study, it was associated with a high technical success rate and a low procedure-related complication rate.

  7. Comparison of Critical Flow Models' Evaluations for SBLOCA Tests

    International Nuclear Information System (INIS)

    Kim, Yeon Sik; Park, Hyun Sik; Cho, Seok

    2016-01-01

    A comparison of critical flow models between the Trapp-Ransom and Henry-Fauske models for all SBLOCA (small break loss of coolant accident) scenarios of the ATLAS (Advanced thermal-hydraulic test loop for accident simulation) facility was performed using the MARS-KS code. For the comparison of the two critical models, the accumulated break mass was selected as the main parameter for the comparison between the analyses and tests. Four cases showed the same respective discharge coefficients between the two critical models, e.g., 6' CL (cold leg) break and 25%, 50%, and 100% DVI (direct vessel injection) breaks. In the case of the 4' CL break, no reasonable results were obtained with any possible Cd values. In addition, typical system behaviors, e.g., PZR (pressurizer) pressure and collapsed core water level, were also compared between the two critical models. Four cases showed the same respective discharge coefficients between the two critical models, e.g., 6' CL break and 25%, 50%, and 100% DVI breaks. In the case of the 4' CL break, no reasonable results were obtained with any possible Cd values. In addition, typical system behaviors, e.g., PZR pressure and collapsed core water level, were also compared between the two critical models. From the comparison between the two critical models for the CL breaks, the Trapp-Ransom model predicted quite well with respect to the other model for the smallest and larger breaks, e.g., 2', 6', and 8.5' CL breaks. In addition, from the comparison between the two critical models for the DVI breaks, the Trapp-Ransom model predicted quite well with respect to the other model for the smallest and larger breaks, e.g., 5%, 50%, and 100% DVI breaks. In the case of the 50% and 100% breaks, the two critical models predicted the test data quite well.

  8. Mechanical Recanalization of Subacute Vessel Occlusion in Peripheral Arterial Disease with a Directional Atherectomy Catheter

    International Nuclear Information System (INIS)

    Massmann, Alexander; Katoh, Marcus; Shayesteh-Kheslat, Roushanak; Buecker, Arno

    2012-01-01

    Purpose: To retrospectively examine the technical feasibility and safety of directional atherectomy for treatment of subacute infrainguinal arterial vessel occlusions. Methods: Five patients (one woman, four men, age range 51–81 years) with peripheral arterial disease who experienced sudden worsening of their peripheral arterial disease–related symptoms during the last 2–6 weeks underwent digital subtraction angiography, which revealed vessel occlusion in native popliteal artery (n = 4) and in-stent occlusion of the superficial femoral artery (n = 1). Subsequently, all patients were treated by atherectomy with the SilverHawk (ev3 Endovascular, USA) device. Results: The mean diameter of treated vessels was 5.1 ± 1.0 mm. The length of the occlusion ranged 2–14 cm. The primary technical success rate was 100%. One patient experienced a reocclusion during hospitalization due to heparin-induced thrombocytopenia. There were no further periprocedural complications, in particular no peripheral embolizations, until hospital discharge or during the follow-up period of 1 year. Conclusion: The recanalization of infrainguinal arterial vessel occlusions by atherectomy with the SilverHawk device is technically feasible and safe. In our limited retrospective study, it was associated with a high technical success rate and a low procedure-related complication rate.

  9. Neonatal aortic arch reconstruction avoiding circulatory arrest and direct arch vessel cannulation.

    Science.gov (United States)

    Tchervenkov, C I; Korkola, S J; Shum-Tim, D; Calaritis, C; Laliberté, E; Reyes, T U; Lavoie, J

    2001-11-01

    Aortic arch reconstruction in neonates routinely requires deep hypothermic circulatory arrest. We reviewed our experience with techniques of continuous low-flow cerebral perfusion (LFCP) avoiding direct arch vessel cannulation. Eighteen patients, with a median age of 11 days (range 1 to 85 days) and a mean weight of 3.2 +/- 0.8 kg, underwent aortic arch reconstruction with LFCP. Seven had biventricular repairs with arch reconstruction, 9 underwent the Norwood operation and 2 had isolated arch repairs. In 1 Norwood and 7 biventricular repair patients, LFCP was maintained by advancing the cannula from the distal ascending aorta into the innominate artery. In 8 of 9 Norwood patients, LFCP was maintained by directing the arterial cannula into the pulmonary artery confluence and perfusing the innominate artery through the right modified Blalock-Taussig shunt fully constructed before cannulation for cardiopulmonary bypass. In 2 patients requiring isolated arch reconstruction, the ascending aorta was cannulated and the cross-clamp was applied just distal to the innominate artery. LFCP was maintained at 0.6 +/- 0.2 L x min(-1) x m(-2) for 41.0 +/- 13.9 minutes at 18.5 degrees C +/- 1.1 degrees C. In 10 of the 18 patients, blood pressure during LFCP was 15 +/- 8 mm Hg remote from the innominate artery (left radial, umbilical or femoral arteries). In 8 of the 18 patients, right radial pressure during LFCP was 24 +/- 10 mm Hg. The mean mixed-venous saturation was 79.8% +/- 10% during LFCP. Two patients had preoperative seizures, whereas none had seizures postoperatively. One patient died. Neonatal aortic arch reconstruction is possible without circulatory arrest or direct arch vessel cannulation. These techniques maintained adequate mixed-venous oxygen saturations with no associated adverse neurologic outcomes.

  10. Onset condition of the off take from the stratified region to the branch with arbitrary direction

    International Nuclear Information System (INIS)

    Lee, Jae Young; Choo, Kyo Seong; Kim, Man Woong

    2004-01-01

    Two phase discharge from a stratified region through single or multiple branches has been studied considerably in the past two decades. The flow distribution in the header-feeder system of CANDU(Canada Deuterium and Uranium) reactors during accident scenario is one of good examples of these applications. Recently, the passive safety feature for PWR(Pressurized Water Reactor) introduce the concept of DVI(Direct Vessel Injection) for the emergency core make up. The expected water sweep out phenomena needs careful models including the curvature effect of down comer shell and the multi branches. It has been generally accepted that the onset condition of the off take follows the 2.5 power law, but recently, Lee et al. discussed that the experimental data produced large scattering to the 2.5 power law. Also, the effect of branch angle on the onset point of off take remains still as an unsolved problem. Hwang et al produced the CANDU specific branch angles of 0, +-90, +-36, +-72. The experimental results showed severe deviation from the 2.5 power law and needs mechanistic understanding on these phenomena. In the present paper, we try to develop a general model of onset point including the branch orientation

  11. 75 FR 75486 - Maritime Security Directive 104-6 (Rev. 4); Guidelines for U.S. Vessels Operating in High Risk...

    Science.gov (United States)

    2010-12-03

    ... Directive 104-6 (Rev. 4); Guidelines for U.S. Vessels Operating in High Risk Waters AGENCY: Coast Guard, DHS... Maritime Transportation Security Act (MTSA) on international voyages through or in designated high risk... MARSEC Directives are available at your local Captain of the Port (COTP) office. Phone numbers and...

  12. Probabilistic retinal vessel segmentation

    Science.gov (United States)

    Wu, Chang-Hua; Agam, Gady

    2007-03-01

    Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.

  13. Direct-to-PCR tissue preservation for DNA profiling.

    Science.gov (United States)

    Sorensen, Amy; Berry, Clare; Bruce, David; Gahan, Michelle Elizabeth; Hughes-Stamm, Sheree; McNevin, Dennis

    2016-05-01

    Disaster victim identification (DVI) often occurs in remote locations with extremes of temperatures and humidities. Access to mortuary facilities and refrigeration are not always available. An effective and robust DNA sampling and preservation procedure would increase the probability of successful DNA profiling and allow faster repatriation of bodies and body parts. If the act of tissue preservation also released DNA into solution, ready for polymerase chain reaction (PCR), the DVI process could be further streamlined. In this study, we explored the possibility of obtaining DNA profiles without DNA extraction, by adding aliquots of preservative solutions surrounding fresh human muscle and decomposing human muscle and skin tissue samples directly to PCR. The preservatives consisted of two custom preparations and two proprietary solutions. The custom preparations were a salt-saturated solution of dimethyl sulfoxide (DMSO) with ethylenediaminetetraacetic (EDTA) and TENT buffer (Tris, EDTA, NaCl, Tween 20). The proprietary preservatives were DNAgard (Biomatrica(®)) and Tissue Stabilising Kit (DNA Genotek). We obtained full PowerPlex(®) 21 (Promega) and GlobalFiler(®) (Life Technologies) DNA profiles from fresh and decomposed tissue preserved at 35 °C for up to 28 days for all four preservatives. The preservative aliquots removed from the fresh muscle tissue samples had been stored at -80 °C for 4 years, indicating that long-term archival does not diminish the probability of successful DNA typing. Rather, storage at -80 °C seems to reduce PCR inhibition.

  14. UPTF test 21D counterpart test in the MIDAS test facility

    International Nuclear Information System (INIS)

    Yoon, B. C.; Ah, D. J.; Joo, I. C.; Kwon, T. S.; Park, W. M.; Song, C. H.

    2002-01-01

    This paper describes the experimental results of UPTF Test 21D counterpart tests in the downcomer during the late reflood phase of LBLOCA. The experiments have been performed in the MIDAS test facility using superheated steam and water. The test condition was determined,based on the test results of UPTF Test 21D, by applying the 'modified linear scaling method of 1/4.077 length scale. The tests of ECC direct bypass and void height are performed separately to estimate each phenomena quantitatively. The tests were carried out by varying the injection steam flow rate of intact cold legs widely to investigate the effect of steam flow rate on the direct bypass fraction and void height. In the tests, separate effect tests have been performed in cases of DVI-1,DVI- 2 and DVI-1 and 2 injections to see the direct bypass fraction according to the DVI nozzle combination. From the tests, we found that the fraction of direct ECC bypass and the void height observed in the MIDAS test facility reasonably well agree with those of UPTF test 21- D. It confirms that the applied 'modified linear scaling law' reproduces major thermal hydraulics phenomena in the downcomer during the LBLOCA reflood phase

  15. 76 FR 2402 - Maritime Security Directive 104-6 (Rev 5); Guidelines for U.S. Vessels Operating in High Risk Waters

    Science.gov (United States)

    2011-01-13

    ... Directive 104-6 (Rev 5); Guidelines for U.S. Vessels Operating in High Risk Waters AGENCY: Coast Guard, DHS... designated high risk waters, and provides additional counter-piracy guidance and mandatory measures for these... MARSEC Directives are available at your local Captain of the Port (COTP) office. Phone numbers and...

  16. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  17. Preliminary LOCA analysis of the westinghouse small modular reactor using the WCOBRA/TRAC-TF2 thermal-hydraulics code

    Energy Technology Data Exchange (ETDEWEB)

    Liao, J.; Kucukboyaci, V. N.; Nguyen, L.; Frepoli, C. [Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (> 225 MWe) integral pressurized water reactor (iPWR) with all primary components, including the steam generator and the pressurizer located inside the reactor vessel. The reactor core is based on a partial-height 17x17 fuel assembly design used in the AP1000{sup R} reactor core. The Westinghouse SMR utilizes passive safety systems and proven components from the AP1000 plant design with a compact containment that houses the integral reactor vessel and the passive safety systems. A preliminary loss of coolant accident (LOCA) analysis of the Westinghouse SMR has been performed using the WCOBRA/TRAC-TF2 code, simulating a transient caused by a double ended guillotine (DEG) break in the direct vessel injection (DVI) line. WCOBRA/TRAC-TF2 is a new generation Westinghouse LOCA thermal-hydraulics code evolving from the US NRC licensed WCOBRA/TRAC code. It is designed to simulate PWR LOCA events from the smallest break size to the largest break size (DEG cold leg). A significant number of fluid dynamics models and heat transfer models were developed or improved in WCOBRA/TRAC-TF2. A large number of separate effects and integral effects tests were performed for a rigorous code assessment and validation. WCOBRA/TRAC-TF2 was introduced into the Westinghouse SMR design phase to assist a quick and robust passive cooling system design and to identify thermal-hydraulic phenomena for the development of the SMR Phenomena Identification Ranking Table (PIRT). The LOCA analysis of the Westinghouse SMR demonstrates that the DEG DVI break LOCA is mitigated by the injection and venting from the Westinghouse SMR passive safety systems without core heat up, achieving long term core cooling. (authors)

  18. 33 CFR 88.11 - Law enforcement vessels.

    Science.gov (United States)

    2010-07-01

    ... NAVIGATION RULES ANNEX V: PILOT RULES § 88.11 Law enforcement vessels. (a) Law enforcement vessels may display a flashing blue light when engaged in direct law enforcement or public safety activities. This... lights. (b) The blue light described in this section may be displayed by law enforcement vessels of the...

  19. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  20. Vessel Enhancement and Segmentation of 4D CT Lung Image Using Stick Tensor Voting

    Science.gov (United States)

    Cong, Tan; Hao, Yang; Jingli, Shi; Xuan, Yang

    2016-12-01

    Vessel enhancement and segmentation plays a significant role in medical image analysis. This paper proposes a novel vessel enhancement and segmentation method for 4D CT lung image using stick tensor voting algorithm, which focuses on addressing the vessel distortion issue of vessel enhancement diffusion (VED) method. Furthermore, the enhanced results are easily segmented using level-set segmentation. In our method, firstly, vessels are filtered using Frangi's filter to reduce intrapulmonary noises and extract rough blood vessels. Secondly, stick tensor voting algorithm is employed to estimate the correct direction along the vessel. Then the estimated direction along the vessel is used as the anisotropic diffusion direction of vessel in VED algorithm, which makes the intensity diffusion of points locating at the vessel wall be consistent with the directions of vessels and enhance the tubular features of vessels. Finally, vessels can be extracted from the enhanced image by applying level-set segmentation method. A number of experiments results show that our method outperforms traditional VED method in vessel enhancement and results in satisfied segmented vessels.

  1. 2D time-of-flight MR angiography using concatenated saturation bands for determining direction of flow in the intracranial vessels

    International Nuclear Information System (INIS)

    Nesbit, G.M.; DeMarco, J.K.

    1997-01-01

    We prospectively studied 15 patients to assess 2D time-of-flight (TOF) magnetic resonance angiography (MRA) with concatenated saturation bands for determining the direction of intracranial blood flow. This MRA sequence was compared to T2-weighted spin-echo MRI, 3D-TOF MRA, and intra-arterial angiography (IAA) as regards demonstration of vessels and determination of the direction of flow in the circle of Willis and its branches. The 2D-TOF MRA sequence demonstrated flow in 98.5 % vessel segments identified on IAA, 3D-TOF demonstrating 92 % and spin-echo images 77 %. The direction of flow shown on the 2D-TOF sequence was correct in 94 % when compared to conventional angiography, the remaining six segments not demonstrating flow. In ten patients, the flow abnormalities demonstrated by this MRA technique provided clinical information similar to that of conventional angiography in nine, but it was incomplete in three, and misleading in one. Slow retrograde flow in ophthalmic artery collaterals and differentiation of arteries and veins presented some problems. 2D-TOF MRA with concatenated saturation bands provides flow direction information using widely available, easily applicable TOF techniques, and can be a useful adjunct to MRI and MRA if information on flow direction is needed. (orig.). With 5 figs., 3 tabs

  2. Nuclear reactor vessel decontamination systems

    International Nuclear Information System (INIS)

    McGuire, P. J.

    1985-01-01

    There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination

  3. DHCVIM - a direct heating containment vessel interactions module: applications to Sandia National Laboratories Surtsey experiments

    International Nuclear Information System (INIS)

    Ginsberg, T.; Tutu, N.K.

    1987-01-01

    Direct containment heating is the mechanism of severe nuclear reactor accident containment loading that results from transfer of thermal and chemical energy from high-temperature, finely divided, molten core material to the containment atmosphere. The direct heating containment vessel interactions module (DHCVIM) has been developed at Brookhaven National Laboratory to model the mechanisms of containment loading resulting from the direct heating accident sequence. The calculational procedure is being used at present to model the Sandia National Laboratories one-tenth-scale Surtsey direct containment heating experiments. The objective of the code is to provide a test bed for detailed modeling of various aspects of the thermal, chemical, and hydrodynamic interactions that are expected to occur in three regions of a containment building: reactor cavity, intermediate subcompartments, and containment dome. Major emphasis is placed on the description of reactor cavity dynamics. This paper summarizes the modeling principles that are incorporated in DHCVIM and presents a prediction of the Surtsey Test DCH-2 that was made prior to execution of the experiment

  4. Evaluating the break flow for the 100% DVI line break accident of ATLAS using the RELAP5/MOD3.3 code

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suk Ho; You, Sung Chang; Kim, Han Gon [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2010-10-15

    An integral effect test database for major design basis accidents using the Advanced Test Loop for Accident Simulation (ATLAS) facility has been compiled by the Korea Atomic Energy Research Institute (KAERI). In order to effectively utilize the database, the Domestic Standard Problem (DSP) exercise was proposed and launched in 2009. As the first DSP exercise, scenario involving a 100% break of the DVI nozzle was determined by considering its technical importance including such phenomena as the break flow, loop seal clearing. The first DSP exercise was performed in an open calculation environment. Thus, integral effect test data were opened to the participants prior to code calculations. Ten domestic organizations including members of nuclear industry, a research institute, and universities participated in the DSP exercise using various best-estimate safety analysis codes and finally presented their code prediction results, comparing them to the experimental data. This paper presents the analysis results performed by NETEC as one of the first DSP exercise participants. This analysis focuses on the break flow phenomena and modeling

  5. Application of morphological bit planes in retinal blood vessel extraction.

    Science.gov (United States)

    Fraz, M M; Basit, A; Barman, S A

    2013-04-01

    The appearance of the retinal blood vessels is an important diagnostic indicator of various clinical disorders of the eye and the body. Retinal blood vessels have been shown to provide evidence in terms of change in diameter, branching angles, or tortuosity, as a result of ophthalmic disease. This paper reports the development for an automated method for segmentation of blood vessels in retinal images. A unique combination of methods for retinal blood vessel skeleton detection and multidirectional morphological bit plane slicing is presented to extract the blood vessels from the color retinal images. The skeleton of main vessels is extracted by the application of directional differential operators and then evaluation of combination of derivative signs and average derivative values. Mathematical morphology has been materialized as a proficient technique for quantifying the retinal vasculature in ocular fundus images. A multidirectional top-hat operator with rotating structuring elements is used to emphasize the vessels in a particular direction, and information is extracted using bit plane slicing. An iterative region growing method is applied to integrate the main skeleton and the images resulting from bit plane slicing of vessel direction-dependent morphological filters. The approach is tested on two publicly available databases DRIVE and STARE. Average accuracy achieved by the proposed method is 0.9423 for both the databases with significant values of sensitivity and specificity also; the algorithm outperforms the second human observer in terms of precision of segmented vessel tree.

  6. Method of burying vessel containing radioactive waste

    International Nuclear Information System (INIS)

    Koga, Yoshihito.

    1989-01-01

    A float having an inert gas sealed therein is attached to a tightly closed vessel containing radioactive wastes. The vessel is inserted and kept in a small hole for burying the tightly closed vessel in an excavated shaft in rocks such as of granite or rock salts, while filling bentonite as shielding material therearound. In this case, the float is so adjusted that the apparent specific gravity is made equal or nearer between the tightly closed vessel and the bentonite, so that the rightly closed vessel does not sink and cause direct contact with the rocks even if bentonite flows due to earthquakes, etc. This can prevent radioactivity contamination through water in the rocks. (S.K.)

  7. Ligand-directed targeting of lymphatic vessels uncovers mechanistic insights in melanoma metastasis.

    Science.gov (United States)

    Christianson, Dawn R; Dobroff, Andrey S; Proneth, Bettina; Zurita, Amado J; Salameh, Ahmad; Dondossola, Eleonora; Makino, Jun; Bologa, Cristian G; Smith, Tracey L; Yao, Virginia J; Calderone, Tiffany L; O'Connell, David J; Oprea, Tudor I; Kataoka, Kazunori; Cahill, Dolores J; Gershenwald, Jeffrey E; Sidman, Richard L; Arap, Wadih; Pasqualini, Renata

    2015-02-24

    Metastasis is the most lethal step of cancer progression in patients with invasive melanoma. In most human cancers, including melanoma, tumor dissemination through the lymphatic vasculature provides a major route for tumor metastasis. Unfortunately, molecular mechanisms that facilitate interactions between melanoma cells and lymphatic vessels are unknown. Here, we developed an unbiased approach based on molecular mimicry to identify specific receptors that mediate lymphatic endothelial-melanoma cell interactions and metastasis. By screening combinatorial peptide libraries directly on afferent lymphatic vessels resected from melanoma patients during sentinel lymphatic mapping and lymph node biopsies, we identified a significant cohort of melanoma and lymphatic surface binding peptide sequences. The screening approach was designed so that lymphatic endothelium binding peptides mimic cell surface proteins on tumor cells. Therefore, relevant metastasis and lymphatic markers were biochemically identified, and a comprehensive molecular profile of the lymphatic endothelium during melanoma metastasis was generated. Our results identified expression of the phosphatase 2 regulatory subunit A, α-isoform (PPP2R1A) on the cell surfaces of both melanoma cells and lymphatic endothelial cells. Validation experiments showed that PPP2R1A is expressed on the cell surfaces of both melanoma and lymphatic endothelial cells in vitro as well as independent melanoma patient samples. More importantly, PPP2R1A-PPP2R1A homodimers occur at the cellular level to mediate cell-cell interactions at the lymphatic-tumor interface. Our results revealed that PPP2R1A is a new biomarker for melanoma metastasis and show, for the first time to our knowledge, an active interaction between the lymphatic vasculature and melanoma cells during tumor progression.

  8. Prestressed reactor vessel for nuclear power plants

    International Nuclear Information System (INIS)

    Schoening, J.; Schwiers, H.G.

    1982-01-01

    With usual pressure vessels for nuclear reactor plants, especially for gas-cooled nuclear reactors, the load occurring due to the inner overpressure, especially the tensile load affecting the vessel top and/or bottom, their axis of inertia being horizontal, shall be compensated without a supplementary modification in design of the top and/or the bottom. This is attained by choosing an appropriate prestressing system of the vessel wall in the field the top and/or the bottom, so that the top and/or the bottom form a tension vault directed towards the interior of the vessel. (orig.) [de

  9. Head spray nozzle in reactor pressure vessel

    International Nuclear Information System (INIS)

    Hatano, Shun-ichi.

    1990-01-01

    In a reactor pressure vessel of a BWR type reactor, a head spray nozzle is used for cooling the head of the pressure vessel and, in view of the thermal stresses, it is desirable that cooling is applied as uniformly as possible. A conventional head spray is constituted by combining full cone type nozzles. Since the sprayed water is flown down upon water spraying and the sprayed water in the vertical direction is overlapped, the flow rate distribution has a high sharpness to form a shape as having a maximum value near the center and it is difficult to obtain a uniform flow rate distribution in the circumferential direction. Then, in the present invention, flat nozzles each having a spray water cross section of laterally long shape, having less sharpness in the circumferential distribution upon spraying water to the inner wall of the pressure vessel and having a wide angle of water spray are combined, to make the flow rate distribution of spray water uniform in the inner wall of the pressure vessel. Accordingly, the pressure vessel can be cooled uniformly and thermal stresses upon cooling can be decreased. (N.H.)

  10. Vessel Monitoring Systems Study. Volume I - Technical Analysis.

    Science.gov (United States)

    1980-09-01

    In the Port and Tanker Safety Act of 1978 the U.S. Conress directed the Department of Transportation to performa a study on the desirability and feasibility of a shore-station system for monitoring vessels (including fishing vessels)offshore within t...

  11. Digital vascular imaging

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Engels, B.C.H.

    1981-01-01

    Digitalizing videosignals from an image intensifying TV-chain, followed by subtraction, contrast intensifying, and reformation to analogous signal deliver angiography pictures of high quality after intravenous injection of the contrast medium. As the examination is only little invasive it can be carried out on outdoor patients or in the polyclinics. The possibilities of the digital vessel imagination (DVI) are shown at vessel images of different parts of the body; a 36 cm image intensifyer which can be switched to 3 different sorts of operation and has a plumbicon-TV recording tube is used as receiver. (orig.) [de

  12. Automated identification of retinal vessels using a multiscale directional contrast quantification (MDCQ) strategy

    Energy Technology Data Exchange (ETDEWEB)

    Zhen, Yi; Zhang, Xinyuan; Wang, Ningli, E-mail: wningli@vip.163.com, E-mail: puj@upmc.edu [National Engineering Research Center for Ophthalmic Equipments, Beijing, 100730 (China); Gu, Suicheng; Meng, Xin [Imaging Research Center, Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, 15213 (United States); Zheng, Bin [School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States); Pu, Jiantao, E-mail: wningli@vip.163.com, E-mail: puj@upmc.edu [Imaging Research Center, Departments of Radiology and Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, 15213 (United States)

    2014-09-15

    Purpose: A novel algorithm is presented to automatically identify the retinal vessels depicted in color fundus photographs. Methods: The proposed algorithm quantifies the contrast of each pixel in retinal images at multiple scales and fuses the resulting consequent contrast images in a progressive manner by leveraging their spatial difference and continuity. The multiscale strategy is to deal with the variety of retinal vessels in width, intensity, resolution, and orientation; and the progressive fusion is to combine consequent images and meanwhile avoid a sudden fusion of image noise and/or artifacts in space. To quantitatively assess the performance of the algorithm, we tested it on three publicly available databases, namely, DRIVE, STARE, and HRF. The agreement between the computer results and the manual delineation in these databases were quantified by computing their overlapping in both area and length (centerline). The measures include sensitivity, specificity, and accuracy. Results: For the DRIVE database, the sensitivities in identifying vessels in area and length were around 90% and 70%, respectively, the accuracy in pixel classification was around 99%, and the precisions in terms of both area and length were around 94%. For the STARE database, the sensitivities in identifying vessels were around 90% in area and 70% in length, and the accuracy in pixel classification was around 97%. For the HRF database, the sensitivities in identifying vessels were around 92% in area and 83% in length for the healthy subgroup, around 92% in area and 75% in length for the glaucomatous subgroup, around 91% in area and 73% in length for the diabetic retinopathy subgroup. For all three subgroups, the accuracy was around 98%. Conclusions: The experimental results demonstrate that the developed algorithm is capable of identifying retinal vessels depicted in color fundus photographs in a relatively reliable manner.

  13. Towards a new pressure vessel standard in the European Union

    International Nuclear Information System (INIS)

    Osweiller, F.

    1995-01-01

    Since 1990 the European Commission has been preparing a new Directive which will regulate the Pressure Equipment sector in the countries of the European Union. CEN Standards devoted to pressure vessels, piping, boilers, are currently being drawn up to complete and implement this Directive. This paper focuses on the European Unfired Pressure Vessel Standard (EPVS) which is in course of development under the responsibility of CEN/TC54. The main aspects of the Standard are outlined: general structure, materials, design, fabrication, inspection and testing. The link with the European Directive is explained in connection with regulatory aspects: conformity assessment, essential safety requirements, classes of vessels, notified bodies, EC mark, status of the standard

  14. Effects of Core Cavity on a Flow Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Tae-Soon; Kim, Kihwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The axial pressure drop is removed in the free core condition, But the actual core has lots of fuel bundles and mixing vanes to the flow direction. The axial pressure drop induces flow uniformity. In a uniform flow having no shear stress, the cross flow or cross flow mixing decreases. The mixing factor is important in the reactor safety during a Steam Line Break (SLB) or Main Steam Line Break (MSLB) transients. And the effect of core cavity is needed to evaluate the realistic core mixing factor quantification. The multi-dimensional flow mixing phenomena in a core cavity has been studied using a CFD code. The 1/5-scale model was applied for the reactor flow analysis. A single phase water flow conditions were considered for the 4-cold leg and DVI flows. To quantify the mixing intensity, a boron scalar was introduced to the ECC injection water at cold legs and DVI nozzles. The present CFD pre-study was performed to quantify the effects of core structure on the mixing phenomena. The quantified boron mixing scalar in the core simulator model represented the effect of core cavity on the core mixing phenomena. This simulation results also give the information for sensor resolution to measure the boron concentration in the experiments and response time to detect mixing phenomena at the core and reactor vessel.

  15. Experimental results of direct containment heating by high-pressure melt ejection into the Surtsey vessel: The DCH-3 and DCH-4 tests

    International Nuclear Information System (INIS)

    Allen, M.D.; Pilch, M.; Brockmann, J.E.; Tarbell, W.W.; Nichols, R.T.; Sweet, D.W.

    1991-08-01

    Two experiments, DCH-3 and DCH-4, were performed at the Surtsey test facility to investigate phenomena associated with a high-pressure melt ejection (HPME) reactor accident sequence resulting in direct containment heating (DCH). These experiments were performed using the same experimental apparatus with identical initial conditions, except that the Surtsey test vessel contained air in DCH-3 and argon in DCH-4. Inerting the vessel with argon eliminated chemical reactions between metallic debris and oxygen. Thus, a comparison of the pressure response in DCH-3 and DCH-4 gave an indication of the DCH contribution due to metal/oxygen reactions. 44 refs., 110 figs., 43 tabs

  16. Experimental results of direct containment heating by high-pressure melt ejection into the Surtsey vessel: The DCH-3 and DCH-4 tests

    Energy Technology Data Exchange (ETDEWEB)

    Allen, M.D.; Pilch, M.; Brockmann, J.E.; Tarbell, W.W. (Sandia National Labs., Albuquerque, NM (United States)); Nichols, R.T. (Ktech Corp., Albuquerque, NM (United States)); Sweet, D.W. (AEA Technology, Winfrith (United Kingdom))

    1991-08-01

    Two experiments, DCH-3 and DCH-4, were performed at the Surtsey test facility to investigate phenomena associated with a high-pressure melt ejection (HPME) reactor accident sequence resulting in direct containment heating (DCH). These experiments were performed using the same experimental apparatus with identical initial conditions, except that the Surtsey test vessel contained air in DCH-3 and argon in DCH-4. Inerting the vessel with argon eliminated chemical reactions between metallic debris and oxygen. Thus, a comparison of the pressure response in DCH-3 and DCH-4 gave an indication of the DCH contribution due to metal/oxygen reactions. 44 refs., 110 figs., 43 tabs.

  17. Method of transferring regular shaped vessel into cell

    International Nuclear Information System (INIS)

    Murai, Tsunehiko.

    1997-01-01

    The present invention concerns a method of transferring regular shaped vessels from a non-contaminated area to a contaminated cell. A passage hole for allowing the regular shaped vessels to pass in the longitudinal direction is formed to a partitioning wall at the bottom of the contaminated cell. A plurality of regular shaped vessel are stacked in multiple stages in a vertical direction from the non-contaminated area present below the passage hole, allowed to pass while being urged and transferred successively into the contaminated cell. As a result, since they are transferred while substantially closing the passage hole by the regular shaped vessels, radiation rays or contaminated materials are prevented from discharging from the contaminated cell to the non-contaminated area. Since there is no requirement to open/close an isolation door frequently, the workability upon transfer can be improved remarkably. In addition, the sealing member for sealing the gap between the regular shaped vessel passing through the passage hole and the partitioning wall of the bottom is disposed to the passage hole, the contaminated materials in the contaminated cells can be prevented from discharging from the gap to the non-contaminated area. (N.H.)

  18. Integrating forensic anthropology into Disaster Victim Identification.

    Science.gov (United States)

    Mundorff, Amy Z

    2012-06-01

    This paper will provide mass fatality emergency planners, police, medical examiners, coroners and other Disaster Victim Identification (DVI) personnel ways to integrate forensic anthropologists into DVI operations and demonstrate how anthropological contributions have improved DVI projects. In mass disaster situations, anthropologists have traditionally been limited to developing biological profiles from skeletal remains. Over the past decade, however, anthropologists' involvement in DVI has extended well beyond this traditional role as they have taken on increasingly diverse tasks and responsibilities. Anthropological involvement in DVI operations is often dictated by an incident's specific characteristics, particularly events involving extensive fragmentation, commingling, or other forms of compromised remains. This paper will provide examples from recent DVI incidents to illustrate the operational utility of anthropologists in the DVI context. The points where it is most beneficial to integrate anthropologists into the DVI process include: (1) during recovery at the disaster scene; (2) at the triage station as remains are brought into the mortuary; and (3) in conducting the reconciliation process. Particular attention will be paid to quality control and quality assurance measures anthropologists have developed and implemented for DVI projects. Overall, this paper will explain how anthropological expertise can be used to increase accuracy in DVI while reducing the project's cost and duration.

  19. Radioactivity concentration measuring device for radiation waste containing vessel

    International Nuclear Information System (INIS)

    Goto, Tetsuo.

    1994-01-01

    The device of the present invention can precisely and accurately measure a radioactive concentration of radioactive wastes irrespective of the radioactivity concentration distribution. Namely, a Ge detector having a collimator and a plurality of radiation detectors are placed at the outside of the radioactive waste containing vessel in such a way that it can rotate and move vertically relative to the vessel. The plurality of radiation detectors detect radiation coefficient signals at an assumed segment unit of a predetermined length in vertical direction and for every predetermined angle unit in the rotational direction. A weight measuring device determines the weight of the vessel. A computer calculates an average density of radioactivity for the region filled with radioactivity based on the determined net weight and radiation coefficient signals assuming that the volume of the radioactivity is constant. In addition, the computer calculates the amount of radioactivity in the assumed segment by conducting γ -ray absorption compensation calculation for the material in the vessel. Each of the amount of radioactivity is integrated to determine the amount of radioactivity in the vessel. (I.S.)

  20. Nuclear reactor vessel fuel thermal insulating barrier

    Science.gov (United States)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  1. Spent nuclear fuel assembly storage vessel

    International Nuclear Information System (INIS)

    Yagishita, Takuya

    1998-01-01

    The vessel of the present invention promotes an effect of removing after heat of spent nuclear fuel assemblies so as not to give force to the storage vessel caused by expansion of heat removing partitioning plates. Namely, the vessel of the present invention comprises a cylinder body having closed upper and lower portions and a plurality of heat removing partitioning cylinders disposed each at a predetermined interval in the circumferential direction of the above-mentioned cylinder body. The heat removing partitioning cylinders comprises (1) first heat removing partitioning plates extended in the radial direction of the cylinder body and opposed at a predetermined gap in the circumferential direction of the cylinder body, and having the base ends on the side of the inner wall of the cylinder body being secured to the inner wall of the cylinder body and (2) a second heat removing plate for connecting the top ends of both opposed heat removing partitioning plates on the central side of the cylinder body with each other. Spent nuclear fuel assemblies are contained in a plurality of closed spaces surrounded by the first heat removing partitioning plates and the second heat removing partitioning plate. With such constitution, since after heat is partially transferred from the heat removing partitioning plates to the cylindrical body directly by heat conduction, the heat removing effect can be promoted compared with the prior art. (I.S.)

  2. Sealing method and sealing device for radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishiwatari, Koji; Otsuki, Akira

    1998-01-01

    A radioactive waste-containing body is hoisted down into a strong-material vessel opened upwardly, and a strong-material lid is hoisted down to the opening of the strong-material-vessel and welded. The strong material vessel is hoisted up and loaded on a corrosion resistant-material bottom plate placed horizontally. A corrosion resistant-material vessel having one opening end and having a corrosion resistant-material flange on the other end and previously agreed with the strong material-vessel main body is hoisted up by a hoisting device having an inserting device so that the opening of the corrosion resistant vessel is directed downwardly. The corrosion resistant vessel is press-fitted to the outside of the strong material-vessel by the inserting device while being heated by a preheater to shrink. Subsequently, the lower end of the corrosion resistant-material vessel and the corrosion resistant-material bottom plate are welded to constitute a corrosion resistant-material vessel. Then, the radioactive waste containing body can be sealed in a sealing vessel comprising the strong-material vessel and the corrosion resistant-material vessel. (N.H.)

  3. Test results on direct containment heating by high-pressure melt ejection into the Surtsey vessel: The TDS test series

    International Nuclear Information System (INIS)

    Allen, M.D.; Blanchat, T.K.; Pilch, M.M.

    1994-08-01

    The Technology Development and Scoping (TDS) test series was conducted to test and develop instrumentation and procedures for performing steam-driven, high-pressure melt ejection (HPME) experiments at the Surtsey Test Facility to investigate direct containment heating (DCH). Seven experiments, designated TDS-1 through TDS-7, were performed in this test series. These experiments were conducted using similar initial conditions; the primary variable was the initial pressure in the Surtsey vessel. All experiments in this test series were performed with a steam driving gas pressure of ≅ 4 MPa, 80 kg of lumina/iron/chromium thermite melt simulant, an initial hole diameter of 4.8 cm (which ablated to a final hole diameter of ≅ 6 cm), and a 1/10th linear scale model of the Surry reactor cavity. The Surtsey vessel was purged with argon ( 2 ) to limit the recombination of hydrogen and oxygen, and gas grab samples were taken to measure the amount of hydrogen produced

  4. Development of FB-MultiPier dynamic vessel-collision analysis models, phase 2 : [summary].

    Science.gov (United States)

    2014-07-01

    When collisions between large vessels and bridge : supports occur, they can result in significant : damage to bridge and vessel. These collisions : are extremely hazardous, often taking lives on : the vessel and the bridge. Direct costs of repair : a...

  5. Fuel-coolant interaction visualization test for in-vessel corium retention external reactor vessel cooling (IVR-ERVC) condition

    Energy Technology Data Exchange (ETDEWEB)

    Na, Young Su; Hong, Seong Ho; Song, Jin Ho; Hong, Seong Wan [Severe Accident and PHWR Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    A visualization test of the fuel-coolant interaction in the Test for Real cOrium Interaction with water (TROI) test facility was carried out. To experimentally simulate the In-Vessel corium Retention (IVR)- External Reactor Vessel Cooling (ERVC) conditions, prototypic corium was released directly into the coolant water without a free fall in a gas phase before making contact with the coolant. Corium (34.39 kg) consisting of uranium oxide and zirconium oxide with a weight ratio of 8:2 was superheated, and 22.54 kg of the 34.39 kg corium was passed through water contained in a transparent interaction vessel. An image of the corium jet behavior in the coolant was taken by a high-speed camera every millisecond. Thermocouple junctions installed in the vertical direction of the coolant were cut sequentially by the falling corium jet. It was clearly observed that the visualization image of the corium jet taken during the fuel-coolant interaction corresponded with the temperature variations in the direction of the falling melt. The corium penetrated through the coolant, and the jet leading edge velocity was 2.0 m/s. Debris smaller than 1 mm was 15% of the total weight of the debris collected after a fuel-coolant interaction test, and the mass median diameter was 2.9 mm.

  6. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  7. Blood Vessels in Allotransplantation.

    Science.gov (United States)

    Abrahimi, P; Liu, R; Pober, J S

    2015-07-01

    Human vascularized allografts are perfused through blood vessels composed of cells (endothelium, pericytes, and smooth muscle cells) that remain largely of graft origin and are thus subject to host alloimmune responses. Graft vessels must be healthy to maintain homeostatic functions including control of perfusion, maintenance of permselectivity, prevention of thrombosis, and participation in immune surveillance. Vascular cell injury can cause dysfunction that interferes with these processes. Graft vascular cells can be activated by mediators of innate and adaptive immunity to participate in graft inflammation contributing to both ischemia/reperfusion injury and allograft rejection. Different forms of rejection may affect graft vessels in different ways, ranging from thrombosis and neutrophilic inflammation in hyperacute rejection, to endothelialitis/intimal arteritis and fibrinoid necrosis in acute cell-mediated or antibody-mediated rejection, respectively, and to diffuse luminal stenosis in chronic rejection. While some current therapies targeting the host immune system do affect graft vascular cells, direct targeting of the graft vasculature may create new opportunities for preventing allograft injury and loss. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  8. 47 CFR Appendix - Technical Appendix 2

    Science.gov (United States)

    2010-10-01

    .... Outputs (General) S-Video Digital Video Interface (DVI);Component video (YPbPr); High-Definition... and other existing video and audio equipmentRemote control may have dedicated keys to provide direct...

  9. Polymer-based blood vessel models with micro-temperature sensors in EVE

    Science.gov (United States)

    Mizoshiri, Mizue; Ito, Yasuaki; Hayakawa, Takeshi; Maruyama, Hisataka; Sakurai, Junpei; Ikeda, Seiichi; Arai, Fumihito; Hata, Seiichi

    2017-04-01

    Cu-based micro-temperature sensors were directly fabricated on poly(dimethylsiloxane) (PDMS) blood vessel models in EVE using a combined process of spray coating and femtosecond laser reduction of CuO nanoparticles. CuO nanoparticle solution coated on a PDMS blood vessel model are thermally reduced and sintered by focused femtosecond laser pulses in atmosphere to write the sensors. After removing the non-irradiated CuO nanoparticles, Cu-based microtemperature sensors are formed. The sensors are thermistor-type ones whose temperature dependences of the resistance are used for measuring temperature inside the blood vessel model. This fabrication technique is useful for direct-writing of Cu-based microsensors and actuators on arbitrary nonplanar substrates.

  10. Diffuse vascular injury in fatal road traffic accident victims: its relationship to diffuse axonal injury.

    Science.gov (United States)

    Pittella, José E H; Gusmão, Sebastião N S

    2003-05-01

    The authors have reported a macro- and microscopic study of brain lesions in 120 victims of fatal road traffic accidents, independent of the survival time. Diffuse vascular injury (DVI) was found in 14 patients (11.7%). All patients with DVI died within 24 h after the accident. The 14 patients with DVI also showed severe (Grade 2 or 3) diffuse axonal injury (DAI). Since DVI is restricted to road traffic accidents and incompatible with life, the high frequency observed in our series could be explained by the fact that all 120 patients were victims of road traffic accidents, and 69.2% had died within 24 h after the accident. The association between DVI and severe DAI (Grades 2 and 3) suggests that both lesions depend on the same mechanism, with the degree of axonal and vascular damage being determined by the intensity of the head acceleration. Our results show a relationship between DVI and DAI that suggest there may be a spectrum or at least a continuum between these entities as distinct from DVI being a separate entity.

  11. Ex-vessel boiling experiments: laboratory- and reactor-scale testing of the flooded cavity concept for in-vessel core retention. Pt. II. Reactor-scale boiling experiments of the flooded cavity concept for in-vessel core retention

    International Nuclear Information System (INIS)

    Chu, T.Y.; Bentz, J.H.; Slezak, S.E.; Pasedag, W.F.

    1997-01-01

    For pt.I see ibid., p.77-88 (1997). This paper summarizes the results of a reactor-scale ex-vessel boiling experiment for assessing the flooded cavity design of the heavy water new production reactor. The simulated reactor vessel has a cylindrical diameter of 3.7 m and a torispherical bottom head. Boiling outside the reactor vessel was found to be subcooled nucleate boiling. The subcooling mainly results from the gravity head, which in turn results from flooding the side of the reactor vessel. The boiling process exhibits a cyclic pattern with four distinct phases: direct liquid-solid contact, bubble nucleation and growth, coalescence, and vapor mass dispersion. The results show that, under prototypic heat load and heat flux distributions, the flooded cavity will be effective for in-vessel core retention in the heavy water new production reactor. The results also demonstrate that the heat dissipation requirement for in-vessel core retention, for the central region of the lower head of an AP-600 advanced light water reactor, can be met with the flooded cavity design. (orig.)

  12. Primo vessel inside a lymph vessel emerging from a cancer tissue.

    Science.gov (United States)

    Lee, Sungwoo; Ryu, Yeonhee; Cha, Jinmyung; Lee, Jin-Kyu; Soh, Kwang-Sup; Kim, Sungchul; Lim, Jaekwan

    2012-10-01

    Primo vessels were observed inside the lymph vessels near the caudal vena cava of a rabbit and a rat and in the thoracic lymph duct of a mouse. In the current work we found a primo vessel inside the lymph vessel that came out from the tumor tissue of a mouse. A cancer model of a nude mouse was made with human lung cancer cell line NCI-H460. We injected fluorescent nanoparticles into the xenografted tumor tissue and studied their flow in blood, lymph, and primo vessels. Fluorescent nanoparticles flowed through the blood vessels quickly in few minutes, and but slowly in the lymph vessels. The bright fluorescent signals of nanoparticles disappeared within one hour in the blood vessels but remained much longer up to several hours in the case of lymph vessels. We found an exceptional case of lymph vessels that remained bright with fluorescence up to 24 hours. After detailed examination we found that the bright fluorescence was due to a putative primo vessel inside the lymph vessel. This rare observation is consistent with Bong-Han Kim's claim on the presence of a primo vascular system in lymph vessels. It provides a significant suggestion on the cancer metastasis through primo vessels and lymph vessels. Copyright © 2012. Published by Elsevier B.V.

  13. Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency

    Science.gov (United States)

    Langhoff, Ralf; Rocha-Singh, Krishna J.; Jaff, Michael R.; Blessing, Erwin; Amann-Vesti, Beatrice; Krzanowski, Marek; Peeters, Patrick; Scheinert, Dierk; Torsello, Giovanni; Sixt, Sebastian; Tepe, Gunnar

    2017-01-01

    Background— Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. Methods and Results— DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency—A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB (P=0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P=0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB (P=0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB (P=0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB (P=0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB (P=0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB (P=0.86). Conclusions— DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. Clinical Trial Registration— http

  14. Investigation of residual stresses in thick-walled vessels with combination of autofrettage and wire-winding

    International Nuclear Information System (INIS)

    Sedighi, M.; Jabbari, A.H.

    2013-01-01

    Wire-winding and autofrettage processes can be used to introduce beneficial residual stress in the cylinder of thick-walled pressure vessels. In both techniques, internal residual compressive stress will increase internal pressure capacity, improve fatigue life and reduce fatigue crack initiation. The purpose of this paper is to analyze the effects of wire-winding on an autofrettaged thick-walled vessel. Direct method which is a modified Variable Material Properties (VMP) method has been used in order to calculate residual stresses in an autofrettaged vessel. Since wire-winding is done after autofrettage process, the tangent and/or Young's modulus could be changed. For this reason, a new wire-winding method based on Direct Method is introduced. The obtained results for wire-wound autofrettaged vessels are validated by finite element method. The results show that by using this approach, the residual hoop stresses in a wire-wound autofrettaged vessel have a more desirable distribution in the cylinder. -- Highlights: • Combination of autofrettage and wire-winding in pressure vessels has been presented. • A new method based on Direct method is presented for wire-winding process. • Residual hoop stresses are compared in vessels cylinders for different cases. • The residual hoop stress has a more desirable stress distribution. • The benefits of the combined vessel are highlighted in comparison with single cases

  15. Welding distortion control in double walled KSTAR vacuum vessel fabrication

    International Nuclear Information System (INIS)

    Oh, D. W.; Lee, G. T.; Kim, H. K.; Yang, H. L.; Bak, J. S.

    2004-01-01

    The KSTAR(Korea Superconducting Tokamak Advanced Research) vacuum vessel is designed to be a double walled structure made of 12mm thick 316LN stainless steel with a D shaped cross-section about 4 m height. Vacuum vessel was pre-fabricated in two parts, 180 degree and 157.5 degree sectors in toroidal direction to meet the transportation purpose. These two parts have to be welded on site with ±2mm allowable fabrication tolerances. 1/3 scaled mock-up model was used to estimate the welding distortion and to ensure the weld quality of vacuum vessel. Gas Tungsten Arc Welding(GTAW), which has been approved by procedure qualification test, was used during mock-up test and vacuum vessel site fabrication. Welding distortion could be managed by allowing for distortion in opposite direction, by applying high restraint using lots of strong backs, by controlling the welding heat input with symmetrical welding sequence. The integrity of the site welding joint was assured by radiographic test, ultrasonic test and leak test with helium detecting method

  16. A service laboratory's view of the status and direction of reactor vessel surveillance

    International Nuclear Information System (INIS)

    Norris, E.B.

    1981-01-01

    Advances in testing techniques and analysis procedures have had a minor impact to date on the conduct of reactor vessel material surveillance programs. However, major thrusts in the near future will be associated with the development of elastic-plastic fracture toughness data on irradiated materials and improvements in analysis techniques for projecting surveillance results to the pressure vessel wall. In this regard, increased emphasis will be placed on the development of R-curves from the results of J-integral tests. Also, efforts will be increased to develop a better understanding of neutron irradiation embrittlement mechanisms, to determine if a time dependency of damage can lead to saturation and to evaluate the significance of small variations in irradiation temperature on the embrittlement response

  17. Containment vessel construction for nuclear power reactors

    International Nuclear Information System (INIS)

    Sulzer, H.D.; Coletti, J.L.

    1975-01-01

    A nuclear containment vessel houses an inner reactor housing structure whose outer wall is closely spaced from the inner wall of the containment vessel. The inner reactor housing structure is divided by an intermediate floor providing an upper chamber for housing the reactor and associated steam generators and a lower chamber directly therebeneath containing a pressure suppression pool. Communication between the upper chamber and the pressure suppression pool is established by conduits extending through the intermediate floor which terminate beneath the level of the pressure suppression pool and by inlet openings in the reactor housing wall beneath the level of the pressure suppression pool which communicate with the annulus formed between the outer wall of the reactor housing structure and the inner wall of the containment vessel. (Official Gazette)

  18. Direct in-vessel applications experiments at Harvard Air Cleaning Laboratory. Annual report, October 1, 1975--January 31, 1977

    International Nuclear Information System (INIS)

    Mallove, E.; Hinds, W.; First, M.W.

    1977-02-01

    Prototypes of direct in-vessel emergency air cleaning systems were evaluated for possible application in an LMFBR containment vessel after a hypothetical core disruptive accident. These were turbulence enhanced sedimentation, powder dispersal scavenging, acoustic agglomeration enhanced sedimentation, and combinations of turbulence with powder dispersal. The effect of turbulent agglomeration in enhancing the sedimentation of a sodum pool fire aerosol was experimentally demonstrated in a 90 m 3 test chamber, 4 meters high. Two hour dose reduction factors (DRF(2 hr)) from 7 to 56 were achieved in the 4 meter high chamber using fan-induced turbulent agglomeration on aerosols that varied in initial mass concentration from 1 to 12 gm/m 3 . In the same chamber, a prototype limestone powder dispersal scavenging system was tested and achieved DRF(2 hr)'s up to 10. The beneficial effect of combining turbulence with powder dispersal in a single system was demonstrated in a test which yielded a DRF(2 hr) of 20. This was greater than for either mechanism separately applied when initial aerosol mass concentration was 2 gm/m3. Acoustic agglomeration of sodium pool fire aerosols was tested in a smaller 0.65 m 3 , 75 cm high settling chamber, using an electronic siren which produced a sound pressure level of 145 dB in the reverberant chamber. The DRF(2 hr) in the small chamber with the siren operating was found to be from 17 to 31, 2 to 3 times greater than the DRF(2 hr) for unperturbed settling. Pulse-jet engines were found to be unsuitable for generating high sound levels for this application. Scaling each of the systems tested to a 30 m high containment vessel indicated no reason why one or more of the systems investigated could not be applied successfully as an emergency air cleaning system

  19. Intraabdominal laparoscopy-assisted "open" vessel ligation of testicular vessels: a potential treatment for varicocele.

    Science.gov (United States)

    Miyano, Go; Miyahara, Katsumi; Halibieke, Abudebieke; Lane, Geoffrey J; Okazaki, Tadaharu; Yamataka, Atsuyuki

    2011-10-01

    We tested our laparoscopy-assisted "open" ligation (LOL) technique on testicular vessels. We ligated the left testicular artery and vein (TAV) in 8-week-old male Wister rats using LOL (LOL group; n=10) or laparotomy (open group; n=10). In LOL, a 0-degree laparoscope was introduced through a 5-mm epigastric trocar. A 3-mm grasper was used to expose the left TAV. A lapa-her-closure (LHC) needle loaded with 3-0 SurgiPro was directly inserted into the left lower quadrant where the left TAV should be and advanced under the vessels, and the suture material was released leaving one end outside. The LHC was then withdrawn a little and advanced again over the vessels to grasp the end of the suture material just released to bring it outside. This was proximally repeated. The two ends of both sutures were conventionally tied outside, and the knot was passed through the insertion site and tightened around the vessels. In the open group, the left TAV were ligated using two 3-0 SurgiPro ties. In both groups, the right side was left intact. All rats were sacrificed 2 weeks postoperatively, and both testes were examined with hematoxylin and eosin. Treatment time was 5-7 minutes for LOL and 7-8 minutes for the open group. Postoperative recovery was uneventful. No adhesions were present between the ligated vessels and bowel in any rat. Histopathology of all left testes showed coagulative necrosis of germinal cells and seminiferous tubules; all right testes were normal. LOL appears to be as effective as open ligation and may find application for treating varicocele.

  20. Fundamentals of Electrical Propulsion Plant Design,

    Science.gov (United States)

    1982-04-06

    contacts DVI and DV2 close the indicator light LS2 and L53 circuits. Electric Fan starter n. r. contacts DVl and DY2 close the red indicator light...forward rotation, /. corresponding tD vessel movement i///’,/iI X,, /;/forward; ’ are curves of GED -tJ ’ !’ i ’ " f \\ \\ ’ . . L---,torques after reversal...Calculation based on generator static characteristics, i. e., based on parameters Xd and Td , are linked with the most difficult GED operating conditions

  1. Experimental observation of a multi-dimensional mixing behavior of steam-water flow in the MIDAS test facility

    International Nuclear Information System (INIS)

    Kweon, T. S.; Yun, B. J.; Ah, D. J.; Ju, I. C.; Song, C. H.; Park, J. K.

    2001-01-01

    Multi-dimensional thermal-hydraulic hehavior, such as ECC (Emergency Core Cooling) bypass, ECC penetration, steam-water condensation and accumulated water level, in an annular downcomer of a PWR (Pressurized Water Reactor) reactor vessel with a DVI(Direct Vessel Injection) injection mode is presented based on the experimental observations in the MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) steam-water facility. From the steady-state tests to similate a late reflood phase of LBLOCA (Large Break Loss-of-Coolant Accidents), major thermal-hydraulic phenomena in the downcomer are quantified under a wide range of test conditions. Especially, isothermal lines show well multi-dimensional phenomena of phase interaction between steam and water in the annulus downcomer. Overall test results show that multi-dimensional thermal-hydraulic behaviors occur in the downcomer annulus region as expected. The MIDAS test facility is a steam-water separate effect test facility, which is 1/4.93 linearly scaled-down of a 1400 MWe PWR type of nuclear reactor, with focusing on understanding multi-dimensional thermal-hydraulic phenomena in annulus downcomer with various types of safety injection location during refill or reflood phase of a LBLOCA in PWR

  2. Seismic transient analysis of a containment vessel with penetrations

    International Nuclear Information System (INIS)

    Dahlke, H.J.; Weiner, E.O.

    1979-12-01

    A linear transient analysis of the FFTF containment vessel was conducted with STAGS to justify the load levels used for the seismic qualification testing of the heating and ventiliation valve operators. The modeling consists of a thin axisymmetric shell for the containment vessel with four penetrations characterized by linear and rotational inertias as well as attachment characteristics to the shell. Motions considered are horizontal, rocking and vertical input to the base, and the solution is carried out by direct integration. Results show that the test levels and the approximate analyses considered are conservative. Response spectra for some containment vessel penetrations applicable to the model are presented

  3. Inter-vessels in-service inspection of Super-Phenix

    International Nuclear Information System (INIS)

    Asty, M.; Saglio, R.; Viard, J.; Lerat, B.

    1984-01-01

    The vessels design of fast breeder reactor Super-Phenix enables inspection during operating time. A self-moving machine -MIR- has been built up especially for that purpose. It is able to carry out visual and ultrasonorous inspection. MIR structure is that of a tetrahedron, all tops of which are fitted with two wheels, as for traction and direction. The wheels are leaning on booth the two vessels. Thanks to a computer-assisted control system, MIR is able to move along in every part of the inter-vessels space. Studies have been carried on at the French Commissariat a l'Energie Atomique, by two Sections of the advanced technologies Service. After outlining MIR working conditions, its main characteristics are described [fr

  4. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae

    2016-01-01

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study

  5. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae [KEPCO Engineering and Construction Co. Ltd., Deajeon (Korea, Republic of)

    2016-10-15

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study.

  6. Magnetic Barkhausen noise and magneto acoustic emission in pressure vessel steel

    Energy Technology Data Exchange (ETDEWEB)

    Neyra Astudillo, Miriam Rocío, E-mail: neyra@cnea.gov.ar [IT Sabato, Universidad Nacional de San Martín, UNSAM, Av. General Paz 1499, Buenos Aires (Argentina); Universidad Tecnológica Nacional UTN, Regional Delta, Buenos Aires (Argentina); López Pumarega, María Isabel, E-mail: lopezpum@cnea.gov.ar [Comisión Nacional de Energía Atómica, CNEA, Av. General Paz 1499, Buenos Aires (Argentina); Núñez, Nicolás Marcelo, E-mail: nnunez@cnea.gov.ar [Comisión Nacional de Energía Atómica, CNEA, Av. General Paz 1499, Buenos Aires (Argentina); Pochettino, Alberto, E-mail: alberto.poch@gmail.com [Comisión Nacional de Energía Atómica, CNEA, Av. General Paz 1499, Buenos Aires (Argentina); Instituto de Investigación e Ingeniería Ambiental (3iA), Campus Miguelete, UNSAM, Av. 25 de Mayo y Francia, 1650 San Martín Argentina (Argentina); Ruzzante, José, E-mail: ruzzante@gmail.com [Universidad Tecnológica Nacional UTN, Regional Delta, Buenos Aires (Argentina); Universidad Nacional de Tres de Febrero UNTREF, Caseros, Buenos Aires (Argentina); Universidad Nacional de Chilecito, UNdeC, La Rioja (Argentina)

    2017-03-15

    Magnetic Barkhausen Noise (MBN) and Magneto Acoustic Emission (MAE) were studied in A508 Class II forged steel used for pressure vessels in nuclear power stations. The magnetic experimental determinations were completed with a macro graphic study of sulfides and the texture analysis of the material. The analysis of these results allows us to determine connections between the magnetic anisotropy, texture and microstructure of the material. Results clearly suggest that the plastic flow direction is different from the forging direction indicated by the material supplier - Highlights: • MBN and MAE studied in nuclear power pressure vessel steel. • Comparison with macro graphic study of sulfides and texture analysis of the material. • Connections with magnetic anisotropy, texture and microstructure of material. • Plastic flow direction different from the forging direction indicated.

  7. Magnetic Barkhausen noise and magneto acoustic emission in pressure vessel steel

    International Nuclear Information System (INIS)

    Neyra Astudillo, Miriam Rocío; López Pumarega, María Isabel; Núñez, Nicolás Marcelo; Pochettino, Alberto; Ruzzante, José

    2017-01-01

    Magnetic Barkhausen Noise (MBN) and Magneto Acoustic Emission (MAE) were studied in A508 Class II forged steel used for pressure vessels in nuclear power stations. The magnetic experimental determinations were completed with a macro graphic study of sulfides and the texture analysis of the material. The analysis of these results allows us to determine connections between the magnetic anisotropy, texture and microstructure of the material. Results clearly suggest that the plastic flow direction is different from the forging direction indicated by the material supplier - Highlights: • MBN and MAE studied in nuclear power pressure vessel steel. • Comparison with macro graphic study of sulfides and texture analysis of the material. • Connections with magnetic anisotropy, texture and microstructure of material. • Plastic flow direction different from the forging direction indicated.

  8. Mass optimization of a small pressure vessel using metal/FRP (fiber reinforced polymers) hybrid structures

    International Nuclear Information System (INIS)

    Nisar, J.A.; Abdullah, A.N.; Iqbal, N.

    2004-01-01

    In hybrid pressure vessels, composite (Fiber) is wound over a metallic liner (Steel/Aluminum) in hoop direction. In this concept of hybrid pressure vessel structure, metallic liner takes all the axial loads and fiber reinforced polymers (FRP/sub s/) takes load in circumferential (Hoop) direction. Hybrid structures combine the relatively high shear stiffness and ductility of metal alloy with high specific stiffness, strength and fatigue properties of FRP/sub s/. The relatively simple methods for producing hybrid structures circumvent the need for the complex and expensive equipment that is used for advanced composites processing. This paper presents an efficient way of designing a hybrid pressure vessel where prime concern is weight reduction over an equivalent aluminum structure and investigates various methodologies regarding combinations of metals and FRP/sub s/ for optimization of a given pressure vessel. For this purpose we adopted two different methods of simulation one is computer simulation using ANSYS and other is experimental verification by hydrostatic testing of manufactured pressure vessel. Two different pressure vessels one with aluminum liner and other with steel liner were fabricated. Kevlar 49/epoxy was wrapped around the liners in hoop direction. Both the pressure vessels were put into hydrostatic test. Strains were measured during the test and then converted into corresponding stresses. Results of hydrostatic test were quite in favor of the ANSYS results. In this way we have successfully designed, manufactured and tested the Hybrid pressure vessel saving almost 40% weight in case of aluminum liner and 43.6% in case of steel liner. (author)

  9. Multiple shell pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.

    1988-01-01

    A method is described of fabricating a pressure vessel comprising the steps of: attaching a first inner pressure vessel having means defining inlet and outlet openings to a top flange, placing a second inner pressure vessel, having means defining inlet and outlet opening, concentric with and spaced about the first inner pressure vessel and attaching the second inner pressure vessel to the top flange, placing an outer pressure vessel, having inlet and outlet openings, concentric with and spaced apart about the second inner pressure vessel and attaching the outer pressure vessel to the top flange, attaching a generally cylindrical inner inlet conduit and a generally cylindrical inner outlet conduit respectively to the inlet and outlet openings in the first inner pressure vessel, attaching a generally cylindrical outer inlet conduit and a generally cylindrical outer outlet conduit respectively to the inlet and outlet opening in the second inner pressure vessel, heating the assembled pressure vessel to a temperature above the melting point of a material selected from the group, lead, tin, antimony, bismuth, potassium, sodium, boron and mixtures thereof, filling the space between the first inner pressure vessel and the second inner pressure vessel with material selected from the group, filling the space between the second inner pressure vessel and the outer pressure vessel with material selected from the group, and pressurizing the material filling the spaces between the pressure vessels to a predetermined pressure, the step comprising: pressurizing the spaces to a pressure whereby the wall of the first inner pressure vessel is maintained in compression during steady state operation of the pressure vessel

  10. Investigation of vertical liquid film width upon impingement on flat plate

    International Nuclear Information System (INIS)

    Kim, Won J.; Son, Hyung M.; Suh, Kune Y.

    2003-01-01

    In the early, high pressure phase during a Large-Break Loss-Of-Coolant Accident (LBLOCA), the Emergency Core Cooling (ECC) water of the Direct Vessel Injection (DVI) system is supplied from the Safety Injection Tank (SIT). After the shortage of the SIT, the In-containment Refueling Water Storage Tank (IRWST) supplies water to the safety system. Velocity of the injection flow varies during the process from the initial value of over 10 m/s in the blowdown phase to 2∼3 m/s in the later phase of reflood. During the safety injection, such important phenomena are observed as impingement, bypass, entrainment and sweepout, and condensation. The impingement is referred to the case where the ECC water is injected to strike on the reactor inner vessel. Accordingly, the water generates a liquid film to form a ridge on the wall. The liquid film then flows down the wall due to gravity. This impingement is interrupted by the steam-water mixture bypass flow to the break. The bypass, in turn, is affected by the impingement. This study is intended to understand the impinged water flow behavior neglecting such secondary effects as the temperature-dependent thermodynamic properties and the reactor vessel curvature. An emphasis is put on interpreting the results of visual inspection to understand the underlying mechanism of rather complex turbulent flow in the downcomer

  11. Design of High Temperature Reactor Vessel Using ANSYS Software

    International Nuclear Information System (INIS)

    Bandriyana; Kasmudin

    2003-01-01

    Design calculation and evaluation of material strength for high temperature reactor vessel based on the design of HTR-10 high temperature reactor vessel were carried out by using the ANSYS 5.4 software. ANSYS software was applied to calculate the combined load from thermal and pressure load. Evaluation of material strength was performed by calculate and determine the distribution of temperature, stress and strain in the thickness direction of vessel, and compared with its material strength for designed. The calculation was based on the inner wall temperature of vessel of 600 o C and the outer temperature of 500 and 600 o C. Result of calculation gave the maximum stress for outer temperature of 600 o C was 288 N/ mm 2 and strain of 0.000187. For outer temperature of 500 o C the maximum stress was 576 N/ mm 2 and strain of 0.003. Based on the analysis result, the material of steel SA 516-70 with limited stress for design of 308 N/ mm 2 can be used for vessel material with outer wall temperature of 600 o C

  12. A DYNAMIC VALGUS INDEX THAT COMBINES HIP AND KNEE ANGLES: ASSESSMENT OF UTILITY IN FEMALES WITH PATELLOFEMORAL PAIN.

    Science.gov (United States)

    Scholtes, Sara A; Salsich, Gretchen B

    2017-06-01

    Two=dimensional motion analysis of lower=extremity movement typically focuses on the knee frontal plane projection angle, which considers the position of the femur and the tibia. A measure that includes the pelvis may provide a more comprehensive and accurate indicator of lower=extremity movement. Hypothesis/Purpose: The purpose of the study was to describe the utility of a two=dimensional dynamic valgus index (DVI) in females with patellofemoral pain. The hypothesis was that the DVI would be more reliable and valid than the knee frontal plane projection angle, be greater in females with patellofemoral pain during a single=limb squat than in females without patellofemoral pain, and decrease in females with patellofemoral pain following instruction. Study Design: Controlled Laboratory Study. Data were captured while participants performed single limb squats under two conditions: usual and corrected. Two=dimensional hip and knee angles and a DVI that combined the hip and knee angles were calculated. Three=dimensional sagittal, frontal, and transverse plane angles of the hip and knee and a DVI combining the frontal and transverse plane angles were calculated. The two=dimensional DVI demonstrated moderate reliability (ICC=0.74). The correlation between the two=dimensional and three=dimensional DVI's was 0.635 (ppatellofemoral pain demonstrated a greater two=dimensional DVI (31.14 °±13.36 °) than females without patellofemoral pain (18.30 °±14.97 °; p=0.010). Females with patellofemoral pain demonstrated a decreased DVI in the corrected (19.04 °±13.70 °) versus usual (31.14 °±13.36 °) condition (p=0.001). The DVI is a reliable and valid measure that may provide a more comprehensive assessment of lower=extremity movement patterns than the knee frontal plane projection angle in individuals with lower=extremity musculoskeletal pain problems. 2b.

  13. 33 CFR 90.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INLAND NAVIGATION RULES INLAND RULES: INTERPRETATIVE RULES § 90.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the Inland Rules states that when a pushing vessel and...

  14. 33 CFR 82.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES 72 COLREGS: INTERPRETATIVE RULES § 82.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the 72 COLREGS states that when a pushing vessel and a...

  15. Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis

    International Nuclear Information System (INIS)

    Spuentrup, Elmar; Botnar, Rene M.

    2006-01-01

    Coronary magnetic resonance (MR) imaging has dramatically emerged over the last decade. Technical improvements have enabled reliable visualization of the proximal and midportion of the coronary artery tree for exclusion of significant coronary artery disease. However, current technical developments focus also on direct visualization of the diseased coronary vessel wall and imaging of coronary plaque because plaques without stenoses are typically more vulnerable with higher risk of plaque rupture. Plaque rupture with subsequent thrombosis and vessel occlusion is the main cause of myocardial infarction. Very recently, the first success of molecular imaging in the coronary arteries has been demonstrated using a fibrin-specific contrast agent for selective visualization of coronary thrombosis. This demonstrates in general the high potential of molecular MR imaging in the field of coronary artery disease. In this review, we will address recent technical advances in coronary MR imaging, including visualization of the lumen and the vessel wall and molecular imaging of coronary arteriothrombosis. First results of these new approaches will be discussed. (orig.)

  16. Ex-vessel water-level and fission-product monitoring for LWR

    International Nuclear Information System (INIS)

    DeVolpi, A.; Markoff, D.

    1988-01-01

    Given that the need for direct measurement of reactor coolant inventory under operational or abnormal conditions remains unsatisfied, a high-energy gamma-ray detection system is described for ex-vessel monitoring. The system has been modeled to predict response in a PWR, and the model has been validated with a LOFT LOCA sequence. The apparatus, situated outside the pressure vessel, would give relative water level and density over the entire vessel height and distinguish differing levels in the downcomer and core. It would also have significant sensitivity after power shutdown because of high-energy gamma rays from photoneutron capture, the photoneutrons being the result of fission-product decay in the core. Fission-products released to the coolant and accumulated in the top of a PWR vessel would also be theoretically detectable

  17. The Analysis of the Causes of Emergencies on the Vessels

    Directory of Open Access Journals (Sweden)

    Alicja Mrozowska

    2017-12-01

    Full Text Available The article discusses the results of research conducted on the vessels, covering a wide spectrum of issues relating to the exploitation of vessels of various flags, as well as operating security and safety systems on board. The main aim of the study was to collect numbers of data directly from the crew, for examples: indicate by the crew marine areas with the greatest probability of occurrence of casualties and incidents, trying to the definition the causes of their occurrence, prevention actions used on board and analyses operating safety systems used on the various type of vessels. The analysis of research became the basis to identify strengths and weaknesses areas of the vessel operation. The author proposes a solution to be implemented on board and emphasizes meaning of safety management system.

  18. Manufacture of EAST VS In-Vessel Coil

    International Nuclear Information System (INIS)

    Long, Feng; Wu, Yu; Du, Shijun; Jin, Huan; Yu, Min; Han, Qiyang; Wan, Jiansheng; Liu, Bin; Qiao, Jingchun; Liu, Xiaochuan; Li, Chang; Cai, Denggang; Tong, Yunhua

    2013-01-01

    Highlights: • ITER like Stainless Steel Mineral Insulation Conductor (SSMIC) used for EAST Tokamak VS In-Vessel Coil manufacture first time. • Research on SSMIC fabrication was introduced in detail. • Two sets totally four single-turn VS coils were manufactured and installed in place symmetrically above and below the mid-plane in the vacuum vessel of EAST. • The manufacture and inspection of the EAST VS coil especially the joint for the SSMIC connection was described in detail. • The insulation resistances of all the VS coils have no significant reduction after endurance test. -- Abstract: In the ongoing latest update round of EAST (Experimental Advanced Superconducting Tokamak), two sets of two single-turn Vertical Stabilization (VS) coils were manufactured and installed symmetrically above and below the mid-plane in the vacuum vessel of EAST. The Stainless Steel Mineral Insulated Conductor (SSMIC) developed for ITER In-Vessel Coils (IVCs) in Institute of Plasma Physics, Chinese Academy of Science (ASIPP) was used for the EAST VS coils manufacture. Each turn poloidal field VS coil includes three internal joints in the vacuum vessel. The middle joint connects two pieces of conductor which together form an R2.3 m arc segment inside the vacuum vessel. The other two joints connect the arc segment with the two feeders near the port along the toroidal direction to bear lower electromagnetic loads during operation. Main processes and tests include material performances checking, conductor fabrication, joint connection and testing, coil forming, insulation performances measurement were described herein

  19. Muscle-splitting approach to superior and inferior gluteal vessels: versatile source of recipient vessels for free-tissue transfer to sacral, gluteal, and ischial regions.

    Science.gov (United States)

    Park, S

    2000-07-01

    The superior gluteal vessel has been reported as a recipient in free-tissue transfer for the coverage of complex soft-tissue defects in the lumbosacral region, where a suitable recipient vessel is difficult to find. The characteristics of proximity, vessel caliber, and constancy make the superior gluteal vessel preferable to previously reported recipient vessels. However, there are technical difficulties in microsurgery (e.g., short pedicle length and deep location) and muscle injury (transection of the muscle) associated with use of the superior gluteal vessel. The purpose of this article is to present a modification of an approach to the gluteal vessel to alleviate technical difficulties and minimize muscle injury. From August of 1997 to January of 1999, six patients received microvascular transfer of the latissimus dorsi muscle or myocutaneous flap to the sacral (4) and ischial (2) regions. The causes of defects were tumor (1), trauma (1), and pressure sores (4). A muscle-splitting approach was used on the superior gluteal vessel and was later applied to the inferior gluteal vessel. The gluteus maximus muscle was split as needed in the direction of its fibers, and the perforators were dissected down to the superior or inferior gluteal artery and vein deep into the muscle. The follow-up period ranged from 6 to 22 months, and all of the flaps survived with complete recovery of the lesion. The major drawbacks of using the superior and inferior gluteal vessels can be overcome with the muscle-splitting approach, which provides increased accessibility and additional length to the vascular pedicle while causing minimal injury to the muscle itself. It also proves to be an easy, safe, and reliable method of dissection. When free-tissue transfer to sacral, gluteal, and ischial regions is indicated, the muscle-splitting approach to the superior and inferior gluteal vessels is a recommended option in the selection of a recipient vessel.

  20. Interstitial Cells of Blood Vessels

    Directory of Open Access Journals (Sweden)

    Vladimír Pucovský

    2010-01-01

    Full Text Available Blood vessels are made up of several distinct cell types. Although it was originally thought that the tunica media of blood vessels was composed of a homogeneous population of fully differentiated smooth muscle cells, more recent data suggest the existence of multiple smooth muscle cell subpopulations in the vascular wall. One of the cell types contributing to this heterogeneity is the novel, irregularly shaped, noncontractile cell with thin processes, termed interstitial cell, found in the tunica media of both veins and arteries. While the principal role of interstitial cells in veins seems to be pacemaking, the role of arterial interstitial cells is less clear. This review summarises the knowledge of the functional and structural properties of vascular interstitial cells accumulated so far, offers hypotheses on their physiological role, and proposes directions for future research.

  1. Cooling of pressurized water nuclear reactor vessels

    International Nuclear Information System (INIS)

    Curet, H.D.

    1978-01-01

    The improvement of pressurized water nuclear reactor vessels comprising flow dividers providing separate and distinct passages for the flow of core coolant water from each coolant water inlet, the flow dividers being vertically disposed in the annular flow areas provided by the walls of the vessel, the thermal shield (if present), and the core barrel is described. In the event of rupture of one of the coolant water inlet lines, water, especially emergency core coolant water, in the intact lines is thus prevented from by-passing the core by circumferential flow around the outermost surface of the core barrel and is instead directed so as to flow vertically downward through the annulus area between the vessel wall and the core barrel in a more normal manner to increase the probability of cooling of the core by the available cooling water in the lower plenum, thus preventing or delaying thermal damage to the core, and providing time for other appropriate remedial or damage preventing action by the operator

  2. Processing vessel for high level radioactive wastes

    International Nuclear Information System (INIS)

    Maekawa, Hiromichi

    1998-01-01

    Upon transferring an overpack having canisters containing high level radioactive wastes sealed therein and burying it into an underground processing hole, an outer shell vessel comprising a steel plate to be fit and contained in the processing hole is formed. A bury-back layer made of dug earth and sand which had been discharged upon forming the processing hole is formed on the inner circumferential wall of the outer shell vessel. A buffer layer having a predetermined thickness is formed on the inner side of the bury-back layer, and the overpack is contained in the hollow portion surrounded by the layer. The opened upper portion of the hollow portion is covered with the buffer layer and the bury-back layer. Since the processing vessel having a shielding performance previously formed on the ground, the state of packing can be observed. In addition, since an operator can directly operates upon transportation and burying of the high level radioactive wastes, remote control is no more necessary. (T.M.)

  3. Design optimization of a thin walled pressure vessel

    International Nuclear Information System (INIS)

    Sadiq, S.

    2001-01-01

    Design evaluation of a pressure vessel is not only to build confidence on its integrity but also to reduce structural weight and enhance the performance of the structure. Pressure vessel, e.g., a rocket motor not only has to withstand the high operating temperatures but it must also be able to survive the internal pressures and external aerodynamic forces and bending stresses during its operation in flight. A research program was devised to study the stresses, which are generated in a thin walled pressure vessel during actual operation and its simulation with cold testing technique, i.e., by means of hydrostatic testing employing electrical resistance strain gauges on the external surface of the cylinder. The objective of the research was to uphold the performance of the vessel by reducing its thickness from 6.09 to 5.5 mm (which of course reduces the safety factor margin from 1.8 to 1.5); thereby curtailing the overall structural weight and maintaining the efficiency of the vessel itself during its live operation. The techniques employed were hydrostatic testing, data acquisition system for obtaining data on strains from the electrical resistance strain gauges and later employing V on Mises yield criterion empirical relation to computer the stresses in hoop and longitudinal directions. (author)

  4. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  5. Comprehending the structure of a vacuum vessel and in-vessel components of fusion machines. 1. Comprehending the vacuum vessel structure

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Nakahira, Masataka

    2006-01-01

    The functions, conditions and structure of vacuum vessel using tokamak fusion machines are explained. The structural standard and code of vacuum vessel, process of vacuum vessel design, and design of ITER vacuum vessel are described. Production and maintenance of ultra high vacuum, confinement of radioactive materials, support of machines in vessel and electromagnetic force, radiation shield, plasma vertical stability, one-turn electric resistance, high temperature baking heat and remove of nuclear heat, reduce of troidal ripple, structural standard, features of safety of nuclear fusion machines, subjects of structural standard of fusion vacuum vessel, design flow of vacuum vessel, establishment of radial build, selections of materials, baking and cooling method, basic structure, structure of special parts, shield structure, and of support structure, and example of design of structure, ITER, are stated. (S.Y.)

  6. Preliminary structural evaluations of the STAR-LM reactor vessel and the support design

    International Nuclear Information System (INIS)

    Koo, Gyeong-Hoi; Sienicki, James J.; Moisseytsev, Anton

    2007-01-01

    In this paper, preliminary structural evaluations of the reactor vessel and support design of the STAR-LM (The Secure, Transportable, Autonomous Reactor - Liquid Metal variant), which is a lead-cooled reactor, are carried out with respect to an elevated temperature design and seismic design. For an elevated temperature design, the structural integrity of a direct coolant contact to the reactor vessel is investigated by using a detail structural analysis and the ASME-NH code rules. From the results of the structural analyses and the integrity evaluations, it was found that the design concept of a direct coolant contact to the reactor vessel cannot satisfy the ASME-NH rules for a given design condition. Therefore, a design modification with regards to the thermal barrier is introduced in the STAR-LM design. For a seismic design, detailed seismic time history response analyses for a reactor vessel with a consideration of a fluid-structure interaction are carried out for both a top support type and a bottom support type. And from the results of the hydrodynamic pressure responses, an investigation of the minimum thickness design of the reactor vessel is tentatively carried out by using the ASME design rules

  7. Diaphragmatic lymphatic vessel behavior during local skeletal muscle contraction.

    Science.gov (United States)

    Moriondo, Andrea; Solari, Eleonora; Marcozzi, Cristiana; Negrini, Daniela

    2015-02-01

    The mechanism through which the stresses developed in the diaphragmatic tissue during skeletal muscle contraction sustain local lymphatic function was studied in 10 deeply anesthetized, tracheotomized adult Wistar rats whose diaphragm was exposed after thoracotomy. To evaluate the direct effect of skeletal muscle contraction on the hydraulic intraluminal lymphatic pressures (Plymph) and lymphatic vessel geometry, the maximal contraction of diaphragmatic fibers adjacent to a lymphatic vessel was elicited by injection of 9.2 nl of 1 M KCl solution among diaphragmatic fibers while Plymph was recorded through micropuncture and vessel geometry via stereomicroscopy video recording. In lymphatics oriented perpendicularly to the longitudinal axis of muscle fibers and located at skeletal muscle contraction (Dmc) decreased to 61.3 ± 1.4% of the precontraction value [resting diameter (Drest)]; however, if injection was at >900 μm from the vessel, Dmc enlarged to 131.1 ± 2.3% of Drest. In vessels parallel to muscle fibers, Dmc increased to 122.8 ± 2.9% of Drest. During contraction, Plymph decreased as much as 22.5 ± 2.6 cmH2O in all submesothelial superficial vessels, whereas it increased by 10.7 ± 5.1 cmH2O in deeper vessels running perpendicular to contracting muscle fibers. Hence, the three-dimensional arrangement of the diaphragmatic lymphatic network seems to be finalized to efficiently exploit the stresses exerted by muscle fibers during the contracting inspiratory phase to promote lymph formation in superficial submesothelial lymphatics and its further propulsion in deeper intramuscular vessels. Copyright © 2015 the American Physiological Society.

  8. Conjugate heat transfer analysis for in-vessel retention with external reactor vessel cooling

    International Nuclear Information System (INIS)

    Park, Jong-Woon; Bae, Jae-ho; Song, Hyuk-Jin

    2016-01-01

    Highlights: • A conjugate heat transfer analysis method is applied for in-vessel corium retention. • 3D heat diffusion has a formidable effect in alleviating focusing heat load from metallic layer. • The focusing heat load is decreased by about 2.5 times on the external surface. - Abstract: A conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue for in-vessel retention. The method calculates steady-state three-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel three-layered stratified corium (metallic pool, oxide pool and heavy metal and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel). The three-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method. For the ex-vessel boiling boundary conditions, nucleate, transition and film boiling are considered. The thermal integrity of a reactor vessel is addressed in terms of heat flux at the outer-most nodes of the vessel and remaining thickness profile. The vessel three-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate

  9. Probabilistic assessment of pressure vessel and piping reliability

    International Nuclear Information System (INIS)

    Sundararajan, C.

    1986-01-01

    The paper presents a critical review of the state-of-the-art in probabilistic assessment of pressure vessel and piping reliability. First the differences in assessing the reliability directly from historical failure data and indirectly by a probabilistic analysis of the failure phenomenon are discussed and the advantages and disadvantages are pointed out. The rest of the paper deals with the latter approach of reliability assessment. Methods of probabilistic reliability assessment are described and major projects where these methods are applied for pressure vessel and piping problems are discussed. An extensive list of references is provided at the end of the paper

  10. Cholinergic innervation of human mesenteric lymphatic vessels.

    Science.gov (United States)

    D'Andrea, V; Bianchi, E; Taurone, S; Mignini, F; Cavallotti, C; Artico, M

    2013-11-01

    The cholinergic neurotransmission within the human mesenteric lymphatic vessels has been poorly studied. Therefore, our aim is to analyse the cholinergic nerve fibres of lymphatic vessels using the traditional enzymatic techniques of staining, plus the biochemical modifications of acetylcholinesterase (AChE) activity. Specimens obtained from human mesenteric lymphatic vessels were subjected to the following experimental procedures: 1) drawing, cutting and staining of tissues; 2) staining of total nerve fibres; 3) enzymatic staining of cholinergic nerve fibres; 4) homogenisation of tissues; 5) biochemical amount of proteins; 6) biochemical amount of AChE activity; 6) quantitative analysis of images; 7) statistical analysis of data. The mesenteric lymphatic vessels show many AChE positive nerve fibres around their wall with an almost plexiform distribution. The incubation time was performed at 1 h (partial activity) and 6 h (total activity). Moreover, biochemical dosage of the same enzymatic activity confirms the results obtained with morphological methods. The homogenates of the studied tissues contain strong AChE activity. In our study, the lymphatic vessels appeared to contain few cholinergic nerve fibres. Therefore, it is expected that perivascular nerve stimulation stimulates cholinergic nerves innervating the mesenteric arteries to release the neurotransmitter AChE, which activates muscarinic or nicotinic receptors to modulate adrenergic neurotransmission. These results strongly suggest, that perivascular cholinergic nerves have little or no effect on the adrenergic nerve function in mesenteric arteries. The cholinergic nerves innervating mesenteric arteries do not mediate direct vascular responses.

  11. Counter-part Test and Code Analysis of the Integral Test Loop, SNUF

    International Nuclear Information System (INIS)

    Park, Goon Cherl; Bae, B. U.; Lee, K. H.; Cho, Y. J.

    2007-02-01

    The thermal-hydraulic phenomena of Direct Vessel Injection (DVI) line Small-Break Loss-of-Coolant Accident (SBLOCA) in pressurized water reactor, APR1400, were investigated. The reduced-height and reduced-pressure integral test loop, SNUF (Seoul National University Facility), was constructed with scaling down the prototype. For the appropriate test conditions in the experiment of SNUF, the energy scaling methodology was suggested as scaling the coolant mass inventory and thermal power for the reduced-pressure condition. From the MARS code analysis, the energy scaling methodology was confirmed to show the reasonable transient when ideally scaled-down SNUF model was compared to the prototype model. In the experiments according to the conditions determined by energy scaling methodology, the phenomenon of downcomer seal clearing had a dominant role in decrease of the system pressure and increase of the coolant level of core. The experimental results was utilized to validate the calculation capability of MARS

  12. Automated method for identification and artery-venous classification of vessel trees in retinal vessel networks.

    Science.gov (United States)

    Joshi, Vinayak S; Reinhardt, Joseph M; Garvin, Mona K; Abramoff, Michael D

    2014-01-01

    The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV) classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.

  13. Pressure vessel for nuclear reactor plant consisting of several pre-stressed cast pressure vessels

    International Nuclear Information System (INIS)

    Bodmann, E.

    1984-01-01

    Several cylindrical pressure vessel components made of pressure castings are arranged on a sector of a circle around the cylindrical cast pressure vessel for accommodating the helium cooled HTR. Each component pressure vessel is connected to the reactor vessel by a horizontal gas duct. The contact surfaces between reactor and component pressure vessel are in one plane. In the spaces between the individual component pressure vessels, there are supporting blocks made of cast iron, which are hollow and also have flat surfaces. With the reactor vessel and the component pressure vessels they form a disc-shaped connecting part below and above the gas ducts. (orig./PW)

  14. ITER vacuum vessel design and electromagnetic analysis on in-vessel components

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.; Iizuka, T.

    1995-01-01

    Major functional requirements for the vacuum vessel are to provide the first safety barrier and to support electromagnetic loads due to plasma disruptions and vertical displacement events, and to withstand plausible accidents without losing confinement. A double wall structure concept has been developed for the vacuum vessel due to its beneficial characteristics from the viewpoints of structural integrity and electrical continuity. An electromagnetic analysis of the blanket modules and the vacuum vessel has been performed to investigate force distributions on in-vessel components. According to the vertical displacement events (VDE) scenario, which assumes a critical q-value of 1.5, the total downward vertical force, induced by coupling between the eddy current and external fields, is about 110 MN. We have performed a stress analysis for the vacuum vessel using the VDE disruption forces acting on the blankets, and a maximum stress intensity of 112 MPa was obtained in the vicinity of the lower support of the vessel. (orig.)

  15. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  16. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  17. Role of arginase in vessel wall remodeling

    Directory of Open Access Journals (Sweden)

    William eDurante

    2013-05-01

    Full Text Available Arginase metabolizes the semi-essential amino acid L-arginine to L-ornithine and urea. There are two distinct isoforms of arginase, arginase I and II, which are encoded by separate genes and display differences in tissue distribution, subcellular localization, and molecular regulation. Blood vessels express both arginase I and II but their distribution appears to be cell-, vessel-, and species-specific. Both isoforms of arginase are induced by numerous pathologic stimuli and contribute to vascular cell dysfunction and vessel wall remodeling in several diseases. Clinical and experimental studies have documented increases in the expression and/or activity of arginase I or II in blood vessels following arterial injury and in pulmonary and arterial hypertension, aging, and atherosclerosis. Significantly, pharmacological inhibition or genetic ablation of arginase in animals ameliorates abnormalities in vascular cells and normalizes blood vessel architecture and function in all of these pathological states. The detrimental effect of arginase in vascular remodeling is attributable to its ability to stimulate vascular smooth muscle cell and endothelial cell proliferation, and collagen deposition by promoting the synthesis of polyamines and L-proline, respectively. In addition, arginase adversely impacts arterial remodeling by directing macrophages towards an inflammatory phenotype. Moreover, the proliferative, fibrotic, and inflammatory actions of arginase in the vasculature are further amplified by its capacity to inhibit nitric oxide synthesis by competing with nitric oxide synthase for substrate, L-arginine. Pharmacologic or molecular approaches targeting specific isoforms of arginase represent a promising strategy in treating obstructive fibroproliferative vascular disease.

  18. Integration of ITER in-vessel diagnostic components in the vacuum vessel

    International Nuclear Information System (INIS)

    Encheva, A.; Bertalot, L.; Macklin, B.; Vayakis, G.; Walker, C.

    2009-01-01

    The integration of ITER in-vessel diagnostic components is an important engineering activity. The positioning of the diagnostic components must correlate not only with their functional specifications but also with the design of the major parts of ITER torus, in particular the vacuum vessel, blanket modules, blanket manifolds, divertor, and port plugs, some of which are not yet finally designed. Moreover, the recently introduced Edge Localised Mode (ELM)/Vertical Stability (VS) coils mounted on the vacuum vessel inner wall call for not only more than a simple review of the engineering design settled down for several years now, but also for a change in the in-vessel distribution of the diagnostic components and their full impact has yet to be determined. Meanwhile, the procurement arrangement (a document defining roles and responsibilities of ITER Organization and Domestic Agency(s) (DAs) for each in-kind procurement including technical scope of work, quality assurance requirements, schedule, administrative matters) for the vacuum vessel must be finalized. These make the interface process even more challenging in terms of meeting the vacuum vessel (VV) procurement arrangement's deadline. The process of planning the installation of all the ITER diagnostics and integrating their installation into the ITER Integrated Project Schedule (IPS) is now underway. This paper covers the progress made recently on updating and issuing the interfaces of the in-vessel diagnostic components with the vacuum vessel, outlines the requirements for their attachment and summarises the installation sequence.

  19. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  20. Pressure vessels for reactors made from structural steel with limited tensile strength

    International Nuclear Information System (INIS)

    Machatti, H.

    1973-01-01

    The reactor pressure vessel is prestressed in several directions with prestressing elements fabricated of steel with a high yielding point. This design allows a substantial reduction of wall thickness or an increase of the inner diameter at equal wall thickness. The prestress of the prestressing elements is designed to achieve a maximum stress release of the vessel walls at normal operating conditions and to fully utilize the maximum load of the vessel walls. For safety reasons the cross section of the prestressing elements is constructed in a way that strain is always 20 % lower the yield point. (P.K.)

  1. Ex-vessel core catcher design requirements and preliminary concepts evaluation

    International Nuclear Information System (INIS)

    Friedland, A.J.; Tilbrook, R.W.

    1974-01-01

    As part of the overall study of the consequences of a hypothetical failure to scram following loss of pumping power, design requirements and preliminary concepts evaluation of an ex-vessel core catcher (EVCC) were performed. EVCC is the term applied to a class of devices whose primary objective is to provide a stable subcritical and coolable configuration within containment following a postulated accident in which it is assumed that core debris has penetrated the Reactor Vessel and Guard Vessel. Under these assumed conditions a set of functional requirements were developed for an EVCC and several concepts were evaluated. The studies were specifically directed toward the FFTF design considering the restraints imposed by the physical design and construction of the FFTF plant

  2. A state of the art on penetration failure estimation under external vessel cooling

    International Nuclear Information System (INIS)

    Min, B. T.; Park, R. J.; Kang, K. H.; Cho, Y. R.; Kim, J. W.; Kim, S. B.; Park, S. Y.; Lee, K. Y.

    2000-04-01

    A state of the art on penetration failure was reviewed and analyzed to establish the direction of the experimental program in the KNGR and to decide the test section design. The interaction between the corium and the reactor vessel and the corium behavior in the lower plenum of the reactor vessel were analyzed to investigate the penetration effect on severe accident progression, and the TMI-2 accident was investigated in the point of penetration failure. Theoretical model and experiment results on penetration failure under the severe accident were investigated and reviewed to establish the direction of the experimental program on the estimation of the penetration failure in the KNGR. These results were compared with the TMI-2 results. The existing test facilities on penetration failure were investigated and reviewed to decide the test section design. It can be said from the state of the art review that penetration in the lower plenum of the reactor vessel is a week point in the reactor vessel failure under the severe accident, but the reactor vessel may not be failed by penetration failure in condition with the coolant supply to the penetration. Since the penetration is different with reactor types and there is no study on estimation of the penetration welding, it is necessary to investigate failure or not of the penetration in condition with external vessel cooling to maintain the reactor vessel integrity in KNGR. In the present experimental program on the integrity estimation of the KNGR penetration, the aluminum oxide melt by thermite reaction and the test section with one penetration of the real size and real material were selected. The melt mass, the pressure of the system, and the vessel geometry were selected as an experimental parameter. (author)

  3. Tumor Blood Vessel Dynamics

    Science.gov (United States)

    Munn, Lance

    2009-11-01

    ``Normalization'' of tumor blood vessels has shown promise to improve the efficacy of chemotherapeutics. In theory, anti-angiogenic drugs targeting endothelial VEGF signaling can improve vessel network structure and function, enhancing the transport of subsequent cytotoxic drugs to cancer cells. In practice, the effects are unpredictable, with varying levels of success. The predominant effects of anti-VEGF therapies are decreased vessel leakiness (hydraulic conductivity), decreased vessel diameters and pruning of the immature vessel network. It is thought that each of these can influence perfusion of the vessel network, inducing flow in regions that were previously sluggish or stagnant. Unfortunately, when anti-VEGF therapies affect vessel structure and function, the changes are dynamic and overlapping in time, and it has been difficult to identify a consistent and predictable normalization ``window'' during which perfusion and subsequent drug delivery is optimal. This is largely due to the non-linearity in the system, and the inability to distinguish the effects of decreased vessel leakiness from those due to network structural changes in clinical trials or animal studies. We have developed a mathematical model to calculate blood flow in complex tumor networks imaged by two-photon microscopy. The model incorporates the necessary and sufficient components for addressing the problem of normalization of tumor vasculature: i) lattice-Boltzmann calculations of the full flow field within the vasculature and within the tissue, ii) diffusion and convection of soluble species such as oxygen or drugs within vessels and the tissue domain, iii) distinct and spatially-resolved vessel hydraulic conductivities and permeabilities for each species, iv) erythrocyte particles advecting in the flow and delivering oxygen with real oxygen release kinetics, v) shear stress-mediated vascular remodeling. This model, guided by multi-parameter intravital imaging of tumor vessel structure

  4. Superficial vessel reconstruction with a multiview camera system

    Science.gov (United States)

    Marreiros, Filipe M. M.; Rossitti, Sandro; Karlsson, Per M.; Wang, Chunliang; Gustafsson, Torbjörn; Carleberg, Per; Smedby, Örjan

    2016-01-01

    Abstract. We aim at reconstructing superficial vessels of the brain. Ultimately, they will serve to guide the deformation methods to compensate for the brain shift. A pipeline for three-dimensional (3-D) vessel reconstruction using three mono-complementary metal-oxide semiconductor cameras has been developed. Vessel centerlines are manually selected in the images. Using the properties of the Hessian matrix, the centerline points are assigned direction information. For correspondence matching, a combination of methods was used. The process starts with epipolar and spatial coherence constraints (geometrical constraints), followed by relaxation labeling and an iterative filtering where the 3-D points are compared to surfaces obtained using the thin-plate spline with decreasing relaxation parameter. Finally, the points are shifted to their local centroid position. Evaluation in virtual, phantom, and experimental images, including intraoperative data from patient experiments, shows that, with appropriate camera positions, the error estimates (root-mean square error and mean error) are ∼1  mm. PMID:26759814

  5. Comparative analysis of methods for extracting vessel network on breast MRI images

    Science.gov (United States)

    Gaizer, Bence T.; Vassiou, Katerina G.; Lavdas, Eleftherios; Arvanitis, Dimitrios L.; Fezoulidis, Ioannis V.; Glotsos, Dimitris T.

    2017-11-01

    Digital processing of MRI images aims to provide an automatized diagnostic evaluation of regular health screenings. Cancerous lesions are proven to cause an alteration in the vessel structure of the diseased organ. Currently there are several methods used for extraction of the vessel network in order to quantify its properties. In this work MRI images (Signa HDx 3.0T, GE Healthcare, courtesy of University Hospital of Larissa) of 30 female breasts were subjected to three different vessel extraction algorithms to determine the location of their vascular network. The first method is an experiment to build a graph over known points of the vessel network; the second algorithm aims to determine the direction and diameter of vessels at these points; the third approach is a seed growing algorithm, spreading selection to neighbors of the known vessel pixels. The possibilities shown by the different methods were analyzed, and quantitative measurements were performed. The data provided by these measurements showed no clear correlation with the presence or malignancy of tumors, based on the radiological diagnosis of skilled physicians.

  6. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  7. An experimental study on feasibility of ex-vessel cooling through the external guide vessel

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Kim, Jong-Hwan; Park, Rae-Jun; Kim, Sang-Baik

    2000-01-01

    This paper presents the results of a series of experiments for assessing the efficacy of ex-vessel cooling through the external guide vessel during a severe accident. Four tests were performed in the LAVA test facility at KAERI, varying the boundary conditions at the outer surface of the vessel. The first test was a dry condition test conducted without cooling the outside of the vessel. On the other hand, in the second test, the cooling of the vessel surface was produced by gravity-driven forced injection of water along the annular gap of 25 mm between the vessel and the external guide vessel. Water flow rate was about 0.85 kg/s and total mass of available water was 300 kg. For the evaluation of the water flow rate effect, the third test was performed with a pool type cooling in the annulus without any circulation of water. These two external cooling tests were performed under elevated pressure of about 1.6 MPa. Finally, the fourth test was conducted under atmospheric pressure to evaluate the effect of system pressure on boiling heat transfer characteristics. In the dry test and the pool type ex-vessel cooling test performed under atmospheric pressure, the vessel was failed by a melt penetration at about 40 degree upper position from the vessel bottom, which is coincident with the boundary of the Al 2 O 3 /Fe melt separated layers. On the other hand, in both of the ex-vessel cooling tests conducted under elevated pressure of about 1.6 MPa, the vessel didn't fail. Compared with the pool boiling test, the vessel experienced effective cooling due to the inlet flow in the forced flow test. Synthesized the results of the tests, it was shown that the heat removal with ex-vessel cooling through the guide vessel is feasible, but the additional evaluations should be performed to guarantee enough thermal margin. (author)

  8. Special enclosure for a pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.; Wedellsborg, U.W.

    1993-01-01

    A pressure vessel enclosure is described comprising a primary pressure vessel, a first pressure vessel containment assembly adapted to enclose said primary pressure vessel and be spaced apart therefrom, a first upper pressure vessel jacket adapted to enclose the upper half of said first pressure vessel containment assembly and be spaced apart therefrom, said upper pressure vessel jacket having an upper rim and a lower rim, each of said rims connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, mean for connecting in a sealable relationship said upper rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, means for connecting in a sealable relationship said lower rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a first lower pressure vessel jacket adapted to enclose the lower half of said first pressure vessel containment assembly and be spaced apart therefrom, said lower pressure vessel jacket having an upper rim connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, and means for connecting in a sealable relationship said upper rim of said first lower pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a second upper pressure vessel jacket adapted to enclose said first upper pressure vessel jacket and be spaced apart therefrom, said second upper pressure vessel jacket having an upper rim and a lower rim, each of said rims adapted to slidably engage the outer surface of said first upper pressure vessel jacket, means for sealing said rims, a second lower pressure vessel jacket adapted to enclose said first lower pressure vessel jacket and be spaced apart therefrom

  9. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  10. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  11. Investigation of flow stabilization in a compact reactor vessel of a FBR. Flow visualization in a reactor vessel

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Igarashi, Minoru; Kimura, Nobuyuki; Kamide, Hideki

    2002-01-01

    In the feasibility studies of Commercialized Fast Breeder Reactor Cycle System, a compact reactor vessel is considered from economical improvement point of a sodium cooled loop type fast reactor. The flow field was visualized by water experiment for a reactor vessel with 'a column type UIS (Upper Internal Structure)', which has a slit for fuel handling mechanism and is useful for a compact fast reactor. In this research, the 1/20 scale test equipment using water was made to understand coolant flow through a slit of a column type UIS' and fundamental behavior of reactor upper plenum flow. In the flow visualization tests, tracer particles were added in the water, and illuminated by the slit-shaped pulse laser. The flow visualization image was taken with a CCD camera. We obtained fluid velocity vectors from the visualization image using the Particle Imaging Velocimetry (PIV). The results are as follows. 1. Most of coolant flow through a slit of 'column type UIS' arrived the dip plate directly. In the opposite side of a slit, most of coolant flowed toward reactor vessel wall before it arrived the dip plate. 2. The PIV was useful to measure the flow field in the reactor vessel. The obtained velocity field was consistent with the flow visualization result. 3. The jet through the UIS slit was dependent on the UIS geometry. There is a possibility to control the jet by the UIS geometry. (author)

  12. Regulation of blood vessels by prolactin and vasoinhibins.

    Science.gov (United States)

    Clapp, Carmen; Thebault, Stéphanie; Macotela, Yazmín; Moreno-Carranza, Bibiana; Triebel, Jakob; Martínez de la Escalera, Gonzalo

    2015-01-01

    Prolactin (PRL) stimulates the growth of new blood vessels (angiogenesis) either directly through actions on endothelial cells or indirectly by upregulating proangiogenic factors like vascular endothelial growth factor (VEGF). Moreover, PRL acquires antiangiogenic properties after undergoing proteolytic cleavage to vasoinhibins, a family of PRL fragments (including 16 kDa PRL) with potent antiangiogenic, vasoconstrictive, and antivasopermeability effects. In view of the opposing actions of PRL and vasoinhibins, the regulation of the proteases responsible for specific PRL cleavage represents an efficient mechanism for controlling blood vessel growth and function. This review briefly describes the vascular actions of PRL and vasoinhibins, and addresses how their interplay could help drive biological effects of PRL in the context of health and disease.

  13. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  14. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  15. Towards cavitation-enhanced permeability in blood vessel on a chip

    Science.gov (United States)

    De Luca, R.; Silvani, G.; Scognamiglio, C.; Sinibaldi, G.; Peruzzi, G.; Chinappi, M.; Kiani, M. F.; Casciola, C. M.

    2017-08-01

    The development of targeted delivery systems releasing pharmaceutical agents directly at the desired site of action may improve their therapeutic efficiency while minimizing damage to healthy tissues, toxicity to the patient and drug waste. In this context, we have developed a bio-inspired microdevice mimicking the tumour microvasculature which represents a valuable tool for assessing the enhancement of blood vessel permeability due to cavitation. This novel system allows us to investigate the effects of ultrasound-driven microbubbles that temporarily open the endothelial intercellular junctions allowing drug to extravasate blood vessels into tumour tissues. The blood vessel on a chip consists of a tissue chamber and two independent vascular channels (width 200 µm, height 100 µm, length 2762 µm) cultured with endothelial cells placed side-by-side and separated by a series of 3 µm pores. Its geometry and dimensions mimic the three-dimensional morphology, size and flow characteristics of microvessels in vivo. The early stage of this project had a twofold objective: 1. To define the protocol for culturing of Human Umbilical Vein Endothelial Cells (HUVECs) within the vascular channel; 2. To develop a fluorescence based microscopy technique for measuring permeability. We have developed a reliable and reproducible protocol to culture endothelial cells within the artificial vessels in a realistic manner: HUVECs show the typical elongated shape in the direction of flow, exhibit tight junction formation and form a continuous layer with a central lumen that completely covers the channels wall. As expected, the permeability of cell-free device is higher than the one cultured with HUVECs in the vascular channels. The proposed blood vessel on a chip and the permeability measurement protocol have a significant potential to allow for the study of cavitation-enhanced permeability of the endothelium and improve efficiency in screening drug delivery systems.

  16. In-vessel tritium

    International Nuclear Information System (INIS)

    Ueda, Yoshio; Ohya, Kaoru; Ashikawa, Naoko; Ito, Atsushi M.; Kato, Daiji; Kawamura, Gakushi; Takayama, Arimichi; Tomita, Yukihiro; Nakamura, Hiroaki; Ono, Tadayoshi; Kawashima, Hisato; Shimizu, Katsuhiro; Takizuka, Tomonori; Nakano, Tomohide; Nakamura, Makoto; Hoshino, Kazuo; Kenmotsu, Takahiro; Wada, Motoi; Saito, Seiki; Takagi, Ikuji; Tanaka, Yasunori; Tanabe, Tetsuo; Yoshida, Masafumi; Toma, Mitsunori; Hatayama, Akiyoshi; Homma, Yuki; Tolstikhina, Inga Yu.

    2012-01-01

    The in-vessel tritium research is closely related to the plasma-materials interaction. It deals with the edge-plasma-wall interaction, the wall erosion, transport and re-deposition of neutral particles and the effect of neutral particles on the fuel recycling. Since the in-vessel tritium shows a complex nonlinear behavior, there remain many unsolved problems. So far, behaviors of in-vessel tritium have been investigated by two groups A01 and A02. The A01 group performed experiments on accumulation and recovery of tritium in thermonuclear fusion reactors and the A02 group studied theory and simulation on the in-vessel tritium behavior. In the present article, outcomes of the research are reviewed. (author)

  17. The 'Safari' Technique to Perform Difficult Subintimal Infragenicular Vessels

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Stefanini, Matteo; Maresca, Luciano; Spinelli, Alessio; Colangelo, Vittorio; Reale, Carlo Andrea; Pampana, Enrico; Simonetti, Giovanni

    2007-01-01

    The purpose of this study was to describe the efficacy of planned combined subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) to obtain the precise recanalization of the patent portion of a distal runoff vessel in critical limb ischemia (CLI) patients presenting long occlusions involving the popliteal trifurcation. Four patients at risk of limb loss due to long occlusions involving the leg vessel tree and not suitable for a surgical bypass were treated by the subintimal antegrade and retrograde (posterior tibial or anterior tibial artery) approach. The patent portion of the runoff vessel was previously assessed by magnetic resonance angiography (MRA) and directly punctured under Doppler ultrasound (US) guidance. A subintimal channel rendezvous was performed to allow snaring of the guidewires. Subsequently, a balloon dilatation was performed without stent deployment. All patients were successfully recanalized and had complete healing of the limb lesions. At the 12-month follow-up all patients showed clinical improvement with no major complications related to the procedure. This combined antegrade and retrograde subintimal approach is currently an excellent endovascular option in patients with long occlusions extending onto the leg vessels trifurcation and at risk of limb loss

  18. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  19. MH17: the Malaysian experience.

    Science.gov (United States)

    Khoo, L S; Hasmi, A H; Abdul Ghani Aziz, S A; Ibrahim, M A; Mahmood, M S

    2016-04-01

    A disaster is a natural or man-made (or technological) hazard resulting in an event of substantial extent causing significant physical damage or destruction, loss of life, or drastic change to the environment. It is a phenomenon that can cause damage to life and property and destroy the economic, social and cultural life of the people; and overwhelms the capacity of the community to cope with the event. The recent tragic aviation accidents in 2014 involving Malaysia Airlines flights MH370 and MH17 shocked the world in an unprecedented manner. This paper focuses on the Malaysian experience in the MH17 mission in Ukraine as well as the first ever international Disaster Victim Identification (DVI) operation for the Malaysian DVI team. The DVI operations in Hilversum, the Netherlands were well described in stages. The Netherlands' Landelijk Team Forensische Opsporing as the lead DVI team in Hilversum operated systematically, ensuring the success of the whole mission. This paper discusses the lessons learned by the Malaysian team on proper DVI structure, inter- and intra-agency cooperation, facilities planning and set up, logistics and health and safety aspects, as well as effective communication and collaboration with other international delegates. Several issues and challenges faced by the Malaysian team were also documented. In addition, the authors shared views, opinions and recommendations for a more comprehensive DVI operation in the future.

  20. NCSX Vacuum Vessel Fabrication

    International Nuclear Information System (INIS)

    Viola ME; Brown T; Heitzenroeder P; Malinowski F; Reiersen W; Sutton L; Goranson P; Nelson B; Cole M; Manuel M; McCorkle D.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is being constructed at the Princeton Plasma Physics Laboratory (PPPL) in conjunction with the Oak Ridge National Laboratory (ORNL). The goal of this experiment is to develop a device which has the steady state properties of a traditional stellarator along with the high performance characteristics of a tokamak. A key element of this device is its highly shaped Inconel 625 vacuum vessel. This paper describes the manufacturing of the vessel. The vessel is being fabricated by Major Tool and Machine, Inc. (MTM) in three identical 120 o vessel segments, corresponding to the three NCSX field periods, in order to accommodate assembly of the device. The port extensions are welded on, leak checked, cut off within 1-inch of the vessel surface at MTM and then reattached at PPPL, to accommodate assembly of the close-fitting modular coils that surround the vessel. The 120 o vessel segments are formed by welding two 60 o segments together. Each 60 o segment is fabricated by welding ten press-formed panels together over a collapsible welding fixture which is needed to precisely position the panels. The vessel is joined at assembly by welding via custom machined 8-inch (20.3 cm) wide spacer ''spool pieces''. The vessel must have a total leak rate less than 5 X 10 -6 t-l/s, magnetic permeability less than 1.02(micro), and its contours must be within 0.188-inch (4.76 mm). It is scheduled for completion in January 2006

  1. Simulation of In-Vessel Corium Retention through External Reactor Vessel Cooling for SMART using SIMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin-Sung; Son, Donggun; Park, Rae-Joon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Thermal load analysis from the corium pool to the outer reactor vessel in the lower plenum of the reactor vessel is necessary to evaluate the effect of the IVR-ERVC during a severe accident for SMART. A computational code called SIMPLE (Sever Invessel Melt Progression in Lower plenum Environment) has been developed for analyze transient behavior of molten corium in the lower plenum, interaction between corium and coolant, and heat-up and ablation of reactor vessel wall. In this study, heat load analysis of the reactor vessel for SMART has been conducted using the SIMPLE. Transient behavior of the molten corium in the lower plenum and IVR-ERVC for SMART has been simulated using SIMPLE. Heat flux from the corium pool to the outer reactor vessel is concentrated in metallic layer by the focusing effect. As a result, metallic layer shows higher temperature than the oxidic layer. Also, vessel wall of metallic layer has been ablated by the high in-vessel temperature. Ex-vessel temperature of the metallic layer was maintained 390 K and vessel thickness was maintained 14 cm. It means that the reactor vessel integrity is maintained by the IVR-ERVC.

  2. Materials surveillance program for C-E NSSS reactor vessels

    International Nuclear Information System (INIS)

    Koziol, J.J.

    1977-01-01

    Irradiation surveillance programs for light water NSSS reactor vessels provide the means by which the utility can assess the extent of neutron-induced changes in the reactor vessel materials. These programs are conducted to verify, by direct measurement, the conservatism in the predicted radiation-induced changes and hence the operational parameters (i.e., heat-up, cooldown, and pressurization rates). In addition, such programs provide assurance that the scheduled adjustments in the operational parameters are made with ample margin for safe operation of the plant. During the past 3 years, several documents have been promulgated establishing the criteria for determining both the initial properties of the reactor vessel materials as well as measurement of changes in these initial properties as a result of irradiation. These documents, ASTM E-185-73, ''Recommended Practice for Surveillance Tests for Nuclear Reactor Vessels,'' and Appendix H to 10 CFR 50, ''Reactor Vessel Material Surveillance Program Requirements,'' are complementary to each other. They are the result of a change in the basic philosophy regarding the design and analysis of reactor vessels. In effect, the empirical ''transition temperature approach,'' which was used for design, was replaced by the ''analytical fracture mechanics approach.'' The implementation of this technique was described in Welding Research Council Bulletin 1975 and Appendix G to ASME Code Section III. Further definition of requirements appears in Appendix G to 10 CFR 50 published in July 1973. It is the intent of this paper to describe (1) a typical materials surveillance program for the reactor vessel of a Combustion Engineering NSSS, and (2) how the results of such programs, as well as experimental programs provide feed-back for improvement of materials to enhance their radiation resistance and thereby further improve the safety and reliability of future plants. (author)

  3. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  4. Flow patterns on spectral-domain optical coherence tomography reveal flow directions at retinal vessel bifurcations

    DEFF Research Database (Denmark)

    Willerslev, Anne; Li, Xiao Q; Munch, Inger C

    2014-01-01

    PURPOSE: To study intravascular characteristics of flowing blood in retinal vessels using spectral-domain optical coherence tomography (SD-OCT). METHODS: Examination of selected arterial bifurcations and venous sites of confluence in 25 healthy 11-year-old children recruited as an ad hoc subsample...

  5. Optimized design of an ex-vessel cooling thermosyphon for decay heat removal in SFR

    International Nuclear Information System (INIS)

    Choi, Jae Young; Jeong, Yong Hoon; Song, Sub Lee; Chang, Soon Heung

    2017-01-01

    Passive decay heat removal and sodium fire are two major key issues of nuclear safety in sodium-cooled fast reactor (SFR). Several decay heat removal systems (DHR) were suggested for SFR around the world so far. Those DHRS mainly classified into two concepts: Direct reactor cooling system and ex-vessel cooling system. Direct reactor cooling method represented by PDHRS from PGSFR has disadvantages on its additional in-vessel structure and potential sodium fire risk due to the sodium-filled heat exchanger exposed to air. Contrastively, ex-vessel cooling method represented by RVACS from PRISM has low decay heat removal performance, which cannot be applicable to large scale reactors, generally over 1000 MWth. No passive DHRSs which can solve both side of disadvantages has been suggested yet. The goal of this study was to propose ex-vessel cooling system using two-phase closed thermosyphon to compensate the disadvantages of the past DHRSs. Reference reactor was Innovative SFR (iSFR), a pool-type SFR designed by KAIST and featured by extended core lifetime and increased thermal efficiency. Proposed ex-vessel cooling system consisted of 4 trains of thermosyphons and designed to remove 1% of thermal power with 10% of margin. The scopes of this study were design of proposed passive DHRS, validation of system analysis and optimization of system design. Mercury was selected as working fluid to design ex-vessel thermosyphon in consideration of system geometry, operating temperature and required heat flux. SUS 316 with chrome coated liner was selected as case material to resist against high corrosivity of mercury. Thermosyphon evaporator was covered on the surface of reactor vessel as the geometry of hollow shell filled with mercury. Condenser was consisted of finned tube bundles and was located in isolated water pool, the ultimate heat sink. Operation limits and thermal resistance was estimated to guarantee whether the design was adequate. System analysis was conducted by in

  6. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  7. Conceptual design of EAST flexible in-vessel inspection system

    International Nuclear Information System (INIS)

    Peng, X.B.; Song, Y.T.; Li, C.C.; Lei, M.Z.; Li, G.

    2010-01-01

    Remote handling technology, especially the flexible in-vessel inspection system (FIVIS) without breaking the working condition of the vacuum vessel, has been identified as one major challenge on the maintenance for the future tokamak fusion reactor. The FIVIS introduced here is specially developed for EAST superconducting tokamak that has actively cooled plasma facing components (PFCs). It aims flexible close-up inspection of EAST PFCs to help the understanding of operation issues that could occur in the vacuum vessel. This paper resumes the preliminary work of the FIVIS project, including the requirement analysis and the development of the conceptual design. The FIVIS consists out of a long reach multi-articulated manipulator and a process tool. The manipulator has a modular design for its subsystems and can reach all areas of the first wall in the distance of 15 mm and in the range of ±90 o along toroidal direction. It will be folded and hidden in the designated horizontal port during plasma discharge period.

  8. New paradigm for prediction of radiation life-time of reactor pressure vessel

    International Nuclear Information System (INIS)

    Kotrechko, S.A.; Meshkov, Yu.Ya.; Neklyudov, I.M.; Revka, V.N.

    2011-01-01

    New paradigm for prediction of radiation life-time of reactor pressure vessel is presented. Equation for limiting state of reactor pressure vessel wall with crack-like defect is obtained. It is exhibited that the value of critical fluence Φ c may be determined not by shift of critical temperature of fracture of surveillance specimen, which is indirect characteristic, but by direct method, namely, by the condition of initiation of brittle fracture of irradiated metal ahead of a crack in RPV wall. Within the framework of engineering version of LA to fracture the technique for Φ c ascertainment is developed. Prediction of Φ c for WWER pressure vessels demonstrates potentialities of this technique.

  9. Analysis of ex-vessel steam explosion with MC3D

    International Nuclear Information System (INIS)

    Leskovar, M.; Mavko, B.

    2007-01-01

    An ex-vessel steam explosion may occur when, during a severe reactor accident, the reactor vessel fails and the molten core pours into the water in the reactor cavity. A steam explosion is a fuel coolant interaction process where the heat transfer from the melt to water is so intense and rapid that the timescale for heat transfer is shorter than the timescale for pressure relief. This can lead to the formation of shock waves and production of missiles that may endanger surrounding structures. A strong enough steam explosion in a nuclear power plant could jeopardize the containment integrity and so lead to a direct release of radioactive material to the environment. In the paper, different scenarios of ex-vessel steam explosions in a typical pressurized water reactor cavity are analyzed with the code MC3D, which was developed for the simulation of fuel-coolant interactions. A comprehensive parametric study was performed varying the location of the melt release (central, left and right side melt pour), the cavity water subcooling, the primary system overpressure at vessel failure and the triggering time for explosion calculations. The main purpose of the study was to determine the most challenging ex-vessel steam explosion cases in a typical pressurized water reactor and to estimate the expected pressure loadings on the cavity walls. The performed analysis shows that for some ex-vessel steam explosion scenarios significantly higher pressure loads are predicted than obtained in the OECD programme SERENA Phase 1. (author)

  10. Development of cold moderator vessel for the spallation neutron source. Flow field measurements and thermal hydraulic analyses in cold moderator vessel

    International Nuclear Information System (INIS)

    Aso, Tomokazu; Kaminaga, Masanori; Terada, Atsuhiko; Hino, Ryutaro

    2001-01-01

    The Japan Atomic Energy Research Institute is developing a several MW-scale spallation target system under the High-Intensity Accelerator Project. A cold moderator using supercritical hydrogen is one of the key components in the target system, which directly affects the neutronic performance both in intensity and resolution. Since a hydrogen temperature rise in the moderator vessel affects the neutronic performance, it is necessary to suppress the recirculation and stagnant flows which cause hot spots. In order to develop the conceptual design of the moderator structure in progress, the flow field was measured using a PIV (Particle Image Velocimetry) system under water flow conditions using a flat model that simulated a moderator vessel. From these results, the flow field such as recirculation flows, stagnant flows etc. was clarified. The hydraulic analytical results using the standard k-ε model agreed well with experimental results. Thermal-hydraulic analyses in the moderator vessel were carried out under liquid hydrogen conditions. Based on these results, we clarified the possibility of suppressing the local temperature rise within 3 K under 2 MW operating condition. (author)

  11. Reactor pressure vessel failure probability following through-wall cracks due to pressurized thermal shock events

    International Nuclear Information System (INIS)

    Simonen, F.A.; Garnich, M.R.; Simonen, E.P.; Bian, S.H.; Nomura, K.K.; Anderson, W.E.; Pedersen, L.T.

    1986-04-01

    A fracture mechanics model was developed at the Pacific Northwest Laboratory (PNL) to predict the behavior of a reactor pressure vessel following a through-wall crack that occurs during a pressurized thermal shock (PTS) event. This study, which contributed to a US Nuclear Regulatory Commission (NRC) program to study PTS risk, was coordinated with the Integrated Pressurized Thermal Shock (IPTS) Program at Oak Ridge National Laboratory (ORNL). The PNL fracture mechanics model uses the critical transients and probabilities of through-wall cracks from the IPTS Program. The PNL model predicts the arrest, reinitiation, and direction of crack growth for a postulated through-wall crack and thereby predicts the mode of vessel failure. A Monte-Carlo type of computer code was written to predict the probabilities of the alternative failure modes. This code treats the fracture mechanics properties of the various welds and plates of a vessel as random variables. Plant-specific calculations were performed for the Oconee-1, Calvert Cliffs-1, and H.B. Robinson-2 reactor pressure vessels for the conditions of postulated transients. The model predicted that 50% or more of the through-wall axial cracks will turn to follow a circumferential weld. The predicted failure mode is a complete circumferential fracture of the vessel, which results in a potential vertically directed missile consisting of the upper head assembly. Missile arrest calculations for the three nuclear plants predict that such vertical missiles, as well as all potential horizontally directed fragmentation type missiles, will be confined to the vessel enclosre cavity. The PNL failure mode model is recommended for use in future evaluations of other plants, to determine the failure modes that are most probable for postulated PTS events

  12. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  13. 33 CFR 164.78 - Navigation under way: Towing vessels.

    Science.gov (United States)

    2010-07-01

    ...) Evaluates the danger of each closing visual or radar contact; (5) Knows and applies the variation and... type of correction; (6) Knows the speed and direction of the current, and the set, drift, and tidal... vessels. 164.78 Section 164.78 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...

  14. Integrated conjugate heat transfer analysis method for in-vessel retention with external reactor vessel cooling - 15477

    International Nuclear Information System (INIS)

    Park, J.W.; Bae, J.H.; Seol, W.C.

    2015-01-01

    An integrated conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue. The method calculates steady-state 3-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel 3-layered stratified corium (metallic pool, oxide pool and heavy metal) and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel. The 3-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method and ex-vessel boiling regimes are parametrically considered. The thermal integrity of a reactor vessel is addressed in terms of un-molten thickness profile. The vessel 3-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate inside the oxide pool and the 3-dimensional vessel heat transfer provides a much larger minimum vessel wall thickness. (authors)

  15. ALICE HMPID Radiator Vessel

    CERN Document Server

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  16. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  17. Sampling and Analysis Plan for PUREX canyon vessel flushing

    International Nuclear Information System (INIS)

    Villalobos, C.N.

    1995-01-01

    A sampling and analysis plan is necessary to provide direction for the sampling and analytical activities determined by the data quality objectives. This document defines the sampling and analysis necessary to support the deactivation of the Plutonium-Uranium Extraction (PUREX) facility vessels that are regulated pursuant to Washington Administrative Code 173-303

  18. Simulation of VDE under intervention of vertical stability control and vertical electromagnetic force on the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Miyamoto, S.; Sugihara, M.; Shinya, K.; Nakamura, Y.; Toshimitsu, S.; Lukash, V.E.; Khayrutdinov, R.R.; Sugie, T.; Kusama, Y.; Yoshino, R.

    2012-01-01

    Highlights: ► Taking account of intervention of VS control, VDE simulations were carried out. ► Malfunctioning of VS circuit (positive feedback) enhances the vertical force. ► The worst case was explored for vertical force on the ITER vacuum vessel. ► We confirmed the force is still within the design margin even if the worst case. - Abstract: Vertical displacement events (VDEs) and disruptions usually take place under intervention of vertical stability (VS) control and the vertical electromagnetic force induced on vacuum vessels is potentially influenced. This paper presents assessment of the force that arises from the VS control in ITER VDEs using a numerical simulation code DINA. The focus is on a possible malfunctioning of the ex-vessel VS control circuit: radial magnetic field is unintentionally applied to the direction of enhancing the vertical displacement further. Since this type of failure usually causes the largest forces (or halo currents) observed in the present experiments, this situation must be properly accommodated in the design of the ITER vacuum vessel. DINA analysis shows that although the ex-vessel VS control modifies radial field, it does not affect plasma motion and current quench behavior including halo current generation because the vacuum vessel shields the field created by the ex-vessel coils. Nevertheless, the VS control modifies the force on the vessel by directly acting on the eddy current carried by the conducting structures of the vessel. Although the worst case was explored in a range of plasma inductance and pattern of VS control in combination with the in-vessel VS control circuit, the result confirmed that the force is still within the design margin.

  19. Measurements of image characteristics of DSA installations

    International Nuclear Information System (INIS)

    Busch, H.P.; Strauss, L.G.; Freimarck, R.D.

    1984-01-01

    Measurements for quantifying the image characteristics were carried out on three DSA installations (DVI 1 - Philips, Angiotron - Siemens and DF 3000 - General Eletric). Contrast resolution was measured with a vessel phantom (General Electric) and spatial resolution with a lead grid. A further parameter was the dose entering the image intensifier. The Angiotron was used with an intensifier with 53 cm. diameter and the DF 3000 with temporal subtraction of the video images and the subtraction of dual energy images (hybrid technique). These measurements can be carried out quickly and easily and are a step towards standardisation of measurements of image characteristics of DSA installations. (orig.) [de

  20. Large-scale boiling experiments of the flooded cavity concept for in-vessel core retention

    International Nuclear Information System (INIS)

    Chu, T.Y.; Slezak, S.E.; Bentz, J.H.; Pasedag, W.F.

    1994-01-01

    This paper presents results of ex-vessel boiling experiments performed in the CYBL (CYlindrical BoiLing) facility. CYBL is a reactor-scale facility for confirmatory research of the flooded cavity concept for accident management. CYBL has a tank-within-a-tank design; the inner tank simulates the reactor vessel and the outer tank simulates the reactor cavity. Experiments with uniform and edge-peaked heat flux distributions up to 20 W/cm 2 across the vessel bottom were performed. Boiling outside the reactor vessel was found to be subcooled nucleate boiling. The subcooling is mainly due to the gravity head which results from flooding the sides of the reactor vessel. The boiling process exhibits a cyclic pattern with four distinct phases: direct liquid/solid contact, bubble nucleation and growth, coalescence, and vapor mass dispersion (ejection). The results suggest that under prototypic heat load and heat flux distributions, the flooded cavity in a passive pressurized water reactor like the AP-600 should be capable of cooling the reactor pressure vessel in the central region of the lower head that is addressed by these tests

  1. Skin and respiratory disorders following the identification of disaster victims in Thailand

    DEFF Research Database (Denmark)

    Huusom, Anja Julie; Agner, Tove; Backer, Vibeke

    2011-01-01

    The purpose was to assess disorders related to disaster victim identification (DVI) in a group of Danish forensic personnel that had performed disaster victim identification in Thailand after the 2004 tsunami. All individuals from the DVI team were screened using a questionnaire to identify....... Individuals with respiratory disorders were evaluated by a specialists in pulmonary medicine, based on the results of an extended lung function test and a skin prick test. Out of the 165 persons that worked with DVI in Thailand, 152 (92%) answered the questionnaire, and 24 underwent subsequent clinical...... examination. On examination, five persons were found to have skin disorders and four had airway disorders associated with the DVI work in Thailand. The allergy tests gave no support to the conditions being caused by exposure to disinfectants or other specific chemicals in any of the examined individuals...

  2. Application of flow-controllable accumulator and performance analysis in Korean Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jung, Byung-Ryul; Lee, Un-Chul

    1997-01-01

    The Korean Yonggwang Nuclear Power Plants 3 ampersand 4(YGN 3 ampersand 4) are the two-loop pressurized water reactor (PWR) nuclear steam supply systems, rated at 2,815 MW(thermal). They incorporate the safety injection system (SIS) consisting of the two high pressure (HPSI) pumps, two low pressure safety injection (LPSI) pumps, and four accumulators. The SIS is two headered arrangements, each to four cold legs injection (CLI) type which provides cooling to the core in the highly unlikely event of a loss-of-coolant accident (LOCA). In the current SIS, the LPSI pumps automatically start during a LOCA, and also provide the residual heat removal capability during the shutdown cooling. This paper presents the feasibility of the removal of the LPSI from the existing SIS with minor system changes, including the increase up to four in the HPSI pumps, direct vessel injection(DVI), and the flow-controllable accumulators. A double-ended rupture of one of the four cold legs in the YGN 3 ampersand 4 was simulated using RELAP5/MOD3.1 to determine the feasibility of the application of this new SIS design to the current nuclear power plants. As a result, the calculated reflooding peak cladding surface temperature(PCT) was comparable to that of original base calculation, and the downcomer and the core collapsed liquid level during reflooding were also comparable to those in the current safety system design. This large break, cold-leg LOCA analysis addresses the reflooding capability without credit for a LPSI pump system and the applicability of the new flow-controllable accumulator. Also this analysis confirms that the combination of new flow-controllable accumulators, DVI and the increased HPSI pumps maintain the peak cladding temperature below the prescribed limits. 14 refs., 4 figs., 3 tabs

  3. Heating and cooling system for an on-board gas adsorbent storage vessel

    Science.gov (United States)

    Tamburello, David A.; Anton, Donald L.; Hardy, Bruce J.; Corgnale, Claudio

    2017-06-20

    In one aspect, a system for controlling the temperature within a gas adsorbent storage vessel of a vehicle may include an air conditioning system forming a continuous flow loop of heat exchange fluid that is cycled between a heated flow and a cooled flow. The system may also include at least one fluid by-pass line extending at least partially within the gas adsorbent storage vessel. The fluid by-pass line(s) may be configured to receive a by-pass flow including at least a portion of the heated flow or the cooled flow of the heat exchange fluid at one or more input locations and expel the by-pass flow back into the continuous flow loop at one or more output locations, wherein the by-pass flow is directed through the gas adsorbent storage vessel via the by-pass line(s) so as to adjust an internal temperature within the gas adsorbent storage vessel.

  4. Reactor vessel stud closure system

    International Nuclear Information System (INIS)

    Spiegelman, S.R.; Salton, R.B.; Beer, R.W.; Malandra, L.J.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner apparatus for enabling the loosening or tightening of a stud nut on a reactor vessel stud. The apparatus is adapted to engage the vessel stud by closing a gripper around an upper end of the vessel stud when the apparatus is seated on the stud. Upon lifting the apparatus, the gripper releases the vessel stud so that the apparatus can be removed

  5. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  6. Large inelastic deformation analysis of steel pressure vessels at high temperature

    International Nuclear Information System (INIS)

    Ikonen, K.

    2001-01-01

    This publication describes the calculation methodology developed for a large inelastic deformation analysis of pressure vessels at high temperature. Continuum mechanical formulation related to a large deformation analysis is presented. Application of the constitutive equations is simplified when the evolution of stress and deformation state of an infinitesimal material element is considered in the directions of principal strains determined by the deformation during a finite time increment. A quantitative modelling of time dependent inelastic deformation is applied for reactor pressure vessel steels. Experimental data of uniaxial tensile, relaxation and creep tests performed at different laboratories for reactor pressure vessel steels are investigated and processed. An inelastic deformation rate model of strain hardening type is adopted. The model simulates well the axial tensile, relaxation and creep tests from room temperature to high temperature with only a few fitting parameters. The measurement data refined for the inelastic deformation rate model show useful information about inelastic deformation phenomena of reactor pressure vessel steels over a wide temperature range. The methodology and calculation process are validated by comparing the calculated results with measurements from experiments on small scale pressure vessels. A reasonably good agreement, when taking several uncertainties into account, is obtained between the measured and calculated results concerning deformation rate and failure location. (orig.)

  7. Structural analysis and evaluation for the design of pressure vessel

    International Nuclear Information System (INIS)

    Arai, K.; Uragami, K.; Funada, T.; Baba, K.; Kira, T.

    1977-01-01

    For the design of pressure vessel, the detailed structural analysis such as the fatigue analysis under operating conditions is required by ASME Code or Japanese regulation. Accordingly, it should be verified by the analysis that the design of the pressure vessel is in compliance with the stress limitation defined in the Code or the regulation. However, it was apparent that the analysis is very complicated and takes a lot of time to evaluate in accordance with the Code requirements. Thereupon we developed the computer program by which we can perform the stress analysis with correctness and comparatively in a short period of design work reflecting the calculation results on detailed drawings to be used for fabrication. The computer program is controlled in combination with the system of the design work and out put list of the program can be directly used for the stress analysis report which is issued to customers. In addition to the above computer program, we developed the specific three dimensional finite element computer program to make sure of the structural integrity of the vessel head and flanges which are most complex for the analysis compared with the stress distribution measured by strain gauges on the vessel head and flange. Besides the structural analysis, the fracture mechanics analysis for the purpose of preventing the pressure vessel from the brittle fracture during heat-up and cool-down operation is also important and thereby we showed herein that the pressure vessel is in safety against the brittle fracture for the specified operating conditions. As a result of the above-mentioned analysis, the pressure vessel is designed with safety from the stand-points of the structural intensity and the fracture mechanics. (auth.)

  8. Progress in understanding the mechanical behavior of pressure-vessel materials at elevated temperatures

    International Nuclear Information System (INIS)

    Swindeman, R.W.; Brinkman, C.R.

    1981-01-01

    Progress during the 1970's on the production of high-temperature mechanical properties data for pressure vessel materials was reviewed. The direction of the research was toward satisfying new data requirements to implement advances in high-temperature inelastic design methods. To meet these needs, servo-controlled testing machines and high-resolution extensometry were developed to gain more information on the essential behavioral features of high-temperature alloys. The similarities and differences in the mechanical response of various pressure vessel materials were identified. High-temperature pressure vessel materials that have received the most attention included Type 304 stainless steel, Type 316 stainless steel, 2 1/4 Cr-1 Mo steel, alloy 800H, and Hastelloy X

  9. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  10. Thermal Behavior of the Reactor Vessel Penetration Under External Vessel Cooling During a Severe Accident

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Park, Rae-Joon; Kim, Jong-Tae; Min, Byung-Tae; Lee, Ki-Young; Kim, Sang-Baik

    2004-01-01

    Experimental and analytical studies on the thermal behavior of reactor vessel penetration have been performed under external vessel cooling during a severe accident in the Korean next-generation reactor APR1400. Two types of tests, SUS-EXT and SUS-DRY with and without external vessel cooling, respectively, have been performed using sustained heating by an induction heater. Three tests have been carried out varying the cooling conditions at the vessel outer surface in the SUS-EXT tests. The experimental results have been thermally estimated using the LILAC computer code. The experimental results indicate that the inner surface of the vessel was ablated by the 45-mm thickness in the SUS-DRY test. Despite the total ablation of the welding material, the penetration was not ejected outside the vessel, which could be attributed to the thermal expansion of the penetration. Unlike the SUS-DRY test, the thickness of the ablation was ∼15 to 20 mm at most, so the welding was preserved in the SUS-EXT tests. It is concluded from the experimental results that the external vessel cooling highly affected the ablation configuration and the thermal behaviors of the vessel and the penetration. An increase in coolant mass flow rate from 0.047 to 0.152 kg/s had effects on the thermal behavior of the lower head vessel and penetration in the SUS-EXT tests. The LILAC analytical results on temperature distribution and ablation depth in the lower head vessel and penetration were very similar to the experimental results

  11. Experimental Study of Interactions Between Sub-oxidized Corium and Reactor Vessel Steel

    International Nuclear Information System (INIS)

    Bechta, S.V.; Khabensky, V.B.; Granovsky, V.S.; Krushinov, E.V.; Vitol, S.A.; Gusarov, V.V.; Almiashev, V.I.; Lopukh, D.B.; Tromm, W.; Miassoedov, A.; Bottomley, D.; Fischer, M.; Piluso, P.; Altstadt, E.; Willschutz, H.G.; Fichoti, F.

    2006-01-01

    One of the critical factors in the analysis of in-vessel melt retention is the vessel strength. It is, in particular, sensitive to the thickness of intact vessel wall, which, in its turn, depends on the thermal conditions and physicochemical interactions with corium. Physicochemical interaction of prototypic UO 2 -ZrO 2 -Zr corium melt and VVER vessel steel was examined during the 2. Phase of the ISTC METCOR Project. Rasplav-3 test facility was used for conducting four tests, in which the Zr oxidation degree and interaction front temperature were varied; in one of the tests, stainless steel was added to the melt. Direct experimental measurements and post-test analyses were used for determining corrosion kinetics and maximum corrosion depth (i.e. the physicochemical impact of corium on the cooled vessel steel specimens), as well as the steel temperature conditions during the interaction, and finally the structure and composition of crystallized ingots, including the interaction zone. The minimum temperature on the interaction front boundary, which determined its final position and maximum corrosion depth was ∼ 1090 deg. C. An empirical correlation for calculation of corrosion kinetics has been derived. (authors)

  12. Development of computational methods of design by analysis for pressure vessel components

    International Nuclear Information System (INIS)

    Bao Shiyi; Zhou Yu; He Shuyan; Wu Honglin

    2005-01-01

    Stress classification is not only one of key steps when pressure vessel component is designed by analysis, but also a difficulty which puzzles engineers and designers at all times. At present, for calculating and categorizing the stress field of pressure vessel components, there are several computation methods of design by analysis such as Stress Equivalent Linearization, Two-Step Approach, Primary Structure method, Elastic Compensation method, GLOSS R-Node method and so on, that are developed and applied. Moreover, ASME code also gives an inelastic method of design by analysis for limiting gross plastic deformation only. When pressure vessel components design by analysis, sometimes there are huge differences between the calculating results for using different calculating and analysis methods mentioned above. As consequence, this is the main reason that affects wide application of design by analysis approach. Recently, a new approach, presented in the new proposal of a European Standard, CEN's unfired pressure vessel standard EN 13445-3, tries to avoid problems of stress classification by analyzing pressure vessel structure's various failure mechanisms directly based on elastic-plastic theory. In this paper, some stress classification methods mentioned above, are described briefly. And the computational methods cited in the European pressure vessel standard, such as Deviatoric Map, and nonlinear analysis methods (plastic analysis and limit analysis), are depicted compendiously. Furthermore, the characteristics of computational methods of design by analysis are summarized for selecting the proper computational method when design pressure vessel component by analysis. (authors)

  13. NEAR REAL-TIME AUTOMATIC MARINE VESSEL DETECTION ON OPTICAL SATELLITE IMAGES

    Directory of Open Access Journals (Sweden)

    G. Máttyus

    2013-05-01

    Full Text Available Vessel monitoring and surveillance is important for maritime safety and security, environment protection and border control. Ship monitoring systems based on Synthetic-aperture Radar (SAR satellite images are operational. On SAR images the ships made of metal with sharp edges appear as bright dots and edges, therefore they can be well distinguished from the water. Since the radar is independent from the sun light and can acquire images also by cloudy weather and rain, it provides a reliable service. Vessel detection from spaceborne optical images (VDSOI can extend the SAR based systems by providing more frequent revisit times and overcoming some drawbacks of the SAR images (e.g. lower spatial resolution, difficult human interpretation. Optical satellite images (OSI can have a higher spatial resolution thus enabling the detection of smaller vessels and enhancing the vessel type classification. The human interpretation of an optical image is also easier than as of SAR image. In this paper I present a rapid automatic vessel detection method which uses pattern recognition methods, originally developed in the computer vision field. In the first step I train a binary classifier from image samples of vessels and background. The classifier uses simple features which can be calculated very fast. For the detection the classifier is slided along the image in various directions and scales. The detector has a cascade structure which rejects most of the background in the early stages which leads to faster execution. The detections are grouped together to avoid multiple detections. Finally the position, size(i.e. length and width and heading of the vessels is extracted from the contours of the vessel. The presented method is parallelized, thus it runs fast (in minutes for 16000 × 16000 pixels image on a multicore computer, enabling near real-time applications, e.g. one hour from image acquisition to end user.

  14. Near Real-Time Automatic Marine Vessel Detection on Optical Satellite Images

    Science.gov (United States)

    Máttyus, G.

    2013-05-01

    Vessel monitoring and surveillance is important for maritime safety and security, environment protection and border control. Ship monitoring systems based on Synthetic-aperture Radar (SAR) satellite images are operational. On SAR images the ships made of metal with sharp edges appear as bright dots and edges, therefore they can be well distinguished from the water. Since the radar is independent from the sun light and can acquire images also by cloudy weather and rain, it provides a reliable service. Vessel detection from spaceborne optical images (VDSOI) can extend the SAR based systems by providing more frequent revisit times and overcoming some drawbacks of the SAR images (e.g. lower spatial resolution, difficult human interpretation). Optical satellite images (OSI) can have a higher spatial resolution thus enabling the detection of smaller vessels and enhancing the vessel type classification. The human interpretation of an optical image is also easier than as of SAR image. In this paper I present a rapid automatic vessel detection method which uses pattern recognition methods, originally developed in the computer vision field. In the first step I train a binary classifier from image samples of vessels and background. The classifier uses simple features which can be calculated very fast. For the detection the classifier is slided along the image in various directions and scales. The detector has a cascade structure which rejects most of the background in the early stages which leads to faster execution. The detections are grouped together to avoid multiple detections. Finally the position, size(i.e. length and width) and heading of the vessels is extracted from the contours of the vessel. The presented method is parallelized, thus it runs fast (in minutes for 16000 × 16000 pixels image) on a multicore computer, enabling near real-time applications, e.g. one hour from image acquisition to end user.

  15. What is cerebral small vessel disease?

    International Nuclear Information System (INIS)

    Onodera, Osamu

    2011-01-01

    An accumulating amount of evidence suggests that the white matter hyperintensities on T 2 weighted brain magnetic resonance imaging predict an increased risk of dementia and gait disturbance. This state has been proposed as cerebral small vessel disease, including leukoaraiosis, Binswanger's disease, lacunar stroke and cerebral microbleeds. However, the concept of cerebral small vessel disease is still obscure. To understand the cerebral small vessel disease, the precise structure and function of cerebral small vessels must be clarified. Cerebral small vessels include several different arteries which have different anatomical structures and functions. Important functions of the cerebral small vessels are blood-brain barrier and perivasucular drainage of interstitial fluid from the brain parenchyma. Cerebral capillaries and glial endfeet, take an important role for these functions. However, the previous pathological investigations on cerebral small vessels have focused on larger arteries than capillaries. Therefore little is known about the pathology of capillaries in small vessel disease. The recent discoveries of genes which cause the cerebral small vessel disease indicate that the cerebral small vessel diseases are caused by a distinct molecular mechanism. One of the pathological findings in hereditary cerebral small vessel disease is the loss of smooth muscle cells, which is an also well-recognized finding in sporadic cerebral small vessel disease. Since pericytes have similar character with the smooth muscle cells, the pericytes should be investigated in these disorders. In addition, the loss of smooth muscle cells may result in dysfunction of drainage of interstitial fluid from capillaries. The precise correlation between the loss of smooth muscle cells and white matter disease is still unknown. However, the function that is specific to cerebral small vessel may be associated with the pathogenesis of cerebral small vessel disease. (author)

  16. Development of the Simulation Program for the In-Vessel Fuel Handling System of Double Rotating Plug Type

    International Nuclear Information System (INIS)

    Kim, S. H.; Kim, J. B.

    2011-01-01

    In-vessel fuel handling machines are the main equipment of the in-vessel fuel handling system, which can move the core assembly inside the reactor vessel along with the rotating plug during refueling. The in vessel fuel handling machines for an advanced sodium cooled fast reactor(SFR) demonstration plant are composed of a direct lift machine(DM) and a fixed arm machine(FM). These machines should be able to access all areas above the reactor core by means of the rotating combination of double rotating plugs. Thus, in the in vessel fuel handling system of the double rotating plug type, it is necessary to decide the rotating plug size and evaluate the accessibility of in-vessel fuel handling machines in given core configuration. In this study, the simulation program based on LABVIEW which can effectively perform the arrangement design of the in vessel fuel handling system and simulate the rotating plug motion was developed. Fig. 1 shows the flow chart of the simulation program

  17. Sodium steam generator within which are inlet and outlet ducts with pipe bundles in vessel

    International Nuclear Information System (INIS)

    1980-01-01

    The sodium steam generator with internal flow ducts for inlet and outlet to a vessel are provided as pipe bundles in the form of helically wound concentric layers terminating in inlet and outlet connections with chambers, characterised in that within the vessel, the pipe pieces which are connected to the pipe windings with the said vessel are arranged in substantially radially aligned rows so that each row measured in the circumferential direction at least on one side is at a spacing from the following row sufficiently large that between the rows or groups of rows an open sector is provided. (G.C.)

  18. Nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Blackstone, E.G.; Lofy, R.A.; Williams, L.P.

    1979-01-01

    Apparatus for the in situ inspection of a nuclear reactor vessel to detect the location and character of flaws in the walls of the vessel, in the welds joining the various sections of the vessel, in the welds joining attachments such as nozzles, elbows and the like to the reactor vessel and in such attachments wherein an inspection head carrying one or more ultrasonic transducers follows predetermined paths in scanning the various reactor sections, welds and attachments

  19. Flexible Composite-Material Pressure Vessel

    Science.gov (United States)

    Brown, Glen; Haggard, Roy; Harris, Paul A.

    2003-01-01

    A proposed lightweight pressure vessel would be made of a composite of high-tenacity continuous fibers and a flexible matrix material. The flexibility of this pressure vessel would render it (1) compactly stowable for transport and (2) more able to withstand impacts, relative to lightweight pressure vessels made of rigid composite materials. The vessel would be designed as a structural shell wherein the fibers would be predominantly bias-oriented, the orientations being optimized to make the fibers bear the tensile loads in the structure. Such efficient use of tension-bearing fibers would minimize or eliminate the need for stitching and fill (weft) fibers for strength. The vessel could be fabricated by techniques adapted from filament winding of prior composite-material vessels, perhaps in conjunction with the use of dry film adhesives. In addition to the high-bias main-body substructure described above, the vessel would include a low-bias end substructure to complete coverage and react peak loads. Axial elements would be overlaid to contain damage and to control fiber orientation around side openings. Fiber ring structures would be used as interfaces for connection to ancillary hardware.

  20. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  1. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  2. Application of directional solidification ingot (LSD) in forging of PWR reactor vessel heads

    International Nuclear Information System (INIS)

    Benhamou, C.; Poitrault, I.

    1985-09-01

    Creusot-Loire Industrie uses this type of ingot for manufacture of Framatome 1300 and 1450 MW 4-loop PWR reactor vessel heads. This type of ingot offers a number advantages: improved internal soundness; greater chemical, structural and mechanical homogeneity of the finished part; simplified forging process. After a brief description of the pouring and solidification processes, this paper presents an analysis of the results of examinations performed on the prototype forging, as well as review of results obtained during industrial fabrication of dished heads from LSD ingots. The advantages of the LSD ingot over conventional ingots are discussed in conclusion

  3. Development of PWR pressure vessel steels

    International Nuclear Information System (INIS)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed

  4. Development of PWR pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed.

  5. Clay Corner: Recreating Chinese Bronze Vessels.

    Science.gov (United States)

    Gamble, Harriet

    1998-01-01

    Presents a lesson where students make faux Chinese bronze vessels through slab or coil clay construction after they learn about the history, function, and design of these vessels. Utilizes a variety of glaze finishes in order to give the vessels an aged look. Gives detailed guidelines for creating the vessels. (CMK)

  6. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  7. Serial Metabolome Changes in a Prospective Cohort of Subjects with Influenza Viral Infection and Comparison with Dengue Fever.

    Science.gov (United States)

    Cui, Liang; Fang, Jinling; Ooi, Eng Eong; Lee, Yie Hou

    2017-07-07

    Influenza virus infection (IVI) and dengue virus infection (DVI) are major public health threats. Between IVI and DVI, clinical symptoms can be overlapping yet infection-specific, but host metabolome changes are not well-described. Untargeted metabolomics and targeted oxylipinomic analyses were performed on sera serially collected at three phases of infection from a prospective cohort study of adult subjects with either H3N2 influenza infection or dengue fever. Untargeted metabolomics identified 26 differential metabolites, and major perturbed pathways included purine metabolism, fatty acid biosynthesis and β-oxidation, tryptophan metabolism, phospholipid catabolism, and steroid hormone pathway. Alterations in eight oxylipins were associated with the early symptomatic phase of H3N2 flu infection, were mostly arachidonic acid-derived, and were enriched in the lipoxygenase pathway. There was significant overlap in metabolome profiles in both infections. However, differences specific to IVI and DVI were observed. DVI specifically attenuated metabolites including serotonin, bile acids and biliverdin. Additionally, metabolome changes were more persistent in IVI in which metabolites such as hypoxanthine, inosine, and xanthine of the purine metabolism pathway remained significantly elevated at 21-27 days after fever onset. This study revealed the dynamic metabolome changes in IVI subjects and provided biochemical insights on host physiological similarities and differences between IVI and DVI.

  8. Smooth muscle cell recruitment to lymphatic vessels requires PDGFB and impacts vessel size but not identity.

    Science.gov (United States)

    Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija; Jakobsson, Lars

    2017-10-01

    Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. © 2017. Published by The Company of Biologists Ltd.

  9. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  10. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  11. PWR vessel flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kennedy, E.L.; Foulds, J.R.; Kinsman, K.M.

    1990-01-01

    This paper reports on PWR pressure vessels which operate under NRC rules and regulatory guides intended to prevent failure of the vessels. Plants failing to meet the operating criteria specified under these rules and regulations are required to analytically demonstrate fitness for service in order to continue operation. The initial flaw size or distribution of initial vessel flaws is a key input to the required vessel integrity analyses. However, the flaw distribution assumed in the development of the NRC Regulations and recommended for the plant specific analyses is potentially over-conservative. This is because the distribution is based on the limited amount of vessel inspection data available at the time the criteria were being developed and does not take full advantage of the more recent and reliable domestic vessel inspection results. The U.S. Department of Energy is funding an effort through Sandia National Laboratories to investigate the possibility of developing a new flaw distribution based on the increased amount and improved reliability of domestic vessel inspection data. Results of Phase I of the program indicate that state-of-the-art NDE systems' capabilities are sufficient for development of a new flaw distribution that could ultimately provide life extension benefits over the presently required operating practice

  12. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7

    International Nuclear Information System (INIS)

    Merkle, J.G.; Robinson, G.C.; Holz, P.P.; Smith, J.E.; Bryan, R.H.

    1976-08-01

    The test of intermediate test vessel V-7 was a crack-initiation fracture test of a 152-mm-thick (6-in.), 990-mm-OD (39-in.) vessel of ASTM A533, grade B, class 1 steel plate with a sharp outside surface flaw 457 mm (18 in.) long and about 135 mm (5.3 in.) deep. The vessel was heated to 91 0 C (196 0 F) and pressurized hydraulically until leakage through the flaw terminated the test at a peak pressure of 147 MPa (21,350 psi). Fracture toughness data obtained by testing precracked Charpy-V and compact-tension specimens machined from a prolongation of the cylindrical test shell were used in pretest analyses of the flawed vessel. The vessel, as expected, did not burst. Upon depressurization, the ruptured ligament closed so as to maintain static pressure without leakage at about 129 MPa

  13. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  14. Earthquake-proof supporting structure in reactor vessel

    International Nuclear Information System (INIS)

    Sakurai, Akio; Sekine, Katsuhisa; Madokoro, Manabu; Katoono, Shin-ichi; Konno, Mutsuo; Suzuki, Takuro.

    1990-01-01

    Conventional earthquake-proof structure comprises a vessel vibration stopper integrated to a reactor vessel, powder for restricting the horizontal displacements, a safety vessel surrounds the outer periphery of the reactor vessel and a safety vessel vibration stopper integrated therewith, which are fixed to buildings. However, there was a problem that a great amount of stresses are generated in the base of the reactor vessel vibration stopper due to reaction of the powders which restrict thermal expansion. In order to remarkably reduce the reaction of the powers, powders are charged into a spaces formed between each of the reactor vessel vibration stopper, the safety vessel vibration stopper and the flexible member disposed between them. According to this constitution, the reactor vessel vibration stopper does not undergo a great reaction of the powers upon thermal expansion of the reactor vessel to moderate the generated stresses, maintain the strength and provide earthquake-proof supporting function. (N.H.)

  15. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  16. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  17. Radioactive waste processing vessel

    International Nuclear Information System (INIS)

    Hayashi, Masaru; Suzuki, Osamu; Ishizaki, Kanjiro.

    1987-01-01

    Purpose: To obtain a vessel of a reduced weight and with no external leaching of radioactive materials. Constitution: The vessel main body is constituted, for example, with light weight concretes or foamed concretes, particularly, foamed concretes containing fine closed bubbles in the inside. Then, layers having dense texture made of synthetic resin such as polystylene, vinylchloride resin, etc. or metal plate such as stainless plate are integrally disposed to the inner surface of the vessel main body. The cover member also has the same structure. (Sekiya, K.)

  18. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  19. Clinical results of single-vessel versus multiple-vessel infrapopliteal intervention

    OpenAIRE

    Darling, Jeremy; McCallum, John C.; Soden, Peter A.; Hon, J.J. (John J.); Guzman, R.J. (Raul J.); Wyers, M.C. (Mark C.); Verhagen, Hence; Schermerhorn, Marc

    2016-01-01

    textabstractObjective The effects of concomitant endovascular interventions on multiple infrapopliteal vessels are not well known, and the short-term and long-term sequelae of such procedures have not been reported. Methods From 2004 to 2014, 673 limbs in 528 patients underwent an infrapopliteal endovascular intervention for tissue loss (77%), rest pain (13%), stenosis of a previously treated vessel (5%), acute limb ischemia (3%), or claudication (2%). Outcomes included wound healing, RAS eve...

  20. Molten material-containing vessel

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko

    1998-01-01

    The molten material-containing vessel of the present invention comprises a vessel main body having an entrance opened at the upper end, a lid for closing the entrance, an outer tube having an upper end disposed at the lower surface of the lid, extended downwardly and having an closed lower end and an inner tube disposed coaxially with the outer tube. When a molten material is charged from the entrance to the inside of the vessel main body of the molten material-containing vessel and the entrance is closed by the lid, the outer tube and the inner tube are buried in the molten material in the vessel main body, accordingly, a fluid having its temperature elevated by absorption of the heat of the molten material rises along the inner circumferential surface of the outer tube, abuts against the lower surface of the lid and cooled by exchanging heat with the lid and forms a circulating flow. Since the heat in the molten material is continuously absorbed by the fluid, transferred to the lid and released from the lid to the atmospheric air, heat releasing efficiency can be improved compared with conventional cases. (N.H.)

  1. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  2. Baffle-former arrangement for nuclear reactor vessel internals

    International Nuclear Information System (INIS)

    Machado, O.J.; Berringer, R.T.

    1978-01-01

    A baffle-former arrangement for the reactor vessel internals of a nuclear reactor is described. The arrangement includes positioning of formers at the same elevations as the fuel assembly grids, and positioning flow holes in the baffle plates directly beneath selected former grid elevations. The arrangement reduces detrimental cross flows, maintains proper core barrel and baffle temperatures, and alleviates the potential of overpressurization within the baffle-former assembly under assumed major accident conditions

  3. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    Science.gov (United States)

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, Psampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  4. Motions of deformable inclusions in a horizontally oscillating vessel with a compressible fluid

    DEFF Research Database (Denmark)

    Demidov, I.V.; Sorokin, Vladislav

    2016-01-01

    The paper is concerned with the analysis of rigid particle and compressible gas bubble motion in a horizontally oscillating vessel with a compressible fluid. A nonlinear differential equation describing motion of inclusions with respect to the vessel is derived and solved by the method of direct...... of the bubbles which are affected by the negligible vibrational force is found. Also an approximate expression has been obtained for the average velocity of bubble׳s motion in the fluid; relationship between this velocity and bubble radius and vibration parameters has been revealed. A simple physical explanation...

  5. Design for an MHD power plant as a prime mover for a Naval Vessel

    International Nuclear Information System (INIS)

    Paluszek, M.A.

    1981-01-01

    A Magnetohydrodynamic Power Plant, designed to be the prime mover for a Naval Vessel, is presented. The system is an open cycle, fossil fueled, subsonic MHD Faraday generator with directly fired air preheaters. A superconducting electric transmission drives the propellers and a standard naval steam plant is used as a bottoming cycle. The increased overall efficiency achievable with this plant allows a lighter, smaller volume ship to accommodate the same payload and reduces the overall fuel cost of the vessel

  6. Radiation embrittlement of PWR vessel supports

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Robinson, G.C.; Pennell, W.E.; Nanstad, R.K.

    1989-01-01

    Several studies pertaining to radiation damage of PWR vessel supports were conducted between 1978 and 1987. During this period, apparently there was no reason to believe that low-temperature (<100 degree C) MTR embrittlement data were not appropriate for evaluating embrittlement of PWR vessel supports. However, late in 1986, data from the High Flux Isotope Reactor (HFIR) vessel surveillance program indicated that the embrittlement rates of the several HFIR vessel materials (A212-B, A350-LF3, A105-II) were substantially greater than anticipated on the basis of MTR data. Further evaluation of the HFIR data suggested that a fluence-rate effect was responsible for the apparent discrepancy, and shortly thereafter it became apparent that this rate effect was applicable to the evaluation of LWR vessel supports. As a result, the Nuclear Regulatory Commission (NRC) requested that the Oak Ridge National Laboratory (ORNL) evaluate the impact of the apparent embrittlement rate effect on the integrity of light-water-reactor (LWR) vessel supports. The purpose of the study was to provide an indication of whether the integrity of reactor vessel supports is likely to be challenged by radiation-induced embrittlement. The scope of the evaluation included correlation of the HFIR data for application to the evaluation of LWR vessel supports; a survey and cursory evaluation of all US LWR vessel support designs, selection of two plants for specific-plant evaluation, and a specific-plant evaluation of both plants to determine critical flaw sizes for their vessel supports. 19 refs., 8 figs., 2 tabs

  7. Prestressed cast iron pressure vessels as burst-proof pressure vessels for innovative nuclear applications

    International Nuclear Information System (INIS)

    Froehling, W.; Boettcher, A.; Bounin, D.; Steinwarz, W.; Geiss, M.; Trauth, M.

    2000-01-01

    The amendment to the German Atomic Energy Act from July 28, 1994 requires that events 'whose occurrence is practically excluded by the measures against damages', i.e. events of the category residual risk, must not necessitate far reaching protective measures outside the plant. For a conventional reactor pressure vessel, the residual risk consists in the very small probability of a catastrophic failure (formation of a large fracture opening, bursting of the vessel). With a prestressed cast iron vessel (PCIV), the formation of a large fracture opening or bursting of the vessel, respectively, is impossible due to its design properties. Against this background the possibility of the use of this type of pressure vessel for lightwater reactors has been studied in the frame of a 'Working Group for Innovative Nuclear Technology', founded by different research institutes and industrial companies. Furthermore, it has been studied whether the use of the PCIV support the realization of a corecatcher system. The results are presented in this report. Already many years earlier, Siempelkamp has performed industrial development and Forschungszentrum Juelich related experimental and theoretical safety research for the PCIV as an innovative, bust-proof pressure vessel concept. This development of the PCIV as well as its safety properties are also presented in a conclusive manner. (orig.) [de

  8. 46 CFR 4.03-40 - Public vessels.

    Science.gov (United States)

    2010-10-01

    ... INVESTIGATIONS Definitions § 4.03-40 Public vessels. Public vessel means a vessel that— (a) Is owned, or demise... Department (except a vessel operated by the Coast Guard or Saint Lawrence Seaway Development Corporation...

  9. Reactor containment vessel

    International Nuclear Information System (INIS)

    Ochiai, Kanehiro; Hayagumo, Sunao; Morikawa, Matsuo.

    1981-01-01

    Purpose: To safety and simplify the structure in a reactor containment vessel. Constitution: Steam flow channels with steam jetting ports communicating to coolants are provided between a communication channel and coolants in a pressure suppression chamber. Upon loss of coolant accidents, pressure in a dry well will increase, then force downwards water in an annulus portion and further flow out the water through steam jetting ports into a suppression pool. Thus, the steam flow channel is filled with steams or airs present in the dry well, which are released through the steam jetting ports into the pressure suppression chamber. Even though water is violently vibrated owing to the upward movement of air bubbles and condensation of steam bubbles, the annular portion and the steam jetting ports are filled with steams or the like, direct dynamic loads onto the structures such as communication channels can be avoided. (J.P.N.)

  10. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  11. Nuclear reactor pressure vessel flaw distribution development

    International Nuclear Information System (INIS)

    Kennedy, E.L.; Foulds, J.R.; Basin, S.L.

    1991-12-01

    Previous attempts to develop flaw distributions for probabilistic fracture mechanics analyses of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all PWR vessels. In contrast, this report describes (1) a new flaw distribution development analytic methodology that can be applied to the analysis of vessel-specific inservice inspection (ISI) data, and (2) results of the application of the methodology to the analysis of flaw data for each vessel case (ISI data on three PWR vessels and laboratory inspection data on sections of the Midland reactor vessel). Results of this study show significant variation among the flaw distributions derived from the various data sets analyzed, strongly suggesting than a vessel-specific flaw distribution (for vessel integrity prediction under pressurized thermal shock) is preferred over a ''generic'' distribution. In addition, quantitative inspection system flaw sizing accuracy requirements have been identified for developing a flaw distribution from vessel ISI data. The new flaw data analysis methodology also permits quantifying the reliability of the flaw distribution estimate. Included in the report are identified needs for further development of several aspects of ISI data acquisition and vessel integrity prediction practice

  12. Research Vessel R/V Sikuliaq: Joining the UNOLS Fleet in 2014

    Science.gov (United States)

    Whitledge, T. E.

    2013-12-01

    The global class research vessel R/V Sikuliaq is being constructed on behalf of the NSF to support future scientific studies in high latitude waters. The 261 foot vessel will be capable of breaking 2.5 foot thick ice at 2 knots with an endurance of 45 days at sea and cruising at 11 knots. The R/V Sikuliaq has a beam of 52 feet and a draft of 18.9 feet that will carry 26 scientists and a crew of 20. Berthing accommodations are a combination of single/double rooms with one stateroom and the common areas of the vessel are designed for ADA access and accommodations. The total laboratory space (main, analytical, electronics, wet, upper, and Baltic room are 2100 square feet. The 4360 square foot working deck that is approximately 70 feet in length will accommodate 2-4 vans and multiple science operations. The vessel design strives to have the lowest possible environmental impact, including a low underwater-radiated noise signature. The science systems are prescribed to be state-of-the-art for bottom mapping, over-the-side 'hands free' gear handling, broad band communications and scientific walk-in freezer and environmental chamber. More details and photos of the construction progress are available on the website at www.sfos.uaf.edu/arrv. The vessel was launched in October 2012 and delivery to the University of Alaska Fairbanks is scheduled for November 2013. Scientific operations following testing and science sea trials are planned to start in summer of 2014. Questions about the science systems or vessel capabilities should be directed to Terry Whitledge (terry@ims.uaf.edu).

  13. Targeting Therapy Resistant Tumor Vessels

    Science.gov (United States)

    2008-08-01

    Morris LS. Hysterectomy vs. resectoscopic endometrial ablation for the control of abnormal uterine bleeding . A cost-comparative study. J Reprod Med 1994;39...after the antibody treatment contain a pericyte coat, vessel architecture is normal, the diameter of the vessels is smaller (dilated, abnormal vessels...involvement of proteases from inflammatory mast cells and functionally abnormal (Carmeliet and Jain, 2000; Pasqualini (Coussens et al., 1999) and other bone

  14. Pressurized wet digestion in open vessels (T11)

    International Nuclear Information System (INIS)

    Kettisch, P.; Maichin, P.; Zischka, M.; Knapp, G.

    2002-01-01

    Full text: Pressurized wet digestion in closed vessels, microwave assisted or with conventional conductive heating, is the most important sample preparation technique for digestion or leaching procedures in element analysis. In comparison to open vessel digestion closed vessel digestion methods have many advantages, but there is one disadvantage - complex and expensive vessel designs. A new technique - pressurized wet digestion in open vessels - combine the advantages of closed vessel sample digestion with the application of simple and cheap open vessels made of quartz or PFA. The vessels are placed in a high pressure Asher HPA, which is adapted with a Teflon liner and filled partly with water. The analytical results with 30 ml quartz vessels, 22 ml PFA vessels and 1.5 ml PIA auto sampler cups will be shown. In principle every dimensions of vessels can be used. The vessels are loaded with sample material (max. 1.5 g with quartz vessels, max. 0.5 g with PFA vessels and 50 mg with auto sampler cups) and digestion reagent. Afterwards the vessels are simply covered with PTFE stoppers and not sealed. The vessels are transferred into a special adapted HPA and digested at temperatures up to 270 o C. The digestion time is 90 min. and cooling down to room temperature 30 min. The analytical results of CRM's are within the certified values and no cross contamination and losses of volatile elements could be observed. (author)

  15. Flaw distribution development from vessel ISI data

    International Nuclear Information System (INIS)

    Foulds, J.R.; Kennedy, E.L.; Basin, S.L.; Rosinski, S.T.

    1991-01-01

    Previous attempts to develop flaw distributions for use in the structural integrity evaluation of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all vessels. In contrast, this paper describes the analysis of vessel-specific in-service inspection (ISI) data for the development of a flaw distribution reliably representative of the condition of the particular vessel inspected. The application of the methodology may be extended to other vessels, but has been primarily developed for PWR reactor vessels. For this study, the flaw data analyzed included data obtained from three recently performed PWR vessel ISIs and from laboratory inspection of selected weldment sections of the Midland reactor vessel. The variability in both the character of the reviewed data (size range of flaws, number of flaws) and the UT (ultrasonic test) inspection system performance identified a need for analyzing the inspection results on a vessel-, or data set-specific basis. For this purpose, traditional histogram-based methods were inadequate, and a new methodology that can accept a very small number of flaws (typical of vessel-specific ISI results) and that includes consideration of inspection system flaw detection reliability, flaw sizing accuracy and flaw detection threshold, was developed. Results of the application of the methodology to each of the four PWR reactor vessel cases studied are presented and discussed

  16. Seals for sealing a pressure vessel such as a nuclear reactor vessel or the like

    International Nuclear Information System (INIS)

    Bruns, H.J.; Huelsermann, K.H.

    1975-01-01

    A description is given of seals for sealing a pressure vessel such as a nuclear reactor vessel, steam boiler vessel, or any other vessel which is desirably sealed against pressure of the type including a housing and a housing closure that present opposed vertical sealing surfaces which define the sides of a channel. The seals of the present invention comprise at least one sealing member disposed in the channel, having at least one stop face, a base portion and two shank portions extending from the base portion to form a groove-like recess. The shank portions are provided with sealing surfaces arranged to mate with the opposed vertical pressure vessel sealing surfaces. A shank-spreading wedge element also disposed in the channel has at least one stop face and is engaged in the groove-like recess with the sealing member and wedge element stop face adjacent to each other

  17. Proposal of Ex-Vessel dosimetry for pressure vessel Atucha II

    International Nuclear Information System (INIS)

    Chiaraviglio, N.; Bazzana, S.

    2013-01-01

    Nuclear reactor dosimetry has the purpose of guarantee that changes in material mechanical properties of critical materials do not compromise the reactor safety. In PWR in which the top of the reactor vessel is open once a year, is possible to use Charpy specimens to measure the change in mechanical properties. Atucha II nuclear power plant is a reactor with on-line refueling so there is no access to the inside of the pressure vessel. Because of this, ex-vessel dosimetry must be performed and mechanical properties changes must be inferred from radiation damage estimations. This damage can be calculated using displacement per atom cross sections and a transport code such as MCNP. To increase results reliability it is proposed to make a neutron spectrum unfolding using activation dosimeters irradiated during one operation cycle of the power plant. In this work we present a dosimetry proposal for such end, made in base of unfolding procedures and experimental background. (author) [es

  18. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  19. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  20. Semiautomated segmentation of blood vessels using ellipse-overlap criteria: Method and comparison to manual editing

    International Nuclear Information System (INIS)

    Shiffman, Smadar; Rubin, Geoffrey D.; Schraedley-Desmond, Pamela; Napel, Sandy

    2003-01-01

    Two-dimensional intensity-based methods for the segmentation of blood vessels from computed-tomography-angiography data often result in spurious segments that originate from other objects whose intensity distributions overlap with those of the vessels. When segmented images include spurious segments, additional methods are required to select segments that belong to the target vessels. We describe a method that allows experts to select vessel segments from sequences of segmented images with little effort. Our method uses ellipse-overlap criteria to differentiate between segments that belong to different objects and are separated in plane but are connected in the through-plane direction. To validate our method, we used it to extract vessel regions from volumes that were segmented via analysis of isolabel-contour maps, and showed that the difference between the results of our method and manually-edited results was within inter-expert variability. Although the total editing duration for our method, which included user-interaction and computer processing, exceeded that of manual editing, the extent of user interaction required for our method was about a fifth of that required for manual editing

  1. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  2. Calculation of a thermostressed state for drum-separator vessels in transient regimes

    International Nuclear Information System (INIS)

    Il'in, Yu.V.; Kazakova, T.Yu.; Parafilo, L.M.; Shcherbakov, S.I.

    1979-01-01

    The temperature regime and stressed state of the drum-separator vessel in the transient regime with alternating pressure and water level are investigated using calculations. The temperature fields are calculated by the alternating directions method. Stresses and deformations are calculated by the method of finite elements. The stressed state of the vessel is determined for a series of fixed time moments tausub(i), when the T(tausub(i), r, phi) temperature distribution and P(tausub(i)) internal pressure are known. The methods described are used while developing the calculation program for the temperatures and stressed state (FORTRAN, EC-1050). Given are the calculation results obtained using these programs for the processes following the safety system response at the first block of the Bilibinsk NPP and the processes of power regulation in the ''Sever-2'' facility. The comparison of the obtained calculated curves with the experimental data confirms fitness of the proposed calculated scheme for description of the real processes taking place in the drum-separator vessels in the transient regimes. It is emphasized that the given scheme of solution of the equations describing a thermostressed state of the drum-separator vessels can be used while estimating their operation capacity

  3. Expanded Fermilab pressure vessel directory program

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect.

  4. Expanded Fermilab pressure vessel directory program

    International Nuclear Information System (INIS)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect

  5. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  6. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    International Nuclear Information System (INIS)

    Ahn, K.I.; Kim, B.S.; Kim, D.H.

    2001-01-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  7. Ex-vessel Fish Price Database: Disaggregating Prices for Low-Priced Species from Reduction Fisheries

    Directory of Open Access Journals (Sweden)

    Travis C. Tai

    2017-11-01

    Full Text Available Ex-vessel fish prices are essential for comprehensive fisheries management and socioeconomic analyses for fisheries science. In this paper, we reconstructed a global ex-vessel price database with the following areas of improvement: (1 compiling reported prices explicitly listed as “for reduction to fishmeal and fish oil” to estimate prices separately for catches destined for fishmeal and fish oil production, and other non-direct human consumption purposes; (2 including 95% confidence limit estimates for each price estimation; and (3 increasing the number of input data and the number of price estimates to match the reconstructed Sea Around Us catch database. Our primary focus was to address this first area of improvement as ex-vessel prices for catches destined for non-direct human consumption purposes were substantially overestimated, notably in countries with large reduction fisheries. For example in Peru, 2010 landed values were estimated as 3.8 billion real 2010 USD when using separate prices for reduction fisheries, compared with 5.8 billion using previous methods with only one price for all end-products. This update of the price database has significant global and country-specific impacts on fisheries price and landed value trends over time.

  8. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Kurita, Gen-ichi; Onozuka, Masaki; Suzuki, Masaru.

    1997-01-01

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and γ rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  9. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Kurita, Gen-ichi [Japan Atomic Energy Research Inst., Tokyo (Japan); Onozuka, Masaki; Suzuki, Masaru

    1997-07-31

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and {gamma} rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  10. Reliability analysis of reactor pressure vessel intensity

    International Nuclear Information System (INIS)

    Zheng Liangang; Lu Yongbo

    2012-01-01

    This paper performs the reliability analysis of reactor pressure vessel (RPV) with ANSYS. The analysis method include direct Monte Carlo Simulation method, Latin Hypercube Sampling, central composite design and Box-Behnken Matrix design. The RPV integrity reliability under given input condition is proposed. The result shows that the effects on the RPV base material reliability are internal press, allowable basic stress and elasticity modulus of base material in descending order, and the effects on the bolt reliability are allowable basic stress of bolt material, preload of bolt and internal press in descending order. (authors)

  11. Tempest in a vessel

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-01-01

    As the ASN made some statements about anomalies of carbon content in the EPR vessel bottom and top, the author recalls and comments some technical issues to better understand the information published on this topic. He notably addresses the role of the vessel, briefly indicates its operating conditions, shape and structure, and mechanical components for the top, its material and mechanical properties, and test samples used to assess mechanical properties. He also comments the phenomenon of radio-induced embrittlement, the vessel manufacturing process, and evokes the applicable regulations. He quotes and comments statements made by the ASN and Areva which evoke further assessments of the concerned components

  12. Automatic Vessel Segmentation on Retinal Images

    Institute of Scientific and Technical Information of China (English)

    Chun-Yuan Yu; Chia-Jen Chang; Yen-Ju Yao; Shyr-Shen Yu

    2014-01-01

    Several features of retinal vessels can be used to monitor the progression of diseases. Changes in vascular structures, for example, vessel caliber, branching angle, and tortuosity, are portents of many diseases such as diabetic retinopathy and arterial hyper-tension. This paper proposes an automatic retinal vessel segmentation method based on morphological closing and multi-scale line detection. First, an illumination correction is performed on the green band retinal image. Next, the morphological closing and subtraction processing are applied to obtain the crude retinal vessel image. Then, the multi-scale line detection is used to fine the vessel image. Finally, the binary vasculature is extracted by the Otsu algorithm. In this paper, for improving the drawbacks of multi-scale line detection, only the line detectors at 4 scales are used. The experimental results show that the accuracy is 0.939 for DRIVE (digital retinal images for vessel extraction) retinal database, which is much better than other methods.

  13. The evolution and structural design of prestressed concrete pressure vessels

    International Nuclear Information System (INIS)

    Hannah, I.W.

    1978-01-01

    The introduction of the prestressed concrete pressure vessel to contain the main gas coolant circuit of nuclear reactors has marked a major step forward. This chapter traces the evolution and development of the PCPV, and lists the principal parameters adopted. Current design and loading standards are discussed in relation to the two main limit states of serviceability and safety. Prestressed concrete pressure vessel analysis has called for very extensive adaptation and expansion of conventional finite element and finite difference methods in order to deal with the elevated temperature of operation, together with extensive concrete testing at temperature and under multi-directional stressing. These new methods and extra data are being adopted in prestressed applications in other fields and may well prove to be of much wider significance than is presently appreciated. (author)

  14. 77 FR 8177 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Pot Gear in the...

    Science.gov (United States)

    2012-02-14

    ... Using Pot Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National Marine Fisheries...; closure. SUMMARY: NMFS is prohibiting directed fishing for Pacific cod by vessels using pot gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to vessels using pot gear in...

  15. 77 FR 14305 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Jig Gear in the...

    Science.gov (United States)

    2012-03-09

    ... Using Jig Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National Marine Fisheries...; closure. SUMMARY: NMFS is prohibiting directed fishing for Pacific cod by vessels using jig gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to vessels using jig gear in...

  16. 77 FR 6683 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Pot Gear in the...

    Science.gov (United States)

    2012-02-09

    ... Using Pot Gear in the Western Regulatory Area of the Gulf of Alaska AGENCY: National Marine Fisheries...; closure. SUMMARY: NMFS is prohibiting directed fishing for Pacific cod by vessels using pot gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to vessels using pot gear in...

  17. Nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    This patent describes an improved liquid metal nuclear reactor construction comprising: (a) a nuclear reactor core having a bottom platform support structure; (b) a reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core; (c) a containment structure surrounding the reactor vessel and having a sidewall spaced outwardly from the reactor vessel side wall and having a base mat spaced below the reactor vessel bottom end wall; (d) a central small diameter post anchored to the containment structure base mat and extending upwardly to the reactor vessel to axially fix the bottom end wall of the reactor vessel and provide a center column support for the lower end of the reactor core; (e) annular support structure disposed in the reactor vessel on the bottom end wall and extending about the lower end of the core; (f) structural support means disposed between the containment structure base mat and bottom end of the reactor vessel wall and cooperating for supporting the reactor vessel at its bottom end wall on the containment structure base mat to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event; (g) a bed of insulating material disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall; freely expand radially from the central post as it heats up while providing continuous support thereof; (h) a deck supported upon the wall of the containment vessel above the top open end of the reactor vessel; and (i) extendible and retractable coupling means extending between the deck and the top open end of the reactor vessel and flexibly and sealably interconnecting the reactor vessel at its top end to the deck

  18. Intraoperative angiography in reconstructive vessel operations in the lower parts of the body

    International Nuclear Information System (INIS)

    Zehle, A.; Weinhold, C.H.; Hauger, W.

    1981-01-01

    The intraoperative angiography offers decisive advantages in reconstructive vessel operations, because this technique permits a direct and immediate examination of the obtained results and which thus can directly influence the technical and tactic management. Therefore this method allows in the most favourable case to improve prognosis. The technical realization and the procedure are facilitated by the combination of screening method and simple documentation, which is presented here. (orig./MG) [de

  19. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  20. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Nagashima, Keisuke [Japan Atomic Energy Research Inst., Tokyo (Japan); Suzuki, Masaru; Onozuka, Masaki

    1997-07-11

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  1. Probability of fracture and life extension estimate of the high-flux isotope reactor vessel

    International Nuclear Information System (INIS)

    Chang, S.J.

    1998-01-01

    The state of the vessel steel embrittlement as a result of neutron irradiation can be measured by its increase in ductile-brittle transition temperature (DBTT) for fracture, often denoted by RT NDT for carbon steel. This transition temperature can be calibrated by the drop-weight test and, sometimes, by the Charpy impact test. The life extension for the high-flux isotope reactor (HFIR) vessel is calculated by using the method of fracture mechanics that is incorporated with the effect of the DBTT change. The failure probability of the HFIR vessel is limited as the life of the vessel by the reactor core melt probability of 10 -4 . The operating safety of the reactor is ensured by periodic hydrostatic pressure test (hydrotest). The hydrotest is performed in order to determine a safe vessel static pressure. The fracture probability as a result of the hydrostatic pressure test is calculated and is used to determine the life of the vessel. Failure to perform hydrotest imposes the limit on the life of the vessel. The conventional method of fracture probability calculations such as that used by the NRC-sponsored PRAISE CODE and the FAVOR CODE developed in this Laboratory are based on the Monte Carlo simulation. Heavy computations are required. An alternative method of fracture probability calculation by direct probability integration is developed in this paper. The present approach offers simple and expedient ways to obtain numerical results without losing any generality. In this paper, numerical results on (1) the probability of vessel fracture, (2) the hydrotest time interval, and (3) the hydrotest pressure as a result of the DBTT increase are obtained

  2. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  3. High-performance fiber/epoxy composite pressure vessels

    Science.gov (United States)

    Chiao, T. T.; Hamstad, M. A.; Jessop, E. S.; Toland, R. H.

    1978-01-01

    Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

  4. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1975-01-01

    A description is given of a reactor pressure vessel which is provided with vertical support means in the form of circumferentially spaced columns upon which the vessel is mounted. The columns are adapted to undergo flexure in order to accommodate the thermally induced displacements experienced by the vessel during operational transients

  5. 50 CFR 648.4 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... carrying passengers for hire. (8) Atlantic bluefish vessels. (i) Commercial. Any vessel of the United... lands Atlantic bluefish in or from the EEZ in excess of the recreational possession limit specified at § 648.164 must have been issued and carry on board a valid commercial bluefish vessel permit. (ii) Party...

  6. Two Complementary Mechanisms Underpin Cell Wall Patterning during Xylem Vessel Development.

    Science.gov (United States)

    Schneider, Rene; Tang, Lu; Lampugnani, Edwin R; Barkwill, Sarah; Lathe, Rahul; Zhang, Yi; McFarlane, Heather E; Pesquet, Edouard; Niittyla, Totte; Mansfield, Shawn D; Zhou, Yihua; Persson, Staffan

    2017-10-01

    The evolution of the plant vasculature was essential for the emergence of terrestrial life. Xylem vessels are solute-transporting elements in the vasculature that possess secondary wall thickenings deposited in intricate patterns. Evenly dispersed microtubule (MT) bands support the formation of these wall thickenings, but how the MTs direct cell wall synthesis during this process remains largely unknown. Cellulose is the major secondary wall constituent and is synthesized by plasma membrane-localized cellulose synthases (CesAs) whose catalytic activity propels them through the membrane. We show that the protein CELLULOSE SYNTHASE INTERACTING1 (CSI1)/POM2 is necessary to align the secondary wall CesAs and MTs during the initial phase of xylem vessel development in Arabidopsis thaliana and rice ( Oryza sativa ). Surprisingly, these MT-driven patterns successively become imprinted and sufficient to sustain the continued progression of wall thickening in the absence of MTs and CSI1/POM2 function. Hence, two complementary principles underpin wall patterning during xylem vessel development. © 2017 American Society of Plant Biologists. All rights reserved.

  7. Requirements for thermal insulation on prestressed concrete reactor vessels

    International Nuclear Information System (INIS)

    Neylan, A.J.; Wistrom, J.D.

    1979-01-01

    During the past decade, extensive design, construction, and operating experience on concrete pressure vessels for gas-cooled reactor applications has accumulated. Excellent experience has been obtained to date on the structural components (concrete, prestressing systems, liners, penetrations, and closures) and the thermal insulation. Three fundamentally different types of insulation systems have been employed to ensure the satisfactory performance of this component, which is critical to the overall success of the prestressed concrete reactor vessel (PCRV). Although general design criteria have been published, the requirements for design, materials, and construction are not rigorously addressed in any national or international code. With the more onerous design conditions being imposed by advanced reactor systems, much greater attention has been directed to advance the state of the art of insulation systems for PCRVs. This paper addresses some of the more recent developments in this field being performed by General Atomic Company and others. (author)

  8. Histomorphological changes of vessel structure in head and neck vessels following preoperative or postoperative radiotherapy

    International Nuclear Information System (INIS)

    Schultze-Mosgau, S.; Wehrhan, F.; Wiltfang, J.; Grabenbauer, G.G.; Sauer, R.; Roedel, F.; Radespiel-Troeger, M.

    2002-01-01

    Patients and Methods: In 348 patients (October 1995-March 2002) receiving primarly or secondarily 356 microvascular hard- and soft tissue reconstruction, a total of 209 vessels were obtained from neck recipient vessels and transplant vessels during anastomosis. Three groups were analysed: group 1 (27 patients) treated with no radiotherapy or chemotherapy; group 2 (29 patients) treated with preoperative irradiation (40-50 Gy) and chemotherapy (800 mg/m 2 /day 5-FU and 20 mg/m 2 /day cisplatin) 1.5 months prior to surgery; group 3 (20 patients) treated with radiotherapy (60-70 Gy) (median interval 78.7 months; IQR: 31.3 months) prior to surgery. From each of the 209 vessel specimens, 3 sections were investigated histomorphometrically, qualitatively and quantitatively (ratio media area/total vessel area) by NIH-Image-digitized measurements. To evaluate these changes as a function of age, radiation dose and chemotherapy, a statistical analysis was performed using an analysis of covariance and χ 2 tests (p > 0.05, SPSS V10). Results: In group 3, qualitative changes (intima dehiscence, hyalinosis) were found in recipient arteries significantly more frequently than in groups 1 and 2. For group 3 recipient arteries, histomorphometry revealed a significant decrease in the ratio media area/total vessel area (median 0.51, IQR 0.10) in comparison with groups 1 (p = 0.02) (median 0.61, IQR 0.29) and 2 (p = 0.046) (median 0.58, IQR 0.19). No significant difference was found between the vessels of groups 1 and 2 (p = 0.48). There were no significant differences in transplant arteries and recipient or transplant veins between the groups. Age and chemotherapy did not appear to have a significant influence on vessel changes in this study (p > 0.05). Conclusions: Following irradiation with 60-70 Gy, significant qualitative and quantitative histological changes to the recipient arteries, but not to the recipient veins, could be observed. In contrast, irradiation at a dose of 40-50 Gy

  9. Defining an adequate sample of earlywood vessels for retrospective injury detection in diffuse-porous species.

    Directory of Open Access Journals (Sweden)

    Estelle Arbellay

    Full Text Available Vessels of broad-leaved trees have been analyzed to study how trees deal with various environmental factors. Cambial injury, in particular, has been reported to induce the formation of narrower conduits. Yet, little or no effort has been devoted to the elaboration of vessel sampling strategies for retrospective injury detection based on vessel lumen size reduction. To fill this methodological gap, four wounded individuals each of grey alder (Alnus incana (L. Moench and downy birch (Betula pubescens Ehrh. were harvested in an avalanche path. Earlywood vessel lumina were measured and compared for each tree between the injury ring built during the growing season following wounding and the control ring laid down the previous year. Measurements were performed along a 10 mm wide radial strip, located directly next to the injury. Specifically, this study aimed at (i investigating the intra-annual duration and local extension of vessel narrowing close to the wound margin and (ii identifying an adequate sample of earlywood vessels (number and intra-ring location of cells attesting to cambial injury. Based on the results of this study, we recommend analyzing at least 30 vessels in each ring. Within the 10 mm wide segment of the injury ring, wound-induced reduction in vessel lumen size did not fade with increasing radial and tangential distances, but we nevertheless advise favoring early earlywood vessels located closest to the injury. These findings, derived from two species widespread across subarctic, mountainous, and temperate regions, will assist retrospective injury detection in Alnus, Betula, and other diffuse-porous species as well as future related research on hydraulic implications after wounding.

  10. Device for positioning ultrasonic probes and/or television cameras on the outer surface of reactor pressure vessels

    International Nuclear Information System (INIS)

    Zipser, R.; Dose, G.F.

    1977-01-01

    The device makes possible periodical in-service inspections of welding seams and material of a reactor pressure vessel without local human presence. A 'support ring' encloses the pressure vessel in a horizontal plane with free space. It is vertically moved up and down in the space between pressure vessel and thermal shield by means of tackles. At a control desk placed in a protected area its movement is controlled and its vertical position is indicated. A 'rotating track' with its own drive is rotating remote-controlled on the 'support ring'. By a combination of the vertical with the rotating movement, an ultrasonic probe placed removably on the 'rotating hack', or a television camera will be brought to any position on the cylindrical circumference of the pressure vessel. Special devices extend the radius of action, in upward direction for inspecting the welding seams of the coolant nozzles, and in downward direction for the inspection of welds on the hemispherical bottom of the pressure vessel or on the outlet pipe nozzle placed there. The device remains installed during reactor operation, but is moved down to the lower horizontal surface of the thermal shield. Parts which are sensible to radiation like probes or television cameras and special devices will then be removed respectively mounted before beginning an inspection compaign. This position may be reached by the lower access in the biological shield and through an opening in the horizontal surface of the thermal shield. (HP) [de

  11. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    Energy Technology Data Exchange (ETDEWEB)

    Heel, A.M.J.M. van

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP).

  12. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    International Nuclear Information System (INIS)

    Heel, A.M.J.M. van.

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP)

  13. 19 CFR 4.97 - Salvage vessels.

    Science.gov (United States)

    2010-04-01

    ... United States and Great Britain ‘concerning reciprocal rights for United States and Canada in the... meaning of this statute. (e) A Mexican vessel may engage in a salvage operation on a Mexican vessel in any territorial waters of the United States in which Mexican vessels are permitted to conduct such operations by...

  14. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Hagiwara, Koji; Imura, Yasuya.

    1979-01-01

    Purpose: To provide constituted method for easily performing baking of vacuum vessel, using short-circuiting segments. Constitution: At the time of baking, one turn circuit is formed by the vacuum vessel and short-circuiting segments, and current transformer converting the one turn circuit into a secondary circuit by the primary coil and iron core is formed, and the vacuum vessel is Joule heated by an induction current from the primary coil. After completion of baking, the short-circuiting segments are removed. (Kamimura, M.)

  15. Structural analysis of the KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    In, Sang Ryul; Yoon, Byeong Joo [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-10-01

    Structure analysis of the vacuum vessel for the KSTAR tokamak which, is in the end phase of the conceptual design have been performed. Mechanical stresses and deformations of the vessel produced by constant forces due to atmospheric pressure, dead weight, fluid pressure, etc and various transient electromagnetic forces induced during tokamak operations were calculated as well as modal characteristics and buckling properties were investigated. Influences of the temperature gradient and the constraint condition of the support on the thermal stress and deformation of the vessel were analyzed. The thermal stress due to the temperature distribution on the vessel as supplying the N{sub 2} gas of 400 deg C through poloidal channels according to the recent baking concept were calculated. No severe problem in the robustness of the vessel was found when applying the constant pressures on the vessel. However the mechanical stress due to the EM force induced by halo currents flowing on the vessel and the plasma facing components (PFCs) far exceeded the allowable limit. Some reinforcing components should be added on the boundary of the PFC support and the vessel, and that of the vessel support and the vessel. A steep temperature gradient in the vicinity of the inlet and oulet of the heating gas produced a thermal stress much higher than allowable. It is necessary to make the temperature of the vessel as uniform as possible and to develop a new support concept which is flexible enough to accommodate a thermal expansion of a few cm while sufficiently strong to resist mechanical impacts. (author). 5 refs., 41 figs., 9 tabs.

  16. Pressure vessels and methods of sealing leaky tubes disposed in pressure vessels

    International Nuclear Information System (INIS)

    Larson, G.C.

    1980-01-01

    This invention relates to pressure vessels and to methods of sealing leaky tubes in them and is especially applicable to pressure vessels in the form of sheet-and-tube type heat exchangers constructed with a large number of relatively small diameter tubes grouped in a bundle. To seal off a leaky tube in such a heat exchanger an explosive activated plug in the form of a hollow metal body is used, inserted at each end of the tube to be sealed. Using the arrangement of pressure vessel and associated tube sheets and the explosive activated plug method of sealing a leaky tube as described in this invention it is claimed that distortion of the adjacent tubes and the tube sheets is reduced when the explosive activated plugs are detonated. (U.K.)

  17. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  18. Vitamin D Status in Small Vessel and Large Vessel Ischemic Stroke Patients: A Case–control Study

    Directory of Open Access Journals (Sweden)

    Navid Manouchehri

    2017-01-01

    Full Text Available Background: Vitamin D insufficiency is a globally widespread issue. Recent studies have reported a high prevalence of Vitamin D deficiency in Middle-East countries. Studies have shown negative effects of Vitamin D deficiency on endothelium and related diseases such as ischemic brain stroke. Here, we assessed Vitamin D status in patients with different types of ischemic brain stroke and control group. Materials and Methods: Seventy-five patients (49.3% small vessel, 50.7% large vessel and 75 controls, matched for age (68.01 ± 10.94 vs. 67.64 ± 10.24 and sex (42 male and 33 female were recruited. 25(OH D levels were measured by Chemiluminescence immunoassay. 25(OH D status was considered as severely, moderately, or mildly deficient and normal with 25(OH D levels of less than 5, 5-10, 10-16, and> 16 ng/ml, respectively. Results: Mean ± standard error concentration of 25(OH D in cases and controls were 17.7 ± 1.5 and 26.9 ± 1.6 (P = 0.0001, respectively. Mild, moderate, and severe Vitamin D deficiency were observed in 10.8%, 32.4%, 8.1% vs. 34.3%, 31.5%, 9.5% of small vessel and large vessel group, respectively. 21.7% of the controls were Vitamin D deficient. Vitamin D deficiency was significantly associated with higher risk for ischemic stroke, (P = 0.000, OR = 7.17, 95% confidence interval: 3.36–15.29. 25(OH D levels were significantly higher in control group comparing to small vessel (26.9 ± 1.6 vs. 20.59 ± 2.6 P < 0.05 and large vessel (26.9 ± 1.6 vs. 13.4 ± 1.3 P < 0.001 stroke patients. Small vessel group had significantly higher levels of Vitamin D than large vessel (P < 0.05. Conclusion: Vitamin D deficiency significantly increases the risk of ischemic stroke, favoring the types with the pathogenesis of large vessel strokes.

  19. Recent evaluation of 'wet' thermal annealing to resolve reactor pressure vessel embrittlement

    International Nuclear Information System (INIS)

    Server, W.L.; Biemiller, E.C.

    1993-01-01

    Prior to the decision to close the Yankee Rowe plant in 1992, a great deal of effort was expended in trying to resolve the degree of neutron embrittlement that the reactor pressure vessel had experienced after 30 years of operation. One mitigative measure that was examined in detail was the possibility of performing a relatively low temperature thermal anneal (at approximately 650 deg. F) to partially restore the original design level of mechanical properties of the reactor pressure vessel beltline region which were lost due to the neutron radiation exposure. This low temperature anneal was to involve heating of the primary coolant water using pump heat in a similar manner as that used to anneal the Belgian BR-3 reactor pressure vessel in the early 1980s. This 'wet' anneal was successful in recovering mechanical properties for the BR-3 vessel, but the extent of the recovery, as well as the rate of re-embrittlement after the anneal, were issues that were difficult to quantify since the exact reactor pressure vessel steels were not available for experimental verification. For the case of Yankee Rowe, material was available from past surveillance programs for at least one of the materials in the vessel, as well as materials obtained from various sources which could act as bounding surrogates. An irradiation /annealing/reirradiation program was developed to better quantify the degree of recovery and re-embrittlement for these materials, but this program was halted before significant test results were obtained. Prior to the initiation of the testing program, a review of past annealing data was performed and the data were scrutinized for direct relevance to the annealing response of the Yankee Rowe vessel. This paper discusses the results derived from this review. The results from the critical review of the past annealing data indicated that a 'wet' anneal of the Yankee Rowe vessel may have been successful in reducing the degree of embrittlement to the point that the

  20. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  1. Stress-rupture lifetimes of organic fiber-epoxy strands and pressure vessels

    International Nuclear Information System (INIS)

    Hahn, H.T.; Chiu, I.L.; Gates, T.L.

    1979-01-01

    Long-term behavior of filament-wound pressure vessels were tested, Kevlar 49 epoxy strands were studied in stress-rupture for more than a year. Because the strands are the smallest structural unit in filament winding, their behavior directly controls the performance of vessels. Five different stress levels were studied: 86, 80, 74, 68, and 50% of the mean ultimate tensile strength (UTS). At each stress level, approximately one-hundred strands were hung in a room maintained at 22 to 24 0 C and below 20% relative humidity. Failure times were automatically recorded by a data acquisition system. Lifetimes were analyzed statistically using a two-parameter Weibull distribution. The maximum-likelihood method was used to estimate the parameters. The shape parameter, which is a measure of scatter and failure-rate change, increased with decreasing stress level. Less scatter and increasing failure rates were observed at lower stresses. There was no sign of an endurance limit down to 68% UTS. At 50% UTS no failure had yet occurred after 9000 h. The strand data were compared with data on lifetimes of pressure vessels wound with the same fiber and epoxy. The strands had slightly longer characteristic lifetimes, except at 86% UTS, and slightly less scatter, except at 68% UTS. The results of this study indicate that strands can provide valuable information about the long-term performance of filament-wound pressure vessels

  2. Albatrosses following fishing vessels: how badly hooked are they on an easy meal?

    Directory of Open Access Journals (Sweden)

    José P Granadeiro

    Full Text Available Fisheries have major impacts on seabirds, both by changing food availability and by causing direct mortality of birds during trawling and longline setting. However, little is known about the nature and the spatial-temporal extent of the interactions between individual birds and vessels. By studying a system in which we had fine-scale data on bird movements and activity, and near real-time information on vessel distribution, we provide new insights on the association of a threatened albatross with fisheries. During early chick-rearing, black-browed albatrosses Thalassarche melanophris from two different colonies (separated by only 75 km showed significant differences in the degree of association with fisheries, despite being nearly equidistant to the Falklands fishing fleet. Most foraging trips from either colony did not bring tracked individuals close to vessels, and proportionally little time and foraging effort was spent near ships. Nevertheless, a few individuals repeatedly visited fishing vessels, which may indicate they specialise on fisheries-linked food sources and so are potentially more vulnerable to bycatch. The evidence suggests that this population has little reliance on fisheries discards at a critical stage of its nesting cycle, and hence measures to limit fisheries waste on the Patagonian shelf that also reduce vessel attractiveness and the risk of incidental mortality, would be of high overall conservation benefit.

  3. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  4. Protective interior wall and attaching means for a fusion reactor vacuum vessel

    International Nuclear Information System (INIS)

    Phelps, R.D.; Upham, G.A.; Anderson, P.M.

    1988-01-01

    A protective wall for the interior surface of a fusion reactor vessel wall is described comprising: an array of plates, each plate of the array including a main body section, a pair of edge sections bent at an angle with respect to the main body section, and a pair of flange-like end sections each having protruding sections with cut-aways therein, the protruding sections of the flange-like end sections extending in a direction substantially parallel to the main body section; and means operatively associated with the protruding sections of the flange-like end sections of the plates for mounting the array of plates to an associated vessel wall to be protected

  5. Tearing stability analysis of an axial surface flaw in thick-walled pressure vessels

    International Nuclear Information System (INIS)

    Zahoor, A.; Ghassemi, B.B.

    1991-01-01

    This paper presents two fracture mechanics models for evaluation of an axial surface flaw in pressure vessels. The surface flaw is located on the outside surface of the vessel. The first model assumes yielding of the remaining ligament directly ahead of the flaw. The second model assumes contained yielding ahead of the flaw and uses a linear elastic fracture mechanics solution. The former model is suitable for cases where the combination of material toughness, flaw size, and load is such that initiation of flaw growth follows ligament yielding. The latter model is suitable for low-toughness materials where initiation of crack growth and potential tearing instability may occur prior to the yielding of the ligament. Both models are suitable for thick-walled vessels. The paper discusses the applicability regime for both models. The models are then applied to a test vessel and the predicted failure pressure is compared against the pressure attained in the test. Results show that both models can be applied successfully. In particular, the contained yielding model when used with the plane-stress assumption can give reasonable predictions even for cases that involve yielding of the ligament. (orig.)

  6. Tearing stability analysis of an axial surface flaw in thick-walled pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Zahoor, A.; Ghassemi, B.B. (NOVETECH Corp., Rockville, MD (USA))

    1991-04-01

    This paper presents two fracture mechanics models for evaluation of an axial surface flaw in pressure vessels. The surface flaw is located on the outside surface of the vessel. The first model assumes yielding of the remaining ligament directly ahead of the flaw. The second model assumes contained yielding ahead of the flaw and uses a linear elastic fracture mechanics solution. The former model is suitable for cases where the combination of material toughness, flaw size, and load is such that initiation of flaw growth follows ligament yielding. The latter model is suitable for low-toughness materials where initiation of crack growth and potential tearing instability may occur prior to the yielding of the ligament. Both models are suitable for thick-walled vessels. The paper discusses the applicability regime for both models. The models are then applied to a test vessel and the predicted failure pressure is compared against the pressure attained in the test. Results show that both models can be applied successfully. In particular, the contained yielding model when used with the plane-stress assumption can give reasonable predictions even for cases that involve yielding of the ligament. (orig.).

  7. Design of the Intersector Welding Robot for vacuum vessel assembly and maintenance

    International Nuclear Information System (INIS)

    Jones, L.; Dagenais, J.-F.; Daenner, W.; Maisonnier, D.

    2000-01-01

    Next Step Fusion Devices require on-site (field weld) joining of sectors of the thick-walled vacuum vessel for structural and vacuum integrity. EFDA (European Fusion Development Agreement) is supporting an R and D programme to investigate processes for assembly of the vacuum vessel and to carry out cutting, re-welding and inspection for remote sector replacement, forming part of the overall VV/blanket research effort. In order to direct the process end-effectors along the field joint zone, a track-mounted Intersector Welding Robot (IWR) on a mock-up of a region of the vacuum vessel has been designed and is described in this paper. A rail-mounted hexapod type robot offers six axes of motion over a limited work envelope with high payload to robot weight ratio. A solution to the production of reduced pressure local vacuum is the installation of short, lightweight segments bolted to each other and the vessel wall. The various process heads can be mounted using end-effectors of special design. To minimise the supply and interface problems for the IWR prototype, its motion control and electronic systems will be embedded locally. A laser scan with camera forms the on-line seam tracking capability to compensate for rail and seam deviations

  8. Assessment of reactor vessel integrity (ARVI)

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R. E-mail: sehgal@ne.kth.se; Theerthan, A.; Giri, A.; Karbojian, A.; Willschuetz, H.G.; Kymaelaeinen, O.; Vandroux, S.; Bonnet, J.M.; Seiler, J.M.; Ikkonen, K.; Sairanen, R.; Bhandari, S.; Buerger, M.; Buck, M.; Widmann, W.; Dienstbier, J.; Techy, Z.; Kostka, P.; Taubner, R.; Theofanous, T.; Dinh, T.N

    2003-04-01

    The cost-shared project ARVI (assessment of reactor vessel integrity) involves a total of nine organisations from Europe and USA. The objective of the ARVI Project is to resolve the safety issues that remain unresolved for the melt vessel interaction phase of the in-vessel progression of a severe accident. The work consists of experiments and analysis development. Four tests were performed in the EC-FOREVER Programme, in which failure was achieved in-vessels employing the French pressure vessel steel. The tests were analysed with the commercial code ANSYS-Multiphysics, and the codes SYSTUS+ and PASULA, and quite good agreement was achieved for the failure location. Natural convection experiments in stratified pools have been performed in the SIMECO and the COPO facilities, which showed that much greater heat is transferred downwards for immiscible layers or before layers mix. A model for gap cooling and a set of simplified models for the system codes have been developed. MVITA code calculations have been performed for the Czech and Hungarian VVERs, towards evaluation of the in-vessel melt retention accident management scheme. Tests have been performed at the ULPU facility with organised flow for vessel external cooling. Considerable enhancement of the critical heat flux (CHF) was obtained. The ARVI Project has reached the halfway stage. This paper presents the results obtained thus far from the project.

  9. Neutron Assay System for Confinement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le)100-g 239 Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.

  10. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  11. Nuclear reactor pressure vessel-specific flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.

    1992-01-01

    Vessel integrity predictions performed through fracture mechanics analysis of a pressurized thermal shock event have been shown to be significantly sensitive to the overall flaw distribution input. It has also been shown that modem vessel in-service inspection (ISI) results can be used for development of vessel flaw distribution(s) that are more representative of US vessels. This paper describes the development and application of a methodology to analyze ISI data for the purpose of flaw distribution determination. The resultant methodology considers detection reliability, flaw sizing accuracy, and flaw detection threshold in its application. Application of the methodology was then demonstrated using four recently acquired US PWR vessel inspection data sets. Throughout the program, new insight was obtained into several key inspection performance and vessel integrity prediction practice issues that will impact future vessel integrity evaluation. For example, the potential application of a vessel-specific flaw distribution now provides at least one method by which a vessel-specific reference flaw size applicable to pressure-temperature limit curves determination can be estimated. This paper will discuss the development and application of the methodology and the impact to future vessel integrity analyses

  12. Integral experiments on in-vessel coolability and vessel creep: results and analysis of the FOREVER-C1 test

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Nourgaliev, R.R.; Dinh, T.N.; Karbojian, A. [Division of Nuclear Power Safety, Royal Institute of Technology, Drottning Kristinas Vaeg., Stockholm (Sweden)

    1999-07-01

    This paper describes the FOREVER (Failure Of REactor VEssel Retention) experimental program, which is currently underway at the Division of Nuclear Power Safety, Royal Institute of Technology (RIT/NPS). The objectives of the FOREVER experiments are to obtain data and develop validated models (i) on the melt coolability process inside the vessel, in the presence of water (in particular, on the efficacy of the postulated gap cooling to preclude vessel failure); and (ii) on the lower head failure due to the creep process in the absence of water inside and/or outside the lower head. The paper presents the experimental results and analysis of the first FOREVER-C1 test. During this experiment, the 1/10th scale pressure vessel, heated to about 900degC and pressurized to 26 bars, was subjected to creep deformation in a non-stop 24-hours test. The vessel wall displacement data clearly shows different stages of the vessel deformation due to thermal expansion, elastic, plastic and creep processes. The maximum displacement was observed at the lowermost region of the vessel lower plenum. Information on the FOREVER-C1 measured thermal characteristics and analysis of the observed thermal and structural behavior is presented. The coupled nature of thermal and mechanical processes, as well as the effect of other system conditions (such as depressurization) on the melt pool and vessel temperature responses are analyzed. (author)

  13. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  14. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7A under sustained loading

    International Nuclear Information System (INIS)

    Bryan, R.H.; Cate, T.M.; Holz, P.P.; King, T.A.; Merkle, J.G.; Robinson, G.C.; Smith, G.C.; Smith, J.E.; Whitman, G.D.

    1978-01-01

    HSST intermediate test vessel V-7 was repaired after being tested hydrostatically to leakage and was retested pneumatically as vessel V-7A. Except for the method of applying the load, the conditions in both tests were nearly identical. In each case, a sharp outside surface flaw 547 mm long (18 in.) by about 135 mm deep (5.3 in.) was prepared in the 152-mm-thick (6-in.) test cylinder of A533, grade B, class 1 steel. The inside surface of vessel V-7A was sealed in the region of the flaw by a thin metal patch so that pressure could be sustained after rupture. Vessel V-7A failed by rupture of the flaw ligament without burst, as expected. Rupture occurred at 144.3 MPa (20.92 ksi), after which pressure was sustained for 30 min without any indication of instability. The rupture pressure of vessel V-7A was about 2 percent less than that of vessel V-7

  15. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    metals (e.g., cadmium, chromium, lead, copper , zinc, silver, nickel, and mercury), solids, and nutrients (USEPA, 2008b; USEPA 2010). Wastewater from... flotation ), and disinfection (using ultraviolet light) as compared to traditional Type II MSDs that use either simple maceration and chlorination, or...Coliform Naval Vessels Oceanographic Vessels Small Cruise Ships 25a Vendor 2 Hamann AG Biological Treatment with Dissolved Air Flotation and

  16. Accelerated irradiation test of Gundremmingen reactor vessel trepan material

    Energy Technology Data Exchange (ETDEWEB)

    Hawthorne, J.R. [Materials Engineering Associates, Inc., Lanham, MD (United States)

    1992-08-01

    Initial mechanical properties tests of beltline trepanned from the decommissioned KRB-A pressure vessel and archive material irradiated in the UBR test reactor revealed a major anomaly in relative radiation embrittlement sensitivity. Poor correspondence of material behavior in test vs. power reactor environments was observed for the weak test orientation (ASTL C-L) whereas correspondence was good for the strong orientation (ASTM C-L). To resolve the anomaly directly, Charpy-V specimens from a low (essentially-nil) fluence region of the vessel were irradiated together with archive material at 279{degrees}C in the UBR test reactor. Properties tests before UBR irradiation revealed a significant difference in 41-J transition temperature and upper shelf energy level between the materials. However, the materials exhibited essentially the same radiation embrittlement sensitivity (both orientations), proving that the anomaly is not due to a basic difference in material irradiation resistances. Possible causes of the original anomaly and the significance to NRC Regulatory Guide 1.99 are discussed.

  17. Accelerated irradiation test of gundremmingen reactor vessel trepan material

    International Nuclear Information System (INIS)

    Hawthorne, J.R.

    1992-08-01

    Initial mechanical properties tests of beltline trepanned from the decommissioned KRB-A pressure vessel and archive material irradiated in the UBR test reactor revealed a major anomaly in relative radiation embrittlement sensitivity. Poor correspondence of material behavior in test vs. power reactor environments was observed for the weak test orientation (ASTL C-L) whereas correspondence was good for the strong orientation (ASTM C-L). To resolve the anomaly directly, Charpy-V specimens from a low (essentially-nil) fluence region of the vessel were irradiated together with archive material at 279 degrees C in the UBR test reactor. Properties tests before UBR irradiation revealed a significant difference in 41-J transition temperature and upper shelf energy level between the materials. However, the materials exhibited essentially the same radiation embrittlement sensitivity (both orientations), proving that the anomaly is not due to a basic difference in material irradiation resistances. Possible causes of the original anomaly and the significance to NRC Regulatory Guide 1.99 are discussed

  18. Recent development for inservice inspection of reactor pressure vessels

    International Nuclear Information System (INIS)

    Fischer, K.; Engl, G.; Rathgeb, W.; Heumueller, R.

    1991-01-01

    The German Nuclear Code (KTA-rules) requires a full scope inservice inspection (ISI) of reactor pressure vessels within a period of four years. This has a remarkable influence on plant operation and economy. Therefore, the development of advanced inspection equipment and techniques is directed not only to the enhancement of defect detectability and flaw sizing capabilities but also to reducing inspection times. A new manipulator system for PWR vessels together with fast data processing reduces the time for ISI of modern RPVs to 7 days. A new multichannel UT-system based on ALOK principle offers increased ultrasonic information with comfortable and rapid evaluation and presentation of results together with enhanced sizing capabilities. For specific inspection problems characterized by geometrical complexity the application of phased array probes in connection with UT-tomography provides improved ultrasonic information together with a streamlined manipulator principle and simplification of set up and tear down at the component which results in considerable reduction of radiation exposure. (orig.)

  19. Vascular patterns in the heads of crocodilians: blood vessels and sites of thermal exchange.

    Science.gov (United States)

    Porter, William Ruger; Sedlmayr, Jayc C; Witmer, Lawrence M

    2016-12-01

    Extant crocodilians are a highly apomorphic archosaur clade that is ectothermic, yet often achieve large body sizes that can be subject to higher heat loads. Therefore, the anatomical and physiological roles that blood vessels play in crocodilian thermoregulation need further investigation to better understand how crocodilians establish and maintain cephalic temperatures and regulate neurosensory tissue temperatures during basking and normal activities. The cephalic vascular anatomy of extant crocodilians, particularly American alligator (Alligator mississippiensis) was investigated using a differential-contrast, dual-vascular injection technique and high resolution X-ray micro-computed tomography (μCT). Blood vessels were digitally isolated to create representations of vascular pathways. The specimens were then dissected to confirm CT results. Sites of thermal exchange, consisting of the oral, nasal, and orbital regions, were given special attention due to their role in evaporative cooling and cephalic thermoregulation in other diapsids. Blood vessels to and from sites of thermal exchange were studied to detect conserved vascular patterns and to assess their ability to deliver cooled blood to neurosensory tissues. Within the orbital region, both the arteries and veins demonstrated consistent branching patterns, with the supraorbital, infraorbital, and ophthalmotemporal vessels supplying and draining the orbit. The venous drainage of the orbital region showed connections to the dural sinuses via the orbital veins and cavernous sinus. The palatal region demonstrated a vast plexus that comprised both arteries and veins. The most direct route of venous drainage of the palatal plexus was through the palatomaxillary veins, essentially bypassing neurosensory tissues. Anastomotic connections with the nasal region, however, may provide an alternative route for palatal venous blood to reach neurosensory tissues. The nasal region in crocodilians is probably the most

  20. Reactor vessel decommissioning project. Final report

    International Nuclear Information System (INIS)

    Schoonen, D.H.

    1984-09-01

    This report describes a reactor vessel decommissioning project; it documents and explains the project objectives, scope, performance results, and sodium removal process. The project was successfully completed in FY-1983, within budget and without significant problems or adverse impact on the environment. Waste generated by the operation included the reactor vessel, drained sodium, and liquid, solid, and gaseous wastes which were significantly less than project estimates. Personnel radiation exposures were minimized, such that the project total was one-half the predicted exposure level. Except for the sodium removed, the material remaining in the reactor vessel is essentially the same as when the vessel arrived for processing

  1. Electrical discharge machining for vessel sample removal

    International Nuclear Information System (INIS)

    Litka, T.J.

    1993-01-01

    Due to aging-related problems or essential metallurgy information (plant-life extension or decommissioning) of nuclear plants, sample removal from vessels may be required as part of an examination. Vessel or cladding samples with cracks may be removed to determine the cause of cracking. Vessel weld samples may be removed to determine the weld metallurgy. In all cases, an engineering analysis must be done prior to sample removal to determine the vessel's integrity upon sample removal. Electrical discharge machining (EDM) is being used for in-vessel nuclear power plant vessel sampling. Machining operations in reactor coolant system (RCS) components must be accomplished while collecting machining chips that could cause damage if they become part of the flow stream. The debris from EDM is a fine talclike particulate (no chips), which can be collected by flushing and filtration

  2. Nuclear power plant pressure vessels. Inservice inspections

    International Nuclear Information System (INIS)

    1995-01-01

    The requirements for the planning and reporting of inservice inspections of nuclear power plant pressure vessels are presented. The guide specifically applies to inservice inspections of Safety class 1 and 2 nuclear power plant pressure vessels, piping, pumps and valves plus their supports and reactor pressure vessel internals by non- destructive examination methods (NDE). Inservice inspections according to the Pressure Vessel Degree (549/73) are discussed separately in the guide YVL 3.0. (4 refs.)

  3. Offshore wind transport and installation vessel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The initial objective of the project was to complete a feasibility study to determine the viability of an innovative transportation vessel to be deployed in the installation of offshore wind farms. This included the feasibility of providing a stable-working platform that can be used in harsh offshore environments. A study of current installation contractors and their installation equipment was used to provide a preliminary specification for the installation vessel. A typical barge was selected and a number of hydrodynamic analyses were carried out in order to establish it's on course and operational stability. The analysis proved the stability of the vessel during operation was critical and that in order to utilise the crane's full potential a stabilisation system must be employed. The main aim of the work to date was to establish whether it was feasible to use a stabilisation system on the installation vessel. The spud leg FEED study established that it was feasible to use spud legs to stabilise the vessel. In order to achieve the degree of stability required it is necessary to lift the vessel completely out of the water. This was not the original aim of the study but due to the external loads on the hull it was the only viable option. Lifting the vessel out of the water results in the legs and leg casings becoming very large. This has a number of consequences for the final design. Due to large loads on the legs spud cans must be used to avoid bottom penetration, the spud cans increase the draft of the vessel by 2m. The large loads require larger winches and more reeving to be used, this results in larger pumps and motors, all of which have to be housed. The stabilisation system has been proved to be feasible for a large installation vessel, the cost and physical size are however more excessive than first anticipated. (Author)

  4. 46 CFR 15.405 - Familiarity with vessel characteristics.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Familiarity with vessel characteristics. 15.405 Section... MANNING REQUIREMENTS Manning Requirements; All Vessels § 15.405 Familiarity with vessel characteristics. Each credentialed individual must become familiar with the relevant characteristics of the vessel on...

  5. No evidence for an open vessel effect in centrifuge-based vulnerability curves of a long-vesselled liana (Vitis vinifera).

    Science.gov (United States)

    Jacobsen, Anna L; Pratt, R Brandon

    2012-06-01

    Vulnerability to cavitation curves are used to estimate xylem cavitation resistance and can be constructed using multiple techniques. It was recently suggested that a technique that relies on centrifugal force to generate negative xylem pressures may be susceptible to an open vessel artifact in long-vesselled species. Here, we used custom centrifuge rotors to measure different sample lengths of 1-yr-old stems of grapevine to examine the influence of open vessels on vulnerability curves, thus testing the hypothesized open vessel artifact. These curves were compared with a dehydration-based vulnerability curve. Although samples differed significantly in the number of open vessels, there was no difference in the vulnerability to cavitation measured on 0.14- and 0.271-m-long samples of Vitis vinifera. Dehydration and centrifuge-based curves showed a similar pattern of declining xylem-specific hydraulic conductivity (K(s)) with declining water potential. The percentage loss in hydraulic conductivity (PLC) differed between dehydration and centrifuge curves and it was determined that grapevine is susceptible to errors in estimating maximum K(s) during dehydration because of the development of vessel blockages. Our results from a long-vesselled liana do not support the open vessel artifact hypothesis. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  6. Test of 6-inch-thick pressure vessels. Series 2. Intermediate test vessels V-3, V-4, and V-6

    International Nuclear Information System (INIS)

    Bryan, R.H.; Merkle, J.G.; Raftenberg, M.N.; Robinson, G.C.; Smith, J.E.

    1975-11-01

    The second series of intermediate vessel tests were crack initiation fracture tests of 6-in.-thick 39-in.-OD steel vessels with sharp surface flaws approximately 2 1 / 2 in. deep by 8 in. long in the longitudinal weld seams of the test cylinders. Fracture was initiated by means of hydraulic pressurization. One vessel was tested at each of three temperatures: 75, 130, and 190 0 F. Pretest analyses were made to predict the failure pressures and strains. Fracture toughness data obtained by equivalent-energy analysis of precracked Charpy-V tests and compact-tension specimen tests were used in the fracture analyses. The vessels behaved generally as had been expected. Posttest fracture analyses were also performed for each vessel. Detailed discussions of the fracture analysis methods developed in support of the vessel tests described are included. 34 references

  7. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  8. TPX vacuum vessel transient thermal and stress conditions

    International Nuclear Information System (INIS)

    Feldshteyn, Y.; Dinkevich, S.; Feng, T.; Majumder, D.

    1995-01-01

    The TPX vacuum vessel provides the vacuum boundary for the plasma and the mechanical support for the internal components. Another function of the vacuum vessel is to contain neutron shielding water in the double wall space during normal operation. This double wall space serves as a heat reservoir for the entire vacuum vessel during bakeout. The vacuum vessel and the internal components are subjected to thermal stresses induced by a nonuniform temperature distribution within the structure during bakeout. A successful Conceptual Design Review in March 1993 has established superheated steam as the heating source of the vacuum vessel. A transient bakeout mode of the vacuum vessel and in-vessel components has been analyzed to evaluate transient period duration, proper temperature level, actual thermal stresses and performance of the steam equipment. Thermally, the vacuum vessel structure may be considered as an adiabatic system because it is perfectly insulated by the strong surrounding vacuum and multiple layers of superinsulation. Important aspects of the analysis are described herein

  9. In service inspection of SUPERPHENIX 1 vessels: MIR

    International Nuclear Information System (INIS)

    Asty, M.; Viard, J.; Lerat, B.; Saglio, R.

    1985-01-01

    Although no in-service inspection constraints were imposed on the Phenix vessels, the Safety Authorities asked that the design of SUPERPHENIX 1 makes it possible to monitor throughout the lifetime of the reactor, surface and internal defects on the main vessel. A pool design and the presence of heat baffles inside the main vessel make access from the inside of the vessel impossible. Thus, an inspection can only be performed from the outside of the main vessel: the distance between the walls of the main and safety vessels is such that an inspection device can be introduced into the corresponding space. As the design of the reactor precludes radiographic inspection, the method which was selected for monitoring internal defects in the main vessel is ultrasonics. However, the anisotropic structure of austenitic stainless steel welds limits the performance of this technique. The authors present the in-service inspection device, MIR, which has been specially developed for the visual and ultrasonic examination of SUPERPHENIX 1 vessels

  10. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  11. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  12. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  13. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  14. Final report for the 1st ex-vessel neutron dosimetry installation and evaluations for Kori unit 4 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 4 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 16 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 4 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 16.

  15. Confinement Vessel Assay System: Calibration and Certification Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Gomez, Cipriano [Retired CMR-OPS: OPERATIONS; Mayo, Douglas R. [Los Alamos National Laboratory; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-17

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le} 100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  16. Confinement Vessel Assay System: Calibration and Certification Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Gomez, Cipriano; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le) 100-g 239 Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  17. Method for temporary shielding of reactor vessel internals

    International Nuclear Information System (INIS)

    Grimm, N.P.; Sejvar, J.

    1991-01-01

    This patent describes a method for shielding stored internals for reactor vessel annealing. It comprises removing nuclear fuel from the reactor vessel containment building; removing and storing upper and lower core internals under water in a refueling canal storage area; assembling a support structure in the refueling canal between the reactor vessel and the stored internals; introducing vertical shielding tanks individually through a hatch in the containment building and positioning each into the support structure; introducing horizontal shielding tanks individually through a hatch in the containment building and positioning each above the stored internals and vertical tanks; draining water from the refueling canal to the level of a flange of the reactor vessel; placing an annealing apparatus in the reactor vessel; pumping the remaining water from the reactor vessel; and annealing the reactor vessel

  18. Sediment resuspension events induced by the wake wash of deep-draft vessels

    Science.gov (United States)

    Garel, Erwan; López Fernández, Laura; Collins, Mike

    2008-08-01

    Hydrodynamics and sediment resuspension events, induced at the shoreline by a deep-draft vessel passing nearby, are described. Measurements (pressure, currents and turbidity) were obtained at 4 Hz, on a lower beach ~50 m from a channel where large car ferries operate in Wootton Creek, Isle of Wight. The study focuses on a representative 8-min 32-s-long record, during which two large vessels passed the channel section. At the shore, the passage of each vessel induced a long-period water-level drawdown, followed by a water-level oscillation (seiche) of similar period, and the short-period waves of the wake. Both drawdowns were the main constituents of the prevailing wave pattern. The second drawdown was the largest in amplitude, in response to a higher speed of the ferry, and the influence of the seiche which had been activated during the preceding event. Two successive peaks of turbidity were observed shortly after this drawdown. Analyses of current velocity and direction indicate that the sediments resuspended originated from the shallower upper beach. Anthropogenically induced erosion of the foreshore is predicted at Wootton Creek.

  19. Life extension of the BR2 aluminium vessel

    International Nuclear Information System (INIS)

    Koonen, E.; Fabry, A.; Chaouadi, R.; Verwerft, M.; Raedt, C. de; Winckel, S. van; Wacquier, W.; Dadoumont, J.; Verwimp, A.

    2000-01-01

    The BR2 reactor has recently undergone a major refurbishment comprising the replacement of all vessel internals. The vessel itself however was not replaced. An important requalification programme has been executed to prove that the vessel would remain fit during the contemplated life extension period of BR2. Representative material samples could be obtained from the shroud surrounding the vessel. A comprehensive in-service inspection was carried out and a vessel surveillance programme has been established. (author)

  20. Probabilistic atlas based labeling of the cerebral vessel tree

    Science.gov (United States)

    Van de Giessen, Martijn; Janssen, Jasper P.; Brouwer, Patrick A.; Reiber, Johan H. C.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke

    2015-03-01

    Preoperative imaging of the cerebral vessel tree is essential for planning therapy on intracranial stenoses and aneurysms. Usually, a magnetic resonance angiography (MRA) or computed tomography angiography (CTA) is acquired from which the cerebral vessel tree is segmented. Accurate analysis is helped by the labeling of the cerebral vessels, but labeling is non-trivial due to anatomical topological variability and missing branches due to acquisition issues. In recent literature, labeling the cerebral vasculature around the Circle of Willis has mainly been approached as a graph-based problem. The most successful method, however, requires the definition of all possible permutations of missing vessels, which limits application to subsets of the tree and ignores spatial information about the vessel locations. This research aims to perform labeling using probabilistic atlases that model spatial vessel and label likelihoods. A cerebral vessel tree is aligned to a probabilistic atlas and subsequently each vessel is labeled by computing the maximum label likelihood per segment from label-specific atlases. The proposed method was validated on 25 segmented cerebral vessel trees. Labeling accuracies were close to 100% for large vessels, but dropped to 50-60% for small vessels that were only present in less than 50% of the set. With this work we showed that using solely spatial information of the vessel labels, vessel segments from stable vessels (>50% presence) were reliably classified. This spatial information will form the basis for a future labeling strategy with a very loose topological model.

  1. Reactor pressure vessel status report

    International Nuclear Information System (INIS)

    Strosnider, J.; Wichman, K.; Elliot, B.

    1994-12-01

    This report gives a brief description of the reactor pressure vessel (RPV), followed by a discussion of the radiation embrittlement of RPV beltline materials and the two indicators for measuring embrittlement, the end-of-license (EOL) reference temperature and the EOL upper-shelf energy. It also summarizes the GL 92-01 effort and presents, for all 37 boiling water reactor plants and 74 pressurized water reactor plants in the United States, the current status of compliance with regulatory requirements related to ensuring RPV integrity. The staff has evaluated the material data needed to predict neutron embrittlement of the reactor vessel beltline materials. These data will be stored in a computer database entitled the reactor vessel integrity database (RVID). This database will be updated annually to reflect the changes made by the licensees in future submittals and will be used by the NRC staff to assess the issues related to vessel structural integrity

  2. Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency: Twelve-Month Results of the DEFINITIVE AR Study.

    Science.gov (United States)

    Zeller, Thomas; Langhoff, Ralf; Rocha-Singh, Krishna J; Jaff, Michael R; Blessing, Erwin; Amann-Vesti, Beatrice; Krzanowski, Marek; Peeters, Patrick; Scheinert, Dierk; Torsello, Giovanni; Sixt, Sebastian; Tepe, Gunnar

    2017-09-01

    Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency-A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB ( P =0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P =0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB ( P =0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB ( P =0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB ( P =0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB ( P =0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB ( P =0.86). DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. http://www.clinicaltrials.gov. Unique Identifier: NCT01366482. Copyright © 2017 The

  3. Experimental tests on buckling of ellipsoidal vessel heads subjected to internal pressure

    International Nuclear Information System (INIS)

    Roche, R.L.; Alix, M.

    1980-05-01

    Tests were performed on 17 ellipsoidal vessel heads of three different materials and different geometries. The results include the following: 1) Accurate definition of the geometry and particularly a direct measurement of the thickness along the meridian. 2) The properties of the material of each head, obtained from test specimens cut from the head itself after the test. 3) The recording of deflection/pressure curves with indication of the pressure at which buckling occurred. These results can be used for validation and qualification of methods for calculating the buckling load when plasticity occurs before buckling. It was possible to develop an empirical equation representing the experimental results obtained with satisfactory accuracy. This equation may be useful in pressure vessel design

  4. Prothrombin Time Prolongation was the Most Important Indicator of Severe Bleeding in Children with Severe Dengue Viral Infection.

    Science.gov (United States)

    Laoprasopwattana, Kamolwish; Binsaai, Jehrabeeyah; Pruekprasert, Pornpimol; Geater, Alan

    2017-08-01

    To determine the indicators of severe bleeding in children with severe dengue viral infection (DVI), the medical records of patients aged <15 years admitted to Songklanagarind Hospital in southern Thailand during 1989-2011 were reviewed. Severe-bleeding DVI was defined as needing blood products transfusion owing to DVI-caused bleeding. Of the 238 children with severe DVI according to the World Health Organization 2009 criteria, 44 (18.5%) had severe bleeding, of whom 28 (63.6%) died. The international normalized ratio (INR) had high correlations with both transaminase enzymes (Spearman correlation, rs = 0.67-0.69, p <0.01). Multivariate analysis found that patients who had dengue haemorrhagic fever (DHF) grade IV, platelets <20 000/mm3 and INR ≥ 1.5 had increased risk of severe bleeding with odds ratios (95% confidence intervals) of 3.4 (1.4, 8.6), 2.6 (1.1, 6.2) and 10.6 (4.0, 28.4), respectively. Blood products should be at hand in severe DHF children with high risk of severe bleeding. © The Author [2017]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Radioactive liquid containing vessel

    International Nuclear Information System (INIS)

    Sakurada, Tetsuo; Kawamura, Hironobu.

    1993-01-01

    Cooling jackets are coiled around the outer circumference of a container vessel, and the outer circumference thereof is covered with a surrounding plate. A liquid of good conductivity (for example, water) is filled between the cooling jackets and the surrounding plate. A radioactive liquid is supplied to the container vessel passing through a supply pipe and discharged passing through a discharge pipe. Cooling water at high pressure is passed through the cooling water jackets in order to remove the heat generated from the radioactive liquid. Since cooling water at high pressure is thus passed through the coiled pipes, the wall thickness of the container vessel and the cooling water jackets can be reduced, thereby enabling to reduce the cost. Further, even if the radioactive liquid is leaked, there is no worry of contaminating cooling water, to prevent contamination. (I.N.)

  6. The pressure vessel for the NSF tandem

    International Nuclear Information System (INIS)

    Jones, C.W.

    1979-04-01

    The pressure vessel is a major component of the 30 MV tandem Van de Graaff electrostatic accelerator to be used in nuclear structure research at Daresbury Laboratory. The accelerator will be capable of accelerating the full range of ions in the form of a beam. Acceleration takes place in a vertical evacuated tube (beam tube) by means of a high potential on a terminal at the central position, the terminal and beam tube assembly being supported by an insulated stack structure within the pressure vessel. Under operating conditions the vessel is filled with sulphur hexafluoride gas (SF 6 ) at high pressure which acts as an insulating medium between the centre terminal and the vessel wall. The vessel is situated inside a concrete tower which besides supporting the injector room above the vessel also acts as radiation shielding around the accelerator. The report covers: functional requirements; fundamental considerations with regard to the design and procurement; detail design; materials; manufacture; acceptance test; surface treatment; final leak test. (U.K.)

  7. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  8. Limiting Factors for External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Cheung, F.B.

    2005-01-01

    The method of external reactor vessel cooling (ERVC) that involves flooding of the reactor cavity during a severe accident has been considered a viable means for in-vessel retention (IVR). For high-power reactors, however, there are some limiting factors that might adversely affect the feasibility of using ERVC as a means for IVR. In this paper, the key limiting factors for ERVC have been identified and critically discussed. These factors include the choking limit for steam venting (CLSV) through the bottleneck of the vessel/insulation structure, the critical heat flux (CHF) for downward-facing boiling on the vessel outer surface, and the two-phase flow instabilities in the natural circulation loop within the flooded cavity. To enhance ERVC, it is necessary to eliminate or relax these limiting factors. Accordingly, methods to enhance ERVC and thus improve margins for IVR have been proposed and demonstrated, using the APR1400 as an example. The strategy is based on using two distinctly different methods to enhance ERVC. One involves the use of an enhanced vessel/insulation design to facilitate steam venting through the bottleneck of the annular channel. The other involves the use of an appropriate vessel coating to promote downward-facing boiling. It is found that the use of an enhanced vessel/insulation design with bottleneck enlargement could greatly facilitate the process of steam venting through the bottleneck region as well as streamline the resulting two-phase motions in the annular channel. By selecting a suitable enhanced vessel/insulation design, not only the CLSV but also the CHF limits could be significantly increased. In addition, the problem associated with two-phase flow instabilities and flow-induced mechanical vibration could be minimized. It is also found that the use of vessel coatings made of microporous metallic layers could greatly facilitate downward-facing boiling on the vessel outer surface. With vessel coatings, the local CHF limits at

  9. Proactive life extension of pressure vessels

    Science.gov (United States)

    Mager, Lloyd

    1998-03-01

    For a company to maintain its competitive edge in today's global market every opportunity to gain an advantage must be exploited. Many companies are strategically focusing on improved utilization of existing equipment as well as regulatory compliance. Abbott Laboratories is no exception. Pharmaceutical companies such as Abbott Laboratories realize that reliability and availability of their production equipment is critical to be successful and competitive. Abbott Laboratories, like many of our competitors, is working to improve safety, minimize downtime and maximize the productivity and efficiency of key production equipment such as the pressure vessels utilized in our processes. The correct strategy in obtaining these objectives is to perform meaningful inspection with prioritization based on hazard analysis and risk. The inspection data gathered in Abbott Laboratories pressure vessel program allows informed decisions leading to improved process control. The results of the program are reduced risks to the corporation and employees when operating pressure retaining equipment. Accurate and meaningful inspection methods become the cornerstone of a program allowing proper preventative maintenance actions to occur. Successful preventative/predictive maintenance programs must utilize meaningful nondestructive evaluation techniques and inspection methods. Nondestructive examination methods require accurate useful tools that allow rapid inspection for the entire pressure vessel. Results from the examination must allow the owner to prove compliance of all applicable regulatory laws and codes. At Abbott Laboratories the use of advanced NDE techniques, primarily B-scan ultrasonics, has provided us with the proper tools allowing us to obtain our objectives. Abbott Laboratories uses B-scan ultrasonics utilizing a pulse echo pitch catch technique to provide essential data on our pressure vessels. Equipment downtime is reduced because the nondestructive examination usually takes

  10. Determinants of injuries in passenger vessel accidents.

    Science.gov (United States)

    Yip, Tsz Leung; Jin, Di; Talley, Wayne K

    2015-09-01

    This paper investigates determinants of crew and passenger injuries in passenger vessel accidents. Crew and passenger injury equations are estimated for ferry, ocean cruise, and river cruise vessel accidents, utilizing detailed data of individual vessel accidents that were investigated by the U.S. Coast Guard during the time period 2001-2008. The estimation results provide empirical evidence (for the first time in the literature) that crew injuries are determinants of passenger injuries in passenger vessel accidents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Improved nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    An improved liquid metal nuclear reactor construction has a reactor core and a generally cylindrical reactor vessel for holding liquid metal coolant and housing the core within the pool. A generally cylindrical concrete containment structure surrounds the reactor vessel and a central support pedestal is anchored to the containment structure base mat and supports the bottom wall of the reactor vessel and the reactor core. The periphery of the reactor vessel bore is supported by an annular structure which allows thermal expansion but not seismic motion of the vessel, and a bed of thermally insulating material uniformly supports the vessel base whilst allowing expansion thereof. A guard ring prevents lateral seismic motion of the upper end of the reactor vessel. The periphery of the core is supported by an annular structure supported by the vessel base and keyed to the vessel wall so as to be able to expand but not undergo seismic motion. A deck is supported on the containment structure above the reactor vessel open top by annular bellows, the deck carrying the reactor control rods such that heating of the reactor vessel results in upward expansion against the control rods. (author)

  12. Final processing vessel for radioactive waste

    International Nuclear Information System (INIS)

    Tejima, Takaya; Hiraki, Akimitsu.

    1989-01-01

    An inorganic inner layer comprising dense inorganic material such as organic polymer-impregnated concretes is formed to about 10 - 50 mm in average thickness at the inside of a metal vessel. Further, the surface of the vessel is formed as a flat surface with no or only small reinforcing protrusions. Thus, if the final processing vessel should be dropped during transportation or handling by mistake, since impact shocks do not concentrate to protrusions as usual, no local stress concentration occurs to the inorganic inner liner layer. Accordingly, the risk of rapture can be reduced greatly. Further, since impact shock resistance layer put between the metal vessel and the inorganic inner liner layer absorbs shocks, a further sufficient strength can be obtained against dropping accident. (T.M.)

  13. Scaled Testing to Evaluate Pulse Jet Mixer Performance in Waste Treatment Plant Mixing Vessels

    International Nuclear Information System (INIS)

    Fort, James A.; Meyer, Perry A.; Bamberger, Judith A.; Enderlin, Carl W.; Scott, Paul A.; Minette, Michael J.; Gauglitz, Phillip A.

    2010-01-01

    The Waste Treatment and Immobilization Plant (WTP) at Hanford is being designed and built to pre-treat and vitrify the waste in Hanford's 177 underground waste storage tanks. Numerous process vessels will hold waste at various stages in the WTP. These vessels have pulse jet mixer (PJM) systems. A test program was developed to evaluate the adequacy of mixing system designs in the solids-containing vessels in the WTP. The program focused mainly on non-cohesive solids behavior. Specifically, the program addressed the effectiveness of the mixing systems to suspend settled solids off the vessel bottom, and distribute the solids vertically. Experiments were conducted at three scales using various particulate simulants. A range of solids loadings and operational parameters were evaluated, including jet velocity, pulse volume, and duty cycle. In place of actual PJMs, the tests used direct injection from tubes with suction at the top of the tank fluid. This gave better control over the discharge duration and duty cycle and simplified the facility requirements. The mixing system configurations represented in testing varied from 4 to 12 PJMs with various jet nozzle sizes. In this way the results collected could be applied to the broad range of WTP vessels with varying geometrical configurations and planned operating conditions. Data for 'just-suspended velocity', solids cloud height, and solids concentration vertical profile were collected, analyzed, and correlated. The correlations were successfully benchmarked against previous large-scale test results, then applied to the WTP vessels using reasonable assumptions of anticipated waste properties to evaluate adequacy of the existing mixing system designs.

  14. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  15. EDS V25 containment vessel explosive qualification test report.

    Energy Technology Data Exchange (ETDEWEB)

    Rudolphi, John Joseph

    2012-04-01

    The V25 containment vessel was procured by the Project Manager, Non-Stockpile Chemical Materiel (PMNSCM) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the first EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel based on the Code Case is nine (9) pounds TNT-equivalent for up to 637 detonations. This limit is an increase from the 4.8 pounds TNT-equivalency rating for previous vessels. This report describes the explosive qualification tests that were performed in the vessel as part of the process for qualifying the vessel for explosive use. The tests consisted of a 11.25 pound TNT equivalent bare charge detonation followed by a 9 pound TNT equivalent detonation.

  16. Results and analysis of reactor-material experiments on ex-vessel corium quench and dispersal

    International Nuclear Information System (INIS)

    Spencer, B.W.; McUmber, L.M.; Sienicki, J.J.; Squarer, D.

    1984-01-01

    Results of reactor-material experiments and related analysis are described in which molten corium is injected into a mock-up of the reactor cavity region of a PWR. The experiments address ex-vessel interactions such as steam generation (for those cases in which water is present), water and corium dispersal from the cavity, hydrogen generation, direct atmosphere heating by dispersed corium, and debris characterization. Test results indicate efficiencies of steam generation by corium quench ranging up to 65%. Corium sweepout of up to 62% of the injected material was found for those conditions in which steam generation flowrate was augmented by vessel blowdown. The dispersed corium caused very little direct heating of the atmosphere for the configuration employing a trap at the exit of the cavity-to-containment pathway. Corium sweepout phenomena were modeled for high-pressure blowdown conditions, and the results applied to the full-size reactor system predict essentially complete sweepout of corium from the reactor cavity

  17. Guidelines for pressure vessel safety assessment

    Science.gov (United States)

    Yukawa, S.

    1990-04-01

    A technical overview and information on metallic pressure containment vessels and tanks is given. The intent is to provide Occupational Safety and Health Administration (OSHA) personnel and other persons with information to assist in the evaluation of the safety of operating pressure vessels and low pressure storage tanks. The scope is limited to general industrial application vessels and tanks constructed of carbon or low alloy steels and used at temperatures between -75 and 315 C (-100 and 600 F). Information on design codes, materials, fabrication processes, inspection and testing applicable to the vessels and tanks are presented. The majority of the vessels and tanks are made to the rules and requirements of ASME Code Section VIII or API Standard 620. The causes of deterioration and damage in operation are described and methods and capabilities of detecting serious damage and cracking are discussed. Guidelines and recommendations formulated by various groups to inspect for the damages being found and to mitigate the causes and effects of the problems are presented.

  18. Comparison of vessel enhancement algorithms applied to time-of-flight MRA images for cerebrovascular segmentation.

    Science.gov (United States)

    Phellan, Renzo; Forkert, Nils D

    2017-11-01

    Vessel enhancement algorithms are often used as a preprocessing step for vessel segmentation in medical images to improve the overall segmentation accuracy. Each algorithm uses different characteristics to enhance vessels, such that the most suitable algorithm may vary for different applications. This paper presents a comparative analysis of the accuracy gains in vessel segmentation generated by the use of nine vessel enhancement algorithms: Multiscale vesselness using the formulas described by Erdt (MSE), Frangi (MSF), and Sato (MSS), optimally oriented flux (OOF), ranking orientations responses path operator (RORPO), the regularized Perona-Malik approach (RPM), vessel enhanced diffusion (VED), hybrid diffusion with continuous switch (HDCS), and the white top hat algorithm (WTH). The filters were evaluated and compared based on time-of-flight MRA datasets and corresponding manual segmentations from 5 healthy subjects and 10 patients with an arteriovenous malformation. Additionally, five synthetic angiographic datasets with corresponding ground truth segmentation were generated with three different noise levels (low, medium, and high) and also used for comparison. The parameters for each algorithm and subsequent segmentation were optimized using leave-one-out cross evaluation. The Dice coefficient, Matthews correlation coefficient, area under the ROC curve, number of connected components, and true positives were used for comparison. The results of this study suggest that vessel enhancement algorithms do not always lead to more accurate segmentation results compared to segmenting nonenhanced images directly. Multiscale vesselness algorithms, such as MSE, MSF, and MSS proved to be robust to noise, while diffusion-based filters, such as RPM, VED, and HDCS ranked in the top of the list in scenarios with medium or no noise. Filters that assume tubular-shapes, such as MSE, MSF, MSS, OOF, RORPO, and VED show a decrease in accuracy when considering patients with an AVM

  19. Model tests for prestressed concrete pressure vessels

    International Nuclear Information System (INIS)

    Stoever, R.

    1975-01-01

    Investigations with models of reactor pressure vessels are used to check results of three dimensional calculation methods and to predict the behaviour of the prototype. Model tests with 1:50 elastic pressure vessel models and with a 1:5 prestressed concrete pressure vessel are described and experimental results are presented. (orig.) [de

  20. Crack propagation on spherical pressure vessels

    International Nuclear Information System (INIS)

    Lebey, J.; Roche, R.

    1975-01-01

    The risk presented by a crack on a pressure vessel built with a ductile steel cannot be well evaluated by simple application of the rules of Linear Elastic Fracture Mechanics, which only apply to brittle materials. Tests were carried out on spherical vessels of three different scales built with the same steel. Cracks of different length were machined through the vessel wall. From the results obtained, crack initiation stress (beginning of stable propagation) and instable propagation stress may be plotted against the lengths of these cracks. For small and medium size, subject to ductile fracture, the resulting curves are identical, and may be used for ductile fracture prediction. Brittle rupture was observed on larger vessels and crack propagation occurred at lower stress level. Preceedings curves are not usable for fracture analysis. Ultimate pressure can be computed with a good accuracy by using equivalent energy toughness, Ksub(1cd), characteristic of the metal plates. Satisfactory measurements have been obtained on thin samples. The risks of brittle fracture may then judged by comparing Ksub(1cd) with the calculated K 1 value, in which corrections for vessel shape are taken into account. It is thus possible to establish the bursting pressure of cracked spherical vessels, with the help of two rules, one for brittle fracture, the other for ductile instability. A practical method is proposed on the basis of the work reported here

  1. Improvement of shipborne sky radiometer and its demonstration aboard the Antarctic research vessel Shirase

    Directory of Open Access Journals (Sweden)

    Noriaki Tanaka

    2014-11-01

    Full Text Available The sun-tracking performance of a shipborne sky radiometer was improved to attain accurate aerosol optical thickness (AOT from direct solar measurements on a pitching and rolling vessel. Improvements were made in the accuracy of sun-pointing measurements, field-of-view expansion, sun-tracking speed, and measurement method. Radiometric measurements of direct solar and sky brightness distribution were performed using the shipborne sky radiometer onboard the Antarctic research vessel (R/V Shirase during JARE-51 (2009-2010 and JARE-52 (2010-2011. The temporal variation of signal intensity measured by the radiometer under cloudless conditions was smooth, demonstrating that the radiometer could measure direct sunlight onboard the R/V. AOT at 500 nm ranged from 0.01 to 0.34, and values over Southeast Asia and over the western Pacific Ocean in spring were higher than those over other regions. The Angstrom exponent ranged from -0.06 to 2.00, and values over Southeast Asia and off the coast near Sydney were the highest. The improved shipborne sky radiometer will contribute to a good understanding of the nature of aerosols over the ocean.

  2. Bone marrow blood vessels: normal and neoplastic niche

    Directory of Open Access Journals (Sweden)

    Saeid Shahrabi

    2016-11-01

    Full Text Available Blood vessels are among the most important factors in the transport of materials such as nutrients and oxygen. This study will review the role of blood vessels in normal bone marrow hematopoiesis as well as pathological conditions like leukemia and metastasis. Relevant literature was identified by a Pubmed search (1992-2016 of English-language papers using the terms bone marrow, leukemia, metastasis, and vessel. Given that blood vessels are conduits for the transfer of nutrients, they create a favorable situation for cancer cells and cause their growth and development. On the other hand, blood vessels protect leukemia cells against chemotherapy drugs. Finally, it may be concluded that the vessels are an important factor in the development of malignant diseases.

  3. Vessel calibration for accurate material accountancy at RRP

    International Nuclear Information System (INIS)

    Yanagisawa, Yuu; Ono, Sawako; Iwamoto, Tomonori

    2004-01-01

    RRP has a 800t·Upr capacity a year to re-process, where would be handled a large amount of nuclear materials as solution. A large scale plant like RRP will require accurate materials accountancy system, so that the vessel calibration with high-precision is very important as initial vessel calibration before operation. In order to obtain the calibration curve, it is needed well-known each the increment volume related with liquid height. Then we performed at least 2 or 3 times run with water for vessel calibration and careful evaluation for the calibration data should be needed. We performed vessel calibration overall 210 vessels, and the calibration of 81 vessels including IAT and OAT were held under presence of JSGO and IAEA inspectors taking into account importance on the material accountancy. This paper describes outline of the initial vessel calibration and calibration results based on back pressure measurement with dip tubes. (author)

  4. 46 CFR 90.10-16 - Industrial vessel.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial vessel. 90.10-16 Section 90.10-16 Shipping... PROVISIONS Definition of Terms Used in This Subchapter § 90.10-16 Industrial vessel. This term means every vessel which by reason of its special outfit, purpose, design, or function engages in certain industrial...

  5. Equipment for decontamination of inner vessel surfaces featuring sound or ultrasound transducer on float inside liquid-filled vessel

    International Nuclear Information System (INIS)

    Bar, J.; Straka, M.

    1982-01-01

    The equipment for the decontamination of the inner surfaces of vessels consists of an immersion float which is provided with a screw, an electric motor, a rudder and at least one float chamber, and a remotely controlled valve. The float is provided with a power source, a high frequency a.c. current generator and a control panel outside the vessel. The float is connected to parts of the equipment outside the vessel by a multi-core cable. The immersion float may also be provided with a detector for measuring the quantity of ionizing radiation whose display is placed outside the vessel being decontaminated. (B.S.)

  6. Discharge of Non-Reactive Fluids from Vessels

    Directory of Open Access Journals (Sweden)

    M. Castier

    Full Text Available Abstract This paper presents simulations of discharges from pressure vessels that consistently account for non-ideal fluid behavior in all the required thermodynamic properties and individually considers all the chemical components present. The underlying assumption is that phase equilibrium occurs instantaneously inside the vessel and, thus, the dynamics of the fluid in the vessel comprises a sequence of equilibrium states. The formulation leads to a system of differential-algebraic equations in which the component mass balances and the energy balance are ordinary differential equations. The algebraic equations account for the phase equilibrium conditions inside the vessel and at the discharge point, and for sound speed calculations. The simulator allows detailed predictions of the condition inside the vessel and at the discharge point as a function of time, including the flow rate and composition of the discharge. The paper presents conceptual applications of the simulator to predict the effect of leaks from vessels containing mixtures of light gases and/or hydrocarbons and comparisons to experimental data.

  7. Pressure vessel integrity and weld inspection procedure

    International Nuclear Information System (INIS)

    Solomon, K.A.; Okrent, D.; Kastenberg, W.E.

    1975-01-01

    The primary objective of this paper is to develop a simple methodology which, when coupled with existing observations on pressure vessel behavior, provides an inter-relation between pressure vessel integrity, and the parameters of the in-service inspection program, including inspection sample size, frequency and efficiency. A modified Markov process is employed and a computer code was written to obtain numerical results. The Markov process mathematically describes the following physical events. In a nuclear reactor pressure vessel weld, some defects may exist prior to the zeroth inspection (i.e., prior to vessel operation). During the zeroth inspection and repair processes, some of these defects are removed. During the first cycle of vessel operation, the existing defects may grow and some new defects may be generated. Those defects that are found at the first (and succeeding) inspection interval and warrant repair, are repaired. The above process continues through several operating cycles to the end of vessel life. During any inspection, only a portion of the welds may be inspected, and with less than perfect efficiency

  8. Nuclear power plant pressure vessels. Control of piping

    International Nuclear Information System (INIS)

    2000-01-01

    The guide presents requirements for the pipework of nuclear facilities in Finland. According to the section 117 of the Finnish Nuclear Energy Degree (161/88), the Radiation and Nuclear Safety Authority of Finland (STUK) controls the pressure vessels of nuclear facilities in accordance with the Nuclear Energy Act (990/87) and, to the extent applicable in accordance with the Act of Pressure Vessels (98/73) and the rules and regulations issued by the virtue of these. In addition STUK is an inspecting authority of pressure vessels of nuclear facilities in accordance with the Pressure Vessel Degree (549/1973). According to the section of the Pressure Vessel Degree, a pressure vessel is a steam boiler, pressure container, pipework of other such appliance in which the pressure is above or may come to exceed the atmospheric pressure. Guide YVL 3.0 describes in general terms how STUK controls pressure vessels. STUK controls Safety Class 1, 2 and 3 piping as well as Class EYT (non-nuclear) and their support structures in accordance with this guide and applies the provisions of the Decision of the Ministry of Trade and Industry on piping (71/1975) issued by virtue of the Pressure Vessel Decree

  9. Fast-neutron nuclear reactor vessel

    International Nuclear Information System (INIS)

    Presciuttini, L.

    1984-01-01

    The reactor vessel comprises a cylindrical shell, of which axis is vertical, coupled at its lower part with a dished bottom. The reactor core rests on a support plate bearing on the bottom of the vessel. The above dished bottom comprises a spherical sector having the same radius and the same axis as the cylindrical shell and joining the lower part of the shell, and a spherical head of which radius is a little more important than the spherical sector one. A cylindrical support for the reactor core is attached to the vessel at the joint between the two dished sections. The invention applies more particularly to integrated type reactors cooled by liquid sodium [fr

  10. Application of annealing for WWER vessels life extension

    International Nuclear Information System (INIS)

    Badanin, V.I.; Gorynin, I.V.; Nickolaev, V.A.; Dragunov, Y.G.; Fedorov, V.G.

    1989-01-01

    Safe operation of NPP is greatly dependent on the guarantee of reactor vessel brittle failure strength with account for the effect of radiation embrittlement of vessel material. Recovery of irradiated material properties is principally important way to extend radiation life of reactor vessel. The aim of this report is to demonstrate the efficiency of annealing for recovery of vessel material properties and extension of its service-life

  11. Proof testing of an explosion containment vessel

    Energy Technology Data Exchange (ETDEWEB)

    Esparza, E.D. [Esparza (Edward D.), San Antonio, TX (United States); Stacy, H.; Wackerle, J. [Los Alamos National Lab., NM (United States)

    1996-10-01

    A steel containment vessel was fabricated and proof tested for use by the Los Alamos National Laboratory at their M-9 facility. The HY-100 steel vessel was designed to provide total containment for high explosives tests up to 22 lb (10 kg) of TNT equivalent. The vessel was fabricated from an 11.5-ft diameter cylindrical shell, 1.5 in thick, and 2:1 elliptical ends, 2 in thick. Prior to delivery and acceptance, three types of tests were required for proof testing the vessel: a hydrostatic pressure test, air leak tests, and two full design charge explosion tests. The hydrostatic pressure test provided an initial static check on the capacity of the vessel and functioning of the strain instrumentation. The pneumatic air leak tests were performed before, in between, and after the explosion tests. After three smaller preliminary charge tests, the full design charge weight explosion tests demonstrated that no yielding occurred in the vessel at its rated capacity. The blast pressures generated by the explosions and the dynamic response of the vessel were measured and recorded with 33 strain channels, 4 blast pressure channels, 2 gas pressure channels, and 3 displacement channels. This paper presents an overview of the test program, a short summary of the methodology used to predict the design blast loads, a brief description of the transducer locations and measurement systems, some of the hydrostatic test strain and stress results, examples of the explosion pressure and dynamic strain data, and some comparisons of the measured data with the design loads and stresses on the vessel.

  12. Prestressed concrete reactor vessel for the HHT-670 MW(e) demonstration plant. Pt.1. Design of the multi-cavity prestressed concrete reactor vessel with warm liner

    International Nuclear Information System (INIS)

    Lafitte, R.; Marchand, J.D.

    1979-01-01

    The design studies and tests described in this paper were undertaken as part of ''PROJECT HHT'', a German-Swiss joint effort for the development of high-temperature helium cooled reactors with direct-cycle turbine. The prestressed concrete reactor pressure vessel encloses the core of the reactor itself, the heat exchangers (coolers and recuperators), the helium turbine, the main helium circuit, all nuclear and thermal equipment, and auxiliary reactor cooling equipment. In order to make the liner accessible for inspection, no thermal insulation is provided between the coolant and the liner. The temperature of the helium in contact with the liner is limited to 200 0 C, under all normal operation conditions of the reactor. In the HHT reactor pressure vessel, the resisting structure is protected thermally by a layer of warm concrete between the liner and the structural prestressed concrete. The main features of this pressure vessel are the marked pressure differences in the cavities during normal operation, and the use of warm liner. The objectives of the reference design were chiefly related to the sizing up of the main structure, taking into account the modifications to be expected in the material characteristics as a result of the high temperatures developed

  13. Segmentation of hepatic artery in multi-phase liver CT using directional dilation and connectivity analysis

    Science.gov (United States)

    Wang, Lei; Schnurr, Alena-Kathrin; Zidowitz, Stephan; Georgii, Joachim; Zhao, Yue; Razavi, Mohammad; Schwier, Michael; Hahn, Horst K.; Hansen, Christian

    2016-03-01

    Segmentation of hepatic arteries in multi-phase computed tomography (CT) images is indispensable in liver surgery planning. During image acquisition, the hepatic artery is enhanced by the injection of contrast agent. The enhanced signals are often not stably acquired due to non-optimal contrast timing. Other vascular structure, such as hepatic vein or portal vein, can be enhanced as well in the arterial phase, which can adversely affect the segmentation results. Furthermore, the arteries might suffer from partial volume effects due to their small diameter. To overcome these difficulties, we propose a framework for robust hepatic artery segmentation requiring a minimal amount of user interaction. First, an efficient multi-scale Hessian-based vesselness filter is applied on the artery phase CT image, aiming to enhance vessel structures with specified diameter range. Second, the vesselness response is processed using a Bayesian classifier to identify the most probable vessel structures. Considering the vesselness filter normally performs not ideally on the vessel bifurcations or the segments corrupted by noise, two vessel-reconnection techniques are proposed. The first technique uses a directional morphological operator to dilate vessel segments along their centerline directions, attempting to fill the gap between broken vascular segments. The second technique analyzes the connectivity of vessel segments and reconnects disconnected segments and branches. Finally, a 3D vessel tree is reconstructed. The algorithm has been evaluated using 18 CT images of the liver. To quantitatively measure the similarities between segmented and reference vessel trees, the skeleton coverage and mean symmetric distance are calculated to quantify the agreement between reference and segmented vessel skeletons, resulting in an average of 0:55+/-0:27 and 12:7+/-7:9 mm (mean standard deviation), respectively.

  14. Research Vessel R/V Sikuliaq: A New Asset For The UNOLS Fleet

    Science.gov (United States)

    Whitledge, T. E.

    2012-12-01

    The research vessel R/V Sikuliaq is currently being constructed on behalf of the NSF to support future scientific studies in high latitude waters. The 261 foot global class vessel will be capable of breaking 2.5 foot thick ice at 2 knots with an endurance of 45 days at sea and cruising at 11 knots. The R/V Sikuliaq will have a beam of 52 feet and a draft of 18.9 feet that will carry 26 scientists and a crew of 20. Berthing accommodations are a combination of single/double rooms with one stateroom and the common areas of the vessel are designed for ADA access and accommodations. The total laboratory space (main, analytical, electronics, wet, upper, and Baltic room will be 2100 square feet. The 4360 square foot working deck that is approximately 70 feet in length will accommodate 2-4 vans and multiple science operations. The vessel design strives to have the lowest possible environmental impact, including a low underwater-radiated noise signature. The science systems are prescribed to be state-of-the-art for bottom mapping, over-the-side "hands free" gear handling, broad band communications and scientific walk-in freezer and environmental chamber. More details and photos of the construction progress are available on the website at www.sfos.uaf.edu/arrv. The shipyard schedule has a launch date of October 2012 and delivery to the University of Alaska Fairbanks in July 2013. Scientific operations following trials and testing is planned to start in January 2014. Questions about the science systems or vessel capabilities should be directed to Terry Whitledge (terry@ims.uaf.edu).;

  15. Reactor pressure vessel design

    International Nuclear Information System (INIS)

    Foehl, J.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. In chapter 2, the general principles of reactor pressure vessel design are elaborated. Crack and fracture initiation and propagation are treated in some detail

  16. Increase of cyclic durability of pressure vessels

    International Nuclear Information System (INIS)

    Vorona, V.A.; Zvezdin, Yu.I.

    1980-01-01

    The durability of multilayer pressure vessels under cyclic loading is compared with single-layer vessels. The relative conditional durability is calculated taking into account the assumption on the consequent destruction of layers and viewing a vessel wall as an indefinite plate. It is established that the durability is mainly determined by the number of layers and to a lesser degree depends on the relative size of the defect for the given layer thickness. The advantage of the multilayer vessels is the possibility of selecting layer materials so that to exclude the effect of agressive corrosion media on the strength [ru

  17. Methodological efficiency of reactor pressure vessel control samples programs and reliability of WWER vessels at the Ukraine NPP

    International Nuclear Information System (INIS)

    Kovbasenko, S.N.; Brednev, V.I.; Zinchenko, O.Ya.

    2000-01-01

    An analysis is made for the programs with the use of check specimens (CS) for reactor vessel (RV) control which is considered as the only method for estimating embrittlement in RV material and its operational capability. Advantages and disadvantages of the programs are noted. Other methods are developed and improved to estimate properties of RV metal and welded joints. It is shown that the most valid information about RV metal state can be obtained only by testing specimens prepared from templets cut directly from a RV wall in the region of reactor core. Ukrainian researchers designed the equipment and performed successful tests on templet cutting from the surface of the metal to study mechanical properties of critical pipelines [ru

  18. FLUOLE-2: An Experiment for PWR Pressure Vessel Surveillance

    Directory of Open Access Journals (Sweden)

    Thiollay Nicolas

    2016-01-01

    Full Text Available FLUOLE-2 is a benchmark-type experiment dedicated to 900 and 1450 MWe PWR vessels surveillance dosimetry. This two-year program started in 2014 and will end in 2015. It will provide precise experimental data for the validation of the neutron spectrum propagation calculation from core to vessel. It is composed of a square core surrounded by a stainless steel baffe and internals: PWR barrel is simulated by steel structures leading to different steel-water slides; two steel components stand for a surveillance capsule holder and for a part of the pressure vessel. Measurement locations are available on the whole experimental structure. The experimental knowledge of core sources will be obtained by integral gamma scanning measurements directly on fuel pins. Reaction rates measured by calibrated fission chambers and a large set of dosimeters will give information on the neutron energy and spatial distributions. Due to the low level neutron flux of EOLE ZPR a special, high efficiency, calibrated gamma spectrometry device will be used for some dosimeters, allowing to measure an activity as low as 7. 10−2 Bq per sample. 103mRh activities will be measured on an absolute calibrated X spectrometry device. FLUOLE-2 experiment goal is to usefully complete the current experimental benchmarks database used for the validation of neutron calculation codes. This two-year program completes the initial FLUOLE program held in 2006–2007 in a geometry representative of 1300 MWe PWR.

  19. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  20. High-resolution 3D Magnetic Resonance angiography in the evaluation of neck vessels and intracranial circulation

    International Nuclear Information System (INIS)

    Villa, A.; Di Guglielmo, L.; Campani, R.; Nicolato, A.; D'Amato, M.; Rodriguez y Balena, R.

    1991-01-01

    Magnetic Resonance Angiography (MRA) is a modern vascular imaging technique which allows the non-invasive and direct imaging of vessels. The authors aimed at evaluating the diagnostic accuracy of MRA in the study of pathologic conditions in the neck and intracranial vessels; spatial resolution of the technique was also investigated. Twenty-four healthy volunteers and 82 patients suffering from various diseases of the head and neck vessels were included in the study. First of all, MRA capabilities ware investigated in visualizing normal vessels of both neck and intracranial circle. The diagnostic accuracy of the method was then evaluated in the study of vascular diseases, and the results compared with conventional/digital angiographic findings. The comparison demonstrated how stenoses and atherosclerotic plaques tend to be overestimated by MRA because of technical artifacts inherent to the technique itself, whereas vascular ulcerations and aneurysms are frequently underestimated. However, this data was steady and therefore evaluable- the exact knowledge of the artifacts making diagnosis reliable. The diagnostic and technical problems relative to the various vascular diseases are discussed. Finally, several hypotheses of diagnostic iter are suggested

  1. Standard Guide for Application of Neutron Transport Methods for Reactor Vessel Surveillance, E706 (IID)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 Need for Neutronics Calculations—An accurate calculation of the neutron fluence and fluence rate at several locations is essential for the analysis of integral dosimetry measurements and for predicting irradiation damage exposure parameter values in the pressure vessel. Exposure parameter values may be obtained directly from calculations or indirectly from calculations that are adjusted with dosimetry measurements; Guide E944 and Practice E853 define appropriate computational procedures. 1.2 Methodology—Neutronics calculations for application to reactor vessel surveillance encompass three essential areas: (1) validation of methods by comparison of calculations with dosimetry measurements in a benchmark experiment, (2) determination of the neutron source distribution in the reactor core, and (3) calculation of neutron fluence rate at the surveillance position and in the pressure vessel. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is th...

  2. Baking results of KSTAR vacuum vessel

    International Nuclear Information System (INIS)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M.

    2009-01-01

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported

  3. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1977-01-01

    According to the present invention there is provided an improved arrangement for supporting a reactor vessel within a containment structure against static and dynamic vertical loadings capable of being imposed as a result of a serious accident as well as during periods of normal plant operation. The support arrangement of the invention is, at the same time, capable of accommodating radial displacements that normally occur between the reactor vessel and the containment structure due to operational transients. The arrangement comprises a plurality of vertical columns connected between the reactor vessel and a support base within the containment structure. The columns are designed to accommodate relative displacements between the vessel and the containment structure by flexing. This eliminates the need for relative sliding movements and thus enables the columns to be securely fixed to the vessel. This elimination of a provision for relative sliding movements avoids the spaces or gaps between the retention members and the retained elements as occurred in prior art arrangements and, concomitantly, the danger of establishing impact forces on the retention members in the event of an accident is reduced. (author)

  4. Baking results of KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported.

  5. Segmentation and packaging reactor vessels internals

    International Nuclear Information System (INIS)

    Boucau, Joseph

    2014-01-01

    Document available in abstract form only, full text follows: With more than 25 years of experience in the development of reactor vessel internals and reactor vessel segmentation and packaging technology, Westinghouse has accumulated significant know-how in the reactor dismantling market. The primary challenges of a segmentation and packaging project are to separate the highly activated materials from the less-activated materials and package them into appropriate containers for disposal. Since disposal cost is a key factor, it is important to plan and optimize waste segmentation and packaging. The choice of the optimum cutting technology is also important for a successful project implementation and depends on some specific constraints. Detailed 3-D modeling is the basis for tooling design and provides invaluable support in determining the optimum strategy for component cutting and disposal in waste containers, taking account of the radiological and packaging constraints. The usual method is to start at the end of the process, by evaluating handling of the containers, the waste disposal requirements, what type and size of containers are available for the different disposal options, and working backwards to select a cutting method and finally the cut geometry required. The 3-D models can include intelligent data such as weight, center of gravity, curie content, etc, for each segmented piece, which is very useful when comparing various cutting, handling and packaging options. The detailed 3-D analyses and thorough characterization assessment can draw the attention to material potentially subject to clearance, either directly or after certain period of decay, to allow recycling and further disposal cost reduction. Westinghouse has developed a variety of special cutting and handling tools, support fixtures, service bridges, water filtration systems, video-monitoring systems and customized rigging, all of which are required for a successful reactor vessel internals

  6. DIRECT-CYCLE, BOILING-WATER NUCLEAR REACTOR

    Science.gov (United States)

    Harrer, J.M.; Fromm, L.W. Jr.; Kolba, V.M.

    1962-08-14

    A direct-cycle boiling-water nuclear reactor is described that employs a closed vessel and a plurality of fuel assemblies, each comprising an outer tube closed at its lower end, an inner tube, fuel rods in the space between the tubes and within the inner tube. A body of water lying within the pressure vessel and outside the fuel assemblies is converted to saturated steam, which enters each fuel assembly at the top and is converted to superheated steam in the fuel assembly while it is passing therethrough first downward through the space between the inner and outer tubes of the fuel assembly and then upward through the inner tube. (AEC)

  7. Assessment of W7-X plasma vessel pressurisation in case of LOCA taking into account in-vessel components

    Energy Technology Data Exchange (ETDEWEB)

    Urbonavičius, E., E-mail: Egidijus.Urbonavicius@lei.lt; Povilaitis, M., E-mail: Mantas.Povilaitis@lei.lt; Kontautas, A., E-mail: Aurimas.Kontautas@lei.lt

    2015-11-15

    Highlights: • Analysis of the vacuum vessel response to the LOCA in W7-X was performed using lumped-parameter codes COCOSYS and ASTEC. • Benchmarking of the results received with two codes provides more confidence in results and helps in identification of possible important differences in the modelling. • The performed analysis answered the questions set in the installed plasma vessel venting system during overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. • Differences in time until opening the burst disk observed in ASTEC and COCOSYS results are caused by differences in heat transfer modelling. - Abstract: This paper presents the analysis of W7-X vacuum vessel response taking into account in-vessel components. A detailed analysis of the vacuum vessel response to the loss of coolant accident was performed using lumped-parameter codes COCOSYS and ASTEC. The performed analysis showed that the installed plasma vessel venting system prevents overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. The performed analysis revealed differences in heat transfer modelling implemented in ASTEC and COCOSYS computer codes, which require further investigation to justify the correct approach for application to fusion facilities.

  8. Assessment of W7-X plasma vessel pressurisation in case of LOCA taking into account in-vessel components

    International Nuclear Information System (INIS)

    Urbonavičius, E.; Povilaitis, M.; Kontautas, A.

    2015-01-01

    Highlights: • Analysis of the vacuum vessel response to the LOCA in W7-X was performed using lumped-parameter codes COCOSYS and ASTEC. • Benchmarking of the results received with two codes provides more confidence in results and helps in identification of possible important differences in the modelling. • The performed analysis answered the questions set in the installed plasma vessel venting system during overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. • Differences in time until opening the burst disk observed in ASTEC and COCOSYS results are caused by differences in heat transfer modelling. - Abstract: This paper presents the analysis of W7-X vacuum vessel response taking into account in-vessel components. A detailed analysis of the vacuum vessel response to the loss of coolant accident was performed using lumped-parameter codes COCOSYS and ASTEC. The performed analysis showed that the installed plasma vessel venting system prevents overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. The performed analysis revealed differences in heat transfer modelling implemented in ASTEC and COCOSYS computer codes, which require further investigation to justify the correct approach for application to fusion facilities.

  9. Ultrasonic testing of electron beam closure weld on pressure vessel

    International Nuclear Information System (INIS)

    Andrews, R.W.

    1975-01-01

    One of the special products manufactured at the General Electric Neutron Devices Department (GEND) is a small stainless steel vessel designed to hold a component under high pressure for long periods. The vessel is a thick-walled cylinder with a threaded receptacle into which a plug is screwed and welded after receiving the unit to be tested. The test cavity is then pressurized through a small diameter opening in the bottom and that opening is welded closed. When x-ray inspection techniques did not reveal defective welds at the threaded plug in a pressured vessel, occasional ''leakers'' occurred. With normal equipment tolerances, the electron beam spike tends to wander from the desired path, particularly at the root of the weld. Ultrasonic techniques were used to successfully inspect the weld. The testing technique is based on the observation that ultrasonic energy is reflected from the unwelded screw threads and not from the regions where the threads are completely fused together by welding. Any gas pore or any threaded region outside the weld bead can produce an echo. The units are rotated while the ultrasonic transducer travels in a direction parallel to the axis of rotation and toward the welded end. This produces a helical scan which is converted to a two-dimensional presentation in which incomplete welds can be noted. (U.S.)

  10. Development of Catamaran Fishing Vessel

    Directory of Open Access Journals (Sweden)

    A. Jamaluddin

    2010-11-01

    Full Text Available Multihull due to a couple of advantages has been the topic of extensive research work in naval architecture. In this study, a series of investigation of fishing vessel to save fuel energy was carried out at ITS. Two types of ship models, monohull (round bilge and hard chine and catamaran, a boat with two hulls (symmetrical and asymmetrical were developed. Four models were produced physically and numerically, tested (towing tank and simulated numerically (CFD code. The results of the two approaches indicated that the catamaran mode might have drag (resistance smaller than those of monohull at the same displacement. A layout of catamaran fishing vessel, proposed here, indicates the freedom of setting the deck equipments for fishing vessel.

  11. Metallurgy of steels for PWR pressure vessels

    International Nuclear Information System (INIS)

    Kepka, M.; Mocek, J.; Barackova, L.

    1980-01-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure. (B.S.)

  12. Metallurgy of steels for PWR pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Kepka, M; Mocek, J; Barackova, L [Skoda, Plzen (Czechoslovakia)

    1980-09-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure.

  13. Adaptable three-dimensional Monte Carlo modeling of imaged blood vessels in skin

    Science.gov (United States)

    Pfefer, T. Joshua; Barton, Jennifer K.; Chan, Eric K.; Ducros, Mathieu G.; Sorg, Brian S.; Milner, Thomas E.; Nelson, J. Stuart; Welch, Ashley J.

    1997-06-01

    In order to reach a higher level of accuracy in simulation of port wine stain treatment, we propose to discard the typical layered geometry and cylindrical blood vessel assumptions made in optical models and use imaging techniques to define actual tissue geometry. Two main additions to the typical 3D, weighted photon, variable step size Monte Carlo routine were necessary to achieve this goal. First, optical low coherence reflectometry (OLCR) images of rat skin were used to specify a 3D material array, with each entry assigned a label to represent the type of tissue in that particular voxel. Second, the Monte Carlo algorithm was altered so that when a photon crosses into a new voxel, the remaining path length is recalculated using the new optical properties, as specified by the material array. The model has shown good agreement with data from the literature. Monte Carlo simulations using OLCR images of asymmetrically curved blood vessels show various effects such as shading, scattering-induced peaks at vessel surfaces, and directionality-induced gradients in energy deposition. In conclusion, this augmentation of the Monte Carlo method can accurately simulate light transport for a wide variety of nonhomogeneous tissue geometries.

  14. Remote maintenance of in-vessel components in Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Loesser, G.D.; Heitzenroeder, P.; Kungl, D.; Dylla, H.F.; Cerdan, G.

    1990-01-01

    The Tokamak Fusion Test Reactor (TFTR) will generate a total of 3 x 10 21 neutrons during its planned D-T operational period. A maintenance manipulator has been designed and tested to minimize personnel radiation during in-vessel maintenance activities. Its functions include visual inspection, first-wall tile replacement, cleaning, diagnostics calibrations and leak detection. To meet these objectives, the TFTR maintenance manipulator is required to be operable in the TFTR high vacuum environment, typically -8 torr, ( -6 Pa). Geometrically, the manipulator must extend 180 0 in either direction around the torus to assure complete coverage of the vessel first-wall. The manipulator consists of a movable carriage, and movable articulated link sections which are driven by electrical actuators. The boom has vertical load capacity of 455 kg and lateral load capacity of 46 kg. The boom can either be fitted with a general inspection arm or dextrous slave arms. The general inspection arm is designed to hold the leak detector and an inspection camera; it is capable of rotation along two axes and has a linkage system which permits motion normal to the vacuum vessel wall. All systems except the dextrous slave arms are operable in a vacuum. (author)

  15. A higher-order tensor vessel tractography for segmentation of vascular structures.

    Science.gov (United States)

    Cetin, Suheyla; Unal, Gozde

    2015-10-01

    A new vascular structure segmentation method, which is based on a cylindrical flux-based higher order tensor (HOT), is presented. On a vessel structure, the HOT naturally models branching points, which create challenges for vessel segmentation algorithms. In a general linear HOT model embedded in 3D, one has to work with an even order tensor due to an enforced antipodal-symmetry on the unit sphere. However, in scenarios such as in a bifurcation, the antipodally-symmetric tensor embedded in 3D will not be useful. In order to overcome that limitation, we embed the tensor in 4D and obtain a structure that can model asymmetric junction scenarios. During construction of a higher order tensor (e.g. third or fourth order) in 4D, the orientation vectors lie on the unit 3-sphere, in contrast to the unit 2-sphere in 3D tensor modeling. This 4D tensor is exploited in a seed-based vessel segmentation algorithm, where the principal directions of the 4D HOT is obtained by decomposition, and used in a HOT tractography approach. We demonstrate quantitative validation of the proposed algorithm on both synthetic complex tubular structures as well as real cerebral vasculature in Magnetic Resonance Angiography (MRA) datasets and coronary arteries from Computed Tomography Angiography (CTA) volumes.

  16. Variation and treatment of vessels in laparoscopic right hemicolectomy.

    Science.gov (United States)

    Ye, Kai; Lin, Jianan; Sun, Yafeng; Wu, Yiyang; Xu, Jianhua; He, Songbing

    2018-03-01

    With the introduction of complete mesocolic excision (CME) and the application of laparoscopic technique, surgery for colon cancer has become more standardized and the curative effect has improved [1]. The key points in laparoscopic right hemicolectomy are high ligation of main vessels and root dissection of lymph nodes. The wide range of variations in vascular architecture and intraoperative bleeding are common causes of prolonged surgical time, wound hemorrhage, and even transfer to the opening operation. The superior mesenteric vein (SMV) is the most important anatomical landmark in CME for the right colon, and guides all the steps of lymph node dissection. The SMV appears as a pale blue bulge on laparoscopy, which enables accurate positioning. The ileocolic vessel pedicle is relatively constant and facilitates accurate positioning. The intersection of the ileocolic vessel pedicle and the SMV is the optimal starting point in laparoscopic right hemicolectomy using a medial-to-lateral approach. A sheath with an avascular plane can be reached after opening the SMV vascular sheath, which results in less bleeding and enables vascular root and thorough lymph node dissection. The first step is to manage the ileocolic vessels. The ileocolic artery (ICA) is located anterior to the ileocolic vein (ICV) for about one-third of the incidence. The ileocolic vessels are relatively long and are easy to work with. In the vast majority of cases, the ICV drains into the SMV, and into the gastrocolic trunk (GCT) in about 2.5% of cases. The reported incidence of a right colic artery (RCA) is controversial; the RCA is absent in about 50% of cases and often crosses the SMV. The right colic vein (RCV) usually drains into the GCT, but sometimes drains directly into the SMV. The middle colic vessels have great variability and a close anatomical relationship with the pancreas, duodenum, and GCT. Moreover, the transverse colon and mesentery are long, and root positioning and processing of

  17. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  18. Design and issues of the ITER in-vessel components: ITER Joint central team and home teams

    International Nuclear Information System (INIS)

    Parker, R.R.

    1998-01-01

    This paper surveys the status of the design of the in-vessel components for ITER, in particular the major components, namely the vacuum vessel, blanket and first wall, and divertor, and the interface of selected ancillary systems such as those used for RF heating and current drive, and for diagnostics. The vacuum vessel is a double-walled structure constructed from two toroidal shells joined by ribs. The space between the skins is filled with shield plates directly cooled by water. The structural material is 316 LN IG (ITER grade). Toroidal supports joining the vessel midplane ports with the TF structure limit possible differential toroidal displacements, as might occur due to seismic or vertical displacement events (VDEs). A variety of load conditions corresponding to normal and off-normal loads have been considered and in all cases peak vessel stresses are within allowables. The blanket system consists of approximately 700 modules, each weighing ∝4 t. The integrated first wall consists of a beryllium-tiled copper mat bonded to the water-cooled SS shield block. The copper mat functions as a heat sink and has imbedded in it an array of SS tubes providing water cooling. The modules are mechanically attached to a toroidal backplate. Loads due to centered disruptions are reacted via hoop stress in the backplate, whereas net vertical and horizontal loads such as those arising from VDEs are transferred through the backplate and divertor supports to the vessel. (orig.)

  19. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  20. Swimming performance of a bio-inspired robotic vessel with undulating fin propulsion.

    Science.gov (United States)

    Liu, Hanlin; Curet, Oscar M

    2018-06-18

    Undulatory fin propulsion exhibits high degree of maneuver control -- an ideal for underwater vessels exploring complex environments. In this work, we developed and tested a self-contained, free-swimming robot with a single undulating fin running along the length of the robot, which controls both forward motion and directional maneuvers. We successfully replicated several maneuvers including forward swimming, reversed motion, diving, station-keeping and vertical swimming. For each maneuver, a series of experiments were performed as a function of fin frequency, wavelength and traveling wave direction to measure swimming velocities, orientation angles and mean power consumption. In addition, three-dimensional flow fields were measured during forward swimming and station-keeping using volumetric particle image velocimetry (PIV). The efficiency for forward swimming was compared using three metrics: cost of transport, wave efficiency and Strouhal number. The results indicate that the cost of transport exhibits a V-shape trend with the minimum value at low swimming velocity. The robot can reach optimal wave efficiency and locomotor performance at a range of 0.2 to 0.4 St. Volumetric PIV data reveal the shed of vortex tubes generated by the fin during forward swimming and station keeping. For forward swimming, a series of vortex tubes are shed off the fin edge with a lateral and downward direction with respect to the longitudinal axis of the fin. For station keeping, flow measurements suggest that the vortex tubes are shed at the mid-section of the fin while the posterior and anterior segment of the vortex stay attached to the fin. These results agree with the previous vortex structures based on simulations and 2D PIV. The further development of this vessel with high maneuverability and station keeping performance can be used for oceanography, coastal exploration, defense, oil industry and other marine industries where operations are unsafe or impractical for divers or

  1. Reactors with pressure vessel in pre-stressed concrete

    International Nuclear Information System (INIS)

    Devillers, Christian; Lafore, Pierre

    1964-12-01

    After having proposed a general description of the evolution of the general design of reactors with a vessel in pre-stressed concrete, this report outlines the interest of this technical solution of a vessel in pre-stressed concrete with integrated exchangers, which is to replace steel vessel. This solution is presented as much safer. The authors discuss the various issues related to protection: inner and outer biological protection of the vessel, material protection (against heating, steel irradiation, Wigner effect, and moderator radiolytic corrosion). They report the application of calculation methods: calculation of vessel concrete heating, study of the intermediate zone in integrated reactors, neutron spectrum and flows in the core of a graphite pile

  2. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  3. How to replace a reactor pressure vessel

    International Nuclear Information System (INIS)

    Huber, R.

    1996-01-01

    A potential life extending procedure for a nuclear reactor after, say, 40 years of service life, might in some circumstances be the replacement of the reactor pressure vessel. Neutron induced degradation of the vessel might make replacement by one of a different material composition desirable, for example. Although the replacement of heavy components, such as steam generators, has been possible for many years, the pressure vessel presents a much more demanding task if only because it is highly irradiated. Some preliminary feasibility studies by Siemens are reported for the two removal strategies that might be considered. These are removal of the entire pressure vessel in one piece and dismantling it into sections. (UK)

  4. TMI-2 Vessel Investigation Project integration report

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, J. R.; Rempe, J. L.; Stickler, L. A.; Korth, G. E.; Diercks, D. R.; Neimark, L. A.; Akers, D W; Schuetz, B. K.; Shearer, T L; Chavez, S. A.; Thinnes, G. L.; Witt, R. J.; Corradini, M L; Kos, J. A. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1994-03-01

    The Three Mile Island Unit 2 (TMI-2) Vessel Investigation Project (VIP) was an international effort that was sponsored by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development. The primary objectives of the VIP were to extract and examine samples from the lower head and to evaluate the potential modes of failure and the margin of structural integrity that remained in the TMI-2 reactor vessel during the accident. This report presents a summary of the major findings and conclusions that were developed from research during the VIP. Results from the various elements of the project are integrated to form a cohesive understanding of the vessel`s condition after the accident.

  5. Lung vessel segmentation in CT images using graph-cuts

    Science.gov (United States)

    Zhai, Zhiwei; Staring, Marius; Stoel, Berend C.

    2016-03-01

    Accurate lung vessel segmentation is an important operation for lung CT analysis. Filters that are based on analyzing the eigenvalues of the Hessian matrix are popular for pulmonary vessel enhancement. However, due to their low response at vessel bifurcations and vessel boundaries, extracting lung vessels by thresholding the vesselness is not sufficiently accurate. Some methods turn to graph-cuts for more accurate segmentation, as it incorporates neighbourhood information. In this work, we propose a new graph-cuts cost function combining appearance and shape, where CT intensity represents appearance and vesselness from a Hessian-based filter represents shape. Due to the amount of voxels in high resolution CT scans, the memory requirement and time consumption for building a graph structure is very high. In order to make the graph representation computationally tractable, those voxels that are considered clearly background are removed from the graph nodes, using a threshold on the vesselness map. The graph structure is then established based on the remaining voxel nodes, source/sink nodes and the neighbourhood relationship of the remaining voxels. Vessels are segmented by minimizing the energy cost function with the graph-cuts optimization framework. We optimized the parameters used in the graph-cuts cost function and evaluated the proposed method with two manually labeled sub-volumes. For independent evaluation, we used 20 CT scans of the VESSEL12 challenge. The evaluation results of the sub-volume data show that the proposed method produced a more accurate vessel segmentation compared to the previous methods, with F1 score 0.76 and 0.69. In the VESSEL12 data-set, our method obtained a competitive performance with an area under the ROC curve of 0.975, especially among the binary submissions.

  6. Latest developments in prestressed concrete vessels for gas-cooled reactors

    International Nuclear Information System (INIS)

    Ople, F.S. Jr.

    1979-01-01

    This paper is an update of the design development of prestressed concrete vessels, commonly referred to as 'PCRVs' starting with the first single-cavity PCRV for the Fort St. Vrain Nuclear Generating Station to the latest multi-cavity PCRV configurations being utilized as the primary reactor vessels for both the High Temperature Gas-Cooled Reactor (HTGR) and the Gas-Cooled Fast Breeder Reactor (GCFR) in the U.S.A. The complexity of PCRV design varies not only due to the type of vessel configuration (single versus multi-cavity) but also on the application to the specific type of reactor concept. PCRV technology as applied to the Steam Cycle HTGR is fairly well established; however, some significant technical complexities are associated with PCRV design for the Gas Turbine HTGR and the GCFR. For the Gas Turbine HTGR, for instance, the fluid dynamics of the turbo-machinery cause multi-pressure conditions to exist in various portions of the power conversion loops during operation. This condition complicates the design approach and the proof test specification for the PCRV. The geometric configuration of the multi-cavity PCRV is also more complex due to the introduction of large horizontal cylindrical cavities (housing the turbo/machines for the Gas Turbine HTGR and circulators for the GCFR) in addition to the vertical cylindrical cavities for the core and heat exchangers. Because of this complex geometry, it becomes difficult to achieve an optimum prestressing arrangement for the PCRV. Other novel features of the multi-cavity PCRV resulting from the continuing design optimization effort are the incorporation of an asymmetric (offset core) configuration and the use of large vessel cavity/penetration concrete closures directly held down by prestressing tendons for both economic and safety reasons. (orig.)

  7. Furfurol-based polymers for the sealing of reactor vessels dumped in the Arctic Kara Sea

    International Nuclear Information System (INIS)

    Heiser, J.H.; Cowgill, M.G.; Alexandrov, V.P.; Dyer, R.S.

    1997-01-01

    Between 1965 and 1988, 16 naval reactor vessels were dumped in the Arctic Kara Sea. Six of the vessels contained spent nuclear fuel that had been damaged during accidents. In addition, a container holding ∼ 60% of the damaged fuel from the No. 2 reactor of the atomic icebreaker 'Lenin' was dumped in 1967. Before dumping, the vessels were filled with a solidification agent, Conservant F, in order to prevent direct contact between the seawater and the fuel and other activated components, thereby reducing the potential for release of radionuclides into the environment. The key ingredient in Conservant F is furfurol (furfuraldehyde). Other constituents vary, depending on specific property requirements, but include epoxy resin, mineral fillers, and hardening agents. The properties of Conservant F in both its cured and uncured states are discussed, and the potential performance of the waste packages containing spent nuclear fuel in the Arctic Kara Sea is evaluated. (author)

  8. Furfurol-based polymers for the sealing of reactor vessels dumped in the Arctic Kara Sea

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, J.H.; Cowgill, M.G. [Brookhaven National Lab., Upton, NY (United States). Environmental and Waste Technology Center; Sivintsev, Yu.V. [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation); Alexandrov, V.P. [Research and Design Inst. for Power Engineering (Russian Federation); Dyer, R.S. [U.S. Environmental Protection Agency, Washington, DC (United States)

    1997-12-31

    Between 1965 and 1988, 16 naval reactor vessels were dumped in the Arctic Kara Sea. Six of the vessels contained spent nuclear fuel that had been damaged during accidents. In addition, a container holding {approx} 60% of the damaged fuel from the No. 2 reactor of the atomic icebreaker `Lenin` was dumped in 1967. Before dumping, the vessels were filled with a solidification agent, Conservant F, in order to prevent direct contact between the seawater and the fuel and other activated components, thereby reducing the potential for release of radionuclides into the environment. The key ingredient in Conservant F is furfurol (furfuraldehyde). Other constituents vary, depending on specific property requirements, but include epoxy resin, mineral fillers, and hardening agents. The properties of Conservant F in both its cured and uncured states are discussed, and the potential performance of the waste packages containing spent nuclear fuel in the Arctic Kara Sea is evaluated. (author) 4 refs.

  9. Irradiation embrittlement of reactor vessel steels

    International Nuclear Information System (INIS)

    Bros, J.

    2000-01-01

    From the historical decision of closing the Yankee Rowe NPP because of the uncertainties on the level of reactor pressure vessel neutron embrittlement, this paper reviews the technical-scientist bases of the degradation phenomena, and refers to the evolution of reactor pressure vessel radiation surveillance programs. (Author)

  10. Exponential Stabilization of an Underactuated Surface Vessel

    Directory of Open Access Journals (Sweden)

    Kristin Y. Pettersen

    1997-07-01

    Full Text Available The paper shows that a large class of underactuated vehicles cannot be asymptotically stabilized by either continuous or discontinuous state feedback. Furthermore, stabilization of an underactuated surface vessel is considered. Controllability properties of the surface vessels is presented, and a continuous periodic time-varying feedback law is proposed. It is shown that this feedback law exponentially stabilizes the surface vessel to the origin, and this is illustrated by simulations.

  11. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  12. Superior long term outcome associated with native vessel versus graft vessel PCI following secondary PCI in patients with prior CABG.

    Science.gov (United States)

    Mavroudis, Chrysostomos A; Kotecha, Tushar; Chehab, Omar; Hudson, Jonathan; Rakhit, Roby D

    2017-02-01

    Secondary percutaneous coronary intervention (PCI) in patients with prior coronary artery bypass graft surgery is increasingly common. Graft vessel PCI has higher rates of adverse events compared with native coronary vessel PCI. To investigate the clinical outcomes of patients with prior CABG who underwent secondary PCI of either a graft vessel (GV), a native coronary vessel (NV) or both graft and native (NG) vessels. 220 patients (84% male) who underwent PCI in our institution to either GV (n=89), NV (n=103) or both GV and NV (NG group) (n=28) were studied. The study population underwent 378 procedures (GV group; n=126, NV group; n=164 and NG group; n=88). Median follow up was for 36months [range 2-75months]. Target vessel revascularisation (TVR) occurred in 12.5% of the GV group and 3.6% in the NV group [p=0.0004], and was predominantly due to in-stent restenosis. Patients who had PCI due to TVR were more likely to suffer from diabetes and peripheral vascular disease. History of chronic renal failure was associated with higher risk (HR 2.21, p=0.005) whereas preserved left ventricular ejection fraction (LVEF) with lower risk (HR 0.17, p=0.0007) of death. The median survival (interval between CABG and end of follow-up period) was lower in the GV compared with the NV group (315 vs 372months p=0.005). This registry demonstrates inferior long term outcome for patients undergoing secondary PCI of GV versus NV. Where possible, a strategy of NV rather than GV target PCI should be considered in patients with prior CABG. Secondary PCI in patients with prior CABG surgery is increasingly common. Graft vessel PCI has inferior outcomes with high rates of restenosis and occlusion compared with native coronary vessel PCI. We studied the clinical outcomes of 220 patients with prior CABG who underwent secondary PCI to either a graft vessel (GV), a native coronary vessel (NV) or both graft and native (NG) vessels. Target vessel revascularisation was 5 times higher in the GV

  13. Analyzing Vessel Behavior Using Process Mining

    NARCIS (Netherlands)

    Maggi, F.M.; Mooij, A.J.; Aalst, W.M.P. van der

    2013-01-01

    In the maritime domain, electronic sensors such as AIS receivers and radars collect large amounts of data about the vessels in a certain geographical area. We investigate the use of process mining techniques for analyzing the behavior of the vessels based on these data. In the context of maritime

  14. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  15. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  16. Models and Algorithms for Container Vessel Stowage Optimization

    DEFF Research Database (Denmark)

    Delgado-Ortegon, Alberto

    .g., selection of vessels to buy that satisfy specific demands), through to operational decisions (e.g., selection of containers that optimize revenue, and stowing those containers into a vessel). This thesis addresses the question of whether it is possible to formulate stowage optimization models...... container of those to be loaded in a port should be placed in a vessel, i.e., to generate stowage plans. This thesis explores two different approaches to solve this problem, both follow a 2-phase decomposition that assigns containers to vessel sections in the first phase, i.e., master planning...

  17. Sealing analysis for nuclear vessels of PWR

    International Nuclear Information System (INIS)

    Qu Jiadi; Dou Yikang

    1988-01-01

    The fundamental equations of sealing analysis for vessels are given and a computer program named SMEC, which considers the change of stud loading, the elastic contact between flange mating surfaces and the transient thermal effects, is developed accordingly. The SMEC is verified by several test. On the basis of analysis, a new concept of classifying vessels into three types according to increasing or decreasing of bolt loading with increasing pressure is suggested. Type-A vessel is that in which the bolt loading increases monotonically with increasing pressure, while in type-B, the bolt loading decreases monotonically, and in type-C, the bolt loading changes nonmonotonically. It is important for vessel design to distinguish the types through analysis. The sealing mechanism is also discussed

  18. Method to moor an offshore operating vessel

    Energy Technology Data Exchange (ETDEWEB)

    Flory, J.F.

    1983-01-24

    A vessel such as a storage vessel is permanently moored, by means such as a yoke pivoted on the forecastle of the vessel, to a mooring leg, e.g. a riser or anchor chain, which is attached to a base located on the ocean floor. Mounted on the vessel is tension exsisting means, for example, counterweights, springs, winches, or the like, operably connected with the mooring leg for applying tension thereto such as by lifting the yoke. The top of the mooring leg is connected to the end of the yoke through a mooring swivel and a gimbaled mooring table or a universal joint. A fluid swivel may be located above the mooring table or about a load-carrying shaft connected to the mooring leg. 8 drawings.

  19. MRA of fibromuscular dysplasia in cervical vessels

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Mueller-Huelsbeck, S.; Brossmann, J.; Heller, M.

    1996-01-01

    In 386 selective angiograms of cervical vessels fibromuscular dysplasia was revealed in 4 female patients in the age of 30-54 years. FMD was located in the carotid artery (n=5) and in the vertebral artery (n=2) with a total of 8 lesions. 6/8 of the lesions of the seven cervical vessels were located typically in the mid cervical portion of the vessels and 2/6 lesions were located in the atlas loop of the vertebral artery. 4 lesions showed moderate stenosis and 4 vessels showed only mild stenosis. These patterns which demonstrated the typical morphology of fibromuscular dysplasia with alternating irregular zones of widening and narrowing were evaluated well with MR angiography, the others were missed. (orig./MG) [de

  20. Deformation of cylindrical vessel and the effect of barrel on deformation under inpulsive pressure of high explosive

    International Nuclear Information System (INIS)

    Iikura, Shoichi; Yashizawa, Hiroyasu; Sasanuma, Katsumi.

    1982-01-01

    According to the research performed so far, the result that the amount of deformation due to impulsive pressure was able to be evaluated by the impulse of impulsive pressure waves has been obtained. The analysis treating impulsive pressure waves as plane waves has been made frequently, but the analysis in which impulsive pressure waves must be treated as spherical waves, or the analysis of a vessel with a barrel (internal cylinder) is complex and difficult. In this report, the results of element test, which was carried out in the Oita Works, Asahi Chemical Industry Co., Ltd., in 1973 by the Power Reactor and Nuclear Fuel Development Corp. as the impact resistance test for fast breeder reactors, are rearranged and investigated. The specimens were the cylindrical vessels with upper and lower flanges, and 10 vessels and 9 kinds of barrels were made. Water was used as the pressure medium. The residual deformation and dynamic strain of the vessels and the wave form of pressure waves were measured. The deformation of cylindrical vessels subjected to the impulsive pressure from a point pressure source was able to be evaluated by the impulse distribution in normal direction. The maximum amount of deformation depended on the total plate thickness of barrels. (Kako, I.)

  1. Retinal Vessels Segmentation Techniques and Algorithms: A Survey

    Directory of Open Access Journals (Sweden)

    Jasem Almotiri

    2018-01-01

    Full Text Available Retinal vessels identification and localization aim to separate the different retinal vasculature structure tissues, either wide or narrow ones, from the fundus image background and other retinal anatomical structures such as optic disc, macula, and abnormal lesions. Retinal vessels identification studies are attracting more and more attention in recent years due to non-invasive fundus imaging and the crucial information contained in vasculature structure which is helpful for the detection and diagnosis of a variety of retinal pathologies included but not limited to: Diabetic Retinopathy (DR, glaucoma, hypertension, and Age-related Macular Degeneration (AMD. With the development of almost two decades, the innovative approaches applying computer-aided techniques for segmenting retinal vessels are becoming more and more crucial and coming closer to routine clinical applications. The purpose of this paper is to provide a comprehensive overview for retinal vessels segmentation techniques. Firstly, a brief introduction to retinal fundus photography and imaging modalities of retinal images is given. Then, the preprocessing operations and the state of the art methods of retinal vessels identification are introduced. Moreover, the evaluation and validation of the results of retinal vessels segmentation are discussed. Finally, an objective assessment is presented and future developments and trends are addressed for retinal vessels identification techniques.

  2. Three Dimensional Shallow Water Adaptive Hydraulics (ADH-SW3): Waterborne Vessels

    Science.gov (United States)

    2015-10-01

    Type Value Description 1 char CBOW Card type 2 int > 0 Vessel number 3 real # Ratio of vessel bow to vessel draft CSTR FRACTION OF DRAFT...APPLIED TO PSTR Field Type Value Description 1 char CSTR Card type 2 int > 0 Vessel number 3 real # Ratio of vessel stern to vessel draft PROP

  3. Roi Detection and Vessel Segmentation in Retinal Image

    Science.gov (United States)

    Sabaz, F.; Atila, U.

    2017-11-01

    Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  4. Power reactor pressure vessel benchmarks

    International Nuclear Information System (INIS)

    Rahn, F.J.

    1978-01-01

    A review is given of the current status of experimental and calculational benchmarks for use in understanding the radiation embrittlement effects in the pressure vessels of operating light water power reactors. The requirements of such benchmarks for application to pressure vessel dosimetry are stated. Recent developments in active and passive neutron detectors sensitive in the ranges of importance to embrittlement studies are summarized and recommendations for improvements in the benchmark are made. (author)

  5. Commissioning result of the KSTAR in-vessel cryo-pump

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y. B.; Lee, H. J.; Park, Y.M. [National Fusion Research Institute, Daejeon (Korea, Republic of); and others

    2013-12-15

    KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to LN2 one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

  6. Design and thermal/hydraulic characteristics of the ITER-FEAT vacuum vessel

    International Nuclear Information System (INIS)

    Onozuka, M.; Ioki, K.; Sannazzaro, G.; Utin, Y.; Yoshimura, H.

    2001-01-01

    Recent progress in structural design and thermal and hydraulic assessment of the vacuum vessel (VV) for ITER-FEAT is presented. Because of the direct attachment of the blanket modules to the VV, the module support structures are recessed into the double-wall VV, partially replacing the stiffening ribs between the VV shells to simplify the VV structure. Structural integrity of the VV is provided by the ribs and the module support structures with local reinforcement ribs. The detailed structural design of the VV taking account of the fabricability and code/standard acceptance is presented. Cost reduction of the VV fabrication using casting or forging is proposed. A high heat removal capability is required for the VV cooling to keep the thermal stress below the allowable. It is expected that natural thermo-gravitational convection due to the heat flux from the vessel wall to the water will enhance heat transfer characteristics even in the low flow velocity region

  7. Design and thermal/hydraulic characteristics of the ITER-FEAT vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M. E-mail: onozukm@itereu.de; Ioki, K.; Sannazzaro, G.; Utin, Y.; Yoshimura, H

    2001-11-01

    Recent progress in structural design and thermal and hydraulic assessment of the vacuum vessel (VV) for ITER-FEAT is presented. Because of the direct attachment of the blanket modules to the VV, the module support structures are recessed into the double-wall VV, partially replacing the stiffening ribs between the VV shells to simplify the VV structure. Structural integrity of the VV is provided by the ribs and the module support structures with local reinforcement ribs. The detailed structural design of the VV taking account of the fabricability and code/standard acceptance is presented. Cost reduction of the VV fabrication using casting or forging is proposed. A high heat removal capability is required for the VV cooling to keep the thermal stress below the allowable. It is expected that natural thermo-gravitational convection due to the heat flux from the vessel wall to the water will enhance heat transfer characteristics even in the low flow velocity region.

  8. Low cycle fatigue behavior of a ferritic reactor pressure vessel steel

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, Apu, E-mail: asarkar@barc.gov.in; Kumawat, Bhupendra K.; Chakravartty, J.K.

    2015-07-15

    The cyclic stress–strain response and the low cycle fatigue (LCF) behavior of 20MnMoNi55 pressure vessel steel were studied. Tensile strength and LCF properties were examined at room temperature (RT) using specimens cut from rolling direction of a rolled block. The fully reversed strain-controlled LCF tests were conducted at a constant total strain rate with different axial strain amplitude levels. The cyclic strain–stress relationships and the strain–life relationships were obtained through the test results, and related LCF parameters of the steel were calculated. The studied steel exhibits cyclic softening behavior. Furthermore, analysis of stabilized hysteresis loops showed that the steel exhibits non-Masing behavior. Complementary scanning electron microscopy examinations were also carried out on fracture surfaces to reveal dominant damage mechanisms during crack initiation, propagation and fracture. Multiple crack initiation sites were observed on the fracture surface. The investigated LCF behavior can provide reference for pressure vessel life assessment and fracture mechanisms analysis.

  9. Elastic-plastic fracture mechanics for nuclear pressure vessels: a preliminary appraisal

    International Nuclear Information System (INIS)

    Hahn, G.T.; Broek, D.; Marschall, C.W.; Rosenfield, A.R.; Rybicki, E.F.; Schmueser, D.W.; Stonesifer, R.B.; Kanninen, M.F.

    1978-01-01

    A research program directed at assessing the margin of safety of flawed nuclear pressure vessels near and beyond general yielding is described. The program has the general objective of developing an elastic-plastic fracture mechanics methodology. The approach is based on the use of finite element models together with experimental results to identify criteria appropriate for the onset of crack extension and for stable crack growth. A number of criteria beyond the conventional LEFM R curve are being evaluated. These include the critical values of the J-integral, its derivative, the crack tip opening angle, the average crack opening angle, a generalized energy release rate, its components and a crack tip force. The optimum fracture criterion for nuclear vessels is being determined by systematic measurements of load extension curves, strain distribution, crack opening displacement, stable crack growth and instability on 'toughness scaled' model materials. Computations have been performed for center cracked panels of a model material (2219-T87 aluminium) for full shear failure. (author)

  10. Vessel eddy current characteristics in SST-1 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jana, Subrata; Pradhan, Subrata, E-mail: pradhan@ipr.res.in; Dhongde, Jasraj; Masand, Harish

    2016-11-15

    Highlights: • Eddy current distribution in the SST-1 vacuum vessel. • Circuit model analysis of eddy current. • A comparison of the field lines with and without the plasma column in identical conditions. • The influence of eddy current in magnetic NULL dynamics. - Abstract: Eddy current distribution in the vacuum vessel of the Steady state superconducting (SST-1) tokamak has been determined from the experimental data obtained using an array of internal voltage loops (flux loop) installed inside the vacuum vessel. A simple circuit model has been employed. The model takes into account the geometric and constructional features of SST-1 vacuum vessel. SST-1 vacuum vessel is a modified ‘D’ shaped vessel having major axis of 1.285 m and minor axis of 0.81 m and has been manufactured from non-magnetic stainless steel. The Plasma facing components installed inside the vacuum vessel are graphite blocks mounted on Copper Chromium Zirconium (CuCrZr) heat sink plates on inconel supports. During discharge of the central solenoid, eddy currents get generated in the vacuum vessel and passive supports on it. These eddy currents influence the early magnetic NULL dynamics and plasma break-down and start-up characteristics. The computed results obtained from the model have been benchmarked against experimental data obtained in large number of SST-1 plasma shots. The results are in good agreement. Once bench marked, the calculated eddy current based on flux loop signal and circuit equation model has been extended to the reconstruction of the overall B- field contours of SST-1 tokamak in the vessel region. A comparison of the field lines with and without the plasma column in identical conditions of the central solenoid and equilibrium field profiles has also been done with an aim to quantify the diagnostics responses in vacuum shots.

  11. Foundamental characteristics of layered pressure vessel

    International Nuclear Information System (INIS)

    Moriwaki, Yoshikazu; Fugino, Masayuki; Shimizu, Yasuhiro; Nakamura, Takeshi

    1978-01-01

    Pressure vessels become larger and the working pressure become higher with the remarkable development of petroleum, chemical, thermal power generation and atomic energy industries. Multi-layered pressure vessels can be manufactured cheaply without large installations, and large wall thickness can be made, therefore they are suitable for large pressure vessels. The stress and deformation behaviors of such vessels are very complex because of the effect of frictional force working between layers. In this study, the phenomena arising in multiple layers and the difference as compared with single wall were studied fundamentally as one step for analyzing multi-layered pressure vessels as a whole. Finite element technique was employed as the analyzing method, and the behavior of multiple layers was analyzed, regarding it as multiple contact problem. The behavior of multiple layers seems to appear conspicuously in case of bending load, therefore the basic characteristics regarding bending were examined. The evaluation of interfacial stiffness was carried out by experiment. The computer program for analyzing multiple contact problem was developed. In order to examine the validity of the program, comparison with the analytical solution heretofore and the result of calculation by finite element technique was carried out. Moreover, the experimental proof with multi-layered models was made. The frictional force between layers hardly contributes to the stiffness. (Kako, I.)

  12. 46 CFR 115.812 - Pressure vessels and boilers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vessels and boilers. 115.812 Section 115.812... CERTIFICATION Material Inspections § 115.812 Pressure vessels and boilers. (a) Pressure vessels must be tested... testing requirements for boilers are contained in § 61.05 in subchapter F of this chapter. [CGD 85-080, 61...

  13. Does bipolar electrocoagulation time affect vessel weld strength?

    Science.gov (United States)

    Harrison, J D; Morris, D L

    1991-01-01

    The value of the bipolar electrocoagulator in the haemostasis of bleeding ulcers is controversial. We have therefore investigated the effect of different coagulation times on vessel weld strength achieved by the bipolar device. Welds were then made in vessels of known diameter using a standard 10F endoscopic haemostatic probe at coagulation times of two and 20 seconds. The intravascular temperature achieved at each time was measured. Vessel weld strength achieved by bipolar electrocoagulation was much greater at 20 seconds (approximately twice that at two seconds) and was highly significantly greater at all vessel diameters. There was a gradual reduction in weld strength with increasing vessel diameter, an effect that was seen for both two and 20 seconds of electrocoagulation. Intravascular temperature was significantly higher at 20 seconds than at two seconds. We conclude that vessel weld strength is related to coagulation time and that any future studies comparing the bipolar electrocoagulator with other haemostatic devices should use longer periods of bipolar electrocoagulation and record the coagulation time in order to optimise the clinical value of the device. PMID:1864540

  14. An interior vessel viewing system for DIII-D

    International Nuclear Information System (INIS)

    Senior, R.

    1989-11-01

    It was anticipated that there could be damage to the interior walls of the vacuum vessel during operations of the DIII-D tokamak. A method of viewing the inside of the vessel from the outside was required, that would allow the interior walls to be inspected visually for damage and to locate any debris resulting from operations. A miniature closed circuit television color camera system was developed which could be inserted into one of several ports of the vessel during a 'clean' vent, i.e., vented to inert gas. The system has pan, tilt and zoom capability and carries its own lighting. The use of this system allows a quick assessment of the condition of the vessel to be made under 'clean' vent conditions. This precludes the need for the permit process and manned entry into the vessel which would allow air inside the vessel. A permanent record of the inspection can then be made on video tape. The design and configuration of this camera system is presented and its use as a diagnostic tool discussed. 2 refs., 5 figs

  15. Integrity of PWR pressure vessels during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Iskander, S.K.; Whitman, G.D.

    1982-01-01

    The reactor pressure vessel in a pressurized water reactor is normally subjected to temperatures and pressures that preclude propagation of sharp, crack-like defects that might exist in the wall of the vessel. However, there is a class of postulated accidents, referred to as overcooling accidents, that can subject the pressure vessel to severe thermal shock while the pressure is substantial. As a result of such accidents vessels containing high concentrations of copper and nickel, which enhance radiation embrittlement, may possess a potential for extensive propagation of preexistent inner surface flaws prior to the vessel's normal end of life. For the purpose of evaluating this problem a state-of-the-art fracture mechanics model was developed and has been used for conducting parametric analyses and for calculating several recorded PWR transients. Results of the latter analysis indicate that there may be some vessels that have a potential for failure today if subjected to a Rancho Seco (1978) or TMI-2 (1979) type transient. However, the calculational model may be excessively conservative, and this possibility is under investigation

  16. Integrity of PWR pressure vessels during overcooling accidents

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Iskander, S.K.; Whitman, G.D.

    1982-01-01

    The reactor pressure vessel in a pressurized water reactor is normally subjected to temperatures and pressures that preclude propagation of sharp, crack-like defects that might exist in the wall of the vessel. However, there is a class of postulated accidents, referred to as overcooling accidents, that can subject the pressure vessel to severe thermal shock while the pressure is substantial. As a result of such accidents, vessels containing high concentrations of copper and nickel, which enhance radiation embrittlement, may possess a potential for extensive propagation of preexistent inner surface flaws prior to the vessel's normal end of life. A state-of-the-art fracture-mechanics model was developed and has been used for conducting parametric analyses and for calculating several recorded PWR transients. Results of the latter analysis indicate that there may be some vessels that have a potential for failure in a few years if subjected to a Rancho Seco-type transient. However, the calculational model may be excessively conservative, and this possibility is under investigation

  17. Impact of chemistry on Standard High Solids Vessel Design mixing

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-02

    The plan for resolving technical issues regarding mixing performance within vessels of the Hanford Waste Treatment Plant Pretreatment Facility directs a chemical impact study to be performed. The vessels involved are those that will process higher (e.g., 5 wt % or more) concentrations of solids. The mixing equipment design for these vessels includes both pulse jet mixers (PJM) and air spargers. This study assesses the impact of feed chemistry on the effectiveness of PJM mixing in the Standard High Solids Vessel Design (SHSVD). The overall purpose of this study is to complement the Properties that Matter document in helping to establish an acceptable physical simulant for full-scale testing. The specific objectives for this study are (1) to identify the relevant properties and behavior of the in-process tank waste that control the performance of the system being tested, (2) to assess the solubility limits of key components that are likely to precipitate or crystallize due to PJM and sparger interaction with the waste feeds, (3) to evaluate the impact of waste chemistry on rheology and agglomeration, (4) to assess the impact of temperature on rheology and agglomeration, (5) to assess the impact of organic compounds on PJM mixing, and (6) to provide the technical basis for using a physical-rheological simulant rather than a physical-rheological-chemical simulant for full-scale vessel testing. Among the conclusions reached are the following: The primary impact of precipitation or crystallization of salts due to interactions between PJMs or spargers and waste feeds is to increase the insoluble solids concentration in the slurries, which will increase the slurry yield stress. Slurry yield stress is a function of pH, ionic strength, insoluble solids concentration, and particle size. Ionic strength and chemical composition can affect particle size. Changes in temperature can affect SHSVD mixing through its effect on properties such as viscosity, yield stress, solubility

  18. Depressurization as a means of leak checking large vacuum vessels

    International Nuclear Information System (INIS)

    Callis, R.W.; Langhorn, A.; Petersen, P.I.; Ward, C.; Wesley, J.

    1985-01-01

    A common problem associated with large vacuum vessels used in magnetic confinement fusion experiments is that leak checking is hampered by the inaccessibility to most of the vacuum vessel surface. This inaccessibility is caused by the close proximity of magnetic coils, diagnostics and, for those vessels that are baked, the need to completely surround the vessel with a thermal insulation blanket. These obstructions reduce the effectiveness of the standard leak checking method of using a mass spectrometer and spraying a search gas such as helium on the vessel exterior. Even when the presence of helium is detected, its entry point into the vessel cannot always be pinpointed. This paper will describe a method of overcoming this problem. By slightly depressurizing the vessel, an influx of helium through the leak is created. The leak site can then be identified by personnel within the vessel using standard sniffing procedures. There are two conditions which make this method of leak checking practical. First, the vessel need only be depressurized 2 psi, thus allowing personnel inside to perform the sniffing operation. Second, the sniffing probe used (Leybold--Heraus ''Quick Test'') could detect a change in helium concentration as small as 100 ppb, which allows for faster scanning of the vessel inferior. Use of this technique to find an elusive 10 -3 Torrxl/s leak in the Doublet III tokamak vacuum vessel will be presented

  19. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. 46 CFR 111.105-35 - Vessels carrying coal.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying coal. 111.105-35 Section 111.105-35...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-35 Vessels carrying coal. (a) The following are Class II, Division 1, (Zone 10 or Z) locations on a vessel that carries coal: (1) The interior of each coal...

  1. Vessel Sewage Discharges

    Science.gov (United States)

    Vessel sewage discharges are regulated under Section 312 of the Clean Water Act, which is jointly implemented by the EPA and Coast Guard. This homepage links to information on marine sanitation devices and no discharge zones.

  2. Apparative developments for inservice inspections of reactor pressure vessels

    International Nuclear Information System (INIS)

    Bohn, H.; Ruthrof, K.; Barbian, O.A.; Kappes, W.; Neumann, R.; Stanger, H.K.

    1987-01-01

    Emphasizing PWR pressure vessel (RPV) inspections, recent developments of new generations of automated and mechanized ultrasonic inspection equipment are presented. Starting from general equipment design and inservice implenentation criteria, specific examples are given. Main attention is directed to equipment realization of phased array and ALOK inspection techniques, especially in their combination. Refined aspects of subsequent computer processing and evaluation of defect detection data are described. Analytical features and potential for further developments become evident. Remote controlled RPV inspections are stressed by describing a new generation of central mast manipulators, forming an integral part of total inservice inspection system. (orig./HP)

  3. The JET high temperature in-vessel inspection system

    International Nuclear Information System (INIS)

    Businaro, T.; Cusack, R.; Calbiati, L.; Raimondi, T.

    1989-01-01

    The JET In-vessel Inspection System (IVIS) has been enhanced for operation under the following nominal conditions: vacuum vessel at 350 degC; vacuum vessel evacuated (∼10 -9 mbar); radiation dose during D-T phase 10 rads. The target resolution of the pictures is 2 mm at 5 m distance and tests on radiation resistance of the IVIS system are being carried out. Since June 1988, the new system is installed in the JET machine and the first inspections of the intire vessel at 250 degC have been satisfactory done. (author). 3 refs.; 6 figs.; 1 tab

  4. Investigation of vessel visibility of iterative reconstruction method in coronary computed tomography angiography using simulated vessel phantom

    International Nuclear Information System (INIS)

    Inoue, Takeshi; Uto, Fumiaki; Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Hoshino, Takashi; Miura, Youhei; Terakawa, Syouichi

    2012-01-01

    Iterative reconstruction methods can reduce the noise of computed tomography (CT) images, which are expected to contribute to the reduction of patient dose CT examinations. The purpose of this study was to investigate impact of an iterative reconstruction method (iDose 4 , Philips Healthcare) on vessel visibility in coronary CT angiography (CTA) by using phantom studies. A simulated phantom was scanned by a CT system (iCT, Philips Healthcare), and the axial images were reconstructed by filtered back projection (FBP) and given a level of 1 to 7 (L1-L7) of the iterative reconstruction (IR). The vessel visibility was evaluated by a quantitative analysis using profiles across a 1.5-mm diameter simulated vessel as well as visual evaluation for multi planar reformation (MPR) images and volume rendering (VR) images in terms of the normalized-rank method with analysis of variance. The peak CT value of the profiles decreased with IR level and full width at half maximum of the profile also decreased with the IR level. For normalized-rank method, there was no statistical difference between FBP and L1 (20% dose reduction) for both MPR and VR images. The IR levels higher than L1 sacrificed the spatial resolution for the 1.5-mm simulated vessel, and their visual vessel visibilities were significantly inferior to that of the FBP. (author)

  5. Apparatus for carrying out ultrasonic inspection of pressure vessels

    International Nuclear Information System (INIS)

    Dent, K.H.; Greenhalgh, F.G.

    1975-01-01

    An apparatus is described for moving an ultrasonic scanning mechanism over the interior surface of a pressure vessel and comprising a mast for supporting the scanning mechanism inside the vessel and a carriage for traversing the mast within the vessel, the mast being pivotably secured to the carriage so that when the ultrasonic scanning mechanism contacts the interior surface of the pressure vessel the mast is caused to pivot. (auth)

  6. High-resolution vessel wall MRI for the evaluation of intracranial atherosclerotic disease

    Energy Technology Data Exchange (ETDEWEB)

    De Havenon, Adam [University of Utah, Department of Neurology, Salt Lake City, UT (United States); Mossa-Basha, Mahmud [University of Washington, Department of Radiology, Seattle, WA (United States); Shah, Lubdha; Kim, Seong-Eun; Parker, Dennis; McNally, J.S. [University of Utah, Department of Radiology, Salt Lake City, UT (United States); Park, Min [University of Utah, Department of Neurosurgery, Salt Lake City, UT (United States)

    2017-12-15

    High-resolution vessel wall MRI (vwMRI) of the intracranial arteries is an emerging diagnostic imaging technique with the goal of evaluating vascular pathology. vwMRI sequences have high spatial resolution and directly image the vessel wall by suppressing blood signal. With vwMRI, it is possible to identify distinct morphologic and enhancement patterns of atherosclerosis that can provide important information about stroke etiology and recurrence risk. We present a review of vwMRI research in relation to intracranial atherosclerosis, with a focus on the relationship between ischemic stroke and atherosclerotic plaque T1 post-contrast enhancement or plaque/vessel wall morphology. The goal of this review is to provide readers with the most current understanding of the reliability, incidence, and importance of specific vwMRI findings in intracranial atherosclerosis, to guide their interpretation of vwMRI research, and help inform clinical interpretation of vwMRI. We will also provide a translational perspective on the existing vwMRI literature and insight into future vwMRI research questions and objectives. With increased use of high field strength MRI, powerful gradients, and improved pulse sequences, vwMRI will become standard-of-care in the diagnosis and prognosis of patients with cerebrovascular disease, making a firm grasp of its strengths and weakness important for neuroimagers. (orig.)

  7. High-resolution vessel wall MRI for the evaluation of intracranial atherosclerotic disease

    International Nuclear Information System (INIS)

    De Havenon, Adam; Mossa-Basha, Mahmud; Shah, Lubdha; Kim, Seong-Eun; Parker, Dennis; McNally, J.S.; Park, Min

    2017-01-01

    High-resolution vessel wall MRI (vwMRI) of the intracranial arteries is an emerging diagnostic imaging technique with the goal of evaluating vascular pathology. vwMRI sequences have high spatial resolution and directly image the vessel wall by suppressing blood signal. With vwMRI, it is possible to identify distinct morphologic and enhancement patterns of atherosclerosis that can provide important information about stroke etiology and recurrence risk. We present a review of vwMRI research in relation to intracranial atherosclerosis, with a focus on the relationship between ischemic stroke and atherosclerotic plaque T1 post-contrast enhancement or plaque/vessel wall morphology. The goal of this review is to provide readers with the most current understanding of the reliability, incidence, and importance of specific vwMRI findings in intracranial atherosclerosis, to guide their interpretation of vwMRI research, and help inform clinical interpretation of vwMRI. We will also provide a translational perspective on the existing vwMRI literature and insight into future vwMRI research questions and objectives. With increased use of high field strength MRI, powerful gradients, and improved pulse sequences, vwMRI will become standard-of-care in the diagnosis and prognosis of patients with cerebrovascular disease, making a firm grasp of its strengths and weakness important for neuroimagers. (orig.)

  8. Advanced in-vessel retention design for next generation risk management

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kune Y; Hwang, Il Soon [Seoul National University, Seoul (Korea, Republic of)

    1998-12-31

    In the TMI-2 accident, approximately twenty (20) tons of molten core material drained into the lower plenum. Early advanced light water reactor (LWR) designs assumed a lower head failure and incorporated various measures for ex-vessel accident mitigation. However,one of the major findings from the TMI-2 Vessel Investigation Project was that one part of the reactor lower head wall estimated to have attained a temperature of 1100 deg C for about 30 minutes has seemingly experienced a comparatively rapid cooldown with no major threat to the vessel integrity. In this regard, recent empirical and analytical studies have shifted interests to such in-vessel retention designs or strategies as reactor cavity flooding, in-vessel flooding and engineered gap cooling of the vessel. Accurate thermohydrodynamic and creep deformation modeling and rupture prediction are the key to the success in developing practically useful in-vessel accident/risk management strategies. As an advanced in-vessel design concept, this work presents the COrium Attack Syndrome Immunization Structures (COASIS) that are being developed as prospective in-vessel retention devices for a next-generation LWR in concert with existing ex-vessel management measures. Both the engineered gap structures in-vessel (COASISI) and ex-vessel (COASISO) are demonstrated to maintain effective heat transfer geometry during molten core debris attack when applied to the Korean Standard Nuclear Power Plant (KSNPP) reactor. The likelihood of lower head creep rupture during a severe accident is found to be significantly suppressed by the COASIS options. 15 refs., 5 figs., 1 tab. (Author)

  9. Advanced in-vessel retention design for next generation risk management

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kune Y.; Hwang, Il Soon [Seoul National University, Seoul (Korea, Republic of)

    1997-12-31

    In the TMI-2 accident, approximately twenty (20) tons of molten core material drained into the lower plenum. Early advanced light water reactor (LWR) designs assumed a lower head failure and incorporated various measures for ex-vessel accident mitigation. However,one of the major findings from the TMI-2 Vessel Investigation Project was that one part of the reactor lower head wall estimated to have attained a temperature of 1100 deg C for about 30 minutes has seemingly experienced a comparatively rapid cooldown with no major threat to the vessel integrity. In this regard, recent empirical and analytical studies have shifted interests to such in-vessel retention designs or strategies as reactor cavity flooding, in-vessel flooding and engineered gap cooling of the vessel. Accurate thermohydrodynamic and creep deformation modeling and rupture prediction are the key to the success in developing practically useful in-vessel accident/risk management strategies. As an advanced in-vessel design concept, this work presents the COrium Attack Syndrome Immunization Structures (COASIS) that are being developed as prospective in-vessel retention devices for a next-generation LWR in concert with existing ex-vessel management measures. Both the engineered gap structures in-vessel (COASISI) and ex-vessel (COASISO) are demonstrated to maintain effective heat transfer geometry during molten core debris attack when applied to the Korean Standard Nuclear Power Plant (KSNPP) reactor. The likelihood of lower head creep rupture during a severe accident is found to be significantly suppressed by the COASIS options. 15 refs., 5 figs., 1 tab. (Author)

  10. Evaluation of In-Vessel Corium Retention under a Severe Accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Rae-Joon; Kang, Kyung-Ho; Ha, Kwang-Soon; Kim, Jong-Tae; Koo, Kil-Mo; Cho, Young-Ro; Hong, Seong-Wan; Kim, Sang-Baik; Kim, Hee-Dong

    2008-02-15

    The current study on In-Vessel corium Retention and its application activities to the actual nuclear power plant have been reviewed and discussed in this study. Severe accident sequence which determines an initial condition of the IVR has been evaluated and late phase melt progression, heat transfer on the outer reactor vessel, and in-vessel corium cooling mechanism have been estimated in detail. During the high pressure sequence of the reactor coolant system, a natural circulation flow of the hot steam leads to a failure of the pressurizer surge line before the reactor vessel failure, which leads to a rapid decrease of the reactor coolant system pressure. The results of RASPLAV/MASCA study by OECD/NEA have shown that a melt stratification has occurred in the lower plenum of the reactor vessel. In particular, laver inversion has occurred, which is that a high density of the metal melt moves to the lower part of the oxidic melt layer. A method of heat transfer enhancement on the outer reactor vessel is an optimal design of the reactor vessel insulation for an increase of the natural circulation flow between the outer reactor vessel and the its insulation, and an increase of the critical Heat flux on the outer reactor vessel by using various method, such as Nono fluid, coated reactor vessel, and so on. An increase method of the in-vessel melt cooling is a development of the In-vessel core catcher and a decrease of focusing effect in the metal layer.

  11. ROI DETECTION AND VESSEL SEGMENTATION IN RETINAL IMAGE

    Directory of Open Access Journals (Sweden)

    F. Sabaz

    2017-11-01

    Full Text Available Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  12. Emergency venting of pressure vessels

    International Nuclear Information System (INIS)

    Steinkamp, H.

    1995-01-01

    With the numerical codes developed for safety analysis the venting of steam vessel can be simulated. ATHLET especially is able to predict the void fraction depending on the vessel height. Although these codes contain a one-dimensional model they allow the description of complex geometries due to the detailed nodalization of the considered apparatus. In chemical reactors, however, the venting process is not only influenced by the flashing behaviour but additionally by the running chemical reaction in the vessel. Therefore the codes used for modelling have to consider the kinetics of the chemical reaction. Further multi-component systems and dissolving processes have to be regarded. In order to preduct the fluid- and thermodynamic process it could be helpful to use 3-dimensional codes in combination with the one-dimensional codes as used in nuclear industry to get a more detailed describtion of the running processes. (orig./HP)

  13. Confinement Vessel Assay System: Design and Implementation Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Gomez, Cipriano D.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC and A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using 252 Cf placed a various locations throughout the measurement system. Measurements were also performed with a 252 Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

  14. Ultrasonographic Examination of Some Vessels in Dogs and the Characteristics of Blood Flow in These Vessels

    Directory of Open Access Journals (Sweden)

    Figurová M.

    2017-12-01

    Full Text Available The examination by Doppler ultrasonography provides haemodynamic information about blood flow velocity in a respective vessel. It specifies high- and lowresistance flow patterns. The aim of our study was to record the flow in a. carotis communis, a. femoralis and aa. renales in 16 adult clinically healthy dogs of small and medium size; characterize the types of vessels and also determine the pulsatility index (PI and the resistive index (RI of these vessels. The a. femoralis is a high-resistance vessel with a pronounced three-peak waveform. The aa. renales gives a typical picture of a low-resistance flow pattern. The characteristics of a. carotis communis involves different images of its branches a. carotis interna and a. carotis externa. In the investigated groups we observed a medium degree of pulsatility (atypical highresistance flow pattern with an absence of reverse flow. The mean measured values of indices for a. carotis communis were: left side PI 1.824 and RI 0.742; right side PI 1.891 and RI 0.746, and for aa. renales: PI 1.366 ± 0.04 and RI 0.684 ± 0.05.

  15. [Large vessels vasculopathy in systemic sclerosis].

    Science.gov (United States)

    Tejera Segura, Beatriz; Ferraz-Amaro, Iván

    2015-12-07

    Vasculopathy in systemic sclerosis is a severe, in many cases irreversible, manifestation that can lead to amputation. While the classical clinical manifestations of the disease have to do with the involvement of microcirculation, proximal vessels of upper and lower limbs can also be affected. This involvement of large vessels may be related to systemic sclerosis, vasculitis or atherosclerotic, and the differential diagnosis is not easy. To conduct a proper and early diagnosis, it is essential to start prompt appropriate treatment. In this review, we examine the involvement of large vessels in scleroderma, an understudied manifestation with important prognostic and therapeutic implications. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  16. Reactor vessel using metal oxide ceramic membranes

    Science.gov (United States)

    Anderson, Marc A.; Zeltner, Walter A.

    1992-08-11

    A reaction vessel for use in photoelectrochemical reactions includes as its reactive surface a metal oxide porous ceramic membrane of a catalytic metal such as titanium. The reaction vessel includes a light source and a counter electrode. A provision for applying an electrical bias between the membrane and the counter electrode permits the Fermi levels of potential reaction to be favored so that certain reactions may be favored in the vessel. The electrical biasing is also useful for the cleaning of the catalytic membrane.

  17. In-service inspection robot for PFBR main vessel- concept

    Energy Technology Data Exchange (ETDEWEB)

    Rajendran, S; Ramakumar, M S [Bhabha Atomic Research Centre, Mumbai (India). Div. of Remote Handling and Robotics

    1994-12-31

    In-service inspection (ISI) of critical components in a nuclear reactor is one of the foremost and important tasks which reveals the state of health of the system, thereby ensuring the safety of the plant, personnel and environment. Prototype Fast Breeder Reactor (PFBR) is designed as a pool type reactor. A safety vessel is provided in the design which envelopes the main reactor vessel. The ISI of the main vessel is mandatory and will be carried out by a robot which will operate on this annular gap. The design of the robot is such that it can crawl around the vessel and into the gap at the bottom of the vessel relying on friction grip. The mobile robot will carry a CCTV camera and the inspection technique packages into the interspace, position and orient these to carry out the ISI of the main vessel. The paper discusses about the design features of the robot including the gripping mechanism and the crawling sequence to perform ISI of the reactor vessel. 3 figs.

  18. In-service inspection robot for PFBR main vessel- concept

    International Nuclear Information System (INIS)

    Rajendran, S.; Ramakumar, M.S.

    1994-01-01

    In-service inspection (ISI) of critical components in a nuclear reactor is one of the foremost and important tasks which reveals the state of health of the system, thereby ensuring the safety of the plant, personnel and environment. Prototype Fast Breeder Reactor (PFBR) is designed as a pool type reactor. A safety vessel is provided in the design which envelopes the main reactor vessel. The ISI of the main vessel is mandatory and will be carried out by a robot which will operate on this annular gap. The design of the robot is such that it can crawl around the vessel and into the gap at the bottom of the vessel relying on friction grip. The mobile robot will carry a CCTV camera and the inspection technique packages into the interspace, position and orient these to carry out the ISI of the main vessel. The paper discusses about the design features of the robot including the gripping mechanism and the crawling sequence to perform ISI of the reactor vessel. 3 figs

  19. Distribution of the In-Vessel Diagnostics in ITER Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    González, Jorge, E-mail: Jorge.Gonzalez@iter.org [Rüecker Lypsa, Carretera del Prat, 65, Cornellá de Llobregat (Spain); Clough, Matthew; Martin, Alex; Woods, Nick; Suarez, Alejandro [ITER Organization, Route de Vinon sur Verdon-CS 90 046 13067 Saint Paul Lez Durance (France); Martinez, Gonzalo [Technical University Of Catalonia (UPC), Barcelona-Tech, Barcelona (Spain); Stefan, Gicquel; Yunxing, Ma [ITER Organization, Route de Vinon sur Verdon-CS 90 046 13067 Saint Paul Lez Durance (France)

    2017-01-15

    The ITER In-Vessel Diagnostics have been distributed around the In-Vessel shell to understand burning plasma physics and assist in machine operation. Each diagnostics component has its own requirements, constraints, and even exclusion among them for the highly complex In-Vessel environment. The size of the plasma, the requirement to be able to align the blanket system to the magnetic centre of the machine, the cooling requirements of the blanket system and the size of the pressure vessel itself all add to the difficulties of integrating these systems into the remaining space available. The available space for the cables inside the special trays (in-Vessel looms) is another constraint to allocate In-Vessel electrical sensors. Besides this, there are issues with the Assembly sequences and surface & volumetric neutron heating considerations that have imposed several additional restrictions.

  20. Predicting Vessel Trajectories from Ais Data Using R

    Science.gov (United States)

    2017-06-01

    Source: Hampton (2009). A vessel operator with AIS is able to get useful information about the other vessels in the area by selecting a vessel icon ...random forest model on our computer. All calculations are done on a MacBook-Pro with 2.7GHz quad-core Intel Core i7, and 16GB of memory . H2O allows us

  1. Inspection apparatus for a vessel made of magnetic metal

    International Nuclear Information System (INIS)

    Clark, J.P.; Foster, A.C.; Smith, T.D.

    1976-01-01

    Previous systems intended for in-situ inspection of the pressure vessels of nuclear reactors are of uneasy use on encumbered surfaces. Said invention relates to a remote-control device for inspecting vessel walls. It comprises a conveyor able to be propelled, possibly around obstacles, towards any place inside the vessel; said vehicle is provided with magnetic wheels driven by an electric motor and separately controlled. The conveyor is accurately located on the vessel by using an acoustic device involving a triangular method, and consisting in an acoustic signal emitter mounted on the conveyor and at least three receiving transducers mounted on the vessel wall [fr

  2. The Direct Effect of Flexible Walls on Fontan Connection Fluid Dynamics

    Science.gov (United States)

    Tree, Mike; Fagan, Kiley; Yoganathan, Ajit

    2014-11-01

    The current standard treatment for sufferers of congenital heart defects is the palliative Fontan procedure. The Fontan procedure results in an anastomosis of major veins directly to the branched pulmonary arteries bypassing the dysfunctional ventricle. This total cavopulmonary connection (TCPC) extends life past birth, but Fontan patients still suffer long-term complications like decreased exercise capacity, protein-losing enteropathy, and pulmonary arteriovenous malformations (PAVM). These complications have direct ties to fluid dynamics within the connection. Previous experimental and computation studies of Fontan connection fluid dynamics employed rigid vessel models. More recent studies utilize flexible models, but a direct comparison of the fundamental fluid dynamics between rigid and flexible vessels only exists for a computational model, without a direct experimental validation. Thus, this study was a direct comparison of fluid dynamics within a rigid and two compliant idealized TCPCs. 2D particle image velocimetry measurements were collected at the connection center plane. Results include power loss, hepatic flow distribution, fluid shear stress, and flow structure recognition. The effect of flexible walls on these values and clinical impact will be discussed.

  3. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hoon; Chang, Soon Heung; Kim, Soo Hyung; Kim, Kee Poong; Lee, Hyoung Wook; Jang, Kwang Keol; Jeong, Yong Hoon; Kim, Sang Jin; Lee, Seong Jin [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Park, Jae Hong [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    2001-03-15

    In this work, assessment system for methodology for reactor pressure vessel integrity is developed. Assessment system is make up of severe accident assessment code which can calculate the conditions of plant and structural analysis code which can assess the integrity of reactor vessel using given plant conditions. An assessment of cavity flooding using containment spray system has been done. As a result, by the containment spray, cavity can be flooded successfully and CCI can be reduced. The technical backgrounds for external vessel cooling and corium cooling on the cavity are summarized and provided in this report.

  4. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    International Nuclear Information System (INIS)

    Huh, Hoon; Chang, Soon Heung; Kim, Soo Hyung; Kim, Kee Poong; Lee, Hyoung Wook; Jang, Kwang Keol; Jeong, Yong Hoon; Kim, Sang Jin; Lee, Seong Jin; Park, Jae Hong

    2001-03-01

    In this work, assessment system for methodology for reactor pressure vessel integrity is developed. Assessment system is make up of severe accident assessment code which can calculate the conditions of plant and structural analysis code which can assess the integrity of reactor vessel using given plant conditions. An assessment of cavity flooding using containment spray system has been done. As a result, by the containment spray, cavity can be flooded successfully and CCI can be reduced. The technical backgrounds for external vessel cooling and corium cooling on the cavity are summarized and provided in this report

  5. Electromagnetic loads and structural response of the CIT [Compact Ignition Tokamak] vacuum vessel to plasma disruptions

    International Nuclear Information System (INIS)

    Salem, S.L.; Listvinsky, G.; Lee, M.Y.; Bailey, C.

    1987-01-01

    Studies of the electromagnetic loads produced by a variety of plasma disruptions, and the resulting structural effects on the compact Ignition Tokamak (CIT) vacuum vessel (VV), have been performed to help optimize the VV design. A series of stationary and moving plasmas, with disruption rates from 0.7--10.0 MA/ms, have been analyzed using the EMPRES code to compute eddy currents and electromagnetic pressures, and the NASTRAN code to evaluate the structural response of the vacuum vessel. Key factors contributing to the magnitude of EM forces and resulting stresses on the vessel have been found to include disruption rate, and direction and synchronization of plasma motion with the onset of plasma current decay. As a result of these analyses, a number of design changes have been made, and design margins for the present 1.75 meter design have been improved over the original CIT configuration. 1 ref., 10 figs., 4 tabs

  6. Unsupervised Retinal Vessel Segmentation Using Combined Filters.

    Directory of Open Access Journals (Sweden)

    Wendeson S Oliveira

    Full Text Available Image segmentation of retinal blood vessels is a process that can help to predict and diagnose cardiovascular related diseases, such as hypertension and diabetes, which are known to affect the retinal blood vessels' appearance. This work proposes an unsupervised method for the segmentation of retinal vessels images using a combined matched filter, Frangi's filter and Gabor Wavelet filter to enhance the images. The combination of these three filters in order to improve the segmentation is the main motivation of this work. We investigate two approaches to perform the filter combination: weighted mean and median ranking. Segmentation methods are tested after the vessel enhancement. Enhanced images with median ranking are segmented using a simple threshold criterion. Two segmentation procedures are applied when considering enhanced retinal images using the weighted mean approach. The first method is based on deformable models and the second uses fuzzy C-means for the image segmentation. The procedure is evaluated using two public image databases, Drive and Stare. The experimental results demonstrate that the proposed methods perform well for vessel segmentation in comparison with state-of-the-art methods.

  7. Trends in Tissue Engineering for Blood Vessels

    Directory of Open Access Journals (Sweden)

    Judee Grace Nemeno-Guanzon

    2012-01-01

    Full Text Available Over the years, cardiovascular diseases continue to increase and affect not only human health but also the economic stability worldwide. The advancement in tissue engineering is contributing a lot in dealing with this immediate need of alleviating human health. Blood vessel diseases are considered as major cardiovascular health problems. Although blood vessel transplantation is the most convenient treatment, it has been delimited due to scarcity of donors and the patient’s conditions. However, tissue-engineered blood vessels are promising alternatives as mode of treatment for blood vessel defects. The purpose of this paper is to show the importance of the advancement on biofabrication technology for treatment of soft tissue defects particularly for vascular tissues. This will also provide an overview and update on the current status of tissue reconstruction especially from autologous stem cells, scaffolds, and scaffold-free cellular transplantable constructs. The discussion of this paper will be focused on the historical view of cardiovascular tissue engineering and stem cell biology. The representative studies featured in this paper are limited within the last decade in order to trace the trend and evolution of techniques for blood vessel tissue engineering.

  8. A Measure of Similarity Between Trajectories of Vessels

    Directory of Open Access Journals (Sweden)

    Le QI

    2016-03-01

    Full Text Available The measurement of similarity between trajectories of vessels is one of the kernel problems that must be addressed to promote the development of maritime intelligent traffic system (ITS. In this study, a new model of trajectory similarity measurement was established to improve the data processing efficiency in dynamic application and to reflect actual sailing behaviors of vessels. In this model, a feature point detection algorithm was proposed to extract feature points, reduce data storage space and save computational resources. A new synthesized distance algorithm was also created to measure the similarity between trajectories by using the extracted feature points. An experiment was conducted to measure the similarity between the real trajectories of vessels. The growth of these trajectories required measurements to be conducted under different voyages. The results show that the similarity measurement between the vessel trajectories is efficient and correct. Comparison of the synthesized distance with the sailing behaviors of vessels proves that results are consistent with actual situations. The experiment results demonstrate the promising application of the proposed model in studying vessel traffic and in supplying reliable data for the development of maritime ITS.

  9. Advanced toroidal facility vaccuum vessel stress analyses

    International Nuclear Information System (INIS)

    Hammonds, C.J.; Mayhall, J.A.

    1987-01-01

    The complex geometry of the Advance Toroidal Facility (ATF) vacuum vessel required special analysis techniques in investigating the structural behavior of the design. The response of a large-scale finite element model was found for transportation and operational loading. Several computer codes and systems, including the National Magnetic Fusion Energy Computer Center Cray machines, were implemented in accomplishing these analyses. The work combined complex methods that taxed the limits of both the codes and the computer systems involved. Using MSC/NASTRAN cyclic-symmetry solutions permitted using only 1/12 of the vessel geometry to mathematically analyze the entire vessel. This allowed the greater detail and accuracy demanded by the complex geometry of the vessel. Critical buckling-pressure analyses were performed with the same model. The development, results, and problems encountered in performing these analyses are described. 5 refs., 3 figs

  10. Method of detecting water leakage in radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishioka, Hitoshi; Takao, Yoshiaki; Hayakawa, Kiyoshige.

    1989-01-01

    Lower level radioactive wastes formed upon operation of nuclear facilities are processed by underground storage. In this case, a plurality of drum cans packed with radioactive wastes are contained in a vessel and a water soluble dye material is placed at the inside of the vessel. The method of placing the water soluble dye material at the inside of the vessel includes a method of coating the material on the inner surface of the vessel and a method of mixing the material in sands to be filled between each of the drum cans. Then, leakage of water soluble dye material is detected when water intruding from the outside into the vessel is again leached out of the vessel, to detect the water leakage from the inside of the vessel. In this way, it is possible to find a water-invaded vessel before corrosion of the drum can by water intruded into the vessel and leakage of nuclides in the drum can. Accordingly, it is possible to apply treatment such as repair before occurrence of accident and can maintain the safety of radioactive water processing facilities. (I.S.)

  11. Sensitivity analysis of MIDAS tests using SPACE code. Effect of nodalization

    International Nuclear Information System (INIS)

    Eom, Shin; Oh, Seung-Jong; Diab, Aya

    2018-01-01

    The nodalization sensitivity analysis for the ECCS (Emergency Core Cooling System) bypass phe�nomena was performed using the SPACE (Safety and Performance Analysis CodE) thermal hydraulic analysis computer code. The results of MIDAS (Multi-�dimensional Investigation in Downcomer Annulus Simulation) test were used. The MIDAS test was conducted by the KAERI (Korea Atomic Energy Research Institute) for the performance evaluation of the ECC (Emergency Core Cooling) bypass phenomenon in the DVI (Direct Vessel Injection) system. The main aim of this study is to examine the sensitivity of the SPACE code results to the number of thermal hydraulic channels used to model the annulus region in the MIDAS experiment. The numerical model involves three nodalization cases (4, 6, and 12 channels) and the result show that the effect of nodalization on the bypass fraction for the high steam flow rate MIDAS tests is minimal. For computational efficiency, a 4 channel representation is recommended for the SPACE code nodalization. For the low steam flow rate tests, the SPACE code over-�predicts the bypass fraction irrespective of the nodalization finesse. The over-�prediction at low steam flow may be attributed to the difficulty to accurately represent the flow regime in the vicinity of the broken cold leg.

  12. Sensitivity analysis of MIDAS tests using SPACE code. Effect of nodalization

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Shin; Oh, Seung-Jong; Diab, Aya [KEPCO International Nuclear Graduate School (KINGS), Ulsan (Korea, Republic of). Dept. of NPP Engineering

    2018-02-15

    The nodalization sensitivity analysis for the ECCS (Emergency Core Cooling System) bypass phe�nomena was performed using the SPACE (Safety and Performance Analysis CodE) thermal hydraulic analysis computer code. The results of MIDAS (Multi-�dimensional Investigation in Downcomer Annulus Simulation) test were used. The MIDAS test was conducted by the KAERI (Korea Atomic Energy Research Institute) for the performance evaluation of the ECC (Emergency Core Cooling) bypass phenomenon in the DVI (Direct Vessel Injection) system. The main aim of this study is to examine the sensitivity of the SPACE code results to the number of thermal hydraulic channels used to model the annulus region in the MIDAS experiment. The numerical model involves three nodalization cases (4, 6, and 12 channels) and the result show that the effect of nodalization on the bypass fraction for the high steam flow rate MIDAS tests is minimal. For computational efficiency, a 4 channel representation is recommended for the SPACE code nodalization. For the low steam flow rate tests, the SPACE code over-�predicts the bypass fraction irrespective of the nodalization finesse. The over-�prediction at low steam flow may be attributed to the difficulty to accurately represent the flow regime in the vicinity of the broken cold leg.

  13. Structural Analysis of the NCSX Vacuum Vessel

    International Nuclear Information System (INIS)

    Fred Dahlgren; Art Brooks; Paul Goranson; Mike Cole; Peter Titus

    2004-01-01

    The NCSX (National Compact Stellarator Experiment) vacuum vessel has a rather unique shape being very closely coupled topologically to the three-fold stellarator symmetry of the plasma it contains. This shape does not permit the use of the common forms of pressure vessel analysis and necessitates the reliance on finite element analysis. The current paper describes the NCSX vacuum vessel stress analysis including external pressure, thermal, and electro-magnetic loading from internal plasma disruptions and bakeout temperatures of up to 400 degrees centigrade. Buckling and dynamic loading conditions are also considered

  14. 75 FR 29358 - Maritime Security Directive 104-6 (Rev 2 and 3); Guidelines for U.S. Vessels Operating in High...

    Science.gov (United States)

    2010-05-25

    ... designated high risk waters, and provides additional anti-piracy guidance and mandatory measures for these vessels operating in these areas where acts of piracy and armed robbery against ships are prevalent... piratical activities. The combination of piracy and weak rule of law in the region offers a potential...

  15. Holographic and acoustic emission evaluation of pressure vessels

    International Nuclear Information System (INIS)

    Boyd, D.M.

    1980-01-01

    Optical holographic interfereometry and acoustic emission monitoring were simultaneously used to evaluate two small, high pressure vessels during pressurization. The techniques provide pressure vessel designers with both quantitative information such as displacement/strain measurements and qualitative information such as flaw detection. The data from the holographic interferograms were analyzed for strain profiles. The acoustic emission signals were monitored for crack growth and vessel quality

  16. Neutron Assay System for Con?nement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Waste will be removed from confinement vessels remaining from 1970s-era experiments. Los Alamos has 9+ spherical confinement vessels remaining from experiments. Each vessel contains ∼ 500 lbs of radioactive debris such as actinide metals and oxides, metals, powdered silica, graphite, and wires and hardware. In order to dispose of the vessels, debris and contamination must be removed. Neutron assay system was designed to assay vessels before and after cleanout. System requirements are: (1) Modular and moveable; (2) Capable of detecting ∼100g 239 Pu equivalent in a 2-inch thick steel sphere with 6 foot diameter; and (3) Capable of safeguards-quality assays. Initial design parameters arethe use of 4-atm 3 He tubes with length of 6 feet, and 3 He tubes embedded in polyethelene for moderation. This paper describes the calibration of the Confinement Vessel Assay System (CVAS) and quantification of its uncertainties. Assay uncertainty depends on five factors: (1) Statistical uncertainty in the assay measurement; (2) Statistical uncertainty in the background measurement; (3) Statistical uncertainty in the isotopics determination - This should be much smaller than the other uncertainties; (4) Systematic uncertainty due to position bias; and (5) Systematic uncertainty due to fluctuations in cosmic ray spallation. This one can be virtually eliminated by performing the background measurement with an empty vessel - but that may not be possible. We used modeling and experiments to quantify the systematic uncertainties. The calibration assumes a uniform distribution of material, but reality will be different. MCNPX modeling was used to quantify the positional bias. The model was benchmarked to build confidence in its results. Material at top of vessel is 44% greater than amount assayed, according to singles. Material near 19-tube detector is 38% less than amount assayed, according to singles. Cosmic ray spallation contributes significantly to the background. Comparing rates

  17. A thermal insulation system intended for a prestressed concrete vessel

    International Nuclear Information System (INIS)

    Aubert, Gilles; Petit, Guy.

    1975-01-01

    The description is given of a thermal insulation system withstanding the pressure of a vaporisable fluid for a prestressed concrete vessel, particularly the vessel of a boiling water nuclear reactor. The ring in the lower part of the vessel has, between the fluid inlet pipes and the bottom of the vessel, an annular opening of which the bottom edge is integral with an annular part rising inside the ring and parallel to it. This ring is hermetically connected to the bottom of the vessel and is coated with a metal lagging, at least facing the annular opening. This annular opening is made in the ring half-way up between the fluid inlet pipes and the bottom of the vessel. It is connected to the bottom of the vessel through the internal structure enveloping the reactor core [fr

  18. In-vessel core debris retention experiments. Final report

    International Nuclear Information System (INIS)

    1998-10-01

    The in-vessel cooling experimental program (Phase 1 and 2) was motivated by the survivability of the TMI lower vessel head during the TMI-2 accident. During that accident, molten debris relocation into the water filled lower head resulted in a localized hot spot in the lower head, but no lower head failure occurred. A postulated set of mechanisms which could be involved in and responsible for the survivability of the TMI lower head were identified and experimentally investigated as part of this program. These mechanisms included: the formation of a gap (contact resistance) between the relocated and frozen debris and the vessel wall was a key aspect of the in-vessel cooling mechanism; wall heatup due to the relocated debris in the presence of wall stress due to a pressure gradient across the vessel wall; gap growth due to a lack of debris adherence to the vessel wall and material creep of the heated vessel wall; and the potential for enhanced wall cooling due to gap growth. Each of these postulated mechanisms was investigated in this experimental program. This report summarizes the several insights and conclusions that were obtained from this experimental program. This report documents the entire set of five experiments completed in Phase 2 of this experimental program. Results from the Phase 1 effort were used to plan and select the Phase 2 test matrix. Conclusions from the Phase 1 and 2 experiments are identified and recommendations for future work are provided

  19. Benchmark study of shear buckling of a cylindrical vessel

    International Nuclear Information System (INIS)

    Dostal, M.; Austin, N.M.; Peano, A.; Combescure, A.; Bastien, R.; Carnoy, E.G.

    1986-01-01

    The possibility of a buckling failure of the primary vessel subjected to seismic excitation has been considered, by all major designers of loop and pool type liquid metal cooled fast breeder reactors. The problem is particularly onerous in this type of reactor due to their large size, coupled with small wall thicknesses. This report details the results of the first phase in a joint European code validation exercise on the static shear buckling behaviour of thin, low aspect ratio stainless steel cylinders. Linear and non-linear finite element analyses were performed by four organizations using three different computer codes, i.e. NNC (UK)-ABAQUS, ISMES (Italy)-ABAQUS, CEA (France)-BILBO/INCA and NOVATOME (France)-NOVNL. The computed results were compared directly with experimental results. It was discovered that refined finite element models were essential if accurate buckling loads were to be calculated. Buckling analyses in 3D were therefore computationally expensive and 2D analyses, where applicable, proved an useful alternative. Traditional linear (Euler) bifurcation analysis seriously over-estimated the buckling loads by around 50 %. Extrapolation techniques can however be used to reduce this discrepancy. Elasto-plastic bifurcation analysis predicted conservative buckling loads close to the experimental value. Non-linear, large displacement analyses were performed on the vessel. The effect of geometrical imperfections in the vessel was considered. These analyses all over-estimated the experimental buckling load by 10 %-25 % and appeared to be largely insensitive to the initial imperfection size. Each of the codes appeared to predict reasonably well the final buckled geometry although the analytical load-deflection estimate did not agree exactly with the experiment

  20. Summary of Reported Whale-Vessel Collisions in Alaskan Waters

    Directory of Open Access Journals (Sweden)

    Janet L. Neilson

    2012-01-01

    Full Text Available Here we summarize 108 reported whale-vessel collisions in Alaska from 1978–2011, of which 25 are known to have resulted in the whale's death. We found 89 definite and 19 possible/probable strikes based on standard criteria we created for this study. Most strikes involved humpback whales (86% with six other species documented. Small vessel strikes were most common (<15 m, 60%, but medium (15–79 m, 27% and large (≥80 m, 13% vessels also struck whales. Among the 25 mortalities, vessel length was known in seven cases (190–294 m and vessel speed was known in three cases (12–19 kn. In 36 cases, human injury or property damage resulted from the collision, and at least 15 people were thrown into the water. In 15 cases humpback whales struck anchored or drifting vessels, suggesting the whales did not detect the vessels. Documenting collisions in Alaska will remain challenging due to remoteness and resource limitations. For a better understanding of the factors contributing to lethal collisions, we recommend (1 systematic documentation of collisions, including vessel size and speed; (2 greater efforts to necropsy stranded whales; (3 using experienced teams focused on determining cause of death; (4 using standard criteria for validating collision reports, such as those presented in this paper.

  1. Nuclear reactor with a suspended vessel

    International Nuclear Information System (INIS)

    Lemercier, Guy.

    1977-01-01

    This invention relates to a nuclear reactor with a suspended vessel and applies in particular when this is a fast reactor, the core or active part of the reactor being inside the vessel and immersed under a suitable volume of flowing liquid metal to cool it by extracting the calories released by the nuclear fission in the fuel assemblies forming this core [fr

  2. Results of reactor pressure vessels ISI

    International Nuclear Information System (INIS)

    Cepcek, S.

    1994-01-01

    To find out the possible influence of the annealing process to reactor pressure vessel integrity, a large in-service inspection programme has been implemented as an associated activity to reactor pressure vessel annealing. In this paper the approach to the RPV in-service inspection is shown. Also, the main results and conclusions following in-service inspection are presented. (author). 3 refs, 1 fig

  3. Safety design of Pb-Bi-cooled direct contact boiling water fast reactor (PBWFR)

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Uchida, Shoji; Yamada, Yumi; Koyama, Kazuya

    2008-01-01

    In Pb-Bi-cooled direct contact boiling water small fast reactor (PBWFR), steam is generated by direct contact of feedwater with primary Pb-Bi coolant above the core, and Pb-Bi coolant is circulated by steam lift pump in chimneys. Safety design has been developed to show safety features of PBWFR. Negative void reactivity is inserted even if whole of the core and upper plenum are voided hypothetically by steam intrusion from above. The control rod ejection due to coolant pressure is prevented using in-vessel type control rod driving mechanism. At coolant leak from reactor vessel and feedwater pipes, Pb-Bi coolant level in the reactor vessel required for decay heat removal is kept using closed guard vessel. Dual pipes for feedwater are employed to avoid leak of water. Although there is no concern of loss of flow accident due to primary pump trip, feedwater pump trip initiates loss of coolant flow (LOF). Injection of high pressure water slows down the flow coast down of feedwater at the LOF event. The unprotected loss of flow and heat sink (ATWS) has been evaluated, which shows that the fuel temperatures are kept lower than the safety limits. (author)

  4. Analysis of Fundus Fluorescein Angiogram Based on the Hessian Matrix of Directional Curvelet Sub-bands and Distance Regularized Level Set Evolution.

    Science.gov (United States)

    Soltanipour, Asieh; Sadri, Saeed; Rabbani, Hossein; Akhlaghi, Mohammad Reza

    2015-01-01

    This paper presents a new procedure for automatic extraction of the blood vessels and optic disk (OD) in fundus fluorescein angiogram (FFA). In order to extract blood vessel centerlines, the algorithm of vessel extraction starts with the analysis of directional images resulting from sub-bands of fast discrete curvelet transform (FDCT) in the similar directions and different scales. For this purpose, each directional image is processed by using information of the first order derivative and eigenvalues obtained from the Hessian matrix. The final vessel segmentation is obtained using a simple region growing algorithm iteratively, which merges centerline images with the contents of images resulting from modified top-hat transform followed by bit plane slicing. After extracting blood vessels from FFA image, candidates regions for OD are enhanced by removing blood vessels from the FFA image, using multi-structure elements morphology, and modification of FDCT coefficients. Then, canny edge detector and Hough transform are applied to the reconstructed image to extract the boundary of candidate regions. At the next step, the information of the main arc of the retinal vessels surrounding the OD region is used to extract the actual location of the OD. Finally, the OD boundary is detected by applying distance regularized level set evolution. The proposed method was tested on the FFA images from angiography unit of Isfahan Feiz Hospital, containing 70 FFA images from different diabetic retinopathy stages. The experimental results show the accuracy more than 93% for vessel segmentation and more than 87% for OD boundary extraction.

  5. 46 CFR 2.10-105 - Prepayment of annual vessel inspection fees.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Prepayment of annual vessel inspection fees. 2.10-105... VESSEL INSPECTIONS Fees § 2.10-105 Prepayment of annual vessel inspection fees. (a) Vessel owners may prepay the annual vessel inspection fee for any period of not less than three years, and not more than...

  6. Tubular inverse opal scaffolds for biomimetic vessels

    Science.gov (United States)

    Zhao, Ze; Wang, Jie; Lu, Jie; Yu, Yunru; Fu, Fanfan; Wang, Huan; Liu, Yuxiao; Zhao, Yuanjin; Gu, Zhongze

    2016-07-01

    There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially oriented elliptical pattern microstructures on their surfaces. It is demonstrated that these tailored tubular scaffolds can effectively make endothelial cells to form an integrated hollow tubular structure on their inner surface and induce smooth muscle cells to form a circumferential orientation on their outer surface. These features of our tubular scaffolds make them highly promising for the construction of biomimetic blood vessels.There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially

  7. 33 CFR 104.145 - Maritime Security (MARSEC) Directive.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Maritime Security (MARSEC) Directive. 104.145 Section 104.145 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MARITIME SECURITY MARITIME SECURITY: VESSELS General § 104.145 Maritime Security (MARSEC...

  8. Cooling system for the connecting rings of a fast neutron reactor vessel

    International Nuclear Information System (INIS)

    Martin, J.-P.; Malaval, Claude

    1974-01-01

    A description is given of a cooling system for the vessel connecting rings of a fast neutron nuclear reactor, particularly of a main vessel containing the core of the reactor and a volume of liquid metal coolant at high temperature and a safety vessel around the main vessel, both vessels being suspended to a rigid upper slab kept at a lower temperature. It is mounted in the annular space between the two vessels and includes a neutral gas circuit set up between the wall of the main vessel to be cooled and that of the safety vessel itself cooled from outer. The neutral gas system comprises a plurality of ventilators fitted in holes made through the thickness of the upper slab and opening on to the space between the two vessels. It also includes two envelopes lining the walls of these vessels, establishing with them small section channels for the circulation of the neutral gas cooled against the safety vessel and heated against the main vessel [fr

  9. Elastic plastic buckling of elliptical vessel heads

    International Nuclear Information System (INIS)

    Alix, M.; Roche, R.L.

    1981-08-01

    The risks of buckling of dished vessel head increase when the vessel is thin walled. This paper gives the last results on experimental tests of 3 elliptical heads and compares all the results with some empirical formula dealing with elastic and plastic buckling

  10. Stress analyses for reactor pressure vessels by the example of a product line '69 boiling water reactor

    International Nuclear Information System (INIS)

    Mkrtchyan, Lilit; Schau, Henry; Wolf, Werner; Holzer, Wieland; Wernicke, Robert; Trieglaff, Ralf

    2011-01-01

    The reactor pressure vessels (RPV) of boiling water reactors (BWR) belonging to the product line '69 have unusually designed heads. The spherical cap-shaped bottom head of the vessel is welded directly to the support flange of the lower shell course. This unusual construction has led repeatedly to controversial discussions concerning the limits and admissibility of stress intensities arising in the junction of the bottom head to the cylindrical shell. In the present paper, stress analyses for the design conditions are performed with the finite element method in order to determine and categorize the occurring stresses. The procedure of stress classification in accordance with the guidelines of German KTA 3201.2 and Section III of the ASME Code (Subsection NB) is described and subsequently demonstrated by the example of a typical BWR vessel. The accomplished investigations yield allowable stress intensities in the considered area. Additionally, limit load analyses are carried out to verify the obtained results. Complementary studies, performed for a torispherical head, prove that the determined maximum peak stresses in the junction between the bottom head and the cylindrical shell are not unusual also for pressure vessels with regular bottom head constructions. (orig.)

  11. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    The retinal blood vessels were segmented through color space conversion and color channel .... Retinal blood vessel segmentation was also attempted through multi-scale operators. A few works in this ... fundus camera at 35 degrees field of view. The image ... vessel segmentation is available from two human observers.

  12. Pressure vessel for a BWR type reactor

    International Nuclear Information System (INIS)

    Shimamoto, Yoshiharu.

    1980-01-01

    Purpose: To prevent the retention of low temperature water and also prevent the thermal fatigue of the pressure vessel by making large the curvature radius of a pressure vessel of a feed water sparger fitting portion and accelerating the mixing of low-temperature water at the feed water sparger base and in-pile hot water. Constitution: The curvature radius of the corner of the feed water sparger fitting portion in a pressure vessel is formed largely. In-pile circulating water infiltrates up to the base portion of the feed water sparger to carry outside low-temperature water at the base part, which is mixed with in-pile hot water. Accordingly, low temperature water does not stay at the base portion of the feed water sparger and generation of thermal fatigue in the pressure vessel can be prevented and the safety of the BWR type reactor can be improved. (Yoshino, Y.)

  13. Some aspects of reactor pressure vessel integrity

    International Nuclear Information System (INIS)

    Korosec, D.; Vojvodic, G.J.

    1996-01-01

    Reactor pressure vessel of the pressurized water reactor nuclear power plant is the subject of extreme interest due to the fact that presents the pressure boundary of the reactor coolant system, which is under extreme thermal, mechanical and irradiation effects. Reactor pressure vessel by itself prevents the release of fission products to the environment. Design, construction and in-service inspection of such component is governed by strict ASME rules and other forms of administrative control. The reactor pressure vessel in nuclear power plant Kriko is designed and constructed in accordance with related ASME rules. The in-service inspection program includes all requests presented in ASME Code section XI. In the present article all major requests for the periodic inspections of reactor pressure vessel and fracture mechanics analysis are discussed. Detailed and strict fulfillment of all prescribed provisions guarantee the appropriate level of nuclear safety. (author)

  14. 19 CFR 4.1 - Boarding of vessels; cutter and dock passes.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Boarding of vessels; cutter and dock passes. 4.1... OF THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Arrival and Entry of Vessels § 4.1 Boarding of... regulations. (4) The master of any vessel shall not authorize the boarding or leaving of his vessel by any...

  15. Stress criteria for nuclear vessel concrete

    International Nuclear Information System (INIS)

    Costes, D.

    1975-01-01

    Concrete nuclear vessels are submitted to prestressing forces which limit tensile stresses in concrete when the vessel is under pressure with thermal gradients. Hence, the most severe conditions for concrete appear when the vessel is prestressed and not submitted to internal pressure. The triaxial states of stress in the concrete may be computed postulating elastic or other behavior and compared with safe limits obtained from rupture tests and fatigue tests. The first part of the paper, recalls experimental rupture results and the acceptability procedures currently used. Criteria founded on the lemniscoid surfaces are proposed, parameters for which are obtained by various tests and safety considerations. In the second part, rupture tests are reported on small, thick, cylindrical vessels submitted to external hydraulic pressure simulating prestressing forces. Materials used are plain concrete, microconcrete, marble and graphite. The strengths obtained are much higher than those which could be elastically computed, triaxial rupture states being provided by previous experiments. Such results may be due to a plastic stress redistribution before fracture and to stabilizing effects of stress gradients around the more stressed areas. Fatigue tests by external hydraulic loading are reported [fr

  16. Thermal-buckling analysis of an LMFBR overflow vessel

    International Nuclear Information System (INIS)

    Severud, L.K.

    1983-01-01

    During a reactor scram, cold sodium flows into the hot overflow vessel. The effect on the vessel is a compressive thermal stress in a zone just above the sodium level. This condition must be sufficiently controlled to preclude thermal buckling. Also, under repeated scrams, the vessel should not suffer thermal stress low cycle fatigue. To evaluate the closeness to buckling and satisfaction of ASMA Code limits, a combination of simple approximations, detailed elastic shell buckling analyses, and correlations to results of thermal buckling tests were employed. This paper describes the analysis methods, special considerations, and evaluations accomplished for this FFTF vessel to assure satisfaction of ASME buckling design criteria, rules, and limits

  17. Problems in Pressure Vessel Design and Manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, O [Uddeholms AB, Degerfors (Sweden); Nilson, Ragnar [AB Atomenergi, Nykoeping (Sweden)

    1963-05-15

    The general desire by the power reactor process makers to increase power rating and their efforts to involve more advanced thermal behaviour and fuel handling facilities within the reactor vessels are accompanied by an increase in both pressure vessel dimensions and various difficulties in giving practical solutions of design materials and fabrication problems. In any section of this report it is emphasized that difficulties and problems already met with will meet again in the future vessels but then in modified forms and in many cases more pertinent than before. As for the increase in geometrical size it can be postulated that with use of better materials and adjusted fabrication methods the size problems can be taken proper care of. It seems likely that vessels of sufficient large diameter and height for the largest power output, which is judged as interesting in the next ten year period, can be built without developing totally new site fabrication technique. It is, however, supposed that such a fabrication technique will be feasible though at higher specific costs for the same quality requirements as obtained in shop fabrication. By the postulated use of more efficient vessel material with principally the same good features of easy fabrication in different stages such as preparation, welding, heat treatment etc as ordinary or slightly modified carbon steels the increase in wall thickness might be kept low. There exists, however, a development work to be done for low-alloy steels to prove their justified use in large reactor pressure vessels.

  18. Problems in Pressure Vessel Design and Manufacture

    International Nuclear Information System (INIS)

    Hellstroem, O.; Nilson, Ragnar

    1963-05-01

    The general desire by the power reactor process makers to increase power rating and their efforts to involve more advanced thermal behaviour and fuel handling facilities within the reactor vessels are accompanied by an increase in both pressure vessel dimensions and various difficulties in giving practical solutions of design materials and fabrication problems. In any section of this report it is emphasized that difficulties and problems already met with will meet again in the future vessels but then in modified forms and in many cases more pertinent than before. As for the increase in geometrical size it can be postulated that with use of better materials and adjusted fabrication methods the size problems can be taken proper care of. It seems likely that vessels of sufficient large diameter and height for the largest power output, which is judged as interesting in the next ten year period, can be built without developing totally new site fabrication technique. It is, however, supposed that such a fabrication technique will be feasible though at higher specific costs for the same quality requirements as obtained in shop fabrication. By the postulated use of more efficient vessel material with principally the same good features of easy fabrication in different stages such as preparation, welding, heat treatment etc as ordinary or slightly modified carbon steels the increase in wall thickness might be kept low. There exists, however, a development work to be done for low-alloy steels to prove their justified use in large reactor pressure vessels

  19. Application of material databases for improved reliability of reactor pressure vessels

    International Nuclear Information System (INIS)

    Griesbach, T.J.; Server, W.L.; Beaudoin, B.F.; Burgos, B.N.

    1994-01-01

    A vital part of reactor vessel Life Cycle Management program must begin with an accurate characterization of the vessel material properties. Uncertainties in vessel material properties or use of bounding values may result in unnecessary conservatisms in vessel integrity calculations. These conservatisms may be eliminated through a better understanding of the material properties in reactor vessels, both in the unirradiated and irradiated conditions. Reactor vessel material databases are available for quantifying the chemistry and Charpy shift behavior of individual heats of reactor vessel materials. Application of the databases for vessels with embrittlement concerns has proven to be an effective embrittlement management tool. This paper presents details of database development and applications which demonstrate the value of using material databases for improving material chemistry and for maximizing the data from integrated material surveillance programs

  20. Vessel generator noise as a settlement cue for marine biofouling species.

    Science.gov (United States)

    McDonald, J I; Wilkens, S L; Stanley, J A; Jeffs, A G

    2014-01-01

    Underwater noise is increasing globally, largely due to increased vessel numbers and international ocean trade. Vessels are also a major vector for translocation of non-indigenous marine species which can have serious implications for biosecurity. The possibility that underwater noise from fishing vessels may promote settlement of biofouling on hulls was investigated for the ascidian Ciona intestinalis. Spatial differences in biofouling appear to be correlated with spatial differences in the intensity and frequency of the noise emitted by the vessel's generator. This correlation was confirmed in laboratory experiments where C. intestinalis larvae showed significantly faster settlement and metamorphosis when exposed to the underwater noise produced by the vessel generator. Larval survival rates were also significantly higher in treatments exposed to vessel generator noise. Enhanced settlement attributable to vessel generator noise may indicate that vessels not only provide a suitable fouling substratum, but vessels running generators may be attracting larvae and enhancing their survival and growth.

  1. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  2. 40 CFR 1042.130 - Installation instructions for vessel manufacturers.

    Science.gov (United States)

    2010-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW AND IN-USE MARINE COMPRESSION-IGNITION ENGINES...-speed operation, tell vessel manufacturers not to install the engines in variable-speed applications or... vessel manufacturers. (a) If you sell an engine for someone else to install in a vessel, give the engine...

  3. Manipulator arm for a nuclear reactor vessel inspection device

    International Nuclear Information System (INIS)

    1980-01-01

    A manipulator arm for a reactor vessel in-service inspection apparatus is adapted to transport a transducer array for ultrasonic examination of welds at any point in the vessel. The removal of the inspection device from the reactor vessel in an emergency presents a problem where a relatively long manipulator arm is used. This invention provides an improved arm with means for changing the normal orientation of the arm to a shorter one to permit safe removal of the inspection device from the reactor vessel. (author)

  4. Distribution of normal superficial ocular vessels in digital images.

    Science.gov (United States)

    Banaee, Touka; Ehsaei, Asieh; Pourreza, Hamidreza; Khajedaluee, Mohammad; Abrishami, Mojtaba; Basiri, Mohsen; Daneshvar Kakhki, Ramin; Pourreza, Reza

    2014-02-01

    To investigate the distribution of different-sized vessels in the digital images of the ocular surface, an endeavor which may provide useful information for future studies. This study included 295 healthy individuals. From each participant, four digital photographs of the superior and inferior conjunctivae of both eyes, with a fixed succession of photography (right upper, right lower, left upper, left lower), were taken with a slit lamp mounted camera. Photographs were then analyzed by a previously described algorithm for vessel detection in the digital images. The area (of the image) occupied by vessels (AOV) of different sizes was measured. Height, weight, fasting blood sugar (FBS) and hemoglobin levels were also measured and the relationship between these parameters and the AOV was investigated. These findings indicated a statistically significant difference in the distribution of the AOV among the four conjunctival areas. No significant correlations were noted between the AOV of each conjunctival area and the different demographic and biometric factors. Medium-sized vessels were the most abundant vessels in the photographs of the four investigated conjunctival areas. The AOV of the different sizes of vessels follows a normal distribution curve in the four areas of the conjunctiva. The distribution of the vessels in successive photographs changes in a specific manner, with the mean AOV becoming larger as the photos were taken from the right upper to the left lower area. The AOV of vessel sizes has a normal distribution curve and medium-sized vessels occupy the largest area of the photograph. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Laparoscopic prototype for optical sealing of renal blood vessels

    Science.gov (United States)

    Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.

    2017-02-01

    Energy-based, radiofrequency and ultrasonic devices provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternative for vessel sealing with less collateral thermal damage. Previous studies demonstrated vessel sealing in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices in surgical use was developed, and tests were conducted on porcine renal blood vessels. The 5-mm-OD prototype featured a traditional Maryland jaw configuration. Laser energy was delivered through a 550-μm-core fiber and side-delivery from the lower jaw, with beam dimensions of 18-mm-length x 1.2-mm-width. The 1470-nm diode laser delivered 68 W with 3 s activation time. A total of 69 porcine renal vessels with mean diameter of 3.3 +/- 1.7 mm were tested, ex vivo. Vessels smaller than 5 mm were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038 +/- 474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174 +/- 221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7 +/- 0.8, 3.4 +/- 0.7, and 1.0 +/- 0.4 mm. A novel optical laparoscopic prototype with 5-mm- OD shaft integrated within a standard Maryland jaw design consistently sealed vessels less than 5 mm with minimal thermal spread. Further in vivo studies are planned to test performance across a variety of vessels and tissues.

  6. A study of reactor vessel integrity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hoon [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Kim, Jong Kyung; Shin, Chang Ho; Seo, Bo Kyun [Hanyang Univ., Seoul (Korea, Republic of)

    1999-02-15

    The fast neutron fluence at the Reactor Pressure Vessel(RPV) of KNGR designed for 60 years lifetime was calculated by full-scope Monte Carlo simulation for reactor vessel integrity assessment. KNGR core geometry was modeled on a three-dimensional representation of the one-sixteenth of the reactor in-vessel component. Each fuel assemblies were modeled explicitly, and each fuel pins were axially divided into 5 segments. The maximum flux of 4.3 x 10{sup 10} neutrons/cm{sup 2}. sec at the RPV was obtained by tallying neutrons crossing the beltline of inner surface of the RPV.

  7. Gas-liquid flow filed in agitated vessels

    International Nuclear Information System (INIS)

    Hormazi, F.; Alaie, M.; Dabir, B.; Ashjaie, M.

    2001-01-01

    Agitated vessels in form of sti reed tank reactors and mixed ferment ors are being used in large numbers of industry. It is more important to develop good, and theoretically sound models for scaling up and design of agitated vessels. In this article, two phase flow (gas-liquid) in a agitated vessel has been investigated numerically. A two-dimensional computational fluid dynamics model, is used to predict the gas-liquid flow. The effects of gas phase, varying gas flow rates and variation of bubbles shape on flow filed of liquid phase are investigated. The numerical results are verified against the experimental data

  8. Heat treatment device for extending the life of a pressure vessel, particularly a reactor pressure vessel

    International Nuclear Information System (INIS)

    Krauss, P.; Mueller, E.; Poerner, H.; Weber, R.

    1979-01-01

    A support body in the form of an insulating cylinder is tightly sealed by connected surfaces at its outer circumference to the inner wall of the pressure vessel. It forms an annular heating space. The heat treatment or tempering of the pressure vessel takes place with the reactor space empty and screened from the outside by ceiling bolts. Heating gas or an induction winding can be used as the means of heating. (DG) [de

  9. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  10. Dismantling id the reactor pressure vessel insulation and dissecting of the MZFR reactor pressure vessel

    International Nuclear Information System (INIS)

    Loeb, Andreas; Stanke, Dieter; Thoma, Markus; Eisenmann, Beata; Prechtl, Erwin; Dehnke, Burckhard

    2008-01-01

    The MZFR reactor was decommissioned in 1984. The authors describe the dismantling of the reactor pressure vessel insulation that consists of asbestos containing mineral fiber wool. The appropriate remote handling and cutting tools had to be adapted with respect to the restrained space in the containment. The dismantling of the reactor pressure vessel has been completed, the dissected parts have been packaged into 200 containers for the final repository Konrad. During the total project time no reportable events and no damage to persons occurred.

  11. Direct immunofluorescence of normal skin in rheumatoid arthritis.

    Science.gov (United States)

    Fitzgerald, O M; Barnes, L; Woods, R; McHugh, L; Barry, C; O'Loughlin, S

    1985-11-01

    The clinical significance of previously described immunoglobulin and complement deposition in the superficial dermal vessel walls of patients with rheumatoid arthritis is unknown. In the present study, skin biopsies were obtained from the normal forearm and buttock of 48 unselected patients with rheumatoid arthritis and were examined by direct immunofluorescence (IF) for the presence of immunoglobulin (IgG,A,M) and complement (C3) in the vessel walls. Deposits of C3, IgM or IgG were detected in 10 patients. Five patients had deposits at the forearm sample alone, four patients had deposits at both biopsy sites, while one patient was positive at the buttock alone. Clinical features were similar in patients with and without vessel IF. However, patients with IF were significantly more seropositive with lower levels of complement and raised levels of serum IgA and IgM. There was also an increased level of circulating IgG immune complexes in these patients. Further analysis following exclusion of seronegative patients revealed similar results. This study suggests that the presence of vessel IF identifies a subgroup of patients who have evidence of more severe immunological disturbance.

  12. Embrittlement and annealing of reactor pressure vessel steels: comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe vessel

    International Nuclear Information System (INIS)

    Fabry, A.; Chaouadi, T.; Puzzolante, J.L.; Van de Velde, J.; Biemiller, E.C.; Rossinski, S.T.; Carter, R.G.

    1996-07-01

    The sister pressure vessels at the BR3 and Rowe Yankee PWR plants were operated at a lower-than-usual temperature (260 degrees Celsius) and their plates were austenitized at higher-than-usual temperature (970 degrees Celsius). A heat tratemement leading to a coarser microstructure than typical for the fine grain plates that are considered in development of USNRC Regulatory guide 1.99. This material displayed outlier behaviour charackterized by a 41J CVN-shift significantly larger than predicted by Regulatory Guide 1.99. Because lower radiation temperature and nickell alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements enbodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: 1) the accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively, 2) the BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, ANCL was trepanned in early 1995, 3) the accelerated irradiations in the Belgian BR2 test reactor of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is shown that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel anneal was neither necessary nor sufficient. Finally, the sensitivity of embrittlement, annealing and post-annealing reembrittlement to irradiation

  13. Embrittlement and annealing of reactor pressure vessel steels: comparison of BR3 surveillance and vessel plates to the surrogate plates representative of the Yankee Rowe vessel

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A.; Chaouadi, T.; Puzzolante, J.L.; Van de Velde, J. [Centre de l``Etude de l``Energie Nucleaire, Mol (Belgium); Biemiller, E.C. [Yankee Atomic Electric Company, Bolton (United States); Rossinski, S.T.; Carter, R.G. [Electric Power Research Institute, Charlotte (United States)

    1996-07-01

    The sister pressure vessels at the BR3 and Rowe Yankee PWR plants were operated at a lower-than-usual temperature (260 degrees Celsius) and their plates were austenitized at higher-than-usual temperature (970 degrees Celsius). A heat tratemement leading to a coarser microstructure than typical for the fine grain plates that are considered in development of USNRC Regulatory guide 1.99. This material displayed outlier behaviour charackterized by a 41J CVN-shift significantly larger than predicted by Regulatory Guide 1.99. Because lower radiation temperature and nickell alloying are generally considered detrimental to irradiation sensitivity, there was a major concern that the nickel-modified lower Rowe plate and the nickel-modified BR3 plate may become too embrittled to satisfy the toughness requirements enbodied in the PTS screening criterion. This paper compares three complementary studies undertaken to clarify these uncertainties: 1) the accelerated irradiation and test program launched in 1990 by Yankee Atomic Electric Company using typical vessel plate materials containing 0.24% copper at two nickel levels: YA1, 0.63% (A533-B) and YA9, 0.19% (A302-B). These were heat-treated to produce the coarse and fine grain microstructures representative of the Yankee/BR3 and the Regulatory Guide plates, respectively, 2) the BR3 surveillance and vessel testing program: this vessel was wet-annealed in 1984, relicensed for operation till the plant shutdown in 1987, ANCL was trepanned in early 1995, 3) the accelerated irradiations in the Belgian BR2 test reactor of the Yankee coarse grain plates YA1 and YA9 together with BR3 vessel specimens extracted at nozzle elevation, a location with negligible radiation exposure. It is shown that the PTS screening criterion was never attained by the BR3 and Rowe plates, and that the BR3 vessel anneal was neither necessary nor sufficient. Finally, the sensitivity of embrittlement, annealing and post-annealing reembrittlement to irradiation

  14. Shear buckling of cylindrical vessels benchmark exercise

    International Nuclear Information System (INIS)

    Dostal, M; Austin, N.; Combescure, A.; Peano, A.; Angeloni, P.

    1987-01-01

    In Liquid Metal Fast Breeder Reactors (LMFBR) potential shear buckling failures of the primary vessel, induced through seismic excitations, have to be considered. The problem is particularly severe in pool type reactors due to their large size, radius of approximately 10 m, coupled with small wall thicknesses of 50 mm and less. The object of this paper is to provide a comparison of three different computer codes capable of performing buckling analyses and to demonstrate on practical problems the level of accuracy that may be expected in design analyses. Three computer codes were examined ABAQUS, CASTEM (INCA/BILBO) and NOVNL and the computer results were compared directly with experimental data and other commonly used empirical formula. The joint effort was co-ordinated through the CEC Working Group on Codes and Standards AG2. (orig./GL)

  15. Maury Journals - German Vessels

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — German vessels observations, after the 1853 Brussels Conference that set International Maritime Standards, modeled after Maury Marine Standard Observations.

  16. Vessel dilatation in coronary angiograms

    International Nuclear Information System (INIS)

    Hinterauer, L.; Goebel, N.

    1983-01-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment. (orig.) [de

  17. Vessel dilatation in coronary angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Hinterauer, L.; Goebel, N.

    1983-11-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment.

  18. A study of ECC water bypass reduction technology for an improvement of core cooling capability

    International Nuclear Information System (INIS)

    Song, C. G.; Kwon, T. S.; Yun, B. J.

    2006-02-01

    The research for the reduction of ECC water bypass fraction was mainly performed to develop the flow mechanisms that ECC water can penetrate more effectively into a lower downcomer. Evaluation were carried out for the effect of major parameters on the bypass of ECC water in the downcomer with DVI. The following various physical models were derived for the reduction of the bypass fraction of ECC water: models of changing DVI injection angle, models of rearranging relative angles of DVI nozzles, model of grooved-and-subchannel type core barrel, model of dual core barrel. CFD analysis and MARS design verification were performed for the derived models as a first step performance estimation. Through out air-water verification experiments, quantitative evaluation were performed for each model, and three most efficient models were suggested. Examination were carried out for the requirement of structural modification and the change in structural integrity due to the adoption of one of the schemes

  19. Pressure-vessel surveillance dosimetry using solid-state track recorders

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Gold, R.; Roberts, J.H.

    1981-01-01

    In addition to radiometric and SSTR dosimetry sets, helium accumulation fluence monitors, damage monitors, and temperature monitors are being studied. The ideal dosimetry set would monitor neutron fluence, damage, and temperature with as few materials as possible in order to reduce costs and required space. It is hoped that materials such as quartz SSTR and sapphire damage monitors can be developed as multipurpose materials. Sapphire for instance, might be used as a combined fluence and damage monitor (for example, analyzed for helium accumulation, Np 237 fissions, and direct neutron damage). Continuing research will result in the optimization of dosimetry packages for use in long term surveillance of LWR Pressure Vessels

  20. Completely integrated prestressed-concrete reactor pressure vessel, type 'Star'

    International Nuclear Information System (INIS)

    Neunert, B.; Jueptner, G.; Kumpf, H.

    1975-01-01

    The star support vessel is suitable for the connection to all primary circuit systems consisting of a main vessel and a number of satellite vessels around and connected to it, i.e. for LWR, HTR and process reactor. It must be made clear, however, that the PWR in particular with its components does not appear to be suited for the optimum incorporation in a prestressed-concrete pressure vessel system, no matter what kind. There are clear concepts about modifications which, however, require considerable development expenditure. (orig./LH) [de