WorldWideScience

Sample records for dual-site lv pacing

  1. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  2. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  3. Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

    Science.gov (United States)

    Gillis, Anne M

    2014-10-01

    The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.

  4. Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization.

    Science.gov (United States)

    Pappone, C; Rosanio, S; Oreto, G; Tocchi, M; Gulletta, S; Salvati, A; Dicandia, C; Santinelli, V; Mazzone, P; Veglia, F; Ding, J; Sallusti, L; Spinelli, J; Vicedomini, G

    2000-07-01

    Acute left ventricular pacing has been associated with hemodynamic improvement in patients with congestive heart failure and wide QRS complex. We hypothesized that pacing two left ventricular sites simultaneously would produce faster activation and better systolic function than single-site pacing. We selected 14 heart failure patients (NYHA functional class III or IV) in normal sinus rhythm with left bundle branch block and QRS > 150 ms. An 8F dual micromanometer catheter was placed in the aorta for measuring +dP/dt (mmHg/s), aortic pulse pressure (mmHg), and end-diastolic pressure (mmHg). Pacing leads were positioned via coronary veins at the posterior base and lateral wall. Patients were acutely paced VDD at the posterior base, lateral wall, and both sites (dual-site) with 5 atrioventricular delays (from 8 ms to PR -30 ms). Pacing sequences were executed in randomized order using a custom external computer (FlexStim, Guidant CRM). Dual-site pacing increased peak +dP/dt significantly more than posterior base and lateral wall pacing. Dual-site and posterior base pacing raised aortic pulse pressure significantly more than lateral wall pacing. Dual-site pacing shortened QRS duration by 22 %, whereas posterior base and lateral wall pacing increased it by 2 and 12%, respectively (p = 0.006). In heart failure patients with left bundle branch block, dual-site pacing improves systolic function more than single-site stimulation. Improved ventricular activation synchrony, expressed by paced QRS narrowing, may account for the additional benefit of dual- vs single-site pacing in enhancing contractility. This novel approach deserves consideration for future heart failure pacing studies.

  5. Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents.

    Science.gov (United States)

    O'Donnell, David; Sperzel, Johannes; Thibault, Bernard; Rinaldi, Christopher A; Pappone, Carlo; Gutleben, Klaus-Jürgen; Leclercq, Christopher; Razavi, Hedi; Ryu, Kyungmoo; Mcspadden, Luke C; Fischer, Avi; Tomassoni, Gery

    2017-04-01

    The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  6. [Influence of pacing site on myocardial transmural dispersion of repolarization in intact normal and dilated cardiomyopathy dogs].

    Science.gov (United States)

    Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin

    2003-12-25

    In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged

  7. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Nielsen, Jens Cosedis; Thomsen, Poul Erik B; Højberg, Søren

    2011-01-01

    In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any ...

  8. Alternative right ventricular pacing sites.

    Science.gov (United States)

    Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek

    2015-01-01

    The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.

  9. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  10. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study.

    Science.gov (United States)

    Kaye, Gerald C; Linker, Nicholas J; Marwick, Thomas H; Pollock, Lucy; Graham, Laura; Pouliot, Erika; Poloniecki, Jan; Gammage, Michael

    2015-04-07

    Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period. We randomized 240 patients (age 74 ± 11 years, 67% male) with a high-grade AV block requiring >90% ventricular pacing and preserved baseline LVEF >50%, to receive pacing at the RVA (n = 120) or RVHS (n = 120). At 2 years, LVEF decreased in both the RVA (57 ± 9 to 55 ± 9%, P = 0.047) and the RVHS groups (56 ± 10 to 54 ± 10%, P = 0.0003). However, there was no significant difference in intra-patient change in LVEF between confirmed RVA (n = 85) and RVHS (n = 83) lead position (P = 0.43). There were no significant differences in heart failure hospitalization, mortality, the burden of atrial fibrillation, or plasma brain natriutetic peptide levels between the two groups. A significantly greater time was required to place the lead in the RVHS position (70 ± 25 vs. 56 ± 24 min, P function requiring a high percentage of ventricular pacing, RVHS pacing does not provide a protective effect on left ventricular function over RVA pacing in the first 2 years. ClinicalTrials.gov number NCT00461734. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  11. Estimation of the effects of multipoint pacing on battery longevity in routine clinical practice.

    Science.gov (United States)

    Akerström, Finn; Narváez, Irene; Puchol, Alberto; Pachón, Marta; Martín-Sierra, Cristina; Rodríguez-Mañero, Moisés; Rodríguez-Padial, Luis; Arias, Miguel A

    2017-09-23

    Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  12. Biventricular / Left Ventricular Pacing in Hypertrophic Obstructive Cardiomyopathy: An Overview

    Directory of Open Access Journals (Sweden)

    Radu Vatasescu, MD

    2012-05-01

    Full Text Available Hypertrophic cardiomyopathy (HCM is an autosomal dominant inherited genetic disease characterized by compensatory pathological left ventricle (LV hypertrophy due to sarcomere dysfunction. In an important proportion of patients with HCM, the site and extent of cardiac hypertrophy results in severe obstruction to LV outflow tract (LVOT, contributing to disabling symptoms and increasing the risk of sudden cardiac death (SCD. In patients with progressive and/or refractory symptoms despite optimal pharmacological treatment, invasive therapies that diminish or abolish LVOT obstruction relieve heart failure-related symptoms, improve quality of life and could be associated with long-term survival similar to that observed in the general population. The gold standard in this respect is surgical septal myectomy, which might be supplementary associated with a reduction in SCD. Percutaneous techniques, particularly alcohol septal ablation (ASA and more recently radiofrequency (RF septal ablation, can achieve LVOT gradient reduction and symptomatic benefit in a large proportion of HOCM patients at the cost of a supposedly limited septal myocardial necrosis and a 10-20% risk of chronic atrioventricular block. After an initial period of enthusiasm, standard DDD pacing failed to show in randomized trials significant LVOT gradient reductions and objective improvement in exercise capacity. However, case reports and recent small pilot studies suggested that atrial synchronous LV or biventricular (biV pacing significantly reduce LVOT obstruction and improve symptoms (acutely as well as long-term in a large proportion of severely symptomatic HOCM patients not suitable to other gradient reduction therapies. Moreover, biV/LV pacing in HOCM seems to be associated with significant LV reverse remodelling.

  13. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study.

    Science.gov (United States)

    Kantharia, Bharat K; Freedman, Roger A; Hoekenga, David; Tomassoni, Gery; Worley, Seth; Sorrentino, Robert; Steinhaus, David; Wolkowicz, Joel M; Syed, Zaffer A

    2007-11-01

    Different pacing sites and various algorithms have been utilized to prevent atrial fibrillation (AF) in pacemaker recipients. However, the optimal pacing rate settings have not yet been established. In this randomized, prospective, multicentre, single-blinded, cross over study, rate-adaptive pacing at a high base rate (BR) in patients, age 60 years or above, or a history of paroxysmal AF, who underwent dual-chamber (DDD) pacemaker implantation for standard pacing indications, was evaluated for prevention of AF. In the study cohort of 145 patients implanted with DDD pacemakers with a programmable rest rate (RR) feature, the BR/RR settings were sequentially but randomly adjusted as follows: 60 bpm/Off for the baseline quarter (initial 3 months) and then to either 'A-B-C' or 'C-B-A' settings (A = 70/65 bpm, B = 70/Off, C = 80/65 bpm) for the subsequent quarters each of 3 months duration. Data on automatic mode switch episodes, device diagnostics, and a questionnaire evaluating pacemaker awareness and palpitations were collected. Ninety-nine patients, mean age 77 +/- 10 years, who completed the study protocol and followed for 12 months did not show significant differences in the number of mode switch episodes between any settings used. The percentage of atrial pacing was lower during baseline pacing compared to settings A, B, and C (P < 0.0001). Setting C produced a higher percentage of atrial pacing than A and B (P < 0.01). Although a higher percentage of atrial pacing correlated with a lower incidence of mode switch episodes, there was no statistically significant difference in the number of mode switch episodes between settings A, B, and C. There were no significant differences in the questionnaire scores relating to pacemaker awareness or palpitation. Overdrive single-site pacing in the right atrium achieved by programming analysed settings in the present study did not reduce AF as assessed by mode switch episodes. Additionally, no change in the symptoms of

  14. The effect of right ventricular pacing on myocardial oxidative metabolism and efficiency: relation with left ventricular dyssynchrony

    Energy Technology Data Exchange (ETDEWEB)

    Ukkonen, Heikki; Saraste, Antti; Koistinen, Juhani [Turku University Hospital, Department of Medicine, P.O. Box 52, Turku (Finland); Tops, Laurens; Bax, Jeroen [Leiden University Medical Center, Leiden (Netherlands); Naum, Alexander [University of Turku, Turku PET Centre, Turku (Finland); Knuuti, Juhani [University of Turku, Turku PET Centre, Turku (Finland); Turku University Hospital, Turku PET Centre, P.O. Box 52, Turku (Finland)

    2009-12-15

    Right ventricular (RV) apical pacing induces dyssynchrony by a left bundle branch block type electrical activation sequence in the heart and may impair left ventricular (LV) function. Whether these functional changes are accompanied by changes in myocardial perfusion, oxidative metabolism and efficiency, and the relation with the induction of LV dyssynchrony are unknown. Our study was designed to investigate the acute effects of RV pacing on these parameters. Ten patients with normal LV ejection fraction and VVI/DDD pacemaker were studied during AAI pacing/sinus rhythm without RV pacing (pacing-OFF) and with RV pacing (pacing-ON) at the same heart rate. Dynamic [{sup 15}O]water and [{sup 11}C]acetate positron emission tomography was used to measure perfusion and oxidative metabolism (k{sub mono}) of the LV. An echocardiographic examination was used to assess LV stroke volume (SV) and LV dyssynchrony. Myocardial efficiency of forward work was calculated as systolic blood pressure x cardiac output/LV mass/k{sub mono}. RV pacing decreased SV in all subjects (mean decrease 13%, from 76 {+-} 7 to 66 {+-} 7 ml, p = 0.004), but global perfusion and k{sub mono} were unchanged. The efficiency tended to be lower with pacing-ON (70 {+-} 20 vs 81 {+-} 21 mmHg l/g, p = 0.066). In patients with dyssynchrony during pacing (n = 6) efficiency decreased by 23% (from 78 {+-} 25 to 60 {+-} 14 mmHg l/g, p = 0.02), but in patients without dyssynchrony no change in efficiency was detected. Accordingly, heterogeneity in myocardial perfusion and oxidative metabolism was detected during pacing in patients with dyssynchrony but not in those without dyssynchrony. RV pacing resulted in a significant decrease in SV. However, deleterious effects on LV oxidative metabolism and efficiency were observed only in patients with dyssynchrony during RV pacing. (orig.)

  15. Dual-dye optical mapping after myocardial infarction: does the site of ventricular stimulation alter the properties of electrical propagation?

    Science.gov (United States)

    Saba, Samir; Mathier, Michael A; Mehdi, Haider; Liu, Tong; Choi, Bum-Rak; London, Barry; Salama, Guy

    2008-02-01

    Myocardial infarction (MI) disrupts electrical conduction in affected ventricular areas. We investigated the effect of MI on the regional voltage and calcium (Ca) signals and their propagation properties, with special attention to the effect of the site of ventricular pacing on these properties. New Zealand White rabbits were divided into four study groups: sham-operated (C, n = 6), MI with no pacing (MI, n = 7), MI with right ventricular pacing (MI + RV, n = 6), and MI with BIV pacing (MI + BIV, n = 7). At 4 weeks, hearts were excised, perfused, and optically mapped. As previously shown, systolic and diastolic dilation of the LV were prevented by BIV pacing, as was the reduction in LV fractional shortening. Four weeks after MI, optical mapping revealed markedly reduced action potential amplitudes and conduction velocities (CV) in MI zones, and these increased gradually in the border zone and normal myocardial areas. Also, Ca transients were absent in the infarcted areas and increased gradually 3-5 mm from the border of the normal zone. Neither BIV nor RV pacing affected these findings in any of the MI, border, or normal zones. MI has profound effects on the regional electrical and Ca signals and on their propagation properties in this rabbit model. The absence of differences in these parameters by study group suggests that altering the properties of myocardial electrical conduction and Ca signaling are unlikely mechanisms by which BIV pacing confers its benefits. Further studies into the regional, cellular, and molecular benefits of BIV pacing are therefore warranted.

  16. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  17. The Effect of Right Ventricular Apical and Nonapical Pacing on the Short- and Long-Term Changes in Left Ventricular Ejection Fraction: A Systematic Review and Meta-Analysis of Randomized-Controlled Trials.

    Science.gov (United States)

    Hussain, Mohammad Akhtar; Furuya-Kanamori, Luis; Kaye, Gerald; Clark, Justin; Doi, Suhail A R

    2015-09-01

    The right ventricular apex (RVA) is the traditional lead site for chronic pacing but in some patients may cause impaired left ventricular (LV) systolic function over time. Comparisons with right ventricular nonapical (RVNA) pacing sites have generated inconsistent results and recent meta-analyses have demonstrated unclear benefit due to heterogeneity across studies. A systematic search for randomized controlled trials that compared LV ejection fraction (LVEF) outcomes between RVNA and RVA pacing was performed up to October 2014. Twenty-four studies (n = 1,628 patients) met the inclusion criteria. To avoid between study heterogeneity two homogenous groups were created; group 1 where studies reported a difference (in favor of RVNA pacing) and group 2 where studies reported no difference between pacing sites. For group 1, weighted mean difference between RVNA and RVA pacing in terms of LVEF at follow-up was 5.40% (95% confidence interval [CI]: 3.94-6.87), related in part to group one's RVA arm demonstrating a significant reduction (mean loss -3.31%; 95% CI: -6.19 to -0.43) in LVEF between study baseline and end of follow-up. Neither of these finding were seen in group 2. Weighted regression modeling demonstrated that inclusion of poor baseline LVEF (right ventricular pacing where there is inclusion of impaired baseline LVEF (<40%), RVA pacing is associated with deterioration in LV function relative to RVNA pacing. © 2015 Wiley Periodicals, Inc.

  18. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  19. Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients: the role of left ventricular lead type and placement site.

    Science.gov (United States)

    Biffi, Mauro; Exner, Derek V; Crossley, George H; Ramza, Brian; Coutu, Benoit; Tomassoni, Gery; Kranig, Wolfgang; Li, Shelby; Kristiansen, Nina; Voss, Frederik

    2013-01-01

    Unwanted phrenic nerve stimulation (PNS) has been reported in ∼1 in 4 patients undergoing left ventricular (LV) pacing. The occurrence of PNS over mid-term follow-up and the significance of PNS are less certain. Data from 1307 patients enrolled in pre-market studies of LV leads manufactured by Medtronic (models 4193 and 4195 unipolar, 4194, 4196, 4296, and 4396 bipolar) were pooled. Left ventricular lead location was recorded at implant using a common classification scheme. Phrenic nerve stimulation symptoms were either spontaneously reported or identified at scheduled follow-up visits. A PNS-related complication was defined as PNS resulting in invasive intervention or the termination of LV pacing. Average follow-up was 14.9 months (range 0.0-46.6). Phrenic nerve stimulation symptoms occurred in 169 patients (12.9%). Phrenic nerve stimulation-related complications occurred in 21 of 1307 patients (1.6%); 16 of 738 (2.2%) in the unipolar lead studies, and 5 of 569 (0.9%) in the bipolar lead studies (P = 0.08). Phrenic nerve stimulation was more frequent at middle-lateral/posterior, and apical LV sites (139/1010) vs. basal-posterior/lateral/anterior, and middle-anterior sites (20/297; P= 0.01). As compared with an anterior LV lead position, a lateral LV pacing site was associated with over a four-fold higher risk of PNS (P= 0.005) and an apical LV pacing site was associated with over six-fold higher risk of PNS (P= 0.001). Phrenic nerve stimulation occurred in 13% of patients undergoing LV lead placement and was more common at mid-lateral/posterior, and LV apical sites. Most cases (123/139; 88%) of PNS were mitigated via electrical reprogramming, without the need for invasive intervention.

  20. Single lead atrial vs. dual chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Brandt, Niels H; Kirkfeldt, Rikke Esberg; Nielsen, Jens Cosedis

    2017-01-01

    Aims The DANPACE trial randomized patients with sick sinus syndrome (SSS) to single lead atrial (AAIR) or dual chamber (DDDR) pacemaker (PM). After 5 years follow-up, no difference in overall survival, stroke or heart failure (HF) was observed, whereas risk of atrial fibrillation (AF) and PM...... This register-based long-term follow-up study indicates that there is no difference in mortality among patients with SSS randomized to AAIR or DDDR pacing, even with very long follow-up. Nor is there any difference in risk of AF hospitalization, stroke or HF. The higher rate of pacing mode-change to DDDR...

  1. Will the Conscious-Subconscious Pacing Quagmire Help Elucidate the Mechanisms of Self-Paced Exercise? New Opportunities in Dual Process Theory and Process Tracing Methods.

    Science.gov (United States)

    Micklewright, Dominic; Kegerreis, Sue; Raglin, John; Hettinga, Florentina

    2017-07-01

    The extent to which athletic pacing decisions are made consciously or subconsciously is a prevailing issue. In this article we discuss why the one-dimensional conscious-subconscious debate that has reigned in the pacing literature has suppressed our understanding of the multidimensional processes that occur in pacing decisions. How do we make our decisions in real-life competitive situations? What information do we use and how do we respond to opponents? These are questions that need to be explored and better understood, using smartly designed experiments. The paper provides clarity about key conscious, preconscious, subconscious and unconscious concepts, terms that have previously been used in conflicting and confusing ways. The potential of dual process theory in articulating multidimensional aspects of intuitive and deliberative decision-making processes is discussed in the context of athletic pacing along with associated process-tracing research methods. In attempting to refine pacing models and improve training strategies and psychological skills for athletes, the dual-process framework could be used to gain a clearer understanding of (1) the situational conditions for which either intuitive or deliberative decisions are optimal; (2) how intuitive and deliberative decisions are biased by things such as perception, emotion and experience; and (3) the underlying cognitive mechanisms such as memory, attention allocation, problem solving and hypothetical thought.

  2. Long pacing pulses reduce phrenic nerve stimulation in left ventricular pacing.

    Science.gov (United States)

    Hjortshøj, Søren; Heath, Finn; Haugland, Morten; Eschen, Ole; Thøgersen, Anna Margrethe; Riahi, Sam; Toft, Egon; Struijk, Johannes Jan

    2014-05-01

    Phrenic nerve stimulation is a major obstacle in cardiac resynchronization therapy (CRT). Activation characteristics of the heart and phrenic nerve are different with higher chronaxie for the heart. Therefore, longer pulse durations could be beneficial in preventing phrenic nerve stimulation during CRT due to a decreased threshold for the heart compared with the phrenic nerve. We investigated if long pulse durations decreased left ventricular (LV) thresholds relatively to phrenic nerve thresholds in humans. Eleven patients, with indication for CRT and phrenic nerve stimulation at the intended pacing site, underwent determination of thresholds for the heart and phrenic nerve at different pulse durations (0.3-2.9 milliseconds). The resulting strength duration curves were analyzed by determining chronaxie and rheobase. Comparisons for those parameters were made between the heart and phrenic nerve, and between the models of Weiss and Lapicque as well. In 9 of 11 cases, the thresholds decreased faster for the LV than for the phrenic nerve with increasing pulse duration. In 3 cases, the thresholds changed from unfavorable for LV stimulation to more than a factor 2 in favor of the LV. The greatest change occurred for pulse durations up to 1.5 milliseconds. The chronaxie of the heart was significantly higher than the chronaxie of the phrenic nerve (0.47 milliseconds vs. 0.22 milliseconds [P = 0.029, Lapicque] and 0.79 milliseconds vs. 0.27 milliseconds [P = 0.033, Weiss]). Long pulse durations lead to a decreased threshold of the heart relatively to the phrenic nerve and may prevent stimulation of the phrenic nerve in a clinical setting. © 2013 Wiley Periodicals, Inc.

  3. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  4. Peri-infarct zone pacing to prevent adverse left ventricular remodelling in patients with large myocardial infarction

    DEFF Research Database (Denmark)

    Stone, Gregg W; Chung, Eugene S; Stancak, Branislav

    2016-01-01

    AIMS: We sought to determine whether peri-infarct pacing prevents left ventricular (LV) remodelling and improves functional and clinical outcomes in patients with large first myocardial infarction (MI). METHODS AND RESULTS: A total of 126 patients at 27 international sites within 10 days of onset.......92). There were also no significant between-group differences in the change in LV end-systolic volume or ejection fraction over time. Quality of life, as assessed by the Minnesota Living with Heart Failure (HF) and European Quality of Life-5 Dimension questionnaires and New York Heart Association class, was also...

  5. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Early Right Ventricular Apical Pacing-Induced Gene Expression Alterations Are Associated with Deterioration of Left Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Haiyan Xu

    2017-01-01

    Full Text Available The chronic high-dose right ventricular apical (RVA pacing may have deleterious effects on left ventricular (LV systolic function. We hypothesized that the expression changes of genes regulating cardiomyocyte energy metabolism and contractility were associated with deterioration of LV function in patients who underwent chronic RVA pacing. Sixty patients with complete atrioventricular block and preserved ejection fraction (EF who underwent pacemaker implantation were randomly assigned to either RVA pacing (n=30 group or right ventricular outflow tract (RVOT pacing (n=30 group. The mRNA levels of OPA1 and SERCA2a were significantly lower in the RVA pacing group at 1 month’s follow-up (both p<0.001. Early changes in the expression of selected genes OPA1 and SERCA2a were associated with deterioration in global longitudinal strain (GLS that became apparent months later (p=0.002 and p=0.026, resp. The altered expressions of genes that regulate cardiomyocyte energy metabolism and contractility measured in the peripheral blood at one month following pacemaker implantation were associated with subsequent deterioration in LV dyssynchrony and function in patients with preserved LVEF, who underwent RVA pacing.

  7. The Managed Ventricular pacing versus VVI 40 Pacing (MVP) Trial: clinical background, rationale, design, and implementation.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Miller, Elaine Hogan; Sherfesee, Lou; Sheldon, Todd; Whellan, David

    2006-12-01

    Implantable cardioverter defibrillators (ICDs) reduce mortality among appropriately selected patients who have had or are at risk for life-threatening ventricular arrhythmia. Right ventricular apical (RVA) pacing has been implicated in worsening heart failure and death. The optimal pacemaker mode for bradycardia support while minimizing unnecessary and potentially harmful RVA pacing has not been determined. The Managed Ventricular pacing vs. VVI 40 Pacing Trial (MVP) is a prospective, multicenter, randomized, single-blind, parallel, controlled clinical trial designed to establish whether atrial-based dual-chamber managed ventricular pacing mode (MVP) is equivalent or superior to back-up only ventricular pacing (VVI 40) among patients with standard indications for ICD therapy and no indication for bradycardia pacing. The MVP Trial is designed with 80% power to detect a 10% reduction in the primary endpoint of new or worsening heart failure or all-cause mortality in the MVP-treated group. Approximately 1,000 patients at 80 centers in the United States, Canada, Western Europe, and Israel will be randomized to MVP or VVI 40 pacing after successful implantation of a dual-chamber ICD. Heart failure therapies will be optimized in accordance with evidence-based guidelines. Prespecified secondary endpoints will include ventricular arrhythmias, atrial fibrillation, new indication for bradycardia pacing, health-related quality of life, and cost effectiveness. Enrollment began in October 2004 and concluded in April 2006. The study will be terminated upon recommendation of the Data Monitoring Committee or when the last patient enrolled and surviving has reached a minimum 2 years of follow-up. The MVP Trial will meet the clinical need for carefully designed prospective studies to define the benefits of atrial-based dual-chamber minimal ventricular pacing versus single-chamber ventricular pacing in conventional ICD patients.

  8. Sequential biventricular pacing improves regional contractility, longitudinal function and dyssynchrony in patients with heart failure and prolonged QRS

    Directory of Open Access Journals (Sweden)

    Ring Margareta

    2010-04-01

    Full Text Available Abstract Aims Biventricular pacing (BiP is an effective treatment in systolic heart failure (HF patients with prolonged QRS. However, approximately 35% of the patients receiving BiP are classified as non-responders. The aim of this study is to evaluate the acute effects of VV-optimization on systolic heart function. Methods Twenty-one HF patients aged 72 (46-88 years, QRS 154 (120-190 ms, were studied with echocardiography, Tissue Doppler Imaging (TDI and 3D-echo the first day after receiving a BiP device. TDI was performed; during simultaneous pacing (LV-lead pacing 4 ms before the RV-lead and during sequential pacing (LV 20 and 40 ms before RV and RV 20 and 40 ms before LV-lead pacing. Systolic heart function was studied by tissue tracking (TT for longitudinal function and systolic maximal velocity (SMV for regional contractility and signs of dyssynchrony assessed by time-delays standard deviation of aortic valve opening to SMV, AVO-SMV/SD and tissue synchronization imaging (TSI. Results The TT mean value preoperatively was 4,2 ± 1,5 and increased at simultaneous pacing to 5,0 ± 1,2 mm (p Conclusions VV-optimization in the acute phase improves systolic heart function more than simultaneous BiP pacing. Long-term effects should be evaluated in prospective randomized trials.

  9. Right heart failure due to loss of right ventricular capture in a patient with atrioventricular junction ablation and biventricular pacing.

    Science.gov (United States)

    Raffa, Santi; Fantoni, Cecilia; Restauri, Luigia; Auricchio, Angelo

    2005-10-01

    We describe the case of a patient with atrioventricular (AV) junction ablation and chronic biventricular pacing in which intermittent dysfunction of the right ventricular (RV) lead resulted in left ventricular (LV) stimulation alone and onset of severe right heart failure. Restoration of biventricular pacing by increasing device output and then performing lead revision resolved the issue. This case provides evidence that LV pacing alone in patients with AV junction ablation may lead to severe right heart failure, most likely as a result of iatrogenic mechanical dyssynchrony within the RV. Thus, probably this pacing mode should be avoided in pacemaker-dependent patients with heart failure.

  10. The proviral genome of radiation leukemia virus (RadLV): molecular cloning, restriction analysis and integration sites in tumor cell DNA

    International Nuclear Information System (INIS)

    Janowski, M.; Merregaert, J.; Nuyten, J.M.; Maisin, J.R.

    1984-01-01

    An infectious clone of the linear, unintegrated RadLV provirus was obtained by insertion in the plasmid pBR322. Its restriction map was indistinguishable from that of the majority of the multiple proviral copies, which are found apparently at random sites in the DNA of RadLV-induced rat thymic lymphomas [fr

  11. New method for cardiac resynchronization therapy: Transapical endocardial lead implantation for left ventricular free wall pacing

    NARCIS (Netherlands)

    I. Kassai (Imre); C. Foldesi (Csaba); A. Szekely (Andrea); T. Szili-Torok (Tamas)

    2008-01-01

    textabstractCoronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a significant dislocation rate during follow-up. For these patients, epicardial pacing lead implantation is the most

  12. Is right ventricular mid-septal pacing superior to apical pacing in patients with high degree atrio-ventricular block and moderately depressed left ventricular function?

    Science.gov (United States)

    Chen, Kang; Mao, Ye; Liu, Shao-hua; Wu, Qiong; Luo, Qing-zhi; Pan, Wen-qi; Jin, Qi; Zhang, Ning; Ling, Tian-you; Chen, Ying; Gu, Gang; Shen, Wei-feng; Wu, Li-qun

    2014-06-01

    We are aimed to investigate whether right ventricular mid-septal pacing (RVMSP) is superior to conventional right ventricular apical pacing (RVAP) in improving clinical functional capacity and left ventricular ejection fraction (LVEF) for patients with high-degree atrio-ventricular block and moderately depressed left ventricle (LV) function. Ninety-two patients with high-degree atrio-ventricular block and moderately reduced LVEF (ranging from 35% to 50%) were randomly allocated to RVMSP (n=45) and RVAP (n=47). New York Heart Association (NYHA) functional class, echocardiographic LVEF, and distance during a 6-min walk test (6MWT) were determined at 18 months after pacemaker implantation. Serum levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured using an enzyme-linked immunosorbent assay (ELISA) kit. Compared with baseline, NYHA functional class remained unchanged at 18 months, distance during 6MWT (485 m vs. 517 m) and LVEF (36.7% vs. 41.8%) were increased, but BNP levels were reduced (2352 pg/ml vs. 710 pg/ml) in the RVMSP group compared with those in the RVAP group, especially in patients with LVEF 35%-40% (for all comparisons, Pfunction capacity and LV function measurements were not significantly changed in patients with RVAP, despite the pacing measurements being similar in both groups, such as R-wave amplitude and capture threshold. RVMSP provides a better clinical utility, compared with RVAP, in patients with high-degree atrioventricular block and moderately depressed LV function whose LVEF levels ranged from 35% to 40%.

  13. L.V. switchgear - design and development

    International Nuclear Information System (INIS)

    Armes, D.S.; Brown, R.D.

    1992-01-01

    This work describes the methods employed in the design and development of L.V. switchgear to meet the prospective conditions and operational requirements imposed on equipment at sites of PWR power stations. The work concentrates on the aspects of design, manufacture, qualification work and quality assurance particular to the range of L.V. switchgear distribution boards manufactured by Laurence, Scott and Electromotors Ltd. for Sizewell B Power Station and contrasts this equipment with other equipment for conventional (i.e. non-nuclear) power station purposes. (Author)

  14. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  15. Pacing-induced Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Alex Koo

    2017-10-01

    Full Text Available We present a case of pacing-induced cardiomyopathy. The patient presented with clinical symptoms of dyspnea, leg swelling, and orthopnea several months after a dual-chambered pacemaker was placed for third-degree heart block. The echocardiogram demonstrated a depressed ejection fraction. Coronary angiography was performed, which showed widely patent vessels. Single- and dual-chambered pacemakers create ventricular dyssynchrony, which in turn can cause structural, molecular changes leading to cardiomyopathy. With early intervention of biventricular pacemaker replacement, these changes can be reversible; thus, a timely diagnosis and awareness is warranted.

  16. Adverse effects of permanent atrial fibrillation on heart failure in patients with preserved left ventricular function and chronic right apical pacing for complete heart block.

    Science.gov (United States)

    Lampe, Brigitte; Hammerstingl, Christoph; Schwab, Jörg Otto; Mellert, Fritz; Stoffel-Wagner, Birgit; Grigull, Andreas; Fimmers, Rolf; Maisch, Bernhard; Nickenig, Georg; Lewalter, Thorsten; Yang, Alexander

    2012-10-01

    The impact of atrial fibrillation (AF) on heart failure (HF) was evaluated in patients with preserved left ventricular (LV) function and long-term right ventricular (RV) pacing for complete heart block. Clinical, echocardiographic, and laboratory parameters of HF were assessed in 35 patients with established AF who had undergone ablation of the atrioventricular node and pacemaker implantation (Group A) and 31 patients who received dual-chamber pacing for spontaneous complete heart block (Group B). During a follow-up period of 12.7 ± 7.5 years, New York Heart Association (NYHA) functional class increased from 1.3 ± 0.5 to 2.1 ± 0.6 (p Left ventricular ejection fraction (LVEF) decreased from 59.7 ± 5.1 to 53.0 ± 8.2 (p function were moderately depressed in Group A compared with those in Group B: NYHA class 2.1 ± 0.6 versus 1.6 ± 0.7, p = 0.001; LVEF 53.0 ± 8.2 versus 56.9 ± 7.0 %, p brain natriuretic peptide (NT-proBNP) 1116.8 ± 883.9 versus 622.9 ± 1059.4 pg/ml, p 10 %, increasing NYHA class ≥1, and NT-proBNP levels >1,000 pg/ml. Permanent AF was associated with adverse effects on LV function and symptoms of HF in patients with long-term RV pacing for complete heart block, and appears to play an important role in the development of HF in this specific patient cohort.

  17. Comparison of Long-Term Effect of Dual-Chamber Pacing and Alcohol Septal Ablation in Patients with Hypertrophic Obstructive Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Jan Krejci

    2013-01-01

    Full Text Available Introduction. Nonpharmacological treatment of patients with hypertrophic obstructive cardiomyopathy (HOCM comprises surgical myectomy (SME, alcohol septal ablation (ASA, and dual-chamber (DDD pacing. The aim of the study was to compare the long-term effect of DDD pacing and ASA in symptomatic HOCM patients. Patients and Methods. We evaluated retrospective data from three cardiocenters; there were 24 patients treated with DDD pacing included and 52 treated with ASA followed for 101 ± 49 and 87 ± 23 months, respectively. Results. In the group treated with DDD pacing, the left ventricle outflow tract gradient (LVOTG decreased from 82 ± 44 mmHg to 21 ± 21 mmHg, and NYHA class improved from 2.7 ± 0.5 to 2.1 ± 0.6 (both P<0.001. In the ASA-treated group, a decline in LVOTG from 73 ± 38 mmHg to 24 ± 26 mmHg and reduction in NYHA class from 2.8 ± 0.5 to 1.7 ± 0.8 were observed (both P<0.001. The LVOTG change was similar in both groups (P=0.264, and symptoms were more affected by ASA (P=0.001. Conclusion. ASA and DDD pacing were similarly effective in reducing LVOTG. The symptoms improvement was more expressed in patients treated with ASA.

  18. Prevalence of conduction delay of the right atrium in patients with SSS: implications for pacing site selection.

    Science.gov (United States)

    Verlato, Roberto; Zanon, Francesco; Bertaglia, Emanuele; Turrini, Pietro; Baccillieri, Maria Stella; Baracca, Enrico; Bongiorni, Maria Grazia; Zampiero, Aldo; Zonzin, Pietro; Pascotto, Pietro; Venturini, Diego; Corbucci, Giorgio

    2007-09-01

    To evaluate the prevalence of severe right atrial conduction delay in patients with sinus node dysfunction (SND) and atrial fibrillation (AF) and the effects of pacing in the right atrial appendage (RAA) and in the inter-atrial septum (IAS). Forty-two patients (15 male, 72 +/- 7 years) underwent electrophysiologic study to measure the difference between the conduction time from RAA to coronary sinus ostium during stimulation at 600 ms and after extrastimulus (DeltaCTos). Patients were classified as group A if DeltaCTos > 60 ms and group B if IAS pacing and algorithms ON/OFF. Fifteen patients (36%, group A) had DeltaCTos = 76 +/- 11 ms and 27 patients (64%, group B) had DeltaCTos = 36 +/- 20 ms. Twenty-two patients were paced at the RAA and 20 at the IAS. During the study, no AF recurrences were reported in 11 of 42 (26%) patients, independently of RAA or IAS pacing. Patients from group A and RAA pacing had 0.79 +/- 0.81 episodes of AF/day during DDD, which increased to 1.52 +/- 1.41 episodes of AF/day during DDDR + Alg (P = 0.046). Those with IAS pacing had 0.5 +/- 0.24 episodes of AF/day during DDD, which decreased to 0.06 +/- 0.08 episodes of AF/day during DDDR + Alg (P = 0.06). In group B, no differences were reported between pacing sites and pacing modes. Severe right atrial conduction delay is present in one-third of patients with SND and AF: continuous pacing at the IAS is superior to RAA for AF recurrences. In patients without severe conduction delay, no differences between pacing site or mode were observed.

  19. Seroprevalence of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) in shelter cats on the island of Newfoundland, Canada.

    Science.gov (United States)

    Munro, Hannah J; Berghuis, Lesley; Lang, Andrew S; Rogers, Laura; Whitney, Hugh

    2014-04-01

    Feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) are retroviruses found within domestic and wild cat populations. These viruses cause severe illnesses that eventually lead to death. Housing cats communally for long periods of time makes shelters at high risk for virus transmission among cats. We tested 548 cats from 5 different sites across the island of Newfoundland for FIV and FeLV. The overall seroprevalence was 2.2% and 6.2% for FIV and FeLV, respectively. Two sites had significantly higher seroprevalence of FeLV infection than the other 3 sites. Analysis of sequences from the FeLV env gene (envelope gene) from 6 positive cats showed that 4 fell within the FeLV subtype-A, while 2 sequences were most closely related to FeLV subtype-B and endogenous feline leukemia virus (en FeLV). Varying seroprevalence and the variation in sequences at different sites demonstrate that some shelters are at greater risk of FeLV infections and recombination can occur at sites of high seroprevalence.

  20. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    Science.gov (United States)

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  1. Direct His bundle pacing post AVN ablation.

    Science.gov (United States)

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  2. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  3. Antiarrhythmic properties of atrial pacing.

    Science.gov (United States)

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  4. Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and design.

    Science.gov (United States)

    Quesada, Aurelio; Botto, Gianluca; Erdogan, Ali; Kozak, Milan; Lercher, Peter; Nielsen, Jens Cosedis; Piot, Olivier; Ricci, Renato; Weiss, Christian; Becker, Daniel; Wetzels, Gwenn; De Roy, Luc

    2008-03-01

    Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to conventional pacemaker and implantable cardioverter-defibrillator programming in terms of freedom from hospitalization for cardiovascular causes in a population of patients exposed to long periods of ventricular pacing. PreFER MVP is a prospective, 1:1 parallel, randomized (MVP ON/MVP OFF), single-blinded multi-centre trial. The study population consists of patients with more than 40% ventricular pacing documented with their previous device. Approximately, 600 patients will be randomized and followed for at least 24 months. The primary endpoint comprises cardiovascular hospitalization. The PreFER MVP trial is the first large prospective randomized clinical trial evaluating the effect of MVP in patients with a history of RV pacing.

  5. Truncated Dual-Cap Nucleation Site Development

    Science.gov (United States)

    Matson, Douglas M.; Sander, Paul J.

    2012-01-01

    During heterogeneous nucleation within a metastable mushy-zone, several geometries for nucleation site development must be considered. Traditional spherical dual cap and crevice models are compared to a truncated dual cap to determine the activation energy and critical cluster growth kinetics in ternary Fe-Cr-Ni steel alloys. Results of activation energy results indicate that nucleation is more probable at grain boundaries within the solid than at the solid-liquid interface.

  6. Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study

    Science.gov (United States)

    Leclercq, Christophe; Sadoul, Nicolas; Mont, Lluis; Defaye, Pascal; Osca, Joaquim; Mouton, Elisabeth; Isnard, Richard; Habib, Gilbert; Zamorano, Jose; Derumeaux, Genevieve; Fernandez-Lozano, Ignacio; Dupuis, Jean-Marc; Rouleau, Frédéric; Tassin, Aude; Bordachar, Pierre; Clémenty, Jacques; Lafitte, Stephane; Ploux, Sylvan; Reant, Patricia; Ritter, Philippe; Defaye, Pascal; Jacon, Peggy; Mondesert, Blandine; Saunier, Carole; Vautrin, Estelle; Kacet, Salem; Guedon-Moreau, Laurence; Klug, Didier; Kouakam, Claude; Marechaux, Sylvestre; Marquie, Christelle; Polge, Anne Sophie; Richardson, Marjorie; Chevallier, Philippe; De Breyne, Brigitte; Lotek, Marcin M.; Nonin, Emilie; Pineau, Julien; Deharo, Jean-Claude; Bastard, Emilie; Franceschi, Frédéric; Habib, Gilbert; Jego, Christophe; Peyrouse, Eric; Prevot, Sebastien; Saint-Joseph, Hôpital; Bremondy, Michel; Faure, Jacques; Ferracci, Ange; Lefevre, Jean; Pisapia, Andre; Davy, Jean-Marc; Cransac, Frederic; Cung, Tien Tri; Georger, Frederic; Pasquie, Jean-Luc; Raczka, Franck; Sportouch-Dukhan, Catherine; Sadoul, Nicolas; Blangy, Hugues; Bruntz, Jean-François; Freysz, Luc; Groben, Laurent; Huttin, Olivier; Bammert, Antoine; Burban, Marc; Cebron, Jean-Pierre; Gras, Daniel; Frank, Robert; Duthoit, Guillaume; Hidden-Lucet, Françoise; Himbert, Caroline; Isnard, Richard; Lacotte, Jérôme; Pousset, Françoise; Zerah, Thierry; Leclercq, Christophe; Bellouin, Annaïk; Crocq, Christophe; Deplace, Christian; Donal, Erwan; Hamon, Cécile; Mabo, Philippe; Romain, Olivier; Solnon, Aude; Frederic, Anselme; Bauer, Fabrice; Bernard, Mathieu; Godin, Benedicte; Kurtz, Baptiste; Savoure, Arnaud; Copie, Xavier; Lascault, Gilles; Paziaud, Olivier; Piot, Olivier; Touche, Thierry; Delay, Toulouse Marc; Chilon, Talia; Detis, Nicolas; Duparc, Alexandre; Hebrard, Aurélien; Massabuau, Pierre; Maury, Philippe; Mondoly, Pierre; Rumeau, Philippe; Pasteur, Clinique; Boveda, Serge; Adrover, Laurence; Combes, Nicolas; Deplagne, Antoine; Marco-Baertich, Isabelle; Fondard, Olivier; Martínez, Juan Gabriel; Ibañez Criado, José Luis; Ortuño, Diego; Mont, Lluis; Berruezo, Antonio; Eduard, Belu; Martín, Ana; Merschon, Franco M.; Sitges, Marta; Tolosana, José María; Vidal, Bárbara; Hebron, H. Valle; i Mitjans, Angel Moya; Rodriguez, Oscar Alcalde; Rodriguez Palomares, José Fernando; Rivas, Nuria; Teixidó, Gisela; de Hierro, H. Puerta; Lozano, Ignacio Fernández; Ruiz Bautista, Maria Lorena; Castro, Victor; Cavero, Miguel Angel; Gutierrez, Carlos; Ros, Natalia; de la Victoria, H. Virgen; Alzueta Rodriguez, Francisco Javier; Cabrera, Fernando; Cordero, Alberto Barrera; Peña, José Luis; de Valme Sevilla, H.; Gonzáles, Juan Lealdel Ojo; Garcia Medina, Mª Dolores; Jiménez, Ricardo Pavón; Villagomez, David; de la Salud Toledo, H. Virgen; Castellanos Martinez, Eduardo; Alcalá, Juan; Maicas, Carolina; Arias Palomares, Miguel Angel; Puchol, Alberto; Valencia, H. La Fé; OscaAsensi, Joaquim; Carmona, Anastasio Quesada; De Carranza, Mª José Sancho-Tello; De Ros, José Olagüe; Pareja, Enrique Castro; Pérez, Oscar Cano; Saez, Ana Osa; Hortega, H. Rio; Guilarte, Benito Herreros; Muñoz San Jose, Juan Francisco; Pérez Sanz, Teresa Myriam; Logeart, Damien; Gil, Maria Lopez; Leclercq, Christophe; Lozano, Ignacio Fernandez; de Hierro, H. Puerta; Derumeaux, Genevieve

    2016-01-01

    Abstract Aims Cardiac resynchronization therapy (CRT) is a recommended treatment of heart failure (HF) patients with depressed left ventricular ejection fraction and wide QRS. The optimal right ventricular (RV) lead position being a matter of debate, we sought to examine whether RV septal (RVS) pacing was not inferior to RV apical (RVA) pacing on left ventricular reverse remodelling in patients receiving a CRT-defibrillator. Methods and results Patients (n = 263, age = 63.4 ± 9.5 years) were randomly assigned in a 1:1 ratio to RVS (n = 131) vs. RVA (n = 132) pacing. Left ventricular end-systolic volume (LVESV) reduction between baseline and 6 months was not different between the two groups (−25.3 ± 39.4 mL in RVS group vs. −29.3 ± 44.5 mL in RVA group, P = 0.79). Right ventricular septal pacing was not non-inferior (primary endpoint) to RVA pacing with regard to LVESV reduction (average difference = −4.06 mL; P = 0.006 with a −20 mL non-inferiority margin). The percentage of ‘echo-responders’ defined by LVESV reduction >15% between baseline and 6 months was similar in both groups (50%) with no difference in the time to first HF hospitalization or death (P = 0.532). Procedural or device-related serious adverse events occurred in 68 patients (RVS = 37) with no difference between the two groups (P = 0.401). Conclusion This study demonstrates that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome. No recommendation for optimal RV lead position can hence be drawn from this study. ClinicalTrials. gov number NCT 00833352. PMID:26374852

  7. Diastolic And Systolic Right Ventricular Dysfunction Precedes Left Ventricular Dysfunction In Patients Paced From Right Ventricular Apex

    Directory of Open Access Journals (Sweden)

    Dwivedi SK

    2006-07-01

    Full Text Available Background: Cardiac dysfunction after right ventricular (RV apical pacing is well known but its extent, time frame of appearance and individual effect on left ventricular (LV, RV systolic and diastolic parameters has not evaluated in a systematic fashion. Methods: Patients with symptomatic bradycardia and ACC-AHA Class I indication for permanent pacemaker implantation (PPI were implanted a single chamber (VVI pacemaker. They were followed prospectively by echocardiographic examination which was done at baseline, 1 week, 1 month and 6 months after implantation. Parameters observed were chamber dimensions (M-line, chamber volumes, cardiac output (modified Simpson's method, systolic functions (ejection fraction, pre-ejection period, ejection time and ratio and diastolic functions( isovolumic relaxation time & deceleration time of left and right heart. Results: Forty eight consecutive patients (mean age 65.6±11.8 yrs, 66.7% males, mean EF 61.82±10.36% implanted a VVI pacemaker were enrolled in this study. The first significant change to appear in cardiac function after VVI pacing was in diastolic properties of RV as shown by increase in RV isovolumic relaxation time (IVRT from 65.89±15.93 to 76.58±17.00 ms,(p<0.001 at 1week and RV deceleration time (DT from 133.84±38.13 to 153.09±31.41 ms, (p=0.02 at 1 month. Increase in RV internal dimension (RVID from 1.26±0.41 to 1.44±0.44, (p<0.05 was also noticed at 1 week. The LV diastolic parameters were significantly altered after 1 month with increase in LV-IVRT from 92.36±21.47 to 117.24±27.21ms, (p<0.001 and increase in LV DT from 147.56±31.84 to 189.27±28.49ms,(p<0.01. This was followed by LV systolic abnormality which appeared at 6 months with an increase in LVPEP from 100.33±14.43 to 118.41±21.34ms, (p<0.001 and increase in LVPEP/LVET ratio from 0.34±0.46 to 0.44±0.10, (p<0.001]. The reduction in LV EF was manifested at 6 months falling from 61.82±10.36% to52.52±12.11%, (p<0

  8. Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Manolis, Antonis S.; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; de Sousa, João; Botto, Giovanni Luca; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2014-01-01

    Aims Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). Methods and results In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 ± 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55–0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77–1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52–0.85, P MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. ClinicalTrials.gov Identifier NCT00262119. PMID:24771721

  9. Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study.

    Science.gov (United States)

    Siciliano, Mariachiara; Migliore, Federico; Badano, Luigi; Bertaglia, Emanuele; Pedrizzetti, Gianni; Cavedon, Stefano; Zorzi, Alessandro; Corrado, Domenico; Iliceto, Sabino; Muraru, Denisa

    2017-11-01

    To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). In 11 consecutive patients [8 men; median age 65 years (57-75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base-apex direction, up to 90° when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P = 0.02; P = 0.008, respectively) and BiV (P = 0.04; P = 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P = 0.008; P = 0.008; P = 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRT-OFF and BiV (P = 0.002) indicating a systematic increase of longitudinal alignment from the base-apex orientation of the haemodynamic forces. These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis. © Crown copyright 2016.

  10. Tilapia lake virus (TiLV): Literature review

    OpenAIRE

    Jansen, Mona Dverdal; Mohan, Chadag Vishnumurthy

    2017-01-01

    Tilapia lake virus (TiLV) is an emerging infectious agent that has recently been identified in diseased tilapia on three continents. At the time of writing, scientific publications have reported TiLV in samples collected from Colombia, Ecuador, Egypt, Israel and Thailand. While the link between TiLV and disease outbreaks in Israel and Thailand are well documented, further investigations are being undertaken to determine the significance of TiLV in the other countries. Israel and Taiwan Provin...

  11. Application of MV/LV Transformers with OLTC for Increasing the PV Hosting Capacity Of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Heckmann, Wolfram; Geibel, Dominik

    2015-01-01

    The increased use of grid connected photovoltaic (PV) systems in low voltage (LV) grids also raises concern regarding the effects of these new generation units on the grid operation. Overvoltage in LV grids during high PV generation periods is one of the well-known effects caused by PV systems......) and the reactive power absorption by PV inverters, are investigated using field test results and simulations performed on the mentioned LV grid. The results show that the application of OLTC can effectively increase the PV hosting capacity of the grid......., which potentially can decrease the PV hosting capacity of electric grids. This paper presents the applications of medium voltage to low voltage (MV/LV) transformers with on-load tap changers (OLTCs) to prevent overvoltage in high PV penetration conditions. Autonomous methods for controlling...

  12. Broadening of molecular weight distribution of polymers synthesized by metallocene-based dual-site catalysts; Alargamento da distribuicao de massa molar de polimeros sintetizados com catalisadores metalocenicos dual-site

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joao H.Z. dos [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Inst. de Quimica]. E-mail: jhzds@iq.ufrgs.br; Fisch, Adriano G.; Cardozo, Nilo S.M.; Secchi, Argimiro R. [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Dept. de Engenharia Quimica

    2008-07-01

    The main topics related to the use of dual-site catalysts in the production of polymers with broad molecular weight distribution are reviewed. The polymerization using dual-site catalysts is more economical and allows to produce a higher quality product than other processes, such as polymer blend and multistage reactors. However, the formulation of these catalysts is quite complicated since the same catalyst must produce distinct polymer grades. In addition, the release of patents concerning the combination of metallocenes and new technologies for polymerization shows that polymerization processes using dual-site catalysts are of current industrial interest. (author)

  13. Effect of biventricular pacing on heart function evaluated by gated blood pool study in patients with end-stage heart failure

    International Nuclear Information System (INIS)

    Cholewinski, W.; Tarkowska, A.; Stefaniak, B.; Poniatowicz-Frasunek, E.; Kutarski, A.; Oleszczak, K.

    2002-01-01

    Biventricular cardiac pacing has been used as a complementary form of therapy in patients with severe heart failure. The aim of this study was to evaluate the effect of the synchronous stimulation of both ventricles on the heart function measured by gated blood pool study (GBP). Ten patients (9 men and 1 woman aged 53-74 years) with end-stage heart failure (HF) were studied. In all patients long-term biventricular pacing (BV) was applied. The obtained results were compared with single-chamber stimulation in 5 patients and with sinus rhythm (SR) in 8 patients. All patients underwent repeated GBP with RBC labelled with 740 MBq of 99m Tc-pertechnetate. The LVEF was calculated according to the standard method based on the count rates. Phase analysis was performed with the standard method using first Fourier element. Clinically in almost all patients moderate to important symptomatic improvement has been observed. The analysis of LVEF values revealed that BV pacing resulted in significantly higher values only in comparison with SR (21.6% ±10.3 v. 20.1% ± 10.1; p o± 29.6 v. 13.4 o± 37.6 and 7.4 o± 26.5 v. 6.0 o± 17.1, respectively). However, in comparison with LV pacing, BV stimulation revealed a change of dominant conduction abnormalities with a delay of RV contraction in relation to LV (9.0 o± 17.5 v. -3.0 o± 11.4). Biventricular pacing results in slight improvement of LVEF in patients with heart failure and can be considered a promising approach in patients with end-stage heart failure. Synchronous stimulation of both ventricles not always results in decrease of interventricular shift, however that observation requires further studies on a larger population. (author)

  14. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.

    Science.gov (United States)

    Sławuta, Agnieszka; Kliś, Magdalena; Skoczyński, Przemysław; Bańkowski, Tomasz; Moszczyńska-Stulin, Joanna; Gajek, Jacek

    2016-01-01

    Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.

  15. Regulation of FeLV-945 by c-Myb binding and CBP recruitment to the LTR

    Directory of Open Access Journals (Sweden)

    Finstad Samantha L

    2004-09-01

    Full Text Available Abstract Background Feline leukemia virus (FeLV induces degenerative, proliferative and malignant hematologic disorders in its natural host, the domestic cat. FeLV-945 is a viral variant identified as predominant in a cohort of naturally infected animals. FeLV-945 contains a unique sequence motif in the long terminal repeat (LTR comprised of a single copy of transcriptional enhancer followed by a 21-bp sequence triplicated in tandem. The LTR is precisely conserved among independent cases of multicentric lymphoma, myeloproliferative disease and anemia in animals from the cohort. The 21-bp triplication was previously shown to act as a transcriptional enhancer preferentially in hematopoietic cells and to confer a replicative advantage. The objective of the present study was to examine the molecular mechanism by which the 21-bp triplication exerts its influence and the selective advantage responsible for its precise conservation. Results Potential binding sites for the transcription factor, c-Myb, were identified across the repeat junctions of the 21-bp triplication. Such sites would not occur in the absence of the repeat; thus, a requirement for c-Myb binding to the repeat junctions of the triplication would exert a selective pressure to conserve its sequence precisely. Electrophoretic mobility shift assays demonstrated specific binding of c-Myb to the 21-bp triplication. Reporter gene assays showed that the triplication-containing LTR is responsive to c-Myb, and that responsiveness requires the presence of both c-Myb binding sites. Results further indicated that c-Myb in complex with the 21-bp triplication recruits the transcriptional co-activator, CBP, a regulator of normal hematopoiesis. FeLV-945 replication was shown to be positively regulated by CBP in a manner dependent on the presence of the 21-bp triplication. Conclusion Binding sites for c-Myb across the repeat junctions of the 21-bp triplication may account for its precise conservation in

  16. Characterizing Spatial Dynamics of Bifurcation to Alternans in Isolated Whole Rabbit Hearts Based on Alternate Pacing

    Directory of Open Access Journals (Sweden)

    Kanchan Kulkarni

    2015-01-01

    Full Text Available Sudden cardiac death instigated by ventricular fibrillation (VF is the largest cause of natural death in the USA. Alternans, a beat-to-beat alternation in the action potential duration, has been implicated as being proarrhythmic. The onset of alternans is mediated via a bifurcation, which may occur through either a smooth or a border-collision mechanism. The objective of this study was to characterize the mechanism of bifurcation to alternans based on experiments in isolated whole rabbit hearts. High resolution optical mapping was performed and the electrical activity was recorded from the left ventricle (LV epicardial surface of the heart. Each heart was paced using an “alternate pacing protocol,” where the basic cycle length (BCL was alternatively perturbed by ±δ. Local onset of alternans in the heart, BCLstart, was measured in the absence of perturbations (δ=0 and was defined as the BCL at which 10% of LV exhibited alternans. The influences of perturbation size were investigated at two BCLs: one prior to BCLstart (BCLprior=BCLstart+20 ms and one preceding BCLprior (BCLfar=BCLstart+40 ms. Our results demonstrate significant spatial correlation of the region exhibiting alternans with smooth bifurcation characteristics, indicating that transition to alternans in isolated rabbit hearts occurs predominantly through smooth bifurcation.

  17. Effect of chronic right ventricular apical pacing on left ventricular function.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Jones, Philip G; Thompson, Randall C; Bateman, Timothy M; McGhie, A Iain; Ramza, Brian M; Steinhaus, David M

    2005-03-15

    The determinants of change in left ventricular (LV) ejection fraction (EF) over time in patients with impaired LV function at baseline have not been clearly established. Using a nuclear database to assess changes in LV function over time, we included patients with a baseline LVEF of 25% to 40% on a gated single-photon emission computed tomographic study at rest and only if second-gated photon emission computed tomography performed approximately 18 months after the initial study showed an improvement in LVEF at rest of > or =10 points or a decrease in LVEF at rest of > or =7 points. In all, 148 patients qualified for the EF increase group and 59 patients for the EF decrease group. LVEF on average increased from 33 +/- 4% to 51 +/- 8% in the EF increase group and decreased from 35 +/- 4% to 25 +/- 5% in the EF decrease group. The strongest multivariable predictor of improvement of LVEF was beta-blocker therapy (odds ratio 3.9, p = 0.002). The strongest independent predictor of LVEF decrease was the presence of a permanent right ventricular apical pacemaker (odds ratio 6.6, p = 0.002). Thus, this study identified beta-blocker therapy as the major independent predictor for improvement in LVEF of > or =10 points, whereas a permanent pacemaker (right ventricular apical pacing) was the strongest predictor of a LVEF decrease of > or =7 points.

  18. Large animal model of functional tricuspid regurgitation in pacing induced end-stage heart failure.

    Science.gov (United States)

    Malinowski, Marcin; Proudfoot, Alistair G; Langholz, David; Eberhart, Lenora; Brown, Michael; Schubert, Hans; Wodarek, Jeremy; Timek, Tomasz A

    2017-06-01

    Functional tricuspid regurgitation (FTR) is common in patients with advanced heart failure and frequently complicates left ventricular assist device implantation yet remains poorly understood. We set out to establish large animal model of FTR that could serve as a research platform to investigate the pathogenesis of FTR associated with end-stage heart failure. : Through right thoracotomy, ten adult sheep underwent implantation of pacemaker with epicardial LV lead, five sonomicrometry crystals on the right ventricle, and left and right ventricular telemetry pressure sensors during a beating heart off-pump procedure. After 5 ± 1 days of recovery, baseline haemodynamic, echocardiographic and sonomicrometry data were collected. Animals were paced thereafter at a rate of 220-240 beats/min until the development of heart failure and concomitant tricuspid regurgitation. : Three animals died during early recovery period and one during the pacing phase. Six surviving animals were paced for a mean of 14 ± 5 days. Cardiac function was significantly depressed compared to baseline, with LV ejection fraction falling from 69 ± 2% to 22 ± 4% ( P  tricuspid annulus (from 29.5 ± 1.6 to 36.5 ± 4.5 mm; P  = 0.01) and right ventricle (from 21.9 ± 0.2 to 30.3 ± 0.6 mm; P  = 0.03). Sonomicrometry derived contractility of RV free wall was depressed and at least moderate tricuspid insufficiency developed in all animals. : Biventricular dysfunction, tricuspid annular dilatation and significant FTR were observed in our model of ovine tachycardia induced cardiomyopathy. This animal model reflects the clinical situation of end-stage heart failure patients presenting for mechanical support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. A targeted mutation within the feline leukemia virus (FeLV) envelope protein immunosuppressive domain to improve a canarypox virus-vectored FeLV vaccine.

    Science.gov (United States)

    Schlecht-Louf, Géraldine; Mangeney, Marianne; El-Garch, Hanane; Lacombe, Valérie; Poulet, Hervé; Heidmann, Thierry

    2014-01-01

    We previously delineated a highly conserved immunosuppressive (IS) domain within murine and primate retroviral envelope proteins that is critical for virus propagation in vivo. The envelope-mediated immunosuppression was assessed by the ability of the proteins, when expressed by allogeneic tumor cells normally rejected by engrafted mice, to allow these cells to escape, at least transiently, immune rejection. Using this approach, we identified key residues whose mutation (i) specifically abolishes immunosuppressive activity without affecting the "mechanical" function of the envelope protein and (ii) significantly enhances humoral and cellular immune responses elicited against the virus. The objective of this work was to study the immunosuppressive activity of the envelope protein (p15E) of feline leukemia virus (FeLV) and evaluate the effect of its abolition on the efficacy of a vaccine against FeLV. Here we demonstrate that the FeLV envelope protein is immunosuppressive in vivo and that this immunosuppressive activity can be "switched off" by targeted mutation of a specific amino acid. As a result of the introduction of the mutated envelope sequence into a previously well characterized canarypox virus-vectored vaccine (ALVAC-FeLV), the frequency of vaccine-induced FeLV-specific gamma interferon (IFN-γ)-producing cells was increased, whereas conversely, the frequency of vaccine-induced FeLV-specific interleukin-10 (IL-10)-producing cells was reduced. This shift in the IFN-γ/IL-10 response was associated with a higher efficacy of ALVAC-FeLV against FeLV infection. This study demonstrates that FeLV p15E is immunosuppressive in vivo, that the immunosuppressive domain of p15E can modulate the FeLV-specific immune response, and that the efficacy of FeLV vaccines can be enhanced by inhibiting the immunosuppressive activity of the IS domain through an appropriate mutation.

  20. Effects of interventions on normalizing step width during self-paced dual-belt treadmill walking with virtual reality, a randomised controlled trial.

    Science.gov (United States)

    Oude Lansink, I L B; van Kouwenhove, L; Dijkstra, P U; Postema, K; Hijmans, J M

    2017-10-01

    Step width is increased during dual-belt treadmill walking, in self-paced mode with virtual reality. Generally a familiarization period is thought to be necessary to normalize step width. The aim of this randomised study was to analyze the effects of two interventions on step width, to reduce the familiarization period. We used the GRAIL (Gait Real-time Analysis Interactive Lab), a dual-belt treadmill with virtual reality in the self-paced mode. Thirty healthy young adults were randomly allocated to three groups and asked to walk at their preferred speed for 5min. In the first session, the control-group received no intervention, the 'walk-on-the-line'-group was instructed to walk on a line, projected on the between-belt gap of the treadmill and the feedback-group received feedback about their current step width and were asked to reduce it. Interventions started after 1min and lasted 1min. During the second session, 7-10days later, no interventions were given. Linear mixed modeling showed that interventions did not have an effect on step width after the intervention period in session 1. Initial step width (second 30s) of session 1 was larger than initial step width of session 2. Step width normalized after 2min and variation in step width stabilized after 1min. Interventions do not reduce step width after intervention period. A 2-min familiarization period is sufficient to normalize and stabilize step width, in healthy young adults, regardless of interventions. A standardized intervention to normalize step width is not necessary. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Fully automated segmentation of left ventricle using dual dynamic programming in cardiac cine MR images

    Science.gov (United States)

    Jiang, Luan; Ling, Shan; Li, Qiang

    2016-03-01

    Cardiovascular diseases are becoming a leading cause of death all over the world. The cardiac function could be evaluated by global and regional parameters of left ventricle (LV) of the heart. The purpose of this study is to develop and evaluate a fully automated scheme for segmentation of LV in short axis cardiac cine MR images. Our fully automated method consists of three major steps, i.e., LV localization, LV segmentation at end-diastolic phase, and LV segmentation propagation to the other phases. First, the maximum intensity projection image along the time phases of the midventricular slice, located at the center of the image, was calculated to locate the region of interest of LV. Based on the mean intensity of the roughly segmented blood pool in the midventricular slice at each phase, end-diastolic (ED) and end-systolic (ES) phases were determined. Second, the endocardial and epicardial boundaries of LV of each slice at ED phase were synchronously delineated by use of a dual dynamic programming technique. The external costs of the endocardial and epicardial boundaries were defined with the gradient values obtained from the original and enhanced images, respectively. Finally, with the advantages of the continuity of the boundaries of LV across adjacent phases, we propagated the LV segmentation from the ED phase to the other phases by use of dual dynamic programming technique. The preliminary results on 9 clinical cardiac cine MR cases show that the proposed method can obtain accurate segmentation of LV based on subjective evaluation.

  2. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.; Amidan, Brett G.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

  3. Current distribution in LV networks during 1-phase MV short-circuit

    NARCIS (Netherlands)

    Waes, van J.B.M.; Provoost, F.; Merwe, van der J.; Cobben, J.F.G.; Deursen, van A.P.J.; van Riet, M.J.M.; Laan, van der P.C.T.

    2000-01-01

    This paper describes the consequences of a fault in a medium voltage network on the grounding systems at the LV-side. To study the current distribution and to verify the models, we deliberately introduced one phase to ground faults in the 10 kV floating MV network. The selected site was the end of a

  4. E/e' Ratio: An Index of LV Filling Pressures Revisited

    Directory of Open Access Journals (Sweden)

    Sherif F. Nagueh

    2013-01-01

    Full Text Available There is a clinical need for the assessment of cardiac function in patients who present with symptoms and signs of pulmonary and systemic congestion. Echocardiography has been utilized over the years to answer this question. It is possible to study left ventricular (LV systolic and diastolic function as well as pulmonary artery pressures and right ventricular function using this technique. With respect to LV diastolic function, an ideal assessment includes evaluation of LV relaxation and LV filling pressures. There are several parameters that when properly acquired and analyzed can predict the 2 fundamental aspects noted above of LV diastolic function. The mitral annulus early diastolic recoil velocity (e’ recorded by tissue Doppler imaging (TDI was introduced as an index of LV relaxation. Further, e’ velocity is combined with mitral peak velocity E to predict LV filling pressures1. I will discuss the supporting literature for the last statement and point to the limitations in its application.

  5. Effects of Cardiac Resynchronization Therapy on the Arrhythmic Substrate in a Patient with Long QT and Torsades de pointes

    Directory of Open Access Journals (Sweden)

    Masayasu Ikutomi, MD

    2011-01-01

    Full Text Available We describe a patient with torsades de pointes (TdP who was implanted with cardiac resynchronization therapy defibrillator (CRT-D. At the time of CRT-D implantation, left ventricular (LV epicardial pacing exacerbated TdPs and developed into electrical storm, which was triggered even by biventricular pacing. We needed to inactivate the LV lead for 2 weeks. At the next device check testing of LV pacing still induced TdPs, whe reas biventricular pacing did not. After starting the continuous biventricular pacing no ventricular arrhythmias happened, and furthermore the QT intervals prolonged by LV pacing were obviously shortened only after 2 weeks as ventricular systolic function recovered. Then even continuous LV alone pacing induced no TdP. These findings indicate novel electrical effects of cardiac resynchronization therapy.

  6. The Use of a Quadripolar Left Ventricular Lead Increases Successful Implantation Rates in Patients with Phrenic Nerve Stimulation and/or High Pacing Thresholds Undergoing Cardiac Resynchronisation Therapy with Conventional Bipolar Leads

    Directory of Open Access Journals (Sweden)

    Marc-Alexander Ohlow, MD

    2013-03-01

    Conclusions: Excessively HPT and/or PNS are frequently encountered when conventional bipolar leads are used for CRT. A new quadripolar LV lead increases the rate of successful biventricular stimulation. Lower pacing threshold and freedom from PNS are maintained at follow-up.

  7. Comparative Efficacy of Feline Leukemia Virus (FeLV) Inactivated Whole-Virus Vaccine and Canarypox Virus-Vectored Vaccine during Virulent FeLV Challenge and Immunosuppression.

    Science.gov (United States)

    Patel, M; Carritt, K; Lane, J; Jayappa, H; Stahl, M; Bourgeois, M

    2015-07-01

    Four vaccines for feline leukemia virus (FeLV) are available in the United States. This study's purpose was to compare the efficacy of Nobivac feline 2-FeLV (an inactivated, adjuvanted whole-virus vaccine) and PureVax recombinant FeLV (a live, canarypox virus-vectored vaccine) following FeLV challenge. Cats were vaccinated at 9 and 12 weeks with Nobivac feline 2-FeLV (group A, n = 11) or PureVax recombinant FeLV (group B, n = 10). Group C (n = 11) comprised unvaccinated controls. At 3 months postvaccination, cats were immunosuppressed and challenged with FeLV-A/61E. The outcomes measured were persistent antigenemia at 12 weeks postchallenge (PC) and proviral DNA and viral RNA at 3 to 9 weeks PC. Persistent antigenemia was observed in 0 of 11 cats in group A, 5 of 10 cats in group B, and 10 of 11 cats in group C. Group A was significantly protected compared to those in groups B (P 0.063). The preventable fraction was 100% for group A and 45% for group B. At 9 weeks PC, proviral DNA and viral RNA were detected 1 of 11 cats in group A, 6 of 10 cats in group B, and 9 of 11 cats in group C. Nucleic acid loads were significantly lower in group A than in group C (P feline 2-FeLV-vaccinated cats were fully protected against persistent antigenemia and had significantly smaller amounts of proviral DNA and plasma viral RNA loads than PureVax recombinant FeLV-vaccinated cats and unvaccinated controls. Copyright © 2015, Patel et al.

  8. Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing

    DEFF Research Database (Denmark)

    Riahi, Sam; Nielsen, Jens Cosedis; Hjortshøj, Søren

    2012-01-01

    AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular...... patients (17%) with the leads in a non-apical position, HR 0.67, CI 0.45-1.00, P = 0.05. After adjustments this difference was non-significant. The incidence of HF was not associated with %VP (P = 0.57).CONCLUSION: In patients with SSS, HF was not associated with pacing mode, %VP, or ventricular lead...... localization. This suggests that DDDR pacing is safe in patients with SSS without precipitating HF....

  9. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  10. Effective RNA-silencing strategy of Lv-MSTN/GDF11 gene and its effects on the growth in shrimp, Litopenaeus vannamei.

    Science.gov (United States)

    Lee, Ji-Hyun; Momani, Jalal; Kim, Young Mog; Kang, Chang-Keun; Choi, Jung-Hwa; Baek, Hae-Ja; Kim, Hyun-Woo

    2015-01-01

    Myostatin (MSTN), also known as GDF8, is a member of the transforming growth factor-β (TGF-β) superfamily and plays an important role in muscle growth, development, and differentiation. Recently, Lv-MSTN/GDF11, the primitive isoform of MSTN and GDF11, was identified from the shrimp Litopenaeus vannamei. The major production site for Lv-MSTN/GDF11 is in the heart, not the tail muscle, which differs from MSTNs in mammals. Among the three injected RNAs, long dsRNA was the most effective for Lv-MSTN/GDF11 knockdown and transcripts of Lv-MSTN/GDF11 decreased in both the heart (88.85%) and skeletal muscles (43.36%) 72h after injection of 10pmol of long dsRNA. We also found that higher doses of dsRNA did not lead to greater decreases in Lv-MSTN/GDF11 transcripts for amounts between 1pmol and 100pmol. Injection of Lv-MSTN/GDF11 dsRNA did not affect the upregulation of the skeletal actin gene (Lv-ACTINSK) in the tail muscle, but the expression of cytoplasmic and cardiac actins were upregulated in both the heart and tail muscle. Over the course of 8weeks of dsRNA injection, considerably higher mortality (~71%) was seen in the dsRNA-injected group compared to the control group (40%). Surviving shrimp in the dsRNA injected group had a lower growth rate due to the adverse effects of Lv-MSTN/GDF11 knockdown. Lv-MSTN/GDF11 appears to be involved in muscular or neuronal development, but not in doubling muscle fibers, as is the case with mammalian MSTN. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Diagnostic accuracy of pace spikes in the electrocardiogram to diagnose paced rhythm

    DEFF Research Database (Denmark)

    Andersson, Hedvig Bille; Hansen, Marco Bo; Thorsberger, Mads

    2015-01-01

    OBJECTIVE: To determine how often cardiac resynchronization therapy (CRT) pacing systems generate visible pace spikes in the electrocardiogram (ECG). METHODS: In 46 patients treated with CRT pacing systems, we recorded ECGs during intrinsic rhythm, atrial pacing and ventricular pacing. ECGs were...

  12. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    Science.gov (United States)

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  13. Effect of Smaller Left Ventricular Capture Threshold Safety Margins to Improve Device Longevity in Recipients of Cardiac Resynchronization-Defibrillation Therapy.

    Science.gov (United States)

    Steinhaus, Daniel A; Waks, Jonathan W; Collins, Robert; Kleckner, Karen; Kramer, Daniel B; Zimetbaum, Peter J

    2015-07-01

    Device longevity in cardiac resynchronization therapy (CRT) is affected by the pacing capture threshold (PCT) and programmed pacing amplitude of the left ventricular (LV) pacing lead. The aims of this study were to evaluate the stability of LV pacing thresholds in a nationwide sample of CRT defibrillator recipients and to determine potential longevity improvements associated with a decrease in the LV safety margin while maintaining effective delivery of CRT. CRT defibrillator patients in the Medtronic CareLink database were eligible for inclusion. LV PCT stability was evaluated using ≥2 measurements over a 14-day period. Separately, a random sample of 7,250 patients with programmed right atrial and right ventricular amplitudes ≤2.5 V, LV thresholds ≤ 2.5 V, and LV pacing ≥90% were evaluated to estimate theoretical battery longevity improvement using LV safety margins of 0.5 and 1.5 V. Threshold stability analysis in 43,256 patients demonstrated LV PCT stability of 1 V had the greatest increases in battery life (mean increase 0.86 years, 95% confidence interval 0.85 to 0.87). In conclusion, nearly all CRT defibrillator patients had LV PCT stability <1.0 V. Decreasing the LV safety margin from 1.5 to 0.5 V provided consistent delivery of CRT for most patients and significantly improved battery longevity. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Studies on the synthesis of isotopes of superheavy element Lv (Z = 116)

    Energy Technology Data Exchange (ETDEWEB)

    Santhosh, K.P.; Safoora, V. [Kannur University, School of Pure and Applied Physics, Payyanur (India)

    2017-11-15

    The probable projectile-target combinations for the synthesis of superheavy nucleus {sup 296}Lv found in the cold valley of {sup 296}Lv have been identified by studying the interaction barrier of the colliding nuclei, probability of compound nucleus formation, P{sub CN}, and survival probability W{sub sur}. At energies near and above the Coulomb barrier, the capture, fusion and evaporation residue (ER) cross sections for the probable combinations for the hot and cold fusion reactions are systematically investigated. By considering intensities of the projectile beams, availabilities of the targets and half lives of the colliding nuclei, the combination {sup 48}Ca + {sup 248}Cm is found to be the most probable projectile-target pair for the synthesis of {sup 296}Lv. The calculated maximum value of 2n, 3n, 4n and 5n channel cross section for the reaction {sup 48}Ca + {sup 248}Cm are 0.599 pb, 5.957 pb, 4.805 pb, and 0.065 pb, respectively. Moreover, the production cross sections for the synthesis of isotopes {sup 291-295,298}Lv using {sup 48}Ca projectile on {sup 243-247,250}Cm targets are calculated. Among these reactions, the reactions {sup 48}Ca + {sup 247}Cm → {sup 295}Lv and {sup 48}Ca + {sup 250}Cm → {sup 298}Lv have maximum production cross section in 3n (10.697 pb) and 4n (12.006 pb) channel, respectively. Our studies on the SHE Lv using the combinations {sup 48}Ca + {sup 245}Cm → {sup 293}Lv and {sup 48}Ca + {sup 248}Cm → {sup 296}Lv are compared with available experimental data and with other theoretical studies. Our studies are in agreement with experimental data and we hope that these studies will be a guide for the future experiments to synthesize the isotopes of Lv. (orig.)

  15. Altering Pace Control and Pace Regulation: Attentional Focus Effects during Running.

    Science.gov (United States)

    Brick, Noel E; Campbell, Mark J; Metcalfe, Richard S; Mair, Jacqueline L; Macintyre, Tadhg E

    2016-05-01

    To date, there are no published studies directly comparing self-controlled (SC) and externally controlled (EC) pace endurance tasks. However, previous research suggests pace control may impact on cognitive strategy use and effort perceptions. The primary aim of this study was to investigate the effects of manipulating perception of pace control on attentional focus, physiological, and psychological outcomes during running. The secondary aim was to determine the reproducibility of self-paced running performance when regulated by effort perceptions. Twenty experienced endurance runners completed four 3-km time trials on a treadmill. Subjects completed two SC pace trials, one perceived exertion clamped (PE) trial, and one EC pace time trial. PE and EC were completed in a counterbalanced order. Pacing strategy for EC and perceived exertion instructions for PE replicated the subjects' fastest SC time trial. Subjects reported a greater focus on cognitive strategies such as relaxing and optimizing running action during EC than during SC. The mean HR was 2% lower during EC than that during SC despite an identical pacing strategy. Perceived exertion did not differ between the three conditions. However, increased internal sensory monitoring coincided with elevated effort perceptions in some subjects during EC and a 10% slower completion time for PE (13.0 ± 1.6 min) than that for SC (11.8 ± 1.2 min). Altering pace control and pace regulation impacted on attentional focus. External control over pacing may facilitate performance, particularly when runners engage attentional strategies conducive to improved running efficiency. However, regulating pace based on effort perceptions alone may result in excessive monitoring of bodily sensations and a slower running speed. Accordingly, attentional focus interventions may prove beneficial for some athletes to adopt task-appropriate attentional strategies to optimize performance.

  16. Presentation Time Concerning System-Paced Multimedia Instructions and the Superiority of Learner Pacing

    Science.gov (United States)

    Stiller, Klaus D.; Petzold, Kirstin; Zinnbauer, Peter

    2011-01-01

    The superiority of learner-paced over system-paced instructions was demonstrated in multiple experiments. In these experiments, the system-paced presentations were highly speeded, causing cognitive overload, while the learner-paced instructions allowed adjustments of the presentational flow to the learner's needs by pacing facilities, mostly…

  17. Site-selective three-component reaction for dual-functionalization of peptides

    DEFF Research Database (Denmark)

    Munch, Henrik Kofoed; Rasmussen, Jakob Ewald; Popa, Gina

    2013-01-01

    A site-selective dual-functionalization of peptides is presented, involving readily available maleimides as well as N-hydroxylamines. The modification proceeds through a three component 1,3-dipolar cycloaddition, forming a stable product. This was exemplified by the one-pot attachment of two...

  18. Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Casavant, David; Betzold, Robert; Sheldon, Todd; Tang, Feng; Mueller, Megan; Lingle, John

    2005-08-01

    Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.

  19. Seismic monitoring during acid stimulation of wells LV-4 and LV-13 at the Las Tres Virgenes geothermal field, BCS, Mexico; Monitoreo sismico durante la estimulacion acida de los pozos LV-4 y LV-13 del campo geotermico de Las Tres Virgenes, BCS, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Venegas Salgado, Saul; Arredondo Fragoso, Jesus; Ramirez Silva, German; Flores Armenta, Magaly; Ramirez Montes, Miguel [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)]. E-mail: magaly.flores@cfe.gob.mx

    2006-07-15

    From September through December 2004 a seismic monitoring in the Las Tres Virgenes, BCS, geothermal field was carried out simultaneously with the acid stimulation of wells LV-4 and LV-13. The seismic network had four digital seismographs and recorded 174 local seismic events, 131 regional ones and many more volcanic signals at seismic station TV20 during the acid stimulation. Additionally, 37 seismic events were located, 22 of them inside the most important geothermal zone at depths between 0.4 and 4 km with typically low magnitudes (0.7 to 2.2 Md). Two relevant zones were determined: Zone A related to the El Volcan fault system and Zone B related to injection well LV-8. In Zone A the well-induction stage and the operation start of the wells LV-4 and LV-13 after acidification on October 30 and November 17, 2004, increased seismic activity to a maximum of 12 daily events in early December. When the two wells in Zone B were cooled before the acidification, the seismic events recorded there increased to a maximum of 6 daily events on October 2, and then decreased. Also in Zone B the seismic activity increased after well-induction and the start of well production once they were acidified, recording up to 11 daily events in late November. According to the seismic distribution, we may conclude that the most active fault systems are El Volcan and El Viejo. New proposals for well locations in the field are supported by these results. [Spanish] De septiembre a diciembre de 2004 se realizo un estudio de monitoreo sismico en el campo geotermico de Las Tres Virgenes, BCS, simultaneamente con las estimulaciones acidas de los pozos LV-4 y LV-13. Se utilizo una red sismica conformada por cuatro sismografos digitales, logrando registrar en la estacion sismica TV20 un total de 174 sismos locales, 131 sismos regionales y muchas mas senales de tipo volcanico, durante el periodo del monitoreo de la estimulacion acida. Ademas, se localizaron un total de 37 sismos, de los cuales 22 se

  20. Effect of dual-chamber minimal ventricular pacing on paroxysmal atrial fibrillation incidence in myotonic dystrophy type 1 patients: A prospective, randomized, single-blind, crossover study.

    Science.gov (United States)

    Russo, Vincenzo; Papa, Andrea Antonio; Rago, Anna; Ciardiello, Carmine; Nigro, Gerardo

    2018-03-08

    Atrial fibrillation (AF) is a common finding in the myotonic dystrophy type 1 (DM1) population. Pacemakers (PMs) may facilitate the diagnosis and management of frequent subclinical asymptomatic AF episodes. The purpose of this study was to evaluate the effect of minimal ventricular pacing on paroxysmal AF incidence in DM1 patients during a 24-month follow-up period. We enrolled 70 DM1 patients (age 43.4 ± 13.8 years; 39 women) who underwent dual-chamber PM implantation. Patients were randomized to minimizing ventricular pacing features (ON) or not (OFF). Patients crossed over to the opposite pacing programming 12 months later. We counted the number of DM1 patients with at least 1 episode of AF, the AF total duration, and the burden recorded by PM diagnostics during the MVP ON and OFF phases. Twenty-five DM1 patients (41.7%) showed at least 1 AF episode. Seven patients (11.7%) demonstrated AF episodes during MVP ON phase and 25 patients (41.7%) during MVP OFF phase (P MVP ON or OFF phase, 3 patients had AF episodes only during MVP ON phase, 21 patients had AF episodes only during MVP OFF phase, and 4 patients had AF episodes during MVP ON and OFF phases. Activation of the MVP algorithm was associated with a 44% reduction in relative risk of developing AF. Furthermore, during the MVP ON phases, the study population showed a shorter total AF duration and a lower AF burden. MVP is an efficacy strategy for reducing the risk of AF in DM1 patients who have undergone PM implantation. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Localization of endocardial ectopic activity by means of noninvasive endocardial surface current density reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Lai Dakun; Liu Chenguang; Eggen, Michael D; He Bin [Department of Biomedical Engineering, University of Minnesota, MN (United States); Iaizzo, Paul A, E-mail: binhe@umn.edu [Department of Surgery, University of Minnesota, MN (United States)

    2011-07-07

    Localization of the source of cardiac ectopic activity has direct clinical benefits for determining the location of the corresponding ectopic focus. In this study, a recently developed current-density (CD)-based localization approach was experimentally evaluated in noninvasively localizing the origin of the cardiac ectopic activity from body-surface potential maps (BSPMs) in a well-controlled experimental setting. The cardiac ectopic activities were induced in four well-controlled intact pigs by single-site pacing at various sites within the left ventricle (LV). In each pacing study, the origin of the induced ectopic activity was localized by reconstructing the CD distribution on the endocardial surface of the LV from the measured BSPMs and compared with the estimated single moving dipole (SMD) solution and precise pacing site (PS). Over the 60 analyzed beats corresponding to ten pacing sites (six for each), the mean and standard deviation of the distance between the locations of maximum CD value and the corresponding PSs were 16.9 mm and 4.6 mm, respectively. In comparison, the averaged distance between the SMD locations and the corresponding PSs was slightly larger (18.4 {+-} 3.4 mm). The obtained CD distribution of activated sources extending from the stimulus site also showed high consistency with the endocardial potential maps estimated by a minimally invasive endocardial mapping system. The present experimental results suggest that the CD method is able to locate the approximate site of the origin of a cardiac ectopic activity, and that the distribution of the CD can portray the propagation of early activation of an ectopic beat.

  2. Atrial antitachycardia pacing and atrial remodeling: A substudy of the international, randomized MINERVA trial.

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Biffi, Mauro; Mont, Lluis; Ricci, Renato; Pürerfellner, Helmut; Botto, Giovanni Luca; Manolis, Antonis S; Landolina, Maurizio; Gulizia, Michele; Hudnall, J Harrison; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2017-10-01

    Atrial tachycardia (AT) and atrial fibrillation (AF) are common in pacemaker patients and are associated with bad prognoses. The purpose of this study was to evaluate atrial antitachycardia pacing impact on AT/AF-induced atrial remodeling, measured by early recurrence of AT/AF (ERAF) and by change in left atrial diameter (LAD), and to evaluate the impact of AT/AF duration on ERAF incidence. Pacemaker patients were randomized to dual-chamber pacing (Control DDDR: 385 patients), managed ventricular pacing (MVP: 398 patients), or atrial antitachycardia pacing plus MVP (DDDRP+MVP: 383 patients). LAD change, estimated by echocardiography, was considered significant if the relative difference between baseline and 24-month measurements was >10%. At median follow-up of 34 months, ERAF incidence was significantly lower in the DDDRP+MVP arm for all AT/AF durations, in particular, ERAF followed AT/AF longer than 3 hours in 53% cases in Control DDDR, in 51% cases in MVP, and in 39% cases in DDDRP+MVP (P MVP, and 70% in DDDRP+MVP (P MVP, DDDRP+MVP reduces ERAF and favors LAD reduction, suggesting that atrial antitachycardia pacing may reverse electrical and mechanical remodeling. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Breath pacing system and method for pacing the respiratory activity of a subject

    NARCIS (Netherlands)

    2016-01-01

    To provide a breath pacing system and a corresponding method for pacing the respiratory activity of a subject that provide the possibility to adapt the output signal to the respiration characteristics of the subject automatically and effectively a breath pacing system (10) for pacing the respiratory

  4. Inferring microbial interaction networks from metagenomic data using SgLV-EKF algorithm.

    Science.gov (United States)

    Alshawaqfeh, Mustafa; Serpedin, Erchin; Younes, Ahmad Bani

    2017-03-27

    Inferring the microbial interaction networks (MINs) and modeling their dynamics are critical in understanding the mechanisms of the bacterial ecosystem and designing antibiotic and/or probiotic therapies. Recently, several approaches were proposed to infer MINs using the generalized Lotka-Volterra (gLV) model. Main drawbacks of these models include the fact that these models only consider the measurement noise without taking into consideration the uncertainties in the underlying dynamics. Furthermore, inferring the MIN is characterized by the limited number of observations and nonlinearity in the regulatory mechanisms. Therefore, novel estimation techniques are needed to address these challenges. This work proposes SgLV-EKF: a stochastic gLV model that adopts the extended Kalman filter (EKF) algorithm to model the MIN dynamics. In particular, SgLV-EKF employs a stochastic modeling of the MIN by adding a noise term to the dynamical model to compensate for modeling uncertainties. This stochastic modeling is more realistic than the conventional gLV model which assumes that the MIN dynamics are perfectly governed by the gLV equations. After specifying the stochastic model structure, we propose the EKF to estimate the MIN. SgLV-EKF was compared with two similarity-based algorithms, one algorithm from the integral-based family and two regression-based algorithms, in terms of the achieved performance on two synthetic data-sets and two real data-sets. The first data-set models the randomness in measurement data, whereas, the second data-set incorporates uncertainties in the underlying dynamics. The real data-sets are provided by a recent study pertaining to an antibiotic-mediated Clostridium difficile infection. The experimental results demonstrate that SgLV-EKF outperforms the alternative methods in terms of robustness to measurement noise, modeling errors, and tracking the dynamics of the MIN. Performance analysis demonstrates that the proposed SgLV-EKF algorithm

  5. Interatrial septum versus right atrial appendage pacing for prevention of atrial fibrillation : A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Zhang, L; Jiang, H; Wang, W; Bai, J; Liang, Y; Su, Y; Ge, J

    2017-07-28

    Interatrial septum (IAS) pacing seems to be a promising strategy for the prevention of atrial fibrillation (AF); however, studies have yielded conflicting results. This meta-analysis was to compare IAS with right atrial appendage (RAA) pacing on the prevention of postpacing AF occurrence. Pubmed, MEDLINE, EMBASE and Web of Science databases were searched through October 2016 for randomized controlled trials comparing IAS with RAA pacing on the prevention of AF. Data concerning study design, patient characteristics and outcomes were extracted. Risk ratio (RR), weighted mean differences (WMD) or standardized mean differences (SMD) were calculated using fixed or random effects models. A total of 12 trials involving 1146 patients with dual-chamber pacing were included. Although IAS was superior to RAA pacing in terms of reducing the number of AF episodes (SMD = -0.29, P = 0.05), AF burden (SMD = -0.41, P = 0.008) and P -wave duration (WMD = -34.45 ms, P IAS pacing. Nevertheless, no differences were observed concerning all-cause death (RR = 1.04, P = 0.88), procedure-related events (RR = 1.17, P = 0.69) and pacing parameters between IAS and RAA pacing in the follow-up period. IAS pacing is safe and as well tolerated as RAA pacing. Although IAS pacing may fail to prevent permanent AF occurrence and recurrences of AF, it is able to not only improve interatrial conduction, but also reduce AF burden.

  6. Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay.

    Science.gov (United States)

    Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian

    2018-02-06

    QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. Interatrial septum pacing decreases atrial dyssynchrony on strain rate imaging compared with right atrial appendage pacing.

    Science.gov (United States)

    Yasuoka, Yoshinori; Abe, Haruhiko; Umekawa, Seiko; Katsuki, Keiko; Tanaka, Norio; Araki, Ryo; Imanaka, Takahiro; Matsutera, Ryo; Morisawa, Daisuke; Kitada, Hirokazu; Hattori, Susumu; Noda, Yoshiki; Adachi, Hidenori; Sasaki, Tatsuya; Miyatake, Kunio

    2011-03-01

    Interatrial septum pacing (IAS-P) decreases atrial conduction delay compared with right atrial appendage pacing (RAA-P). We evaluate the atrial contraction with strain rate of tissue Doppler imaging (TDI) during sinus activation or with IAS-P or RAA-P. Fifty-two patients with permanent pacemaker for sinus node disease were enrolled in the study. Twenty-three subjects were with IAS-P and 29 with RAA-P. The time from end-diastole to peak end-diastolic strain rate was measured and corrected with RR interval on electrocardiogram. It was defined as the time from end-diastole to peak end-diastolic strain rate (TSRc), and the balance between maximum and minimum TSRc at three sites (ΔTSRc) was compared during sinus activation and with pacing rhythm in each group. There were no significant differences observed in general characteristics and standard echocardiographic parameters except the duration of pacing P wave between the two groups. The duration was significantly shorter in the IAS-P group compared with the RAA-P group (95 ± 34 vs 138 ± 41; P = 0.001). TSRc was significantly different between sinus activation and pacing rhythm (36.3 ± 35.7 vs 61.6 ± 36.3; P = 0.003) in the RAA-P group, whereas no significant differences were observed in the IAS-P group (25.4 ± 12.1 vs 27.7 ± 14.7; NS). During the follow-up (mean 2.4 ± 0.7 years), the incidence of paroxysmal atrial fibrillation (AF) conversion to permanent AF was not significantly different between the two groups. IAS-P decreased the contraction delay on atrial TDI compared to RAA-P; however, it did not contribute to the reduction of AF incidence in the present study. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  8. Mast cell stabilization decreases cardiomyocyte and LV function in dogs with isolated mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Killingsworth, Cheryl; Chen, Yuanwen; Gladden, James D; Walcott, Greg; Powell, Pamela C; Denney, Thomas; Gupta, Himanshu; Desai, Ravi; Tillson, Michael; Dillon, A Ray; Dell'italia, Louis J

    2010-09-01

    Mast cells are increased in isolated mitral regurgitation (MR) in the dog and may mediate extracellular matrix loss and left ventricular (LV) dilatation. We tested the hypothesis that mast cell stabilization would attenuate LV remodeling and improve function in the MR dog. MR was induced in adult dogs randomized to no treatment (MR, n = 5) or to the mast cell stabilizer, ketotifen (MR + MCS, n = 4) for 4 months. LV hemodynamics were obtained at baseline and after 4 months of MR and magnetic resonance imaging (MRI) was performed at sacrifice. MRI-derived, serial, short-axis LV end-diastolic (ED) and end-systolic (ES) volumes, LVED volume/mass ratio, and LV 3-dimensional radius/wall thickness were increased in MR and MR + MCS dogs compared with normal dogs (n = 6) (P < .05). Interstitial collagen was decreased by 30% in both MR and MR + MCS versus normal dogs (P < .05). LV contractility by LV maximum time-varying elastance was significantly depressed in MR and MR + MCS dogs. Furthermore, cardiomyocyte fractional shortening was decreased in MR versus normal dogs and further depressed in MR + MCS dogs (P < .05). In vitro administration of ketotifen to normal cardiomyocytes also significantly decreased fractional shortening and calcium transients. Chronic mast cell stabilization did not attenuate eccentric LV remodeling or collagen loss in MR. However, MCS therapy had a detrimental effect on LV function because of a direct negative inotropic effect on cardiomyocyte function. Published by Elsevier Inc.

  9. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators.

    Science.gov (United States)

    Michael, Kevin A; Enriquez, Andres; Baranchuk, Adrian; Haley, Charlotte; Caldwell, Jane; Simpson, Christopher S; Abdollah, Hoshiar; Redfearn, Damian P

    2015-01-01

    Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  10. Specification of requirements to get a license for an Independent Spent Fuel Dry Storage Installation (ISFSI) at the site of the NPP-LV

    International Nuclear Information System (INIS)

    Serrano R, M. L.

    2015-09-01

    This article describes some of the work done in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) to define specifically the requirements that the Federal Electricity Commission (CFE) shall meet to submit for consideration of CNSNS an operation request of an Independent Spent Fuel Dry Storage Installation (ISFSI). The project of a facility of this type arose from the need to provide storage capacity for spent nuclear fuel in the nuclear power plant of Laguna Verde (NPP-LV) and to continue the operation at the same facility in a safe manner. The licensing of these facilities in the United States of America has two modes: specific license or general license. The characteristics of these licenses are described in this article. However, in Mexico the existing national legislation is not designed for such license types, in fact there is a lack of standards or regulations in this regard. The regulatory law of Article 27 of the Constitution in the nuclear matter, only generally establishes that this type of facility requires an authorization from the Ministry of Energy. For this reason and because there is not a national legislation, was necessary to use the legislation that provides the Nuclear Regulatory Commission of USA, the US NRC. However, it cannot be applied as is established, so was necessary that the CNSNS analyze one by one the requirements of both types of license and determine what would be required to NPP-LV to submit its operating license of ISFSI. The American regulatory applicable to an ISFSI, the 10-Cfr-72 of the US NRC, establishes the requirements for both types of licenses. Chapter 10-Cfr was analyzed in all its clauses and coupled to the laws, regulations and standards as well as to the requirements established by CNSNS, all associated with a store spent fuel on site; the respective certification of containers for spent fuel dry storage was not included in this article, even though the CNSNS also performed that activity under the

  11. Orthogonal electrode catheter array for mapping of endocardial focal site of ventricular activation

    Energy Technology Data Exchange (ETDEWEB)

    Desai, J.M.; Nyo, H.; Vera, Z.; Seibert, J.A.; Vogelsang, P.J. (Division of Cardiovascular Medicine, University of California, School of Medicine, Davis (USA))

    1991-04-01

    Precise location of the endocardial site of origin of ventricular tachycardia may facilitate surgical and catheter ablation of this arrhythmia. The endocardial catheter mapping technique can locate the site of ventricular tachycardia within 4-8 cm2 of the earliest site recorded by the catheter. This report describes an orthogonal electrode catheter array (OECA) for mapping and radiofrequency ablation (RFA) of endocardial focal site of origin of a plunge electrode paced model of ventricular activation in dogs. The OECA is an 8 F five pole catheter with four peripheral electrodes and one central electrode (total surface area 0.8 cm{sup 2}). In eight mongrel dogs, mapping was performed by arbitrarily dividing the left ventricle (LV) into four segments. Each segment was mapped with OECA to find the earliest segment. Bipolar and unipolar electrograms were obtained. The plunge electrode (not visible on fluoroscopy) site was identified by the earliest wave front arrival times of -30 msec or earlier at two or more electrodes (unipolar electrograms) with reference to the earliest recorded surface ECG (I, AVF, and V1). Validation of the proximity of the five electrodes of the OECA to the plunge electrode was performed by digital radiography and RFA. Pathological examination was performed to document the proximity of the OECA to the plunge electrode and also for the width, depth, and microscopic changes of the ablation. To find the segment with the earliest LV activation a total of 10 {plus minus} 3 (mean {plus minus} SD) positions were mapped. Mean arrival times at the two earlier electrodes were -39 {plus minus} 4 msec and -35 {plus minus} 3 msec. Digital radiography showed the plunge electrode to be within the area covered by all five electrodes in all eight dogs. The plunge electrode was within 1 cm2 area of the region of RFA in all eight dogs.

  12. Integration of SPICE with TEK LV500 ASIC Design Verification System

    Directory of Open Access Journals (Sweden)

    A. Srivastava

    1996-01-01

    Full Text Available The present work involves integration of the simulation stage of design of a VLSI circuit and its testing stage. The SPICE simulator, TEK LV500 ASIC Design Verification System, and TekWaves, a test program generator for LV500, were integrated. A software interface in ‘C’ language in UNIX ‘solaris 1.x’ environment has been developed between SPICE and the testing tools (TekWAVES and LV500. The function of the software interface developed is multifold. It takes input from either SPICE2G.6 or SPICE 3e.1. The output generated by the interface software can be given as an input to either TekWAVES or LV500. A graphical user interface has also been developed with OPENWlNDOWS using Xview tool kit on SUN workstation. As an example, a two phase clock generator circuit has been considered and usefulness of the software demonstrated. The interface software could be easily linked with VLSI design such as MAGIC layout editor.

  13. Correlation between the sudden jump-like increases of the atrio-Hisian interval induced during burst atrial pacing and during programmed atrial stimulation in patients with atrioventricular nodal reentrant tachycardia.

    Science.gov (United States)

    Bayraktarova, Iskra H; Stoyanov, Milko K; Kunev, Boyan T; Shalganov, Tchavdar N

    To study the correlation between the sudden prolongations of the atrio-Hisian (AH) interval with ≥50 ms during burst and programmed atrial stimulation, and to define whether the AH jump during burst atrial pacing is a reliable diagnostic criterion for dual AV nodal physiology. Retrospective data on 304 patients with preliminary ECG diagnosis of AV nodal reentrant tachycardia (AVNRT), confirmed during electrophysiological study, was analyzed for the presence of AH jump during burst and programmed atrial stimulation, and for correlation between the pacing modes for inducing the jump. Wilcoxon signed-ranks test and Spearman's bivariate correlation coefficient were applied, significant was P-value jump occurred during burst atrial pacing in 81% of the patients, and during programmed stimulation - in 78%, P = 0.366. In 63.2% AH jump was induced by both pacing modes; in 17.8% - only by burst pacing; in 14.8% - only by programmed pacing; in 4.2% there was no inducible jump. There was negative correlation between both pacing modes, ρ = -0.204, Р<0.001. Burst and programmed atrial stimulation separately prove the presence of dual AV nodal physiology in 81 and 78% of the patients with AVNRT, respectively. There is negative correlation between the two pacing modes, allowing the combination of the two methods to prove diagnostic in 95.8% of the patients. Copyright © 2017 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  14. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    OpenAIRE

    Domenico Santarsiero

    2008-01-01

    The Applanix POS/LV platform in cinematic laser scanner applicationsOn the 11th of march the GEOmedia editorial unit had the pleasure of hosting a technical meeting dedicated to the Applanix LANDMark new Position and Orientation System for Land Vehicles (POS/LV)field test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products) and Terenzio Mariani (Sales manager for Italy), helped to test the functionalities of a complete POS/LV system equ...

  15. Dual-band infrared capabilities for imaging buried object sites

    Energy Technology Data Exchange (ETDEWEB)

    Del Grande, N.K.; Durbin, P.F.; Gorvad, M.R.; Perkins, D.E.; Clark, G.A.; Hernandez, J.E.; Sherwood, R.J.

    1993-04-02

    We discuss dual-band infrared (DBIR) capabilities for imaging buried object sizes. We identify physical features affecting thermal contrast needed to distinguish buried object sites from undisturbed sites or surface clutter. Apart from atmospheric transmission and system performance, these features include: object size, shape, and burial depth; ambient soil, disturbed soil and object site thermal diffusivity differences; surface temperature, emissivity, plant-cover, slope, albedo and roughness variations; weather conditions and measurement times. We use good instrumentation to measure the time-varying temperature differences between buried object sites and undisturbed soil sites. We compare near surface soil temperature differences with radiometric infrared (IR) surface temperature differences recorded at 4.7 {plus_minus} 0.4 {mu}m and at 10.6 {plus_minus} 1.0 {mu}m. By producing selective DBIR image ratio maps, we distinguish temperature-difference patterns from surface emissivity effects. We discuss temperature differences between buried object sites, filled hole site (without buried objects), cleared (undisturbed) soil sites, and grass-covered sites (with and without different types of surface clutter). We compare temperature, emissivity-ratio, visible and near-IR reflectance signatures of surface objects, leafy plants and sod. We discuss the physical aspects of environmental, surface and buried target features affecting interpretation of buried targets, surface objects and natural backgrounds.

  16. Optimal construction and delivery of dual-functioning lentiviral vectors for type I collagen-suppressed chondrogenesis in synovium-derived mesenchymal stem cells.

    Science.gov (United States)

    Zhang, Feng; Yao, Yongchang; Zhou, Ruijie; Su, Kai; Citra, Fudiman; Wang, Dong-An

    2011-06-01

    This study aims to deliver both transforming growth factor β3 (TGF-β3) and shRNA targeting type I collagen (Col I) by optimal construction and application of various dual-functioning lentiviral vectors to induce Col I-suppressed chondrogenesis in synovium-derived mesenchymal stem cells (SMSCs). We constructed four lentiviral vectors (LV-1, LV-2, LV-3 and LV-4) with various arrangements of the two expression cassettes in different positions and orientations. Col I inhibition efficiency and chondrogenic markers were assessed with qPCR, ELISA and staining techniques. Among the four vectors, LV-1 has two distant and reversely oriented cassettes, LV-2 has two distant and same-oriented cassettes, LV-3 has two proximal and reversely oriented cassettes, and LV-4 has two proximal and same-oriented cassettes. Col I and chondrogenic markers, including type II collagen (Col II), aggrecan and glycosaminoglycan (GAG), were examined in SMSCs cultured in 3-D alginate hydrogel. All of the four vectors showed distinct effects in Col I level as well as diverse inductive efficiencies in upregulation of the cartilaginous markers. Based on real-time PCR results, LV-1 was optimal towards Col I-suppressed chondrogenesis. LV-1 vector is competent to promote Col I-suppressed chondrogenesis in SMSCs.

  17. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  18. Impact Study of Electric Vehicle (EV) Integration on Low Voltage (LV) Grids

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cha, Seung-Tae; Nielsen, Arne Hejde

    2012-01-01

    the single line diagram (SLD) of the LV grid. The demand profiles of end-users are determined by the end-user yearly consumption and avreaged demand profiles of different customer types in Denmark. Five charging scenarios have been tested using the developed LV grid. The first two charging scenarios are dumb....... The two charging power levels are 1 phase 16 A and 3 phase 16 A. The loading of the power components and voltage profile are analyzed to quantify the impact of the charging scenarios and charging power levels on LV grids....

  19. Preventing phrenic nerve stimulation by a patch insulation in an intact swine heart model.

    Directory of Open Access Journals (Sweden)

    Jin-Long Huang

    Full Text Available Phrenic nerve stimulation (PNS could be prevented by a silastic patch over the epicardial lead. We studied the effects in preventing PNS by placing a silastic patch directly over an epicardial lead or placing a graft around the phrenic nerve (PN.Fourteen Lanyu swine were enrolled. A bipolar lead was placed epicardially on the left ventricle (LV inferior to the PN. An implantable cardioverter-defibrillator (ICD lead was placed into the right ventricle (RV. The maximal influential distance (MID was measured under 3 pacing configurations to express the influential electrical field on the PN. The threshold of the LV and PN were evaluated epicardially. Then, PTFE patches of different sizes (10×10 mm, 20×20 mm and 30×30 mm were placed between the LV lead and PN to study the rise in PN threshold in 7 swine. On the other hand, the PN were surrounded by a PTFE graft of different lengths (10 mm, 20 mm, and 30 mm in the remaining 7 swine. LV-bipolar pacing showed the shortest MID when compared to the other 2 unipolar pacing configurations at pacing voltage of 10 V. The patch was most effective in preventing PNS during LV-bipolar pacing. PNS was prevented under all circumstances with a larger PTFE patch (30×30 mm or long graft (30 mm.PNS was avoided by placing a PTFE patch over the LV lead or a graft around the PN despite pacing configurations. Hence if PNS persisted during CRT implantation, a PTFE patch on the LV lead or a graft around the PN could be considered.

  20. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of

  1. Dual and multi-stimuli responsive polymeric nanoparticles for programmed site-specific drug delivery.

    Science.gov (United States)

    Cheng, Ru; Meng, Fenghua; Deng, Chao; Klok, Harm-Anton; Zhong, Zhiyuan

    2013-05-01

    In the past decades, polymeric nanoparticles have emerged as a most promising and viable technology platform for targeted and controlled drug delivery. As vehicles, ideal nanoparticles are obliged to possess high drug loading levels, deliver drug to the specific pathological site and/or target cells without drug leakage on the way, while rapidly unload drug at the site of action. To this end, various "intelligent" polymeric nanoparticles that release drugs in response to an internal or external stimulus such as pH, redox, temperature, magnetic and light have been actively pursued. These stimuli-responsive nanoparticles have demonstrated, though to varying degrees, improved in vitro and/or in vivo drug release profiles. In an effort to further improve drug release performances, novel dual and multi-stimuli responsive polymeric nanoparticles that respond to a combination of two or more signals such as pH/temperature, pH/redox, pH/magnetic field, temperature/reduction, double pH, pH and diols, temperature/magnetic field, temperature/enzyme, temperature/pH/redox, temperature/pH/magnetic, pH/redox/magnetic, temperature/redox/guest molecules, and temperature/pH/guest molecules have recently been developed. Notably, these combined responses take place either simultaneously at the pathological site or in a sequential manner from nanoparticle preparation, nanoparticle transporting pathways, to cellular compartments. These dual and multi-stimuli responsive polymeric nanoparticles have shown unprecedented control over drug delivery and release leading to superior in vitro and/or in vivo anti-cancer efficacy. With programmed site-specific drug delivery feature, dual and multi-stimuli responsive nanoparticulate drug formulations have tremendous potential for targeted cancer therapy. In this review paper, we highlight the recent exciting developments in dual and multi-stimuli responsive polymeric nanoparticles for precision drug delivery applications, with a particular focus

  2. Pacing stress echocardiography

    Directory of Open Access Journals (Sweden)

    Agrusta Marco

    2005-12-01

    Full Text Available Abstract Background High-rate pacing is a valid stress test to be used in conjunction with echocardiography; it is independent of physical exercise and does not require drug administration. There are two main applications of pacing stress in the echo lab: the noninvasive detection of coronary artery disease through induction of a regional transient dysfunction; and the assessment of contractile reserve through peak systolic pressure/ end-systolic volume relationship at increasing heart rates to assess global left ventricular contractility. Methods The pathophysiologic rationale of pacing stress for noninvasive detection of coronary artery disease is obvious, with the stress determined by a controlled increase in heart rate, which is a major determinant of myocardial oxygen demand, and thereby tachycardia may exceed a fixed coronary flow reserve in the presence of hemodynamically significant coronary artery disease. The use of pacing stress echo to assess left ventricular contractile reserve is less established, but promising. Positive inotropic interventions are mirrored by smaller end-systolic volumes and higher end-systolic pressures. An increased heart rate progressively increases the force of ventricular contraction (Bowditch treppe or staircase phenomenon. To build the force-frequency relationship, the force is determined at different heart rate steps as the ratio of the systolic pressure (cuff sphygmomanometer/end-systolic volume index (biplane Simpson rule. The heart rate is determined from ECG. Conclusion Two-dimensional echocardiography during pacing is a useful tool in the detection of coronary artery disease. Because of its safety and ease of repeatability noninvasive pacing stress echo can be the first-line stress test in patients with permanent pacemaker. The force-frequency can be defined as up- sloping (normal when the peak stress pacing systolic pressure/end-systolic volume index is higher than baseline and intermediate stress

  3. PACE Status Update

    Energy Technology Data Exchange (ETDEWEB)

    M., Zimring,; Hoffman, I.; Fuller, M.

    2010-08-11

    The Federal Housing Finance Agency (FHFA) regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On July 6, 2010, FHFA and the Office of the Comptroller of the Currency (OCC) concluded that Property Assessed Clean Energy (PACE) programs 'present significant safety and soundness concerns' to the housing finance industry. This statement came after a year of discussions with state and federal agencies in which PACE, a novel mechanism for financing energy efficiency and renewable energy improvements, has gone from receiving support from the White House, canonization as one of Scientific American's 'World Changing Ideas' and legislative adoption in 24 states to questionable relevance, at least in the residential sector. Whether PACE resumes its expansion as an innovative tool for financing energy efficiency and clean generation depends on outcomes in each of the three branches of government - discussions on a PACE pilot phase among federal agencies, litigation in federal court, and legislation in Congress - all highly uncertain. This policy brief addresses the practical impacts of these possible outcomes on existing and emerging PACE programs across the United States and potential paths forward.

  4. Formation and characterization of FeLV iscoms.

    NARCIS (Netherlands)

    L. Akerblom; K. Strö mstedt; S. Hö glund; A.D.M.E. Osterhaus (Albert); B. Morein (Bror)

    1989-01-01

    textabstractImmunostimulating complexes (ISCOMs) have been prepared from feline leukaemia virus (FeLV) envelope proteins. The ISCOMs were characterized biochemically in SDS-polyacrylamide gel electrophoresis showing the presence of proteins of estimated molecular weights of 15,000, 27,000 and

  5. Role of the Purkinje-Muscle Junction on the Ventricular Repolarization Heterogeneity in the Healthy and Ischemic Ovine Ventricular Myocardium

    Directory of Open Access Journals (Sweden)

    Marine E. Martinez

    2018-06-01

    Full Text Available Alteration of action potential duration (APD heterogeneity contributes to arrhythmogenesis. Purkinje-muscle junctions (PMJs present differential electrophysiological properties including longer APD. The goal of this study was to determine if Purkinje-related or myocardial focal activation modulates ventricular repolarization differentially in healthy and ischemic myocardium. Simultaneous epicardial (EPI and endocardial (ENDO optical mapping was performed on sheep left ventricular (LV wedges with intact free-running Purkinje network (N = 7. Preparations were paced on either ENDO or EPI surfaces, or the free-running Purkinje fibers (PFs, mimicking normal activation. EPI and ENDO APDs were assessed for each pacing configuration, before and after (7 min of the onset of no-flow ischemia. Experiments were supported by simulations. In control conditions, maximal APD was found at endocardial PMJ sites. We observed a significant transmural APD gradient for PF pacing with PMJ APD = 347 ± 41 ms and EPI APD = 273 ± 36 ms (p < 0.001. A similar transmural gradient was observed when pacing ENDO (49 ± 31 ms; p = 0.005. However, the gradient was reduced when pacing EPI (37 ± 20 ms; p = 0.005. Global dispersion of repolarization was the most pronounced for EPI pacing. In ischemia, both ENDO and EPI APD were reduced (p = 0.005 and the transmural APD gradient (109 ± 55 ms was increased when pacing ENDO compared to control condition or when pacing EPI (p < 0.05. APD maxima remained localized at functional PMJs during ischemia. Local repolarization dispersion was significantly higher at the PMJ than at other sites. The results were consistent with simulations. We found that the activation sequence modulates repolarization heterogeneity in the ischemic sheep LV. PMJs remain active following ischemia and exert significant influence on local repolarization patterns.

  6. LV function monitoring to discard functional abnormalities in athletes with altered ventricular re-polarization

    International Nuclear Information System (INIS)

    Flotats, A.; Camacho, V.; Mena, E.; Tembl, A.; Estorch, M.; Carrio, I.; Serra-Grima, R.; Borras, X.; Cinca, J.

    2002-01-01

    Aim: Marked ventricular re-polarization abnormalities (MRA) in athletes may suggest the presence of associated heart disease. Assessment of LV function during exercise may contribute to rule out heart disease and help to decide continuation of physical training. The aim of the study was to assess whether athletes with MRA show a particular response of LV function to exhausting exercise. Material and Methods: Thirty-nine male athletes underwent monitoring of LV function with a miniaturised radionuclide detector (VEST, Capintec, Inc.) during bicycle exhausting exercise. There were 22 athletes with MRA in the ECG at rest (negative T waves equal or more than 2mm in up to 3 ECG leads) and 17 with normal ECG. All were symptom free. Age and physical fitness were comparable in both groups. Clinical examination, ECG, exercise test and echocardiography were performed in all athletes. Results: In all cases LV wall thickness was that expected for highly conditioned sportsmen. Both groups of athletes attained a similar energy expenditure. During exercise, athletes with MRA showed a tendency to normalise re-polarization. There were no differences in heart rate, LV end-systolic volume, LVEF, cardiac output , and peak ejection and filling rates at rest, 50%, 75%, 85% and 100% of peak HR, nor at 2, 5 and 10 min of recovery between both groups of athletes. At rest stroke volume was lower in athletes with MRA (60% vs. 64%, p=0.044). There were also no differences in LV end-diastolic volume (EDV), except at peak HR, when EDV increased in athletes with normal ECG while it decreased in athletes with MRA (p=0.047). Conclusions: The presence of marked ventricular re-polarization abnormalities in athletes does not substantially affect exercise performance nor LV function and should not preclude physical training. The VEST is a useful means to assess LV function during exhausting upright bicycle exercise

  7. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for

  8. Biodegradation of di-n-butyl phthalate by bacterial consortium LV-1 enriched from river sludge.

    Directory of Open Access Journals (Sweden)

    Yangyang Wang

    Full Text Available A stable bacterial consortium (LV-1 capable of degrading di-n-butyl phthalate (DBP was enriched from river sludge. Community analysis revealed that the main families of LV-1 are Brucellaceae (62.78% and Sinobacteraceae (14.83%, and the main genera of LV-1 are Brucella spp. (62.78% and Sinobacter spp. (14.83%. The optimal pH and temperature for LV-1 to degrade DBP were pH 6.0 and 30°C, respectively. Inoculum size influenced the degradation ratio when the incubation time was < 24 h. The initial concentration of DBP also influenced the degradation rates of DBP by LV-1, and the degradation rates ranged from 69.0-775.0 mg/l/d in the first 24 h. Degradation of DBP was best fitted by first-order kinetics when the initial concentration was < 300 mg/l. In addition, Cd2+, Cr6+, and Zn2+ inhibited DBP degradation by LV-1 at all considered concentrations, but low concentrations of Pb2+, Cu2+, and Mn2+ enhanced DBP degradation. The main intermediates (mono-ethyl phthalate [MEP], mono-butyl phthalate [MBP], and phthalic acid [PA] were identified in the DBP degradation process, thus a new biochemical pathway of DBP degradation is proposed. Furthermore, LV-1 also degraded other phthalates with shorter ester chains (DMP, DEP, and PA.

  9. EV Charging Facilities and Their Application in LV Feeders with Photovoltaics

    DEFF Research Database (Denmark)

    Marra, Francesco; Yang, Guangya; Træholt, Chresten

    2013-01-01

    Low-voltage (LV) grid feeders with high penetration of photovoltaics (PVs) are often affected by voltage magnitude problems. To solve such issues, previous research has shown that reactive power methods, active power curtailment and grid reinforcement can be used for voltage support, yet showing...... several limits. We introduce the use of electric vehicle (EV) public charging stations with energy storage system (ESS) as a solution for voltage regulation in LV feeders with PV. A novel method is proposed to determine the ESS charging load required for voltage regulation and compare the results...... for the different locations in the feeder. With time-series simulations, we quantify the energy size required for a station ESS. A Belgian LV residential grid, modeled using real PV generation and load profiles, is used as case study. The method and simulation results show the effectiveness of using public EV...

  10. Dual-source computed tomography. Effect on regional and global left ventricular function assessment compared to magnetic resonance imaging; Untersuchung der regionalen und globalen linksventrikulaeren Funktion mit der Dual-Source-Computertomografie im Vergleich zur Magnetresonanztomografie

    Energy Technology Data Exchange (ETDEWEB)

    Lueders, F.; Seifarth, H.; Wessling, J.; Heindel, W.; Juergens, Kai Uwe [Inst. fuer Klinische Radiologie, Universitaetsklinikum Muenster (Germany); Fischbach, R. [Klinik fuer Radiologie, Nuklearmedizin und Neuroradiologie, Asklepios Klinik Altona (Germany)

    2009-10-15

    Purpose: to determine regional and global left ventricular (LV) functional parameters and to perform segmental wall thickness (SWT) and motion (WM) analysis of dual source CT (DSCT) with optimized temporal resolution versus MRI. Materials and Methods: 30 patients with known or suspected CAD, non-obstructive HCM, DCM, ARVCM, Fallot Tetralogy, cardiac sarcoidosis and cardiac metastasis underwent DSCT and MRI. The DSCT and MR images were evaluated: end-systolic (ESV), end-diastolic LV (EDV) volumes, stroke volume (SV), ejection fraction (EF), and myocardial mass (MM) as well as LV wall thickening and segmental WM applying the AHA model were obtained and statistically analyzed. Results: The mean LV-EDV (r = 0.96) and ESV (r = 0.98) as well as LV-EF (r = 0.97), SV (r = 0.83), and MM (r = 0.95) correlated well. Bland Altman analysis revealed little systematic underestimation of LV-EF (-1.1 {+-} 7.8%), EDV (-0.3 {+-} 18.2 ml), SV (-1.3 {+-} 16.7 ml) and little overestimation of ESV (1.1 {+-} 7.8 ml) and MM (12.8 {+-} 14.4 g) determined by DSCT. Systolic reconstruction time points correlated well (DSCT 32.2 {+-} 6.7 vs. MRI 35.6 {+-} 4.4% RR-interval). The LV wall thickness obtained by DSCT and MRI showed close correlation in all segments (diameter diff 0.42 {+-} 1 mm). In 413 segments (89%) WM abnormalities were equally rated, whereas DSCT tended to underestimate the degree of wall motion impairment. Conclusion: DSCT with optimized temporal resolution enables regional and global LV function analysis as well as segmental WM analysis in good correlation with MRI. However, the degree of WM impairment is slightly underestimated by DSCT. (orig.)

  11. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    Science.gov (United States)

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  12. Risk perception influences athletic pacing strategy.

    Science.gov (United States)

    Micklewright, Dominic; Parry, David; Robinson, Tracy; Deacon, Greg; Renfree, Andrew; St Clair Gibson, Alan; Matthews, William J

    2015-05-01

    The objective of this study is to examine risk taking and risk perception associations with perceived exertion, pacing, and performance in athletes. Two experiments were conducted in which risk perception was assessed using the domain-specific risk taking (DOSPERT) scale in 20 novice cyclists (experiment 1) and 32 experienced ultramarathon runners (experiment 2). In experiment 1, participants predicted their pace and then performed a 5-km maximum effort cycling time trial on a calibrated Kingcycle mounted bicycle. Split times and perceived exertion were recorded every kilometer. In experiment 2, each participant predicted their split times before running a 100-km ultramarathon. Split times and perceived exertion were recorded at seven checkpoints. In both experiments, higher and lower risk perception groups were created using median split of DOSPERT scores. In experiment 1, pace during the first kilometer was faster among lower risk perceivers compared with higher risk perceivers (t(18) = 2.0, P = 0.03) and faster among higher risk takers compared with lower risk takers (t(18) = 2.2, P = 0.02). Actual pace was slower than predicted pace during the first kilometer in both the higher risk perceivers (t(9) = -4.2, P = 0.001) and lower risk perceivers (t(9) = -1.8, P = 0.049). In experiment 2, pace during the first 36 km was faster among lower risk perceivers compared with higher risk perceivers (t(16) = 2.0, P = 0.03). Irrespective of risk perception group, actual pace was slower than predicted pace during the first 18 km (t(16) = 8.9, P risk perception groups. Initial pace is associated with an individual's perception of risk, with low perceptions of risk being associated with a faster starting pace. Large differences between predicted and actual pace suggest that the performance template lacks accuracy, perhaps indicating greater reliance on momentary pacing decisions rather than preplanned strategy.

  13. Benazepril inhibited the NF-κB and TGF-β networking on LV hypertrophy in rats.

    Science.gov (United States)

    Yan, Shi-Hai; Zhao, Ning-Wei; Zhu, Xuan-Xuan; Wang, Qiong; Wang, Hai-Dan; Fu, Rui; Sun, Yuan; Li, Qi-Yi

    2013-05-01

    Benazepril, an angiotensin-converting enzyme (ACE) inhibitor, has been used to treat hypertension, congestive heart failure, and chronic renal failure. However, its biological activity and mechanism of action in inflammation are not fully identified. The present study was designed to determine the in vivo anti-inflammatory effects of benazepril on LV hypertrophy in rats. LV hypertrophy was produced in rats by abdominal aortic coarctation. They were then divided into the following groups: sham operation; LV hypertrophy; LV hypertrophy+benazepril (1mg/kg in a gavage, once a day for 4 weeks). Both morphological assays (hemodynamic and hemorheological measurement; LV hypertrophy assessment), and molecular assays (protein levels of Collagen type I/III, TNF-α and VCAM-1; TGF-β gene expression; NF-κB or Smad activation; intracellular ROS production) were performed. The following effects were observed in rats treated with benazepril: (1) marked improvements in hemodynamic and hemorheological parameters; (2) significant reductions in LV hypertrophy, dilatation and fibrosis; (3) significantly attenuated protein levels of Collagen type I/III, TGF-β, TNF-α and VCAM-1, NF-κB or Smad activation, as well as intracellular ROS production. These results suggest that the anti-inflammatory properties of benazepril may be ascribed to their down-regulation of both NF-κB and TGF-β signaling pathways by acting on the intracellular ROS production in rats with LV hypertrophy, thus supporting the use of benazepril as an anti-inflammatory agent. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. 42 CFR 460.60 - PACE organizational structure.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE organizational structure. 460.60 Section 460... ELDERLY (PACE) PACE Administrative Requirements § 460.60 PACE organizational structure. (a) A PACE organization must be, or be a distinct part of, one of the following: (1) An entity of city, county, State, or...

  15. Novel bis-(−)-nor-meptazinol derivatives act as dual binding site AChE inhibitors with metal-complexing property

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Wei [Department of Medicinal Chemistry, School of Pharmacy, Fudan University, 826 Zhangheng Road, Shanghai 200032 (China); NPFPC Key Laboratory of Contraceptives and Devices, Shanghai Institute of Planned Parenthood Research, 2140 Xietu Road, Shanghai 200032 (China); Li, Juan [Department of Pharmacology, Institute of Medical Sciences, Shanghai Jiaotong University School of Medicine, 280 South Chongqing Road, Shanghai 200025 (China); Qiu, Zhuibai [Department of Medicinal Chemistry, School of Pharmacy, Fudan University, 826 Zhangheng Road, Shanghai 200032 (China); Xia, Zheng [Department of Pharmacology, Institute of Medical Sciences, Shanghai Jiaotong University School of Medicine, 280 South Chongqing Road, Shanghai 200025 (China); Li, Wei [Department of Medicinal Chemistry, School of Pharmacy, Fudan University, 826 Zhangheng Road, Shanghai 200032 (China); Yu, Lining; Chen, Hailin; Chen, Jianxing [NPFPC Key Laboratory of Contraceptives and Devices, Shanghai Institute of Planned Parenthood Research, 2140 Xietu Road, Shanghai 200032 (China); Chen, Yan; Hu, Zhuqin; Zhou, Wei; Shao, Biyun; Cui, Yongyao [Department of Pharmacology, Institute of Medical Sciences, Shanghai Jiaotong University School of Medicine, 280 South Chongqing Road, Shanghai 200025 (China); Xie, Qiong, E-mail: xiejoanxq@gmail.com [Department of Medicinal Chemistry, School of Pharmacy, Fudan University, 826 Zhangheng Road, Shanghai 200032 (China); Chen, Hongzhuan, E-mail: yaoli@shsmu.edu.cn [Department of Pharmacology, Institute of Medical Sciences, Shanghai Jiaotong University School of Medicine, 280 South Chongqing Road, Shanghai 200025 (China)

    2012-10-01

    The strategy of dual binding site acetylcholinesterase (AChE) inhibition along with metal chelation may represent a promising direction for multi-targeted interventions in the pathophysiological processes of Alzheimer's disease (AD). In the present study, two derivatives (ZLA and ZLB) of a potent dual binding site AChE inhibitor bis-(−)-nor-meptazinol (bis-MEP) were designed and synthesized by introducing metal chelating pharmacophores into the middle chain of bis-MEP. They could inhibit human AChE activity with IC{sub 50} values of 9.63 μM (for ZLA) and 8.64 μM (for ZLB), and prevent AChE-induced amyloid-β (Aβ) aggregation with IC{sub 50} values of 49.1 μM (for ZLA) and 55.3 μM (for ZLB). In parallel, molecular docking analysis showed that they are capable of interacting with both the catalytic and peripheral anionic sites of AChE. Furthermore, they exhibited abilities to complex metal ions such as Cu(II) and Zn(II), and inhibit Aβ aggregation triggered by these metals. Collectively, these results suggest that ZLA and ZLB may act as dual binding site AChEIs with metal-chelating potency, and may be potential leads of value for further study on disease-modifying treatment of AD. -- Highlights: ► Two novel bis-(−)-nor-meptazinol derivatives are designed and synthesized. ► ZLA and ZLB may act as dual binding site AChEIs with metal-chelating potency. ► They are potential leads for disease-modifying treatment of Alzheimer's disease.

  16. Novel bis-(−)-nor-meptazinol derivatives act as dual binding site AChE inhibitors with metal-complexing property

    International Nuclear Information System (INIS)

    Zheng, Wei; Li, Juan; Qiu, Zhuibai; Xia, Zheng; Li, Wei; Yu, Lining; Chen, Hailin; Chen, Jianxing; Chen, Yan; Hu, Zhuqin; Zhou, Wei; Shao, Biyun; Cui, Yongyao; Xie, Qiong; Chen, Hongzhuan

    2012-01-01

    The strategy of dual binding site acetylcholinesterase (AChE) inhibition along with metal chelation may represent a promising direction for multi-targeted interventions in the pathophysiological processes of Alzheimer's disease (AD). In the present study, two derivatives (ZLA and ZLB) of a potent dual binding site AChE inhibitor bis-(−)-nor-meptazinol (bis-MEP) were designed and synthesized by introducing metal chelating pharmacophores into the middle chain of bis-MEP. They could inhibit human AChE activity with IC 50 values of 9.63 μM (for ZLA) and 8.64 μM (for ZLB), and prevent AChE-induced amyloid-β (Aβ) aggregation with IC 50 values of 49.1 μM (for ZLA) and 55.3 μM (for ZLB). In parallel, molecular docking analysis showed that they are capable of interacting with both the catalytic and peripheral anionic sites of AChE. Furthermore, they exhibited abilities to complex metal ions such as Cu(II) and Zn(II), and inhibit Aβ aggregation triggered by these metals. Collectively, these results suggest that ZLA and ZLB may act as dual binding site AChEIs with metal-chelating potency, and may be potential leads of value for further study on disease-modifying treatment of AD. -- Highlights: ► Two novel bis-(−)-nor-meptazinol derivatives are designed and synthesized. ► ZLA and ZLB may act as dual binding site AChEIs with metal-chelating potency. ► They are potential leads for disease-modifying treatment of Alzheimer's disease.

  17. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  18. Left Ventricle: Fully Automated Segmentation Based on Spatiotemporal Continuity and Myocardium Information in Cine Cardiac Magnetic Resonance Imaging (LV-FAST

    Directory of Open Access Journals (Sweden)

    Lijia Wang

    2015-01-01

    Full Text Available CMR quantification of LV chamber volumes typically and manually defines the basal-most LV, which adds processing time and user-dependence. This study developed an LV segmentation method that is fully automated based on the spatiotemporal continuity of the LV (LV-FAST. An iteratively decreasing threshold region growing approach was used first from the midventricle to the apex, until the LV area and shape discontinued, and then from midventricle to the base, until less than 50% of the myocardium circumference was observable. Region growth was constrained by LV spatiotemporal continuity to improve robustness of apical and basal segmentations. The LV-FAST method was compared with manual tracing on cardiac cine MRI data of 45 consecutive patients. Of the 45 patients, LV-FAST and manual selection identified the same apical slices at both ED and ES and the same basal slices at both ED and ES in 38, 38, 38, and 41 cases, respectively, and their measurements agreed within -1.6±8.7 mL, -1.4±7.8 mL, and 1.0±5.8% for EDV, ESV, and EF, respectively. LV-FAST allowed LV volume-time course quantitatively measured within 3 seconds on a standard desktop computer, which is fast and accurate for processing the cine volumetric cardiac MRI data, and enables LV filling course quantification over the cardiac cycle.

  19. Exercise capacity and N-terminal pro-brain natriuretic peptide levels with biventricular vs. right ventricular pacing for atrioventricular block: results from the PREVENT-HF German Substudy.

    Science.gov (United States)

    Stockburger, Martin; de Teresa, Eduardo; Lamas, Gervasio; Desaga, Martin; Koenig, Carsten; Habedank, Dirk; Cobo, Erik; Navarro, Xavier; Wiegand, Uwe

    2014-01-01

    Previous studies showed unfavourable effects of right ventricular (RV) pacing. Ventricular pacing (VP), however, is required in many patients with atrioventricular (AV) block. The PREVENT-HF study explored left ventricular (LV) remodelling during RV vs. biventricular (BIV) pacing in AV block without advanced heart failure. The pre-specified PREVENT-HF German Substudy examined exercise capacity and N-terminal pro-brain natriuretic peptide (NT-proBNP). Patients with expected VP ≥80% were randomized to RV or BIV pacing. Endpoints were peak oxygen uptake (pVO2), oxygen uptake at the anaerobic threshold (VO2AT), ventilatory efficiency (VE/VCO2), and logNT-proBNP. Considering crossover, intention to treat (ITT), and on-treatment (OT) analyses of covariance (ANCOVA) were performed. For exercise testing 44 (RV: 25, BIV: 19), and for NT-proBNP 53 patients (RV: 29, BIV: 24) were included. The ITT analysis revealed significant differences in pVO2 [ANCOVA effect 2.83 mL/kg/min, confidence interval (CI) 0.83-4.91, P = 0.007], VO2AT (ANCOVA effect 2.14 mL/min/k, CI 0.14-4.15, P = 0.03), and VE/VCO2 (ANCOVA effect -5.46, CI -10.79 to -0.13, P = 0.04) favouring BIV randomization. The significant advantage in pVO2 persisted in OT analysis, while VO2AT and VE/VCO2 showed trends favouring BIV pacing. LogNT-proBNP did not differ between groups. (ITT: ANCOVA effect 0.008, CI -0.40 to +0.41, P = 0.97; OT: ANCOVA effect -0.03, CI -0.44 to 0.30, P = 0.90). Our study suggests that BIV pacing produces better exercise capacity over 1 year compared with RV pacing in patients without advanced heart failure and AV block. In contrast, we observed no significant changes of NT-proBNP. Larger trials will allow appraising the clinical usefulness of BIV pacing in AV block. ClinicalTrials.gov Identifier: NCT00170326.

  20. Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity.

    Science.gov (United States)

    Zhang, Hai-Bo; Meng, Xu; Han, Jie; Li, Yan; Zhang, Ye; Jiang, Teng-Yong; Zhao, Ying-Xin; Zhou, Yu-Jie

    2017-04-01

    Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques. We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study. Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing. Intra- and inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure. Before CRT procedure, the mean QRS-duration, maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12), standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD), and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 ± 17 ms and 170 ± 21 ms, 391 ± 42 ms and 397 ± 36 ms, 144 ± 30 ms and 148 ± 22 ms, 58 ± 25 ms and 60 ± 36 ms, respectively (all P > 0.05). At one year after the CRT, the mean QRS-duration, LV Ts-12, LV Ts-SD, and IVMD in TV and OP group were 128 ± 14 ms and 141 ± 22 ms ( P = 0.031), 136 ± 37 ms and 294 ± 119 ms ( P = 0.023), 50 ± 22 ms and 96 ± 34 ms ( P = 0.015), 27 ± 11 ms and 27 ± 26 ms ( P = 0.86), respectively. The LV lead implantation procedure time was 53.4 ± 16.3 min for OP group and 136 ± 35.1 min for TV group ( P = 0.016). The mean LV pacing threshold increased significantly from 1.7 ± 0.6 V/0.5 ms to 2.3 ± 1.6 V/0.5 ms ( P open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.

  1. The surface glycoprotein of a natural feline leukemia virus subgroup A variant, FeLV-945, as a determinant of disease outcome.

    Science.gov (United States)

    Bolin, Lisa L; Ahmad, Shamim; Levy, Laura S

    2011-10-15

    Feline leukemia virus (FeLV) is a natural retrovirus of domestic cats associated with degenerative, proliferative and malignant diseases. Studies of FeLV infection in a cohort of naturally infected cats were undertaken to examine FeLV variation, the selective pressures operative in FeLV infection that lead to predominance of natural variants, and the consequences for infection and disease progression. A unique variant, designated FeLV-945, was identified as the predominant isolate in the cohort and was associated with non-T-cell diseases including multicentric lymphoma. FeLV-945 was assigned to the FeLV-A subgroup based on sequence analysis and receptor utilization, but was shown to differ in sequence from a prototype member of FeLV-A, designated FeLV-A/61E, in the long terminal repeat (LTR) and the surface glycoprotein gene (SU). A unique sequence motif in the FeLV-945 LTR was shown to function as a transcriptional enhancer and to confer a replicative advantage. The FeLV-945 SU protein was observed to differ in sequence as compared to FeLV-A/61E within functional domains known to determine receptor selection and binding. Experimental infection of newborn cats was performed using wild type FeLV-A/61E or recombinant FeLV-A/61E in which the LTR (61E/945L) or LTR and SU (61E/945SL) were exchanged for that of FeLV-945. Infection with either FeLV-A/61E or 61E/945L resulted in T-cell lymphoma of the thymus, although 61E/945L caused disease significantly more rapidly. In contrast, infection with 61E/945SL resulted in the rapid induction of a multicentric lymphoma of B-cell origin, thus recapitulating the outcome of natural infection and implicating FeLV-945 SU as a determinant of disease outcome. Recombinant FeLV-B was detected infrequently and at low levels in multicentric lymphomas, and was thereby not implicated in disease induction. Preliminary studies of receptor interaction indicated that virus particles bearing FeLV-945 SU bind to the FeLV-A receptor more

  2. Optogenetic pacing in Drosophila melanogaster

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Tanzi, Rudolph E.; Zhou, Chao

    2015-01-01

    Electrical stimulation is currently the gold standard for cardiac pacing. However, it is invasive and nonspecific for cardiac tissues. We recently developed a noninvasive cardiac pacing technique using optogenetic tools, which are widely used in neuroscience. Optogenetic pacing of the heart provides high spatial and temporal precisions, is specific for cardiac tissues, avoids artifacts associated with electrical stimulation, and therefore promises to be a powerful tool in basic cardiac research. We demonstrated optogenetic control of heart rhythm in a well-established model organism, Drosophila melanogaster. We developed transgenic flies expressing a light-gated cation channel, channelrhodopsin-2 (ChR2), specifically in their hearts and demonstrated successful optogenetic pacing of ChR2-expressing Drosophila at different developmental stages, including the larva, pupa, and adult stages. A high-speed and ultrahigh-resolution optical coherence microscopy imaging system that is capable of providing images at a rate of 130 frames/s with axial and transverse resolutions of 1.5 and 3.9 μm, respectively, was used to noninvasively monitor Drosophila cardiac function and its response to pacing stimulation. The development of a noninvasive integrated optical pacing and imaging system provides a novel platform for performing research studies in developmental cardiology. PMID:26601299

  3. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi [Dept. of Radiology, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan)], e-mail: radokada@yamaguchi-u.ac.jp; Morikage, Noriyasu [Medical Bioregulation Dept. of Organ Regulatory Surgery, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan); Sano, Yuichi [Dept. of Radiology, Yamaguchi Univ. Hospital, Yamaguchi (Japan); Suga, Kazuyoshi [Dept. of Radiology, St Hills Hospital, Yamaguchi (Japan)

    2013-07-15

    Background: Dual-energy perfusion CT (DE{sub p}CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE{sub p}CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE{sub p}CT using a 64-slice dual-source CT. DE{sub p}CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V{sub 120}), 1-15 HU (V{sub 15}), 1-10 HU (V{sub 10}), and 1-5 HU (V{sub 5}). Each relative ratio per V{sub 120} was expressed as the %V{sub 15}, %V{sub 10}, and %V{sub 5}. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V{sub 15}, V{sub 10}, V{sub 5}, %V{sub 15}, %V{sub 10}, and %V{sub 5} were also significantly higher than those without IPC (P = 0.001). %V{sub 5} had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. Conclusion: The volumetric evaluation by DE{sub p}CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.

  4. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    Science.gov (United States)

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential

  5. Temporary pacing

    Directory of Open Access Journals (Sweden)

    L.J. Workman

    1983-09-01

    Full Text Available Artificial cardiac pacing, the use of electrical stimuli to cause contraction of heart muscle, is a sophisticated therapeutic and diagnostic tool. Its rapid technologic improvement since first developed in the late 1930’s by Hyman, has made it possible not only to avoid certain cases of death due to heart block, but also to extend and improve the quality of life. Pacemaker therapy is generally used to treat heart rate or rhythm disturbances, being either tachy- or bradyarrhythmias that produce a detrimental drop in cardiac output. Of the many different types of pacemakers and electrodes currently available, ventricular demand pacing is the most commonly used.

  6. Protection of LV system against lightning

    OpenAIRE

    Yordanova Nedyalkova, Greta

    2010-01-01

    Lightning is a natural hazard and one of the greatest local mysteries. Scientists have not fully understood the mechanism of lightning. It is one of the most beautiful displays in nature and one of the nature's most dangerous phenomenon known to man. Overvoltage due to lightning is a very important problem of LV systems. Some lightning flashes damage buildings and a few kill or injure people and animals, either directly or indirectly, by causing fire and explosions. The need for protect...

  7. Avoided losses on LV networks as a result of microgeneration

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Moises [Escola Superior Tecnologia Viseu, Instituto Politecnico Viseu, Campus Politecnico Repeses, 3504-510 Viseu (Portugal); Matos, Manuel A. [INESC Porto, Faculdade de Engenharia da Universidade do Porto, Porto (Portugal)

    2009-04-15

    In the scope of the discussions about microgeneration (and microgrids), the avoided electrical losses are often pointed out as an important value to be credited to those entities. Therefore, methods to assess the impact of microgeneration on losses must be developed in order to support the definition of a suitable regulatory framework for the economic integration of microgeneration on distribution networks. This paper presents an analytical method to quantify the value of avoided losses that microgeneration may produce on LV networks. Intervals of expected avoided losses are used to account for the variation of avoided losses due to the number, size and location of microgenerators, as well as for the kind of load distribution on LV networks. (author)

  8. Impact of pacing on systemic ventricular function in L-transposition of the great arteries.

    Science.gov (United States)

    Hofferberth, Sophie C; Alexander, Mark E; Mah, Douglas Y; Bautista-Hernandez, Victor; del Nido, Pedro J; Fynn-Thompson, Francis

    2016-01-01

    To assess the impact of univentricular versus biventricular pacing (BiVP) on systemic ventricular function in patients with congenitally corrected transposition of the great arteries (ccTGA). We performed a retrospective review of all patients with a diagnosis of ccTGA who underwent pacemaker insertion. From 1993 to 2014, 53 patients were identified from the cardiology database and surgical records. Overall mortality was 7.5% (n = 4). One patient required transplantation and 3 late deaths occurred secondary to end-stage heart failure. Median follow-up was 3.7 years (range, 4 days to 22.5 years). Twenty-five (47%) underwent univentricular pacing only, of these, 8 (32%) developed significant systemic ventricular dysfunction. Twenty-eight (53%) received BiVP, 17 (26%) were upgraded from a dual-chamber system, 11 (21%) received primary BiVP. Fourteen (82%) of the 17 undergoing secondary BiVP demonstrated systemic ventricular dysfunction at the time of pacer upgrade, with 7 (50%) demonstrating improved systemic ventricular function after pacemaker upgrade. Overall, 42 (79%) patients underwent univentricular pacing, with 22 (52%) developing significant systemic ventricular dysfunction. In contrast, the 11 (21%) who received primary BiVP had preserved systemic ventricular function at latest follow-up. Late-onset systemic ventricular dysfunction is a major complication associated with the use of univentricular pacing in patients with ccTGA. All patients with ccTGA who develop heart block should undergo primary biventricular pacing, as this prevents late systemic ventricular dysfunction. Preemptive placement of BiVP leads at the time of anatomical repair or other permanent palliative procedure will facilitate subsequent BiVP should heart block develop. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. Improvement of Left Ventricular Function by Permanent Direct His-Bundle Pacing in a Case with Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Yukiko Sashida, MD

    2006-01-01

    Full Text Available The patient was a 67-year-old female diagnosed with dilated cardiomyopathy. She had chronic atrial fibrillation (AF with bradycardia and low left ventricular function (left ventricular ejection fraction (LVEF 40%. She was admitted for congestive heart failure. She remained New York Heart Association (NYHA functional class III due to AF bradycardia. Pacemaker implantation was necessary for treatment of heart failure and administration of dose intensive β-blockers. As she had normal His-Purkinje activation, we examined the optimal pacing sites. Hemodynamics of His-bundle pacing and biventricular pacing were compared. Pulmonary capillary wedge pressure (PCWP was significantly lower on Hisbundle pacing than right ventricular (RV apical pacing and biventricular pacing (13mmHg, 19mmHg, and 19mmHg, respectively with an almost equal cardiac index. Based on the examination we implanted a permanent pacemaker for Direct His-bundle pacing (DHBP. After the DHBP implantation, the LVEF immediately improved from 40% to 55%, and BNP level decreased from 422 pg/ml to 42 pg/ml. The number of premature ventricular complex (PVC was decreased, and non sustained ventricular tachycardia (NSVT disappeared. Pacing threshold for His-bundle pacing has remained at the same level. His-bundle pacing has been maintained during 27 months and her long-term DHBP can improve cardiac function and the NYHA functional class.

  10. A Dynamic and Heuristic Phase Balancing Method for LV Feeders

    Directory of Open Access Journals (Sweden)

    Samad Taghipour Boroujeni

    2016-01-01

    Full Text Available Due to the single-phase loads and their stochastic behavior, the current in the distribution feeders is not balanced. In addition, the single-phase loads are located in different positions along the LV feeders. So the amount of the unbalanced load and its location affect the feeder losses. An unbalanced load causes the feeder losses and the voltage drop. Because of time-varying behavior of the single-phase loads, phase balancing is a dynamic and combinatorial problem. In this research, a heuristic and dynamic solution for the phase balancing of the LV feeders is proposed. In this method, it is supposed that the loads’ tie could be connected to all phases through a three-phase switch. The aim of the proposed method is to make the feeder conditions as balanced as possible. The amount and the location of single-phase loads are considered in the proposed phase balancing method. Since the proposed method needs no communication interface or no remote controller, it is inexpensive, simple, practical, and robust. Applying this method provides a distributed and dynamic phase balancing control. In addition, the feasibility of reducing the used switches is investigated. The ability of the proposed method in the phase balancing of the LV feeders is approved by carrying out some simulations.

  11. Expanding the Substrate Specificity of Thermoanaerobacter pseudoethanolicus Secondary Alcohol Dehydrogenase by a Dual Site Mutation

    KAUST Repository

    Musa, Musa M.; Bsharat, Odey; Karume, Ibrahim; Vieille, Claire; Takahashi, Masateru; Hamdan, Samir

    2017-01-01

    Here, we report the asymmetric reduction of selected phenyl-ring-containing ketones by various single and dual site mutants of Thermoanaerobacter pseudoethanolicus secondary alcohol dehydrogenase (TeSADH). Further expanding the size of the substrate binding pocket in the mutant W110A/I86A not only allowed substrates of the single mutants W110A and I86A to be accommodated within the expanded active site, but also expanded the enzyme's substrate range to ketones bearing two sterically demanding groups (bulky-bulky ketones), which are not substrates for TeSADH single mutants. We also report the regio- and enantioselective reduction of diketones using W110A/I86A TeSADH and single TeSADH mutants. The double mutant exhibited dual stereopreference generating the Prelog products most of the time and the anti-Prelog products in a few cases.

  12. Expanding the Substrate Specificity of Thermoanaerobacter pseudoethanolicus Secondary Alcohol Dehydrogenase by a Dual Site Mutation

    KAUST Repository

    Musa, Musa M.

    2017-12-14

    Here, we report the asymmetric reduction of selected phenyl-ring-containing ketones by various single and dual site mutants of Thermoanaerobacter pseudoethanolicus secondary alcohol dehydrogenase (TeSADH). Further expanding the size of the substrate binding pocket in the mutant W110A/I86A not only allowed substrates of the single mutants W110A and I86A to be accommodated within the expanded active site, but also expanded the enzyme\\'s substrate range to ketones bearing two sterically demanding groups (bulky-bulky ketones), which are not substrates for TeSADH single mutants. We also report the regio- and enantioselective reduction of diketones using W110A/I86A TeSADH and single TeSADH mutants. The double mutant exhibited dual stereopreference generating the Prelog products most of the time and the anti-Prelog products in a few cases.

  13. Recent developments in cardiac pacing.

    Science.gov (United States)

    Rodak, D J

    1995-10-01

    Indications for cardiac pacing continue to expand. Pacing to improve functional capacity, which is now common, relies on careful patient selection and technical improvements, such as complex software algorithms and diagnostic capabilities.

  14. Envelope Proteins of White Spot Syndrome Virus (WSSV Interact with Litopenaeus vannamei Peritrophin-Like Protein (LvPT.

    Directory of Open Access Journals (Sweden)

    Shijun Xie

    Full Text Available White spot syndrome virus (WSSV is a major pathogen in shrimp cultures. The interactions between viral proteins and their receptors on the surface of cells in a frontier target tissue are crucial for triggering an infection. In this study, a yeast two-hybrid (Y2H library was constructed using cDNA obtained from the stomach and gut of Litopenaeus vannamei, to ascertain the role of envelope proteins in WSSV infection. For this purpose, VP37 was used as the bait in the Y2H library screening. Forty positive clones were detected after screening. The positive clones were analyzed and discriminated, and two clones belonging to the peritrophin family were subsequently confirmed as genuine positive clones. Sequence analysis revealed that both clones could be considered as the same gene, LV-peritrophin (LvPT. Co-immunoprecipitation confirmed the interaction between LvPT and VP37. Further studies in the Y2H system revealed that LvPT could also interact with other WSSV envelope proteins such as VP32, VP38A, VP39B, and VP41A. The distribution of LvPT in tissues revealed that LvPT was mainly expressed in the stomach than in other tissues. In addition, LvPT was found to be a secretory protein, and its chitin-binding ability was also confirmed.

  15. Quantitative analysis of cardiac function: Comparison of electrocardiogram dual gated single photon emission tomography, planar radionuclide ventriculogram and contrast ventriculography in the determination of LV volume and ejection fraction

    Energy Technology Data Exchange (ETDEWEB)

    Ziada, G.; Abdel-Dayem, H.M.; Higazy, E.; Mohamed, M.M.; Bahar, R.; Hayat, N.; Yousof, A.M.

    1987-03-01

    A dual gated tomography (DGT) program for end systolic and end diastolic acquisition and subsequent processing for calculation of LVEF, end diastolic and end systolic volumes (EDV, ESV) has been evaluated in 20 healthy volunteers (25 years-40 years) and 45 patients (25 years-60 years): 20 with ischaemic heart disease and 25 with valvular heart disease (VHD). All had biplane multigated blood pool (MUGA) studies in the 40/sup 0/ LAO projection using in vivo /sup 99m/Tc-R BCs, immediately followed by DG. The results in the patients group were correlated with contrast ventriculography (CV). In the volunteer group, the normal values for LVEF, EDV and ESV measured with DGT were found to be 63%+10%, 91 ml + 6 ml and 30 ml + 6ml and r value for the LVEF=0.91 compared with MUGA. In the IHD group, r values compared with CV were 0.915 and 0.97 for the EDV and ESV and 0.934 for the LVEF. Compared with the MUGA, the r value for LVEF was 0.883. In the VHD group, r values were 0.98 for both the EDV and ESV and 0.948 for the LVEF (P<0.002) compared with CV and 0.789 for the LVEF compared with the MUGA. We feel that DGT is an accurate and reproducible technique for LV function measurements.

  16. Pacing Lead-Induced Granuloma in the Atrium: A Foreign Body Reaction to Polyurethane

    Directory of Open Access Journals (Sweden)

    Shinagawa Yoko

    2013-01-01

    Full Text Available We described a case of an 82-year-old male who presented with a granuloma entrapping the polyurethane-coated pacing lead at the site of contact on the atrium. He had been paced for 8 years without symptoms or signs suggestive of an allergic reaction to the pacemaker system and died from thrombosis of the superior mesenteric artery and heart failure. A histological examination of the nodule showed an incidental granuloma with multinucleated giant cells. No granuloma was found in the heart or the lung.

  17. Estudio de las cualidades inmunoestimulantes de nuevas bacterias probióticas asociadas al cultivo de lv

    OpenAIRE

    Gullian, Mariel; Rodríguez, Jenny

    2002-01-01

    Estudio de las cualidades inmunoestimulantes de nuevas bacterias probióticas asociadas al cultivo de LV Estudio de las cualidades inmunoestimulantes de nuevas bacterias probióticas asociadas al cultivo de LV

  18. Removal of the liquid waste storage tank LV-2 in JRTF. Part 2. Removal works

    International Nuclear Information System (INIS)

    Kanayama, Fumihiko; Hagiya, Kazuaki; Sunaoshi, Mizuho; Muraguchi, Yoshinori; Satomi, Shinichi; Nemoto, Kouichi; Terunuma, Akihiro; Shiraishi, Kunio; Ito, Shinichi

    2011-06-01

    Dismantling activities of components in JAERI's Reprocessing Test Facility (JRTF) started from 1996 as a part of decommissioning of this facility. Removing out of a large liquid waste storage tank LV-2 as a whole tank from the annex building B without cutting in pieces to confirm safety and efficiency of this method started from 2006. After preparatory works, ceiling of LV-2 room was opened, and LV-2 was transferred. Useful data such as manpower, radiation control and waste amount through these works were collected, and work efficiency was analyzed by using of these data. (author)

  19. Hemodynamic stress testing using pacing tachycardia

    International Nuclear Information System (INIS)

    McKay, R.G.; Grossman, W.

    1986-01-01

    A trial pacing was first introduced in 1967 by Sowton and co-workers as a stress test which could be used in the cardiac catheterization laboratory to evaluate patients with schemic heart disease. Sowton noted that artificially increasing the heart rate by pacing the right atrium could usually induce angina in patients with symptomatic coronary artery disease. Since Sowton's original description, numerous investigators have described characteristic pacing-induced electrocardiographic changes, derangements of myocardial lactate metabolism, hemodynamic abnormalities, regional wall abnormalities, and defects in thallium scintigraphy. Although agreement on the overall usefulness of atrial pacing has not been uniform, it is clear that the technique can safely and reliably induce ischemia in most patients with coronary artery disease and that information obtained during the pacing-induced ischemic state can often be helpful in the diagnosis and treatment of the patient's underlying disease

  20. A New Protection System for Islanding Detection in LV Distribution Systems

    Directory of Open Access Journals (Sweden)

    Anna Rita Di Fazio

    2015-04-01

    Full Text Available The growth of penetration of Distributed Generators (DGs is increasing the risk of unwanted islanded operation in Low Voltage (LV distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match between generation and load. In this paper, a new protection system for islanding detection in LV distribution systems is proposed. The classical voltage and frequency relays in the DG interface protections are enriched with an innovative Smart Islanding Detector, which adopts a new passive islanding detection method. The aim is to keep the advantages of the classical relays while overcoming the problem of their limited sensitivity in detecting balanced islands. In the paper, to define the requirements of the anti-islanding protection system, the events causing the islanded operation of the LV distribution systems are firstly identified and classified. Then, referring to proposed protection system, its architecture and operation are described and, eventually, its performance is analyzed and validated by experimental laboratory tests, carried out with a hardware-in-the-loop technique.

  1. Positive pacing in elite IRONMAN triathletes.

    Science.gov (United States)

    Angehrn, Nicole; Rüst, Christoph A.; Nikolaidis, Pantelis T.; Rosemann, Thomas; Knechtle, Beat

    2016-12-31

    Pacing is known to influence athletic performance. For the Ironman triathlon program, a positive pacing strategy, i.e., the continuous decrease of speed over time was recommended. By analyzing split times, we assessed the pacing strategies of the top 100 finishers of the cycling part of 13 Ironman races and of the running part of 11 Ironman races taking place in 2014. Furthermore, sex-associated differences in performance and pacing strategies were calculated. We analyzed 7,687 cycling and 11,894 running split times of 1,392 triathletes (1,263 men, 129 women). Changes in speed were assessed using mixed-effects regression analyses. A continuous decrease in speed was observed during cycling in 10/13 races, and during running in 11/11 races. In 6/13 races, women decreased their speed during cycling significantly more than men. The running part showed no significant difference of changes in speed between the sexes. In summary, in the Ironman races evaluated, a positive pacing strategy was adopted in most races. Women were slower than men in 6/13 cycling races, but there was no difference between men and women in the run splits. Women used the same pacing strategy as men.

  2. Effect of atrial preference pacing on reducing long-term burden of atrial fibrillation:a clinical study

    International Nuclear Information System (INIS)

    Xu Jianfeng; Chen Yueguang; Su Yangang; Zhang Dadong

    2010-01-01

    Objective: To evaluate the clinical effect of atrial preference pacing (APP) on the prevention of paroxysmal atrial fibrillation. Methods: Based on the type of implanted pacemaker, 46 patients with sick sinus syndrome and paroxysmal atrial fibrillation were divided into two groups. Dual-chamber pacemaker equipped with APP function was implanted in patients of group APP (n=21), while conventional dual-chamber pacemaker was implanted in patients of control group (n=25). The patients were followed up for six months, the maximum P wave duration (Pmax), the P wave dispersion (Pd), the structure of heart chambers, the data of automatic mode switch (AMS) and the total burden of atrial fibrillation were estimated,and the results were statistically analyzed and compared between two groups. Results: The basic clinical characteristics of two groups were comparable. After six months pacing, the difference in Pmax between two groups was of no significance (115.0 ± 10.1 ms vs 122.0 ± 11.0 ms, P > 0.05), while the increase of Pd in control group was more obvious than that in group APP (32.7 ± 4.2 ms vs 20.1 ± 5.3 ms, P 0.05), and also no remarkable difference in the left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF) could be found (P > 0.05). Moreover, no significant difference existed between two groups (P > 0.05). After six months pacing,in group APP the frequencies of AMS decreased more sharply (145 ± 37 times vs 327 ± 13 times, P < 0.05), the duration of AMS shortened more apparently (73 ± 15 hours vs 139 ± 28 hours, P < 0.05) and the total burden of atrial fibrillation was alleviated more obviously (13 ± 5% vs 28 ± 6%, P < 0.05) when compared to those in control group. Conclusion: Atrial preference pacing can coordinate the anisotropy of double atrial depolarization, reduce the frequencies of long-term paroxysmal atrial fibrillation, shorten the duration of atrial fibrillation

  3. Smart curtailment for congestion management in LV distribution network

    NARCIS (Netherlands)

    Haque, A. N.M.M.; Rahman, M. T.; Nguyen, P. H.; Bliek, F. W.

    2016-01-01

    The rapid proliferation of distributed energy resources (DERs) leads to capacity challenges, i.e. network congestions, in the low-voltage (LV) distribution networks. A number of strategies are being widely studied to tackle the challenges with direct switching actions such as load shedding or power

  4. Effects of AV delay programming on ventricular resynchronisation: role of radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Siegrist, Patrick T.; Comte, Nathalie; Holzmeister, Johannes; Suetsch, Gabor; Koepfli, Pascal; Namdar, Mehdi; Duru, Firat; Brunckhorst, Corinna; Scharf, Christoph [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2008-08-15

    Optimal atrioventricular delay (AVD) setting for cardiac resynchronisation therapy, i.e. biventricular pacing in patients with heart failure, remains a formidable challenge. Thus, the purpose of this study was to evaluate the effects of different AVD on inter- and intra-ventricular resynchronisation using phase histograms of radionuclide ventriculography (RNV). In 17 consecutive patients (mean age 64 {+-} 6 years), RNV was performed 236 {+-} 350 days after pacemaker implantation for cardiac resynchronisation therapy. Images were acquired during atrial pacing at 80 bpm and during biventricular pacing with AVD ranging from 80 to 160 ms. Inter-ventricular dyssynchrony was measured by the delay between the mean phase angles of the left and right ventricles. Intra-ventricular dyssynchrony was measured by the standard deviation (SD) of left ventricular phase histograms. Left ventricular (LV) ejection fraction (EF) was inversely correlated to LV dyssynchrony (SD of LV phase histogram, R = -0.82, p < 0.0001). However, the increase in LVEF by biventricular pacing (mean +4.4 {+-} 4%) showed only modest correlation to the resulting resynchronisation effect (characterised by a -13 {+-} 8 decrease in LV phase histogram SD, R = -0.38, p < 0.0001). RNV is helpful in optimising pacing parameters for resynchronisation therapy. Varying AVD did not have a major impact on intra- or inter-ventricular resynchronisation. Thus, the benefit of AVD-based LVEF optimisation seems to result from atrioventricular resynchronisation. (orig.)

  5. Role of HIV-2 envelope in Lv2-mediated restriction

    International Nuclear Information System (INIS)

    Reuter, Sandra; Kaumanns, Patrick; Buschhorn, Sabine B.; Dittmar, Matthias T.

    2005-01-01

    We have characterized envelope protein pseudotyped HIV-2 particles derived from two HIV-2 isolates termed prCBL23 and CBL23 in order to define the role of the envelope protein for the Lv2-mediated restriction to infection. Previously, it has been described that the primary isolate prCBL23 is restricted to infection of several human cell types, whereas the T cell line adapted isolate CBL23 is not restricted in these cell types. Molecular cloning of the two isolates revealed that the env and the gag gene are responsible for the observed phenotype and that this restriction is mediated by Lv2, which is distinct from Ref1/Lv1 (Schmitz, C., Marchant, D., Neil, S.J., Aubin, K., Reuter, S., Dittmar, M.T., McKnight, A., Kizhatil, K., Albritton, L.M., 2004. Lv2, a novel postentry restriction, is mediated by both capsid and envelope. J. Virol. 78 (4), 2006-2016). We generated pseudotyped viruses consisting of HIV-2 (ROD-AΔenv-GFP, ROD-AΔenv-RFP, or ROD-AΔenv-REN) and the prCBL23 or CBL23 envelope proteins as well as chimeric proteins between these envelopes. We demonstrate that a single amino acid exchange at position 74 in the surface unit of CBL23-Env confers restriction to infection. This single point mutation causes tighter CD4 binding, resulting in a less efficient fusion into the cytosol of the restricted cell line. Prevention of endosome formation and prevention of endosome acidification enhance infectivity of the restricted particles for GHOST/X4 cells indicating a degradative lysosomal pathway as a cause for the reduced cytosolic entry. The described restriction to infection of the primary isolate prCBL23 is therefore largely caused by an entry defect. A remaining restriction to infection (19-fold) is preserved when endosomal acidification is prevented. This restriction to infection is also dependent on the presence of the point mutation at position 74 (G74E)

  6. Current status of the Citrus leprosis virus (CiLV -C and its vector Brevipalpus phoenicis (Geijskes

    Directory of Open Access Journals (Sweden)

    Guillermo León M

    2012-08-01

    Full Text Available The Citrus leprosis virus CiLV-C is a quarantine disease of economic importance. Over the past 15 years, this disease has spread to several countries of Central and South America. Colombia has about 45,000 hectares of citrus planted with an annual production of 750,000 tonnes. The CiLV-C has only been detected in the departments of Meta, Casanare and recently Tolima. Meta has 4,300 hectares representing 10% of the national cultivated area, and Casanare, where CiLV-C appeared in 2004, has no more than 500 ha planted with citrus. The presence of the Citrus leprosis virus in Colombia could affect the international market for citrus, other crops and ornamental plants with the United States and other countries without the disease. The false spider mite Brevipalpus phoenicis (Geijskes (Acari: Tenuipalpidae is the main vector of the CiLV-C. Disease management is based on control programs of the vector and diminishing host plants. Chemical mite control is expensive, wasteful and generates resistance to different acaricides. This paper provides basic information on CiLV-C and its vector, advances in diagnosis and methods to control the disease and prevention of its spread

  7. How do we perceive activity pacing in rheumatology care?

    DEFF Research Database (Denmark)

    Cuperus, N.; Vliet Vlieland, T.; Brodin, N.

    2015-01-01

    goals of activity pacing, behaviours of activity pacing (the actions people take to meet the goal of activity pacing), strategies to change behaviour in activity pacing (for example goal setting) and contextual factors that should be acknowledged when instructing activity pacing. Besides, topics......-management programs. However, despite its wide endorsement in clinical practice, to date activity pacing is still a poorly understood concept. Objectives: To achieve consensus by means of an international Delphi exercise on the most important aspects of activity pacing as an intervention within non...... for future research on activity pacing were formulated and prioritized. Results: Of the 60 panelists, nearly two third (63%) completed all four Delphi rounds. The panel prioritized 9 goals, 11 behaviours, 9 strategies to change behaviour and 10 contextual factors of activity pacing. These items were...

  8. Feline immunodeficiency virus (FIV, feline leukaemia virus (FeLV and Leishmania sp. in domestic cats in the Midwest of Brazil

    Directory of Open Access Journals (Sweden)

    Daniella Poffo

    Full Text Available ABSTRACT: This search aimed to investigate FIV and FeLV infections in domestic cats, analysing the epidemiological profile of the disease as well as additional infection with Leishmania sp. We evaluated 88 domestic cats for the presence of FIV, FeLV and Leishmania sp. infection. Eleven (12.5% cats were positive for FIV infection, four (4.5% were positive for FeLV, and two were co-infected. However, none was infected with Leishmania sp. The prevalence for FIV infection was higher than FeLV, and those observed in other regions, but no factor was associated with the infection by FIV and FeLV in this study.

  9. Voltage unbalance mitigation in LV networks using three-phase PV systems

    DEFF Research Database (Denmark)

    Garcia Bajo, Cristina; Hashemi Toghroljerdi, Seyedmostafa; Bækhøj Kjær, Søren

    2015-01-01

    In this paper a new method is proposed to mitigate voltage unbalance caused by single-phase solar inverters in low voltage (LV) networks. The method is based on uneven reactive power absorption and injection by three-phase solar inverters. Independent control of each phase is performed to achieve...... this uneven injection. The average values of phase voltages at the connection points of the photovoltaic (PV) inverters are used as the references for the balancing algorithm. Voltage unbalance mitigation is achieved by use of this method in different scenarios with variable three-phase and single......-phase inverters penetration in a realistic LV grid. In addition, the overvoltage is reduced by using this method....

  10. Efficient Control of Energy Storage for Increasing the PV Hosting Capacity of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob

    2016-01-01

    grid is usually limited by overvoltage, and the efficient control of distributed electrical energy storage systems (EESSs) can considerably increase this capacity. In this paper, a new control approach based on the voltage sensitivity analysis is proposed to prevent overvoltage and increase the PV......Photovoltaic (PV) systems are among the renewable sources that electrical energy systems are adopting with increasing frequency. The majority of already-installed PV systems are decentralized units that are usually connected to lowvoltage (LV) distribution grids. The PV hosting capacity of an LV...... hosting capacity of LV grids by determining dynamic set points for EESS management. The method has the effectiveness of central control methods and can effectively decrease the energy storage required for overvoltage prevention, yet it eliminates the need for a broadband and fast communication. The net...

  11. Left and Right Ventricle Leads Switch as a Solution for TWave Oversensing - How a Good Idea Turned Out Bad.

    Science.gov (United States)

    Alzand, Bsn; Phlips, Tje; Willems, R

    2014-05-01

    A 50-year-old male with a CRT defibrillator received inappropriate ICD shocks due to T-wave oversensing. Decreasing the sensitivity to avoid T wave oversensing was not an option due to a suboptimal R-wave sensing amplitude. We decided to re-plug the LV lead in the RV port and the RV lead in the LV port. This however led to intermittent phrenic nerve stimulation due to mandatory bipolar (tip-ring) or unipolar (tip-can) pacing on the LV-lead from the RV port. Re-intervention was necessary with the implantation of an additional pacing/sensing RV lead. A software programmable choice to switch sensing and tachycardia detection from RV to LV lead could be a valuable feature in future CRT devices.

  12. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    Directory of Open Access Journals (Sweden)

    Domenico Santarsiero

    2008-03-01

    Full Text Available The Applanix POS/LV platform in cinematic laser scanner applicationsOn the 11th of march the GEOmedia editorial unit had the pleasure of hosting a technical meeting dedicated to the Applanix LANDMark new Position and Orientation System for Land Vehicles (POS/LVfield test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products and Terenzio Mariani (Sales manager for Italy, helped to test the functionalities of a complete POS/LV system equipped with a laser and an imaging acquisition software installed on board of a SUV.

  13. Temporary emergency pacing-an orphan in district hospitals

    DEFF Research Database (Denmark)

    Gjesdal, Knut; Johansen, Jens Brock; Gadler, Fredrik

    2012-01-01

    This editorial discusses a report on the 1 year experience with temporary pacing, especially in the emergency setting, in several Norwegian district hospitals. The vast majority of the patients received transvenous temporary pacing, and the majority of leads were placed by noncardiologists....... The procedure times were long and complications were frequent. The organization of emergency pacing is discussed, and we suggest that unless qualified physicians can establish transvenous pacing, the patients who need that should be transferred with transcutaneous pacing as back-up during transport...

  14. Recurrent surgical site infection of the spine diagnosed by dual 18F-NaF-bone PET/CT with early-phase scan

    International Nuclear Information System (INIS)

    Shim, Jai-Joon; Lee, Jeong Won; Jeon, Min Hyok; Lee, Sang Mi

    2016-01-01

    We report a case of a 31-year-old man who showed recurrently elevated level of the serum inflammatory marker C-reactive protein (CRP) after spinal operation. He underwent 18 F-flurodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) and dual 18 F-sodium-fluoride ( 18 F-NaF) PET/CT with an additional early-phase scan to find a hidden inflammation focus. Only mildly increased 18 F-FDG was found at the surgical site of T11 spine on 18 F-FDG PET/CT. In contrast, dual 18 F-NaF bone PET/CT with early-phase scan demonstrated focal active inflammation at the surgical site of T11 spine. After a revision operation of the T11 spine, serum CRP level decreased to the normal range without any symptom or sign of inflammation. Inflammatory focus in the surgical site of the spine can be detected with using dual 18 F-NaF bone PET/CT scan with early-phase scan. (orig.)

  15. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    Science.gov (United States)

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  16. Analysis of critical operating conditions for LV distribution networks with microgrids

    Science.gov (United States)

    Zehir, M. A.; Batman, A.; Sonmez, M. A.; Font, A.; Tsiamitros, D.; Stimoniaris, D.; Kollatou, T.; Bagriyanik, M.; Ozdemir, A.; Dialynas, E.

    2016-11-01

    Increase in the penetration of Distributed Generation (DG) in distribution networks, raises the risk of voltage limit violations while contributing to line losses. Especially in low voltage (LV) distribution networks (secondary distribution networks), impacts of active power flows on the bus voltages and on the network losses are more dominant. As network operators must meet regulatory limitations, they have to take into account the most critical operating conditions in their systems. In this study, it is aimed to present the impact of the worst operation cases of LV distribution networks comprising microgrids. Simulation studies are performed on a field data-based virtual test-bed. The simulations are repeated for several cases consisting different microgrid points of connection with different network loading and microgrid supply/demand conditions.

  17. Dual-task related gait changes in individuals with trans-tibial lower extremity amputation.

    Science.gov (United States)

    Hunter, Susan W; Frengopoulos, Courtney; Holmes, Jeffrey; Viana, Ricardo; Payne, Michael W C

    2018-03-01

    The improvement of gait and mobility are major rehabilitation goals following lower extremity amputations. However, when living in the community many daily activities require the multitasking of motor and cognitive tasks. The dual-task paradigm can be used to evaluate the concurrent performance of mobility and cognitive tasks. The purpose of this study was to evaluate the effects of dual-task gait testing in older adults with trans-tibial amputations. Twenty-four people (15 men, mean age ± SD, 62.72 ± 8.59) with trans-tibial amputation walked on an electronic walkway at i) self-selected comfortable pace and ii) self-selected comfortable pace while counting backwards by threes from a number randomly selected between 100 and 150. Cognitive performance, in the form of corrected response rate, was also evaluated as a single-task. The dual-task testing produced poorer performance in velocity (single-task = 58.15 ± 23.16 cm/s, dual-task = 50.92 ± 21.16 cm/s, p = 0.008), cadence (single-task = 76.65 ± 15.84 steps/min, dual-task = 67.85 ± 15.76 steps/min, p = 0.002) and stride time (single-task = 1094 ± 458.28 ms, dual-task = 1241.44 ± 513.73 ms, p = 0.005). Step length, stance time and single limb support time symmetry were also affected, such that less time was spent on the amputated limb during the dual-task testing. Dual-task testing demonstrated interference resulting in a poor performance in both gait and cognitive performance in trans-tibial amputees. Further research is suggested to evaluate the change in cognition-mobility effects over time and the relationship of this value to future adverse events such as falls and successful outcomes such as community ambulation and reintegration. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Viral Determinants of FeLV Infection and Pathogenesis: Lessons Learned from Analysis of a Natural Cohort

    Directory of Open Access Journals (Sweden)

    Laura S. Levy

    2011-09-01

    Full Text Available Detailed analysis has been performed over many years of a geographic and temporal cohort of cats naturally infected with feline leukemia virus (FeLV. Molecular analysis of FeLV present in the diseased tissues and application of those viruses to experimental systems has revealed unique isolates with distinctive disease potential, previously uncharacterized virus-receptor interactions, information about the role of recombinant viruses in disease induction, and novel viral and cellular oncogenes implicated in pathogenesis, among other findings. The studies have contributed to an understanding of the selective forces that lead to predominance of distinctive FeLV isolates and disease outcomes in a natural population.

  19. Effect of short-term rapid ventricular pacing followed by pacing interruption on arterial blood pressure in healthy pigs and pigs with tachycardiomyopathy.

    Science.gov (United States)

    Skrzypczak, P; Zyśko, D; Pasławska, U; Noszczyk-Nowak, A; Janiszewski, A; Gajek, J; Nicpoń, J; Kiczak, L; Bania, J; Zacharski, M; Tomaszek, A; Jankowska, E A; Ponikowski, P; Witkiewicz, W

    2014-01-01

    Ventricular tachycardia may lead to haemodynamic deterioration and, in the case of long term persistence, is associated with the development of tachycardiomyopathy. The effect of ventricular tachycardia on haemodynamics in individuals with tachycardiomyopathy, but being in sinus rhythm has not been studied. Rapid ventricular pacing is a model of ventricular tachycardia. The aim of this study was to determine the effect of rapid ventricular pacing on blood pressure in healthy animals and those with tachycardiomyopathy. A total of 66 animals were studied: 32 in the control group and 34 in the study group. The results of two groups of examinations were compared: the first performed in healthy animals (133 examinations) and the second performed in animals paced for at least one month (77 examinations). Blood pressure measurements were taken during chronic pacing--20 min after onset of general anaesthesia, in baseline conditions (20 min after pacing cessation or 20 min after onset of general anaesthesia in healthy animals) and immediately after short-term rapid pacing. In baseline conditions significantly higher systolic and diastolic blood pressure was found in healthy animals than in those with tachycardiomyopathy. During an event of rapid ventricular pacing, a significant decrease in systolic and diastolic blood pressure was found in both groups of animals. In the group of chronically paced animals the blood pressure was lower just after restarting ventricular pacing than during chronic pacing. Cardiovascular adaptation to ventricular tachycardia develops with the length of its duration. Relapse of ventricular tachycardia leads to a blood pressure decrease more pronounced than during chronic ventricular pacing.

  20. Optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    A non-invasive, contact-less cardiac pacing technology can be a powerful tool in basic cardiac research and in clinics. Currently, electrical pacing is the gold standard for cardiac pacing. Although highly effective in controlling the cardiac function, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its capabilities. Optical pacing of heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids shortcomings in electrical stimulation. Optical coherence tomography has been proved to be an effective technique in non-invasive imaging in vivo with ultrahigh resolution and imaging speed. In the last several years, non-invasive specific optical pacing in animal hearts has been reported in quail, zebrafish, and rabbit models. However, Drosophila Melanogaster, which is a significant model with orthologs of 75% of human disease genes, has rarely been studied concerning their optical pacing in heart. Here, we combined optogenetic control of Drosophila heartbeat with optical coherence microscopy (OCM) technique for the first time. The light-gated cation channel, channelrhodopsin-2 (ChR2) was specifically expressed by transgene as a pacemaker in drosophila heart. By stimulating the pacemaker with 472 nm pulsed laser light at different frequencies, we achieved non-invasive and more specific optical control of the Drosophila heart rhythm, which demonstrates the wide potential of optical pacing for studying cardiac dynamics and development. Imaging capability of our customized OCM system was also involved to observe the pacing effect visually. No tissue damage was found after long exposure to laser pulses, which proved the safety of optogenetic control of Drosophila heart.

  1. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  2. Paleoceanographic Changes Since the Last Glacial as Revealed by Analysis of Alkenone Organic Biomarkers from the Northwest Pacific (Core LV 63-41-2)

    Science.gov (United States)

    Yu, P. S.; Liao, C. J.; Chen, M. T.; Zou, J. J.; Shi, X.; Bosin, A. A.; Gorbarenko, S. A.

    2017-12-01

    Sea surface temperature (SST) records from the subarctic Northwestern (NW) Pacific are ideal for reconstructing regional paleoceanographic changes sensitive to global climate change. Core LV 63-41-2 (52.56°N, 160.00° E; water depth 1924 m) retrieved from a high sedimentation site, in which the interactions of the Bering Sea and the warm water mass from the NW Pacific are highly dynamic. Here we reported high-resolution last glacial alkenone-based records from Core LV 63-41-2. Prior to 27-16 ka BP high glacial C37:4 alkenone concentrations indicate large amount of fresh water influencing the surface water of the NW Pacific with a reaching to the Site LV 63-41-2. We further inferred that during the last glacial the low salinity water may be formed from the ice-melting water on site and/or brought by the surface current from the Bering Sea, and are efficient in producing strong water stratification condition. The stratification weakens vertical mixing of the upper water column, that in turn decreases the nutrients upwelled from deep to the surface therefore causes low productivity of coccolithophorids. During the early Bølling-Allerød (B/A) period, a gradual increasing alkenone-SST and associated with high C37:4 alkenone concentrations, implying that a weakened stratification and much stronger nutrient upwelling of the early B/A period than that of the glacial. The late B/A period is characterized by an abrupt warming with possibly more melting sea ices in the Bering Sea and the coast near the Kamchatka Peninsula. The large amount of fresh water lens formed during the ice melting might have ceased vertical mixing and upwelling in the upper water column as evidenced by a decline of biological productivity of both calcerous and soliceous organism during late B/A. We suggest an early warming and low productivity in the NW Pacific that is coincident with a rapid cooling in most of the Northern Hemisphere high latitudes during the Younger Dryas.

  3. Pacing in Swimming: A Systematic Review.

    Science.gov (United States)

    McGibbon, Katie E; Pyne, D B; Shephard, M E; Thompson, K G

    2018-03-20

    Pacing strategy, or how energy is distributed during exercise, can substantially impact athletic performance and is considered crucial for optimal performance in many sports. This is particularly true in swimming given the highly resistive properties of water and low mechanical efficiency of the swimming action. The aim of this systematic review was to determine the pacing strategies utilised by competitive swimmers in competition and their reproducibility, and to examine the impact of different pacing strategies on kinematic, metabolic and performance variables. This will provide valuable and practical information to coaches and sports science practitioners. The databases Web of Science, Scopus, SPORTDiscus and PubMed were searched for published articles up to 1 August 2017. A total of 23 studies examining pool-based swimming competitions or experimental trials in English-language and peer-reviewed journals were included in this review. In short- and middle-distance swimming events maintenance of swimming velocity is critical, whereas in long-distance events a low lap-to-lap variability and the ability to produce an end spurt in the final lap(s) are key. The most effective strategy in the individual medley (IM) is to conserve energy during the butterfly leg to optimise performance in subsequent legs. The pacing profiles of senior swimmers remain relatively stable irrespective of opponents, competition stage or type, and performance time. Implementing event-specific pacing strategies should benefit the performance of competitive swimmers. Given differences between swimmers, there is a need for greater individualisation when considering pacing strategy selection across distances and strokes.

  4. Management of functional Sprint Fidelis leads at cardiac resynchronization therapy-defibrillator generator replacement: a novel option for preventing inappropriate shocks from lead failure in fragile patients with high risk of sudden death.

    Science.gov (United States)

    Zhu, Dennis W X; Chu, Matthew M; House, Chad M

    2017-12-01

    In patients with a functional Sprint Fidelis lead at generator replacement, the manufacturer recommended to either continue to use the existing lead or replace it with a new lead. For those patients who continue to use a functional Fidelis lead, the risk of inappropriate shocks remains present if the lead fails in the future. We evaluated the feasibility of an alternative approach at the time of cardiac resynchronization therapy-defibrillator (CRT-D) generator replacement in patients with a functional bipolar left ventricular (LV) lead for prevention of inappropriate shocks from future Fidelis lead failure. During the procedure, the pace/sense IS-1 connection pin of the functional Fidelis lead was intentionally inserted into the LV port of the new CRT-D generator, while the existing bipolar LV lead IS-1 connection pin was inserted into the right ventricular (RV) pace/sense port. After such switching, the existing bipolar LV lead was used for functional LV pacing/sensing, while the Fidelis lead was used for functional RV pacing and high voltage shock only and could no longer be used for the purpose of sensing and detecting. This approach precluded oversensing and inappropriate shocks should the functional Fidelis lead fail in the future. Six fragile patients, who were not considered suitable candidates for lead replacement, underwent the alternative approach. During a follow-up of 35 ± 23 months, the CRT-D system functioned normally in five patients. The Fidelis lead fractured in one patient 7 months after generator replacement. The malfunction was detected promptly and the defected lead was replaced. No inappropriate detections or shock was triggered. In CRT-D patients with a functional Fidelis lead and a bipolar LV lead, switching of the Fidelis lead pace/sense IS-1 pin with the bipolar LV lead IS-1 pin at generator replacement did not affect normal system function. This novel approach may be valuable in fragile patients with high risk of sudden death for

  5. Peritrophin-like protein from Litopenaeus vannamei (LvPT) involved in white spot syndrome virus (WSSV) infection in digestive tract challenged with reverse gavage

    Science.gov (United States)

    Xie, Shijun; Li, Fuhua; Zhang, Xiaojun; Zhang, Jiquan; Xiang, Jianhai

    2017-11-01

    The peritrophic membrane plays an important role in the defense system of the arthropod gut. The digestive tract is considered one of the major tissues targeted by white spot syndrome virus (WSSV) in shrimp. In this study, the nucleotide sequence encoding peritrophin-like protein of Litopenaeus vannamei (LvPT) was amplified from a yeast two-hybrid library of L. vannamei. The epitope peptide of LvPT was predicted with the GenScript OptimumAntigen™ design tool. An anti-LvPT polyclonal antibody was produced and shown to specifically bind a band at 27 kDa, identified as LvPT. The LvPT protein was expressed and its concentration determined. LvPT dsRNA (4 μg per shrimp) was used to inhibit LvPT expression in shrimp, and a WSSV challenge experiment was then performed with reverse gavage. The pleopods, stomachs, and guts were collected from the shrimp at 0, 24, 48, and 72 h post-infection (hpi). Viral load quantification showed that the levels of WSSV were significantly lower in the pleopods, stomachs, and guts of shrimp after LvPT dsRNA interference than in those of the controls at 48 and 72 hpi. Our results imply that LvPT plays an important role during WSSV infection of the digestive tract.

  6. The pace of aging: Intrinsic time scales in demography

    Directory of Open Access Journals (Sweden)

    Tomasz Wrycza

    2014-05-01

    Full Text Available Background: The pace of aging is a concept that captures the time-related aspect of aging. It formalizesthe idea of a characteristic life span or intrinsic population time scale. In the rapidly developing field of comparative biodemography, measures that account for inter-speciesdifferences in life span are needed to compare how species age. Objective: We aim to provide a mathematical foundation for the concept of pace. We derive desiredmathematical properties of pace measures and suggest candidates which satisfy these properties. Subsequently, we introduce the concept of pace-standardization, which reveals differences in demographic quantities that are not due to pace. Examples and consequences are discussed. Conclusions: Mean life span (i.e., life expectancy from birth or from maturity is intuitively appealing,theoretically justified, and the most appropriate measure of pace. Pace-standardizationprovides a serviceable method for comparative aging studies to explore differences indemographic patterns of aging across species, and it may considerably alter conclusionsabout the strength of aging.

  7. Application of SPCALC for chemical and thermodynamic speciation of fluids -example for wells LV-4A, LV-11 and LV-13, Las Tres Virgenes geothermal field, BCS; Aplicacion del SPCALC en la especiacion quimica y termodinamica de fluidos: ejemplo del caso de los pozos LV-4A, LV-11 y LV-13, del campo geotermico de Las Tres Virgenes, BCS

    Energy Technology Data Exchange (ETDEWEB)

    Viggiano Guerra, J.C.; Sandoval Medina, F.; Flores Armenta, M.C. [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)]. E-mail: fernando.sandoval@cfe.gob.mx, E-mail: magaly.flores@cfe.gob.mx; Perez, R.J. [Universidad de Calgary (Canada); Gonzalez Partida, E. [Universidad Nacional Autonoma de Mexico, Centro de Geociencias, Mexico, D.F. (Mexico)

    2009-01-15

    SPCALC is an excellent software application providing chemical and multi-phase speciation for geothermal fluids. Recently it was acquired by the Comision Federal de Electricidad (CFE) through a contract with the National Autonomous University of Mexico (UNAM) and the University of Calgary, Canada. Software methodology consists of calculating thermodynamic variables, such as activity (a) and fugacity (f) of chemical species, as well as the saturation indices (log Q/K) of mineral phases of the reservoir. In other words, it models the thermodynamic conditions of the reservoir (pH among other) and simulates the fluid-corrosion rate. This allows the software to foresee scaling and corrosion. In this paper, pervasive fluids in Cretaceous granitic rocks penetrated by wells LV-4A, LV-11 and LV-13 in Las Tres Virgenes geothermal field, BCS, are modeled, starting with chemical analyses. The more important ratios among activities [those which influence the fluid-rock interaction (i.e. {sup a}K{sup +}/{sup a}H{sup +}, {sup a}Ca{sup ++}/{sup a}H{sup +}, {sup a}Na{sup +}/{sup a}H{sup +}, {sup a}Mg{sup ++}/{sup a}H{sup +}) and whose results are the minerals visible under a microscope] are graphed in balance diagrams compatible with the pressure (P) and temperature (T) conditions in the reservoir. Epidote (zoisite) is the mineral found in congruent equilibrium with the system. The main mineral association at those conditions (200-250 degrees Celsius and {approx}18 bar), as observed in the well cuttings, is calcite+illite-quartz{+-}epidote, which is explained by the hydrolithic reactions that form replacement calcite in the presence of CO{sub 2}, thus restricting the formation of epidote and eventually eliminating it. The process enhances the CO{sub 2} molarity in the residual fluid, even up to {sup m}CO{sub 2} 1, which means the CO{sub 2} can be diluted back into fluid and intervene again in the process of calcite formation (2HCO{sub 3}{sup -} + Ca{sup ++} = calcite + H{sub 2}O

  8. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang; Feng, Jianlin; Lloyd, Michael S.; Chen, Ji

    2012-01-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  9. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang [First Affiliated Hospital of Nanjing Medical University, Department of Cardiology, Nanjing, Jiangsu (China); Feng, Jianlin [First Affiliated Hospital of Nanjing Medical University, Department of Nuclear Medicine, Nanjing, Jiangsu (China); Lloyd, Michael S. [Emory University School of Medicine, Division of Cardiology, Atlanta, GA (United States); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-07-15

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  10. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    International Nuclear Information System (INIS)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi; Morikage, Noriyasu; Sano, Yuichi; Suga, Kazuyoshi

    2013-01-01

    Background: Dual-energy perfusion CT (DE p CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE p CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE p CT using a 64-slice dual-source CT. DE p CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V 120 ), 1-15 HU (V 15 ), 1-10 HU (V 10 ), and 1-5 HU (V 5 ). Each relative ratio per V 120 was expressed as the %V 15 , %V 10 , and %V 5 . Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V 15 , V 10 , V 5 , %V 15 , %V 10 , and %V 5 were also significantly higher than those without IPC (P = 0.001). %V 5 had a better correlation with D-dimer (r = 0.30, P p CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE

  11. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  12. Web Tools: Keeping Learners on Pace

    Science.gov (United States)

    Kosloski, Mickey

    2016-01-01

    One of the greatest challenges in teaching technology and engineering is pacing. Some students grasp new technological concepts quickly, while others need repetition and may struggle to keep pace. This poses an obstacle for the technology and engineering teacher, and is particularly true when teaching students to build a website. However, there…

  13. Procedure times, complication rates, and survival times associated with single-chamber versus dual-chamber pacemaker implantation in dogs with clinical signs of bradyarrhythmia: 54 cases (2004-2009).

    Science.gov (United States)

    Genovese, David W; Estrada, Amara H; Maisenbacher, Herbert W; Heatwole, Bonnie A; Powell, Melanie A

    2013-01-15

    To compare procedure times and major and minor complication rates associated with single-chamber versus dual-chamber pacemaker implantation and with 1-lead, 2-lead, and 3-lead pacemaker implantation in dogs with clinical signs of bradyarrhythmia. Retrospective case series. 54 dogs that underwent pacemaker implantation because of clinical signs of bradyarrhythmia. Medical records of dogs that received pacemakers between July 2004 and December 2009 were reviewed for information regarding signalment, diagnosis, pacemaker implantation, pacemaker type, complications, and survival time. Analyses were performed to determine significant differences in anesthesia time, procedure time, and outcome for dogs on the basis of pacing mode and number of pacing leads. 28 of 54 (51.9%) dogs received single-chamber pacemakers and 26 (48.1%) received dual-chamber pacemakers. Mean ± SD procedural time was significantly longer for patients with dual-chamber pacemakers (133.5 ± 51.3 minutes) than for patients with single-chamber pacemakers (94.9 ± 37.0 minutes), and procedure time increased significantly as the number of leads increased (1 lead, 102.3 ± 51.1 minutes; 2 leads, 114.9 ± 24.8 minutes; 3 leads, 158.2 ± 8.5 minutes). Rates of major and minor complications were not significantly different between dogs that received single-chamber pacemakers and those that received dual-chamber pacemakers or among dogs grouped on the basis of the number of pacing leads placed. Although dual-chamber pacemaker implantation did result in increased procedural and anesthesia times, compared with single-chamber pacemaker implantation, this did not result in a higher complication rate.

  14. Drift of IBL LV current and its consequence in IBL distortion

    CERN Document Server

    The ATLAS collaboration

    2015-01-01

    The low voltage (LV) current of the IBL modules had been stable since the beginning of the Run2 until the middle of September 2015, but it has been unstable since then (Figure 1). A clear relation is observed between the current rise-up and the total radiation doze (TID) increase, which is considered to be the TID effect reported in . A shutdown of more than 29 hour on October 6 recovered the current largely (Figure 2). With the change of the LV current, the temperature of IBL modules also changes (Figure 3). The change of the thermo-mechanical condition of the IBL resulted in the change of the IBL distortion magnitude, and a clear relation between the module temperature and the distortion magnitude is observed (Figure 4). Through the duration presented in this series of plots, the cooling set temperature of the IBL was kept at -10℃.

  15. Effects of simultaneous and optimized sequential cardiac resynchronization therapy on myocardial oxidative metabolism and efficiency.

    Science.gov (United States)

    Christenson, Stuart D; Chareonthaitawee, Panithaya; Burnes, John E; Hill, Michael R S; Kemp, Brad J; Khandheria, Bijoy K; Hayes, David L; Gibbons, Raymond J

    2008-02-01

    Cardiac resynchronization therapy (CRT) can improve left ventricular (LV) hemodynamics and function. Recent data suggest the energy cost of such improvement is favorable. The effects of sequential CRT on myocardial oxidative metabolism (MVO(2)) and efficiency have not been previously assessed. Eight patients with NYHA class III heart failure were studied 196 +/- 180 days after CRT implant. Dynamic [(11)C]acetate positron emission tomography (PET) and echocardiography were performed after 1 hour of: 1) AAI pacing, 2) simultaneous CRT, and 3) sequential CRT. MVO(2) was calculated using the monoexponential clearance rate of [(11)C]acetate (k(mono)). Myocardial efficiency was expressed in terms of the work metabolic index (WMI). P values represent overall significance from repeated measures analysis. Global LV and right ventricular (RV) MVO(2) were not significantly different between pacing modes, but the septal/lateral MVO(2) ratio differed significantly with the change in pacing mode (AAI pacing = 0.696 +/- 0.094 min(-1), simultaneous CRT = 0.975 +/- 0.143 min(-1), and sequential CRT = 0.938 +/- 0.189 min(-1); overall P = 0.001). Stroke volume index (SVI) (AAI pacing = 26.7 +/- 10.4 mL/m(2), simultaneous CRT = 30.6 +/- 11.2 mL/m(2), sequential CRT = 33.5 +/- 12.2 mL/m(2); overall P simultaneous CRT = 4.29 +/- 1.72 mmHg*mL/m(2)*10(6), sequential CRT = 4.79 +/- 1.92 mmHg*mL/m(2)*10(6); overall P = 0.002) also differed between pacing modes. Compared with simultaneous CRT, additional changes in septal/lateral MVO(2), SVI, and WMI with sequential CRT were not statistically significant on post hoc analysis. In this small selected population, CRT increases LV SVI without increasing MVO(2), resulting in improved myocardial efficiency. Additional improvements in LV work, oxidative metabolism, and efficiency from simultaneous to sequential CRT were not significant.

  16. Interneta sociālie tīkli draugiem.lv, mammam/tetiem.lv un twitter.com kā reklāmas nesēji Latvijā (2009.gads)

    OpenAIRE

    Vismane, Inese

    2010-01-01

    Maģistra darba tēma ir „Interneta sociālie tīkli draugiem.lv, mammam/tetiem.lv un twitter.com kā reklāmas nesēji Latvijā (2009.gads)”. Darba mērķis ir izpētīt Latvijas interneta sociālo tīklu vidi kā potenciāli augošu un reklāmai piemērotu, kā arī izpētīt pamanāmākos reklāmas gadījumus šajos portālos. Teorijas daļā tiek apskatīta Web 2.0 ēra, interneta reklāmas un sociālo mediju mārketinga īpatnības, sociālo tīklu fenomens un teorijas, Latvijas reklāmas tirgus un auditorija, kā arī sociāl...

  17. 42 CFR 460.90 - PACE benefits under Medicare and Medicaid.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE benefits under Medicare and Medicaid. 460.90 Section 460.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... FOR THE ELDERLY (PACE) PACE Services § 460.90 PACE benefits under Medicare and Medicaid. If a Medicare...

  18. Technical summary of the Performance Assessment Calculational Exercises for 1990 (PACE-90)

    International Nuclear Information System (INIS)

    Barnard, R.W.; Dockery, H.A.

    1991-06-01

    A Performance Assessment Calculational Exercise for 1990 (PACE-90) was coordinated by the Yucca Mountain Site Characterization Project Office for a total-system performance-assessment problem. The primary objectives of the exercise were to develop performance-assessment computational capabilities of the Yucca Mountain Project participates and to aid in identifying critical elements and processes associated with the calculation. The problem defined for PACE-90 was simulation of a ''nominal case'' groundwater flow and transport of a selected group of radionuclides through a portion of Yucca Mountain. Both 1-D and 2-D calculations were run for a modeling period of 100,000 years. The nuclides used, 99 Tc, 135 Cs, 129 I, and 237 Np, were representative of ''classes'' of long-lived nuclides expected to be present in the waste inventory. Movement of the radionuclides was simulated through a detailed hydrostratigraphy developed from Yucca Mountain data specifically for this exercise. The results showed that, for the specified conditions with the conceptual models used in the problem, no radioactive contamination reached the water table, 230 m below the repository. However, due to the unavailability of sufficient site-specific data, the results of this exercise cannot be considered a comprehensive total-system- performance assessment of the Yucca Mountain site as a high-level- waste repository. 46 refs., 94 figs., 19 tabs

  19. Pacing: a concept analysis of the chronic pain intervention.

    Science.gov (United States)

    Jamieson-Lega, Kathryn; Berry, Robyn; Brown, Cary A

    2013-01-01

    The intervention of pacing is regularly recommended for chronic pain patients. However, pacing is poorly defined and appears to be interpreted in varying, potentially contradictory manners within the field of chronic pain. This conceptual lack of clarity has implications for effective service delivery and for researchers' ability to conduct rigorous study. An examination of the background literature demonstrates that while pacing is often one part of a multidisciplinary pain management program, outcome research is hindered by a lack of a clear and shared definition of this currently ill-defined construct. To conduct a formal concept analysis of the term 'pacing'. A standardized concept analysis process (including literature scoping to identify all uses of the concept, analysis to determine defining attributes of the concept and identification of model, borderline and contrary cases) was used to determine what the concept of pacing does and does not represent within the current evidence base. A conceptual model including the core attributes of action, time, balance, learning and self-management emerged. From these attributes, an evidence-based definition for pacing was composed and distributed to stakeholders for review. After consideration of stakeholder feedback, the emergent definition of pacing was finalized as follows: "Pacing is an active self-management strategy whereby individuals learn to balance time spent on activity and rest for the purpose of achieving increased function and participation in meaningful activities". The findings of the present concept analysis will help to standardize the use and definition of the term pacing across disciplines for the purposes of both pain management and research.

  20. Lv Peng and his Chinese Art History in Operation, since 1986’

    Directory of Open Access Journals (Sweden)

    Joshua Gong

    2014-06-01

    Full Text Available Lv Peng is one of the most influential contemporary Chinese art historians, who began publishing his work in 1986 and introduced various innovative approaches and methods to the field. Even though his work gained momentum in the field, his totalising and continually-revised publication scheme have come under incessant criticism from friends and rivals alike. This article is an attempt at surveying Lv Peng’s oeuvre, while testifying to the value of his art history writings by making his various approaches more legible and systematic. His most popular publications as well as a few projects that are still in progress will be analysed for a more comprehensive understanding of his operational art history.

  1. Relationship between echocardiographic LV mass and ECG based left ventricular voltages in an adolescent population: related or random?

    Science.gov (United States)

    Czosek, Richard J; Cnota, James F; Knilans, Timothy K; Pratt, Jesse; Guerrier, Karine; Anderson, Jeffrey B

    2014-09-01

    In attempts to detect diseases that may place adolescents at risk for sudden death, some have advocated for population-based screening. Controversy exists over electrocardiography (ECG) screening due to the lack of specificity, cost, and detrimental effects of false positive or extraneous outcomes. Analyze the relationship between precordial lead voltage on ECG and left ventricle (LV) mass by echocardiogram in adolescent athletes. Retrospective cohort analysis of a prospectively obtained population of self-identified adolescent athletes during sports screening with ECG and echocardiogram. Correlation between ECG LV voltages (R wave in V6 [RV6] and S wave in lead V1 [SV1]) was compared to echocardiogram-based measurements of left ventricular mass. Potential effects on ECG voltages by body anthropometrics, including weight, body mass index (BMI), and body surface area were analyzed, and ECG voltages indexed to BMI were compared to LV mass indices to analyze for improved correlation. A total of 659 adolescents enrolled in this study (64% male). The mean age was 15.4 years (14-18). The correlations between LV mass and RV6, SV1, and RV6 + SV1 were all less than 0.20. The false positive rate for abnormal voltages was relatively high (5.5%) but improved if abnormal voltages in both RV6 and SV1 were mandated simultaneously (0%). Indexing ECG voltages to BMI significantly improved correlation to LV mass, though false positive findings were increased (12.9%). There is poor correlation between ECG precordial voltages and echocardiographic LV mass. This relationship is modified by BMI. This finding may contribute to the poor ECG screening characteristics. ©2014 Wiley Periodicals, Inc.

  2. Effect of atrial pacing on phase analysis in patients with the Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Magosaki, Nobuhisa; Hiroe, Michiaki; Kasanuki, Hiroshi; Ohnishi, Satoshi; Tanaka, Etsuko; Horie, Toshinobu; Kusakabe, Kiyoko; Kondo, Mizuka; Hirosawa, Koshichiro

    1984-01-01

    Phase analysis of ECG-gated radionuclide ventriculography was performed during sinus rhythm and atrial pacing for 11 patients with the Wolff-Parkinson-White (WPW) syndrome. During sinus rhythm, phase analysis demonstrated abnormal early-emptying segments reflecting preexcitation in six of the 11 patients. In the remaining five patients, the precise site of abnormal early-emptying could not be detected. Atrial pacing increased the degree of pre-exicitation, and abnormal early-emptying segments became clear in all patients. Our study demonstrated the utility of atrial pacing in performing phase analysis for patients with the WPW syndrome. Seven patients had abnormal early-emptying segments; four of them with ECG type A, in the left ventricle, and three of them with ECG type B, in the right ventricle. These results were consistent with results of the body surface and electrophysiologic mapping. In patients with posterior septal accessory pathways, phase analysis suggested probable laterality of the accessory pathway. (author)

  3. Distributed generation in the Dutch LV network - self-supporting residential area

    NARCIS (Netherlands)

    Mes, M.; Vanalme, G.M.A.; Myrzik, J.M.A.; Bongaerts, M.; Verbong, G.P.J.; Kling, W.L.

    2008-01-01

    A self-supporting residential area is seen as an alternative operational approach of power supply in low voltage (LV) networks. The intention of the new approach is to exploit the advantages of distributed generation (DG) and avoid the difficulties, that come with DG when implemented in the

  4. Hematological findings and factors associated with feline leukemia virus (FeLV and feline immunodeficiency virus (FIV positivity in cats from southern Brazil

    Directory of Open Access Journals (Sweden)

    Fernanda V.A. da Costa

    Full Text Available ABSTRACT: Using a retrospective study, 493 cats tested for FeLV and FIV were selected for analysis of the association between hematologic findings and positivity at immunoassay test. Individual and hematologic variables were assessed considering the influence of results using univariate and multivariate logistic regression analysis. Out 153 of the 493 cats were positive for FeLV (31%, 50 were positive for FIV (10.1% and 22 were positive for both FIV and FeLV (4.4%. Multivariate analysis detected significant associations between FeLV infection and age below 1 year (p=0.01, age from 1 to 10 years (p=0.03, and crossbreed (p=0.04. Male cats were more likely to be FIV-positive (p=0.002. Regarding hematological changes, FeLV-positive cats have higher odds to anemia, leukopenia and lymphopenia than FeLV-negative cats. FIV-positive cats are more likely to have anemia than negative. Identification of associated factors related to animal status and correlation of hematological disorders with infection by retroviruses in cats could be useful for detecting these retroviral diseases in cats.

  5. Litopenaeus vannamei sterile-alpha and armadillo motif containing protein (LvSARM is involved in regulation of Penaeidins and antilipopolysaccharide factors.

    Directory of Open Access Journals (Sweden)

    Pei-Hui Wang

    Full Text Available The Toll-like receptor (TLR-mediated NF-κB pathway is tightly controlled because overactivation may result in severe damage to the host, such as in the case of chronic inflammatory diseases and cancer. In mammals, sterile-alpha and armadillo motif-containing protein (SARM plays an important role in negatively regulating this pathway. While Caenorhabditis elegans SARM is crucial for an efficient immune response against bacterial and fungal infections, it is still unknown whether Drosophila SARM participates in immune responses. Here, Litopenaeus vannamei SARM (LvSARM was cloned and functionally characterized. LvSARM shared signature domains with and exhibited significant similarities to mammalian SARM. Real-time quantitative PCR analysis indicated that the expression of LvSARM was responsive to Vibrio alginolyticus and white spot syndrome virus (WSSV infections in the hemocyte, gill, hepatopancreas and intestine. In Drosophila S2 cells, LvSARM was widely distributed in the cytoplasm and could significantly inhibit the promoters of the NF-κB pathway-controlled antimicrobial peptide genes (AMPs. Silencing of LvSARM using dsRNA-mediated RNA interference increased the expression levels of Penaeidins and antilipopolysaccharide factors, which are L.vannamei AMPs, and increased the mortality rate after V. alginolyticus infection. Taken together, our results reveal that LvSARM may be a novel component of the shrimp Toll pathway that negatively regulates shrimp AMPs, particularly Penaeidins and antilipopolysaccharide factors.

  6. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  7. Pace of work stabilising, but not in all sectors

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2003-01-01

    The Netherlands had the highest level of work pace in Europe but this position has levelled off in the last five years. There appears to be a general trend towards a decline in work pace. However, different sectors show varying trends, with work pace on the rise again in the education, health and

  8. Understanding Counterfactuality: A Review of Experimental Evidence for the Dual Meaning of Counterfactuals

    Science.gov (United States)

    Nieuwland, Mante S.

    2016-01-01

    Abstract Cognitive and linguistic theories of counterfactual language comprehension assume that counterfactuals convey a dual meaning. Subjunctive‐counterfactual conditionals (e.g., ‘If Tom had studied hard, he would have passed the test’) express a supposition while implying the factual state of affairs (Tom has not studied hard and failed). The question of how counterfactual dual meaning plays out during language processing is currently gaining interest in psycholinguistics. Whereas numerous studies using offline measures of language processing consistently support counterfactual dual meaning, evidence coming from online studies is less conclusive. Here, we review the available studies that examine online counterfactual language comprehension through behavioural measurement (self‐paced reading times, eye‐tracking) and neuroimaging (electroencephalography, functional magnetic resonance imaging). While we argue that these studies do not offer direct evidence for the online computation of counterfactual dual meaning, they provide valuable information about the way counterfactual meaning unfolds in time and influences successive information processing. Further advances in research on counterfactual comprehension require more specific predictions about how counterfactual dual meaning impacts incremental sentence processing. PMID:27512408

  9. Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV-S3, HV-S3A and HV-S3B Exhaust Systems

    Energy Technology Data Exchange (ETDEWEB)

    Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-18

    Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 μm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

  10. Pace studying worldwide coke production

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Pace Consultants Inc., Houston, has started a multiclient study of world-wide petroleum coke production, examining environmental initiatives and eventually forecasting prices of fuel grade coke. Pace expects coker expansions, increased operating severity, and reduced cycle times to boost coke supply to more than 50 million metric tons/year in 2000, compared with 39.7 million metric tons in 1992. Increased supply and tightened environmental rules in countries consuming large amounts of petroleum coke will be the main factors affecting coke markets. The paper discusses coke quality and the Japanese market

  11. Spanish Pacemaker Registry. Thirteenth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2015).

    Science.gov (United States)

    Pombo Jiménez, Marta; Cano Pérez, Óscar; Fidalgo Andrés, María Luisa; Lorente Carreño, Diego; Coma Samartín, Raúl

    2016-12-01

    We describe the results of the analysis of the devices implanted and conveyed to the Spanish Pacemaker Registry in 2015. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. We received information from 111 hospitals, with a total of 12 555 cards, representing 32.1% of all the estimated activity. The use of conventional generators and resynchronization devices was 820 and 73 units per million population, respectively. The mean age of the patients receiving an implantation was 77.7 years, and more than 50% of the devices were implanted in patients over 80 years of age. Overall, 58.6% of the implants and 58.8% of the replacements were performed in men. All of the endocardial leads employed were bipolar, 81.5% had an active fixation system, and 16.5% were compatible with magnetic resonance. Although dual chamber sequential pacing continues to be more widespread, pacing with VVI/R mode is used because up to 23.8% of the patients with sinus node disease are in sinus rhythm, as are 24.1% of those with atrioventricular block. The total use of pacemaker generators in Spain has increased by about 5% with respect to 2014. The majority of the leads implanted are of active fixation, and less than 20% are protected from magnetic resonance. The factors directly related to the selection of pacing mode are age and sex. In around 20% of patients, the choice of the pacing mode could be improved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Zygotic LvBMP5-8 is required for skeletal patterning and for left-right but not dorsal-ventral specification in the sea urchin embryo.

    Science.gov (United States)

    Piacentino, Michael L; Chung, Oliver; Ramachandran, Janani; Zuch, Daniel T; Yu, Jia; Conaway, Evan A; Reyna, Arlene E; Bradham, Cynthia A

    2016-04-01

    Skeletal patterning in the sea urchin embryo requires coordinated signaling between the pattern-dictating ectoderm and the skeletogenic primary mesenchyme cells (PMCs); recent studies have begun to uncover the molecular basis for this process. Using an unbiased RNA-Seq-based screen, we have previously identified the TGF-ß superfamily ligand, LvBMP5-8, as a skeletal patterning gene in Lytechinus variegatus embryos. This result is surprising, since both BMP5-8 and BMP2/4 ligands have been implicated in sea urchin dorsal-ventral (DV) and left-right (LR) axis specification. Here, we demonstrate that zygotic LvBMP5-8 is required for normal skeletal patterning on the left side, as well as for normal PMC positioning during gastrulation. Zygotic LvBMP5-8 is required for expression of the left-side marker soxE, suggesting that LvBMP5-8 is required for left-side specification. Interestingly, we also find that LvBMP5-8 knockdown suppresses serotonergic neurogenesis on the left side. While LvBMP5-8 overexpression is sufficient to dorsalize embryos, we find that zygotic LvBMP5-8 is not required for normal DV specification or development. In addition, ectopic LvBMP5-8 does not dorsalize LvBMP2/4 morphant embryos, indicating that, in the absence of BMP2/4, BMP5-8 is insufficient to specify dorsal. Taken together, our data demonstrate that zygotic LvBMP5-8 signaling is essential for left-side specification, and for normal left-side skeletal and neural patterning, but not for DV specification. Thus, while both BMP2/4 and BMP5-8 regulate LR axis specification, BMP2/4 but not zygotic BMP5-8 regulates DV axis specification in sea urchin embryos. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. PACE and the Federal Housing Finance Agency (FHFA)

    Energy Technology Data Exchange (ETDEWEB)

    Zimring, Mark; Fuller, Merrian

    2010-03-17

    The FHFA regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On June 18, 2009, James B. Lockhart III, then Director of FHFA, released a letter expressing concern about the negative impact of energy loan tax assessment programs (ELTAPs) - also known as Property Assessed Clean Energy (PACE) programs - on both the housing finance system and homeowner program participants. Subsequently, a number of PACE proponents responded to the concerns laid out in the FHFA letter. In early Fall 2009, word circulated that FHFA was planning to follow its June letter with guidance to other agencies, possibly including Fannie Mae and Freddie Mac, discouraging them from buying loans on properties subject to PACE-type assessment liens. This triggered a second round of stakeholder letters, several of which were addressed to President Obama. On October 18, 2009, the White House, in what some believe was an attempt to obviate the need for FHFA guidance, released a Policy Framework for PACE Financing Programs that outlined best practices guidance for homeowner and lender protection. As of February 2010, FHFA and the GSEs have agreed to monitor PACE programs and work with stakeholders and the Administration to consider additional guidance beyond the Policy Framework and to collect more information on PACE program efficacy and risks. A summary of the communications timeline and highlights of the communications are provided.

  14. Comparison of pacing algorithms to avoid unnecessary ventricular pacing in patients with sick sinus node syndrome: a single-centre, observational, parallel study.

    Science.gov (United States)

    Poghosyan, Hermine R; Jamalyan, Smbat V

    2012-10-01

    Reduction of unnecessary ventricular pacing (uVP) is an essential component in the treatment strategy in any pacing population in general. The aim of this study was to evaluate the efficacy of different algorithms to reduce uVP in an adult population with sick sinus syndrome (SSS) treated outside of clinical trials. Evaluation of the relationship between different types of pacing algorithms and clinical outcomes is also provided. This was a single-centre, observational, parallel study, based on retrospective analysis of the Arrhythmology Cardiology Center of Armenia electronic clinical database. This study evaluated atrial pacing percentage (AP%), ventricular pacing percentage (VP%), and the incidence of atrial high rate episodes in 56 patients with SSS using three different pacing strategies: managed VP, search atrioventricular (AV), and fixed long AV. We did not find statistically significant differences in the amount of VP between the groups. Although the atrial high rate percentage (AHR%) tended to be higher in the fixed long AV group, this difference was not statistically significant. Mean VP% and AP% were similar in all three groups. In our study, all three programmed strategies produced the same mean AP% and VP%, and were equally efficient in uVP reduction. There was no relationship between chosen algorithms and the incidence of pacemaker syndrome, hospitalizations, or change in New York Heart Association class. The percentage of AHR was not associated with pacing strategy or co-morbidities but showed borderline correlation with left atrial size.

  15. Coordinated control to mitigate over voltage and under voltage in LV networks

    NARCIS (Netherlands)

    Viyathukattuva Mohamed Ali, M.M.; Nguyen, H.P.; Cobben, J.F.G.

    2016-01-01

    Increasing penetration of distributed renewable energy resources (DRES) and smart loads into the LV network lead to new power quality challenges. Important power quality challenges are overvoltage and undervoltage. A number of solutions are already developed to mitigate these voltage variations. In

  16. Development of tools to manage the operational monitoring and pre-design of the NPP-LV cycle

    International Nuclear Information System (INIS)

    Perusquia, R.; Arredondo S, C.; Hernandez M, J. L.; Montes T, J. L.; Castillo M, A.; Ortiz S, J. J.

    2015-09-01

    This paper presents the development of tools to facilitate the management so much, the operational monitoring of boiling water reactors (BWR) of the nuclear power plant of Laguna Verde (NPP-LV) through independent codes, and how to carry out the static calculations corresponding to process of optimized pre-design of the reference cycle next to current cycle. The progress and preliminary results obtained with the program SACal, developed at Instituto Nacional de Investigaciones Nucleares (ININ), central tool to achieve provide a management platform of the operational monitoring and pre-design of NPP-LV cycle are also described. The reached preliminary advances directed to get an Analysis center and automated design of fuel assembly cells are also presented, which together with centers or similar modules related with the fuel reloads form the key part to meet the targets set for the realization of a Management Platform of Nuclear Fuel of the NPP-LV. (Author)

  17. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study.

    Science.gov (United States)

    Ricci, Renato P; Botto, Giovanni Luca; Bénézet, Juan M; Nielsen, Jens Cosedis; De Roy, Luc; Piot, Olivier; Quesada, Aurelio; Quaglione, Raffaele; Vaccari, Diego; Mangoni, Lorenza; Grammatico, Andrea; Kozák, Milan

    2015-11-01

    Pacing in the right ventricle can cause a variety of detrimental effects, including atrial tachyarrhythmias (atrial tachycardia [AT]/atrial fibrillation [AF]). The purpose of this study was to evaluate the incidence and predictors of persistent AT/AF in patients with long-term exposure to ventricular pacing. In a multicenter international trial, 605 patients (age 75 ± 11 years, 240 women) referred for replacement of an implanted pacemaker or implantable cardioverter-defibrillator (ICD), with a history of high-percentage (>40%) ventricular pacing, were randomly allocated to standard dual-chamber pacing or managed ventricular pacing (MVP), a pacing modality that minimizes ventricular pacing. The main end-point of this secondary analysis of the PreFER MVP randomized study was persistent AT/AF, defined as ≥7 consecutive days with AT/AF or AT/AF interrupted by atrial cardioversion or AT/AF present during 2 consecutive follow-up visits. Persistent AT/AF was observed in 71 patients (11.7%) after 2 years of follow-up. At multivariable Cox regression analysis, prior AT/AF (hazard ratio [HR] 2.85, 95% confidence interval [CI] 1.20-6.22, P = .017) and ventricular pacing percentage, estimated in the first 3 months, ≥10% (HR 3.24, 95% 95% CI 1.13-9.31, P = .029) were independent predictors for persistent AT/AF. MVP was associated with persistent AT/AF risk (HR 3.41, 95% 95% CI 1.10-10.6, P = .024) in the subgroup of patients with baseline long PR interval (PR >230 ms) but not in the whole population. In pacemaker and ICD replacement patients, a high percentage of ventricular pacing is associated with higher risk of persistent AT/AF. Use of algorithms that minimize right ventricular pacing may benefit patients with normal spontaneous AV conduction but should be evaluated with caution in patients with long PR interval. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. Development of porcine model of chronic tachycardia-induced cardiomyopathy.

    Science.gov (United States)

    Paslawska, Urszula; Gajek, Jacek; Kiczak, Liliana; Noszczyk-Nowak, Agnieszka; Skrzypczak, Piotr; Bania, Jacek; Tomaszek, Alicja; Zacharski, Maciej; Sambor, Izabela; Dziegiel, Piotr; Zysko, Dorota; Banasiak, Waldemar; Jankowska, Ewa A; Ponikowski, Piotr

    2011-11-17

    There are few experimental models of heart failure (HF) in large animals, despite structural and functional similarities to human myocardium. We have developed a porcine model of chronic tachycardia-induced cardiomyopathy. Homogenous siblings of White Large breed swine (n=6) underwent continuous right ventricular (RV) pacing at 170 bpm; 2 subjects served as controls. In the course of RV pacing, animals developed a clinical picture of HF and were presented for euthanasia at subsequent stages: mild, moderate and end-stage HF. Left ventricle (LV) sections were analyzed histologically and relative ANP, BNP, phospholamban and sarcoplasmic reticulum calcium ATPase 2a transcript levels in LV were quantified by real time RT-PCR. In the course of RV pacing, animals demonstrated reduced exercise capacity (time of running until being dyspnoeic: 6.6 ± 0.5 vs. 2.4 ± 1.4 min), LV dilatation (LVEDD: 4.9 ± 0.4 vs. 6.7 ± 0.4 cm), impaired LV systolic function (LVEF: 69 ± 8 vs. 32 ± 7 %), (all baseline vs. before euthanasia, all p<0.001). LV tissues from animals with moderate and end-stage HF demonstrated local foci of interstitial fibrosis, congestion, cardiomyocyte hypertrophy and atrophy, which was not detected in controls and mild HF animals. The up-regulation of ANP and BNP and a reduction in a ratio of sarcoplasmic reticulum calcium ATPase 2a and phospholamban in failing myocardium were observed as compared to controls. In pigs, chronic RV pacing at relatively low rate can be used as an experimental model of HF, as it results in a gradual deterioration of exercise tolerance accompanied by myocardial remodeling confirmed at subcellular level. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Molecular Level Control Through Dual Site Participation Using Bimetallic Catalysts - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    d' Itri, Julie, L.; Kovalchuk, Vladimir, I.

    2010-02-08

    The overall goal of this research program was to explore the hypothesis that it is possible to design a bimetallic surface such that each metal catalyzes different elementary reaction steps in an overall reaction pathway. A corollary to this hypothesis is that the different ensemble size requirements for an elementary reaction step can be used to force an elementary reaction step to occur on only one of the metals. The research program involved a combination of materials synthesis, chemical kinetics experiments, spectroscopic studies and computational investigations. The major outcome of this research program was the development and dissemination of the Dual Site Model, for which chlorocarbon reactions in the presence of hydrogen were used as model systems.

  20. Social Interaction in Self-Paced Distance Education

    Science.gov (United States)

    Anderson, Terry; Upton, Lorne; Dron, Jon; Malone, Judi; Poelhuber, Bruno

    2015-01-01

    In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions…

  1. PACE and the Medicare+Choice risk-adjusted payment model.

    Science.gov (United States)

    Temkin-Greener, H; Meiners, M R; Gruenberg, L

    2001-01-01

    This paper investigates the impact of the Medicare principal inpatient diagnostic cost group (PIP-DCG) payment model on the Program of All-Inclusive Care for the Elderly (PACE). Currently, more than 6,000 Medicare beneficiaries who are nursing home certifiable receive care from PACE, a program poised for expansion under the Balanced Budget Act of 1997. Overall, our analysis suggests that the application of the PIP-DCG model to the PACE program would reduce Medicare payments to PACE, on average, by 38%. The PIP-DCG payment model bases its risk adjustment on inpatient diagnoses and does not capture adequately the risk of caring for a population with functional impairments.

  2. Gait performance is not influenced by working memory when walking at a self-selected pace.

    Science.gov (United States)

    Grubaugh, Jordan; Rhea, Christopher K

    2014-02-01

    Gait performance exhibits patterns within the stride-to-stride variability that can be indexed using detrended fluctuation analysis (DFA). Previous work employing DFA has shown that gait patterns can be influenced by constraints, such as natural aging or disease, and they are informative regarding a person's functional ability. Many activities of daily living require concurrent performance in the cognitive and gait domains; specifically working memory is commonly engaged while walking, which is considered dual-tasking. It is unknown if taxing working memory while walking influences gait performance as assessed by DFA. This study used a dual-tasking paradigm to determine if performance decrements are observed in gait or working memory when performed concurrently. Healthy young participants (N = 16) performed a working memory task (automated operation span task) and a gait task (walking at a self-selected speed on a treadmill) in single- and dual-task conditions. A second dual-task condition (reading while walking) was included to control for visual attention, but also introduced a task that taxed working memory over the long term. All trials involving gait lasted at least 10 min. Performance in the working memory task was indexed using five dependent variables (absolute score, partial score, speed error, accuracy error, and math error), while gait performance was indexed by quantifying the mean, standard deviation, and DFA α of the stride interval time series. Two multivariate analyses of variance (one for gait and one for working memory) were used to examine performance in the single- and dual-task conditions. No differences were observed in any of the gait or working memory dependent variables as a function of task condition. The results suggest the locomotor system is adaptive enough to complete a working memory task without compromising gait performance when walking at a self-selected pace.

  3. Pacing in Olympic track races: competitive tactics versus best performance strategy.

    Science.gov (United States)

    Thiel, Christian; Foster, Carl; Banzer, Winfried; De Koning, Jos

    2012-01-01

    The purpose of this study was to describe pacing strategies in the 800 to 10,000-m Olympic finals. We asked 1) if Olympic finals differed from World Records, 2) how variable the pace was, 3) whether runners faced catastrophic events, and 4) for the winning strategy. Publically available data from the Beijing 2008 Olympic Games gathered by four transponder antennae under the 400-m track were analysed to extract descriptors of pacing strategies. Individual pacing patterns of 133 finalists were visualised using speed by distance plots. Six of eight plots differed from the patterns reported for World Records. The coefficient of running speed variation was 3.6-11.4%. In the long distance finals, runners varied their pace every 100 m by a mean 1.6-2.7%. Runners who were 'dropped' from the field achieved a stable running speed and displayed an endspurt. Top contenders used variable pacing strategies to separate themselves from the field. All races were decided during the final lap. Olympic track finalists employ pacing strategies which are different from World Record patterns. The observed micro- and macro-variations of pace may have implications for training programmes. Dropping off the pace of the leading group is an active step, and the result of interactive psychophysiological decision making.

  4. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christoph J., E-mail: c.jensen@contilia.d [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Jochims, Markus [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Hunold, Peter; Forsting, Michael; Barkhausen, Joerg [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany); Sabin, Georg V.; Bruder, Oliver [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Schlosser, Thomas [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany)

    2010-06-15

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 {+-} 8% vs. 64 {+-} 8%, p = 0.47; EDV 136 {+-} 36 ml vs. 138 {+-} 35 ml, p = 0.66; ESV 52 {+-} 21 ml vs. 52 {+-} 22 ml, p = 0.61; SV 83 {+-} 22 ml vs. 87 {+-} 19 ml, p = 0.22; CO 5.4 {+-} 0.9 l/min vs. 5.7 {+-} 1.2 l/min, p = 0.09, LVM 132 {+-} 33 g vs. 132 {+-} 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 {+-} 8% vs. 62 {+-} 9%; SV 73 {+-} 17 ml vs. 81 {+-} 15 ml; CO 5.7 {+-} 1.2 l/min vs. 5.0 {+-} 0.8 l/min; ESV 52 {+-} 27 ml vs. 57 {+-} 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 {+-} 31 g vs. 132 {+-} 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  5. Quantifying grain shape with MorpheoLV: A case study using Holocene glacial marine sediments

    Science.gov (United States)

    Charpentier, Isabelle; Staszyc, Alicia B.; Wellner, Julia S.; Alejandro, Vanessa

    2017-06-01

    As demonstrated in earlier works, quantitative grain shape analysis has revealed to be a strong proxy for determining sediment transport history and depositional environments. MorpheoLV, devoted to the calculation of roughness coefficients from pictures of unique clastic sediment grains using Fourier analysis, drives computations for a collection of samples of grain images. This process may be applied to sedimentary deposits assuming core/interval/image archives for the storage of samples collected along depth. This study uses a 25.8 m jumbo piston core, NBP1203 JPC36, taken from a 100 m thick sedimentary drift deposit from Perseverance Drift on the northern Antarctic Peninsula continental shelf. Changes in ocean and ice conditions throughout the Holocene recorded in this sedimentary archive can be assessed by studying grain shape, grain texture, and other proxies. Ninety six intervals were sampled and a total of 2319 individual particle images were used. Microtextures of individual grains observed by SEM show a very high abundance of authigenically precipitated silica that obscures the original grain shape. Grain roughness, computed along depth with MorpheoLV, only shows small variation confirming the qualitative observation deduced from the SEM. Despite this, trends can be seen confirming the reliability of MorpheoLV as a tool for quantitative grain shape analysis.

  6. Quantifying grain shape with MorpheoLV: A case study using Holocene glacial marine sediments

    Directory of Open Access Journals (Sweden)

    Charpentier Isabelle

    2017-01-01

    Full Text Available As demonstrated in earlier works, quantitative grain shape analysis has revealed to be a strong proxy for determining sediment transport history and depositional environments. MorpheoLV, devoted to the calculation of roughness coefficients from pictures of unique clastic sediment grains using Fourier analysis, drives computations for a collection of samples of grain images. This process may be applied to sedimentary deposits assuming core/interval/image archives for the storage of samples collected along depth. This study uses a 25.8 m jumbo piston core, NBP1203 JPC36, taken from a ~100 m thick sedimentary drift deposit from Perseverance Drift on the northern Antarctic Peninsula continental shelf. Changes in ocean and ice conditions throughout the Holocene recorded in this sedimentary archive can be assessed by studying grain shape, grain texture, and other proxies. Ninety six intervals were sampled and a total of 2319 individual particle images were used. Microtextures of individual grains observed by SEM show a very high abundance of authigenically precipitated silica that obscures the original grain shape. Grain roughness, computed along depth with MorpheoLV, only shows small variation confirming the qualitative observation deduced from the SEM. Despite this, trends can be seen confirming the reliability of MorpheoLV as a tool for quantitative grain shape analysis.

  7. CAMAC interface module for PACE ADC system

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, C G; Mischke, R E [Los Alamos Scientific Lab., N.Mex. (USA); Scott, D T

    1977-03-15

    This report describes a CAMAC module designed to buffer and transfer data from the Tennelec multiplexed ADC system called PACE to a computer. It can be operated in either of two modes: as an eight-deep, first-in-first-out (FIFO) circular buffer, or in channel mode with a single buffer reserved for each PACE channel.

  8. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Feng, Jianlin; Zhou, Yanli; Cao, Kejiang; Lloyd, Michael S; Chen, Ji

    2012-07-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4%) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI.

  9. Dopant site location in dual-implanted GaP using (111) planar channeling

    International Nuclear Information System (INIS)

    Parikh, N.R.; Kao, C.T.; Lee, D.R.; Muse, J.; Swanson, M.L.; Venkatasubramanian, R.; Timmons, M.

    1990-01-01

    Previous studies have indicated that dual implantation can efficiently introduce group IV dopant onto selected sub-lattice sites in III--V compound semiconductors, thus enhancing electrical activation. The authors have studied this phenomenon in GaP using Rutherford Backscattering Spectroscopy (RBS) to determine the lattice location of Sn atoms. The authors used single crystals of GaP (100) which had been implanted at 400 degrees C with 120 Sn + following previously implanted 69 Ga + or 31 P + . Energies were selected for equivalent projected ranges, and all species were implanted with doses of 1 x 10 15 atoms/cm 2 . Asymmetry in the angular scan of the {111} planar channel was then used to determine the sub-lattice location of the implanted Sn. RBS results indicated that for all implants Sn atoms were substituting Ga and P sites equally. However, Hall effect measurements gave p type conduction for GaP implanted with Sn alone, while those with prior implants of Ga or P resulted in n-type conduction. RBS and Hall effect results are explained by a vacancy complex model

  10. Comparable cerebral oxygenation patterns in younger and older adults during dual-task walking with increasing load

    Directory of Open Access Journals (Sweden)

    Sarah A. Fraser

    2016-10-01

    Full Text Available The neuroimaging literature on dual-task gait clearly demonstrates increased prefrontal cortex (PFC involvement when performing a cognitive task while walking. However, findings from direct comparisons of the cerebral oxygenation patterns of younger (YA and older (OA adults during dual-task walking are mixed and it is unclear how YA and OA respond to increasing cognitive load (difficulty while walking. This functional near infra-red (fNIRS study examined cerebral oxygenation of YA and OA during self-paced dual-task treadmill walking at two different levels of cognitive load (auditory n-back. Changes in accuracy (% as well as oxygenated (HbO and deoxygenated (HbR hemoglobin were examined. For the HbO and HbR measures, eight regions of interest (ROIs were assessed: the anterior and posterior dorsolateral and ventrolateral PFC (aDLPFC, pDLPFC, aVLPFC, pVLPFC in each hemisphere. Nineteen YA (M = 21.83 yrs and 14 OA (M = 66.85 yrs walked at a self-selected pace while performing auditory 1-back and 2-back tasks. Walking alone (single motor: SM and performing the cognitive tasks alone (single cognitive: SC were compared to dual-task walking (DT = SM + SC. In the behavioural data, participants were more accurate in the lowest level of load (1-back compared to the highest (2-back; p ˂ .001. YA were more accurate than OA overall (p = .009, and particularly in the 2-back task (p = .048. In the fNIRS data, both younger and older adults had task effects (SM < DT in specific ROIs for ∆HbO (3 YA, 1 OA and ∆HbR (7 YA, 8 OA. After controlling for walk speed differences, direct comparisons between YA and OA did not reveal significant age differences, but did reveal a difficulty effect in HbO in the left aDLPFC (p = .028 and significant task effects (SM < DT in HbR for 6 of the 8 ROIs. Findings suggest that YA and OA respond similarly to manipulations of cognitive load when walking on a treadmill at a self-selected pace.

  11. In hypertrophic cardiomyopathy reduction of relative resting myocardial blood flow is related to late enhancement, T2-signal and LV wall thickness.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available To quantify resting myocardial blood flow (MBF in the left ventricular (LV wall of HCM patients and to determine the relationship to important parameters of disease: LV wall thickness, late gadolinium enhancement (LGE, T2-signal abnormalities (dark and bright signal, LV outflow tract obstruction and age.Seventy patients with proven HCM underwent cardiac MRI. Absolute and relative resting MBF were calculated from cardiac perfusion MRI by using the Fermi function model. The relationship between relative MBF and LV wall thickness, T2-signal abnormalities (T2 dark and T2 bright signal, LGE, age and LV outflow gradient as determined by echocardiography was determined using simple and multiple linear regression analysis. Categories of reduced and elevated perfusion in relation to non- or mildly affected reference segments were defined, and T2-signal characteristics and extent as well as pattern of LGE were examined. Statistical testing included linear and logistic regression analysis, unpaired t-test, odds ratios, and Fisher's exact test.804 segments in 70 patients were included in the analysis. In a simple linear regression model LV wall thickness (p<0.001, extent of LGE (p<0.001, presence of edema, defined as focal T2 bright signal (p<0.001, T2 dark signal (p<0.001 and age (p = 0.032 correlated inversely with relative resting MBF. The LV outflow gradient did not show any effect on resting perfusion (p = 0.901. Multiple linear regression analysis revealed that LGE (p<0.001, edema (p = 0.026 and T2 dark signal (p = 0.019 were independent predictors of relative resting MBF. Segments with reduced resting perfusion demonstrated different LGE patterns compared to segments with elevated resting perfusion.In HCM resting MBF is significantly reduced depending on LV wall thickness, extent of LGE, focal T2 signal abnormalities and age. Furthermore, different patterns of perfusion in HCM patients have been defined, which may represent different stages of

  12. Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Matsudaira, Masamichi; Hisada, Kinichi; Kanayama, Sugako; Yoneyama, Tatsuya; Nakajima, Kenichi; Taki, Junichi; Tonami, Norihisa; Nekolla, Stephan G.

    2005-01-01

    Dual-isotope simultaneous acquisition single-photon emission computed tomography (DISA SPECT) with 18 F-fluorodeoxyglucose (FDG) and 99m Tc-sestamibi appears attractive for the detection of viable myocardium because it permits simultaneous assessment of glucose utilisation and perfusion. Another potential benefit of this approach is that the measurement of left ventricular (LV) function may be possible by ECG gating. The aim of this study was to test the hypothesis that both myocardial viability and LV function can be assessed by a single ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT study, based on comparison with 18 F-FDG/ 13 N-ammonia positron emission tomography (PET) and magnetic resonance imaging (MRI) as reference techniques. Thirty-three patients with prior myocardial infarction underwent ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT and 18 F-FDG/ 13 N-ammonia PET on a single day. Of these, 25 patients also underwent cine-MRI to assess LV function. The LV myocardium was divided into nine regions, and each region was classified as viable or scar using a semiquantitative visual scoring system as well as quantitative analysis. The global and regional LV function measured by gated SPECT was compared with the results of MRI. There was good agreement in respect of viability (90-96%, κ0.74-0.85) between DISA SPECT and PET by either visual or quantitative analysis. Furthermore, although both global and regional LV function measured by gated SPECT agreed with those by MRI, 99m Tc-sestamibi showed a closer correlation with MRI than did 18 F-FDG. In conclusion, ECG-gated DISA SPECT provides information on myocardial viability, as well as global and regional LV function, similar to that obtained by PET and MRI. (orig.)

  13. Acumulación/eliminación de oxitetraciclina en el camarón blanco, lv y su residualidad en dietas artificiales

    OpenAIRE

    Montoya, Nelson; Reyes, Eduardo

    2002-01-01

    Acumulación/eliminación de oxitetraciclina en el camarón blanco, LV y su residualidad en dietas artificiales Acumulación/eliminación de oxitetraciclina en el camarón blanco, LV y su residualidad en dietas artificiales

  14. Chymase inhibition prevents fibronectin and myofibrillar loss and improves cardiomyocyte function and LV torsion angle in dogs with isolated mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Chen, Yuanwen; Killingsworth, Cheryl; Gladden, James D; Shi, Ke; Zheng, Junying; Powell, Pamela C; Walcott, Greg; Ahmed, Mustafa I; Gupta, Himanshu; Desai, Ravi; Wei, Chih-Chang; Hase, Naoki; Kobayashi, Tsunefumi; Sabri, Abdelkarim; Granzier, Henk; Denney, Thomas; Tillson, Michael; Dillon, A Ray; Husain, Ahsan; Dell'italia, Louis J

    2010-10-12

    The left ventricular (LV) dilatation of isolated mitral regurgitation (MR) is associated with an increase in chymase and a decrease in interstitial collagen and extracellular matrix. In addition to profibrotic effects, chymase has significant antifibrotic actions because it activates matrix metalloproteinases and kallikrein and degrades fibronectin. Thus, we hypothesize that chymase inhibitor (CI) will attenuate extracellular matrix loss and LV remodeling in MR. We studied dogs with 4 months of untreated MR (MR; n=9) or MR treated with CI (MR+CI; n=8). Cine MRI demonstrated a >40% increase in LV end-diastolic volume in both groups, consistent with a failure of CI to improve a 25% decrease in interstitial collagen in MR. However, LV cardiomyocyte fractional shortening was decreased in MR versus normal dogs (3.71±0.24% versus 4.81±0.31%; P<0.05) and normalized in MR+CI dogs (4.85±0.44%). MRI with tissue tagging demonstrated an increase in LV torsion angle in MR+CI versus MR dogs. CI normalized the significant decrease in fibronectin and FAK phosphorylation and prevented cardiomyocyte myofibrillar degeneration in MR dogs. In addition, total titin and its stiffer isoform were increased in the LV epicardium and paralleled the changes in fibronectin and FAK phosphorylation in MR+CI dogs. These results suggest that chymase disrupts cell surface-fibronectin connections and FAK phosphorylation that can adversely affect cardiomyocyte myofibrillar structure and function. The greater effect of CI on epicardial versus endocardial titin and noncollagen cell surface proteins may be responsible for the increase in torsion angle in chronic MR.

  15. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  16. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    Directory of Open Access Journals (Sweden)

    Domenico Santarsiero

    2008-03-01

    field test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products and Terenzio Mariani (Sales manager for Italy, helped to test the functionalities of a complete POS/LV system equipped with a laser and an imaging acquisition software installed on board of a SUV.

  17. Evaluation of Left Ventricular Diastolic Dysfunction with Early Systolic Dysfunction Using Two-Dimensional Speckle Tracking Echocardiography in Canine Heart Failure Model.

    Science.gov (United States)

    Wu, Wei-Chun; Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Tang, Yue; Wang, Hao

    2016-04-01

    This study evaluated the role of two-dimensional speckle tracking echocardiography (2DSTE) for predicting left ventricular (LV) diastolic dysfunction in pacing-induced canine heart failure. Pacing systems were implanted in 8 adult mongrel dogs, and continuous rapid right ventricular pacing (RVP, 240 beats/min) was maintained for 2 weeks. The obtained measurements from 2DSTE included global strain rate during early diastole (SRe) and during late diastole (SRa) in the longitudinal (L-SRe, L-SRa), circumferential (C-SRe, C-SRa), and radial directions (R-SRe, R-SRa). Changes in heart morphology were observed by light microscopy and transmission electron microscopy at 2 weeks. The onset of LV diastolic dysfunction with early systolic dysfunction occurred 3 days after RVP initiation. Most of the strain rate imaging indices were altered at 1 or 3 days after RVP onset and continued to worsen until heart failure developed. Light and transmission electron microscopy showed myocardial vacuolar degeneration and mitochondrial swelling in the left ventricular at 2 weeks after RVP onset. Pearson's correlation analysis revealed that parameters of conventional echocardiography and 2DSTE showed moderate correlation with LV pressure parameters, including E/Esep' (r = 0.58, P echocardiography and strain rate imaging could effectively predict LV diastolic dysfunction (area under the curve: E/Esep' 0.78; L-SRe 0.84; E/L-SRe 0.80; R-SRe 0.80). 2DSTE was a sensitive and accurate technique that could be used for predicting LV diastolic dysfunction in canine heart failure model. © 2015, Wiley Periodicals, Inc.

  18. Resistance to RadLV-induced leukemia: non-participation of splenic natural killer cells

    International Nuclear Information System (INIS)

    St-Pierre, Y.; Hugo, P.; Lemieux, S.; Lussier, G.; Potworowski, E.F.

    1988-01-01

    The phenotypic expression of genetically determined resistance to radiation leukemia virus (RadLV)-induced leukemia in mice has been shown to reside in the bone marrow. Because the bone marrow contains precursors of natural killer (NK) cells, known to play a role in retrovirally induced infections, and because these cells have been suggested as participating in resistance to radiation-induced leukemia, it was pertinent to establish whether their levels differed in strains of mice susceptible and resistant to leukemia. We therefore tested splenic NK cell levels in C57BL/Ka (susceptible) and B10.A(5R) (resistant) mice before viral inoculation, immediately after viral inoculation, and throughout the preleukemic period and showed that they were not different. This indicates that splenic NK cell levels have no bearing on the resistance to RadLV-induced leukemia and that other immune or non-immune mechanisms must be sought

  19. Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation.

    Science.gov (United States)

    Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A

    2015-06-01

    The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Pacing a data transfer operation between compute nodes on a parallel computer

    Science.gov (United States)

    Blocksome, Michael A [Rochester, MN

    2011-09-13

    Methods, systems, and products are disclosed for pacing a data transfer between compute nodes on a parallel computer that include: transferring, by an origin compute node, a chunk of an application message to a target compute node; sending, by the origin compute node, a pacing request to a target direct memory access (`DMA`) engine on the target compute node using a remote get DMA operation; determining, by the origin compute node, whether a pacing response to the pacing request has been received from the target DMA engine; and transferring, by the origin compute node, a next chunk of the application message if the pacing response to the pacing request has been received from the target DMA engine.

  1. Ischemic Stroke with Cardiac Pacemaker Implantation: Comparison of Physiological and Ventricular Pacing Modes.

    Science.gov (United States)

    Kato, Yuji; Hayashi, Takeshi; Kato, Ritsushi; Tanahashi, Norio; Takao, Masaki

    2017-09-01

    The clinical characteristics of ischemic stroke in patients with a pacemaker (PM) are not well understood. Forty-six ischemic stroke patients with a PM were investigated retrospectively, and the impact of different pacing modes was compared. The patients were divided into a physiological pacing group (n = 22) and a ventricular pacing group (n = 24). The prevalence of atrial fibrillation (AF) was significantly higher in the ventricular pacing group (36% versus 75%; P = .008). The mean left atrial dimension was relatively large in the ventricular pacing group than in the physiological pacing group (44.5 ± 6.7 mm versus 39.1 ± 8.5 mm, respectively; P = .071). Twenty-four percent of the patients were receiving anticoagulants, whereas 41% of the patients were receiving antiplatelet drugs. Cardioembolism was the most common stroke subtype in both groups. Although there was no statistically significant difference, neurological severity on admission was higher in the ventricular pacing group than in the physiological pacing group (P = .061). Functional outcomes, excluding patients with transient ischemic attack or prior stroke, significantly declined in the ventricular pacing group compared with the physiological pacing group (P = .044). The avoidance of the ventricular pacing mode may result in improved clinical outcomes. In patients without persistent AF, it may be important to select physiological pacing instead of ventricular pacing to decrease potential stroke severity. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Information-Quality based LV-Grid-Monitoring Framework and its Application to Power-Quality Control

    DEFF Research Database (Denmark)

    Findrik, Mislav; Kristensen, Thomas le Fevre; Hinterhofer, Thomas

    2015-01-01

    The integration of unpredictable renewable energy sources into the low voltage (LV) power grid results in new challenges when it comes to ensuring power quality in the electrical grid. Addressing this problem requires control of not only the secondary substation but also control of flexible assets...... inside the LV grid. In this paper we investigate how the flexibility information of such assets can be accessed by the controller using heterogeneous off-the-shelf communication networks. To achieve this we develop an adaptive monitoring framework, through which the controller can subscribe to the assets......' flexibility information through an API. We define an information quality metric making the monitoring framework able to adapt information access strategies to ensure the information is made available to the controller with the highest possible information quality. To evaluate the monitoring framework...

  3. Correlation of trabeculae and papillary muscles with clinical and cardiac characteristics and impact on CMR measures of LV anatomy and function

    NARCIS (Netherlands)

    Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L T F; Salton, Carol J.; Blease, Susan J.; Yeon, Susan B.; Breeuwer, Marcel; O'Donnell, Christopher J.; Manning, Warren J.

    2012-01-01

    Objectives: The goal of this study was to assess the relationship of left ventricular (LV) trabeculae and papillary muscles (TPM) with clinical characteristics in a community-based, free-living adult cohort and to determine the effect of TPM on quantitative measures of LV volume, mass, and ejection

  4. MoMuLV-ts-1: A Unique Mouse Model of Retrovirus-Induced Lymphoma Transmitted by Breast Milk

    Directory of Open Access Journals (Sweden)

    J. Chakraborty

    2011-01-01

    Full Text Available Our laboratory has developed a murine model of lymphoma via breast milk transmission of MoMuLV-ts-1 (Moloney murine leukemia virus-temperature sensitive mutant-1. Uninfected offspring suckled from infected surrogate mothers become infected and develop lymphoma. Multiple gene integration sites of ts-1 into the infected mouse genome including tacc3, aurka, ndel1, tpx2, p53, and rhamm were identified, and mRNA expressions were quantitated. These genes produce centrosomal proteins, which may be involved in abnormal chromosomal segregation leading to aneuploidy or multiploidy, thus causing lymphoma. Since there is no report to date on this retroviral model leading to centrosomal abnormality, and causing lymphoma development, this is a valuable and unique model to study the centrosomal involvement in lymphomagenesis.

  5. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Bak, So Hyeon; Jeon, Hae Jeong; Ko, Sung Min; Yang, Hyun Suk; Hwang, Hweung Kon; Song, Meong Gun

    2012-01-01

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV (8.5 mL, P < 0

  6. Leadless Cardiac Pacemakers: Current status of a modern approach in pacing

    Directory of Open Access Journals (Sweden)

    Skevos Sideris

    2017-11-01

    Full Text Available Since the first transvenous pacemaker implantation, which took place 50 years ago, important progress has been achieved in pacing technology. Consequently, at present, more than 700,000 pacemakers are implanted annually worldwide. However, conventional pacemakers' implantation has a non-negligible risk of periprocedural and long-term complications associated with the transvenous leads and pacemaker pocket. Recently, leadless pacing systems have emerged as a therapeutic alternative to conventional pacing systems that provide therapy for patients with bradyarrhythmias, while eliminating potential transvenous lead- and pacemaker pocket-related complications. Initial studies have demonstrated favorable efficacy and safety of currently developed leadless pacing systems, compared to transvenous pacemakers. In the present paper, we review the current evidence and highlight the advantages and disadvantages of this novel technology. New technological advances may allow the next generation of leadless pacemakers to further expand, thereby offering a wireless cardiac pacing in future. Keywords: cardiac pacing, pacemaker, leadless pacemaker, bradycardia

  7. PACE: Proactively Secure Accumulo with Cryptographic Enforcement

    Science.gov (United States)

    2017-05-27

    will be replaced with the values from the decrypted destination field. PACE encrypts data using AES and supports the following modes: CTR, CFB, CBC, OFB...2) Searchable Encryption : PACE also support searching for encrypted data. This is done using AES in SIV mode [11] to provide deterministic encryption ...row ”Alphabet”), then the search term is encrypted deterministically, and that term is searched on the server. Because AES does not preserve the

  8. Factors explaining voluntary participation in PACE-Vaquita

    OpenAIRE

    Sara Avila

    2011-01-01

    Vaquita marina, a small species of porpoise endemic to the Northern Gulf of California in Mexico, is the world’s most endangered cetacean species. With the purpose of preserving vaquita, the Mexican government launched PACE-Vaquita in 2008. This voluntary program offers an innovative schedule of compensations: as in a payment for conservation program, PACE-Vaquita compensates for temporary reductions in fishing reductions in fishing effort; as in a program to accelerate technology adoption,PA...

  9. Experimental infection of Tilapia Lake Virus (TiLV) in Nile tilapia (Oreochromis niloticus) and red tilapia (Oreochromis spp.).

    Science.gov (United States)

    Tattiyapong, Puntanat; Dachavichitlead, Worawan; Surachetpong, Win

    2017-08-01

    Since 2015, a novel orthomyxo-like virus, tilapia lake virus (TiLV) has been associated with outbreaks of disease and massive mortality of cultured Nile and red tilapia (Oreochromis niloticus and Oreochromis spp., respectively) in Thailand. In this study, TiLV was isolated from field samples and propagated in the permissive E-11 cell line, with cytopathic effect (CPE) development within 3-5days post-inoculation. Electron micrographs of infected E-11 cells and fish tissues confirmed the rounded, enveloped virions of 60 to 80nm with characteristics very similar to those of Orthomyxoviridae. In vivo challenge studies showed that high mortality in Nile (86%) and red tilapia (66%) occurred within 4-12days post-infection. The virus was re-isolated from challenged fish tissues in the permissive cell line, and PCR analysis confirmed TiLV as a causative pathogen. The distinct histopathology of challenged fish included massive degeneration and inflammatory cell infiltration in the liver and brain as well as the presence of eosinophilic intracytoplasmic inclusions in hepatocytes and splenic cells. Our results fulfilled Koch's postulates and confirmed that TiLV is an etiologic agent of mass mortality of tilapia in Thailand. The emergence of this virus in many countries has helped increase awareness that it is a potential threat to tilapia aquacultured in Thailand, Asia, and worldwide. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Development of conductor feedthrough module of LV electrical penetration assembly for research reactors

    International Nuclear Information System (INIS)

    Luo Zhiyuan; Wang Guangjin; Zhou Bin

    2007-01-01

    A LV electrical penetration assembly with perfusion sealing conductor feedthrough module was developed, which can be used for the connection of internal and external cables through the wall of the research reactor workshop. The LV electrical penetration assembly was combined with several independent modules. The maintenance and replacement of the assembly can be easily done in service. The sealing of conductor feedthrough module was achieved with the perfusion of self-extinguishing epoxy. The leakage between the conductor feedthrough module and the end plate module was blocked with rubber rings. The result of the leakage test and the electrical performance test for the samples of conductor feedthrough module satisfied the requirement of research reactor. The structure of the new electrical penetration assembly is simple and compact. It can be manufactured with mature technology and cost low price. The performance of the assembly is steady. It can be used widely in research reactors. (authors)

  11. LV reverse remodeling imparted by aortic valve replacement for severe aortic stenosis; is it durable? A cardiovascular MRI study sponsored by the American Heart Association

    Directory of Open Access Journals (Sweden)

    Caruppannan Ketheswaram

    2011-04-01

    Full Text Available Abstract Background In patients with severe aortic stenosis (AS, long-term data tracking surgically induced effects of afterload reduction on reverse LV remodeling are not available. Echocardiographic data is available short term, but in limited fashion beyond one year. Cardiovascular MRI (CMR offers the ability to serially track changes in LV metrics with small numbers due to its inherent high spatial resolution and low variability. Hypothesis We hypothesize that changes in LV structure and function following aortic valve replacement (AVR are detectable by CMR and once triggered by AVR, continue for an extended period. Methods Tweny-four patients of which ten (67 ± 12 years, 6 female with severe, but compensated AS underwent CMR pre-AVR, 6 months, 1 year and up to 4 years post-AVR. 3D LV mass index, volumetrics, LV geometry, and EF were measured. Results All patients survived AVR and underwent CMR 4 serial CMR's. LVMI markedly decreased by 6 months (157 ± 42 to 134 ± 32 g/m2, p 2. Similarly, EF increased pre to post-AVR (55 ± 22 to 65 ± 11%,(p 2. LV stroke volume increased rapidly from pre to post-AVR (40 ± 11 to 44 ± 7 ml, p Conclusion After initial beneficial effects imparted by AVR in severe AS patients, there are, as expected, marked improvements in LV reverse remodeling. Via CMR, surgically induced benefits to LV structure and function are durable and, unexpectedly express continued, albeit markedly incomplete improvement through 4 years post-AVR concordant with sustained improved clinical status. This supports down-regulation of both mRNA and MMP activity acutely with robust suppression long term.

  12. New approaches to determine fatigue in elite athletes during intensified training: Resting metabolic rate and pacing profile.

    Directory of Open Access Journals (Sweden)

    Amy L Woods

    Full Text Available Elite rowers complete a high volume of training across a number of modalities to prepare for competition, including periods of intensified load, which may lead to fatigue and short-term performance decrements. As yet, the influence of substantial fatigue on resting metabolic rate (RMR and exercise regulation (pacing, and their subsequent utility as monitoring parameters, has not been explicitly investigated in elite endurance athletes.Ten National-level rowers completed a four-week period of intensified training. RMR, body composition and energy intake were assessed PRE and POST the four-week period using indirect calorimetry, Dual-Energy X-Ray Densitometry (DXA, and three-day food diary, respectively. On-water rowing performance and pacing strategy was evaluated from 5 km time trials. Wellness was assessed weekly using the Multicomponent Training Distress Scale (MTDS.Significant decreases in absolute (mean ± SD of difference, p-value: -466 ± 488 kJ.day-1, p = 0.01 and relative RMR (-8.0 ± 8.1 kJ.kg.FFM-1, p = 0.01 were observed. Significant reductions in body mass (-1.6 ± 1.3 kg, p = 0.003 and fat mass (-2.2 ± 1.2 kg, p = 0.0001 were detected, while energy intake was unchanged. On-water 5 km rowing performance worsened (p < 0.05 and an altered pacing strategy was evident. Fatigue and total mood disturbance significantly increased across the cycle (p < 0.05, and trends were observed for reduced vigour and increased sleep disturbance (p < 0.1.Four weeks of heavy training decreased RMR and body composition variables in elite rowers and induced substantial fatigue, likely related to an imbalance between energy intake and output. This study demonstrates that highly experienced athletes do not necessarily select the correct energy intake during periods of intensified training, and this can be assessed by reductions in RMR and body composition. The shortfall in energy availability likely affected recovery from training and altered 5 km time trial

  13. EFFECT OF ADAPTIVE PACED CARDIOLOCOMOTOR SYNCHRONIZATION DURING RUNNING: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    Bill Phillips

    2013-09-01

    Full Text Available Cardiolocomotor synchronization (CLS has been well established for individuals engaged in rhythmic activity, such as walking, running, or cycling. When frequency of the activity is at or near the heart rate, entrainment occurs. CLS has been shown in many cases to improve the efficiency of locomotor activity, improving stroke volume, reducing blood pressure variability, and lowering the oxygen uptake (VO2. Instead of a 1:1 frequency ratio of activity to heart rate, an investigation was performed to determine if different harmonic coupling at other simple integer ratios (e.g. 1:2, 2:3, 3:2 could achieve any performance benefits. CLS was ensured by pacing the stride rate according to the measured heartbeat (i.e., adaptive paced CLS, or forced CLS. An algorithm was designed that determined the simplest ratio (lowest denominator that, when multiplied by the heart rate will fall within an individualized, predetermined comfortable pacing range for the user. The algorithm was implemented on an iPhone 4, which generated a 'tick-tock' sound through the iPhone's headphones. A sham-controlled crossover study was performed with 15 volunteers of various fitness levels. Subjects ran a 3 mile (4.83 km simulated training run at their normal pace on two consecutive days (randomized one adaptive pacing, one sham. Adaptive pacing resulted in faster runs run times, with subjects running an average of 26:03 ± 3:23 for adaptive pacing and 26:38 ± 3:31 for sham (F = 5.46, p < 0.05. The increase in heart rate from the start of the race as estimated by an exponential time constant was significantly longer during adaptive pacing, τ = 0.99 ± 0.30, compared to sham, τ = 1.53 ± 0.34 (t = -6.62, p < 0.01. Eighty-seven percent of runners found it easy to adjust their stride length to match the pacing signal with seventy-nine percent reporting that pacing helped their performance. These results suggest that adaptive paced CLS may have a beneficial effect on running

  14. Kinematic hand parameters in front crawl at different paces of swimming.

    Science.gov (United States)

    Samson, Mathias; Monnet, Tony; Bernard, Anthony; Lacouture, Patrick; David, Laurent

    2015-11-05

    The aim of this study was to investigate the evolution of kinematic hand parameters (sweepback angle, angle of attack, velocity, acceleration and orientation of the hand relative to the absolute coordinate system) throughout an aquatic stroke and to study the possible modifications caused by a variation of the swimming pace. Seventeen competitive swimmers swam at long distance, middle distance and sprint paces. Parameters were calculated from the trajectory of seven markers on the hand measured with an optoelectronic system. Results showed that kinematic hand parameters evolve differently depending on the pace. Angle of attack, sweepback angle, acceleration and orientation of the hand do not vary significantly. The velocity of the hand increases when the pace increases, but only during the less propulsive phases (entry and stretch and downsweep to catch). The more the pace increases and the more the absolute durations of the entry and stretch and downsweep to catch phases decrease. Absolute durations of the insweep and upsweep phases remain constant. During these phases, the propulsive hand forces calculated do not vary significantly when the pace increases. The increase of swimming pace is then explained by the swimmer's capacity to maintain propulsive phases rather than increasing the force generation within each cycle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. No Evidence of XMRV or MuLV Sequences in Prostate Cancer, Diffuse Large B-Cell Lymphoma, or the UK Blood Donor Population

    Directory of Open Access Journals (Sweden)

    Mark James Robinson

    2011-01-01

    Full Text Available Xenotropic murine leukaemia virus-related virus (XMRV is a recently described retrovirus which has been claimed to infect humans and cause associated pathology. Initially identified in the US in patients with prostate cancer and subsequently in patients with chronic fatigue syndrome, doubt now exists that XMRV is a human pathogen. We studied the prevalence of genetic sequences of XMRV and related MuLV sequences in human prostate cancer, from B cell lymphoma patients and from UK blood donors. Nucleic acid was extracted from fresh prostate tissue biopsies, formalin-fixed paraffin-embedded (FFPE prostate tissue and FFPE B-cell lymphoma. The presence of XMRV-specific LTR or MuLV generic gag-like sequences was investigated by nested PCR. To control for mouse DNA contamination, a PCR that detected intracisternal A-type particle (IAP sequences was included. In addition, DNA and RNA were extracted from whole blood taken from UK blood donors and screened for XMRV sequences by real-time PCR. XMRV or MuLV-like sequences were not amplified from tissue samples. Occasionally MuLV gag and XMRV-LTR sequences were amplified from Indian prostate cancer samples, but were always detected in conjunction with contaminating murine genomic DNA. We found no evidence of XMRV or MuLV infection in the UK blood donors.

  16. Arrhythmogenic drugs can amplify spatial heterogeneities in the electrical restitution in perfused guinea-pig heart: An evidence from assessments of monophasic action potential durations and JT intervals.

    Directory of Open Access Journals (Sweden)

    Oleg E Osadchii

    Full Text Available Non-uniform shortening of the action potential duration (APD90 in different myocardial regions upon heart rate acceleration can set abnormal repolarization gradients and promote arrhythmia. This study examined whether spatial heterogeneities in APD90 restitution can be amplified by drugs with clinically proved proarrhythmic potential (dofetilide, quinidine, procainamide, and flecainide and, if so, whether these effects can translate to the appropriate changes of the ECG metrics of ventricular repolarization, such as JT intervals. In isolated, perfused guinea-pig heart preparations, monophasic action potentials and volume-conducted ECG were recorded at progressively increased pacing rates. The APD90 measured at distinct ventricular sites, as well as the JTpeak and JTend values were plotted as a function of preceding diastolic interval, and the maximum slopes of the restitution curves were determined at baseline and upon drug administration. Dofetilide, quinidine, and procainamide reverse rate-dependently prolonged APD90 and steepened the restitution curve, with effects being greater at the endocardium than epicardium, and in the right ventricular (RV vs. the left ventricular (LV chamber. The restitution slope was increased to a greater extent for the JTend vs. the JTpeak interval. In contrast, flecainide reduced the APD90 restitution slope at LV epicardium without producing effect at LV endocardium and RV epicardium, and reduced the JTpeak restitution slope without changing the JTend restitution. Nevertheless, with all agents, these effects translated to the amplified epicardial-to-endocardial and the LV-to-RV non-uniformities in APD90 restitution, paralleled by the increased JTend vs. JTpeak difference in the restitution slope. In summary, these findings suggest that arrhythmic drug profiles are partly attributable to the accentuated regional heterogeneities in APD90 restitution, which can be indirectly determined through ECG assessments of the

  17. Arrhythmogenic drugs can amplify spatial heterogeneities in the electrical restitution in perfused guinea-pig heart: An evidence from assessments of monophasic action potential durations and JT intervals.

    Science.gov (United States)

    Osadchii, Oleg E

    2018-01-01

    Non-uniform shortening of the action potential duration (APD90) in different myocardial regions upon heart rate acceleration can set abnormal repolarization gradients and promote arrhythmia. This study examined whether spatial heterogeneities in APD90 restitution can be amplified by drugs with clinically proved proarrhythmic potential (dofetilide, quinidine, procainamide, and flecainide) and, if so, whether these effects can translate to the appropriate changes of the ECG metrics of ventricular repolarization, such as JT intervals. In isolated, perfused guinea-pig heart preparations, monophasic action potentials and volume-conducted ECG were recorded at progressively increased pacing rates. The APD90 measured at distinct ventricular sites, as well as the JTpeak and JTend values were plotted as a function of preceding diastolic interval, and the maximum slopes of the restitution curves were determined at baseline and upon drug administration. Dofetilide, quinidine, and procainamide reverse rate-dependently prolonged APD90 and steepened the restitution curve, with effects being greater at the endocardium than epicardium, and in the right ventricular (RV) vs. the left ventricular (LV) chamber. The restitution slope was increased to a greater extent for the JTend vs. the JTpeak interval. In contrast, flecainide reduced the APD90 restitution slope at LV epicardium without producing effect at LV endocardium and RV epicardium, and reduced the JTpeak restitution slope without changing the JTend restitution. Nevertheless, with all agents, these effects translated to the amplified epicardial-to-endocardial and the LV-to-RV non-uniformities in APD90 restitution, paralleled by the increased JTend vs. JTpeak difference in the restitution slope. In summary, these findings suggest that arrhythmic drug profiles are partly attributable to the accentuated regional heterogeneities in APD90 restitution, which can be indirectly determined through ECG assessments of the JTend vs. JTpeak

  18. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Jensen, Christoph J.; Jochims, Markus; Hunold, Peter; Forsting, Michael; Barkhausen, Joerg; Sabin, Georg V.; Bruder, Oliver; Schlosser, Thomas

    2010-01-01

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 ± 8% vs. 64 ± 8%, p = 0.47; EDV 136 ± 36 ml vs. 138 ± 35 ml, p = 0.66; ESV 52 ± 21 ml vs. 52 ± 22 ml, p = 0.61; SV 83 ± 22 ml vs. 87 ± 19 ml, p = 0.22; CO 5.4 ± 0.9 l/min vs. 5.7 ± 1.2 l/min, p = 0.09, LVM 132 ± 33 g vs. 132 ± 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 ± 8% vs. 62 ± 9%; SV 73 ± 17 ml vs. 81 ± 15 ml; CO 5.7 ± 1.2 l/min vs. 5.0 ± 0.8 l/min; ESV 52 ± 27 ml vs. 57 ± 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 ± 31 g vs. 132 ± 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  19. Pacing and Self-regulation: Important Skills for Talent Development in Endurance Sports.

    Science.gov (United States)

    Elferink-Gemser, Marije T; Hettinga, Florentina J

    2017-07-01

    Pacing has been characterized as a multifaceted goal-directed process of decision making in which athletes need to decide how and when to invest their energy during the race, a process essential for optimal performance. Both physiological and psychological characteristics associated with adequate pacing and performance are known to develop with age. Consequently, the multifaceted skill of pacing might be under construction throughout adolescence, as well. Therefore, the authors propose that the complex skill of pacing is a potential important performance characteristic for talented youth athletes that needs to be developed throughout adolescence. To explore whether pacing is a marker for talent and how talented athletes develop this skill in middle-distance and endurance sports, they aim to bring together literature on pacing and literature on talent development and self-regulation of learning. Subsequently, by applying the cyclical process of self-regulation to pacing, they propose a practical model for the development of performance in endurance sports in youth athletes. Not only is self-regulation essential throughout the process of reaching the long-term goal of athletic excellence, but it also seems crucial for the development of pacing skills within a race and the development of a refined performance template based on previous experiences. Coaches and trainers are advised to incorporate pacing as a performance characteristic in their talent-development programs by stimulating their athletes to reflect, plan, monitor, and evaluate their races on a regular basis to build performance templates and, as such, improve their performance.

  20. Differential effects of film on preschool children's behaviour dependent on editing pace.

    Science.gov (United States)

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  1. Frequency-dependent left ventricular performance in women and men.

    Science.gov (United States)

    Wainstein, Rodrigo V; Sasson, Zion; Mak, Susanna

    2012-06-01

    We aimed to determine whether sex differences in humans extend to the dynamic response of the left ventricular (LV) chamber to changes in heart rate (HR). Several observations suggest sex influences LV structure and function in health; moreover, this physiology is also affected in a sex-specific manner by aging. Eight postmenopausal women and eight similarly aged men underwent a cardiac catheterization-based study for force-interval relationships of the LV. HR was controlled by right atrial (RA) pacing, and LV +dP/dt(max) and volume were assessed by micromanometer-tipped catheter and Doppler echocardiography, respectively. Analysis of approximated LV pressure-volume relationships was performed using a time-varying model of elastance. External stroke work was also calculated. The relationship between HR and LV +dP/dt(max) was expressed as LV +dP/dt(max) = b + mHR. The slope (m) of the relationship was steeper in women compared with men (11.8 ± 4.0 vs. 6.1 ± 4.1 mmHg·s(-1)·beats(-1)·min(-1), P = 0.01). The greater increase in contractility in women was reproducibly observed after normalizing LV +dP/dt(max) to LV end-diastolic volume (LVVed) or by measuring end-systolic elastance. LVVed and stroke volume decreased more in women. Thus, despite greater increases in contractility, HR was associated with a lesser rise in cardiac output and a steeper fall in external stroke work in women. Compared with men, women exhibit greater inotropic responses to incremental RA pacing, which occurs at the same time as a steeper decline in external stroke work. In older adults, we observed sexual dimorphism in determinants of LV mechanical performance.

  2. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  3. Left ventricular epicardial activation increases transmural dispersion of repolarization in healthy, long QT, and dilated cardiomyopathy dogs.

    Science.gov (United States)

    Bai, Rong; Lü, Jiagao; Pu, Jun; Liu, Nian; Zhou, Qiang; Ruan, Yanfei; Niu, Huiyan; Zhang, Cuntai; Wang, Lin; Kam, Ruth

    2005-10-01

    Benefits of cardiac resynchronization therapy (CRT) are well established. However, less is understood concerning its effects on myocardial repolarization and the potential proarrhythmic risk. Healthy dogs (n = 8) were compared to a long QT interval (LQT) model (n = 8, induced by cesium chloride, CsCl) and a dilated cardiomyopathy with congestive heart failure (DCM-CHF, induced by rapid ventricular pacing, n = 5). Monophasic action potential (MAP) recordings were obtained from the subendocardium, midmyocardium, subepicardium, and the transmural dispersion of repolarization (TDR) was calculated. The QT interval and the interval from the peak to the end of the T wave (T(p-e)) were measured. All these characteristics were compared during left ventricular epicardial (LV-Epi), right ventricular endocardial (RV-Endo), and biventricular (Bi-V) pacing. In healthy dogs, TDR prolonged to 37.54 ms for Bi-V pacing and to 47.16 ms for LV-Epi pacing as compared to 26.75 ms for RV-Endo pacing (P canine models in addition to their intrinsic transmural heterogeneity in the intact heart. This mechanism may contribute to the development of malignant ventricular arrhythmias, such as torsades de pointes (TdP) in congestive heart failure (CHF) patients treated with CRT.

  4. To pace or not to pace: a pilot study of four- and five-gaited Icelandic horses homozygous for the DMRT3 'Gait Keeper' mutation.

    Science.gov (United States)

    Jäderkvist Fegraeus, K; Hirschberg, I; Árnason, T; Andersson, L; Velie, B D; Andersson, L S; Lindgren, G

    2017-12-01

    The Icelandic horse is a breed known mainly for its ability to perform the ambling four-beat gait 'tölt' and the lateral two-beat gait pace. The natural ability of the breed to perform these alternative gaits is highly desired by breeders. Therefore, the discovery that a nonsense mutation (C>A) in the DMRT3 gene was the main genetic factor for horses' ability to perform gaits in addition to walk, trot and canter was of great interest. Although several studies have demonstrated that homozygosity for the DMRT3 mutation is important for the ability to pace, only about 70% of the homozygous mutant (AA) Icelandic horses are reported to pace. The aim of the study was to genetically compare four- and five-gaited (i.e. horses with and without the ability to pace) AA Icelandic horses by performing a genome-wide association (GWA) analysis. All horses (n = 55) were genotyped on the 670K Axiom Equine Genotyping Array, and a GWA analysis was performed using the genabel package in r. No SNP demonstrated genome-wide significance, implying that the ability to pace goes beyond the presence of a single gene variant. Despite its limitations, the current study provides additional information regarding the genetic complexity of pacing ability in horses. However, to fully understand the genetic differences between four- and five-gaited AA horses, additional studies with larger sample materials and consistent phenotyping are needed. © 2017 Stichting International Foundation for Animal Genetics.

  5. The B → D*lv form factor at zero recoil

    International Nuclear Information System (INIS)

    Simone, J.N.; Hashimoto, S.; El-Khadra, A.X.; Kronfeld, A.S.; Mackenzie, P.B.; Ryan, S.M.

    2000-01-01

    We describe a model independent lattice QCD method for determining the deviation from unity for h A1 (1), the B → D*lv form factor at zero recoil. We extend the double ratio method previously used to determine the B → Dlv form factor. The bulk of statistical and systematic errors cancel in the double ratios we consider, yielding form factors which promise to reduce present theoretical uncertainties in the determination of parallel V cb parallel. We present results from a prototype calculation at a single lattice spacing corresponding to β = 5.7

  6. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    Science.gov (United States)

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  7. PACE-90 water and solute transport calculations for 0.01, 0.1, and 0. 5 mm/yr infiltration into Yucca Mountain

    International Nuclear Information System (INIS)

    Dykhuizen, R.C.; Eaton, R.R.; Hopkins, P.L.; Martinez, M.J.

    1991-12-01

    Numerical results are presented for the Performance Assessment Calculational Exercise (PACE-90). One- and two-dimensional water and solute transport are presented for steady infiltration into Yucca Mountain. Evenly distributed infiltration rates of 0.01, 0.1, and 0.5 mm/yr were considered. The calculations of solute transport show that significant amounts of radionuclides can reach the water table over 100,000 yr at the 0.5 mm/yr rate. For time periods less than 10,000 yr or infiltrations less than 0.1 mm/yr very little solute reaches the water table. The numerical simulations clearly demonstrate that multi-dimensional effects can result in significant decreases in the travel time of solute through the modeled domain. Dual continuum effects are shown to be negligible for the low steady state fluxes considered. However, material heterogeneities may cause local amplification of the flux level in multi-dimensional flows. These higher flux levels may then require modeling of a dual continuum porous medium

  8. The solarPACES strategy for the solar thermal breakthrough

    International Nuclear Information System (INIS)

    Burch, G.D.; Grasse, W.

    1997-01-01

    IEA(International Energy Agency)/SolarPACES(Solar Power and Chemical Energy systems)represents a world wide coalition for information sharing and collaboration on applications of concentrated solar energy. The current SolarPACES community has built up solar thermal system know-how over 15 years, is operating the three main solar test centres in the world. Its main activities are in the following four fields: solar thermal electric power systems, solar chemistry, solar technology and advanced applications and non-technical activities. The article presents the talk on the strategy of solarPACES given at the International Workshop on applied solar energy held in Tashkent(Uzbekistan) in June 1997. (A.A.D.)

  9. METODE FUTURE PACING HYPNOTHERAPY UNTUK MENURUNKAN TINGKAT KECEMASAN PADA MAHASISWA BARU

    Directory of Open Access Journals (Sweden)

    Zahro Varisna Rohmadani

    2017-09-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui efektivitas metode future pacing hypnotherapy dalam menurunkan tingkat kecemasan pada mahasiswa baru. Subjek penelitian adalah 20 mahasiswa/i baru, 10 mahasiswa di kelompok eksperimen dan 10 mahasiswa di kelompok kontrol. Peserta mendapatkan penanganan untuk penurunan kecemasan dengan metode berupa future pacing hypnotherapy. Metode analisis data yang digunakan adalah statistik nonparametrik teknik Wilcoxon Signed Rank Test untuk menguji perbedaan skor cemas kelompok subjek saat pretest dan posttest serta Mann Whitney U untuk melihat perbedaan penurunan kecemasan pada kelompok eksperimen dan kelompok kontrol. Hasil Wilcoxon Signed Rank Test menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,012. Sedangkan hasil Mann Whitney U menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,003 dan kelompok eksperimen mengalami penurunan kecemasan yang lebih besar dengan mean rank = 14,25.Kata kunci : future pacing hypnotherapy, kecemasan, mahasiswa baru

  10. Off-site environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1985

    International Nuclear Information System (INIS)

    Grossman, R.F.; Black, S.C.; Dye, R.E.; Smith, D.D.; Thome, D.J.; Mullen, A.A.

    1986-04-01

    The EMSL-LV operates an Off-Site Radiological Safety Program around the NTS and other sites as requested by the Department of Energy (DOE) under an Interagency Agreement between DOE and EPA. This report, prepared in accordance with DOE guidelines (DOE85a), covers the program activities for calendar year 1985. It contains descriptions of pertinent features of the NTS and its environs, summaries of the EMSL-LV dosimetry and sampling methods, analytical procedures, quality assurance, and the analytical results from environmental measurements. Where applicable, dosimetry and sampling data are compared to appropriate guides for external and internal exposures of humans to ionizing radiation

  11. Agent-based unified approach for thermal and voltage constraint management in LV distribution network

    NARCIS (Netherlands)

    Haque, A.N.M.M.; Nguyen, H.P.; Vo, T.; Bliek, F.W.

    2016-01-01

    Rapid proliferation of the distributed energy resources (DERs) poses operational challenges for the low-voltage (LV) distribution networks in terms of thermal overloading of the network assets along with voltage limit violations at the connection points. A number of market-based and direct control

  12. Assessment of global left ventricular function with dual-source computed tomography in patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Bak, So Hyeon; Jeon, Hae Jeong (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Ko, Sung Min (Dept. of Radiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of); Research Inst. of Medical Science, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)), Email: 20070437@kuh.ac.kr; Yang, Hyun Suk; Hwang, Hweung Kon (Dept. of Cardiology, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of)); Song, Meong Gun (Dept. of Thoracic Surgery, Konkuk Univ. Hospital, Konkuk Univ. School of Medicine, Seoul (Korea, Republic of))

    2012-04-15

    Background: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. Purpose: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). Material and Methods: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. Results: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV

  13. Assessment of global and regional LV function obtained by quantitative gated SPECT using {sup 99m}Tc-tetrofosmin. Comparison with left ventricular cineangiography and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Kazunobu; Nakajima, Toru; Aoki, Naoto; Abe, Sumihisa; Handa, Shunnosuke; Suzuki, Yutaka [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    1998-11-01

    The quantitative gated SPECT (QGS) software that has automatic edge detection algorithm of the left ventricle, is able to calculate LV volumes and visualize LV wall motion with perfusion throughout the cardiac cycle. We evaluated the reliability of global and regional LV function derived from QGS using {sup 99m}Tc-tetrofosmin by comparing with left ventricular cineangiography (LVG) and echocardiography (ECHO). In 22 cardiac patients, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. Using cinematic display, regional LV wall motion were scored on a 3-point scale (1=normal, 2=hypokinesis, 3=akinesis; WMS). EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). Correlation between WMS derived from QGS and ECHO was high (r=0.85, p<0.001). There was an inverse correlation between WMS and LVEF (r=0.77, p<0.001). In conclusion, QGS is useful to evaluate global LV function. Regional wall motion evaluated by QGS is good enough for clinical application. (author)

  14. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca2+-sensitive K+ current in miniature swine with LV hypertrophy

    Science.gov (United States)

    Tharp, Darla L.; Ivey, Jan R.; Ganjam, Venkataseshu K.; Bowles, Douglas K.

    2011-01-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ETA) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K+ currents (IK+) in coronary smooth muscle cells. Raising internal Ca2+ from 200 to 500 nM increased Ca2+-sensitive K+ current in HF-TR and control, but not HF animals. In conclusion, an ETA-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca2+-sensitive IK+ was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca2+-sensitive IK+, illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy. PMID:21841018

  15. Soil and groundwater remediation using dual-phase extraction technology

    International Nuclear Information System (INIS)

    Miller, A.W.; Gan, D.R.

    1995-01-01

    A gasoline underground storage tank (UST) was formerly used to fuel vehicles for a hospital in Madison, Wisconsin. Elevated concentrations of gasoline range organics (GRO) were observed in soils and groundwater at the site during the tank removal and a subsequent site investigation. Based on the extent of soil and groundwater contamination, a dual-phase extraction technology was selected as the most cost effective alternative to remediate the site. The dual-phase extraction system includes one extraction well functioning both as a soil vapor extraction (SVE) and groundwater recovery well. After six months of operation, samples collected from the groundwater monitoring wells indicated that the groundwater has been cleaned up to levels below the Wisconsin preventative action limits. The dual-phase extraction system effectively remediated the site in a short period of time, saving both operation and maintenance costs and overall project cost

  16. Self-Paced Instruction: Hello, Education

    Science.gov (United States)

    Leuba, Richard J.; Flammer, Gordon H.

    1975-01-01

    Answers criticisms of self-paced instruction (SPI) by citing advantages of SPI over lecture methods. Concludes that criticisms of SPI are useful since they indicate in which areas further research should be conducted to improve this method of instruction. (MLH)

  17. Pace: an advanced structure for handling multi-technique NDT

    International Nuclear Information System (INIS)

    Mayos, M.; Guisnel, F.

    1995-08-01

    The growing extent and complexity of NDT data analysis has reached a stage where dedicated systems are required. In the context of a European research program, EDF participated from 1992 to 1994 in one of the first international projects in this field, TRAPPIST and, in 1993, began developing An application for the electricity generating industry, giving rise to the PACE project. The prime objective specially targets the French electricity generating industry, where PACE was to be the reference system for analysis of NDE data concerning EdF power plants. The second objective is to promote the adoption of PACE by other industrial sectors and other countries. The analysis of needs shows that the required system must be designed to analyze data from widely different sources. The PACE entry point consequently has to be a standard format compatible with geometrical data as well as those provided by NDT. The TRAPPIST format constitutes the first version of this standard and is the first step towards European standardization in this respect. Consideration of the different user modes defined for PACE led to the design of a 2-part user structure comprising a database management system (Ingres/Windows 4GL) and a display/processing tool (AVS), also usable to construct analysis scenarios. The structure of PACE is defined nd seems well suited to industrial requirements, but before it is possible to proceed further towards its adoption for actual power plant inspections, it has to be validated on a more realistic application, the eddy current and ultrasonic testing of a full-scale T-joint. This is already under way, whilst work on format standardization and industrialization preparatory procedures are proceeding in parallel. (authors). 4 refs., 6 figs

  18. Astakine LvAST binds to the β subunit of F1-ATP synthase and likely plays a role in white shrimp Litopeneaus vannamei defense against white spot syndrome virus.

    Science.gov (United States)

    Liang, Gao-Feng; Liang, Yan; Xue, Qinggang; Lu, Jin-Feng; Cheng, Jun-Jun; Huang, Jie

    2015-03-01

    Cytokines play a critical role in innate and adaptive immunity. Astakines represent a group of invertebrate cytokines that are related to vertebrate prokineticin and function in promoting hematopoiesis in crustaceans. We have identified an astakine from the white shrimp Litopeneaus vannamei and named it LvAST in a previous research. In the present research, we investigated the interactions among LvAST, the envelope protein VP37 of white spot syndrome virus (i.e., WSSV), and the β subunit of F1-ATP synthase (ATPsyn-β) of the white shrimp (i.e., BP53) using binding assays and co-precipitations. We also examined the effects of LvAST on shrimp susceptibility to WSSV. We found that LvAST and VP37 competitively bound to BP53, but did not bind to each other. Shrimps that had been injected with recombinant LvAST exhibited significantly lower mortality and longer survival time in experimental infections by WSSV. In contrast, shrimps whose LvAST gene expression had been inhibited by RNA interference showed significantly higher WSSV infection intensity and shorter survival time following viral challenges. These results suggested that LvAST and WSSV both likely use ATPsyn-β as a receptor and LvAST plays a role in shrimp defense against WSSV infection. This represented the first research showing the involvement of astakines in host antiviral immunity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Pacing in swimming - variability and effects of manipulations

    OpenAIRE

    Skorski, Sabrina

    2015-01-01

    Introduction: In any athletic event, the ability to appropriately distribute energy, is essential to prevent premature fatigue prior to the completion of the event. In sport science literature this is termed ‘pacing’. Within the past decade, research aiming to better understand the underlying mechanisms influencing the selection of an athlete’s pacing during exercise has dramatically increased. It is suggested that pacing is a combination of anticipation, knowledge of the end-point, prior exp...

  20. Site-selective dopant profiling of p-n junction specimens in the dual-beam FIB/SEM system

    International Nuclear Information System (INIS)

    Chee, K W A; Beanland, R; Midgley, P A; Humphreys, C J

    2010-01-01

    Results from site-specific dopant profiling in a dual-beam FIB/SEM system are reported. Si specimens containing p-n junctions were milled using Ga + ion beam energies ranging from 30 keV to 2 keV, and analysed in situin the vacuum chamber. We compare the dopant contrast observed when milling a cleaved surface to that obtained from a side-wall of a trench cut using 30 kV Ga + ions, and using successively lower ion beam energies. The latter technique is suitable for site-specific dopant profiling. We find that lower energy ion beam milling significantly improves contrast, but only achieves 50 % of that observed on a freshly-cleaved surface. Furthermore, the contrast on a side-wall previously milled using high energy Ga + ions is less than that of a cleaved surface subjected to the same ion beam energy.

  1. Supporting documents for LLL area 27 (410 area) safety analysis reports, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Odell, B. N. [comp.

    1977-02-01

    The following appendices are common to the LLL Safety Analysis Reports Nevada Test Site and are included here as supporting documents to those reports: Environmental Monitoring Report for the Nevada Test Site and Other Test Areas Used for Underground Nuclear Detonations, U. S. Environmental Protection Agency, Las Vegas, Rept. EMSL-LV-539-4 (1976); Selected Census Information Around the Nevada Test Site, U. S. Environmental Protection Agency, Las Vegas, Rept. NERC-LV-539-8 (1973); W. J. Hannon and H. L. McKague, An Examination of the Geology and Seismology Associated with Area 410 at the Nevada Test Site, Lawrence Livermore Laboratory, Livermore, Rept. UCRL-51830 (1975); K. R. Peterson, Diffusion Climatology for Hypothetical Accidents in Area 410 of the Nevada Test Site, Lawrence Livermore Laboratory, Livermore, Rept. UCRL-52074 (1976); J. R. McDonald, J. E. Minor, and K. C. Mehta, Development of a Design Basis Tornado and Structural Design Criteria for the Nevada Test Site, Nevada, Lawrence Livermore Laboratory, Livermore, Rept. UCRL-13668 (1975); A. E. Stevenson, Impact Tests of Wind-Borne Wooden Missiles, Sandia Laboratories, Tonopah, Rept. SAND 76-0407 (1976); and Hydrology of the 410 Area (Area 27) at the Nevada Test Site.

  2. Dual-mode fluorophore-doped nickel nitrilotriacetic acid-modified silica nanoparticles combine histidine-tagged protein purification with site-specific fluorophore labeling.

    Science.gov (United States)

    Kim, Sung Hoon; Jeyakumar, M; Katzenellenbogen, John A

    2007-10-31

    We present the first example of a fluorophore-doped nickel chelate surface-modified silica nanoparticle that functions in a dual mode, combining histidine-tagged protein purification with site-specific fluorophore labeling. Tetramethylrhodamine (TMR)-doped silica nanoparticles, estimated to contain 700-900 TMRs per ca. 23 nm particle, were surface modified with nitrilotriacetic acid (NTA), producing TMR-SiO2-NTA-Ni2+. Silica-embedded TMR retains very high quantum yield, is resistant to quenching by buffer components, and is modestly quenched and only to a certain depth (ca. 2 nm) by surface-attached Ni2+. When exposed to a bacterial lysate containing estrogen receptor alpha ligand binding domain (ERalpha) as a minor component, these beads showed very high specificity binding, enabling protein purification in one step. The capacity and specificity of these beads for binding a his-tagged protein were characterized by electrophoresis, radiometric counting, and MALDI-TOF MS. ERalpha, bound to TMR-SiO2-NTA-Ni++ beads in a site-specific manner, exhibited good activity for ligand binding and for ligand-induced binding to coactivators in solution FRET experiments and protein microarray fluorometric and FRET assays. This dual-mode type TMR-SiO2-NTA-Ni2+ system represents a powerful combination of one-step histidine-tagged protein purification and site-specific labeling with multiple fluorophore species.

  3. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker.

    Science.gov (United States)

    Ritter, Philippe; Duray, Gabor Z; Zhang, Shu; Narasimhan, Calambur; Soejima, Kyoko; Omar, Razali; Laager, Verla; Stromberg, Kurt; Williams, Eric; Reynolds, Dwight

    2015-05-01

    Recent advances in miniaturization technologies and battery chemistries have made it possible to develop a pacemaker small enough to implant within the heart while still aiming to provide similar battery longevity to conventional pacemakers. The Micra Transcatheter Pacing System is a miniaturized single-chamber pacemaker system that is delivered via catheter through the femoral vein. The pacemaker is implanted directly inside the right ventricle of the heart, eliminating the need for a device pocket and insertion of a pacing lead, thereby potentially avoiding some of the complications associated with traditional pacing systems. The Micra Transcatheter Pacing Study is currently undergoing evaluation in a prospective, multi-site, single-arm study. Approximately 720 patients will be implanted at up to 70 centres around the world. The study is designed to have a continuously growing body of evidence and data analyses are planned at various time points. The primary safety and efficacy objectives at 6-month post-implant are to demonstrate that (i) the percentage of Micra patients free from major complications related to the Micra system or implant procedure is significantly higher than 83% and (ii) the percentage of Micra patients with both low and stable thresholds is significantly higher than 80%. The safety performance benchmark is based on a reference dataset of 977 subjects from 6 recent pacemaker studies. The Micra Transcatheter Pacing Study will assess the safety and efficacy of a miniaturized, totally endocardial pacemaker in patients with an indication for implantation of a single-chamber ventricular pacemaker. NCT02004873. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. PACE3 - front-end chip for the CMS Preshower

    CERN Multimedia

    Aspel, Paul

    2003-01-01

    This is PACE3 which is the front-end chip for the CMS Preshower. In fact PACE3 is the combination of two ASICs called Delta3 and PACEAM3. Delta3 is on the left and PACEAM3 is on the right. The two ASICs are bonded together and then packaged within a single 196 pin fpBGA package.

  5. A human factors experiment on the event-paced control tasks issue

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Chul; Park, Jae Chang; Oh, In Seok; Lee, Jung Woon; Lee, Ki Young; Park, Jong Kyun [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-03-01

    KEPRI(Korea Electric Power Research Institute) requires human factors validation tests according to the progress of the KNGR MMI design. This report describes the experimental results of an human factors validation issue, Event-Paced Control Tasks issue. The Event-Paced Control Task issue is to test that the designed MMI shall support operators in performing control tasks in pace with the plant dynamics. Task completion time and successful execution are defined as performance measures on the issue. Through an experiment on the issue with 3 scenarios and 5 subjects, we report that the variation of task completion time between subjects has a narrow band for each scenarios, however two among the total 15 experimental runs result in the failure that subject does not reach to the predefined operational goal. Incorrect operational strategy, insufficient training, and MMI design discrepancies are inferred as the causes of the failures. However these experimental results don't indicate the close of the Event-Paced Control Tasks issue. The validation test results under the experimental environment composed of the partial MMI representations, an unstable simulator, and insufficient subject training, are significant in the limited conditions. Thus, for the purpose of the complete issue close, the validation test on the Event-Paced Control Tasks issue should be repeatedly carried out in pace with the performance improvement of the experimental environment. 13 figs., 4 tabs. (Author)

  6. Partial LVAD restores ventricular outputs and normalizes LV but not RV stress distributions in the acutely failing heart in silico

    OpenAIRE

    Sack, Kevin L.; Baillargeon, Brian; Acevedo-Bolton, Gabriel; Genet, Martin; Rebelo, Nuno; Kuhl, Ellen; Klein, Liviu; Weiselthaler, Georg M.; Burkhoff, Daniel; Franz, Thomas; Guccione, Julius M.

    2016-01-01

    Purpose: Heart failure is a worldwide epidemic that is unlikely to change as the population ages and life expectancy increases. We sought to detail significant recent improvements to the Dassault Systèmes Living Heart Model (LHM) and use the LHM to compute left ventricular (LV) and right ventricular (RV) myofiber stress distributions under the following 4 conditions: (1) normal cardiac function; (2) acute left heart failure (ALHF); (3) ALHF treated using an LV assist device (LVAD) flow rate o...

  7. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  8. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  9. First reported experience with intramuscular diaphragm pacing in replacing positive pressure mechanical ventilators in children.

    Science.gov (United States)

    Onders, Raymond P; Ponsky, Todd A; Elmo, MaryJo; Lidsky, Karen; Barksdale, Edward

    2011-01-01

    Diaphragm pacing (DP) has been shown to successfully replace mechanical ventilators for adult tetraplegic patients with chronic respiratory insufficiency. This is the first report of DP in ventilator-dependent children. This was a prospective interventional experience under institutional review board approval. Diaphragm pacing involves outpatient laparoscopic diaphragm motor point mapping to identify the site where stimulation causes maximum diaphragm contraction with implantation of 4 percutaneous intramuscular electrodes. Diaphragm conditioning ensues to wean the child from the ventilator. Six children were successfully implanted ranging from 5 to 17 years old with the smallest 15 kg in weight. Length of time on mechanical ventilation ranged from 11 days to 7.6 years with an average of 3.2 years. In all patients, DP provided tidal volumes above basal needs. Five of the patients underwent a home-based weaning program, whereas one patient who was implanted only 11 days post spinal cord injury never returned to the ventilator with DP use. Another patient was weaned from the ventilator full time but died of complications of his underlying brain stem tumor. The remaining patients weaned from the ventilator for over 14 hours a day and/or are actively conditioning their diaphragms. Diaphragm pacing successfully replaced mechanical ventilators, which improves quality of life. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Rhythm perturbations in acoustically paced treadmill walking after stroke.

    Science.gov (United States)

    Roerdink, Melvyn; Lamoth, Claudine J C; van Kordelaar, Joost; Elich, Peter; Konijnenbelt, Manin; Kwakkel, Gert; Beek, Peter J

    2009-09-01

    In rehabilitation, acoustic rhythms are often used to improve gait after stroke. Acoustic cueing may enhance gait coordination by creating a stable coupling between heel strikes and metronome beats and provide a means to train the adaptability of gait coordination to environmental changes, as required in everyday life ambulation. To examine the stability and adaptability of auditory-motor synchronization in acoustically paced treadmill walking in stroke patients. Eleven stroke patients and 10 healthy controls walked on a treadmill at preferred speed and cadence under no metronome, single-metronome (pacing only paretic or nonparetic steps), and double-metronome (pacing both footfalls) conditions. The stability of auditory-motor synchronization was quantified by the variability of the phase relation between footfalls and beats. In a separate session, the acoustic rhythms were perturbed and adaptations to restore auditory-motor synchronization were quantified. For both groups, auditory-motor synchronization was more stable for double-metronome than single-metronome conditions, with stroke patients exhibiting an overall weaker coupling of footfalls to metronome beats than controls. The recovery characteristics following rhythm perturbations corroborated the stability findings and further revealed that stroke patients had difficulty in accelerating their steps and instead preferred a slower-step response to restore synchronization. In gait rehabilitation practice, the use of acoustic rhythms may be more effective when both footfalls are paced. In addition, rhythm perturbations during acoustically paced treadmill walking may not only be employed to evaluate the stability of auditory-motor synchronization but also have promising implications for evaluation and training of gait adaptations in neurorehabilitation practice.

  11. Factors affecting the regulation of pacing: current perspectives

    Directory of Open Access Journals (Sweden)

    Mauger AR

    2014-09-01

    Full Text Available Alexis R Mauger Endurance Research Group, School of Sport and Exercise Sciences, Faculty of Science, University of Kent, Chatham, UK Abstract: During prolonged dynamic and rhythmic exercise, muscular pain and discomfort arises as a result of an increased concentration of deleterious metabolites. Sensed by peripheral nociceptors and transmitted via afferent feedback to the brain, this provides important information regarding the physiological state of the muscle. These sensations ultimately contribute to what is termed "exercise-induced pain". Despite being well recognized by athletes and coaches, and suggested to be integral to exercise performance, this construct has largely escaped attention in experimental work. This perspective article highlights the current understanding of pacing in endurance performance, and the causes of exercise-induced pain. A new perspective is described, which proposes how exercise-induced pain may be a contributing factor in helping individuals to regulate their work rate during exercise and thus provides an important construct in pacing. Keywords: pain, exercise-induced pain, discomfort, exercise performance, self-paced

  12. Optimal pacing strategy: From theoretical modeling to reality in 1500m speed skating

    NARCIS (Netherlands)

    Hettinga, F.J.; de Koning, J.J.; Schmidt, L.J.I.; Wind, N.A.C.; McIntosh, B.; Foster, C.

    2011-01-01

    Purpose: Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  13. Optimal pacing strategy : from theoretical modelling to reality in 1500-m speed skating

    NARCIS (Netherlands)

    Hettinga, F. J.; De Koning, J. J.; Schmidt, L. J. I.; Wind, N. A. C.; MacIntosh, B. R.; Foster, C.

    Purpose Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  14. Leadless Pacing: Current State and Future Direction.

    Science.gov (United States)

    Merkel, Matthias; Grotherr, Philipp; Radzewitz, Andrea; Schmitt, Claus

    2017-12-01

    Leadless pacing is now an established alternative to conventional pacing with subcutaneous pocket and transvenous lead for patients with class I or II single-chamber pacing indication. Available 12-month follow-up data shows a 48% fewer major complication rate in patients with Micra™ compared to a historical control group in a nonrandomized study [1]. There is one system with Food and Drug Administration (FDA) approval and two with the Communauté Européenne (CE) mark. The OPS code for the implantation is 8-83d.3 and the procedure has recently been rated as a "new Examination and Treatment Method (NUB)" in the German DRG system, meaning adequate reimbursement is negotiable with health insurance providers. The systems offer similar generator longevity and programming possibilities as conventional pacemaker systems, including rate response, remote monitoring, and MRI safety. The biggest downsides to date are limitations to single-chamber stimulation, lack of long-time data, and concerns of handling of the system at the end of its life span. However, implant procedure complication rates and procedure times do not exceed conventional pacemaker operations, and proper training and patient selection is provided.

  15. Cardiac optogenetic pacing in drosophila melanogaster using red-shifted opsins (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Electrical pacing is the current gold standard for investigation of mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, this method requires an invasive surgical procedure to implant the pacing electrodes. Recently, optogenetic pacing has been developed as an alternative, non-invasive method for heartbeat pacing in animals. It induces heartbeats by shining pulsed light on transgene-generated microbial opsins which in turn activate light gated ion channels in animal hearts. However, commonly used opsins, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we expressed recently engineered red-shifted opsins, ReaChR and CsChrimson, in the heart of a well-developed animal model, Drosophila melanogaster, for the first time. Optogenetic pacing was successfully conducted in both ReaChR and CsChrimson flies at their larval, pupal, and adult stages using 617 nm excitation light pulse, enabling a much deeper tissue penetration compared to blue stimulation light. A customized high speed and ultrahigh resolution OCM system was used to non-invasively monitor the heartbeat pacing in Drosophila. Compared to previous studies on optogenetic pacing of Drosophila, higher penetration depth of optogenetic excitation light was achieved in opaque late pupal flies. Lower stimulating power density is needed for excitation at each developmental stage of both groups, which improves the safety of this technique for heart rhythm studies.

  16. Predicting Successful Completion Using Student Delay Indicators in Undergraduate Self-Paced Online Courses

    Science.gov (United States)

    Lim, Janine M.

    2016-01-01

    Self-paced online courses meet flexibility and learning needs of many students, but skepticism persists regarding the quality and the tendency for students to procrastinate in self-paced courses. Research is needed to understand procrastination and delay patterns of students in online self-paced courses to predict successful completion and…

  17. Estimation of Maximum Allowable PV Connection to LV Residential Power Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    Maximum photovoltaic (PV) hosting capacity of low voltage (LV) power networks is mainly restricted by either thermal limits of network components or grid voltage quality resulted from high penetration of distributed PV systems. This maximum hosting capacity may be lower than the available solar...... potential of geographic area due to power network limitations even though all rooftops are fully occupied with PV modules. Therefore, it becomes more of an issue to know what exactly limits higher PV penetration level and which solutions should be engaged efficiently such as over sizing distribution...

  18. Voltage regulation in LV grids by coordinated volt-var control strategies

    DEFF Research Database (Denmark)

    Juamperez Goñi, Miguel Angel; Yang, Guangya; Kjær, Søren Bækhøj

    2014-01-01

    in a representative LV network in Bornholm Island using a multi-objective genetic algorithm. The approach is to increase the reactive power contribution of the inverters closest to the transformer during overvoltage conditions. Two standard reactive power control concepts, cosΦ(P) and Q(U), are simulated and compared...... in terms of network power losses and voltage level along the feeder. As a practical implementation, a reconfigurable hardware is used for developing a testing platform based on real-time measurements to regulate the reactive power level. The proposed testing platform has been developed within PVNET...

  19. Population distribution around the Nevada Test Site, 1984

    International Nuclear Information System (INIS)

    Smith, D.D.; Coogan, J.S.

    1984-08-01

    The Environmental Monitoring Systems Laboratory (EMSL-LV) conducts an offsite radiological safety program outside the boundaries of the Nevada Test Site. As part of this program, the EMSL-LV maintains a comprehensive and current listing of all rural offsite residents and dairy animals within the controllable sectors (areas where the EMSL-LV could implement protective or remedial actions that would assure public safety). This report was produced to give a brief overview of the population distribution and information on the activities within the controllable sectors. Obviously the numbers of people in a sector change dependent upon the season of the year, and such diverse information as the price of minerals which relates to the opening and closing of mining operations. Currently, the controllable sectors out to 200 kilometers from the Control Point on the NTS are considered to be the entire northeast, north-northeast, north, north-northwest, west-northwest sectors and portions of the east and east-northeast sectors. The west-southwest and south-southwest sections are considered controllable out to 40 to 80 kilometers. No major population centers or dairy farms lie within these sectors. 7 references, 5 figures, 2 tables

  20. The Efficacy of Self-Paced Study in Multitrial Learning

    Science.gov (United States)

    de Jonge, Mario; Tabbers, Huib K.; Pecher, Diane; Jang, Yoonhee; Zeelenberg, René

    2015-01-01

    In 2 experiments we investigated the efficacy of self-paced study in multitrial learning. In Experiment 1, native speakers of English studied lists of Dutch-English word pairs under 1 of 4 imposed fixed presentation rate conditions (24 × 1 s, 12 × 2 s, 6 × 4 s, or 3 × 8 s) and a self-paced study condition. Total study time per list was equated for…

  1. PACE: A Browsable Graphical Interface.

    Science.gov (United States)

    Beheshti, Jamshid; And Others

    1996-01-01

    Describes PACE (Public Access Catalogue Extension), an alternative interface designed to enhance online catalogs by simulating images of books and library shelves to help users browse through the catalog. Results of a test in a college library against a text-based online public access catalog, including student attitudes, are described.…

  2. Study on the overcurrent character analysis and its protective system of underground LV distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.; Shi, Z.; Yang, Y.; Shi, W.; Wei, H.; Zhai, S.; Xie, H. [Taiyuan University of Technology, Taiyuan (China)

    2001-02-01

    The overcurrent fault characteristics in underground LV cable distribution networks is analysed and the fundamental principle of overcurrent protective system is described in this paper. The emphasis is paid to the determination of the characteristic curves of phase-sensitive symmetrical short-circuit protection, the design of negative-sequence current filter and the definition of the mathematical model of overload. Besides, the hardware block diagram and the software flowchart of the protective system, which is controlled by a single chip microcomputer, is also introduced in the paper. The protective system was tested before being applied to the underground LV distribution networks. The results obtained are in conformity with the design specification. It has been verified that the protective distance is extended and the protective sensitivity is improved with the protective system. The field experience has shown that the protective system is stable and reliable, and will be of great application value in the mining industry. 7 refs., 5 figs., 2 tabs.

  3. Serological survey of Toxoplasma gondii, Dirofilaria immitis, Feline Immunodeficiency Virus (FIV) and Feline Leukemia Virus (FeLV) infections in pet cats in Bangkok and vicinities, Thailand.

    Science.gov (United States)

    Sukhumavasi, Woraporn; Bellosa, Mary L; Lucio-Forster, Araceli; Liotta, Janice L; Lee, Alice C Y; Pornmingmas, Pitcha; Chungpivat, Sudchit; Mohammed, Hussni O; Lorentzen, Leif; Dubey, J P; Bowman, Dwight D

    2012-08-13

    The seroprevalence of Toxoplasma gondii, Dirofilaria immitis (heartworm), feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infections was examined using serum or plasma samples from 746 pet cats collected between May and July 2009 from clinics and hospitals located in and around Bangkok, Thailand. The samples were tested for heartworm, FIV, and FeLV using a commercial ELISA. Of the 746 samples, 4.6% (34/746) were positive for heartworm antigen, 24.5% (183/746) had circulating FeLV antigen, and 20.1% (150/746) had antibodies against FIV. In addition, the first 348 submitted samples were tested for T. gondii antibodies using a modified agglutination test (MAT, cut off 1:25); 10.1% (35/348) were seropositive. Of the 348 cats sampled for all four pathogens, 11, 10, and 1 were positive for T. gondii antibodies and FIV antibodies, FeLV antigen, or D. immitis antigen, respectively. Of the 35 T. gondii-seropositive cats, 42.9% (15/35) were co-infected with at least one of the other three pathogens. The presence of antibodies to FIV was significantly associated with both age and gender, while FeLV antigen presence was only associated with age. In the case of FIV, males were twice as likely to be infected as females, and cats over 10 years of age were 13.5 times more likely to be infected than cats less than 1 year of age. FeLV antigen was more common in younger cats, with cats over 10 years of age being 10 times less likely to be FeLV positive than cats under 1 year of age. This is the first survey for these four pathogens affecting feline health in Thailand. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Quantitative Differentiation of LV Myocardium with and without Layer-Specific Fibrosis Using MRI in Hypertrophic Cardiomyopathy and Layer-Specific Strain TTE Analysis.

    Science.gov (United States)

    Funabashi, Nobusada; Takaoka, Hiroyuki; Ozawa, Koya; Kamata, Tomoko; Uehara, Masae; Komuro, Issei; Kobayashi, Yoshio

    2018-05-30

    To achieve further risk stratification in hypertrophic cardiomyopathy (HCM) patients, we localized and quantified layer-specific LVM fibrosis on MRI in HCM patients using regional layer-specific peak longitudinal strain (PLS) and peak circumferential strain (PCS) in LV myocardium (LVM) on speckle tracking transthoracic echocardiography (TTE). A total of 18 HCM patients (14 males; 58 ± 17 years) underwent 1.5T-MRI and TTE. PLS and PCS in each layer of the LVM (endocardium, epicardium, and whole-layer myocardium) were calculated for 17 AHA-defined lesions. MRI assessment showed that fibrosis was classified as endocardial, epicardial, or whole-layer (= either or both of these). Regional PLS was smaller in fibrotic endocardial lesions than in non-fibrotic endocardial lesions (P = 0.004). To detect LV endocardial lesions with fibrosis, ROC curves of regional PLS revealed an area under the curve (AUC) of 0.609 and a best cut-off point of 13.5%, with sensitivity of 65.3% and specificity of 54.3%. Regional PLS was also smaller in fibrotic epicardial lesions than in non-fibrotic epicardial lesions (P layer myocardium analysis, PLS was smaller in fibrotic lesions than in non-fibrotic lesions (P layer LV lesions with fibrosis, ROC curves of regional PLS revealed an AUC of 0.674 and a best cut-off point of 12.5%, with sensitivity of 79.0% and specificity of 50.7%. There were no significant differences in PCS of LV myocardium (endocardium, epicardium, and whole-layer) between fibrotic and non-fibrotic lesions. Quantitative regional PLS but not PCS in LV endocardium, epicardium, and whole-layer myocardium provides useful non-invasive information for layer-specific localization of fibrosis in HCM patients.

  5. Ni-Nanocluster Modified Black TiO2 with Dual Active Sites for Selective Photocatalytic CO2 Reduction.

    Science.gov (United States)

    Billo, Tadesse; Fu, Fang-Yu; Raghunath, Putikam; Shown, Indrajit; Chen, Wei-Fu; Lien, Hsiang-Ting; Shen, Tzu-Hsien; Lee, Jyh-Fu; Chan, Ting-Shan; Huang, Kuo-You; Wu, Chih-I; Lin, M C; Hwang, Jih-Shang; Lee, Chih-Hao; Chen, Li-Chyong; Chen, Kuei-Hsien

    2018-01-01

    One of the key challenges in artificial photosynthesis is to design a photocatalyst that can bind and activate the CO 2 molecule with the smallest possible activation energy and produce selective hydrocarbon products. In this contribution, a combined experimental and computational study on Ni-nanocluster loaded black TiO 2 (Ni/TiO 2[Vo] ) with built-in dual active sites for selective photocatalytic CO 2 conversion is reported. The findings reveal that the synergistic effects of deliberately induced Ni nanoclusters and oxygen vacancies provide (1) energetically stable CO 2 binding sites with the lowest activation energy (0.08 eV), (2) highly reactive sites, (3) a fast electron transfer pathway, and (4) enhanced light harvesting by lowering the bandgap. The Ni/TiO 2[Vo] photocatalyst has demonstrated highly selective and enhanced photocatalytic activity of more than 18 times higher solar fuel production than the commercial TiO 2 (P-25). An insight into the mechanisms of interfacial charge transfer and product formation is explored. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Physiological and perceptual responses of sedentary women while walking at a self-selected pace

    Directory of Open Access Journals (Sweden)

    Tatiane Hallage

    2007-06-01

    Full Text Available The purpose of this study was to investigate the physiological and perceptual responses of sedentary women while walking at a self-selected pace. The sample was made up of forty-one women with a median age of 32.6 ± 8.6 years. Subjects underwent an incremental test until exhaustion on a treadmill in order to determine their maximum physiological and perceptual responses. The subjects then a 20-minute walking test at their self-selected pace to determine physiological and perceptual responses. Descriptive analysis was in the form of measures of central tendency, variability and relative frequency. Mean exercise intensity during the walking bout was 57.3 ± 12.1% of peak oxygen consumption (VO2peak and 74.4 ± 9.3% of peak heart rate (HRpeak, corresponding to 88.4 ± 19.8% and 85.6 ± 21.6% of the fi gures obtained at ventilatory threshold (VT, respectively. Nevertheless, the rating of perceived effort (RPE and affective valence (AV during the walking session returned mean values of 11.9 ± 2.1 and 2.4 ± 2.0, which correspond to 100.7 ± 20.0% and 96.0 ± 2.0% of the fi gures obtained at VT, respectively. In conclusion, the exercise intensity that was self-selected by this group of sedentary women meets current recommendations for moderate intensity exercise and was associated with increased pleasure.RESUMO O objetivo desse estudo foi verifi car os parâmetros fi siológicos e perceptivos durante a realização de caminhada de intensidade preferida por mulheres adultas, previamente sedentárias. Foram investigados 41 sujeitos (idade 32,6 ± 8,6 anos, os quais realizaram, inicialmente, um teste de esteira incremental até a exaustão para a determinação de respostas fi siológicas e perceptivas máximas e, posteriormente, um teste de caminhada em esteira por 20 minutos em uma intensidade auto-selecionada, no qual parâmetros fi siológicos e perceptivos foram obtidos. Medidas de tendência central e variabilidade foram empregadas para a an

  7. Establishment of a novel feline leukemia virus (FeLV)-negative B-cell cell line from a cat with B-cell lymphoma.

    Science.gov (United States)

    Mochizuki, Hiroyuki; Takahashi, Masashi; Nishigaki, Kazuo; Ide, Tetsuya; Goto-Koshino, Yuko; Watanabe, Shinya; Sato, Hirofumi; Sato, Masahiko; Kotera, Yukiko; Fujino, Yasuhito; Ohno, Koichi; Uchida, Kazuyuki; Tsujimoto, Hajime

    2011-04-15

    We established a novel feline B-cell line, MS4, from the neoplastic pleural effusion of a cat with cutaneous B-cell lymphoma. Immunophenotype staining of the MS4 cells was positive for CD20, CD79α, and IgA and negative for CD3, CD4, CD5, CD8α, CD18, CD21, CD22, IgM, IgG, Ig light chain, and MHC class II. PCR analysis for immunoglobulin heavy chain gene rearrangements revealed a monoclonal rearrangement, whereas no clonal rearrangement of the T-cell receptor γ gene was detected. Southern blotting with an exogenous feline leukemia virus (FeLV) U3 probe revealed no integration of exogenous FeLV provirus. The MS4 cell line is the first FeLV-negative feline B-cell lymphoma cell line, and may be used to investigate the pathogenesis of spontaneously occurring feline lymphoma and the development of new therapies. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Application of PACE Principles for Population Health Management of Frail Older Adults.

    Science.gov (United States)

    Stefanacci, Richard G; Reich, Shelley; Casiano, Alex

    2015-10-01

    To determine which practices would have the most impact on reducing hospital and emergency department admissions and nursing home placement among older adults with multiple comorbid conditions, a literature search and survey were conducted to identify and prioritize comprehensive care principles as practiced in the Program of All-inclusive Care for the Elderly (PACE). PACE medical directors and members of the PACE interdisciplinary team (IDT) were surveyed to gain their insights on the most impactful practices, which were identified as: End-of-Life Management, Caregiver Support, Management of Red Flags, Medication Management, Participant and Caregiver Health Care System Literacy, and Care Coordination. In addition, this research evaluated measures that could be used to assess an organization's level of success with regard to each of the 6 PACE practices identified. The results reported in this article, found through a survey with PACE medical directors and IDT members concerning effective interventions, can be viewed as strategies to improve care for older adults, enabling them to maintain their independence in the community, avoid the expense of facility-based care, and enhance their quality of life.

  9. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yu; Wang Yuxia; Chen Lei [School of Pharmaceutical Science and Technology, Tianjin University, Tianjin 300072 (China); Wan Qianhong, E-mail: qhwan@tju.edu.cn [School of Pharmaceutical Science and Technology, Tianjin University, Tianjin 300072 (China)

    2012-02-15

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 {mu}g/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 {mu}g/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high

  10. New Fukui, dual and hyper-dual kernels as bond reactivity descriptors.

    Science.gov (United States)

    Franco-Pérez, Marco; Polanco-Ramírez, Carlos-A; Ayers, Paul W; Gázquez, José L; Vela, Alberto

    2017-06-21

    We define three new linear response indices with promising applications for bond reactivity using the mathematical framework of τ-CRT (finite temperature chemical reactivity theory). The τ-Fukui kernel is defined as the ratio between the fluctuations of the average electron density at two different points in the space and the fluctuations in the average electron number and is designed to integrate to the finite-temperature definition of the electronic Fukui function. When this kernel is condensed, it can be interpreted as a site-reactivity descriptor of the boundary region between two atoms. The τ-dual kernel corresponds to the first order response of the Fukui kernel and is designed to integrate to the finite temperature definition of the dual descriptor; it indicates the ambiphilic reactivity of a specific bond and enriches the traditional dual descriptor by allowing one to distinguish between the electron-accepting and electron-donating processes. Finally, the τ-hyper dual kernel is defined as the second-order derivative of the Fukui kernel and is proposed as a measure of the strength of ambiphilic bonding interactions. Although these quantities have never been proposed, our results for the τ-Fukui kernel and for τ-dual kernel can be derived in zero-temperature formulation of the chemical reactivity theory with, among other things, the widely-used parabolic interpolation model.

  11. Computerized analysis of the 12-lead electrocardiogram to identify epicardial ventricular tachycardia exit sites.

    Science.gov (United States)

    Yokokawa, Miki; Jung, Dae Yon; Joseph, Kim K; Hero, Alfred O; Morady, Fred; Bogun, Frank

    2014-11-01

    Twelve-lead electrocardiogram (ECG) criteria for epicardial ventricular tachycardia (VT) origins have been described. In patients with structural heart disease, the ability to predict an epicardial origin based on QRS morphology is limited and has been investigated only for limited regions in the heart. The purpose of this study was to determine whether a computerized algorithm is able to accurately differentiate epicardial vs endocardial origins of ventricular arrhythmias. Endocardial and epicardial pace-mapping were performed in 43 patients at 3277 sites. The 12-lead ECGs were digitized and analyzed using a mixture of gaussian model (MoG) to assess whether the algorithm was able to identify an epicardial vs endocardial origin of the paced rhythm. The MoG computerized algorithm was compared to algorithms published in prior reports. The computerized algorithm correctly differentiated epicardial vs endocardial pacing sites for 80% of the sites compared to an accuracy of 42% to 66% of other described criteria. The accuracy was higher in patients without structural heart disease than in those with structural heart disease (94% vs 80%, P = .0004) and for right bundle branch block (82%) compared to left bundle branch block morphologies (79%, P = .001). Validation studies showed the accuracy for VT exit sites to be 84%. A computerized algorithm was able to accurately differentiate the majority of epicardial vs endocardial pace-mapping sites. The algorithm is not region specific and performed best in patients without structural heart disease and with VTs having a right bundle branch block morphology. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Echo determinants of dyssynchrony (atrioventricular and inter- and intraventricular) and predictors of response to cardiac resynchronization therapy.

    Science.gov (United States)

    Kapetanakis, Stamatis; Bhan, Amit; Monaghan, Mark J

    2008-10-01

    Cardiac resynchronization therapy (CRT) has revolutionized not only the treatment of chronic heart failure but also how we assess left ventricular (LV) dysfunction on echo. Increasingly, it has become clear that identifying and quantifying delays in events during the cardiac cycle is an important assessment in LV dysfunction as it has prognostic implications for patients undergoing CRT. The delays in atrioventricular, right-to-left ventricular, and LV segmental contraction have been shown to be important components in cardiac performance, and this review provides an overview of the commonest methods used for these assessments and their implications for selecting patients for biventricular pacing.

  13. Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs. Electrophysiological remodeling.

    Science.gov (United States)

    Elvan, A; Wylie, K; Zipes, D P

    1996-12-01

    We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.

  14. Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

    International Nuclear Information System (INIS)

    Barnett, Joseph; Tavare, Aniket N.; Khan, Sajid; Saini, Ashish; Creer, Dean D.; Hare, Samanjit S.

    2017-01-01

    PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G   core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

  15. Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, Joseph; Tavare, Aniket N. [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom); Khan, Sajid [Royal Free London NHS Foundation Trust, Department of Respiratory Medicine, Barnet Hospital (United Kingdom); Saini, Ashish [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom); Creer, Dean D. [Royal Free London NHS Foundation Trust, Department of Respiratory Medicine, Barnet Hospital (United Kingdom); Hare, Samanjit S., E-mail: samhare@nhs.net [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom)

    2017-05-15

    PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G   core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

  16. Visual aided pacing in respiratory maneuvers

    Energy Technology Data Exchange (ETDEWEB)

    Rambaudi, L R [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Rossi, E [Catedra de Bioingenieria II (Argentina); Mantaras, M C [Catedra de Bioingenieria II (Argentina); Perrone, M S [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Siri, L Nicola [Catedra de Bioingenieria II (Argentina)

    2007-11-15

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display.

  17. Visual aided pacing in respiratory maneuvers

    International Nuclear Information System (INIS)

    Rambaudi, L R; Rossi, E; Mantaras, M C; Perrone, M S; Siri, L Nicola

    2007-01-01

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display

  18. The Influence of a Pacesetter on Psychological Responses and Pacing Behavior during a 1600 m Run

    Directory of Open Access Journals (Sweden)

    Christopher L. Fullerton, Andrew M. Lane, Tracey J. Devonport

    2017-12-01

    Full Text Available This study compared the effects of following a pacer versus following a self-paced plan on psychological responses and pacing behavior in well-trained distance runners. Pacing in the present study was individually tailored where each participant developed a personal strategy to ensure their goal time was achieved. We expected that following a pacer would associate with goal achievement, higher pre-run confidence, positive emotions and lower perceived exertion during performance. In a mixed-design repeated-measures study, nineteen well-trained runners completed two 1600m running time trials. Ten runners had a pacer (paced group who supported their individual pacing strategy, and nine participants self-paced running alone (control group. Both groups could check pace using their wrist watch. In contrast to our expectation, results indicated that the paced group reported higher pre-run anxiety with no significant differences in finish time, goal confidence, goal difficulty, perceived exertion, and self-rated performance between groups. We suggest that following a pacer is a skill that requires learning. Following a personalised pacer might associate with higher anxiety due to uncertainty in being able to keep up with the pacer and public visibility of dropping behind, something that is not so observable in a self-paced run completed alone. Future research should investigate mechanisms associated with effective pacing.

  19. Dual Mode Fluorophore-Doped Nickel Nitrilotriacetic Acid-Modified Silica Nanoparticles Combine Histidine-Tagged Protein Purification with Site-Specific Fluorophore Labeling

    OpenAIRE

    Kim, Sung Hoon; Jeyakumar, M.; Katzenellenbogen, John A.

    2007-01-01

    We present the first example of a fluorophore-doped nickel chelate surface- modified silica nanoparticle that functions in a dual mode, combining histidine-tagged protein purification with site-specific fluorophore labeling. Tetramethylrhodamine (TMR)-doped silica nanoparticles, estimated to contain 700–900 TMRs per ca. 23-nm particle, were surface modified with nitrilotriacetic acid (NTA), producing TMR-SiO2-NTA-Ni+2. Silica-embedded TMR retains very high quantum yield, is resistant to quenc...

  20. A Monetary Reward Alters Pacing but Not Performance in Competitive Cyclists.

    Science.gov (United States)

    Skorski, Sabrina; Thompson, Kevin G; Keegan, Richard J; Meyer, Tim; Abbiss, Chris R

    2017-01-01

    Money has frequently been used as an extrinsic motivator since it is assumed that humans are willing to invest more effort for financial reward. However, the influence of a monetary reward on pacing and performance in trained athletes is not well-understood. Therefore, the aim of this study was to analyse the influence of a monetary reward in well-trained cyclists on their pacing and performance during short and long cycling time trials (TT). Twentythree cyclists (6 ♀, 17 ♂) completed 4 self-paced time trials (TTs, 2 short: 4 km and 6 min; 2 long: 20 km and 30 min); in a randomized order. Participants were separated into parallel, non-randomized "rewarded" and "non-rewarded" groups. Cyclists in the rewarded group received a monetary reward based on highest mean power output across all TTs. Cyclists in the non-rewarded group did not receive a monetary reward. Overall performance was not significantly different between groups in short or long TTs ( p > 0.48). Power output showed moderatly lower effect sizes at comencement of the short TTs ( P meandiff = 36.6 W; d > 0.44) and the 20 km TT ( P meandiff = 22.6 W; d = 0.44) in the rewarded group. No difference was observed in pacing during the 30 min TT ( p = 0.95). An external reward seems to have influenced pacing at the commencement of time trials. Participants in the non-rewarded group adopted a typical parabolic shaped pattern, whereas participants in the rewarded group started trials more conservatively. Results raise the possibility that using money as an extrinsic reward may interfere with regulatory processes required for effective pacing.

  1. A Monetary Reward Alters Pacing but Not Performance in Competitive Cyclists

    Directory of Open Access Journals (Sweden)

    Sabrina Skorski

    2017-09-01

    Full Text Available Money has frequently been used as an extrinsic motivator since it is assumed that humans are willing to invest more effort for financial reward. However, the influence of a monetary reward on pacing and performance in trained athletes is not well-understood. Therefore, the aim of this study was to analyse the influence of a monetary reward in well-trained cyclists on their pacing and performance during short and long cycling time trials (TT. Twentythree cyclists (6 ♀, 17 ♂ completed 4 self-paced time trials (TTs, 2 short: 4 km and 6 min; 2 long: 20 km and 30 min; in a randomized order. Participants were separated into parallel, non-randomized “rewarded” and “non-rewarded” groups. Cyclists in the rewarded group received a monetary reward based on highest mean power output across all TTs. Cyclists in the non-rewarded group did not receive a monetary reward. Overall performance was not significantly different between groups in short or long TTs (p > 0.48. Power output showed moderatly lower effect sizes at comencement of the short TTs (Pmeandiff = 36.6 W; d > 0.44 and the 20 km TT (Pmeandiff = 22.6 W; d = 0.44 in the rewarded group. No difference was observed in pacing during the 30 min TT (p = 0.95. An external reward seems to have influenced pacing at the commencement of time trials. Participants in the non-rewarded group adopted a typical parabolic shaped pattern, whereas participants in the rewarded group started trials more conservatively. Results raise the possibility that using money as an extrinsic reward may interfere with regulatory processes required for effective pacing.

  2. Whole-genome sequence of Erysipelothrix larvae LV19(T) (=KCTC 33523(T)), a useful strain for arsenic detoxification, from the larval gut of the rhinoceros beetle, Trypoxylus dichotomus.

    Science.gov (United States)

    Lim, Sooyeon; Rhee, Moon-Soo; Chang, Dong-Ho; Kim, Byoung-Chan

    2016-04-10

    Erysipelothrix larvae LV19(T) was preliminary isolated from the larval gut of a rhinoceros beetle, Trypoxylus dichotomus in Korea. Here, we present the whole genome sequence of E. larvae LV19(T) strain, which consisted of 2,511,486 base pairs with a GC content of 37.4% and one plasmid. Unlike other Erysipelothrix strains (SY 1027, Fujisawa and ATCC 19414), the arsenic-resistance genes were identified in LV19(T) strain. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca²⁺-sensitive K⁺ current in miniature swine with LV hypertrophy.

    Science.gov (United States)

    Emter, Craig A; Tharp, Darla L; Ivey, Jan R; Ganjam, Venkataseshu K; Bowles, Douglas K

    2011-10-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ET(A)) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K(+) currents (I(K(+))) in coronary smooth muscle cells. Raising internal Ca(2+) from 200 to 500 nM increased Ca(2+)-sensitive K(+) current in HF-TR and control, but not HF animals. In conclusion, an ET(A)-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca(2+)-sensitive I(K(+)) was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca(2+)-sensitive I(K(+)), illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy.

  4. Effect of age and performance on pacing of marathon runners

    Directory of Open Access Journals (Sweden)

    Nikolaidis PT

    2017-08-01

    Full Text Available Pantelis Theodoros Nikolaidis,1 Beat Knechtle2,3 1Exercise Physiology Laboratory, Attiki, Greece; 2Gesundheitszentrum St. Gallen, St. Gallen, 3Institute of Primary Care, University of Zurich, Zurich, Switzerland Abstract: Pacing strategies in marathon runners have previously been examined, especially with regard to age and performance level separately. However, less information about the age × performance interaction on pacing in age-group runners exists. The aim of the present study was to examine whether runners with similar race time and at different age differ for pacing. Data (women, n=117,595; men, n=180,487 from the “New York City Marathon” between 2006 and 2016 were analyzed. A between–within subjects analysis of variance showed a large main effect of split on race speed (p<0.001, η2=0.538 with the fastest speed in the 5–10 km split and the slowest in the 35–40 km. A small sex × split interaction on race speed was found (p<0.001, η2=0.035 with men showing larger increase in speed at 5 km and women at 25 km and 40 km (end spurt. An age-group × performance group interaction on Δspeed was shown for both sexes at 5 km, 10 km, 15 km, 20 km, 25 km, 30 km, 35 km, and 40 km (p<0.001, 0.001≤η2≤0.004, where athletes in older age-groups presented a relatively more even pace compared with athletes in younger age-groups, a trend that was more remarkable in the relatively slow performance groups. So far, the present study is the first one to observe an age × performance interaction on pacing; ie, older runners pace differently (smaller changes than younger runners with similar race time. These findings are of great practical interest for coaches working with marathon runners of different age, but similar race time. Keywords: running, master athlete, endurance, aerobic capacity, fatigue, gender, race time

  5. The Platform-Aware Compilation Environment (PACE)

    Science.gov (United States)

    2012-09-01

    The PACE Project provided full or partial support for the following graduate students: 1. Raj Barik (Rice) 2. Thomas Barr (Rice) 3...University, Houston, TX, Technical Report CS TR11-03, October 20, 2011. [7] Rajkishore Barik , Jisheng Zhao, and Vivek Sarkar, "Efficient Selection

  6. Extinction in the Galaxy from surface brightnesses of ESO-LV galaxies : Testing "standard" extinction maps

    NARCIS (Netherlands)

    Choloniewski, J.; Valentijn, E. A.

    A new method for the determination of the extinction in the Galaxy is proposed. The method uses surface brightnesses of external galaxies in the B and R-bands. The observational data have been taken from the ESO-LV galaxy catalog. As a first application of our model we derive the ratio of R-band to

  7. DUAL TIMELIKE NORMAL AND DUAL TIMELIKE SPHERICAL CURVES IN DUAL MINKOWSKI SPACE

    OpenAIRE

    ÖNDER, Mehmet

    2009-01-01

    Abstract: In this paper, we give characterizations of dual timelike normal and dual timelike spherical curves in the dual Minkowski 3-space and we show that every dual timelike normal curve is also a dual timelike spherical curve. Keywords: Normal curves, Dual Minkowski 3-Space, Dual Timelike curves. Mathematics Subject Classifications (2000): 53C50, 53C40. DUAL MINKOWSKI UZAYINDA DUAL TIMELIKE NORMAL VE DUAL TIMELIKE KÜRESEL EĞRİLER Özet: Bu çalışmada, dual Minkowski 3-...

  8. 77 FR 21620 - Notice of the Buy America Waiver Request for Vossloh 101-LV Concrete Ties

    Science.gov (United States)

    2012-04-10

    ... the Buy America Waiver Request for Vossloh 101-LV Concrete Ties AGENCY: Federal Railroad... concrete ties, which contain certain components not manufactured in the United States. In furtherance of... concrete ties. FRA has received this request from the four States for the following projects: (a) The...

  9. Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery.

    Science.gov (United States)

    Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar

    2018-06-14

    The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.

  10. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  11. Unilateral Laryngeal Pacing System and Its Functional Evaluation

    Directory of Open Access Journals (Sweden)

    Taiping Zeng

    2017-01-01

    Full Text Available Goal. To establish a reliable instrumental system for synchronized reactivation of a unilaterally paralyzed vocal fold and evaluate its functional feasibility. Methods. Unilateral vocal fold paralysis model was induced by destruction of the left recurrent laryngeal nerve (RLN in anesthetized dogs. With a micro controller-based electronic system, electromyography (EMG signals from cricothyroid (CT muscle on the ipsilateral side were recorded and used to trigger pacing of paralyzed vocalis muscles. The dynamic movement of vocal folds was continuously monitored using an endoscope, and the opening and closing of the glottis were quantified with customized imaging processing software. Results. The recorded video images showed that left side vocal fold was obviously paralyzed after destructing the RLN. Using the pacing system with feedback triggering EMG signals from the ipsilateral CT muscle, the paralyzed vocal fold was successfully reactivated, and its movement was shown to be synchronized with the healthy side. Significance. The developed unilateral laryngeal pacing system triggered by EMG from the ipsilateral side CT muscle could be successfully used in unilateral vocal fold paralysis with the advantage of avoiding disturbance to the healthy side muscles.

  12. The pace and shape of ageing

    DEFF Research Database (Denmark)

    Baudisch, Annette

    2011-01-01

    exhibits negligible ageing - contrary to the commonly held view that long-lived species are good candidates for negligible ageing. 5.Analysis of species in pace-shape space provides a tool to identify key determinants of the evolution of ageing for species across the tree of life....

  13. Identification of a C-type lectin with antiviral and antibacterial activity from pacific white shrimp Litopenaeus vannamei.

    Science.gov (United States)

    Li, Ming; Li, Chaozheng; Ma, Chunxia; Li, Haoyang; Zuo, Hongliang; Weng, Shaoping; Chen, Xiaohan; Zeng, Digang; He, Jianguo; Xu, Xiaopeng

    2014-10-01

    C-type lectins (CTLs) play crucial roles in innate immune responses in invertebrates by recognizing and eliminating microinvaders. In this study, a CTL from pacific white shrimp Litopenaeus vannamei (LvCTL3) was identified. LvCTL3 contains a single C-type lectin-like domain (CTLD), which shows similarities to those of other shrimp CTLs and has a mutated 'EPD' motif in Ca(2+)-binding site 2. LvCTL3 mRNA can be detected in all tested tissues and expression of LvCTL3 in gills was up-regulated after Lipopolysaccharides, poly (I:C), Vibrio parahaemolyticus and white spot syndrome virus (WSSV) challenges, suggesting activation responses of LvCTL3 to bacterial, virus and immune stimulant challenges. The 5'flanking regulatory region of LvCTL3 was cloned and we identified a NF-κB binding motif in the LvCTL3 promoter region. Dual-luciferase reporter assays indicated that over-expression of L. vannamei dorsal can dramatically up regulate the promoter activity of LvCTL3, suggesting that LvCTL3 expression could be regulated through NF-κB signaling pathway. As far as we know, this is the first report on signaling pathway involve in shrimp CTLs expression. The recombinant LvCTL3 protein was expressed in Escherichia coli and purified by Ni-affinity chromatography. The purified LvCTL3 can agglutinate Gram-negative microbe Vibrio alginolyticus and V. parahaemolyticus and Gram-positive bacteria Bacillus subtilis in the presence of calcium ions, but cannot agglutinate Gram-positive bacteria Streptococcus agalactiae. The agglutination activity of LvCTL3 was abolished when Ca(2+) was chelated with EDTA, suggesting the function of LvCTL3 is Ca(2+)-dependent. In vivo challenge experiments showed that the recombinant LvCTL3 protein can significantly reduce the mortalities of V. parahemolyticus and WSSV infection, indicating LvCTL3 might play significant roles in shrimp innate immunity defense against bacterial and viral infection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Permanent pacing in infants and children: A single center experience in implantation and follow up

    Directory of Open Access Journals (Sweden)

    Rania Samir

    2011-09-01

    Conclusion: Permanent pacing in pediatric age group is relatively safe. However, there is substantial higher incidence of suboptimal pacing parameters and pacing system failures especially in younger and smaller children. Epicardial steroid eluting leads are comparable to endocardial steroid eluting leads in performance.

  15. Lentivector Integration Sites in Ependymal Cells From a Model of Metachromatic Leukodystrophy: Non-B DNA as a New Factor Influencing Integration

    Science.gov (United States)

    McAllister, Robert G; Liu, Jiahui; Woods, Matthew W; Tom, Sean K; Rupar, C Anthony; Barr, Stephen D

    2014-01-01

    The blood–brain barrier controls the passage of molecules from the blood into the central nervous system (CNS) and is a major challenge for treatment of neurological diseases. Metachromatic leukodystrophy is a neurodegenerative lysosomal storage disease caused by loss of arylsulfatase A (ARSA) activity. Gene therapy via intraventricular injection of a lentiviral vector is a potential approach to rapidly and permanently deliver therapeutic levels of ARSA to the CNS. We present the distribution of integration sites of a lentiviral vector encoding human ARSA (LV-ARSA) in murine brain choroid plexus and ependymal cells, administered via a single intracranial injection into the CNS. LV-ARSA did not exhibit a strong preference for integration in or near actively transcribed genes, but exhibited a strong preference for integration in or near satellite DNA. We identified several genomic hotspots for LV-ARSA integration and identified a consensus target site sequence characterized by two G-quadruplex-forming motifs flanking the integration site. In addition, our analysis identified several other non-B DNA motifs as new factors that potentially influence lentivirus integration, including human immunodeficiency virus type-1 in human cells. Together, our data demonstrate a clinically favorable integration site profile in the murine brain and identify non-B DNA as a potential new host factor that influences lentiviral integration in murine and human cells. PMID:25158091

  16. Selection of permanent pacing position of cardiac ventricle in patients with complete right bundle branch block

    International Nuclear Information System (INIS)

    Yang Minquan; Zhou Jun; Zhu Yan; Wang Jin; Rong Xin; Zhang Xiaoyi

    2005-01-01

    Objective: To find out the optimal pacing localization by comparing different pacing positions of the right ventricle in brady-cardiacarrhythmia patients with complete right bundle branch block. Methods: DDD type of double lumen permanent pacemaker was implanted in each of the 8 cases of sick sinus syndrome (SSS) and/or III degree atrioventricular block (III degree AVB) with complete right bundle branch block in normal heart function or class I. For each patient, four pacing positions in right ventricle were compared and the QRS pacing durations were recorded. The position with the shortest the QRS duration was chosen as the permanent pacing position. Heart function, chest X-rays and left ventricle ejection fraction (LVEF) were followed up after the operation. Results: In all the 8 cases, the posterior septum of the right ventricle were chosen as the permanent pacing position, with the shorter pacing QRS duration than that of pre-operation (P<0.05) and other pacing positions of the right ventricle. All parameters of this permanent pacing position were within the normal range. During the follow-up of 6-36 months, no abnormity was found in cardiac functions. Conclusion: In brady-cardiacarrhythmia patients with complete right bundle branch block, the implantation of permanent pacemaker should be at the junction region of inlet and outlet tracts, of the posterior septum of the right ventricle with ideal physiological function. (authors)

  17. Surface glycosaminoglycans mediate adherence between HeLa cells and Lactobacillus salivarius Lv72.

    Science.gov (United States)

    Martín, Rebeca; Martín, Carla; Escobedo, Susana; Suárez, Juan E; Quirós, Luis M

    2013-09-17

    The adhesion of lactobacilli to the vaginal surface is of paramount importance to develop their probiotic functions. For this reason, the role of HeLa cell surface proteoglycans in the attachment of Lactobacillus salivarius Lv72, a mutualistic strain of vaginal origin, was investigated. Incubation of cultures with a variety of glycosaminoglycans (chondroitin sulfate A and C, heparin and heparan sulfate) resulted in marked binding interference. However, no single glycosaminoglycan was able to completely abolish cell binding, the sum of all having an additive effect that suggests cooperation between them and recognition of specific adhesins on the bacterial surface. In contrast, chondroitin sulfate B enhanced cell to cell attachment, showing the relevance of the stereochemistry of the uronic acid and the sulfation pattern on binding. Elimination of the HeLa surface glycosaminoglycans with lyases also resulted in severe adherence impairment. Advantage was taken of the Lactobacillus-glycosaminoglycans interaction to identify an adhesin from the bacterial surface. This protein, identify as a soluble binding protein of an ABC transporter system (OppA) by MALDI-TOF/(MS), was overproduced in Escherichia coli, purified and shown to interfere with L. salivarius Lv72 adhesion to HeLa cells. These data suggest that glycosaminoglycans play a fundamental role in attachment of mutualistic bacteria to the epithelium that lines the cavities where the normal microbiota thrives, OppA being a bacterial adhesin involved in the process.

  18. Modeling parameters that characterize pacing of elite female 800-m freestyle swimmers.

    Science.gov (United States)

    Lipińska, Patrycja; Allen, Sian V; Hopkins, Will G

    2016-01-01

    Pacing offers a potential avenue for enhancement of endurance performance. We report here a novel method for characterizing pacing in 800-m freestyle swimming. Websites provided 50-m lap and race times for 192 swims of 20 elite female swimmers between 2000 and 2013. Pacing for each swim was characterized with five parameters derived from a linear model: linear and quadratic coefficients for effect of lap number, reductions from predicted time for first and last laps, and lap-time variability (standard error of the estimate). Race-to-race consistency of the parameters was expressed as intraclass correlation coefficients (ICCs). The average swim was a shallow negative quadratic with slowest time in the eleventh lap. First and last laps were faster by 6.4% and 3.6%, and lap-time variability was ±0.64%. Consistency between swimmers ranged from low-moderate for the linear and quadratic parameters (ICC = 0.29 and 0.36) to high for the last-lap parameter (ICC = 0.62), while consistency for race time was very high (ICC = 0.80). Only ~15% of swimmers had enough swims (~15 or more) to provide reasonable evidence of optimum parameter values in plots of race time vs. each parameter. The modest consistency of most of the pacing parameters and lack of relationships between parameters and performance suggest that swimmers usually compensated for changes in one parameter with changes in another. In conclusion, pacing in 800-m elite female swimmers can be characterized with five parameters, but identifying an optimal pacing profile is generally impractical.

  19. Efficient Dual-Site Carbon Monoxide Electro-Catalysts via Interfacial Nano-Engineering

    Science.gov (United States)

    Liu, Zhen; Huang, Zhongyuan; Cheng, Feifei; Guo, Zhanhu; Wang, Guangdi; Chen, Xu; Wang, Zhe

    2016-01-01

    Durable, highly efficient, and economic sound electrocatalysts for CO electrooxidation (COE) are the emerging key for wide variety of energy solutions, especially fuel cells and rechargeable metal−air batteries. Herein, we report the novel system of nickel−aluminum double layered hydroxide (NiAl-LDH) nanoplates on carbon nanotubes (CNTs) network. The formulation of such complexes system was to be induced through the assistance of gold nanoparticles in order to form dual-metal active sites so as to create a extended Au/NiO two phase zone. Bis (trifluoromethylsulfonyl)imide (NTf2) anion of ionic liquid electrolyte was selected to enhance the CO/O2 adsorption and to facilitate electro-catalyzed oxidation of Ni (OH)2 to NiOOH by increasing the electrophilicity of catalytic interface. The resulting neutral catalytic system exhibited ultra-high electrocatalytic activity and stability for CO electrooxidation than commercial and other reported precious metal catalysts. The turnover frequency (TOF) of the LDH-Au/CNTs COE catalyst was much higher than the previous reported other similar electrocatalysts, even close to the activity of solid-gas chemical catalysts at high temperature. Moreover, in the long-term durability testing, the negligible variation of current density remains exsisting after 1000 electrochemistry cycles. PMID:27650532

  20. Sawtooth Pacing by Real-Time Auxiliary Power Control in a Tokamak Plasma

    International Nuclear Information System (INIS)

    Goodman, T. P.; Felici, F.; Sauter, O.; Graves, J. P.

    2011-01-01

    In the standard scenario of tokamak plasma operation, sawtooth crashes are the main perturbations that can trigger performance-degrading, and potentially disruption-generating, neoclassical tearing modes. This Letter demonstrates sawtooth pacing by real-time control of the auxiliary power. It is shown that the sawtooth crash takes place in a reproducible manner shortly after the removal of that power, and this can be used to precisely prescribe, i.e., pace, the individual sawteeth. In combination with preemptive stabilization of the neoclassical tearing modes, sawtooth pacing provides a new sawtooth control paradigm for improved performance in burning plasmas.

  1. Optimal pacing strategy: from theoretical modelling to reality in 1500-m speed skating.

    Science.gov (United States)

    Hettinga, F J; De Koning, J J; Schmidt, L J I; Wind, N A C; Macintosh, B R; Foster, C

    2011-01-01

    Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing profile. Seven national-level speed-skaters performed a SP 1500-m which was analysed by obtaining velocity (every 100 m) and body position (every 200 m) with video to calculate total mechanical power output. Together with gross efficiency and aerobic kinetics, obtained in separate trials, data were used to calculate aerobic and anaerobic power output profiles. An energy flow model was applied to SP, simulating a range of pacing strategies, and a theoretically optimal pacing profile was imposed in a second race (IM). Final time for IM was ∼2 s slower than SP. Total power distribution per lap differed, with a higher power over the first 300 m for IM (637.0 (49.4) vs 612.5 (50.0) W). Anaerobic parameters did not differ. The faster first lap resulted in a higher aerodynamic drag coefficient and perhaps a less effective push-off. Experienced athletes have a well-developed performance template, and changing pacing strategy towards a theoretically optimal fast start protocol had negative consequences on speed-skating technique and did not result in better performance.

  2. A Pilot Study on the Effects of Slow Paced Breathing on Current Food Craving.

    Science.gov (United States)

    Meule, Adrian; Kübler, Andrea

    2017-03-01

    Heart rate variability biofeedback (HRV-BF) involves slow paced breathing (approximately six breaths per minute), thereby maximizing low-frequent heart rate oscillations and baroreflex gain. Mounting evidence suggests that HRV-BF promotes symptom reductions in a variety of physical and mental disorders. It may also positively affect eating behavior by reducing food cravings. The aim of the current study was to investigate if slow paced breathing can be useful for attenuating momentary food craving. Female students performed paced breathing either at six breaths per minute (n = 32) or at nine breaths per minute (n = 33) while watching their favorite food on the computer screen. Current food craving decreased during a first resting period, increased during paced breathing, and decreased during a second resting period in both conditions. Although current hunger increased in both conditions during paced breathing as well, it remained elevated after the second resting period in the nine breaths condition only. Thus, breathing rate did not influence specific food craving, but slow paced breathing appeared to have a delayed influence on state hunger. Future avenues are suggested for the study of HRV-BF in the context of eating behavior.

  3. Self-Paced Physics, Segments 24-27.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this fifth problems and solutions book used as a part of student course work. The subject matter is related to work in electric fields, potential differences, parallel plates, electric potential energies, potential gradients, capacitances, and capacitor circuits.…

  4. Self-Paced Physics, Segments 28-31.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this sixth problems and solutions book used as a part of student course work. The subject matter is related to electric currents, current densities, resistances, Ohm's law, voltages, Joule heating, electromotive forces, single loop circuits, series and parallel…

  5. Self-Paced Physics, Segments 37-40.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this eighth problems and solutions book used as a part of course assignments. The content is related to magnetic induction, Faraday's law, induced currents, Lenz's law, induced electromotive forces, time-varying magnetic fields, self-inductance, inductors,…

  6. Lessons in Commercial PACE Leadership: The Path from Legislation to Launch

    Energy Technology Data Exchange (ETDEWEB)

    Leventis, G; Schwartz, LC; Kramer, C; Deason, J

    2018-02-27

    Nonresidential buildings are responsible for over a quarter of primary energy consumption in the United States. Efficiency improvements in these buildings could result in significant energy and utility bill savings. To unlock those potential savings, a number of market barriers to energy efficiency must be addressed. Commercial Property Assessed Clean Energy (C-PACE) financing programs can help overcome several of these barriers with minimal investment from state and local governments. With programs established or under development in 22 states, and at least $521 million in investments so far, other state and local governments are interested in bringing the benefits of C-PACE to their jurisdictions. Lessons in Commercial PACE Leadership: The Path from Legislation to Launch, aims to fast track the set-up of C-PACE programs for state and local governments by capturing the lessons learned from leaders. The report examines the list of potential program design options and important decision points in setting up a C-PACE program, tradeoffs for available options, and experiences of stakeholders that have gone through (or are going through) the process. C-PACE uses a voluntary special property assessment to facilitate energy and other improvements in commercial buildings. For example: - Long financing terms under C-PACE can produce cash flow-positive -- projects to help overcome a focus on short paybacks. - Payment obligations can transfer to subsequent owners, mitigating concern about investing in improvements for a building that may be sold before the return on the investment is fully realized. - 100% of both hard and soft costs can be financed. To capture the benefits of C-PACE financing, state and local governments must navigate numerous decision points and engage with stakeholders to set-up or join a program. Researchers interviewed experts (including state and local sponsors, program administrators, capital providers and industry experts) on their lessons learned and

  7. Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

    Directory of Open Access Journals (Sweden)

    Janice Swampillai, MD

    2011-01-01

    Full Text Available Implantation of a transvenous endocardial pacing lead in the right ventricle is contra-indicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approach is minimally invasive, provides effective ventricular stimulation with low pacing threshold and stable lead position, and is a feasible option when transvenous right ventricular pacing is not possible.

  8. Neurogenesis in the olfactory bulb induced by paced mating in the female rat is opioid dependent.

    Directory of Open Access Journals (Sweden)

    Marianela Santoyo-Zedillo

    Full Text Available The possibility to control the rate of sexual stimulation that the female rat receives during a mating encounter (pacing increases the number of newborn neurons that reach the granular layer of the accessory olfactory bulb (AOB. If females mate repeatedly, the increase in the number of neurons is observed in other regions of the AOB and in the main olfactory bulb (MOB. It has also been shown that paced mating induces a reward state mediated by opioids. There is also evidence that opioids modulate neurogenesis. In the present study, we evaluated whether the opioid receptor antagonist naloxone (NX could reduce the increase in neurogenesis in the AOB induced by paced mating. Ovariectomized female rats were randomly divided in 5 different groups: 1 Control (not mated treated with saline, 2 control (not mated treated with naloxone, 3 females that mated without controlling the sexual interaction (no-pacing, 4 females injected with saline before pacing the sexual interaction and 5 females injected with NX before a paced mating session. We found, as previously described, that paced mating induced a higher number of new cells in the granular layer of the AOB. The administration of NX before paced mating, blocked the increase in the number of newborn cells and prevented these cells from differentiating into neurons. These data suggest that opioid peptides play a fundamental role in the neurogenesis induced by paced mating in female rats.

  9. On the pace of fertility decline in sub-Saharan Africa

    OpenAIRE

    David Shapiro; Andrew Hinde

    2017-01-01

    Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa.Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world.Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they ...

  10. Pacing, Pixels, and Paper: Flexibility in Learning Words from Flashcards

    Directory of Open Access Journals (Sweden)

    Kara Sage

    2016-08-01

    Full Text Available The present study focused on how self-control over pace might help learners successfully extract information from digital learning aids. Past research has indicated that too much control over pace can be overwhelming, but too little control over pace can be ineffective. Within the popular self-testing domain of flashcards, we sought to elucidate the optimal level of user control for digital learning and compare learning outcomes between paper and digital flashcards. College students learned vocabulary from paper flashcards or one of several digital flashcard versions and were scored on their memory recall and asked about their perceptions of the learning process. With digital flashcards, students were randomly assigned to an automatic slideshow of cards with no user control, automatic slideshow with pre-set pauses, automatic slideshow where users could press the spacebar to pause at any time, or a self-paced slideshow with complete user control. Users reported feeling more in control when indeed having some control, but ultimately memory recall, cognitive load, and satisfaction were similar across the five versions. However, memory recall was positively related to user satisfaction with their specific flashcard set, and negatively related to users’ perceived mental effort and difficulty. Notably, whether paper or digital, students showed individual variability in how they advanced through the words. This research adds to the educational literature by suggesting that paper and digital flashcards are equally viable options for students. Given differences between individual users and the connection between satisfaction and recall, individualistic options that offer, but do not force, some control over pace seem ideal. Paper flashcards may already include such options, and e-flashcards should offer similar adaptive features to appeal to a wide variety of users.

  11. Pacing and awareness: brain regulation of physical activity.

    Science.gov (United States)

    Edwards, A M; Polman, R C J

    2013-11-01

    The aim of this current opinion article is to provide a contemporary perspective on the role of brain regulatory control of paced performances in response to exercise challenges. There has been considerable recent conjecture as to the role of the brain during exercise, and it is now broadly accepted that fatigue does not occur without brain involvement and that all voluntary activity is likely to be paced at some level by the brain according to individualised priorities and knowledge of personal capabilities. This article examines the role of pacing in managing and distributing effort to successfully accomplish physical tasks, while extending existing theories on the role of the brain as a central controller of performance. The opinion proposed in this article is that a central regulator operates to control exercise performance but achieves this without the requirement of an intelligent central governor located in the subconscious brain. It seems likely that brain regulation operates at different levels of awareness, such that minor homeostatic challenges are addressed automatically without conscious awareness, while larger metabolic disturbances attract conscious awareness and evoke a behavioural response. This supports the view that the brain regulates exercise performance but that the interpretation of the mechanisms underlying this effect have not yet been fully elucidated.

  12. The Explicit Determinations Of Dual Plane Curves And Dual Helices In Terms Of Its Dual Curvature And Dual Torsion

    OpenAIRE

    Lee Jae Won; Choi Jin Ho; Jin Dae Ho

    2014-01-01

    In this paper, we give the explicit determinations of dual plane curves, general dual helices and dual slant helices in terms of its dual curvature and dual torsion as a fundamental theory of dual curves in a dual 3-space

  13. Techniques for Identification of Left Ventricular Asynchrony for Cardiac Resynchronization Therapy in Heart Failure

    Directory of Open Access Journals (Sweden)

    Peter Schuster

    2005-07-01

    Full Text Available The most recent treatment option of medically refractory heart failure includes cardiac resynchronization therapy (CRT by biventricular pacing in selected patients in NYHA functional class III or IV heart failure. The widely used marker to indicate left ventricular (LV asynchrony has been the surface ECG, but seems not to be a sufficient marker of the mechanical events within the LV and prediction of clinical response. This review presents an overview of techniques for identification of left ventricular intra- and interventricular asynchrony. Both manuscripts for electrical and mechanical asynchrony are reviewed, partly predicting response to CRT. In summary there is still no gold standard for assessment of LV asynchrony for CRT, but both traditional and new echocardiographic methods have shown asynchronous LV contraction in heart failure patients, and resynchronized LV contraction during CRT and should be implemented as additional methods for selecting patients to CRT.

  14. On the pace of fertility decline in sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    David Shapiro

    2017-10-01

    Full Text Available Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa. Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world. Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they are into their fertility transition. Results: The data shows clearly that fertility decline in sub-Saharan Africa, still at a comparatively early stage, has been considerably slower than the earlier declines in Asia, Latin America and the Caribbean, and Northern Africa at comparable stages of the transition, and displays less within-region heterogeneity than the transitions in these other regions. Conclusions: The slower pace of fertility decline in sub-Saharan Africa, in conjunction with the high current fertility levels in the region, means that in the absence of policies seeking to accelerate fertility decline, sub-Saharan Africa will continue to experience rapid population growth that in turn will constrain its development. Contribution: Presentation of data in a novel way (Figures 2‒4, and associated calculations unambiguously demonstrates the slow pace of fertility decline in sub-Saharan Africa compared with other regions of the world.

  15. International piping benchmarks: Use of simplified code PACE 2

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom)

    1979-06-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  16. International piping benchmarks: Use of simplified code PACE 2

    International Nuclear Information System (INIS)

    Boyle, J.; Spence, J.; Blundell, C.

    1979-01-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  17. Potenzielle Einflussfaktoren auf Pacing im ausdauersportlichen Wettkampf

    NARCIS (Netherlands)

    Thiel, C.; de Koning, J.J.; Foster, C.

    2015-01-01

    In competitive endurance sport, athletes permanently regulate their performance to achieve the best result without threatening organismic integrity. This conscious and subconscious allocation of energy reserves in relation to an endpoint is termed pacing and depends on sport-specific experience as

  18. Regional evidence of modulation of cardiac adiponectin level in dilated cardiomyopathy: pilot study in a porcine animal model

    Directory of Open Access Journals (Sweden)

    Caselli Chiara

    2012-11-01

    Full Text Available Abstract Background The role of systemic and myocardial adiponectin (ADN in dilated cardiomyopathy is still debated. We tested the regulation of both systemic and myocardial ADN and the relationship with AMP-activated protein kinase (AMPK activity in a swine model of non-ischemic dilated cardiomyopathy. Methods and results Cardiac tissue was collected from seven instrumented adult male minipigs by pacing the left ventricular (LV free wall (180 beats/min, 3 weeks, both from pacing (PS and opposite sites (OS, and from five controls. Circulating ADN levels were inversely related to global and regional cardiac function. Myocardial ADN in PS was down-regulated compared to control (p Conclusions Paradoxically, circulating ADN did not show any cardioprotective effect, confirming its role as negative prognostic biomarker of heart failure. Myocardial ADN was reduced in PS compared to control in an AMPK-independent fashion, suggesting the occurrence of novel mechanisms by which reduced cardiac ADN levels may regionally mediate the decline of cardiac function.

  19. Self-Paced Physics, Segments 19-23.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Five study segments of the Self-Paced Physics Course materials are presented in this fourth problems and solutions book used as a part of student course work. The subject matter is related to electric charges, insulators, Coulomb's law, electric fields, lines of force, solid angles, conductors, motion of charged particles, dipoles, electric flux,…

  20. Inhibition of sarcoplasmic reticulum Ca(2+)-ATPase decreases atrioventricular node-paced heart rate in rabbits.

    Science.gov (United States)

    Cheng, Hongwei; Smith, Godfrey L; Orchard, Clive H; Hancox, Jules C; Burton, Francis L

    2012-10-01

    Recent data indicate that Ca(2+) cycling in isolated atrioventricular node (AVN) cells contributes to setting spontaneous rate. The aim of the present study was to extend this observation to the intact AVN in situ, by evaluating the effects of inhibiting sarcoplasmic reticulum Ca(2+) uptake with cyclopiazonic acid (CPA) on intact AVN spontaneous activity and its response to isoprenaline. A model of the AVN-paced heart was produced to investigate intact AVN automaticity, by surgical ablation of the sino-atrial node (SAN) in the rabbit Langendorff-perfused heart. Electrograms were recorded from a site close to the AVN (triangle of Koch), an atrial site above the AVN, the left atrium and right ventricle, enabling AVN pacing of the preparation to be confirmed. Before SAN ablation, the heart rate was 166.8 ± 5.4 beats min(-1). Ablation of the SAN was clearly indicated by a sudden and significant decrease of heart rate to 108.6 ± 9.6 beats min(-1) (P AVN rate to 187.8 ± 12.0 beats min(-1) after 1 min of application (P AVN rate to 81.6 ± 4.8 (n = 9) and 77.4 ± 6.0 beats min(-1) (n = 7), respectively [P AVN rate increase in response to isoprenaline from 78.8 ± 10.0 to 46.8 ± 6.8 and 26.7 ± 5.3%, respectively (P AVN rate and its response to isoprenaline indicate that Ca(2+) cycling is important to the intact AVN spontaneous activity and its acceleration during sympathetic stimulation.

  1. The effects of presentation pace and modality on learning a multimedia science lesson

    Science.gov (United States)

    Chung, Wen-Hung

    Working memory is a system that consists of multiple components. The visuospatial sketchpad is the main entrance for visual and spatial information, whereas acoustic and verbal information is processed in the phonological loop. The central executive works as a coordinator of information from these two subsystems. Numerous studies have shown that working memory has a very limited capacity. Based on these characteristics of working memory, theories such as cognitive load theory and the cognitive theory of multimedia learning provide multimedia design principles. One of these principles is that when verbal information accompanying pictures is presented in audio mode instead of visually, learning can be more effective than if both text and pictures are presented visually. This is called the modality effect. However, some studies have found that the modality effect does not occur in some situations. In most experiments examining the modality effect, the multimedia is presented as system-paced. If learners are able to repeat listening as many times as they need, the superiority of spoken text over visual text seems lessened. One aim of this study was to examine the modality effect in a learner-controlled condition. This study also used the one-word-at-a-time technique to investigate whether the modality effect would still occur if both reading and listening rates were equal. There were 182 college students recruited for this study. Participants were randomly assigned to seven groups: a self-paced listening group, a self-paced reading group, a self text-block reading group, a general-paced listening group, a general-paced reading group, a fast-paced listening group, and a fast-paced reading group. The experimental material was a cardiovascular multimedia module. A three-by-two between-subjects design was used to test the main effect. Results showed that modality effect was still present but not between the self-paced listening group and the self text-block reading group

  2. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    International Nuclear Information System (INIS)

    Wang Yu; Wang Yuxia; Chen Lei; Wan Qianhong

    2012-01-01

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 μg/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 μg/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high

  3. Pace of macrophage recruitment during different stages of soft tissue infection: Semi-quantitative evaluation by in vivo magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Seong; Sohn, Jin Young [University of Ulsan College of Medicine, Asan Medical Center, Laboratory for Molecular and Functional Imaging, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Jung, Hyun-Don; Kim, Sang-Tae [University of Ulsan College of Medicine, Asan Institute for Life Sciences, Seoul (Korea); Lee, Kyoung Geun [Korea University College of Life Sciences and Biotechnology, Division of Biotechnology, Seoul (Korea); Kang, Hee Jung [Hallym University College of Medicine, Department of Laboratory Medicine, Anyang (Korea)

    2008-10-15

    We describe the pace of recruitment of iron-oxide-labeled macrophages to the site of different stages of infection by in vivo magnetic resonance (MR) imaging. Peritoneal macrophages were labeled with superparamagnetic iron oxide ex vivo and administered through the tail vein 6 (acute) or 48 (subacute) h after bacterial inoculation. The legs of the mice were imaged sequentially on a 4.7-T MR unit before and 3, 6, 12, 18, 24, 48 and 72 h after macrophage administration. The band-shaped lower signal intensity zone around the abscess on T2*-weighted GRE images became more obvious due to recruited macrophages up until 24 h after injection in the subacute and 48 h after injection in the acute group, indicating that the relative SI of the abscess wall decreased more rapidly and the pace of recruitment of macrophages was faster in the subacute than in the acute group. Chemokine antibody arrays of mouse sera detected increased concentration of granulocyte-colony-stimulating factor and tissue inhibitor of metalloproteinase-1 beginning at 12 h and increased interleukin-13 at 18 h. Monocyte chemoattractant protein-1 and macrophage-colony-stimulating factor began to increase at 96 h after infection. This difference in pace of recruitment may result from the release of chemokines. (orig.)

  4. Pace of macrophage recruitment during different stages of soft tissue infection: Semi-quantitative evaluation by in vivo magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lee, Jin Seong; Sohn, Jin Young; Jung, Hyun-Don; Kim, Sang-Tae; Lee, Kyoung Geun; Kang, Hee Jung

    2008-01-01

    We describe the pace of recruitment of iron-oxide-labeled macrophages to the site of different stages of infection by in vivo magnetic resonance (MR) imaging. Peritoneal macrophages were labeled with superparamagnetic iron oxide ex vivo and administered through the tail vein 6 (acute) or 48 (subacute) h after bacterial inoculation. The legs of the mice were imaged sequentially on a 4.7-T MR unit before and 3, 6, 12, 18, 24, 48 and 72 h after macrophage administration. The band-shaped lower signal intensity zone around the abscess on T2*-weighted GRE images became more obvious due to recruited macrophages up until 24 h after injection in the subacute and 48 h after injection in the acute group, indicating that the relative SI of the abscess wall decreased more rapidly and the pace of recruitment of macrophages was faster in the subacute than in the acute group. Chemokine antibody arrays of mouse sera detected increased concentration of granulocyte-colony-stimulating factor and tissue inhibitor of metalloproteinase-1 beginning at 12 h and increased interleukin-13 at 18 h. Monocyte chemoattractant protein-1 and macrophage-colony-stimulating factor began to increase at 96 h after infection. This difference in pace of recruitment may result from the release of chemokines. (orig.)

  5. BezRindas.lv biļešu tirdzniecības Android lietotne

    OpenAIRE

    Upītis, Reinis

    2014-01-01

    Kvalifikācijas darbā tiek aprakstīta autobusu biļešu tirdzniecības lietotne, kas ir paredzēta viedtālruņiem ar Android operētājsistēmu. Mobilā lietotne paredzēta kā papildinājums jau esošam servisam – Bezrindas.lv. Aprakstītās sistēmas izveide atvieglotu biļešu iegādi lietotājiem, kas to vēlētos darīt ar saviem viedtālruņiem.

  6. Variables affecting the manifestation of and intensity of pacing behavior: A preliminary case study in zoo-housed polar bears.

    Science.gov (United States)

    Cless, Isabelle T; Lukas, Kristen E

    2017-09-01

    High-speed video analysis was used to quantify two aspects of gait in 10 zoo-housed polar bears. These two variables were then examined as to how they differed in the conditions of pacing versus locomoting for each bear. Percent difference calculations measured the difference between pacing and locomoting data for each bear. We inferred that the higher the percent difference between pacing and locomoting in a given subject, the more intense the pacing may be. The percent difference values were analyzed alongside caregiver survey data defining the locations, frequency, and anticipatory nature of pacing in each bear, as well as each bear's age and sex, to determine whether any variables were correlated. The frequency and intensity of pacing behavior were not correlated. However, location of pacing was significantly correlated both with the subjects' age and whether or not the subject was classified as an anticipatory pacer. Bears appeared to select specific spots within their exhibits to pace, and the location therefore seemed tied to underlying motivation for the behavior. Additionally, bears that were classified in the survey as pacing anticipatorily displayed significantly more intense pacing behavior as quantified by gait analysis. © 2017 Wiley Periodicals, Inc.

  7. Consumer responses to the Wisconsin Partnership Program for Elderly Persons: a variation on the PACE Model.

    Science.gov (United States)

    Kane, Robert L; Homyak, Patricia; Bershadsky, Boris; Lum, Yat-Sang

    2002-04-01

    The Wisconsin Partnership Program (WPP) is a variation on the Program for All-inclusive Care of the Elderly (PACE) model that is designed to be more flexible by allowing frail elderly dual-eligible (for both Medicare and Medicaid) clients to use their regular primary care physicians instead of relying on the physician hired by PACE. Case management is provided by a team of nurse, social worker, and nurse practitioner. The latter is charged with communicating with the client's primary physician. We compared the functional status and satisfaction of WPP elderly enrollees with those of two sets of dually eligible controls drawn from the Medicaid waiver rosters. One set of controls came from persons in the same county who opted not to enroll in WPP. The second came from matched counties that did not have access to the WPP. Enrollees were interviewed in person. Family members were interviewed by telephone. The prevalence of activities of daily living (ADLs) and instrumental activities of daily living (IADLs) dependency was lower for the WPP sample than that for the controls. The pattern of unmet needs was generally comparable. About half of each sample had a written advance directive. Overall, there were few areas of significant difference in beneficiaries' satisfaction. The WPP families were more satisfied than either control group that services were provided when needed and were better coordinated. There were no significant differences in the prevalence of any aspect of care burden. The impact of WPP seems limited. There is some evidence that families perceive better coordinated care. A more complete evaluation will await the analysis of the differences in utilization patterns between WPP and the controls.

  8. Optimizing classroom instruction through self-paced learning prototype

    Directory of Open Access Journals (Sweden)

    Romiro Gordo Bautista

    2015-09-01

    Full Text Available This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students’ learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was conducted, scored and analyzed which served as the basis in determining the initial learning schema of the respondents. A questionnaire was adopted to find the learning motivation of the students in science. Using Pearson-r correlation, it was found out that there is a highly significant relationship between their internal drive and their academic performance. Moreover, a post-test was conducted after self-paced learning prototype was used in the development of select topics in their curricular plot. It was found out that the students who experienced the self-paced learning prototype performed better in their academic performance as evidenced by the difference of their mean post-test results. ANCOVA results on the post-test mean scores of the respondents were utilized in establishing the causal-effect of the learning prototype to the academic performance of the students in Chemistry. A highly significant effect on their academic performance (R-square value of 70.7% and significant interaction of the models to the experimental grouping and mental abilities of the respondents are concluded in the study.

  9. Racing an Opponent Alters Pacing, Performance and Muscle Force Decline, But Not RPE

    NARCIS (Netherlands)

    Konings, Marco J; Parkinson, Jordan; Zijdewind, Inge; Hettinga, Florentina

    PURPOSE: Performing against a virtual opponent has been shown to invite a change in pacing and improve time trial (TT) performance. This study explored how this performance improvement is established by assessing changes in pacing, neuromuscular function and perceived exertion. METHODS: After a peak

  10. Even between-lap pacing despite high within-lap variation during mountain biking.

    Science.gov (United States)

    Martin, Louise; Lambeth-Mansell, Anneliese; Beretta-Azevedo, Liane; Holmes, Lucy A; Wright, Rachel; St Clair Gibson, Alan

    2012-09-01

    Given the paucity of research on pacing strategies during competitive events, this study examined changes in dynamic high-resolution performance parameters to analyze pacing profiles during a multiple-lap mountain-bike race over variable terrain. A global-positioning-system (GPS) unit (Garmin, Edge 305, USA) recorded velocity (m/s), distance (m), elevation (m), and heart rate at 1 Hz from 6 mountain-bike riders (mean±SD age=27.2±5.0 y, stature=176.8±8.1 cm, mass=76.3±11.7 kg, VO2max=55.1±6.0 mL·kg(-1)·min1) competing in a multilap race. Lap-by-lap (interlap) pacing was analyzed using a 1-way ANOVA for mean time and mean velocity. Velocity data were averaged every 100 m and plotted against race distance and elevation to observe the presence of intralap variation. There was no significant difference in lap times (P=.99) or lap velocity (P=.65) across the 5 laps. Within each lap, a high degree of oscillation in velocity was observed, which broadly reflected changes in terrain, but high-resolution data demonstrated additional nonmonotonic variation not related to terrain. Participants adopted an even pace strategy across the 5 laps despite rapid adjustments in velocity during each lap. While topographical and technical variations of the course accounted for some of the variability in velocity, the additional rapid adjustments in velocity may be associated with dynamic regulation of self-paced exercise.

  11. Biocorrosion of 316LV steel used in oral cavity due to Desulfotomaculum nigrificans bacteria.

    Science.gov (United States)

    Mystkowska, Joanna; Ferreira, Jose A; Leszczyńska, Katarzyna; Chmielewska, Sylwia; Dąbrowski, Jan Ryszard; Wieciński, Piotr; Kurzydłowski, Krzysztof Jan

    2017-01-01

    Corrosion processes of metallic biomaterials in the oral cavity pose a significant limitation to the life and reliable functioning of dental materials. In this article, the influence of environment bacteria Desulfotomaculum nigrificans sulfate reducing bacteria on the corrosion processes of 316LV steel was assessed. After 14 and 28 days of contact of the material with the bacterial environment, the surfaces of the tested biomaterial were observed by means of confocal scanning laser microscopy, and their chemical composition was studied using X-Ray Photoelectron Spectrometry and a scanning transmission electron microscopy. Corrosive changes, the presence of sulfur (with atomic concentration of 0.5%) on the surface of the biomaterial and the presence of a thin oxide layer (thickness of ∼20 nm) under the surface of the steel were observed. This corrosion layer with significant size reduction of grains was characterized by an increased amount of oxygen (18% mas., p < 0.001) in comparison to untreated 316LV steel (where oxygen concentration - 10% mas.). Image analysis conducted using APHELION software indicated that corrosion pits took up ∼2.8% of the total tested surface. The greatest number of corrosion pits had a surface area within the range of 100-200 μm 2 . © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 222-229, 2017. © 2015 Wiley Periodicals, Inc.

  12. Alterações clínicas e hematológicas em gatos domésticos naturalmente infectados pelo Vírus da Leucemia Felina (FeLV

    Directory of Open Access Journals (Sweden)

    Nádia Rossi de Almeida

    2016-07-01

    Full Text Available O Vírus da Leucemia Felina (FeLV é um retrovírus imunossupressor e o maior causador de morte dentre as doenças infecciosas felinas. O FeLV induz ao desenvolvimento de distúrbios degenerativos e/ou mieloproliferativos nos animais infectados, que sucumbem à infecções oportunistas devido à imunossupressão. As alterações nos parâmetros hematológicos em gatos FeLV positivos muitas vezes não condizem com o estado clínico do animal, podendo o mesmo ser um portador assintomático apresentando alterações hematológicas, ou sintomático sem alterações nestes parâmetros. O objetivo do presente estudo foi avaliar as alterações nos parâmetros clínicos e hematológicos de gatos domésticos infectados naturalmente pelo FeLV, nas fases sintomáticas e assintomáticas da doença. Desta forma, foram selecionados 40 gatos domiciliados previamente testados como positivos para o FeLV pela técnica de imunofluorescência indireta. O exame físico foi realizado e os animais foram separados em dois grupos: os gatos sintomáticos e os assintomáticos para a infecção. Amostras de sangue para a realização de hemograma foram coletadas de ambos os grupos e o teste estatístico ANOVA foi realizado para a comparação das alterações hematológicas. O exame clínico indicou 37,5% dos gatos como portadores assintomáticos e 62,5% sintomáticos, sendo a perda de peso e alterações de mucosas os achados mais frequentes. O hemograma evidenciou anemia e linfopenia como os parâmetros hematológicos que apresentaram diferenças estatísticas entre os dois grupos estudados, sendo que 56% dos gatos assintomáticos apresentaram anemia. Em face aos resultados encontrados, concluiu-se que gatos FeLV positivos sintomáticos apresentaram alterações hematológicas condizentes com o quadro de imunossupressão clínico.

  13. A Closer Look at Split Visual Attention in System- and Self-Paced Instruction in Multimedia Learning

    Science.gov (United States)

    Schmidt-Weigand, Florian; Kohnert, Alfred; Glowalla, Ulrich

    2010-01-01

    Two experiments examined visual attention distribution in learning from text and pictures. Participants watched a 16-step multimedia instruction on the formation of lightning. In Experiment 1 (N=90) the instruction was system-paced (fast, medium, slow pace), while it was self-paced in Experiment 2 (N=31). In both experiments the text modality was…

  14. Infants' Visual Attention to Baby DVDs as a Function of Program Pacing

    Science.gov (United States)

    Gola, Alice Ann Howard; Calvert, Sandra L.

    2011-01-01

    This study examined the effects of program pacing, defined as the rate of scene and character change per minute, on infants' visual attention to video presentations. Seventy-two infants (twenty-four 6-month-olds, twenty-four 9-month-olds, twenty-four 12-month-olds) were exposed to one of two sets of high- and low-paced commercial infant DVDs. Each…

  15. PACES: A Model of Student Well-Being

    Science.gov (United States)

    Nelson, Mark D.; Tarabochia, Dawn W.; Koltz, Rebecca L.

    2015-01-01

    School counselors design, deliver, and evaluate comprehensive, developmental school counseling programs that are focused on enhancing student development and success. A model of student well-being, known as PACES, is defined and described that consists of five distinct and interactive domains: physical, affective, cognitive, economic, and social.…

  16. Extending the use of the pacing pulmonary artery catheter for safe minimally invasive cardiac surgery.

    Science.gov (United States)

    Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G

    2010-08-01

    In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.

  17. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking

    Science.gov (United States)

    Buhmann, Jeska; Desmet, Frank; Moens, Bart; Van Dyck, Edith; Leman, Marc

    2016-01-01

    The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended) synchronization. But is this velocity effect still present with non-instructed (spontaneous) synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities. PMID:27167064

  18. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking.

    Science.gov (United States)

    Buhmann, Jeska; Desmet, Frank; Moens, Bart; Van Dyck, Edith; Leman, Marc

    2016-01-01

    The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended) synchronization. But is this velocity effect still present with non-instructed (spontaneous) synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities.

  19. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking.

    Directory of Open Access Journals (Sweden)

    Jeska Buhmann

    Full Text Available The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended synchronization. But is this velocity effect still present with non-instructed (spontaneous synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities.

  20. Metabolic Responses and Pacing Strategies during Successive Sprint Skiing Time Trials

    DEFF Research Database (Denmark)

    Andersson, Erik; Holmberg, Hans-Christer; Ørtenblad, Niels

    2016-01-01

    PURPOSE: To examine the metabolic responses and pacing strategies during the performance of successive sprint time trials (STTs) in cross-country skiing. METHODS: Ten well-trained male cross-country skiers performed four self-paced 1300-m STTs on a treadmill, each separated by 45 min of recovery...... to estimate the anaerobic energy supply. RESULTS: The individual trial-to-trial variability in STT performance time was 1.3%, where variations in O2 deficit and V˙O2 explained 69% (P 0.05) of the variation in performance. The first and last STTs were equally fast (228 ± 10 s), and ~ 1...... on the first than second course half. In addition, metabolic rates were substantially higher (~_30%) for uphill than for flat skiing, indicating that pacing was regulated to the terrain. CONCLUSIONS: The fastest STTs were characterized primarily by a greater anaerobic energy production, which also explained 69...

  1. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    Science.gov (United States)

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  2. Impact of Distributed Generation Grid Code Requirements on Islanding Detection in LV Networks

    Directory of Open Access Journals (Sweden)

    Fabio Bignucolo

    2017-01-01

    Full Text Available The recent growing diffusion of dispersed generation in low voltage (LV distribution networks is entailing new rules to make local generators participate in network stability. Consequently, national and international grid codes, which define the connection rules for stability and safety of electrical power systems, have been updated requiring distributed generators and electrical storage systems to supply stabilizing contributions. In this scenario, specific attention to the uncontrolled islanding issue has to be addressed since currently required anti-islanding protection systems, based on relays locally measuring voltage and frequency, could no longer be suitable. In this paper, the effects on the interface protection performance of different LV generators’ stabilizing functions are analysed. The study takes into account existing requirements, such as the generators’ active power regulation (according to the measured frequency and reactive power regulation (depending on the local measured voltage. In addition, the paper focuses on other stabilizing features under discussion, derived from the medium voltage (MV distribution network grid codes or proposed in the literature, such as fast voltage support (FVS and inertia emulation. Stabilizing functions have been reproduced in the DIgSILENT PowerFactory 2016 software environment, making use of its native programming language. Later, they are tested both alone and together, aiming to obtain a comprehensive analysis on their impact on the anti-islanding protection effectiveness. Through dynamic simulations in several network scenarios the paper demonstrates the detrimental impact that such stabilizing regulations may have on loss-of-main protection effectiveness, leading to an increased risk of unintentional islanding.

  3. Value of the New Spline QTc Formula in Adjusting for Pacing-Induced Changes in Heart Rate

    Directory of Open Access Journals (Sweden)

    Hirmand Nouraei

    2018-01-01

    Full Text Available Aims. To determine whether a new QTc calculation based on a Spline fit model derived and validated from a large population remained stable in the same individual across a range of heart rates (HRs. Second, to determine whether this formula incorporating QRS duration can be of value in QT measurement, compared to direct measurement of the JT interval, during ventricular pacing. Methods. Individuals (N=30; 14 males aged 51.9 ± 14.3 years were paced with decremental atrial followed by decremental ventricular pacing. Results. The new QTc changed minimally with shorter RR intervals, poorly fit even a linear relationship, and did not fit a second-order polynomial. In contrast, the Bazett formula (QTcBZT showed a steep and marked increase in QTc with shorter RR intervals. For atrial pacing data, QTcBZT was fit best by a second-order polynomial and demonstrated a dramatic increase in QTc with progressively shorter RR intervals. For ventricular pacing, the new QTc minus QRS duration did not meaningfully change with HR in contrast to the HR dependency of QTcBZT and JT interval. Conclusion. The new QT correction formula is minimally impacted by HR acceleration induced by atrial or ventricular pacing. The Spline QTc minus QRS duration is an excellent method to estimate QTc in ventricular paced complexes.

  4. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  5. Dual-anticipating, dual and dual-lag synchronization in modulated time-delayed systems

    International Nuclear Information System (INIS)

    Ghosh, Dibakar; Chowdhury, A. Roy

    2010-01-01

    In this Letter, dual synchronization in modulated time delay system using delay feedback controller is proposed. Based on Lyapunov stability theory, we suggest a general method to achieve the dual-anticipating, dual, dual-lag synchronization of time-delayed chaotic systems and we find both its existing and sufficient stability conditions. Numerically it is shown that the dual synchronization is also possible when driving system contain two completely different systems. Effect of parameter mismatch on dual synchronization is also discussed. As an example, numerical simulations for the Mackey-Glass and Ikeda systems are conducted, which is in good agreement with the theoretical analysis.

  6. The effect of aging on pacing strategies of cross-country skiers and the role of performance level.

    Science.gov (United States)

    Nikolaidis, Pantelis Theodoros; Villiger, Elias; Rosemann, Thomas; Knechtle, Beat

    2018-01-01

    The participation of master cross-country (XC) skiers in training and competition has increased during the last decades; however, little is known yet about whether these athletes differ from their younger counterparts in aspects of performance such as pacing. Therefore, the aim of the present study was to examine the combined effect of age and performance (race time) on pacing in cross-country (XC) skiing. We analyzed all finishers ( n  = 79,722) in 'Vasaloppet' from 2012 to 2017, the largest cross-country skiing race in the world, classified according to their race time into 10 groups: 3-4 h, 4-5 h, ..., 12-13 h. A trivial main effect of sex on total pace range was observed ( p  < 0.001, η 2  = 0.002), where women (44.1 ± 10.2%) had larger total pace range than men (40.9 ± 11.8%). A large main effect of performance group on total pace range was shown ( p  < 0.001, η 2  = 0.160), where the smallest total pace range was 21.8 ± 1.9% (3-4 h group) and the largest 50.1 ± 9.9% (10-11 h group). A trivial sex×performance group interaction on total pace range was found ( p  < 0.001, η 2  = 0.001) with the largest sex difference in pacing shown in 9-10 h group. A trivial and small main effect of age was found in women ( p  < 0.001, η 2  = 0.005) and men ( p  < 0.001, η 2  = 0.011), respectively, where the masters had smaller total pace range than their younger counterparts. A trivial age group×performance group interaction on total pace range was observed in both women ( p  < 0.001, η 2  = 0.008) and men ( p  < 0.001, η 2  = 0.006) with smaller differences among age groups in the faster performance groups. In summary, master XC skiers adopted a relatively even pacing independently from their race time and the differences in pacing from the younger XC skiers were more pronounced in the slower masters. These findings suggest that exercise attenuates the decline of performance in

  7. Three-dimensional binding sites volume assessment during cardiac pacing lead extraction

    Directory of Open Access Journals (Sweden)

    Bich Lien Nguyen

    2015-07-01

    Conclusions: Real-time 3D binding sites assessment is feasible and improves transvenous lead extraction outcomes. Its role as a complementary information requires extensive validation, and might be beneficial for a tailored strategy.

  8. Activation of the Prefrontal Cortex While Performing a Task at Preferred Slow Pace and Metronome Slow Pace: A Functional Near-Infrared Spectroscopy Study

    Directory of Open Access Journals (Sweden)

    Kaori Shimoda

    2014-01-01

    Full Text Available Individuals have a preferred pace at which they perform voluntary repetitive movements. Previous studies have reported that greater activation of the prefrontal cortex was observed during self-initiated movements than during externally triggered movements. The purpose of the present study is to compare the activation of the prefrontal cortex induced when the subjects performed a peg-board task at their preferred slow pace (PSP, the self-initiated condition with that induced when they performed the same task at metronome slow pace (MSP, the externally triggered condition using functional near-infrared spectroscopy. Healthy subjects performed the task while sitting in a chair. By assessing the activated channels individually, we confirmed that all of the prefrontal regions of interest were activated by both tasks. In the second-level analyses, we found that the activation detected in the frontopolar cortex (FPPFC; Brodmann area 10 was higher during the PSP task than during the MSP task. The FPPFC is known to be at the top of prefrontal hierarchy, and specifically involved in evaluating self-generated information. In addition, the FPPFC plays a role in coordinating lateral prefrontal cortex. In the present study, the subjects evaluated and managed the internally generated PSP by coordinating the activity of other lower level prefrontal regions.

  9. Activation of the prefrontal cortex while performing a task at preferred slow pace and metronome slow pace: a functional near-infrared spectroscopy study.

    Science.gov (United States)

    Shimoda, Kaori; Moriguchi, Yoshiya; Tsuchiya, Kenji; Katsuyama, Shiori; Tozato, Fusae

    2014-01-01

    Individuals have a preferred pace at which they perform voluntary repetitive movements. Previous studies have reported that greater activation of the prefrontal cortex was observed during self-initiated movements than during externally triggered movements. The purpose of the present study is to compare the activation of the prefrontal cortex induced when the subjects performed a peg-board task at their preferred slow pace (PSP, the self-initiated condition) with that induced when they performed the same task at metronome slow pace (MSP, the externally triggered condition) using functional near-infrared spectroscopy. Healthy subjects performed the task while sitting in a chair. By assessing the activated channels individually, we confirmed that all of the prefrontal regions of interest were activated by both tasks. In the second-level analyses, we found that the activation detected in the frontopolar cortex (FPPFC; Brodmann area 10) was higher during the PSP task than during the MSP task. The FPPFC is known to be at the top of prefrontal hierarchy, and specifically involved in evaluating self-generated information. In addition, the FPPFC plays a role in coordinating lateral prefrontal cortex. In the present study, the subjects evaluated and managed the internally generated PSP by coordinating the activity of other lower level prefrontal regions.

  10. A new intracavitary probe for detecting the site of origin of ectopic ventricular beats during one cardiac cycle.

    Science.gov (United States)

    Taccardi, B; Arisi, G; Macchi, E; Baruffi, S; Spaggiari, S

    1987-01-01

    An olive-shaped probe (25 X 12 mm) with 41 evenly distributed recording electrodes on its surface was introduced into the left ventricles of seven open-chest dogs via the left atrium. In two other dogs a cylindrical probe (40 X 3 mm) was used. Electrical stimuli were delivered at 66 endocardial, midwall, or epicardial sites in the left and right ventricular walls and the septum. Mechanical stimuli were also applied at various epicardial sites. On-line mapping of equipotential contour lines on the surface of the probe invariably revealed a clear-cut potential minimum on the electrode that faced the pacing site. Time of appearance of potential minimum was 3 to 5 msec after endocardial stimuli, 10 to 25 msec for midwall and epicardial pacing, and 30 msec or more for right ventricular stimulation. Simultaneous stimulation at two sites 1.2 cm apart gave rise to two separate minima on the maps. "Pseudoisochrones" derived from electrograms recorded by the new probe were slightly less accurate in indicating the site of origin of extrasystoles. We conclude that equipotential and "isochrone" contour maps recorded from an array of semidirect electrodes, regularly distributed on the surface of an intraventricular probe, provide information on the site of origin (location and intramural depth) of ectopic paced beats in a normal dog heart.

  11. Social Interaction in Self-paced Distance Education

    Directory of Open Access Journals (Sweden)

    Terry Anderson

    2015-02-01

    Full Text Available In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions with other students and to share as little or as much personal information with each other as they wished. We describe the learning design for the intervention and present survey data of student and tutor perception of value and content analysis of the archived contributions. The results indicate that the intervention was positively received by tutors and by the majority (but not all students and that the archive created by the students’ contributions was adding value to the course. We conclude that the intervention was a modest, yet manageable example of a learning enhancement to a traditional cognitive-behavioral, course that has positive impact and potential with little negative impact on workload.

  12. Pacing the US magnetic fusion program

    International Nuclear Information System (INIS)

    1989-01-01

    This study addresses the priority and pace of the nation's magnetic fusion research and development program in the context of long-term national energy policy. In particular, the committee interpreted its task as follows: To review the implications of long-term national energy policy for current research and development in magnetic fusion; to identify factors that should enter the further development of such policy to reduce risks associated with the future electricity supply system; to propose criteria applicable to research and develop in electric generation in reaching long-term energy policy goals; to apply these criteria to magnetic fusion and alternative electric generation technologies in order to develop recommendations on the priority pace of the magnetic fusion program; and to present its results in a final report. The most important goals of the US Department of Energy's current Magnetic Fusion Energy Program Plan are to demonstrate the scientific and engineering feasibility of fusion, Demonstrating engineering feasibility will require the design, construction, and operation of an engineering test reactor, which the plan envisions financing through a combination of domestic and international funding. The committee believes that current domestic program funding levels are inadequate to meet even the near-term objectives of the plan

  13. Dual Entwining Structures and Dual Entwined Modules

    OpenAIRE

    Abuhlail, Jawad Y.

    2003-01-01

    In this note we introduce and investigate the concepts of dual entwining structures and dual entwined modules. This generalizes the concepts of dual Doi-Koppinen structures and dual Doi-Koppinen modules introduced (in the infinite case over rings) by the author is his dissertation.

  14. The Role of Dual Tasking in the Assessment of Gait, Cognition and Community Reintegration of Veterans with Mild Traumatic Brain Injury.

    Science.gov (United States)

    Leland, Azadeh; Tavakol, Kamran; Scholten, Joel; Mathis, Debra; Maron, David; Bakhshi, Simin

    2017-12-01

    This study focussed on the effect of dual versus single tasking on balance, gait and cognition in veterans with mild traumatic brain injury (mTBI). We examined the correlation between these parameters, with responses to questions on community reintegration activities. 22 male and female veterans (aged 19-65) walked along a narrow and 6.1-meter long path, both at their self-selected and fastest but safe pace under single and dual tasking conditions. For dual tasking, participants were required to recall and vocalize a 5-digit number at the end of the path. The outcome measures were the accuracy, velocity, cadence, stride length, and number of steps off the path. We calculated the reliability and correlation coefficient values for the walking time compared with the stride length, velocity, and percentage of swing and stance. Under dual task, the participants demonstrated slower gait, recalled shorter digit span and stepped off the path 12.6% more often than under single task. The stride length decreased by about 20% and the stride velocity increased by over 2% in dual compared with single tasking. Dual tasking slows down the gait and reduces the attention span in patients with mTBI, which can negatively impact their community reintegration, at least early after their hospital discharge, hence the need for exercising caution with their community reintegration activities. Dual tasking may have the potential to improve balance, gait and attention span of the patients in the long-term, thus leading to safer community integration, if incorporated in the rehabilitation plans.

  15. A fast-start pacing strategy speeds pulmonary oxygen uptake kinetics and improves supramaximal running performance.

    Directory of Open Access Journals (Sweden)

    Tiago Turnes

    Full Text Available The focus of the present study was to investigate the effects of a fast-start pacing strategy on running performance and pulmonary oxygen uptake (VO2 kinetics at the upper boundary of the severe-intensity domain. Eleven active male participants (28±10 years, 70±5 kg, 176±6 cm, 57±4 mL/kg/min visited the laboratory for a series of tests that were performed until exhaustion: 1 an incremental test; 2 three laboratory test sessions performed at 95, 100 and 110% of the maximal aerobic speed; 3 two to four constant speed tests for the determination of the highest constant speed (HS that still allowed achieving maximal oxygen uptake; and 4 an exercise based on the HS using a higher initial speed followed by a subsequent decrease. To predict equalized performance values for the constant pace, the relationship between time and distance/speed through log-log modelling was used. When a fast-start was utilized, subjects were able to cover a greater distance in a performance of similar duration in comparison with a constant-pace performance (constant pace: 670 m±22%; fast-start: 683 m±22%; P = 0.029; subjects also demonstrated a higher exercise tolerance at a similar average speed when compared with constant-pace performance (constant pace: 114 s±30%; fast-start: 125 s±26%; P = 0.037. Moreover, the mean VO2 response time was reduced after a fast start (constant pace: 22.2 s±28%; fast-start: 19.3 s±29%; P = 0.025. In conclusion, middle-distance running performances with a duration of 2-3 min are improved and VO2 response time is faster when a fast-start is adopted.

  16. RIght VErsus Left Apical transvenous pacing for bradycardia: Results of the RIVELA randomized study

    Directory of Open Access Journals (Sweden)

    Haran Burri

    2017-11-01

    Full Text Available Aims: To compare cardiac function when pacing from the right or left ventricular apex in patients with preserved left ventricular systolic function, at 1-year follow-up. Methods: Prospective, multicentre centre randomizing conventional right ventricular apical (RVA versus left ventricular apical (LVA pacing using a coronary sinus lead in patients requiring ventricular pacing for bradycardia. Follow-up was performed using 3D-echocardiography at 6 and 12 months. Results: A total of 36 patients (age 75.4 ± 8.7 years, 21 males were enrolled (17 patients in the RVA group and 19 patients in the LVA group. A right ventricular lead was implanted in 8 patients in the LVA group, mainly because of high capture thresholds. There were no differences in the primary endpoint of LVEF at 1 year (60.4 ± 7.1% vs 62.1 ± 7.2% for the RVA and LVA groups respectively, P = 0.26 nor in any of the secondary endpoints (left ventricular dimensions, left ventricular diastolic function, right ventricular systolic function and tricuspid/mitral insufficiency. LVEF did not change significantly over follow-up in either group. Capture thresholds were significantly higher in the LVA group, and two patients had unexpected loss of capture of the coronary sinus lead during follow-up. Conclusions: Left univentricular pacing seems to be comparable to conventional RVA pacing in terms of ventricular function at up to 1 year follow-up, and is an option to consider in selected patients (e.g. those with a tricuspid valve prosthesis. Keywords: Ventricular pacing, Right ventricle, Left ventricle, Coronary sinus, Ventricular function

  17. Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.

    Science.gov (United States)

    O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E

    2018-04-26

    Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.

  18. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  19. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  20. Measurement and monitoring technologies are important SITE program component

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    An ongoing component of the Superfund Innovative Technologies Evaluation (SITE) Program, managed by the US EPA at its Hazardous Waste Engineering Research Laboratory in Cincinnati, is the development and demonstration of new and innovative measurement and monitoring technologies that will be applicable to Superfund site characterization. There are four important roles for monitoring and measurement technologies at Superfund sites: (1) to assess the extent of contamination at a site, (2) to supply data and information to determine impacts to human health and the environment, (3) to supply data to select the appropriate remedial action, and (4) to monitor the success or effectiveness of the selected remedy. The Environmental Monitoring Systems Laboratory in Las Vegas, Nevada (EMSL-LV) has been supporting the development of improved measurement and monitoring techniques in conjunction with the SITE Program with a focus on two areas: Immunoassay for toxic substances and fiber optic sensing for in-situ analysis at Superfund sites

  1. Project of Ariane 5 LV family advancement by use of reusable fly-back boosters (named “Bargouzine”)

    Science.gov (United States)

    Sumin, Yu.; Bonnal, Ch.; Kostromin, S.; Panichkin, N.

    2007-12-01

    The paper concerns possible concept variants of a partially reusable Heavy-Lift Launch Vehicle derived from the advanced basic launcher (Ariane-2010) by means of substitution of the EAP Solid Rocket Boosters for a Reusable Starting Stage consisting two Liquid-propellant Reusable Fly-Back Boosters called "Bargouzin". This paper describes the status of the presently studied RFBB concepts during its three phases. The first project phase was dedicated to feasibility expertise of liquid-rocket reusable fly-back boosters ("Baikal" type) utilization for heavy-lift space launch vehicle. The design features and main conclusions are presented. The second phase has been performed with the purpose of selection of preferable concept among the alternative ones for the future Ariane LV modernization by using RFBB instead of EAP Boosters. The main requirements, logic of work, possible configuration and conclusion are presented. Initial aerodynamic, ballistic, thermoloading, dynamic loading, trade-off and comparison analysis have been performed on these concepts. The third phase consists in performing a more detailed expertise of the chosen LV concept. This part summarizes some of the more detailed results related to flight performance, system mass, thermoprotection system, aspects of technologies, ground complex modification, comparison analyses and conclusion.

  2. Vocal cord collapse during phrenic nerve-paced respiration in congenital central hypoventilation syndrome.

    Science.gov (United States)

    Domanski, Mark C; Preciado, Diego A

    2012-01-01

    Phrenic nerve pacing can be used to treat congenital central hypoventilation syndrome (CCHS). We report how the lack of normal vocal cord tone during phrenic paced respiration can result in passive vocal cord collapse and produce obstructive symptoms. We describe a case of passive vocal cord collapse during phrenic nerve paced respiration in a patient with CCHS. As far as we know, this is the first report of this etiology of airway obstruction. The patient, a 7-year-old with CCHS and normal waking vocal cord movement, continued to require nightly continuous positive airway pressure (CPAP) despite successful utilization of phrenic nerve pacers. On direct laryngoscopy, the patient's larynx was observed while the diaphragmatic pacers were sequentially engaged. No abnormal vocal cord stimulation was witnessed during engaging of either phrenic nerve stimulator. However, the lack of normal inspiratory vocal cord abduction during phrenic nerve-paced respiration resulted in vocal cord collapse and partial obstruction due to passive adduction of the vocal cords through the Bernoulli effect. Bilateral phrenic nerve stimulation resulted in more vocal cord collapse than unilateral stimulation. The lack of vocal cord abduction on inspiration presents a limit to phrenic nerve pacers.

  3. Fluorescence and Magnetic Resonance Dual-Modality Imaging-Guided Photothermal and Photodynamic Dual-Therapy with Magnetic Porphyrin-Metal Organic Framework Nanocomposites

    Science.gov (United States)

    Zhang, Hui; Li, Yu-Hao; Chen, Yang; Wang, Man-Man; Wang, Xue-Sheng; Yin, Xue-Bo

    2017-03-01

    Phototherapy shows some unique advantages in clinical application, such as remote controllability, improved selectivity, and low bio-toxicity, than chemotherapy. In order to improve the safety and therapeutic efficacy, imaging-guided therapy seems particularly important because it integrates visible information to speculate the distribution and metabolism of the probe. Here we prepare biocompatible core-shell nanocomposites for dual-modality imaging-guided photothermal and photodynamic dual-therapy by the in situ growth of porphyrin-metal organic framework (PMOF) on Fe3O4@C core. Fe3O4@C core was used as T2-weighted magnetic resonance (MR) imaging and photothermal therapy (PTT) agent. The optical properties of porphyrin were well remained in PMOF, and PMOF was therefore selected for photodynamic therapy (PDT) and fluorescence imaging. Fluorescence and MR dual-modality imaging-guided PTT and PDT dual-therapy was confirmed with tumour-bearing mice as model. The high tumour accumulation of Fe3O4@C@PMOF and controllable light excitation at the tumour site achieved efficient cancer therapy, but low toxicity was observed to the normal tissues. The results demonstrated that Fe3O4@C@PMOF was a promising dual-imaging guided PTT and PDT dual-therapy platform for tumour diagnosis and treatment with low cytotoxicity and negligible in vivo toxicity.

  4. Towards PACE Atmospheric Correction, Aerosol and Cloud Products: Making Use of Expanded Spectral, Angular and Polarimetric Information.

    Science.gov (United States)

    Remer, L. A.; Boss, E.; Ahmad, Z.; Cairns, B.; Chowdhary, J.; Coddington, O.; Davis, A. B.; Dierssen, H. M.; Diner, D. J.; Franz, B. A.; Frouin, R.; Gao, B. C.; Garay, M. J.; Heidinger, A.; Ibrahim, A.; Kalashnikova, O. V.; Knobelspiesse, K. D.; Levy, R. C.; Omar, A. H.; Meyer, K.; Platnick, S. E.; Seidel, F. C.; van Diedenhoven, B.; Werdell, J.; Xu, F.; Zhai, P.; Zhang, Z.

    2017-12-01

    NASA's Science Team for the Plankton, Aerosol, Clouds, ocean Ecosystem (PACE) mission is concluding three years of study exploring the science potential of expanded spectral, angular and polarization capability for space-based retrievals of water leaving radiance, aerosols and clouds. The work anticipates future development of retrievals to be applied to the PACE Ocean Color Instrument (OCI) and/or possibly a PACE Multi-Angle Polarimeter (MAP). In this presentation we will report on the Science Team's accomplishments associated with the atmosphere (significant efforts are also directed by the ST towards the ocean). Included in the presentation will be sensitivity studies that explore new OCI capabilities for aerosol and cloud layer height, aerosol absorption characterization, cloud property retrievals, and how we intend to move from heritage atmospheric correction algorithms to make use of and adjust to OCI's hyperspectral and UV wavelengths. We will then address how capabilities will improve with the PACE MAP, how these capabilities from both OCI and MAP correspond to specific societal benefits from the PACE mission, and what is still needed to close the gaps in our understanding before the PACE mission can realize its full potential.

  5. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    Science.gov (United States)

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  6. Toxoplasma gondii, Dirofilaria immitis, feline immunodeficiency virus (FIV), and feline leukemia virus (FeLV) infections in stray and pet cats (Felis catus) in northwest China: co-infections and risk factors.

    Science.gov (United States)

    Cong, Wei; Meng, Qing-Feng; Blaga, Radu; Villena, Isabelle; Zhu, Xing-Quan; Qian, Ai-Dong

    2016-01-01

    This study was conducted to estimate the prevalence of Toxoplasma gondii, Dirofilaria immitis, feline immunodeficiency virus (FIV), and feline leukemia virus (FeLV) infections among stray and pet cats in Lanzhou, northwest China, and to identify the influence of age, gender, and regions on seropositivity. T. gondii antibodies were examined in cat sera by the modified agglutination test (MAT). The circulating antigens of D. immitis and FeLV and specific antibodies to FIV were examined using kits commercially available. The overall prevalence of T. gondii, FIV, FeLV, and D. immitis was 19.34, 9.12, 11.33, and 3.04 %, respectively. For the genetic characterization of T. gondii genotypes in cats, genomic DNA was extracted from the seropositive cats and the T. gondii B1 gene was amplified using a semi-nested PCR. DNA samples giving positive B1 amplification were then genotyped using multilocus PCR-RFLP. Two T. gondii genotypes (ToxoDB#9 and ToxoDB#1) were identified. Results of the multivariate logistic regression analysis showed that older cats are more likely to be seropositive than juveniles for T. gondii, FIV, FeLV, and D. immitis. This is the first report of T. gondii genotypes in cats in northwest China. Moreover, the present study is the first study of retrovirus and D. immitis seroprevalence in cats in China. The results revealed that T. gondii, FIV, and FeLV infections are common in stray and pet cats in northwest China.

  7. Effect of the Pacing Strategies on the Open Water 10km World Swimming Championships Performances.

    Science.gov (United States)

    Rodriguez, Luis; Veiga, Santiago

    2017-10-16

    The aim of the present research was 1) to compare the pacing strategies of different level open water swimmers during the 10km race of the FINA 2015 World Swimming Championships (WCH), and 2) to relate these pacing strategies to the race performance. Final and intermediate split times as well as intermediate race positions from the 10-kilometer race participants (69 men and 51 women) were collected from the public domain and were divided into five groups (G1 to G5) depending on their finishing positions. Medalists and finalists (G1 and G2, respectively) presented an even pacing profile with similar swimming velocities to the less successful swimmers (G3 to G5) on the initial and mid stages of the race but a 1.5-3% increase in swimming velocity in the last quarter of the race. This fast end spurt was largely related to the race performance and was not observed in the G3 and G4 (even-paced profile) or in the G5 (positive pacing profile) groups. Intermediate race positions and lap rankings were negatively related to finishing position indicating a delayed positioning of the most successful swimmers at 25%, 50% and 75% of race distance. The adoption of a conservative starting strategy by open water swimmers with a negative pacing profile and delayed partial positioning seems to increase the chances of overall race success as it allows a fast end spurt that is highly related to successful finishing race positions.

  8. MCTS self-paced training kit (exam 70-680) configuring Windows 7

    CERN Document Server

    McLean, Ian

    2010-01-01

    NOTE: The most recent printings of this title incorporate corrections to errors found in the earlier printings. This Self-Paced Training Kit is designed to help maximize your performance on 70-680, the required exam for the Microsoft® Certified Technology Specialist (MCTS): Windows 7, Configuration certification.This 2-in-1 kit includes the official Microsoft study guide, plus practice tests on CD to help you assess your skills. It comes packed with the tools and features exam candidates want most-including in-depth, self-paced training based on final exam content; rigorous, objective-by-obj

  9. International piping benchmarks: use of the simplified code PACE 2. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J T; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom); ed.

    1979-05-15

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost.

  10. Earlier Right Ventricular Pacing in Cardiac Resynchronization Therapy for a Patient with Right Axis Deviation.

    Science.gov (United States)

    Hattori, Yusuke; Ishibashi, Kohei; Noda, Takashi; Okamura, Hideo; Kanzaki, Hideaki; Anzai, Toshihisa; Yasuda, Satoshi; Kusano, Kengo

    2017-09-01

    We describe the case of a 37-year-old woman who presented with complete right bundle branch block and right axis deviation. She was admitted to our hospital due to severe heart failure and was dependent on inotropic agents. Cardiac resynchronization therapy was initiated but did not improve her condition. After the optimization of the pacing timing, we performed earlier right ventricular pacing, which led to an improvement of her heart failure. Earlier right ventricular pacing should be considered in patients with complete right bundle branch block and right axis deviation when cardiac resynchronization therapy is not effective.

  11. Specification of requirements to get a license for an Independent Spent Fuel Dry Storage Installation (ISFSI) at the site of the NPP-LV; Especificacion de los requerimientos para tramitar una licencia de una instalacion independiente de almacenamiento temporal en seco de combustible gastado (ISFSI) en el sitio de la CNLV

    Energy Technology Data Exchange (ETDEWEB)

    Serrano R, M. L., E-mail: mlserrano@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    This article describes some of the work done in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) to define specifically the requirements that the Federal Electricity Commission (CFE) shall meet to submit for consideration of CNSNS an operation request of an Independent Spent Fuel Dry Storage Installation (ISFSI). The project of a facility of this type arose from the need to provide storage capacity for spent nuclear fuel in the nuclear power plant of Laguna Verde (NPP-LV) and to continue the operation at the same facility in a safe manner. The licensing of these facilities in the United States of America has two modes: specific license or general license. The characteristics of these licenses are described in this article. However, in Mexico the existing national legislation is not designed for such license types, in fact there is a lack of standards or regulations in this regard. The regulatory law of Article 27 of the Constitution in the nuclear matter, only generally establishes that this type of facility requires an authorization from the Ministry of Energy. For this reason and because there is not a national legislation, was necessary to use the legislation that provides the Nuclear Regulatory Commission of USA, the US NRC. However, it cannot be applied as is established, so was necessary that the CNSNS analyze one by one the requirements of both types of license and determine what would be required to NPP-LV to submit its operating license of ISFSI. The American regulatory applicable to an ISFSI, the 10-Cfr-72 of the US NRC, establishes the requirements for both types of licenses. Chapter 10-Cfr was analyzed in all its clauses and coupled to the laws, regulations and standards as well as to the requirements established by CNSNS, all associated with a store spent fuel on site; the respective certification of containers for spent fuel dry storage was not included in this article, even though the CNSNS also performed that activity under the

  12. Future of dual-use space awareness technologies

    Science.gov (United States)

    Kislitsyn, Boris V.; Idell, Paul S.; Crawford, Linda L.

    2000-10-01

    The use of all classes of space systems, whether owned by defense, civil, commercial, scientific, allied or foreign organizations, is increasing rapidly. In turn, the surveillance of such systems and activities in space are of interest to all parties. Interests will only increase in time and with the new ways to exploit the space environment. However, the current space awareness infrastructure and capabilities are not maintaining pace with the demands and advanced technologies being brought online. The use of surveillance technologies, some of which will be discussed in the conference, will provide us the eventual capability to observe and assess the environment, satellite health and status, and the uses of assets on orbit. This provides us a space awareness that is critical to the military operator and to the commercial entrepreneur for their respective successes. Thus the term 'dual-use technologies' has become a reality. For this reason we will briefly examine the background, current, and future technology trends that can lead us to some insights for future products and services.

  13. High Voltage Gain Dual Active Bridge Converter with an Extended Operation Range for Renewable Energy Systems

    DEFF Research Database (Denmark)

    Zhang, Zhe; Tomas Manez, Kevin; Yudi, Xiao

    2018-01-01

    Bridge (P2DAB) converter, i.e. low-voltage (LV) side parallel and high-voltage (HV) side series, is proposed to achieve high voltage gain and low current stress over switching devices and transformer windings. Given the unmodified P2DAB power stage, by regulating the phase-shift angle between......Developing bidirectional dc-dc converters has become a critical research topic and gains more and more attention in recent years due to the extensive applications of smart grids with energy storages, hybrid and electrical vehicles and dc microgrids. In this paper, a Partial Parallel Dual Active...... the paralleled active bridges, the power equations and voltage gain are then modified, and therefore the operation range can be extended effectively. The operating principles of the proposed converter and its power characteristics under various operation modes are studied, and the design constraints...

  14. An appropriate compression pace is important for securing the quality of hands-only CPR--a manikin study.

    Science.gov (United States)

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-09-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-second break between the sets. The percentage of compressions deeper than 5 cm at pace-110-g decreased significantly from 22.1 ± 4.7% in the first set to 16.7 ± 4.4%* in the second set (*p CPR.

  15. Dual Binding Site and Selective Acetylcholinesterase Inhibitors Derived from Integrated Pharmacophore Models and Sequential Virtual Screening

    Directory of Open Access Journals (Sweden)

    Shikhar Gupta

    2014-01-01

    Full Text Available In this study, we have employed in silico methodology combining double pharmacophore based screening, molecular docking, and ADME/T filtering to identify dual binding site acetylcholinesterase inhibitors that can preferentially inhibit acetylcholinesterase and simultaneously inhibit the butyrylcholinesterase also but in the lesser extent than acetylcholinesterase. 3D-pharmacophore models of AChE and BuChE enzyme inhibitors have been developed from xanthostigmine derivatives through HypoGen and validated using test set, Fischer’s randomization technique. The best acetylcholinesterase and butyrylcholinesterase inhibitors pharmacophore hypotheses Hypo1_A and Hypo1_B, with high correlation coefficient of 0.96 and 0.94, respectively, were used as 3D query for screening the Zinc database. The screened hits were then subjected to the ADME/T and molecular docking study to prioritise the compounds. Finally, 18 compounds were identified as potential leads against AChE enzyme, showing good predicted activities and promising ADME/T properties.

  16. Synchronous intra-myocardial ventricular pacing without crossing the tricuspid valve or entering the coronary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Konecny, Tomas; DeSimone, Christopher V.; Friedman, Paul A.; Bruce, Charles [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Asirvatham, Samuel J., E-mail: asirvatham.samuel@mayo.edu [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Department of Pediatric and Adolescent Medicine, Pediatric Cardiology, Mayo Clinic, Rochester, MN (United States)

    2013-05-15

    Ventricular pacing is most commonly performed at the right ventricular (RV) apex. This is not without risk as placement requires crossing the tricuspid valve (TV) and may cause valvular dysfunction and dyssynchronous activation of the ventricles. The fact that the tricuspid valve lies more apically than the mitral valve allows for the possibility of pacing the ventricles from the right atrium (RA) via the “atrio-ventricular septum” without crossing the TV or entering the coronary sinus (CS). In order to mitigate far field activation inherent to current pacing technology, we constructed a novel lead in which the cathode and anode are both intra-myocardial. We demonstrate safety and efficacy of this novel lead for ventricular pacing at the atrio-ventricular septum in canines, including improved synchronous activation of both ventricles, improved differentiation in ventricular versus atrial sensing, while providing reliable ventricular capture, opening novel and a potentially safer alternative to human cardiac resynchronization therapy.

  17. Atrial pacing as an alternative to supine exercise (SE) in radionuclide ventriculography (RNV)

    International Nuclear Information System (INIS)

    Le Grand, V.; Wells, S.; O'Neil, W.W.; Jenkins, J.; Gross, M.D.; Vogel, R.

    1984-01-01

    Stress RNV is at times of limited value as many patients cannot achieve a sufficient pressure rate product (PRP). Atrial pacing is a noninvasive alternative to SE by bicycle ergometry. A swallowable electrode attached to a flexible wire is positioned in a retroatrial position in the esophagus and when connected to a variable output stimulator, variable rate (120, 140, 160 beats/min) atrial pacing ventriculography (APV) can be performed. RNV is performed in the sitting position at rest and at each pacing stage. APV was compared to SE RNV in 4 patients with coronary artery disease (CAD) and 3 normal volunteers (N). Tolerance to APV was excellent with adequate pacing. All subjects reported a minor sensation of chest burning. No arrhythmias occurred. At maximal APV mean PRP was 174 +- 26. The diastolic volumes in APV fell in all patients. Systolic volumes fell in N but not in CAD to APV. A flat EF response to APV was seen in both N and CAD patients. APV is an alternative to SE RNV although PRP remains low. Volume changes in APV are different than in SE RNV and in the interpretation of the results of APV in CAD, changes in systolic and diastolic volumes may be more important than the response of EF

  18. Person-Centered Care for Older Adults With Serious Mental Illness and Substance Misuse Within a Program of All-Inclusive Care for the Elderly.

    Science.gov (United States)

    Cacchione, Pamela Z; Eible, Lisa; Gill, Le'Roi L; Huege, Steven F

    2016-05-01

    Providing person-centered care (PCC) to older adults with dual diagnosis, co-occurring serious mental illness (SMI), and substance misuse is complex and requires an interprofessional team. Older adults, who qualify for both Medicaid and Medicare (i.e., dual-eligibles) are overrepresented in the population of older adults with SMI and substance misuse. Programs of All-Inclusive Care for the Elderly (PACE) exist to support community living needs of nursing home-eligible older adults and are increasingly in a position to serve older adults with SMI and substance misuse issues. PACE programs provide integrated person-centered mental health care to address the serious medical, social, and emotional complications posed by having SMI and substance misuse disorders. The case study presented illustrates PCC provided to a dual-diagnosis PACE participant, illustrating the impact of recent and past trauma on current psychopathology and substance misuse. Finally, recommendations for addressing PCC of dual diagnosis within the PACE model are provided. [Journal of Gerontological Nursing, 42(5), 11-17.]. Copyright 2016, SLACK Incorporated.

  19. Keeping Pace with K-12 Online Learning, 2016

    Science.gov (United States)

    Gemin, Butch; Pape, Larry

    2017-01-01

    "Keeping Pace with K-12 Online Learning 2016" marks the thirteenth consecutive year Evergreen has published its annual research of the K-12 education online learning market. The thirteen years of researching, writing and publishing this report represents a time of remarkable change. There has been a constant presence that has become the…

  20. Optimizing Classroom Instruction through Self-Paced Learning Prototype

    Science.gov (United States)

    Bautista, Romiro G.

    2015-01-01

    This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students' learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was…

  1. The pace of vocabulary growth helps predict later vocabulary skill

    Science.gov (United States)

    Rowe, Meredith L.; Raudenbush, Stephen W.; Goldin-Meadow, Susan

    2011-01-01

    Children vary widely in the rate at which they acquire words—some start slow and speed up, others start fast and continue at a steady pace. Do early developmental variations of this sort help predict vocabulary skill just prior to kindergarten entry? This longitudinal study starts by examining important predictors (SES, parent input, child gesture) of vocabulary growth between 14 and 46 months (n=62), and then uses growth estimates to predict children's vocabulary at 54 months. Velocity and acceleration in vocabulary development at 30 months predicted later vocabulary, particularly for children from low socioeconomic backgrounds. Understanding the pace of early vocabulary growth thus improves our ability to predict school readiness, and may help identify children at risk for starting behind. PMID:22235920

  2. An Investigation on Exhaustion of SAP ERP Users: Influence of Pace of Change and Technostress

    Directory of Open Access Journals (Sweden)

    Prashanta Kumar Roy

    2017-10-01

    Full Text Available Despite recent growing research interest on ERP research, the understanding on ERP induced exhaustion is still limited. This study examines how the pace of change of ERP functionalities and interface causes exhaustion in workplace. For this purpose, we conducted an investigation on 128 ERP users from two different organizations in Bangladesh. We extended theory of technostress by integrating pace of change of ERP system. Result suggests that pace of change on ERP system significantly affect work-overload, work-life conflict and role ambiguity on ERP users. Result also shows that work-overload and role ambiguity are strong predictors for ERP induced exhaustion.

  3. Levodopa reinstates connectivity from prefrontal to premotor cortex during externally paced movement in Parkinson's disease

    DEFF Research Database (Denmark)

    Herz, Damian M; Siebner, Hartwig R; Hulme, Oliver J

    2014-01-01

    , which were externally paced at a rate of 0.5Hz. This required participants to align their movement velocity to the slow external pace. Patients were studied after at least 12-hour withdrawal of dopaminergic medication (OFF state) and after intake of the dopamine precursor levodopa (ON state) in order...

  4. Challenge of Engaging All Students via Self-Paced Interactive Electronic Learning Tutorials for Introductory Physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-01-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar…

  5. Child and Parental Outcomes Following Involvement in a Preventive Intervention: Efficacy of the PACE Program

    Science.gov (United States)

    Begle, Angela Moreland; Dumas, Jean E.

    2011-01-01

    This study evaluated whether engagement (i.e., attendance and quality of participation) in the Parenting our Children to Excellence (PACE) program predicted positive child and parent outcomes. PACE in an 8-week preventive intervention aimed at parents of preschool children. The study investigated the relation of engagement to outcomes in an…

  6. Rationale and design of the BUDAPEST-CRT Upgrade Study: a prospective, randomized, multicentre clinical trial.

    Science.gov (United States)

    Merkely, Bela; Kosztin, Annamaria; Roka, Attila; Geller, Laszlo; Zima, Endre; Kovacs, Attila; Boros, Andras Mihaly; Klein, Helmut; Wranicz, Jerzy K; Hindricks, Gerhard; Clemens, Marcell; Duray, Gabor Z; Moss, Arthur J; Goldenberg, Ilan; Kutyifa, Valentina

    2017-09-01

    There is lack of conclusive evidence from randomized clinical trials on the efficacy and safety of upgrade to cardiac resynchronization therapy (CRT) in patients with implanted pacemakers (PM) or defibrillators (ICD) with reduced left ventricular ejection fraction (LVEF) and chronic heart failure (HF). The BUDAPEST-CRT Upgrade Study was designed to compare the efficacy and safety of CRT upgrade from conventional PM or ICD therapy in patients with intermittent or permanent right ventricular (RV) septal/apical pacing, reduced LVEF, and symptomatic HF. The BUDAPEST-CRT study is a prospective, randomized, multicentre, investigator-sponsored clinical trial. A total of 360 subjects will be enrolled with LVEF ≤ 35%, NYHA functional classes II-IVa, paced QRS ≥ 150 ms, and a RV pacing ≥ 20%. Patients will be followed for 12 months. Randomization is performed in a 3:2 ratio (CRT-D vs. ICD). The primary composite endpoint is all-cause mortality, a first HF event, or less than 15% reduction in left ventricular (LV) end-systolic volume at 12 months. Secondary endpoints are all-cause mortality, all-cause mortality or HF event, and LV volume reduction at 12 months. Tertiary endpoints include changes in quality of life, NYHA functional class, 6 min walk test, natriuretic peptides, and safety outcomes. The results of our prospective, randomized, multicentre clinical trial will provide important information on the role of cardiac resynchronization therapy with defibrillator (CRT-D) upgrade in patients with symptomatic HF, reduced LVEF, and wide-paced QRS with intermittent or permanent RV pacing. NCT02270840. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  7. A Scenario-Based Approach for Energy Storage Capacity Determination in LV Grids with High PV Penetration

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Yang, Guangya

    2014-01-01

    In this paper a new method is proposed to determine the minimum energy storage required to be installed at different locations of a low voltage (LV) grid in order to prevent the overvoltage due to high residential photovoltaic (PV) penetration. The method is based on the voltage sensitivity...... with different occurrence probabilities without involving the time-series studies problems. The proposed method is capable of modeling output power of PV panels with different orientations as well as different electric vehicle (EV) charging patterns....

  8. Laboratorios virtuales (LV como apoyo a las prácticas a distancia y presenciales en ingeniería

    Directory of Open Access Journals (Sweden)

    Francis Castellanos

    2010-01-01

    Full Text Available El presente artículo tiene como propósito mostrar los procesos inherentes a cada una de las etapas de diseño y desarrollo en un Laboratorio Virtual, LV, y más específicamente para el laboratorio redes convergentes de la Institución. Durante la investigación, se desarrolló una metodología basada en los lineamientos del PMI (Project Management Institute que servirá como base para la creación de futuros laboratorios virtuales en cualquier área del conocimiento. Para el acceso de los laboratorios se desarrolló la herramienta de Software Vlab, como una plataforma integradora de laboratorios virtuales para la Institución. Los LV son simulaciones consideradas como una alternativa pedagógica para el desarrollo de prácticas a distancia o como apoyo a las prácticas en la presencialidad, que ofrecen a los estudiantes la oportunidad de adquirir destrezas y habilidades en el manejo de materiales y equipos relacionados con las áreas de su campo de formación, sin restricción de tiempo o espacio.

  9. An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR : A manikin study

    OpenAIRE

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-01-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-secon...

  10. PACE: A dynamic programming algorithm for hardware/software partitioning

    DEFF Research Database (Denmark)

    Knudsen, Peter Voigt; Madsen, Jan

    1996-01-01

    This paper presents the PACE partitioning algorithm which is used in the LYCOS co-synthesis system for partitioning control/dataflow graphs into hardware and software parts. The algorithm is a dynamic programming algorithm which solves both the problem of minimizing system execution time...

  11. Successful pacing using a batteryless sunlight-powered pacemaker.

    Science.gov (United States)

    Haeberlin, Andreas; Zurbuchen, Adrian; Schaerer, Jakob; Wagner, Joerg; Walpen, Sébastien; Huber, Christoph; Haeberlin, Heinrich; Fuhrer, Juerg; Vogel, Rolf

    2014-10-01

    Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  12. MFTF-B PACE tests and final cost report

    International Nuclear Information System (INIS)

    Krause, K.H.; Kozman, T.A.; Smith, J.L.; Horan, R.J.

    1986-10-01

    The Mirror Fusion Test Facility (MFTF-B) construction project was successfully completed in February 1986, with the conclusion of the Plant and Capital Equipment (PACE) Tests. This series of tests, starting in September 1985 and running through February 1986, demonstrated the overall machine capabilities and special facilities accomplishments for the Mirror Fusion Test Facility Project

  13. Selectively enhanced expression of prophenoloxidase activating enzyme 1 (PPAE1 at a bacteria clearance site in the white shrimp, Litopenaeus vannamei

    Directory of Open Access Journals (Sweden)

    Jang In-Kwon

    2011-12-01

    Full Text Available Abstract Background The prophenoloxidase-activating (PO activating system plays an important role in the crustacean innate immunity, particularly in wound healing and pathogen defense. A key member of this system is prophenoloxidase-activating enzyme (PPAE, which is the direct activator of prophenoloxidase (proPO. Despite their importance in crustacean PO activating system, the studies on them remain limited. Results Here we report on a PPAE of white shrimp, Litopenaeus vannamei (lvPPAE1, which showed 94% similarity to PPAE1 of Penaeus monodon. We found that lvPPAE1 in fluid hemocytes was down regulated after challenge by Vibrio harveyi but was enhanced when shrimps were exposed to a bacteria-rich environment for long-term. In vivo gene silence of lvPPAE1 by RNAi can significantly reduce the phenoloxidase activity (PO and increase the susceptibility of shrimps to V. harveyi. Although lvPPAE1 was down-regulated in fluid hemocytes by Vibrio challenge, its expression increased significantly in gill after bacteria injection, which is the primary bacteria-clearance tissue. Conclusion Suppressed expression in fluid hemocytes and enhanced expression in gill indicates selectively enhanced expression at the bacterial clearance site. This is a novel feature for PPAE expression. The results will contribute to our understanding of the PO activating system in crustaceans.

  14. MRI with cardiac pacing devices – Safety in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko, E-mail: touko.kaasalainen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Physics, University of Helsinki (Finland); Pakarinen, Sami, E-mail: sami.pakarinen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Kivistö, Sari, E-mail: sari.kivisto@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Holmström, Miia, E-mail: miia.holmstrom@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Hänninen, Helena, E-mail: helena.hanninen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Peltonen, Juha, E-mail: juha.peltonen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki (Finland); Lauerma, Kirsi, E-mail: kirsi.lauerma@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Sipilä, Outi, E-mail: outi.sipila@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland)

    2014-08-15

    Objectives: The aim of this study was to introduce a single centre “real life” experience of performing MRI examinations in clinical practice on patients with cardiac pacemaker systems. Additionally, we aimed to evaluate the safety of using a dedicated safety protocol for these patients. Materials and methods: We used a 1.5 T MRI scanner to conduct 68 MRI scans of different body regions in patients with pacing systems. Of the cardiac devices, 32% were MR-conditional, whereas the remaining 68% were MR-unsafe. We recorded the functional parameters of the devices prior, immediately after, and approximately one month after the MRI scanning, and compared the device parameters to the baseline values. Results: All MRI examinations were completed safely, and each device could be interrogated normally following the MRI. We observed no changes in the programmed parameters of the devices. For most of the participants, the distributions of the immediate and one-month changes in the device parameters were within 20% of the baseline values, although some changes approached clinically important thresholds. Furthermore, we observed no differences in the variable changes between MR-conditional and MR-unsafe pacing systems, or between scans of the thorax area and other scanned areas. Conclusion: MRI in patients with MR-conditional pacing systems and selected MR-unsafe systems could be performed safely under strict conditions in this study.

  15. Dual-energy radiographic absorptiometry of the lumbar spine and proximal femur

    International Nuclear Information System (INIS)

    Moscona, A.; Gundry, C.; Sartoris, D.J.; Barrett-Connor, E.; Stein, J.A.; Resnick, D.

    1988-01-01

    Dual-energy radiographic absorptiometry (DRA), dual-photon absorptiometry (DPA), and single-photon absorptiometry (SPA) were used for comprehensive densitometry of 500 men and women aged 65-100 years, within an epidemiologic study of osteoporosis risk factors. DRA and DPA of the lumbar spine (L1-L4) and proximal femur were performed with a Hologic QDR-100 system and a Lunar DP3 system, respectively, and SPA of the 33% shaft and ultradistal forearm sites was performed with a Lunar SP2 system. DRA and DPA results showed high correlation at both sites (tau=.9,P<.001); data conversion factors were derived. SPA results for the ultradistal site correlated better with vertebral and femoral density (tau=.6,P<.1) than did those for the shaft site (tau=.4,P<.5) but neither forearm measurement was reliable predictive of axial mineral status. The various measurements displayed an age-dependent interrelationship. The DRA method offers the advantage of short examination times (about 5 minutes per site) and high precision (about 1%)

  16. Atrial pacing and thallium 201 scintigraphy: combined use for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Stratmann, H.G.; Mark, A.L.; Walter, K.E.; Fletcher, J.W.; Williams, G.A.

    1987-01-01

    To evaluate the presence of coronary artery disease (CAD), atrial pacing and thallium 201 scintigraphy were performed in 36 patients with stable angina pectoris who were unable to perform an adequate exercise stress test. All patients underwent cardiac catheterization. Nine patients had previously undergone coronary artery bypass surgery. Significant CAD (one or more lesions greater than or equal to 50%) was present in 33 patients. Atrial pacing produced ischemic ST segment depression (greater than or equal to 1 mm) in 18 (55%) patients with CAD, and angina in 20 patients (61%). As the number of vessels with CAD increased, there was no significant change in the sensitivities of pacing-induced angina or ST segment depression for detecting CAD. In the 3 patients without CAD, ST segment depression occurred in 1 patient and angina in none. Thallium 201 scintigraphy demonstrated perfusion defects in 27 (82%) patients with CAD, with fixed defects seen in 13 studies (39%) and reversible defects in 15 (45%). In the 3 patients without CAD, no perfusion defects were seen. The thallium 201 scan successfully predicted the presence of CAD in patients with single-vessel disease but usually underestimated the number of vessels involved in patients with multivessel disease. Combined sensitivity of pacing-induced ST segment depression and an abnormal thallium 201 scan finding for detecting CAD was 91%. The authors conclude that combined atrial pacing and thallium 201 scintigraphy is a useful test for detecting CAD in patients unable to perform an adequate exercise stress test

  17. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    International Nuclear Information System (INIS)

    Karlstrom, L.; Kelly, K.A.

    1989-01-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction

  18. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    Energy Technology Data Exchange (ETDEWEB)

    Karlstrom, L.; Kelly, K.A. (Mayo Clinic, Rochester, MN (USA))

    1989-11-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction.

  19. Symptoms of chronic fatigue syndrome/myalgic encephalopathy are not determined by activity pacing when measured by the chronic pain coping inventory.

    Science.gov (United States)

    Thompson, D P; Antcliff, D; Woby, S R

    2018-03-01

    Chronic fatigue syndrome/myalgic encephalopathy (CFS/ME) is a chronic illness which can cause significant fatigue, pain and disability. Activity pacing is frequently advocated as a beneficial coping strategy, however, it is unclear whether pacing is significantly associated with symptoms in people with CFS/ME. The first aim of this study was therefore to explore the cross-sectional associations between pacing and levels of pain, disability and fatigue. The second aim was to explore whether changes in activity pacing following participation in a symptom management programme were related to changes in clinical outcomes. Cross-sectional study exploring the relationships between pacing, pain, disability and fatigue (n=114) and pre-post treatment longitudinal study of a cohort of patients participating in a symptom management programme (n=35). Out-patient physiotherapy CFS/ME service. One-hundred and fourteen adult patients with CFS/ME. Pacing was assessed using the chronic pain coping inventory. Pain was measured using a Numeric Pain Rating Scale, fatigue with the Chalder Fatigue Scale and disability with the Fibromyalgia Impact Questionnaire. No significant associations were observed between activity pacing and levels of pain, disability or fatigue. Likewise, changes in pacing were not significantly associated with changes in pain, disability or fatigue following treatment. Activity pacing does not appear to be a significant determinant of pain, fatigue or disability in people with CFS/ME when measured with the chronic pain coping index. Consequently, the utility and measurement of pacing require further investigation. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  20. Some properties of dual and approximate dual of fusion frames

    OpenAIRE

    Arefijamaal, Ali Akbar; Neyshaburi, Fahimeh Arabyani

    2016-01-01

    In this paper we extend the notion of approximate dual to fusion frames and present some approaches to obtain dual and approximate alternate dual fusion frames. Also, we study the stability of dual and approximate alternate dual fusion frames.

  1. Statistical decision making with a dual-detector probe

    International Nuclear Information System (INIS)

    Hickernell, T.S.

    1988-01-01

    Conventional imaging techniques for cancer detection have difficulty finding small, deep tumors. Single-detector radiation probes have been developed to search for deep lesions in a patient who has been given a tumor-seeking radiopharmaceutical. These probes perform poorly, however, when the background activity in the patient varies greatly from site to site. We have developed a surgical dual-detector probe that solves the problem of background activity variation, by simultaneously monitoring counts from a region of interest and counts from adjacent normal tissue. A comparison of counts from the detectors can reveal the class of tissue, tumor or normal, in the region of interest. In this study, we apply methods from statistical decision theory and derive a suitable comparison of counts to help us decide whether a tumor is present in the region of interest. We use the Hotelling trace criterion with a few assumptions to find a linear discriminant function, which can be reduced to a normalized subtraction of the counts for large background count-rate variations. Using a spatial response map of the dual probe, a computer torso phantom, and estimates of activity distribution, we simulate a surgical staging procedure to test the dual probe and the discriminant functions

  2. Challenge of Helping Introductory Physics Students Transfer Their Learning by Engaging with a Self-Paced Learning Tutorial

    Directory of Open Access Journals (Sweden)

    Emily Megan Marshman

    2018-03-01

    Full Text Available With advances in digital technology, research-validated self-paced learning tools can play an increasingly important role in helping students with diverse backgrounds become good problem solvers and independent learners. Thus, it is important to ensure that all students engage with self-paced learning tools effectively in order to learn the content deeply, develop good problem-solving skills, and transfer their learning from one context to another. Here, we first provide an overview of a holistic framework for engaging students with self-paced learning tools so that they can transfer their learning to solve novel problems. The framework not only takes into account the features of the self-paced learning tools but also how those tools are implemented, the extent to which the tools take into account student characteristics, and whether factors related to students’ social environments are accounted for appropriately in the implementation of those tools. We then describe an investigation in which we interpret the findings using the framework. In this study, a research-validated self-paced physics tutorial was implemented in both controlled one-on-one interviews and in large enrollment, introductory calculus-based physics courses as a self-paced learning tool. We find that students who used the tutorial in a controlled one-on-one interview situation performed significantly better on transfer problems than those who used it as a self-paced learning tool in the large-scale implementation. The findings suggest that critically examining and taking into account how the self-paced tools are implemented and incentivized, student characteristics including their self-regulation and time-management skills, and social and environmental factors can greatly impact the extent and manner in which students engage with these learning tools. Getting buy in from students about the value of these tools and providing appropriate support while implementing them is

  3. The Applicability of Rhythm-Motor Tasks to a New Dual Task Paradigm for Older Adults

    Directory of Open Access Journals (Sweden)

    Soo Ji Kim

    2017-12-01

    Full Text Available Given the interplay between cognitive and motor functions during walking, cognitive demands required during gait have been investigated with regard to dual task performance. Along with the needs to understand how the type of concurrent task while walking affects gait performance, there are calls for diversified dual tasks that can be applied to older adults with varying levels of cognitive decline. Therefore, this study aimed to examine how rhythm-motor tasks affect dual task performance and gait control, compared to a traditional cognitive-motor task. Also, it examined whether rhythm-motor tasks are correlated with traditional cognitive-motor task performance and cognitive measures. Eighteen older adults without cognitive impairment participated in this study. Each participant was instructed to walk at self-paced tempo without performing a concurrent task (single walking task and walk while separately performing two types of concurrent tasks: rhythm-motor and cognitive-motor tasks. Rhythm-motor tasks included instrument playing (WalkIP, matching to rhythmic cueing (WalkRC, and instrument playing while matching to rhythmic cueing (WalkIP+RC. The cognitive-motor task involved counting forward by 3s (WalkCount.f3. In each condition, dual task costs (DTC, a measure for how dual tasks affect gait parameters, were measured in terms of walking speed and stride length. The ratio of stride length to walking speed, a measure for dynamic control of gait, was also examined. The results of this study demonstrated that the task type was found to significantly influence these measures. Rhythm-motor tasks were found to interfere with gait parameters to a lesser extent than the cognitive-motor task (WalkCount.f3. In terms of ratio measures, stride length remained at a similar level, walking speed greatly decreased in the WalkCount.f3 condition. Significant correlations between dual task-related measures during rhythm-motor and cognitive-motor tasks support the

  4. Deviation from goal pace, body temperature and body mass loss as predictors of road race performance.

    Science.gov (United States)

    Adams, William M; Hosokawa, Yuri; Belval, Luke N; Huggins, Robert A; Stearns, Rebecca L; Casa, Douglas J

    2017-03-01

    The purpose of this study was to examine the relationship between pacing, gastrointestinal temperature (T GI ), and percent body mass loss (%BML) on relative race performance during a warm weather 11.3km road race. Observational study of a sample of active runners competing in the 2014 Falmouth Road Race. Participants ingested a T GI pill and donned a GPS enabled watch with heart rate monitoring capabilities prior to the start of the race. Percent off predicted pace (% OFF ) was calculated for seven segments of the race. Separate linear regression analyses were used to assess the relationship between pace, T ​GI , and %BML on relative race performance. One-way ANOVA was used to analyse post race T GI (≥40°C vs 0.05). There was a trend in a slower pace (p=0.055) and greater % OFF (p=0.056) in runners finishing the race with a T GI >40°C. Overall, finish time was influenced by greater variations in pace during the first two miles of the race. In addition, runners who minimized fluid losses and had lower T GI were associated with meeting self-predicted goals. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Percutaneous removal of a pacing electrode

    International Nuclear Information System (INIS)

    Hoehne, U.; Schild, H.; Hake, U.

    1989-01-01

    The large number of pace-makers introduced transvenously has resulted in increasing the number of complications, amongst which infections and dislocations are prominent. It is usually necessary to remove the electrode, which can be attempted percutaneously by using a Dormia basket, a loop or forceps. Amongst the complications of this procedure are tears to the myocardium, with the risk of pericardial tamponade, or tears of the tricuspid valve leading to tricuspid insufficiency. Consequently, thoracic surgical intervention should be available if necessary. Four successful procedures are described. (orig.) [de

  6. Time perception, pacing and exercise intensity: maximal exercise distorts the perception of time

    OpenAIRE

    Edwards, A. M.; McCormick, A.

    2017-01-01

    Introduction\\ud \\ud Currently there are no data examining the impact of exercise on the perception of time, which is surprising as optimal competitive performance is dependent on accurate pacing using knowledge of time elapsed.\\ud \\ud \\ud Methods\\ud \\ud With institutional ethics approval, 12 recreationally active adult participants (f = 7, m = 5) undertook both 30 s Wingate cycles and 20 min (1200 s) rowing ergometer bouts as short and long duration self-paced exercise trials, in each of thre...

  7. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    Science.gov (United States)

    Wang, Yu; Wang, Yuxia; Chen, Lei; Wan, Qian-Hong

    2012-02-01

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 μg/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 μg/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high

  8. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  9. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Borleffs, C.J.W.; Schalij, Martin J.; Wall, Ernst E. van der; Bax, Jeroen J.; Dibbets-Schneider, Petra; Hiel, Bernies van der; Younis, Imad Al

    2011-01-01

    The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of ≥15% in LVESV. Enrolled in the study were 90 patients (72% men, 67±10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements. (orig.)

  10. Failure of communication and capture: The perils of temporary unipolar pacing system.

    Science.gov (United States)

    Sahinoglu, Efe; Wool, Thomas J; Wool, Kenneth J

    2015-06-01

    We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  11. Noninvasive estimation of global activation sequence using the extended Kalman filter.

    Science.gov (United States)

    Liu, Chenguang; He, Bin

    2011-03-01

    A new algorithm for 3-D imaging of the activation sequence from noninvasive body surface potentials is proposed. After formulating the nonlinear relationship between the 3-D activation sequence and the body surface recordings during activation, the extended Kalman filter (EKF) is utilized to estimate the activation sequence in a recursive way. The state vector containing the activation sequence is optimized during iteration by updating the error variance/covariance matrix. A new regularization scheme is incorporated into the "predict" procedure of EKF to tackle the ill-posedness of the inverse problem. The EKF-based algorithm shows good performance in simulation under single-site pacing. Between the estimated activation sequences and true values, the average correlation coefficient (CC) is 0.95, and the relative error (RE) is 0.13. The average localization error (LE) when localizing the pacing site is 3.0 mm. Good results are also obtained under dual-site pacing (CC = 0.93, RE = 0.16, and LE = 4.3 mm). Furthermore, the algorithm shows robustness to noise. The present promising results demonstrate that the proposed EKF-based inverse approach can noninvasively estimate the 3-D activation sequence with good accuracy and the new algorithm shows good features due to the application of EKF.

  12. Hybrid lentivirus-phiC31-int-NLS vector allows site-specific recombination in murine and human cells but induces DNA damage.

    Directory of Open Access Journals (Sweden)

    Nicolas Grandchamp

    Full Text Available Gene transfer allows transient or permanent genetic modifications of cells for experimental or therapeutic purposes. Gene delivery by HIV-derived lentiviral vector (LV is highly effective but the risk of insertional mutagenesis is important and the random/uncontrollable integration of the DNA vector can deregulate the cell transcriptional activity. Non Integrative Lentiviral Vectors (NILVs solve this issue in non-dividing cells, but they do not allow long term expression in dividing cells. In this context, obtaining stable expression while avoiding the problems inherent to unpredictable DNA vector integration requires the ability to control the integration site. One possibility is to use the integrase of phage phiC31 (phiC31-int which catalyzes efficient site-specific recombination between the attP site in the phage genome and the chromosomal attB site of its Streptomyces host. Previous studies showed that phiC31-int is active in many eukaryotic cells, such as murine or human cells, and directs the integration of a DNA substrate into pseudo attP sites (pattP which are homologous to the native attP site. In this study, we combined the efficiency of NILV for gene delivery and the specificity of phiC31-int for DNA substrate integration to engineer a hybrid tool for gene transfer with the aim of allowing long term expression in dividing and non-dividing cells preventing genotoxicity. We demonstrated the feasibility to target NILV integration in human and murine pattP sites with a dual NILV vectors system: one which delivers phiC31-int, the other which constitute the substrate containing an attB site in its DNA sequence. These promising results are however alleviated by the occurrence of significant DNA damages. Further improvements are thus required to prevent chromosomal rearrangements for a therapeutic use of the system. However, its use as a tool for experimental applications such as transgenesis is already applicable.

  13. Low settings of the ventricular pacing output in patients dependent on a pacemaker: are they really safe?

    Science.gov (United States)

    Schuchert, Andreas; Frese, Jens; Stammwitz, Ekkehard; Novák, Miroslav; Schleich, Arthur; Wagner, Stefan M; Meinertz, Thomas

    2002-06-01

    It is generally acknowledged that pacemaker output must be adjusted with a 100% voltage safety margin above the pacing threshold to avoid ineffective pacing, especially in patients dependent on pacemakers. The aim of this prospective crossover study was to assess the beat-to-beat safety of low outputs in patients who are dependent on a pacemaker between 2 follow-up examinations. The study included 12 patients who had received a DDD pacemaker with an automatic beat-to-beat capture verification function. The ventricular output at 0.4 milliseconds pulse duration was programmed independently of the actual pacing threshold in a crossover randomization to 1.0 V, 1.5 V, and 2.5 V for 6 weeks each. At each follow-up, the diagnostic counters were interrogated and the pacing threshold at 0.4 milliseconds was determined in 0.1-V steps. The diagnostic pacemaker counters depict the frequency of back-up pulses delivered because of a loss of capture. During the randomization to 1.0-V output, we evaluated whether the adjustment of the output under consideration of the >100% voltage safety margin reduced the frequency of back-up pulses. Pacing thresholds at the randomization to 1.0-V, 1.5-V, and 2.5-V output were not significantly different, with 0.7 +/- 0.3 V at 2.5-V output, 0.6 +/- 0.2 V at 1.5-V output, and 0.6 +/- 0.2 V at 1.0-V output. The frequency of back-up pulses was similar at 2.5-V and 1.5-V output, 2.2% +/- 1.9% and 2.0% +/- 2.0%, respectively. The frequency of back-up pulses significantly increased at 1.0-V output to 5.8% +/- 6.4% (P 5% of the time between the 2 follow-ups were observed in no patient at 2.5 V, in 1 patient at 1.5 V, and in 5 patients at 1.0 V. At the randomization to the 1.0-V output, 6 patients had pacing thresholds of 0.5 V or less, and 6 patients had pacing thresholds >0.5 V. The frequency of back-up pulses in the 2 groups was not significantly different, 6.4% +/- 8.6% and 5.7% +/- 2.6%. The frequency of back-up pulses was significantly higher at 1

  14. Effects of Benzalkonium Chloride, Proxel LV, P3 Hypochloran, Triton X-100 and DOWFAX 63N10 on anaerobic digestion processes

    DEFF Research Database (Denmark)

    Flores, German Antonio Enriquez; Fotidis, Ioannis; Karakashev, Dimitar Borisov

    2015-01-01

    In this study, the individual and synergistic toxicity of the following xenobiotics: Benzalkonium Chloride (BKC), Proxel LV (PRX), P3 Hypochloran (HPC), Triton X-100 (TRX), and DOWFAX 63N10 (DWF), on anaerobic digestion (AD) process, was assessed. The experiments were performed in batch and conti......In this study, the individual and synergistic toxicity of the following xenobiotics: Benzalkonium Chloride (BKC), Proxel LV (PRX), P3 Hypochloran (HPC), Triton X-100 (TRX), and DOWFAX 63N10 (DWF), on anaerobic digestion (AD) process, was assessed. The experiments were performed in batch...... and continuous (up-flow anaerobic sludge blanket, UASB) reactors with biochemical-industrial wastewater, as substrate. In batch experiments, half-maximal inhibitory concentrations (IC50) for the tested xenobiotics were found to be 13.1, 1003, 311.5 and 24.3 mg L1 for BKC, PRX, DWF and TRX, respectively while HPC...... observed from the batch reactors. Oppositely, TRX showed no inhibition in continuous mode, while inhibition was detected at batch mode....

  15. How Pacing of Multimedia Instructions Can Influence Modality Effects: A Case of Superiority of Visual Texts

    Science.gov (United States)

    Stiller, Klaus D.; Freitag, Annika; Zinnbauer, Peter; Freitag, Christian

    2009-01-01

    "Present text accompanying pictures aurally to promote learning" is a well established principle of instructional design. But recently, it was shown that under certain conditions visual texts can be preferable. Instructional pacing seems to be one of these conditions that mediate effects. Especially, enabling learners to pace an…

  16. Effect of "U-Pace" Instruction on Academic Success, Learning, and Perceptions in Younger and Older Undergraduates

    Science.gov (United States)

    Fleming, Raymond; Barth, Dylan; Weber, Nicole; Pedrick, Laura E.; Kienzler, Sarah E.; Reddy, Diane M.

    2018-01-01

    A randomized controlled trial was conducted to determine the efficacy of "U-Pace" instruction for older undergraduates, ages 25 and older, and younger undergraduates, ages 18 to 24. Additionally, change in learner perceptions across the semester, an outcome not reported in the literature on "U-Pace" instruction, was…

  17. Keeping Pace with K-12 Online & Blended Learning: An Annual Review of Policy and Practice, 2013

    Science.gov (United States)

    Watson, John; Murin, Amy; Vashaw, Lauren; Gemin, Butch; Rapp, Chris

    2013-01-01

    This is the 10th annual "Keeping Pace" report. "Keeping Pace" has several goals: (1) add to the body of knowledge about online education policy and practice, and make recommendations for advances; (2) serve as a reference source for information about programs and policies across the country, both for policymakers and…

  18. Dual Credit/Dual Enrollment and Data Driven Policy Implementation

    Science.gov (United States)

    Lichtenberger, Eric; Witt, M. Allison; Blankenberger, Bob; Franklin, Doug

    2014-01-01

    The use of dual credit has been expanding rapidly. Dual credit is a college course taken by a high school student for which both college and high school credit is given. Previous studies provided limited quantitative evidence that dual credit/dual enrollment is directly connected to positive student outcomes. In this study, predictive statistics…

  19. Efficient Control of Active Transformers for Increasing the PV Hosting Capacity of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Degner, Thomas

    2016-01-01

    . The potential interferences between the operation of active transformers and the reactive power absorption by PV inverters are investigated, and a voltage droop control approach is proposed for the efficient control of these transformers during high PV generation periods. The proposed method can potentially...... increase the PV hosting capacity of the grid, while eliminating the need for a complex and centralized controller. The voltages of specific locations or the grid state estimations provide adequate data for adjustments of the droop parameters. The simulations and field test results associated...... with the implementation of the proposed method to a newly developed active LV grid with high PV penetration in Felsberg, Germany, confirm the efficiency of the proposed method....

  20. Identification, characterization, and function analysis of the Cactus gene from Litopenaeus vannamei.

    Directory of Open Access Journals (Sweden)

    Chaozheng Li

    Full Text Available The nuclear factor-kappa B (NF-κB pathways play important roles in innate immune responses. IκB is the main cytoplasmic inhibitor of NF-κB. In this study, we identified the LvCactus gene from Litopenaeus vannamei, which is the first cloned IκB homologue in subphylum Crustacea. LvCactus contains six predicted ankyrin repeats, which show similarities to those of Cactus proteins from insects. LvCactus localizes in cytoplasm and interacts with LvDorsal, an L. vannamei homologue to Drosophila melanogaster Dorsal belonging to class II NF-κB family, to prevent its nuclear translocation. Contrary to that of LvDorsal, over-expression of LvCactus down-regulates the activities of shrimp antimicrobial peptides promoters, suggesting LvCactus is an inhibitor of LvDorsal. The promoter of LvCactus was predicted to contain five putative NF-κB binding motifs, among which four were proved to be bound by LvDorsal by chromatin immunoprecipitation assays. Dual-luciferase reporter assays also showed that transcription of LvCactus was promoted by LvDorsal but inhibited by LvCactus itself, indicating a feedback regulatory pathway between LvCactus and LvDorsal. Expression of LvCactus was up-regulated after Lipopolysaccharides, poly (I:C, Vibrio parahaemolyticus, and Staphylococcus aureus injections, suggesting an activation response of LvCactus to bacterial and immune stimulant challenges. Differently, the LvCactus expression levels obviously decreased during white spot syndrome virus (WSSV infection, indicating the feedback regulatory pathway of LvCactus/LvDorsal could be modified by WSSV.

  1. Pilot trial of an age-paced parenting newsletter.

    Science.gov (United States)

    Keane, Brigid; Waterston, Tony; McConachie, Helen; Towner, Elizabeth; Cook, Margaret; Birks, Eileen

    2005-10-01

    Supporting parents in the first three years of a child's life has the potential to produce successful outcomes. Present government initiatives such as Sure Start focus on this age group. An American educational intervention, in the style of a monthly newsletter, was adapted for use in the UK for parents of young children. Topics were presented in an easy-to-read format and focused on infant emotional development, parent interaction and play. Newsletters, called Baby Express were posted at monthly intervals to the family home providing age-paced information which could meet the specific needs of parents at that stage of their child's life. The aim of the study was to determine the applicability of the newsletter to UK parents and evaluate their satisfaction. Sixty home-based interviews were conducted and 95 per cent of mothers reported reading all or part of the newsletter. Changes in parenting style were spontaneously reported by 28 per cent of mothers. This study found that an aged-paced parenting newsletter was an acceptable and useful method of supporting parents in the early months of a child's life and promotes positive changes in parenting behaviour.

  2. Design Recommendations for Self-Paced Online Faculty Development Courses

    Science.gov (United States)

    Rizzuto, Melissa

    2017-01-01

    An increased need for self-paced, online professional development opportunities in higher education has emerged from a variety of factors including dispersed geographic locations of faculty, full teaching loads, and institutional evaluation requirements. This article is a report of the examination of the design and evaluation of a self-paced…

  3. Financial audit of antitachycardia pacing for the control of recurrent supraventricular tachycardia.

    Science.gov (United States)

    Griffith, M J; Bexton, R S; McComb, J M

    1993-03-01

    To assess the financial implications of antitachycardia pacing in patients with frequent supraventricular tachycardia. Intertach pacemakers were implanted in 25 patients (mean age 47 years, five men): 22 had atrioventricular nodal reentry tachycardia. The patients had failed a mean of 4.9 (range zero to eight) drugs and had been admitted to hospital 3.7 (zero to 31) times over a symptomatic period of 13.9 years (two months to 54 years). The mean admission time for implantation was 2.8 (two to seven) days. One patient with Wolff-Parkinson-White syndrome subsequently underwent surgery. Infection occurred in two patients, and pain over the pacemaker required its resiting in two. Two patients have had one admission each for tachycardia. Six patients remain on anti-arrhythmic drugs. Costs were calculated including value added tax, capital charges, and allocated overheads. The cost a year before pacing was 1174 pounds including drug costs, clinic visits, and hospital admissions. The mean cost of pacemaker implantation was 3364.22 pounds, including the pacemaker and lead, admission and procedure, readmissions and first pacing check. Subsequent annual follow up cost was 73.72 pounds including annual clinic visits and drug costs. The cost of pacing is 4241 pounds whereas medical management costs 7044 pounds assuming pacemaker life of six years: with a 10 year life the cost is 4537 pounds compared with 11,740 pounds: with a 12 year life the cost is 4685 pounds compared with 14,088 pounds. The excess cost of implantation of an antitachycardia pacemaker is minimal in patients with frequent supraventricular tachycardia despite drug treatment and is justified by excellent control of symptoms and reduction of drug use and hospital admissions.

  4. Wolbachia-induced loss of male fertility is likely related to branch chain amino acid biosynthesis and iLvE in Laodelphax striatellus.

    Science.gov (United States)

    Ju, Jia-Fei; Hoffmann, Ary A; Zhang, Yan-Kai; Duan, Xing-Zhi; Guo, Yan; Gong, Jun-Tao; Zhu, Wen-Chao; Hong, Xiao-Yue

    2017-06-01

    Wolbachia are endosymbionts that infect many species of arthropods and nematodes. Wolbachia-induced cytoplasmic incompatibility (CI) is the most common phenotype in affected hosts, involving embryonic lethality in crosses between Wolbachia-infected males and uninfected females. The molecular mechanisms underlying this phenomenon are currently unclear. Here we examine the molecular correlates of the Wolbachia infection in Laodelphax striatellus (Fallén), an important rice pest, where embryonic lethality is strong and almost complete. We compared the gene expression of 4-day-old Wolbachia-infected and uninfected L. striatellus testes to identify candidate genes for paternal-effect embryonic lethality induction. Based on microarray analysis, iLvE was the most down-regulated gene; this gene mediates branched-chain amino acid (BCAA) biosynthesis and participates in many processes related to reproductive performance. After knocking down iLvE by RNAi in uninfected male L. striatellus, male fertility was reduced, leading to a decrease in embryo hatching rates, but fertility was rescued in crosses between these males and Wolbachia-infected females. Removal of BCAA in chemically-defined diets of uninfected males also led to a loss of male fertility. Low amino acid nutrition may enhance exposure time of sperm to Wolbachia in the testes to affect adult reproduction in L. striatellus by reducing the number of sperm transferred per mating by males. These results indicate that Wolbachia may decrease male fertility in L. striatellus by acting on iLvE, a key factor of BCAA biosynthesis, and delaying sperm maturation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Financing the Business. PACE Revised. Level 1. Unit 8. Research & Development Series No. 240AB8.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on financing a business, the eighth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  6. Self-Paced Prioritized Curriculum Learning With Coverage Penalty in Deep Reinforcement Learning.

    Science.gov (United States)

    Ren, Zhipeng; Dong, Daoyi; Li, Huaxiong; Chen, Chunlin; Zhipeng Ren; Daoyi Dong; Huaxiong Li; Chunlin Chen; Dong, Daoyi; Li, Huaxiong; Chen, Chunlin; Ren, Zhipeng

    2018-06-01

    In this paper, a new training paradigm is proposed for deep reinforcement learning using self-paced prioritized curriculum learning with coverage penalty. The proposed deep curriculum reinforcement learning (DCRL) takes the most advantage of experience replay by adaptively selecting appropriate transitions from replay memory based on the complexity of each transition. The criteria of complexity in DCRL consist of self-paced priority as well as coverage penalty. The self-paced priority reflects the relationship between the temporal-difference error and the difficulty of the current curriculum for sample efficiency. The coverage penalty is taken into account for sample diversity. With comparison to deep Q network (DQN) and prioritized experience replay (PER) methods, the DCRL algorithm is evaluated on Atari 2600 games, and the experimental results show that DCRL outperforms DQN and PER on most of these games. More results further show that the proposed curriculum training paradigm of DCRL is also applicable and effective for other memory-based deep reinforcement learning approaches, such as double DQN and dueling network. All the experimental results demonstrate that DCRL can achieve improved training efficiency and robustness for deep reinforcement learning.

  7. Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation

    NARCIS (Netherlands)

    Lahaije, A.J.M.C.; Willems, L.M.; Hees, H.W. van; Dekhuijzen, P.N.R.; Helvoort, H.A.C. van; Heijdra, Y.F.

    2013-01-01

    INTRODUCTION: This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this

  8. Amplitude and phase dynamics associated with acoustically paced finger tapping

    NARCIS (Netherlands)

    Boonstra, T.W.; Daffertshofer, A.; Peper, C.E.; Beek, P.J.

    2006-01-01

    To gain insight into the brain activity associated with the performance of an acoustically paced synchronization task, we analyzed the amplitude and phase dynamics inherent in magnetoencephalographic (MEG) signals across frequency bands in order to discriminate between evoked and induced responses.

  9. The downside of downtime: The prevalence and work pacing consequences of idle time at work.

    Science.gov (United States)

    Brodsky, Andrew; Amabile, Teresa M

    2018-05-01

    Although both media commentary and academic research have focused much attention on the dilemma of employees being too busy, this paper presents evidence of the opposite phenomenon, in which employees do not have enough work to fill their time and are left with hours of meaningless idle time each week. We conducted six studies that examine the prevalence and work pacing consequences of involuntary idle time. In a nationally representative cross-occupational survey (Study 1), we found that idle time occurs frequently across all occupational categories; we estimate that employers in the United States pay roughly $100 billion in wages for time that employees spend idle. Studies 2a-3b experimentally demonstrate that there are also collateral consequences of idle time; when workers expect idle time following a task, their work pace declines and their task completion time increases. This decline reverses the well-documented deadline effect, producing a deadtime effect, whereby workers slow down as a task progresses. Our analyses of work pace patterns provide evidence for a time discounting mechanism: workers discount idle time when it is relatively distant, but act to avoid it increasingly as it becomes more proximate. Finally, Study 4 demonstrates that the expectation of being able to engage in leisure activities during posttask free time (e.g., surfing the Internet) can mitigate the collateral work pace losses due to idle time. Through examination and discussion of the effects of idle time at work, we broaden theory on work pacing. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  10. Failure of communication and capture: The perils of temporary unipolar pacing system

    Directory of Open Access Journals (Sweden)

    Efe Sahinoglu, BChE

    2015-06-01

    Full Text Available We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  11. Challenge of engaging all students via self-paced interactive electronic learning tutorials for introductory physics

    Directory of Open Access Journals (Sweden)

    Seth DeVore

    2017-05-01

    Full Text Available As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar introductory physics courses and then propose a framework for helping students engage effectively with the learning tools. The tutorials were developed via research in physics education and were found to be effective for a diverse group of introductory physics students in one-on-one implementation. Instructors encouraged the use of these tools in a self-paced learning environment by telling students that they would be helpful for solving the assigned homework problems and that the underlying physics principles in the tutorial problems would be similar to those in the in-class quizzes (which we call paired problems. We find that many students in the courses in which these interactive electronic learning tutorials were assigned as a self-study tool performed poorly on the paired problems. In contrast, a majority of student volunteers in one-on-one implementation greatly benefited from the tutorials and performed well on the paired problems. The significantly lower overall performance on paired problems administered as an in-class quiz compared to the performance of student volunteers who used the research-based tutorials in one-on-one implementation suggests that many students enrolled in introductory physics courses did not effectively engage with the tutorials outside of class and may have only used them superficially. The findings suggest that many students in need of out-of-class remediation via self-paced learning tools may have difficulty motivating themselves and may lack the self-regulation and time-management skills to engage effectively with tools specially designed to help them learn at their

  12. Challenge of engaging all students via self-paced interactive electronic learning tutorials for introductory physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-06-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar introductory physics courses and then propose a framework for helping students engage effectively with the learning tools. The tutorials were developed via research in physics education and were found to be effective for a diverse group of introductory physics students in one-on-one implementation. Instructors encouraged the use of these tools in a self-paced learning environment by telling students that they would be helpful for solving the assigned homework problems and that the underlying physics principles in the tutorial problems would be similar to those in the in-class quizzes (which we call paired problems). We find that many students in the courses in which these interactive electronic learning tutorials were assigned as a self-study tool performed poorly on the paired problems. In contrast, a majority of student volunteers in one-on-one implementation greatly benefited from the tutorials and performed well on the paired problems. The significantly lower overall performance on paired problems administered as an in-class quiz compared to the performance of student volunteers who used the research-based tutorials in one-on-one implementation suggests that many students enrolled in introductory physics courses did not effectively engage with the tutorials outside of class and may have only used them superficially. The findings suggest that many students in need of out-of-class remediation via self-paced learning tools may have difficulty motivating themselves and may lack the self-regulation and time-management skills to engage effectively with tools specially designed to help them learn at their own pace. We

  13. Introduction to Physics (Mechanics): A Semi-Self Paced Approach.

    Science.gov (United States)

    Schlenker, Richard M.

    Presented is a guide for an introductory college level physics course in mechanics. The course is contract graded and allows students to proceed at their own pace; however, lectures, problem solving sessions, and laboratory sessions are included. Students on an independent basis review video tapes, film loops, library study, and conduct an…

  14. Pacing Profiles in Competitive Track Races: Regulation of Exercise Intensity is related to Cognitive Ability

    Directory of Open Access Journals (Sweden)

    Debbie Van Biesen

    2016-12-01

    Full Text Available Pacing has been defined as the goal-directed regulation of exercise intensity over an exercise bout, in which athletes need to decide how and when to invest their energy. The purpose of this study was to explore if the regulation of exercise intensity during competitive track races is different between runners with and without intellectual impairment, which is characterized by significant limitations in intellectual functioning (IQ≤75 and adaptive behavioral deficits, diagnosed before the age of 18. The samples included elite runners with intellectual impairment (N= 36 and a comparison group of world class runners without impairment (N= 39, of which 47 were 400m runners (all male and 28 were 1500m-runners (15 male and 13 female. Pacing was analysed by means of 100m split times (for 400m races and 200m split times (for 1500m races. Based on the split times, the average velocity was calculated for four segments of the races. Velocity fluctuations were defined as the differences in velocity between consecutive race segments. A mixed model ANOVA revealed significant differences in pacing profiles between runners with and without intellectual impairment (p<.05. Maximal velocity of elite 400m runners with intellectual impairment in the first race segment (7.9 ± 0.3 m/s was well below the top-velocity reached by world level 400m runners without intellectual impairment (8.9 ±0.2 m/s, and their overall pace was slower (F=120.7, p<.05. In addition, both groups followed a different pacing profile and inter-individual differences in pacing profiles were larger, with differences most pronounced for 1500m races. Whereas male 1500m-runners without intellectual impairment reached a high velocity in the first 100m (7.2±0.1 m/s, slowly decelerated in the second race segment (-0.6±0.1 m/s, and finished with an end sprint (+0.9±0.1 m/s; the 1500m runners with intellectual impairment started slower (6.1±0.3 m/s, accelerated in the second segment (+ 0.2±0

  15. Randomized placebo controlled blinded study to assess valsartan efficacy in preventing left ventricle remodeling in patients with dual chamber pacemaker--Rationale and design of the trial.

    Science.gov (United States)

    Tomasik, Andrzej; Jacheć, Wojciech; Wojciechowska, Celina; Kawecki, Damian; Białkowska, Beata; Romuk, Ewa; Gabrysiak, Artur; Birkner, Ewa; Kalarus, Zbigniew; Nowalany-Kozielska, Ewa

    2015-05-01

    Dual chamber pacing is known to have detrimental effect on cardiac performance and heart failure occurring eventually is associated with increased mortality. Experimental studies of pacing in dogs have shown contractile dyssynchrony leading to diffuse alterations in extracellular matrix. In parallel, studies on experimental ischemia/reperfusion injury have shown efficacy of valsartan to inhibit activity of matrix metalloproteinase-9, to increase the activity of tissue inhibitor of matrix metalloproteinase-3 and preserve global contractility and left ventricle ejection fraction. To present rationale and design of randomized blinded trial aimed to assess whether 12 month long administration of valsartan will prevent left ventricle remodeling in patients with preserved left ventricle ejection fraction (LVEF ≥ 40%) and first implantation of dual chamber pacemaker. A total of 100 eligible patients will be randomized into three parallel arms: placebo, valsartan 80 mg/daily and valsartan 160 mg/daily added to previously used drugs. The primary endpoint will be assessment of valsartan efficacy to prevent left ventricle remodeling during 12 month follow-up. We assess patients' functional capacity, blood plasma activity of matrix metalloproteinases and their tissue inhibitors, NT-proBNP, tumor necrosis factor alpha, and Troponin T. Left ventricle function and remodeling is assessed echocardiographically: M-mode, B-mode, tissue Doppler imaging. If valsartan proves effective, it will be an attractive measure to improve long term prognosis in aging population and increasing number of pacemaker recipients. ClinicalTrials.org (NCT01805804). Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Increased heart rate caused by atrial pacing with the closed-loop stimulation function prevented micturition syncope

    Directory of Open Access Journals (Sweden)

    Tatsuo Haraki, MD,PhD

    2013-10-01

    Full Text Available A 70-year-old man had been experiencing syncope several times a year. We implanted a DDD pacemaker with closed-loop stimulation (CLS function. When he urinated early in the morning, his increased atrial pacing rates elevated his heart rate (HR during and after micturition. After implantation of the DDD-CLS mode, he did not experience symptoms. In contrast, in the DDD-R mode, his intrinsic HR changed to atrial pacing after micturition but decreased to the basal rate within 2 min, and he experienced a sense of cold perspiration and presyncope. Increased HRs caused by atrial pacing with the CLS function were useful in the prevention of micturition syncope.

  17. Energy levels, lifetimes and radiative data of W LV

    Science.gov (United States)

    Ding, Xiao-bin; Sun, Rui; Koike, Fumihiro; Murakami, Izumi; Kato, Daiji; Sakaue, Hiroyuki A.; Nakamura, Nobuyuki; Dong, Chen-zhong

    2018-01-01

    Calculations of energy levels, radiative data and lifetimes are reported for tungsten Ca-like ion (W LV) by using multi-configuration Dirac-Fock (MCDF) method. The GRASP2K package is adopted to carry out a large-scale systematic computation with a restricted active space treatment; the Breit interaction and QED effects are included in subsequent relativistic configuration interaction calculations. The energies and lifetimes of the lowest 119 levels are listed; the main leading configuration of the levels is of the ground state configuration [Ne]3s23p63d2 and the first excited configuration [Ne]3s23p53d3. The wavelengths, radiative rates and oscillator strengths for relatively strong E1, E2, M1, and M2 transitions are listed. Comparisons with earlier experimental and theoretical values are made. The average relative deviations of energy levels from the NIST results and E1 transition wavelengths from the EBIT experimental results have turned to be only 0.20% and 0.13%, respectively. The other present results are in reasonable agreement with available data. These agreements confirm the reliability and accuracy of the current results. The present datasets may help us with the investigation of the electron-electron correlation effects in complex multi-electron highly charged heavy ions and of the diagnosis of tungsten impurity plasmas in fusion science.

  18. A positron emission tomography study of self-paced finger movements at different frequencies

    International Nuclear Information System (INIS)

    Kawashima, R.; Inoue, K.; Sugiura, M.; Okada, K.; Ogawa, A.; Fukuda, H.

    1999-01-01

    Regional cerebral blood flow was measured in six right-handed volunteers using positron emission tomography during tasks involving repetitive self-paced finger tapping at five different frequencies. The contralateral primary sensorimotor cortex, the pre-supplementary motor area and the cingulate motor area showed significant activation during self-paced finger tapping tasks, compared with the resting state. A positive correlation between the regional cerebral blood flow and the movement frequency was found only in the primary sensorimotor cortex. In the pre-supplementary motor area and the cingulate motor area, however, activity increased when the subject employed movement frequencies faster or slower than his own pace. The same tendency was noted with respect to the relative variability of the inter-tapping interval.The results therefore indicate that the activity of the pre-supplementary motor area and the cingulate motor area may well be related to the increased difficulty in motor control rather than to the execution of the movement itself. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  19. Evolutionary traces decode molecular mechanism behind fast pace of myosin XI

    Directory of Open Access Journals (Sweden)

    Syamaladevi Divya P

    2011-09-01

    Full Text Available Abstract Background Cytoplasmic class XI myosins are the fastest processive motors known. This class functions in high-velocity cytoplasmic streaming in various plant cells from algae to angiosperms. The velocities at which they process are ten times faster than its closest class V homologues. Results To provide sequence determinants and structural rationale for the molecular mechanism of this fast pace myosin, we have compared the sequences from myosin class V and XI through Evolutionary Trace (ET analysis. The current study identifies class-specific residues of myosin XI spread over the actin binding site, ATP binding site and light chain binding neck region. Sequences for ET analysis were accumulated from six plant genomes, using literature based text search and sequence searches, followed by triple validation viz. CDD search, string-based searches and phylogenetic clustering. We have identified nine myosin XI genes in sorghum and seven in grape by sequence searches. Both the plants possess one gene product each belonging to myosin type VIII as well. During this process, we have re-defined the gene boundaries for three sorghum myosin XI genes using fgenesh program. Conclusion Molecular modelling and subsequent analysis of putative interactions involving these class-specific residues suggest a structural basis for the molecular mechanism behind high velocity of plant myosin XI. We propose a model of a more flexible switch I region that contributes to faster ADP release leading to high velocity movement of the algal myosin XI.

  20. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  1. The Effects of Self-Paced Blended Learning of Mathematics

    Science.gov (United States)

    Balentyne, Phoebe; Varga, Mary Alice

    2016-01-01

    As online and blended learning gain more popularity in education, it becomes more important to understand their effects on student learning. The purpose of this study was to explore the effects of self-paced blended learning of mathematics on the attitudes and achievement of 26 high ability middle school students, and investigate the relationship…

  2. Similarities and Differences in Pacing Patterns in a 161-km and 101-km Ultra-Distance Road Race.

    Science.gov (United States)

    Tan, Philip L S; Tan, Frankie H Y; Bosch, Andrew N

    2016-08-01

    Tan, PLS, Tan, FHY, and Bosch, AN. Similarities and differences in pacing patterns in a 161-km and 101-km ultra-distance road race. J Strength Cond Res 30(8): 2145-2155, 2016-The purpose of this study was to establish and compare the pacing patterns of fast and slow finishers in a tropical ultra-marathon. Data were collected from the Craze Ultra-marathon held on the 22nd and 21st of September in 2012 and 2013, respectively. Finishers of the 161-km (N = 47) and 101-km (N = 120) categories of the race were divided into thirds (groups A-C) by merit of finishing time. Altogether, 17 and 11 split times were recorded for the 161-km and 101-km finishers, respectively, and used to calculate the mean running speed for each distance segment. Running speed for the first segment was normalized to 100, with all subsequent splits adjusted accordingly. Running speed during the last 5 km was calculated against the mean race pace to establish the existence of an end spurt. A reverse J-shaped pacing profile was demonstrated in all groups for both distance categories and only 38% of the finishers executed an end spurt. In the 101-km category, in comparison with groups B and C, group A maintained a significantly more even pace (p = 0.013 and 0.001, respectively) and completed the race at a significantly higher percent of initial starting speed (p = 0.001 and 0.001, respectively). Descriptive data also revealed that the top 5 finishers displayed a "herd-behavior" by staying close to the lead runner in the initial portion of the race. These findings demonstrate that to achieve a more even pace, recreational ultra-runners should adopt a patient sustainable starting speed, with less competitive runners setting realistic performance goals whereas competitive runners with a specific time goal to consider running in packs of similar pace.

  3. Risk management at hazardous waste sites

    International Nuclear Information System (INIS)

    Travis, C.C.; Doty, C.B.

    1990-01-01

    The Superfund Amendments and Reauthorization Act of 1986 (SARA) provided the Environmental Protection Agency (EPA) with additional resources and direction for the identification, evaluation, and remediation of hazardous waste sites in the United States. SARA established more stringent requirements for the Superfund program, both in terms of the pace of the program and the types of remedial alternatives selected. The central requirement is that remedial alternatives be ''protective of public health and the environment'' and ''significantly and permanently'' reduce the toxicity, mobility, or volume of contaminants. The mandate also requires that potential risk be considered in the decision-making process. This document discusses risk management at hazardous waste sites. Topics include selection of sites for placement on the National Priority List, risk assessment and the decision process, risk reduction and remedial alternative selection, and aquifer restoration. 10 refs., 2 figs

  4. Does reducing unnecessary right ventricular pacing improve sympathetic activity and innervation of heart in sinus node disease patients? MVP and SafeR study.

    Science.gov (United States)

    Miyamoto, Mihoko; Kimura, Yuichiro; Hosoda, Junya; Matsumoto, Katsumi; Matsushita, Kohei; Ishikawa, Toshiyuki; Umemura, Satoshi

    2012-01-01

    Ventricular desynchronization imposed by ventricular pacing causes regional disturbances of adrenergic innervation in the left ventricular myocardium and increases the risk of heart failure and atrial fibrillation (AF) in patients with sinus node disease (SND). As a result, decreased iodine-123 metaiodobenzylguanidine (I-(123 )MIBG) uptake occurs in patients with an implanted permanent pacemaker. Fourteen SND patients with an implanted pacemaker equipped with an algorithm for reducing unnecessary right ventricular pacing (RURVP) were enrolled. Pacemakers were programmed to RURVP mode for the first 12 weeks, and then reprogrammed to DDD for the last 12 weeks. At the end of each mode, data on cumulative percent ventricular pacing (%Vp), atrial high rate episodes (%AHR), I-(123 )MIBG myocardial scintigraphy, brain natriuretic peptide (BNP), human atrial natriuretic peptide (hANP), and myocardial damage indices typified by troponin T and C-reactive protein (CRP) were collected. %Vp was lower in RURVP than in DDD (0.2% versus 95.7%, P = 0.00098). BNP, hANP, troponin T, and CRP did not differ significantly between the pacing modes. However, I-(123 )MIBG findings of patients with full ventricular pacing in DDD improved in RURVP. In contrast, among patients without full ventricular pacing in DDD, their I-(123 )MIBG findings did not differ significantly between the pacing modes. In SND patients with normal cardiac function and intact atrioventricular conduction, the reduction of %Vp in RURVP was due to the reduction of ineffective pacing and fusion pacing in DDD. Therefore, these 2 types of pacing do not affect cardiac pump function.

  5. Impact of physiological variables and genetic background on myocardial frequency-resistivity relations in the intact beating murine heart.

    Science.gov (United States)

    Reyes, Maricela; Steinhelper, Mark E; Alvarez, Jorge A; Escobedo, Daniel; Pearce, John; Valvano, Jonathan W; Pollock, Brad H; Wei, Chia-Ling; Kottam, Anil; Altman, David; Bailey, Steven; Thomsen, Sharon; Lee, Shuko; Colston, James T; Oh, Jung Hwan; Freeman, Gregory L; Feldman, Marc D

    2006-10-01

    Conductance measurements for generation of an instantaneous left ventricular (LV) volume signal in the mouse are limited, because the volume signal is a combination of blood and LV muscle, and only the blood signal is desired. We have developed a conductance system that operates at two simultaneous frequencies to identify and remove the myocardial contribution to the instantaneous volume signal. This system is based on the observation that myocardial resistivity varies with frequency, whereas blood resistivity does not. For calculation of LV blood volume with the dual-frequency conductance system in mice, in vivo murine myocardial resistivity was measured and combined with an analytic approach. The goals of the present study were to identify and minimize the sources of error in the measurement of myocardial resistivity to enhance the accuracy of the dual-frequency conductance system. We extended these findings to a gene-altered mouse model to determine the impact of measured myocardial resistivity on the calculation of LV pressure-volume relations. We examined the impact of temperature, timing of the measurement during the cardiac cycle, breeding strain, anisotropy, and intrameasurement and interanimal variability on the measurement of intact murine myocardial resistivity. Applying this knowledge to diabetic and nondiabetic 11- and 20- to 24-wk-old mice, we demonstrated differences in myocardial resistivity at low frequencies, enhancement of LV systolic function at 11 wk and LV dilation at 20-24 wk, and histological and electron-microscopic studies demonstrating greater glycogen deposition in the diabetic mice. This study demonstrated the accurate technique of measuring myocardial resistivity and its impact on the determination of LV pressure-volume relations in gene-altered mice.

  6. Gait Coordination After Stroke: Benefits of Acoustically Paced Treadmill Walking

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.C.; Kwakkel, G.; van Wieringen, P.C.W.; Beek, P.J.

    2007-01-01

    Background and Purpose: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. Participants: Ten people after stroke volunteered for the

  7. Gait coordination after stroke: benefits of acoustically paced treadmill walking.

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.; Kwakkel, G.; Wieringen, P.C. van; Beek, P.J.

    2007-01-01

    BACKGROUND AND PURPOSE: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. PARTICIPANTS: Ten people after stroke volunteered for the

  8. Momentum-space cluster dual-fermion method

    Science.gov (United States)

    Iskakov, Sergei; Terletska, Hanna; Gull, Emanuel

    2018-03-01

    Recent years have seen the development of two types of nonlocal extensions to the single-site dynamical mean field theory. On one hand, cluster approximations, such as the dynamical cluster approximation, recover short-range momentum-dependent correlations nonperturbatively. On the other hand, diagrammatic extensions, such as the dual-fermion theory, recover long-ranged corrections perturbatively. The correct treatment of both strong short-ranged and weak long-ranged correlations within the same framework is therefore expected to lead to a quick convergence of results, and offers the potential of obtaining smooth self-energies in nonperturbative regimes of phase space. In this paper, we present an exact cluster dual-fermion method based on an expansion around the dynamical cluster approximation. Unlike previous formulations, our method does not employ a coarse-graining approximation to the interaction, which we show to be the leading source of error at high temperature, and converges to the exact result independently of the size of the underlying cluster. We illustrate the power of the method with results for the second-order cluster dual-fermion approximation to the single-particle self-energies and double occupancies.

  9. Environmental proxies of antigen exposure explain variation in immune investment better than indices of pace of life.

    Science.gov (United States)

    Horrocks, Nicholas P C; Hegemann, Arne; Ostrowski, Stéphane; Ndithia, Henry; Shobrak, Mohammed; Williams, Joseph B; Matson, Kevin D; Tieleman, B I

    2015-01-01

    Investment in immune defences is predicted to covary with a variety of ecologically and evolutionarily relevant axes, with pace of life and environmental antigen exposure being two examples. These axes may themselves covary directly or inversely, and such relationships can lead to conflicting predictions regarding immune investment. If pace of life shapes immune investment then, following life history theory, slow-living, arid zone and tropical species should invest more in immunity than fast-living temperate species. Alternatively, if antigen exposure drives immune investment, then species in antigen-rich tropical and temperate environments are predicted to exhibit higher immune indices than species from antigen-poor arid locations. To test these contrasting predictions we investigated how variation in pace of life and antigen exposure influence immune investment in related lark species (Alaudidae) with differing life histories and predicted risks of exposure to environmental microbes and parasites. We used clutch size and total number of eggs laid per year as indicators of pace of life, and aridity, and the climatic variables that influence aridity, as correlates of antigen abundance. We quantified immune investment by measuring four indices of innate immunity. Pace of life explained little of the variation in immune investment, and only one immune measure correlated significantly with pace of life, but not in the predicted direction. Conversely, aridity, our proxy for environmental antigen exposure, was predictive of immune investment, and larks in more mesic environments had higher immune indices than those living in arid, low-risk locations. Our study suggests that abiotic environmental variables with strong ties to environmental antigen exposure can be important correlates of immunological variation.

  10. Pacing, packing and sex-based differences in Olympic and IAAF World Championship marathons.

    Science.gov (United States)

    Hanley, Brian

    2016-09-01

    The aim of this study was to describe pacing profiles and packing behaviours of athletes in Olympic and World Championship marathons. Finishing and split times were collated for 673 men and 549 women across nine competitions. The mean speeds for each intermediate 5 km and end 2.2 km segments were calculated. Medallists of both sexes maintained even-paced running from 10 km onwards whereas slower finishers dropped off the lead pack at approximately half-distance. Athletes who ran with the same opponents throughout slowed the least in the second half (P tactics adopted and design training programmes accordingly.

  11. Antifibrillatory effects of renal denervation on ventricular fibrillation in a canine model of pacing-induced heart failure.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Huang, Shangwei; Han, Yanxin; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2018-01-01

    What is the central question of this study? In the present study, we investigated the effects of renal denervation on the vulnerability to ventricular fibrillation and the ventricular electrical properties in a rapid pacing-induced heart failure canine model. What is the main finding and its importance? Renal denervation significantly attenuated the process of heart failure and improved left ventricular systolic dysfunction, stabilized ventricular electrophysiological properties and decreased the vulnerability of the heart to ventricular fibrillation during heart failure. Thus, renal denervation can attenuate ventricular electrical remodelling and exert a potential antifibrillatory action in a pacing-induced heart failure canine model. In this study, we investigated the effects of renal denervation (RDN) on the vulnerability to ventricular fibrillation (VF) and the ventricular electrical properties in a canine model of pacing-induced heart failure (HF). Eighteen beagles were divided into the following three groups: control (n = 6), HF (n = 6) and HF+RDN (n = 6). Heart failure was induced by rapid right ventricular pacing. Renal denervation was performed simultaneously with the pacemaker implantation in the HF+RDN group. A 64-unipolar basket catheter was used to perform global endocardial mapping of the left ventricle. The restitution properties and dispersion of refractoriness were estimated from the activation recovery intervals (ARIs) by a pacing protocol. The VF threshold (VFT) was defined as the maximal pacing cycle length required to induce VF using a specific pacing protocol. The defibrillation threshold (DFT) was measured by an up-down algorithm. Renal denervation partly restored left ventricular systolic function and attenuated the process of HF. Compared with the control group, the VFT in the HF group was decreased by 27% (106 ± 8.0 versus 135 ± 10 ms, P Renal denervation significantly flattened the ventricular ARI restitution curve by 15% (1

  12. Effect of Music Tempo on Attentional Focus and Perceived Exertion during Self-selected Paced Walking

    OpenAIRE

    SILVA, ALDO COELHO; DOS SANTOS FERREIRA, SANDRO; ALVES, RAGAMI CHAVES; FOLLADOR, LUCIO; DA SILVA, SERGIO GREGORIO

    2016-01-01

    This study investigated the influence of music on the rating of perceived exertion (RPE) and attentional focus during walking at a self-selected pace. Fifteen overweight and obese women volunteered to participate in the study. They underwent four sessions: the first for incremental maximal test and anthropometric measurement followed by three experimental sessions. After the first session, they were exposed to three 30-minute walking sessions at a self-selected pace in a counterbalanced order...

  13. Hardware packet pacing using a DMA in a parallel computer

    Science.gov (United States)

    Chen, Dong; Heidelberger, Phillip; Vranas, Pavlos

    2013-08-13

    Method and system for hardware packet pacing using a direct memory access controller in a parallel computer which, in one aspect, keeps track of a total number of bytes put on the network as a result of a remote get operation, using a hardware token counter.

  14. The Self-Paced Graz Brain-Computer Interface: Methods and Applications

    Directory of Open Access Journals (Sweden)

    Reinhold Scherer

    2007-01-01

    Full Text Available We present the self-paced 3-class Graz brain-computer interface (BCI which is based on the detection of sensorimotor electroencephalogram (EEG rhythms induced by motor imagery. Self-paced operation means that the BCI is able to determine whether the ongoing brain activity is intended as control signal (intentional control or not (non-control state. The presented system is able to automatically reduce electrooculogram (EOG artifacts, to detect electromyographic (EMG activity, and uses only three bipolar EEG channels. Two applications are presented: the freeSpace virtual environment (VE and the Brainloop interface. The freeSpace is a computer-game-like application where subjects have to navigate through the environment and collect coins by autonomously selecting navigation commands. Three subjects participated in these feedback experiments and each learned to navigate through the VE and collect coins. Two out of the three succeeded in collecting all three coins. The Brainloop interface provides an interface between the Graz-BCI and Google Earth.

  15. Spatial characterization of electrogram morphology from transmural recordings in the intact normal heart.

    Directory of Open Access Journals (Sweden)

    Jim Pouliopoulos

    Full Text Available PURPOSE: Unipolar (UE and bipolar electrograms (BE are utilized to identify arrhythmogenic substrate. We quantified the effect of increasing distance from the source of propagation on local electrogram amplitude; and determined if transmural electrophysiological gradients exist with respect to propagation and stimulation depth. METHODS: Mapping was performed on 5 sheep. Deployment of >50 quadripolar transmural needles in the LV were located in Cartesian space using Ensite. Contact electrograms from all needles were recorded during multisite bipolar pacing from epicardial then endocardial electrodes. Analysis was performed to determine stimulus distance to local activation time, peak negative amplitude (V-P, and peak-peak amplitude (VP-P for (1 unfiltered UE, and (2 unfiltered and 30 Hz high-pass filtered BEs. Each sheep was analysed using repeated ANOVA. RESULTS: Increasing distance from the pacing sites led to significant (p0.01 during endocardial stimulation, and 2.3±2.4 ms (UE and 1.8±3.7 ms (BE during epicardal stimulation (all pVP-P. Conduction propagates preferentially via the epicardium during stimulation and is believed to contribute to a transmural amplitude gradient.

  16. Improvement of water and light availability after thinning at a xeric site: which matters more? A dual isotope approach.

    Science.gov (United States)

    Giuggiola, Arnaud; Ogée, Jérôme; Rigling, Andreas; Gessler, Arthur; Bugmann, Harald; Treydte, Kerstin

    2016-04-01

    Thinning fosters individual tree growth by increasing the availability of water, light and nutrients. At sites where water rather than light is limiting, thinning also enhances soil evaporation and might not be beneficial. Detailed knowledge of the short- to long-term physiological response underlying the growth responses to thinning is crucial for the management of forests already suffering from recurrent drought-induced dieback. We applied a dual isotope approach together with mechanistic isotope models to study the physiological processes underlying long-term growth enhancement of heavily thinned Pinus sylvestris in a xeric forest in Switzerland. This approach allowed us to identify and disentangle thinning-induced changes in stomatal conductance and assimilation rate. At our xeric study site, the increase in stomatal conductance far outweighed the increase in assimilation, implying that growth release in heavily thinned trees is primarily driven by enhanced water availability rather than increased light availability. We conclude that in forests with relatively isohydric species (drought avoiders) that are growing close to their physiological limits, thinning is recommended to maintain a less negative water balance and thus foster tree growth, and ultimately the survival of forest trees under drought. © 2015 The Authors. New Phytologist © 2015 New Phytologist Trust.

  17. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    Science.gov (United States)

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Planning the Marketing Strategy. PACE Revised. Level 1. Unit 6. Research & Development Series No. 240AB6.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on planning a marketing strategy, the sixth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  19. [The use of auto mode switching in patients with sick sinus syndrome].

    Science.gov (United States)

    Vlasínová, J

    2005-01-01

    At present the dual chamber pacing, originally developed for patients with AV blockades, is widely used also for patients with Sick sinus syndrome (tachycardic-bradycardic type). But these patients often cause therapeutical problems to their physicians. In these cases either antiarrhythmic therapy is necessary to prevent recurrent supraventricular tachycardias (which are cause of rapid ventricular pacing) or in the case of failure of AA therapy the pacing mode has to be changed to DDI/R, which excludes physiological VAT pacing. The Auto Mode Switching (AMS) function ensures adequate ventricular pacing rate in the time of SV arrhythmias. Effects of dual chamber pacemakers equipped with AMS were studied in a group of patients with paroxysmal atrial fibrilation and/or atrial flutter. Therapy brings effects in lower of expenses due to less frequent visits at the physician, lower rate of rehospitalizations and lower need for powerful AA therapy.

  20. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.

  1. Deployment of IPv6-only CPU resources at WLCG sites

    Science.gov (United States)

    Babik, M.; Chudoba, J.; Dewhurst, A.; Finnern, T.; Froy, T.; Grigoras, C.; Hafeez, K.; Hoeft, B.; Idiculla, T.; Kelsey, D. P.; López Muñoz, F.; Martelli, E.; Nandakumar, R.; Ohrenberg, K.; Prelz, F.; Rand, D.; Sciabà, A.; Tigerstedt, U.; Traynor, D.

    2017-10-01

    The fraction of Internet traffic carried over IPv6 continues to grow rapidly. IPv6 support from network hardware vendors and carriers is pervasive and becoming mature. A network infrastructure upgrade often offers sites an excellent window of opportunity to configure and enable IPv6. There is a significant overhead when setting up and maintaining dual-stack machines, so where possible sites would like to upgrade their services directly to IPv6 only. In doing so, they are also expediting the transition process towards its desired completion. While the LHC experiments accept there is a need to move to IPv6, it is currently not directly affecting their work. Sites are unwilling to upgrade if they will be unable to run LHC experiment workflows. This has resulted in a very slow uptake of IPv6 from WLCG sites. For several years the HEPiX IPv6 Working Group has been testing a range of WLCG services to ensure they are IPv6 compliant. Several sites are now running many of their services as dual-stack. The working group, driven by the requirements of the LHC VOs to be able to use IPv6-only opportunistic resources, continues to encourage wider deployment of dual-stack services to make the use of such IPv6-only clients viable. This paper presents the working group’s plan and progress so far to allow sites to deploy IPv6-only CPU resources. This includes making experiment central services dual-stack as well as a number of storage services. The monitoring, accounting and information services that are used by jobs also need to be upgraded. Finally the VO testing that has taken place on hosts connected via IPv6-only is reported.

  2. Pacing and decision making in sport and exercise: the roles of perception and action in the regulation of exercise intensity.

    Science.gov (United States)

    Smits, Benjamin L M; Pepping, Gert-Jan; Hettinga, Florentina J

    2014-06-01

    In pursuit of optimal performance, athletes and physical exercisers alike have to make decisions about how and when to invest their energy. The process of pacing has been associated with the goal-directed regulation of exercise intensity across an exercise bout. The current review explores divergent views on understanding underlying mechanisms of decision making in pacing. Current pacing literature provides a wide range of aspects that might be involved in the determination of an athlete's pacing strategy, but lacks in explaining how perception and action are coupled in establishing behaviour. In contrast, decision-making literature rooted in the understanding that perception and action are coupled provides refreshing perspectives on explaining the mechanisms that underlie natural interactive behaviour. Contrary to the assumption of behaviour that is managed by a higher-order governor that passively constructs internal representations of the world, an ecological approach is considered. According to this approach, knowledge is rooted in the direct experience of meaningful environmental objects and events in individual environmental processes. To assist a neuropsychological explanation of decision making in exercise regulation, the relevance of the affordance competition hypothesis is explored. By considering pacing as a behavioural expression of continuous decision making, new insights on underlying mechanisms in pacing and optimal performance can be developed.

  3. Effect of Psychological Intervention on Marital Satisfaction of Mothers with Slow Pace Under 5 Years Children

    Directory of Open Access Journals (Sweden)

    Mehran Soleymani

    2012-04-01

    Full Text Available Objectives: Objective of this study was investigating impact of early psychological interventions on marital satisfaction of mothers with slow pace under 5 years children. Considering variables of the research, that is, early psychological interventions and marital satisfaction, research hypotheses was as follows: "early psychological interventions affect marital satisfaction of mothers with slow pace under 5 years children" and it was examined. Methods: This research is of experimental type and pretest-posttest plan with control groups was used. Statistical population included all mothers with slow pace under 5 years children in Urmia. To this end, 40 mothers with slow pace children were selected as the sample in a non-random manner by convenience sampling. They were assigned randomly into two groups of 20 (20 test group and 20 control group, and finally psychological interventions were conducted on one of groups randomly. In order to evaluate marital satisfaction, Enrich marital satisfaction questionnaire with 47 items was used. Data were analyzed by univariate analysis of covariance. Results: findings showed that there is significant difference between two groups in posttest in overall score of marital satisfaction as well as in some elements such as conventional responses, marital satisfaction, personality issues, marital relationships, conflict resolution, leisure, parenting, family and friends, and ideological orientation and sexual relations (P<0.005, and no significant difference was observed in financial supervision and roles related to gender equality. Discusion: Psychological interventions were effective in promoting marital satisfaction in mothers with slow pace under 5 years children.

  4. Cerebellar abnormalities contribute to disability including cognitive impairment in multiple sclerosis.

    Directory of Open Access Journals (Sweden)

    Katrin Weier

    Full Text Available The cerebellum is known to be involved not only in motor but also cognitive and affective processes. Structural changes in the cerebellum in relation to cognitive dysfunction are an emerging topic in the field of neuro-psychiatric disorders. In Multiple Sclerosis (MS cerebellar motor and cognitive dysfunction occur in parallel, early in the onset of the disease, and the cerebellum is one of the predilection sites of atrophy. This study is aimed at determining the relationship between cerebellar volumes, clinical cerebellar signs, cognitive functioning and fatigue in MS. Cerebellar volumetry was conducted using T1-weighted MPRAGE magnetic resonance imaging of 172 MS patients. All patients underwent a clinical and brief neuropsychological assessment (information processing speed, working memory, including fatigue testing. Patients with and without cerebellar signs differed significantly regarding normalized cerebellar total volume (nTCV, normalized brain volume (nBV and whole brain T2 lesion volume (LV. Patients with cerebellar dysfunction likewise performed worse in cognitive tests. A regression analysis indicated that age and nTCV explained 26.3% of the variance in SDMT (symbol digit modalities test performance. However, only age, T2 LV and nBV remained predictors in the full model (r(2 = 0.36. The full model for the prediction of PASAT (Paced Auditory Serial Addition Test scores (r(2 = 0.23 included age, cerebellar and T2 LV. In the case of fatigue, only age and nBV (r(2 = 0.17 emerged as significant predictors. These data support the view that cerebellar abnormalities contribute to disability, including cognitive impairment in MS. However, this contribution does not seem to be independent of, and may even be dominated by wider spread MS pathology as reflected by nBV and T2 LV.

  5. Effect of recovery interventions on cycling performance and pacing strategy in the heat.

    Science.gov (United States)

    De Pauw, Kevin; Roelands, Bart; Vanparijs, Jef; Meeusen, Romain

    2014-03-01

    To determine the effect of active recovery (AR), passive rest (PR), and cold-water immersion (CWI) after 90 min of intensive cycling on a subsequent 12-min time trial (TT2) and the applied pacing strategy in TT2. After a maximal test and familiarization trial, 9 trained male subjects (age 22 ± 3 y, VO2max 62.1 ± 5.3 mL · min-1 · kg-1) performed 3 experimental trials in the heat (30°C). Each trial consisted of 2 exercise tasks separated by 1 h. The first was a 60-min constant-load trial at 55% of the maximal power output followed by a 30-min time trial (TT1). The second comprised a 12-min simulated time trial (TT2). After TT1, AR, PR, or CWI was applied for 15 min. No significant TT2 performance differences were observed, but a 1-sample t test (within each condition) revealed different pacing strategies during TT2. CWI resulted in an even pacing strategy, while AR and PR resulted in a gradual decline of power output after the onset of TT2 (P ≤ .046). During recovery, AR and CWI showed a trend toward faster blood lactate ([BLa]) removal, but during TT2 significantly higher [BLa] was only observed after CWI compared with PR (P = .011). The pacing strategy during subsequent cycling performance in the heat is influenced by the application of different postexercise recovery interventions. Although power was not significantly altered between groups, CWI enabled a differently shaped power profile, likely due to decreased thermal strain.

  6. Identification and function of leucine-rich repeat flightless-I-interacting protein 2 (LRRFIP2 in Litopenaeus vannamei.

    Directory of Open Access Journals (Sweden)

    Shuang Zhang

    Full Text Available Leucine-rich repeat flightless-I-interacting protein 2 (LRRFIP2 is a myeloid differentiation factor 88-interacting protein with a positive regulatory function in toll-like receptor signaling. In this study, seven LRRFIP2 protein variants (LvLRRFIP2A-G were identified in Litopenaeus vannamei. All the seven LvLRRFIP2 protein variants encode proteins with a DUF2051 domain. LvLRRFIP2s were upregulated in hemocytes after challenged with lipopolysaccharide, poly I:C, CpG-ODN2006, Vibrio parahaemolyticus, Staphylococcus aureus, and white spot syndrome virus (WSSV. Dual-luciferase reporter assays in Drosophila Schneider 2 cells revealed that LvLRRFIP2 activates the promoters of Drosophila and shrimp AMP genes. The knockdown of LvLRRFIP2 by RNA interference resulted in higher cumulative mortality of L. vannamei upon V. parahaemolyticus but not S. aureus and WSSV infections. The expression of L. vannamei AMP genes were reduced by dsLvLRRFIP2 interference. These results indicate that LvLRRFIP2 has an important function in antibacterials via the regulation of AMP gene expression.

  7. Running pace decrease during a marathon is positively related to blood markers of muscle damage.

    Directory of Open Access Journals (Sweden)

    Juan Del Coso

    Full Text Available BACKGROUND: Completing a marathon is one of the most challenging sports activities, yet the source of running fatigue during this event is not completely understood. The aim of this investigation was to determine the cause(s of running fatigue during a marathon in warm weather. METHODOLOGY/PRINCIPAL FINDINGS: We recruited 40 amateur runners (34 men and 6 women for the study. Before the race, body core temperature, body mass, leg muscle power output during a countermovement jump, and blood samples were obtained. During the marathon (27 °C; 27% relative humidity running fatigue was measured as the pace reduction from the first 5-km to the end of the race. Within 3 min after the marathon, the same pre-exercise variables were obtained. RESULTS: Marathoners reduced their running pace from 3.5 ± 0.4 m/s after 5-km to 2.9 ± 0.6 m/s at the end of the race (P 15% pace reduction had elevated post-race myoglobin (1318 ± 1411 v 623 ± 391 µg L(-1; P<0.05, lactate dehydrogenase (687 ± 151 v 583 ± 117 U L(-1; P<0.05, and creatine kinase (564 ± 469 v 363 ± 158 U L(-1; P = 0.07 in comparison with marathoners that preserved their running pace reasonably well throughout the race. However, they did not differ in their body mass change (-3.1 ± 1.0 v -3.0 ± 1.0%; P = 0.60 or post-race body temperature (38.7 ± 0.7 v 38.9 ± 0.9 °C; P = 0.35. CONCLUSIONS/SIGNIFICANCE: Running pace decline during a marathon was positively related with muscle breakdown blood markers. To elucidate if muscle damage during a marathon is related to mechanistic or metabolic factors requires further investigation.

  8. DiPALS: Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis - a randomised controlled trial.

    Science.gov (United States)

    McDermott, Christopher J; Bradburn, Mike J; Maguire, Chin; Cooper, Cindy L; Baird, Wendy O; Baxter, Susan K; Cohen, Judith; Cantrill, Hannah; Dixon, Simon; Ackroyd, Roger; Baudouin, Simon; Bentley, Andrew; Berrisford, Richard; Bianchi, Stephen; Bourke, Stephen C; Darlison, Roy; Ealing, John; Elliott, Mark; Fitzgerald, Patrick; Galloway, Simon; Hamdalla, Hisham; Hanemann, C Oliver; Hughes, Philip; Imam, Ibrahim; Karat, Dayalan; Leek, Roger; Maynard, Nick; Orrell, Richard W; Sarela, Abeezar; Stradling, John; Talbot, Kevin; Taylor, Lyn; Turner, Martin; Simonds, Anita K; Williams, Tim; Wedzicha, Wisia; Young, Carolyn; Shaw, Pamela J

    2016-06-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease resulting in death, usually from respiratory failure, within 2-3 years of symptom onset. Non-invasive ventilation (NIV) is a treatment that when given to patients in respiratory failure leads to improved survival and quality of life. Diaphragm pacing (DP), using the NeuRx/4(®) diaphragm pacing system (DPS)™ (Synapse Biomedical, Oberlin, OH, USA), is a new technique that may offer additional or alternative benefits to patients with ALS who are in respiratory failure. The Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis (DiPALS) trial evaluated the effect of DP on survival over the study duration in patients with ALS with respiratory failure. The DiPALS trial was a multicentre, parallel-group, open-label, randomised controlled trial incorporating health economic analyses and a qualitative longitudinal substudy. Eligible participants had a diagnosis of ALS (ALS laboratory-supported probable, clinically probable or clinically definite according to the World Federation of Neurology revised El Escorial criteria), had been stabilised on riluzole for 30 days, were aged ≥ 18 years and were in respiratory failure. We planned to recruit 108 patients from seven UK-based specialist ALS or respiratory centres. Allocation was performed using 1 : 1 non-deterministic minimisation. Participants were randomised to either standard care (NIV alone) or standard care (NIV) plus DP using the NeuRX/4 DPS. The primary outcome was overall survival, defined as the time from randomisation to death from any cause. Secondary outcomes were patient quality of life [assessed by European Quality of Life-5 Dimensions, three levels (EQ-5D-3L), Short Form questionnaire-36 items and Sleep Apnoea Quality of Life Index questionnaire]; carer quality of life (EQ-5D-3L and Caregiver Burden Inventory); cost-utility analysis and health-care resource use; tolerability and adverse events. Acceptability and attitudes to

  9. A hybrid NIRS-EEG system for self-paced brain computer interface with online motor imagery.

    Science.gov (United States)

    Koo, Bonkon; Lee, Hwan-Gon; Nam, Yunjun; Kang, Hyohyeong; Koh, Chin Su; Shin, Hyung-Cheul; Choi, Seungjin

    2015-04-15

    For a self-paced motor imagery based brain-computer interface (BCI), the system should be able to recognize the occurrence of a motor imagery, as well as the type of the motor imagery. However, because of the difficulty of detecting the occurrence of a motor imagery, general motor imagery based BCI studies have been focusing on the cued motor imagery paradigm. In this paper, we present a novel hybrid BCI system that uses near infrared spectroscopy (NIRS) and electroencephalography (EEG) systems together to achieve online self-paced motor imagery based BCI. We designed a unique sensor frame that records NIRS and EEG simultaneously for the realization of our system. Based on this hybrid system, we proposed a novel analysis method that detects the occurrence of a motor imagery with the NIRS system, and classifies its type with the EEG system. An online experiment demonstrated that our hybrid system had a true positive rate of about 88%, a false positive rate of 7% with an average response time of 10.36 s. As far as we know, there is no report that explored hemodynamic brain switch for self-paced motor imagery based BCI with hybrid EEG and NIRS system. From our experimental results, our hybrid system showed enough reliability for using in a practical self-paced motor imagery based BCI. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.

    Science.gov (United States)

    Kang, Alex H; Johnson, Glen H; Lepe, Xavier; Wataha, John C

    2009-05-01

    A common technique used for making crown impressions involves use of a vinyl polysiloxane impression material in combination with a dual-arch tray. A leading dental manufacturer has reformulated its vinyl polysiloxane (VPS) impression line, but the accuracy of the new material has not been verified. The purpose of this study was to assess the accuracy of reformulated VPS impression materials using the single-step dual-arch impression technique. Dual-arch impressions were made on a typodont containing a master stainless steel standard crown preparation die, from which gypsum working dies were formed, recovered, and measured. The impression materials evaluated were Imprint 3 Penta Putty with Quick Step Regular Body (IP-0); Imprint 3 Penta Quick Step Heavy Body with Quick Step Light Body (IP-1); Aquasil Ultra Rigid Fast Set with LV Fast Set (AQ-1); and Aquasil Ultra Heavy Fast Set with XLV Fast Set (AQ-2) (n=10). All impressions were disinfected with CaviCide spray for 10 minutes prior to pouring with type IV gypsum. Buccolingual (BL), mesiodistal (MD), and occlusogingival (OG) dimensions were measured and compared to the master die using an optical measuring microscope. Linear dimensional change was also assessed for IP-0 and AQ-1 at 1 and 24 hours based on ANSI/ADA Specification No. 19. Single-factor ANOVA with Dunnett's T3 multiple comparisons was used to compare BL, MD, and OG changes, with hypothesis testing at alpha=.05. A repeated-measures ANOVA was used to compare linear dimensional changes. There were statistical differences among the 4 impression systems for 3 of 4 dimensions of the master die. IP-0 working dies were significantly larger in MD and OG-L dimensions but significantly smaller in the BL dimension. IP-1 working dies were significantly smaller in the BL dimension compared to the master die. With the exception of IP-0, differences detected were small and clinically insignificant. No significant differences were observed for linear dimensional change

  11. Application of radionuclide ventriculography phase analysis in patients with atrial or ventricular pacing for detecting ventricular abnormal excitation

    International Nuclear Information System (INIS)

    Shi Rongfang; Wang Zhonggan; Li Shengting

    1996-01-01

    The aim of the study was to increase the accuracy of detecting ventricular abnormal excitation. During atrial or ventricular pacing, radionuclide ventriculography phase analysis (RNV-PA) was performed in 17 patients with Wolff-Parkinson-White (W-P-W) syndrome and paroxysmal supra ventricular tachycardia (PSVT) and ventricular tachycardia (PVT). During pacing, detection rate of abnormal excitation by RNV-PA was 95.5%, compared with 68.2% during basic conduction. Atrial or ventricular pacing can significantly increase the detection rate of abnormal excitation by RNV-PA in patients with W-P-W syndrome. It may be a valuable method for identifying the abnormal excitation and estimating the therapeutic effect of ablation

  12. Sound Effects for Children's Comprehension of Variably-Paced Television Programs.

    Science.gov (United States)

    Calvert, Sandra L.; Scott, M. Catherine

    In this study, children's selective attention to, and comprehension of, variably-paced television programs were examined as a function of sound effects. Sixty-four children, equally distributed by sex and by preschool and fourth grades, were randomly assigned to one of four treatment conditions which crossed two levels of sound effects (presence…

  13. Different horse's paces during hippotherapy on spatio-temporal parameters of gait in children with bilateral spastic cerebral palsy: A feasibility study.

    Science.gov (United States)

    Antunes, Fabiane Nunes; Pinho, Alexandre Severo do; Kleiner, Ana Francisca Rozin; Salazar, Ana Paula; Eltz, Giovana Duarte; de Oliveira Junior, Alcyr Alves; Cechetti, Fernanda; Galli, Manuela; Pagnussat, Aline Souza

    2016-12-01

    Hippotherapy is often carried out for the rehabilitation of children with Cerebral Palsy (CP), with the horse riding at a walking pace. This study aimed to explore the immediate effects of a hippotherapy protocol using a walk-trot pace on spatio-temporal gait parameters and muscle tone in children with Bilateral Spastic CP (BS-CP). Ten children diagnosed with BS-CP and 10 healthy aged-matched children (reference group) took part in this study. The children with BS-CP underwent two sessions of hippotherapy for one week of washout between them. Two protocols (lasting 30min) were applied on separate days: Protocol 1: the horse's pace was a walking pace; and Protocol 2: the horse's pace was a walk-trot pace. Children from the reference group were not subjected to treatment. A wireless inertial measurement unit measured gait spatio-temporal parameters before and after each session. The Modified Ashworth Scale was applied for muscle tone measurement of hip adductors. The participants underwent the gait assessment on a path with surface irregularities (ecological context). The comparisons between BS-CP and the reference group found differences in all spatio-temporal parameters, except for gait velocity. Within-group analysis of children with BS-CP showed that the swing phase did not change after the walk pace and after the walk-trot pace. The percentage of rolling phase and double support improved after the walk-trot. The spasticity of the hip adductors was significantly reduced as an immediate result of both protocols, but this decrease was more evident after the walk-trot. The walk-trot protocol is feasible and is able to induce an immediate effect that improves the gait spatio-temporal parameters and the hip adductors spasticity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.

    Science.gov (United States)

    Shepherd, Emma; Stuart, Graham; Martin, Rob; Walsh, Mark A

    2015-06-01

    SelectSecure™ pacing leads (Medtronic Inc) are increasingly being used in pediatric patients and adults with structural congenital heart disease. The 4Fr lead is ideal for patients who may require lifelong pacing and can be advantageous for patients with complex anatomy. The purpose of this study was to compare the extraction of SelectSecure leads with conventional (stylette-driven) pacing leads in patients with structural congenital heart disease and congenital atrioventricular block. The data on lead extractions from pediatric and adult congenital heart disease (ACHD) patients from August 2004 to July 2014 at Bristol Royal Hospital for Children and the Bristol Heart Institute were reviewed. Multivariable regression analysis was used to determine whether conventional pacing leads were associated with a more difficult extraction process. A total of 57 patients underwent pacemaker lead extractions (22 SelectSecure, 35 conventional). No deaths occurred. Mean age at the time of extraction was 17.6 ± 10.5 years, mean weight was 47 ± 18 kg, and mean lead age was 5.6 ± 2.6 years (range 1-11 years). Complex extraction (partial extraction/femoral extraction) was more common in patients with conventional pacing leads at univariate (P < .01) and multivariate (P = .04) levels. Lead age was also a significant predictor of complex extraction (P < .01). SelectSecure leads can be successfully extracted using techniques that are used for conventional pacing leads. They are less likely to be partially extracted and are less likely to require extraction using a femoral approach compared with conventional pacing leads. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Investigating the Effects of Concurrent Performance of Physical and Cognitive Demanding Task in Paced Assembly Lines

    Directory of Open Access Journals (Sweden)

    Shakil Ahmed Shaikh

    2013-07-01

    Full Text Available The study was undertaken to investigate the effects of pacing on aspects of performance at an assembly task and on the operators' responses related to work behaviour, perceived workload and perceived stress. A particular objective of the study was to investigate whether physical and cognitive demands may interact in their influences on these effects. An assembly task was simulated in the laboratory and the level of pacing imposed, work height and memory load within the task were all varied. The results showed that the type of pacing commonly imposed (as is common with a lean manufacturing Takt time system in industry can significantly affect both performance and perceived workload and stress. Physical demands (through work height affecting posture and mental demand (through memory load were also found to have significant effects, as would be expected from the many studies of these in the literature. More importantly, some interactions were found between pacing and work height in their effects on quality of assembly and the operator's own rating of performance, and between work height and memory load in their effects on errors. These findings will need to be taken into account by companies when implementing Takt time systems.

  16. A projection-adapted cross entropy (PACE) method for transmission network planning

    Energy Technology Data Exchange (ETDEWEB)

    Eshragh, Ali; Filar, Jerzy [University of South Australia, School of Mathematics and Statistics, Mawson Lakes, SA (Australia); Nazar, Asef [University of South Australia, Institute for Sustainable Systems Technologies, School of Mathematics and Statistics, Mawson Lakes, SA (Australia)

    2011-06-15

    In this paper, we propose an adaptation of the cross entropy (CE) method called projection-adapted CE (PACE) to solve a transmission expansion problem that arises in management of national and provincial electricity grids. The aim of the problem is to find an expansion policy that is both economical and operational from the technical perspective. Often, the transmission network expansion problem is mathematically formulated as a mixed integer nonlinear program that is very challenging algorithmically. The challenge originates from the fact that a global optimum should be found despite the presence, of possibly a huge number, of local optima. The PACE method shows promise in solving global optimization problems regardless of continuity or other assumptions. In our approach, we sample the integer variables using the CE mechanism, and solve LPs to obtain matching continuous variables. Numerical results, on selected test systems, demonstrate the potential of this approach. (orig.)

  17. Towards Development of a 3-State Self-Paced Brain-Computer Interface

    Directory of Open Access Journals (Sweden)

    Ali Bashashati

    2007-01-01

    the presence of a right- or a left-hand movement and the second classifies the detected movement as a right or a left one. In an offline analysis of the EEG data collected from four able-bodied individuals, the 3-state brain-computer interface shows a comparable performance with a 2-state system and significant performance improvement if used as a 2-state BCI, that is, in detecting the presence of a right- or a left-hand movement (regardless of the type of movement. It has an average true positive rate of 37.5% and 42.8% (at false positives rate of 1% in detecting right- and left-hand extensions, respectively, in the context of a 3-state self-paced BCI and average detection rate of 58.1% (at false positive rate of 1% in the context of a 2-state self-paced BCI.

  18. Presence of Tube isoforms in Litopenaeus vannamei suggests various regulatory patterns of signal transduction in invertebrate NF-κB pathway.

    Science.gov (United States)

    Li, Chaozheng; Chen, Yixiao; Weng, Shaoping; Li, Sedong; Zuo, Hongliang; Yu, Xiaoqiang; Li, Haoyang; He, Jianguo; Xu, Xiaopeng

    2014-02-01

    The toll-like receptor (TLR)/NF-κB signaling pathways play critical roles in the innate immune system. The intracellular signal transduction of most TLR pathways in invertebrate cells is triggered by formation of a heterotrimeric complex composed of MyD88, Tube and Pelle. In this study, we identified a Litopenaeus vannamei Pelle (LvPelle) and an isoform of L. vannamei Tube (LvTube) designated as LvTube-1. The interactions among LvPelle, LvTube/LvTube-1 and LvMyD88/LvMyD88-1 were elucidated and their functions during pathogen infections were investigated. Knockdowns of LvPelle and LvTube/LvTube-1 using RNAi strategy led to higher mortalities of shrimps during Vibrio parahemolyticus infection, and could reduce the genome copy number of white spot syndrome virus (WSSV) in the infected muscle tissue but did not affect the mortality caused by WSSV infection. The effects of LvPelle and LvTube/LvTube-1 on promoters containing NF-κB binding motifs were analyzed by dual-luciferase reporter assays and the results demonstrated that LvTube-1 could activate the NF-κB activity to significantly higher level than LvTube did. Moreover, tissue distributions of LvTube and LvTube-1 mRNAs and their expression profiles during pathogen and immune stimulant challenges were different, indicating that they could play different roles in immune responses. This is the first report of Tube isoforms in invertebrates. Together with our previous study on LvMyD88 isoforms, our results suggest that various isoforms of adaptor components may be involved in various regulatory patterns of signal transduction in invertebrate TLR/NF-κB pathway and this could be a strategy adopted by invertebrates to modulate immune responses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. The impact of the perception of rhythmic music on self-paced oscillatory movements.

    Science.gov (United States)

    Peckel, Mathieu; Pozzo, Thierry; Bigand, Emmanuel

    2014-01-01

    Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping) while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20 s before a 2 s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced) while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with the task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e., motor/perceptual resonance). In general, our results give support to the notion that rhythmic music is processed in a motoric

  20. The impact of the perception of rhythmic music on oscillatory self-paced movements

    Directory of Open Access Journals (Sweden)

    Mathieu ePeckel

    2014-09-01

    Full Text Available Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20s before a 2s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e. motor/perceptual resonance. In general, our results give support to the notion that rhythmic music is processed in a