WorldWideScience

Sample records for dual-site lv pacing

  1. Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents.

    Science.gov (United States)

    O'Donnell, David; Sperzel, Johannes; Thibault, Bernard; Rinaldi, Christopher A; Pappone, Carlo; Gutleben, Klaus-Jürgen; Leclercq, Christopher; Razavi, Hedi; Ryu, Kyungmoo; Mcspadden, Luke C; Fischer, Avi; Tomassoni, Gery

    2017-04-01

    The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  2. Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization.

    Science.gov (United States)

    Pappone, C; Rosanio, S; Oreto, G; Tocchi, M; Gulletta, S; Salvati, A; Dicandia, C; Santinelli, V; Mazzone, P; Veglia, F; Ding, J; Sallusti, L; Spinelli, J; Vicedomini, G

    2000-07-01

    Acute left ventricular pacing has been associated with hemodynamic improvement in patients with congestive heart failure and wide QRS complex. We hypothesized that pacing two left ventricular sites simultaneously would produce faster activation and better systolic function than single-site pacing. We selected 14 heart failure patients (NYHA functional class III or IV) in normal sinus rhythm with left bundle branch block and QRS > 150 ms. An 8F dual micromanometer catheter was placed in the aorta for measuring +dP/dt (mmHg/s), aortic pulse pressure (mmHg), and end-diastolic pressure (mmHg). Pacing leads were positioned via coronary veins at the posterior base and lateral wall. Patients were acutely paced VDD at the posterior base, lateral wall, and both sites (dual-site) with 5 atrioventricular delays (from 8 ms to PR -30 ms). Pacing sequences were executed in randomized order using a custom external computer (FlexStim, Guidant CRM). Dual-site pacing increased peak +dP/dt significantly more than posterior base and lateral wall pacing. Dual-site and posterior base pacing raised aortic pulse pressure significantly more than lateral wall pacing. Dual-site pacing shortened QRS duration by 22 %, whereas posterior base and lateral wall pacing increased it by 2 and 12%, respectively (p = 0.006). In heart failure patients with left bundle branch block, dual-site pacing improves systolic function more than single-site stimulation. Improved ventricular activation synchrony, expressed by paced QRS narrowing, may account for the additional benefit of dual- vs single-site pacing in enhancing contractility. This novel approach deserves consideration for future heart failure pacing studies.

  3. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  4. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  5. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  6. Temporary pacing

    Directory of Open Access Journals (Sweden)

    L.J. Workman

    1983-09-01

    Full Text Available Artificial cardiac pacing, the use of electrical stimuli to cause contraction of heart muscle, is a sophisticated therapeutic and diagnostic tool. Its rapid technologic improvement since first developed in the late 1930’s by Hyman, has made it possible not only to avoid certain cases of death due to heart block, but also to extend and improve the quality of life. Pacemaker therapy is generally used to treat heart rate or rhythm disturbances, being either tachy- or bradyarrhythmias that produce a detrimental drop in cardiac output. Of the many different types of pacemakers and electrodes currently available, ventricular demand pacing is the most commonly used.

  7. The effect of right ventricular pacing on myocardial oxidative metabolism and efficiency: relation with left ventricular dyssynchrony

    Energy Technology Data Exchange (ETDEWEB)

    Ukkonen, Heikki; Saraste, Antti; Koistinen, Juhani [Turku University Hospital, Department of Medicine, P.O. Box 52, Turku (Finland); Tops, Laurens; Bax, Jeroen [Leiden University Medical Center, Leiden (Netherlands); Naum, Alexander [University of Turku, Turku PET Centre, Turku (Finland); Knuuti, Juhani [University of Turku, Turku PET Centre, Turku (Finland); Turku University Hospital, Turku PET Centre, P.O. Box 52, Turku (Finland)

    2009-12-15

    Right ventricular (RV) apical pacing induces dyssynchrony by a left bundle branch block type electrical activation sequence in the heart and may impair left ventricular (LV) function. Whether these functional changes are accompanied by changes in myocardial perfusion, oxidative metabolism and efficiency, and the relation with the induction of LV dyssynchrony are unknown. Our study was designed to investigate the acute effects of RV pacing on these parameters. Ten patients with normal LV ejection fraction and VVI/DDD pacemaker were studied during AAI pacing/sinus rhythm without RV pacing (pacing-OFF) and with RV pacing (pacing-ON) at the same heart rate. Dynamic [{sup 15}O]water and [{sup 11}C]acetate positron emission tomography was used to measure perfusion and oxidative metabolism (k{sub mono}) of the LV. An echocardiographic examination was used to assess LV stroke volume (SV) and LV dyssynchrony. Myocardial efficiency of forward work was calculated as systolic blood pressure x cardiac output/LV mass/k{sub mono}. RV pacing decreased SV in all subjects (mean decrease 13%, from 76 {+-} 7 to 66 {+-} 7 ml, p = 0.004), but global perfusion and k{sub mono} were unchanged. The efficiency tended to be lower with pacing-ON (70 {+-} 20 vs 81 {+-} 21 mmHg l/g, p = 0.066). In patients with dyssynchrony during pacing (n = 6) efficiency decreased by 23% (from 78 {+-} 25 to 60 {+-} 14 mmHg l/g, p = 0.02), but in patients without dyssynchrony no change in efficiency was detected. Accordingly, heterogeneity in myocardial perfusion and oxidative metabolism was detected during pacing in patients with dyssynchrony but not in those without dyssynchrony. RV pacing resulted in a significant decrease in SV. However, deleterious effects on LV oxidative metabolism and efficiency were observed only in patients with dyssynchrony during RV pacing. (orig.)

  8. Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

    Science.gov (United States)

    Gillis, Anne M

    2014-10-01

    The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.

  9. New method for cardiac resynchronization therapy: Transapical endocardial lead implantation for left ventricular free wall pacing

    NARCIS (Netherlands)

    I. Kassai (Imre); C. Foldesi (Csaba); A. Szekely (Andrea); T. Szili-Torok (Tamas)

    2008-01-01

    textabstractCoronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a significant dislocation rate during follow-up. For these patients, epicardial pacing lead implantation is the most

  10. L.V. switchgear - design and development

    International Nuclear Information System (INIS)

    Armes, D.S.; Brown, R.D.

    1992-01-01

    This work describes the methods employed in the design and development of L.V. switchgear to meet the prospective conditions and operational requirements imposed on equipment at sites of PWR power stations. The work concentrates on the aspects of design, manufacture, qualification work and quality assurance particular to the range of L.V. switchgear distribution boards manufactured by Laurence, Scott and Electromotors Ltd. for Sizewell B Power Station and contrasts this equipment with other equipment for conventional (i.e. non-nuclear) power station purposes. (Author)

  11. Right heart failure due to loss of right ventricular capture in a patient with atrioventricular junction ablation and biventricular pacing.

    Science.gov (United States)

    Raffa, Santi; Fantoni, Cecilia; Restauri, Luigia; Auricchio, Angelo

    2005-10-01

    We describe the case of a patient with atrioventricular (AV) junction ablation and chronic biventricular pacing in which intermittent dysfunction of the right ventricular (RV) lead resulted in left ventricular (LV) stimulation alone and onset of severe right heart failure. Restoration of biventricular pacing by increasing device output and then performing lead revision resolved the issue. This case provides evidence that LV pacing alone in patients with AV junction ablation may lead to severe right heart failure, most likely as a result of iatrogenic mechanical dyssynchrony within the RV. Thus, probably this pacing mode should be avoided in pacemaker-dependent patients with heart failure.

  12. Protection of LV system against lightning

    OpenAIRE

    Yordanova Nedyalkova, Greta

    2010-01-01

    Lightning is a natural hazard and one of the greatest local mysteries. Scientists have not fully understood the mechanism of lightning. It is one of the most beautiful displays in nature and one of the nature's most dangerous phenomenon known to man. Overvoltage due to lightning is a very important problem of LV systems. Some lightning flashes damage buildings and a few kill or injure people and animals, either directly or indirectly, by causing fire and explosions. The need for protect...

  13. Broadening of molecular weight distribution of polymers synthesized by metallocene-based dual-site catalysts; Alargamento da distribuicao de massa molar de polimeros sintetizados com catalisadores metalocenicos dual-site

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joao H.Z. dos [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Inst. de Quimica]. E-mail: jhzds@iq.ufrgs.br; Fisch, Adriano G.; Cardozo, Nilo S.M.; Secchi, Argimiro R. [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Dept. de Engenharia Quimica

    2008-07-01

    The main topics related to the use of dual-site catalysts in the production of polymers with broad molecular weight distribution are reviewed. The polymerization using dual-site catalysts is more economical and allows to produce a higher quality product than other processes, such as polymer blend and multistage reactors. However, the formulation of these catalysts is quite complicated since the same catalyst must produce distinct polymer grades. In addition, the release of patents concerning the combination of metallocenes and new technologies for polymerization shows that polymerization processes using dual-site catalysts are of current industrial interest. (author)

  14. Tilapia lake virus (TiLV): Literature review

    OpenAIRE

    Jansen, Mona Dverdal; Mohan, Chadag Vishnumurthy

    2017-01-01

    Tilapia lake virus (TiLV) is an emerging infectious agent that has recently been identified in diseased tilapia on three continents. At the time of writing, scientific publications have reported TiLV in samples collected from Colombia, Ecuador, Egypt, Israel and Thailand. While the link between TiLV and disease outbreaks in Israel and Thailand are well documented, further investigations are being undertaken to determine the significance of TiLV in the other countries. Israel and Taiwan Provin...

  15. Biventricular / Left Ventricular Pacing in Hypertrophic Obstructive Cardiomyopathy: An Overview

    Directory of Open Access Journals (Sweden)

    Radu Vatasescu, MD

    2012-05-01

    Full Text Available Hypertrophic cardiomyopathy (HCM is an autosomal dominant inherited genetic disease characterized by compensatory pathological left ventricle (LV hypertrophy due to sarcomere dysfunction. In an important proportion of patients with HCM, the site and extent of cardiac hypertrophy results in severe obstruction to LV outflow tract (LVOT, contributing to disabling symptoms and increasing the risk of sudden cardiac death (SCD. In patients with progressive and/or refractory symptoms despite optimal pharmacological treatment, invasive therapies that diminish or abolish LVOT obstruction relieve heart failure-related symptoms, improve quality of life and could be associated with long-term survival similar to that observed in the general population. The gold standard in this respect is surgical septal myectomy, which might be supplementary associated with a reduction in SCD. Percutaneous techniques, particularly alcohol septal ablation (ASA and more recently radiofrequency (RF septal ablation, can achieve LVOT gradient reduction and symptomatic benefit in a large proportion of HOCM patients at the cost of a supposedly limited septal myocardial necrosis and a 10-20% risk of chronic atrioventricular block. After an initial period of enthusiasm, standard DDD pacing failed to show in randomized trials significant LVOT gradient reductions and objective improvement in exercise capacity. However, case reports and recent small pilot studies suggested that atrial synchronous LV or biventricular (biV pacing significantly reduce LVOT obstruction and improve symptoms (acutely as well as long-term in a large proportion of severely symptomatic HOCM patients not suitable to other gradient reduction therapies. Moreover, biV/LV pacing in HOCM seems to be associated with significant LV reverse remodelling.

  16. Estimation of the effects of multipoint pacing on battery longevity in routine clinical practice.

    Science.gov (United States)

    Akerström, Finn; Narváez, Irene; Puchol, Alberto; Pachón, Marta; Martín-Sierra, Cristina; Rodríguez-Mañero, Moisés; Rodríguez-Padial, Luis; Arias, Miguel A

    2017-09-23

    Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  17. [Influence of pacing site on myocardial transmural dispersion of repolarization in intact normal and dilated cardiomyopathy dogs].

    Science.gov (United States)

    Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin

    2003-12-25

    In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged

  18. Pacing stress echocardiography

    Directory of Open Access Journals (Sweden)

    Agrusta Marco

    2005-12-01

    Full Text Available Abstract Background High-rate pacing is a valid stress test to be used in conjunction with echocardiography; it is independent of physical exercise and does not require drug administration. There are two main applications of pacing stress in the echo lab: the noninvasive detection of coronary artery disease through induction of a regional transient dysfunction; and the assessment of contractile reserve through peak systolic pressure/ end-systolic volume relationship at increasing heart rates to assess global left ventricular contractility. Methods The pathophysiologic rationale of pacing stress for noninvasive detection of coronary artery disease is obvious, with the stress determined by a controlled increase in heart rate, which is a major determinant of myocardial oxygen demand, and thereby tachycardia may exceed a fixed coronary flow reserve in the presence of hemodynamically significant coronary artery disease. The use of pacing stress echo to assess left ventricular contractile reserve is less established, but promising. Positive inotropic interventions are mirrored by smaller end-systolic volumes and higher end-systolic pressures. An increased heart rate progressively increases the force of ventricular contraction (Bowditch treppe or staircase phenomenon. To build the force-frequency relationship, the force is determined at different heart rate steps as the ratio of the systolic pressure (cuff sphygmomanometer/end-systolic volume index (biplane Simpson rule. The heart rate is determined from ECG. Conclusion Two-dimensional echocardiography during pacing is a useful tool in the detection of coronary artery disease. Because of its safety and ease of repeatability noninvasive pacing stress echo can be the first-line stress test in patients with permanent pacemaker. The force-frequency can be defined as up- sloping (normal when the peak stress pacing systolic pressure/end-systolic volume index is higher than baseline and intermediate stress

  19. PACE Status Update

    Energy Technology Data Exchange (ETDEWEB)

    M., Zimring,; Hoffman, I.; Fuller, M.

    2010-08-11

    The Federal Housing Finance Agency (FHFA) regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On July 6, 2010, FHFA and the Office of the Comptroller of the Currency (OCC) concluded that Property Assessed Clean Energy (PACE) programs 'present significant safety and soundness concerns' to the housing finance industry. This statement came after a year of discussions with state and federal agencies in which PACE, a novel mechanism for financing energy efficiency and renewable energy improvements, has gone from receiving support from the White House, canonization as one of Scientific American's 'World Changing Ideas' and legislative adoption in 24 states to questionable relevance, at least in the residential sector. Whether PACE resumes its expansion as an innovative tool for financing energy efficiency and clean generation depends on outcomes in each of the three branches of government - discussions on a PACE pilot phase among federal agencies, litigation in federal court, and legislation in Congress - all highly uncertain. This policy brief addresses the practical impacts of these possible outcomes on existing and emerging PACE programs across the United States and potential paths forward.

  20. Long pacing pulses reduce phrenic nerve stimulation in left ventricular pacing.

    Science.gov (United States)

    Hjortshøj, Søren; Heath, Finn; Haugland, Morten; Eschen, Ole; Thøgersen, Anna Margrethe; Riahi, Sam; Toft, Egon; Struijk, Johannes Jan

    2014-05-01

    Phrenic nerve stimulation is a major obstacle in cardiac resynchronization therapy (CRT). Activation characteristics of the heart and phrenic nerve are different with higher chronaxie for the heart. Therefore, longer pulse durations could be beneficial in preventing phrenic nerve stimulation during CRT due to a decreased threshold for the heart compared with the phrenic nerve. We investigated if long pulse durations decreased left ventricular (LV) thresholds relatively to phrenic nerve thresholds in humans. Eleven patients, with indication for CRT and phrenic nerve stimulation at the intended pacing site, underwent determination of thresholds for the heart and phrenic nerve at different pulse durations (0.3-2.9 milliseconds). The resulting strength duration curves were analyzed by determining chronaxie and rheobase. Comparisons for those parameters were made between the heart and phrenic nerve, and between the models of Weiss and Lapicque as well. In 9 of 11 cases, the thresholds decreased faster for the LV than for the phrenic nerve with increasing pulse duration. In 3 cases, the thresholds changed from unfavorable for LV stimulation to more than a factor 2 in favor of the LV. The greatest change occurred for pulse durations up to 1.5 milliseconds. The chronaxie of the heart was significantly higher than the chronaxie of the phrenic nerve (0.47 milliseconds vs. 0.22 milliseconds [P = 0.029, Lapicque] and 0.79 milliseconds vs. 0.27 milliseconds [P = 0.033, Weiss]). Long pulse durations lead to a decreased threshold of the heart relatively to the phrenic nerve and may prevent stimulation of the phrenic nerve in a clinical setting. © 2013 Wiley Periodicals, Inc.

  1. Molecular Level Control Through Dual Site Participation Using Bimetallic Catalysts - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    d' Itri, Julie, L.; Kovalchuk, Vladimir, I.

    2010-02-08

    The overall goal of this research program was to explore the hypothesis that it is possible to design a bimetallic surface such that each metal catalyzes different elementary reaction steps in an overall reaction pathway. A corollary to this hypothesis is that the different ensemble size requirements for an elementary reaction step can be used to force an elementary reaction step to occur on only one of the metals. The research program involved a combination of materials synthesis, chemical kinetics experiments, spectroscopic studies and computational investigations. The major outcome of this research program was the development and dissemination of the Dual Site Model, for which chlorocarbon reactions in the presence of hydrogen were used as model systems.

  2. Expanding the Substrate Specificity of Thermoanaerobacter pseudoethanolicus Secondary Alcohol Dehydrogenase by a Dual Site Mutation

    KAUST Repository

    Musa, Musa M.; Bsharat, Odey; Karume, Ibrahim; Vieille, Claire; Takahashi, Masateru; Hamdan, Samir

    2017-01-01

    Here, we report the asymmetric reduction of selected phenyl-ring-containing ketones by various single and dual site mutants of Thermoanaerobacter pseudoethanolicus secondary alcohol dehydrogenase (TeSADH). Further expanding the size of the substrate binding pocket in the mutant W110A/I86A not only allowed substrates of the single mutants W110A and I86A to be accommodated within the expanded active site, but also expanded the enzyme's substrate range to ketones bearing two sterically demanding groups (bulky-bulky ketones), which are not substrates for TeSADH single mutants. We also report the regio- and enantioselective reduction of diketones using W110A/I86A TeSADH and single TeSADH mutants. The double mutant exhibited dual stereopreference generating the Prelog products most of the time and the anti-Prelog products in a few cases.

  3. Expanding the Substrate Specificity of Thermoanaerobacter pseudoethanolicus Secondary Alcohol Dehydrogenase by a Dual Site Mutation

    KAUST Repository

    Musa, Musa M.

    2017-12-14

    Here, we report the asymmetric reduction of selected phenyl-ring-containing ketones by various single and dual site mutants of Thermoanaerobacter pseudoethanolicus secondary alcohol dehydrogenase (TeSADH). Further expanding the size of the substrate binding pocket in the mutant W110A/I86A not only allowed substrates of the single mutants W110A and I86A to be accommodated within the expanded active site, but also expanded the enzyme\\'s substrate range to ketones bearing two sterically demanding groups (bulky-bulky ketones), which are not substrates for TeSADH single mutants. We also report the regio- and enantioselective reduction of diketones using W110A/I86A TeSADH and single TeSADH mutants. The double mutant exhibited dual stereopreference generating the Prelog products most of the time and the anti-Prelog products in a few cases.

  4. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Sequential biventricular pacing improves regional contractility, longitudinal function and dyssynchrony in patients with heart failure and prolonged QRS

    Directory of Open Access Journals (Sweden)

    Ring Margareta

    2010-04-01

    Full Text Available Abstract Aims Biventricular pacing (BiP is an effective treatment in systolic heart failure (HF patients with prolonged QRS. However, approximately 35% of the patients receiving BiP are classified as non-responders. The aim of this study is to evaluate the acute effects of VV-optimization on systolic heart function. Methods Twenty-one HF patients aged 72 (46-88 years, QRS 154 (120-190 ms, were studied with echocardiography, Tissue Doppler Imaging (TDI and 3D-echo the first day after receiving a BiP device. TDI was performed; during simultaneous pacing (LV-lead pacing 4 ms before the RV-lead and during sequential pacing (LV 20 and 40 ms before RV and RV 20 and 40 ms before LV-lead pacing. Systolic heart function was studied by tissue tracking (TT for longitudinal function and systolic maximal velocity (SMV for regional contractility and signs of dyssynchrony assessed by time-delays standard deviation of aortic valve opening to SMV, AVO-SMV/SD and tissue synchronization imaging (TSI. Results The TT mean value preoperatively was 4,2 ± 1,5 and increased at simultaneous pacing to 5,0 ± 1,2 mm (p Conclusions VV-optimization in the acute phase improves systolic heart function more than simultaneous BiP pacing. Long-term effects should be evaluated in prospective randomized trials.

  6. The influence of right ventricular apical pacing on left atrial volume in patients with normal left ventricular function

    Directory of Open Access Journals (Sweden)

    AR Moaref1

    2008-03-01

    Full Text Available Background: Right ventricular apical (RVA pacing has been reported to induce several deleterious effects particularly in the presence of structural heart disease but can also involve patients with normal left ventricular (LV function. Left atrial (LA enlargement is one of these effects, but the majority of studies have measured LA dimension rather than volume.Objective: The present prospective study was designed to assess the effect of RVA pacing on LA volume in patients with normal LV function.Patients and Methods: The study comprised 41 consecutive patients with LV ejection fraction ≥ 45% and LV end diastolic dimension ≤ 56 mm who underwent single-or dual- chamber pacemaker implantation in RVA and followed for LA volume measurement and pacemaker analysis at least during the ensuing 4.2 months. Results: In all, 21 patients were excluded from the study due to five spontaneous wide QRS complex (≥120msec, one recent acute coronary syndrome,one significant valvular heart disease, three pacing frequency <90%, eight death or losing follow up in three cases. In remaining 20 patients, LA volume ragned from 21 to 54 mm3 with mean of 37.3±9.7 mm3 prior to pacemaker implantation that increased to 31 to 103 mm3 (54.3±17.0 during follow-up (P<0.001.Conclusion: RVA pacing might lead to an increase in LA volume even in patients with normal LV function.

  7. Recent developments in cardiac pacing.

    Science.gov (United States)

    Rodak, D J

    1995-10-01

    Indications for cardiac pacing continue to expand. Pacing to improve functional capacity, which is now common, relies on careful patient selection and technical improvements, such as complex software algorithms and diagnostic capabilities.

  8. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study.

    Science.gov (United States)

    Kaye, Gerald C; Linker, Nicholas J; Marwick, Thomas H; Pollock, Lucy; Graham, Laura; Pouliot, Erika; Poloniecki, Jan; Gammage, Michael

    2015-04-07

    Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period. We randomized 240 patients (age 74 ± 11 years, 67% male) with a high-grade AV block requiring >90% ventricular pacing and preserved baseline LVEF >50%, to receive pacing at the RVA (n = 120) or RVHS (n = 120). At 2 years, LVEF decreased in both the RVA (57 ± 9 to 55 ± 9%, P = 0.047) and the RVHS groups (56 ± 10 to 54 ± 10%, P = 0.0003). However, there was no significant difference in intra-patient change in LVEF between confirmed RVA (n = 85) and RVHS (n = 83) lead position (P = 0.43). There were no significant differences in heart failure hospitalization, mortality, the burden of atrial fibrillation, or plasma brain natriutetic peptide levels between the two groups. A significantly greater time was required to place the lead in the RVHS position (70 ± 25 vs. 56 ± 24 min, P function requiring a high percentage of ventricular pacing, RVHS pacing does not provide a protective effect on left ventricular function over RVA pacing in the first 2 years. ClinicalTrials.gov number NCT00461734. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  9. Application of MV/LV Transformers with OLTC for Increasing the PV Hosting Capacity Of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Heckmann, Wolfram; Geibel, Dominik

    2015-01-01

    The increased use of grid connected photovoltaic (PV) systems in low voltage (LV) grids also raises concern regarding the effects of these new generation units on the grid operation. Overvoltage in LV grids during high PV generation periods is one of the well-known effects caused by PV systems......) and the reactive power absorption by PV inverters, are investigated using field test results and simulations performed on the mentioned LV grid. The results show that the application of OLTC can effectively increase the PV hosting capacity of the grid......., which potentially can decrease the PV hosting capacity of electric grids. This paper presents the applications of medium voltage to low voltage (MV/LV) transformers with on-load tap changers (OLTCs) to prevent overvoltage in high PV penetration conditions. Autonomous methods for controlling...

  10. Early Right Ventricular Apical Pacing-Induced Gene Expression Alterations Are Associated with Deterioration of Left Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Haiyan Xu

    2017-01-01

    Full Text Available The chronic high-dose right ventricular apical (RVA pacing may have deleterious effects on left ventricular (LV systolic function. We hypothesized that the expression changes of genes regulating cardiomyocyte energy metabolism and contractility were associated with deterioration of LV function in patients who underwent chronic RVA pacing. Sixty patients with complete atrioventricular block and preserved ejection fraction (EF who underwent pacemaker implantation were randomly assigned to either RVA pacing (n=30 group or right ventricular outflow tract (RVOT pacing (n=30 group. The mRNA levels of OPA1 and SERCA2a were significantly lower in the RVA pacing group at 1 month’s follow-up (both p<0.001. Early changes in the expression of selected genes OPA1 and SERCA2a were associated with deterioration in global longitudinal strain (GLS that became apparent months later (p=0.002 and p=0.026, resp. The altered expressions of genes that regulate cardiomyocyte energy metabolism and contractility measured in the peripheral blood at one month following pacemaker implantation were associated with subsequent deterioration in LV dyssynchrony and function in patients with preserved LVEF, who underwent RVA pacing.

  11. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  12. Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

    International Nuclear Information System (INIS)

    Barnett, Joseph; Tavare, Aniket N.; Khan, Sajid; Saini, Ashish; Creer, Dean D.; Hare, Samanjit S.

    2017-01-01

    PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G   core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

  13. Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, Joseph; Tavare, Aniket N. [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom); Khan, Sajid [Royal Free London NHS Foundation Trust, Department of Respiratory Medicine, Barnet Hospital (United Kingdom); Saini, Ashish [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom); Creer, Dean D. [Royal Free London NHS Foundation Trust, Department of Respiratory Medicine, Barnet Hospital (United Kingdom); Hare, Samanjit S., E-mail: samhare@nhs.net [Royal Free London NHS Foundation Trust, Department of Radiology, Barnet Hospital (United Kingdom)

    2017-05-15

    PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G   core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

  14. Pacing-induced Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Alex Koo

    2017-10-01

    Full Text Available We present a case of pacing-induced cardiomyopathy. The patient presented with clinical symptoms of dyspnea, leg swelling, and orthopnea several months after a dual-chambered pacemaker was placed for third-degree heart block. The echocardiogram demonstrated a depressed ejection fraction. Coronary angiography was performed, which showed widely patent vessels. Single- and dual-chambered pacemakers create ventricular dyssynchrony, which in turn can cause structural, molecular changes leading to cardiomyopathy. With early intervention of biventricular pacemaker replacement, these changes can be reversible; thus, a timely diagnosis and awareness is warranted.

  15. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  16. Formation and characterization of FeLV iscoms.

    NARCIS (Netherlands)

    L. Akerblom; K. Strö mstedt; S. Hö glund; A.D.M.E. Osterhaus (Albert); B. Morein (Bror)

    1989-01-01

    textabstractImmunostimulating complexes (ISCOMs) have been prepared from feline leukaemia virus (FeLV) envelope proteins. The ISCOMs were characterized biochemically in SDS-polyacrylamide gel electrophoresis showing the presence of proteins of estimated molecular weights of 15,000, 27,000 and

  17. Smart curtailment for congestion management in LV distribution network

    NARCIS (Netherlands)

    Haque, A. N.M.M.; Rahman, M. T.; Nguyen, P. H.; Bliek, F. W.

    2016-01-01

    The rapid proliferation of distributed energy resources (DERs) leads to capacity challenges, i.e. network congestions, in the low-voltage (LV) distribution networks. A number of strategies are being widely studied to tackle the challenges with direct switching actions such as load shedding or power

  18. The Effect of Right Ventricular Apical and Nonapical Pacing on the Short- and Long-Term Changes in Left Ventricular Ejection Fraction: A Systematic Review and Meta-Analysis of Randomized-Controlled Trials.

    Science.gov (United States)

    Hussain, Mohammad Akhtar; Furuya-Kanamori, Luis; Kaye, Gerald; Clark, Justin; Doi, Suhail A R

    2015-09-01

    The right ventricular apex (RVA) is the traditional lead site for chronic pacing but in some patients may cause impaired left ventricular (LV) systolic function over time. Comparisons with right ventricular nonapical (RVNA) pacing sites have generated inconsistent results and recent meta-analyses have demonstrated unclear benefit due to heterogeneity across studies. A systematic search for randomized controlled trials that compared LV ejection fraction (LVEF) outcomes between RVNA and RVA pacing was performed up to October 2014. Twenty-four studies (n = 1,628 patients) met the inclusion criteria. To avoid between study heterogeneity two homogenous groups were created; group 1 where studies reported a difference (in favor of RVNA pacing) and group 2 where studies reported no difference between pacing sites. For group 1, weighted mean difference between RVNA and RVA pacing in terms of LVEF at follow-up was 5.40% (95% confidence interval [CI]: 3.94-6.87), related in part to group one's RVA arm demonstrating a significant reduction (mean loss -3.31%; 95% CI: -6.19 to -0.43) in LVEF between study baseline and end of follow-up. Neither of these finding were seen in group 2. Weighted regression modeling demonstrated that inclusion of poor baseline LVEF (right ventricular pacing where there is inclusion of impaired baseline LVEF (<40%), RVA pacing is associated with deterioration in LV function relative to RVNA pacing. © 2015 Wiley Periodicals, Inc.

  19. Antiarrhythmic properties of atrial pacing.

    Science.gov (United States)

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  20. Avoided losses on LV networks as a result of microgeneration

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Moises [Escola Superior Tecnologia Viseu, Instituto Politecnico Viseu, Campus Politecnico Repeses, 3504-510 Viseu (Portugal); Matos, Manuel A. [INESC Porto, Faculdade de Engenharia da Universidade do Porto, Porto (Portugal)

    2009-04-15

    In the scope of the discussions about microgeneration (and microgrids), the avoided electrical losses are often pointed out as an important value to be credited to those entities. Therefore, methods to assess the impact of microgeneration on losses must be developed in order to support the definition of a suitable regulatory framework for the economic integration of microgeneration on distribution networks. This paper presents an analytical method to quantify the value of avoided losses that microgeneration may produce on LV networks. Intervals of expected avoided losses are used to account for the variation of avoided losses due to the number, size and location of microgenerators, as well as for the kind of load distribution on LV networks. (author)

  1. A Dynamic and Heuristic Phase Balancing Method for LV Feeders

    Directory of Open Access Journals (Sweden)

    Samad Taghipour Boroujeni

    2016-01-01

    Full Text Available Due to the single-phase loads and their stochastic behavior, the current in the distribution feeders is not balanced. In addition, the single-phase loads are located in different positions along the LV feeders. So the amount of the unbalanced load and its location affect the feeder losses. An unbalanced load causes the feeder losses and the voltage drop. Because of time-varying behavior of the single-phase loads, phase balancing is a dynamic and combinatorial problem. In this research, a heuristic and dynamic solution for the phase balancing of the LV feeders is proposed. In this method, it is supposed that the loads’ tie could be connected to all phases through a three-phase switch. The aim of the proposed method is to make the feeder conditions as balanced as possible. The amount and the location of single-phase loads are considered in the proposed phase balancing method. Since the proposed method needs no communication interface or no remote controller, it is inexpensive, simple, practical, and robust. Applying this method provides a distributed and dynamic phase balancing control. In addition, the feasibility of reducing the used switches is investigated. The ability of the proposed method in the phase balancing of the LV feeders is approved by carrying out some simulations.

  2. Peri-infarct zone pacing to prevent adverse left ventricular remodelling in patients with large myocardial infarction

    DEFF Research Database (Denmark)

    Stone, Gregg W; Chung, Eugene S; Stancak, Branislav

    2016-01-01

    AIMS: We sought to determine whether peri-infarct pacing prevents left ventricular (LV) remodelling and improves functional and clinical outcomes in patients with large first myocardial infarction (MI). METHODS AND RESULTS: A total of 126 patients at 27 international sites within 10 days of onset.......92). There were also no significant between-group differences in the change in LV end-systolic volume or ejection fraction over time. Quality of life, as assessed by the Minnesota Living with Heart Failure (HF) and European Quality of Life-5 Dimension questionnaires and New York Heart Association class, was also...

  3. Optogenetic pacing in Drosophila melanogaster

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Tanzi, Rudolph E.; Zhou, Chao

    2015-01-01

    Electrical stimulation is currently the gold standard for cardiac pacing. However, it is invasive and nonspecific for cardiac tissues. We recently developed a noninvasive cardiac pacing technique using optogenetic tools, which are widely used in neuroscience. Optogenetic pacing of the heart provides high spatial and temporal precisions, is specific for cardiac tissues, avoids artifacts associated with electrical stimulation, and therefore promises to be a powerful tool in basic cardiac research. We demonstrated optogenetic control of heart rhythm in a well-established model organism, Drosophila melanogaster. We developed transgenic flies expressing a light-gated cation channel, channelrhodopsin-2 (ChR2), specifically in their hearts and demonstrated successful optogenetic pacing of ChR2-expressing Drosophila at different developmental stages, including the larva, pupa, and adult stages. A high-speed and ultrahigh-resolution optical coherence microscopy imaging system that is capable of providing images at a rate of 130 frames/s with axial and transverse resolutions of 1.5 and 3.9 μm, respectively, was used to noninvasively monitor Drosophila cardiac function and its response to pacing stimulation. The development of a noninvasive integrated optical pacing and imaging system provides a novel platform for performing research studies in developmental cardiology. PMID:26601299

  4. Direct His bundle pacing post AVN ablation.

    Science.gov (United States)

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  5. Role of HIV-2 envelope in Lv2-mediated restriction

    International Nuclear Information System (INIS)

    Reuter, Sandra; Kaumanns, Patrick; Buschhorn, Sabine B.; Dittmar, Matthias T.

    2005-01-01

    We have characterized envelope protein pseudotyped HIV-2 particles derived from two HIV-2 isolates termed prCBL23 and CBL23 in order to define the role of the envelope protein for the Lv2-mediated restriction to infection. Previously, it has been described that the primary isolate prCBL23 is restricted to infection of several human cell types, whereas the T cell line adapted isolate CBL23 is not restricted in these cell types. Molecular cloning of the two isolates revealed that the env and the gag gene are responsible for the observed phenotype and that this restriction is mediated by Lv2, which is distinct from Ref1/Lv1 (Schmitz, C., Marchant, D., Neil, S.J., Aubin, K., Reuter, S., Dittmar, M.T., McKnight, A., Kizhatil, K., Albritton, L.M., 2004. Lv2, a novel postentry restriction, is mediated by both capsid and envelope. J. Virol. 78 (4), 2006-2016). We generated pseudotyped viruses consisting of HIV-2 (ROD-AΔenv-GFP, ROD-AΔenv-RFP, or ROD-AΔenv-REN) and the prCBL23 or CBL23 envelope proteins as well as chimeric proteins between these envelopes. We demonstrate that a single amino acid exchange at position 74 in the surface unit of CBL23-Env confers restriction to infection. This single point mutation causes tighter CD4 binding, resulting in a less efficient fusion into the cytosol of the restricted cell line. Prevention of endosome formation and prevention of endosome acidification enhance infectivity of the restricted particles for GHOST/X4 cells indicating a degradative lysosomal pathway as a cause for the reduced cytosolic entry. The described restriction to infection of the primary isolate prCBL23 is therefore largely caused by an entry defect. A remaining restriction to infection (19-fold) is preserved when endosomal acidification is prevented. This restriction to infection is also dependent on the presence of the point mutation at position 74 (G74E)

  6. Presentation Time Concerning System-Paced Multimedia Instructions and the Superiority of Learner Pacing

    Science.gov (United States)

    Stiller, Klaus D.; Petzold, Kirstin; Zinnbauer, Peter

    2011-01-01

    The superiority of learner-paced over system-paced instructions was demonstrated in multiple experiments. In these experiments, the system-paced presentations were highly speeded, causing cognitive overload, while the learner-paced instructions allowed adjustments of the presentational flow to the learner's needs by pacing facilities, mostly…

  7. Diagnostic accuracy of pace spikes in the electrocardiogram to diagnose paced rhythm

    DEFF Research Database (Denmark)

    Andersson, Hedvig Bille; Hansen, Marco Bo; Thorsberger, Mads

    2015-01-01

    OBJECTIVE: To determine how often cardiac resynchronization therapy (CRT) pacing systems generate visible pace spikes in the electrocardiogram (ECG). METHODS: In 46 patients treated with CRT pacing systems, we recorded ECGs during intrinsic rhythm, atrial pacing and ventricular pacing. ECGs were...

  8. Is right ventricular mid-septal pacing superior to apical pacing in patients with high degree atrio-ventricular block and moderately depressed left ventricular function?

    Science.gov (United States)

    Chen, Kang; Mao, Ye; Liu, Shao-hua; Wu, Qiong; Luo, Qing-zhi; Pan, Wen-qi; Jin, Qi; Zhang, Ning; Ling, Tian-you; Chen, Ying; Gu, Gang; Shen, Wei-feng; Wu, Li-qun

    2014-06-01

    We are aimed to investigate whether right ventricular mid-septal pacing (RVMSP) is superior to conventional right ventricular apical pacing (RVAP) in improving clinical functional capacity and left ventricular ejection fraction (LVEF) for patients with high-degree atrio-ventricular block and moderately depressed left ventricle (LV) function. Ninety-two patients with high-degree atrio-ventricular block and moderately reduced LVEF (ranging from 35% to 50%) were randomly allocated to RVMSP (n=45) and RVAP (n=47). New York Heart Association (NYHA) functional class, echocardiographic LVEF, and distance during a 6-min walk test (6MWT) were determined at 18 months after pacemaker implantation. Serum levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured using an enzyme-linked immunosorbent assay (ELISA) kit. Compared with baseline, NYHA functional class remained unchanged at 18 months, distance during 6MWT (485 m vs. 517 m) and LVEF (36.7% vs. 41.8%) were increased, but BNP levels were reduced (2352 pg/ml vs. 710 pg/ml) in the RVMSP group compared with those in the RVAP group, especially in patients with LVEF 35%-40% (for all comparisons, Pfunction capacity and LV function measurements were not significantly changed in patients with RVAP, despite the pacing measurements being similar in both groups, such as R-wave amplitude and capture threshold. RVMSP provides a better clinical utility, compared with RVAP, in patients with high-degree atrioventricular block and moderately depressed LV function whose LVEF levels ranged from 35% to 40%.

  9. Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study

    Science.gov (United States)

    Leclercq, Christophe; Sadoul, Nicolas; Mont, Lluis; Defaye, Pascal; Osca, Joaquim; Mouton, Elisabeth; Isnard, Richard; Habib, Gilbert; Zamorano, Jose; Derumeaux, Genevieve; Fernandez-Lozano, Ignacio; Dupuis, Jean-Marc; Rouleau, Frédéric; Tassin, Aude; Bordachar, Pierre; Clémenty, Jacques; Lafitte, Stephane; Ploux, Sylvan; Reant, Patricia; Ritter, Philippe; Defaye, Pascal; Jacon, Peggy; Mondesert, Blandine; Saunier, Carole; Vautrin, Estelle; Kacet, Salem; Guedon-Moreau, Laurence; Klug, Didier; Kouakam, Claude; Marechaux, Sylvestre; Marquie, Christelle; Polge, Anne Sophie; Richardson, Marjorie; Chevallier, Philippe; De Breyne, Brigitte; Lotek, Marcin M.; Nonin, Emilie; Pineau, Julien; Deharo, Jean-Claude; Bastard, Emilie; Franceschi, Frédéric; Habib, Gilbert; Jego, Christophe; Peyrouse, Eric; Prevot, Sebastien; Saint-Joseph, Hôpital; Bremondy, Michel; Faure, Jacques; Ferracci, Ange; Lefevre, Jean; Pisapia, Andre; Davy, Jean-Marc; Cransac, Frederic; Cung, Tien Tri; Georger, Frederic; Pasquie, Jean-Luc; Raczka, Franck; Sportouch-Dukhan, Catherine; Sadoul, Nicolas; Blangy, Hugues; Bruntz, Jean-François; Freysz, Luc; Groben, Laurent; Huttin, Olivier; Bammert, Antoine; Burban, Marc; Cebron, Jean-Pierre; Gras, Daniel; Frank, Robert; Duthoit, Guillaume; Hidden-Lucet, Françoise; Himbert, Caroline; Isnard, Richard; Lacotte, Jérôme; Pousset, Françoise; Zerah, Thierry; Leclercq, Christophe; Bellouin, Annaïk; Crocq, Christophe; Deplace, Christian; Donal, Erwan; Hamon, Cécile; Mabo, Philippe; Romain, Olivier; Solnon, Aude; Frederic, Anselme; Bauer, Fabrice; Bernard, Mathieu; Godin, Benedicte; Kurtz, Baptiste; Savoure, Arnaud; Copie, Xavier; Lascault, Gilles; Paziaud, Olivier; Piot, Olivier; Touche, Thierry; Delay, Toulouse Marc; Chilon, Talia; Detis, Nicolas; Duparc, Alexandre; Hebrard, Aurélien; Massabuau, Pierre; Maury, Philippe; Mondoly, Pierre; Rumeau, Philippe; Pasteur, Clinique; Boveda, Serge; Adrover, Laurence; Combes, Nicolas; Deplagne, Antoine; Marco-Baertich, Isabelle; Fondard, Olivier; Martínez, Juan Gabriel; Ibañez Criado, José Luis; Ortuño, Diego; Mont, Lluis; Berruezo, Antonio; Eduard, Belu; Martín, Ana; Merschon, Franco M.; Sitges, Marta; Tolosana, José María; Vidal, Bárbara; Hebron, H. Valle; i Mitjans, Angel Moya; Rodriguez, Oscar Alcalde; Rodriguez Palomares, José Fernando; Rivas, Nuria; Teixidó, Gisela; de Hierro, H. Puerta; Lozano, Ignacio Fernández; Ruiz Bautista, Maria Lorena; Castro, Victor; Cavero, Miguel Angel; Gutierrez, Carlos; Ros, Natalia; de la Victoria, H. Virgen; Alzueta Rodriguez, Francisco Javier; Cabrera, Fernando; Cordero, Alberto Barrera; Peña, José Luis; de Valme Sevilla, H.; Gonzáles, Juan Lealdel Ojo; Garcia Medina, Mª Dolores; Jiménez, Ricardo Pavón; Villagomez, David; de la Salud Toledo, H. Virgen; Castellanos Martinez, Eduardo; Alcalá, Juan; Maicas, Carolina; Arias Palomares, Miguel Angel; Puchol, Alberto; Valencia, H. La Fé; OscaAsensi, Joaquim; Carmona, Anastasio Quesada; De Carranza, Mª José Sancho-Tello; De Ros, José Olagüe; Pareja, Enrique Castro; Pérez, Oscar Cano; Saez, Ana Osa; Hortega, H. Rio; Guilarte, Benito Herreros; Muñoz San Jose, Juan Francisco; Pérez Sanz, Teresa Myriam; Logeart, Damien; Gil, Maria Lopez; Leclercq, Christophe; Lozano, Ignacio Fernandez; de Hierro, H. Puerta; Derumeaux, Genevieve

    2016-01-01

    Abstract Aims Cardiac resynchronization therapy (CRT) is a recommended treatment of heart failure (HF) patients with depressed left ventricular ejection fraction and wide QRS. The optimal right ventricular (RV) lead position being a matter of debate, we sought to examine whether RV septal (RVS) pacing was not inferior to RV apical (RVA) pacing on left ventricular reverse remodelling in patients receiving a CRT-defibrillator. Methods and results Patients (n = 263, age = 63.4 ± 9.5 years) were randomly assigned in a 1:1 ratio to RVS (n = 131) vs. RVA (n = 132) pacing. Left ventricular end-systolic volume (LVESV) reduction between baseline and 6 months was not different between the two groups (−25.3 ± 39.4 mL in RVS group vs. −29.3 ± 44.5 mL in RVA group, P = 0.79). Right ventricular septal pacing was not non-inferior (primary endpoint) to RVA pacing with regard to LVESV reduction (average difference = −4.06 mL; P = 0.006 with a −20 mL non-inferiority margin). The percentage of ‘echo-responders’ defined by LVESV reduction >15% between baseline and 6 months was similar in both groups (50%) with no difference in the time to first HF hospitalization or death (P = 0.532). Procedural or device-related serious adverse events occurred in 68 patients (RVS = 37) with no difference between the two groups (P = 0.401). Conclusion This study demonstrates that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome. No recommendation for optimal RV lead position can hence be drawn from this study. ClinicalTrials. gov number NCT 00833352. PMID:26374852

  10. A targeted mutation within the feline leukemia virus (FeLV) envelope protein immunosuppressive domain to improve a canarypox virus-vectored FeLV vaccine.

    Science.gov (United States)

    Schlecht-Louf, Géraldine; Mangeney, Marianne; El-Garch, Hanane; Lacombe, Valérie; Poulet, Hervé; Heidmann, Thierry

    2014-01-01

    We previously delineated a highly conserved immunosuppressive (IS) domain within murine and primate retroviral envelope proteins that is critical for virus propagation in vivo. The envelope-mediated immunosuppression was assessed by the ability of the proteins, when expressed by allogeneic tumor cells normally rejected by engrafted mice, to allow these cells to escape, at least transiently, immune rejection. Using this approach, we identified key residues whose mutation (i) specifically abolishes immunosuppressive activity without affecting the "mechanical" function of the envelope protein and (ii) significantly enhances humoral and cellular immune responses elicited against the virus. The objective of this work was to study the immunosuppressive activity of the envelope protein (p15E) of feline leukemia virus (FeLV) and evaluate the effect of its abolition on the efficacy of a vaccine against FeLV. Here we demonstrate that the FeLV envelope protein is immunosuppressive in vivo and that this immunosuppressive activity can be "switched off" by targeted mutation of a specific amino acid. As a result of the introduction of the mutated envelope sequence into a previously well characterized canarypox virus-vectored vaccine (ALVAC-FeLV), the frequency of vaccine-induced FeLV-specific gamma interferon (IFN-γ)-producing cells was increased, whereas conversely, the frequency of vaccine-induced FeLV-specific interleukin-10 (IL-10)-producing cells was reduced. This shift in the IFN-γ/IL-10 response was associated with a higher efficacy of ALVAC-FeLV against FeLV infection. This study demonstrates that FeLV p15E is immunosuppressive in vivo, that the immunosuppressive domain of p15E can modulate the FeLV-specific immune response, and that the efficacy of FeLV vaccines can be enhanced by inhibiting the immunosuppressive activity of the IS domain through an appropriate mutation.

  11. Alternative right ventricular pacing sites.

    Science.gov (United States)

    Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek

    2015-01-01

    The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.

  12. Pace studying worldwide coke production

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Pace Consultants Inc., Houston, has started a multiclient study of world-wide petroleum coke production, examining environmental initiatives and eventually forecasting prices of fuel grade coke. Pace expects coker expansions, increased operating severity, and reduced cycle times to boost coke supply to more than 50 million metric tons/year in 2000, compared with 39.7 million metric tons in 1992. Increased supply and tightened environmental rules in countries consuming large amounts of petroleum coke will be the main factors affecting coke markets. The paper discusses coke quality and the Japanese market

  13. E/e' Ratio: An Index of LV Filling Pressures Revisited

    Directory of Open Access Journals (Sweden)

    Sherif F. Nagueh

    2013-01-01

    Full Text Available There is a clinical need for the assessment of cardiac function in patients who present with symptoms and signs of pulmonary and systemic congestion. Echocardiography has been utilized over the years to answer this question. It is possible to study left ventricular (LV systolic and diastolic function as well as pulmonary artery pressures and right ventricular function using this technique. With respect to LV diastolic function, an ideal assessment includes evaluation of LV relaxation and LV filling pressures. There are several parameters that when properly acquired and analyzed can predict the 2 fundamental aspects noted above of LV diastolic function. The mitral annulus early diastolic recoil velocity (e’ recorded by tissue Doppler imaging (TDI was introduced as an index of LV relaxation. Further, e’ velocity is combined with mitral peak velocity E to predict LV filling pressures1. I will discuss the supporting literature for the last statement and point to the limitations in its application.

  14. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  15. PACE: A Browsable Graphical Interface.

    Science.gov (United States)

    Beheshti, Jamshid; And Others

    1996-01-01

    Describes PACE (Public Access Catalogue Extension), an alternative interface designed to enhance online catalogs by simulating images of books and library shelves to help users browse through the catalog. Results of a test in a college library against a text-based online public access catalog, including student attitudes, are described.…

  16. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  17. Comparative Efficacy of Feline Leukemia Virus (FeLV) Inactivated Whole-Virus Vaccine and Canarypox Virus-Vectored Vaccine during Virulent FeLV Challenge and Immunosuppression.

    Science.gov (United States)

    Patel, M; Carritt, K; Lane, J; Jayappa, H; Stahl, M; Bourgeois, M

    2015-07-01

    Four vaccines for feline leukemia virus (FeLV) are available in the United States. This study's purpose was to compare the efficacy of Nobivac feline 2-FeLV (an inactivated, adjuvanted whole-virus vaccine) and PureVax recombinant FeLV (a live, canarypox virus-vectored vaccine) following FeLV challenge. Cats were vaccinated at 9 and 12 weeks with Nobivac feline 2-FeLV (group A, n = 11) or PureVax recombinant FeLV (group B, n = 10). Group C (n = 11) comprised unvaccinated controls. At 3 months postvaccination, cats were immunosuppressed and challenged with FeLV-A/61E. The outcomes measured were persistent antigenemia at 12 weeks postchallenge (PC) and proviral DNA and viral RNA at 3 to 9 weeks PC. Persistent antigenemia was observed in 0 of 11 cats in group A, 5 of 10 cats in group B, and 10 of 11 cats in group C. Group A was significantly protected compared to those in groups B (P 0.063). The preventable fraction was 100% for group A and 45% for group B. At 9 weeks PC, proviral DNA and viral RNA were detected 1 of 11 cats in group A, 6 of 10 cats in group B, and 9 of 11 cats in group C. Nucleic acid loads were significantly lower in group A than in group C (P feline 2-FeLV-vaccinated cats were fully protected against persistent antigenemia and had significantly smaller amounts of proviral DNA and plasma viral RNA loads than PureVax recombinant FeLV-vaccinated cats and unvaccinated controls. Copyright © 2015, Patel et al.

  18. Breath pacing system and method for pacing the respiratory activity of a subject

    NARCIS (Netherlands)

    2016-01-01

    To provide a breath pacing system and a corresponding method for pacing the respiratory activity of a subject that provide the possibility to adapt the output signal to the respiration characteristics of the subject automatically and effectively a breath pacing system (10) for pacing the respiratory

  19. Mast cell stabilization decreases cardiomyocyte and LV function in dogs with isolated mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Killingsworth, Cheryl; Chen, Yuanwen; Gladden, James D; Walcott, Greg; Powell, Pamela C; Denney, Thomas; Gupta, Himanshu; Desai, Ravi; Tillson, Michael; Dillon, A Ray; Dell'italia, Louis J

    2010-09-01

    Mast cells are increased in isolated mitral regurgitation (MR) in the dog and may mediate extracellular matrix loss and left ventricular (LV) dilatation. We tested the hypothesis that mast cell stabilization would attenuate LV remodeling and improve function in the MR dog. MR was induced in adult dogs randomized to no treatment (MR, n = 5) or to the mast cell stabilizer, ketotifen (MR + MCS, n = 4) for 4 months. LV hemodynamics were obtained at baseline and after 4 months of MR and magnetic resonance imaging (MRI) was performed at sacrifice. MRI-derived, serial, short-axis LV end-diastolic (ED) and end-systolic (ES) volumes, LVED volume/mass ratio, and LV 3-dimensional radius/wall thickness were increased in MR and MR + MCS dogs compared with normal dogs (n = 6) (P < .05). Interstitial collagen was decreased by 30% in both MR and MR + MCS versus normal dogs (P < .05). LV contractility by LV maximum time-varying elastance was significantly depressed in MR and MR + MCS dogs. Furthermore, cardiomyocyte fractional shortening was decreased in MR versus normal dogs and further depressed in MR + MCS dogs (P < .05). In vitro administration of ketotifen to normal cardiomyocytes also significantly decreased fractional shortening and calcium transients. Chronic mast cell stabilization did not attenuate eccentric LV remodeling or collagen loss in MR. However, MCS therapy had a detrimental effect on LV function because of a direct negative inotropic effect on cardiomyocyte function. Published by Elsevier Inc.

  20. Energy levels, lifetimes and radiative data of W LV

    Science.gov (United States)

    Ding, Xiao-bin; Sun, Rui; Koike, Fumihiro; Murakami, Izumi; Kato, Daiji; Sakaue, Hiroyuki A.; Nakamura, Nobuyuki; Dong, Chen-zhong

    2018-01-01

    Calculations of energy levels, radiative data and lifetimes are reported for tungsten Ca-like ion (W LV) by using multi-configuration Dirac-Fock (MCDF) method. The GRASP2K package is adopted to carry out a large-scale systematic computation with a restricted active space treatment; the Breit interaction and QED effects are included in subsequent relativistic configuration interaction calculations. The energies and lifetimes of the lowest 119 levels are listed; the main leading configuration of the levels is of the ground state configuration [Ne]3s23p63d2 and the first excited configuration [Ne]3s23p53d3. The wavelengths, radiative rates and oscillator strengths for relatively strong E1, E2, M1, and M2 transitions are listed. Comparisons with earlier experimental and theoretical values are made. The average relative deviations of energy levels from the NIST results and E1 transition wavelengths from the EBIT experimental results have turned to be only 0.20% and 0.13%, respectively. The other present results are in reasonable agreement with available data. These agreements confirm the reliability and accuracy of the current results. The present datasets may help us with the investigation of the electron-electron correlation effects in complex multi-electron highly charged heavy ions and of the diagnosis of tungsten impurity plasmas in fusion science.

  1. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.; Amidan, Brett G.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

  2. The Use of a Quadripolar Left Ventricular Lead Increases Successful Implantation Rates in Patients with Phrenic Nerve Stimulation and/or High Pacing Thresholds Undergoing Cardiac Resynchronisation Therapy with Conventional Bipolar Leads

    Directory of Open Access Journals (Sweden)

    Marc-Alexander Ohlow, MD

    2013-03-01

    Conclusions: Excessively HPT and/or PNS are frequently encountered when conventional bipolar leads are used for CRT. A new quadripolar LV lead increases the rate of successful biventricular stimulation. Lower pacing threshold and freedom from PNS are maintained at follow-up.

  3. Application of SPCALC for chemical and thermodynamic speciation of fluids -example for wells LV-4A, LV-11 and LV-13, Las Tres Virgenes geothermal field, BCS; Aplicacion del SPCALC en la especiacion quimica y termodinamica de fluidos: ejemplo del caso de los pozos LV-4A, LV-11 y LV-13, del campo geotermico de Las Tres Virgenes, BCS

    Energy Technology Data Exchange (ETDEWEB)

    Viggiano Guerra, J.C.; Sandoval Medina, F.; Flores Armenta, M.C. [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)]. E-mail: fernando.sandoval@cfe.gob.mx, E-mail: magaly.flores@cfe.gob.mx; Perez, R.J. [Universidad de Calgary (Canada); Gonzalez Partida, E. [Universidad Nacional Autonoma de Mexico, Centro de Geociencias, Mexico, D.F. (Mexico)

    2009-01-15

    SPCALC is an excellent software application providing chemical and multi-phase speciation for geothermal fluids. Recently it was acquired by the Comision Federal de Electricidad (CFE) through a contract with the National Autonomous University of Mexico (UNAM) and the University of Calgary, Canada. Software methodology consists of calculating thermodynamic variables, such as activity (a) and fugacity (f) of chemical species, as well as the saturation indices (log Q/K) of mineral phases of the reservoir. In other words, it models the thermodynamic conditions of the reservoir (pH among other) and simulates the fluid-corrosion rate. This allows the software to foresee scaling and corrosion. In this paper, pervasive fluids in Cretaceous granitic rocks penetrated by wells LV-4A, LV-11 and LV-13 in Las Tres Virgenes geothermal field, BCS, are modeled, starting with chemical analyses. The more important ratios among activities [those which influence the fluid-rock interaction (i.e. {sup a}K{sup +}/{sup a}H{sup +}, {sup a}Ca{sup ++}/{sup a}H{sup +}, {sup a}Na{sup +}/{sup a}H{sup +}, {sup a}Mg{sup ++}/{sup a}H{sup +}) and whose results are the minerals visible under a microscope] are graphed in balance diagrams compatible with the pressure (P) and temperature (T) conditions in the reservoir. Epidote (zoisite) is the mineral found in congruent equilibrium with the system. The main mineral association at those conditions (200-250 degrees Celsius and {approx}18 bar), as observed in the well cuttings, is calcite+illite-quartz{+-}epidote, which is explained by the hydrolithic reactions that form replacement calcite in the presence of CO{sub 2}, thus restricting the formation of epidote and eventually eliminating it. The process enhances the CO{sub 2} molarity in the residual fluid, even up to {sup m}CO{sub 2} 1, which means the CO{sub 2} can be diluted back into fluid and intervene again in the process of calcite formation (2HCO{sub 3}{sup -} + Ca{sup ++} = calcite + H{sub 2}O

  4. Studies on the synthesis of isotopes of superheavy element Lv (Z = 116)

    Energy Technology Data Exchange (ETDEWEB)

    Santhosh, K.P.; Safoora, V. [Kannur University, School of Pure and Applied Physics, Payyanur (India)

    2017-11-15

    The probable projectile-target combinations for the synthesis of superheavy nucleus {sup 296}Lv found in the cold valley of {sup 296}Lv have been identified by studying the interaction barrier of the colliding nuclei, probability of compound nucleus formation, P{sub CN}, and survival probability W{sub sur}. At energies near and above the Coulomb barrier, the capture, fusion and evaporation residue (ER) cross sections for the probable combinations for the hot and cold fusion reactions are systematically investigated. By considering intensities of the projectile beams, availabilities of the targets and half lives of the colliding nuclei, the combination {sup 48}Ca + {sup 248}Cm is found to be the most probable projectile-target pair for the synthesis of {sup 296}Lv. The calculated maximum value of 2n, 3n, 4n and 5n channel cross section for the reaction {sup 48}Ca + {sup 248}Cm are 0.599 pb, 5.957 pb, 4.805 pb, and 0.065 pb, respectively. Moreover, the production cross sections for the synthesis of isotopes {sup 291-295,298}Lv using {sup 48}Ca projectile on {sup 243-247,250}Cm targets are calculated. Among these reactions, the reactions {sup 48}Ca + {sup 247}Cm → {sup 295}Lv and {sup 48}Ca + {sup 250}Cm → {sup 298}Lv have maximum production cross section in 3n (10.697 pb) and 4n (12.006 pb) channel, respectively. Our studies on the SHE Lv using the combinations {sup 48}Ca + {sup 245}Cm → {sup 293}Lv and {sup 48}Ca + {sup 248}Cm → {sup 296}Lv are compared with available experimental data and with other theoretical studies. Our studies are in agreement with experimental data and we hope that these studies will be a guide for the future experiments to synthesize the isotopes of Lv. (orig.)

  5. Risk perception influences athletic pacing strategy.

    Science.gov (United States)

    Micklewright, Dominic; Parry, David; Robinson, Tracy; Deacon, Greg; Renfree, Andrew; St Clair Gibson, Alan; Matthews, William J

    2015-05-01

    The objective of this study is to examine risk taking and risk perception associations with perceived exertion, pacing, and performance in athletes. Two experiments were conducted in which risk perception was assessed using the domain-specific risk taking (DOSPERT) scale in 20 novice cyclists (experiment 1) and 32 experienced ultramarathon runners (experiment 2). In experiment 1, participants predicted their pace and then performed a 5-km maximum effort cycling time trial on a calibrated Kingcycle mounted bicycle. Split times and perceived exertion were recorded every kilometer. In experiment 2, each participant predicted their split times before running a 100-km ultramarathon. Split times and perceived exertion were recorded at seven checkpoints. In both experiments, higher and lower risk perception groups were created using median split of DOSPERT scores. In experiment 1, pace during the first kilometer was faster among lower risk perceivers compared with higher risk perceivers (t(18) = 2.0, P = 0.03) and faster among higher risk takers compared with lower risk takers (t(18) = 2.2, P = 0.02). Actual pace was slower than predicted pace during the first kilometer in both the higher risk perceivers (t(9) = -4.2, P = 0.001) and lower risk perceivers (t(9) = -1.8, P = 0.049). In experiment 2, pace during the first 36 km was faster among lower risk perceivers compared with higher risk perceivers (t(16) = 2.0, P = 0.03). Irrespective of risk perception group, actual pace was slower than predicted pace during the first 18 km (t(16) = 8.9, P risk perception groups. Initial pace is associated with an individual's perception of risk, with low perceptions of risk being associated with a faster starting pace. Large differences between predicted and actual pace suggest that the performance template lacks accuracy, perhaps indicating greater reliance on momentary pacing decisions rather than preplanned strategy.

  6. Characterizing Spatial Dynamics of Bifurcation to Alternans in Isolated Whole Rabbit Hearts Based on Alternate Pacing

    Directory of Open Access Journals (Sweden)

    Kanchan Kulkarni

    2015-01-01

    Full Text Available Sudden cardiac death instigated by ventricular fibrillation (VF is the largest cause of natural death in the USA. Alternans, a beat-to-beat alternation in the action potential duration, has been implicated as being proarrhythmic. The onset of alternans is mediated via a bifurcation, which may occur through either a smooth or a border-collision mechanism. The objective of this study was to characterize the mechanism of bifurcation to alternans based on experiments in isolated whole rabbit hearts. High resolution optical mapping was performed and the electrical activity was recorded from the left ventricle (LV epicardial surface of the heart. Each heart was paced using an “alternate pacing protocol,” where the basic cycle length (BCL was alternatively perturbed by ±δ. Local onset of alternans in the heart, BCLstart, was measured in the absence of perturbations (δ=0 and was defined as the BCL at which 10% of LV exhibited alternans. The influences of perturbation size were investigated at two BCLs: one prior to BCLstart (BCLprior=BCLstart+20 ms and one preceding BCLprior (BCLfar=BCLstart+40 ms. Our results demonstrate significant spatial correlation of the region exhibiting alternans with smooth bifurcation characteristics, indicating that transition to alternans in isolated rabbit hearts occurs predominantly through smooth bifurcation.

  7. Effect of chronic right ventricular apical pacing on left ventricular function.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Jones, Philip G; Thompson, Randall C; Bateman, Timothy M; McGhie, A Iain; Ramza, Brian M; Steinhaus, David M

    2005-03-15

    The determinants of change in left ventricular (LV) ejection fraction (EF) over time in patients with impaired LV function at baseline have not been clearly established. Using a nuclear database to assess changes in LV function over time, we included patients with a baseline LVEF of 25% to 40% on a gated single-photon emission computed tomographic study at rest and only if second-gated photon emission computed tomography performed approximately 18 months after the initial study showed an improvement in LVEF at rest of > or =10 points or a decrease in LVEF at rest of > or =7 points. In all, 148 patients qualified for the EF increase group and 59 patients for the EF decrease group. LVEF on average increased from 33 +/- 4% to 51 +/- 8% in the EF increase group and decreased from 35 +/- 4% to 25 +/- 5% in the EF decrease group. The strongest multivariable predictor of improvement of LVEF was beta-blocker therapy (odds ratio 3.9, p = 0.002). The strongest independent predictor of LVEF decrease was the presence of a permanent right ventricular apical pacemaker (odds ratio 6.6, p = 0.002). Thus, this study identified beta-blocker therapy as the major independent predictor for improvement in LVEF of > or =10 points, whereas a permanent pacemaker (right ventricular apical pacing) was the strongest predictor of a LVEF decrease of > or =7 points.

  8. Biodegradation of di-n-butyl phthalate by bacterial consortium LV-1 enriched from river sludge.

    Directory of Open Access Journals (Sweden)

    Yangyang Wang

    Full Text Available A stable bacterial consortium (LV-1 capable of degrading di-n-butyl phthalate (DBP was enriched from river sludge. Community analysis revealed that the main families of LV-1 are Brucellaceae (62.78% and Sinobacteraceae (14.83%, and the main genera of LV-1 are Brucella spp. (62.78% and Sinobacter spp. (14.83%. The optimal pH and temperature for LV-1 to degrade DBP were pH 6.0 and 30°C, respectively. Inoculum size influenced the degradation ratio when the incubation time was < 24 h. The initial concentration of DBP also influenced the degradation rates of DBP by LV-1, and the degradation rates ranged from 69.0-775.0 mg/l/d in the first 24 h. Degradation of DBP was best fitted by first-order kinetics when the initial concentration was < 300 mg/l. In addition, Cd2+, Cr6+, and Zn2+ inhibited DBP degradation by LV-1 at all considered concentrations, but low concentrations of Pb2+, Cu2+, and Mn2+ enhanced DBP degradation. The main intermediates (mono-ethyl phthalate [MEP], mono-butyl phthalate [MBP], and phthalic acid [PA] were identified in the DBP degradation process, thus a new biochemical pathway of DBP degradation is proposed. Furthermore, LV-1 also degraded other phthalates with shorter ester chains (DMP, DEP, and PA.

  9. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    Science.gov (United States)

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  10. Removal of the liquid waste storage tank LV-2 in JRTF. Part 2. Removal works

    International Nuclear Information System (INIS)

    Kanayama, Fumihiko; Hagiya, Kazuaki; Sunaoshi, Mizuho; Muraguchi, Yoshinori; Satomi, Shinichi; Nemoto, Kouichi; Terunuma, Akihiro; Shiraishi, Kunio; Ito, Shinichi

    2011-06-01

    Dismantling activities of components in JAERI's Reprocessing Test Facility (JRTF) started from 1996 as a part of decommissioning of this facility. Removing out of a large liquid waste storage tank LV-2 as a whole tank from the annex building B without cutting in pieces to confirm safety and efficiency of this method started from 2006. After preparatory works, ceiling of LV-2 room was opened, and LV-2 was transferred. Useful data such as manpower, radiation control and waste amount through these works were collected, and work efficiency was analyzed by using of these data. (author)

  11. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    OpenAIRE

    Domenico Santarsiero

    2008-01-01

    The Applanix POS/LV platform in cinematic laser scanner applicationsOn the 11th of march the GEOmedia editorial unit had the pleasure of hosting a technical meeting dedicated to the Applanix LANDMark new Position and Orientation System for Land Vehicles (POS/LV)field test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products) and Terenzio Mariani (Sales manager for Italy), helped to test the functionalities of a complete POS/LV system equ...

  12. Impact Study of Electric Vehicle (EV) Integration on Low Voltage (LV) Grids

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cha, Seung-Tae; Nielsen, Arne Hejde

    2012-01-01

    the single line diagram (SLD) of the LV grid. The demand profiles of end-users are determined by the end-user yearly consumption and avreaged demand profiles of different customer types in Denmark. Five charging scenarios have been tested using the developed LV grid. The first two charging scenarios are dumb....... The two charging power levels are 1 phase 16 A and 3 phase 16 A. The loading of the power components and voltage profile are analyzed to quantify the impact of the charging scenarios and charging power levels on LV grids....

  13. Estudio de las cualidades inmunoestimulantes de nuevas bacterias probióticas asociadas al cultivo de lv

    OpenAIRE

    Gullian, Mariel; Rodríguez, Jenny

    2002-01-01

    Estudio de las cualidades inmunoestimulantes de nuevas bacterias probióticas asociadas al cultivo de LV Estudio de las cualidades inmunoestimulantes de nuevas bacterias probióticas asociadas al cultivo de LV

  14. CAMAC interface module for PACE ADC system

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, C G; Mischke, R E [Los Alamos Scientific Lab., N.Mex. (USA); Scott, D T

    1977-03-15

    This report describes a CAMAC module designed to buffer and transfer data from the Tennelec multiplexed ADC system called PACE to a computer. It can be operated in either of two modes: as an eight-deep, first-in-first-out (FIFO) circular buffer, or in channel mode with a single buffer reserved for each PACE channel.

  15. Web Tools: Keeping Learners on Pace

    Science.gov (United States)

    Kosloski, Mickey

    2016-01-01

    One of the greatest challenges in teaching technology and engineering is pacing. Some students grasp new technological concepts quickly, while others need repetition and may struggle to keep pace. This poses an obstacle for the technology and engineering teacher, and is particularly true when teaching students to build a website. However, there…

  16. 42 CFR 460.60 - PACE organizational structure.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE organizational structure. 460.60 Section 460... ELDERLY (PACE) PACE Administrative Requirements § 460.60 PACE organizational structure. (a) A PACE organization must be, or be a distinct part of, one of the following: (1) An entity of city, county, State, or...

  17. Hemodynamic stress testing using pacing tachycardia

    International Nuclear Information System (INIS)

    McKay, R.G.; Grossman, W.

    1986-01-01

    A trial pacing was first introduced in 1967 by Sowton and co-workers as a stress test which could be used in the cardiac catheterization laboratory to evaluate patients with schemic heart disease. Sowton noted that artificially increasing the heart rate by pacing the right atrium could usually induce angina in patients with symptomatic coronary artery disease. Since Sowton's original description, numerous investigators have described characteristic pacing-induced electrocardiographic changes, derangements of myocardial lactate metabolism, hemodynamic abnormalities, regional wall abnormalities, and defects in thallium scintigraphy. Although agreement on the overall usefulness of atrial pacing has not been uniform, it is clear that the technique can safely and reliably induce ischemia in most patients with coronary artery disease and that information obtained during the pacing-induced ischemic state can often be helpful in the diagnosis and treatment of the patient's underlying disease

  18. LV function monitoring to discard functional abnormalities in athletes with altered ventricular re-polarization

    International Nuclear Information System (INIS)

    Flotats, A.; Camacho, V.; Mena, E.; Tembl, A.; Estorch, M.; Carrio, I.; Serra-Grima, R.; Borras, X.; Cinca, J.

    2002-01-01

    Aim: Marked ventricular re-polarization abnormalities (MRA) in athletes may suggest the presence of associated heart disease. Assessment of LV function during exercise may contribute to rule out heart disease and help to decide continuation of physical training. The aim of the study was to assess whether athletes with MRA show a particular response of LV function to exhausting exercise. Material and Methods: Thirty-nine male athletes underwent monitoring of LV function with a miniaturised radionuclide detector (VEST, Capintec, Inc.) during bicycle exhausting exercise. There were 22 athletes with MRA in the ECG at rest (negative T waves equal or more than 2mm in up to 3 ECG leads) and 17 with normal ECG. All were symptom free. Age and physical fitness were comparable in both groups. Clinical examination, ECG, exercise test and echocardiography were performed in all athletes. Results: In all cases LV wall thickness was that expected for highly conditioned sportsmen. Both groups of athletes attained a similar energy expenditure. During exercise, athletes with MRA showed a tendency to normalise re-polarization. There were no differences in heart rate, LV end-systolic volume, LVEF, cardiac output , and peak ejection and filling rates at rest, 50%, 75%, 85% and 100% of peak HR, nor at 2, 5 and 10 min of recovery between both groups of athletes. At rest stroke volume was lower in athletes with MRA (60% vs. 64%, p=0.044). There were also no differences in LV end-diastolic volume (EDV), except at peak HR, when EDV increased in athletes with normal ECG while it decreased in athletes with MRA (p=0.047). Conclusions: The presence of marked ventricular re-polarization abnormalities in athletes does not substantially affect exercise performance nor LV function and should not preclude physical training. The VEST is a useful means to assess LV function during exhausting upright bicycle exercise

  19. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.

    Science.gov (United States)

    Sławuta, Agnieszka; Kliś, Magdalena; Skoczyński, Przemysław; Bańkowski, Tomasz; Moszczyńska-Stulin, Joanna; Gajek, Jacek

    2016-01-01

    Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.

  20. PACE: Proactively Secure Accumulo with Cryptographic Enforcement

    Science.gov (United States)

    2017-05-27

    will be replaced with the values from the decrypted destination field. PACE encrypts data using AES and supports the following modes: CTR, CFB, CBC, OFB...2) Searchable Encryption : PACE also support searching for encrypted data. This is done using AES in SIV mode [11] to provide deterministic encryption ...row ”Alphabet”), then the search term is encrypted deterministically, and that term is searched on the server. Because AES does not preserve the

  1. Optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    A non-invasive, contact-less cardiac pacing technology can be a powerful tool in basic cardiac research and in clinics. Currently, electrical pacing is the gold standard for cardiac pacing. Although highly effective in controlling the cardiac function, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its capabilities. Optical pacing of heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids shortcomings in electrical stimulation. Optical coherence tomography has been proved to be an effective technique in non-invasive imaging in vivo with ultrahigh resolution and imaging speed. In the last several years, non-invasive specific optical pacing in animal hearts has been reported in quail, zebrafish, and rabbit models. However, Drosophila Melanogaster, which is a significant model with orthologs of 75% of human disease genes, has rarely been studied concerning their optical pacing in heart. Here, we combined optogenetic control of Drosophila heartbeat with optical coherence microscopy (OCM) technique for the first time. The light-gated cation channel, channelrhodopsin-2 (ChR2) was specifically expressed by transgene as a pacemaker in drosophila heart. By stimulating the pacemaker with 472 nm pulsed laser light at different frequencies, we achieved non-invasive and more specific optical control of the Drosophila heart rhythm, which demonstrates the wide potential of optical pacing for studying cardiac dynamics and development. Imaging capability of our customized OCM system was also involved to observe the pacing effect visually. No tissue damage was found after long exposure to laser pulses, which proved the safety of optogenetic control of Drosophila heart.

  2. Altering Pace Control and Pace Regulation: Attentional Focus Effects during Running.

    Science.gov (United States)

    Brick, Noel E; Campbell, Mark J; Metcalfe, Richard S; Mair, Jacqueline L; Macintyre, Tadhg E

    2016-05-01

    To date, there are no published studies directly comparing self-controlled (SC) and externally controlled (EC) pace endurance tasks. However, previous research suggests pace control may impact on cognitive strategy use and effort perceptions. The primary aim of this study was to investigate the effects of manipulating perception of pace control on attentional focus, physiological, and psychological outcomes during running. The secondary aim was to determine the reproducibility of self-paced running performance when regulated by effort perceptions. Twenty experienced endurance runners completed four 3-km time trials on a treadmill. Subjects completed two SC pace trials, one perceived exertion clamped (PE) trial, and one EC pace time trial. PE and EC were completed in a counterbalanced order. Pacing strategy for EC and perceived exertion instructions for PE replicated the subjects' fastest SC time trial. Subjects reported a greater focus on cognitive strategies such as relaxing and optimizing running action during EC than during SC. The mean HR was 2% lower during EC than that during SC despite an identical pacing strategy. Perceived exertion did not differ between the three conditions. However, increased internal sensory monitoring coincided with elevated effort perceptions in some subjects during EC and a 10% slower completion time for PE (13.0 ± 1.6 min) than that for SC (11.8 ± 1.2 min). Altering pace control and pace regulation impacted on attentional focus. External control over pacing may facilitate performance, particularly when runners engage attentional strategies conducive to improved running efficiency. However, regulating pace based on effort perceptions alone may result in excessive monitoring of bodily sensations and a slower running speed. Accordingly, attentional focus interventions may prove beneficial for some athletes to adopt task-appropriate attentional strategies to optimize performance.

  3. Inferring microbial interaction networks from metagenomic data using SgLV-EKF algorithm.

    Science.gov (United States)

    Alshawaqfeh, Mustafa; Serpedin, Erchin; Younes, Ahmad Bani

    2017-03-27

    Inferring the microbial interaction networks (MINs) and modeling their dynamics are critical in understanding the mechanisms of the bacterial ecosystem and designing antibiotic and/or probiotic therapies. Recently, several approaches were proposed to infer MINs using the generalized Lotka-Volterra (gLV) model. Main drawbacks of these models include the fact that these models only consider the measurement noise without taking into consideration the uncertainties in the underlying dynamics. Furthermore, inferring the MIN is characterized by the limited number of observations and nonlinearity in the regulatory mechanisms. Therefore, novel estimation techniques are needed to address these challenges. This work proposes SgLV-EKF: a stochastic gLV model that adopts the extended Kalman filter (EKF) algorithm to model the MIN dynamics. In particular, SgLV-EKF employs a stochastic modeling of the MIN by adding a noise term to the dynamical model to compensate for modeling uncertainties. This stochastic modeling is more realistic than the conventional gLV model which assumes that the MIN dynamics are perfectly governed by the gLV equations. After specifying the stochastic model structure, we propose the EKF to estimate the MIN. SgLV-EKF was compared with two similarity-based algorithms, one algorithm from the integral-based family and two regression-based algorithms, in terms of the achieved performance on two synthetic data-sets and two real data-sets. The first data-set models the randomness in measurement data, whereas, the second data-set incorporates uncertainties in the underlying dynamics. The real data-sets are provided by a recent study pertaining to an antibiotic-mediated Clostridium difficile infection. The experimental results demonstrate that SgLV-EKF outperforms the alternative methods in terms of robustness to measurement noise, modeling errors, and tracking the dynamics of the MIN. Performance analysis demonstrates that the proposed SgLV-EKF algorithm

  4. Positive pacing in elite IRONMAN triathletes.

    Science.gov (United States)

    Angehrn, Nicole; Rüst, Christoph A.; Nikolaidis, Pantelis T.; Rosemann, Thomas; Knechtle, Beat

    2016-12-31

    Pacing is known to influence athletic performance. For the Ironman triathlon program, a positive pacing strategy, i.e., the continuous decrease of speed over time was recommended. By analyzing split times, we assessed the pacing strategies of the top 100 finishers of the cycling part of 13 Ironman races and of the running part of 11 Ironman races taking place in 2014. Furthermore, sex-associated differences in performance and pacing strategies were calculated. We analyzed 7,687 cycling and 11,894 running split times of 1,392 triathletes (1,263 men, 129 women). Changes in speed were assessed using mixed-effects regression analyses. A continuous decrease in speed was observed during cycling in 10/13 races, and during running in 11/11 races. In 6/13 races, women decreased their speed during cycling significantly more than men. The running part showed no significant difference of changes in speed between the sexes. In summary, in the Ironman races evaluated, a positive pacing strategy was adopted in most races. Women were slower than men in 6/13 cycling races, but there was no difference between men and women in the run splits. Women used the same pacing strategy as men.

  5. Efficient Control of Energy Storage for Increasing the PV Hosting Capacity of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob

    2016-01-01

    grid is usually limited by overvoltage, and the efficient control of distributed electrical energy storage systems (EESSs) can considerably increase this capacity. In this paper, a new control approach based on the voltage sensitivity analysis is proposed to prevent overvoltage and increase the PV......Photovoltaic (PV) systems are among the renewable sources that electrical energy systems are adopting with increasing frequency. The majority of already-installed PV systems are decentralized units that are usually connected to lowvoltage (LV) distribution grids. The PV hosting capacity of an LV...... hosting capacity of LV grids by determining dynamic set points for EESS management. The method has the effectiveness of central control methods and can effectively decrease the energy storage required for overvoltage prevention, yet it eliminates the need for a broadband and fast communication. The net...

  6. EV Charging Facilities and Their Application in LV Feeders with Photovoltaics

    DEFF Research Database (Denmark)

    Marra, Francesco; Yang, Guangya; Træholt, Chresten

    2013-01-01

    Low-voltage (LV) grid feeders with high penetration of photovoltaics (PVs) are often affected by voltage magnitude problems. To solve such issues, previous research has shown that reactive power methods, active power curtailment and grid reinforcement can be used for voltage support, yet showing...... several limits. We introduce the use of electric vehicle (EV) public charging stations with energy storage system (ESS) as a solution for voltage regulation in LV feeders with PV. A novel method is proposed to determine the ESS charging load required for voltage regulation and compare the results...... for the different locations in the feeder. With time-series simulations, we quantify the energy size required for a station ESS. A Belgian LV residential grid, modeled using real PV generation and load profiles, is used as case study. The method and simulation results show the effectiveness of using public EV...

  7. The Managed Ventricular pacing versus VVI 40 Pacing (MVP) Trial: clinical background, rationale, design, and implementation.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Miller, Elaine Hogan; Sherfesee, Lou; Sheldon, Todd; Whellan, David

    2006-12-01

    Implantable cardioverter defibrillators (ICDs) reduce mortality among appropriately selected patients who have had or are at risk for life-threatening ventricular arrhythmia. Right ventricular apical (RVA) pacing has been implicated in worsening heart failure and death. The optimal pacemaker mode for bradycardia support while minimizing unnecessary and potentially harmful RVA pacing has not been determined. The Managed Ventricular pacing vs. VVI 40 Pacing Trial (MVP) is a prospective, multicenter, randomized, single-blind, parallel, controlled clinical trial designed to establish whether atrial-based dual-chamber managed ventricular pacing mode (MVP) is equivalent or superior to back-up only ventricular pacing (VVI 40) among patients with standard indications for ICD therapy and no indication for bradycardia pacing. The MVP Trial is designed with 80% power to detect a 10% reduction in the primary endpoint of new or worsening heart failure or all-cause mortality in the MVP-treated group. Approximately 1,000 patients at 80 centers in the United States, Canada, Western Europe, and Israel will be randomized to MVP or VVI 40 pacing after successful implantation of a dual-chamber ICD. Heart failure therapies will be optimized in accordance with evidence-based guidelines. Prespecified secondary endpoints will include ventricular arrhythmias, atrial fibrillation, new indication for bradycardia pacing, health-related quality of life, and cost effectiveness. Enrollment began in October 2004 and concluded in April 2006. The study will be terminated upon recommendation of the Data Monitoring Committee or when the last patient enrolled and surviving has reached a minimum 2 years of follow-up. The MVP Trial will meet the clinical need for carefully designed prospective studies to define the benefits of atrial-based dual-chamber minimal ventricular pacing versus single-chamber ventricular pacing in conventional ICD patients.

  8. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    Directory of Open Access Journals (Sweden)

    Domenico Santarsiero

    2008-03-01

    Full Text Available The Applanix POS/LV platform in cinematic laser scanner applicationsOn the 11th of march the GEOmedia editorial unit had the pleasure of hosting a technical meeting dedicated to the Applanix LANDMark new Position and Orientation System for Land Vehicles (POS/LVfield test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products and Terenzio Mariani (Sales manager for Italy, helped to test the functionalities of a complete POS/LV system equipped with a laser and an imaging acquisition software installed on board of a SUV.

  9. Pacing in Swimming: A Systematic Review.

    Science.gov (United States)

    McGibbon, Katie E; Pyne, D B; Shephard, M E; Thompson, K G

    2018-03-20

    Pacing strategy, or how energy is distributed during exercise, can substantially impact athletic performance and is considered crucial for optimal performance in many sports. This is particularly true in swimming given the highly resistive properties of water and low mechanical efficiency of the swimming action. The aim of this systematic review was to determine the pacing strategies utilised by competitive swimmers in competition and their reproducibility, and to examine the impact of different pacing strategies on kinematic, metabolic and performance variables. This will provide valuable and practical information to coaches and sports science practitioners. The databases Web of Science, Scopus, SPORTDiscus and PubMed were searched for published articles up to 1 August 2017. A total of 23 studies examining pool-based swimming competitions or experimental trials in English-language and peer-reviewed journals were included in this review. In short- and middle-distance swimming events maintenance of swimming velocity is critical, whereas in long-distance events a low lap-to-lap variability and the ability to produce an end spurt in the final lap(s) are key. The most effective strategy in the individual medley (IM) is to conserve energy during the butterfly leg to optimise performance in subsequent legs. The pacing profiles of senior swimmers remain relatively stable irrespective of opponents, competition stage or type, and performance time. Implementing event-specific pacing strategies should benefit the performance of competitive swimmers. Given differences between swimmers, there is a need for greater individualisation when considering pacing strategy selection across distances and strokes.

  10. Integration of SPICE with TEK LV500 ASIC Design Verification System

    Directory of Open Access Journals (Sweden)

    A. Srivastava

    1996-01-01

    Full Text Available The present work involves integration of the simulation stage of design of a VLSI circuit and its testing stage. The SPICE simulator, TEK LV500 ASIC Design Verification System, and TekWaves, a test program generator for LV500, were integrated. A software interface in ‘C’ language in UNIX ‘solaris 1.x’ environment has been developed between SPICE and the testing tools (TekWAVES and LV500. The function of the software interface developed is multifold. It takes input from either SPICE2G.6 or SPICE 3e.1. The output generated by the interface software can be given as an input to either TekWAVES or LV500. A graphical user interface has also been developed with OPENWlNDOWS using Xview tool kit on SUN workstation. As an example, a two phase clock generator circuit has been considered and usefulness of the software demonstrated. The interface software could be easily linked with VLSI design such as MAGIC layout editor.

  11. 77 FR 21620 - Notice of the Buy America Waiver Request for Vossloh 101-LV Concrete Ties

    Science.gov (United States)

    2012-04-10

    ... the Buy America Waiver Request for Vossloh 101-LV Concrete Ties AGENCY: Federal Railroad... concrete ties, which contain certain components not manufactured in the United States. In furtherance of... concrete ties. FRA has received this request from the four States for the following projects: (a) The...

  12. Extinction in the Galaxy from surface brightnesses of ESO-LV galaxies : Testing "standard" extinction maps

    NARCIS (Netherlands)

    Choloniewski, J.; Valentijn, E. A.

    A new method for the determination of the extinction in the Galaxy is proposed. The method uses surface brightnesses of external galaxies in the B and R-bands. The observational data have been taken from the ESO-LV galaxy catalog. As a first application of our model we derive the ratio of R-band to

  13. Current distribution in LV networks during 1-phase MV short-circuit

    NARCIS (Netherlands)

    Waes, van J.B.M.; Provoost, F.; Merwe, van der J.; Cobben, J.F.G.; Deursen, van A.P.J.; van Riet, M.J.M.; Laan, van der P.C.T.

    2000-01-01

    This paper describes the consequences of a fault in a medium voltage network on the grounding systems at the LV-side. To study the current distribution and to verify the models, we deliberately introduced one phase to ground faults in the 10 kV floating MV network. The selected site was the end of a

  14. La piattaforma POS/LV di Applanix nelle applicazioni di laser scanner cinematico

    Directory of Open Access Journals (Sweden)

    Domenico Santarsiero

    2008-03-01

    field test. The meeting, which is part of an italian tour organized by Louis Nastro (Applanix Director of Land Products and Terenzio Mariani (Sales manager for Italy, helped to test the functionalities of a complete POS/LV system equipped with a laser and an imaging acquisition software installed on board of a SUV.

  15. Distributed generation in the Dutch LV network - self-supporting residential area

    NARCIS (Netherlands)

    Mes, M.; Vanalme, G.M.A.; Myrzik, J.M.A.; Bongaerts, M.; Verbong, G.P.J.; Kling, W.L.

    2008-01-01

    A self-supporting residential area is seen as an alternative operational approach of power supply in low voltage (LV) networks. The intention of the new approach is to exploit the advantages of distributed generation (DG) and avoid the difficulties, that come with DG when implemented in the

  16. Agent-based unified approach for thermal and voltage constraint management in LV distribution network

    NARCIS (Netherlands)

    Haque, A.N.M.M.; Nguyen, H.P.; Vo, T.; Bliek, F.W.

    2016-01-01

    Rapid proliferation of the distributed energy resources (DERs) poses operational challenges for the low-voltage (LV) distribution networks in terms of thermal overloading of the network assets along with voltage limit violations at the connection points. A number of market-based and direct control

  17. Coordinated control to mitigate over voltage and under voltage in LV networks

    NARCIS (Netherlands)

    Viyathukattuva Mohamed Ali, M.M.; Nguyen, H.P.; Cobben, J.F.G.

    2016-01-01

    Increasing penetration of distributed renewable energy resources (DRES) and smart loads into the LV network lead to new power quality challenges. Important power quality challenges are overvoltage and undervoltage. A number of solutions are already developed to mitigate these voltage variations. In

  18. Diastolic And Systolic Right Ventricular Dysfunction Precedes Left Ventricular Dysfunction In Patients Paced From Right Ventricular Apex

    Directory of Open Access Journals (Sweden)

    Dwivedi SK

    2006-07-01

    Full Text Available Background: Cardiac dysfunction after right ventricular (RV apical pacing is well known but its extent, time frame of appearance and individual effect on left ventricular (LV, RV systolic and diastolic parameters has not evaluated in a systematic fashion. Methods: Patients with symptomatic bradycardia and ACC-AHA Class I indication for permanent pacemaker implantation (PPI were implanted a single chamber (VVI pacemaker. They were followed prospectively by echocardiographic examination which was done at baseline, 1 week, 1 month and 6 months after implantation. Parameters observed were chamber dimensions (M-line, chamber volumes, cardiac output (modified Simpson's method, systolic functions (ejection fraction, pre-ejection period, ejection time and ratio and diastolic functions( isovolumic relaxation time & deceleration time of left and right heart. Results: Forty eight consecutive patients (mean age 65.6±11.8 yrs, 66.7% males, mean EF 61.82±10.36% implanted a VVI pacemaker were enrolled in this study. The first significant change to appear in cardiac function after VVI pacing was in diastolic properties of RV as shown by increase in RV isovolumic relaxation time (IVRT from 65.89±15.93 to 76.58±17.00 ms,(p<0.001 at 1week and RV deceleration time (DT from 133.84±38.13 to 153.09±31.41 ms, (p=0.02 at 1 month. Increase in RV internal dimension (RVID from 1.26±0.41 to 1.44±0.44, (p<0.05 was also noticed at 1 week. The LV diastolic parameters were significantly altered after 1 month with increase in LV-IVRT from 92.36±21.47 to 117.24±27.21ms, (p<0.001 and increase in LV DT from 147.56±31.84 to 189.27±28.49ms,(p<0.01. This was followed by LV systolic abnormality which appeared at 6 months with an increase in LVPEP from 100.33±14.43 to 118.41±21.34ms, (p<0.001 and increase in LVPEP/LVET ratio from 0.34±0.46 to 0.44±0.10, (p<0.001]. The reduction in LV EF was manifested at 6 months falling from 61.82±10.36% to52.52±12.11%, (p<0

  19. How do we perceive activity pacing in rheumatology care?

    DEFF Research Database (Denmark)

    Cuperus, N.; Vliet Vlieland, T.; Brodin, N.

    2015-01-01

    goals of activity pacing, behaviours of activity pacing (the actions people take to meet the goal of activity pacing), strategies to change behaviour in activity pacing (for example goal setting) and contextual factors that should be acknowledged when instructing activity pacing. Besides, topics......-management programs. However, despite its wide endorsement in clinical practice, to date activity pacing is still a poorly understood concept. Objectives: To achieve consensus by means of an international Delphi exercise on the most important aspects of activity pacing as an intervention within non...... for future research on activity pacing were formulated and prioritized. Results: Of the 60 panelists, nearly two third (63%) completed all four Delphi rounds. The panel prioritized 9 goals, 11 behaviours, 9 strategies to change behaviour and 10 contextual factors of activity pacing. These items were...

  20. Self-Paced Instruction: Hello, Education

    Science.gov (United States)

    Leuba, Richard J.; Flammer, Gordon H.

    1975-01-01

    Answers criticisms of self-paced instruction (SPI) by citing advantages of SPI over lecture methods. Concludes that criticisms of SPI are useful since they indicate in which areas further research should be conducted to improve this method of instruction. (MLH)

  1. The Platform-Aware Compilation Environment (PACE)

    Science.gov (United States)

    2012-09-01

    The PACE Project provided full or partial support for the following graduate students: 1. Raj Barik (Rice) 2. Thomas Barr (Rice) 3...University, Houston, TX, Technical Report CS TR11-03, October 20, 2011. [7] Rajkishore Barik , Jisheng Zhao, and Vivek Sarkar, "Efficient Selection

  2. The pace and shape of ageing

    DEFF Research Database (Denmark)

    Baudisch, Annette

    2011-01-01

    exhibits negligible ageing - contrary to the commonly held view that long-lived species are good candidates for negligible ageing. 5.Analysis of species in pace-shape space provides a tool to identify key determinants of the evolution of ageing for species across the tree of life....

  3. Potenzielle Einflussfaktoren auf Pacing im ausdauersportlichen Wettkampf

    NARCIS (Netherlands)

    Thiel, C.; de Koning, J.J.; Foster, C.

    2015-01-01

    In competitive endurance sport, athletes permanently regulate their performance to achieve the best result without threatening organismic integrity. This conscious and subconscious allocation of energy reserves in relation to an endpoint is termed pacing and depends on sport-specific experience as

  4. Effect of biventricular pacing on heart function evaluated by gated blood pool study in patients with end-stage heart failure

    International Nuclear Information System (INIS)

    Cholewinski, W.; Tarkowska, A.; Stefaniak, B.; Poniatowicz-Frasunek, E.; Kutarski, A.; Oleszczak, K.

    2002-01-01

    Biventricular cardiac pacing has been used as a complementary form of therapy in patients with severe heart failure. The aim of this study was to evaluate the effect of the synchronous stimulation of both ventricles on the heart function measured by gated blood pool study (GBP). Ten patients (9 men and 1 woman aged 53-74 years) with end-stage heart failure (HF) were studied. In all patients long-term biventricular pacing (BV) was applied. The obtained results were compared with single-chamber stimulation in 5 patients and with sinus rhythm (SR) in 8 patients. All patients underwent repeated GBP with RBC labelled with 740 MBq of 99m Tc-pertechnetate. The LVEF was calculated according to the standard method based on the count rates. Phase analysis was performed with the standard method using first Fourier element. Clinically in almost all patients moderate to important symptomatic improvement has been observed. The analysis of LVEF values revealed that BV pacing resulted in significantly higher values only in comparison with SR (21.6% ±10.3 v. 20.1% ± 10.1; p o± 29.6 v. 13.4 o± 37.6 and 7.4 o± 26.5 v. 6.0 o± 17.1, respectively). However, in comparison with LV pacing, BV stimulation revealed a change of dominant conduction abnormalities with a delay of RV contraction in relation to LV (9.0 o± 17.5 v. -3.0 o± 11.4). Biventricular pacing results in slight improvement of LVEF in patients with heart failure and can be considered a promising approach in patients with end-stage heart failure. Synchronous stimulation of both ventricles not always results in decrease of interventricular shift, however that observation requires further studies on a larger population. (author)

  5. Large animal model of functional tricuspid regurgitation in pacing induced end-stage heart failure.

    Science.gov (United States)

    Malinowski, Marcin; Proudfoot, Alistair G; Langholz, David; Eberhart, Lenora; Brown, Michael; Schubert, Hans; Wodarek, Jeremy; Timek, Tomasz A

    2017-06-01

    Functional tricuspid regurgitation (FTR) is common in patients with advanced heart failure and frequently complicates left ventricular assist device implantation yet remains poorly understood. We set out to establish large animal model of FTR that could serve as a research platform to investigate the pathogenesis of FTR associated with end-stage heart failure. : Through right thoracotomy, ten adult sheep underwent implantation of pacemaker with epicardial LV lead, five sonomicrometry crystals on the right ventricle, and left and right ventricular telemetry pressure sensors during a beating heart off-pump procedure. After 5 ± 1 days of recovery, baseline haemodynamic, echocardiographic and sonomicrometry data were collected. Animals were paced thereafter at a rate of 220-240 beats/min until the development of heart failure and concomitant tricuspid regurgitation. : Three animals died during early recovery period and one during the pacing phase. Six surviving animals were paced for a mean of 14 ± 5 days. Cardiac function was significantly depressed compared to baseline, with LV ejection fraction falling from 69 ± 2% to 22 ± 4% ( P  tricuspid annulus (from 29.5 ± 1.6 to 36.5 ± 4.5 mm; P  = 0.01) and right ventricle (from 21.9 ± 0.2 to 30.3 ± 0.6 mm; P  = 0.03). Sonomicrometry derived contractility of RV free wall was depressed and at least moderate tricuspid insufficiency developed in all animals. : Biventricular dysfunction, tricuspid annular dilatation and significant FTR were observed in our model of ovine tachycardia induced cardiomyopathy. This animal model reflects the clinical situation of end-stage heart failure patients presenting for mechanical support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Resistance to RadLV-induced leukemia: non-participation of splenic natural killer cells

    International Nuclear Information System (INIS)

    St-Pierre, Y.; Hugo, P.; Lemieux, S.; Lussier, G.; Potworowski, E.F.

    1988-01-01

    The phenotypic expression of genetically determined resistance to radiation leukemia virus (RadLV)-induced leukemia in mice has been shown to reside in the bone marrow. Because the bone marrow contains precursors of natural killer (NK) cells, known to play a role in retrovirally induced infections, and because these cells have been suggested as participating in resistance to radiation-induced leukemia, it was pertinent to establish whether their levels differed in strains of mice susceptible and resistant to leukemia. We therefore tested splenic NK cell levels in C57BL/Ka (susceptible) and B10.A(5R) (resistant) mice before viral inoculation, immediately after viral inoculation, and throughout the preleukemic period and showed that they were not different. This indicates that splenic NK cell levels have no bearing on the resistance to RadLV-induced leukemia and that other immune or non-immune mechanisms must be sought

  7. Seismic monitoring during acid stimulation of wells LV-4 and LV-13 at the Las Tres Virgenes geothermal field, BCS, Mexico; Monitoreo sismico durante la estimulacion acida de los pozos LV-4 y LV-13 del campo geotermico de Las Tres Virgenes, BCS, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Venegas Salgado, Saul; Arredondo Fragoso, Jesus; Ramirez Silva, German; Flores Armenta, Magaly; Ramirez Montes, Miguel [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)]. E-mail: magaly.flores@cfe.gob.mx

    2006-07-15

    From September through December 2004 a seismic monitoring in the Las Tres Virgenes, BCS, geothermal field was carried out simultaneously with the acid stimulation of wells LV-4 and LV-13. The seismic network had four digital seismographs and recorded 174 local seismic events, 131 regional ones and many more volcanic signals at seismic station TV20 during the acid stimulation. Additionally, 37 seismic events were located, 22 of them inside the most important geothermal zone at depths between 0.4 and 4 km with typically low magnitudes (0.7 to 2.2 Md). Two relevant zones were determined: Zone A related to the El Volcan fault system and Zone B related to injection well LV-8. In Zone A the well-induction stage and the operation start of the wells LV-4 and LV-13 after acidification on October 30 and November 17, 2004, increased seismic activity to a maximum of 12 daily events in early December. When the two wells in Zone B were cooled before the acidification, the seismic events recorded there increased to a maximum of 6 daily events on October 2, and then decreased. Also in Zone B the seismic activity increased after well-induction and the start of well production once they were acidified, recording up to 11 daily events in late November. According to the seismic distribution, we may conclude that the most active fault systems are El Volcan and El Viejo. New proposals for well locations in the field are supported by these results. [Spanish] De septiembre a diciembre de 2004 se realizo un estudio de monitoreo sismico en el campo geotermico de Las Tres Virgenes, BCS, simultaneamente con las estimulaciones acidas de los pozos LV-4 y LV-13. Se utilizo una red sismica conformada por cuatro sismografos digitales, logrando registrar en la estacion sismica TV20 un total de 174 sismos locales, 131 sismos regionales y muchas mas senales de tipo volcanico, durante el periodo del monitoreo de la estimulacion acida. Ademas, se localizaron un total de 37 sismos, de los cuales 22 se

  8. Study on the overcurrent character analysis and its protective system of underground LV distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.; Shi, Z.; Yang, Y.; Shi, W.; Wei, H.; Zhai, S.; Xie, H. [Taiyuan University of Technology, Taiyuan (China)

    2001-02-01

    The overcurrent fault characteristics in underground LV cable distribution networks is analysed and the fundamental principle of overcurrent protective system is described in this paper. The emphasis is paid to the determination of the characteristic curves of phase-sensitive symmetrical short-circuit protection, the design of negative-sequence current filter and the definition of the mathematical model of overload. Besides, the hardware block diagram and the software flowchart of the protective system, which is controlled by a single chip microcomputer, is also introduced in the paper. The protective system was tested before being applied to the underground LV distribution networks. The results obtained are in conformity with the design specification. It has been verified that the protective distance is extended and the protective sensitivity is improved with the protective system. The field experience has shown that the protective system is stable and reliable, and will be of great application value in the mining industry. 7 refs., 5 figs., 2 tabs.

  9. Drift of IBL LV current and its consequence in IBL distortion

    CERN Document Server

    The ATLAS collaboration

    2015-01-01

    The low voltage (LV) current of the IBL modules had been stable since the beginning of the Run2 until the middle of September 2015, but it has been unstable since then (Figure 1). A clear relation is observed between the current rise-up and the total radiation doze (TID) increase, which is considered to be the TID effect reported in . A shutdown of more than 29 hour on October 6 recovered the current largely (Figure 2). With the change of the LV current, the temperature of IBL modules also changes (Figure 3). The change of the thermo-mechanical condition of the IBL resulted in the change of the IBL distortion magnitude, and a clear relation between the module temperature and the distortion magnitude is observed (Figure 4). Through the duration presented in this series of plots, the cooling set temperature of the IBL was kept at -10℃.

  10. Development of conductor feedthrough module of LV electrical penetration assembly for research reactors

    International Nuclear Information System (INIS)

    Luo Zhiyuan; Wang Guangjin; Zhou Bin

    2007-01-01

    A LV electrical penetration assembly with perfusion sealing conductor feedthrough module was developed, which can be used for the connection of internal and external cables through the wall of the research reactor workshop. The LV electrical penetration assembly was combined with several independent modules. The maintenance and replacement of the assembly can be easily done in service. The sealing of conductor feedthrough module was achieved with the perfusion of self-extinguishing epoxy. The leakage between the conductor feedthrough module and the end plate module was blocked with rubber rings. The result of the leakage test and the electrical performance test for the samples of conductor feedthrough module satisfied the requirement of research reactor. The structure of the new electrical penetration assembly is simple and compact. It can be manufactured with mature technology and cost low price. The performance of the assembly is steady. It can be used widely in research reactors. (authors)

  11. Analysis of critical operating conditions for LV distribution networks with microgrids

    Science.gov (United States)

    Zehir, M. A.; Batman, A.; Sonmez, M. A.; Font, A.; Tsiamitros, D.; Stimoniaris, D.; Kollatou, T.; Bagriyanik, M.; Ozdemir, A.; Dialynas, E.

    2016-11-01

    Increase in the penetration of Distributed Generation (DG) in distribution networks, raises the risk of voltage limit violations while contributing to line losses. Especially in low voltage (LV) distribution networks (secondary distribution networks), impacts of active power flows on the bus voltages and on the network losses are more dominant. As network operators must meet regulatory limitations, they have to take into account the most critical operating conditions in their systems. In this study, it is aimed to present the impact of the worst operation cases of LV distribution networks comprising microgrids. Simulation studies are performed on a field data-based virtual test-bed. The simulations are repeated for several cases consisting different microgrid points of connection with different network loading and microgrid supply/demand conditions.

  12. Lv Peng and his Chinese Art History in Operation, since 1986’

    Directory of Open Access Journals (Sweden)

    Joshua Gong

    2014-06-01

    Full Text Available Lv Peng is one of the most influential contemporary Chinese art historians, who began publishing his work in 1986 and introduced various innovative approaches and methods to the field. Even though his work gained momentum in the field, his totalising and continually-revised publication scheme have come under incessant criticism from friends and rivals alike. This article is an attempt at surveying Lv Peng’s oeuvre, while testifying to the value of his art history writings by making his various approaches more legible and systematic. His most popular publications as well as a few projects that are still in progress will be analysed for a more comprehensive understanding of his operational art history.

  13. Voltage unbalance mitigation in LV networks using three-phase PV systems

    DEFF Research Database (Denmark)

    Garcia Bajo, Cristina; Hashemi Toghroljerdi, Seyedmostafa; Bækhøj Kjær, Søren

    2015-01-01

    In this paper a new method is proposed to mitigate voltage unbalance caused by single-phase solar inverters in low voltage (LV) networks. The method is based on uneven reactive power absorption and injection by three-phase solar inverters. Independent control of each phase is performed to achieve...... this uneven injection. The average values of phase voltages at the connection points of the photovoltaic (PV) inverters are used as the references for the balancing algorithm. Voltage unbalance mitigation is achieved by use of this method in different scenarios with variable three-phase and single......-phase inverters penetration in a realistic LV grid. In addition, the overvoltage is reduced by using this method....

  14. A New Protection System for Islanding Detection in LV Distribution Systems

    Directory of Open Access Journals (Sweden)

    Anna Rita Di Fazio

    2015-04-01

    Full Text Available The growth of penetration of Distributed Generators (DGs is increasing the risk of unwanted islanded operation in Low Voltage (LV distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match between generation and load. In this paper, a new protection system for islanding detection in LV distribution systems is proposed. The classical voltage and frequency relays in the DG interface protections are enriched with an innovative Smart Islanding Detector, which adopts a new passive islanding detection method. The aim is to keep the advantages of the classical relays while overcoming the problem of their limited sensitivity in detecting balanced islands. In the paper, to define the requirements of the anti-islanding protection system, the events causing the islanded operation of the LV distribution systems are firstly identified and classified. Then, referring to proposed protection system, its architecture and operation are described and, eventually, its performance is analyzed and validated by experimental laboratory tests, carried out with a hardware-in-the-loop technique.

  15. Quantifying grain shape with MorpheoLV: A case study using Holocene glacial marine sediments

    Science.gov (United States)

    Charpentier, Isabelle; Staszyc, Alicia B.; Wellner, Julia S.; Alejandro, Vanessa

    2017-06-01

    As demonstrated in earlier works, quantitative grain shape analysis has revealed to be a strong proxy for determining sediment transport history and depositional environments. MorpheoLV, devoted to the calculation of roughness coefficients from pictures of unique clastic sediment grains using Fourier analysis, drives computations for a collection of samples of grain images. This process may be applied to sedimentary deposits assuming core/interval/image archives for the storage of samples collected along depth. This study uses a 25.8 m jumbo piston core, NBP1203 JPC36, taken from a 100 m thick sedimentary drift deposit from Perseverance Drift on the northern Antarctic Peninsula continental shelf. Changes in ocean and ice conditions throughout the Holocene recorded in this sedimentary archive can be assessed by studying grain shape, grain texture, and other proxies. Ninety six intervals were sampled and a total of 2319 individual particle images were used. Microtextures of individual grains observed by SEM show a very high abundance of authigenically precipitated silica that obscures the original grain shape. Grain roughness, computed along depth with MorpheoLV, only shows small variation confirming the qualitative observation deduced from the SEM. Despite this, trends can be seen confirming the reliability of MorpheoLV as a tool for quantitative grain shape analysis.

  16. Quantifying grain shape with MorpheoLV: A case study using Holocene glacial marine sediments

    Directory of Open Access Journals (Sweden)

    Charpentier Isabelle

    2017-01-01

    Full Text Available As demonstrated in earlier works, quantitative grain shape analysis has revealed to be a strong proxy for determining sediment transport history and depositional environments. MorpheoLV, devoted to the calculation of roughness coefficients from pictures of unique clastic sediment grains using Fourier analysis, drives computations for a collection of samples of grain images. This process may be applied to sedimentary deposits assuming core/interval/image archives for the storage of samples collected along depth. This study uses a 25.8 m jumbo piston core, NBP1203 JPC36, taken from a ~100 m thick sedimentary drift deposit from Perseverance Drift on the northern Antarctic Peninsula continental shelf. Changes in ocean and ice conditions throughout the Holocene recorded in this sedimentary archive can be assessed by studying grain shape, grain texture, and other proxies. Ninety six intervals were sampled and a total of 2319 individual particle images were used. Microtextures of individual grains observed by SEM show a very high abundance of authigenically precipitated silica that obscures the original grain shape. Grain roughness, computed along depth with MorpheoLV, only shows small variation confirming the qualitative observation deduced from the SEM. Despite this, trends can be seen confirming the reliability of MorpheoLV as a tool for quantitative grain shape analysis.

  17. Pace of work stabilising, but not in all sectors

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2003-01-01

    The Netherlands had the highest level of work pace in Europe but this position has levelled off in the last five years. There appears to be a general trend towards a decline in work pace. However, different sectors show varying trends, with work pace on the rise again in the education, health and

  18. Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study.

    Science.gov (United States)

    Siciliano, Mariachiara; Migliore, Federico; Badano, Luigi; Bertaglia, Emanuele; Pedrizzetti, Gianni; Cavedon, Stefano; Zorzi, Alessandro; Corrado, Domenico; Iliceto, Sabino; Muraru, Denisa

    2017-11-01

    To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). In 11 consecutive patients [8 men; median age 65 years (57-75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base-apex direction, up to 90° when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P = 0.02; P = 0.008, respectively) and BiV (P = 0.04; P = 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P = 0.008; P = 0.008; P = 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRT-OFF and BiV (P = 0.002) indicating a systematic increase of longitudinal alignment from the base-apex orientation of the haemodynamic forces. These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis. © Crown copyright 2016.

  19. Visual aided pacing in respiratory maneuvers

    Energy Technology Data Exchange (ETDEWEB)

    Rambaudi, L R [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Rossi, E [Catedra de Bioingenieria II (Argentina); Mantaras, M C [Catedra de Bioingenieria II (Argentina); Perrone, M S [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Siri, L Nicola [Catedra de Bioingenieria II (Argentina)

    2007-11-15

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display.

  20. Visual aided pacing in respiratory maneuvers

    International Nuclear Information System (INIS)

    Rambaudi, L R; Rossi, E; Mantaras, M C; Perrone, M S; Siri, L Nicola

    2007-01-01

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display

  1. Transient Response and Steady-State Analysis of the Anode of Direct Methanol Fuel Cells Based on Dual-Site Kinetics

    Directory of Open Access Journals (Sweden)

    Lei Xing

    2011-01-01

    Full Text Available An intrinsic time-dependent one-dimensional (1D model and a macro two-dimensional (2D model for the anode of the direct methanol fuel cell (DMFC are presented. The two models are based on the dual-site mechanism, which includes the coverage of intermediate species of methanol, OH, and CO (θM, θOH,Ru, and θCO,Pt on the surface of Pt and Ru. The intrinsic 1D model focused on the analysis of the effects of operating temperature, methanol concentration, and overpotential on the transient response. The macro 2D model emphasises the dimensionless distributions of methanol concentration, overpotential and current density in the catalyst layer which were affected by physical parameters such as thickness, specific area, and operating conditions such as temperature, bulk methanol concentration, and overpotential. The models were developed and solved in the PDEs module of COMSOL Multiphysics, giving good agreement with experimental data. The dimensionless distributions of methanol concentration, overpotential, and current density and the efficiency factor were calculated quantitatively. The models can be used to give accurate simulations for the polarisations of methanol fuel cell.

  2. Envelope Proteins of White Spot Syndrome Virus (WSSV Interact with Litopenaeus vannamei Peritrophin-Like Protein (LvPT.

    Directory of Open Access Journals (Sweden)

    Shijun Xie

    Full Text Available White spot syndrome virus (WSSV is a major pathogen in shrimp cultures. The interactions between viral proteins and their receptors on the surface of cells in a frontier target tissue are crucial for triggering an infection. In this study, a yeast two-hybrid (Y2H library was constructed using cDNA obtained from the stomach and gut of Litopenaeus vannamei, to ascertain the role of envelope proteins in WSSV infection. For this purpose, VP37 was used as the bait in the Y2H library screening. Forty positive clones were detected after screening. The positive clones were analyzed and discriminated, and two clones belonging to the peritrophin family were subsequently confirmed as genuine positive clones. Sequence analysis revealed that both clones could be considered as the same gene, LV-peritrophin (LvPT. Co-immunoprecipitation confirmed the interaction between LvPT and VP37. Further studies in the Y2H system revealed that LvPT could also interact with other WSSV envelope proteins such as VP32, VP38A, VP39B, and VP41A. The distribution of LvPT in tissues revealed that LvPT was mainly expressed in the stomach than in other tissues. In addition, LvPT was found to be a secretory protein, and its chitin-binding ability was also confirmed.

  3. Leadless Pacing: Current State and Future Direction.

    Science.gov (United States)

    Merkel, Matthias; Grotherr, Philipp; Radzewitz, Andrea; Schmitt, Claus

    2017-12-01

    Leadless pacing is now an established alternative to conventional pacing with subcutaneous pocket and transvenous lead for patients with class I or II single-chamber pacing indication. Available 12-month follow-up data shows a 48% fewer major complication rate in patients with Micra™ compared to a historical control group in a nonrandomized study [1]. There is one system with Food and Drug Administration (FDA) approval and two with the Communauté Européenne (CE) mark. The OPS code for the implantation is 8-83d.3 and the procedure has recently been rated as a "new Examination and Treatment Method (NUB)" in the German DRG system, meaning adequate reimbursement is negotiable with health insurance providers. The systems offer similar generator longevity and programming possibilities as conventional pacemaker systems, including rate response, remote monitoring, and MRI safety. The biggest downsides to date are limitations to single-chamber stimulation, lack of long-time data, and concerns of handling of the system at the end of its life span. However, implant procedure complication rates and procedure times do not exceed conventional pacemaker operations, and proper training and patient selection is provided.

  4. Temporary emergency pacing-an orphan in district hospitals

    DEFF Research Database (Denmark)

    Gjesdal, Knut; Johansen, Jens Brock; Gadler, Fredrik

    2012-01-01

    This editorial discusses a report on the 1 year experience with temporary pacing, especially in the emergency setting, in several Norwegian district hospitals. The vast majority of the patients received transvenous temporary pacing, and the majority of leads were placed by noncardiologists....... The procedure times were long and complications were frequent. The organization of emergency pacing is discussed, and we suggest that unless qualified physicians can establish transvenous pacing, the patients who need that should be transferred with transcutaneous pacing as back-up during transport...

  5. Viral Determinants of FeLV Infection and Pathogenesis: Lessons Learned from Analysis of a Natural Cohort

    Directory of Open Access Journals (Sweden)

    Laura S. Levy

    2011-09-01

    Full Text Available Detailed analysis has been performed over many years of a geographic and temporal cohort of cats naturally infected with feline leukemia virus (FeLV. Molecular analysis of FeLV present in the diseased tissues and application of those viruses to experimental systems has revealed unique isolates with distinctive disease potential, previously uncharacterized virus-receptor interactions, information about the role of recombinant viruses in disease induction, and novel viral and cellular oncogenes implicated in pathogenesis, among other findings. The studies have contributed to an understanding of the selective forces that lead to predominance of distinctive FeLV isolates and disease outcomes in a natural population.

  6. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  7. Left Ventricle: Fully Automated Segmentation Based on Spatiotemporal Continuity and Myocardium Information in Cine Cardiac Magnetic Resonance Imaging (LV-FAST

    Directory of Open Access Journals (Sweden)

    Lijia Wang

    2015-01-01

    Full Text Available CMR quantification of LV chamber volumes typically and manually defines the basal-most LV, which adds processing time and user-dependence. This study developed an LV segmentation method that is fully automated based on the spatiotemporal continuity of the LV (LV-FAST. An iteratively decreasing threshold region growing approach was used first from the midventricle to the apex, until the LV area and shape discontinued, and then from midventricle to the base, until less than 50% of the myocardium circumference was observable. Region growth was constrained by LV spatiotemporal continuity to improve robustness of apical and basal segmentations. The LV-FAST method was compared with manual tracing on cardiac cine MRI data of 45 consecutive patients. Of the 45 patients, LV-FAST and manual selection identified the same apical slices at both ED and ES and the same basal slices at both ED and ES in 38, 38, 38, and 41 cases, respectively, and their measurements agreed within -1.6±8.7 mL, -1.4±7.8 mL, and 1.0±5.8% for EDV, ESV, and EF, respectively. LV-FAST allowed LV volume-time course quantitatively measured within 3 seconds on a standard desktop computer, which is fast and accurate for processing the cine volumetric cardiac MRI data, and enables LV filling course quantification over the cardiac cycle.

  8. Partial LVAD restores ventricular outputs and normalizes LV but not RV stress distributions in the acutely failing heart in silico

    OpenAIRE

    Sack, Kevin L.; Baillargeon, Brian; Acevedo-Bolton, Gabriel; Genet, Martin; Rebelo, Nuno; Kuhl, Ellen; Klein, Liviu; Weiselthaler, Georg M.; Burkhoff, Daniel; Franz, Thomas; Guccione, Julius M.

    2016-01-01

    Purpose: Heart failure is a worldwide epidemic that is unlikely to change as the population ages and life expectancy increases. We sought to detail significant recent improvements to the Dassault Systèmes Living Heart Model (LHM) and use the LHM to compute left ventricular (LV) and right ventricular (RV) myofiber stress distributions under the following 4 conditions: (1) normal cardiac function; (2) acute left heart failure (ALHF); (3) ALHF treated using an LV assist device (LVAD) flow rate o...

  9. Estimation of Maximum Allowable PV Connection to LV Residential Power Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    Maximum photovoltaic (PV) hosting capacity of low voltage (LV) power networks is mainly restricted by either thermal limits of network components or grid voltage quality resulted from high penetration of distributed PV systems. This maximum hosting capacity may be lower than the available solar...... potential of geographic area due to power network limitations even though all rooftops are fully occupied with PV modules. Therefore, it becomes more of an issue to know what exactly limits higher PV penetration level and which solutions should be engaged efficiently such as over sizing distribution...

  10. The B → D*lv form factor at zero recoil

    International Nuclear Information System (INIS)

    Simone, J.N.; Hashimoto, S.; El-Khadra, A.X.; Kronfeld, A.S.; Mackenzie, P.B.; Ryan, S.M.

    2000-01-01

    We describe a model independent lattice QCD method for determining the deviation from unity for h A1 (1), the B → D*lv form factor at zero recoil. We extend the double ratio method previously used to determine the B → Dlv form factor. The bulk of statistical and systematic errors cancel in the double ratios we consider, yielding form factors which promise to reduce present theoretical uncertainties in the determination of parallel V cb parallel. We present results from a prototype calculation at a single lattice spacing corresponding to β = 5.7

  11. Voltage regulation in LV grids by coordinated volt-var control strategies

    DEFF Research Database (Denmark)

    Juamperez Goñi, Miguel Angel; Yang, Guangya; Kjær, Søren Bækhøj

    2014-01-01

    in a representative LV network in Bornholm Island using a multi-objective genetic algorithm. The approach is to increase the reactive power contribution of the inverters closest to the transformer during overvoltage conditions. Two standard reactive power control concepts, cosΦ(P) and Q(U), are simulated and compared...... in terms of network power losses and voltage level along the feeder. As a practical implementation, a reconfigurable hardware is used for developing a testing platform based on real-time measurements to regulate the reactive power level. The proposed testing platform has been developed within PVNET...

  12. Percutaneous removal of a pacing electrode

    International Nuclear Information System (INIS)

    Hoehne, U.; Schild, H.; Hake, U.

    1989-01-01

    The large number of pace-makers introduced transvenously has resulted in increasing the number of complications, amongst which infections and dislocations are prominent. It is usually necessary to remove the electrode, which can be attempted percutaneously by using a Dormia basket, a loop or forceps. Amongst the complications of this procedure are tears to the myocardium, with the risk of pericardial tamponade, or tears of the tricuspid valve leading to tricuspid insufficiency. Consequently, thoracic surgical intervention should be available if necessary. Four successful procedures are described. (orig.) [de

  13. Pacing the US magnetic fusion program

    International Nuclear Information System (INIS)

    1989-01-01

    This study addresses the priority and pace of the nation's magnetic fusion research and development program in the context of long-term national energy policy. In particular, the committee interpreted its task as follows: To review the implications of long-term national energy policy for current research and development in magnetic fusion; to identify factors that should enter the further development of such policy to reduce risks associated with the future electricity supply system; to propose criteria applicable to research and develop in electric generation in reaching long-term energy policy goals; to apply these criteria to magnetic fusion and alternative electric generation technologies in order to develop recommendations on the priority pace of the magnetic fusion program; and to present its results in a final report. The most important goals of the US Department of Energy's current Magnetic Fusion Energy Program Plan are to demonstrate the scientific and engineering feasibility of fusion, Demonstrating engineering feasibility will require the design, construction, and operation of an engineering test reactor, which the plan envisions financing through a combination of domestic and international funding. The committee believes that current domestic program funding levels are inadequate to meet even the near-term objectives of the plan

  14. Surface glycosaminoglycans mediate adherence between HeLa cells and Lactobacillus salivarius Lv72.

    Science.gov (United States)

    Martín, Rebeca; Martín, Carla; Escobedo, Susana; Suárez, Juan E; Quirós, Luis M

    2013-09-17

    The adhesion of lactobacilli to the vaginal surface is of paramount importance to develop their probiotic functions. For this reason, the role of HeLa cell surface proteoglycans in the attachment of Lactobacillus salivarius Lv72, a mutualistic strain of vaginal origin, was investigated. Incubation of cultures with a variety of glycosaminoglycans (chondroitin sulfate A and C, heparin and heparan sulfate) resulted in marked binding interference. However, no single glycosaminoglycan was able to completely abolish cell binding, the sum of all having an additive effect that suggests cooperation between them and recognition of specific adhesins on the bacterial surface. In contrast, chondroitin sulfate B enhanced cell to cell attachment, showing the relevance of the stereochemistry of the uronic acid and the sulfation pattern on binding. Elimination of the HeLa surface glycosaminoglycans with lyases also resulted in severe adherence impairment. Advantage was taken of the Lactobacillus-glycosaminoglycans interaction to identify an adhesin from the bacterial surface. This protein, identify as a soluble binding protein of an ABC transporter system (OppA) by MALDI-TOF/(MS), was overproduced in Escherichia coli, purified and shown to interfere with L. salivarius Lv72 adhesion to HeLa cells. These data suggest that glycosaminoglycans play a fundamental role in attachment of mutualistic bacteria to the epithelium that lines the cavities where the normal microbiota thrives, OppA being a bacterial adhesin involved in the process.

  15. Biocorrosion of 316LV steel used in oral cavity due to Desulfotomaculum nigrificans bacteria.

    Science.gov (United States)

    Mystkowska, Joanna; Ferreira, Jose A; Leszczyńska, Katarzyna; Chmielewska, Sylwia; Dąbrowski, Jan Ryszard; Wieciński, Piotr; Kurzydłowski, Krzysztof Jan

    2017-01-01

    Corrosion processes of metallic biomaterials in the oral cavity pose a significant limitation to the life and reliable functioning of dental materials. In this article, the influence of environment bacteria Desulfotomaculum nigrificans sulfate reducing bacteria on the corrosion processes of 316LV steel was assessed. After 14 and 28 days of contact of the material with the bacterial environment, the surfaces of the tested biomaterial were observed by means of confocal scanning laser microscopy, and their chemical composition was studied using X-Ray Photoelectron Spectrometry and a scanning transmission electron microscopy. Corrosive changes, the presence of sulfur (with atomic concentration of 0.5%) on the surface of the biomaterial and the presence of a thin oxide layer (thickness of ∼20 nm) under the surface of the steel were observed. This corrosion layer with significant size reduction of grains was characterized by an increased amount of oxygen (18% mas., p < 0.001) in comparison to untreated 316LV steel (where oxygen concentration - 10% mas.). Image analysis conducted using APHELION software indicated that corrosion pits took up ∼2.8% of the total tested surface. The greatest number of corrosion pits had a surface area within the range of 100-200 μm 2 . © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 222-229, 2017. © 2015 Wiley Periodicals, Inc.

  16. Interatrial septum pacing decreases atrial dyssynchrony on strain rate imaging compared with right atrial appendage pacing.

    Science.gov (United States)

    Yasuoka, Yoshinori; Abe, Haruhiko; Umekawa, Seiko; Katsuki, Keiko; Tanaka, Norio; Araki, Ryo; Imanaka, Takahiro; Matsutera, Ryo; Morisawa, Daisuke; Kitada, Hirokazu; Hattori, Susumu; Noda, Yoshiki; Adachi, Hidenori; Sasaki, Tatsuya; Miyatake, Kunio

    2011-03-01

    Interatrial septum pacing (IAS-P) decreases atrial conduction delay compared with right atrial appendage pacing (RAA-P). We evaluate the atrial contraction with strain rate of tissue Doppler imaging (TDI) during sinus activation or with IAS-P or RAA-P. Fifty-two patients with permanent pacemaker for sinus node disease were enrolled in the study. Twenty-three subjects were with IAS-P and 29 with RAA-P. The time from end-diastole to peak end-diastolic strain rate was measured and corrected with RR interval on electrocardiogram. It was defined as the time from end-diastole to peak end-diastolic strain rate (TSRc), and the balance between maximum and minimum TSRc at three sites (ΔTSRc) was compared during sinus activation and with pacing rhythm in each group. There were no significant differences observed in general characteristics and standard echocardiographic parameters except the duration of pacing P wave between the two groups. The duration was significantly shorter in the IAS-P group compared with the RAA-P group (95 ± 34 vs 138 ± 41; P = 0.001). TSRc was significantly different between sinus activation and pacing rhythm (36.3 ± 35.7 vs 61.6 ± 36.3; P = 0.003) in the RAA-P group, whereas no significant differences were observed in the IAS-P group (25.4 ± 12.1 vs 27.7 ± 14.7; NS). During the follow-up (mean 2.4 ± 0.7 years), the incidence of paroxysmal atrial fibrillation (AF) conversion to permanent AF was not significantly different between the two groups. IAS-P decreased the contraction delay on atrial TDI compared to RAA-P; however, it did not contribute to the reduction of AF incidence in the present study. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  17. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  18. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  19. Benazepril inhibited the NF-κB and TGF-β networking on LV hypertrophy in rats.

    Science.gov (United States)

    Yan, Shi-Hai; Zhao, Ning-Wei; Zhu, Xuan-Xuan; Wang, Qiong; Wang, Hai-Dan; Fu, Rui; Sun, Yuan; Li, Qi-Yi

    2013-05-01

    Benazepril, an angiotensin-converting enzyme (ACE) inhibitor, has been used to treat hypertension, congestive heart failure, and chronic renal failure. However, its biological activity and mechanism of action in inflammation are not fully identified. The present study was designed to determine the in vivo anti-inflammatory effects of benazepril on LV hypertrophy in rats. LV hypertrophy was produced in rats by abdominal aortic coarctation. They were then divided into the following groups: sham operation; LV hypertrophy; LV hypertrophy+benazepril (1mg/kg in a gavage, once a day for 4 weeks). Both morphological assays (hemodynamic and hemorheological measurement; LV hypertrophy assessment), and molecular assays (protein levels of Collagen type I/III, TNF-α and VCAM-1; TGF-β gene expression; NF-κB or Smad activation; intracellular ROS production) were performed. The following effects were observed in rats treated with benazepril: (1) marked improvements in hemodynamic and hemorheological parameters; (2) significant reductions in LV hypertrophy, dilatation and fibrosis; (3) significantly attenuated protein levels of Collagen type I/III, TGF-β, TNF-α and VCAM-1, NF-κB or Smad activation, as well as intracellular ROS production. These results suggest that the anti-inflammatory properties of benazepril may be ascribed to their down-regulation of both NF-κB and TGF-β signaling pathways by acting on the intracellular ROS production in rats with LV hypertrophy, thus supporting the use of benazepril as an anti-inflammatory agent. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. The effects of anodal-tDCS on corticospinal excitability enhancement and its after-effects: conventional versus unihemispheric concurrent dual-site stimulation

    Directory of Open Access Journals (Sweden)

    Bita eVaseghi

    2015-09-01

    Full Text Available Previous researchers have approved the ability of anodal transcranial direct current stimulation (a-tDCS of the primary motor cortex (M1 to enhance corticospinal excitability (CSE. The primary aim of the current study was to investigate the effect of concurrent stimulation of M1 and a functionally connected cortical site of M1 on CSE modulation. This new technique is called unihemispheric concurrent dual-site a-tDCS (a-tDCSUHCDS. The secondary aim was to investigate the mechanisms underlying the efficacy of this new approach in healthy individuals. In a randomized crossover study, 12 healthy right-handed volunteers received a-tDCS under five conditions: a-tDCS of M1, a-tDCSUHCDS of M1– dorsolateral prefrontal cortex (DLPFC, a-tDCSUHCDS of M1– primary sensory cortex (S1, a-tDCSUHCDS of M1– primary visual cortex (V1, and sham a-tDCSUHCDS. Peak-to-peak amplitude of transcranial magnetic stimulation (TMS induced MEPs, short-interval intracortical inhibition and intracortical facilitation were assessed before and four times after each condition. A-tDCSUHCDS conditions induced larger MEPs than conventional a-tDCS. The level of M1 CSE was significantly higher following a-tDCSUHCDS of M1-DLPFC than other a-tDCSUHCDS conditions (P < 0.001, and lasted for over 24 hours. The paired-pulse TMS results after a-tDCS of M1-DLPFC showed significant facilitatory increase and inhibitory change. A-tDCSUHCDS of M1-DLPFC increases M1 CSE twofold that of conventional a-tDCS. A-tDCSUHCDS of M1-DLPFC enhances the activity of glutamergic mechanisms for at least 24 hours. Such long-lasting M1 CSE enhancement induced by a-tDCSUHCDS of M1-DLPFC could be a valuable finding in clinical scenarios such as learning, motor performance, or pain management.The present study has been registered on the Australian New Zealand Clinical Trial at http://www.anzctr.org.au/ with registry number of ACTRN12614000817640.

  1. Hibernia field construction pace picks up speed

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that the pace of construction is increasing for the $5.2 billion (Canadian) Hibernia oil field development project off Newfoundland with a new partner close to signing on. Texaco, Inc. is reported ready to pick up a 25% interest in the project within a month. Construction activity for offshore systems was cut 50% last February when Gulf Canada Resources Inc. The it planned to withdraw from its 25% interest in Hibernia. Since then, remaining interest owners Mobil Oil Canada Ltd., Chevron Canada Resources Ltd., and Petro-Canada have been seeking new partners. The effort has focused on Texaco with Canadian Energy Minister Jake Epp playing a role in talks. Hibernia's construction work force has risen to 850 from a low of 600. A spokesman for Hibernia Management and Development Co., project manager, the a steady increase in the work force is planned

  2. Phrenic pacing compared with mechanical ventilation

    DEFF Research Database (Denmark)

    Andersen, Morten Packert; Laub, Michael; Biering-Sørensen, Fin

    2017-01-01

    mechanical ventilator dependent tetraplegics met the inclusion criteria. Data were retrieved from medical records and a structured follow-up interview with seven individuals from each group. RESULTS: No significant differences were found when comparing age at injury, time since injury, length...... of hospitalization, incidence of pneumonia, number of pneumonia hospitalizations, number of tracheal suctions, speech quality and activities of daily living or quality of life. On the Short Form Health Survey (SF36) mental health summary the median for both users of phrenic nerve pacing and users of mechanical...... ventilation was one s.d. above the mean of a standard population. CONCLUSIONS: Nine people have had a phrenic nerve pacer implanted. They do not significantly differ from a group of home mechanical ventilator dependent tetraplegics on a number of performance measures, but both groups seem to have better...

  3. IAEA instrumentation programme keeping pace with technology

    International Nuclear Information System (INIS)

    Fortakov, V.; Rundquist, D.E.

    1995-01-01

    Nuclear components, nuclear practices and nuclear facilities have all improved with the maturing of the industry. These improvements have been driven by forces, which are beyond the normal evolutionary pressures, such as increased safety, as low as possible radiation exposure for the workers as well as for the public and the increasing competiveness of alternative forms of energy generation. International nuclear safeguards has had to keep pace with these technological and administrative changes. Moreover, the political climate has changed since the initial implementation of safeguards under the Non-Proliferation Treaty. Implementation of safeguards agreements has accommodated to these changes as well as to the technical innovations. One important component of safeguards implementation, namely the instruments deployed by inspectors, has matured with the help of Member States. Continued efforts in the development and deployment of appropriate instruments are needed to maintain an acceptable level of efficiency and credibility. (orig.)

  4. Current status of the Citrus leprosis virus (CiLV -C and its vector Brevipalpus phoenicis (Geijskes

    Directory of Open Access Journals (Sweden)

    Guillermo León M

    2012-08-01

    Full Text Available The Citrus leprosis virus CiLV-C is a quarantine disease of economic importance. Over the past 15 years, this disease has spread to several countries of Central and South America. Colombia has about 45,000 hectares of citrus planted with an annual production of 750,000 tonnes. The CiLV-C has only been detected in the departments of Meta, Casanare and recently Tolima. Meta has 4,300 hectares representing 10% of the national cultivated area, and Casanare, where CiLV-C appeared in 2004, has no more than 500 ha planted with citrus. The presence of the Citrus leprosis virus in Colombia could affect the international market for citrus, other crops and ornamental plants with the United States and other countries without the disease. The false spider mite Brevipalpus phoenicis (Geijskes (Acari: Tenuipalpidae is the main vector of the CiLV-C. Disease management is based on control programs of the vector and diminishing host plants. Chemical mite control is expensive, wasteful and generates resistance to different acaricides. This paper provides basic information on CiLV-C and its vector, advances in diagnosis and methods to control the disease and prevention of its spread

  5. BezRindas.lv biļešu tirdzniecības Android lietotne

    OpenAIRE

    Upītis, Reinis

    2014-01-01

    Kvalifikācijas darbā tiek aprakstīta autobusu biļešu tirdzniecības lietotne, kas ir paredzēta viedtālruņiem ar Android operētājsistēmu. Mobilā lietotne paredzēta kā papildinājums jau esošam servisam – Bezrindas.lv. Aprakstītās sistēmas izveide atvieglotu biļešu iegādi lietotājiem, kas to vēlētos darīt ar saviem viedtālruņiem.

  6. Efficient Control of Active Transformers for Increasing the PV Hosting Capacity of LV Grids

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Degner, Thomas

    2016-01-01

    . The potential interferences between the operation of active transformers and the reactive power absorption by PV inverters are investigated, and a voltage droop control approach is proposed for the efficient control of these transformers during high PV generation periods. The proposed method can potentially...... increase the PV hosting capacity of the grid, while eliminating the need for a complex and centralized controller. The voltages of specific locations or the grid state estimations provide adequate data for adjustments of the droop parameters. The simulations and field test results associated...... with the implementation of the proposed method to a newly developed active LV grid with high PV penetration in Felsberg, Germany, confirm the efficiency of the proposed method....

  7. Evolution of the Nova Vulpeculae no.1 1968 (LV Vul) spectrum after the maximum brightness

    International Nuclear Information System (INIS)

    Andrijya, I.; Antipova, L.I.; Babaev, M.B.; AN Azerbajdzhanskoj SSR, Baku. Shemakhinskaya Astrofizicheskaya Observatoriya)

    1986-01-01

    The analysis of the spectral evolution of LV Vulpeculae 1968 after the maximum brightness was carried out. It is shown that the pre-maximum spectrum was replaced by the principal one in less than 24sup(h). The diffuse enhanced scectrum and the Orion one existed already when the Nova brightness has decreased only by 0.4sup(m) and 0.5sup(m) respectively. The radial velocities of the Orion spectrum coincided with those of the diffuse enhanced one during the total observational period. The Orion spectrum consists of the lines of He I, N2, O 2 and may be H 1. The appearance of two additional components is probably due to splitting of the principal and diffuse enhanced spectrum

  8. Impact of Distributed Generation Grid Code Requirements on Islanding Detection in LV Networks

    Directory of Open Access Journals (Sweden)

    Fabio Bignucolo

    2017-01-01

    Full Text Available The recent growing diffusion of dispersed generation in low voltage (LV distribution networks is entailing new rules to make local generators participate in network stability. Consequently, national and international grid codes, which define the connection rules for stability and safety of electrical power systems, have been updated requiring distributed generators and electrical storage systems to supply stabilizing contributions. In this scenario, specific attention to the uncontrolled islanding issue has to be addressed since currently required anti-islanding protection systems, based on relays locally measuring voltage and frequency, could no longer be suitable. In this paper, the effects on the interface protection performance of different LV generators’ stabilizing functions are analysed. The study takes into account existing requirements, such as the generators’ active power regulation (according to the measured frequency and reactive power regulation (depending on the local measured voltage. In addition, the paper focuses on other stabilizing features under discussion, derived from the medium voltage (MV distribution network grid codes or proposed in the literature, such as fast voltage support (FVS and inertia emulation. Stabilizing functions have been reproduced in the DIgSILENT PowerFactory 2016 software environment, making use of its native programming language. Later, they are tested both alone and together, aiming to obtain a comprehensive analysis on their impact on the anti-islanding protection effectiveness. Through dynamic simulations in several network scenarios the paper demonstrates the detrimental impact that such stabilizing regulations may have on loss-of-main protection effectiveness, leading to an increased risk of unintentional islanding.

  9. PACE3 - front-end chip for the CMS Preshower

    CERN Multimedia

    Aspel, Paul

    2003-01-01

    This is PACE3 which is the front-end chip for the CMS Preshower. In fact PACE3 is the combination of two ASICs called Delta3 and PACEAM3. Delta3 is on the left and PACEAM3 is on the right. The two ASICs are bonded together and then packaged within a single 196 pin fpBGA package.

  10. Social Interaction in Self-Paced Distance Education

    Science.gov (United States)

    Anderson, Terry; Upton, Lorne; Dron, Jon; Malone, Judi; Poelhuber, Bruno

    2015-01-01

    In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions…

  11. Development of tools to manage the operational monitoring and pre-design of the NPP-LV cycle

    International Nuclear Information System (INIS)

    Perusquia, R.; Arredondo S, C.; Hernandez M, J. L.; Montes T, J. L.; Castillo M, A.; Ortiz S, J. J.

    2015-09-01

    This paper presents the development of tools to facilitate the management so much, the operational monitoring of boiling water reactors (BWR) of the nuclear power plant of Laguna Verde (NPP-LV) through independent codes, and how to carry out the static calculations corresponding to process of optimized pre-design of the reference cycle next to current cycle. The progress and preliminary results obtained with the program SACal, developed at Instituto Nacional de Investigaciones Nucleares (ININ), central tool to achieve provide a management platform of the operational monitoring and pre-design of NPP-LV cycle are also described. The reached preliminary advances directed to get an Analysis center and automated design of fuel assembly cells are also presented, which together with centers or similar modules related with the fuel reloads form the key part to meet the targets set for the realization of a Management Platform of Nuclear Fuel of the NPP-LV. (Author)

  12. Adverse effects of permanent atrial fibrillation on heart failure in patients with preserved left ventricular function and chronic right apical pacing for complete heart block.

    Science.gov (United States)

    Lampe, Brigitte; Hammerstingl, Christoph; Schwab, Jörg Otto; Mellert, Fritz; Stoffel-Wagner, Birgit; Grigull, Andreas; Fimmers, Rolf; Maisch, Bernhard; Nickenig, Georg; Lewalter, Thorsten; Yang, Alexander

    2012-10-01

    The impact of atrial fibrillation (AF) on heart failure (HF) was evaluated in patients with preserved left ventricular (LV) function and long-term right ventricular (RV) pacing for complete heart block. Clinical, echocardiographic, and laboratory parameters of HF were assessed in 35 patients with established AF who had undergone ablation of the atrioventricular node and pacemaker implantation (Group A) and 31 patients who received dual-chamber pacing for spontaneous complete heart block (Group B). During a follow-up period of 12.7 ± 7.5 years, New York Heart Association (NYHA) functional class increased from 1.3 ± 0.5 to 2.1 ± 0.6 (p Left ventricular ejection fraction (LVEF) decreased from 59.7 ± 5.1 to 53.0 ± 8.2 (p function were moderately depressed in Group A compared with those in Group B: NYHA class 2.1 ± 0.6 versus 1.6 ± 0.7, p = 0.001; LVEF 53.0 ± 8.2 versus 56.9 ± 7.0 %, p brain natriuretic peptide (NT-proBNP) 1116.8 ± 883.9 versus 622.9 ± 1059.4 pg/ml, p 10 %, increasing NYHA class ≥1, and NT-proBNP levels >1,000 pg/ml. Permanent AF was associated with adverse effects on LV function and symptoms of HF in patients with long-term RV pacing for complete heart block, and appears to play an important role in the development of HF in this specific patient cohort.

  13. Relationship between echocardiographic LV mass and ECG based left ventricular voltages in an adolescent population: related or random?

    Science.gov (United States)

    Czosek, Richard J; Cnota, James F; Knilans, Timothy K; Pratt, Jesse; Guerrier, Karine; Anderson, Jeffrey B

    2014-09-01

    In attempts to detect diseases that may place adolescents at risk for sudden death, some have advocated for population-based screening. Controversy exists over electrocardiography (ECG) screening due to the lack of specificity, cost, and detrimental effects of false positive or extraneous outcomes. Analyze the relationship between precordial lead voltage on ECG and left ventricle (LV) mass by echocardiogram in adolescent athletes. Retrospective cohort analysis of a prospectively obtained population of self-identified adolescent athletes during sports screening with ECG and echocardiogram. Correlation between ECG LV voltages (R wave in V6 [RV6] and S wave in lead V1 [SV1]) was compared to echocardiogram-based measurements of left ventricular mass. Potential effects on ECG voltages by body anthropometrics, including weight, body mass index (BMI), and body surface area were analyzed, and ECG voltages indexed to BMI were compared to LV mass indices to analyze for improved correlation. A total of 659 adolescents enrolled in this study (64% male). The mean age was 15.4 years (14-18). The correlations between LV mass and RV6, SV1, and RV6 + SV1 were all less than 0.20. The false positive rate for abnormal voltages was relatively high (5.5%) but improved if abnormal voltages in both RV6 and SV1 were mandated simultaneously (0%). Indexing ECG voltages to BMI significantly improved correlation to LV mass, though false positive findings were increased (12.9%). There is poor correlation between ECG precordial voltages and echocardiographic LV mass. This relationship is modified by BMI. This finding may contribute to the poor ECG screening characteristics. ©2014 Wiley Periodicals, Inc.

  14. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Nielsen, Jens Cosedis; Thomsen, Poul Erik B; Højberg, Søren

    2011-01-01

    In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any ...

  15. An Undergraduate Intern Program at PACES

    Science.gov (United States)

    Starks, Scott A.

    1997-01-01

    The University of Texas at El Paso (UTEP) established the Pan American Center for Earth and Environmental Studies (PACES) in 1995 to conduct basic and applied research that contributes to NASA's Mission to Planet Earth. Specifically, PACES provides a repository of remote sensing and other information that supports investigations into an improved understanding of geological, ecological and environmental processes occurring in the southwestern United States and Northern Mexico. Approximately 85% of UTEP's students come from El Paso County, a fast growing urban region representative of many large cities in the Southwest that have, or will soon have, a majority of their population composed of groups currently underrepresented in the scientific and technical workforce. UTEP's student population has an ethnic distribution (63% Hispanic, 32% Anglo, 3% African American, 1.5 % Asian American, and less than 1% Native American) that closely matches the demographics of the region it serves. Thus, UTEP has a mission to serve a multicultural population where minority students comprise the majority. Most Hispanic students at UTEP are primarily of Mexican origin. A large number are first or second-generation U.S. citizens. Characteristics that unite Hispanic students, in particular those of Mexican-origin, are a strong sense of family loyalty and a belief that all family members are responsible for contributing to the economic stability and well-being of the family. Most of their families are larger in number than the national average, and a variety of generations live together or share considerable resources. Thus, many young people feel an obligation and a desire to go to work at a young age and to continue working while in college, thereby assisting their parents and other family members. Older siblings understand that they have responsibilities to do household chores, to aid their younger siblings economically, and to assist elderly family members. This "work ethic" within the

  16. A prospective, randomized, double-blind, placebo-controlled parallel-group dual site trial to evaluate the effects of a Bacillus coagulans-based product on functional intestinal gas symptoms

    OpenAIRE

    Feldman Samantha; Alvarez Patricia; Schwartz Howard I; Kalman Douglas S; Pezzullo John C; Krieger Diane R

    2009-01-01

    Abstract Background This randomized double blind placebo controlled dual site clinical trial compared a probiotic dietary supplement to placebo regarding effects on gastrointestinal symptoms in adults with post-prandial intestinal gas-related symptoms (abdominal pain, distention, flatulence) but no gastrointestinal (GI) diagnoses to explain the symptoms. Methods Sixty-one adults were enrolled (age 36.5 ± 12.6 years; height 165.1 ± 9.2 cm; weight 75.4 ± 17.3 kg) and randomized to either Digest...

  17. Pushing the pace of tree species migration.

    Directory of Open Access Journals (Sweden)

    Eli D Lazarus

    Full Text Available Plants and animals have responded to past climate changes by migrating with habitable environments, sometimes shifting the boundaries of their geographic ranges by tens of kilometers per year or more. Species migrating in response to present climate conditions, however, must contend with landscapes fragmented by anthropogenic disturbance. We consider this problem in the context of wind-dispersed tree species. Mechanisms of long-distance seed dispersal make these species capable of rapid migration rates. Models of species-front migration suggest that even tree species with the capacity for long-distance dispersal will be unable to keep pace with future spatial changes in temperature gradients, exclusive of habitat fragmentation effects. Here we present a numerical model that captures the salient dynamics of migration by long-distance dispersal for a generic tree species. We then use the model to explore the possible effects of assisted colonization within a fragmented landscape under a simulated tree-planting scheme. Our results suggest that an assisted-colonization program could accelerate species-front migration rates enough to match the speed of climate change, but such a program would involve an environmental-sustainability intervention at a massive scale.

  18. Peritrophin-like protein from Litopenaeus vannamei (LvPT) involved in white spot syndrome virus (WSSV) infection in digestive tract challenged with reverse gavage

    Science.gov (United States)

    Xie, Shijun; Li, Fuhua; Zhang, Xiaojun; Zhang, Jiquan; Xiang, Jianhai

    2017-11-01

    The peritrophic membrane plays an important role in the defense system of the arthropod gut. The digestive tract is considered one of the major tissues targeted by white spot syndrome virus (WSSV) in shrimp. In this study, the nucleotide sequence encoding peritrophin-like protein of Litopenaeus vannamei (LvPT) was amplified from a yeast two-hybrid library of L. vannamei. The epitope peptide of LvPT was predicted with the GenScript OptimumAntigen™ design tool. An anti-LvPT polyclonal antibody was produced and shown to specifically bind a band at 27 kDa, identified as LvPT. The LvPT protein was expressed and its concentration determined. LvPT dsRNA (4 μg per shrimp) was used to inhibit LvPT expression in shrimp, and a WSSV challenge experiment was then performed with reverse gavage. The pleopods, stomachs, and guts were collected from the shrimp at 0, 24, 48, and 72 h post-infection (hpi). Viral load quantification showed that the levels of WSSV were significantly lower in the pleopods, stomachs, and guts of shrimp after LvPT dsRNA interference than in those of the controls at 48 and 72 hpi. Our results imply that LvPT plays an important role during WSSV infection of the digestive tract.

  19. Seroprevalence of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) in shelter cats on the island of Newfoundland, Canada.

    Science.gov (United States)

    Munro, Hannah J; Berghuis, Lesley; Lang, Andrew S; Rogers, Laura; Whitney, Hugh

    2014-04-01

    Feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) are retroviruses found within domestic and wild cat populations. These viruses cause severe illnesses that eventually lead to death. Housing cats communally for long periods of time makes shelters at high risk for virus transmission among cats. We tested 548 cats from 5 different sites across the island of Newfoundland for FIV and FeLV. The overall seroprevalence was 2.2% and 6.2% for FIV and FeLV, respectively. Two sites had significantly higher seroprevalence of FeLV infection than the other 3 sites. Analysis of sequences from the FeLV env gene (envelope gene) from 6 positive cats showed that 4 fell within the FeLV subtype-A, while 2 sequences were most closely related to FeLV subtype-B and endogenous feline leukemia virus (en FeLV). Varying seroprevalence and the variation in sequences at different sites demonstrate that some shelters are at greater risk of FeLV infections and recombination can occur at sites of high seroprevalence.

  20. The pace of aging: Intrinsic time scales in demography

    Directory of Open Access Journals (Sweden)

    Tomasz Wrycza

    2014-05-01

    Full Text Available Background: The pace of aging is a concept that captures the time-related aspect of aging. It formalizesthe idea of a characteristic life span or intrinsic population time scale. In the rapidly developing field of comparative biodemography, measures that account for inter-speciesdifferences in life span are needed to compare how species age. Objective: We aim to provide a mathematical foundation for the concept of pace. We derive desiredmathematical properties of pace measures and suggest candidates which satisfy these properties. Subsequently, we introduce the concept of pace-standardization, which reveals differences in demographic quantities that are not due to pace. Examples and consequences are discussed. Conclusions: Mean life span (i.e., life expectancy from birth or from maturity is intuitively appealing,theoretically justified, and the most appropriate measure of pace. Pace-standardizationprovides a serviceable method for comparative aging studies to explore differences indemographic patterns of aging across species, and it may considerably alter conclusionsabout the strength of aging.

  1. The surface glycoprotein of a natural feline leukemia virus subgroup A variant, FeLV-945, as a determinant of disease outcome.

    Science.gov (United States)

    Bolin, Lisa L; Ahmad, Shamim; Levy, Laura S

    2011-10-15

    Feline leukemia virus (FeLV) is a natural retrovirus of domestic cats associated with degenerative, proliferative and malignant diseases. Studies of FeLV infection in a cohort of naturally infected cats were undertaken to examine FeLV variation, the selective pressures operative in FeLV infection that lead to predominance of natural variants, and the consequences for infection and disease progression. A unique variant, designated FeLV-945, was identified as the predominant isolate in the cohort and was associated with non-T-cell diseases including multicentric lymphoma. FeLV-945 was assigned to the FeLV-A subgroup based on sequence analysis and receptor utilization, but was shown to differ in sequence from a prototype member of FeLV-A, designated FeLV-A/61E, in the long terminal repeat (LTR) and the surface glycoprotein gene (SU). A unique sequence motif in the FeLV-945 LTR was shown to function as a transcriptional enhancer and to confer a replicative advantage. The FeLV-945 SU protein was observed to differ in sequence as compared to FeLV-A/61E within functional domains known to determine receptor selection and binding. Experimental infection of newborn cats was performed using wild type FeLV-A/61E or recombinant FeLV-A/61E in which the LTR (61E/945L) or LTR and SU (61E/945SL) were exchanged for that of FeLV-945. Infection with either FeLV-A/61E or 61E/945L resulted in T-cell lymphoma of the thymus, although 61E/945L caused disease significantly more rapidly. In contrast, infection with 61E/945SL resulted in the rapid induction of a multicentric lymphoma of B-cell origin, thus recapitulating the outcome of natural infection and implicating FeLV-945 SU as a determinant of disease outcome. Recombinant FeLV-B was detected infrequently and at low levels in multicentric lymphomas, and was thereby not implicated in disease induction. Preliminary studies of receptor interaction indicated that virus particles bearing FeLV-945 SU bind to the FeLV-A receptor more

  2. Modelling wetland-groundwater interactions in the boreal Kälväsvaara esker, Northern Finland

    Science.gov (United States)

    Jaros, Anna; Rossi, Pekka; Ronkanen, Anna-Kaisa; Kløve, Bjørn

    2016-04-01

    Many types of boreal peatland ecosystems such as alkaline fens, aapa mires and Fennoscandia spring fens rely on the presence of groundwater. In these ecosystems groundwater creates unique conditions for flora and fauna by providing water, nutrients and constant water temperature enriching local biodiversity. The groundwater-peatland interactions and their dynamics are not, however, in many cases fully understood and their measurement and quantification is difficult due to highly heterogeneous structure of peatlands and large spatial extend of these ecosystems. Understanding of these interactions and their changes due to anthropogenic impact on groundwater resources would benefit the protection of the groundwater dependent peatlands. The groundwater-peatland interactions were investigated using the fully-integrated physically-based groundwater-surface water code HydroGeoSphere in a case study of the Kälväsvaara esker aquifer, Northern Finland. The Kälväsvaara is a geologically complex esker and it is surrounded by vast aapa mire system including alkaline and springs fens. In addition, numerous small springs occur in the discharge zone of the esker. In order to quantify groundwater-peatland interactions a simple steady-state model was built and results were evaluated using expected trends and field measurements. The employed model reproduced relatively well spatially distributed hydrological variables such as soil water content, water depths and groundwater-surface water exchange fluxes within the wetland and esker areas. The wetlands emerged in simulations as a result of geological and topographical conditions. They could be identified by high saturation levels at ground surface and by presence of shallow ponded water over some areas. The model outputs exhibited also strong surface water-groundwater interactions in some parts of the aapa system. These areas were noted to be regions of substantial diffusive groundwater discharge by the earlier studies. In

  3. Pacing: a concept analysis of the chronic pain intervention.

    Science.gov (United States)

    Jamieson-Lega, Kathryn; Berry, Robyn; Brown, Cary A

    2013-01-01

    The intervention of pacing is regularly recommended for chronic pain patients. However, pacing is poorly defined and appears to be interpreted in varying, potentially contradictory manners within the field of chronic pain. This conceptual lack of clarity has implications for effective service delivery and for researchers' ability to conduct rigorous study. An examination of the background literature demonstrates that while pacing is often one part of a multidisciplinary pain management program, outcome research is hindered by a lack of a clear and shared definition of this currently ill-defined construct. To conduct a formal concept analysis of the term 'pacing'. A standardized concept analysis process (including literature scoping to identify all uses of the concept, analysis to determine defining attributes of the concept and identification of model, borderline and contrary cases) was used to determine what the concept of pacing does and does not represent within the current evidence base. A conceptual model including the core attributes of action, time, balance, learning and self-management emerged. From these attributes, an evidence-based definition for pacing was composed and distributed to stakeholders for review. After consideration of stakeholder feedback, the emergent definition of pacing was finalized as follows: "Pacing is an active self-management strategy whereby individuals learn to balance time spent on activity and rest for the purpose of achieving increased function and participation in meaningful activities". The findings of the present concept analysis will help to standardize the use and definition of the term pacing across disciplines for the purposes of both pain management and research.

  4. Experimental infection of Tilapia Lake Virus (TiLV) in Nile tilapia (Oreochromis niloticus) and red tilapia (Oreochromis spp.).

    Science.gov (United States)

    Tattiyapong, Puntanat; Dachavichitlead, Worawan; Surachetpong, Win

    2017-08-01

    Since 2015, a novel orthomyxo-like virus, tilapia lake virus (TiLV) has been associated with outbreaks of disease and massive mortality of cultured Nile and red tilapia (Oreochromis niloticus and Oreochromis spp., respectively) in Thailand. In this study, TiLV was isolated from field samples and propagated in the permissive E-11 cell line, with cytopathic effect (CPE) development within 3-5days post-inoculation. Electron micrographs of infected E-11 cells and fish tissues confirmed the rounded, enveloped virions of 60 to 80nm with characteristics very similar to those of Orthomyxoviridae. In vivo challenge studies showed that high mortality in Nile (86%) and red tilapia (66%) occurred within 4-12days post-infection. The virus was re-isolated from challenged fish tissues in the permissive cell line, and PCR analysis confirmed TiLV as a causative pathogen. The distinct histopathology of challenged fish included massive degeneration and inflammatory cell infiltration in the liver and brain as well as the presence of eosinophilic intracytoplasmic inclusions in hepatocytes and splenic cells. Our results fulfilled Koch's postulates and confirmed that TiLV is an etiologic agent of mass mortality of tilapia in Thailand. The emergence of this virus in many countries has helped increase awareness that it is a potential threat to tilapia aquacultured in Thailand, Asia, and worldwide. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Impact of biogenic nanoscale metals Fe, Cu, Zn and Se on reproductive LV chickens

    International Nuclear Information System (INIS)

    Nguyen, Quy Khiem; Nguyen, Van Kien; Nguyen, Khac Thinh; Nguyen, Duy Dieu; Nguyen, Hoai Chau; Tran, Xuan Tin; Nguyen, Huu Cuong; Phung, Duc Tien

    2015-01-01

    Using biogenic nanoscale metals (Fe, Cu, ZnO, Se) to supplement into diet premix of reproductive LV (a Vietnamese Luong Phuong chicken breed) chickens resulted in certain improvement of poultry farming. The experimental data obtained showed that the farming indices depend mainly on the quantity of nanocrystalline metals which replaced the inorganic mineral component in the feed premix. All four experimental groups with different quantities of the replacement nano component grew and developed normally with livability reaching 91 to 94%, hen’s bodyweight at 38 weeks of age and egg weight ranged from 2.53–2.60 kg/hen and 50.86–51.55 g/egg, respectively. All these farming indices together with laying rate, egg productivity and chick hatchability peaked at group 5 with 25% of nanoscale metals compared to the standard inorganic mineral supplement, while feed consumption was lowest. The results also confirmed that nanocrystalline metals Fe, Cu, ZnO and Se supplemented to chicken feed were able to decrease inorganic minerals in the diet premixes at least four times, allowing animals to more effectively absorb feed minerals, consequently decreasing environmental pollution risks. (paper)

  6. Fast Paced, Low Cost Projects at MSFC

    Science.gov (United States)

    Watson-Morgan, Lisa; Clinton, Raymond

    2012-01-01

    What does an orbiting microsatellite, a robotic lander and a ruggedized camera and telescope have in common? They are all fast paced, low cost projects managed by Marshall Space Flight Center (MSFC) teamed with successful industry partners. MSFC has long been synonymous with human space flight large propulsion programs, engineering acumen and risk intolerance. However, there is a growing portfolio/product line within MSFC that focuses on these smaller, fast paced projects. While launching anything into space is expensive, using a managed risk posture, holding to schedule and keeping costs low by stopping at egood enough f were key elements to their success. Risk is defined as the possibility of loss or failure per Merriam Webster. The National Aeronautics and Space Administration (NASA) defines risk using procedural requirement 8705.4 and establishes eclasses f to discern the acceptable risk per a project. It states a Class D risk has a medium to significant risk of not achieving mission success. MSFC, along with industry partners, has created a niche in Class D efforts. How did the big, cautious MSFC succeed on these projects that embodied the antithesis of its heritage in human space flight? A key factor toward these successful projects was innovative industry partners such as Dynetics Corporation, University of Alabama in Huntsville (UAHuntsville), Johns Hopkins Applied Physics Laboratory (JHU APL), Teledyne Brown Engineering (TBE), Von Braun Center for Science and Innovation (VCSI), SAIC, and Jacobs. Fast Affordable Satellite Technology (FastSat HSV01) is a low earth orbit microsatellite that houses six instruments with the primary scientific objective of earth observation and technology demonstration. The team was comprised of Dynetics, UAHuntsvile, SAIC, Goddard Space Flight Center (GSFC) and VCSI with the United States Air Force Space Test Program as the customer. The team completed design, development, manufacturing, environmental test and integration in

  7. The Efficacy of Self-Paced Study in Multitrial Learning

    Science.gov (United States)

    de Jonge, Mario; Tabbers, Huib K.; Pecher, Diane; Jang, Yoonhee; Zeelenberg, René

    2015-01-01

    In 2 experiments we investigated the efficacy of self-paced study in multitrial learning. In Experiment 1, native speakers of English studied lists of Dutch-English word pairs under 1 of 4 imposed fixed presentation rate conditions (24 × 1 s, 12 × 2 s, 6 × 4 s, or 3 × 8 s) and a self-paced study condition. Total study time per list was equated for…

  8. Factors explaining voluntary participation in PACE-Vaquita

    OpenAIRE

    Sara Avila

    2011-01-01

    Vaquita marina, a small species of porpoise endemic to the Northern Gulf of California in Mexico, is the world’s most endangered cetacean species. With the purpose of preserving vaquita, the Mexican government launched PACE-Vaquita in 2008. This voluntary program offers an innovative schedule of compensations: as in a payment for conservation program, PACE-Vaquita compensates for temporary reductions in fishing reductions in fishing effort; as in a program to accelerate technology adoption,PA...

  9. Pacing in swimming - variability and effects of manipulations

    OpenAIRE

    Skorski, Sabrina

    2015-01-01

    Introduction: In any athletic event, the ability to appropriately distribute energy, is essential to prevent premature fatigue prior to the completion of the event. In sport science literature this is termed ‘pacing’. Within the past decade, research aiming to better understand the underlying mechanisms influencing the selection of an athlete’s pacing during exercise has dramatically increased. It is suggested that pacing is a combination of anticipation, knowledge of the end-point, prior exp...

  10. PACE and the Federal Housing Finance Agency (FHFA)

    Energy Technology Data Exchange (ETDEWEB)

    Zimring, Mark; Fuller, Merrian

    2010-03-17

    The FHFA regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On June 18, 2009, James B. Lockhart III, then Director of FHFA, released a letter expressing concern about the negative impact of energy loan tax assessment programs (ELTAPs) - also known as Property Assessed Clean Energy (PACE) programs - on both the housing finance system and homeowner program participants. Subsequently, a number of PACE proponents responded to the concerns laid out in the FHFA letter. In early Fall 2009, word circulated that FHFA was planning to follow its June letter with guidance to other agencies, possibly including Fannie Mae and Freddie Mac, discouraging them from buying loans on properties subject to PACE-type assessment liens. This triggered a second round of stakeholder letters, several of which were addressed to President Obama. On October 18, 2009, the White House, in what some believe was an attempt to obviate the need for FHFA guidance, released a Policy Framework for PACE Financing Programs that outlined best practices guidance for homeowner and lender protection. As of February 2010, FHFA and the GSEs have agreed to monitor PACE programs and work with stakeholders and the Administration to consider additional guidance beyond the Policy Framework and to collect more information on PACE program efficacy and risks. A summary of the communications timeline and highlights of the communications are provided.

  11. The proviral genome of radiation leukemia virus (RadLV): molecular cloning, restriction analysis and integration sites in tumor cell DNA

    International Nuclear Information System (INIS)

    Janowski, M.; Merregaert, J.; Nuyten, J.M.; Maisin, J.R.

    1984-01-01

    An infectious clone of the linear, unintegrated RadLV provirus was obtained by insertion in the plasmid pBR322. Its restriction map was indistinguishable from that of the majority of the multiple proviral copies, which are found apparently at random sites in the DNA of RadLV-induced rat thymic lymphomas [fr

  12. Correlation of trabeculae and papillary muscles with clinical and cardiac characteristics and impact on CMR measures of LV anatomy and function

    NARCIS (Netherlands)

    Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L T F; Salton, Carol J.; Blease, Susan J.; Yeon, Susan B.; Breeuwer, Marcel; O'Donnell, Christopher J.; Manning, Warren J.

    2012-01-01

    Objectives: The goal of this study was to assess the relationship of left ventricular (LV) trabeculae and papillary muscles (TPM) with clinical characteristics in a community-based, free-living adult cohort and to determine the effect of TPM on quantitative measures of LV volume, mass, and ejection

  13. Acumulación/eliminación de oxitetraciclina en el camarón blanco, lv y su residualidad en dietas artificiales

    OpenAIRE

    Montoya, Nelson; Reyes, Eduardo

    2002-01-01

    Acumulación/eliminación de oxitetraciclina en el camarón blanco, LV y su residualidad en dietas artificiales Acumulación/eliminación de oxitetraciclina en el camarón blanco, LV y su residualidad en dietas artificiales

  14. Quantitative gated SPECT- a comparative study of two algorithms for parameters of perfusion and LV function

    International Nuclear Information System (INIS)

    Ali, A.Z.

    2007-01-01

    Full text: Aim: To compare the perfusion and LV function parameters as quantified by 4D-MSPECT and ECT in the same patient group and a qualitative comparison of the reconstructed slices by two different experts. Materials and methods: Thirty-one consecutive patients underwent gated myocardial perfusion SPECT using a two-day protocol. The gated and ungated data were reconstructed by back projection method. Quantitative analysis was performed on the same set of reconstructed slices by 4D-MSPECT and Emory Cardiac Tool Box. The reconstructed slices were read qualitatively by two different experts on their respective systems. Polar map and functional analysis was performed in both softwares and the results were compared. Results: The concordance between the two experts qualitatively was seen in 78/93(84%) coronary territories. The polar map defects were comparable in LAD (r-value of 0.87) and LCX (r-value of 0.76) territories whereas RCA defects (r-value of 0.04) were not at all correlating. The defect severity showed concordance in 68/93 (73%) coronary territories. There was concordance between 4DMSPECT and the qualitative interpretation in 84/93 (90%) coronary territories whereas ECT showed concordance in only 70/93(75%) coronary territories. The overall sensitivity is marginally higher for ECT (100% vs. 96%) but the overall specificity is much higher with 4 DMSPECT (88% vs. 65%). ESV showed good correlation(r=0.94) of the two softwares with no significant difference in means. EDV and LVEF although had good correlation(r = 0.96 and 0.89) showed high difference in means (p<0.01). Conclusion: Between 4D-MSPECT and ECT, 4D-MSPECT is marginally superior to ECT with reference to qualitative interpretation in view of better specificity. The LVEF values between the two softwares should also not be used interchangeably. (author)

  15. Regulation of FeLV-945 by c-Myb binding and CBP recruitment to the LTR

    Directory of Open Access Journals (Sweden)

    Finstad Samantha L

    2004-09-01

    Full Text Available Abstract Background Feline leukemia virus (FeLV induces degenerative, proliferative and malignant hematologic disorders in its natural host, the domestic cat. FeLV-945 is a viral variant identified as predominant in a cohort of naturally infected animals. FeLV-945 contains a unique sequence motif in the long terminal repeat (LTR comprised of a single copy of transcriptional enhancer followed by a 21-bp sequence triplicated in tandem. The LTR is precisely conserved among independent cases of multicentric lymphoma, myeloproliferative disease and anemia in animals from the cohort. The 21-bp triplication was previously shown to act as a transcriptional enhancer preferentially in hematopoietic cells and to confer a replicative advantage. The objective of the present study was to examine the molecular mechanism by which the 21-bp triplication exerts its influence and the selective advantage responsible for its precise conservation. Results Potential binding sites for the transcription factor, c-Myb, were identified across the repeat junctions of the 21-bp triplication. Such sites would not occur in the absence of the repeat; thus, a requirement for c-Myb binding to the repeat junctions of the triplication would exert a selective pressure to conserve its sequence precisely. Electrophoretic mobility shift assays demonstrated specific binding of c-Myb to the 21-bp triplication. Reporter gene assays showed that the triplication-containing LTR is responsive to c-Myb, and that responsiveness requires the presence of both c-Myb binding sites. Results further indicated that c-Myb in complex with the 21-bp triplication recruits the transcriptional co-activator, CBP, a regulator of normal hematopoiesis. FeLV-945 replication was shown to be positively regulated by CBP in a manner dependent on the presence of the 21-bp triplication. Conclusion Binding sites for c-Myb across the repeat junctions of the 21-bp triplication may account for its precise conservation in

  16. Feline immunodeficiency virus (FIV, feline leukaemia virus (FeLV and Leishmania sp. in domestic cats in the Midwest of Brazil

    Directory of Open Access Journals (Sweden)

    Daniella Poffo

    Full Text Available ABSTRACT: This search aimed to investigate FIV and FeLV infections in domestic cats, analysing the epidemiological profile of the disease as well as additional infection with Leishmania sp. We evaluated 88 domestic cats for the presence of FIV, FeLV and Leishmania sp. infection. Eleven (12.5% cats were positive for FIV infection, four (4.5% were positive for FeLV, and two were co-infected. However, none was infected with Leishmania sp. The prevalence for FIV infection was higher than FeLV, and those observed in other regions, but no factor was associated with the infection by FIV and FeLV in this study.

  17. Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV-S3, HV-S3A and HV-S3B Exhaust Systems

    Energy Technology Data Exchange (ETDEWEB)

    Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-18

    Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 μm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

  18. 42 CFR 460.90 - PACE benefits under Medicare and Medicaid.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE benefits under Medicare and Medicaid. 460.90 Section 460.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... FOR THE ELDERLY (PACE) PACE Services § 460.90 PACE benefits under Medicare and Medicaid. If a Medicare...

  19. Information-Quality based LV-Grid-Monitoring Framework and its Application to Power-Quality Control

    DEFF Research Database (Denmark)

    Findrik, Mislav; Kristensen, Thomas le Fevre; Hinterhofer, Thomas

    2015-01-01

    The integration of unpredictable renewable energy sources into the low voltage (LV) power grid results in new challenges when it comes to ensuring power quality in the electrical grid. Addressing this problem requires control of not only the secondary substation but also control of flexible assets...... inside the LV grid. In this paper we investigate how the flexibility information of such assets can be accessed by the controller using heterogeneous off-the-shelf communication networks. To achieve this we develop an adaptive monitoring framework, through which the controller can subscribe to the assets......' flexibility information through an API. We define an information quality metric making the monitoring framework able to adapt information access strategies to ensure the information is made available to the controller with the highest possible information quality. To evaluate the monitoring framework...

  20. Physiological and perceptual responses of sedentary women while walking at a self-selected pace

    Directory of Open Access Journals (Sweden)

    Tatiane Hallage

    2007-06-01

    Full Text Available The purpose of this study was to investigate the physiological and perceptual responses of sedentary women while walking at a self-selected pace. The sample was made up of forty-one women with a median age of 32.6 ± 8.6 years. Subjects underwent an incremental test until exhaustion on a treadmill in order to determine their maximum physiological and perceptual responses. The subjects then a 20-minute walking test at their self-selected pace to determine physiological and perceptual responses. Descriptive analysis was in the form of measures of central tendency, variability and relative frequency. Mean exercise intensity during the walking bout was 57.3 ± 12.1% of peak oxygen consumption (VO2peak and 74.4 ± 9.3% of peak heart rate (HRpeak, corresponding to 88.4 ± 19.8% and 85.6 ± 21.6% of the fi gures obtained at ventilatory threshold (VT, respectively. Nevertheless, the rating of perceived effort (RPE and affective valence (AV during the walking session returned mean values of 11.9 ± 2.1 and 2.4 ± 2.0, which correspond to 100.7 ± 20.0% and 96.0 ± 2.0% of the fi gures obtained at VT, respectively. In conclusion, the exercise intensity that was self-selected by this group of sedentary women meets current recommendations for moderate intensity exercise and was associated with increased pleasure.RESUMO O objetivo desse estudo foi verifi car os parâmetros fi siológicos e perceptivos durante a realização de caminhada de intensidade preferida por mulheres adultas, previamente sedentárias. Foram investigados 41 sujeitos (idade 32,6 ± 8,6 anos, os quais realizaram, inicialmente, um teste de esteira incremental até a exaustão para a determinação de respostas fi siológicas e perceptivas máximas e, posteriormente, um teste de caminhada em esteira por 20 minutos em uma intensidade auto-selecionada, no qual parâmetros fi siológicos e perceptivos foram obtidos. Medidas de tendência central e variabilidade foram empregadas para a an

  1. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang; Feng, Jianlin; Lloyd, Michael S.; Chen, Ji

    2012-01-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  2. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang [First Affiliated Hospital of Nanjing Medical University, Department of Cardiology, Nanjing, Jiangsu (China); Feng, Jianlin [First Affiliated Hospital of Nanjing Medical University, Department of Nuclear Medicine, Nanjing, Jiangsu (China); Lloyd, Michael S. [Emory University School of Medicine, Division of Cardiology, Atlanta, GA (United States); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-07-15

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  3. Effective RNA-silencing strategy of Lv-MSTN/GDF11 gene and its effects on the growth in shrimp, Litopenaeus vannamei.

    Science.gov (United States)

    Lee, Ji-Hyun; Momani, Jalal; Kim, Young Mog; Kang, Chang-Keun; Choi, Jung-Hwa; Baek, Hae-Ja; Kim, Hyun-Woo

    2015-01-01

    Myostatin (MSTN), also known as GDF8, is a member of the transforming growth factor-β (TGF-β) superfamily and plays an important role in muscle growth, development, and differentiation. Recently, Lv-MSTN/GDF11, the primitive isoform of MSTN and GDF11, was identified from the shrimp Litopenaeus vannamei. The major production site for Lv-MSTN/GDF11 is in the heart, not the tail muscle, which differs from MSTNs in mammals. Among the three injected RNAs, long dsRNA was the most effective for Lv-MSTN/GDF11 knockdown and transcripts of Lv-MSTN/GDF11 decreased in both the heart (88.85%) and skeletal muscles (43.36%) 72h after injection of 10pmol of long dsRNA. We also found that higher doses of dsRNA did not lead to greater decreases in Lv-MSTN/GDF11 transcripts for amounts between 1pmol and 100pmol. Injection of Lv-MSTN/GDF11 dsRNA did not affect the upregulation of the skeletal actin gene (Lv-ACTINSK) in the tail muscle, but the expression of cytoplasmic and cardiac actins were upregulated in both the heart and tail muscle. Over the course of 8weeks of dsRNA injection, considerably higher mortality (~71%) was seen in the dsRNA-injected group compared to the control group (40%). Surviving shrimp in the dsRNA injected group had a lower growth rate due to the adverse effects of Lv-MSTN/GDF11 knockdown. Lv-MSTN/GDF11 appears to be involved in muscular or neuronal development, but not in doubling muscle fibers, as is the case with mammalian MSTN. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The solarPACES strategy for the solar thermal breakthrough

    International Nuclear Information System (INIS)

    Burch, G.D.; Grasse, W.

    1997-01-01

    IEA(International Energy Agency)/SolarPACES(Solar Power and Chemical Energy systems)represents a world wide coalition for information sharing and collaboration on applications of concentrated solar energy. The current SolarPACES community has built up solar thermal system know-how over 15 years, is operating the three main solar test centres in the world. Its main activities are in the following four fields: solar thermal electric power systems, solar chemistry, solar technology and advanced applications and non-technical activities. The article presents the talk on the strategy of solarPACES given at the International Workshop on applied solar energy held in Tashkent(Uzbekistan) in June 1997. (A.A.D.)

  5. Pace: an advanced structure for handling multi-technique NDT

    International Nuclear Information System (INIS)

    Mayos, M.; Guisnel, F.

    1995-08-01

    The growing extent and complexity of NDT data analysis has reached a stage where dedicated systems are required. In the context of a European research program, EDF participated from 1992 to 1994 in one of the first international projects in this field, TRAPPIST and, in 1993, began developing An application for the electricity generating industry, giving rise to the PACE project. The prime objective specially targets the French electricity generating industry, where PACE was to be the reference system for analysis of NDE data concerning EdF power plants. The second objective is to promote the adoption of PACE by other industrial sectors and other countries. The analysis of needs shows that the required system must be designed to analyze data from widely different sources. The PACE entry point consequently has to be a standard format compatible with geometrical data as well as those provided by NDT. The TRAPPIST format constitutes the first version of this standard and is the first step towards European standardization in this respect. Consideration of the different user modes defined for PACE led to the design of a 2-part user structure comprising a database management system (Ingres/Windows 4GL) and a display/processing tool (AVS), also usable to construct analysis scenarios. The structure of PACE is defined nd seems well suited to industrial requirements, but before it is possible to proceed further towards its adoption for actual power plant inspections, it has to be validated on a more realistic application, the eddy current and ultrasonic testing of a full-scale T-joint. This is already under way, whilst work on format standardization and industrialization preparatory procedures are proceeding in parallel. (authors). 4 refs., 6 figs

  6. International piping benchmarks: Use of simplified code PACE 2

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom)

    1979-06-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  7. International piping benchmarks: Use of simplified code PACE 2

    International Nuclear Information System (INIS)

    Boyle, J.; Spence, J.; Blundell, C.

    1979-01-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  8. MFTF-B PACE tests and final cost report

    International Nuclear Information System (INIS)

    Krause, K.H.; Kozman, T.A.; Smith, J.L.; Horan, R.J.

    1986-10-01

    The Mirror Fusion Test Facility (MFTF-B) construction project was successfully completed in February 1986, with the conclusion of the Plant and Capital Equipment (PACE) Tests. This series of tests, starting in September 1985 and running through February 1986, demonstrated the overall machine capabilities and special facilities accomplishments for the Mirror Fusion Test Facility Project

  9. Self-Paced Physics, Segments 19-23.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Five study segments of the Self-Paced Physics Course materials are presented in this fourth problems and solutions book used as a part of student course work. The subject matter is related to electric charges, insulators, Coulomb's law, electric fields, lines of force, solid angles, conductors, motion of charged particles, dipoles, electric flux,…

  10. The Effects of Self-Paced Blended Learning of Mathematics

    Science.gov (United States)

    Balentyne, Phoebe; Varga, Mary Alice

    2016-01-01

    As online and blended learning gain more popularity in education, it becomes more important to understand their effects on student learning. The purpose of this study was to explore the effects of self-paced blended learning of mathematics on the attitudes and achievement of 26 high ability middle school students, and investigate the relationship…

  11. Hardware packet pacing using a DMA in a parallel computer

    Science.gov (United States)

    Chen, Dong; Heidelberger, Phillip; Vranas, Pavlos

    2013-08-13

    Method and system for hardware packet pacing using a direct memory access controller in a parallel computer which, in one aspect, keeps track of a total number of bytes put on the network as a result of a remote get operation, using a hardware token counter.

  12. PACE: A dynamic programming algorithm for hardware/software partitioning

    DEFF Research Database (Denmark)

    Knudsen, Peter Voigt; Madsen, Jan

    1996-01-01

    This paper presents the PACE partitioning algorithm which is used in the LYCOS co-synthesis system for partitioning control/dataflow graphs into hardware and software parts. The algorithm is a dynamic programming algorithm which solves both the problem of minimizing system execution time...

  13. Self-Paced Physics, Segments 24-27.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this fifth problems and solutions book used as a part of student course work. The subject matter is related to work in electric fields, potential differences, parallel plates, electric potential energies, potential gradients, capacitances, and capacitor circuits.…

  14. PACES: A Model of Student Well-Being

    Science.gov (United States)

    Nelson, Mark D.; Tarabochia, Dawn W.; Koltz, Rebecca L.

    2015-01-01

    School counselors design, deliver, and evaluate comprehensive, developmental school counseling programs that are focused on enhancing student development and success. A model of student well-being, known as PACES, is defined and described that consists of five distinct and interactive domains: physical, affective, cognitive, economic, and social.…

  15. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  16. Keeping Pace with K-12 Online Learning, 2016

    Science.gov (United States)

    Gemin, Butch; Pape, Larry

    2017-01-01

    "Keeping Pace with K-12 Online Learning 2016" marks the thirteenth consecutive year Evergreen has published its annual research of the K-12 education online learning market. The thirteen years of researching, writing and publishing this report represents a time of remarkable change. There has been a constant presence that has become the…

  17. Optimizing Classroom Instruction through Self-Paced Learning Prototype

    Science.gov (United States)

    Bautista, Romiro G.

    2015-01-01

    This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students' learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was…

  18. Amplitude and phase dynamics associated with acoustically paced finger tapping

    NARCIS (Netherlands)

    Boonstra, T.W.; Daffertshofer, A.; Peper, C.E.; Beek, P.J.

    2006-01-01

    To gain insight into the brain activity associated with the performance of an acoustically paced synchronization task, we analyzed the amplitude and phase dynamics inherent in magnetoencephalographic (MEG) signals across frequency bands in order to discriminate between evoked and induced responses.

  19. Self-Paced Physics, Segments 28-31.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this sixth problems and solutions book used as a part of student course work. The subject matter is related to electric currents, current densities, resistances, Ohm's law, voltages, Joule heating, electromotive forces, single loop circuits, series and parallel…

  20. Introduction to Physics (Mechanics): A Semi-Self Paced Approach.

    Science.gov (United States)

    Schlenker, Richard M.

    Presented is a guide for an introductory college level physics course in mechanics. The course is contract graded and allows students to proceed at their own pace; however, lectures, problem solving sessions, and laboratory sessions are included. Students on an independent basis review video tapes, film loops, library study, and conduct an…

  1. Design Recommendations for Self-Paced Online Faculty Development Courses

    Science.gov (United States)

    Rizzuto, Melissa

    2017-01-01

    An increased need for self-paced, online professional development opportunities in higher education has emerged from a variety of factors including dispersed geographic locations of faculty, full teaching loads, and institutional evaluation requirements. This article is a report of the examination of the design and evaluation of a self-paced…

  2. Self-Paced Physics, Segments 37-40.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this eighth problems and solutions book used as a part of course assignments. The content is related to magnetic induction, Faraday's law, induced currents, Lenz's law, induced electromotive forces, time-varying magnetic fields, self-inductance, inductors,…

  3. Gait Coordination After Stroke: Benefits of Acoustically Paced Treadmill Walking

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.C.; Kwakkel, G.; van Wieringen, P.C.W.; Beek, P.J.

    2007-01-01

    Background and Purpose: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. Participants: Ten people after stroke volunteered for the

  4. Gait coordination after stroke: benefits of acoustically paced treadmill walking.

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.; Kwakkel, G.; Wieringen, P.C. van; Beek, P.J.

    2007-01-01

    BACKGROUND AND PURPOSE: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. PARTICIPANTS: Ten people after stroke volunteered for the

  5. LV reverse remodeling imparted by aortic valve replacement for severe aortic stenosis; is it durable? A cardiovascular MRI study sponsored by the American Heart Association

    Directory of Open Access Journals (Sweden)

    Caruppannan Ketheswaram

    2011-04-01

    Full Text Available Abstract Background In patients with severe aortic stenosis (AS, long-term data tracking surgically induced effects of afterload reduction on reverse LV remodeling are not available. Echocardiographic data is available short term, but in limited fashion beyond one year. Cardiovascular MRI (CMR offers the ability to serially track changes in LV metrics with small numbers due to its inherent high spatial resolution and low variability. Hypothesis We hypothesize that changes in LV structure and function following aortic valve replacement (AVR are detectable by CMR and once triggered by AVR, continue for an extended period. Methods Tweny-four patients of which ten (67 ± 12 years, 6 female with severe, but compensated AS underwent CMR pre-AVR, 6 months, 1 year and up to 4 years post-AVR. 3D LV mass index, volumetrics, LV geometry, and EF were measured. Results All patients survived AVR and underwent CMR 4 serial CMR's. LVMI markedly decreased by 6 months (157 ± 42 to 134 ± 32 g/m2, p 2. Similarly, EF increased pre to post-AVR (55 ± 22 to 65 ± 11%,(p 2. LV stroke volume increased rapidly from pre to post-AVR (40 ± 11 to 44 ± 7 ml, p Conclusion After initial beneficial effects imparted by AVR in severe AS patients, there are, as expected, marked improvements in LV reverse remodeling. Via CMR, surgically induced benefits to LV structure and function are durable and, unexpectedly express continued, albeit markedly incomplete improvement through 4 years post-AVR concordant with sustained improved clinical status. This supports down-regulation of both mRNA and MMP activity acutely with robust suppression long term.

  6. A Scenario-Based Approach for Energy Storage Capacity Determination in LV Grids with High PV Penetration

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Yang, Guangya

    2014-01-01

    In this paper a new method is proposed to determine the minimum energy storage required to be installed at different locations of a low voltage (LV) grid in order to prevent the overvoltage due to high residential photovoltaic (PV) penetration. The method is based on the voltage sensitivity...... with different occurrence probabilities without involving the time-series studies problems. The proposed method is capable of modeling output power of PV panels with different orientations as well as different electric vehicle (EV) charging patterns....

  7. Rhythm perturbations in acoustically paced treadmill walking after stroke.

    Science.gov (United States)

    Roerdink, Melvyn; Lamoth, Claudine J C; van Kordelaar, Joost; Elich, Peter; Konijnenbelt, Manin; Kwakkel, Gert; Beek, Peter J

    2009-09-01

    In rehabilitation, acoustic rhythms are often used to improve gait after stroke. Acoustic cueing may enhance gait coordination by creating a stable coupling between heel strikes and metronome beats and provide a means to train the adaptability of gait coordination to environmental changes, as required in everyday life ambulation. To examine the stability and adaptability of auditory-motor synchronization in acoustically paced treadmill walking in stroke patients. Eleven stroke patients and 10 healthy controls walked on a treadmill at preferred speed and cadence under no metronome, single-metronome (pacing only paretic or nonparetic steps), and double-metronome (pacing both footfalls) conditions. The stability of auditory-motor synchronization was quantified by the variability of the phase relation between footfalls and beats. In a separate session, the acoustic rhythms were perturbed and adaptations to restore auditory-motor synchronization were quantified. For both groups, auditory-motor synchronization was more stable for double-metronome than single-metronome conditions, with stroke patients exhibiting an overall weaker coupling of footfalls to metronome beats than controls. The recovery characteristics following rhythm perturbations corroborated the stability findings and further revealed that stroke patients had difficulty in accelerating their steps and instead preferred a slower-step response to restore synchronization. In gait rehabilitation practice, the use of acoustic rhythms may be more effective when both footfalls are paced. In addition, rhythm perturbations during acoustically paced treadmill walking may not only be employed to evaluate the stability of auditory-motor synchronization but also have promising implications for evaluation and training of gait adaptations in neurorehabilitation practice.

  8. Pacing, Pixels, and Paper: Flexibility in Learning Words from Flashcards

    Directory of Open Access Journals (Sweden)

    Kara Sage

    2016-08-01

    Full Text Available The present study focused on how self-control over pace might help learners successfully extract information from digital learning aids. Past research has indicated that too much control over pace can be overwhelming, but too little control over pace can be ineffective. Within the popular self-testing domain of flashcards, we sought to elucidate the optimal level of user control for digital learning and compare learning outcomes between paper and digital flashcards. College students learned vocabulary from paper flashcards or one of several digital flashcard versions and were scored on their memory recall and asked about their perceptions of the learning process. With digital flashcards, students were randomly assigned to an automatic slideshow of cards with no user control, automatic slideshow with pre-set pauses, automatic slideshow where users could press the spacebar to pause at any time, or a self-paced slideshow with complete user control. Users reported feeling more in control when indeed having some control, but ultimately memory recall, cognitive load, and satisfaction were similar across the five versions. However, memory recall was positively related to user satisfaction with their specific flashcard set, and negatively related to users’ perceived mental effort and difficulty. Notably, whether paper or digital, students showed individual variability in how they advanced through the words. This research adds to the educational literature by suggesting that paper and digital flashcards are equally viable options for students. Given differences between individual users and the connection between satisfaction and recall, individualistic options that offer, but do not force, some control over pace seem ideal. Paper flashcards may already include such options, and e-flashcards should offer similar adaptive features to appeal to a wide variety of users.

  9. Hematological findings and factors associated with feline leukemia virus (FeLV and feline immunodeficiency virus (FIV positivity in cats from southern Brazil

    Directory of Open Access Journals (Sweden)

    Fernanda V.A. da Costa

    Full Text Available ABSTRACT: Using a retrospective study, 493 cats tested for FeLV and FIV were selected for analysis of the association between hematologic findings and positivity at immunoassay test. Individual and hematologic variables were assessed considering the influence of results using univariate and multivariate logistic regression analysis. Out 153 of the 493 cats were positive for FeLV (31%, 50 were positive for FIV (10.1% and 22 were positive for both FIV and FeLV (4.4%. Multivariate analysis detected significant associations between FeLV infection and age below 1 year (p=0.01, age from 1 to 10 years (p=0.03, and crossbreed (p=0.04. Male cats were more likely to be FIV-positive (p=0.002. Regarding hematological changes, FeLV-positive cats have higher odds to anemia, leukopenia and lymphopenia than FeLV-negative cats. FIV-positive cats are more likely to have anemia than negative. Identification of associated factors related to animal status and correlation of hematological disorders with infection by retroviruses in cats could be useful for detecting these retroviral diseases in cats.

  10. Litopenaeus vannamei sterile-alpha and armadillo motif containing protein (LvSARM is involved in regulation of Penaeidins and antilipopolysaccharide factors.

    Directory of Open Access Journals (Sweden)

    Pei-Hui Wang

    Full Text Available The Toll-like receptor (TLR-mediated NF-κB pathway is tightly controlled because overactivation may result in severe damage to the host, such as in the case of chronic inflammatory diseases and cancer. In mammals, sterile-alpha and armadillo motif-containing protein (SARM plays an important role in negatively regulating this pathway. While Caenorhabditis elegans SARM is crucial for an efficient immune response against bacterial and fungal infections, it is still unknown whether Drosophila SARM participates in immune responses. Here, Litopenaeus vannamei SARM (LvSARM was cloned and functionally characterized. LvSARM shared signature domains with and exhibited significant similarities to mammalian SARM. Real-time quantitative PCR analysis indicated that the expression of LvSARM was responsive to Vibrio alginolyticus and white spot syndrome virus (WSSV infections in the hemocyte, gill, hepatopancreas and intestine. In Drosophila S2 cells, LvSARM was widely distributed in the cytoplasm and could significantly inhibit the promoters of the NF-κB pathway-controlled antimicrobial peptide genes (AMPs. Silencing of LvSARM using dsRNA-mediated RNA interference increased the expression levels of Penaeidins and antilipopolysaccharide factors, which are L.vannamei AMPs, and increased the mortality rate after V. alginolyticus infection. Taken together, our results reveal that LvSARM may be a novel component of the shrimp Toll pathway that negatively regulates shrimp AMPs, particularly Penaeidins and antilipopolysaccharide factors.

  11. Interneta sociālie tīkli draugiem.lv, mammam/tetiem.lv un twitter.com kā reklāmas nesēji Latvijā (2009.gads)

    OpenAIRE

    Vismane, Inese

    2010-01-01

    Maģistra darba tēma ir „Interneta sociālie tīkli draugiem.lv, mammam/tetiem.lv un twitter.com kā reklāmas nesēji Latvijā (2009.gads)”. Darba mērķis ir izpētīt Latvijas interneta sociālo tīklu vidi kā potenciāli augošu un reklāmai piemērotu, kā arī izpētīt pamanāmākos reklāmas gadījumus šajos portālos. Teorijas daļā tiek apskatīta Web 2.0 ēra, interneta reklāmas un sociālo mediju mārketinga īpatnības, sociālo tīklu fenomens un teorijas, Latvijas reklāmas tirgus un auditorija, kā arī sociāl...

  12. Exercise capacity and N-terminal pro-brain natriuretic peptide levels with biventricular vs. right ventricular pacing for atrioventricular block: results from the PREVENT-HF German Substudy.

    Science.gov (United States)

    Stockburger, Martin; de Teresa, Eduardo; Lamas, Gervasio; Desaga, Martin; Koenig, Carsten; Habedank, Dirk; Cobo, Erik; Navarro, Xavier; Wiegand, Uwe

    2014-01-01

    Previous studies showed unfavourable effects of right ventricular (RV) pacing. Ventricular pacing (VP), however, is required in many patients with atrioventricular (AV) block. The PREVENT-HF study explored left ventricular (LV) remodelling during RV vs. biventricular (BIV) pacing in AV block without advanced heart failure. The pre-specified PREVENT-HF German Substudy examined exercise capacity and N-terminal pro-brain natriuretic peptide (NT-proBNP). Patients with expected VP ≥80% were randomized to RV or BIV pacing. Endpoints were peak oxygen uptake (pVO2), oxygen uptake at the anaerobic threshold (VO2AT), ventilatory efficiency (VE/VCO2), and logNT-proBNP. Considering crossover, intention to treat (ITT), and on-treatment (OT) analyses of covariance (ANCOVA) were performed. For exercise testing 44 (RV: 25, BIV: 19), and for NT-proBNP 53 patients (RV: 29, BIV: 24) were included. The ITT analysis revealed significant differences in pVO2 [ANCOVA effect 2.83 mL/kg/min, confidence interval (CI) 0.83-4.91, P = 0.007], VO2AT (ANCOVA effect 2.14 mL/min/k, CI 0.14-4.15, P = 0.03), and VE/VCO2 (ANCOVA effect -5.46, CI -10.79 to -0.13, P = 0.04) favouring BIV randomization. The significant advantage in pVO2 persisted in OT analysis, while VO2AT and VE/VCO2 showed trends favouring BIV pacing. LogNT-proBNP did not differ between groups. (ITT: ANCOVA effect 0.008, CI -0.40 to +0.41, P = 0.97; OT: ANCOVA effect -0.03, CI -0.44 to 0.30, P = 0.90). Our study suggests that BIV pacing produces better exercise capacity over 1 year compared with RV pacing in patients without advanced heart failure and AV block. In contrast, we observed no significant changes of NT-proBNP. Larger trials will allow appraising the clinical usefulness of BIV pacing in AV block. ClinicalTrials.gov Identifier: NCT00170326.

  13. Laboratorios virtuales (LV como apoyo a las prácticas a distancia y presenciales en ingeniería

    Directory of Open Access Journals (Sweden)

    Francis Castellanos

    2010-01-01

    Full Text Available El presente artículo tiene como propósito mostrar los procesos inherentes a cada una de las etapas de diseño y desarrollo en un Laboratorio Virtual, LV, y más específicamente para el laboratorio redes convergentes de la Institución. Durante la investigación, se desarrolló una metodología basada en los lineamientos del PMI (Project Management Institute que servirá como base para la creación de futuros laboratorios virtuales en cualquier área del conocimiento. Para el acceso de los laboratorios se desarrolló la herramienta de Software Vlab, como una plataforma integradora de laboratorios virtuales para la Institución. Los LV son simulaciones consideradas como una alternativa pedagógica para el desarrollo de prácticas a distancia o como apoyo a las prácticas en la presencialidad, que ofrecen a los estudiantes la oportunidad de adquirir destrezas y habilidades en el manejo de materiales y equipos relacionados con las áreas de su campo de formación, sin restricción de tiempo o espacio.

  14. Project of Ariane 5 LV family advancement by use of reusable fly-back boosters (named “Bargouzine”)

    Science.gov (United States)

    Sumin, Yu.; Bonnal, Ch.; Kostromin, S.; Panichkin, N.

    2007-12-01

    The paper concerns possible concept variants of a partially reusable Heavy-Lift Launch Vehicle derived from the advanced basic launcher (Ariane-2010) by means of substitution of the EAP Solid Rocket Boosters for a Reusable Starting Stage consisting two Liquid-propellant Reusable Fly-Back Boosters called "Bargouzin". This paper describes the status of the presently studied RFBB concepts during its three phases. The first project phase was dedicated to feasibility expertise of liquid-rocket reusable fly-back boosters ("Baikal" type) utilization for heavy-lift space launch vehicle. The design features and main conclusions are presented. The second phase has been performed with the purpose of selection of preferable concept among the alternative ones for the future Ariane LV modernization by using RFBB instead of EAP Boosters. The main requirements, logic of work, possible configuration and conclusion are presented. Initial aerodynamic, ballistic, thermoloading, dynamic loading, trade-off and comparison analysis have been performed on these concepts. The third phase consists in performing a more detailed expertise of the chosen LV concept. This part summarizes some of the more detailed results related to flight performance, system mass, thermoprotection system, aspects of technologies, ground complex modification, comparison analyses and conclusion.

  15. Zygotic LvBMP5-8 is required for skeletal patterning and for left-right but not dorsal-ventral specification in the sea urchin embryo.

    Science.gov (United States)

    Piacentino, Michael L; Chung, Oliver; Ramachandran, Janani; Zuch, Daniel T; Yu, Jia; Conaway, Evan A; Reyna, Arlene E; Bradham, Cynthia A

    2016-04-01

    Skeletal patterning in the sea urchin embryo requires coordinated signaling between the pattern-dictating ectoderm and the skeletogenic primary mesenchyme cells (PMCs); recent studies have begun to uncover the molecular basis for this process. Using an unbiased RNA-Seq-based screen, we have previously identified the TGF-ß superfamily ligand, LvBMP5-8, as a skeletal patterning gene in Lytechinus variegatus embryos. This result is surprising, since both BMP5-8 and BMP2/4 ligands have been implicated in sea urchin dorsal-ventral (DV) and left-right (LR) axis specification. Here, we demonstrate that zygotic LvBMP5-8 is required for normal skeletal patterning on the left side, as well as for normal PMC positioning during gastrulation. Zygotic LvBMP5-8 is required for expression of the left-side marker soxE, suggesting that LvBMP5-8 is required for left-side specification. Interestingly, we also find that LvBMP5-8 knockdown suppresses serotonergic neurogenesis on the left side. While LvBMP5-8 overexpression is sufficient to dorsalize embryos, we find that zygotic LvBMP5-8 is not required for normal DV specification or development. In addition, ectopic LvBMP5-8 does not dorsalize LvBMP2/4 morphant embryos, indicating that, in the absence of BMP2/4, BMP5-8 is insufficient to specify dorsal. Taken together, our data demonstrate that zygotic LvBMP5-8 signaling is essential for left-side specification, and for normal left-side skeletal and neural patterning, but not for DV specification. Thus, while both BMP2/4 and BMP5-8 regulate LR axis specification, BMP2/4 but not zygotic BMP5-8 regulates DV axis specification in sea urchin embryos. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Effect of age and performance on pacing of marathon runners

    Directory of Open Access Journals (Sweden)

    Nikolaidis PT

    2017-08-01

    Full Text Available Pantelis Theodoros Nikolaidis,1 Beat Knechtle2,3 1Exercise Physiology Laboratory, Attiki, Greece; 2Gesundheitszentrum St. Gallen, St. Gallen, 3Institute of Primary Care, University of Zurich, Zurich, Switzerland Abstract: Pacing strategies in marathon runners have previously been examined, especially with regard to age and performance level separately. However, less information about the age × performance interaction on pacing in age-group runners exists. The aim of the present study was to examine whether runners with similar race time and at different age differ for pacing. Data (women, n=117,595; men, n=180,487 from the “New York City Marathon” between 2006 and 2016 were analyzed. A between–within subjects analysis of variance showed a large main effect of split on race speed (p<0.001, η2=0.538 with the fastest speed in the 5–10 km split and the slowest in the 35–40 km. A small sex × split interaction on race speed was found (p<0.001, η2=0.035 with men showing larger increase in speed at 5 km and women at 25 km and 40 km (end spurt. An age-group × performance group interaction on Δspeed was shown for both sexes at 5 km, 10 km, 15 km, 20 km, 25 km, 30 km, 35 km, and 40 km (p<0.001, 0.001≤η2≤0.004, where athletes in older age-groups presented a relatively more even pace compared with athletes in younger age-groups, a trend that was more remarkable in the relatively slow performance groups. So far, the present study is the first one to observe an age × performance interaction on pacing; ie, older runners pace differently (smaller changes than younger runners with similar race time. These findings are of great practical interest for coaches working with marathon runners of different age, but similar race time. Keywords: running, master athlete, endurance, aerobic capacity, fatigue, gender, race time

  17. Permanent pacing in infants and children: A single center experience in implantation and follow up

    Directory of Open Access Journals (Sweden)

    Rania Samir

    2011-09-01

    Conclusion: Permanent pacing in pediatric age group is relatively safe. However, there is substantial higher incidence of suboptimal pacing parameters and pacing system failures especially in younger and smaller children. Epicardial steroid eluting leads are comparable to endocardial steroid eluting leads in performance.

  18. Optimal pacing strategy: From theoretical modeling to reality in 1500m speed skating

    NARCIS (Netherlands)

    Hettinga, F.J.; de Koning, J.J.; Schmidt, L.J.I.; Wind, N.A.C.; McIntosh, B.; Foster, C.

    2011-01-01

    Purpose: Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  19. Optimal pacing strategy : from theoretical modelling to reality in 1500-m speed skating

    NARCIS (Netherlands)

    Hettinga, F. J.; De Koning, J. J.; Schmidt, L. J. I.; Wind, N. A. C.; MacIntosh, B. R.; Foster, C.

    Purpose Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  20. Predicting Successful Completion Using Student Delay Indicators in Undergraduate Self-Paced Online Courses

    Science.gov (United States)

    Lim, Janine M.

    2016-01-01

    Self-paced online courses meet flexibility and learning needs of many students, but skepticism persists regarding the quality and the tendency for students to procrastinate in self-paced courses. Research is needed to understand procrastination and delay patterns of students in online self-paced courses to predict successful completion and…

  1. Serological survey of Toxoplasma gondii, Dirofilaria immitis, Feline Immunodeficiency Virus (FIV) and Feline Leukemia Virus (FeLV) infections in pet cats in Bangkok and vicinities, Thailand.

    Science.gov (United States)

    Sukhumavasi, Woraporn; Bellosa, Mary L; Lucio-Forster, Araceli; Liotta, Janice L; Lee, Alice C Y; Pornmingmas, Pitcha; Chungpivat, Sudchit; Mohammed, Hussni O; Lorentzen, Leif; Dubey, J P; Bowman, Dwight D

    2012-08-13

    The seroprevalence of Toxoplasma gondii, Dirofilaria immitis (heartworm), feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infections was examined using serum or plasma samples from 746 pet cats collected between May and July 2009 from clinics and hospitals located in and around Bangkok, Thailand. The samples were tested for heartworm, FIV, and FeLV using a commercial ELISA. Of the 746 samples, 4.6% (34/746) were positive for heartworm antigen, 24.5% (183/746) had circulating FeLV antigen, and 20.1% (150/746) had antibodies against FIV. In addition, the first 348 submitted samples were tested for T. gondii antibodies using a modified agglutination test (MAT, cut off 1:25); 10.1% (35/348) were seropositive. Of the 348 cats sampled for all four pathogens, 11, 10, and 1 were positive for T. gondii antibodies and FIV antibodies, FeLV antigen, or D. immitis antigen, respectively. Of the 35 T. gondii-seropositive cats, 42.9% (15/35) were co-infected with at least one of the other three pathogens. The presence of antibodies to FIV was significantly associated with both age and gender, while FeLV antigen presence was only associated with age. In the case of FIV, males were twice as likely to be infected as females, and cats over 10 years of age were 13.5 times more likely to be infected than cats less than 1 year of age. FeLV antigen was more common in younger cats, with cats over 10 years of age being 10 times less likely to be FeLV positive than cats under 1 year of age. This is the first survey for these four pathogens affecting feline health in Thailand. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. The pace of vocabulary growth helps predict later vocabulary skill

    Science.gov (United States)

    Rowe, Meredith L.; Raudenbush, Stephen W.; Goldin-Meadow, Susan

    2011-01-01

    Children vary widely in the rate at which they acquire words—some start slow and speed up, others start fast and continue at a steady pace. Do early developmental variations of this sort help predict vocabulary skill just prior to kindergarten entry? This longitudinal study starts by examining important predictors (SES, parent input, child gesture) of vocabulary growth between 14 and 46 months (n=62), and then uses growth estimates to predict children's vocabulary at 54 months. Velocity and acceleration in vocabulary development at 30 months predicted later vocabulary, particularly for children from low socioeconomic backgrounds. Understanding the pace of early vocabulary growth thus improves our ability to predict school readiness, and may help identify children at risk for starting behind. PMID:22235920

  3. Organizational Learning: Keeping Pace with Change through Action Learning

    OpenAIRE

    Yeadon-Lee, Annie

    2015-01-01

    In the current climate of economic ‘austerity’, organisational learning has increasingly gained importance, and a need for new ways of transferring learning has been identified. Organisational learning is seen as key to organisational success, ensuring both competitive advantage and organisational longevity. However, in order for organisations to keep pace with change they must not only strive to learn but also pay attention to how they might learn. A dominant view within the field of organis...

  4. Factors affecting the regulation of pacing: current perspectives

    Directory of Open Access Journals (Sweden)

    Mauger AR

    2014-09-01

    Full Text Available Alexis R Mauger Endurance Research Group, School of Sport and Exercise Sciences, Faculty of Science, University of Kent, Chatham, UK Abstract: During prolonged dynamic and rhythmic exercise, muscular pain and discomfort arises as a result of an increased concentration of deleterious metabolites. Sensed by peripheral nociceptors and transmitted via afferent feedback to the brain, this provides important information regarding the physiological state of the muscle. These sensations ultimately contribute to what is termed "exercise-induced pain". Despite being well recognized by athletes and coaches, and suggested to be integral to exercise performance, this construct has largely escaped attention in experimental work. This perspective article highlights the current understanding of pacing in endurance performance, and the causes of exercise-induced pain. A new perspective is described, which proposes how exercise-induced pain may be a contributing factor in helping individuals to regulate their work rate during exercise and thus provides an important construct in pacing. Keywords: pain, exercise-induced pain, discomfort, exercise performance, self-paced

  5. MRI with cardiac pacing devices – Safety in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko, E-mail: touko.kaasalainen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Physics, University of Helsinki (Finland); Pakarinen, Sami, E-mail: sami.pakarinen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Kivistö, Sari, E-mail: sari.kivisto@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Holmström, Miia, E-mail: miia.holmstrom@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Hänninen, Helena, E-mail: helena.hanninen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Peltonen, Juha, E-mail: juha.peltonen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki (Finland); Lauerma, Kirsi, E-mail: kirsi.lauerma@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Sipilä, Outi, E-mail: outi.sipila@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland)

    2014-08-15

    Objectives: The aim of this study was to introduce a single centre “real life” experience of performing MRI examinations in clinical practice on patients with cardiac pacemaker systems. Additionally, we aimed to evaluate the safety of using a dedicated safety protocol for these patients. Materials and methods: We used a 1.5 T MRI scanner to conduct 68 MRI scans of different body regions in patients with pacing systems. Of the cardiac devices, 32% were MR-conditional, whereas the remaining 68% were MR-unsafe. We recorded the functional parameters of the devices prior, immediately after, and approximately one month after the MRI scanning, and compared the device parameters to the baseline values. Results: All MRI examinations were completed safely, and each device could be interrogated normally following the MRI. We observed no changes in the programmed parameters of the devices. For most of the participants, the distributions of the immediate and one-month changes in the device parameters were within 20% of the baseline values, although some changes approached clinically important thresholds. Furthermore, we observed no differences in the variable changes between MR-conditional and MR-unsafe pacing systems, or between scans of the thorax area and other scanned areas. Conclusion: MRI in patients with MR-conditional pacing systems and selected MR-unsafe systems could be performed safely under strict conditions in this study.

  6. Optimizing classroom instruction through self-paced learning prototype

    Directory of Open Access Journals (Sweden)

    Romiro Gordo Bautista

    2015-09-01

    Full Text Available This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students’ learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was conducted, scored and analyzed which served as the basis in determining the initial learning schema of the respondents. A questionnaire was adopted to find the learning motivation of the students in science. Using Pearson-r correlation, it was found out that there is a highly significant relationship between their internal drive and their academic performance. Moreover, a post-test was conducted after self-paced learning prototype was used in the development of select topics in their curricular plot. It was found out that the students who experienced the self-paced learning prototype performed better in their academic performance as evidenced by the difference of their mean post-test results. ANCOVA results on the post-test mean scores of the respondents were utilized in establishing the causal-effect of the learning prototype to the academic performance of the students in Chemistry. A highly significant effect on their academic performance (R-square value of 70.7% and significant interaction of the models to the experimental grouping and mental abilities of the respondents are concluded in the study.

  7. Unilateral Laryngeal Pacing System and Its Functional Evaluation

    Directory of Open Access Journals (Sweden)

    Taiping Zeng

    2017-01-01

    Full Text Available Goal. To establish a reliable instrumental system for synchronized reactivation of a unilaterally paralyzed vocal fold and evaluate its functional feasibility. Methods. Unilateral vocal fold paralysis model was induced by destruction of the left recurrent laryngeal nerve (RLN in anesthetized dogs. With a micro controller-based electronic system, electromyography (EMG signals from cricothyroid (CT muscle on the ipsilateral side were recorded and used to trigger pacing of paralyzed vocalis muscles. The dynamic movement of vocal folds was continuously monitored using an endoscope, and the opening and closing of the glottis were quantified with customized imaging processing software. Results. The recorded video images showed that left side vocal fold was obviously paralyzed after destructing the RLN. Using the pacing system with feedback triggering EMG signals from the ipsilateral CT muscle, the paralyzed vocal fold was successfully reactivated, and its movement was shown to be synchronized with the healthy side. Significance. The developed unilateral laryngeal pacing system triggered by EMG from the ipsilateral side CT muscle could be successfully used in unilateral vocal fold paralysis with the advantage of avoiding disturbance to the healthy side muscles.

  8. Pacing and awareness: brain regulation of physical activity.

    Science.gov (United States)

    Edwards, A M; Polman, R C J

    2013-11-01

    The aim of this current opinion article is to provide a contemporary perspective on the role of brain regulatory control of paced performances in response to exercise challenges. There has been considerable recent conjecture as to the role of the brain during exercise, and it is now broadly accepted that fatigue does not occur without brain involvement and that all voluntary activity is likely to be paced at some level by the brain according to individualised priorities and knowledge of personal capabilities. This article examines the role of pacing in managing and distributing effort to successfully accomplish physical tasks, while extending existing theories on the role of the brain as a central controller of performance. The opinion proposed in this article is that a central regulator operates to control exercise performance but achieves this without the requirement of an intelligent central governor located in the subconscious brain. It seems likely that brain regulation operates at different levels of awareness, such that minor homeostatic challenges are addressed automatically without conscious awareness, while larger metabolic disturbances attract conscious awareness and evoke a behavioural response. This supports the view that the brain regulates exercise performance but that the interpretation of the mechanisms underlying this effect have not yet been fully elucidated.

  9. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Feng, Jianlin; Zhou, Yanli; Cao, Kejiang; Lloyd, Michael S; Chen, Ji

    2012-07-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4%) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI.

  10. No Evidence of XMRV or MuLV Sequences in Prostate Cancer, Diffuse Large B-Cell Lymphoma, or the UK Blood Donor Population

    Directory of Open Access Journals (Sweden)

    Mark James Robinson

    2011-01-01

    Full Text Available Xenotropic murine leukaemia virus-related virus (XMRV is a recently described retrovirus which has been claimed to infect humans and cause associated pathology. Initially identified in the US in patients with prostate cancer and subsequently in patients with chronic fatigue syndrome, doubt now exists that XMRV is a human pathogen. We studied the prevalence of genetic sequences of XMRV and related MuLV sequences in human prostate cancer, from B cell lymphoma patients and from UK blood donors. Nucleic acid was extracted from fresh prostate tissue biopsies, formalin-fixed paraffin-embedded (FFPE prostate tissue and FFPE B-cell lymphoma. The presence of XMRV-specific LTR or MuLV generic gag-like sequences was investigated by nested PCR. To control for mouse DNA contamination, a PCR that detected intracisternal A-type particle (IAP sequences was included. In addition, DNA and RNA were extracted from whole blood taken from UK blood donors and screened for XMRV sequences by real-time PCR. XMRV or MuLV-like sequences were not amplified from tissue samples. Occasionally MuLV gag and XMRV-LTR sequences were amplified from Indian prostate cancer samples, but were always detected in conjunction with contaminating murine genomic DNA. We found no evidence of XMRV or MuLV infection in the UK blood donors.

  11. Assessment of global and regional LV function obtained by quantitative gated SPECT using {sup 99m}Tc-tetrofosmin. Comparison with left ventricular cineangiography and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Kazunobu; Nakajima, Toru; Aoki, Naoto; Abe, Sumihisa; Handa, Shunnosuke; Suzuki, Yutaka [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine

    1998-11-01

    The quantitative gated SPECT (QGS) software that has automatic edge detection algorithm of the left ventricle, is able to calculate LV volumes and visualize LV wall motion with perfusion throughout the cardiac cycle. We evaluated the reliability of global and regional LV function derived from QGS using {sup 99m}Tc-tetrofosmin by comparing with left ventricular cineangiography (LVG) and echocardiography (ECHO). In 22 cardiac patients, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. Using cinematic display, regional LV wall motion were scored on a 3-point scale (1=normal, 2=hypokinesis, 3=akinesis; WMS). EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). Correlation between WMS derived from QGS and ECHO was high (r=0.85, p<0.001). There was an inverse correlation between WMS and LVEF (r=0.77, p<0.001). In conclusion, QGS is useful to evaluate global LV function. Regional wall motion evaluated by QGS is good enough for clinical application. (author)

  12. MoMuLV-ts-1: A Unique Mouse Model of Retrovirus-Induced Lymphoma Transmitted by Breast Milk

    Directory of Open Access Journals (Sweden)

    J. Chakraborty

    2011-01-01

    Full Text Available Our laboratory has developed a murine model of lymphoma via breast milk transmission of MoMuLV-ts-1 (Moloney murine leukemia virus-temperature sensitive mutant-1. Uninfected offspring suckled from infected surrogate mothers become infected and develop lymphoma. Multiple gene integration sites of ts-1 into the infected mouse genome including tacc3, aurka, ndel1, tpx2, p53, and rhamm were identified, and mRNA expressions were quantitated. These genes produce centrosomal proteins, which may be involved in abnormal chromosomal segregation leading to aneuploidy or multiploidy, thus causing lymphoma. Since there is no report to date on this retroviral model leading to centrosomal abnormality, and causing lymphoma development, this is a valuable and unique model to study the centrosomal involvement in lymphomagenesis.

  13. Effect of short-term rapid ventricular pacing followed by pacing interruption on arterial blood pressure in healthy pigs and pigs with tachycardiomyopathy.

    Science.gov (United States)

    Skrzypczak, P; Zyśko, D; Pasławska, U; Noszczyk-Nowak, A; Janiszewski, A; Gajek, J; Nicpoń, J; Kiczak, L; Bania, J; Zacharski, M; Tomaszek, A; Jankowska, E A; Ponikowski, P; Witkiewicz, W

    2014-01-01

    Ventricular tachycardia may lead to haemodynamic deterioration and, in the case of long term persistence, is associated with the development of tachycardiomyopathy. The effect of ventricular tachycardia on haemodynamics in individuals with tachycardiomyopathy, but being in sinus rhythm has not been studied. Rapid ventricular pacing is a model of ventricular tachycardia. The aim of this study was to determine the effect of rapid ventricular pacing on blood pressure in healthy animals and those with tachycardiomyopathy. A total of 66 animals were studied: 32 in the control group and 34 in the study group. The results of two groups of examinations were compared: the first performed in healthy animals (133 examinations) and the second performed in animals paced for at least one month (77 examinations). Blood pressure measurements were taken during chronic pacing--20 min after onset of general anaesthesia, in baseline conditions (20 min after pacing cessation or 20 min after onset of general anaesthesia in healthy animals) and immediately after short-term rapid pacing. In baseline conditions significantly higher systolic and diastolic blood pressure was found in healthy animals than in those with tachycardiomyopathy. During an event of rapid ventricular pacing, a significant decrease in systolic and diastolic blood pressure was found in both groups of animals. In the group of chronically paced animals the blood pressure was lower just after restarting ventricular pacing than during chronic pacing. Cardiovascular adaptation to ventricular tachycardia develops with the length of its duration. Relapse of ventricular tachycardia leads to a blood pressure decrease more pronounced than during chronic ventricular pacing.

  14. Chymase inhibition prevents fibronectin and myofibrillar loss and improves cardiomyocyte function and LV torsion angle in dogs with isolated mitral regurgitation.

    Science.gov (United States)

    Pat, Betty; Chen, Yuanwen; Killingsworth, Cheryl; Gladden, James D; Shi, Ke; Zheng, Junying; Powell, Pamela C; Walcott, Greg; Ahmed, Mustafa I; Gupta, Himanshu; Desai, Ravi; Wei, Chih-Chang; Hase, Naoki; Kobayashi, Tsunefumi; Sabri, Abdelkarim; Granzier, Henk; Denney, Thomas; Tillson, Michael; Dillon, A Ray; Husain, Ahsan; Dell'italia, Louis J

    2010-10-12

    The left ventricular (LV) dilatation of isolated mitral regurgitation (MR) is associated with an increase in chymase and a decrease in interstitial collagen and extracellular matrix. In addition to profibrotic effects, chymase has significant antifibrotic actions because it activates matrix metalloproteinases and kallikrein and degrades fibronectin. Thus, we hypothesize that chymase inhibitor (CI) will attenuate extracellular matrix loss and LV remodeling in MR. We studied dogs with 4 months of untreated MR (MR; n=9) or MR treated with CI (MR+CI; n=8). Cine MRI demonstrated a >40% increase in LV end-diastolic volume in both groups, consistent with a failure of CI to improve a 25% decrease in interstitial collagen in MR. However, LV cardiomyocyte fractional shortening was decreased in MR versus normal dogs (3.71±0.24% versus 4.81±0.31%; P<0.05) and normalized in MR+CI dogs (4.85±0.44%). MRI with tissue tagging demonstrated an increase in LV torsion angle in MR+CI versus MR dogs. CI normalized the significant decrease in fibronectin and FAK phosphorylation and prevented cardiomyocyte myofibrillar degeneration in MR dogs. In addition, total titin and its stiffer isoform were increased in the LV epicardium and paralleled the changes in fibronectin and FAK phosphorylation in MR+CI dogs. These results suggest that chymase disrupts cell surface-fibronectin connections and FAK phosphorylation that can adversely affect cardiomyocyte myofibrillar structure and function. The greater effect of CI on epicardial versus endocardial titin and noncollagen cell surface proteins may be responsible for the increase in torsion angle in chronic MR.

  15. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca2+-sensitive K+ current in miniature swine with LV hypertrophy

    Science.gov (United States)

    Tharp, Darla L.; Ivey, Jan R.; Ganjam, Venkataseshu K.; Bowles, Douglas K.

    2011-01-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ETA) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K+ currents (IK+) in coronary smooth muscle cells. Raising internal Ca2+ from 200 to 500 nM increased Ca2+-sensitive K+ current in HF-TR and control, but not HF animals. In conclusion, an ETA-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca2+-sensitive IK+ was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca2+-sensitive IK+, illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy. PMID:21841018

  16. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca²⁺-sensitive K⁺ current in miniature swine with LV hypertrophy.

    Science.gov (United States)

    Emter, Craig A; Tharp, Darla L; Ivey, Jan R; Ganjam, Venkataseshu K; Bowles, Douglas K

    2011-10-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ET(A)) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K(+) currents (I(K(+))) in coronary smooth muscle cells. Raising internal Ca(2+) from 200 to 500 nM increased Ca(2+)-sensitive K(+) current in HF-TR and control, but not HF animals. In conclusion, an ET(A)-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca(2+)-sensitive I(K(+)) was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca(2+)-sensitive I(K(+)), illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy.

  17. A prospective, randomized, double-blind, placebo-controlled parallel-group dual site trial to evaluate the effects of a Bacillus coagulans-based product on functional intestinal gas symptoms

    Directory of Open Access Journals (Sweden)

    Feldman Samantha

    2009-11-01

    Full Text Available Abstract Background This randomized double blind placebo controlled dual site clinical trial compared a probiotic dietary supplement to placebo regarding effects on gastrointestinal symptoms in adults with post-prandial intestinal gas-related symptoms (abdominal pain, distention, flatulence but no gastrointestinal (GI diagnoses to explain the symptoms. Methods Sixty-one adults were enrolled (age 36.5 ± 12.6 years; height 165.1 ± 9.2 cm; weight 75.4 ± 17.3 kg and randomized to either Digestive Advantage™ Gas Defense Formula - (GanedenBC30 Bacillus coagulans GBI-30, 6086: n = 30; or Placebo: n = 31. Study subjects were evaluated every two weeks over a four-week period using validated questionnaires and standard biochemical safety testing. Outcome criteria of interest included change from baseline in Gastrointestinal Symptom Rating Scale (GSRS abdominal pain, abdominal distention, flatus, and the Severity of Dyspepsia Assessment (SODA bloating and gas subscores over four weeks of product use. Results Measured against the placebo, subjects in the probiotic group achieved significant improvements in GSRS abdominal pain subscore (p = 0.046 and the GSRS total score (p = 0.048, with a strong trend for improvement on the GSRS abdominal distension subscore (p = 0.061. A strong placebo effect was evident which could explain the lack of statistical significant differences between the groups for many of the efficacy variables. Conclusion In conclusion, the Bacillus coagulans-based product was effective in improving the quality of life and reducing gastrointestinal symptoms in adults with post prandial intestinal gas-related symptoms and no GI diagnoses. Trial Registration ClinicalTrials.gov Identifier: NCT00881322

  18. A prospective, randomized, double-blind, placebo-controlled parallel-group dual site trial to evaluate the effects of a Bacillus coagulans-based product on functional intestinal gas symptoms

    Science.gov (United States)

    2009-01-01

    Background This randomized double blind placebo controlled dual site clinical trial compared a probiotic dietary supplement to placebo regarding effects on gastrointestinal symptoms in adults with post-prandial intestinal gas-related symptoms (abdominal pain, distention, flatulence) but no gastrointestinal (GI) diagnoses to explain the symptoms. Methods Sixty-one adults were enrolled (age 36.5 ± 12.6 years; height 165.1 ± 9.2 cm; weight 75.4 ± 17.3 kg) and randomized to either Digestive Advantage™ Gas Defense Formula - (GanedenBC30 Bacillus coagulans GBI-30, 6086): n = 30; or Placebo: n = 31. Study subjects were evaluated every two weeks over a four-week period using validated questionnaires and standard biochemical safety testing. Outcome criteria of interest included change from baseline in Gastrointestinal Symptom Rating Scale (GSRS) abdominal pain, abdominal distention, flatus, and the Severity of Dyspepsia Assessment (SODA) bloating and gas subscores over four weeks of product use. Results Measured against the placebo, subjects in the probiotic group achieved significant improvements in GSRS abdominal pain subscore (p = 0.046) and the GSRS total score (p = 0.048), with a strong trend for improvement on the GSRS abdominal distension subscore (p = 0.061). A strong placebo effect was evident which could explain the lack of statistical significant differences between the groups for many of the efficacy variables. Conclusion In conclusion, the Bacillus coagulans-based product was effective in improving the quality of life and reducing gastrointestinal symptoms in adults with post prandial intestinal gas-related symptoms and no GI diagnoses. Trial Registration ClinicalTrials.gov Identifier: NCT00881322 PMID:19922649

  19. A prospective, randomized, double-blind, placebo-controlled parallel-group dual site trial to evaluate the effects of a Bacillus coagulans-based product on functional intestinal gas symptoms.

    Science.gov (United States)

    Kalman, Douglas S; Schwartz, Howard I; Alvarez, Patricia; Feldman, Samantha; Pezzullo, John C; Krieger, Diane R

    2009-11-18

    This randomized double blind placebo controlled dual site clinical trial compared a probiotic dietary supplement to placebo regarding effects on gastrointestinal symptoms in adults with post-prandial intestinal gas-related symptoms (abdominal pain, distention, flatulence) but no gastrointestinal (GI) diagnoses to explain the symptoms. Sixty-one adults were enrolled (age 36.5 +/- 12.6 years; height 165.1 +/- 9.2 cm; weight 75.4 +/- 17.3 kg) and randomized to either Digestive Advantage Gas Defense Formula - (GanedenBC30 Bacillus coagulans GBI-30, 6086): n = 30; or Placebo: n = 31. Study subjects were evaluated every two weeks over a four-week period using validated questionnaires and standard biochemical safety testing. Outcome criteria of interest included change from baseline in Gastrointestinal Symptom Rating Scale (GSRS) abdominal pain, abdominal distention, flatus, and the Severity of Dyspepsia Assessment (SODA) bloating and gas subscores over four weeks of product use. Measured against the placebo, subjects in the probiotic group achieved significant improvements in GSRS abdominal pain subscore (p = 0.046) and the GSRS total score (p = 0.048), with a strong trend for improvement on the GSRS abdominal distension subscore (p = 0.061). A strong placebo effect was evident which could explain the lack of statistical significant differences between the groups for many of the efficacy variables. In conclusion, the Bacillus coagulans-based product was effective in improving the quality of life and reducing gastrointestinal symptoms in adults with post prandial intestinal gas-related symptoms and no GI diagnoses. ClinicalTrials.gov Identifier: NCT00881322.

  20. In hypertrophic cardiomyopathy reduction of relative resting myocardial blood flow is related to late enhancement, T2-signal and LV wall thickness.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available To quantify resting myocardial blood flow (MBF in the left ventricular (LV wall of HCM patients and to determine the relationship to important parameters of disease: LV wall thickness, late gadolinium enhancement (LGE, T2-signal abnormalities (dark and bright signal, LV outflow tract obstruction and age.Seventy patients with proven HCM underwent cardiac MRI. Absolute and relative resting MBF were calculated from cardiac perfusion MRI by using the Fermi function model. The relationship between relative MBF and LV wall thickness, T2-signal abnormalities (T2 dark and T2 bright signal, LGE, age and LV outflow gradient as determined by echocardiography was determined using simple and multiple linear regression analysis. Categories of reduced and elevated perfusion in relation to non- or mildly affected reference segments were defined, and T2-signal characteristics and extent as well as pattern of LGE were examined. Statistical testing included linear and logistic regression analysis, unpaired t-test, odds ratios, and Fisher's exact test.804 segments in 70 patients were included in the analysis. In a simple linear regression model LV wall thickness (p<0.001, extent of LGE (p<0.001, presence of edema, defined as focal T2 bright signal (p<0.001, T2 dark signal (p<0.001 and age (p = 0.032 correlated inversely with relative resting MBF. The LV outflow gradient did not show any effect on resting perfusion (p = 0.901. Multiple linear regression analysis revealed that LGE (p<0.001, edema (p = 0.026 and T2 dark signal (p = 0.019 were independent predictors of relative resting MBF. Segments with reduced resting perfusion demonstrated different LGE patterns compared to segments with elevated resting perfusion.In HCM resting MBF is significantly reduced depending on LV wall thickness, extent of LGE, focal T2 signal abnormalities and age. Furthermore, different patterns of perfusion in HCM patients have been defined, which may represent different stages of

  1. Successful pacing using a batteryless sunlight-powered pacemaker.

    Science.gov (United States)

    Haeberlin, Andreas; Zurbuchen, Adrian; Schaerer, Jakob; Wagner, Joerg; Walpen, Sébastien; Huber, Christoph; Haeberlin, Heinrich; Fuhrer, Juerg; Vogel, Rolf

    2014-10-01

    Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  2. Toward a More Efficient Implementation of Antifibrillation Pacing.

    Directory of Open Access Journals (Sweden)

    Dan Wilson

    Full Text Available We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing.

  3. Toward a More Efficient Implementation of Antifibrillation Pacing

    Science.gov (United States)

    Wilson, Dan; Moehlis, Jeff

    2016-01-01

    We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing. PMID:27391010

  4. Managing innovation: lessons from the cardiac-pacing industry.

    Science.gov (United States)

    Gobeli, D H; Rudelius, W

    1985-01-01

    In this article, the authors argue that innovation is a surefire way for a firm to increase its sales and market share. This, in turn, can stimulate American industries and make American firms more competitive in international markets. Through their study of the cardiac-pacing industry, they draw conclusions about what factors contribute to a successful innovation in other industries besides medical electronics. They identify general patterns and stages of the innovation process, key roles top management must fill in an organization, and effective policies that foster important innovations.

  5. Structural analysis of cell wall polysaccharides using PACE

    Energy Technology Data Exchange (ETDEWEB)

    Mortimer, Jennifer C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Joint BioEnergy Institute

    2017-01-01

    The plant cell wall is composed of many complex polysaccharides. The composition and structure of the polysaccharides affect various cell properties including cell shape, cell function and cell adhesion. Many techniques to characterize polysaccharide structure are complicated, requiring expensive equipment and specialized operators e.g. NMR, MALDI-MS. PACE (Polysaccharide Analysis using Carbohydrate gel Electrophoresis) uses a simple, rapid technique to analyze polysaccharide quantity and structure (Goubet et al. 2002). Whilst the method here describes xylan analysis, it can be applied (by use of the appropriate glycosyl hydrolase) to any cell wall polysaccharide.

  6. Setting the right path and pace for integration.

    Science.gov (United States)

    Cwiek, Katherine A; Inniger, Meredith C; Zismer, Daniel K

    2014-04-01

    Far from being a monolithic trend, integration in health care today is progressing in various forms, and at different rates in different markets within and across the range of healthcare organizations. Each organization should develop a tailored strategy that delineates the level and type of integration it will pursue and at what pace to pursue it. This effort will require evaluation of external market conditions with respect to integration and competition and a candid assessment of intraorganizational integration. The compared results of the two analyses will provide the basis for formulating strategy.

  7. Ecuador steps up pace of oil development activity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that oil companies operating in Ecuador plan to quicken the pace of oil development this year. After delays in 1991, companies plan a series of projects to develop reserves discovered the past 3 years estimated at more than 600 million bbl. Oil and Gas Journal estimated Ecuador's proved crude reserves at 1.55 billion bbl as of Jan. 1, 1992. The development push is part of a larger effort needed to ensure Ecuador's status as an oil exporter into the next century. Ecuador is the smallest crude oil producer and exporter in the Organization of Petroleum Exporting Countries

  8. The Influence of a Pacesetter on Psychological Responses and Pacing Behavior during a 1600 m Run

    Directory of Open Access Journals (Sweden)

    Christopher L. Fullerton, Andrew M. Lane, Tracey J. Devonport

    2017-12-01

    Full Text Available This study compared the effects of following a pacer versus following a self-paced plan on psychological responses and pacing behavior in well-trained distance runners. Pacing in the present study was individually tailored where each participant developed a personal strategy to ensure their goal time was achieved. We expected that following a pacer would associate with goal achievement, higher pre-run confidence, positive emotions and lower perceived exertion during performance. In a mixed-design repeated-measures study, nineteen well-trained runners completed two 1600m running time trials. Ten runners had a pacer (paced group who supported their individual pacing strategy, and nine participants self-paced running alone (control group. Both groups could check pace using their wrist watch. In contrast to our expectation, results indicated that the paced group reported higher pre-run anxiety with no significant differences in finish time, goal confidence, goal difficulty, perceived exertion, and self-rated performance between groups. We suggest that following a pacer is a skill that requires learning. Following a personalised pacer might associate with higher anxiety due to uncertainty in being able to keep up with the pacer and public visibility of dropping behind, something that is not so observable in a self-paced run completed alone. Future research should investigate mechanisms associated with effective pacing.

  9. Ischemic Stroke with Cardiac Pacemaker Implantation: Comparison of Physiological and Ventricular Pacing Modes.

    Science.gov (United States)

    Kato, Yuji; Hayashi, Takeshi; Kato, Ritsushi; Tanahashi, Norio; Takao, Masaki

    2017-09-01

    The clinical characteristics of ischemic stroke in patients with a pacemaker (PM) are not well understood. Forty-six ischemic stroke patients with a PM were investigated retrospectively, and the impact of different pacing modes was compared. The patients were divided into a physiological pacing group (n = 22) and a ventricular pacing group (n = 24). The prevalence of atrial fibrillation (AF) was significantly higher in the ventricular pacing group (36% versus 75%; P = .008). The mean left atrial dimension was relatively large in the ventricular pacing group than in the physiological pacing group (44.5 ± 6.7 mm versus 39.1 ± 8.5 mm, respectively; P = .071). Twenty-four percent of the patients were receiving anticoagulants, whereas 41% of the patients were receiving antiplatelet drugs. Cardioembolism was the most common stroke subtype in both groups. Although there was no statistically significant difference, neurological severity on admission was higher in the ventricular pacing group than in the physiological pacing group (P = .061). Functional outcomes, excluding patients with transient ischemic attack or prior stroke, significantly declined in the ventricular pacing group compared with the physiological pacing group (P = .044). The avoidance of the ventricular pacing mode may result in improved clinical outcomes. In patients without persistent AF, it may be important to select physiological pacing instead of ventricular pacing to decrease potential stroke severity. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. The influence of collective behaviour on pacing in endurance competitions

    Directory of Open Access Journals (Sweden)

    Andrew eRenfree

    2015-12-01

    Full Text Available A number of theoretical models have been proposed to explain pacing strategies in individual competitive endurance events. These have typically related to internal regulatory processes informing the making of decisions relating to muscular work rate. Despite a substantial body of research investigating the influence of collective group dynamics on individual behaviours in various animal species, this issue has not been comprehensively studied in individual athletic events. This is surprising given that athletes directly compete in close proximity to one another, and that collective behaviour has also been observed in other human environments. Whilst reasons for adopting collective behaviour are not fully understood, it is thought to result from individual agents following simple local rules resulting in seemingly complex large systems acting to confer some biological advantage to the collective as a whole. Although such collective behaviours may generally be beneficial, endurance events are complicated by the fact that increasing levels of physiological disruption as activity progresses may compromise the ability of individuals to continue to interact with other group members. This could result in early fatigue and relative underperformance due to suboptimal utilisation of physiological resources by some athletes. Alternatively, engagement with a collective behaviour may benefit all due to a reduction in the complexity of decisions to be made and a subsequent reduction in cognitive loading and mental fatigue. This paper seeks evidence for collective behaviour in previously published analyses of pacing behaviour and proposes mechanisms through which it could potentially be either beneficial, or detrimental to individual performance.

  11. Pilot trial of an age-paced parenting newsletter.

    Science.gov (United States)

    Keane, Brigid; Waterston, Tony; McConachie, Helen; Towner, Elizabeth; Cook, Margaret; Birks, Eileen

    2005-10-01

    Supporting parents in the first three years of a child's life has the potential to produce successful outcomes. Present government initiatives such as Sure Start focus on this age group. An American educational intervention, in the style of a monthly newsletter, was adapted for use in the UK for parents of young children. Topics were presented in an easy-to-read format and focused on infant emotional development, parent interaction and play. Newsletters, called Baby Express were posted at monthly intervals to the family home providing age-paced information which could meet the specific needs of parents at that stage of their child's life. The aim of the study was to determine the applicability of the newsletter to UK parents and evaluate their satisfaction. Sixty home-based interviews were conducted and 95 per cent of mothers reported reading all or part of the newsletter. Changes in parenting style were spontaneously reported by 28 per cent of mothers. This study found that an aged-paced parenting newsletter was an acceptable and useful method of supporting parents in the early months of a child's life and promotes positive changes in parenting behaviour.

  12. Social Interaction in Self-paced Distance Education

    Directory of Open Access Journals (Sweden)

    Terry Anderson

    2015-02-01

    Full Text Available In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions with other students and to share as little or as much personal information with each other as they wished. We describe the learning design for the intervention and present survey data of student and tutor perception of value and content analysis of the archived contributions. The results indicate that the intervention was positively received by tutors and by the majority (but not all students and that the archive created by the students’ contributions was adding value to the course. We conclude that the intervention was a modest, yet manageable example of a learning enhancement to a traditional cognitive-behavioral, course that has positive impact and potential with little negative impact on workload.

  13. The SolarPACES strategy for the solar thermal breakthrough

    Energy Technology Data Exchange (ETDEWEB)

    Burch, G.D. [U.S. Department of Energy, Washington, DC (United States)

    1997-12-31

    Our national solar thermal research programs and our combined efforts conducted through IEA/SolarPACES have brought about many breakthroughs in the development of solar thermal technology. We have components and systems that are much more efficient, much more reliable, and can be built much more cost-efficiently than just a few years ago. As our technology development proceeds, we undoubtedly will continue to make significant progress, breakthroughs in fact, in all these areas - progress that will bring us even closer to economic parity with more conventional forms of energy. And while this progress is absolutely necessary, the question is whether it will be enough to allow solar thermal to break into the mainstream of global energy supply. Our new IEA/SolarPACES strategy, crafted and approved over the course of the past year, has recognized the changes we must face and given us license to begin to make those changes. We must begin addressing financial hurdles, work to create a more favorable regulatory and tax environment, support development of international partnerships, and expand the visibility and excitement of solar thermal technology to achieve the final breakthroughs we need to allow solar thermal energy to live up to its vast potential. (orig./AKF)

  14. Leadless Cardiac Pacemakers: Current status of a modern approach in pacing

    Directory of Open Access Journals (Sweden)

    Skevos Sideris

    2017-11-01

    Full Text Available Since the first transvenous pacemaker implantation, which took place 50 years ago, important progress has been achieved in pacing technology. Consequently, at present, more than 700,000 pacemakers are implanted annually worldwide. However, conventional pacemakers' implantation has a non-negligible risk of periprocedural and long-term complications associated with the transvenous leads and pacemaker pocket. Recently, leadless pacing systems have emerged as a therapeutic alternative to conventional pacing systems that provide therapy for patients with bradyarrhythmias, while eliminating potential transvenous lead- and pacemaker pocket-related complications. Initial studies have demonstrated favorable efficacy and safety of currently developed leadless pacing systems, compared to transvenous pacemakers. In the present paper, we review the current evidence and highlight the advantages and disadvantages of this novel technology. New technological advances may allow the next generation of leadless pacemakers to further expand, thereby offering a wireless cardiac pacing in future. Keywords: cardiac pacing, pacemaker, leadless pacemaker, bradycardia

  15. Pacing a data transfer operation between compute nodes on a parallel computer

    Science.gov (United States)

    Blocksome, Michael A [Rochester, MN

    2011-09-13

    Methods, systems, and products are disclosed for pacing a data transfer between compute nodes on a parallel computer that include: transferring, by an origin compute node, a chunk of an application message to a target compute node; sending, by the origin compute node, a pacing request to a target direct memory access (`DMA`) engine on the target compute node using a remote get DMA operation; determining, by the origin compute node, whether a pacing response to the pacing request has been received from the target DMA engine; and transferring, by the origin compute node, a next chunk of the application message if the pacing response to the pacing request has been received from the target DMA engine.

  16. Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and design.

    Science.gov (United States)

    Quesada, Aurelio; Botto, Gianluca; Erdogan, Ali; Kozak, Milan; Lercher, Peter; Nielsen, Jens Cosedis; Piot, Olivier; Ricci, Renato; Weiss, Christian; Becker, Daniel; Wetzels, Gwenn; De Roy, Luc

    2008-03-01

    Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to conventional pacemaker and implantable cardioverter-defibrillator programming in terms of freedom from hospitalization for cardiovascular causes in a population of patients exposed to long periods of ventricular pacing. PreFER MVP is a prospective, 1:1 parallel, randomized (MVP ON/MVP OFF), single-blinded multi-centre trial. The study population consists of patients with more than 40% ventricular pacing documented with their previous device. Approximately, 600 patients will be randomized and followed for at least 24 months. The primary endpoint comprises cardiovascular hospitalization. The PreFER MVP trial is the first large prospective randomized clinical trial evaluating the effect of MVP in patients with a history of RV pacing.

  17. Comparison of pacing algorithms to avoid unnecessary ventricular pacing in patients with sick sinus node syndrome: a single-centre, observational, parallel study.

    Science.gov (United States)

    Poghosyan, Hermine R; Jamalyan, Smbat V

    2012-10-01

    Reduction of unnecessary ventricular pacing (uVP) is an essential component in the treatment strategy in any pacing population in general. The aim of this study was to evaluate the efficacy of different algorithms to reduce uVP in an adult population with sick sinus syndrome (SSS) treated outside of clinical trials. Evaluation of the relationship between different types of pacing algorithms and clinical outcomes is also provided. This was a single-centre, observational, parallel study, based on retrospective analysis of the Arrhythmology Cardiology Center of Armenia electronic clinical database. This study evaluated atrial pacing percentage (AP%), ventricular pacing percentage (VP%), and the incidence of atrial high rate episodes in 56 patients with SSS using three different pacing strategies: managed VP, search atrioventricular (AV), and fixed long AV. We did not find statistically significant differences in the amount of VP between the groups. Although the atrial high rate percentage (AHR%) tended to be higher in the fixed long AV group, this difference was not statistically significant. Mean VP% and AP% were similar in all three groups. In our study, all three programmed strategies produced the same mean AP% and VP%, and were equally efficient in uVP reduction. There was no relationship between chosen algorithms and the incidence of pacemaker syndrome, hospitalizations, or change in New York Heart Association class. The percentage of AHR was not associated with pacing strategy or co-morbidities but showed borderline correlation with left atrial size.

  18. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  19. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  20. The Effect of Phenazine-1-Carboxylic Acid on Mycelial Growth of Botrytis cinerea Produced by Pseudomonas aeruginosa LV Strain

    Directory of Open Access Journals (Sweden)

    Ane S. Simionato

    2017-06-01

    Full Text Available One of the most important postharvest plant pathogens that affect strawberries, grapes and tomatoes is Botrytis cinerea, known as gray mold. The fungus remains in latent form until spore germination conditions are good, making infection control difficult, causing great losses in the whole production chain. This study aimed to purify and identify phenazine-1-carboxylic acid (PCA produced by the Pseudomonas aeruginosa LV strain and to determine its antifungal activity against B. cinerea. The compounds produced were extracted with dichloromethane and passed through a chromatographic process. The purity level of PCA was determined by reversed-phase high-performance liquid chromatography semi-preparative. The structure of PCA was confirmed by nuclear magnetic resonance and electrospray ionization mass spectrometry. Antifungal activity was determined by the dry paper disk and minimum inhibitory concentration (MIC methods and identified by scanning electron microscopy and confocal microscopy. The results showed that PCA inhibited mycelial growth, where MIC was 25 μg mL-1. Microscopic analysis revealed a reduction in exopolysaccharide (EPS formation, showing distorted and damaged hyphae of B. cinerea. The results suggested that PCA has a high potential in the control of B. cinerea and inhibition of EPS (important virulence factor. This natural compound is a potential alternative to postharvest control of gray mold disease.

  1. Binding of Dumbbell Oligonucleotides to MoMuLV Reverse Transcriptase: Inhibitory Properties of RNase H Activity

    Directory of Open Access Journals (Sweden)

    Ajay Kumar

    2010-01-01

    Full Text Available Dumbbell oligonucleotides with loops of various chemistry were synthesized. Incubation of dumbbell oligonucleotides containing phosphorothioate bonds or trimethylene phosphate linkages in loops with S1 nuclease did not result in significant cleavage under conditions which led to the degradation of dumbbell oligonucleotide containing phophodiester bonds in the loops. The binding of reverse transcriptase of Moloney Murine Leukemia Virus (MoMuLV was evaluated with all the five oligonucleotides. The protein binds to all the dumbbell oligonucleotides with similar affinity. The dissociation constants evaluated using PAGE band mobility shift assays were of the order of 10-7. The inhibitory properties of the retroviral RNase H activity was evaluated using 3H –UTP-labeled RNA:RNA-DNA hybrid. It was found that the best dumbbell oligonucleotide, inhibitor contained phosphorothioate residues in both the loops. Our value studies demonstrated that this particularly designed oligonucleotide displays an IC50 of 18 nM in its inhibition on the reverse transcriptase RNase H activity, a magnitude lower than that of first nucleotide reverse transcriptase of HIV-1, tenofovir, introduced by Gilead Science in the market.

  2. A patient with severely reduced LV function and electrical storm saved by wearable cardioverter-defibrillator: a case report.

    Science.gov (United States)

    Strauss, Margit; Kouraki, Kleopatra; Skarlos, Alexandros; Zahn, Ralf; Kleemann, Thomas

    2013-06-01

    The wearable cardioverter-defibrillator (WCD) is indicated in patients who are considered to be at temporarily high risk for sudden cardiac death (SCD), when an implantable defibrillator is not yet clearly indicated. We report the case of a 41-year-old patient with a newly diagnosed severely reduced left ventricular (LV) function for suspected myocarditis and repeated nonsustained ventricular tachycardia (VT). This patient was supplied with a WCD who came back to the hospital 4 weeks after discharge with an electrical storm and adequate discharge of the WCD. After application of amiodarone, no further arrhythmias were detected during intrahospital course. For further risk stratification, we performed a magnetic field imaging (MFI), that was reported to be useful in risk assessment of SCD in patients with ischemic cardiomyopathy. This measurement showed a normal result, but we decided to give an implantable cardioverter-defibrillator (ICD) to the patient. During a follow-up of 1 year, no further arrhythmias occurred. With this case, we report the efficacy of a WCD, which is a novel tool in patients at temporarily high risk of SCD and we report a novel method of risk stratification in patients with a high risk of SCD.

  3. Analysis of Maneuvering Targets with Complex Motions by Two-Dimensional Product Modified Lv's Distribution for Quadratic Frequency Modulation Signals.

    Science.gov (United States)

    Jing, Fulong; Jiao, Shuhong; Hou, Changbo; Si, Weijian; Wang, Yu

    2017-06-21

    For targets with complex motion, such as ships fluctuating with oceanic waves and high maneuvering airplanes, azimuth echo signals can be modeled as multicomponent quadratic frequency modulation (QFM) signals after migration compensation and phase adjustment. For the QFM signal model, the chirp rate (CR) and the quadratic chirp rate (QCR) are two important physical quantities, which need to be estimated. For multicomponent QFM signals, the cross terms create a challenge for detection, which needs to be addressed. In this paper, by employing a novel multi-scale parametric symmetric self-correlation function (PSSF) and modified scaled Fourier transform (mSFT), an effective parameter estimation algorithm is proposed-referred to as the Two-Dimensional product modified Lv's distribution (2D-PMLVD)-for QFM signals. The 2D-PMLVD is simple and can be easily implemented by using fast Fourier transform (FFT) and complex multiplication. These measures are analyzed in the paper, including the principle, the cross term, anti-noise performance, and computational complexity. Compared to the other three representative methods, the 2D-PMLVD can achieve better anti-noise performance. The 2D-PMLVD, which is free of searching and has no identifiability problems, is more suitable for multicomponent situations. Through several simulations and analyses, the effectiveness of the proposed estimation algorithm is verified.

  4. Quantitative Differentiation of LV Myocardium with and without Layer-Specific Fibrosis Using MRI in Hypertrophic Cardiomyopathy and Layer-Specific Strain TTE Analysis.

    Science.gov (United States)

    Funabashi, Nobusada; Takaoka, Hiroyuki; Ozawa, Koya; Kamata, Tomoko; Uehara, Masae; Komuro, Issei; Kobayashi, Yoshio

    2018-05-30

    To achieve further risk stratification in hypertrophic cardiomyopathy (HCM) patients, we localized and quantified layer-specific LVM fibrosis on MRI in HCM patients using regional layer-specific peak longitudinal strain (PLS) and peak circumferential strain (PCS) in LV myocardium (LVM) on speckle tracking transthoracic echocardiography (TTE). A total of 18 HCM patients (14 males; 58 ± 17 years) underwent 1.5T-MRI and TTE. PLS and PCS in each layer of the LVM (endocardium, epicardium, and whole-layer myocardium) were calculated for 17 AHA-defined lesions. MRI assessment showed that fibrosis was classified as endocardial, epicardial, or whole-layer (= either or both of these). Regional PLS was smaller in fibrotic endocardial lesions than in non-fibrotic endocardial lesions (P = 0.004). To detect LV endocardial lesions with fibrosis, ROC curves of regional PLS revealed an area under the curve (AUC) of 0.609 and a best cut-off point of 13.5%, with sensitivity of 65.3% and specificity of 54.3%. Regional PLS was also smaller in fibrotic epicardial lesions than in non-fibrotic epicardial lesions (P layer myocardium analysis, PLS was smaller in fibrotic lesions than in non-fibrotic lesions (P layer LV lesions with fibrosis, ROC curves of regional PLS revealed an AUC of 0.674 and a best cut-off point of 12.5%, with sensitivity of 79.0% and specificity of 50.7%. There were no significant differences in PCS of LV myocardium (endocardium, epicardium, and whole-layer) between fibrotic and non-fibrotic lesions. Quantitative regional PLS but not PCS in LV endocardium, epicardium, and whole-layer myocardium provides useful non-invasive information for layer-specific localization of fibrosis in HCM patients.

  5. Neurogenesis in the olfactory bulb induced by paced mating in the female rat is opioid dependent.

    Directory of Open Access Journals (Sweden)

    Marianela Santoyo-Zedillo

    Full Text Available The possibility to control the rate of sexual stimulation that the female rat receives during a mating encounter (pacing increases the number of newborn neurons that reach the granular layer of the accessory olfactory bulb (AOB. If females mate repeatedly, the increase in the number of neurons is observed in other regions of the AOB and in the main olfactory bulb (MOB. It has also been shown that paced mating induces a reward state mediated by opioids. There is also evidence that opioids modulate neurogenesis. In the present study, we evaluated whether the opioid receptor antagonist naloxone (NX could reduce the increase in neurogenesis in the AOB induced by paced mating. Ovariectomized female rats were randomly divided in 5 different groups: 1 Control (not mated treated with saline, 2 control (not mated treated with naloxone, 3 females that mated without controlling the sexual interaction (no-pacing, 4 females injected with saline before pacing the sexual interaction and 5 females injected with NX before a paced mating session. We found, as previously described, that paced mating induced a higher number of new cells in the granular layer of the AOB. The administration of NX before paced mating, blocked the increase in the number of newborn cells and prevented these cells from differentiating into neurons. These data suggest that opioid peptides play a fundamental role in the neurogenesis induced by paced mating in female rats.

  6. Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

    Directory of Open Access Journals (Sweden)

    Janice Swampillai, MD

    2011-01-01

    Full Text Available Implantation of a transvenous endocardial pacing lead in the right ventricle is contra-indicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approach is minimally invasive, provides effective ventricular stimulation with low pacing threshold and stable lead position, and is a feasible option when transvenous right ventricular pacing is not possible.

  7. Selection of permanent pacing position of cardiac ventricle in patients with complete right bundle branch block

    International Nuclear Information System (INIS)

    Yang Minquan; Zhou Jun; Zhu Yan; Wang Jin; Rong Xin; Zhang Xiaoyi

    2005-01-01

    Objective: To find out the optimal pacing localization by comparing different pacing positions of the right ventricle in brady-cardiacarrhythmia patients with complete right bundle branch block. Methods: DDD type of double lumen permanent pacemaker was implanted in each of the 8 cases of sick sinus syndrome (SSS) and/or III degree atrioventricular block (III degree AVB) with complete right bundle branch block in normal heart function or class I. For each patient, four pacing positions in right ventricle were compared and the QRS pacing durations were recorded. The position with the shortest the QRS duration was chosen as the permanent pacing position. Heart function, chest X-rays and left ventricle ejection fraction (LVEF) were followed up after the operation. Results: In all the 8 cases, the posterior septum of the right ventricle were chosen as the permanent pacing position, with the shorter pacing QRS duration than that of pre-operation (P<0.05) and other pacing positions of the right ventricle. All parameters of this permanent pacing position were within the normal range. During the follow-up of 6-36 months, no abnormity was found in cardiac functions. Conclusion: In brady-cardiacarrhythmia patients with complete right bundle branch block, the implantation of permanent pacemaker should be at the junction region of inlet and outlet tracts, of the posterior septum of the right ventricle with ideal physiological function. (authors)

  8. Pacing and Self-regulation: Important Skills for Talent Development in Endurance Sports.

    Science.gov (United States)

    Elferink-Gemser, Marije T; Hettinga, Florentina J

    2017-07-01

    Pacing has been characterized as a multifaceted goal-directed process of decision making in which athletes need to decide how and when to invest their energy during the race, a process essential for optimal performance. Both physiological and psychological characteristics associated with adequate pacing and performance are known to develop with age. Consequently, the multifaceted skill of pacing might be under construction throughout adolescence, as well. Therefore, the authors propose that the complex skill of pacing is a potential important performance characteristic for talented youth athletes that needs to be developed throughout adolescence. To explore whether pacing is a marker for talent and how talented athletes develop this skill in middle-distance and endurance sports, they aim to bring together literature on pacing and literature on talent development and self-regulation of learning. Subsequently, by applying the cyclical process of self-regulation to pacing, they propose a practical model for the development of performance in endurance sports in youth athletes. Not only is self-regulation essential throughout the process of reaching the long-term goal of athletic excellence, but it also seems crucial for the development of pacing skills within a race and the development of a refined performance template based on previous experiences. Coaches and trainers are advised to incorporate pacing as a performance characteristic in their talent-development programs by stimulating their athletes to reflect, plan, monitor, and evaluate their races on a regular basis to build performance templates and, as such, improve their performance.

  9. Pacing in Olympic track races: competitive tactics versus best performance strategy.

    Science.gov (United States)

    Thiel, Christian; Foster, Carl; Banzer, Winfried; De Koning, Jos

    2012-01-01

    The purpose of this study was to describe pacing strategies in the 800 to 10,000-m Olympic finals. We asked 1) if Olympic finals differed from World Records, 2) how variable the pace was, 3) whether runners faced catastrophic events, and 4) for the winning strategy. Publically available data from the Beijing 2008 Olympic Games gathered by four transponder antennae under the 400-m track were analysed to extract descriptors of pacing strategies. Individual pacing patterns of 133 finalists were visualised using speed by distance plots. Six of eight plots differed from the patterns reported for World Records. The coefficient of running speed variation was 3.6-11.4%. In the long distance finals, runners varied their pace every 100 m by a mean 1.6-2.7%. Runners who were 'dropped' from the field achieved a stable running speed and displayed an endspurt. Top contenders used variable pacing strategies to separate themselves from the field. All races were decided during the final lap. Olympic track finalists employ pacing strategies which are different from World Record patterns. The observed micro- and macro-variations of pace may have implications for training programmes. Dropping off the pace of the leading group is an active step, and the result of interactive psychophysiological decision making.

  10. The Pace and Shape of Senescence in Angiosperms

    DEFF Research Database (Denmark)

    Baudisch, Annette; Salguero-Gómez, Roberto; Jones, Owen

    2013-01-01

    1. Demographic senescence, the decay in fertility and increase in the risk of mortality with age, is one of the most striking phenomena in ecology and evolution. Comparative studies of senescence patterns of plants are scarce, and consequently, little is known about senescence and its determinants...... (‘senescence’), decreases (‘negative senescence’) or remains constant over age (‘negligible senescence’). 3. We extract mortality trajectories from ComPADRe III, a data base that contains demographic information for several hundred plant species. We apply age-from-stage matrix decomposition methods to obtain...... age-specific trajectories from 290 angiosperm species of various growth forms distributed globally. From these trajectories, we survey pace and shape values and investigate how growth form and ecoregion influence these two aspects of mortality using a Bayesian regression analysis that accounts...

  11. Quick pace of property acquisitions requires two-stage evaluations

    International Nuclear Information System (INIS)

    Hollo, R.; Lockwood, S.

    1994-01-01

    The traditional method of evaluating oil and gas reserves may be too cumbersome for the quick pace of oil and gas property acquisition. An acquisition evaluator must decide quickly if a property meets basic purchase criteria. The current business climate requires a two-stage approach. First, the evaluator makes a quick assessment of the property and submits a bid. If the bid is accepted then the evaluator goes on with a detailed analysis, which represents the second stage. Acquisition of producing properties has become an important activity for many independent oil and gas producers, who must be able to evaluate reserves quickly enough to make effective business decisions yet accurately enough to avoid costly mistakes. Independent thus must be familiar with how transactions usually progress as well as with the basic methods of property evaluation. The paper discusses acquisition activity, the initial offer, the final offer, property evaluation, and fair market value

  12. The pace of shifting climate in marine and terrestrial ecosystems

    DEFF Research Database (Denmark)

    Burrows, Michael T.; Schoeman, David S.; Buckley, Lauren B.

    2011-01-01

    Climate change challenges organisms to adapt or move to track changes in environments in space and time. We used two measures of thermal shifts from analyses of global temperatures over the past 50 years to describe the pace of climate change that species should track: the velocity of climate...... change (geographic shifts of isotherms over time) and the shift in seasonal timing of temperatures. Both measures are higher in the ocean than on land at some latitudes, despite slower ocean warming. These indices give a complex mosaic of predicted range shifts and phenology changes that deviate from...... simple poleward migration and earlier springs or later falls. They also emphasize potential conservation concerns, because areas of high marine biodiversity often have greater velocities of climate change and seasonal shifts....

  13. The heart and cardiac pacing in Steinert disease.

    Science.gov (United States)

    Nigro, Gerardo; Papa, Andrea Antonio; Politano, Luisa

    2012-10-01

    Myotonic dystrophy (Dystrophia Myotonica, DM) is the most frequently inherited neuromuscular disease of adult life. It is a multisystemic disease with major cardiac involvement. Core features of myotonic dystrophy are myotonia, muscle weakness, cataract, respiratory failure and cardiac conduction abnormalities. Classical DM, first described by Steinert and called Steinert's disease or DM1 (Dystrophia Myotonica type 1) has been identified as an autosomal dominant disorder associated with the presence of an abnormal expansion of a CTG trinucleotide repeat in the 3' untranslated region of DMPK gene on chromosome 19. This review will mainly focus on the various aspects of cardiac involvement in DM1 patients and the current role of cardiac pacing in their treatment.

  14. Pacing and Defibrillators in Complex Congenital Heart Disease

    Science.gov (United States)

    Chubb, Henry; O’Neill, Mark; Rosenthal, Eric

    2016-01-01

    Device therapy in the complex congenital heart disease (CHD) population is a challenging field. There is a myriad of devices available, but none designed specifically for the CHD patient group, and a scarcity of prospective studies to guide best practice. Baseline cardiac anatomy, prior surgical and interventional procedures, existing tachyarrhythmias and the requirement for future intervention all play a substantial role in decision making. For both pacing systems and implantable cardioverter defibrillators, numerous factors impact on the merits of system location (endovascular versus non-endovascular), lead positioning, device selection and device programming. For those with Fontan circulation and following the atrial switch procedure there are also very specific considerations regarding access and potential complications. This review discusses the published guidelines, device indications and the best available evidence for guidance of device implantation in the complex CHD population. PMID:27403295

  15. Influence of internal current and pacing current on pacemaker longevity.

    Science.gov (United States)

    Schuchert, A; Kuck, K H

    1994-01-01

    The effects of lower pulse amplitude on battery current and pacemaker longevity were studied comparing the new, small-sized VVI pacemaker, Minix 8341, with the former model, Pasys 8329. Battery current was telemetrically measured at 0.8, 1.6, 2.5, and 5.0 V pulse amplitude and 0.05, 0.25, 0.5, and 1.0 msec pulse duration. Internal current was assumed to be equal to the battery current at 0.8 V and 0.05 msec. Pacing current was calculated subtracting internal current from battery current. The Minix pacemaker had a significantly lower battery current because of a lower internal current (Minix: 4.1 +/- 0.1 microA; Pasys: 16.1 +/- 0.1 microA); pacing current of both units was similar. At 0.5 msec pulse duration, the programming from 5.0-2.5 V pulse amplitude resulted in a greater relative reduction of battery current in the newer pacemaker (51% vs 25%). Projected longevity of each pacemaker was 7.9 years at 5.0 V and 0.5 msec. The programming from 5.0-2.5 V extended the projected longevity by 2.3 years (Pasys) and by 7.1 years (Minix). The longevity was negligibly longer after programming to 1.6 V. extension of pacemaker longevity can be achieved with the programming to 2.5 V or less if the connected pacemakers need a low internal current for their circuitry.

  16. Astakine LvAST binds to the β subunit of F1-ATP synthase and likely plays a role in white shrimp Litopeneaus vannamei defense against white spot syndrome virus.

    Science.gov (United States)

    Liang, Gao-Feng; Liang, Yan; Xue, Qinggang; Lu, Jin-Feng; Cheng, Jun-Jun; Huang, Jie

    2015-03-01

    Cytokines play a critical role in innate and adaptive immunity. Astakines represent a group of invertebrate cytokines that are related to vertebrate prokineticin and function in promoting hematopoiesis in crustaceans. We have identified an astakine from the white shrimp Litopeneaus vannamei and named it LvAST in a previous research. In the present research, we investigated the interactions among LvAST, the envelope protein VP37 of white spot syndrome virus (i.e., WSSV), and the β subunit of F1-ATP synthase (ATPsyn-β) of the white shrimp (i.e., BP53) using binding assays and co-precipitations. We also examined the effects of LvAST on shrimp susceptibility to WSSV. We found that LvAST and VP37 competitively bound to BP53, but did not bind to each other. Shrimps that had been injected with recombinant LvAST exhibited significantly lower mortality and longer survival time in experimental infections by WSSV. In contrast, shrimps whose LvAST gene expression had been inhibited by RNA interference showed significantly higher WSSV infection intensity and shorter survival time following viral challenges. These results suggested that LvAST and WSSV both likely use ATPsyn-β as a receptor and LvAST plays a role in shrimp defense against WSSV infection. This represented the first research showing the involvement of astakines in host antiviral immunity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. How Pacing of Multimedia Instructions Can Influence Modality Effects: A Case of Superiority of Visual Texts

    Science.gov (United States)

    Stiller, Klaus D.; Freitag, Annika; Zinnbauer, Peter; Freitag, Christian

    2009-01-01

    "Present text accompanying pictures aurally to promote learning" is a well established principle of instructional design. But recently, it was shown that under certain conditions visual texts can be preferable. Instructional pacing seems to be one of these conditions that mediate effects. Especially, enabling learners to pace an…

  18. Racing an Opponent Alters Pacing, Performance and Muscle Force Decline, But Not RPE

    NARCIS (Netherlands)

    Konings, Marco J; Parkinson, Jordan; Zijdewind, Inge; Hettinga, Florentina

    PURPOSE: Performing against a virtual opponent has been shown to invite a change in pacing and improve time trial (TT) performance. This study explored how this performance improvement is established by assessing changes in pacing, neuromuscular function and perceived exertion. METHODS: After a peak

  19. Differential effects of film on preschool children's behaviour dependent on editing pace.

    Science.gov (United States)

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Levodopa reinstates connectivity from prefrontal to premotor cortex during externally paced movement in Parkinson's disease

    DEFF Research Database (Denmark)

    Herz, Damian M; Siebner, Hartwig R; Hulme, Oliver J

    2014-01-01

    , which were externally paced at a rate of 0.5Hz. This required participants to align their movement velocity to the slow external pace. Patients were studied after at least 12-hour withdrawal of dopaminergic medication (OFF state) and after intake of the dopamine precursor levodopa (ON state) in order...

  1. Child and Parental Outcomes Following Involvement in a Preventive Intervention: Efficacy of the PACE Program

    Science.gov (United States)

    Begle, Angela Moreland; Dumas, Jean E.

    2011-01-01

    This study evaluated whether engagement (i.e., attendance and quality of participation) in the Parenting our Children to Excellence (PACE) program predicted positive child and parent outcomes. PACE in an 8-week preventive intervention aimed at parents of preschool children. The study investigated the relation of engagement to outcomes in an…

  2. Challenge of Engaging All Students via Self-Paced Interactive Electronic Learning Tutorials for Introductory Physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-01-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar…

  3. Financing the Business. PACE Revised. Level 1. Unit 8. Research & Development Series No. 240AB8.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on financing a business, the eighth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  4. Keeping Pace with K-12 Online & Blended Learning: An Annual Review of Policy and Practice, 2013

    Science.gov (United States)

    Watson, John; Murin, Amy; Vashaw, Lauren; Gemin, Butch; Rapp, Chris

    2013-01-01

    This is the 10th annual "Keeping Pace" report. "Keeping Pace" has several goals: (1) add to the body of knowledge about online education policy and practice, and make recommendations for advances; (2) serve as a reference source for information about programs and policies across the country, both for policymakers and…

  5. The corticospinal responses of metronome-paced, but not self-paced strength training are similar to motor skill training.

    Science.gov (United States)

    Leung, Michael; Rantalainen, Timo; Teo, Wei-Peng; Kidgell, Dawson

    2017-12-01

    The corticospinal responses to skill training may be different to strength training, depending on how the strength training is performed. It was hypothesised that the corticospinal responses would not be different following skill training and metronome-paced strength training (MPST), but would differ when compared with self-paced strength training (SPST). Corticospinal excitability, short-interval intra-cortical inhibition (SICI) and strength and tracking error were measured at baseline and 2 and 4 weeks. Participants (n = 44) were randomly allocated to visuomotor tracking, MPST, SPST or a control group. MPST increased strength by 7 and 18%, whilst SPST increased strength by 12 and 26% following 2 and 4 weeks of strength training. There were no changes in strength following skill training. Skill training reduced tracking error by 47 and 58% at 2 and 4 weeks. There were no changes in tracking error following SPST; however, tracking error reduced by 24% following 4 weeks of MPST. Corticospinal excitability increased by 40% following MPST and by 29% following skill training. There was no change in corticospinal excitability following 4 weeks of SPST. Importantly, the magnitude of change between skill training and MPST was not different. SICI decreased by 41 and 61% following 2 and 4 weeks of MPST, whilst SICI decreased by 41 and 33% following 2 and 4 weeks of skill training. Again, SPST had no effect on SICI at 2 and 4 weeks. There was no difference in the magnitude of SICI reduction between skill training and MPST. This study adds new knowledge regarding the corticospinal responses to skill and MPST, showing they are similar but different when compared with SPST.

  6. METODE FUTURE PACING HYPNOTHERAPY UNTUK MENURUNKAN TINGKAT KECEMASAN PADA MAHASISWA BARU

    Directory of Open Access Journals (Sweden)

    Zahro Varisna Rohmadani

    2017-09-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui efektivitas metode future pacing hypnotherapy dalam menurunkan tingkat kecemasan pada mahasiswa baru. Subjek penelitian adalah 20 mahasiswa/i baru, 10 mahasiswa di kelompok eksperimen dan 10 mahasiswa di kelompok kontrol. Peserta mendapatkan penanganan untuk penurunan kecemasan dengan metode berupa future pacing hypnotherapy. Metode analisis data yang digunakan adalah statistik nonparametrik teknik Wilcoxon Signed Rank Test untuk menguji perbedaan skor cemas kelompok subjek saat pretest dan posttest serta Mann Whitney U untuk melihat perbedaan penurunan kecemasan pada kelompok eksperimen dan kelompok kontrol. Hasil Wilcoxon Signed Rank Test menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,012. Sedangkan hasil Mann Whitney U menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,003 dan kelompok eksperimen mengalami penurunan kecemasan yang lebih besar dengan mean rank = 14,25.Kata kunci : future pacing hypnotherapy, kecemasan, mahasiswa baru

  7. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study.

    Science.gov (United States)

    Kantharia, Bharat K; Freedman, Roger A; Hoekenga, David; Tomassoni, Gery; Worley, Seth; Sorrentino, Robert; Steinhaus, David; Wolkowicz, Joel M; Syed, Zaffer A

    2007-11-01

    Different pacing sites and various algorithms have been utilized to prevent atrial fibrillation (AF) in pacemaker recipients. However, the optimal pacing rate settings have not yet been established. In this randomized, prospective, multicentre, single-blinded, cross over study, rate-adaptive pacing at a high base rate (BR) in patients, age 60 years or above, or a history of paroxysmal AF, who underwent dual-chamber (DDD) pacemaker implantation for standard pacing indications, was evaluated for prevention of AF. In the study cohort of 145 patients implanted with DDD pacemakers with a programmable rest rate (RR) feature, the BR/RR settings were sequentially but randomly adjusted as follows: 60 bpm/Off for the baseline quarter (initial 3 months) and then to either 'A-B-C' or 'C-B-A' settings (A = 70/65 bpm, B = 70/Off, C = 80/65 bpm) for the subsequent quarters each of 3 months duration. Data on automatic mode switch episodes, device diagnostics, and a questionnaire evaluating pacemaker awareness and palpitations were collected. Ninety-nine patients, mean age 77 +/- 10 years, who completed the study protocol and followed for 12 months did not show significant differences in the number of mode switch episodes between any settings used. The percentage of atrial pacing was lower during baseline pacing compared to settings A, B, and C (P < 0.0001). Setting C produced a higher percentage of atrial pacing than A and B (P < 0.01). Although a higher percentage of atrial pacing correlated with a lower incidence of mode switch episodes, there was no statistically significant difference in the number of mode switch episodes between settings A, B, and C. There were no significant differences in the questionnaire scores relating to pacemaker awareness or palpitation. Overdrive single-site pacing in the right atrium achieved by programming analysed settings in the present study did not reduce AF as assessed by mode switch episodes. Additionally, no change in the symptoms of

  8. Establishment of a novel feline leukemia virus (FeLV)-negative B-cell cell line from a cat with B-cell lymphoma.

    Science.gov (United States)

    Mochizuki, Hiroyuki; Takahashi, Masashi; Nishigaki, Kazuo; Ide, Tetsuya; Goto-Koshino, Yuko; Watanabe, Shinya; Sato, Hirofumi; Sato, Masahiko; Kotera, Yukiko; Fujino, Yasuhito; Ohno, Koichi; Uchida, Kazuyuki; Tsujimoto, Hajime

    2011-04-15

    We established a novel feline B-cell line, MS4, from the neoplastic pleural effusion of a cat with cutaneous B-cell lymphoma. Immunophenotype staining of the MS4 cells was positive for CD20, CD79α, and IgA and negative for CD3, CD4, CD5, CD8α, CD18, CD21, CD22, IgM, IgG, Ig light chain, and MHC class II. PCR analysis for immunoglobulin heavy chain gene rearrangements revealed a monoclonal rearrangement, whereas no clonal rearrangement of the T-cell receptor γ gene was detected. Southern blotting with an exogenous feline leukemia virus (FeLV) U3 probe revealed no integration of exogenous FeLV provirus. The MS4 cell line is the first FeLV-negative feline B-cell lymphoma cell line, and may be used to investigate the pathogenesis of spontaneously occurring feline lymphoma and the development of new therapies. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  10. Mechanical Alterations during 800-m Self-Paced Track Running.

    Science.gov (United States)

    Girard, Olivier; Millet, Gregoire P; Micallef, Jean-Paul

    2017-04-01

    We assessed the time course of running mechanical alterations during an 800-m. On a 200-m indoor track, 18 physical education students performed an 800-m self-paced run. Once per lap, ground reaction forces were measured by a 5-m-long force platform system, and used to determine running kinetics/kinematics and spring-mass characteristics. Compared with 100 m (19.4±1.8 km.h -1 ) running velocity progressively decreased at 300, 500 m but levelled-off at 700 m marks (-5.7±4.6, -10.4±8.3, and -9.1±13.5%, respectively; Ppush-off forces (-5.1±7.2%, P0.05) and leg compression (+2.8±3.9%; P>0.05) remained unchanged, whereas centre of mass vertical displacement (+24.0±7.0%; P0.05). During an 800 m by physical education students, highest running velocity was achieved early during the run, with a progressive decrease in the second half of the trial. While vertical ground force characteristics remained unchanged, non-specialist runners produced lower peak braking and push-off forces, in turn leading to shorter stride length. Spring-mass model characteristics changed toward lower vertical stiffness values, whereas leg stiffness did not change. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Diaphragm pacing improves sleep in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Gonzalez-Bermejo, Jesus; Morélot-Panzini, Capucine; Salachas, François; Redolfi, Stefania; Straus, Christian; Becquemin, Marie-Hélène; Arnulf, Isabelle; Pradat, Pierre-François; Bruneteau, Gaëlle; Ignagni, Anthony R; Diop, Moustapha; Onders, Raymond; Nelson, Teresa; Menegaux, Fabrice; Meininger, Vincent; Similowski, Thomas

    2012-01-01

    In amyotrophic lateral sclerosis (ALS) patients, respiratory insufficiency is a major burden. Diaphragm conditioning by electrical stimulation could interfere with lung function decline by promoting the development of type 1 muscle fibres. We describe an ancillary study to a prospective, non-randomized trial (NCT00420719) assessing the effects of diaphragm pacing on forced vital capacity (FVC). Sleep-related disturbances being early clues to diaphragmatic dysfunction, we postulated that they would provide a sensitive marker. Stimulators were implanted laparoscopically in the diaphragm close to the phrenic motor point in 18 ALS patients for daily conditioning. ALS functioning score (ALSFRS), FVC, sniff nasal inspiratory pressure (SNIP), and polysomnographic recordings (PSG, performed with the stimulator turned off) were assessed before implantation and after four months of conditioning (n = 14). Sleep efficiency improved (69 ± 15% to 75 ± 11%, p = 0.0394) with fewer arousals and micro-arousals. This occurred against a background of deterioration as ALSFRS-R, FVC, and SNIP declined. There was, however, no change in NIV status or the ALSFRS respiratory subscore, and the FVC decline was mostly due to impaired expiration. Supporting a better diaphragm function, apnoeas and hypopnoeas during REM sleep decreased. In conclusion, in these severe patients not expected to experience spontaneous improvements, diaphragm conditioning improved sleep and there were hints at diaphragm function changes.

  12. Echocardiographic estimation of acute haemodynamic response during optimization of multisite pace-maker using different pacing modalities and atrioventricular delays

    Directory of Open Access Journals (Sweden)

    Šalinger-Martinović Sonja

    2009-01-01

    Full Text Available Background/Aim. Cardiac resynchronization therapy (CRT improves ventricular dyssynchrony and is associated with an improvement in symptoms, quality of life and prognosis in patients with severe heart failure and intraventricular conduction delay. Different pacing modalities produce variable activation patterns and may be a cause of different haemodynamic changes. The aim of our study was to investigate acute haemodynamic changes with different CRT configurations during optimization procedure. Methods. This study included 30 patients with severe left ventricular systolic dysfunction and left bundle branch block with wide QRS (EF 24.33 ± 3.7%, QRS 159 ± 17.3 ms, New York Heart Association III/IV 25/5 with implanted CRT device. The whole group of patients had severe mitral regurgitation in order to measure dP/dt. After implantation and before discharge all the patients underwent optimization procedure guided by Doppler echocardiography. Left and right ventricular pre-ejection intervals (LVPEI and RVPEI, interventricular mechanical delay (IVD and the maximal rate of ventricular pressure rise during early systole (max dP/dt were measured during left and biventricular pacing with three different atrioventricular (AV delays. Results. After CRT device optimization, optimal AV delay and CRT mode were defined. Left ventricular pre-ejection intervals changed from 170.5 ± 24.6 to 145.9 ± 9.5 (p < 0.001, RVPEI from 102.4 ± 15.9 to 119.8 ± 10.9 (p < 0.001, IVD from 68.1 ± 18.3 to 26.5 ± 8.2 (p < 0.001 and dP/dt from 524.2 ± 67 to 678.2 ± 88.5 (p < 0.01. Conclusion. In patients receiving CRT echocardiographic assessment of the acute haemodynamic response to CRT is a useful tool in optimization procedure. The variability of Doppler parameters with different CRT modalities emphasizes the necessity of individualized approach in optimization procedure.

  13. Kinematic hand parameters in front crawl at different paces of swimming.

    Science.gov (United States)

    Samson, Mathias; Monnet, Tony; Bernard, Anthony; Lacouture, Patrick; David, Laurent

    2015-11-05

    The aim of this study was to investigate the evolution of kinematic hand parameters (sweepback angle, angle of attack, velocity, acceleration and orientation of the hand relative to the absolute coordinate system) throughout an aquatic stroke and to study the possible modifications caused by a variation of the swimming pace. Seventeen competitive swimmers swam at long distance, middle distance and sprint paces. Parameters were calculated from the trajectory of seven markers on the hand measured with an optoelectronic system. Results showed that kinematic hand parameters evolve differently depending on the pace. Angle of attack, sweepback angle, acceleration and orientation of the hand do not vary significantly. The velocity of the hand increases when the pace increases, but only during the less propulsive phases (entry and stretch and downsweep to catch). The more the pace increases and the more the absolute durations of the entry and stretch and downsweep to catch phases decrease. Absolute durations of the insweep and upsweep phases remain constant. During these phases, the propulsive hand forces calculated do not vary significantly when the pace increases. The increase of swimming pace is then explained by the swimmer's capacity to maintain propulsive phases rather than increasing the force generation within each cycle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Cardiac optogenetic pacing in drosophila melanogaster using red-shifted opsins (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Electrical pacing is the current gold standard for investigation of mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, this method requires an invasive surgical procedure to implant the pacing electrodes. Recently, optogenetic pacing has been developed as an alternative, non-invasive method for heartbeat pacing in animals. It induces heartbeats by shining pulsed light on transgene-generated microbial opsins which in turn activate light gated ion channels in animal hearts. However, commonly used opsins, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we expressed recently engineered red-shifted opsins, ReaChR and CsChrimson, in the heart of a well-developed animal model, Drosophila melanogaster, for the first time. Optogenetic pacing was successfully conducted in both ReaChR and CsChrimson flies at their larval, pupal, and adult stages using 617 nm excitation light pulse, enabling a much deeper tissue penetration compared to blue stimulation light. A customized high speed and ultrahigh resolution OCM system was used to non-invasively monitor the heartbeat pacing in Drosophila. Compared to previous studies on optogenetic pacing of Drosophila, higher penetration depth of optogenetic excitation light was achieved in opaque late pupal flies. Lower stimulating power density is needed for excitation at each developmental stage of both groups, which improves the safety of this technique for heart rhythm studies.

  15. Will the Conscious-Subconscious Pacing Quagmire Help Elucidate the Mechanisms of Self-Paced Exercise? New Opportunities in Dual Process Theory and Process Tracing Methods.

    Science.gov (United States)

    Micklewright, Dominic; Kegerreis, Sue; Raglin, John; Hettinga, Florentina

    2017-07-01

    The extent to which athletic pacing decisions are made consciously or subconsciously is a prevailing issue. In this article we discuss why the one-dimensional conscious-subconscious debate that has reigned in the pacing literature has suppressed our understanding of the multidimensional processes that occur in pacing decisions. How do we make our decisions in real-life competitive situations? What information do we use and how do we respond to opponents? These are questions that need to be explored and better understood, using smartly designed experiments. The paper provides clarity about key conscious, preconscious, subconscious and unconscious concepts, terms that have previously been used in conflicting and confusing ways. The potential of dual process theory in articulating multidimensional aspects of intuitive and deliberative decision-making processes is discussed in the context of athletic pacing along with associated process-tracing research methods. In attempting to refine pacing models and improve training strategies and psychological skills for athletes, the dual-process framework could be used to gain a clearer understanding of (1) the situational conditions for which either intuitive or deliberative decisions are optimal; (2) how intuitive and deliberative decisions are biased by things such as perception, emotion and experience; and (3) the underlying cognitive mechanisms such as memory, attention allocation, problem solving and hypothetical thought.

  16. A Closer Look at Split Visual Attention in System- and Self-Paced Instruction in Multimedia Learning

    Science.gov (United States)

    Schmidt-Weigand, Florian; Kohnert, Alfred; Glowalla, Ulrich

    2010-01-01

    Two experiments examined visual attention distribution in learning from text and pictures. Participants watched a 16-step multimedia instruction on the formation of lightning. In Experiment 1 (N=90) the instruction was system-paced (fast, medium, slow pace), while it was self-paced in Experiment 2 (N=31). In both experiments the text modality was…

  17. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of

  18. Whole-genome sequence of Erysipelothrix larvae LV19(T) (=KCTC 33523(T)), a useful strain for arsenic detoxification, from the larval gut of the rhinoceros beetle, Trypoxylus dichotomus.

    Science.gov (United States)

    Lim, Sooyeon; Rhee, Moon-Soo; Chang, Dong-Ho; Kim, Byoung-Chan

    2016-04-10

    Erysipelothrix larvae LV19(T) was preliminary isolated from the larval gut of a rhinoceros beetle, Trypoxylus dichotomus in Korea. Here, we present the whole genome sequence of E. larvae LV19(T) strain, which consisted of 2,511,486 base pairs with a GC content of 37.4% and one plasmid. Unlike other Erysipelothrix strains (SY 1027, Fujisawa and ATCC 19414), the arsenic-resistance genes were identified in LV19(T) strain. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. An Investigation on Exhaustion of SAP ERP Users: Influence of Pace of Change and Technostress

    Directory of Open Access Journals (Sweden)

    Prashanta Kumar Roy

    2017-10-01

    Full Text Available Despite recent growing research interest on ERP research, the understanding on ERP induced exhaustion is still limited. This study examines how the pace of change of ERP functionalities and interface causes exhaustion in workplace. For this purpose, we conducted an investigation on 128 ERP users from two different organizations in Bangladesh. We extended theory of technostress by integrating pace of change of ERP system. Result suggests that pace of change on ERP system significantly affect work-overload, work-life conflict and role ambiguity on ERP users. Result also shows that work-overload and role ambiguity are strong predictors for ERP induced exhaustion.

  20. Earlier Right Ventricular Pacing in Cardiac Resynchronization Therapy for a Patient with Right Axis Deviation.

    Science.gov (United States)

    Hattori, Yusuke; Ishibashi, Kohei; Noda, Takashi; Okamura, Hideo; Kanzaki, Hideaki; Anzai, Toshihisa; Yasuda, Satoshi; Kusano, Kengo

    2017-09-01

    We describe the case of a 37-year-old woman who presented with complete right bundle branch block and right axis deviation. She was admitted to our hospital due to severe heart failure and was dependent on inotropic agents. Cardiac resynchronization therapy was initiated but did not improve her condition. After the optimization of the pacing timing, we performed earlier right ventricular pacing, which led to an improvement of her heart failure. Earlier right ventricular pacing should be considered in patients with complete right bundle branch block and right axis deviation when cardiac resynchronization therapy is not effective.

  1. Sawtooth Pacing by Real-Time Auxiliary Power Control in a Tokamak Plasma

    International Nuclear Information System (INIS)

    Goodman, T. P.; Felici, F.; Sauter, O.; Graves, J. P.

    2011-01-01

    In the standard scenario of tokamak plasma operation, sawtooth crashes are the main perturbations that can trigger performance-degrading, and potentially disruption-generating, neoclassical tearing modes. This Letter demonstrates sawtooth pacing by real-time control of the auxiliary power. It is shown that the sawtooth crash takes place in a reproducible manner shortly after the removal of that power, and this can be used to precisely prescribe, i.e., pace, the individual sawteeth. In combination with preemptive stabilization of the neoclassical tearing modes, sawtooth pacing provides a new sawtooth control paradigm for improved performance in burning plasmas.

  2. Impact of operator experience and training strategy on procedural outcomes with leadless pacing: Insights from the Micra Transcatheter Pacing Study.

    Science.gov (United States)

    El-Chami, Mikhael; Kowal, Robert C; Soejima, Kyoko; Ritter, Philippe; Duray, Gabor Z; Neuzil, Petr; Mont, Lluis; Kypta, Alexander; Sagi, Venkata; Hudnall, John Harrison; Stromberg, Kurt; Reynolds, Dwight

    2017-07-01

    Leadless pacemaker systems have been designed to avoid the need for a pocket and transvenous lead. However, delivery of this therapy requires a new catheter-based procedure. This study evaluates the role of operator experience and different training strategies on procedural outcomes. A total of 726 patients underwent implant attempt with the Micra transcatheter pacing system (TPS; Medtronic, Minneapolis, MN, USA) by 94 operators trained in a teaching laboratory using a simulator, cadaver, and large animal models (lab training) or locally at the hospital with simulator/demo model and proctorship (hospital training). Procedure success, procedure duration, fluoroscopy time, and safety outcomes were compared between training methods and experience (implant case number). The Micra TPS procedure was successful in 99.2% of attempts and did not differ between the 55 operators trained in the lab setting and the 39 operators trained locally at the hospital (P = 0.189). Implant case number was also not a determinant of procedural success (P = 0.456). Each operator performed between one and 55 procedures. Procedure time and fluoroscopy duration decreased by 2.0% (P = 0.002) and 3.2% (P safety outcomes by training method. Among a large group of operators, implantation success was high regardless of experience. While procedure duration and fluoroscopy times decreased with implant number, complications were low and not associated with case number. Procedure and safety outcomes were similar between distinct training methodologies. © 2017 Wiley Periodicals, Inc.

  3. Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Manolis, Antonis S.; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; de Sousa, João; Botto, Giovanni Luca; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2014-01-01

    Aims Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). Methods and results In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 ± 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55–0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77–1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52–0.85, P MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. ClinicalTrials.gov Identifier NCT00262119. PMID:24771721

  4. To pace or not to pace: a pilot study of four- and five-gaited Icelandic horses homozygous for the DMRT3 'Gait Keeper' mutation.

    Science.gov (United States)

    Jäderkvist Fegraeus, K; Hirschberg, I; Árnason, T; Andersson, L; Velie, B D; Andersson, L S; Lindgren, G

    2017-12-01

    The Icelandic horse is a breed known mainly for its ability to perform the ambling four-beat gait 'tölt' and the lateral two-beat gait pace. The natural ability of the breed to perform these alternative gaits is highly desired by breeders. Therefore, the discovery that a nonsense mutation (C>A) in the DMRT3 gene was the main genetic factor for horses' ability to perform gaits in addition to walk, trot and canter was of great interest. Although several studies have demonstrated that homozygosity for the DMRT3 mutation is important for the ability to pace, only about 70% of the homozygous mutant (AA) Icelandic horses are reported to pace. The aim of the study was to genetically compare four- and five-gaited (i.e. horses with and without the ability to pace) AA Icelandic horses by performing a genome-wide association (GWA) analysis. All horses (n = 55) were genotyped on the 670K Axiom Equine Genotyping Array, and a GWA analysis was performed using the genabel package in r. No SNP demonstrated genome-wide significance, implying that the ability to pace goes beyond the presence of a single gene variant. Despite its limitations, the current study provides additional information regarding the genetic complexity of pacing ability in horses. However, to fully understand the genetic differences between four- and five-gaited AA horses, additional studies with larger sample materials and consistent phenotyping are needed. © 2017 Stichting International Foundation for Animal Genetics.

  5. Effects of postshock atrial pacing on atrial defibrillation outcome in the isolated sheep heart

    NARCIS (Netherlands)

    Skanes, A. C.; Gray, R. A.; Zuur, C. L.; Jalife, J.

    1998-01-01

    BACKGROUND: Failed atrial defibrillation shocks are associated with organization of postshock activity and a substantial postshock electrical quiescence. We investigated the ability of a train of pacing stimuli to capture or locally entrain atrial myocardium during the quiescent period after

  6. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  7. PACE and the Medicare+Choice risk-adjusted payment model.

    Science.gov (United States)

    Temkin-Greener, H; Meiners, M R; Gruenberg, L

    2001-01-01

    This paper investigates the impact of the Medicare principal inpatient diagnostic cost group (PIP-DCG) payment model on the Program of All-Inclusive Care for the Elderly (PACE). Currently, more than 6,000 Medicare beneficiaries who are nursing home certifiable receive care from PACE, a program poised for expansion under the Balanced Budget Act of 1997. Overall, our analysis suggests that the application of the PIP-DCG model to the PACE program would reduce Medicare payments to PACE, on average, by 38%. The PIP-DCG payment model bases its risk adjustment on inpatient diagnoses and does not capture adequately the risk of caring for a population with functional impairments.

  8. Effects of Bepridil on Atrial Electrical Remodeling in Short-Term Rapid Pacing

    Directory of Open Access Journals (Sweden)

    Hiroto Tsuchiya, MD

    2009-01-01

    Conclusions: Bepridil prevented the shortening of the ERP and MAPD90 induced by rapid atrial pacing in the acute phase. The results of this study might explain the efficacy of bepridil for preventing the recurrence of paroxysmal AF.

  9. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    Science.gov (United States)

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  10. Synchronous intra-myocardial ventricular pacing without crossing the tricuspid valve or entering the coronary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Konecny, Tomas; DeSimone, Christopher V.; Friedman, Paul A.; Bruce, Charles [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Asirvatham, Samuel J., E-mail: asirvatham.samuel@mayo.edu [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Department of Pediatric and Adolescent Medicine, Pediatric Cardiology, Mayo Clinic, Rochester, MN (United States)

    2013-05-15

    Ventricular pacing is most commonly performed at the right ventricular (RV) apex. This is not without risk as placement requires crossing the tricuspid valve (TV) and may cause valvular dysfunction and dyssynchronous activation of the ventricles. The fact that the tricuspid valve lies more apically than the mitral valve allows for the possibility of pacing the ventricles from the right atrium (RA) via the “atrio-ventricular septum” without crossing the TV or entering the coronary sinus (CS). In order to mitigate far field activation inherent to current pacing technology, we constructed a novel lead in which the cathode and anode are both intra-myocardial. We demonstrate safety and efficacy of this novel lead for ventricular pacing at the atrio-ventricular septum in canines, including improved synchronous activation of both ventricles, improved differentiation in ventricular versus atrial sensing, while providing reliable ventricular capture, opening novel and a potentially safer alternative to human cardiac resynchronization therapy.

  11. EFFECT OF ADAPTIVE PACED CARDIOLOCOMOTOR SYNCHRONIZATION DURING RUNNING: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    Bill Phillips

    2013-09-01

    Full Text Available Cardiolocomotor synchronization (CLS has been well established for individuals engaged in rhythmic activity, such as walking, running, or cycling. When frequency of the activity is at or near the heart rate, entrainment occurs. CLS has been shown in many cases to improve the efficiency of locomotor activity, improving stroke volume, reducing blood pressure variability, and lowering the oxygen uptake (VO2. Instead of a 1:1 frequency ratio of activity to heart rate, an investigation was performed to determine if different harmonic coupling at other simple integer ratios (e.g. 1:2, 2:3, 3:2 could achieve any performance benefits. CLS was ensured by pacing the stride rate according to the measured heartbeat (i.e., adaptive paced CLS, or forced CLS. An algorithm was designed that determined the simplest ratio (lowest denominator that, when multiplied by the heart rate will fall within an individualized, predetermined comfortable pacing range for the user. The algorithm was implemented on an iPhone 4, which generated a 'tick-tock' sound through the iPhone's headphones. A sham-controlled crossover study was performed with 15 volunteers of various fitness levels. Subjects ran a 3 mile (4.83 km simulated training run at their normal pace on two consecutive days (randomized one adaptive pacing, one sham. Adaptive pacing resulted in faster runs run times, with subjects running an average of 26:03 ± 3:23 for adaptive pacing and 26:38 ± 3:31 for sham (F = 5.46, p < 0.05. The increase in heart rate from the start of the race as estimated by an exponential time constant was significantly longer during adaptive pacing, τ = 0.99 ± 0.30, compared to sham, τ = 1.53 ± 0.34 (t = -6.62, p < 0.01. Eighty-seven percent of runners found it easy to adjust their stride length to match the pacing signal with seventy-nine percent reporting that pacing helped their performance. These results suggest that adaptive paced CLS may have a beneficial effect on running

  12. Interatrial septum versus right atrial appendage pacing for prevention of atrial fibrillation : A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Zhang, L; Jiang, H; Wang, W; Bai, J; Liang, Y; Su, Y; Ge, J

    2017-07-28

    Interatrial septum (IAS) pacing seems to be a promising strategy for the prevention of atrial fibrillation (AF); however, studies have yielded conflicting results. This meta-analysis was to compare IAS with right atrial appendage (RAA) pacing on the prevention of postpacing AF occurrence. Pubmed, MEDLINE, EMBASE and Web of Science databases were searched through October 2016 for randomized controlled trials comparing IAS with RAA pacing on the prevention of AF. Data concerning study design, patient characteristics and outcomes were extracted. Risk ratio (RR), weighted mean differences (WMD) or standardized mean differences (SMD) were calculated using fixed or random effects models. A total of 12 trials involving 1146 patients with dual-chamber pacing were included. Although IAS was superior to RAA pacing in terms of reducing the number of AF episodes (SMD = -0.29, P = 0.05), AF burden (SMD = -0.41, P = 0.008) and P -wave duration (WMD = -34.45 ms, P IAS pacing. Nevertheless, no differences were observed concerning all-cause death (RR = 1.04, P = 0.88), procedure-related events (RR = 1.17, P = 0.69) and pacing parameters between IAS and RAA pacing in the follow-up period. IAS pacing is safe and as well tolerated as RAA pacing. Although IAS pacing may fail to prevent permanent AF occurrence and recurrences of AF, it is able to not only improve interatrial conduction, but also reduce AF burden.

  13. Infants' Visual Attention to Baby DVDs as a Function of Program Pacing

    Science.gov (United States)

    Gola, Alice Ann Howard; Calvert, Sandra L.

    2011-01-01

    This study examined the effects of program pacing, defined as the rate of scene and character change per minute, on infants' visual attention to video presentations. Seventy-two infants (twenty-four 6-month-olds, twenty-four 9-month-olds, twenty-four 12-month-olds) were exposed to one of two sets of high- and low-paced commercial infant DVDs. Each…

  14. Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs. Electrophysiological remodeling.

    Science.gov (United States)

    Elvan, A; Wylie, K; Zipes, D P

    1996-12-01

    We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.

  15. On the pace of fertility decline in sub-Saharan Africa

    OpenAIRE

    David Shapiro; Andrew Hinde

    2017-01-01

    Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa.Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world.Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they ...

  16. Effect of Music Tempo on Attentional Focus and Perceived Exertion during Self-selected Paced Walking

    OpenAIRE

    SILVA, ALDO COELHO; DOS SANTOS FERREIRA, SANDRO; ALVES, RAGAMI CHAVES; FOLLADOR, LUCIO; DA SILVA, SERGIO GREGORIO

    2016-01-01

    This study investigated the influence of music on the rating of perceived exertion (RPE) and attentional focus during walking at a self-selected pace. Fifteen overweight and obese women volunteered to participate in the study. They underwent four sessions: the first for incremental maximal test and anthropometric measurement followed by three experimental sessions. After the first session, they were exposed to three 30-minute walking sessions at a self-selected pace in a counterbalanced order...

  17. Wolbachia-induced loss of male fertility is likely related to branch chain amino acid biosynthesis and iLvE in Laodelphax striatellus.

    Science.gov (United States)

    Ju, Jia-Fei; Hoffmann, Ary A; Zhang, Yan-Kai; Duan, Xing-Zhi; Guo, Yan; Gong, Jun-Tao; Zhu, Wen-Chao; Hong, Xiao-Yue

    2017-06-01

    Wolbachia are endosymbionts that infect many species of arthropods and nematodes. Wolbachia-induced cytoplasmic incompatibility (CI) is the most common phenotype in affected hosts, involving embryonic lethality in crosses between Wolbachia-infected males and uninfected females. The molecular mechanisms underlying this phenomenon are currently unclear. Here we examine the molecular correlates of the Wolbachia infection in Laodelphax striatellus (Fallén), an important rice pest, where embryonic lethality is strong and almost complete. We compared the gene expression of 4-day-old Wolbachia-infected and uninfected L. striatellus testes to identify candidate genes for paternal-effect embryonic lethality induction. Based on microarray analysis, iLvE was the most down-regulated gene; this gene mediates branched-chain amino acid (BCAA) biosynthesis and participates in many processes related to reproductive performance. After knocking down iLvE by RNAi in uninfected male L. striatellus, male fertility was reduced, leading to a decrease in embryo hatching rates, but fertility was rescued in crosses between these males and Wolbachia-infected females. Removal of BCAA in chemically-defined diets of uninfected males also led to a loss of male fertility. Low amino acid nutrition may enhance exposure time of sperm to Wolbachia in the testes to affect adult reproduction in L. striatellus by reducing the number of sperm transferred per mating by males. These results indicate that Wolbachia may decrease male fertility in L. striatellus by acting on iLvE, a key factor of BCAA biosynthesis, and delaying sperm maturation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. A human factors experiment on the event-paced control tasks issue

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Chul; Park, Jae Chang; Oh, In Seok; Lee, Jung Woon; Lee, Ki Young; Park, Jong Kyun [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-03-01

    KEPRI(Korea Electric Power Research Institute) requires human factors validation tests according to the progress of the KNGR MMI design. This report describes the experimental results of an human factors validation issue, Event-Paced Control Tasks issue. The Event-Paced Control Task issue is to test that the designed MMI shall support operators in performing control tasks in pace with the plant dynamics. Task completion time and successful execution are defined as performance measures on the issue. Through an experiment on the issue with 3 scenarios and 5 subjects, we report that the variation of task completion time between subjects has a narrow band for each scenarios, however two among the total 15 experimental runs result in the failure that subject does not reach to the predefined operational goal. Incorrect operational strategy, insufficient training, and MMI design discrepancies are inferred as the causes of the failures. However these experimental results don't indicate the close of the Event-Paced Control Tasks issue. The validation test results under the experimental environment composed of the partial MMI representations, an unstable simulator, and insufficient subject training, are significant in the limited conditions. Thus, for the purpose of the complete issue close, the validation test on the Event-Paced Control Tasks issue should be repeatedly carried out in pace with the performance improvement of the experimental environment. 13 figs., 4 tabs. (Author)

  19. Effect of the Pacing Strategies on the Open Water 10km World Swimming Championships Performances.

    Science.gov (United States)

    Rodriguez, Luis; Veiga, Santiago

    2017-10-16

    The aim of the present research was 1) to compare the pacing strategies of different level open water swimmers during the 10km race of the FINA 2015 World Swimming Championships (WCH), and 2) to relate these pacing strategies to the race performance. Final and intermediate split times as well as intermediate race positions from the 10-kilometer race participants (69 men and 51 women) were collected from the public domain and were divided into five groups (G1 to G5) depending on their finishing positions. Medalists and finalists (G1 and G2, respectively) presented an even pacing profile with similar swimming velocities to the less successful swimmers (G3 to G5) on the initial and mid stages of the race but a 1.5-3% increase in swimming velocity in the last quarter of the race. This fast end spurt was largely related to the race performance and was not observed in the G3 and G4 (even-paced profile) or in the G5 (positive pacing profile) groups. Intermediate race positions and lap rankings were negatively related to finishing position indicating a delayed positioning of the most successful swimmers at 25%, 50% and 75% of race distance. The adoption of a conservative starting strategy by open water swimmers with a negative pacing profile and delayed partial positioning seems to increase the chances of overall race success as it allows a fast end spurt that is highly related to successful finishing race positions.

  20. Extending the use of the pacing pulmonary artery catheter for safe minimally invasive cardiac surgery.

    Science.gov (United States)

    Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G

    2010-08-01

    In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Optimal pacing strategy: from theoretical modelling to reality in 1500-m speed skating.

    Science.gov (United States)

    Hettinga, F J; De Koning, J J; Schmidt, L J I; Wind, N A C; Macintosh, B R; Foster, C

    2011-01-01

    Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing profile. Seven national-level speed-skaters performed a SP 1500-m which was analysed by obtaining velocity (every 100 m) and body position (every 200 m) with video to calculate total mechanical power output. Together with gross efficiency and aerobic kinetics, obtained in separate trials, data were used to calculate aerobic and anaerobic power output profiles. An energy flow model was applied to SP, simulating a range of pacing strategies, and a theoretically optimal pacing profile was imposed in a second race (IM). Final time for IM was ∼2 s slower than SP. Total power distribution per lap differed, with a higher power over the first 300 m for IM (637.0 (49.4) vs 612.5 (50.0) W). Anaerobic parameters did not differ. The faster first lap resulted in a higher aerodynamic drag coefficient and perhaps a less effective push-off. Experienced athletes have a well-developed performance template, and changing pacing strategy towards a theoretically optimal fast start protocol had negative consequences on speed-skating technique and did not result in better performance.

  2. A Pilot Study on the Effects of Slow Paced Breathing on Current Food Craving.

    Science.gov (United States)

    Meule, Adrian; Kübler, Andrea

    2017-03-01

    Heart rate variability biofeedback (HRV-BF) involves slow paced breathing (approximately six breaths per minute), thereby maximizing low-frequent heart rate oscillations and baroreflex gain. Mounting evidence suggests that HRV-BF promotes symptom reductions in a variety of physical and mental disorders. It may also positively affect eating behavior by reducing food cravings. The aim of the current study was to investigate if slow paced breathing can be useful for attenuating momentary food craving. Female students performed paced breathing either at six breaths per minute (n = 32) or at nine breaths per minute (n = 33) while watching their favorite food on the computer screen. Current food craving decreased during a first resting period, increased during paced breathing, and decreased during a second resting period in both conditions. Although current hunger increased in both conditions during paced breathing as well, it remained elevated after the second resting period in the nine breaths condition only. Thus, breathing rate did not influence specific food craving, but slow paced breathing appeared to have a delayed influence on state hunger. Future avenues are suggested for the study of HRV-BF in the context of eating behavior.

  3. Variation in turbidity with precipitation and flow in a regulated river system – River Göta Älv, SW Sweden

    OpenAIRE

    M. Larson; D. Bendz; G. Göransson

    2013-01-01

    The turbidity variation in time and space is investigated in the downstream stretch of the river Göta Älv in Sweden. The river is heavily regulated and carries the discharge from the largest fresh water lake in Sweden, Lake Vänern, to the outflow point in Göteborg Harbour on the Swedish west coast. The river is an important waterway and serves as a fresh-water supply for 700 000 users. Turbidity is utilised as a water quality indicator to ensure sufficient quality of the intake water to the t...

  4. DC-link Voltage Control to Compensate Voltage Deviation for PV–BESSs Integrated System in Low-Voltage (LV Networks

    Directory of Open Access Journals (Sweden)

    Lee Gyu-sub

    2016-01-01

    Full Text Available The exhaustion of fossil fuel and the greenhouse gas emission are one of the most significant energy and environmental issues, respectively. Photovoltaic (PV generators and battery energy storage systems (BESSs have been significantly increased for recent years. The BESSs are mainly used for smoothing active power fluctuation of the PV. In this paper, PV–BESSs integration of two DC/DC converters and one AC/DC converter is investigated and DC-link voltage control to compensate the AC voltage deviation is proposed for the PV‒BESS system in low-voltage (LV networks.

  5. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.

  6. Effects of Benzalkonium Chloride, Proxel LV, P3 Hypochloran, Triton X-100 and DOWFAX 63N10 on anaerobic digestion processes

    DEFF Research Database (Denmark)

    Flores, German Antonio Enriquez; Fotidis, Ioannis; Karakashev, Dimitar Borisov

    2015-01-01

    In this study, the individual and synergistic toxicity of the following xenobiotics: Benzalkonium Chloride (BKC), Proxel LV (PRX), P3 Hypochloran (HPC), Triton X-100 (TRX), and DOWFAX 63N10 (DWF), on anaerobic digestion (AD) process, was assessed. The experiments were performed in batch and conti......In this study, the individual and synergistic toxicity of the following xenobiotics: Benzalkonium Chloride (BKC), Proxel LV (PRX), P3 Hypochloran (HPC), Triton X-100 (TRX), and DOWFAX 63N10 (DWF), on anaerobic digestion (AD) process, was assessed. The experiments were performed in batch...... and continuous (up-flow anaerobic sludge blanket, UASB) reactors with biochemical-industrial wastewater, as substrate. In batch experiments, half-maximal inhibitory concentrations (IC50) for the tested xenobiotics were found to be 13.1, 1003, 311.5 and 24.3 mg L1 for BKC, PRX, DWF and TRX, respectively while HPC...... observed from the batch reactors. Oppositely, TRX showed no inhibition in continuous mode, while inhibition was detected at batch mode....

  7. Coinfection of Leishmania chagasi with Toxoplasma gondii, Feline Immunodeficiency Virus (FIV) and Feline Leukemia Virus (FeLV) in cats from an endemic area of zoonotic visceral leishmaniasis.

    Science.gov (United States)

    Sobrinho, Ludmila Silva Vicente; Rossi, Cláudio Nazaretian; Vides, Juliana Peloi; Braga, Eveline Tozzi; Gomes, Ana Amélia Domingues; de Lima, Valéria Marçal Félix; Perri, Sílvia Helena Venturoli; Generoso, Diego; Langoni, Hélio; Leutenegger, Christian; Biondo, Alexander Welker; Laurenti, Márcia Dalastra; Marcondes, Mary

    2012-06-08

    The aim of the present study was to determine the coinfection of Leishmania sp. with Toxoplasma gondii, Feline Immunodeficiency Virus (FIV) and Feline Leukemia Virus (FeLV) in a population of cats from an endemic area for zoonotic visceral leishmaniasis. An overall 66/302 (21.85%) cats were found positive for Leishmania sp., with infection determined by direct parasitological examination in 30/302 (9.93%), by serology in 46/302 (15.23%) and by both in 10/302 (3.31%) cats. Real time PCR followed by amplicon sequencing successfully confirmed Leishmania infantum (syn Leishmania chagasi) infection. Out of the Leishmania infected cats, coinfection with FIV was observed in 12/66 (18.18%), with T. gondii in 17/66 (25.75%) and with both agents in 5/66 (7.58%) cats. FeLV was found only in a single adult cat with no Leishmania infection. A positive association was observed in coinfection of Leishmania and FIV (p0.05). In conclusion, cats living in endemic areas of visceral leishmaniasis are significantly more likely to be coinfected with FIV, which may present confounding clinical signs and therefore cats in such areas should be always carefully screened for coinfections. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Variables affecting the manifestation of and intensity of pacing behavior: A preliminary case study in zoo-housed polar bears.

    Science.gov (United States)

    Cless, Isabelle T; Lukas, Kristen E

    2017-09-01

    High-speed video analysis was used to quantify two aspects of gait in 10 zoo-housed polar bears. These two variables were then examined as to how they differed in the conditions of pacing versus locomoting for each bear. Percent difference calculations measured the difference between pacing and locomoting data for each bear. We inferred that the higher the percent difference between pacing and locomoting in a given subject, the more intense the pacing may be. The percent difference values were analyzed alongside caregiver survey data defining the locations, frequency, and anticipatory nature of pacing in each bear, as well as each bear's age and sex, to determine whether any variables were correlated. The frequency and intensity of pacing behavior were not correlated. However, location of pacing was significantly correlated both with the subjects' age and whether or not the subject was classified as an anticipatory pacer. Bears appeared to select specific spots within their exhibits to pace, and the location therefore seemed tied to underlying motivation for the behavior. Additionally, bears that were classified in the survey as pacing anticipatorily displayed significantly more intense pacing behavior as quantified by gait analysis. © 2017 Wiley Periodicals, Inc.

  9. Improvement of Left Ventricular Function by Permanent Direct His-Bundle Pacing in a Case with Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Yukiko Sashida, MD

    2006-01-01

    Full Text Available The patient was a 67-year-old female diagnosed with dilated cardiomyopathy. She had chronic atrial fibrillation (AF with bradycardia and low left ventricular function (left ventricular ejection fraction (LVEF 40%. She was admitted for congestive heart failure. She remained New York Heart Association (NYHA functional class III due to AF bradycardia. Pacemaker implantation was necessary for treatment of heart failure and administration of dose intensive β-blockers. As she had normal His-Purkinje activation, we examined the optimal pacing sites. Hemodynamics of His-bundle pacing and biventricular pacing were compared. Pulmonary capillary wedge pressure (PCWP was significantly lower on Hisbundle pacing than right ventricular (RV apical pacing and biventricular pacing (13mmHg, 19mmHg, and 19mmHg, respectively with an almost equal cardiac index. Based on the examination we implanted a permanent pacemaker for Direct His-bundle pacing (DHBP. After the DHBP implantation, the LVEF immediately improved from 40% to 55%, and BNP level decreased from 422 pg/ml to 42 pg/ml. The number of premature ventricular complex (PVC was decreased, and non sustained ventricular tachycardia (NSVT disappeared. Pacing threshold for His-bundle pacing has remained at the same level. His-bundle pacing has been maintained during 27 months and her long-term DHBP can improve cardiac function and the NYHA functional class.

  10. A fast-start pacing strategy speeds pulmonary oxygen uptake kinetics and improves supramaximal running performance.

    Directory of Open Access Journals (Sweden)

    Tiago Turnes

    Full Text Available The focus of the present study was to investigate the effects of a fast-start pacing strategy on running performance and pulmonary oxygen uptake (VO2 kinetics at the upper boundary of the severe-intensity domain. Eleven active male participants (28±10 years, 70±5 kg, 176±6 cm, 57±4 mL/kg/min visited the laboratory for a series of tests that were performed until exhaustion: 1 an incremental test; 2 three laboratory test sessions performed at 95, 100 and 110% of the maximal aerobic speed; 3 two to four constant speed tests for the determination of the highest constant speed (HS that still allowed achieving maximal oxygen uptake; and 4 an exercise based on the HS using a higher initial speed followed by a subsequent decrease. To predict equalized performance values for the constant pace, the relationship between time and distance/speed through log-log modelling was used. When a fast-start was utilized, subjects were able to cover a greater distance in a performance of similar duration in comparison with a constant-pace performance (constant pace: 670 m±22%; fast-start: 683 m±22%; P = 0.029; subjects also demonstrated a higher exercise tolerance at a similar average speed when compared with constant-pace performance (constant pace: 114 s±30%; fast-start: 125 s±26%; P = 0.037. Moreover, the mean VO2 response time was reduced after a fast start (constant pace: 22.2 s±28%; fast-start: 19.3 s±29%; P = 0.025. In conclusion, middle-distance running performances with a duration of 2-3 min are improved and VO2 response time is faster when a fast-start is adopted.

  11. Preliminary results of pre-operative 5-FU, low dose leucovorin (LV), and concurrent radiation therapy (RT) for resectable T3 rectal cancer

    International Nuclear Information System (INIS)

    Grann, Alison; Minsky, Bruce D.; Cohen, Alfred M.; Saltz, Leonard; Kelsen, David P.; Kemeny, Nancy; Ilson, David; Guillem, Jose G.; Paty, Philip B.; Bass, Joanne

    1996-01-01

    PURPOSE: We report the downstaging, acute toxicity, and preliminary local control and survival of pre-op 5-FU, low dose LV, and concurrent RT followed by post-op LV/5-FU for pts with clinically resectable, T3 rectal cancer. MATERIALS AND METHODS: A total of 32 pts (M:26, F:6) were prospectively treated from 12/91-8/95. Eligibility criteria included adequate hematologic indicies, primary adenocarcinoma limited to the pelvis, and T3 disease confirmed by transrectal ultrasound. Twenty five pts were considered clinically to require an APR on initial (pre-treatment) assessment by their operating surgeon. The median age was 56 (range: 24-80), and the median distance from the anal verge was 5.0cm (range: 3-9cm). Pts received 2 monthly cycles (bolus daily X 5) of LV (20mg/m2) and 5-FU (325mg/m2), beginning concurrently with day 1 of RT, followed by surgery 4-5 weeks later. RT included 4680 cGy to the pelvis followed by a boost to 5040 cGy. Post-operatively, pts received a median of 2 monthly cycles (range: 0-10 cycles) of LV (20 mg/m2) and 5-FU (425mg/m2). A toxicity assessment was performed at each visit using the NCI toxicity criteria modified for gastrointestinal toxicity. The median follow-up was 12 months (range: 3-48 months). All 32 patients were included in the analysis of toxicity, sphincter preservation, and downstaging. Analysis of patterns of failure and survival was limited to the 15 pts who had a minimum follow-up of 1yr or developed failure prior to 1 yr. For this subset the median follow-up was 24 months (range: 3-48 months). RESULTS: During the pre-op segment, individual grade 3+ acute toxicities were; diarrhea: 16%, bowel movements: 16%, leukopenia: 12%. The incidence of total toxicity was 25% ((8(32))). The median nadir counts were; WBC: 2.9 (range: 1.7-5.6), HGB: 12.4 (range: 7.1-15.0), and PLT (X1000): 161 (range: 113-237). The pathologic complete response rate was 9% ((3(32))). An additional 13% ((4(32))) had negative lymph nodes and 1-2 microscopic

  12. Effect of Psychological Intervention on Marital Satisfaction of Mothers with Slow Pace Under 5 Years Children

    Directory of Open Access Journals (Sweden)

    Mehran Soleymani

    2012-04-01

    Full Text Available Objectives: Objective of this study was investigating impact of early psychological interventions on marital satisfaction of mothers with slow pace under 5 years children. Considering variables of the research, that is, early psychological interventions and marital satisfaction, research hypotheses was as follows: "early psychological interventions affect marital satisfaction of mothers with slow pace under 5 years children" and it was examined. Methods: This research is of experimental type and pretest-posttest plan with control groups was used. Statistical population included all mothers with slow pace under 5 years children in Urmia. To this end, 40 mothers with slow pace children were selected as the sample in a non-random manner by convenience sampling. They were assigned randomly into two groups of 20 (20 test group and 20 control group, and finally psychological interventions were conducted on one of groups randomly. In order to evaluate marital satisfaction, Enrich marital satisfaction questionnaire with 47 items was used. Data were analyzed by univariate analysis of covariance. Results: findings showed that there is significant difference between two groups in posttest in overall score of marital satisfaction as well as in some elements such as conventional responses, marital satisfaction, personality issues, marital relationships, conflict resolution, leisure, parenting, family and friends, and ideological orientation and sexual relations (P<0.005, and no significant difference was observed in financial supervision and roles related to gender equality. Discusion: Psychological interventions were effective in promoting marital satisfaction in mothers with slow pace under 5 years children.

  13. Atrial antitachycardia pacing and atrial remodeling: A substudy of the international, randomized MINERVA trial.

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Biffi, Mauro; Mont, Lluis; Ricci, Renato; Pürerfellner, Helmut; Botto, Giovanni Luca; Manolis, Antonis S; Landolina, Maurizio; Gulizia, Michele; Hudnall, J Harrison; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2017-10-01

    Atrial tachycardia (AT) and atrial fibrillation (AF) are common in pacemaker patients and are associated with bad prognoses. The purpose of this study was to evaluate atrial antitachycardia pacing impact on AT/AF-induced atrial remodeling, measured by early recurrence of AT/AF (ERAF) and by change in left atrial diameter (LAD), and to evaluate the impact of AT/AF duration on ERAF incidence. Pacemaker patients were randomized to dual-chamber pacing (Control DDDR: 385 patients), managed ventricular pacing (MVP: 398 patients), or atrial antitachycardia pacing plus MVP (DDDRP+MVP: 383 patients). LAD change, estimated by echocardiography, was considered significant if the relative difference between baseline and 24-month measurements was >10%. At median follow-up of 34 months, ERAF incidence was significantly lower in the DDDRP+MVP arm for all AT/AF durations, in particular, ERAF followed AT/AF longer than 3 hours in 53% cases in Control DDDR, in 51% cases in MVP, and in 39% cases in DDDRP+MVP (P MVP, and 70% in DDDRP+MVP (P MVP, DDDRP+MVP reduces ERAF and favors LAD reduction, suggesting that atrial antitachycardia pacing may reverse electrical and mechanical remodeling. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    Science.gov (United States)

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  15. Deviation from goal pace, body temperature and body mass loss as predictors of road race performance.

    Science.gov (United States)

    Adams, William M; Hosokawa, Yuri; Belval, Luke N; Huggins, Robert A; Stearns, Rebecca L; Casa, Douglas J

    2017-03-01

    The purpose of this study was to examine the relationship between pacing, gastrointestinal temperature (T GI ), and percent body mass loss (%BML) on relative race performance during a warm weather 11.3km road race. Observational study of a sample of active runners competing in the 2014 Falmouth Road Race. Participants ingested a T GI pill and donned a GPS enabled watch with heart rate monitoring capabilities prior to the start of the race. Percent off predicted pace (% OFF ) was calculated for seven segments of the race. Separate linear regression analyses were used to assess the relationship between pace, T ​GI , and %BML on relative race performance. One-way ANOVA was used to analyse post race T GI (≥40°C vs 0.05). There was a trend in a slower pace (p=0.055) and greater % OFF (p=0.056) in runners finishing the race with a T GI >40°C. Overall, finish time was influenced by greater variations in pace during the first two miles of the race. In addition, runners who minimized fluid losses and had lower T GI were associated with meeting self-predicted goals. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Atrial pacing and thallium 201 scintigraphy: combined use for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Stratmann, H.G.; Mark, A.L.; Walter, K.E.; Fletcher, J.W.; Williams, G.A.

    1987-01-01

    To evaluate the presence of coronary artery disease (CAD), atrial pacing and thallium 201 scintigraphy were performed in 36 patients with stable angina pectoris who were unable to perform an adequate exercise stress test. All patients underwent cardiac catheterization. Nine patients had previously undergone coronary artery bypass surgery. Significant CAD (one or more lesions greater than or equal to 50%) was present in 33 patients. Atrial pacing produced ischemic ST segment depression (greater than or equal to 1 mm) in 18 (55%) patients with CAD, and angina in 20 patients (61%). As the number of vessels with CAD increased, there was no significant change in the sensitivities of pacing-induced angina or ST segment depression for detecting CAD. In the 3 patients without CAD, ST segment depression occurred in 1 patient and angina in none. Thallium 201 scintigraphy demonstrated perfusion defects in 27 (82%) patients with CAD, with fixed defects seen in 13 studies (39%) and reversible defects in 15 (45%). In the 3 patients without CAD, no perfusion defects were seen. The thallium 201 scan successfully predicted the presence of CAD in patients with single-vessel disease but usually underestimated the number of vessels involved in patients with multivessel disease. Combined sensitivity of pacing-induced ST segment depression and an abnormal thallium 201 scan finding for detecting CAD was 91%. The authors conclude that combined atrial pacing and thallium 201 scintigraphy is a useful test for detecting CAD in patients unable to perform an adequate exercise stress test

  17. Application of PACE Principles for Population Health Management of Frail Older Adults.

    Science.gov (United States)

    Stefanacci, Richard G; Reich, Shelley; Casiano, Alex

    2015-10-01

    To determine which practices would have the most impact on reducing hospital and emergency department admissions and nursing home placement among older adults with multiple comorbid conditions, a literature search and survey were conducted to identify and prioritize comprehensive care principles as practiced in the Program of All-inclusive Care for the Elderly (PACE). PACE medical directors and members of the PACE interdisciplinary team (IDT) were surveyed to gain their insights on the most impactful practices, which were identified as: End-of-Life Management, Caregiver Support, Management of Red Flags, Medication Management, Participant and Caregiver Health Care System Literacy, and Care Coordination. In addition, this research evaluated measures that could be used to assess an organization's level of success with regard to each of the 6 PACE practices identified. The results reported in this article, found through a survey with PACE medical directors and IDT members concerning effective interventions, can be viewed as strategies to improve care for older adults, enabling them to maintain their independence in the community, avoid the expense of facility-based care, and enhance their quality of life.

  18. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    Science.gov (United States)

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  19. An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR : A manikin study

    OpenAIRE

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-01-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-secon...

  20. Specification of requirements to get a license for an Independent Spent Fuel Dry Storage Installation (ISFSI) at the site of the NPP-LV

    International Nuclear Information System (INIS)

    Serrano R, M. L.

    2015-09-01

    This article describes some of the work done in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) to define specifically the requirements that the Federal Electricity Commission (CFE) shall meet to submit for consideration of CNSNS an operation request of an Independent Spent Fuel Dry Storage Installation (ISFSI). The project of a facility of this type arose from the need to provide storage capacity for spent nuclear fuel in the nuclear power plant of Laguna Verde (NPP-LV) and to continue the operation at the same facility in a safe manner. The licensing of these facilities in the United States of America has two modes: specific license or general license. The characteristics of these licenses are described in this article. However, in Mexico the existing national legislation is not designed for such license types, in fact there is a lack of standards or regulations in this regard. The regulatory law of Article 27 of the Constitution in the nuclear matter, only generally establishes that this type of facility requires an authorization from the Ministry of Energy. For this reason and because there is not a national legislation, was necessary to use the legislation that provides the Nuclear Regulatory Commission of USA, the US NRC. However, it cannot be applied as is established, so was necessary that the CNSNS analyze one by one the requirements of both types of license and determine what would be required to NPP-LV to submit its operating license of ISFSI. The American regulatory applicable to an ISFSI, the 10-Cfr-72 of the US NRC, establishes the requirements for both types of licenses. Chapter 10-Cfr was analyzed in all its clauses and coupled to the laws, regulations and standards as well as to the requirements established by CNSNS, all associated with a store spent fuel on site; the respective certification of containers for spent fuel dry storage was not included in this article, even though the CNSNS also performed that activity under the

  1. Paleoceanographic Changes Since the Last Glacial as Revealed by Analysis of Alkenone Organic Biomarkers from the Northwest Pacific (Core LV 63-41-2)

    Science.gov (United States)

    Yu, P. S.; Liao, C. J.; Chen, M. T.; Zou, J. J.; Shi, X.; Bosin, A. A.; Gorbarenko, S. A.

    2017-12-01

    Sea surface temperature (SST) records from the subarctic Northwestern (NW) Pacific are ideal for reconstructing regional paleoceanographic changes sensitive to global climate change. Core LV 63-41-2 (52.56°N, 160.00° E; water depth 1924 m) retrieved from a high sedimentation site, in which the interactions of the Bering Sea and the warm water mass from the NW Pacific are highly dynamic. Here we reported high-resolution last glacial alkenone-based records from Core LV 63-41-2. Prior to 27-16 ka BP high glacial C37:4 alkenone concentrations indicate large amount of fresh water influencing the surface water of the NW Pacific with a reaching to the Site LV 63-41-2. We further inferred that during the last glacial the low salinity water may be formed from the ice-melting water on site and/or brought by the surface current from the Bering Sea, and are efficient in producing strong water stratification condition. The stratification weakens vertical mixing of the upper water column, that in turn decreases the nutrients upwelled from deep to the surface therefore causes low productivity of coccolithophorids. During the early Bølling-Allerød (B/A) period, a gradual increasing alkenone-SST and associated with high C37:4 alkenone concentrations, implying that a weakened stratification and much stronger nutrient upwelling of the early B/A period than that of the glacial. The late B/A period is characterized by an abrupt warming with possibly more melting sea ices in the Bering Sea and the coast near the Kamchatka Peninsula. The large amount of fresh water lens formed during the ice melting might have ceased vertical mixing and upwelling in the upper water column as evidenced by a decline of biological productivity of both calcerous and soliceous organism during late B/A. We suggest an early warming and low productivity in the NW Pacific that is coincident with a rapid cooling in most of the Northern Hemisphere high latitudes during the Younger Dryas.

  2. Effect of atrial pacing on phase analysis in patients with the Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Magosaki, Nobuhisa; Hiroe, Michiaki; Kasanuki, Hiroshi; Ohnishi, Satoshi; Tanaka, Etsuko; Horie, Toshinobu; Kusakabe, Kiyoko; Kondo, Mizuka; Hirosawa, Koshichiro

    1984-01-01

    Phase analysis of ECG-gated radionuclide ventriculography was performed during sinus rhythm and atrial pacing for 11 patients with the Wolff-Parkinson-White (WPW) syndrome. During sinus rhythm, phase analysis demonstrated abnormal early-emptying segments reflecting preexcitation in six of the 11 patients. In the remaining five patients, the precise site of abnormal early-emptying could not be detected. Atrial pacing increased the degree of pre-exicitation, and abnormal early-emptying segments became clear in all patients. Our study demonstrated the utility of atrial pacing in performing phase analysis for patients with the WPW syndrome. Seven patients had abnormal early-emptying segments; four of them with ECG type A, in the left ventricle, and three of them with ECG type B, in the right ventricle. These results were consistent with results of the body surface and electrophysiologic mapping. In patients with posterior septal accessory pathways, phase analysis suggested probable laterality of the accessory pathway. (author)

  3. Metabolic Responses and Pacing Strategies during Successive Sprint Skiing Time Trials

    DEFF Research Database (Denmark)

    Andersson, Erik; Holmberg, Hans-Christer; Ørtenblad, Niels

    2016-01-01

    PURPOSE: To examine the metabolic responses and pacing strategies during the performance of successive sprint time trials (STTs) in cross-country skiing. METHODS: Ten well-trained male cross-country skiers performed four self-paced 1300-m STTs on a treadmill, each separated by 45 min of recovery...... to estimate the anaerobic energy supply. RESULTS: The individual trial-to-trial variability in STT performance time was 1.3%, where variations in O2 deficit and V˙O2 explained 69% (P 0.05) of the variation in performance. The first and last STTs were equally fast (228 ± 10 s), and ~ 1...... on the first than second course half. In addition, metabolic rates were substantially higher (~_30%) for uphill than for flat skiing, indicating that pacing was regulated to the terrain. CONCLUSIONS: The fastest STTs were characterized primarily by a greater anaerobic energy production, which also explained 69...

  4. Toxoplasma gondii, Dirofilaria immitis, feline immunodeficiency virus (FIV), and feline leukemia virus (FeLV) infections in stray and pet cats (Felis catus) in northwest China: co-infections and risk factors.

    Science.gov (United States)

    Cong, Wei; Meng, Qing-Feng; Blaga, Radu; Villena, Isabelle; Zhu, Xing-Quan; Qian, Ai-Dong

    2016-01-01

    This study was conducted to estimate the prevalence of Toxoplasma gondii, Dirofilaria immitis, feline immunodeficiency virus (FIV), and feline leukemia virus (FeLV) infections among stray and pet cats in Lanzhou, northwest China, and to identify the influence of age, gender, and regions on seropositivity. T. gondii antibodies were examined in cat sera by the modified agglutination test (MAT). The circulating antigens of D. immitis and FeLV and specific antibodies to FIV were examined using kits commercially available. The overall prevalence of T. gondii, FIV, FeLV, and D. immitis was 19.34, 9.12, 11.33, and 3.04 %, respectively. For the genetic characterization of T. gondii genotypes in cats, genomic DNA was extracted from the seropositive cats and the T. gondii B1 gene was amplified using a semi-nested PCR. DNA samples giving positive B1 amplification were then genotyped using multilocus PCR-RFLP. Two T. gondii genotypes (ToxoDB#9 and ToxoDB#1) were identified. Results of the multivariate logistic regression analysis showed that older cats are more likely to be seropositive than juveniles for T. gondii, FIV, FeLV, and D. immitis. This is the first report of T. gondii genotypes in cats in northwest China. Moreover, the present study is the first study of retrovirus and D. immitis seroprevalence in cats in China. The results revealed that T. gondii, FIV, and FeLV infections are common in stray and pet cats in northwest China.

  5. A Monetary Reward Alters Pacing but Not Performance in Competitive Cyclists.

    Science.gov (United States)

    Skorski, Sabrina; Thompson, Kevin G; Keegan, Richard J; Meyer, Tim; Abbiss, Chris R

    2017-01-01

    Money has frequently been used as an extrinsic motivator since it is assumed that humans are willing to invest more effort for financial reward. However, the influence of a monetary reward on pacing and performance in trained athletes is not well-understood. Therefore, the aim of this study was to analyse the influence of a monetary reward in well-trained cyclists on their pacing and performance during short and long cycling time trials (TT). Twentythree cyclists (6 ♀, 17 ♂) completed 4 self-paced time trials (TTs, 2 short: 4 km and 6 min; 2 long: 20 km and 30 min); in a randomized order. Participants were separated into parallel, non-randomized "rewarded" and "non-rewarded" groups. Cyclists in the rewarded group received a monetary reward based on highest mean power output across all TTs. Cyclists in the non-rewarded group did not receive a monetary reward. Overall performance was not significantly different between groups in short or long TTs ( p > 0.48). Power output showed moderatly lower effect sizes at comencement of the short TTs ( P meandiff = 36.6 W; d > 0.44) and the 20 km TT ( P meandiff = 22.6 W; d = 0.44) in the rewarded group. No difference was observed in pacing during the 30 min TT ( p = 0.95). An external reward seems to have influenced pacing at the commencement of time trials. Participants in the non-rewarded group adopted a typical parabolic shaped pattern, whereas participants in the rewarded group started trials more conservatively. Results raise the possibility that using money as an extrinsic reward may interfere with regulatory processes required for effective pacing.

  6. RIght VErsus Left Apical transvenous pacing for bradycardia: Results of the RIVELA randomized study

    Directory of Open Access Journals (Sweden)

    Haran Burri

    2017-11-01

    Full Text Available Aims: To compare cardiac function when pacing from the right or left ventricular apex in patients with preserved left ventricular systolic function, at 1-year follow-up. Methods: Prospective, multicentre centre randomizing conventional right ventricular apical (RVA versus left ventricular apical (LVA pacing using a coronary sinus lead in patients requiring ventricular pacing for bradycardia. Follow-up was performed using 3D-echocardiography at 6 and 12 months. Results: A total of 36 patients (age 75.4 ± 8.7 years, 21 males were enrolled (17 patients in the RVA group and 19 patients in the LVA group. A right ventricular lead was implanted in 8 patients in the LVA group, mainly because of high capture thresholds. There were no differences in the primary endpoint of LVEF at 1 year (60.4 ± 7.1% vs 62.1 ± 7.2% for the RVA and LVA groups respectively, P = 0.26 nor in any of the secondary endpoints (left ventricular dimensions, left ventricular diastolic function, right ventricular systolic function and tricuspid/mitral insufficiency. LVEF did not change significantly over follow-up in either group. Capture thresholds were significantly higher in the LVA group, and two patients had unexpected loss of capture of the coronary sinus lead during follow-up. Conclusions: Left univentricular pacing seems to be comparable to conventional RVA pacing in terms of ventricular function at up to 1 year follow-up, and is an option to consider in selected patients (e.g. those with a tricuspid valve prosthesis. Keywords: Ventricular pacing, Right ventricle, Left ventricle, Coronary sinus, Ventricular function

  7. A Monetary Reward Alters Pacing but Not Performance in Competitive Cyclists

    Directory of Open Access Journals (Sweden)

    Sabrina Skorski

    2017-09-01

    Full Text Available Money has frequently been used as an extrinsic motivator since it is assumed that humans are willing to invest more effort for financial reward. However, the influence of a monetary reward on pacing and performance in trained athletes is not well-understood. Therefore, the aim of this study was to analyse the influence of a monetary reward in well-trained cyclists on their pacing and performance during short and long cycling time trials (TT. Twentythree cyclists (6 ♀, 17 ♂ completed 4 self-paced time trials (TTs, 2 short: 4 km and 6 min; 2 long: 20 km and 30 min; in a randomized order. Participants were separated into parallel, non-randomized “rewarded” and “non-rewarded” groups. Cyclists in the rewarded group received a monetary reward based on highest mean power output across all TTs. Cyclists in the non-rewarded group did not receive a monetary reward. Overall performance was not significantly different between groups in short or long TTs (p > 0.48. Power output showed moderatly lower effect sizes at comencement of the short TTs (Pmeandiff = 36.6 W; d > 0.44 and the 20 km TT (Pmeandiff = 22.6 W; d = 0.44 in the rewarded group. No difference was observed in pacing during the 30 min TT (p = 0.95. An external reward seems to have influenced pacing at the commencement of time trials. Participants in the non-rewarded group adopted a typical parabolic shaped pattern, whereas participants in the rewarded group started trials more conservatively. Results raise the possibility that using money as an extrinsic reward may interfere with regulatory processes required for effective pacing.

  8. Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.

    Science.gov (United States)

    O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E

    2018-04-26

    Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.

  9. Modeling parameters that characterize pacing of elite female 800-m freestyle swimmers.

    Science.gov (United States)

    Lipińska, Patrycja; Allen, Sian V; Hopkins, Will G

    2016-01-01

    Pacing offers a potential avenue for enhancement of endurance performance. We report here a novel method for characterizing pacing in 800-m freestyle swimming. Websites provided 50-m lap and race times for 192 swims of 20 elite female swimmers between 2000 and 2013. Pacing for each swim was characterized with five parameters derived from a linear model: linear and quadratic coefficients for effect of lap number, reductions from predicted time for first and last laps, and lap-time variability (standard error of the estimate). Race-to-race consistency of the parameters was expressed as intraclass correlation coefficients (ICCs). The average swim was a shallow negative quadratic with slowest time in the eleventh lap. First and last laps were faster by 6.4% and 3.6%, and lap-time variability was ±0.64%. Consistency between swimmers ranged from low-moderate for the linear and quadratic parameters (ICC = 0.29 and 0.36) to high for the last-lap parameter (ICC = 0.62), while consistency for race time was very high (ICC = 0.80). Only ~15% of swimmers had enough swims (~15 or more) to provide reasonable evidence of optimum parameter values in plots of race time vs. each parameter. The modest consistency of most of the pacing parameters and lack of relationships between parameters and performance suggest that swimmers usually compensated for changes in one parameter with changes in another. In conclusion, pacing in 800-m elite female swimmers can be characterized with five parameters, but identifying an optimal pacing profile is generally impractical.

  10. Activation of the Prefrontal Cortex While Performing a Task at Preferred Slow Pace and Metronome Slow Pace: A Functional Near-Infrared Spectroscopy Study

    Directory of Open Access Journals (Sweden)

    Kaori Shimoda

    2014-01-01

    Full Text Available Individuals have a preferred pace at which they perform voluntary repetitive movements. Previous studies have reported that greater activation of the prefrontal cortex was observed during self-initiated movements than during externally triggered movements. The purpose of the present study is to compare the activation of the prefrontal cortex induced when the subjects performed a peg-board task at their preferred slow pace (PSP, the self-initiated condition with that induced when they performed the same task at metronome slow pace (MSP, the externally triggered condition using functional near-infrared spectroscopy. Healthy subjects performed the task while sitting in a chair. By assessing the activated channels individually, we confirmed that all of the prefrontal regions of interest were activated by both tasks. In the second-level analyses, we found that the activation detected in the frontopolar cortex (FPPFC; Brodmann area 10 was higher during the PSP task than during the MSP task. The FPPFC is known to be at the top of prefrontal hierarchy, and specifically involved in evaluating self-generated information. In addition, the FPPFC plays a role in coordinating lateral prefrontal cortex. In the present study, the subjects evaluated and managed the internally generated PSP by coordinating the activity of other lower level prefrontal regions.

  11. Activation of the prefrontal cortex while performing a task at preferred slow pace and metronome slow pace: a functional near-infrared spectroscopy study.

    Science.gov (United States)

    Shimoda, Kaori; Moriguchi, Yoshiya; Tsuchiya, Kenji; Katsuyama, Shiori; Tozato, Fusae

    2014-01-01

    Individuals have a preferred pace at which they perform voluntary repetitive movements. Previous studies have reported that greater activation of the prefrontal cortex was observed during self-initiated movements than during externally triggered movements. The purpose of the present study is to compare the activation of the prefrontal cortex induced when the subjects performed a peg-board task at their preferred slow pace (PSP, the self-initiated condition) with that induced when they performed the same task at metronome slow pace (MSP, the externally triggered condition) using functional near-infrared spectroscopy. Healthy subjects performed the task while sitting in a chair. By assessing the activated channels individually, we confirmed that all of the prefrontal regions of interest were activated by both tasks. In the second-level analyses, we found that the activation detected in the frontopolar cortex (FPPFC; Brodmann area 10) was higher during the PSP task than during the MSP task. The FPPFC is known to be at the top of prefrontal hierarchy, and specifically involved in evaluating self-generated information. In addition, the FPPFC plays a role in coordinating lateral prefrontal cortex. In the present study, the subjects evaluated and managed the internally generated PSP by coordinating the activity of other lower level prefrontal regions.

  12. Failure of communication and capture: The perils of temporary unipolar pacing system.

    Science.gov (United States)

    Sahinoglu, Efe; Wool, Thomas J; Wool, Kenneth J

    2015-06-01

    We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  13. Failure of communication and capture: The perils of temporary unipolar pacing system

    Directory of Open Access Journals (Sweden)

    Efe Sahinoglu, BChE

    2015-06-01

    Full Text Available We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  14. Pacing Lead-Induced Granuloma in the Atrium: A Foreign Body Reaction to Polyurethane

    Directory of Open Access Journals (Sweden)

    Shinagawa Yoko

    2013-01-01

    Full Text Available We described a case of an 82-year-old male who presented with a granuloma entrapping the polyurethane-coated pacing lead at the site of contact on the atrium. He had been paced for 8 years without symptoms or signs suggestive of an allergic reaction to the pacemaker system and died from thrombosis of the superior mesenteric artery and heart failure. A histological examination of the nodule showed an incidental granuloma with multinucleated giant cells. No granuloma was found in the heart or the lung.

  15. MCTS self-paced training kit (exam 70-680) configuring Windows 7

    CERN Document Server

    McLean, Ian

    2010-01-01

    NOTE: The most recent printings of this title incorporate corrections to errors found in the earlier printings. This Self-Paced Training Kit is designed to help maximize your performance on 70-680, the required exam for the Microsoft® Certified Technology Specialist (MCTS): Windows 7, Configuration certification.This 2-in-1 kit includes the official Microsoft study guide, plus practice tests on CD to help you assess your skills. It comes packed with the tools and features exam candidates want most-including in-depth, self-paced training based on final exam content; rigorous, objective-by-obj

  16. The effects of presentation pace and modality on learning a multimedia science lesson

    Science.gov (United States)

    Chung, Wen-Hung

    Working memory is a system that consists of multiple components. The visuospatial sketchpad is the main entrance for visual and spatial information, whereas acoustic and verbal information is processed in the phonological loop. The central executive works as a coordinator of information from these two subsystems. Numerous studies have shown that working memory has a very limited capacity. Based on these characteristics of working memory, theories such as cognitive load theory and the cognitive theory of multimedia learning provide multimedia design principles. One of these principles is that when verbal information accompanying pictures is presented in audio mode instead of visually, learning can be more effective than if both text and pictures are presented visually. This is called the modality effect. However, some studies have found that the modality effect does not occur in some situations. In most experiments examining the modality effect, the multimedia is presented as system-paced. If learners are able to repeat listening as many times as they need, the superiority of spoken text over visual text seems lessened. One aim of this study was to examine the modality effect in a learner-controlled condition. This study also used the one-word-at-a-time technique to investigate whether the modality effect would still occur if both reading and listening rates were equal. There were 182 college students recruited for this study. Participants were randomly assigned to seven groups: a self-paced listening group, a self-paced reading group, a self text-block reading group, a general-paced listening group, a general-paced reading group, a fast-paced listening group, and a fast-paced reading group. The experimental material was a cardiovascular multimedia module. A three-by-two between-subjects design was used to test the main effect. Results showed that modality effect was still present but not between the self-paced listening group and the self text-block reading group

  17. Time perception, pacing and exercise intensity: maximal exercise distorts the perception of time

    OpenAIRE

    Edwards, A. M.; McCormick, A.

    2017-01-01

    Introduction\\ud \\ud Currently there are no data examining the impact of exercise on the perception of time, which is surprising as optimal competitive performance is dependent on accurate pacing using knowledge of time elapsed.\\ud \\ud \\ud Methods\\ud \\ud With institutional ethics approval, 12 recreationally active adult participants (f = 7, m = 5) undertook both 30 s Wingate cycles and 20 min (1200 s) rowing ergometer bouts as short and long duration self-paced exercise trials, in each of thre...

  18. International piping benchmarks: use of the simplified code PACE 2. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J T; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom); ed.

    1979-05-15

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost.

  19. Single lead atrial vs. dual chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Brandt, Niels H; Kirkfeldt, Rikke Esberg; Nielsen, Jens Cosedis

    2017-01-01

    Aims The DANPACE trial randomized patients with sick sinus syndrome (SSS) to single lead atrial (AAIR) or dual chamber (DDDR) pacemaker (PM). After 5 years follow-up, no difference in overall survival, stroke or heart failure (HF) was observed, whereas risk of atrial fibrillation (AF) and PM...... This register-based long-term follow-up study indicates that there is no difference in mortality among patients with SSS randomized to AAIR or DDDR pacing, even with very long follow-up. Nor is there any difference in risk of AF hospitalization, stroke or HF. The higher rate of pacing mode-change to DDDR...

  20. Pacing, packing and sex-based differences in Olympic and IAAF World Championship marathons.

    Science.gov (United States)

    Hanley, Brian

    2016-09-01

    The aim of this study was to describe pacing profiles and packing behaviours of athletes in Olympic and World Championship marathons. Finishing and split times were collated for 673 men and 549 women across nine competitions. The mean speeds for each intermediate 5 km and end 2.2 km segments were calculated. Medallists of both sexes maintained even-paced running from 10 km onwards whereas slower finishers dropped off the lead pack at approximately half-distance. Athletes who ran with the same opponents throughout slowed the least in the second half (P tactics adopted and design training programmes accordingly.

  1. Development of tools to manage the operational monitoring and pre-design of the NPP-LV cycle; Desarrollo de herramientas para administrar el seguimiento operativo y el pre-diseno del ciclo de la CLV

    Energy Technology Data Exchange (ETDEWEB)

    Perusquia, R.; Arredondo S, C.; Hernandez M, J. L.; Montes T, J. L.; Castillo M, A.; Ortiz S, J. J., E-mail: raul.perusquia@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    This paper presents the development of tools to facilitate the management so much, the operational monitoring of boiling water reactors (BWR) of the nuclear power plant of Laguna Verde (NPP-LV) through independent codes, and how to carry out the static calculations corresponding to process of optimized pre-design of the reference cycle next to current cycle. The progress and preliminary results obtained with the program SACal, developed at Instituto Nacional de Investigaciones Nucleares (ININ), central tool to achieve provide a management platform of the operational monitoring and pre-design of NPP-LV cycle are also described. The reached preliminary advances directed to get an Analysis center and automated design of fuel assembly cells are also presented, which together with centers or similar modules related with the fuel reloads form the key part to meet the targets set for the realization of a Management Platform of Nuclear Fuel of the NPP-LV. (Author)

  2. Causes and implications of the slow pace of technology transfer and ...

    African Journals Online (AJOL)

    The major problem facing most developing countries today is the need to transform their agricultural industries from one depending on traditional inputs with low productivity to one based on modern input with higher productivity. The study was set up to examine the causes and implication of slow pace of technology transfer ...

  3. Effects of wind application on thermal perception and self-paced performance

    NARCIS (Netherlands)

    Teunissen, L.P.J.; Haan, A. de; Koning, J.J. de; Daanen, H.A.M.

    2013-01-01

    Physiological and perceptual effects of wind cooling are often intertwined and have scarcely been studied in self-paced exercise. Therefore, we aimed to investigate (1) the independent perceptual effect of wind cooling and its impact on performance and (2) the responses to temporary wind cooling

  4. Leveraging Technology to Alleviate Student Bottlenecks: The Self-Paced Online Tutorial--Writing (SPOT)

    Science.gov (United States)

    Moore, Scott D.; Sanchez, Rudolph J.; Inoue, Asao B.; Statham, Russel D.; Zelezny, Lynnette; Covino, William A.

    2014-01-01

    The Self-Paced Online Tutorial (SPOT) represents the best kind of innovation because it uses digital technologies wisely and because it is based on well-established theory, research, and practice. Extended education plays a pivotal role in the attainment of the California State University's (CSU) vision of providing a high-quality, affordable, and…

  5. Dynamic hyperinflation after metronome-paced hyperventilation in COPD--a 2 year follow-up.

    NARCIS (Netherlands)

    Hannink, J.D.C.; Lahaije, A.J.; Bischoff, E.W.M.A.; Helvoort, H.A.C. van; Dekhuijzen, R.; Schermer, T.R.J.; Heijdra, Y.F.

    2010-01-01

    In contrast to the decline in FEV(1), the behavior of dynamic hyperinflation (DH) over time is unknown in patients with COPD. Metronome-paced hyperventilation (MPH) is a simple applicable surrogate for exercise to detect DH. OBJECTIVE: To evaluate changes in MPH-induced DH during two years follow-up

  6. Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation

    NARCIS (Netherlands)

    Lahaije, A.J.M.C.; Willems, L.M.; Hees, H.W. van; Dekhuijzen, P.N.R.; Helvoort, H.A.C. van; Heijdra, Y.F.

    2013-01-01

    INTRODUCTION: This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this

  7. PACE VII. Curriculum Counts: Planning for Success through Developmentally Appropriate Movement Activities.

    Science.gov (United States)

    Indiana State Dept. of Education, Indianapolis.

    This volume contains summaries of 13 presentations at the PACE (Positive Approaches to Children's Education) conference. The titles are: "Fabulous Fitness Fun" (Deborah L. Arfman); "Manipulative Equipment Modified for Success" (Noel Bewley); "Fitness Play-Focus on Fun" (Noel Bewley); "Keeping Them All Moving:…

  8. Performance on Paced Auditory Serial Addition Test and cerebral blood flow in multiple sclerosis

    NARCIS (Netherlands)

    D'haeseleer, M.; Steen, C.; Hoogduin, J. M.; van Osch, M. J. P.; Fierens, Y.; Cambron, M.; Koch, M. W.; De Keyser, J.

    BackgroundTo assess the relationship between performance on the Paced Auditory Serial Addition Test (PASAT) and both cerebral blood flow (CBF) and axonal metabolic integrity in normal appearing white matter (NAWM) of the centrum semiovale in patients with multiple sclerosis (MS). MethodsNormal

  9. Pacing Strategy, Muscle Fatigue and Technique in 1500m Speed Skating and Cycling Time-Trials

    NARCIS (Netherlands)

    Stoter, Inge K; MacIntosh, Brian R; Fletcher, Jared R; Pootz, Spencer; Zijdewind, Inge; Hettinga, Florentina J

    2016-01-01

    PURPOSE: To evaluate pacing behavior and peripheral and central contributions to muscle fatigue in 1500m speed skating and cycling time-trials, when a faster or slower start is instructed. METHODS: Nine speed skaters and nine cyclists, all competing at regional or national level, performed two 1500m

  10. 1998 survey of cardiac pacing in South Africa report of the working ...

    African Journals Online (AJOL)

    1998 survey of cardiac pacing in South Africa report of the working group on registries of the Cardiac Arrhythmia Society of South Africa (CASSA). RN Scott Millar. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals ...

  11. Keeping Pace with K-12 Digital Learning: An Annual Review of Policy and Practice. Eleventh Edition

    Science.gov (United States)

    Watson, John; Pape, Larry; Murin, Amy; Gemin, Butch; Vashaw, Lauren

    2014-01-01

    "Keeping Pace with K-12 Digital Learning" (2014) is the 11th in a series of annual reports that began in 2004 that examine the status of K-12 online education across the country. The report provides an overview of the latest policies, practices, and trends affecting online learning programs across all 50 states. It summarizes that at a…

  12. Processing Advantages of Lexical Bundles: Evidence from Self-Paced Reading and Sentence Recall Tasks

    Science.gov (United States)

    Tremblay, Antoine; Derwing, Bruce; Libben, Gary; Westbury, Chris

    2011-01-01

    This article examines the extent to which lexical bundles (LBs; i.e., frequently recurring strings of words that often span traditional syntactic boundaries) are stored and processed holistically. Three self-paced reading experiments compared sentences containing LBs (e.g., "in the middle of the") and matched control sentence fragments (e.g., "in…

  13. On the pace of fertility decline in sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    David Shapiro

    2017-10-01

    Full Text Available Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa. Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world. Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they are into their fertility transition. Results: The data shows clearly that fertility decline in sub-Saharan Africa, still at a comparatively early stage, has been considerably slower than the earlier declines in Asia, Latin America and the Caribbean, and Northern Africa at comparable stages of the transition, and displays less within-region heterogeneity than the transitions in these other regions. Conclusions: The slower pace of fertility decline in sub-Saharan Africa, in conjunction with the high current fertility levels in the region, means that in the absence of policies seeking to accelerate fertility decline, sub-Saharan Africa will continue to experience rapid population growth that in turn will constrain its development. Contribution: Presentation of data in a novel way (Figures 2‒4, and associated calculations unambiguously demonstrates the slow pace of fertility decline in sub-Saharan Africa compared with other regions of the world.

  14. Pacing and Self-regulation : Important Skills for Talent Development in Endurance Sports

    NARCIS (Netherlands)

    Elferink-Gemser, Marije T.; Hettinga, Florentine J.

    Pacing has been characterized as a multifaceted goal-directed process of decision making in which athletes need to decide how and when to invest their energy during the race, a process essential for optimal performance. Both physiological and psychological characteristics associated with adequate

  15. Children's Use of Self-Paced Slideshows: An Extension of the Video Deficit Effect?

    Science.gov (United States)

    Sage, Kara D.; Baldwin, Dare

    2015-01-01

    Past research has established that children typically learn better from live demonstrations than from two-dimensional (2D) media. In the present set of experiments, we investigated the efficacy of a new 2D learning medium-the self-paced slideshow. A primary goal was to determine whether the "video deficit effect" extended to self-paced…

  16. Financing the Business. PACE Revised. Level 2. Unit 8. Research & Development Series No. 240BB8.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This unit on financing a small business, the eighth in a series of 18 modules, is on the second level of the revised PACE (Program for Acquiring Competence in Entrepreneurship) comprehensive curriculum. Geared to advanced secondary and beginning postsecondary or adult students, the modules provide an opportunity to learn about and try out…

  17. Financing the Business. PACE Revised. Level 3. Unit 8. Research & Development Series No. 240CB8.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This individualized, competency-based unit on financing businesses, the eighth of 18 modules, is on the third level of the revised Program for Acquiring Competence in Entrepreneurship (PACE). Intended for the advanced secondary and postsecondary levels and for adults wanting training or retraining, this unit, together with the other materials at…

  18. Factorial Validity and Gender Invariance of the Physical Activity Enjoyment Scale (PACES) in Older Adolescents

    Science.gov (United States)

    Dunton, Genevieve Fridlund; Tscherne, James; Rodriguez, Daniel

    2009-01-01

    Documented gender differences in physical activity rates during adolescence (Grunbaum et al., 2004) pose the question of whether physical activity enjoyment similarly differs between boys and girls. However, a necessary precursor to research on this topic is that the factor structure of the PACES be equivalent across gender. Although gender…

  19. Sound Effects for Children's Comprehension of Variably-Paced Television Programs.

    Science.gov (United States)

    Calvert, Sandra L.; Scott, M. Catherine

    In this study, children's selective attention to, and comprehension of, variably-paced television programs were examined as a function of sound effects. Sixty-four children, equally distributed by sex and by preschool and fourth grades, were randomly assigned to one of four treatment conditions which crossed two levels of sound effects (presence…

  20. Characterizing the concept of activity pacing as a non-pharmacological intervention in rheumatology care

    DEFF Research Database (Denmark)

    Cuperus, N; Vliet Vlieland, Tpm; Brodin, N

    2016-01-01

    OBJECTIVE: To develop a consensual list of the most important aspects of activity pacing (AP) as an intervention within the context of non-pharmacological rheumatology care. METHOD: An international, multidisciplinary expert panel comprising 60 clinicians and/or healthcare providers experienced i...

  1. The effect of work pace on workload, motor variability and fatigue during simulated light assembly work

    NARCIS (Netherlands)

    Bosch, T.; Mathiassen, S.E.; Visser, B.; Looze, M.D. de; Dieën, J.V. van

    2011-01-01

    This study investigated the effect of work pace on workload, motor variability and fatigue during light assembly work. Upper extremity kinematics and electromyography (EMG) were obtained on a cycle-to-cycle basis for eight participants during two conditions, corresponding to "normal" and "high" work

  2. Pacing Behavior and Tactical Positioning in 500-and 1000-m Short-Track Speed Skating

    NARCIS (Netherlands)

    Noorbergen, Olaf S.; Konings, Marco J.; Micklewright, Dominic; Elferink-Gemser, Marge T.; Hettinga, Florentina J.

    Purpose: To explore pacing behavior and tactical positioning during the shorter 500- and 1000-m short-track competitions. Methods: Lap times and intermediate rankings of elite 500- and 1000-m short-track-skating competitors were collected over the 2012-13 season. First, lap times were analyzed using

  3. Constitutive innate immunity is a component of the pace-of-life syndrome in tropical birds

    NARCIS (Netherlands)

    Tieleman, BI; Williams, JB; Ricklefs, RE; Klasing, KC; Williams, Joseph B.; Ricklefs, Robert E.; Klasing, Kirk C.

    2005-01-01

    We studied the relationship between one component of immune function and basal metabolic rate (BMR), an indicator of the 'pace-of-life syndrome', among 12 tropical bird species and among individuals of the tropical house wren (Troglodytes aedon), to gain insights into functional connections between

  4. Understanding the Cranial Nerves: Evaluation of a Self-Paced Online Module in Optometric Education

    Science.gov (United States)

    Taylor, Daniel Arnett

    2016-01-01

    Among the faculty of Southern College of Optometry in Memphis, Tennessee, it is perceived that optometry students often enter their clinical assignments with poor clinical judgment. To address this, "Understanding the Cranial Nerves"--an online-self paced instructional intervention of approximately two hours' duration--was developed. In…

  5. Classifying running-related injuries based upon etiology, with emphasis on volume and pace

    DEFF Research Database (Denmark)

    Nielsen, R.O.; Nohr, Ellen Aagaard; Rasmussen, Sten

    2013-01-01

    Many researchers acknowledge the importance of "training errors" as the main cause of running-related injuries. The purpose of this clinical commentary is to present a theoretical framework for the assumption that some running-related injuries among rear-foot strikers develop due to rapidly...... changing running volume, while others develop due to rapidly changing running pace....

  6. Atrial pacing as an alternative to supine exercise (SE) in radionuclide ventriculography (RNV)

    International Nuclear Information System (INIS)

    Le Grand, V.; Wells, S.; O'Neil, W.W.; Jenkins, J.; Gross, M.D.; Vogel, R.

    1984-01-01

    Stress RNV is at times of limited value as many patients cannot achieve a sufficient pressure rate product (PRP). Atrial pacing is a noninvasive alternative to SE by bicycle ergometry. A swallowable electrode attached to a flexible wire is positioned in a retroatrial position in the esophagus and when connected to a variable output stimulator, variable rate (120, 140, 160 beats/min) atrial pacing ventriculography (APV) can be performed. RNV is performed in the sitting position at rest and at each pacing stage. APV was compared to SE RNV in 4 patients with coronary artery disease (CAD) and 3 normal volunteers (N). Tolerance to APV was excellent with adequate pacing. All subjects reported a minor sensation of chest burning. No arrhythmias occurred. At maximal APV mean PRP was 174 +- 26. The diastolic volumes in APV fell in all patients. Systolic volumes fell in N but not in CAD to APV. A flat EF response to APV was seen in both N and CAD patients. APV is an alternative to SE RNV although PRP remains low. Volume changes in APV are different than in SE RNV and in the interpretation of the results of APV in CAD, changes in systolic and diastolic volumes may be more important than the response of EF

  7. Vocal cord collapse during phrenic nerve-paced respiration in congenital central hypoventilation syndrome.

    Science.gov (United States)

    Domanski, Mark C; Preciado, Diego A

    2012-01-01

    Phrenic nerve pacing can be used to treat congenital central hypoventilation syndrome (CCHS). We report how the lack of normal vocal cord tone during phrenic paced respiration can result in passive vocal cord collapse and produce obstructive symptoms. We describe a case of passive vocal cord collapse during phrenic nerve paced respiration in a patient with CCHS. As far as we know, this is the first report of this etiology of airway obstruction. The patient, a 7-year-old with CCHS and normal waking vocal cord movement, continued to require nightly continuous positive airway pressure (CPAP) despite successful utilization of phrenic nerve pacers. On direct laryngoscopy, the patient's larynx was observed while the diaphragmatic pacers were sequentially engaged. No abnormal vocal cord stimulation was witnessed during engaging of either phrenic nerve stimulator. However, the lack of normal inspiratory vocal cord abduction during phrenic nerve-paced respiration resulted in vocal cord collapse and partial obstruction due to passive adduction of the vocal cords through the Bernoulli effect. Bilateral phrenic nerve stimulation resulted in more vocal cord collapse than unilateral stimulation. The lack of vocal cord abduction on inspiration presents a limit to phrenic nerve pacers.

  8. Causes and implications of the slow pace of technology transfer and ...

    African Journals Online (AJOL)

    The causes of slow pace of technology transfer and adoption were identified to include ineffectiveness of extension delivery system, lack of adequate liaison between extension and research, lack of trained personnel both in quantity and quality, inadequate financial support, complexity of the new technology, incompatibility, ...

  9. Investigating the Effects of Concurrent Performance of Physical and Cognitive Demanding Task in Paced Assembly Lines

    Directory of Open Access Journals (Sweden)

    Shakil Ahmed Shaikh

    2013-07-01

    Full Text Available The study was undertaken to investigate the effects of pacing on aspects of performance at an assembly task and on the operators' responses related to work behaviour, perceived workload and perceived stress. A particular objective of the study was to investigate whether physical and cognitive demands may interact in their influences on these effects. An assembly task was simulated in the laboratory and the level of pacing imposed, work height and memory load within the task were all varied. The results showed that the type of pacing commonly imposed (as is common with a lean manufacturing Takt time system in industry can significantly affect both performance and perceived workload and stress. Physical demands (through work height affecting posture and mental demand (through memory load were also found to have significant effects, as would be expected from the many studies of these in the literature. More importantly, some interactions were found between pacing and work height in their effects on quality of assembly and the operator's own rating of performance, and between work height and memory load in their effects on errors. These findings will need to be taken into account by companies when implementing Takt time systems.

  10. Increased diagnostic contribution of heart rate variability at 0.1Hz paced breathing

    Czech Academy of Sciences Publication Activity Database

    Jurák, Pavel; Halámek, Josef; Somers, V. K.; Nykodým, J.; Leinveber, P.; Fráňa, P.; Eisenberger, M.; Kára, T.

    2005-01-01

    Roč. 4, č. 1 (2005), s. 95 [World Congress on Heart Disease - New Trends in Research, Diagnosis and Treatment /12./. 16.07.2005-19.07.2005, Vancouver] R&D Projects: GA ČR(CZ) GA102/05/0402 Keywords : paced breathing * HRV * ICD Subject RIV: FS - Medical Facilities ; Equipment

  11. Effect of "U-Pace" Instruction on Academic Success, Learning, and Perceptions in Younger and Older Undergraduates

    Science.gov (United States)

    Fleming, Raymond; Barth, Dylan; Weber, Nicole; Pedrick, Laura E.; Kienzler, Sarah E.; Reddy, Diane M.

    2018-01-01

    A randomized controlled trial was conducted to determine the efficacy of "U-Pace" instruction for older undergraduates, ages 25 and older, and younger undergraduates, ages 18 to 24. Additionally, change in learner perceptions across the semester, an outcome not reported in the literature on "U-Pace" instruction, was…

  12. Planning the Marketing Strategy. PACE Revised. Level 1. Unit 6. Research & Development Series No. 240AB6.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on planning a marketing strategy, the sixth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  13. Pacing Profiles in Competitive Track Races: Regulation of Exercise Intensity is related to Cognitive Ability

    Directory of Open Access Journals (Sweden)

    Debbie Van Biesen

    2016-12-01

    Full Text Available Pacing has been defined as the goal-directed regulation of exercise intensity over an exercise bout, in which athletes need to decide how and when to invest their energy. The purpose of this study was to explore if the regulation of exercise intensity during competitive track races is different between runners with and without intellectual impairment, which is characterized by significant limitations in intellectual functioning (IQ≤75 and adaptive behavioral deficits, diagnosed before the age of 18. The samples included elite runners with intellectual impairment (N= 36 and a comparison group of world class runners without impairment (N= 39, of which 47 were 400m runners (all male and 28 were 1500m-runners (15 male and 13 female. Pacing was analysed by means of 100m split times (for 400m races and 200m split times (for 1500m races. Based on the split times, the average velocity was calculated for four segments of the races. Velocity fluctuations were defined as the differences in velocity between consecutive race segments. A mixed model ANOVA revealed significant differences in pacing profiles between runners with and without intellectual impairment (p<.05. Maximal velocity of elite 400m runners with intellectual impairment in the first race segment (7.9 ± 0.3 m/s was well below the top-velocity reached by world level 400m runners without intellectual impairment (8.9 ±0.2 m/s, and their overall pace was slower (F=120.7, p<.05. In addition, both groups followed a different pacing profile and inter-individual differences in pacing profiles were larger, with differences most pronounced for 1500m races. Whereas male 1500m-runners without intellectual impairment reached a high velocity in the first 100m (7.2±0.1 m/s, slowly decelerated in the second race segment (-0.6±0.1 m/s, and finished with an end sprint (+0.9±0.1 m/s; the 1500m runners with intellectual impairment started slower (6.1±0.3 m/s, accelerated in the second segment (+ 0.2±0

  14. Lessons in Commercial PACE Leadership: The Path from Legislation to Launch

    Energy Technology Data Exchange (ETDEWEB)

    Leventis, G; Schwartz, LC; Kramer, C; Deason, J

    2018-02-27

    Nonresidential buildings are responsible for over a quarter of primary energy consumption in the United States. Efficiency improvements in these buildings could result in significant energy and utility bill savings. To unlock those potential savings, a number of market barriers to energy efficiency must be addressed. Commercial Property Assessed Clean Energy (C-PACE) financing programs can help overcome several of these barriers with minimal investment from state and local governments. With programs established or under development in 22 states, and at least $521 million in investments so far, other state and local governments are interested in bringing the benefits of C-PACE to their jurisdictions. Lessons in Commercial PACE Leadership: The Path from Legislation to Launch, aims to fast track the set-up of C-PACE programs for state and local governments by capturing the lessons learned from leaders. The report examines the list of potential program design options and important decision points in setting up a C-PACE program, tradeoffs for available options, and experiences of stakeholders that have gone through (or are going through) the process. C-PACE uses a voluntary special property assessment to facilitate energy and other improvements in commercial buildings. For example: - Long financing terms under C-PACE can produce cash flow-positive -- projects to help overcome a focus on short paybacks. - Payment obligations can transfer to subsequent owners, mitigating concern about investing in improvements for a building that may be sold before the return on the investment is fully realized. - 100% of both hard and soft costs can be financed. To capture the benefits of C-PACE financing, state and local governments must navigate numerous decision points and engage with stakeholders to set-up or join a program. Researchers interviewed experts (including state and local sponsors, program administrators, capital providers and industry experts) on their lessons learned and

  15. The downside of downtime: The prevalence and work pacing consequences of idle time at work.

    Science.gov (United States)

    Brodsky, Andrew; Amabile, Teresa M

    2018-05-01

    Although both media commentary and academic research have focused much attention on the dilemma of employees being too busy, this paper presents evidence of the opposite phenomenon, in which employees do not have enough work to fill their time and are left with hours of meaningless idle time each week. We conducted six studies that examine the prevalence and work pacing consequences of involuntary idle time. In a nationally representative cross-occupational survey (Study 1), we found that idle time occurs frequently across all occupational categories; we estimate that employers in the United States pay roughly $100 billion in wages for time that employees spend idle. Studies 2a-3b experimentally demonstrate that there are also collateral consequences of idle time; when workers expect idle time following a task, their work pace declines and their task completion time increases. This decline reverses the well-documented deadline effect, producing a deadtime effect, whereby workers slow down as a task progresses. Our analyses of work pace patterns provide evidence for a time discounting mechanism: workers discount idle time when it is relatively distant, but act to avoid it increasingly as it becomes more proximate. Finally, Study 4 demonstrates that the expectation of being able to engage in leisure activities during posttask free time (e.g., surfing the Internet) can mitigate the collateral work pace losses due to idle time. Through examination and discussion of the effects of idle time at work, we broaden theory on work pacing. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. Impact of pacing on systemic ventricular function in L-transposition of the great arteries.

    Science.gov (United States)

    Hofferberth, Sophie C; Alexander, Mark E; Mah, Douglas Y; Bautista-Hernandez, Victor; del Nido, Pedro J; Fynn-Thompson, Francis

    2016-01-01

    To assess the impact of univentricular versus biventricular pacing (BiVP) on systemic ventricular function in patients with congenitally corrected transposition of the great arteries (ccTGA). We performed a retrospective review of all patients with a diagnosis of ccTGA who underwent pacemaker insertion. From 1993 to 2014, 53 patients were identified from the cardiology database and surgical records. Overall mortality was 7.5% (n = 4). One patient required transplantation and 3 late deaths occurred secondary to end-stage heart failure. Median follow-up was 3.7 years (range, 4 days to 22.5 years). Twenty-five (47%) underwent univentricular pacing only, of these, 8 (32%) developed significant systemic ventricular dysfunction. Twenty-eight (53%) received BiVP, 17 (26%) were upgraded from a dual-chamber system, 11 (21%) received primary BiVP. Fourteen (82%) of the 17 undergoing secondary BiVP demonstrated systemic ventricular dysfunction at the time of pacer upgrade, with 7 (50%) demonstrating improved systemic ventricular function after pacemaker upgrade. Overall, 42 (79%) patients underwent univentricular pacing, with 22 (52%) developing significant systemic ventricular dysfunction. In contrast, the 11 (21%) who received primary BiVP had preserved systemic ventricular function at latest follow-up. Late-onset systemic ventricular dysfunction is a major complication associated with the use of univentricular pacing in patients with ccTGA. All patients with ccTGA who develop heart block should undergo primary biventricular pacing, as this prevents late systemic ventricular dysfunction. Preemptive placement of BiVP leads at the time of anatomical repair or other permanent palliative procedure will facilitate subsequent BiVP should heart block develop. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  17. Even between-lap pacing despite high within-lap variation during mountain biking.

    Science.gov (United States)

    Martin, Louise; Lambeth-Mansell, Anneliese; Beretta-Azevedo, Liane; Holmes, Lucy A; Wright, Rachel; St Clair Gibson, Alan

    2012-09-01

    Given the paucity of research on pacing strategies during competitive events, this study examined changes in dynamic high-resolution performance parameters to analyze pacing profiles during a multiple-lap mountain-bike race over variable terrain. A global-positioning-system (GPS) unit (Garmin, Edge 305, USA) recorded velocity (m/s), distance (m), elevation (m), and heart rate at 1 Hz from 6 mountain-bike riders (mean±SD age=27.2±5.0 y, stature=176.8±8.1 cm, mass=76.3±11.7 kg, VO2max=55.1±6.0 mL·kg(-1)·min1) competing in a multilap race. Lap-by-lap (interlap) pacing was analyzed using a 1-way ANOVA for mean time and mean velocity. Velocity data were averaged every 100 m and plotted against race distance and elevation to observe the presence of intralap variation. There was no significant difference in lap times (P=.99) or lap velocity (P=.65) across the 5 laps. Within each lap, a high degree of oscillation in velocity was observed, which broadly reflected changes in terrain, but high-resolution data demonstrated additional nonmonotonic variation not related to terrain. Participants adopted an even pace strategy across the 5 laps despite rapid adjustments in velocity during each lap. While topographical and technical variations of the course accounted for some of the variability in velocity, the additional rapid adjustments in velocity may be associated with dynamic regulation of self-paced exercise.

  18. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    International Nuclear Information System (INIS)

    Karlstrom, L.; Kelly, K.A.

    1989-01-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction

  19. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    Energy Technology Data Exchange (ETDEWEB)

    Karlstrom, L.; Kelly, K.A. (Mayo Clinic, Rochester, MN (USA))

    1989-11-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction.

  20. Prevalence of conduction delay of the right atrium in patients with SSS: implications for pacing site selection.

    Science.gov (United States)

    Verlato, Roberto; Zanon, Francesco; Bertaglia, Emanuele; Turrini, Pietro; Baccillieri, Maria Stella; Baracca, Enrico; Bongiorni, Maria Grazia; Zampiero, Aldo; Zonzin, Pietro; Pascotto, Pietro; Venturini, Diego; Corbucci, Giorgio

    2007-09-01

    To evaluate the prevalence of severe right atrial conduction delay in patients with sinus node dysfunction (SND) and atrial fibrillation (AF) and the effects of pacing in the right atrial appendage (RAA) and in the inter-atrial septum (IAS). Forty-two patients (15 male, 72 +/- 7 years) underwent electrophysiologic study to measure the difference between the conduction time from RAA to coronary sinus ostium during stimulation at 600 ms and after extrastimulus (DeltaCTos). Patients were classified as group A if DeltaCTos > 60 ms and group B if IAS pacing and algorithms ON/OFF. Fifteen patients (36%, group A) had DeltaCTos = 76 +/- 11 ms and 27 patients (64%, group B) had DeltaCTos = 36 +/- 20 ms. Twenty-two patients were paced at the RAA and 20 at the IAS. During the study, no AF recurrences were reported in 11 of 42 (26%) patients, independently of RAA or IAS pacing. Patients from group A and RAA pacing had 0.79 +/- 0.81 episodes of AF/day during DDD, which increased to 1.52 +/- 1.41 episodes of AF/day during DDDR + Alg (P = 0.046). Those with IAS pacing had 0.5 +/- 0.24 episodes of AF/day during DDD, which decreased to 0.06 +/- 0.08 episodes of AF/day during DDDR + Alg (P = 0.06). In group B, no differences were reported between pacing sites and pacing modes. Severe right atrial conduction delay is present in one-third of patients with SND and AF: continuous pacing at the IAS is superior to RAA for AF recurrences. In patients without severe conduction delay, no differences between pacing site or mode were observed.

  1. Variation in turbidity with precipitation and flow in a regulated river system – river Göta Älv, SW Sweden

    Directory of Open Access Journals (Sweden)

    G. Göransson

    2013-07-01

    Full Text Available The turbidity variation in time and space is investigated in the downstream stretch of the river Göta Älv in Sweden. The river is heavily regulated and carries the discharge from the largest fresh water lake in Sweden, Lake Vänern, to the outflow point in Göteborg Harbour on the Swedish west coast. The river is an important waterway and serves as a fresh-water supply for 700 000 users. Turbidity is utilised as a water quality indicator to ensure sufficient quality of the intake water to the treatment plant. The overall objective of the study was to investigate the influence of rainfall, surface runoff, and river water flow on the temporal and spatial variability of the turbidity in the regulated river system by employing statistical analysis of an extensive data set. A six year long time series of daily mean values on precipitation, discharge, and turbidity from six stations along the river were examined primarily through linear correlation and regression analysis, combined with nonparametric tests and analysis of variance. The analyses were performed on annual, monthly, and daily bases, establishing temporal patterns and dependences, including; seasonal changes, impacts from extreme events, influences from tributaries, and the spatial variation along the river. The results showed that there is no simple relationship between discharge, precipitation, and turbidity, mainly due to the complexity of the runoff process, the regulation of the river, and the effects of Lake Vänern and its large catchment area. For the river Göta Älv, significant, positive correlations between turbidity, discharge, and precipitation could only be found during periods with high flow combined with heavy rainfall. Local precipitation does not seem to have any significant impact on the discharge in the main river, which is primarily governed by precipitation at catchment scale. The discharge from Lake Vänern determines the base level for the turbidity in the river

  2. Scenarios catalog for the graphical console for analysis of severe accidents visualization of OEs, NAEs and calculation of source term of the NPP-LV

    International Nuclear Information System (INIS)

    Sandoval V, S.; Mendoza R, M. E.; Tijerina S, F.; Garcia C, T.

    2016-09-01

    A nuclear power plant is operated at all times within the design criteria of structures, systems and components, and according to the operation technical specifications. For different areas of work of a nuclear power plant is necessary to carry out practices in which is useful to have the prediction of the thermo-hydraulic and radiological progression of scenarios that imply exceeding that design bases, even reaching the damage of the fuel in different degree. During the exercises and drills of the External Plan of Emergency Response, the projection of doses is done to exercise the different tasks of the plan. To make the projection of doses is required to have the radiological source term of the scenario on which is practiced. Because of this, was identified the convenience of having a catalog of scenarios for which the radiological source term was calculated. In 2004, a first version of the catalog was produced for a power of 2027 MW, and in 2011 the catalog was updated for extended power conditions, 2317 MW. Both versions were made using the severe accident simulator MAAP-3B. That catalog consists of a form and an optical storage device. The form contains tables and figures in which the characteristics of the scenario to be practiced are searched and the electronic files of the corresponding radiological source term are located in the storage device. Due to the recent development of the graphical console for analysis of severe accidents, visualization of OEs, NAEs and calculation of the source term for the nuclear power plant of Laguna Verde (NPP-LV) CoGrAAS, the catalog printed was replaced by an electronic catalog for the CoGrAAS. The new catalog retains the philosophy of the previous catalog, constituted by a wide collection of scenarios that involve different circumstances and phenomena, that can be used to practice different tasks during training exercises or simulacrums, and combined with the following advantages: the scenario selection is made from an

  3. Challenge of engaging all students via self-paced interactive electronic learning tutorials for introductory physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-06-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar introductory physics courses and then propose a framework for helping students engage effectively with the learning tools. The tutorials were developed via research in physics education and were found to be effective for a diverse group of introductory physics students in one-on-one implementation. Instructors encouraged the use of these tools in a self-paced learning environment by telling students that they would be helpful for solving the assigned homework problems and that the underlying physics principles in the tutorial problems would be similar to those in the in-class quizzes (which we call paired problems). We find that many students in the courses in which these interactive electronic learning tutorials were assigned as a self-study tool performed poorly on the paired problems. In contrast, a majority of student volunteers in one-on-one implementation greatly benefited from the tutorials and performed well on the paired problems. The significantly lower overall performance on paired problems administered as an in-class quiz compared to the performance of student volunteers who used the research-based tutorials in one-on-one implementation suggests that many students enrolled in introductory physics courses did not effectively engage with the tutorials outside of class and may have only used them superficially. The findings suggest that many students in need of out-of-class remediation via self-paced learning tools may have difficulty motivating themselves and may lack the self-regulation and time-management skills to engage effectively with tools specially designed to help them learn at their own pace. We

  4. Challenge of engaging all students via self-paced interactive electronic learning tutorials for introductory physics

    Directory of Open Access Journals (Sweden)

    Seth DeVore

    2017-05-01

    Full Text Available As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar introductory physics courses and then propose a framework for helping students engage effectively with the learning tools. The tutorials were developed via research in physics education and were found to be effective for a diverse group of introductory physics students in one-on-one implementation. Instructors encouraged the use of these tools in a self-paced learning environment by telling students that they would be helpful for solving the assigned homework problems and that the underlying physics principles in the tutorial problems would be similar to those in the in-class quizzes (which we call paired problems. We find that many students in the courses in which these interactive electronic learning tutorials were assigned as a self-study tool performed poorly on the paired problems. In contrast, a majority of student volunteers in one-on-one implementation greatly benefited from the tutorials and performed well on the paired problems. The significantly lower overall performance on paired problems administered as an in-class quiz compared to the performance of student volunteers who used the research-based tutorials in one-on-one implementation suggests that many students enrolled in introductory physics courses did not effectively engage with the tutorials outside of class and may have only used them superficially. The findings suggest that many students in need of out-of-class remediation via self-paced learning tools may have difficulty motivating themselves and may lack the self-regulation and time-management skills to engage effectively with tools specially designed to help them learn at their

  5. Energy levels, oscillator strengths, line strengths, and transition probabilities in Si-like ions of La XLIII, Er LIV, Tm LV, and Yb LVI

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhan-Bin, E-mail: chenzb008@qq.com [College of Science, National University of Defense Technology, Changsha, Hunan 410073 (China); Ma, Kun [School of Information Engineering, Huangshan University, Huangshan 245041 (China); Wang, Hong-Jian [Chongqing Key Laboratory for Design and Control of Manufacturing Equipment, Chongqing Technology and Business University, Chongqing 40067 (China); Wang, Kai, E-mail: wangkai@hbu.edu.cn [Hebei Key Lab of Optic-electronic Information and Materials, The College of Physics Science and Technology, Hebei University, Baoding 071002 (China); Liu, Xiao-Bin [Department of Physics, Tianshui Normal University, Tianshui 741001 (China); Zeng, Jiao-Long [College of Science, National University of Defense Technology, Changsha, Hunan 410073 (China)

    2017-01-15

    Detailed calculations using the multi-configuration Dirac–Fock (MCDF) method are carried out for the lowest 64 fine-structure levels of the 3s{sup 2}3p{sup 2}, 3s{sup 2}3p3d, 3s3p{sup 3}, 3s3p{sup 2}3d, 3s{sup 2}3d{sup 2}, and 3p{sup 4} configurations in Si-like ions of La XLIII, Er LIV, Tm LV, and Yb LVI. Energies, oscillator strengths, wavelengths, line strengths, and radiative electric dipole transition rates are given for all ions. A parallel calculation using the many-body perturbation theory (MBPT) method is also carried out to assess the present energy levels accuracy. Comparisons are performed between these two sets of energy levels, as well as with other available results, showing that they are in good agreement with each other within 0.5%. These high accuracy results can be used to the modeling and the interpretation of astrophysical objects and fusion plasmas. - Highlights: • Energy levels and E1 transition rates of Si-like ions are presented. • Breit interaction and Quantum Electrodynamics effects are discussed. • Present results should be useful in the astrophysical application and plasma modeling.

  6. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  7. Value of the New Spline QTc Formula in Adjusting for Pacing-Induced Changes in Heart Rate

    Directory of Open Access Journals (Sweden)

    Hirmand Nouraei

    2018-01-01

    Full Text Available Aims. To determine whether a new QTc calculation based on a Spline fit model derived and validated from a large population remained stable in the same individual across a range of heart rates (HRs. Second, to determine whether this formula incorporating QRS duration can be of value in QT measurement, compared to direct measurement of the JT interval, during ventricular pacing. Methods. Individuals (N=30; 14 males aged 51.9 ± 14.3 years were paced with decremental atrial followed by decremental ventricular pacing. Results. The new QTc changed minimally with shorter RR intervals, poorly fit even a linear relationship, and did not fit a second-order polynomial. In contrast, the Bazett formula (QTcBZT showed a steep and marked increase in QTc with shorter RR intervals. For atrial pacing data, QTcBZT was fit best by a second-order polynomial and demonstrated a dramatic increase in QTc with progressively shorter RR intervals. For ventricular pacing, the new QTc minus QRS duration did not meaningfully change with HR in contrast to the HR dependency of QTcBZT and JT interval. Conclusion. The new QT correction formula is minimally impacted by HR acceleration induced by atrial or ventricular pacing. The Spline QTc minus QRS duration is an excellent method to estimate QTc in ventricular paced complexes.

  8. A projection-adapted cross entropy (PACE) method for transmission network planning

    Energy Technology Data Exchange (ETDEWEB)

    Eshragh, Ali; Filar, Jerzy [University of South Australia, School of Mathematics and Statistics, Mawson Lakes, SA (Australia); Nazar, Asef [University of South Australia, Institute for Sustainable Systems Technologies, School of Mathematics and Statistics, Mawson Lakes, SA (Australia)

    2011-06-15

    In this paper, we propose an adaptation of the cross entropy (CE) method called projection-adapted CE (PACE) to solve a transmission expansion problem that arises in management of national and provincial electricity grids. The aim of the problem is to find an expansion policy that is both economical and operational from the technical perspective. Often, the transmission network expansion problem is mathematically formulated as a mixed integer nonlinear program that is very challenging algorithmically. The challenge originates from the fact that a global optimum should be found despite the presence, of possibly a huge number, of local optima. The PACE method shows promise in solving global optimization problems regardless of continuity or other assumptions. In our approach, we sample the integer variables using the CE mechanism, and solve LPs to obtain matching continuous variables. Numerical results, on selected test systems, demonstrate the potential of this approach. (orig.)

  9. Towards Development of a 3-State Self-Paced Brain-Computer Interface

    Directory of Open Access Journals (Sweden)

    Ali Bashashati

    2007-01-01

    the presence of a right- or a left-hand movement and the second classifies the detected movement as a right or a left one. In an offline analysis of the EEG data collected from four able-bodied individuals, the 3-state brain-computer interface shows a comparable performance with a 2-state system and significant performance improvement if used as a 2-state BCI, that is, in detecting the presence of a right- or a left-hand movement (regardless of the type of movement. It has an average true positive rate of 37.5% and 42.8% (at false positives rate of 1% in detecting right- and left-hand extensions, respectively, in the context of a 3-state self-paced BCI and average detection rate of 58.1% (at false positive rate of 1% in the context of a 2-state self-paced BCI.

  10. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  11. DiPALS: Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis - a randomised controlled trial.

    Science.gov (United States)

    McDermott, Christopher J; Bradburn, Mike J; Maguire, Chin; Cooper, Cindy L; Baird, Wendy O; Baxter, Susan K; Cohen, Judith; Cantrill, Hannah; Dixon, Simon; Ackroyd, Roger; Baudouin, Simon; Bentley, Andrew; Berrisford, Richard; Bianchi, Stephen; Bourke, Stephen C; Darlison, Roy; Ealing, John; Elliott, Mark; Fitzgerald, Patrick; Galloway, Simon; Hamdalla, Hisham; Hanemann, C Oliver; Hughes, Philip; Imam, Ibrahim; Karat, Dayalan; Leek, Roger; Maynard, Nick; Orrell, Richard W; Sarela, Abeezar; Stradling, John; Talbot, Kevin; Taylor, Lyn; Turner, Martin; Simonds, Anita K; Williams, Tim; Wedzicha, Wisia; Young, Carolyn; Shaw, Pamela J

    2016-06-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease resulting in death, usually from respiratory failure, within 2-3 years of symptom onset. Non-invasive ventilation (NIV) is a treatment that when given to patients in respiratory failure leads to improved survival and quality of life. Diaphragm pacing (DP), using the NeuRx/4(®) diaphragm pacing system (DPS)™ (Synapse Biomedical, Oberlin, OH, USA), is a new technique that may offer additional or alternative benefits to patients with ALS who are in respiratory failure. The Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis (DiPALS) trial evaluated the effect of DP on survival over the study duration in patients with ALS with respiratory failure. The DiPALS trial was a multicentre, parallel-group, open-label, randomised controlled trial incorporating health economic analyses and a qualitative longitudinal substudy. Eligible participants had a diagnosis of ALS (ALS laboratory-supported probable, clinically probable or clinically definite according to the World Federation of Neurology revised El Escorial criteria), had been stabilised on riluzole for 30 days, were aged ≥ 18 years and were in respiratory failure. We planned to recruit 108 patients from seven UK-based specialist ALS or respiratory centres. Allocation was performed using 1 : 1 non-deterministic minimisation. Participants were randomised to either standard care (NIV alone) or standard care (NIV) plus DP using the NeuRX/4 DPS. The primary outcome was overall survival, defined as the time from randomisation to death from any cause. Secondary outcomes were patient quality of life [assessed by European Quality of Life-5 Dimensions, three levels (EQ-5D-3L), Short Form questionnaire-36 items and Sleep Apnoea Quality of Life Index questionnaire]; carer quality of life (EQ-5D-3L and Caregiver Burden Inventory); cost-utility analysis and health-care resource use; tolerability and adverse events. Acceptability and attitudes to

  12. Effects of self-paced interval and continuous training on health markers in women

    DEFF Research Database (Denmark)

    Connolly, Luke J; Bailey, Stephen J; Krustrup, Peter

    2017-01-01

    PURPOSE: To compare the effects of self-paced high-intensity interval and continuous cycle training on health markers in premenopausal women. METHODS: Forty-five inactive females were randomised to a high-intensity interval training (HIIT; n = 15), continuous training (CT; n = 15) or an inactive...... control (CON; n = 15) group. HIIT performed 5 × 5 min sets comprising repetitions of 30-s low-, 20-s moderate- and 10-s high-intensity cycling with 2 min rest between sets. CT completed 50 min of continuous cycling. Training was completed self-paced, 3 times weekly for 12 weeks. RESULTS: Peak oxygen...... uptake (16 ± 8 and 21 ± 12%), resting heart rate (HR) (-5 ± 9 and -4 ± 7 bpm) and visual and verbal learning improved following HIIT and CT compared to CON (P HIIT (P 

  13. Classifying running-related injuries based upon etiology, with emphasis on volume and pace

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Oestergaard; Nohr, Ellen Aagaard; Rasmussen, Sten

    2013-01-01

    BACKGROUND AND PURPOSE: Many researchers acknowledge the importance of "training errors" as the main cause of running-related injuries. The purpose of this clinical commentary is to present a theoretical framework for the assumption that some running-related injuries among rear-foot strikers...... of patellofemoral pain syndrome, iliotibial band syndrome, and patellar tendinopathy, while change in running pace may be associated with the development of achilles tendinopathy, gastrocnemius injuries, and plantar fasciitis. DISCUSSIONRELATION TO CLINICAL PRACTICE: If this assertion is correct, bias may...... develop due to rapidly changing running volume, while others develop due to rapidly changing running pace. DESCRIPTION OF TOPIC WITH RELATED EVIDENCE: Evidence from clinical and experimental studies is presented to support the assertion that rapid change in running volume may lead to the development...

  14. Classification of PolSAR Images Using Multilayer Autoencoders and a Self-Paced Learning Approach

    Directory of Open Access Journals (Sweden)

    Wenshuai Chen

    2018-01-01

    Full Text Available In this paper, a novel polarimetric synthetic aperture radar (PolSAR image classification method based on multilayer autoencoders and self-paced learning (SPL is proposed. The multilayer autoencoders network is used to learn the features, which convert raw data into more abstract expressions. Then, softmax regression is applied to produce the predicted probability distributions over all the classes of each pixel. When we optimize the multilayer autoencoders network, self-paced learning is used to accelerate the learning convergence and achieve a stronger generalization capability. Under this learning paradigm, the network learns the easier samples first and gradually involves more difficult samples in the training process. The proposed method achieves the overall classification accuracies of 94.73%, 94.82% and 78.12% on the Flevoland dataset from AIRSAR, Flevoland dataset from RADARSAT-2 and Yellow River delta dataset, respectively. Such results are comparable with other state-of-the-art methods.

  15. The downside of downtime: The prevalence and work pacing consequences of idle time at work

    OpenAIRE

    Brodsky, Andrew; Amabile, Teresa M.

    2018-01-01

    Although both media commentary and academic research have focused much attention on the dilemma of employees being too busy, this paper presents evidence of the opposite phenomenon, in which employees do not have enough work to fill their time and are left with hours of meaningless idle time each week. We conducted six studies that examine the prevalence and work pacing consequences of involuntary idle time. In a nationally representative cross-occupational survey (Study 1), we found that idl...

  16. The impact of the perception of rhythmic music on self-paced oscillatory movements.

    Science.gov (United States)

    Peckel, Mathieu; Pozzo, Thierry; Bigand, Emmanuel

    2014-01-01

    Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping) while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20 s before a 2 s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced) while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with the task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e., motor/perceptual resonance). In general, our results give support to the notion that rhythmic music is processed in a motoric

  17. Basal metabolism in tropical birds: Latitude, altitude, and the 'pace of life'

    OpenAIRE

    Londoño, GA; Chappell, MA; Castañeda, MDR; Jankowski, JE; Robinson, SK

    2015-01-01

    © 2014 The Authors. Life history varies across latitudes, with the 'pace of life' being 'slower' in tropical regions. Because life history is coupled to energy metabolism via allocation tradeoffs and links between performance capacity and energy use, low metabolic intensity is expected in tropical animals. Low metabolism has been reported for lowland tropical birds, but it is unclear if this is due to 'slow' life history or to a warm, stable environment. We measured basal metabolic rates (BMR...

  18. Potential Effect of Physical Activity Calorie Equivalent (PACE) Labeling on Adult Fast Food Ordering and Exercise

    OpenAIRE

    Antonelli, Ray; Viera, Anthony J.

    2015-01-01

    Introduction Numeric calorie content labels show limited efficacy in reducing the number of calories ordered from fast food meals. Physical activity calorie equivalent (PACE) labels are an alternative that may reduce the number of calories ordered in fast food meals while encouraging patrons to exercise. Methods A total of 1000 adults from 47 US states were randomly assigned via internet survey to one of four generic fast food menus: no label, calories only, calories + minutes, or calories + ...

  19. First implantation of selective his bundle pacing in Colombia. Report of two cases

    International Nuclear Information System (INIS)

    Velasquez, Jorge E; Duque, Mauricio; Marin V, Jorge E; Aristizabal, Julian M; Medina, Luis E; Gonzalez, Edgardo; Duque, Laura; Uribe, William

    2010-01-01

    Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomyopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

  20. Effect of recovery interventions on cycling performance and pacing strategy in the heat.

    Science.gov (United States)

    De Pauw, Kevin; Roelands, Bart; Vanparijs, Jef; Meeusen, Romain

    2014-03-01

    To determine the effect of active recovery (AR), passive rest (PR), and cold-water immersion (CWI) after 90 min of intensive cycling on a subsequent 12-min time trial (TT2) and the applied pacing strategy in TT2. After a maximal test and familiarization trial, 9 trained male subjects (age 22 ± 3 y, VO2max 62.1 ± 5.3 mL · min-1 · kg-1) performed 3 experimental trials in the heat (30°C). Each trial consisted of 2 exercise tasks separated by 1 h. The first was a 60-min constant-load trial at 55% of the maximal power output followed by a 30-min time trial (TT1). The second comprised a 12-min simulated time trial (TT2). After TT1, AR, PR, or CWI was applied for 15 min. No significant TT2 performance differences were observed, but a 1-sample t test (within each condition) revealed different pacing strategies during TT2. CWI resulted in an even pacing strategy, while AR and PR resulted in a gradual decline of power output after the onset of TT2 (P ≤ .046). During recovery, AR and CWI showed a trend toward faster blood lactate ([BLa]) removal, but during TT2 significantly higher [BLa] was only observed after CWI compared with PR (P = .011). The pacing strategy during subsequent cycling performance in the heat is influenced by the application of different postexercise recovery interventions. Although power was not significantly altered between groups, CWI enabled a differently shaped power profile, likely due to decreased thermal strain.

  1. Diagnostic value of transesophageal atrial pacing myocardial perfusion imaging in coronary artery disease

    International Nuclear Information System (INIS)

    Jia Yongping; Li Zhiling; Li Yunqian

    1994-01-01

    Transesophageal atrial pacing (TAP) SPECT myocardial perfusion imaging (MPI) with 99m Tc-MIBI was performed in 46 patients with coronary artery disease (CAD) and 15 normal subjects. The results were compared with exercise SPECT MPI. The results showed that the sensitivity and specificity of TAP SPECT to evaluate CAD were 86,96% and 93.33%. TAP SPECT MPI had a significant correlation with exercise SPECT MPI to detect ischemic segment of CAD (r = 0.95)

  2. Financial audit of antitachycardia pacing for the control of recurrent supraventricular tachycardia.

    Science.gov (United States)

    Griffith, M J; Bexton, R S; McComb, J M

    1993-03-01

    To assess the financial implications of antitachycardia pacing in patients with frequent supraventricular tachycardia. Intertach pacemakers were implanted in 25 patients (mean age 47 years, five men): 22 had atrioventricular nodal reentry tachycardia. The patients had failed a mean of 4.9 (range zero to eight) drugs and had been admitted to hospital 3.7 (zero to 31) times over a symptomatic period of 13.9 years (two months to 54 years). The mean admission time for implantation was 2.8 (two to seven) days. One patient with Wolff-Parkinson-White syndrome subsequently underwent surgery. Infection occurred in two patients, and pain over the pacemaker required its resiting in two. Two patients have had one admission each for tachycardia. Six patients remain on anti-arrhythmic drugs. Costs were calculated including value added tax, capital charges, and allocated overheads. The cost a year before pacing was 1174 pounds including drug costs, clinic visits, and hospital admissions. The mean cost of pacemaker implantation was 3364.22 pounds, including the pacemaker and lead, admission and procedure, readmissions and first pacing check. Subsequent annual follow up cost was 73.72 pounds including annual clinic visits and drug costs. The cost of pacing is 4241 pounds whereas medical management costs 7044 pounds assuming pacemaker life of six years: with a 10 year life the cost is 4537 pounds compared with 11,740 pounds: with a 12 year life the cost is 4685 pounds compared with 14,088 pounds. The excess cost of implantation of an antitachycardia pacemaker is minimal in patients with frequent supraventricular tachycardia despite drug treatment and is justified by excellent control of symptoms and reduction of drug use and hospital admissions.

  3. Pacing Strategy, Muscle Fatigue, and Technique in 1500-m Speed-Skating and Cycling Time Trials.

    Science.gov (United States)

    Stoter, Inge K; MacIntosh, Brian R; Fletcher, Jared R; Pootz, Spencer; Zijdewind, Inge; Hettinga, Florentina J

    2016-04-01

    To evaluate pacing behavior and peripheral and central contributions to muscle fatigue in 1500-m speed-skating and cycling time trials when a faster or slower start is instructed. Nine speed skaters and 9 cyclists, all competing at regional or national level, performed two 1500-m time trials in their sport. Athletes were instructed to start faster than usual in 1 trial and slower in the other. Mean velocity was measured per 100 m. Blood lactate concentrations were measured. Maximal voluntary contraction (MVC), voluntary activation (VA), and potentiated twitch (PT) of the quadriceps muscles were measured to estimate central and peripheral contributions to muscle fatigue. In speed skating, knee, hip, and trunk angles were measured to evaluate technique. Cyclists showed a more explosive start than speed skaters in the fast-start time trial (cyclists performed first 300 m in 24.70 ± 1.73 s, speed skaters in 26.18 ± 0.79 s). Both trials resulted in reduced MVC (12.0% ± 14.5%), VA (2.4% ± 5.0%), and PT (25.4% ± 15.2%). Blood lactate concentrations after the time trial and the decrease in PT were greater in the fast-start than in the slow-start trial. Speed skaters showed higher trunk angles in the fast-start than in the slow-start trial, while knee angles remained similar. Despite similar instructions, behavioral adaptations in pacing differed between the 2 sports, resulting in equal central and peripheral contributions to muscle fatigue in both sports. This provides evidence for the importance of neurophysiological aspects in the regulation of pacing. It also stresses the notion that optimal pacing needs to be studied sport specifically, and coaches should be aware of this.

  4. The impact of the perception of rhythmic music on oscillatory self-paced movements

    Directory of Open Access Journals (Sweden)

    Mathieu ePeckel

    2014-09-01

    Full Text Available Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20s before a 2s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e. motor/perceptual resonance. In general, our results give support to the notion that rhythmic music is processed in a

  5. TREATMENT PLANNING, PACING, AND COUNTERTRANSFERENCE: PERSPECTIVES ON THE PSYCHOTHERAPY OF EARLY AFFECT-CONFUSION

    Directory of Open Access Journals (Sweden)

    Richard G. Erskine

    2012-12-01

    Full Text Available This article is a rejoinder and elaboration on the article “Early Affect-Confusion: The ‘Borderline’ Between Despair and Rage: Part 1 of a Case Study Trilogy” and addresses the distinction between personality style, pattern, and disorder. It describes the pacing of a time-limited psychotherapy, the use of phenomenological inquiry in resolving transferential enactments, and the psychological function of idealization.

  6. Time course and degree of hyperinflation with metronome-paced tachypnea in COPD patients.

    Science.gov (United States)

    Weigt, S Samuel; Abrazado, Marlon; Kleerup, Eric C; Tashkin, Donald P; Cooper, Christopher B

    2008-10-01

    In COPD patients, tachypnea should increase (dynamic) hyperinflation by shortening expiratory time. We developed a method to evaluate the time course and degree of dynamic hyperinflation during metronome-paced tachypnea. Fourteen patients with stable COPD (FEV(1) 43 +/- 13% predicted) were studied. Inspiratory capacity (IC) was measured breathing through a flow transducer. Subjects paced their respiratory rate (f(R)) at 20/min, 30/min and 40/min for 60-second periods in response to audible tones generated by a computer. IC measurements were obtained at baseline and after 30 and 60 seconds at each f(R). End-tidal carbon dioxide was monitored and f(R) was allowed to return to baseline between periods of tachypnea. Tachypnea produced reductions in IC of 200 +/- 240 ml, 380 +/- 330 ml and 540 +/- 300 ml after 30 seconds at 20/min, 30/min and 40/min, respectively. IC reduction at 60 seconds was similar to 30 seconds for each f(R). In patients with moderate-to-severe COPD, the dynamic hyperinflation induced by metronome-paced tachypnea was shown to occur rapidly and be complete by 30 seconds for a given f(R). Controlled increments in f(R) produced stepwise increases in dynamic hyperinflation. This standardized method could be a useful and easier method of assessing dynamic hyperinflation in COPD patients before and after therapeutic interventions.

  7. Potential Effect of Physical Activity Calorie Equivalent (PACE) Labeling on Adult Fast Food Ordering and Exercise.

    Science.gov (United States)

    Antonelli, Ray; Viera, Anthony J

    2015-01-01

    Numeric calorie content labels show limited efficacy in reducing the number of calories ordered from fast food meals. Physical activity calorie equivalent (PACE) labels are an alternative that may reduce the number of calories ordered in fast food meals while encouraging patrons to exercise. A total of 1000 adults from 47 US states were randomly assigned via internet survey to one of four generic fast food menus: no label, calories only, calories + minutes, or calories + miles necessary to walk to burn off the calories. After completing hypothetical orders participants were asked to rate the likelihood of calorie-only and PACE labels to influence (1) food choice and (2) physical activity. Respondents (n = 823) ordered a median of 1580 calories from the no-label menu, 1200 from the calories-only menu, 1140 from the calories + minutes menu, and 1210 from the calories + miles menu (p = 0.0001). 40% of respondents reported that PACE labels were "very likely" to influence food item choice vs. 28% for calorie-only labels (pcalorie-only labels (pcalories ordered in fast food meals and may have the added benefit of encouraging exercise.

  8. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking

    Science.gov (United States)

    Buhmann, Jeska; Desmet, Frank; Moens, Bart; Van Dyck, Edith; Leman, Marc

    2016-01-01

    The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended) synchronization. But is this velocity effect still present with non-instructed (spontaneous) synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities. PMID:27167064

  9. Theory of the development of alternans in the heart during controlled diastolic interval pacing

    Science.gov (United States)

    Otani, Niels F.

    2017-09-01

    The beat-to-beat alternation in action potential durations (APDs) in the heart, called APD alternans, has been linked to the development of serious cardiac rhythm disorders, including ventricular tachycardia and fibrillation. The length of the period between action potentials, called the diastolic interval (DI), is a key dynamical variable in the standard theory of alternans development. Thus, methods that control the DI may be useful in preventing dangerous cardiac rhythms. In this study, we examine the dynamics of alternans during controlled-DI pacing using a series of single-cell and one-dimensional (1D) fiber models of alternans dynamics. We find that a model that combines a so-called memory model with a calcium cycling model can reasonably explain two key experimental results: the possibility of alternans during constant-DI pacing and the phase lag of APDs behind DIs during sinusoidal-DI pacing. We also find that these results can be replicated by incorporating the memory model into an amplitude equation description of a 1D fiber. The 1D fiber result is potentially concerning because it seems to suggest that constant-DI control of alternans can only be effective over only a limited region in space.

  10. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking.

    Directory of Open Access Journals (Sweden)

    Jeska Buhmann

    Full Text Available The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended synchronization. But is this velocity effect still present with non-instructed (spontaneous synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities.

  11. Self-Paced Prioritized Curriculum Learning With Coverage Penalty in Deep Reinforcement Learning.

    Science.gov (United States)

    Ren, Zhipeng; Dong, Daoyi; Li, Huaxiong; Chen, Chunlin; Zhipeng Ren; Daoyi Dong; Huaxiong Li; Chunlin Chen; Dong, Daoyi; Li, Huaxiong; Chen, Chunlin; Ren, Zhipeng

    2018-06-01

    In this paper, a new training paradigm is proposed for deep reinforcement learning using self-paced prioritized curriculum learning with coverage penalty. The proposed deep curriculum reinforcement learning (DCRL) takes the most advantage of experience replay by adaptively selecting appropriate transitions from replay memory based on the complexity of each transition. The criteria of complexity in DCRL consist of self-paced priority as well as coverage penalty. The self-paced priority reflects the relationship between the temporal-difference error and the difficulty of the current curriculum for sample efficiency. The coverage penalty is taken into account for sample diversity. With comparison to deep Q network (DQN) and prioritized experience replay (PER) methods, the DCRL algorithm is evaluated on Atari 2600 games, and the experimental results show that DCRL outperforms DQN and PER on most of these games. More results further show that the proposed curriculum training paradigm of DCRL is also applicable and effective for other memory-based deep reinforcement learning approaches, such as double DQN and dueling network. All the experimental results demonstrate that DCRL can achieve improved training efficiency and robustness for deep reinforcement learning.

  12. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking.

    Science.gov (United States)

    Buhmann, Jeska; Desmet, Frank; Moens, Bart; Van Dyck, Edith; Leman, Marc

    2016-01-01

    The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended) synchronization. But is this velocity effect still present with non-instructed (spontaneous) synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities.

  13. Prevalence of venous obstruction in permanent endovenous pacing in newborns and infants: follow-up study.

    Science.gov (United States)

    Stojanov, Petar; Vranes, Mile; Velimirovic, Dusan; Zivkovic, Mirjana; Kocica, Mladen J; Davidovic, Lazar; Neskovic, Voislava; Stajevic, Mila

    2005-05-01

    We examined the prevalence of venous obstruction in 12 newborns and infants with permanent endovenous ventricular pacing, clinically, and by ultrasonographic assessment of hemodynamics (spontaneity, phasicity, velocity, and turbulence of flow) and morphologic parameters (compressibility, wall thickness, and thrombus presence). All implantations of single ventricular unipolar endovenous steroid leads, were performed via cephalic vein, and pacemakers were placed in subcutaneous pocket in right prepectoral region. After the vascular surgeon has carefully examined all children for presence of venous collaterals in the chest wall, morphologic and hemodynamic parameters of the subclavian, axillary, and internal jugular veins, were assessed by linear-array color Doppler. Lead capacity (LC) was calculated for each patient. Mean age of patients at implant was 6.2 months (range 1 day-12 months), mean weight 6.5 kg (range 2.25-10 kg), and mean height 60.9 cm (range 48-78 cm). Mean LC was 1.99 (range 1.14-3.07). Total follow-up was 1023 and mean follow-up 85.2 pacing months (range 3-156). No clinical signs of venous obstruction were observed. Mild stenosis (20%) of subclavian vein was found by color Doppler in 2/12 patients. Both had adequate lead diameter for body surface. Permanent endovenous pacing is a feasible procedure, even in children of body weight less than 10 kg, with quite acceptable impact on venous system patency.

  14. First reported experience with intramuscular diaphragm pacing in replacing positive pressure mechanical ventilators in children.

    Science.gov (United States)

    Onders, Raymond P; Ponsky, Todd A; Elmo, MaryJo; Lidsky, Karen; Barksdale, Edward

    2011-01-01

    Diaphragm pacing (DP) has been shown to successfully replace mechanical ventilators for adult tetraplegic patients with chronic respiratory insufficiency. This is the first report of DP in ventilator-dependent children. This was a prospective interventional experience under institutional review board approval. Diaphragm pacing involves outpatient laparoscopic diaphragm motor point mapping to identify the site where stimulation causes maximum diaphragm contraction with implantation of 4 percutaneous intramuscular electrodes. Diaphragm conditioning ensues to wean the child from the ventilator. Six children were successfully implanted ranging from 5 to 17 years old with the smallest 15 kg in weight. Length of time on mechanical ventilation ranged from 11 days to 7.6 years with an average of 3.2 years. In all patients, DP provided tidal volumes above basal needs. Five of the patients underwent a home-based weaning program, whereas one patient who was implanted only 11 days post spinal cord injury never returned to the ventilator with DP use. Another patient was weaned from the ventilator full time but died of complications of his underlying brain stem tumor. The remaining patients weaned from the ventilator for over 14 hours a day and/or are actively conditioning their diaphragms. Diaphragm pacing successfully replaced mechanical ventilators, which improves quality of life. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. A positron emission tomography study of self-paced finger movements at different frequencies

    International Nuclear Information System (INIS)

    Kawashima, R.; Inoue, K.; Sugiura, M.; Okada, K.; Ogawa, A.; Fukuda, H.

    1999-01-01

    Regional cerebral blood flow was measured in six right-handed volunteers using positron emission tomography during tasks involving repetitive self-paced finger tapping at five different frequencies. The contralateral primary sensorimotor cortex, the pre-supplementary motor area and the cingulate motor area showed significant activation during self-paced finger tapping tasks, compared with the resting state. A positive correlation between the regional cerebral blood flow and the movement frequency was found only in the primary sensorimotor cortex. In the pre-supplementary motor area and the cingulate motor area, however, activity increased when the subject employed movement frequencies faster or slower than his own pace. The same tendency was noted with respect to the relative variability of the inter-tapping interval.The results therefore indicate that the activity of the pre-supplementary motor area and the cingulate motor area may well be related to the increased difficulty in motor control rather than to the execution of the movement itself. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. Pacing Profiles in Competitive Track Races: Regulation of Exercise Intensity Is Related to Cognitive Ability.

    Science.gov (United States)

    Van Biesen, Debbie; Hettinga, Florentina J; McCulloch, Katina; Vanlandewijck, Yves

    2016-01-01

    Pacing has been defined as the goal-directed regulation of exercise intensity over an exercise bout, in which athletes need to decide how and when to invest their energy. The purpose of this study was to explore if the regulation of exercise intensity during competitive track races is different between runners with and without intellectual impairment, which is characterized by significant limitations in intellectual functioning (IQ ≤ 75) and adaptive behavioral deficits, diagnosed before the age of 18. The samples included elite runners with intellectual impairment ( N = 36) and a comparison group of world class runners without impairment ( N = 39), of which 47 were 400 m runners (all male) and 28 were 1500 m-runners (15 male and 13 female). Pacing was analyzed by means of 100 m split times (for 400 m races) and 200 m split times (for 1500 m races). Based on the split times, the average velocity was calculated for four segments of the races. Velocity fluctuations were defined as the differences in velocity between consecutive race segments. A mixed model ANOVA revealed significant differences in pacing profiles between runners with and without intellectual impairment ( p competitive races.

  17. Running pace decrease during a marathon is positively related to blood markers of muscle damage.

    Directory of Open Access Journals (Sweden)

    Juan Del Coso

    Full Text Available BACKGROUND: Completing a marathon is one of the most challenging sports activities, yet the source of running fatigue during this event is not completely understood. The aim of this investigation was to determine the cause(s of running fatigue during a marathon in warm weather. METHODOLOGY/PRINCIPAL FINDINGS: We recruited 40 amateur runners (34 men and 6 women for the study. Before the race, body core temperature, body mass, leg muscle power output during a countermovement jump, and blood samples were obtained. During the marathon (27 °C; 27% relative humidity running fatigue was measured as the pace reduction from the first 5-km to the end of the race. Within 3 min after the marathon, the same pre-exercise variables were obtained. RESULTS: Marathoners reduced their running pace from 3.5 ± 0.4 m/s after 5-km to 2.9 ± 0.6 m/s at the end of the race (P 15% pace reduction had elevated post-race myoglobin (1318 ± 1411 v 623 ± 391 µg L(-1; P<0.05, lactate dehydrogenase (687 ± 151 v 583 ± 117 U L(-1; P<0.05, and creatine kinase (564 ± 469 v 363 ± 158 U L(-1; P = 0.07 in comparison with marathoners that preserved their running pace reasonably well throughout the race. However, they did not differ in their body mass change (-3.1 ± 1.0 v -3.0 ± 1.0%; P = 0.60 or post-race body temperature (38.7 ± 0.7 v 38.9 ± 0.9 °C; P = 0.35. CONCLUSIONS/SIGNIFICANCE: Running pace decline during a marathon was positively related with muscle breakdown blood markers. To elucidate if muscle damage during a marathon is related to mechanistic or metabolic factors requires further investigation.

  18. PACE METAR

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — METAR is a routine scheduled observation and is the primary observation code used in the United States to satisfy requirements for reporting surface meteorological...

  19. An appropriate compression pace is important for securing the quality of hands-only CPR--a manikin study.

    Science.gov (United States)

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-09-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-second break between the sets. The percentage of compressions deeper than 5 cm at pace-110-g decreased significantly from 22.1 ± 4.7% in the first set to 16.7 ± 4.4%* in the second set (*p CPR.

  20. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    Science.gov (United States)

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing

    DEFF Research Database (Denmark)

    Riahi, Sam; Nielsen, Jens Cosedis; Hjortshøj, Søren

    2012-01-01

    AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular...... patients (17%) with the leads in a non-apical position, HR 0.67, CI 0.45-1.00, P = 0.05. After adjustments this difference was non-significant. The incidence of HF was not associated with %VP (P = 0.57).CONCLUSION: In patients with SSS, HF was not associated with pacing mode, %VP, or ventricular lead...... localization. This suggests that DDDR pacing is safe in patients with SSS without precipitating HF....

  2. Graphic console for analysis of severe accidents visualization of OEs, NAEs and calculation of the source term for the NPP-LV (CoGrAAS)

    International Nuclear Information System (INIS)

    Sandoval V, S.; Mendoza E, P. R.; Gonzalez C, J. M.; Cecenas F, M.; Tijerina S, F.

    2016-09-01

    In response to the Fukushima Daiichi nuclear power plant accident, the NRC conducted an analysis and issued recommendations to improve the safety of the nuclear reactors. These include strengthening and integrating emergency response capabilities and emphasizing periodic staff training, the performance of simulation exercises. As a tool to observe these recommendations, the Graphic Console was developed for Analysis of Severe Accidents, Visualization of OEs, NAEs and calculation of the source term for nuclear power plant of Laguna Verde (NPP-LV ; CoGrAAS). The CoGrAAS is a computer system that displays in an integrated, graphic and dynamic way the information of a catalog of previously simulated accident scenarios. Has core mimics, vessel, primary containment and safety systems, trend graph of thermodynamic and radiological variables and the emergency procedures (OEs), chronological list of events, windows with detailed information for the dry-well, among others. The use of CoGrAAS allows that staff to understand and become familiar with the thermo-hydraulic progression of actual scenarios that exceed the design basis including those with core damage as severe accidents. The system enables personnel to develop an integral vision of the scenarios during the exercises and drills by observing and analyzing the evolution of the main reactor, core and primary containment variables, the response of emergency systems and the influence of that progression on OEs and the emergency action levels (NAEs). The CoGrAAS allows o observe the radiological variables and obtain the source term, to make the projection of doses, at any time within the scenario evolution. Thus, not only can the phenomenology of severe accidents be analyzed and understood, it is also possible to exercise, verify and evaluate the performance of critical tasks in the application of procedures, guidelines and emergency management plans. (Author)

  3. Alterações clínicas e hematológicas em gatos domésticos naturalmente infectados pelo Vírus da Leucemia Felina (FeLV

    Directory of Open Access Journals (Sweden)

    Nádia Rossi de Almeida

    2016-07-01

    Full Text Available O Vírus da Leucemia Felina (FeLV é um retrovírus imunossupressor e o maior causador de morte dentre as doenças infecciosas felinas. O FeLV induz ao desenvolvimento de distúrbios degenerativos e/ou mieloproliferativos nos animais infectados, que sucumbem à infecções oportunistas devido à imunossupressão. As alterações nos parâmetros hematológicos em gatos FeLV positivos muitas vezes não condizem com o estado clínico do animal, podendo o mesmo ser um portador assintomático apresentando alterações hematológicas, ou sintomático sem alterações nestes parâmetros. O objetivo do presente estudo foi avaliar as alterações nos parâmetros clínicos e hematológicos de gatos domésticos infectados naturalmente pelo FeLV, nas fases sintomáticas e assintomáticas da doença. Desta forma, foram selecionados 40 gatos domiciliados previamente testados como positivos para o FeLV pela técnica de imunofluorescência indireta. O exame físico foi realizado e os animais foram separados em dois grupos: os gatos sintomáticos e os assintomáticos para a infecção. Amostras de sangue para a realização de hemograma foram coletadas de ambos os grupos e o teste estatístico ANOVA foi realizado para a comparação das alterações hematológicas. O exame clínico indicou 37,5% dos gatos como portadores assintomáticos e 62,5% sintomáticos, sendo a perda de peso e alterações de mucosas os achados mais frequentes. O hemograma evidenciou anemia e linfopenia como os parâmetros hematológicos que apresentaram diferenças estatísticas entre os dois grupos estudados, sendo que 56% dos gatos assintomáticos apresentaram anemia. Em face aos resultados encontrados, concluiu-se que gatos FeLV positivos sintomáticos apresentaram alterações hematológicas condizentes com o quadro de imunossupressão clínico.

  4. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    Science.gov (United States)

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential

  5. Towards PACE Atmospheric Correction, Aerosol and Cloud Products: Making Use of Expanded Spectral, Angular and Polarimetric Information.

    Science.gov (United States)

    Remer, L. A.; Boss, E.; Ahmad, Z.; Cairns, B.; Chowdhary, J.; Coddington, O.; Davis, A. B.; Dierssen, H. M.; Diner, D. J.; Franz, B. A.; Frouin, R.; Gao, B. C.; Garay, M. J.; Heidinger, A.; Ibrahim, A.; Kalashnikova, O. V.; Knobelspiesse, K. D.; Levy, R. C.; Omar, A. H.; Meyer, K.; Platnick, S. E.; Seidel, F. C.; van Diedenhoven, B.; Werdell, J.; Xu, F.; Zhai, P.; Zhang, Z.

    2017-12-01

    NASA's Science Team for the Plankton, Aerosol, Clouds, ocean Ecosystem (PACE) mission is concluding three years of study exploring the science potential of expanded spectral, angular and polarization capability for space-based retrievals of water leaving radiance, aerosols and clouds. The work anticipates future development of retrievals to be applied to the PACE Ocean Color Instrument (OCI) and/or possibly a PACE Multi-Angle Polarimeter (MAP). In this presentation we will report on the Science Team's accomplishments associated with the atmosphere (significant efforts are also directed by the ST towards the ocean). Included in the presentation will be sensitivity studies that explore new OCI capabilities for aerosol and cloud layer height, aerosol absorption characterization, cloud property retrievals, and how we intend to move from heritage atmospheric correction algorithms to make use of and adjust to OCI's hyperspectral and UV wavelengths. We will then address how capabilities will improve with the PACE MAP, how these capabilities from both OCI and MAP correspond to specific societal benefits from the PACE mission, and what is still needed to close the gaps in our understanding before the PACE mission can realize its full potential.

  6. Pacing and decision making in sport and exercise: the roles of perception and action in the regulation of exercise intensity.

    Science.gov (United States)

    Smits, Benjamin L M; Pepping, Gert-Jan; Hettinga, Florentina J

    2014-06-01

    In pursuit of optimal performance, athletes and physical exercisers alike have to make decisions about how and when to invest their energy. The process of pacing has been associated with the goal-directed regulation of exercise intensity across an exercise bout. The current review explores divergent views on understanding underlying mechanisms of decision making in pacing. Current pacing literature provides a wide range of aspects that might be involved in the determination of an athlete's pacing strategy, but lacks in explaining how perception and action are coupled in establishing behaviour. In contrast, decision-making literature rooted in the understanding that perception and action are coupled provides refreshing perspectives on explaining the mechanisms that underlie natural interactive behaviour. Contrary to the assumption of behaviour that is managed by a higher-order governor that passively constructs internal representations of the world, an ecological approach is considered. According to this approach, knowledge is rooted in the direct experience of meaningful environmental objects and events in individual environmental processes. To assist a neuropsychological explanation of decision making in exercise regulation, the relevance of the affordance competition hypothesis is explored. By considering pacing as a behavioural expression of continuous decision making, new insights on underlying mechanisms in pacing and optimal performance can be developed.

  7. Prognostic value of atrial pacing and thallium-201 scintigraphy in patients with stable chest pain

    International Nuclear Information System (INIS)

    Stratmann, H.G.; Mark, A.L.; Walter, K.E.; Williams, G.A.

    1989-01-01

    The value of atrial pacing and thallium-201 scintigraphy for assessing risk of subsequent cardiac events was examined in 210 patients with stable chest pain. Follow-up information was complete in 195 patients (mean age 61 years). Over an average follow-up of 19 months, cardiac events occurred in 38 patients--unstable angina in 20, nonfatal acute myocardial infarction in 6 and death from cardiac causes in 12. A history of previous myocardial infarction, diabetes mellitus, systemic hypertension or peripheral vascular disease at the time of pacing was not associated with an increased frequency of subsequent cardiac events. Six of 38 patients with later cardiac events had a history of congestive heart failure, compared with 8 of 157 without cardiac events (p less than 0.05). Neither pacing-induced angina, ST depression, nor the presence of a fixed perfusion defect was significantly more frequent in patients with cardiac events as a whole compared with patients without such events. Reversible defects and abnormal scans (reversible or fixed defects) were present, respectively, in 19 and 31 of 38 patients with cardiac events, compared with 42 and 79 patients, respectively, of the 157 patients without cardiac events (both p less than 0.01). In patients who developed unstable angina, a reversible defect was seen in 13 and an abnormal scan in 16 (both p less than 0.01 compared with patients without cardiac events). In 12 patients who died from a primary cardiac event, fixed defects were present in 8 and an abnormal scan in 11 (p less than 0.05 and p less than 0.01, respectively, compared with patients without cardiac events)

  8. Indicators of a poor outcome after temporary pacing in patients with complete atrioventricular block

    International Nuclear Information System (INIS)

    Kazmi, U.; Hyder, S.N.; Sheikh, A.M.

    2013-01-01

    Background: Temporary pace maker (tpm) implantation is an emergency procedure, performed in symptomatic patients with AV block We report our experience of temporary pacing at a tertiary care center. It is the first study of its type from a local center. Objectives: To study the clinical course of patients after tpm implantation and to determine indicators of a poor outcome after tpm implantation. Methods: This was descriptive retrospective study. Data of all tpm procedures performed at Children Hospital from 2006 to 2012 was retrieved. We excluded patients with surgically placed tpm leads. All patients receiving transvenous tpm were included in our study. Results: Total of 12 patients received tpm, 8 were male (66.6%) and 4 were female (33.3%). Median age was 6 years ( range 1.4 -13 year ). Mean weight was 30kg, (range 8.7 - 50kg). All of them presented with complete heart block.One patient each had post diphtheria cardiomyopathy, unknown poisoning. The rest had congenital heart block. The mean period between tpm to ppm implantation was 5 days, (range 1 - 30 days). One patient spontaneously reverted to sinus rhythm(8.3%), 6 had ppm implantation (58.3%), 5 patients expired (33.3%). A low Ejection Fraction was found to be associated with a poor outcome (p<0.01). Variables that were associated with a poor outcome(mortality), were SOB (p<0.015), weak pulses (p<0.015), and hepatomegaly (p<0.01). Conclusion: Low Ejection Fraction and Heart failure is associated with a poor outcome and increased mortality in patients with complete AV block. We suggest that pacing should be considered in patients earlier, before they develop signs or symptoms of cardiac dysfunction. (author)

  9. Effect of steroid eluting versus conventional electrodes on propafenone induced rise in chronic ventricular pacing threshold.

    Science.gov (United States)

    Cornacchia, D; Fabbri, M; Maresta, A; Nigro, P; Sorrentino, F; Puglisi, A; Ricci, R; Peraldo, C; Fazzari, M; Pistis, G

    1993-12-01

    The aim of this study was to evaluate chronic ventricular pacing threshold increase after oral propafenone therapy. Eighty-three patients affected by advanced atrioventricular block and sick sinus syndrome were studied at least 3 months after pacemaker implantation, before and after oral propafenone therapy (450-900 mg/day based on body weight). The patients were subdivided into three groups according to the type of unipolar electrode that was implanted: group I (41 patients) Medtronic CapSure 4003, group II (30 patients) Medtronic Target Tip 4011, and group III (12 patients) Osypka Vy screw-in lead. In all cases a Medtronic unipolar pacemaker was implanted: 30 Minix, 23 Activitrax, 14 Elite, 12 Legend, and 4 Pasys. Propafenone blood level was measured in 75 patients 3-5 hours after propafenone administration. The pacing autothreshold was measured at 0.8 V, 1.6 V, and 2.5 V by reducing pulse width. At the three different outputs before and after propafenone, threshold increments were significantly lower in group I in comparison with group II and group III (propafenone ranging from < 0.001 to < 0.05). No significant difference was found in pacing impedance or in propafenone plasma concentration in the three groups. Strength-duration curves were drawn for each group at baseline and after propafenone administration. Before propafenone, in group I, the knee was markedly shifted to the left and downward as compared to the classic curve, so that the steep part was predominant; in group II and group III this shift was progressively less evident.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Work Rate during Self-paced Exercise is not Mediated by the Rate of Heat Storage.

    Science.gov (United States)

    Friesen, Brian J; Périard, Julien D; Poirier, Martin P; Lauzon, Martin; Blondin, Denis P; Haman, Francois; Kenny, Glen P

    2018-01-01

    To date, there have been mixed findings on whether greater anticipatory reductions in self-paced exercise intensity in the heat are mediated by early differences in rate of body heat storage. The disparity may be due to an inability to accurately measure minute-to-minute changes in whole-body heat loss. Thus, we evaluated whether early differences in rate of heat storage can mediate exercise intensity during self-paced cycling at a fixed rate of perceived exertion (RPE of 16; hard-to-very-hard work effort) in COOL (15°C), NORMAL (25°C), and HOT (35°C) ambient conditions. On separate days, nine endurance-trained cyclists exercised in COOL, NORMAL, and HOT conditions at a fixed RPE until work rate (measured after first 5 min of exercise) decreased to 70% of starting values. Whole-body heat loss and metabolic heat production were measured by direct and indirect calorimetry, respectively. Total exercise time was shorter in HOT (57 ± 20 min) relative to both NORMAL (72 ± 23 min, P = 0.004) and COOL (70 ± 26 min, P = 0.045). Starting work rate was lower in HOT (153 ± 31 W) compared with NORMAL (166 ± 27 W, P = 0.024) and COOL (170 ± 33 W, P = 0.037). Rate of heat storage was similar between conditions during the first 4 min of exercise (all P > 0.05). Thereafter, rate of heat storage was lower in HOT relative to NORMAL and COOL until 30 min of exercise (last common time-point between conditions; all P exercise. No differences were measured at end exercise. We show that rate of heat storage does not mediate exercise intensity during self-paced exercise at a fixed RPE in cool to hot ambient conditions.

  11. Ensemble of Neural Network Conditional Random Fields for Self-Paced Brain Computer Interfaces

    Directory of Open Access Journals (Sweden)

    Hossein Bashashati

    2017-07-01

    Full Text Available Classification of EEG signals in self-paced Brain Computer Interfaces (BCI is an extremely challenging task. The main difficulty stems from the fact that start time of a control task is not defined. Therefore it is imperative to exploit the characteristics of the EEG data to the extent possible. In sensory motor self-paced BCIs, while performing the mental task, the user’s brain goes through several well-defined internal state changes. Applying appropriate classifiers that can capture these state changes and exploit the temporal correlation in EEG data can enhance the performance of the BCI. In this paper, we propose an ensemble learning approach for self-paced BCIs. We use Bayesian optimization to train several different classifiers on different parts of the BCI hyper- parameter space. We call each of these classifiers Neural Network Conditional Random Field (NNCRF. NNCRF is a combination of a neural network and conditional random field (CRF. As in the standard CRF, NNCRF is able to model the correlation between adjacent EEG samples. However, NNCRF can also model the nonlinear dependencies between the input and the output, which makes it more powerful than the standard CRF. We compare the performance of our algorithm to those of three popular sequence labeling algorithms (Hidden Markov Models, Hidden Markov Support Vector Machines and CRF, and to two classical classifiers (Logistic Regression and Support Vector Machines. The classifiers are compared for the two cases: when the ensemble learning approach is not used and when it is. The data used in our studies are those from the BCI competition IV and the SM2 dataset. We show that our algorithm is considerably superior to the other approaches in terms of the Area Under the Curve (AUC of the BCI system.

  12. Issues of work intensity, pace, and sustainability in relation to work context and nutritional status.

    Science.gov (United States)

    Panter-Brick, Catherine

    2003-01-01

    This article raises issues about work intensity, pace, and sustainability during physical activity, focusing attention on the nature of work in labor-intensive societies, the management of exertion in habitual tasks, and the health and broad socioeconomic correlates of alternative ways to regulate work patterns. At the heart of this review are concerns to document human adaptability (in terms of the physical and behavioral management of heavy work) and to renew debate regarding the conceptualization and measurement of work intensity (variously evaluated in absolute or relative terms, as indexed by oxygen consumption, energy expenditure, percentage maximal work capacity, heart rate elevation, time and motion indicators, or physiological cost). Three questions are examined: Is heavy work primarily a matter of time or energy intensity? How is heavy work habitually sustained? What is the bigger picture relating work performance to work context and to nutritional or health status? It is argued that many arduous activities, such as carrying loads, demand endurance over time rather than intensive effort per unit time, and that work pace management lies in regulating both the rate of work and the time in rest during physical activity. Furthermore, strategies that maximize long-term endurance (adopted by "tortoises") and those that maximize short-term productivity (adopted by "hares") are appropriate to different work contexts (e.g., a subsistence or wage-labor economy) and suit individuals with different health status and ability. Thus, work intensity is an important aspect of the links between physical activity, health, productivity, and society, as noted in literature reviewing objectives for sustainable development and public health messages for disease risk management. These areas of scholarship are underresearched, partly because consensus has been slow in agreeing on which are the best measures of work pace and work intensity for use in field situations, and which

  13. Bike and run pacing on downhill segments predict Ironman triathlon relative success.

    Science.gov (United States)

    Johnson, Evan C; Pryor, J Luke; Casa, Douglas J; Belval, Luke N; Vance, James S; DeMartini, Julie K; Maresh, Carl M; Armstrong, Lawrence E

    2015-01-01

    Determine if performance and physiological based pacing characteristics over the varied terrain of a triathlon predicted relative bike, run, and/or overall success. Poor self-regulation of intensity during long distance (Full Iron) triathlon can manifest in adverse discontinuities in performance. Observational study of a random sample of Ironman World Championship athletes. High performing and low performing groups were established upon race completion. Participants wore global positioning system and heart rate enabled watches during the race. Percentage difference from pre-race disclosed goal pace (%off) and mean HR were calculated for nine segments of the bike and 11 segments of the run. Normalized graded running pace (accounting for changes in elevation) was computed via analysis software. Step-wise regression analyses identified segments predictive of relative success and HP and LP were compared at these segments to confirm importance. %Off of goal velocity during two downhill segments of the bike (HP: -6.8±3.2%, -14.2±2.6% versus LP: -1.2±4.2%, -5.1±11.5%; p<0.020) and %off from NGP during one downhill segment of the run (HP: 4.8±5.2% versus LP: 33.3±38.7%; p=0.033) significantly predicted relative performance. Also, HP displayed more consistency in mean HR (141±12 to 138±11 bpm) compared to LP (139±17 to 131±16 bpm; p=0.019) over the climb and descent from the turn-around point during the bike component. Athletes who maintained faster relative speeds on downhill segments, and who had smaller changes in HR between consecutive up and downhill segments were more successful relative to their goal times. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Effects of self-paced interval and continuous training on health markers in women.

    Science.gov (United States)

    Connolly, Luke J; Bailey, Stephen J; Krustrup, Peter; Fulford, Jonathan; Smietanka, Chris; Jones, Andrew M

    2017-11-01

    To compare the effects of self-paced high-intensity interval and continuous cycle training on health markers in premenopausal women. Forty-five inactive females were randomised to a high-intensity interval training (HIIT; n = 15), continuous training (CT; n = 15) or an inactive control (CON; n = 15) group. HIIT performed 5 × 5 min sets comprising repetitions of 30-s low-, 20-s moderate- and 10-s high-intensity cycling with 2 min rest between sets. CT completed 50 min of continuous cycling. Training was completed self-paced, 3 times weekly for 12 weeks. Peak oxygen uptake (16 ± 8 and 21 ± 12%), resting heart rate (HR) (-5 ± 9 and -4 ± 7 bpm) and visual and verbal learning improved following HIIT and CT compared to CON (P HIIT (P HIIT and CT, and there were no changes in fasting serum lipids, fasting blood [glucose] or [glucose] during an oral glucose tolerance test following either HIIT or CT (P > 0.05). No outcome variable changed in the CON group (P > 0.05). Twelve weeks of self-paced HIIT and CT were similarly effective at improving cardiorespiratory fitness, resting HR and cognitive function in inactive premenopausal women, whereas blood pressure, submaximal HR, well-being and body mass adaptations were training-type-specific. Both training methods improved established health markers, but the adaptations to HIIT were evoked for a lower time commitment.

  15. Oxford and Cambridge Boat Race: Performance, Pacing and Tactics Between 1890 and 2014.

    Science.gov (United States)

    Edwards, Andrew M; Guy, Joshua H; Hettinga, Florentina J

    2016-10-01

    Currently no studies have examined the historical performances of Oxford and Cambridge Boat Race crews in the context of performance, pacing and tactics which is surprising as the event has routinely taken place annually for over 150 years on the same course. The purpose of this study was twofold, to firstly examine the historical development of performances and physical characteristics of crews over 124 years of the Oxford and Cambridge Boat Race between 1890 and 2014 and secondly to investigate the pacing and tactics employed by crews over that period. Linear regression modelling was applied to investigate the development of performance and body size for crews of eight male individuals over time from Boat Race archive data. Performance change over time was further assessed in 10-year clusters while four intra-race checkpoints were used to examine pacing and tactics. Significant correlations were observed between performance and time (1890-2014) for both Oxford (r = -0.67; p tactical advantage from commencing on either the Surrey or Middlesex station beyond chance alone; however, all crews (n = 228) adopted a fast-start strategy, with 81 % of victories achieved by the crew leading the race at the first intra-race checkpoint (24 % of total distance). Crews leading the race at the final checkpoint (83 % of total distance; 1143 m) achieved victory on 94 % of occasions. Performances and physical characteristics of the crews have changed markedly since 1890, with faster heavier crews now common. Tactically, gaining the early lead position with a fast-start strategy seems particularly meaningful to success in the Boat Race throughout the years, and has been of greater importance to race outcome than factors such as the starting station.

  16. Ice slurry ingestion does not enhance self-paced intermittent exercise in the heat.

    Science.gov (United States)

    Gerrett, N; Jackson, S; Yates, J; Thomas, G

    2017-11-01

    This study aimed to determine if ice slurry ingestion improved self-paced intermittent exercise in the heat. After a familiarisation session, 12 moderately trained males (30.4 ± 3.4 year, 1.8 ± 0.1 cm, 73.5 ± 14.3 kg, V˙O 2max 58.5 ± 8.1 mL/kg/min) completed two separate 31 min self-paced intermittent protocols on a non-motorised treadmill in 30.9 ± 0.9 °C, 41.1 ± 4.0% RH. Thirty minutes prior to exercise, participants consumed either 7.5 g/kg ice slurry (0.1 ± 0.1 °C) (ICE) or 7.5 g/kg water (23.4 ± 0.9 °C) (CONTROL). Despite reductions in T c (ΔT c : -0.51 ± 0.3 °C, P exercise, ICE did not enhance self-paced intermittent exercise compared to CONTROL. The average speed during the walk (CONTROL: 5.90 ± 1.0 km, ICE: 5.90 ± 1.0 km), jog (CONTROL: 8.89 ± 1.7 km, ICE: 9.11 ± 1.5 km), run (CONTROL: 12.15 ± 1.7 km, ICE: 12.54 ± 1.5 km) and sprint (CONTROL: 17.32 ± 1.3 km, ICE: 17.18 ± 1.4 km) was similar between conditions (P > 0.05). Mean T sk , T b , blood lactate, heart rate and RPE were similar between conditions (P > 0.05). The findings suggest that lowering T c prior to self-paced intermittent exercise does not translate into an improved performance. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Basal metabolism in tropical birds: latitude, altitude, and the ‘pace of life’

    OpenAIRE

    Londoño, Gustavo Adolfo

    2015-01-01

    Life history varies across latitudes, with the ‘pace of life’ being ‘slower’ in tropical regions. Because life history is coupled to energy metabolism via allocation tradeoffs and links between performance capacity and energy use, low metabolic intensity is expected in tropical animals. Low metabolism has been reported for lowland tropical birds, but it is unclear if this is due to ‘slow’ life history or to a warm, stable environment. We measured basal metabolic rates (BMR) of 253 bird spe...

  18. Effects of self-paced interval and continuous training on health markers in women

    OpenAIRE

    Connolly, Luke J; Bailey, Stephen J; Krustrup, Peter; Fulford, Jonathan; Smietanka, Chris; Jones, Andrew M

    2017-01-01

    PURPOSE: To compare the effects of self-paced high-intensity interval and continuous cycle training on health markers in premenopausal women.METHODS: Forty-five inactive females were randomised to a high-intensity interval training (HIIT; n = 15), continuous training (CT; n = 15) or an inactive control (CON; n = 15) group. HIIT performed 5 × 5 min sets comprising repetitions of 30-s low-, 20-s moderate- and 10-s high-intensity cycling with 2 min rest between sets. CT completed 50 min of conti...

  19. Similarities and Differences in Pacing Patterns in a 161-km and 101-km Ultra-Distance Road Race.

    Science.gov (United States)

    Tan, Philip L S; Tan, Frankie H Y; Bosch, Andrew N

    2016-08-01

    Tan, PLS, Tan, FHY, and Bosch, AN. Similarities and differences in pacing patterns in a 161-km and 101-km ultra-distance road race. J Strength Cond Res 30(8): 2145-2155, 2016-The purpose of this study was to establish and compare the pacing patterns of fast and slow finishers in a tropical ultra-marathon. Data were collected from the Craze Ultra-marathon held on the 22nd and 21st of September in 2012 and 2013, respectively. Finishers of the 161-km (N = 47) and 101-km (N = 120) categories of the race were divided into thirds (groups A-C) by merit of finishing time. Altogether, 17 and 11 split times were recorded for the 161-km and 101-km finishers, respectively, and used to calculate the mean running speed for each distance segment. Running speed for the first segment was normalized to 100, with all subsequent splits adjusted accordingly. Running speed during the last 5 km was calculated against the mean race pace to establish the existence of an end spurt. A reverse J-shaped pacing profile was demonstrated in all groups for both distance categories and only 38% of the finishers executed an end spurt. In the 101-km category, in comparison with groups B and C, group A maintained a significantly more even pace (p = 0.013 and 0.001, respectively) and completed the race at a significantly higher percent of initial starting speed (p = 0.001 and 0.001, respectively). Descriptive data also revealed that the top 5 finishers displayed a "herd-behavior" by staying close to the lead runner in the initial portion of the race. These findings demonstrate that to achieve a more even pace, recreational ultra-runners should adopt a patient sustainable starting speed, with less competitive runners setting realistic performance goals whereas competitive runners with a specific time goal to consider running in packs of similar pace.

  20. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  1. The effect of aging on pacing strategies of cross-country skiers and the role of performance level.

    Science.gov (United States)

    Nikolaidis, Pantelis Theodoros; Villiger, Elias; Rosemann, Thomas; Knechtle, Beat

    2018-01-01

    The participation of master cross-country (XC) skiers in training and competition has increased during the last decades; however, little is known yet about whether these athletes differ from their younger counterparts in aspects of performance such as pacing. Therefore, the aim of the present study was to examine the combined effect of age and performance (race time) on pacing in cross-country (XC) skiing. We analyzed all finishers ( n  = 79,722) in 'Vasaloppet' from 2012 to 2017, the largest cross-country skiing race in the world, classified according to their race time into 10 groups: 3-4 h, 4-5 h, ..., 12-13 h. A trivial main effect of sex on total pace range was observed ( p  < 0.001, η 2  = 0.002), where women (44.1 ± 10.2%) had larger total pace range than men (40.9 ± 11.8%). A large main effect of performance group on total pace range was shown ( p  < 0.001, η 2  = 0.160), where the smallest total pace range was 21.8 ± 1.9% (3-4 h group) and the largest 50.1 ± 9.9% (10-11 h group). A trivial sex×performance group interaction on total pace range was found ( p  < 0.001, η 2  = 0.001) with the largest sex difference in pacing shown in 9-10 h group. A trivial and small main effect of age was found in women ( p  < 0.001, η 2  = 0.005) and men ( p  < 0.001, η 2  = 0.011), respectively, where the masters had smaller total pace range than their younger counterparts. A trivial age group×performance group interaction on total pace range was observed in both women ( p  < 0.001, η 2  = 0.008) and men ( p  < 0.001, η 2  = 0.006) with smaller differences among age groups in the faster performance groups. In summary, master XC skiers adopted a relatively even pacing independently from their race time and the differences in pacing from the younger XC skiers were more pronounced in the slower masters. These findings suggest that exercise attenuates the decline of performance in

  2. Cardiac pacing systems and implantable cardiac defibrillators (ICDs): a radiological perspective of equipment, anatomy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K. E-mail: apqz59@dsl.pipex.comk1511@hotmail.com; Burchard, F.; Papouchado, M.; Wilde, P

    2004-08-01

    Cardiac pacing is a proven and effective treatment in the management of many cardiac arrhythmias. Implantable cardiac defibrillators (ICDs) are beneficial for certain patient groups with a history of serious, recurrent ventricular dysrhythmias, with a high risk of sudden cardiac death. Pacemaker devices take many forms and are highly visible on the chest radiograph. The radiographic appearances of ICDs and pacemakers can be similar and are subject to similar complications. The anatomical approach to the implantation, the type of device used and anatomical variations will all affect the appearance of these devices on the chest film. Pacemaker complications identified radiographically include pneumothorax, lead malpositioning, lead displacement or fracture, fracture of outer conductor coil, loose connection between the lead and pacemaker connector block, lack of redundant loops in paediatric patients and excessive manipulation of the device by the patient (Twiddler's syndrome). This pictorial review highlights the role of chest radiography in the diagnosis of post-cardiac pacing and ICD insertion complications, as well as demonstrating the normal appearances of the most frequently implanted devices.

  3. Structured Approach vs. Self-Paced Modular Approach in Teaching Trigonometry

    Directory of Open Access Journals (Sweden)

    Rodin M. Paspasan

    2015-12-01

    Full Text Available The study aimed to determine which approach in the teaching of Mathematics allowed students to achieve a higher mathematical performance and to establish the learning styles of the students to showed greater confidence on a written posttest - the self-paced modular approach or the structured lecture demonstration based approach. The instruments used in the study are Trigonometry Achievement Test (PTAT designed by the researcher and the Grasha - Reichmann Student Learning Style Survey. Hence. the result shows on the test of significant difference on the respondents learning styles and level of performance established independent learning conditions and demonstrate remarkably higher mathematical performance, respectively. In the light of the statistical analysis and the findings of the study, it could be generalized that SPMA made the students learning styles more independent because they prefer to work at their own pace. Hence, SPMA help them also improve their level of performance in relation to plane trigonometry regardless of their mathematical abilities compared to structured approach. Along these lines, the subsequent recommendations are presented for consideration: The teachers should use collective learning style inventories so that students remain interested throughout their mathematics course. And should use SPMA in teaching trigonometry and other disciplines in the field of mathematics.

  4. Effect of Music Tempo on Attentional Focus and Perceived Exertion during Self-selected Paced Walking

    Science.gov (United States)

    SILVA, ALDO COELHO; DOS SANTOS FERREIRA, SANDRO; ALVES, RAGAMI CHAVES; FOLLADOR, LUCIO; DA SILVA, SERGIO GREGORIO

    2016-01-01

    This study investigated the influence of music on the rating of perceived exertion (RPE) and attentional focus during walking at a self-selected pace. Fifteen overweight and obese women volunteered to participate in the study. They underwent four sessions: the first for incremental maximal test and anthropometric measurement followed by three experimental sessions. After the first session, they were exposed to three 30-minute walking sessions at a self-selected pace in a counterbalanced order: fast-tempo music (FT), medium-tempo music (MT) and no-music control (NM). Borg’s RPE Scale and an Attentional Focus Questionnaire were used to measure the perceptual response and attentional focus, respectively. Results showed that the RPE was higher in the no-music control than in the medium-tempo music (12.05 ± 0.6 vs. 10.5 ± 0.5). Furthermore, dissociative attentional focus was greater for both conditions with music in comparison with the no-music control (NM= 39.0 ± 4.1; MT= 48.4 ± 4.1 and FT= 47.9 ± 4.5). The results indicated that the use of music during walking can modulate attentional focus, increasing dissociative thought, and medium-tempo music can reduce the RPE. PMID:27990220

  5. The behavior of an opponent alters pacing decisions in 4-km cycling time trials.

    Science.gov (United States)

    Konings, Marco J; Schoenmakers, Patrick P J M; Walker, Andrew J; Hettinga, Florentina J

    2016-05-01

    The present study aimed to explore how athletes respond to different behaviors of their opponents. Twelve moderately to highly physically active participants with at least two years of cycling experience completed four 4-km time trials on a Velotron cycle ergometer. After a familiarization time trial (FAM), participants performed three experimental time trials in randomized order with no opponent (NO), a virtual opponent who started slower and finished faster compared to FAM (OP-SLOWFAST), or a virtual opponent who started faster and finished slower compared to FAM (OP-FASTSLOW). Repeated-measures ANOVAs (Ppower output, velocity and RPE. OP-SLOWFAST and OP-FASTSLOW were completed faster compared to NO (385.5±27.5, 385.0±28.6, and 390.6±29.3s, respectively). An interaction effect for condition×distance (F=3.944, Ppower outputs by the participants in the initial 750m compared to a slower starting opponent. The present study is the first to show that the behavior of an opponent affects pacing-related decisions in laboratory-controlled conditions. Our findings support the recently proposed interdependence of perception and action, and emphasize the interaction with the environment as an important determinant for an athlete's pacing decisions, especially during the initial stages of a race. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Novel Insights into Structure-Activity Relationships of N-Terminally Modified PACE4 Inhibitors.

    Science.gov (United States)

    Kwiatkowska, Anna; Couture, Frédéric; Levesque, Christine; Ly, Kévin; Beauchemin, Sophie; Desjardins, Roxane; Neugebauer, Witold; Dory, Yves L; Day, Robert

    2016-02-04

    PACE4 plays important roles in prostate cancer cell proliferation. The inhibition of this enzyme has been shown to slow prostate cancer progression and is emerging as a promising therapeutic strategy. In previous work, we developed a highly potent and selective PACE4 inhibitor, the multi-Leu (ML) peptide, an octapeptide with the sequence Ac-LLLLRVKR-NH2 . Here, with the objective of developing a useful compound for in vivo administration, we investigate the effect of N-terminal modifications. The inhibitory activity, toxicity, stability, and cell penetration properties of the resulting analogues were studied and compared to the unmodified inhibitor. Our results show that the incorporation of a polyethylene glycol (PEG) moiety leads to a loss of antiproliferative activity, whereas the attachment of a lipid chain preserves or improves it. However, the lipidated peptides are significantly more toxic when compared with their unmodified counterparts. Therefore, the best results were achieved not by the N-terminal extension but by the protection of both ends with the d-Leu residue and 4-amidinobenzylamide, which yielded the most stable inhibitor, with an excellent activity and toxicity profile. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Technical summary of the Performance Assessment Calculational Exercises for 1990 (PACE-90)

    International Nuclear Information System (INIS)

    Barnard, R.W.; Dockery, H.A.

    1991-06-01

    A Performance Assessment Calculational Exercise for 1990 (PACE-90) was coordinated by the Yucca Mountain Site Characterization Project Office for a total-system performance-assessment problem. The primary objectives of the exercise were to develop performance-assessment computational capabilities of the Yucca Mountain Project participates and to aid in identifying critical elements and processes associated with the calculation. The problem defined for PACE-90 was simulation of a ''nominal case'' groundwater flow and transport of a selected group of radionuclides through a portion of Yucca Mountain. Both 1-D and 2-D calculations were run for a modeling period of 100,000 years. The nuclides used, 99 Tc, 135 Cs, 129 I, and 237 Np, were representative of ''classes'' of long-lived nuclides expected to be present in the waste inventory. Movement of the radionuclides was simulated through a detailed hydrostratigraphy developed from Yucca Mountain data specifically for this exercise. The results showed that, for the specified conditions with the conceptual models used in the problem, no radioactive contamination reached the water table, 230 m below the repository. However, due to the unavailability of sufficient site-specific data, the results of this exercise cannot be considered a comprehensive total-system- performance assessment of the Yucca Mountain site as a high-level- waste repository. 46 refs., 94 figs., 19 tabs

  8. Effect of Music Tempo on Attentional Focus and Perceived Exertion during Self-selected Paced Walking.

    Science.gov (United States)

    Silva, Aldo Coelho; Dos Santos Ferreira, Sandro; Alves, Ragami Chaves; Follador, Lucio; DA Silva, Sergio Gregorio

    2016-01-01

    This study investigated the influence of music on the rating of perceived exertion (RPE) and attentional focus during walking at a self-selected pace. Fifteen overweight and obese women volunteered to participate in the study. They underwent four sessions: the first for incremental maximal test and anthropometric measurement followed by three experimental sessions. After the first session, they were exposed to three 30-minute walking sessions at a self-selected pace in a counterbalanced order: fast-tempo music (FT), medium-tempo music (MT) and no-music control (NM). Borg's RPE Scale and an Attentional Focus Questionnaire were used to measure the perceptual response and attentional focus, respectively. Results showed that the RPE was higher in the no-music control than in the medium-tempo music (12.05 ± 0.6 vs. 10.5 ± 0.5). Furthermore, dissociative attentional focus was greater for both conditions with music in comparison with the no-music control (NM= 39.0 ± 4.1; MT= 48.4 ± 4.1 and FT= 47.9 ± 4.5). The results indicated that the use of music during walking can modulate attentional focus, increasing dissociative thought, and medium-tempo music can reduce the RPE.

  9. Partnerships for Active Children in Elementary Schools (PACES): First year process evaluation.

    Science.gov (United States)

    Egan, Cate A; Webster, Collin; Weaver, R Glenn; Brian, Ali; Stodden, David; Russ, Laura; Nesbitt, Danielle; Vazou, Spyridoula

    2018-04-01

    Movement integration (MI) is a strategy within comprehensive school physical activity programs (CSPAP). School-university partnerships are recommended to leverage teachers' capacity to use MI. A mixed method process evaluation was conducted of the first year of implementing Partnerships for Active Children in Elementary Schools (PACES). Classroom teachers (N=12) from four schools participated. Data were collected in Fall 2014 (baseline) and Spring 2015 (∼ four months of intervention) using the System for Observing Student Movement in Academic Routines and Transitions and semi-structured interviews. There were no significant differences between intervention classrooms and control classrooms MI promotion. Differences approaching significance (U=5, p=0.04, d=1.2) were observed when comparing classrooms that received two (community of practice, community-based participatory research) or three components (two components plus service learning) of the intervention and classrooms that received one (community of practice) or no components. Qualitative findings revealed that teachers in classrooms that were more successful responded more favorably to the intervention components than teachers in classrooms that were less successful. Quantitative and qualitative results supported the effectiveness of community-based participatory research as a component of PACES. This study provides information about MI process variables in the context of a CSPAP intervention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Efficiency of timing delays and electrode positions in optimization of biventricular pacing: a simulation study.

    Science.gov (United States)

    Miri, Raz; Graf, Iulia M; Dössel, Olaf

    2009-11-01

    Electrode positions and timing delays influence the efficacy of biventricular pacing (BVP). Accordingly, this study focuses on BVP optimization, using a detailed 3-D electrophysiological model of the human heart, which is adapted to patient-specific anatomy and pathophysiology. The research is effectuated on ten heart models with left bundle branch block and myocardial infarction derived from magnetic resonance and computed tomography data. Cardiac electrical activity is simulated with the ten Tusscher cell model and adaptive cellular automaton at physiological and pathological conduction levels. The optimization methods are based on a comparison between the electrical response of the healthy and diseased heart models, measured in terms of root mean square error (E(RMS)) of the excitation front and the QRS duration error (E(QRS)). Intra- and intermethod associations of the pacing electrodes and timing delays variables were analyzed with statistical methods, i.e., t -test for dependent data, one-way analysis of variance for electrode pairs, and Pearson model for equivalent parameters from the two optimization methods. The results indicate that lateral the left ventricle and the upper or middle septal area are frequently (60% of cases) the optimal positions of the left and right electrodes, respectively. Statistical analysis proves that the two optimization methods are in good agreement. In conclusion, a noninvasive preoperative BVP optimization strategy based on computer simulations can be used to identify the most beneficial patient-specific electrode configuration and timing delays.

  11. The Self-Paced Graz Brain-Computer Interface: Methods and Applications

    Directory of Open Access Journals (Sweden)

    Reinhold Scherer

    2007-01-01

    Full Text Available We present the self-paced 3-class Graz brain-computer interface (BCI which is based on the detection of sensorimotor electroencephalogram (EEG rhythms induced by motor imagery. Self-paced operation means that the BCI is able to determine whether the ongoing brain activity is intended as control signal (intentional control or not (non-control state. The presented system is able to automatically reduce electrooculogram (EOG artifacts, to detect electromyographic (EMG activity, and uses only three bipolar EEG channels. Two applications are presented: the freeSpace virtual environment (VE and the Brainloop interface. The freeSpace is a computer-game-like application where subjects have to navigate through the environment and collect coins by autonomously selecting navigation commands. Three subjects participated in these feedback experiments and each learned to navigate through the VE and collect coins. Two out of the three succeeded in collecting all three coins. The Brainloop interface provides an interface between the Graz-BCI and Google Earth.

  12. Pacing profiles and pack running at the IAAF World Half Marathon Championships.

    Science.gov (United States)

    Hanley, Brian

    2015-01-01

    The aim of this study was to describe the pacing profiles and packing behaviour of athletes competing in the IAAF World Half Marathon Championships. Finishing and split times were collated for 491 men and 347 women across six championships. The mean speeds for each intermediate 5 km and end 1.1 km segments were calculated, and athletes grouped according to finishing time. The best men and women largely maintained their split speeds between 5 km and 15 km, whereas slower athletes had decreased speeds from 5 km onwards. Athletes were also classified by the type of packing behaviour in which they engaged. Those who ran in packs throughout the race had smaller decreases in pace than those who did not, or who managed to do so only to 5 km. While some athletes' reduced speeds from 15 to 20 km might have been caused by fatigue, it was also possibly a tactic to aid a fast finish that was particularly beneficial to medallists. Those athletes who ran with the same competitors throughout sped up most during the finish. Athletes are advised to identify rivals likely to have similar abilities and ambitions and run with them as part of their pre-race strategy.

  13. A 'slow pace of life' in Australian old-endemic passerine birds is not accompanied by low basal metabolic rates.

    Science.gov (United States)

    Bech, Claus; Chappell, Mark A; Astheimer, Lee B; Londoño, Gustavo A; Buttemer, William A

    2016-05-01

    Life history theory suggests that species experiencing high extrinsic mortality rates allocate more resources toward reproduction relative to self-maintenance and reach maturity earlier ('fast pace of life') than those having greater life expectancy and reproducing at a lower rate ('slow pace of life'). Among birds, many studies have shown that tropical species have a slower pace of life than temperate-breeding species. The pace of life has been hypothesized to affect metabolism and, as predicted, tropical birds have lower basal metabolic rates (BMR) than temperate-breeding birds. However, many temperate-breeding Australian passerines belong to lineages that evolved in Australia and share 'slow' life-history traits that are typical of tropical birds. We obtained BMR from 30 of these 'old-endemics' and ten sympatric species of more recently arrived passerine lineages (derived from Afro-Asian origins or introduced by Europeans) with 'faster' life histories. The BMR of 'slow' temperate-breeding old-endemics was indistinguishable from that of new-arrivals and was not lower than the BMR of 'fast' temperate-breeding non-Australian passerines. Old-endemics had substantially smaller clutches and longer maximal life spans in the wild than new arrivals, but neither clutch size nor maximum life span was correlated with BMR. Our results suggest that low BMR in tropical birds is not functionally linked to their 'slow pace of life' and instead may be a consequence of differences in annual thermal conditions experienced by tropical versus temperate species.

  14. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  15. Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Casavant, David; Betzold, Robert; Sheldon, Todd; Tang, Feng; Mueller, Megan; Lingle, John

    2005-08-01

    Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.

  16. Increased heart rate caused by atrial pacing with the closed-loop stimulation function prevented micturition syncope

    Directory of Open Access Journals (Sweden)

    Tatsuo Haraki, MD,PhD

    2013-10-01

    Full Text Available A 70-year-old man had been experiencing syncope several times a year. We implanted a DDD pacemaker with closed-loop stimulation (CLS function. When he urinated early in the morning, his increased atrial pacing rates elevated his heart rate (HR during and after micturition. After implantation of the DDD-CLS mode, he did not experience symptoms. In contrast, in the DDD-R mode, his intrinsic HR changed to atrial pacing after micturition but decreased to the basal rate within 2 min, and he experienced a sense of cold perspiration and presyncope. Increased HRs caused by atrial pacing with the CLS function were useful in the prevention of micturition syncope.

  17. Application of radionuclide ventriculography phase analysis in patients with atrial or ventricular pacing for detecting ventricular abnormal excitation

    International Nuclear Information System (INIS)

    Shi Rongfang; Wang Zhonggan; Li Shengting

    1996-01-01

    The aim of the study was to increase the accuracy of detecting ventricular abnormal excitation. During atrial or ventricular pacing, radionuclide ventriculography phase analysis (RNV-PA) was performed in 17 patients with Wolff-Parkinson-White (W-P-W) syndrome and paroxysmal supra ventricular tachycardia (PSVT) and ventricular tachycardia (PVT). During pacing, detection rate of abnormal excitation by RNV-PA was 95.5%, compared with 68.2% during basic conduction. Atrial or ventricular pacing can significantly increase the detection rate of abnormal excitation by RNV-PA in patients with W-P-W syndrome. It may be a valuable method for identifying the abnormal excitation and estimating the therapeutic effect of ablation

  18. Human radiation studies: Remembering the early years. Oral history of physiologist Nello Pace, Ph.D., August 16, 1994

    International Nuclear Information System (INIS)

    1995-06-01

    Dr. Nello Pace was interviewed by representatives of the US DOE Office of Human Radiation Experiments (OHRE). Dr. Pace was selected fro the interview because of the positions he held with the US Navy, at the University of California, Berkeley, and as Director of the White Mountain Research Station near Bishop, California. Following a brief biographical sketch, Dr. Pace related his remembrances concerning tritium injections experiments in animals and humans during World War II, the development of Medical Physics Degree Programs at UC Berkeley, conducting the first radiation survey at Nagasaki after the bomb, and the establishment of a research laboratory at White Mountain. He also offers reflections on Shields Warren and comments on the public's attitudes towards radiation both then and now

  19. Environmental proxies of antigen exposure explain variation in immune investment better than indices of pace of life.

    Science.gov (United States)

    Horrocks, Nicholas P C; Hegemann, Arne; Ostrowski, Stéphane; Ndithia, Henry; Shobrak, Mohammed; Williams, Joseph B; Matson, Kevin D; Tieleman, B I

    2015-01-01

    Investment in immune defences is predicted to covary with a variety of ecologically and evolutionarily relevant axes, with pace of life and environmental antigen exposure being two examples. These axes may themselves covary directly or inversely, and such relationships can lead to conflicting predictions regarding immune investment. If pace of life shapes immune investment then, following life history theory, slow-living, arid zone and tropical species should invest more in immunity than fast-living temperate species. Alternatively, if antigen exposure drives immune investment, then species in antigen-rich tropical and temperate environments are predicted to exhibit higher immune indices than species from antigen-poor arid locations. To test these contrasting predictions we investigated how variation in pace of life and antigen exposure influence immune investment in related lark species (Alaudidae) with differing life histories and predicted risks of exposure to environmental microbes and parasites. We used clutch size and total number of eggs laid per year as indicators of pace of life, and aridity, and the climatic variables that influence aridity, as correlates of antigen abundance. We quantified immune investment by measuring four indices of innate immunity. Pace of life explained little of the variation in immune investment, and only one immune measure correlated significantly with pace of life, but not in the predicted direction. Conversely, aridity, our proxy for environmental antigen exposure, was predictive of immune investment, and larks in more mesic environments had higher immune indices than those living in arid, low-risk locations. Our study suggests that abiotic environmental variables with strong ties to environmental antigen exposure can be important correlates of immunological variation.

  20. Could persistency of current of injury forecast successful active-fixation pacing lead implantation?

    Science.gov (United States)

    Shali, Shalaimaiti; Su, Yangang; Qin, Shengmei; Ge, Junbo

    2018-05-01

    Presence of adequate current of injury (COI) was recognized as a sign of favorable pacemaker lead outcome. Little is known regarding the value of its dynamic behavior. We sought to test whether persistency of COI could predict active-fixation pacing lead performance. COI was monitored up to 10min after right ventricular (RV) pacing electrode fixation. COI persistency was defined as the percentage of COI magnitude relative to its initial measurement. An unacceptable pacing threshold (≥1.0V in acute evaluation or ≥2.0V over 2-year follow-up) with or without lead dislodgement was considered as lead failure. Lead implantation was attempted for 217 times in 174 patients (age 66.3±7.8years, 78 female). Acute lead failures occurred 43 times. Independent predictors of acute lead failure were RV enlargement (odds ratio [OR] 1.23, 95% confidential interval [CI] 1.11-2.04, P=0.033), absence of COI (OR 3.13, 95%CI 2.08-9.09, P=0.027), and COI persistency at 5min (OR 0.32, 95%CI 0.20-0.69, P=0.001) and 10min (OR 0.41, 95%CI 0.13-0.77, P=0.001). The optimal cutoffs were COI 5min persistency ≥50% (sensitivity 81.4%; specificity 81.9%) and COI 10min persistency ≥20% (sensitivity 86%; specificity 88.6%). There were 12 lead failures during 24.0±6.4months of follow-up. Patients with COI 5min persistency ≥50% had higher event-free survival compared to those with COI 5min persistency <50% (hazard ratio 3.54, 95% CI 1.04-12.06, P=0.043). COI persistency appears to be a valuable indicator for both acute and long-term outcome of active-fixation pacemaker leads. A precipitous decline in COI may require more attention to make sure of the lead performance. Copyright © 2018 Elsevier Ireland Ltd. All rights reserved.

  1. Antifibrillatory effects of renal denervation on ventricular fibrillation in a canine model of pacing-induced heart failure.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Huang, Shangwei; Han, Yanxin; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2018-01-01

    What is the central question of this study? In the present study, we investigated the effects of renal denervation on the vulnerability to ventricular fibrillation and the ventricular electrical properties in a rapid pacing-induced heart failure canine model. What is the main finding and its importance? Renal denervation significantly attenuated the process of heart failure and improved left ventricular systolic dysfunction, stabilized ventricular electrophysiological properties and decreased the vulnerability of the heart to ventricular fibrillation during heart failure. Thus, renal denervation can attenuate ventricular electrical remodelling and exert a potential antifibrillatory action in a pacing-induced heart failure canine model. In this study, we investigated the effects of renal denervation (RDN) on the vulnerability to ventricular fibrillation (VF) and the ventricular electrical properties in a canine model of pacing-induced heart failure (HF). Eighteen beagles were divided into the following three groups: control (n = 6), HF (n = 6) and HF+RDN (n = 6). Heart failure was induced by rapid right ventricular pacing. Renal denervation was performed simultaneously with the pacemaker implantation in the HF+RDN group. A 64-unipolar basket catheter was used to perform global endocardial mapping of the left ventricle. The restitution properties and dispersion of refractoriness were estimated from the activation recovery intervals (ARIs) by a pacing protocol. The VF threshold (VFT) was defined as the maximal pacing cycle length required to induce VF using a specific pacing protocol. The defibrillation threshold (DFT) was measured by an up-down algorithm. Renal denervation partly restored left ventricular systolic function and attenuated the process of HF. Compared with the control group, the VFT in the HF group was decreased by 27% (106 ± 8.0 versus 135 ± 10 ms, P Renal denervation significantly flattened the ventricular ARI restitution curve by 15% (1

  2. Challenge of Helping Introductory Physics Students Transfer Their Learning by Engaging with a Self-Paced Learning Tutorial

    Directory of Open Access Journals (Sweden)

    Emily Megan Marshman

    2018-03-01

    Full Text Available With advances in digital technology, research-validated self-paced learning tools can play an increasingly important role in helping students with diverse backgrounds become good problem solvers and independent learners. Thus, it is important to ensure that all students engage with self-paced learning tools effectively in order to learn the content deeply, develop good problem-solving skills, and transfer their learning from one context to another. Here, we first provide an overview of a holistic framework for engaging students with self-paced learning tools so that they can transfer their learning to solve novel problems. The framework not only takes into account the features of the self-paced learning tools but also how those tools are implemented, the extent to which the tools take into account student characteristics, and whether factors related to students’ social environments are accounted for appropriately in the implementation of those tools. We then describe an investigation in which we interpret the findings using the framework. In this study, a research-validated self-paced physics tutorial was implemented in both controlled one-on-one interviews and in large enrollment, introductory calculus-based physics courses as a self-paced learning tool. We find that students who used the tutorial in a controlled one-on-one interview situation performed significantly better on transfer problems than those who used it as a self-paced learning tool in the large-scale implementation. The findings suggest that critically examining and taking into account how the self-paced tools are implemented and incentivized, student characteristics including their self-regulation and time-management skills, and social and environmental factors can greatly impact the extent and manner in which students engage with these learning tools. Getting buy in from students about the value of these tools and providing appropriate support while implementing them is

  3. Influence of flood risk management measures on socio-economic and ecological vulnerabilities in a large water system - A case study of Lake Vänern and the Göta älv River, Sweden

    Science.gov (United States)

    Nyberg, L.; Blumenthal, B.; Johansson, M.

    2009-04-01

    An important feature of flood risk management is to integrate ecological, economical and social aspects on prevention and mitigation measures. Protective measures could potentially be in conflict with sound functions of ecosystems or cause conflicts in upstream/downstream relations. A case study of a large water system in south-western Sweden - Lake Vänern and the Göta älv River - was used to analyse the relation between socio-economic and ecological vulnerabilities and to identify opposing interests regarding water level fluctuations and high-water-level situations in the lake. Lake Vänern with its area of 5,500 km2 is the largest lake in Sweden and within the European Union. The Göta älv River runs from the lake outlet 90 km down to the sea at Gothenburg. The total catchment area upstream of the river mouth is 51,000 km2. Vänern and Göta älv are used for hydropower production, shipping, tourism, fishing, drinking water supply, as waste water recipient, etc. The risk system is complex with flood risks in the lake and in Gothenburg which are connected to landslide risks and industrial risks in the river valley, and where the drinking water supply for 700,000 persons in the Gothenburg region is at stake. Because of the landslide risks along the downstream river, the water discharge from Lake Vänern is limited. During periods of high inflow to the lake, situations of high water-levels last at least for six months. Substantial increases in precipitation during the 21st century, according to IPCC, will give a corresponding increase in flood risks.

  4. X-ray crystal structure of the N-terminal region of Moloney murine leukemia virus integrase and its implications for viral DNA recognition: N-Terminal Region of M-MuLV Integrase

    Energy Technology Data Exchange (ETDEWEB)

    Guan, Rongjin [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Aiyer, Sriram [Department of Pharmacology, Robert Wood Johnson Medical School, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Cote, Marie L. [Department of Biochemistry, Robert Wood Johnson Medical School, UMDNJ, Piscataway New Jersey 08854; Xiao, Rong [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Jiang, Mei [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Acton, Thomas B. [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Roth, Monica J. [Department of Pharmacology, Robert Wood Johnson Medical School, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Montelione, Gaetano T. [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Biochemistry, Robert Wood Johnson Medical School, UMDNJ, Piscataway New Jersey 08854

    2017-02-03

    The retroviral integrase (IN) carries out the integration of a dsDNA copy of the viral genome into the host DNA, an essential step for viral replication. All IN proteins have three general domains, the N-terminal domain (NTD), the catalytic core domain, and the C-terminal domain. The NTD includes an HHCC zinc finger-like motif, which is conserved in all retroviral IN proteins. Two crystal structures of Moloney murine leukemia virus (M-MuLV) IN N-terminal region (NTR) constructs that both include an N-terminal extension domain (NED, residues 1–44) and an HHCC zinc-finger NTD (residues 45–105), in two crystal forms are reported. The structures of IN NTR constructs encoding residues 1–105 (NTR1–105) and 8–105 (NTR8–105) were determined at 2.7 and 2.15 Å resolution, respectively and belong to different space groups. While both crystal forms have similar protomer structures, NTR1–105 packs as a dimer and NTR8–105 packs as a tetramer in the asymmetric unit. The structure of the NED consists of three anti-parallel β-strands and an α-helix, similar to the NED of prototype foamy virus (PFV) IN. These three β-strands form an extended β-sheet with another β-strand in the HHCC Zn2+ binding domain, which is a unique structural feature for the M-MuLV IN. The HHCC Zn2+ binding domain structure is similar to that in HIV and PFV INs, with variations within the loop regions. Differences between the PFV and MLV IN NEDs localize at regions identified to interact with the PFV LTR and are compared with established biochemical and virological data for M-MuLV. Proteins 2017; 85:647–656.

  5. Prolonged self-paced exercise in the heat - environmental factors affecting performance

    DEFF Research Database (Denmark)

    Junge, Nicklas; Jørgensen, Rasmus; Flouris, Andreas D

    2016-01-01

    ) was on average reduced by 15% in the 14 studies that fulfilled the inclusion criteria. Ambient temperature per se was a poor predictor of the integrated environmental heat stress and 2 of the prevailing heat stress indices (WBGT and UTCI) failed to predict the environmental influence on performance. The weighing......In this review we examine how self-paced performance is affected by environmental heat stress factors during cycling time trial performance as well as considering the effects of exercise mode and heat acclimatization. Mean power output during prolonged cycling time trials in the heat (≥30°C...... of wind speed appears to be too low for predicting the effect for cycling in trained acclimatized subjects, where performance may be maintained in outdoor time trials at ambient temperatures as high as 36°C (36°C UTCI; 28°C WBGT). Power output during indoor trials may also be maintained with temperatures...

  6. A Multi-Usable Cloud Service Platform: A Case Study on Improved Development Pace and Efficiency

    Directory of Open Access Journals (Sweden)

    John Lindström

    2018-02-01

    Full Text Available The case study, spanning three contexts, concerns a multi-usable cloud service platform for big data collection and analytics and how the development pace and efficiency of it has been improved by 50–75% by using the Arrowhead framework and changing development processes/practices. Furthermore, additional results captured during the case study are related to technology, competencies and skills, organization, management, infrastructure, and service and support. A conclusion is that when offering a complex offer such as an Industrial Product-Service System, comprising sensors, hardware, communications, software, cloud service platform, etc., it is necessary that the technology, business model, business setup, and organization all go hand in hand during the development and later operation, as all ‘components’ are required for a successful result.

  7. Large-Scale Ocean Circulation-Cloud Interactions Reduce the Pace of Transient Climate Change

    Science.gov (United States)

    Trossman, D. S.; Palter, J. B.; Merlis, T. M.; Huang, Y.; Xia, Y.

    2016-01-01

    Changes to the large scale oceanic circulation are thought to slow the pace of transient climate change due, in part, to their influence on radiative feedbacks. Here we evaluate the interactions between CO2-forced perturbations to the large-scale ocean circulation and the radiative cloud feedback in a climate model. Both the change of the ocean circulation and the radiative cloud feedback strongly influence the magnitude and spatial pattern of surface and ocean warming. Changes in the ocean circulation reduce the amount of transient global warming caused by the radiative cloud feedback by helping to maintain low cloud coverage in the face of global warming. The radiative cloud feedback is key in affecting atmospheric meridional heat transport changes and is the dominant radiative feedback mechanism that responds to ocean circulation change. Uncertainty in the simulated ocean circulation changes due to CO2 forcing may contribute a large share of the spread in the radiative cloud feedback among climate models.

  8. Do changes in the pace of events affect one-off judgments of duration?

    Science.gov (United States)

    Darlow, Hannah M; Dylman, Alexandra S; Gheorghiu, Ana I; Matthews, William J

    2013-01-01

    Five experiments examined whether changes in the pace of external events influence people's judgments of duration. In Experiments 1a-1c, participants heard pieces of music whose tempo accelerated, decelerated, or remained constant. In Experiment 2, participants completed a visuo-motor task in which the rate of stimulus presentation accelerated, decelerated, or remained constant. In Experiment 3, participants completed a reading task in which facts appeared on-screen at accelerating, decelerating, or constant rates. In all experiments, the physical duration of the to-be-judged interval was the same across conditions. We found no significant effects of temporal structure on duration judgments in any of the experiments, either when participants knew that a time estimate would be required (prospective judgments) or when they did not (retrospective judgments). These results provide a starting point for the investigation of how temporal structure affects one-off judgments of duration like those typically made in natural settings.

  9. Do changes in the pace of events affect one-off judgments of duration?

    Directory of Open Access Journals (Sweden)

    Hannah M Darlow

    Full Text Available Five experiments examined whether changes in the pace of external events influence people's judgments of duration. In Experiments 1a-1c, participants heard pieces of music whose tempo accelerated, decelerated, or remained constant. In Experiment 2, participants completed a visuo-motor task in which the rate of stimulus presentation accelerated, decelerated, or remained constant. In Experiment 3, participants completed a reading task in which facts appeared on-screen at accelerating, decelerating, or constant rates. In all experiments, the physical duration of the to-be-judged interval was the same across conditions. We found no significant effects of temporal structure on duration judgments in any of the experiments, either when participants knew that a time estimate would be required (prospective judgments or when they did not (retrospective judgments. These results provide a starting point for the investigation of how temporal structure affects one-off judgments of duration like those typically made in natural settings.

  10. Entrepreneurial Call for Strategic Agility in Fast-Paced Business Environment

    Directory of Open Access Journals (Sweden)

    Arslan Ayub

    2014-06-01

    Full Text Available The 21st century came with blending of threats and opportunities of deep-rooted obstructions of fast-paced business environment. Research on strategic management has consequently increased and grabbed the attention of both academicians and strategic policy makers. The current study is therefore directed to analyze the multifaceted influence of entrepreneurial orientation on strategic agility and organizational performance. The study uses exploratory approach; primary data is collected from 323 professional working in private sectors in twin cities of Islamabad and Rawalpindi, Pakistan. The study found significantly positive relationship between entrepreneurial orientation and strategic agility, entrepreneurial orientation and organizational performance, and strategic agility and organizational performance. The study discusses important implications regarding entrepreneurs‘ deployment of entrepreneurial orientation and strategic agility for enhancing organizational performance.

  11. Social Class, Gender and the Pace of Academic Life: What Kind of Solution is Slow?

    Directory of Open Access Journals (Sweden)

    Heather Mendick

    2014-09-01

    Full Text Available My starting point for this article is the increasing pace of academic life. As the other articles in this special section evidence, the Slow movement, which seeks to challenge our contemporary obsession with speed, is being taken up by many in order to intervene into "fast academia". However, in this article, I suggest we should pause and question what kind of a solution this offers to the current crisis of speed. Working auto/biographically and using examples drawn from popular culture, I argue that Slow is both classed and gendered, re/producing wider patterns of inclusion and exclusion. Specifically, I suggest that Slow naturalises a particular relationship to self which requires not just stability of employment but an individualist way of being, constituting selves that calculate and invest in them-selves for the future. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs140374

  12. Division of labour between Myc and G1 cyclins in cell cycle commitment and pace control.

    Science.gov (United States)

    Dong, Peng; Maddali, Manoj V; Srimani, Jaydeep K; Thélot, François; Nevins, Joseph R; Mathey-Prevot, Bernard; You, Lingchong

    2014-09-01

    A body of evidence has shown that the control of E2F transcription factor activity is critical for determining cell cycle entry and cell proliferation. However, an understanding of the precise determinants of this control, including the role of other cell-cycle regulatory activities, has not been clearly defined. Here, recognizing that the contributions of individual regulatory components could be masked by heterogeneity in populations of cells, we model the potential roles of individual components together with the use of an integrated system to follow E2F dynamics at the single-cell level and in real time. These analyses reveal that crossing a threshold amplitude of E2F accumulation determines cell cycle commitment. Importantly, we find that Myc is critical in modulating the amplitude, whereas cyclin D/E activities have little effect on amplitude but do contribute to the modulation of duration of E2F activation, thereby affecting the pace of cell cycle progression.

  13. Increases in myocardial workload induced by rapid atrial pacing trigger alterations in global metabolism.

    Directory of Open Access Journals (Sweden)

    Aslan T Turer

    Full Text Available To determine whether increases in cardiac work lead to alterations in the plasma metabolome and whether such changes arise from the heart or peripheral organs.There is growing evidence that the heart influences systemic metabolism through endocrine effects and affecting pathways involved in energy homeostasis.Nineteen patients referred for cardiac catheterization were enrolled. Peripheral and selective coronary sinus (CS blood sampling was performed at serial timepoints following the initiation of pacing, and metabolite profiling was performed by liquid chromatography-mass spectrometry (LC-MS.Pacing-stress resulted in a 225% increase in the median rate·pressure product from baseline. Increased myocardial work induced significant changes in the peripheral concentration of 43 of 125 metabolites assayed, including large changes in purine [adenosine (+99%, p = 0.006, ADP (+42%, p = 0.01, AMP (+79%, p = 0.004, GDP (+69%, p = 0.003, GMP (+58%, p = 0.01, IMP (+50%, p = 0.03, xanthine (+61%, p = 0.0006], and several bile acid metabolites. The CS changes in metabolites qualitatively mirrored those in the peripheral blood in both timing and magnitude, suggesting the heart was not the major source of the metabolite release.Isolated increases in myocardial work can induce changes in the plasma metabolome, but these changes do not appear to be directly cardiac in origin. A number of these dynamic metabolites have known signaling functions. Our study provides additional evidence to a growing body of literature on metabolic 'cross-talk' between the heart and other organs.

  14. Influence of prior knowledge of exercise duration on pacing strategies during game-based activities.

    Science.gov (United States)

    Gabbett, Tim J; Walker, Ben; Walker, Shane

    2015-04-01

    To investigate the influence of prior knowledge of exercise duration on the pacing strategies employed during game-based activities. Twelve semiprofessional team-sport athletes (mean ± SD age 22.8 ± 2.1 y) participated in this study. Players performed 3 small-sided games in random order. In one condition (Control), players were informed that they would play the small-sided game for 12 min and then completed the 12-min game. In a 2nd condition (Deception), players were told that they would play the small-sided game for 6 minutes, but after completing the 6-min game, they were asked to complete another 6 min. In a 3rd condition (Unknown), players were not told how long they would be required to play the small-sided game, but the activity was terminated after 12 min. Movement was recorded using a GPS unit sampling at 10 Hz. Post hoc inspection of video footage was undertaken to count the number of possessions and the number and quality of disposals. Higher initial intensities were observed in the Deception (130.6 ± 3.3 m/min) and Unknown (129.3 ± 2.4 m/min) conditions than the Control condition (123.3 ± 3.4 m/min). Greater amounts of high-speed running occurred during the initial phases of the Deception condition, and more low-speed activity occurred during the Unknown condition. A moderately greater number of total skill involvements occurred in the Unknown condition than the Control condition. These findings suggest that during game-based activities, players alter their pacing strategy based on the anticipated endpoint of the exercise bout.

  15. Faster self-paced rate of drinking for alcohol mixed with energy drinks versus alcohol alone.

    Science.gov (United States)

    Marczinski, Cecile A; Fillmore, Mark T; Maloney, Sarah F; Stamates, Amy L

    2017-03-01

    The consumption of alcohol mixed with energy drinks (AmED) has been associated with higher rates of binge drinking and impaired driving when compared with alcohol alone. However, it remains unclear why the risks of use of AmED are heightened compared with alcohol alone even when the doses of alcohol consumed are similar. Therefore, the purpose of this laboratory study was to investigate if the rate of self-paced beverage consumption was faster for a dose of AmED versus alcohol alone using a double-blind, within-subjects, placebo-controlled study design. Participants (n = 16) of equal gender who were social drinkers attended 4 separate test sessions that involved consumption of alcohol (1.97 ml/kg vodka) and energy drinks, alone and in combination. On each test day, the dose assigned was divided into 10 cups. Participants were informed that they would have a 2-h period to consume the 10 drinks. After the self-paced drinking period, participants completed a cued go/no-go reaction time (RT) task and subjective ratings of stimulation and sedation. The results indicated that participants consumed the AmED dose significantly faster (by ∼16 min) than the alcohol dose. For the performance task, participants' mean RTs were slower in the alcohol conditions and faster in the energy-drink conditions. In conclusion, alcohol consumers should be made aware that rapid drinking might occur for AmED beverages, thus heightening alcohol-related safety risks. The fast rate of drinking may be related to the generalized speeding of responses after energy-drink consumption. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Active Self-Paced Learning for Cost-Effective and Progressive Face Identification.

    Science.gov (United States)

    Lin, Liang; Wang, Keze; Meng, Deyu; Zuo, Wangmeng; Zhang, Lei

    2018-01-01

    This paper aims to develop a novel cost-effective framework for face identification, which progressively maintains a batch of classifiers with the increasing face images of different individuals. By naturally combining two recently rising techniques: active learning (AL) and self-paced learning (SPL), our framework is capable of automatically annotating new instances and incorporating them into training under weak expert recertification. We first initialize the classifier using a few annotated samples for each individual, and extract image features using the convolutional neural nets. Then, a number of candidates are selected from the unannotated samples for classifier updating, in which we apply the current classifiers ranking the samples by the prediction confidence. In particular, our approach utilizes the high-confidence and low-confidence samples in the self-paced and the active user-query way, respectively. The neural nets are later fine-tuned based on the updated classifiers. Such heuristic implementation is formulated as solving a concise active SPL optimization problem, which also advances the SPL development by supplementing a rational dynamic curriculum constraint. The new model finely accords with the "instructor-student-collaborative" learning mode in human education. The advantages of this proposed framework are two-folds: i) The required number of annotated samples is significantly decreased while the comparable performance is guaranteed. A dramatic reduction of user effort is also achieved over other state-of-the-art active learning techniques. ii) The mixture of SPL and AL effectively improves not only the classifier accuracy compared to existing AL/SPL methods but also the robustness against noisy data. We evaluate our framework on two challenging datasets, which include hundreds of persons under diverse conditions, and demonstrate very promising results. Please find the code of this project at: http://hcp.sysu.edu.cn/projects/aspl/.

  17. Integrating mobile technology with routine dietetic practice: the case of myPace for weight management.

    Science.gov (United States)

    Harricharan, Michelle; Gemen, Raymond; Celemín, Laura Fernández; Fletcher, David; de Looy, Anne E; Wills, Josephine; Barnett, Julie

    2015-05-01

    The field of Mobile health (mHealth), which includes mobile phone applications (apps), is growing rapidly and has the potential to transform healthcare by increasing its quality and efficiency. The present paper focuses particularly on mobile technology for body weight management, including mobile phone apps for weight loss and the available evidence on their effectiveness. Translation of behaviour change theory into weight management strategies, including integration in mobile technology is also discussed. Moreover, the paper presents and discusses the myPace platform as a case in point. There is little clinical evidence on the effectiveness of currently available mobile phone apps in enabling behaviour change and improving health-related outcomes, including sustained body weight loss. Moreover, it is unclear to what extent these apps have been developed in collaboration with health professionals, such as dietitians, and the extent to which apps draw on and operationalise behaviour change techniques has not been explored. Furthermore, presently weight management apps are not built for use as part of dietetic practice, or indeed healthcare more widely, where face-to-face engagement is fundamental for instituting the building blocks for sustained lifestyle change. myPace is an innovative mobile technology for weight management meant to be embedded into and to enhance dietetic practice. Developed out of systematic, iterative stages of engagement with dietitians and consumers, it is uniquely designed to complement and support the trusted health practitioner-patient relationship. Future mHealth technology would benefit if engagement with health professionals and/or targeted patient groups, and behaviour change theory stood as the basis for technology development. Particularly, integrating technology into routine health care practice, rather than replacing one with the other, could be the way forward.

  18. Automatic user customization for improving the performance of a self-paced brain interface system.

    Science.gov (United States)

    Fatourechi, Mehrdad; Bashashati, Ali; Birch, Gary E; Ward, Rabab K

    2006-12-01

    Customizing the parameter values of brain interface (BI) systems by a human expert has the advantage of being fast and computationally efficient. However, as the number of users and EEG channels grows, this process becomes increasingly time consuming and exhausting. Manual customization also introduces inaccuracies in the estimation of the parameter values. In this paper, the performance of a self-paced BI system whose design parameter values were automatically user customized using a genetic algorithm (GA) is studied. The GA automatically estimates the shapes of movement-related potentials (MRPs), whose features are then extracted to drive the BI. Offline analysis of the data of eight subjects revealed that automatic user customization improved the true positive (TP) rate of the system by an average of 6.68% over that whose customization was carried out by a human expert, i.e., by visually inspecting the MRP templates. On average, the best improvement in the TP rate (an average of 9.82%) was achieved for four individuals with spinal cord injury. In this case, the visual estimation of the parameter values of the MRP templates was very difficult because of the highly noisy nature of the EEG signals. For four able-bodied subjects, for which the MRP templates were less noisy, the automatic user customization led to an average improvement of 3.58% in the TP rate. The results also show that the inter-subject variability of the TP rate is also reduced compared to the case when user customization is carried out by a human expert. These findings provide some primary evidence that automatic user customization leads to beneficial results in the design of a self-paced BI for individuals with spinal cord injury.

  19. Consumer responses to the Wisconsin Partnership Program for Elderly Persons: a variation on the PACE Model.

    Science.gov (United States)

    Kane, Robert L; Homyak, Patricia; Bershadsky, Boris; Lum, Yat-Sang

    2002-04-01

    The Wisconsin Partnership Program (WPP) is a variation on the Program for All-inclusive Care of the Elderly (PACE) model that is designed to be more flexible by allowing frail elderly dual-eligible (for both Medicare and Medicaid) clients to use their regular primary care physicians instead of relying on the physician hired by PACE. Case management is provided by a team of nurse, social worker, and nurse practitioner. The latter is charged with communicating with the client's primary physician. We compared the functional status and satisfaction of WPP elderly enrollees with those of two sets of dually eligible controls drawn from the Medicaid waiver rosters. One set of controls came from persons in the same county who opted not to enroll in WPP. The second came from matched counties that did not have access to the WPP. Enrollees were interviewed in person. Family members were interviewed by telephone. The prevalence of activities of daily living (ADLs) and instrumental activities of daily living (IADLs) dependency was lower for the WPP sample than that for the controls. The pattern of unmet needs was generally comparable. About half of each sample had a written advance directive. Overall, there were few areas of significant difference in beneficiaries' satisfaction. The WPP families were more satisfied than either control group that services were provided when needed and were better coordinated. There were no significant differences in the prevalence of any aspect of care burden. The impact of WPP seems limited. There is some evidence that families perceive better coordinated care. A more complete evaluation will await the analysis of the differences in utilization patterns between WPP and the controls.

  20. Pacing Behavior and Tactical Positioning in 1500-m Short-Track Speed Skating.

    Science.gov (United States)

    Konings, Marco J; Noorbergen, Olaf S; Parry, David; Hettinga, Florentina J

    2016-01-01

    To gain more insight in pacing behavior and tactical positioning in 1500-m short-track speed skating, a sport in which several athletes directly compete in the same race. Lap times and intermediate rankings of elite 1500-m short-track- skating competitors were collected over the season 2012-13 (N = 510, 85 races). Two statistical approaches were used to assess pacing behavior and tactical positioning. First, lap times were analyzed using a MANOVA, and for each lap differences between sex, race type, final rankings, and stage of competition were determined. Second, Kendall tau b correlations were used to assess relationships between intermediate and final rankings. In addition, intermediate rankings of the winner of each race were examined. In 1500 m (13.5 laps of 111.12 m), correlations between intermediate and final ranking gradually increased throughout the race (eg, lap 1, r = .05; lap 7, r = .26; lap 13, r = .85). Moreover, the percentage of race winners skating in the leading position was over 50% during the last 3 laps. Top finishers were faster than bottom-place finishers only during the last 5 laps, with on average 0.1- to 1.5-s faster lap times of the race winners compared with the others during the last 5 laps. Although a fast start led to faster finishing times, top finishers were faster than bottom-placed finishers only during the last 5 laps. Moreover, tactical positioning at 1 of the foremost positions during the latter phase of the race appeared to be a strong determinant of finishing position.