WorldWideScience

Sample records for drain current model

  1. An analytical drain current model for symmetric double-gate MOSFETs

    Science.gov (United States)

    Yu, Fei; Huang, Gongyi; Lin, Wei; Xu, Chuanzhong

    2018-04-01

    An analytical surface-potential-based drain current model of symmetric double-gate (sDG) MOSFETs is described as a SPICE compatible model in this paper. The continuous surface and central potentials from the accumulation to the strong inversion regions are solved from the 1-D Poisson's equation in sDG MOSFETs. Furthermore, the drain current is derived from the charge sheet model as a function of the surface potential. Over a wide range of terminal voltages, doping concentrations, and device geometries, the surface potential calculation scheme and drain current model are verified by solving the 1-D Poisson's equation based on the least square method and using the Silvaco Atlas simulation results and experimental data, respectively. Such a model can be adopted as a useful platform to develop the circuit simulator and provide the clear understanding of sDG MOSFET device physics.

  2. An analytical drain current model for symmetric double-gate MOSFETs

    Directory of Open Access Journals (Sweden)

    Fei Yu

    2018-04-01

    Full Text Available An analytical surface-potential-based drain current model of symmetric double-gate (sDG MOSFETs is described as a SPICE compatible model in this paper. The continuous surface and central potentials from the accumulation to the strong inversion regions are solved from the 1-D Poisson’s equation in sDG MOSFETs. Furthermore, the drain current is derived from the charge sheet model as a function of the surface potential. Over a wide range of terminal voltages, doping concentrations, and device geometries, the surface potential calculation scheme and drain current model are verified by solving the 1-D Poisson’s equation based on the least square method and using the Silvaco Atlas simulation results and experimental data, respectively. Such a model can be adopted as a useful platform to develop the circuit simulator and provide the clear understanding of sDG MOSFET device physics.

  3. Short-channel drain current model for asymmetric heavily/lightly ...

    Indian Academy of Sciences (India)

    The paper presents a drain current model for double gate metal oxide semiconductor field effect transistors (DG MOSFETs) based on a new velocity saturation model that accounts for short-channel velocity saturation effect independently in the front and the back gate controlled channels under asymmetric front and back ...

  4. A Drain Current Model Based on the Temperature Effect of a-Si:H Thin-Film Transistors

    International Nuclear Information System (INIS)

    Qiang Lei; Yao Ruo-He

    2012-01-01

    Based on the differential Ohm's law and Poisson's equation, an analytical model of the drain current for a-Si:H thin-film transistors is developed. This model is proposed to elaborate the temperature effect on the drain current, which indicates that the drain current is linear with temperature in the range of 290-360 K, and the results fit well with the experimental data

  5. Modeling the drain current and its equation parameters for lightly doped symmetrical double-gate MOSFETs

    International Nuclear Information System (INIS)

    Bhartia, Mini; Chatterjee, Arun Kumar

    2015-01-01

    A 2D model for the potential distribution in silicon film is derived for a symmetrical double gate MOSFET in weak inversion. This 2D potential distribution model is used to analytically derive an expression for the subthreshold slope and threshold voltage. A drain current model for lightly doped symmetrical DG MOSFETs is then presented by considering weak and strong inversion regions including short channel effects, series source to drain resistance and channel length modulation parameters. These derived models are compared with the simulation results of the SILVACO (Atlas) tool for different channel lengths and silicon film thicknesses. Lastly, the effect of the fixed oxide charge on the drain current model has been studied through simulation. It is observed that the obtained analytical models of symmetrical double gate MOSFETs are in good agreement with the simulated results for a channel length to silicon film thickness ratio greater than or equal to 2. (paper)

  6. Modeling the drain current and its equation parameters for lightly doped symmetrical double-gate MOSFETs

    Science.gov (United States)

    Bhartia, Mini; Chatterjee, Arun Kumar

    2015-04-01

    A 2D model for the potential distribution in silicon film is derived for a symmetrical double gate MOSFET in weak inversion. This 2D potential distribution model is used to analytically derive an expression for the subthreshold slope and threshold voltage. A drain current model for lightly doped symmetrical DG MOSFETs is then presented by considering weak and strong inversion regions including short channel effects, series source to drain resistance and channel length modulation parameters. These derived models are compared with the simulation results of the SILVACO (Atlas) tool for different channel lengths and silicon film thicknesses. Lastly, the effect of the fixed oxide charge on the drain current model has been studied through simulation. It is observed that the obtained analytical models of symmetrical double gate MOSFETs are in good agreement with the simulated results for a channel length to silicon film thickness ratio greater than or equal to 2.

  7. Analytical Model of Subthreshold Drain Current Characteristics of Ballistic Silicon Nanowire Transistors

    Directory of Open Access Journals (Sweden)

    Wanjie Xu

    2015-01-01

    Full Text Available A physically based subthreshold current model for silicon nanowire transistors working in the ballistic regime is developed. Based on the electric potential distribution obtained from a 2D Poisson equation and by performing some perturbation approximations for subband energy levels, an analytical model for the subthreshold drain current is obtained. The model is further used for predicting the subthreshold slopes and threshold voltages of the transistors. Our results agree well with TCAD simulation with different geometries and under different biasing conditions.

  8. Drain Current Modulation of a Single Drain MOSFET by Lorentz Force for Magnetic Sensing Application.

    Science.gov (United States)

    Chatterjee, Prasenjit; Chow, Hwang-Cherng; Feng, Wu-Shiung

    2016-08-30

    This paper reports a detailed analysis of the drain current modulation of a single-drain normal-gate n channel metal-oxide semiconductor field effect transistor (n-MOSFET) under an on-chip magnetic field. A single-drain n-MOSFET has been fabricated and placed in the center of a square-shaped metal loop which generates the on-chip magnetic field. The proposed device designed is much smaller in size with respect to the metal loop, which ensures that the generated magnetic field is approximately uniform. The change of drain current and change of bulk current per micron device width has been measured. The result shows that the difference drain current is about 145 µA for the maximum applied magnetic field. Such changes occur from the applied Lorentz force to push out the carriers from the channel. Based on the drain current difference, the change in effective mobility has been detected up to 4.227%. Furthermore, a detailed investigation reveals that the device behavior is quite different in subthreshold and saturation region. A change of 50.24 µA bulk current has also been measured. Finally, the device has been verified for use as a magnetic sensor with sensitivity 4.084% (29.6 T(-1)), which is very effective as compared to other previously reported works for a single device.

  9. Subthreshold Current and Swing Modeling of Gate Underlap DG MOSFETs with a Source/Drain Lateral Gaussian Doping Profile

    Science.gov (United States)

    Singh, Kunal; Kumar, Sanjay; Goel, Ekta; Singh, Balraj; Kumar, Mirgender; Dubey, Sarvesh; Jit, Satyabrata

    2017-01-01

    This paper proposes a new model for the subthreshold current and swing of the short-channel symmetric underlap ultrathin double gate metal oxide field effect transistors with a source/drain lateral Gaussian doping profile. The channel potential model already reported earlier has been utilized to formulate the closed form expression for the subthreshold current and swing of the device. The effects of the lateral straggle and geometrical parameters such as the channel length, channel thickness, and oxide thickness on the off current and subthreshold slope have been demonstrated. The devices with source/drain lateral Gaussian doping profiles in the underlap structure are observed to be highly resistant to short channel effects while improving the current drive. The proposed model is validated by comparing the results with the numerical simulation data obtained by using the commercially available ATLAS™, a two-dimensional (2-D) device simulator from SILVACO.

  10. Unified Drain Current Model of Armchair Graphene Nanoribbons with Uniaxial Strain and Quantum Effect

    Directory of Open Access Journals (Sweden)

    EngSiew Kang

    2014-01-01

    Full Text Available A unified current-voltage I-V model of uniaxial strained armchair graphene nanoribbons (AGNRs incorporating quantum confinement effects is presented in this paper. The I-V model is enhanced by integrating both linear and saturation regions into a unified and precise model of AGNRs. The derivation originates from energy dispersion throughout the entire Brillouin zone of uniaxial strained AGNRs based on the tight-binding approximation. Our results reveal the modification of the energy band gap, carrier density, and drain current upon strain. The effects of quantum confinement were investigated in terms of the quantum capacitance calculated from the broadening density of states. The results show that quantum effect is greatly dependent on the magnitude of applied strain, gate voltage, channel length, and oxide thickness. The discrepancies between the classical calculation and quantum calculation were also measured and it has been found to be as high as 19% drive current loss due to the quantum confinement. Our finding which is in good agreement with the published data provides significant insight into the device performance of uniaxial strained AGNRs in nanoelectronic applications.

  11. Effects of trap density on drain current LFN and its model development for E-mode GaN MOS-HEMT

    Science.gov (United States)

    Panda, D. K.; Lenka, T. R.

    2017-12-01

    In this paper the drain current low-frequency noise (LFN) of E-mode GaN MOS-HEMT is investigated for different gate insulators such as SiO2, Al2O3/Ga2O3/GdO3, HfO2/SiO2, La2O3/SiO2 and HfO2 with different trap densities by IFM based TCAD simulation. In order to analyze this an analytical model of drain current low frequency noise is developed. The model is developed by considering 2DEG carrier fluctuations, mobility fluctuations and the effects of 2DEG charge carrier fluctuations on the mobility. In the study of different gate insulators it is observed that carrier fluctuation is the dominant low frequency noise source and the non-uniform exponential distribution is critical to explain LFN behavior, so the analytical model is developed by considering uniform distribution of trap density. The model is validated with available experimental data from literature. The effect of total number of traps and gate length scaling on this low frequency noise due to different gate dielectrics is also investigated.

  12. The effect of random dopant fluctuation on threshold voltage and drain current variation in junctionless nanotransistors

    International Nuclear Information System (INIS)

    Rezapour, Arash; Rezapour, Pegah

    2015-01-01

    We investigate the effect of dopant random fluctuation on threshold voltage and drain current variation in a two-gate nanoscale transistor. We used a quantum-corrected technology computer aided design simulation to run the simulation (10000 randomizations). With this simulation, we could study the effects of varying the dimensions (length and width), and thicknesses of oxide and dopant factors of a transistor on the threshold voltage and drain current in subthreshold region (off) and overthreshold (on). It was found that in the subthreshold region the variability of the drain current and threshold voltage is relatively fixed while in the overthreshold region the variability of the threshold voltage and drain current decreases remarkably, despite the slight reduction of gate voltage diffusion (compared with that of the subthreshold). These results have been interpreted by using previously reported models for threshold current variability, load displacement, and simple analytical calculations. Scaling analysis shows that the variability of the characteristics of this semiconductor increases as the effects of the short channel increases. Therefore, with a slight increase of length and a reduction of width, oxide thickness, and dopant factor, we could correct the effect of the short channel. (paper)

  13. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    leakage from 'open to air' system or breakage of glass bottle (with associated risk to ... and an air-leak detection system. It is connected to a ... need to add water. Xpand chest drain: assessing equivalence to current standard therapy – a randomised controlled trial. CHARL COOPER, M.B. CH.B. TIMOTHY HARDCASTLE ...

  14. Viscosity-dependent drain current noise of AlGaN/GaN high electron mobility transistor in polar liquids

    International Nuclear Information System (INIS)

    Fang, J. Y.; Hsu, C. P.; Kang, Y. W.; Fang, K. C.; Kao, W. L.; Yao, D. J.; Chen, C. C.; Li, S. S.; Yeh, J. A.; Wang, Y. L.; Lee, G. Y.; Chyi, J. I.; Hsu, C. H.; Huang, Y. F.; Ren, F.

    2013-01-01

    The drain current fluctuation of ungated AlGaN/GaN high electron mobility transistors (HEMTs) measured in different fluids at a drain-source voltage of 0.5 V was investigated. The HEMTs with metal on the gate region showed good current stability in deionized water, while a large fluctuation in drain current was observed for HEMTs without gate metal. The fluctuation in drain current for the HEMTs without gate metal was observed and calculated as standard deviation from a real-time measurement in air, deionized water, ethanol, dimethyl sulfoxide, ethylene glycol, 1,2-butanediol, and glycerol. At room temperature, the fluctuation in drain current for the HEMTs without gate metal was found to be relevant to the dipole moment and the viscosity of the liquids. A liquid with a larger viscosity showed a smaller fluctuation in drain current. The viscosity-dependent fluctuation of the drain current was ascribed to the Brownian motions of the liquid molecules, which induced a variation in the surface dipole of the gate region. This study uncovers the causes of the fluctuation in drain current of HEMTs in fluids. The results show that the AlGaN/GaN HEMTs may be used as sensors to measure the viscosity of liquids within a certain range of viscosity

  15. Analytical Subthreshold Current and Subthreshold Swing Models for a Fully Depleted (FD) Recessed-Source/Drain (Re-S/D) SOI MOSFET with Back-Gate Control

    Science.gov (United States)

    Saramekala, Gopi Krishna; Tiwari, Pramod Kumar

    2017-08-01

    Two-dimensional (2D) analytical models for the subthreshold current and subthreshold swing of the back-gated fully depleted recessed-source/drain (Re-S/D) silicon-on-insulator (SOI) metal-oxide-semiconductor field-effect transistor (MOSFET) are presented. The surface potential is determined by solving the 2D Poisson equation in both channel and buried-oxide (BOX) regions, considering suitable boundary conditions. To derive closed-form expressions for the subthreshold characteristics, the virtual cathode potential expression has been derived in terms of the minimum of the front and back surface potentials. The effect of various device parameters such as gate oxide and Si film thicknesses, thickness of source/drain penetration into BOX, applied back-gate bias voltage, etc. on the subthreshold current and subthreshold swing has been analyzed. The validity of the proposed models is established using the Silvaco ATLAS™ 2D device simulator.

  16. Evapotranspiration from drained wetlands: drivers, modeling, storage functions, and restoration implications

    Science.gov (United States)

    Shukla, S.; Wu, C. L.; Shrestha, N.

    2017-12-01

    Abstract Evapotranspiration (ET) is a major component of wetland and watershed water budgets. The effect of wetland drainage on ET is not well understood. We tested whether the current understanding of insignificant effect of drainage on ET in the temperate region wetlands applies to those in the sub-tropics. Eddy covariance (EC) based ET measurements were made for two years at two previously drained and geographically close wetlands in the Everglades region of Florida. One wetland was significantly drained with 97% of its storage capacity lost. The other was a more functional wetland with 42% of storage capacity lost. Annual average ET at the significantly drained wetland was 836 mm, 34% less than the function wetland (1271 mm) and the difference was statistically significant (p = 0.001). Such differences in wetland ET in the same climatic region have not been observed. The difference in ET was mainly due to drainage driven differences in inundation and associated effects on net radiation (Rn) and local relative humidity. Two daily ET models, a regression (r2 = 0.80) and a Relevance Vector Machine (RVM) model (r2 = 0.84), were developed with the latter being more robust. These models, when used in conjunction with hydrologic models, improved ET predictions for drained wetlands. Predictions from an integrated model showed that more intensely drained wetlands at higher elevation should be targeted for restoration of downstream flows (flooding) because they have the ability to loose higher water volume through ET which increases available water storage capacity of wetlands. Daily ET models can predict changes in ET for improved evaluation of basin-scale effects of restoration programs and climate change scenarios.

  17. A drain current model for amorphous InGaZnO thin film transistors considering temperature effects

    Science.gov (United States)

    Cai, M. X.; Yao, R. H.

    2018-03-01

    Temperature dependent electrical characteristics of amorphous InGaZnO (a-IGZO) thin film transistors (TFTs) are investigated considering the percolation and multiple trapping and release (MTR) conduction mechanisms. Carrier-density and temperature dependent carrier mobility in a-IGZO is derived with the Boltzmann transport equation, which is affected by potential barriers above the conduction band edge with Gaussian-like distributions. The free and trapped charge densities in the channel are calculated with Fermi-Dirac statistics, and the field effective mobility of a-IGZO TFTs is then deduced based on the MTR theory. Temperature dependent drain current model for a-IGZO TFTs is finally derived with the obtained low field mobility and free charge density, which is applicable to both non-degenerate and degenerate conductions. This physical-based model is verified by available experiment results at various temperatures.

  18. Current practice patterns of drain usage amongst UK and Irish surgeons performing bilateral breast reductions: Evidence down the drain.

    Science.gov (United States)

    Sugrue, Conor M; McInerney, Niall; Joyce, Cormac W; Jones, Deidre; Hussey, Alan J; Kelly, Jack L; Kerin, Michael J; Regan, Padraic J

    2015-01-01

    Bilateral breast reduction (BBR) is one of the most frequently performed female breast operations. Despite no evidence supporting efficacy of drain usage in BBRs, postoperative insertion is common. Recent high quality evidence demonstrating potential harm from drain use has subsequently challenged this traditional practice. The aim of this study is to assess the current practice patterns of drains usage by Plastic & Reconstructive and Breast Surgeons in UK and Ireland performing BBRs. An 18 question survey was created evaluating various aspects of BBR practice. UK and Irish Plastic & Reconstructive and Breast Surgeons were invited to participate by an email containing a link to a web-based survey. Statistical analysis was performed with student t-test and chi-square test. Two hundred and eleven responding surgeons were analysed, including 80.1% (171/211) Plastic Surgeons and 18.9% (40/211) Breast Surgeons. Of the responding surgeons, 71.6% (151/211) routinely inserted postoperative drains, for a mean of 1.32 days. Drains were used significantly less by surgeons performing ≥20 BBRs (p = 0.02). With the majority of BBRs performed as an inpatient procedure, there was a trend towards less drain usage in surgeons performing this procedure as an outpatient; however, this was not statistically significant (p = 0.07). Even with the high level of evidence demonstrating the safety of BBR without drains, they are still routinely utilised. In an era of evidence- based medicine, surgeons performing breast reductions must adopt the results from scientific research into their clinical practice.

  19. Modeling drain current of indium zinc oxide thin film transistors prepared by solution deposition technique

    Science.gov (United States)

    Qiang, Lei; Liang, Xiaoci; Cai, Guangshuo; Pei, Yanli; Yao, Ruohe; Wang, Gang

    2018-06-01

    Indium zinc oxide (IZO) thin film transistor (TFT) deposited by solution method is of considerable technological interest as it is a key component for the fabrication of flexible and cheap transparent electronic devices. To obtain a principal understanding of physical properties of solution-processed IZO TFT, a new drain current model that account for the charge transport is proposed. The formulation is developed by incorporating the effect of gate voltage on mobility and threshold voltage with the carrier charges. It is demonstrated that in IZO TFTs the below threshold regime should be divided into two sections: EC - EF > 3kT and EC - EF ≤ 3kT, where kT is the thermal energy, EF and EC represent the Fermi level and the conduction band edge, respectively. Additionally, in order to describe conduction mechanisms more accurately, the extended mobility edge model is conjoined, which can also get rid of the complicated and lengthy computations. The good agreement between measured and calculated results confirms the efficiency of this model for the design of integrated large-area thin film circuits.

  20. Ionic screening effect on low-frequency drain current fluctuations in liquid-gated nanowire FETs

    International Nuclear Information System (INIS)

    Lu, Ming-Pei; Vire, Eric; Montès, Laurent

    2015-01-01

    The ionic screening effect plays an important role in determining the fundamental surface properties within liquid–semiconductor interfaces. In this study, we investigated the characteristics of low-frequency drain current noise in liquid-gated nanowire (NW) field effect transistors (FETs) to obtain physical insight into the effect of ionic screening on low-frequency current fluctuation. When the NW FET was operated close to the gate voltage corresponding to the maximum transconductance, the magnitude of the low-frequency noise for the NW exposed to a low-ionic-strength buffer (0.001 M) was approximately 70% greater than that when exposed to a high-ionic-strength buffer (0.1 M). We propose a noise model, considering the charge coupling efficiency associated with the screening competition between the electrolyte buffer and the NW, to describe the ionic screening effect on the low-frequency drain current noise in liquid-gated NW FET systems. This report not only provides a physical understanding of the ionic screening effect behind the low-frequency current noise in liquid-gated FETs but also offers useful information for developing the technology of NW FETs with liquid-gated architectures for application in bioelectronics, nanosensors, and hybrid nanoelectronics. (paper)

  1. Characteristics of drain-modulated generation current in n-type metal-oxide-semiconductor field-effect transistor

    International Nuclear Information System (INIS)

    Chen Hai-Feng; Guo Li-Xin; Zheng Pu-Yang; Dong Zhao; Zhang Qian

    2015-01-01

    Drain-modulated generation current I DMG induced by interface traps in an n-type metal-oxide-semiconductor field-effect transistor (nMOSFET) is investigated. The formation of I DMG ascribes to the change of the Si surface potential φ s . This change makes the channel suffer transformation from the inversion state, depletion I state to depletion II state. The simulation result agrees with the experiment in the inversion and depletion I states. In the depletion II state, the theoretical curve goes into saturation, while the experimental curve drops quickly as V D increases. The reason for this unconformity is that the drain-to-gate voltage V DG lessens φ s around the drain corner and controls the falling edge of the I DMG curve. The experiments of gate-modulated generation and recombination currents are also applied to verify the reasonability of the mechanism. Based on this mechanism, a theoretical model of the I DMG falling edge is set up in which I DMG has an exponential attenuation relation with V DG . Finally, the critical fitting coefficient t of the experimental curves is extracted. It is found that t = 80 mV = 3kT/q. This result fully shows the accuracy of the above mechanism. (paper)

  2. Generation of airborne Listeria innocua from model floor drains.

    Science.gov (United States)

    Berrang, Mark E; Frank, Joseph F

    2012-07-01

    Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.

  3. Predicting artificailly drained areas by means of selective model ensemble

    DEFF Research Database (Denmark)

    Møller, Anders Bjørn; Beucher, Amélie; Iversen, Bo Vangsø

    . The approaches employed include decision trees, discriminant analysis, regression models, neural networks and support vector machines amongst others. Several models are trained with each method, using variously the original soil covariates and principal components of the covariates. With a large ensemble...... out since the mid-19th century, and it has been estimated that half of the cultivated area is artificially drained (Olesen, 2009). A number of machine learning approaches can be used to predict artificially drained areas in geographic space. However, instead of choosing the most accurate model....... The study aims firstly to train a large number of models to predict the extent of artificially drained areas using various machine learning approaches. Secondly, the study will develop a method for selecting the models, which give a good prediction of artificially drained areas, when used in conjunction...

  4. Evapotranspiration from drained wetlands with different hydrologic regimes: Drivers, modeling, and storage functions

    Science.gov (United States)

    Wu, Chin-Lung; Shukla, Sanjay; Shrestha, Niroj K.

    2016-07-01

    We tested whether the current understanding of insignificant effect of drainage on evapotranspiration (ET) in the temperate region wetlands applies to those in the subtropics. Hydro-climatic drivers causing the changes in drained wetlands were identified and used to develop a generic model to predict wetland ET. Eddy covariance (EC)-based ET measurements were made for two years at two differently drained but close by wetlands, a heavily drained wetland (SW) (97% reduced surface storage) and a more functional wetland (DW) (42% reduced storage). Annual ET for more intensively drained SW was 836 mm, 34% less than DW (1271 mm) and the difference was significant (p = 0.001). This difference was mainly due to drainage driven differences in inundation and associated effects on net radiation (Rn) and local relative humidity. Two generic daily ET models, a regression model (MSE = 0.44 mm2, R2 = 0.80) and a machine learning-based Relevance Vector Machine (RVM) model (MSE = 0.36 mm2, R2 = 0.84), were developed with the latter being more robust. The RVM model can predict changes in ET for different restoration scenarios; a 1.1 m rise in drainage level showed 7% increase ET (18 mm) at SW while the increase at DW was negligible. The additional ET, 28% of surface flow, can enhance water storage, flood protection, and climate mitigation services at SW compared to DW. More intensely drained wetlands at higher elevation should be targeted for restoration for enhanced storage through increased ET. The models developed can predict changes in ET for improved evaluation of basin-scale effects of restoration programs and climate change scenarios.

  5. Analytical drain current formulation for gate dielectric engineered dual material gate-gate all around-tunneling field effect transistor

    Science.gov (United States)

    Madan, Jaya; Gupta, R. S.; Chaujar, Rishu

    2015-09-01

    In this work, an analytical drain current model for gate dielectric engineered (hetero dielectric)-dual material gate-gate all around tunnel field effect transistor (HD-DMG-GAA-TFET) has been developed. Parabolic approximation has been used to solve the two-dimensional (2D) Poisson equation with appropriate boundary conditions and continuity equations to evaluate analytical expressions for surface potential, electric field, tunneling barrier width and drain current. Further, the analog performance of the device is studied for three high-k dielectrics (Si3N4, HfO2, and ZrO2), and it has been investigated that the problem of lower ION, can be overcome by using the hetero-gate architecture. Moreover, the impact of scaling the gate oxide thickness and bias variations has also been studied. The HD-DMG-GAA-TFET shows an enhanced ION of the order of 10-4 A. The effectiveness of the proposed model is validated by comparing it with ATLAS device simulations.

  6. Cryogenic Fuel Tank Draining Analysis Model

    Science.gov (United States)

    Greer, Donald

    1999-01-01

    One of the technological challenges in designing advanced hypersonic aircraft and the next generation of spacecraft is developing reusable flight-weight cryogenic fuel tanks. As an aid in the design and analysis of these cryogenic tanks, a computational fluid dynamics (CFD) model has been developed specifically for the analysis of flow in a cryogenic fuel tank. This model employs the full set of Navier-Stokes equations, except that viscous dissipation is neglected in the energy equation. An explicit finite difference technique in two-dimensional generalized coordinates, approximated to second-order accuracy in both space and time is used. The stiffness resulting from the low Mach number is resolved by using artificial compressibility. The model simulates the transient, two-dimensional draining of a fuel tank cross section. To calculate the slosh wave dynamics the interface between the ullage gas and liquid fuel is modeled as a free surface. Then, experimental data for free convection inside a horizontal cylinder are compared with model results. Finally, cryogenic tank draining calculations are performed with three different wall heat fluxes to demonstrate the effect of wall heat flux on the internal tank flow field.

  7. Microdose Induced Drain Leakage Effects in Power Trench MOSFETs: Experiment and Modeling

    Science.gov (United States)

    Zebrev, Gennady I.; Vatuev, Alexander S.; Useinov, Rustem G.; Emeliyanov, Vladimir V.; Anashin, Vasily S.; Gorbunov, Maxim S.; Turin, Valentin O.; Yesenkov, Kirill A.

    2014-08-01

    We study experimentally and theoretically the micro-dose induced drain-source leakage current in the trench power MOSFETs under irradiation with high-LET heavy ions. We found experimentally that cumulative increase of leakage current occurs by means of stochastic spikes corresponding to a strike of single heavy ion into the MOSFET gate oxide. We simulate this effect with the proposed analytic model allowing to describe (including Monte Carlo methods) both the deterministic (cumulative dose) and stochastic (single event) aspects of the problem. Based on this model the survival probability assessment in space heavy ion environment with high LETs was proposed.

  8. A two dimensional analytical modeling of surface potential in triple metal gate (TMG) fully-depleted Recessed-Source/Drain (Re-S/D) SOI MOSFET

    Science.gov (United States)

    Priya, Anjali; Mishra, Ram Awadh

    2016-04-01

    In this paper, analytical modeling of surface potential is proposed for new Triple Metal Gate (TMG) fully depleted Recessed-Source/Dain Silicon On Insulator (SOI) Metal Oxide Semiconductor Field Effect Transistor (MOSFET). The metal with the highest work function is arranged near the source region and the lowest one near the drain. Since Recessed-Source/Drain SOI MOSFET has higher drain current as compared to conventional SOI MOSFET due to large source and drain region. The surface potential model developed by 2D Poisson's equation is verified by comparison to the simulation result of 2-dimensional ATLAS simulator. The model is compared with DMG and SMG devices and analysed for different device parameters. The ratio of metal gate length is varied to optimize the result.

  9. Current collapse modeling in AlGaN/GaN HEMT using small signal equivalent circuit for high power application

    Science.gov (United States)

    Nirmal, D.; Arivazhagan, L.; Fletcher, A. S. Augustine; Ajayan, J.; Prajoon, P.

    2018-01-01

    In this paper, the drain current collapse in AlGaN/GaN High Electron Mobility Transistor (HEMT) with field plate engineering is investigated. A small signal equivalent circuit of AlGaN/GaN HEMT is developed and a new drain current model is derived. This model is useful to correlate the impact of intrinsic capacitance and conductance on drain current collapse. The proposed device suppressed the current collapse phenomena by 10% compared with the conventional AlGaN/GaN HEMT. Moreover, the DC characteristics of the simulated device shows a drain current of 900 mA/mm, breakdown voltage of 291 V and transconductance of 175 mS/mm. Besides, the intrinsic capacitance and conductance parameters are extracted and its impact on drain current is analysed. Finally, the simulation results obtained were in compliance with the derived mathematical model of AlGaN/GaN HEMT.

  10. A mathematical model to optimize the drain phase in gravity-based peritoneal dialysis systems.

    Science.gov (United States)

    Akonur, Alp; Lo, Ying-Cheng; Cizman, Borut

    2010-01-01

    Use of patient-specific drain-phase parameters has previously been suggested to improve peritoneal dialysis (PD) adequacy. Improving management of the drain period may also help to minimize intraperitoneal volume (IPV). A typical gravity-based drain profile consists of a relatively constant initial fast-flow period, followed by a transition period and a decaying slow-flow period. That profile was modeled using the equation VD(t) = (V(D0) - Q(MAX) x t) xphi + (V(D0) x e(-alphat)) x (1 - phi), where V(D)(t) is the time-dependent dialysate volume; V(D0), the dialysate volume at the start of the drain; Q(MAX), the maximum drain flow rate; alpha, the exponential drain constant; and phi, the unit step function with respect to the flow transition. We simulated the effects of the assumed patient-specific maximum drain flow (Q(MAX)) and transition volume (psi), and the peritoneal volume percentage when transition occurs,for fixed device-specific drain parameters. Average patient transport parameters were assumed during 5-exchange therapy with 10 L of PD solution. Changes in therapy performance strongly depended on the drain parameters. Comparing 400 mL/85% with 200 mL/65% (Q(MAX/psi), drain time (7.5 min vs. 13.5 min) and IPV (2769 mL vs. 2355 mL) increased when the initial drain flow was low and the transition quick. Ultrafiltration and solute clearances remained relatively similar. Such differences were augmented up to a drain time of 22 minutes and an IPV of more than 3 L when Q(MAX) was 100 mL/min. The ability to model individual drain conditions together with water and solute transport may help to prevent patient discomfort with gravity-based PD. However, it is essential to note that practical difficulties such as displaced catheters and obstructed flow paths cause variability in drain characteristics even for the same patient, limiting the clinical applicability of this model.

  11. Centrifuge modelling of drained lateral pile - soil response

    DEFF Research Database (Denmark)

    Klinkvort, Rasmus Tofte

    of rigid piles. The tests have been performed in homogeneously dense dry or saturated Fontainebleau sand in order to mimic simplified drained offshore soil conditions. Approximately half of the tests have been carried out to investigate the centrifuge procedure in order to create a methodology of testing...... tests were used to investigate the pile - soil interaction to gain a better in-sight into the complex problem. A monotonic test series was carried out initially and then pile - soil interaction curves were deduced from these tests and compared with methodologies used today. The results indicate...... that the current methodologies can be improved and a modification to the methodology has been proposed. Secondly, a cyclic test series was carried out. The accumulation of displacement and the change in secant stiffness of the total response of these tests were evaluated. A simple mathematical model was proposed...

  12. On-current modeling of short-channel double-gate (DG) MOSFETs with a vertical Gaussian-like doping profile

    International Nuclear Information System (INIS)

    Dubey, Sarvesh; Jit, S.; Tiwari Pramod Kumar

    2013-01-01

    An analytic drain current model is presented for doped short-channel double-gate MOSFETs with a Gaussian-like doping profile in the vertical direction of the channel. The present model is valid in linear and saturation regions of device operation. The drain current variation with various device parameters has been demonstrated. The model is made more physical by incorporating the channel length modulation effect. Parameters like transconductance and drain conductance that are important in assessing the analog performance of the device have also been formulated. The model results are validated by numerical simulation results obtained by using the commercially available ATLAS™, a two dimensional device simulator from SILVACO. (semiconductor devices)

  13. Xpand chest drain: assessing equivalence to current standard ...

    African Journals Online (AJOL)

    The Xpand chest drain is an external medical device made of plastic that incorporates a fluid reservoir, a one-way valve and an air-leak detection system ... conect ed to a 2 000 ml drainage bag) prevents exposure of body fluids to nursing staff.

  14. Strip-drains for in situ clean up of contaminated fine-grained soils

    International Nuclear Information System (INIS)

    Bowders, J.J.; Gabr, M.A.

    1995-01-01

    Methods for in situ remediation of contaminated soils, such as bioremediation, vacuum/air stripping and soil flushing have been found to be less effective under fine-grained soil conditions. To enhance the performance of these techniques, it was proposed that strip-drains or wick drains also known as prefabricated vertical (PV) drains be used. The research objective was to determine the feasibility of using PV drains to enhance the soil flushing process. Bench top and intermediate-scale laboratory experiments were conducted. An overview of the work, results and future considerations were presented. Results indicated that the technology is feasible. A preliminary model for the technology to be used in any field situation was developed. The model is currently being tested with data from physical experiments on both intermediate and field tests. 5 figs

  15. Globalization, Brain Drain, and Development

    OpenAIRE

    Docquier, Frédéric; Rapoport, Hillel

    2012-01-01

    This paper reviews four decades of economics research on the brain drain, with a focus on recent contributions and on development issues. We first assess the magnitude, intensity, and determinants of the brain drain, showing that brain drain (or high-skill) migration is becoming a dominant pattern of international migration and a major aspect of globalization. We then use a stylized growth model to analyze the various channels through which a brain drain affects the sending countries and revi...

  16. Phosphorus modeling in tile drained agricultural systems using APEX

    Science.gov (United States)

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  17. Establishment and application of the estimation model for pollutant concentrfation in agriculture drain

    Science.gov (United States)

    Li, Qiangkun; Hu, Yawei; Jia, Qian; Song, Changji

    2018-02-01

    It is the key point of quantitative research on agricultural non-point source pollution load, the estimation of pollutant concentration in agricultural drain. In the guidance of uncertainty theory, the synthesis of fertilization and irrigation is used as an impulse input to the farmland, meanwhile, the pollutant concentration in agricultural drain is looked as the response process corresponding to the impulse input. The migration and transformation of pollutant in soil is expressed by Inverse Gaussian Probability Density Function. The law of pollutants migration and transformation in soil at crop different growth periods is reflected by adjusting parameters of Inverse Gaussian Distribution. Based on above, the estimation model for pollutant concentration in agricultural drain at field scale was constructed. Taking the of Qing Tong Xia Irrigation District in Ningxia as an example, the concentration of nitrate nitrogen and total phosphorus in agricultural drain was simulated by this model. The results show that the simulated results accorded with measured data approximately and Nash-Sutcliffe coefficients were 0.972 and 0.964, respectively.

  18. Importance of including small-scale tile drain discharge in the calibration of a coupled groundwater-surface water catchment model

    DEFF Research Database (Denmark)

    Hansen, Anne Lausten; Refsgaard, Jens Christian; Christensen, Britt Stenhøj Baun

    2013-01-01

    the catchment. In this study, a coupled groundwater-surface water model based on the MIKE SHE code was developed for the 4.7 km2 Lillebæk catchment in Denmark, where tile drain flow is a major contributor to the stream discharge. The catchment model was calibrated in several steps by incrementally including...... the observation data into the calibration to see the effect on model performance of including diverse data types, especially tile drain discharge. For the Lillebæk catchment, measurements of hydraulic head, daily stream discharge, and daily tile drain discharge from five small (1–4 ha) drainage areas exist....... The results showed that including tile drain data in the calibration of the catchment model improved its general performance for hydraulic heads and stream discharges. However, the model failed to correctly describe the local-scale dynamics of the tile drain discharges, and, furthermore, including the drain...

  19. Americium/curium bushing melter drain tests

    International Nuclear Information System (INIS)

    Smith, M.E.; Hardy, B.J.; Smith, M.E.

    1997-01-01

    Americium and curium were produced in the past at the Savannah River Site (SRS) for research, medical, and radiological applications. They have been stored in a nitric acid solution in an SRS reprocessing facility for a number of years. Vitrification of the americium/curium (Am/Cm) solution will allow the material to be safely stored or transported to the DOE Oak Ridge Reservation. Oak Ridge is responsible for marketing radionuclides for research and medical applications. The bushing melter technology being used in the Am/Cm vitrification research work is also under consideration for the stabilization of other actinides such as neptunium and plutonium. A series of melter drain tests were conducted at the Savannah River Technology Center to determine the relationship between the drain tube assembly operating variables and the resulting pour initiation times, glass flowrates, drain tube temperatures, and stop pour times. Performance criteria such as ability to start and stop pours in a controlled manner were also evaluated. The tests were also intended to provide support of oil modeling of drain tube performance predictions and thermal modeling of the drain tube and drain tube heater assembly. These drain tests were instrumental in the design of subsequent melter drain tube and drain tube heaters for the Am/Cm bushing melter, and therefore in the success of the Am/Cm vitrification and plutonium immobilization programs

  20. Circuital model for the spherical geodesic waveguide perfect drain

    Science.gov (United States)

    González, Juan C.; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan C.

    2012-08-01

    The perfect drain for the Maxwell fish eye (MFE) is a non-magnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity that depends on frequency. However, this material is only a theoretical material, so it cannot be used in practical devices. The perfect drain has been claimed as necessary for achieving super-resolution (Leonhardt 2009 New J. Phys. 11 093040), which has increased the interest in practical perfect drains suitable for manufacturing. Here, we present a practical perfect drain that is designed using a simple circuit (made of a resistance and a capacitor) connected to the coaxial line. Moreover, we analyze the super-resolution properties of a device equivalent to the MFE, known as a spherical geodesic waveguide, loaded with this perfect drain. The super-resolution analysis for this device is carried out using COMSOL Multiphysics. The results of simulations predict a super-resolution of up to λ/3000.

  1. Circuital model for the spherical geodesic waveguide perfect drain

    International Nuclear Information System (INIS)

    González, Juan C; Grabovičkić, Dejan; Benítez, Pablo; Miñano, Juan C

    2012-01-01

    The perfect drain for the Maxwell fish eye (MFE) is a non-magnetic dissipative region placed in the focal point to absorb all the incident radiation without reflection or scattering. The perfect drain was recently designed as a material with complex permittivity that depends on frequency. However, this material is only a theoretical material, so it cannot be used in practical devices. The perfect drain has been claimed as necessary for achieving super-resolution (Leonhardt 2009 New J. Phys. 11 093040), which has increased the interest in practical perfect drains suitable for manufacturing. Here, we present a practical perfect drain that is designed using a simple circuit (made of a resistance and a capacitor) connected to the coaxial line. Moreover, we analyze the super-resolution properties of a device equivalent to the MFE, known as a spherical geodesic waveguide, loaded with this perfect drain. The super-resolution analysis for this device is carried out using COMSOL Multiphysics. The results of simulations predict a super-resolution of up to λ/3000. (paper)

  2. High-current and low acceleration voltage arsenic ion implanted polysilicon-gate and source-drain electrode Si mos transistor

    International Nuclear Information System (INIS)

    Saito, Yasuyuki; Sugimura, Yoshiro; Sugihara, Michiyuki

    1993-01-01

    The fabrication process of high current arsenic (As) ion implanted polysilicon (Si) gate and source drain (SD) electrode Si n-channel metal oxide-semiconductor field effect transistor (MOSFET) was examined. Poly Si film n-type doping was performed by using high current (typical current: 2mA) and relatively low acceleration voltage (40keV) As ion implantation technique (Lintott series 3). It was observed that high dose As implanted poly Si films as is show refractoriness against radical fluorine excited by microwave. Using GCA MANN4800 (m/c ID No.2, resist: OFPR) mask pattern printing technique, the high current As ion implantation technique and radical fluorine gas phase etching (Chemical dry etching: CDE) technique, the n-channel Poly Si gate (ρs = ≅100Ω/□) enhancement MQSFETs(ρs source drain = ≅50Ω/□, SiO 2 gate=380 angstrom) with off-leak-less were obtained on 3 inch Czochralski grown 2Ωcm boron doped p type wafers (Osaka titanium). By the same process, a 8 bit single chip μ-processor with 26MHz full operation was performed

  3. Gate voltage and drain current stress instabilities in amorphous In–Ga–Zn–O thin-film transistors with an asymmetric graphene electrode

    Directory of Open Access Journals (Sweden)

    Joonwoo Kim

    2015-09-01

    Full Text Available The gate voltage and drain current stress instabilities in amorphous In–Ga–Zn–O thin-film transistors (a-IGZO TFTs having an asymmetric graphene electrode structure are studied. A large positive shift in the threshold voltage, which is well fitted to a stretched-exponential equation, and an increase in the subthreshold slope are observed when drain current stress is applied. This is due to an increase in temperature caused by power dissipation in the graphene/a-IGZO contact region, in addition to the channel region, which is different from the behavior in a-IGZO TFTs with a conventional transparent electrode.

  4. Development and testing of watershed-scale models for poorly drained soils

    Science.gov (United States)

    Glenn P. Fernandez; George M. Chescheir; R. Wayne Skaggs; Devendra M. Amatya

    2005-01-01

    Watershed-scale hydrology and water quality models were used to evaluate the crrmulative impacts of land use and management practices on dowrzstream hydrology and nitrogen loading of poorly drained watersheds. Field-scale hydrology and nutrient dyyrutmics are predicted by DRAINMOD in both models. In the first model (DRAINMOD-DUFLOW), field-scale predictions are coupled...

  5. Modelling of the draining of a molten glass heated by induction

    International Nuclear Information System (INIS)

    Lima-Da-Silva, Marcio

    2014-01-01

    This thesis is part of the development of a new technology of oxides melting in a furnace heated by induction. The technology studied involves strong interactions between electromagnetic, thermal and hydrodynamic phenomena in a flow with physical properties strongly dependents of the temperature. The aim of the thesis is the modelling of the process by coupling closely the Joule heating, the mechanical stirring and the draining of the furnace. The modeling of the time evolution of the interface between glass and air during the emptying of the cold crucible was performed. Regarding the methodology, we chose to combine two scientific codes: Flux for the electromagnetic calculation and Fluent for thermal-hydraulics. The evolution of the free surface was treated by the multiphasic method 'Volume-Of-Fluid - VOF' and the mechanical stirring by the 'Moving Reference Frame' and the 'Sliding Mesh'. First of all, we considered the draining of a tank filled with a silicon oil of high-viscosity without mechanical stirring. This initial model took into account studies of hydraulic similarity between the silicon oil and the glass. Then we superimposed the forced flow creates by the mechanical stirrer, the thermal and the electromagnetic phenomena in order to model the flow of the molten glass. The final model can provide various parameters, including the time needed to drain the furnace, the heat transfer flux and the time evolution of the mass flow rate and of the temperature inside de furnace. (author) [fr

  6. An analytical charge-based drain current model for nano-scale In0.52Al0.48As–In0.53Ga0.47 as a separated double-gate HEMT

    International Nuclear Information System (INIS)

    Rathi, Servin; Gupta, Mridula; Gupta, R S; Jogi, Jyotika

    2010-01-01

    In this paper, a two-dimensional electron gas (2DEG) charge-control model for carrier density in the channel is developed for a separated double-gate high-electron-mobility transistor. The model is extended to calculate I d –V g characteristics of the device. The drain current model uses a polynomial dependence of sheet carrier concentration on the position of a quasi-Fermi energy level to predict the modulation of back carrier concentration due to a front gate bias. The characteristics are investigated for various channel thicknesses and delta doping concentrations in order to study the effect of the back gate on the overall device performance. The analytical results so obtained are verified by comparing them with simulated and experimental results. A good agreement between the results is obtained, thus validating the model

  7. Effect of drain current on appearance probability and amplitude of random telegraph noise in low-noise CMOS image sensors

    Science.gov (United States)

    Ichino, Shinya; Mawaki, Takezo; Teramoto, Akinobu; Kuroda, Rihito; Park, Hyeonwoo; Wakashima, Shunichi; Goto, Tetsuya; Suwa, Tomoyuki; Sugawa, Shigetoshi

    2018-04-01

    Random telegraph noise (RTN), which occurs in in-pixel source follower (SF) transistors, has become one of the most critical problems in high-sensitivity CMOS image sensors (CIS) because it is a limiting factor of dark random noise. In this paper, the behaviors of RTN toward changes in SF drain current conditions were analyzed using a low-noise array test circuit measurement system with a floor noise of 35 µV rms. In addition to statistical analysis by measuring a large number of transistors (18048 transistors), we also analyzed the behaviors of RTN parameters such as amplitude and time constants in the individual transistors. It is demonstrated that the appearance probability of RTN becomes small under a small drain current condition, although large-amplitude RTN tends to appear in a very small number of cells.

  8. Drain site evisceration of fallopian tube, another reason to discourage abdominal drain: report of a case and brief review of literature.

    Science.gov (United States)

    Saini, Pradeep; Faridi, M S; Agarwal, Nitin; Gupta, Arun; Kaur, Navneet

    2012-04-01

    Placement of a drain following abdominal surgery is common despite a lack of convincing evidence in the current literature to support this practice. The use of intra-abdominal drain is associated with many potential and serious complications. We report a drain site evisceration of the right fallopian tube after the removal of an intra-abdominal drain. The drain was placed in the right iliac fossa in a patient who underwent a lower segment Caesarean section (LSCS) for meconium liquor with fetal distress. The Pfannenstiel incision made for LSCS was reopened and the protruding inflamed fimbrial end of the right fallopian tube was excised. The patient made an uneventful recovery. Routine intra-abdominal prophylactic drain following an abdominal surgery including LSCS should be discouraged.

  9. Modeling and risk assessment of a 30-Year-old subsurface radioactive-liquid drain field

    Science.gov (United States)

    Dawson, Lon A.; Pohl, Phillip I.

    1997-11-01

    The contamination from a 30-year-old radioactive liquid drain field was assessed for movement in the subsurface and potential risks to humans. This assessment included determining field concentrations of cesium 137 (137Cs) and other inorganic contaminants and modeling of the flow and transport of the liquid waste that was sent to the drain field. The field investigation detected no contamination deeper than 15 feet (4.6 m) from the bottom of the drain field. Prediction of the water content of the vadose zone showed no saturated conditions for times greater than 10 years after the known infiltration. Sensitivity analysis of the modeling parameters showed the equilibrium sorption coefficient to be the most important factor in predicting the contaminant plumes. Calibration of modeling results with field data gave a 137Cs sorption coefficient that is within the range of values found in the literature. The risk assessment for the site showed that the contamination poses no significant risk to human health.

  10. Drains and Drainage Capabilities: Quantitative Analysis of Drain Efficiencies

    Directory of Open Access Journals (Sweden)

    Andaç Aykan

    2016-03-01

    Full Text Available Objective: In this study, it was aimed to compare the efficiency of the same type of but different-sized silicone drains at different surgical procedures. Material and Methods: Twenty-four patients, who had different diagnoses and were operated between 2011 and 2013, were included. In all patients, 7- and 10-mm silicone-ended, Jackson–Pratt drains were used. Drains that were under 30 cc/day removed. The connection tube and perforated silicone end were examined due to the clot content. All drain efficiencies were calculated, and the results were statistically analyzed. Results: Seven of the 24 patients (29.2% were males and 17 (70.8% were females; the mean age was 39.0±11.4 years. Totally, 49 drains were used, of which 25 (51% were 7 mm and 24 (49% were 10 mm in size. Median removal time was the 5th day (2–12 for the 7-mm drains and the 6th day (3–14 for the 10-mm drains. There was no statistically significant difference between the groups for drain removal time (p=0.268. Further, there was no difference at the connection tube and silicone end for clot content between the 7- and 10-mm drains (p=0.58. For the drainage volume and efficiency, no difference was observed between the groups (p=0.146. Conclusion: In this study it was observed that there is no difference in the drainage volume and efficiency between different-sized Jackson–Pratt drains.

  11. Globalization and migration: A "unified brain drain" model

    OpenAIRE

    Brezis, Elise S.; Soueri, Ariel

    2012-01-01

    Globalization has led to a vast flow of migration of workers but also of students. The purpose of this paper is to analyze the migration of individuals encompassing decisions already at the level of education. We develop a unified brain drain model that incorporates the decisions of an individual vis - à - vis both education and migration. In the empirical part, this paper addresses international flows of migration within the EU and presents strong evidence of concentration of students in cou...

  12. Analyzing subsurface drain network performance in an agricultural monitoring site with a three-dimensional hydrological model

    Science.gov (United States)

    Nousiainen, Riikka; Warsta, Lassi; Turunen, Mika; Huitu, Hanna; Koivusalo, Harri; Pesonen, Liisa

    2015-10-01

    Effectiveness of a subsurface drainage system decreases with time, leading to a need to restore the drainage efficiency by installing new drain pipes in problem areas. The drainage performance of the resulting system varies spatially and complicates runoff and nutrient load generation within the fields. We presented a method to estimate the drainage performance of a heterogeneous subsurface drainage system by simulating the area with the three-dimensional hydrological FLUSH model. A GIS analysis was used to delineate the surface runoff contributing area in the field. We applied the method to reproduce the water balance and to investigate the effectiveness of a subsurface drainage network of a clayey field located in southern Finland. The subsurface drainage system was originally installed in the area in 1971 and the drainage efficiency was improved in 1995 and 2005 by installing new drains. FLUSH was calibrated against total runoff and drain discharge data from 2010 to 2011 and validated against total runoff in 2012. The model supported quantification of runoff fractions via the three installed drainage networks. Model realisations were produced to investigate the extent of the runoff contributing areas and the effect of the drainage parameters on subsurface drain discharge. The analysis showed that better model performance was achieved when the efficiency of the oldest drainage network (installed in 1971) was decreased. Our analysis method can reveal the drainage system performance but not the reason for the deterioration of the drainage performance. Tillage layer runoff from the field was originally computed by subtracting drain discharge from the total runoff. The drains installed in 1995 bypass the measurement system, which renders the tillage layer runoff calculation procedure invalid after 1995. Therefore, this article suggests use of a local correction coefficient based on the simulations for further research utilizing data from the study area.

  13. Prediction of phosphorus loads in an artificially drained lowland catchment using a modified SWAT model

    Science.gov (United States)

    Bauwe, Andreas; Eckhardt, Kai-Uwe; Lennartz, Bernd

    2017-04-01

    Eutrophication is still one of the main environmental problems in the Baltic Sea. Currently, agricultural diffuse sources constitute the major portion of phosphorus (P) fluxes to the Baltic Sea and have to be reduced to achieve the HELCOM targets and improve the ecological status. Eco-hydrological models are suitable tools to identify sources of nutrients and possible measures aiming at reducing nutrient loads into surface waters. In this study, the Soil and Water Assessment Tool (SWAT) was applied to the Warnow river basin (3300 km2), the second largest watershed in Germany discharging into the Baltic Sea. The Warnow river basin is located in northeastern Germany and characterized by lowlands with a high proportion of artificially drained areas. The aim of this study were (i) to estimate P loadings for individual flow fractions (point sources, surface runoff, tile flow, groundwater flow), spatially distributed on sub-basin scale. Since the official version of SWAT does not allow for the modeling of P in tile drains, we tested (ii) two different approaches of simulating P in tile drains by changing the SWAT source code. The SWAT source code was modified so that (i) the soluble P concentration of the groundwater was transferred to the tile water and (ii) the soluble P in the soil was transferred to the tiles. The SWAT model was first calibrated (2002-2011) and validated (1992-2001) for stream flow at 7 headwater catchments at a daily time scale. Based on this, the stream flow at the outlet of the Warnow river basin was simulated. Performance statistics indicated at least satisfactory model results for each sub-basin. Breaking down the discharge into flow constituents, it becomes visible that stream flow is mainly governed by groundwater and tile flow. Due to the topographic situation with gentle slopes, surface runoff played only a minor role. Results further indicate that the prediction of soluble P loads was improved by the modified SWAT versions. Major sources of

  14. Effects of pond draining on biodiversity and water quality of farm ponds.

    Science.gov (United States)

    Usio, Nisikawa; Imada, Miho; Nakagawa, Megumi; Akasaka, Munemitsu; Takamura, Noriko

    2013-12-01

    Farm ponds have high conservation value because they contribute significantly to regional biodiversity and ecosystem services. In Japan pond draining is a traditional management method that is widely believed to improve water quality and eradicate invasive fish. In addition, fishing by means of pond draining has significant cultural value for local people, serving as a social event. However, there is a widespread belief that pond draining reduces freshwater biodiversity through the extirpation of aquatic animals, but scientific evaluation of the effectiveness of pond draining is lacking. We conducted a large-scale field study to evaluate the effects of pond draining on invasive animal control, water quality, and aquatic biodiversity relative to different pond-management practices, pond physicochemistry, and surrounding land use. The results of boosted regression-tree models and analyses of similarity showed that pond draining had little effect on invasive fish control, water quality, or aquatic biodiversity. Draining even facilitated the colonization of farm ponds by invasive red swamp crayfish (Procambarus clarkii), which in turn may have detrimental effects on the biodiversity and water quality of farm ponds. Our results highlight the need for reconsidering current pond management and developing management plans with respect to multifunctionality of such ponds. Efectos del Drenado de Estanques sobre la Biodiversidad y la Calidad del Agua en Estanques de Cultivo. © 2013 Society for Conservation Biology.

  15. An Equal-Strain Analytical Solution for the Radial Consolidation of Unsaturated Soils by Vertical Drains considering Drain Resistance

    Directory of Open Access Journals (Sweden)

    Feng Zhou

    2018-01-01

    Full Text Available Developing an analytical solution for the consolidation of unsaturated soils remains a challenging task due to the complexity of coupled governing equations for air and water phases. This paper presents an equal-strain model for the radial consolidation of unsaturated soils by vertical drains, and the effect of drain resistance is also considered. Simplified governing equations are established, and an analytical solution to calculate the excess pore-air and pore-water pressures is derived by using the methods of matrix analysis and eigenfunction expansion. The average degrees of consolidation for air and water phases and the ground surface settlement are also given. The solutions of the equal-strain model are verified by comparing the proposed free-strain model with the equal-strain model, and reasonably good agreement is obtained. Moreover, parametric studies regarding the drain resistance effect are graphically presented.

  16. Influence of microstructure in current draining efficiency in magnesium sacrificial anodes

    International Nuclear Information System (INIS)

    Robles P, E.F.

    1994-01-01

    In the last few years the efficiency of magnesium anodes used as cathodic protection of structures and metallic components, has presented outstanding variations. In spite of the fulfillment with the standard of chemicomposition, the working efficiency is low, existing the possibility that this be own to microstructural variations still not studied. For this reason, in the present work are shown some experiences with solidification of magnesium, in order to observe the influence of the structure of casting in the efficiency of current drain. For this purpose, pure magnesium (99.98%) was melt in graphite crucibles using protecting flux, pouring then in three different moulds: graphite, steel and aluminium, this last supplied with refrigeration using water as coolant up till now, the attained structures does not exert a determinant influence in the efficiency of magnesium anodes, and for this reason it is recommended to carry out thermomechanical treatments to continue with the study. (Author)

  17. Modeling the effects of tile drain placement on the hydrologic function of farmed prairie wetlands

    Science.gov (United States)

    Werner, Brett; Tracy, John; Johnson, W. Carter; Voldseth, Richard A.; Guntenspergen, Glenn R.; Millett, Bruce

    2016-01-01

    The early 2000s saw large increases in agricultural tile drainage in the eastern Dakotas of North America. Agricultural practices that drain wetlands directly are sometimes limited by wetland protection programs. Little is known about the impacts of tile drainage beyond the delineated boundaries of wetlands in upland catchments that may be in agricultural production. A series of experiments were conducted using the well-published model WETLANDSCAPE that revealed the potential for wetlands to have significantly shortened surface water inundation periods and lower mean depths when tile is placed in certain locations beyond the wetland boundary. Under the soil conditions found in agricultural areas of South Dakota in North America, wetland hydroperiod was found to be more sensitive to the depth that drain tile is installed relative to the bottom of the wetland basin than to distance-based setbacks. Because tile drainage can change the hydrologic conditions of wetlands, even when deployed in upland catchments, tile drainage plans should be evaluated more closely for the potential impacts they might have on the ecological services that these wetlands currently provide. Future research should investigate further how drainage impacts are affected by climate variability and change.

  18. Test of a simplified modeling approach for nitrogen transfer in agricultural subsurface-drained catchments

    Science.gov (United States)

    Henine, Hocine; Julien, Tournebize; Jaan, Pärn; Ülo, Mander

    2017-04-01

    In agricultural areas, nitrogen (N) pollution load to surface waters depends on land use, agricultural practices, harvested N output, as well as the hydrology and climate of the catchment. Most of N transfer models need to use large complex data sets, which are generally difficult to collect at larger scale (>km2). The main objective of this study is to carry out a hydrological and a geochemistry modeling by using a simplified data set (land use/crop, fertilizer input, N losses from plots). The modelling approach was tested in the subsurface-drained Orgeval catchment (Paris Basin, France) based on following assumptions: Subsurface tile drains are considered as a giant lysimeter system. N concentration in drain outlets is representative for agricultural practices upstream. Analysis of observed N load (90% of total N) shows 62% of export during the winter. We considered prewinter nitrate (NO3) pool (PWNP) in soils at the beginning of hydrological drainage season as a driving factor for N losses. PWNP results from the part of NO3 not used by crops or the mineralization part of organic matter during the preceding summer and autumn. Considering these assumptions, we used PWNP as simplified input data for the modelling of N transport. Thus, NO3 losses are mainly influenced by the denitrification capacity of soils and stream water. The well-known HYPE model was used to perform water and N losses modelling. The hydrological simulation was calibrated with the observation data at different sub-catchments. We performed a hydrograph separation validated on the thermal and isotopic tracer studies and the general knowledge of the behavior of Orgeval catchment. Our results show a good correlation between the model and the observations (a Nash-Sutcliffe coefficient of 0.75 for water discharge and 0.7 for N flux). Likewise, comparison of calibrated PWNP values with the results from a field survey (annual PWNP campaign) showed significant positive correlation. One can conclude that

  19. Advances in chest drain management in thoracic disease

    Science.gov (United States)

    George, Robert S.

    2016-01-01

    An adequate chest drainage system aims to drain fluid and air and restore the negative pleural pressure facilitating lung expansion. In thoracic surgery the post-operative use of the conventional underwater seal chest drainage system fulfills these requirements, however they allow great variability amongst practices. In addition they do not offer accurate data and they are often inconvenient to both patients and hospital staff. This article aims to simplify the myths surrounding the management of chest drains following chest surgery, review current experience and explore the advantages of modern digital chest drain systems and address their disease-specific use. PMID:26941971

  20. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  1. State of science of phosphorus modeling in tile drained agricultural systems using APEX

    Science.gov (United States)

    Phosphorus losses through tile drained systems in agricultural landscapes may be causing the persistent eutrophication problems observed in surface water. The purpose of this paper is to evaluate the state of the science in the Agricultural Policy/Environmental eXtender (APEX) model related to surf...

  2. Drain current enhancement induced by hole injection from gate of 600-V-class normally off gate injection transistor under high temperature conditions up to 200 °C

    Science.gov (United States)

    Ishii, Hajime; Ueno, Hiroaki; Ueda, Tetsuzo; Endoh, Tetsuo

    2018-06-01

    In this paper, the current–voltage (I–V) characteristics of a 600-V-class normally off GaN gate injection transistor (GIT) from 25 to 200 °C are analyzed, and it is revealed that the drain current of the GIT increases during high-temperature operation. It is found that the maximum drain current (I dmax) of the GIT is 86% higher than that of a conventional 600-V-class normally off GaN metal insulator semiconductor hetero-FET (MIS-HFET) at 150 °C, whereas the GIT obtains 56% I dmax even at 200 °C. Moreover, the mechanism of the drain current increase of the GIT is clarified by examining the relationship between the temperature dependence of the I–V characteristics of the GIT and the gate hole injection effect determined from the shift of the second transconductance (g m) peak of the g m–V g characteristic. From the above, the GIT is a promising device with enough drivability for future power switching applications even under high-temperature conditions.

  3. PWSCC Potential on the Drain Tubes of WEC Model 51F Steam Generators in Domestic Plants

    International Nuclear Information System (INIS)

    Chang, B. I.; Song, M. S.; Yoon, K. S.; Kim, I. Y.

    2009-01-01

    The drain couplings of Westinghouse Model 51F steam generators that had been operated in the domestic Nuclear Power Plants were modified and repaired in accordance with the corrective action of replacing the existing Alloy 600 weld build-up with Alloy 690(Alloy 52/152) weld build-up in order to increase its resistance to primary water stress corrosion cracking (PWSCC). The drain tube made of alloy 600, however, was not replaced and left susceptible to the PWSCC. Among the environmental, metallurgical and mechanical factors controlling a susceptibility to the PWSCC, it is believed that tensile stresses play an important role. The objective of this study is to conservatively estimate stress state of the drain tube during fabrication and when exposed to normal plant operations, and to investigate its potential for the PWSCC

  4. Analytical model of nanoscale junctionless transistors towards controlling of short channel effects through source/drain underlap and channel thickness engineering

    Science.gov (United States)

    Roy, Debapriya; Biswas, Abhijit

    2018-01-01

    We develop a 2D analytical subthreshold model for nanoscale double-gate junctionless transistors (DGJLTs) with gate-source/drain underlap. The model is validated using well-calibrated TCAD simulation deck obtained by comparing experimental data in the literature. To analyze and control short-channel effects, we calculate the threshold voltage, drain induced barrier lowering (DIBL) and subthreshold swing of DGJLTs using our model and compare them with corresponding simulation value at channel length of 20 nm with channel thickness tSi ranging 5-10 nm, gate-source/drain underlap (LSD) values 0-7 nm and source/drain doping concentrations (NSD) ranging 5-12 × 1018 cm-3. As tSi reduces from 10 to 5 nm DIBL drops down from 42.5 to 0.42 mV/V at NSD = 1019 cm-3 and LSD = 5 nm in contrast to decrement from 71 to 4.57 mV/V without underlap. For a lower tSiDIBL increases marginally with increasing NSD. The subthreshold swing reduces more rapidly with thinning of channel thickness rather than increasing LSD or decreasing NSD.

  5. Improved simulation of poorly drained forests using Biome-BGC.

    Science.gov (United States)

    Bond-Lamberty, Ben; Gower, Stith T; Ahl, Douglas E

    2007-05-01

    Forested wetlands and peatlands are important in boreal and terrestrial biogeochemical cycling, but most general-purpose forest process models are designed and parameterized for upland systems. We describe changes made to Biome-BGC, an ecophysiological process model, that improve its ability to simulate poorly drained forests. Model changes allowed for: (1) lateral water inflow from a surrounding watershed, and variable surface and subsurface drainage; (2) adverse effects of anoxic soil on decomposition and nutrient mineralization; (3) closure of leaf stomata in flooded soils; and (4) growth of nonvascular plants (i.e., bryophytes). Bryophytes were treated as ectohydric broadleaf evergreen plants with zero stomatal conductance, whose cuticular conductance to CO(2) was dependent on plant water content. Individual model changes were parameterized with published data, and ecosystem-level model performance was assessed by comparing simulated output to field data from the northern BOREAS site in Manitoba, Canada. The simulation of the poorly drained forest model exhibited reduced decomposition and vascular plant growth (-90%) compared with that of the well-drained forest model; the integrated bryophyte photosynthetic response accorded well with published data. Simulated net primary production, biomass and soil carbon accumulation broadly agreed with field measurements, although simulated net primary production was higher than observed data in well-drained stands. Simulated net primary production in the poorly drained forest was most sensitive to oxygen restriction on soil processes, and secondarily to stomatal closure in flooded conditions. The modified Biome-BGC remains unable to simulate true wetlands that are subject to prolonged flooding, because it does not track organic soil formation, water table changes, soil redox potential or anaerobic processes.

  6. The effects of drain scatterings on the electron transport properties of strained-Si diodes with ballistic and non-ballistic channels

    International Nuclear Information System (INIS)

    Yasenjan Ghupur; Mamtimin Geni; Mamatrishat Mamat; Abudukelimu Abudureheman

    2015-01-01

    The effects of multiple scattering on the electron transport properties in drain regions are numerically investigated for the cases of strained-Si diodes with or without scattering in the channel. The performance of non-ballistic (with scattering) channel Si-diodes is compared with that of ballistic (without scattering) channel Si-diodes, using the strain and scattering model. Our results show that the values of the electron velocity and the current in the strain model are higher than the respective values in the unstrained model, and the values of the velocity and the current in the ballistic channel model are higher than the respective values in the non-ballistic channel model. In the strain and scattering models, the effect of each carrier scattering mechanism on the performance of the Si-diodes is analyzed in the drain region. For the ballistic channel model, our results show that inter-valley optical phonon scattering improves device performance, whereas intra-valley acoustic phonon scattering degrades device performance. For the strain model, our results imply that the larger energy splitting of the strained Si could suppress the inter-valley phonon scattering rate. In conclusion, for the drain region, investigation of the strained-Si and scattering mechanisms are necessary, in order to improve the performance of nanoscale ballistic regime devices. (paper)

  7. β-Ga2O3 on insulator field-effect transistors with drain currents exceeding 1.5 A/mm and their self-heating effect

    Science.gov (United States)

    Zhou, Hong; Maize, Kerry; Qiu, Gang; Shakouri, Ali; Ye, Peide D.

    2017-08-01

    We have demonstrated that depletion/enhancement-mode β-Ga2O3 on insulator field-effect transistors can achieve a record high drain current density of 1.5/1.0 A/mm by utilizing a highly doped β-Ga2O3 nano-membrane as the channel. β-Ga2O3 on insulator field-effect transistor (GOOI FET) shows a high on/off ratio of 1010 and low subthreshold slope of 150 mV/dec even with 300 nm thick SiO2. The enhancement-mode GOOI FET is achieved through surface depletion. An ultra-fast, high resolution thermo-reflectance imaging technique is applied to study the self-heating effect by directly measuring the local surface temperature. High drain current, low Rc, and wide bandgap make the β-Ga2O3 on insulator field-effect transistor a promising candidate for future power electronics applications.

  8. Shearon Harris steam generator channel head drain line leakage

    International Nuclear Information System (INIS)

    Bauer, P.A.

    1992-01-01

    All three Shearon Harris steam generators were equipped with Inconel 600 drain penetrations inserted into clearance holes on the bottom center line of the plenums, roll expanded into the plenum shell, and seal welded to the stainless steel cladding. Eddy current inspections showed axial cracks in the drain lines of B and C generators, but not on the leaking A generator. The drain lines of the three generators were repaired by cutting off the pipe under the plenum, applying Inconel 600 cladding to the underside of the plenum by a temper bead process, spot facing the overlay cladding and welding a new Inconel 600 pipe coupling to the clad surface. 3 figs

  9. Charge plasma based source/drain engineered Schottky Barrier MOSFET: Ambipolar suppression and improvement of the RF performance

    Science.gov (United States)

    Kale, Sumit; Kondekar, Pravin N.

    2018-01-01

    This paper reports a novel device structure for charge plasma based Schottky Barrier (SB) MOSFET on ultrathin SOI to suppress the ambipolar leakage current and improvement of the radio frequency (RF) performance. In the proposed device, we employ dual material for the source and drain formation. Therefore, source/drain is divided into two parts as main source/drain and source/drain extension. Erbium silicide (ErSi1.7) is used as main source/drain material and Hafnium metal is used as source/drain extension material. The source extension induces the electron plasma in the ultrathin SOI body resulting reduction of SB width at the source side. Similarly, drain extension also induces the electron plasma at the drain side. This significantly increases the SB width due to increased depletion at the drain end. As a result, the ambipolar leakage current can be suppressed. In addition, drain extension also reduces the parasitic capacitances of the proposed device to improve the RF performance. The optimization of length and work function of metal used in the drain extension is performed to achieve improvement in device performance. Moreover, the proposed device makes fabrication simpler, requires low thermal budget and free from random dopant fluctuations.

  10. Drain Back, Low Flow Solar Combi Systems

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2014-01-01

    Drain Back systems with ETC collectors are tested and analyzed in a Danish - Chinese cooperation project. Experiences from early work at DTU, with drain back, low flow systems, was used to design two systems: 1) One laboratory system at DTU and 2) One demonstration system in a single family house...... in Sorö Denmark. Detailed monitoring and modelling of the system in the DTU lab is done to be able to generalize the results, to other climates and loads and to make design optimizations. The advantage with drain back, low flow systems, is that the system can be made more simple with less components...... and that the performance can be enhanced. A combination of the drain back- and system expansion vessel was tested successfully. Small initial problems with installation and proposals for design improvements to avoid these in practice are described in the paper. Installer education and training is an important step to have...

  11. Controlling the ambipolarity and improvement of RF performance using Gaussian Drain Doped TFET

    Science.gov (United States)

    Nigam, Kaushal; Gupta, Sarthak; Pandey, Sunil; Kondekar, P. N.; Sharma, Dheeraj

    2018-05-01

    Ambipolar conduction in tunnel field-effect transistors (TFETs) has been occurred as an inherent issue due to drain-channel tunneling. It makes TFET less efficient and restricts its application in complementary digital circuits. Therefore, this manuscript reports the application of Gaussian doping profile on nanometer regime silicon channel TFETs to completely eliminate the ambipolarity. For this, Gaussian doping is used in the drain region of conventional gate-drain overlap TFET to control the tunneling of electrons from the valence band of channel to the conduction band of drain. As a result, barrier width at the drain/channel junction increases significantly leading to the suppression of an ambipolar current even when higher doping concentration (1 ? 10 ? cm ?) is considered in the drain region. However, significant improvement in terms of RF figure-of-merits such as cut-off frequency (f ?), gain bandwidth product (GBW), and gate-to-drain capacitance (C ?) is achieved with Gaussian doped gate on drain overlap TFET as compared to its counterpart TFET.

  12. Restructuring brain drain: strengthening governance and financing for health worker migration.

    Science.gov (United States)

    Mackey, Tim K; Liang, Bryan A

    2013-01-15

    Health worker migration from resource-poor countries to developed countries, also known as ''brain drain'', represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed.

  13. Analytical drift-current threshold voltage model of long-channel double-gate MOSFETs

    International Nuclear Information System (INIS)

    Shih, Chun-Hsing; Wang, Jhong-Sheng

    2009-01-01

    This paper presents a new, physical threshold voltage model to solve the ambiguity in determining the threshold voltage of double-gate (DG) MOSFETs. To avoid the difficulties of the conventional 2ψ B model in nearly undoped DG MOSFETs, this study proposes to define the on–off switching based on the actual roles of the drift and diffusion components in the total drain current. The drift current strongly enhances beyond the threshold voltage, while the diffusion current plays a major role in the subthreshold. The threshold voltage is defined as the drift component that exceeds the diffusion counterpart. From the solutions of Poisson's equation, the drift and diffusion currents of DG MOSFETs are separately formulated to derive the analytical expressions of the threshold voltage and associated threshold current. This model provides a comprehensive description of the switching behavior of DG MOSFET devices, and offers a physical onset threshold current to determine the threshold voltage in practical extraction

  14. Climate mitigation scenarios of drained peat soils

    Science.gov (United States)

    Kasimir Klemedtsson, Åsa; Coria, Jessica; He, Hongxing; Liu, Xiangping; Nordén, Anna

    2014-05-01

    The national inventory reports (NIR) submitted to the UNFCCC show Sweden - which as many other countries has wetlands where parts have been drained for agriculture and forestry purposes, - to annually emit 12 million tonnes carbon dioxide equivalents, which is more GHG'es than industrial energy use release in Sweden. Similar conditions can be found in other northern countries, having cool and wet conditions, naturally promoting peat accumulation, and where land use management over the last centuries have promoted draining activities. These drained peatland, though covering only 2% of the land area, have emissions corresponding to 20% of the total reported NIR emissions. This substantial emission contribution, however, is hidden within the Land Use Land Use Change and Forestry sector (LULUCF) where the forest Carbon uptake is even larger, which causes the peat soil emissions become invisible. The only drained soil emission accounted in the Swedish Kyoto reporting is the N2O emission from agricultural drained organic soils of the size 0.5 million tonnes CO2e yr-1. This lack of visibility has made incentives for land use change and management neither implemented nor suggested, however with large potential. Rewetting has the potential to decrease soil mineralization, why CO2 and N2O emissions are mitigated. However if the soil becomes very wet CH4 emission will increase together with hampered plant growth. By ecological modeling, using the CoupModel the climate change mitigation potential have been estimated for four different land use scenarios; 1, Drained peat soil with Spruce (business as usual scenario), 2, raised ground water level to 20 cm depth and Willow plantation, 3, raised ground water level to 10 cm depth and Reed Canary Grass, and 4, rewetting to an average water level in the soil surface with recolonizing wetland plants and mosses. We calculate the volume of biomass production per year, peat decomposition, N2O emission together with nitrate and DOC

  15. Toward refined environmental scenarios for ecological risk assessment of down-the-drain chemicals in freshwater environments.

    Science.gov (United States)

    Franco, Antonio; Price, Oliver R; Marshall, Stuart; Jolliet, Olivier; Van den Brink, Paul J; Rico, Andreu; Focks, Andreas; De Laender, Frederik; Ashauer, Roman

    2017-03-01

    Current regulatory practice for chemical risk assessment suffers from the lack of realism in conventional frameworks. Despite significant advances in exposure and ecological effect modeling, the implementation of novel approaches as high-tier options for prospective regulatory risk assessment remains limited, particularly among general chemicals such as down-the-drain ingredients. While reviewing the current state of the art in environmental exposure and ecological effect modeling, we propose a scenario-based framework that enables a better integration of exposure and effect assessments in a tiered approach. Global- to catchment-scale spatially explicit exposure models can be used to identify areas of higher exposure and to generate ecologically relevant exposure information for input into effect models. Numerous examples of mechanistic ecological effect models demonstrate that it is technically feasible to extrapolate from individual-level effects to effects at higher levels of biological organization and from laboratory to environmental conditions. However, the data required to parameterize effect models that can embrace the complexity of ecosystems are large and require a targeted approach. Experimental efforts should, therefore, focus on vulnerable species and/or traits and ecological conditions of relevance. We outline key research needs to address the challenges that currently hinder the practical application of advanced model-based approaches to risk assessment of down-the-drain chemicals. Integr Environ Assess Manag 2017;13:233-248. © 2016 SETAC. © 2016 SETAC.

  16. Modeling the long-term effect of winter cover crops on nitrate transport in artificially drained fields across the Midwest U.S.

    Science.gov (United States)

    A fall-planted cover crop is a management practice with multiple benefits including reducing nitrate losses from artificially drained fields. We used the Root Zone Water Quality Model (RZWQM) to simulate the impact of a cereal rye cover crop on reducing nitrate losses from drained fields across five...

  17. DRAINMOD-FOREST: Integrated Modeling of Hydrology, Soil Carbon and Nitrogen Dynamics, and Plant Growth for Drained Forests.

    Science.gov (United States)

    Tian, Shiying; Youssef, Mohamed A; Skaggs, R Wayne; Amatya, Devendra M; Chescheir, G M

    2012-01-01

    We present a hybrid and stand-level forest ecosystem model, DRAINMOD-FOREST, for simulating the hydrology, carbon (C) and nitrogen (N) dynamics, and tree growth for drained forest lands under common silvicultural practices. The model was developed by linking DRAINMOD, the hydrological model, and DRAINMOD-N II, the soil C and N dynamics model, to a forest growth model, which was adapted mainly from the 3-PG model. The forest growth model estimates net primary production, C allocation, and litterfall using physiology-based methods regulated by air temperature, water deficit, stand age, and soil N conditions. The performance of the newly developed DRAINMOD-FOREST model was evaluated using a long-term (21-yr) data set collected from an artificially drained loblolly pine ( L.) plantation in eastern North Carolina, USA. Results indicated that the DRAINMOD-FOREST accurately predicted annual, monthly, and daily drainage, as indicated by Nash-Sutcliffe coefficients of 0.93, 0.87, and 0.75, respectively. The model also predicted annual net primary productivity and dynamics of leaf area index reasonably well. Predicted temporal changes in the organic matter pool on the forest floor and in forest soil were reasonable compared to published literature. Both predicted annual and monthly nitrate export were in good agreement with field measurements, as indicated by Nash-Sutcliffe coefficients above 0.89 and 0.79 for annual and monthly predictions, respectively. This application of DRAINMOD-FOREST demonstrated its capability for predicting hydrology and C and N dynamics in drained forests under limited silvicultural practices. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  18. Enhanced performance of amorphous In-Ga-Zn-O thin-film transistors using different metals for source/drain electrodes

    Science.gov (United States)

    Pyo, Ju-Young; Cho, Won-Ju

    2017-09-01

    In this paper, we propose an amorphous indium gallium zinc oxide (a-IGZO) thin-film transistor (TFT) with off-planed source/drain electrodes. We applied different metals for the source/drain electrodes with Ni and Ti to control the work function as high and low. When we measured the configuration of Ni to drain and source to Ti, the a-IGZO TFT showed increased driving current, decreased leakage current, a high on/off current ratio, low subthreshold swing, and high mobility. In addition, we conducted a reliability test with a gate bias stress test at various temperatures. The results of the reliability test showed the Ni drain and Ti drain had an equivalent effective energy barrier height. Thus, we confirmed that the proposed off-planed structure improved the electrical characteristics of the fabricated devices without any degradation of characteristics. Through the a-IGZO TFT with different source/drain electrode metal engineering, we realized high-performance TFTs for next-generation display devices.

  19. Using Smoke Injection in Drains to Identify Potential Preferential Pathways in a Drained Arable Field

    Science.gov (United States)

    Nielsen, M. H.; Petersen, C. T.; Hansen, S.

    2014-12-01

    Macropores forming a continuous pathway between the soil surface and subsurface drains favour the transport of many contaminants from agricultural fields to surface waters. The smoke injection method presented by Shipitalo and Gibbs (2000) used for demonstrating and quantifying such pathways has been further developed and used on a drained Danish sandy loam. In order to identify the preferential pathways to drains, smoke was injected in three 1.15 m deep tile drains (total drain length 93 m), and smoke emitting macropores (SEMP) at the soil surface were counted and characterized as producing either strong or weak plumes compared to reference plumes from 3 and 6 mm wide tubes. In the two situations investigated in the present study - an early spring and an autumn situation, smoke only penetrated the soil surface layer via earthworm burrows located in a 1.0 m wide belt directly above the drain lines. However, it is known from previous studies that desiccation fractures in a dry summer situation also can contribute to the smoke pattern. The distance between SEMP measured along the drain lines was on average 0.46 m whereas the average spacing between SEMP with strong plumes was 2.3 m. Ponded water was applied in 6 cm wide rings placed above 52 burrows including 17 reference burrows which did not emit smoke. Thirteen pathways in the soil were examined using dye tracer and profile excavation. SEMP with strong plumes marked the entrance of highly efficient transport pathways conducting surface applied water and dye tracer into the drain. However, no single burrow was traced all the way from the surface into the drain, the dye patterns branched off in a network of other macropores. Water infiltration rates were significantly higher (P drains and surface waters, pathways being associated primarily with unevenly distributed SEMP producing strong smoke plumes.

  20. Pesticide transport to tile-drained fields in SWAT model – macropore flow and sediment

    DEFF Research Database (Denmark)

    Lu, Shenglan; Trolle, Dennis; Blicher-Mathiesen, Gitte

    2015-01-01

    Tool (SWAT) to simulate transport of both mobile (e.g. Bentazon) and strongly sorbed (e.g. Diuron) pesticides in tile drains. Macropore flow is initiated when soil water content exceeds a threshold and rainfall intensity exceeds infiltration capacity. The amount of macropore flow is calculated...... to macropore sediment transport. Simulated tile drain discharge, sediment and pesticide loads are calibrated against data from intensively monitored tile-drained fields and streams in Denmark....

  1. An analytical threshold voltage model for a short-channel dual-metal-gate (DMG) recessed-source/drain (Re-S/D) SOI MOSFET

    Science.gov (United States)

    Saramekala, G. K.; Santra, Abirmoya; Dubey, Sarvesh; Jit, Satyabrata; Tiwari, Pramod Kumar

    2013-08-01

    In this paper, an analytical short-channel threshold voltage model is presented for a dual-metal-gate (DMG) fully depleted recessed source/drain (Re-S/D) SOI MOSFET. For the first time, the advantages of recessed source/drain (Re-S/D) and of dual-metal-gate structure are incorporated simultaneously in a fully depleted SOI MOSFET. The analytical surface potential model at Si-channel/SiO2 interface and Si-channel/buried-oxide (BOX) interface have been developed by solving the 2-D Poisson’s equation in the channel region with appropriate boundary conditions assuming parabolic potential profile in the transverse direction of the channel. Thereupon, a threshold voltage model is derived from the minimum surface potential in the channel. The developed model is analyzed extensively for a variety of device parameters like the oxide and silicon channel thicknesses, thickness of source/drain extension in the BOX, control and screen gate length ratio. The validity of the present 2D analytical model is verified with ATLAS™, a 2D device simulator from SILVACO Inc.

  2. Treatment of bilge and oily drain water of tankers and current measures against combustible oil gas discharge; Tanker no biruji yudakusui shori oyobi kanensei sekiyu gas haishutsu taiskau no genjo

    Energy Technology Data Exchange (ETDEWEB)

    Agatsuma, Y.

    1996-07-25

    This paper describes the current actual conditions on treatment of bilge discharged from engine area and oily drain water from cargo area of tankers. Clean bilge among various bilges discharged from engine area such as vapor drain, fresh water, rainwater, seawater and condensed water is directly dumped into the sea after temporary storage in a clean tank. Oily bilge is produced mainly by mixing of clean bilge and leakage oil from main engines and various auxiliaries. Oily bilge is dumped into the sea under comparative monitoring of the bilge quality with the dumping standard by oil concentration monitoring and control equipment after the primary treatment in a treatment tank and the secondary treatment in a bilge separator. Oily drain water from cargo area contains water ballast for cargo oil tanks, wash water for tanks and lines, and bilge produced in pump room. The oily drain water is dumped under a specific condition. However, water ballast for specific ballast tanks is excluded from the oily drain water. 2 figs.

  3. Modified APEX model for Simulating Macropore Phosphorus Contributions to Tile Drains.

    Science.gov (United States)

    Ford, William I; King, Kevin W; Williams, Mark R; Confesor, Remegio B

    2017-11-01

    The contribution of macropore flow to phosphorus (P) loadings in tile-drained agricultural landscapes remains poorly understood at the field scale, despite the recognized deleterious impacts of contaminant transport via macropore pathways. A new subroutine that couples existing matrix-excess and matrix-desiccation macropore flow theory and a modified P routine is implemented in the Agricultural Policy Environmental eXtender (APEX) model. The original and modified formulation were applied and evaluated for a case study in a poorly drained field in Western Ohio with 31 months of surface and subsurface monitoring data. Results highlighted that a macropore subroutine in APEX improved edge-of-field discharge calibration and validation for both tile and total discharge from satisfactory and good, respectively, to very good and improved dissolved reactive P load calibration and validation statistics for tile P loads from unsatisfactory to very good. Output from the calibrated macropore simulations suggested median annual matrix-desiccation macropore flow contributions of 48% and P load contributions of 43%, with the majority of loading occurring in winter and spring. While somewhat counterintuitive, the prominence of matrix-desiccation macropore flow during seasons with less cracking reflects the importance of coupled development of macropore pathways and adequate supply of the macropore flow source. The innovative features of the model allow for assessments of annual macropore P contributions to tile drainage and has the potential to inform P site assessment tools. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  4. The fabrication of carbon nanotube field-effect transistors with semiconductors as the source and drain contact materials.

    Science.gov (United States)

    Xiao, Z; Camino, F E

    2009-04-01

    Sb(2)Te(3) and Bi(2)Te(2)Se semiconductor materials were used as the source and drain contact materials in the fabrication of carbon nanotube field-effect transistors (CNTFETs). Ultra-purified single-walled carbon nanotubes (SWCNTs) were ultrasonically dispersed in N-methyl pyrrolidone solvent. Dielectrophoresis was used to deposit and align SWCNTs for fabrication of CNTFETs. The Sb(2)Te(3)- and Bi(2)Te(2)Se-based CNTFETs demonstrate p-type metal-oxide-silicon-like I-V curves with high on/off drain-source current ratio at large drain-source voltages and good saturation of drain-source current with increasing drain-source voltage. The fabrication process developed is novel and has general meaning, and could be used for the fabrication of SWCNT-based integrated devices and systems with semiconductor contact materials.

  5. Impact of a drain field plate on the breakdown characteristics of AlInN/GaN MOSHEMT

    Science.gov (United States)

    Jena, Kanjalochan; Swain, Raghunandan; Lenka, T. R.

    2015-11-01

    In this paper, a novel AlInN/GaN metal oxide semiconductor high electron mobility transistor (MOSHEMT) employing the drain field plate technique is proposed and the effect of a drain field plate on the breakdown voltage (BV) is investigated. A reduction of the peak electric field is required to achieve AlInN/GaN MOSHEMTs with a high BV. The proposed AlInN/GaN MOSHEMT with both gate and drain field plates simultaneously reduces the electric field concentration at the gate and the drain edge by decreasing the potential gradient along the channel for the 2 dimensional electron gas (2DEG). The reduction in the peak electric field at the drain edge of the proposed device leads to a 57% increase in BV compared with the BV for an AlInN/GaN MOSHEMT with a gate field plate only. A significantly higher BV can be achieved by optimizing the gate-to-drain distance (L gd ), the length of the drain field plate (L dfp ) and the thickness of the SiN passivation layer thickness (T SiN ). A detailed breakdown analysis of the device was carried out using Silvaco Technology Computer Aided Design (TCAD). The detailed numerical simulations were done by using the non-local energy balance (EB) transport model, which was calibrated with the previously published experimental results. The results showed a great potential for applications of the drain-field-plated AlInN/GaN MOSHEMT to deliver high currents and high powers in microwave technologies.

  6. Modelling Technique for the Assessment of the Sub-Soil Drain for Groundwater Seepage Remediation

    Directory of Open Access Journals (Sweden)

    Tajul Baharuddin Mohamad Faizal

    2017-01-01

    Full Text Available Groundwater simulation technique was carried out for examining the performance of sub-soil drain at problematic site area. Subsoil drain was proposed as one of solution for groundwater seepage occurred at the slope face by reducing groundwater table at Taman Botani Park Kuala Lumpur. The simulation technique used Modular Three-Dimensional Finite Difference Groundwater Flow (MODFLOW software. In transient conditions, the results of simulation showed that heads increases surpass 1 to 2 m from the elevation level of the slope area that caused groundwater seepage on slope face. This study attempt to decrease the heads increase surpass by using different sub-soil drain size in simulation technique. The sub-soil drain capable to decline the heads ranges of 1 to 2 m.

  7. Simulation of the hydraulic performance of highway filter drains through laboratory models and stormwater management tools.

    Science.gov (United States)

    Sañudo-Fontaneda, Luis A; Jato-Espino, Daniel; Lashford, Craig; Coupe, Stephen J

    2017-05-23

    Road drainage is one of the most relevant assets in transport infrastructure due to its inherent influence on traffic management and road safety. Highway filter drains (HFDs), also known as "French Drains", are the main drainage system currently in use in the UK, throughout 7000 km of its strategic road network. Despite being a widespread technique across the whole country, little research has been completed on their design considerations and their subsequent impact on their hydraulic performance, representing a gap in the field. Laboratory experiments have been proven to be a reliable indicator for the simulation of the hydraulic performance of stormwater best management practices (BMPs). In addition to this, stormwater management tools (SMT) have been preferentially chosen as a design tool for BMPs by practitioners from all over the world. In this context, this research aims to investigate the hydraulic performance of HFDs by comparing the results from laboratory simulation and two widely used SMT such as the US EPA's stormwater management model (SWMM) and MicroDrainage®. Statistical analyses were applied to a series of rainfall scenarios simulated, showing a high level of accuracy between the results obtained in laboratory and using SMT as indicated by the high and low values of the Nash-Sutcliffe and R 2 coefficients and root-mean-square error (RMSE) reached, which validated the usefulness of SMT to determine the hydraulic performance of HFDs.

  8. A prospective randomized study of use of drain versus no drain after burr-hole evacuation of chronic subdural hematoma.

    Science.gov (United States)

    Singh, Amit Kumar; Suryanarayanan, Bhaskar; Choudhary, Ajay; Prasad, Akhila; Singh, Sachin; Gupta, Laxmi Narayan

    2014-01-01

    Chronic subdural hematoma (CSDH) recurs after surgical evacuation in 5-30% of patients. Inserting subdural drain might reduce the recurrence rate, but is not commonly practiced. There are few prospective studies to evaluate the effect of subdural drains. A prospective randomized study to investigate the effect of subdural drains in the on recurrence rates and clinical outcome following burr-hole drainage (BHD) of CSDH was undertaken. During the study period, 246 patients with CSDH were assessed for eligibility. Among 200 patients fulfilling the eligibility criteria, 100 each were assigned to "drain group" (drain inserted into the subdural space following BHD) and "without drain group" (subdural drain was not inserted following BHD) using random allocation software. The primary end point was recurrence needing re-drainage up to a period of 6 months from surgery. Recurrence occurred in 9 of 100 patients with a drain, and 26 of 100 patients in without drain group (P = 0.002). The mortality was 5% in patients with drain and 4% in patients without drain group (P = 0.744). The medical and surgical complications were comparable between the two study groups. Use of a subdural drain after burr-hole evacuation of a CSDH reduces the recurrence rate and is not associated with increased complications.

  9. Accounting for the risks of phosphorus losses through tile drains in a phosphorus index.

    Science.gov (United States)

    Reid, D Keith; Ball, Bonnie; Zhang, T Q

    2012-01-01

    Tile drainage systems have been identified as a significant conduit for phosphorus (P) losses to surface water, but P indices do not currently account for this transport pathway in a meaningful way. Several P indices mention tile drains, but most account for either the reduction in surface runoff or the enhanced transport through tiles rather than both simultaneously. A summary of the current state of how tile drains are accounted for within P indices is provided, and the challenges in predicting the risk of P losses through tile drains that are relative to actual losses are discussed. A framework for a component P Index is described, along with a proposal to incorporate predictions of losses through tile drains as a component within this framework. Options for calibrating and testing this component are discussed. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  10. Novel technique of source and drain engineering for dual-material double-gate (DMDG) SOI MOSFETS

    Science.gov (United States)

    Yadav, Himanshu; Malviya, Abhishek Kumar; Chauhan, R. K.

    2018-04-01

    The dual-metal dual-gate (DMDG) SOI has been used with Dual Sided Source and Drain Engineered 50nm SOI MOSFET with various high-k gate oxide. It has been scrutinized in this work to enhance its electrical performance. The proposed structure is designed by creating Dual Sided Source and Drain Modification and its characteristics are evaluated on ATLAS device simulator. The consequence of this dual sided assorted doping on source and drain side of the DMDG transistor has better leakage current immunity and heightened ION current with higher ION to IOFF Ratio. Which thereby vesting the proposed device appropriate for low power digital applications.

  11. Effect of asymmetrical double-pockets and gate-drain underlap on Schottky barrier tunneling FET: Ambipolar conduction vs. high frequency performance

    Science.gov (United States)

    Shaker, Ahmed; Ossaimee, Mahmoud; Zekry, A.

    2016-08-01

    In this paper, a proposed structure based on asymmetrical double pockets SB-TFET with gate-drain underlap is presented. 2D extensive modeling and simulation, using Silvaco TCAD, were carried out to study the effect of both underlap length and pockets' doping on the transistor performance. It was found that the underlap from the drain side suppresses the ambipolar conduction and doesn't enhance the high-frequency characteristics. The enhancement of the high-frequency characteristics could be realized by increasing the doping of the drain pocket over the doping of the source pocket. An optimum choice was found which gives the conditions of minimum ambipolar conduction, maximum ON current and maximum cut-off frequency. These enhancements render the device more competitive as a nanometer transistor.

  12. Modeling the impact of nitrogen fertilizer application and tile drain configuration on nitrate leaching using SWAT

    Science.gov (United States)

    Recently, the Soil and Water Assessment Tool (SWAT) was revised to improve the partitioning of runoff and tile drainage in poorly drained soils by modifying the algorithm for computing the soil moisture retention parameter. In this study, the revised SWAT model was used to evaluate the sensitivity a...

  13. The stable stiffness triangle - drained sand during deformation cycles

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    2017-01-01

    Cyclic, drained sand stiffness was observed using the Danish triaxial appa- ratus. New, deformation dependant soil property (the stable stiffness triangle) was detected. Using the the stable stiffness triangle, secant stiffness of drained sand was plausible to predict (and control) even during ir...... findings can find application in off-shore, seismic and other engi- neering practice, or inspire new branches of research and modelling wherever dynamic, cyclic or transient loaded sand is encountered....

  14. Barrier reduction via implementation of InGaN interlayer in wafer-bonded current aperture vertical electron transistors consisting of InGaAs channel and N-polar GaN drain

    International Nuclear Information System (INIS)

    Kim, Jeonghee; Laurent, Matthew A.; Li, Haoran; Lal, Shalini; Mishra, Umesh K.

    2015-01-01

    This letter reports the influence of the added InGaN interlayer on reducing the inherent interfacial barrier and hence improving the electrical characteristics of wafer-bonded current aperture vertical electron transistors consisting of an InGaAs channel and N-polar GaN drain. The current-voltage characteristics of the transistors show that the implementation of N-polar InGaN interlayer effectively reduces the barrier to electron transport across the wafer-bonded interface most likely due to its polarization induced downward band bending, which increases the electron tunneling probability. Fully functional wafer-bonded transistors with nearly 600 mA/mm of drain current at V GS  = 0 V and L go  = 2 μm have been achieved, and thus demonstrate the feasibility of using wafer-bonded heterostructures for applications that require active carrier transport through both materials

  15. High performance AlGaN/GaN HEMTs with 2.4 μm source-drain spacing

    International Nuclear Information System (INIS)

    Wang Dongfang; Wei Ke; Yuan Tingting; Liu Xinyu

    2010-01-01

    This paper describes the performance of AlGaN/GaN HEMTs with 2.4 μm source-drain spacing. So far these are the smallest source-drain spacing AlGaN/GaN HEMTs which have been implemented with a domestic wafer and domestic process. This paper also compares their performance with that of 4 μm source-drain spacing devices. The former exhibit higher drain current, higher gain, and higher efficiency. It is especially significant that the maximum frequency of oscillation noticeably increased. (semiconductor integrated circuits)

  16. Homogenization of one-dimensional draining through heterogeneous porous media including higher-order approximations

    Science.gov (United States)

    Anderson, Daniel M.; McLaughlin, Richard M.; Miller, Cass T.

    2018-02-01

    We examine a mathematical model of one-dimensional draining of a fluid through a periodically-layered porous medium. A porous medium, initially saturated with a fluid of a high density is assumed to drain out the bottom of the porous medium with a second lighter fluid replacing the draining fluid. We assume that the draining layer is sufficiently dense that the dynamics of the lighter fluid can be neglected with respect to the dynamics of the heavier draining fluid and that the height of the draining fluid, represented as a free boundary in the model, evolves in time. In this context, we neglect interfacial tension effects at the boundary between the two fluids. We show that this problem admits an exact solution. Our primary objective is to develop a homogenization theory in which we find not only leading-order, or effective, trends but also capture higher-order corrections to these effective draining rates. The approximate solution obtained by this homogenization theory is compared to the exact solution for two cases: (1) the permeability of the porous medium varies smoothly but rapidly and (2) the permeability varies as a piecewise constant function representing discrete layers of alternating high/low permeability. In both cases we are able to show that the corrections in the homogenization theory accurately predict the position of the free boundary moving through the porous medium.

  17. Modeling flow and solute transport at a tile drain field site by explicit representation of preferential flow structures: Equifinality and uncertainty

    Science.gov (United States)

    Zehe, E.; Klaus, J.

    2011-12-01

    Rapid flow in connected preferential flow paths is crucial for fast transport of water and solutes through soils, especially at tile drained field sites. The present study tests whether an explicit treatment of worm burrows is feasible for modeling water flow, bromide and pesticide transport in structured heterogeneous soils with a 2-dimensional Richards based model. The essence is to represent worm burrows as morphologically connected paths of low flow resistance and low retention capacity in the spatially highly resolved model domain. The underlying extensive database to test this approach was collected during an irrigation experiment, which investigated transport of bromide and the herbicide Isoproturon at a 900 sqm tile drained field site. In a first step we investigated whether the inherent uncertainty in key data causes equifinality i.e. whether there are several spatial model setups that reproduce tile drain event discharge in an acceptable manner. We found a considerable equifinality in the spatial setup of the model, when key parameters such as the area density of worm burrows and the maximum volumetric water flows inside these macropores were varied within the ranges of either our measurement errors or measurements reported in the literature. Thirteen model runs yielded a Nash-Sutcliffe coefficient of more than 0.9. Also, the flow volumes were in good accordance and peak timing errors where less than or equal to 20 min. In the second step we investigated thus whether this "equifinality" in spatial model setups may be reduced when including the bromide tracer data into the model falsification process. We simulated transport of bromide for the 13 spatial model setups, which performed best with respect to reproduce tile drain event discharge, without any further calibration. Four of this 13 model setups allowed to model bromide transport within fixed limits of acceptability. Parameter uncertainty and equifinality could thus be reduced. Thirdly, we selected

  18. Comparative investigation of novel hetero gate dielectric and drain engineered charge plasma TFET for improved DC and RF performance

    Science.gov (United States)

    Yadav, Dharmendra Singh; Verma, Abhishek; Sharma, Dheeraj; Tirkey, Sukeshni; Raad, Bhagwan Ram

    2017-11-01

    Tunnel-field-effect-transistor (TFET) has emerged as one of the most prominent devices to replace conventional MOSFET due to its ability to provide sub-threshold slope below 60 mV/decade (SS ≤ 60 mV/decade) and low leakage current. Despite this, TFETs suffer from ambipolar behavior, lower ON-state current, and poor RF performance. To address these issues, we have introduced drain and gate work function engineering with hetero gate dielectric for the first time in charge plasma based doping-less TFET (DL TFET). In this, the usage of dual work functionality over the drain region significantly reduces the ambipolar behavior of the device by varying the energy barrier at drain/channel interface. Whereas, the presence of dual work function at the gate terminal increases the ON-state current (ION). The combined effect of dual work function at the gate and drain electrode results in the increment of ON-state current (ION) and decrement of ambipolar conduction (Iambi) respectively. Furthermore, the incorporation of hetero gate dielectric along with dual work functionality at the drain and gate electrode provides an overall improvement in the performance of the device in terms of reduction in ambipolarity, threshold voltage and sub-threshold slope along with improved ON-state current and high frequency figures of merit.

  19. Continuous 'Passive' Registration of Non-Point Contaminant Loads Via Agricultural Subsurface Drain Tubes

    Science.gov (United States)

    Rozemeijer, J.; Jansen, S.; de Jonge, H.; Lindblad Vendelboe, A.

    2014-12-01

    Considering their crucial role in water and solute transport, enhanced monitoring and modeling of agricultural subsurface tube drain systems is important for adequate water quality management. For example, previous work in lowland agricultural catchments has shown that subsurface tube drain effluent contributed up to 80% of the annual discharge and 90-92% of the annual NO3 loads from agricultural fields towards the surface water. However, existing monitoring techniques for flow and contaminant loads from tube drains are expensive and labor-intensive. Therefore, despite the unambiguous relevance of this transport route, tube drain monitoring data are scarce. The presented study aimed developing a cheap, simple, and robust method to monitor loads from tube drains. We are now ready to introduce the Flowcap that can be attached to the outlet of tube drains and is capable of registering total flow, contaminant loads, and flow-averaged concentrations. The Flowcap builds on the existing SorbiCells, a modern passive sampling technique that measures average concentrations over longer periods of time (days to months) for various substances. By mounting SorbiCells in our Flowcap, a flow-proportional part of the drain effluent is sampled from the main stream. Laboratory testing yielded good linear relations (R-squared of 0.98) between drainage flow rates and sampling rates. The Flowcap was tested in practice for measuring NO3 loads from two agricultural fields and one glasshouse in the Netherlands. The Flowcap registers contaminant loads from tube drains without any need for housing, electricity, or maintenance. This enables large-scale monitoring of non-point contaminant loads via tube drains, which would facilitate the improvement of contaminant transport models and would yield valuable information for the selection and evaluation of mitigation options to improve water quality.

  20. A Rare Complication of Abdominal Drain: Fallopian Tube Herniation Through the Drain Site

    OpenAIRE

    Dilek Uygur; Seval Erdinç; Hülya Dede; Ümit Taşdemir; Oktay Kaymak; Nuri Danışman

    2016-01-01

    Prophylactic drainage of the peritoneal cavity after obstetrical and gynecological surgery is widely practiced. The idea of “when in doubt, drain” is accepted and applied clinically by many surgeons. However, surgically placed drains are not without risk. The present case describes herniation of fallopian tube during the removal of a surgical drain placed after a cesarean section.

  1. Restructuring brain drain: strengthening governance and financing for health worker migration

    Directory of Open Access Journals (Sweden)

    Tim K. Mackey

    2013-01-01

    Full Text Available Background: Health worker migration from resource-poor countries to developed countries, also known as ‘‘brain drain’’, represents a serious global health crisis and a significant barrier to achieving global health equity. Resource-poor countries are unable to recruit and retain health workers for domestic health systems, resulting in inadequate health infrastructure and millions of dollars in healthcare investment losses. Methods: Using acceptable methods of policy analysis, we first assess current strategies aimed at alleviating brain drain and then propose our own global health policy based solution to address current policy limitations. Results: Although governments and private organizations have tried to address this policy challenge, brain drain continues to destabilise public health systems and their populations globally. Most importantly, lack of adequate financing and binding governance solutions continue to fail to prevent health worker brain drain. Conclusions: In response to these challenges, the establishment of a Global Health Resource Fund in conjunction with an international framework for health worker migration could create global governance for stable funding mechanisms encourage equitable migration pathways, and provide data collection that is desperately needed.

  2. Analytical solutions for a single vertical drain with time-dependent vacuum combined surcharge preloading in membrane and membraneless systems

    International Nuclear Information System (INIS)

    Geng, X Y; Indraratna, B; Rujikiatkamjorn, C

    2010-01-01

    Vertical drains combined with vacuum pressure and surcharge preloading are widely used to accelerate the consolidation process of soft clay in order to decrease the pore pressure as well as to increase the effective stress. Currently there are two types of vacuum preloading systems commercially available; (a) membrane system with an airtight membrane over the drainage layer and, (b) membraneless system where a vacuum system is connected to individual drain. Their effectiveness varies from site to site depending on the type of soil treated and the characteristics of the drain-vacuum system. This study presents the analytical solutions of vertical drains with vacuum preloading for both membrane and membraneless systems. According to the field and laboratory observations, the vacuum in both of the membraneless and membrane system was assumed to be decreasing along the drain whereas in the membrane system, it was maintained at a constant level. This model was verified by using the measured settlements and excess pore pressures obtained from large-scale laboratory testing and case studies in Australia. The analytical solutions improved the accuracy of predicting the dissipation of pore water pressure and the associated settlement. The effects of the permeability of the sand blanket in a membrane system and the possible loss of vacuum were also discussed.

  3. Drain Current Stress-Induced Instability in Amorphous InGaZnO Thin-Film Transistors with Different Active Layer Thicknesses

    Directory of Open Access Journals (Sweden)

    Dapeng Wang

    2018-04-01

    Full Text Available In this study, the initial electrical properties, positive gate bias stress (PBS, and drain current stress (DCS-induced instabilities of amorphous indium gallium zinc oxide (a-IGZO thin-film transistors (TFTs with various active layer thicknesses (TIGZO are investigated. As the TIGZO increased, the turn-on voltage (Von decreased, while the subthreshold swing slightly increased. Furthermore, the mobility of over 13 cm2·V−1·s−1 and the negligible hysteresis of ~0.5 V are obtained in all of the a-IGZO TFTs, regardless of the TIGZO. The PBS results exhibit that the Von shift is aggravated as the TIGZO decreases. In addition, the DCS-induced instability in the a-IGZO TFTs with various TIGZO values is revealed using current–voltage and capacitance–voltage (C–V measurements. An anomalous hump phenomenon is only observed in the off state of the gate-to-source (Cgs curve for all of the a-IGZO TFTs. This is due to the impact ionization that occurs near the drain side of the channel and the generated holes that flow towards the source side along the back-channel interface under the lateral electric field, which cause a lowered potential barrier near the source side. As the TIGZO value increased, the hump in the off state of the Cgs curve was gradually weakened.

  4. A Rare Complication of Abdominal Drain: Fallopian Tube Herniation Through the Drain Site

    Directory of Open Access Journals (Sweden)

    Dilek Uygur

    2016-05-01

    Full Text Available Prophylactic drainage of the peritoneal cavity after obstetrical and gynecological surgery is widely practiced. The idea of “when in doubt, drain” is accepted and applied clinically by many surgeons. However, surgically placed drains are not without risk. The present case describes herniation of fallopian tube during the removal of a surgical drain placed after a cesarean section.

  5. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  6. 21 CFR 868.5995 - Tee drain (water trap).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tee drain (water trap). 868.5995 Section 868.5995...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5995 Tee drain (water trap). (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator...

  7. Development of rationalized system treating floor drain

    International Nuclear Information System (INIS)

    Nakamura, Yasuyuki; Serizawa, Kenichi; Komatsu, Akihiro; Shimizu, Takayuki

    1998-01-01

    Radioactive liquid wastes generated at BWR plants are collected and treated as required. These days, however, generation of floor drain has deceased and HFF (Hollow Fiber Filter) has experienced a wide applicability to several kinds of liquid wastes. We should consider that the floor drain can be mixed and diluted with equipment drain and be purified by HFF. That enables some of the sumps and long priming pipes to be combined. From this point of view, we have developed a highly rationalized waste liquid system. We have evaluated the applicability of this system after an investigation into the generation and properties of floor drain and equipment drain at the latest BWR'S and an on-site test at a typical BWR. (author)

  8. Carbon accumulation in pristine and drained mires

    Energy Technology Data Exchange (ETDEWEB)

    Maekilae, M.

    2011-07-01

    The carbon accumulation of 73 peat columns from 48 pristine and drained mires was investigated using a total of 367 dates and age-depth models derived from bulk density measurements. Peat columns were collected from mires of varying depth, age, degree of natural state and nutrient conditions in aapa mire and raised bog regions and coastal mires from southern and central Finland and Russian Karelia. Particular attention was paid to the accumulation of carbon over the last 300 years, as this period encompasses the best estimates of the oxic layer (acrotelm) age across the range of sites investigated. In general, drained mires are initially more nutrient-rich than pristine mires. Organic matter decomposes more rapidly at drained sites than at pristine sites, resulting in thinner peat layers and carbon accumulation but a higher dry bulk density and carbon content. The average carbon accumulation was calculated as 24.0 g m-2 yr-1 at pristine sites and 19.4 g m-2 yr-1 at drained sites, while for peat layers younger than 300 years the respective figures were 45.3 and 34.5 g m-2 yr-1 at pristine and drained sites. For the <300-year-old peat layers studied here, the average thickness was 19 cm less and the carbon accumulation rate 10.8 g m-2 yr-1 lower in drained areas than in pristine areas. The amount carbon accumulation of surface peat layers depends upon the mire site type, vegetation and natural state; variations reflect differences in plant communities as well as factors that affect biomass production and decay rates. The highest accumulation rates and thus carbon binding for layers younger than 300 years were measured in the ombrotrophic mire site types (Sphagnum fuscum bog and Sphagnum fuscum pine bog), and the second highest rates in wet, treeless oligotrophic and minerotrophic mire site types. The lowest values of carbon accumulation over the last 300 years were obtained for the most transformed, sparsely forested and forested mire site types, where the water

  9. How to remove a chest drain.

    Science.gov (United States)

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  10. Thermal drift reduction with multiple bias current for MOSFET dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Carvajal, M A; Martinez-Olmos, A; Morales, D P; Lopez-Villanueva, J A; Palma, A J [Departamento de Electronica y TecnologIa de Computadores, ETSIIT, Universidad de Granada, E-18071 Granada (Spain); Lallena, A M, E-mail: carvajal@ugr.es [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2011-06-21

    New thermal compensation methods suitable for p-channel MOSFET (pMOS) dosimeters with the usual dose readout procedure based on a constant drain current are presented. Measuring the source-drain voltage shifts for two or three different drain currents and knowing the value of the zero-temperature coefficient drain current, I{sub ZTC}, the thermal drift of source-drain or threshold voltages can be significantly reduced. Analytical expressions for the thermal compensation have been theoretically deduced on the basis of a linear dependence on temperature of the parameters involved. The proposed thermal modelling has been experimentally proven. These methods have been applied to a group of ten commercial pMOS transistors (3N163). The thermal coefficients of the source-drain voltage and the threshold voltage were reduced from -3.0 mV deg. C{sup -1}, in the worst case, down to -70 {mu}V deg. C{sup -1}. This means a thermal drift of -2.4 mGy deg. C{sup -1} for the dosimeter. When analysing the thermal drifts of all the studied transistors, in the temperature range from 19 to 36 deg. C, uncertainty was obtained in the threshold voltage due to a thermal drift of {+-}9mGy (2 SD), a commonly acceptable value in most radiotherapy treatments. The procedures described herein provide thermal drift reduction comparable to that of other technological or numerical strategies, but can be used in a very simple and low-cost dosimetry sensor.

  11. 216-Z-8 French drain characterization study

    International Nuclear Information System (INIS)

    Marratt, M.C.; Kasper, R.B.; Van Luik, A.E.

    1984-09-01

    The 216-Z-8 French drain study is one of a series of studies examining historical transuranic waste facilities no longer in use at the Hanford Site. The 216-Z-8 French drain underground disposal system consisted of a large settling tank that overflowed into a French drain. The French drain consisted of two large-diameter, gravel filled, vitrified clay pipes placed on end, end-to-end, over a gravel-filled excavation. The top of the drain was sealed with concrete to prevent the upward flow of waste solution. The waste solution discharged to the 216-Z-8 waste disposal system was a neutralized, transuranic recovery process, filter cake, backflush slurry. The primary objective of this study was to determine the distribution of plutonium and americium beneath the French drain. Transuranic activity under the French drain did not exceed 5 nCi/g in the soil samples obtained from a well within 1 m of the drain structure. Conservative estimates indicated that 4 to 5 m 3 of radioactive contaminated sediments, 10 nCi/g may lie directly under the 216-Z-8 French drain. The secondary objective of the study was to evaluate the possibility of a leak in the settling tank. Results from the analysis of soil samples from wells drilled around the settling tank indicated the presence of low-level transuranic contamination (on the order of 0.001 nci/g) in the soil surrounding the tank. However, the distribution of the contamination does not support a leak as a plausible mechanism to account for the observed activity surrounding the tank. The bulk of the plutonium was confirmed to be in the sludge that remained in the tank; thus, no significant environmental impact would be expected even if there has been a leak

  12. A novel gate and drain engineered charge plasma tunnel field-effect transistor for low sub-threshold swing and ambipolar nature

    Science.gov (United States)

    Yadav, Dharmendra Singh; Raad, Bhagwan Ram; Sharma, Dheeraj

    2016-12-01

    In this paper, we focus on the improvement of figures of merit for charge plasma based tunnel field-effect transistor (TFET) in terms of ON-state current, threshold voltage, sub-threshold swing, ambipolar nature, and gate to drain capacitance which provides better channel controlling of the device with improved high frequency response at ultra-low supply voltages. Regarding this, we simultaneously employ work function engineering on the drain and gate electrode of the charge plasma TFET. The use of gate work function engineering modulates the barrier on the source/channel interface leads to improvement in the ON-state current, threshold voltage, and sub-threshold swing. Apart from this, for the first time use of work function engineering on the drain electrode increases the tunneling barrier for the flow of holes on the drain/channel interface, it results into suppression of ambipolar behavior. The lowering of gate to drain capacitance therefore enhanced high frequency parameters. Whereas, the presence of dual work functionality at the gate electrode and over the drain region improves the overall performance of the charge plasma based TFET.

  13. Drain Current Stress-Induced Instability in Amorphous InGaZnO Thin-Film Transistors with Different Active Layer Thicknesses.

    Science.gov (United States)

    Wang, Dapeng; Zhao, Wenjing; Li, Hua; Furuta, Mamoru

    2018-04-05

    In this study, the initial electrical properties, positive gate bias stress (PBS), and drain current stress (DCS)-induced instabilities of amorphous indium gallium zinc oxide (a-IGZO) thin-film transistors (TFTs) with various active layer thicknesses ( T IGZO ) are investigated. As the T IGZO increased, the turn-on voltage ( V on ) decreased, while the subthreshold swing slightly increased. Furthermore, the mobility of over 13 cm²·V −1 ·s −1 and the negligible hysteresis of ~0.5 V are obtained in all of the a-IGZO TFTs, regardless of the T IGZO . The PBS results exhibit that the V on shift is aggravated as the T IGZO decreases. In addition, the DCS-induced instability in the a-IGZO TFTs with various T IGZO values is revealed using current–voltage and capacitance–voltage ( C – V ) measurements. An anomalous hump phenomenon is only observed in the off state of the gate-to-source ( C gs ) curve for all of the a-IGZO TFTs. This is due to the impact ionization that occurs near the drain side of the channel and the generated holes that flow towards the source side along the back-channel interface under the lateral electric field, which cause a lowered potential barrier near the source side. As the T IGZO value increased, the hump in the off state of the C gs curve was gradually weakened.

  14. Quantum confinement effects and source-to-drain tunneling in ultra-scaled double-gate silicon n-MOSFETs

    International Nuclear Information System (INIS)

    Jiang Xiang-Wei; Li Shu-Shen

    2012-01-01

    By using the linear combination of bulk band (LCBB) method incorporated with the top of the barrier splitting (TBS) model, we present a comprehensive study on the quantum confinement effects and the source-to-drain tunneling in the ultra-scaled double-gate (DG) metal—oxide—semiconductor field-effect transistors (MOSFETs). A critical body thickness value of 5 nm is found, below which severe valley splittings among different X valleys for the occupied charge density and the current contributions occur in ultra-thin silicon body structures. It is also found that the tunneling current could be nearly 100% with an ultra-scaled channel length. Different from the previous simulation results, it is found that the source-to-drain tunneling could be effectively suppressed in the ultra-thin body thickness (2.0 nm and below) by the quantum confinement and the tunneling could be suppressed down to below 5% when the channel length approaches 16 nm regardless of the body thickness. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  15. Thermal-fluid analysis of the fill and drain operations of a cryrogenic fuel tank

    Science.gov (United States)

    Stephens, Craig A.; Hanna, Gregory J.; Gong, Leslie

    1993-01-01

    The Generic Research Cryogenic Tank was designed to establish techniques for testing and analyzing the behavior of reusable fuel tank structures subjected to cryogenic fuels and aerodynamic heating. The Generic Research Cryogenic Tank tests will consist of filling a pressure vessel to a prescribed fill level, waiting for steady-state conditions, then draining the liquid while heating the external surface to simulate the thermal environment associated with hypersonic flight. Initial tests of the Generic Research Cryogenic Tank will use liquid nitrogen with future tests requiring liquid hydrogen. Two-dimensional finite-difference thermal-fluid models were developed for analyzing the behavior of the Generic Research Cryogenic Tank during fill and drain operations. The development and results of the two-dimensional fill and drain models, using liquid nitrogen, are provided, along with results and discussion on extrapolating the model results to the operation of the full-size Generic Research Cryogenic Tank. These numerical models provided a means to predict the behavior of the Generic Research Cryogenic Tank during testing and to define the requirements for the Generic Research Cryogenic Tank support systems such as vent, drain, pressurization, and instrumentation systems. In addition, the fill model provided insight into the unexpected role of circumferential conduction in cooling the Generic Research Cryogenic Tank pressure vessel during fill operations.

  16. Penrose Drain Migration After Laparoscopic Surgery

    Directory of Open Access Journals (Sweden)

    Pazouki AbdolReza

    2009-05-01

    Full Text Available Laparoscopy has made a revolution in surgical procedures and treatment of various diseases but its complications are still under investigation. Intra-abdominal visceral and vessel injuries, trocar site hernia, and leaving foreign bodies into the peritoneal cavity are among some laparoscopic surgery complications. This is a rare report of Penrose drain migration following incomplete laparoscopic Fundoplication surgery. The patient was a 47- year- old woman, who was a candidate for Touplet Fundoplication via laparoscopic approach due to refractory gastro-esophageal reflux disease (GERD. While wrapping a Penrose drain around the esophagus, the patient had a cardiorespiratory arrest. Attempts to remove the Penrose drain were unsuccessful and the surgical procedure was terminated due to patient's condition. Four months later, after a long period of dysphagia and abdominal pain, the Penrose drain was defecated via rectum.

  17. On the accuracy of current TCAD hot carrier injection models in nanoscale devices

    Science.gov (United States)

    Zaka, Alban; Rafhay, Quentin; Iellina, Matteo; Palestri, Pierpaolo; Clerc, Raphaël; Rideau, Denis; Garetto, Davide; Dornel, Erwan; Singer, Julien; Pananakakis, Georges; Tavernier, Clément; Jaouen, Hervé

    2010-12-01

    In this work, the hot electron injection models presently available for technology support have been investigated within the context of the development of advanced embedded non-volatile memories. The distribution functions obtained by these models (namely the Fiegna Model - FM [1], the Lucky Electron Model - LEM [2] and the recently implemented Spherical Harmonics Expansion of the Boltzman's Transport Equation - SHE [3]), have been systematically compared to rigorous Monte Carlo (MC) results [4], both in homogeneous and device conditions. Gate-to-drain current ratio and gate current density simulation has also been benchmarked in device simulations. Results indicate that local models such as FM, can partially capture the channel hot electron injection, at the price of model parameter adjustments. Moreover, at least in the device and field condition considered in this work, an overall better agreement with MC simulations has been obtained using the 1st order SHE, even without any particular fitting procedure. Extending the results presented in [3] by exploring shorter gate lengths and addressing the floating gate voltage dependence of the gate current, this work shows that the SHE method could contribute to bridge the gap between the rigorous but time consuming MC method and less rigorous but suitable TCAD local models.

  18. The health workforce crisis: the brain drain scourge.

    Science.gov (United States)

    Ike, Samuel O

    2007-01-01

    The magnitude of the health workforce crisis engendered by brain drain particularly in Africa, and nay more especially Nigeria, has been assuming increasingly alarming proportions in the past three decades. The challenge it poses in meeting the manpower needs in the healthcare sector as well as in the larger economy of the sending countries is enormous. This paper thus sets out to highlight the scope of this brain drain, its effects and the reasons sustaining it, as well as makes concrete suggestions to help stern the tide. A review of the literature on brain drain with particular emphasis on the health workforce sector was done, with focus on Africa, and specifically Nigeria. Literature search was done using mainly the Medline, as well as local journals. The historical perspectives, with the scope of external and internal brain drain are explored. The glaring effects of brain drain both in the global workforce terrain and specifically in the health sectors are portrayed. The countries affected most and the reasons for brain drain are outlined. Strategic steps to redress the brain drain crisis are proffered in this paper. The health workforce crisis resulting from brain drain must be brought to the front-burner of strategic policy decisions leading to paradigm shift in political, social and economic conditions that would serve as incentives to curb the scourge.

  19. Source-Drain Punch-Through Analysis of High Voltage Off-State AlGaN/GaN HEMT Breakdown

    Science.gov (United States)

    Jiang, H.; Li, X.; Wang, J.; Zhu, L.; Wang, H.; Liu, J.; Wang, M.; Yu, M.; Wu, W.; Zhou, Y.; Dai, G.

    2017-06-01

    AlGaN/GaN high-electron mobility transistor’s (HEMT’s) off-state breakdown is investigated using conventional three-terminal off-state breakdown I-V measurement. Competition between gate leakage and source-injection buffer leakage (SIBL) is discussed in detail. It is found that the breakdown is dominated by source-injection which is sensitive to gate voltage and gate length at large gate-to-drain spacing (Lgd > 7μm), where a threshold drain voltage of the occurrence of the SIBL current in GaN buffer exists, and after this threshold voltage the SIBL current continually increased till the buffer breakdown. Our analysis showed that due to the punch-through effect in the buffer, a potential barrier between 2DEG and GaN buffer at the source side mainly controlled by the drain voltage determines the buffer leakage current and the occurrence of the following buffer breakdown, which could explain the experimentally observed breakdown phenomenon.

  20. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  1. Device for discharging drain in a control rod driving apparatus

    International Nuclear Information System (INIS)

    Ikeda, Tadasu; Ikuta, Takuzo; Yoshida, Tomiji; Tsukahara, Katsumi.

    1975-01-01

    Object: To efficiently and safely collect and discharge drain by a simple construction in which a drain cover and a drain tank in a control rod driving apparatus are integrally formed, and an overhauling wrench of said apparatus and a drain hose are mounted on the drain tank. Structure: When a mounting bolt is untightened by a torque wrench so as to be removed from a flange surface of the control rod driving apparatus in a nuclear reactor, axial movement of said apparatus is absorbed by a spring so that drain containing a radioactive material is discharged into a drain tank through the flange surface of said apparatus and is then guided into a collecting tank through a drain hose. (Kamimura, M.)

  2. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  3. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    Science.gov (United States)

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  4. Laparoscopic radical prostatectomy: omitting a pelvic drain

    Directory of Open Access Journals (Sweden)

    David Canes

    2008-03-01

    Full Text Available PURPOSE: Our goal was to assess outcomes of a selective drain placement strategy during laparoscopic radical prostatectomy (LRP with a running urethrovesical anastomosis (RUVA using cystographic imaging in all patients. Materials and Methods: A retrospective chart review was performed for all patients undergoing LRP between January 2003 and December 2004. The anastomosis was performed using a modified van Velthoven technique. A drain was placed at the discretion of the senior surgeon when a urinary leak was demonstrated with bladder irrigation, clinical suspicion for a urinary leak was high, or a complex bladder neck reconstruction was performed. Routine postoperative cystograms were obtained. RESULTS: 208 patients underwent LRP with a RUVA. Data including cystogram was available for 206 patients. The overall rate of cystographic urine leak was 5.8%. A drain was placed in 51 patients. Of these, 8 (15.6% had a postoperative leak on cystogram. Of the 157 undrained patients, urine leak was radiographically visible in 4 (2.5%. The higher leak rate in the drained vs. undrained cohort was statistically significant (p = 0.002. Twenty-four patients underwent pelvic lymph node dissection (8 drained, 16 undrained. Three undrained patients developed lymphoceles, which presented clinically on average 3 weeks postoperatively. There were no urinomas or hematomas in either group. CONCLUSIONS: Routine placement of a pelvic drain after LRP with a RUVA is not necessary, unless the anastomotic integrity is suboptimal intraoperatively. Experienced clinical judgment is essential and accurate in identifying patients at risk for postoperative leakage. When suspicion is low, omitting a drain does not increase morbidity.

  5. 46 CFR 45.157 - Scuppers and gravity drains.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scuppers and gravity drains. 45.157 Section 45.157 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES GREAT LAKES LOAD LINES Conditions of Assignment § 45.157 Scuppers and gravity drains. Scuppers and gravity deck drains from spaces...

  6. PEAT-CO2. Assessment of CO2 emissions from drained peatlands in SE Asia

    International Nuclear Information System (INIS)

    Hooijer, A.; Silvius, M.; Woesten, H.; Page, S.

    2006-12-01

    Forested tropical peatlands in SE Asia store at least 42,000 Megatonnes of soil carbon. This carbon is increasingly released to the atmosphere due to drainage and fires associated with plantation development and logging. Peatlands make up 12% of the SE Asian land area but account for 25% of current deforestation. Out of 27 million hectares of peatland, 12 million hectares (45%) are currently deforested and mostly drained. One important crop in drained peatlands is palm oil, which is increasingly used as a biofuel in Europe. In the PEAT-CO2 project, present and future emissions from drained peatlands were quantified using the latest data on peat extent and depth, present and projected land use and water management practice, decomposition rates and fire emissions. It was found that current likely CO2 emissions caused by decomposition of drained peatlands amounts to 632 Mt/y (between 355 and 874 Mt/y). This emission will increase in coming decades unless land management practices and peatland development plans are changed, and will continue well beyond the 21st century. In addition, over 1997-2006 an estimated average of 1400 Mt/y in CO2 emissions was caused by peatland fires that are also associated with drainage and degradation. The current total peatland CO2 emission of 2000 Mt/y equals almost 8% of global emissions from fossil fuel burning. These emissions have been rapidly increasing since 1985 and will further increase unless action is taken. Over 90% of this emission originates from Indonesia, which puts the country in 3rd place (after the USA and China) in the global CO2 emission ranking. It is concluded that deforested and drained peatlands in SE Asia are a globally significant source of CO2 emissions and a major obstacle to meeting the aim of stabilizing greenhouse gas emissions, as expressed by the international community. It is therefore recommended that international action is taken to help SE Asian countries, especially Indonesia, to better conserve

  7. Modeling of current consumption in 802.15.4/ZigBee sensor motes.

    Science.gov (United States)

    Casilari, Eduardo; Cano-García, Jose M; Campos-Garrido, Gonzalo

    2010-01-01

    Battery consumption is a key aspect in the performance of wireless sensor networks. One of the most promising technologies for this type of networks is 802.15.4/ZigBee. This paper presents an empirical characterization of battery consumption in commercial 802.15.4/ZigBee motes. This characterization is based on the measurement of the current that is drained from the power source under different 802.15.4 communication operations. The measurements permit the definition of an analytical model to predict the maximum, minimum and mean expected battery lifetime of a sensor networking application as a function of the sensor duty cycle and the size of the sensed data.

  8. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    Directory of Open Access Journals (Sweden)

    Ayhan GENCLER

    2009-07-01

    Full Text Available Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems that, in general, developing or underdeveloped countries experience the negative consequences of the brain drain and suffer from the decreases in their human capital. The paper explains the phenomenon of skilled international migration, or brain drain, and summarizes the main global trends in this area.

  9. The management of vacuum neck drains in head and neck surgery and the comparison of two different practice protocols for drain removal.

    Science.gov (United States)

    Kasbekar, A V; Davies, F; Upile, N; Ho, M W; Roland, N J

    2016-01-01

    Introduction The management of vacuum neck drains in head and neck surgery is varied. We aimed to improve early drain removal and therefore patient discharge in a safe and effective manner. Methods The postoperative management of head and neck surgical patients with vacuum neck drains was reviewed retrospectively. A new policy was then implemented to measure drainage three times daily (midnight, 6am, midday). The decision for drain removal was based on the most recent drainage period (at Measuring drainage volumes three times daily allows for more accurate assessment of wound drainage, and this can lead to earlier removal of neck drains and safe discharge.

  10. Fallopian Tube Herniation through Left Sided Abdominal Drain Site.

    Science.gov (United States)

    Hussain, Khalid; Masood, Jovaria

    2016-06-01

    Intra-abdominal drains have been used since long to prevent intra-abdominal collection, and detect any anastomotic leaks. We report a case of left sided fallopian tube herniation from a left lower abdominal drain site in a 27-year female who underwent caesarian section for breach presentation. Several complications related to drain usage has been described but left sided fallopian tube prolapse through drain site has not been reported in literature.

  11. Improvement in the performance of graphene nanoribbon p-i-n tunneling field effect transistors by applying lightly doped profile on drain region

    Science.gov (United States)

    Naderi, Ali

    2017-12-01

    In this paper, an efficient structure with lightly doped drain region is proposed for p-i-n graphene nanoribbon field effect transistors (LD-PIN-GNRFET). Self-consistent solution of Poisson and Schrödinger equation within Nonequilibrium Green’s function (NEGF) formalism has been employed to simulate the quantum transport of the devices. In proposed structure, source region is doped by constant doping density, channel is an intrinsic GNR, and drain region contains two parts with lightly and heavily doped doping distributions. The important challenge in tunneling devices is obtaining higher current ratio. Our simulations demonstrate that LD-PIN-GNRFET is a steep slope device which not only reduces the leakage current and current ratio but also enhances delay, power delay product, and cutoff frequency in comparison with conventional PIN GNRFETs with uniform distribution of impurity and with linear doping profile in drain region. Also, the device is able to operate in higher drain-source voltages due to the effectively reduced electric field at drain side. Briefly, the proposed structure can be considered as a more reliable device for low standby-power logic applications operating at higher voltages and upper cutoff frequencies.

  12. Brain drain: a challenge to global mental health

    OpenAIRE

    Oladeji, Bibilola D.; Gureje, Oye

    2016-01-01

    The brain drain of medical professionals from lower-income to higher-income countries contributes to the current inequity that characterises access to mental healthcare by those in need across the world and hinders efforts to scale up mental health services in resource-constrained settings, especially in Nigeria and other West African countries. The migration of skilled workers is driven by a combination of the globalisation of the labour market and the ability of highly resourced countries t...

  13. Three-dimensional modelling of an embankment built on a soft soil improved with prefabricated vertical drains

    OpenAIRE

    Venda Oliveira, P.J.; Cruz, R.F.P.M.L.; Lemos, L.J.L.; Almeida e Sousa, J.N.V.

    2015-01-01

    This work compares the field measurements of a non-symmetric embankment built on a Portuguese soft soil improved with prefabricated vertical drains (PVDs), with the numerical predictions of a 3D modelling where the PVDs are simulated according to the field flow conditions. The change in the permeability with the void ratio and the effect of the smear zone are also included in the numerical analysis. The numerical predictions are compared with the field data in terms of settlement, horizontal ...

  14. Origin of the water drained by the tunnel Graton

    International Nuclear Information System (INIS)

    Plata B, A.

    1992-12-01

    The research of the origin of the water drained by the Graton tunnel was attempted using isotope techniques. During the period of studies (April 1989-October 1992), four field work was executed to sample waters for chemistry, stable isotope and Tritium analysis, an to inject tracers and verify the possible infiltration from the Rimac and Blanco rivers to the tunnel. The results of the stable isotope analysis show that the water drained by the Graton tunnel comes from a basin around 300 meters above the average altitude of the basin where the Graton is located. The Tritium analysis show that the water is relatively modern. Using the model of total mixing, the residence times of the water drained at the km 0.5 and 2.5 are in the order to 45 years. The conductivities of the water of the tunnel is higher than the Rimac river ones because the influence of mine water. The chemical analysis of the water sampled at the downstream end of the tunnel, show that the conservative ions of the water kept almost constant during more than two years. The results of the work with artificial tracer show that there is no significant leakage from the Rimac and Blanco rivers to the Graton tunnel. So far, it can be concluded as a preliminary approach that the Graton tunnel drains relatively modern water originated in another basin. The hydrodynamics of the area of study seems to include a large storage on underground water in the system. The topography, geology and isotopic composition of the water samples, points to the upper Mantaro river basin as the possible source of part of the water drained by the Graton tunnel. (authors). 20 p. 2 figs., 7 ills., 4 tabs

  15. Mechanism of improving forward and reverse blocking voltages in AlGaN/GaN HEMTs by using Schottky drain

    International Nuclear Information System (INIS)

    Zhao Sheng-Lei; Mi Min-Han; Luo Jun; Wang Yi; Dai Yang; Zhang Jin-Cheng; Ma Xiao-Hua; Hao Yue; Hou Bin

    2014-01-01

    In this paper, we demonstrate that a Schottky drain can improve the forward and reverse blocking voltages (BVs) simultaneously in AlGaN/GaN high-electron mobility transistors (HEMTs). The mechanism of improving the two BVs is investigated by analysing the leakage current components and by software simulation. The forward BV increases from 72 V to 149 V due to the good Schottky contact morphology. During the reverse bias, the buffer leakage in the Ohmicdrain HEMT increases significantly with the increase of the negative drain bias. For the Schottky-drain HEMT, the buffer leakage is suppressed effectively by the formation of the depletion region at the drain terminal. As a result, the reverse BV is enhanced from −5 V to −49 V by using a Schottky drain. Experiments and the simulation indicate that a Schottky drain is desirable for power electronic applications. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  16. Flow and transport processes in a macroporous subsurface-drained glacial till soil

    DEFF Research Database (Denmark)

    Villholth, Karen G.; Jensen, Karsten Høgh

    1998-01-01

    disturbance and compaction of the soil surface. Hypothetically introducing fully surface-connected macropores into the calibrated model resulted in a 22% increase in the loss of solute to the drain, indicating the significance of the hydraulic conditions at the soil surface and the model specification thereof......The experimental results from a field-scale tracer experiment in a subsurface-drained glacial till soil were analyzed by the application of a single/dual porosity model (MACRO), optionally accounting for concurrent and interacting flow and transport in the bulk soil porosity as well...... concentration. The exchange was overpredicted and too rapid when the soil aggregate size (distance between macropores) obtained from an image analysis of soil cores was used in the model. On this basis, the model assumption of instant equilibration of the solute across the matrix porosity, disregarding small...

  17. Fallopian Tube Herniation: An Unusual Complication of Surgical Drain

    OpenAIRE

    Sharma, Lipi; Singh, Alpana; Bhaskaran, Sruthi; Radhika, A. G.; Radhakrishnan, Gita

    2012-01-01

    Background. Surgical drains have been used since time immemorial, but their use is not without complications. By presenting this case we aim to describe an uncommon complication of herniation of fallopian tube following the simple procedure of surgical drain removal. Case Presentation. This case describes a 23-year G2P1L1 who underwent an emergency cesarean section for obstructed labor with intraperitoneal drain insertion. The patient had an uneventful postoperative period, drain was removed ...

  18. An analytic current-voltage model for quasi-ballistic III-nitride high electron mobility transistors

    Science.gov (United States)

    Li, Kexin; Rakheja, Shaloo

    2018-05-01

    We present an analytic model to describe the DC current-voltage (I-V) relationship in scaled III-nitride high electron mobility transistors (HEMTs) in which transport within the channel is quasi-ballistic in nature. Following Landauer's transport theory and charge calculation based on two-dimensional electrostatics that incorporates negative momenta states from the drain terminal, an analytic expression for current as a function of terminal voltages is developed. The model interprets the non-linearity of access regions in non-self-aligned HEMTs. Effects of Joule heating with temperature-dependent thermal conductivity are incorporated in the model in a self-consistent manner. With a total of 26 input parameters, the analytic model offers reduced empiricism compared to existing GaN HEMT models. To verify the model, experimental I-V data of InAlN/GaN with InGaN back-barrier HEMTs with channel lengths of 42 and 105 nm are considered. Additionally, the model is validated against numerical I-V data obtained from DC hydrodynamic simulations of an unintentionally doped AlGaN-on-GaN HEMT with 50-nm gate length. The model is also verified against pulsed I-V measurements of a 150-nm T-gate GaN HEMT. Excellent agreement between the model and experimental and numerical results for output current, transconductance, and output conductance is demonstrated over a broad range of bias and temperature conditions.

  19. Thailand and brain drain

    Directory of Open Access Journals (Sweden)

    Terry Commins

    2009-01-01

    Full Text Available Brain drain has been the subject of research since the 1960s. This research has been hampered by a lack of accurate data from both source and receiving countries on migration and on the losses and gains to developing economies of skilled migration. However, despite these handicaps, research has been able to clearly show that trends are changing and the effect this is having is usually quite different for individual source countries.Thailand, as a developing economy, could be regarded as a source country. Fortunately, Thailand has never ranked highly in terms of brain drain when compared to other states in Asia and while it may not be a significant problem it nonetheless needs to be monitored. Thailand is also somewhat unique in that the migration that has occurred has been almost equally split between secondary and tertiary educated Thais. Thailand also ranks low in terms of tertiary educated population who have migrated when compared to other countries in the region. Globalisation is having a profound effect on the migration of skilled workers. As trade becomes increasingly free, barriers to the movement of services or people are also freed. As the better educated are encouraged to think globally, so too will they be inclined to move globally into the world community.This paper examines Thailand’s position with respect to brain drain, some of the lessons we have learned and some of the steps that are being taken to minimise the impact of the loss of skilled workers, with a particular focus on science and technology. The conclusion is that brain drain should not be viewed as an entirely negative development and that the positive outcomes should be recognised, encouraged and incorporated into policy.

  20. Modeling of Current Consumption in 802.15.4/ZigBee Sensor Motes

    Directory of Open Access Journals (Sweden)

    Eduardo Casilari

    2010-06-01

    Full Text Available Battery consumption is a key aspect in the performance of wireless sensor networks. One of the most promising technologies for this type of networks is 802.15.4/ZigBee. This paper presents an empirical characterization of battery consumption in commercial 802.15.4/ZigBee motes. This characterization is based on the measurement of the current that is drained from the power source under different 802.15.4 communication operations. The measurements permit the definition of an analytical model to predict the maximum, minimum and mean expected battery lifetime of a sensor networking application as a function of the sensor duty cycle and the size of the sensed data.

  1. Effects of annealing gas and drain doping concentration on electrical properties of Ge-source/Si-channel heterojunction tunneling FETs

    Science.gov (United States)

    Bae, Tae-Eon; Wakabayashi, Yuki; Nakane, Ryosho; Takenaka, Mitsuru; Takagi, Shinichi

    2018-04-01

    Improvement in the performance of Ge-source/Si-channel heterojunction tunneling FETs (TFETs) with high on-current/off-current (I on/I off) ratio and steep subthreshold swing (SS) is demonstrated. In this paper, we experimentally examine the effects of gas ambient [N2 and forming gas (4% H2/N2)] and a doping concentration in the drain regions on the electrical characteristics of Ge/Si heterojunction TFETs. The minimum SS (SSmin) of 70.9 mV/dec and the large I on/I off ratio of 1.4 × 107 are realized by postmetallization annealing in forming gas. Also, the steep SSmin and averaged SS (SSavr) values of 64.2 and 78.4 mV/dec, respectively, are obtained in low drain doping concentration. This improvement is attributable to the reduction in interface state density (D it) in the channel region and to the low leakage current in the drain region.

  2. Drain Insertion in Chronic Subdural Hematoma: An International Survey of Practice.

    Science.gov (United States)

    Soleman, Jehuda; Kamenova, Maria; Lutz, Katharina; Guzman, Raphael; Fandino, Javier; Mariani, Luigi

    2017-08-01

    To investigate whether, after the publication of grade I evidence that it reduces recurrence rates, the practice of drain insertion after burr-hole drainage of chronic subdural hematoma has changed. Further, we aimed to document various practice modalities concerning the insertion of a drain adopted by neurosurgeons internationally. We administered a survey to neurosurgeons worldwide with questions relating to the surgical treatment of chronic subdural hematoma, with an emphasis on their practices concerning the use of a drain. The preferred surgical technique was burr-hole drainage (89%). Most surgeons prefer to place a drain (80%), whereas in 56% of the cases the reason for not placing a drain was brain expansion after evacuation. Subdural drains are placed by 50% and subperiosteal drains by 27% of the responders, whereas 23% place primarily a subdural drain if possible and otherwise a subperiosteal drain. Three quarters of the responders leave the drain for 48 hours and give prophylactic antibiotic treatment, mostly a single-shot dose intraoperatively (70%). Routine postoperative computed tomography is done by 59% mostly within 24-48 hours after surgery (94%). Adjunct treatment to surgery rarely is used (4%). The publication of grade I evidence in favor of drain use influenced positively this practice worldwide. Some surgeons are still reluctant to insert a drain, especially when the subdural space is narrow after drainage of the hematoma. The insertion of a subperiosteal drain could be a good alternative solution. However, its outcome and efficacy must be evaluated in larger studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. A study of the complications of small bore 'Seldinger' intercostal chest drains.

    Science.gov (United States)

    Davies, Helen E; Merchant, Shairoz; McGown, Anne

    2008-06-01

    Use of small bore chest drains (drainage over a 12-month period. One hundred consecutive small bore Seldinger (12F) chest drain insertions were evaluated. Few serious complications occurred. However, 21% of the chest drains were displaced ('fell out') and 9% of the drains became blocked. This contributed to high morbidity rates, with 13% of patients requiring repeat pleural procedures. The frequency of drain blockage in pleural effusion was reduced by administration of regular normal saline drain flushes (odds ratio for blockage in flushed drains compared with non-flushed drains 0.04, 95% CI: 0.01-0.37, P < 0.001). Regular chest drain flushes are advocated in order to reduce rates of drain blockage, and further studies are needed to determine optimal fixation strategies that may reduce associated patient morbidity.

  4. Combining Microbial Enzyme Kinetics Models with Light Use Efficiency Models to Predict CO2 and CH4 Ecosystem Exchange from Flooded and Drained Peatland Systems

    Science.gov (United States)

    Oikawa, P. Y.; Jenerette, D.; Knox, S. H.; Sturtevant, C. S.; Verfaillie, J. G.; Baldocchi, D. D.

    2014-12-01

    Under California's Cap-and-Trade program, companies are looking to invest in land-use practices that will reduce greenhouse gas (GHG) emissions. The Sacramento-San Joaquin River Delta is a drained cultivated peatland system and a large source of CO2. To slow soil subsidence and reduce CO2 emissions, there is growing interest in converting drained peatlands to wetlands. However, wetlands are large sources of CH4 that could offset CO2-based GHG reductions. The goal of our research is to provide accurate measurements and model predictions of the changes in GHG budgets that occur when drained peatlands are restored to wetland conditions. We have installed a network of eddy covariance towers across multiple land use types in the Delta and have been measuring CO2 and CH4 ecosystem exchange for multiple years. In order to upscale these measurements through space and time we are using these data to parameterize and validate a process-based biogeochemical model. To predict gross primary productivity (GPP), we are using a simple light use efficiency (LUE) model which requires estimates of light, leaf area index and air temperature and can explain 90% of the observed variation in GPP in a mature wetland. To predict ecosystem respiration we have adapted the Dual Arrhenius Michaelis-Menten (DAMM) model. The LUE-DAMM model allows accurate simulation of half-hourly net ecosystem exchange (NEE) in a mature wetland (r2=0.85). We are working to expand the model to pasture, rice and alfalfa systems in the Delta. To predict methanogenesis, we again apply a modified DAMM model, using simple enzyme kinetics. However CH4 exchange is complex and we have thus expanded the model to predict not only microbial CH4 production, but also CH4 oxidation, CH4 storage and the physical processes regulating the release of CH4 to the atmosphere. The CH4-DAMM model allows accurate simulation of daily CH4 ecosystem exchange in a mature wetland (r2=0.55) and robust estimates of annual CH4 budgets. The LUE

  5. Managing Artificially Drained Low-Gradient Agricultural Headwaters for Enhanced Ecosystem Functions

    Science.gov (United States)

    Pierce, Samuel C.; Kröger, Robert; Pezeshki, Reza

    2012-01-01

    Large tracts of lowlands have been drained to expand extensive agriculture into areas that were historically categorized as wasteland. This expansion in agriculture necessarily coincided with changes in ecosystem structure, biodiversity, and nutrient cycling. These changes have impacted not only the landscapes in which they occurred, but also larger water bodies receiving runoff from drained land. New approaches must append current efforts toward land conservation and restoration, as the continuing impacts to receiving waters is an issue of major environmental concern. One of these approaches is agricultural drainage management. This article reviews how this approach differs from traditional conservation efforts, the specific practices of drainage management and the current state of knowledge on the ecology of drainage ditches. A bottom-up approach is utilized, examining the effects of stochastic hydrology and anthropogenic disturbance on primary production and diversity of primary producers, with special regard given to how management can affect establishment of macrophytes and how macrophytes in agricultural landscapes alter their environment in ways that can serve to mitigate non-point source pollution and promote biodiversity in receiving waters. PMID:24832519

  6. Managing Artificially Drained Low-Gradient Agricultural Headwaters for Enhanced Ecosystem Functions

    Directory of Open Access Journals (Sweden)

    Reza Pezeshki

    2012-12-01

    Full Text Available Large tracts of lowlands have been drained to expand extensive agriculture into areas that were historically categorized as wasteland. This expansion in agriculture necessarily coincided with changes in ecosystem structure, biodiversity, and nutrient cycling. These changes have impacted not only the landscapes in which they occurred, but also larger water bodies receiving runoff from drained land. New approaches must append current efforts toward land conservation and restoration, as the continuing impacts to receiving waters is an issue of major environmental concern. One of these approaches is agricultural drainage management. This article reviews how this approach differs from traditional conservation efforts, the specific practices of drainage management and the current state of knowledge on the ecology of drainage ditches. A bottom-up approach is utilized, examining the effects of stochastic hydrology and anthropogenic disturbance on primary production and diversity of primary producers, with special regard given to how management can affect establishment of macrophytes and how macrophytes in agricultural landscapes alter their environment in ways that can serve to mitigate non-point source pollution and promote biodiversity in receiving waters.

  7. An Analytical Threshold Voltage Model of Fully Depleted (FD) Recessed-Source/Drain (Re-S/D) SOI MOSFETs with Back-Gate Control

    Science.gov (United States)

    Saramekala, Gopi Krishna; Tiwari, Pramod Kumar

    2016-10-01

    This paper presents an analytical threshold voltage model for back-gated fully depleted (FD), recessed-source drain silicon-on-insulator metal-oxide-semiconductor field-effect transistors (MOSFETs). Analytical surface potential models have been developed at front and back surfaces of the channel by solving the two-dimensional (2-D) Poisson's equation in the channel region with appropriate boundary conditions assuming a parabolic potential profile in the transverse direction of the channel. The strong inversion criterion is applied to the front surface potential as well as on the back one in order to find two separate threshold voltages for front and back channels of the device, respectively. The device threshold voltage has been assumed to be associated with the surface that offers a lower threshold voltage. The developed model was analyzed extensively for a variety of device geometry parameters like the oxide and silicon channel thicknesses, the thickness of the source/drain extension in the buried oxide, and the applied bias voltages with back-gate control. The proposed model has been validated by comparing the analytical results with numerical simulation data obtained from ATLAS™, a 2-D device simulator from SILVACO.

  8. Modeling of Dual Gate Material Hetero-dielectric Strained PNPN TFET for Improved ON Current

    Science.gov (United States)

    Kumari, Tripty; Saha, Priyanka; Dash, Dinesh Kumar; Sarkar, Subir Kumar

    2018-01-01

    The tunnel field effect transistor (TFET) is considered to be a promising alternative device for future low-power VLSI circuits due to its steep subthreshold slope, low leakage current and its efficient performance at low supply voltage. However, the main challenging issue associated with realizing TFET for wide scale applications is its low ON current. To overcome this, a dual gate material with the concept of dielectric engineering has been incorporated into conventional TFET structure to tune the tunneling width at source-channel interface allowing significant flow of carriers. In addition to this, N+ pocket is implanted at source-channel junction of the proposed structure and the effect of strain is added for exploring the performance of the model in nanoscale regime. All these added features upgrade the device characteristics leading to higher ON current, low leakage and low threshold voltage. The present work derives the surface potential, electric field expression and drain current by solving 2D Poisson's equation at different boundary conditions. A comparative analysis of proposed model with conventional TFET has been done to establish the superiority of the proposed structure. All analytical results have been compared with the results obtained in SILVACO ATLAS device simulator to establish the accuracy of the derived analytical model.

  9. Sampling and analysis plan (SAP) for WESF drains and TK-100 sump

    International Nuclear Information System (INIS)

    Simmons, F.M.

    1998-01-01

    The intent of this project is to determine whether the Waste Encapsulation and Storage Facility (WESF) floor drain piping and the TK-100 sump are free from contamination. TK-100 is currently used as a catch tank to transfer low level liquid waste from WESF to Tank Farms via B Plant. This system is being modified as part of the WESF decoupling since B Plant is being deactivated. As a result of the 1,1,1-trichloroethane (TCA) discovery in TK-100, the associated WESF floor drains and the pit sump need to be sampled. Breakdown constituents have been reviewed and found to be non-hazardous. There are 29 floor drains that tie into a common header leading into the tank. To prevent high exposure during sampling of the drains, TK-100 will be removed into the B Plant canyon and a new tank will be placed in the pit before any floor drain samples are taken. The sump will be sampled prior to TK-100 removal. A sample of the sludge and any liquid in the sump will be taken and analyzed for TCA and polychlorinated biphenyl (PCB). After the sump has been sampled, the vault floor will be flushed. The flush will be transferred from the sump into TK-100. TK-100 will be moved into B Plant. The vault will then be cleaned of debris and visually inspected. If there is no visual indication of TCA or PCB staining, the vault will be painted and a new tank installed. If there is an indication of TCA or PCB from laboratory analysis or staining, further negotiations will be required to determine a path forward. A total of 8 sets of three 40ml samples will be required for all of the floor drains and sump. The sump set will include one 125ml solid sample. The only analysis required will be for TCA in liquids. PCBs will be checked in sump solids only. The Sampling and Analysis Plan (SAP) is written to provide direction for the sampling and analytical activities of the 29 WESF floor drains and the TK-100 sump. The intent of this plan is to define the responsibilities of the various organizations

  10. Method of processing laundry drain

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Y; Oda, A; Yusa, H; Kitamura, M; Horiuchi, S

    1979-09-28

    Purpose: To subject the laundry drain to flocculation precipitation treatment in the prior stage of an inverse osmotic treatment, and subject only the supernatant to the inverse osmotic treatment and the precipitate directly to the condensation treatment, thereby decreasing the frequency of exchange of the inverse osmotic membranes, and reducing the quantity of purifying water. Method: The laundry drain is supplied to a flocculation precipitation tank, and added and mixed with a flocculant and a neutralizing agent, thus being subjected to a flocculation precipitation treatment. The supernatant is transported to a circulation tank through a transportation pipe, and is subjected to an inverse osmotic treatment in inverse osmotic module through the circulation tank, a filter and a high tension pump, and then returned to the circulation tank. The supernatant is thus concentrated to a predetermined concentration by repeating such operations. On the other hand, the precipitate at the bottom part of the flocculation precipitation tank is supplied through the transportation pipe to an evaporator supply tank together with the concentrate from the drain circulation tank, and evaporated and concentrated in the evaporator.

  11. Current fluctuation of electron and hole carriers in multilayer WSe{sub 2} field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Seung-Pil; Shin, Jong Mok; Jang, Ho-Kyun; Jin, Jun Eon; Kim, Gyu-Tae, E-mail: gtkim@korea.ac.kr [School of Electrical Engineering, Korea University, Seoul 02481 (Korea, Republic of); Kim, Yong Jin; Kim, Young Keun [Department of Materials Science and Engineering, Korea University, Seoul 02481 (Korea, Republic of); Shin, Minju [School of Electrical Engineering, Korea University, Seoul 02481 (Korea, Republic of); IMEP-LAHC, Grenoble INP-MINATEC, 3 Parvis Louis Neel, 38016 Grenoble (France)

    2015-12-14

    Two-dimensional materials have outstanding scalability due to their structural and electrical properties for the logic devices. Here, we report the current fluctuation in multilayer WSe{sub 2} field effect transistors (FETs). In order to demonstrate the impact on carrier types, n-type and p-type WSe{sub 2} FETs are fabricated with different work function metals. Each device has similar electrical characteristics except for the threshold voltage. In the low frequency noise analysis, drain current power spectral density (S{sub I}) is inversely proportional to frequency, indicating typical 1/f noise behaviors. The curves of the normalized drain current power spectral density (NS{sub I}) as a function of drain current at the 10 Hz of frequency indicate that our devices follow the carrier number fluctuation with correlated mobility fluctuation model. This means that current fluctuation depends on the trapping-detrapping motion of the charge carriers near the channel interface. No significant difference is observed in the current fluctuation according to the charge carrier type, electrons and holes that occurred in the junction and channel region.

  12. The Brain Drain in Mexico--A Subject for Research...or Agenda?

    Science.gov (United States)

    Aupetit, Sylvie Didou

    2006-01-01

    The purpose of this article is to analyse the present state of the discussion and data regarding the brain drain in Mexico. From current data, recent trends show certain peculiarities in the national picture, pointing to an increase in the number of free movers, and a decrease in the number of young people who obtain Mexican government…

  13. Evisceration of Appendix through the Drain Site: A Rare Case Report.

    Science.gov (United States)

    Ravishankaran, Praveen; Rajamani, A

    2013-06-01

    Placing a drain after surgery is a usual procedure in any emergency abdominal operation. The drain is removed as soon as its purpose of draining the intraabdominal collection in served. Evisceration of intraabdominal organs through the drain site is a rare occurance. This case report is about an 12 year old girl who was admitted with blunt trauma abdomen. After completion of emergency laparotomy a drain was placed in the right lower quadrant. When the drain was removed on the 6th post operative day, the appendix eviscerated out of the drain site. The wound was extended a little and an appendectomy was done. This case is presented for its rarity as only two similar instances have been reported in literature so far.

  14. Modeling the photochemical attenuation of down-the-drain chemicals during river transport by stochastic methods and field measurements of pharmaceuticals and personal care products.

    Science.gov (United States)

    Hanamoto, Seiya; Nakada, Norihide; Yamashita, Naoyuki; Tanaka, Hiroaki

    2013-01-01

    Existing stochastic models for predicting concentrations of down-the-drain chemicals in aquatic environments do not account for the diurnal variation of direct photolysis by sunlight, despite its being an important factor in natural attenuation. To overcome this limitation, we developed a stochastic model incorporating temporal variations in direct photolysis. To verify the model, we measured 57 pharmaceuticals and personal care products (PPCPs) in a 7.6-km stretch of an urban river, and determined their physical and biological properties in laboratory experiments. During transport along the river, 8 PPCPs, including ketoprofen and azithromycin, were attenuated by >20%, mainly owing to direct photolysis and adsorption to sediments. The photolabile PPCPs attenuated significantly in the daytime but persisted in the nighttime. The observations were similar to the values predicted by the photolysis model for the photolabile PPCPs (i.e., ketoprofen, diclofenac and furosemide) but not by the existing model. The stochastic model developed in this study was suggested to be a novel and useful stochastic model for evaluating direct photolysis of down-the-drain chemicals, which occurs during the river transport.

  15. Model of Draining of the Blast Furnace Hearth with an Impermeable Zone

    Science.gov (United States)

    Saxén, Henrik

    2015-02-01

    Due to demands of lower costs and higher productivity in the steel industry, the volume of operating blast furnaces has grown during the last decades. As the height is limited by the allowable pressure drop, the hearth diameter has grown considerably and, along with this, also draining-related problems. In this paper a mathematical model is developed for simulating the drainage in the case where an impermeable region exists in the blast furnace hearth. The model describes the quasi-stationary drainage process of a hearth with two operating tapholes, where the communication between the two pools of molten slag and iron can be controlled by parameterized expressions. The model also considers the case where the buoyancy of the liquids is sufficient for lifting the coke bed. The implications of different size of the liquid pools, communication between the pools, bed porosity, etc. are studied by simulation, and conclusions concerning their effect on the drainage behavior and evolution of the liquid levels in the hearth are drawn. The simulated liquid levels are finally demonstrated to give rise to a pressure profile acting on the hearth which agrees qualitatively with signals from strain gauges mounted in the hearth wall of an industrial ironmaking process.

  16. Band to Band Tunneling (BBT) Induced Leakage Current Enhancement in Irradiated Fully Depleted SOI Devices

    Science.gov (United States)

    Adell, Phillipe C.; Barnaby, H. J.; Schrimpf, R. D.; Vermeire, B.

    2007-01-01

    We propose a model, validated with simulations, describing how band-to-band tunneling (BBT) affects the leakage current degradation in some irradiated fully-depleted SOI devices. The dependence of drain current on gate voltage, including the apparent transition to a high current regime is explained.

  17. Mechanical decontamination techniques for floor drain systems

    International Nuclear Information System (INIS)

    Palau, G.L.

    1987-01-01

    The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used

  18. Brain drain of China and India

    OpenAIRE

    Li, Yuan

    2012-01-01

    Abstract Under the background of globalization, brain drain is a common phenomenon in many countries. Talents flow from developing countries to developed countries, and this phenomenon unavoidably exerts various and profound influences to both the source countries and the receiving countries. This thesis deals with the phenomenon of brain drain with the aim to investigate the phenomenon further and carry out two case studies of China and India. The research method is main...

  19. Drained Triaxial Tests on Eastern Scheldt Sand

    DEFF Research Database (Denmark)

    Praastrup, U.; Jakobsen, Kim Parsberg

    In the process of understanding and developing models for geomaterials, the stress-strain behaviour is commonly studied by performing triaxial tests. In the present study static triaxial tests have been performed to gain knowledge of the stress-strain behaviour of frictional materials during...... monotonic loading. The tests reported herein are all drained tests, starting from different initial states of stress and following various stress paths. AIl the tests are performed on reconstituted medium dense specimens of Eastern Scheldt Sand....

  20. CSER 94-011: Use of glovebags for demister draining operations

    International Nuclear Information System (INIS)

    Hess, A.L.

    1994-01-01

    A criticality safety review is presented for the use of plastic-sheet glovebags for the operations of draining demisters on the 26-inch vacuum system headers. A criticality drain is required because of the possibility for spilling liquid of sufficient volume and fissile content for criticality. It is recommended that the glovebag design include a rigid, 2ft x 2ft floor with a central drain feeding a geometrically favorable spill-catch vessel, plus a screen grid above the bottom for drain protection

  1. Toward the modeling of mucus draining from the human lung: role of the geometry of the airway tree

    International Nuclear Information System (INIS)

    Mauroy, Benjamin; Merckx, Jacques; Flaud, Patrice; Fausser, Christian; Pelca, Dominique

    2011-01-01

    Mucociliary clearance and cough are the two main natural mucus draining methods in the bronchial tree. If they are affected by a pathology, they can become insufficient or even ineffective, then therapeutic draining of mucus plays a critical role to keep mucus levels in the lungs acceptable. The manipulations of physical therapists are known to be very efficient clinically but they are mostly empirical since the biophysical mechanisms involved in these manipulations have never been studied. We develop in this work a model of mucus clearance in idealized rigid human bronchial trees and focus our study on the interaction between (1) tree geometry, (2) mucus physical properties and (3) amplitude of flow rate in the tree. The mucus is considered as a Bingham fluid (gel-like) which is moved upward in the tree thanks to its viscous interaction with air flow. Our studies point out the important roles played both by the geometry and by the physical properties of mucus (yield stress and viscosity). More particularly, the yield stress has to be overcome to make mucus flow. Air flow rate and yield stress determine the maximal possible mucus thickness in each branch of the tree at equilibrium. This forms a specific distribution of mucus in the tree whose characteristics are strongly related to the multi-scaled structure of the tree. The behavior of any mucus distribution is then dependent on this distribution. Finally, our results indicate that increasing air flow rates ought to be more efficient to drain mucus out of the bronchial tree while minimizing patient discomfort

  2. A two-dimensional analytical model for channel potential and threshold voltage of short channel dual material gate lightly doped drain MOSFET

    International Nuclear Information System (INIS)

    Tripathi Shweta

    2014-01-01

    An analytical model for the channel potential and the threshold voltage of the short channel dual-material-gate lightly doped drain (DMG-LDD) metal—oxide—semiconductor field-effect transistor (MOSFET) is presented using the parabolic approximation method. The proposed model takes into account the effects of the LDD region length, the LDD region doping, the lengths of the gate materials and their respective work functions, along with all the major geometrical parameters of the MOSFET. The impact of the LDD region length, the LDD region doping, and the channel length on the channel potential is studied in detail. Furthermore, the threshold voltage of the device is calculated using the minimum middle channel potential, and the result obtained is compared with the DMG MOSFET threshold voltage to show the improvement in the threshold voltage roll-off. It is shown that the DMG-LDD MOSFET structure alleviates the problem of short channel effects (SCEs) and the drain induced barrier lowering (DIBL) more efficiently. The proposed model is verified by comparing the theoretical results with the simulated data obtained by using the commercially available ATLAS™ 2D device simulator. (interdisciplinary physics and related areas of science and technology)

  3. A two-dimensional analytical model for channel potential and threshold voltage of short channel dual material gate lightly doped drain MOSFET

    Science.gov (United States)

    Shweta, Tripathi

    2014-11-01

    An analytical model for the channel potential and the threshold voltage of the short channel dual-material-gate lightly doped drain (DMG-LDD) metal—oxide—semiconductor field-effect transistor (MOSFET) is presented using the parabolic approximation method. The proposed model takes into account the effects of the LDD region length, the LDD region doping, the lengths of the gate materials and their respective work functions, along with all the major geometrical parameters of the MOSFET. The impact of the LDD region length, the LDD region doping, and the channel length on the channel potential is studied in detail. Furthermore, the threshold voltage of the device is calculated using the minimum middle channel potential, and the result obtained is compared with the DMG MOSFET threshold voltage to show the improvement in the threshold voltage roll-off. It is shown that the DMG-LDD MOSFET structure alleviates the problem of short channel effects (SCEs) and the drain induced barrier lowering (DIBL) more efficiently. The proposed model is verified by comparing the theoretical results with the simulated data obtained by using the commercially available ATLAS™ 2D device simulator.

  4. Modelling of parameters for asymmetric halo and symmetric DHDMG n-MOSFETs

    Science.gov (United States)

    De, Swapnadip; Sarkar, Angsuman; Sarkar, Chandan Kumar

    2011-10-01

    This article presents an analytical surface potential, threshold voltage and drain current model for asymmetric pocket-implanted, single-halo dual material gate and double-halo dual material gate (DHDMG) n-MOSFET (MOSFET, metal-oxide-semiconductor field-effect transistor) operating up to 40 nm regime. The model is derived by applying Gauss's law to a rectangular box, covering the entire depletion region. The asymmetric pocket-implanted model takes into account the effective doping concentration of the two linear pocket profiles at the source and the drain ends along with the inner fringing capacitances at both the source and the drain ends and the subthreshold drain and the substrate bias effect. Using the surface potential model, the threshold voltage and drain currents are estimated. The same model is used to find the characteristic parameters for dual-material gate (DMG) with halo implantations and double gate. The characteristic improvement is investigated. It is concluded that the DHDMG device structure exhibits better suppression of the short-channel effect (SCE) and the threshold voltage roll-off than DMG and double-gate MOSFET. The adequacy of the model is verified by comparing with two-dimensional device simulator DESSIS. A very good agreement of our model with DESSIS is obtained proving the validity of our model used in suppressing the SCEs.

  5. Draining after breast reduction: a randomised controlled inter-patient study

    NARCIS (Netherlands)

    Corion, Leonard U. M.; Smeulders, Mark J. C.; van Zuijlen, Paul P. M.; van der Horst, Chantal M. A. M.

    2009-01-01

    One hundred and seven bilateral breast reductions were prospectively randomised during surgery to receive or not receive wound drains. Fifty-five patients were randomised to have a drain and 52 to not have a drain. There was no statistical difference in the number of complications between the

  6. Interim report on the laboratory and theoretical work in modeling the drained and undrained behavior of buffer materials

    International Nuclear Information System (INIS)

    Boergesson, L.

    1990-12-01

    This report describes the continuous work of modeling the geotechnical properties of buffer materials. Some results of laboratory work with drained and undrained tests are described as well as the material models that these test have yielded. The effective stress concept and its relevance is discussed. The technique to apply the models in calculations using the finite element program ABAQUS is described. Some calculations of laboratory verification tests are shown and the results compared. Finally two examples of scenario calculations are shown. The work has led to three material models that can be used in ABAQUS calculations. All parameters for these models are not fully known and a continuation of the work is required. These models are not suitable for all situations and the relevance and need for further developments are presently investigated. (au)

  7. Study of the patency of different peritoneal drains used prophylactically in bariatric surgery.

    Science.gov (United States)

    Salgado Júnior, Wilson; Macedo Neto, Marcelo Martins; dos Santos, José Sebastião; Sakarankutty, Ajith Kumar; Ceneviva, Reginaldo; de Castro e Silva, Orlando

    2009-05-21

    To compare the performance of different types of abdominal drains used in bariatric surgery. A vertical banded Roux-en-Y gastric bypass was performed in 33 morbidly obese patients. Drainage of the peritoneal cavity was performed in each case using three different types of drain selected in a randomized manner: a latex tubular drain, a Watterman tubulolaminar drain, and a silicone channeled drain. Drain permeability, contamination of the drained fluid, ease of handling, and patient discomfort were evaluated postoperatively over a period of 7 d. The patients with the silicone channeled drain had larger volumes of drainage compared to patients with tubular and tubulolaminar drains between the third and seventh postoperative days. In addition, a lower incidence of discomfort and of contamination with bacteria of a more pathogenic profile was observed in the patients with the silicone channeled drain. The silicone channeled drain was more comfortable and had less chance of occlusion, which is important in the detection of delayed dehiscence.

  8. Technology CAD of silicided Schottky barrier MOSFET for elevated source-drain engineering

    International Nuclear Information System (INIS)

    Saha, A.R.; Chattopadhyay, S.; Bose, C.; Maiti, C.K.

    2005-01-01

    Technology CAD has been used to study the performance of a silicided Schottky barrier (SB) MOSFET with gate, source and drain contacts realized with nickel-silicide. Elevated source-drain structures have been used towards the S/D engineering of CMOS devices. A full process-to-device simulation has been employed to predict the performance of sub-micron SB n-MOSFETs for the first time. A model for the diffusion and alloy growth kinetics has been incorporated in SILVACO-ATLAS and ATHENA to explore the processing and design parameter space for the Ni-silicided MOSFETs. The temperature and concentration dependent diffusion model for NiSi have been developed and necessary material parameters for nickel-silicide and epitaxial-Si have been incorporated through the C-interpreter function. Two-dimensional (2D) process-to-device simulations have also been used to study the dc and ac (RF) performance of silicided Schottky barrier (SB) n-MOSFETs. The extracted sheet resistivity, as a function of annealing temperature of the silicided S/D contacts, is found to be lower than the conventional contacts currently in use. It is also shown that the Technology CAD has the full capability to predict the possible dc and ac performance enhancement of a MOSFET with elevated S/D structures. While the simulated dc performance shows a clear enhancement, the RF analyses show no performance degradation in the cut-off frequency/propagation delay and also improve the ac performance due to the incorporation of silicide contacts in the S/D region

  9. Technology CAD of silicided Schottky barrier MOSFET for elevated source-drain engineering

    Energy Technology Data Exchange (ETDEWEB)

    Saha, A.R. [Department of Electronics and ECE, IIT, Kharagpur 721302 (India)]. E-mail: ars.iitkgp@gmail.com; Chattopadhyay, S. [Department of Electronics and ECE, IIT, Kharagpur 721302 (India); School of Electrical, Electronics and Computer Engineering, University of Newcastle, Newcastle upon Tyne (United Kingdom); Bose, C. [Department of Electronics and Telecommunication Engineering, Jadavpur University, Calcutta 700032 (India); Maiti, C.K. [Department of Electronics and ECE, IIT, Kharagpur 721302 (India)

    2005-12-05

    Technology CAD has been used to study the performance of a silicided Schottky barrier (SB) MOSFET with gate, source and drain contacts realized with nickel-silicide. Elevated source-drain structures have been used towards the S/D engineering of CMOS devices. A full process-to-device simulation has been employed to predict the performance of sub-micron SB n-MOSFETs for the first time. A model for the diffusion and alloy growth kinetics has been incorporated in SILVACO-ATLAS and ATHENA to explore the processing and design parameter space for the Ni-silicided MOSFETs. The temperature and concentration dependent diffusion model for NiSi have been developed and necessary material parameters for nickel-silicide and epitaxial-Si have been incorporated through the C-interpreter function. Two-dimensional (2D) process-to-device simulations have also been used to study the dc and ac (RF) performance of silicided Schottky barrier (SB) n-MOSFETs. The extracted sheet resistivity, as a function of annealing temperature of the silicided S/D contacts, is found to be lower than the conventional contacts currently in use. It is also shown that the Technology CAD has the full capability to predict the possible dc and ac performance enhancement of a MOSFET with elevated S/D structures. While the simulated dc performance shows a clear enhancement, the RF analyses show no performance degradation in the cut-off frequency/propagation delay and also improve the ac performance due to the incorporation of silicide contacts in the S/D region.

  10. SLD-MOSCNT: A new MOSCNT with step-linear doping profile in the source and drain regions

    Science.gov (United States)

    Tahne, Behrooz Abdi; Naderi, Ali

    2017-01-01

    In this paper, a new structure, step-linear doping MOSCNT (SLD-MOSCNT), is proposed to improve the performance of basic MOSCNTs. The basic structure suffers from band to band tunneling (BTBT). We show that using SLD profile for source and drain regions increases the horizontal distance between valence and conduction bands at gate to source/drain junction which reduces BTBT probability. SLD performance is compared with other similar structures which have recently been proposed to reduce BTBT such as MOSCNT with lightly-doped drain and source (LDDS), and with double-light doping in source and drain regions (DLD). The obtained results using a nonequilibrium Green’s function (NEGF) method show that the SLD-MOSCNT has the lowest leakage current, power consumption and delay time, and the highest current ratio and voltage gain. The ambipolar conduction in the proposed structure is very low and can be neglected. In addition, these structures can improve short-channel effects. Also, the investigation of cutoff frequency of the different structures shows that the SLD has the highest cutoff frequency. Device performance has been investigated for gate length from 8 to 20 nm which demonstrates all discussions regarding the superiority of the proposed structure are also valid for different channel lengths. This improvement is more significant especially for channel length less than 12 nm. Therefore, the SLD can be considered as a candidate to be used in the applications with high speed and low power consumption.

  11. The association between soluble intercellular adhesion molecule-1 levels in drained dialysate and peritoneal injury in peritoneal dialysis.

    Science.gov (United States)

    Igarashi, Yusuke; Morishita, Yoshiyuki; Yoshizawa, Hiromichi; Imai, Reika; Imai, Toshimi; Hirahara, Ichiro; Akimoto, Tetsu; Ookawara, Susumu; Ishibashi, Kenichi; Muto, Shigeaki; Nagata, Daisuke

    2017-11-01

    Chronic inflammation of the peritoneum causes peritoneal injury in patients on peritoneal dialysis. Intercellular adhesion molecule-1 and its circulating form, soluble intercellular adhesion molecule-1, play pivotal roles in inflammation. However, their role in peritoneal injury is unclear. We measured changes in intercellular adhesion molecule-1 expression in the peritoneum of a peritoneal injury model in rats. The associations between soluble intercellular adhesion molecule-1 levels in drained dialysate and the solute transport rate (D/P-Cr and D/D0-glucose) determined by the peritoneal equilibration test, and matrix metalloproteinase-2 levels in drained dialysate were investigated in 94 peritoneal drained dialysate samples. Intercellular adhesion molecule-1 expression was increased in the peritoneum of rats with peritoneal injury. Soluble intercellular adhesion molecule-1 levels in drained dialysate were significantly positively correlated with D/P-Cr (r = .51, p molecule-1expression is increased in the peritoneum of a peritoneal injury model in the rat, and soluble intercellular adhesion molecule-1 levels in drained dialysate are associated with peritoneal injury in patients on peritoneal dialysis. These results suggest that soluble intercellular adhesion molecule-1 could be a novel biomarker of peritoneal injury in patients on peritoneal dialysis.

  12. Percutaneous Retrieval of a Retained Jackson-Pratt Drain Fragment

    International Nuclear Information System (INIS)

    Namyslowski, Jan; Halin, Neil J.; Greenfield, Alan J.

    1996-01-01

    A retained intraabdominal Jackson-Pratt drain fragment was percutaneously retrieved using an inflated angioplasty balloon that had been maneuvered inside of the drain lumen over a hydrophilic-coated steerable guidewire

  13. Modeling and simulation of enhancement mode p-GaN Gate AlGaN/GaN HEMT for RF circuit switch applications

    Science.gov (United States)

    Panda, D. K.; Lenka, T. R.

    2017-06-01

    An enhancement mode p-GaN gate AlGaN/GaN HEMT is proposed and a physics based virtual source charge model with Landauer approach for electron transport has been developed using Verilog-A and simulated using Cadence Spectre, in order to predict device characteristics such as threshold voltage, drain current and gate capacitance. The drain current model incorporates important physical effects such as velocity saturation, short channel effects like DIBL (drain induced barrier lowering), channel length modulation (CLM), and mobility degradation due to self-heating. The predicted I d-V ds, I d-V gs, and C-V characteristics show an excellent agreement with the experimental data for both drain current and capacitance which validate the model. The developed model was then utilized to design and simulate a single-pole single-throw (SPST) RF switch.

  14. Laparoscopic elective cholecystectomy with and without drain: A controlled randomised trial

    Directory of Open Access Journals (Sweden)

    Gouda El-labban

    2012-01-01

    Full Text Available Background : Laparoscopic cholecystectomy is the main method of treatment of symptomatic gallstones. Routine drainage after laparoscopic cholecystectomy is an issue of considerable debate. Therefore, a controlled randomised trial was designed to assess the value of drains in elective laparoscopic cholecystectomy. Materials and Methods: During a two-year period (From April 2008 to January 2010, 80 patients were simply randomised to have a drain placed (group A, an 8-mm pentose tube drain was retained below the liver bed, whereas 80 patients were randomised not to have a drain (group B placed in the subhepatic space. End points of this trial were to detect any differences in morbidity, postoperative pain, wound infection and hospital stay between the two groups. Results : There was no mortality in either group and no statistically significant difference in postoperative pain, nausea and vomiting, wound infection or abdominal collection between the two groups. However, hospital stay was longer in the drain group than in group without drain and it is appearing that the use of drain delays hospital discharge. Conclusion : The routine use of a drain in non-complicated laparoscopic cholecystectomy has nothing to offer; in contrast, it is associated with longer hospital stay.

  15. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    OpenAIRE

    Gonzalo García-Ros; Iván Alhama; Manuel Cánovas

    2018-01-01

    The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018), a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD) and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulat...

  16. Iatrogenic Perforation of the Left Ventricle during Insertion of a Chest Drain

    OpenAIRE

    Kim, Dongmin; Lim, Seong-Hoon; Seo, Pil Won

    2013-01-01

    Chest draining is a common procedure for treating pleural effusion. Perforation of the heart is a rare often fatal complication of chest drain insertion. We report a case of a 76-year-old female patient suffering from congestive heart failure. At presentation, unilateral opacity of the left chest observed on a chest X-ray was interpreted as massive pleural effusion, so an attempt was made to drain the left pleural space. Malposition of the chest drain was suspected because blood was draining ...

  17. Current experience and a new modeling on water hammer due to steam condensation in PWR secondary system

    International Nuclear Information System (INIS)

    Kawanishi, K.; Kasahara, J.; Ueno, T.; Suzuta, T.

    1998-01-01

    There have been possibilities to occur water hammer in pipelines of turbine system for nuclear or fossil fuel power plants. According to the NUREG report, approximately 150 events have been reported since 1969, we also have an experience recently. Water hammer occurs due to sudden steam condensation with pressure pulse. This kind of pressure pulses has been made by alternative producing and condensing of steam slug in the pipe and its frequency relates subcooling and pipe structures. This paper presents our current experience on water hammer with some experimental studies. The present experiment has been performed to obtain the data base for evaluating the pressure pulses. The test pipe was horizontal tubes with dead end connected to vertical tube which simulating drain line in PWR secondary system. The main results are shown as follows; Magnitude of pressure pulse depends drain velocity and initial subcooling. Pipe structure effects on the frequency and continual time of water hammer phenomenon. A new modeling for quantitative explanation of the phenomena is also presented

  18. Horner's syndrome caused by an intercostal chest drain.

    OpenAIRE

    Campbell, P; Neil, T; Wake, P N

    1989-01-01

    Horner's syndrome occurred in a young woman as a complication of the treatment of a traumatic pneumothorax with an intercostal drain. The nerve damage probably occurred when the lung had fully re-expanded, pressing the tip of the intercostal drain, lying at the apex of the pleural cavity, on to the sympathetic chain.

  19. Rethinking "Brain Drain" in the Era of Globalisation

    Science.gov (United States)

    Rizvi, Fazal

    2005-01-01

    This paper discusses a range of issues concerning the idea of "brain drain" within the context of recent thinking on transnational mobility. It argues that the traditional analyses of brain drain are not sufficient, and that we can usefully approach the topic from a postcolonial perspective concerned with issues of identity, national…

  20. Comparison of a large and small-calibre tube drain for managing spontaneous pneumothoraces.

    Science.gov (United States)

    Benton, Ian J; Benfield, Grant F A

    2009-10-01

    To compare treatment success of large- and small-bore chest drains in the treatment of spontaneous pneumothoraces the case-notes were reviewed of those admitted to our hospital with a total of 73 pneumothoraces and who were treated by trainee doctors of varying experience. Both a large- and a small-bore intercostal tube drain system were in use during the two-year period reviewed. Similar pneumothorax profile and numbers treated with both drains were recorded, resulting in a similar drain time and numbers of successful and failed re-expansion of pneumothoraces. Successful pneumothorax resolution was the same for both drain types and the negligible tube drain complications observed with the small-bore drain reflected previously reported experiences. However the large-bore drain was associated with a high complication rate (32%) with more infectious complications (24%). The small-bore drain was prone to displacement (21%). There was generally no evidence of an increased failure and morbidity, reflecting poorer expertise, in the non-specialist trainees managing the pneumothoraces. A practical finding however was that in those large pneumothoraces where re-expansion failed, the tip of the drain had not been sited at the apex of the pleural cavity irrespective of the drain type inserted.

  1. A low on-resistance SOI LDMOS using a trench gate and a recessed drain

    International Nuclear Information System (INIS)

    Ge Rui; Luo Xiaorong; Jiang Yongheng; Zhou Kun; Wang Pei; Wang Qi; Wang Yuangang; Zhang Bo; Li Zhaoji

    2012-01-01

    An integrable silicon-on-insulator (SOI) power lateral MOSFET with a trench gate and a recessed drain (TGRD MOSFET) is proposed to reduce the on-resistance. Both of the trench gate extended to the buried oxide (BOX) and the recessed drain reduce the specific on-resistance (R on,sp ) by widening the vertical conduction area and shortening the extra current path. The trench gate is extended as a field plate improves the electric field distribution. Breakdown voltage (BV) of 97 V and R on,sp of 0.985 mΩ·cm 2 (V GS = 5 V) are obtained for a TGRD MOSFET with 6.5 μm half-cell pitch. Compared with the trench gate SOI MOSFET (TG MOSFET) and the conventional MOSFET, R on,sp of the TGRD MOSFET decreases by 46% and 83% at the same BV, respectively. Compared with the SOI MOSFET with a trench gate and a trench drain (TGTD MOSFET), BV of the TGRD MOSFET increases by 37% at the same R on,sp . (semiconductor devices)

  2. N loss to drain flow and N2O emissions from a corn-soybean rotation with winter rye.

    Science.gov (United States)

    Gillette, K; Malone, R W; Kaspar, T C; Ma, L; Parkin, T B; Jaynes, D B; Fang, Q X; Hatfield, J L; Feyereisen, G W; Kersebaum, K C

    2018-03-15

    Anthropogenic perturbation of the global nitrogen cycle and its effects on the environment such as hypoxia in coastal regions and increased N 2 O emissions is of increasing, multi-disciplinary, worldwide concern, and agricultural production is a major contributor. Only limited studies, however, have simultaneously investigated NO 3 - losses to subsurface drain flow and N 2 O emissions under corn-soybean production. We used the Root Zone Water Quality Model (RZWQM) to evaluate NO 3 - losses to drain flow and N 2 O emissions in a corn-soybean system with a winter rye cover crop (CC) in central Iowa over a nine year period. The observed and simulated average drain flow N concentration reductions from CC were 60% and 54% compared to the no cover crop system (NCC). Average annual April through October cumulative observed and simulated N 2 O emissions (2004-2010) were 6.7 and 6.0kgN 2 O-Nha -1 yr -1 for NCC, and 6.2 and 7.2kgNha -1 for CC. In contrast to previous research, monthly N 2 O emissions were generally greatest when N loss to leaching were greatest, mostly because relatively high rainfall occurred during the months fertilizer was applied. N 2 O emission factors of 0.032 and 0.041 were estimated for NCC and CC using the tested model, which are similar to field results in the region. A local sensitivity analysis suggests that lower soil field capacity affects RZWQM simulations, which includes increased drain flow nitrate concentrations, increased N mineralization, and reduced soil water content. The results suggest that 1) RZWQM is a promising tool to estimate N 2 O emissions from subsurface drained corn-soybean rotations and to estimate the relative effects of a winter rye cover crop over a nine year period on nitrate loss to drain flow and 2) soil field capacity is an important parameter to model N mineralization and N loss to drain flow. Published by Elsevier B.V.

  3. FROM BRAIN DRAIN TO BRAIN NETWORKING

    Directory of Open Access Journals (Sweden)

    Irina BONCEA

    2015-06-01

    Full Text Available Scientific networking is the most accessible way a country can turn the brain drain into brain gain. Diaspora’s members offer valuable information, advice or financial support from the destination country, without being necessary to return. This article aims to investigate Romania’s potential of turning brain drain into brain networking, using evidence from the medical sector. The main factors influencing the collaboration with the country of origin are investigated. The conclusions suggest that Romania could benefit from the diaspora option, through an active implication at institutional level and the implementation of a strategy in this area.

  4. Method of draining water through a solid waste site without leaching

    Science.gov (United States)

    Treat, Russell L.; Gee, Glendon W.; Whyatt, Greg A.

    1993-01-01

    The present invention is a method of preventing water from leaching solid waste sites by preventing atmospheric precipitation from contacting waste as the water flows through a solid waste site. The method comprises placing at least one drain hole through the solid waste site. The drain hole is seated to prevent waste material from entering the drain hole, and the solid waste site cover material is layered and graded to direct water to flow toward the drain hole and to soil beneath the waste site.

  5. Vertical organic field effect phototransistor with two dissimilar source and drain contacts

    International Nuclear Information System (INIS)

    Woon, K.L.; Yeo, G.N.

    2014-01-01

    A solution processable vertical organic field effect phototransistor was fabricated using poly(3-hexylthiophene) and 1-(3-methoxycarbonyl)propyl-1-phenyl[6,6]C61 as the photo-active materials while poly(methyl methacrylate) is used as a dielectric layer. Interdigitated conductive poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) is used as a source and lithium flouride/aluminum as a drain. The device exhibits current modulation when the gate is positively biased. A significant photoeffect is observed in the reverse bias mode. Unlike conventional organic phototransistors, this device can operate at a zero source–drain bias with a photosensitivity and responsivity proportional to the gate voltage. A photosensitivity of up to 10 5 and a responsivity of up to 2 AW −1 are achieved in this mode. This effect is due to the presence of the weak photovoltaic behavior of this device. - Highlights: • A solution processable vertical field effect phototransistor is demonstrated. • Photosensitivity as high as ∼ 10 5 with responsivity of 2 AW −1 is achieved. • The gate can be used to modulate photocurrent with low leakage current. • The device shows weak photovoltaic behavior

  6. Temperature dependence of the current in Schottky-barrier source-gated transistors

    Science.gov (United States)

    Sporea, R. A.; Overy, M.; Shannon, J. M.; Silva, S. R. P.

    2015-05-01

    The temperature dependence of the drain current is an important parameter in thin-film transistors. In this paper, we propose that in source-gated transistors (SGTs), this temperature dependence can be controlled and tuned by varying the length of the source electrode. SGTs comprise a reverse biased potential barrier at the source which controls the current. As a result, a large activation energy for the drain current may be present which, although useful in specific temperature sensing applications, is in general deleterious in many circuit functions. With support from numerical simulations with Silvaco Atlas, we describe how increasing the length of the source electrode can be used to reduce the activation energy of SGT drain current, while maintaining the defining characteristics of SGTs: low saturation voltage, high output impedance in saturation, and tolerance to geometry variations. In this study, we apply the dual current injection modes to obtain drain currents with high and low activation energies and propose mechanisms for their exploitation in future large-area integrated circuit designs.

  7. Two-dimensional analytical model for dual-material control-gate tunnel FETs

    Science.gov (United States)

    Xu, Hui Fang; Dai, Yue Hua; Gui Guan, Bang; Zhang, Yong Feng

    2016-09-01

    An analytical model for a dual-material control-gate (DMCG) tunnel field effect transistor (TFET) is presented for the first time in this paper, and the influence of the mobile charges on the potential profile is taken into account. On the basis of the potential profile, the lateral electric field is derived and the expression for the drain current is obtained by integrating the band-to-band tunneling (BTBT) generation rate applicable to low-bandgap and high-bandgap materials over the tunneling region. The model also predicts the impacts of the control-gate work function on the potential and drain current. The advantage of this work is that it not only offers physical insight into device physics but also provides the basic designing guideline for DMCG TFETs, enabling the designer to optimize the device in terms of the on-state current, the on-off current ratio, and suppressed ambipolar behavior. Very good agreements for both the potential and drain current are observed between the model calculations and the simulated results.

  8. Land use of drained peatlands: Greenhouse gas fluxes, plant production, and economics.

    Science.gov (United States)

    Kasimir, Åsa; He, Hongxing; Coria, Jessica; Nordén, Anna

    2017-10-10

    Drained peatlands are hotspots for greenhouse gas (GHG) emissions, which could be mitigated by rewetting and land use change. We performed an ecological/economic analysis of rewetting drained fertile peatlands in a hemiboreal climate using different land use strategies over 80 years. Vegetation, soil processes, and total GHG emissions were modeled using the CoupModel for four scenarios: (1) business as usual-Norway spruce with average soil water table of -40 cm; (2) willow with groundwater at -20 cm; (3) reed canary grass with groundwater at -10 cm; and (4) a fully rewetted peatland. The predictions were based on previous model calibrations with several high-resolution datasets consisting of water, heat, carbon, and nitrogen cycling. Spruce growth was calibrated by tree-ring data that extended the time period covered. The GHG balance of four scenarios, including vegetation and soil, were 4.7, 7.1, 9.1, and 6.2 Mg CO 2 eq ha -1  year -1 , respectively. The total soil emissions (including litter and peat respiration CO 2 + N 2 O + CH 4 ) were 33.1, 19.3, 15.3, and 11.0 Mg CO 2 eq ha -1  year -1 , respectively, of which the peat loss contributed 35%, 24%, and 7% of the soil emissions for the three drained scenarios, respectively. No peat was lost for the wet peatland. It was also found that draining increases vegetation growth, but not as drastically as peat respiration does. The cost-benefit analysis (CBA) is sensitive to time frame, discount rate, and carbon price. Our results indicate that the net benefit was greater with a somewhat higher soil water table and when the peatland was vegetated with willow and reed canary grass (Scenarios 2 and 3). We conclude that saving peat and avoiding methane release using fairly wet conditions can significantly reduce GHG emissions, and that this strategy should be considered for land use planning and policy-making. © 2017 John Wiley & Sons Ltd.

  9. Inverse problem in anisotropic poroelasticity: drained constants from undrained ultrasound measurements.

    Science.gov (United States)

    Berryman, James G; Nakagawa, Seiji

    2010-02-01

    Poroelastic analysis has traditionally focused on the relationship between dry and drained constants, which are assumed known, and the saturated or undrained constants, which are assumed unknown. However, there are many applications in this field of study for which the main measurements can only be made on the saturated/undrained system, and then it is uncertain what the effects of the fluids were on the system, since the drained constants remain a mystery. The work presented here shows how to deduce drained constants from undrained constants for anisotropic systems having symmetries ranging from isotropic to orthotropic. Laboratory ultrasound data are then inverted for the drained constants in three granular packings: one of glass beads, and two others for distinct types of more or less angular sand grain packings. Experiments were performed under uniaxial stress, which resulted in hexagonal (transversely isotropic) symmetry of the poroelastic response. One important conclusion from the general analysis is that the drained constants are uniquely related to the undrained constants, assuming that porosity, grain bulk modulus, and pore fluid bulk modulus are already known. Since the resulting system of equations for all the drained constants is linear, measurement error in undrained constants also propagates linearly into the computed drained constants.

  10. Inverse problem in anisotropic poroelasticity: Drained constants from undrained ultrasound measurements

    Energy Technology Data Exchange (ETDEWEB)

    Berryman, J.G.; Nakagawa, S.

    2009-11-20

    Poroelastic analysis has traditionally focused on the relationship between dry or drained constants which are assumed known and the saturated or undrained constants which are assumed unknown. However, there are many applications in this field of study for which the main measurements can only be made on the saturated/undrained system, and then it is uncertain what the eects of the uids were on the system, since the drained constants remain a mystery. The work presented here shows how to deduce drained constants from undrained constants for anisotropic systems having symmetries ranging from isotropic to orthotropic. Laboratory ultrasound data are then inverted for the drained constants in three granular packings: one of glass beads, and two others for distinct types of more or less angular sand grain packings. Experiments were performed under uniaxial stress, which resulted in hexagonal (transversely isotropic) symmetry of the poroelastic response. One important conclusion from the general analysis is that the drained constants are uniquely related to the undrained constants, assuming that porosity, grain bulk modulus, and pore uid bulk modulus are already known. Since the resulting system of equations for all the drained constants is linear, measurement error in undrained constants also propagates linearly into the computed drained constants.

  11. Detecting peatland drains with Object Based Image Analysis and Geoeye-1 imagery.

    Science.gov (United States)

    Connolly, J; Holden, N M

    2017-12-01

    Peatlands play an important role in the global carbon cycle. They provide important ecosystem services including carbon sequestration and storage. Drainage disturbs peatland ecosystem services. Mapping drains is difficult and expensive and their spatial extent is, in many cases, unknown. An object based image analysis (OBIA) was performed on a very high resolution satellite image (Geoeye-1) to extract information about drain location and extent on a blanket peatland in Ireland. Two accuracy assessment methods: Error matrix and the completeness, correctness and quality (CCQ) were used to assess the extracted data across the peatland and at several sub sites. The cost of the OBIA method was compared with manual digitisation and field survey. The drain maps were also used to assess the costs relating to blocking drains vs. a business-as-usual scenario and estimating the impact of each on carbon fluxes at the study site. The OBIA method performed well at almost all sites. Almost 500 km of drains were detected within the peatland. In the error matrix method, overall accuracy (OA) of detecting the drains was 94% and the kappa statistic was 0.66. The OA for all sub-areas, except one, was 95-97%. The CCQ was 85%, 85% and 71% respectively. The OBIA method was the most cost effective way to map peatland drains and was at least 55% cheaper than either field survey or manual digitisation, respectively. The extracted drain maps were used constrain the study area CO 2 flux which was 19% smaller than the prescribed Peatland Code value for drained peatlands. The OBIA method used in this study showed that it is possible to accurately extract maps of fine scale peatland drains over large areas in a cost effective manner. The development of methods to map the spatial extent of drains is important as they play a critical role in peatland carbon dynamics. The objective of this study was to extract data on the spatial extent of drains on a blanket bog in the west of Ireland. The

  12. Detecting peatland drains with Object Based Image Analysis and Geoeye-1 imagery

    Directory of Open Access Journals (Sweden)

    J. Connolly

    2017-03-01

    Full Text Available Abstract Background Peatlands play an important role in the global carbon cycle. They provide important ecosystem services including carbon sequestration and storage. Drainage disturbs peatland ecosystem services. Mapping drains is difficult and expensive and their spatial extent is, in many cases, unknown. An object based image analysis (OBIA was performed on a very high resolution satellite image (Geoeye-1 to extract information about drain location and extent on a blanket peatland in Ireland. Two accuracy assessment methods: Error matrix and the completeness, correctness and quality (CCQ were used to assess the extracted data across the peatland and at several sub sites. The cost of the OBIA method was compared with manual digitisation and field survey. The drain maps were also used to assess the costs relating to blocking drains vs. a business-as-usual scenario and estimating the impact of each on carbon fluxes at the study site. Results The OBIA method performed well at almost all sites. Almost 500 km of drains were detected within the peatland. In the error matrix method, overall accuracy (OA of detecting the drains was 94% and the kappa statistic was 0.66. The OA for all sub-areas, except one, was 95–97%. The CCQ was 85%, 85% and 71% respectively. The OBIA method was the most cost effective way to map peatland drains and was at least 55% cheaper than either field survey or manual digitisation, respectively. The extracted drain maps were used constrain the study area CO2 flux which was 19% smaller than the prescribed Peatland Code value for drained peatlands. Conclusions The OBIA method used in this study showed that it is possible to accurately extract maps of fine scale peatland drains over large areas in a cost effective manner. The development of methods to map the spatial extent of drains is important as they play a critical role in peatland carbon dynamics. The objective of this study was to extract data on the spatial extent of

  13. Top-gated chemical vapor deposition grown graphene transistors with current saturation.

    Science.gov (United States)

    Bai, Jingwei; Liao, Lei; Zhou, Hailong; Cheng, Rui; Liu, Lixin; Huang, Yu; Duan, Xiangfeng

    2011-06-08

    Graphene transistors are of considerable interest for radio frequency (rf) applications. In general, transistors with large transconductance and drain current saturation are desirable for rf performance, which is however nontrivial to achieve in graphene transistors. Here we report high-performance top-gated graphene transistors based on chemical vapor deposition (CVD) grown graphene with large transconductance and drain current saturation. The graphene transistors were fabricated with evaporated high dielectric constant material (HfO(2)) as the top-gate dielectrics. Length scaling studies of the transistors with channel length from 5.6 μm to 100 nm show that complete current saturation can be achieved in 5.6 μm devices and the saturation characteristics degrade as the channel length shrinks down to the 100-300 nm regime. The drain current saturation was primarily attributed to drain bias induced shift of the Dirac points. With the selective deposition of HfO(2) gate dielectrics, we have further demonstrated a simple scheme to realize a 300 nm channel length graphene transistors with self-aligned source-drain electrodes to achieve the highest transconductance of 250 μS/μm reported in CVD graphene to date.

  14. DETERMINATION OF LIQUID FILM THICKNESS FOLLOWING DRAINING OF CONTACTORS, VESSELS, AND PIPES IN THE MCU PROCESS

    International Nuclear Information System (INIS)

    Poirier, M; Fernando Fondeur, F; Samuel Fink, S

    2006-01-01

    The Department of Energy (DOE) identified the caustic side solvent extraction (CSSX) process as the preferred technology to remove cesium from radioactive waste solutions at the Savannah River Site (SRS). As a result, Washington Savannah River Company (WSRC) began designing and building a Modular CSSX Unit (MCU) in the SRS tank farm to process liquid waste for an interim period until the Salt Waste Processing Facility (SWPF) begins operations. Both the solvent and the strip effluent streams could contain high concentrations of cesium which must be removed from the contactors, process tanks, and piping prior to performing contactor maintenance. When these vessels are drained, thin films or drops will remain on the equipment walls. Following draining, the vessels will be flushed with water and drained to remove the flush water. The draining reduces the cesium concentration in the vessels by reducing the volume of cesium-containing material. The flushing, and subsequent draining, reduces the cesium in the vessels by diluting the cesium that remains in the film or drops on the vessel walls. MCU personnel requested that Savannah River National Laboratory (SRNL) researchers conduct a literature search to identify models to calculate the thickness of the liquid films remaining in the contactors, process tanks, and piping following draining of salt solution, solvent, and strip solution. The conclusions from this work are: (1) The predicted film thickness of the strip effluent is 0.010 mm on vertical walls, 0.57 mm on horizontal walls and 0.081 mm in horizontal pipes. (2) The predicted film thickness of the salt solution is 0.015 mm on vertical walls, 0.74 mm on horizontal walls, and 0.106 mm in horizontal pipes. (3) The predicted film thickness of the solvent is 0.022 mm on vertical walls, 0.91 mm on horizontal walls, and 0.13 mm in horizontal pipes. (4) The calculated film volume following draining is: (a) Salt solution receipt tank--1.6 gallons; (b) Salt solution feed

  15. Nurses’ Knowledge Levels of Chest Drain Management: A Descriptive Study

    Directory of Open Access Journals (Sweden)

    Merve Tarhan

    2016-12-01

    Full Text Available Objective: The physician is responsible for inserting one or more chest tubes into the pleural space or the mediastinal space and connecting them to an appropriate drainage system. When the general principles about care of patients with chest drains were implemented correctly and effectively by nurses, nurse will contribute to accelerate the healing process of patients. In this context, the aim of this study was to determine the nurses’ level of knowledge regarding the care of patients with chest drains. Methods: The study was conducted with 153 nurses who worked in a chest diseases and thoracic surgery hospital in July 2014. Questionnaire form of 35 questions prepared by investigators was used to collect data. For the analysis of results, frequency tests, independent sample t-test and oneway ANOVA test were used. Results: 69.3% of nurses stated that they had obtained information from colleguages. 35.3% considered their knowledge about chest drain management to be inadequate. 55.6% scored 13 points and above from knowledge questionnaire about chest drain management. There were statistically significant difference between knowledge level and educational background, clinic work type, working unit, years of professional experience and institutional experience, frequency of contact patients with chest drain and perception of knowledge level (p<0.05. Conclusion: Results of this study indicate that lack of evidence-based nursing care and insufficient training has resulted in uncertainty and knowledge deficit in important aspects of chest drain care. It can be concluded that nurses receive training needs and training protocols are about chest drain management.

  16. MEDICAL BRAIN DRAIN - A THEORETICAL APPROACH

    Directory of Open Access Journals (Sweden)

    Boncea Irina

    2013-07-01

    Full Text Available Medical brain drain is defined as the migration of health personnel from developing countries to developed countries and between industrialized nations in search for better opportunities. This phenomenon became a global growing concern due to its impact on both the donor and the destination countries. This article aims to present the main theoretical contributions starting from 1950 until today and the historical evolution, in the attempt of correlating the particular case of medical brain drain with the theory and evolution of the brain drain in general. This article raises questions and offers answers, identifies the main issues and looks for possible solutions in order to reduce the emigration of medical doctors. Factors of influence include push (low level of income, poor working conditions, the absence of job openings and social recognition, oppressive political climate and pull (better remuneration and working conditions, prospects for career development, job satisfaction, security factors. Developing countries are confronting with the loss of their most valuable intellectuals and the investment in their education, at the benefit of developed nations. An ethical debate arises as the disparities between countries increases, industrialized nations filling in the gaps in health systems with professionals from countries already facing shortages. However, recent literature emphasizes the possibility of a “beneficial brain drain” through education incentives offered by the emigration prospects. Other sources of “brain gain” for donor country are the remittances, the scientific networks and return migration. Measures to stem the medical brain drain involve the common effort and collaboration between developing and developed countries and international organizations. Measures adopted by donor countries include higher salaries, better working conditions, security, career opportunities, incentives to stimulate return migration. Destination

  17. Perspective analysis of tri gate germanium tunneling field-effect transistor with dopant segregation region at source/drain

    Science.gov (United States)

    Liu, Liang-kui; Shi, Cheng; Zhang, Yi-bo; Sun, Lei

    2017-04-01

    A tri gate Ge-based tunneling field-effect transistor (TFET) has been numerically studied with technology computer aided design (TCAD) tools. Dopant segregated Schottky source/drain is applied to the device structure design (DS-TFET). The characteristics of the DS-TFET are compared and analyzed comprehensively. It is found that the performance of n-channel tri gate DS-TFET with a positive bias is insensitive to the dopant concentration and barrier height at n-type drain, and that the dopant concentration and barrier height at a p-type source considerably affect the device performance. The domination of electron current in the entire BTBT current of this device accounts for this phenomenon and the tri-gate DS-TFET is proved to have a higher performance than its dual-gate counterpart.

  18. An analysis of molten-corium-induced failure of drain pipes in BWR Mark 2 containments

    International Nuclear Information System (INIS)

    Taleyarkhan, R.P.; Podowski, M.Z.

    1991-01-01

    This study has focused on mechanistic simulation and analysis of potential failure modes for inpedestal drywell drain pipes in the Limerick boiling water reactor (BWR) Mark 2 containment. Physical phenomena related to surface tension breakdown, heatup, melting, ablation, crust formation and failure, and core material relocation into drain pipes with simultaneous melting of pipe walls were modeled and analyzed. The results of analysis have been used to assess the possibility of drain pipe failure and the resultant loss of pressure-suppression capability. Estimates have been made for the timing and amount of molten corium released to the wetwell. The study has revealed that significantly different melt progression sequences can result depending upon the failure characteristics of the frozen metallic crust which forms over the drain cover during the initial stages of debris pour. Another important result is that it can take several days for the molten fuel to ablate the frozen metallic debris layer -- if the frozen layer has cooled below 1100 K before fuel attack. 10 refs., 3 figs., 4 tabs

  19. Brain drain: Propulsive factors and consequences

    Directory of Open Access Journals (Sweden)

    Dragan ILIC

    2018-01-01

    Full Text Available When speaking about the total number of highly educated individuals’ migration, it is easy to spot that it is rapidly increasing. The brain drain issues should be taken very seriously especially in under developed and in the developing countries, knowing that the human capital is globally mobile and that highly educated individuals can without any issues market their knowledge around the globe. Dealing with it requires a carefully tailored strategy for these countries, which are suffering from severe human capital losses on annual basis. Since the labor markets of today are highly competitive, it is necessary for these countries to secure good advancement and doing business opportunities. The purpose of this research is to provide an insight into the key propulsive factors and potential consequences caused by the brain drain. The method used in order to conduct the research was a carefully designed questionnaire taken by the date subject enrolled at the third and fourth years of state governed and privately owned universities. This research shows that one of the key reasons for brain drain in underdeveloped and in the developing countries is shortage of further educational advancement opportunities.

  20. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.

    Science.gov (United States)

    Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho

    2011-05-01

    A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  1. Potential depletion of surface water in the Colorado River and agricultural drains by groundwater pumping in the Parker-Palo Verde-Cibola area, Arizona and California

    Science.gov (United States)

    Leake, Stanley A.; Owen-Joyce, Sandra J.; Heilman, Julian A.

    2013-01-01

    Water use along the lower Colorado River is allocated as “consumptive use,” which is defined to be the amount of water diverted from the river minus the amount that returns to the river. Diversions of water from the river include surface water in canals and water removed from the river by pumping wells in the aquifer connected to the river. A complication in accounting for water pumped by wells occurs if the pumping depletes water in drains and reduces measured return flow in those drains. In that case, consumptive use of water pumped by the wells is accounted for in the reduction of measured return flow. A method is needed to understand where groundwater pumping will deplete water in the river and where it will deplete water in drains. To provide a basis for future accounting for pumped groundwater in the Parker-Palo Verde-Cibola area, a superposition model was constructed. The model consists of three layers of finite-difference cells that cover most of the aquifer in the study area. The model was run repeatedly with each run having a pumping well in a different model cell. The source of pumped water that is depletion of the river, expressed as a fraction of the pumping rate, was computed for all active cells in model layer 1, and maps were constructed to understand where groundwater pumping depletes the river and where it depletes drains. The model results indicate that if one or more drains exist between a pumping well location and the river, nearly all of the depletion will be from drains, and little or no depletion will come from the Colorado River. Results also show that if a well pumps on a side of the river with no drains in the immediate area, depletion will come from the Colorado River. Finally, if a well pumps between the river and drains that parallel the river, a fraction of the pumping will come from the river and the rest will come from the drains. Model results presented in this report may be considered in development or refinement of strategies

  2. Effect of drains on the seepage of contaminants from subgrade tailings disposal areas

    International Nuclear Information System (INIS)

    Witten, A.J.; Pin, F.G.; Sharp, R.D.

    1984-01-01

    A numerical simulation study is performed to investigate the influence of ponded water and a bottom drain on the pathways for contaminant migration from a subgrade uranium mill tailings disposal pit. A numerical model is applied to a generic disposal pit constructed with a bottom clay liner and steep unlined sidewalls. The migration of a two-contaminant system is modeled assuming that neither contaminant decays and only one contaminant is retarded. Two dominant pathways are identified; one associated with lateral sidewall leakage and the other associated with transport through the bottom clay liner. It is found that the drain serves to reduce migration through the sidewall which, in turn, prevents the retarded contaminant from reaching the aquifer. The ponded water provides increased head which causes an accelerated vertical movement of moisture through the clay liner. 2 references, 8 figures

  3. Steam generator fitted with a dynamic draining device

    International Nuclear Information System (INIS)

    Chaix, J.E.

    1982-01-01

    This generator has, at its upper part, at least one drying structure for holding the water carried with the steam and communicating at its lower part with at least one discharge pipe for draining off the water, each pipe communicating with a dynamic draining device capable of creating a depression in order to suck up the water contained in the drying structure. Application is for pressurized water nuclear reactors [fr

  4. Leaching of dissolved phosphorus from tile-drained agricultural areas.

    Science.gov (United States)

    Andersen, H E; Windolf, J; Kronvang, B

    2016-01-01

    We investigated leaching of dissolved phosphorus (P) from 45 tile-drains representing animal husbandry farms in all regions of Denmark. Leaching of P via tile-drains exhibits a high degree of spatial heterogeneity with a low concentration in the majority of tile-drains and few tile-drains (15% in our investigation) having high to very high concentration of dissolved P. The share of dissolved organic P (DOP) was high (up to 96%). Leaching of DOP has hitherto been a somewhat overlooked P loss pathway in Danish soils and the mechanisms of mobilization and transport of DOP needs more investigation. We found a high correlation between Olsen-P and water extractable P. Water extractable P is regarded as an indicator of risk of loss of dissolved P. Our findings indicate that Olsen-P, which is measured routinely in Danish agricultural soils, may be a useful proxy for the P leaching potential of soils. However, we found no straight-forward correlation between leaching potential of the top soil layer (expressed as either degree of P saturation, Olsen-P or water extractable P) and the measured concentration of dissolved P in the tile-drain. This underlines that not only the source of P but also the P loss pathway must be taken into account when evaluating the risk of P loss.

  5. Numerical Simulation of Liquids Draining From a Tank Using OpenFOAM

    Science.gov (United States)

    Sakri, Fadhilah Mohd; Sukri Mat Ali, Mohamed; Zaki Shaikh Salim, Sheikh Ahmad; Muhamad, Sallehuddin

    2017-08-01

    Accurate simulation of liquids draining is a challenging task. It involves two phases flow, i.e. liquid and air. In this study draining a liquid from a cylindrical tank is numerically simulated using OpenFOAM. OpenFOAM is an open source CFD package and it becomes increasingly popular among the academician and also industries. Comparisons with theoretical and results from previous published data confirmed that OpenFOAM is able to simulate the liquids draining very well. This is done using the gas-liquid interface solver available in the standard library of OpenFOAM. Additionally, this study was also able to explain the physics flow of the draining tank.

  6. Closed suction drain with bulb

    Science.gov (United States)

    ... of gloves. Put a new bandage around the drain tube site. Use surgical tape to hold it down ... small amount of redness is normal). There is drainage from the skin around the tube site. There is more tenderness and swelling at ...

  7. Brain drain and health workforce distortions in Mozambique.

    Science.gov (United States)

    Sherr, Kenneth; Mussa, Antonio; Chilundo, Baltazar; Gimbel, Sarah; Pfeiffer, James; Hagopian, Amy; Gloyd, Stephen

    2012-01-01

    Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs), and the private sector. An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties. Of 723 qualifying physicians between 1980-2006, 95.9% (693) were working full-time, including 71.1% (493) as clinicians, 20.5% (142) as health system managers, and 6.9% (48) as researchers/professors. 25.5% (181) of the sample had left the public sector, of which 62.4% (113) continued working in-country and 37.6% (68) emigrated from Mozambique. Of those cases of internal migration, 66.4% (75) worked for NGOs, 21.2% (24) for donor agencies, and 12.4% (14) in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113) of internal migration cases had previously held senior-level management positions in the public sector. Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they seek

  8. Brain drain and health workforce distortions in Mozambique.

    Directory of Open Access Journals (Sweden)

    Kenneth Sherr

    Full Text Available Trained human resources are fundamental for well-functioning health systems, and the lack of health workers undermines public sector capacity to meet population health needs. While external brain drain from low and middle-income countries is well described, there is little understanding of the degree of internal brain drain, and how increases in health sector funding through global health initiatives may contribute to the outflow of health workers from the public sector to donor agencies, non-governmental organisations (NGOs, and the private sector.An observational study was conducted to estimate the degree of internal and external brain drain among Mozambican nationals qualifying from domestic and foreign medical schools between 1980-2006. Data were collected 26-months apart in 2008 and 2010, and included current employment status, employer, geographic location of employment, and main work duties.Of 723 qualifying physicians between 1980-2006, 95.9% (693 were working full-time, including 71.1% (493 as clinicians, 20.5% (142 as health system managers, and 6.9% (48 as researchers/professors. 25.5% (181 of the sample had left the public sector, of which 62.4% (113 continued working in-country and 37.6% (68 emigrated from Mozambique. Of those cases of internal migration, 66.4% (75 worked for NGOs, 21.2% (24 for donor agencies, and 12.4% (14 in the private sector. Annual incidence of physician migration was estimated to be 3.7%, predominately to work in the growing NGO sector. An estimated 36.3% (41/113 of internal migration cases had previously held senior-level management positions in the public sector.Internal migration is an important contributor to capital flight from the public sector, accounting for more cases of physician loss than external migration in Mozambique. Given the urgent need to strengthen public sector health systems, frank reflection by donors and NGOs is needed to assess how hiring practices may undermine the very systems they

  9. Analytical models for the 2DEG concentration and gate leakage current in AlGaN/GaN HEMTs

    Science.gov (United States)

    Ahmed, Nadim; Dutta, Aloke K.

    2017-06-01

    In this paper, we present a completely analytical model for the 2DEG concentration in AlGaN/GaN HEMTs as a function of gate bias, considering the donor-like trap states present at the metal/AlGaN interface to be the primary source of 2DEG carriers. To the best of our knowledge, this is a completely new contribution of this work. The electric field in the AlGaN layer is calculated using this model, which is further used to model the gate leakage current under reverse bias. We have modified the existing TTT (Thermionic Trap-Assisted Tunneling) current model, taking into account the effect of both metal/AlGaN interface traps as well as AlGaN bulk traps. The gate current under forward bias is also modeled using the existing thermionic emission model, approximating it by its Taylor series expansion. To take into account the effect of non-zero drain-source bias (VDS), an empirical fitting parameter is introduced in order to model the channel voltage in terms of VDS. The results of our models have been compared with the experimental data reported in the literature for three different devices, and the match is found to be excellent for both forward and reverse bias as well as for zero and non-zero VDS.

  10. Investigation of abrupt degradation of drain current caused by under-gate crack in AlGaN/GaN high electron mobility transistors during high temperature operation stress

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Chang; Liao, XueYang; Li, RuGuan; Wang, YuanSheng; Chen, Yiqiang, E-mail: yiqiang-chen@hotmail.com; Su, Wei; Liu, Yuan; Wang, Li Wei; Lai, Ping; Huang, Yun; En, YunFei [Science and Technology on Reliability Physics and Application of Electronic Component Laboratory, The 5th Electronics Research Institute of the Ministry of Industry and Information Technology, 510610 Guangzhou (China)

    2015-09-28

    In this paper, we investigate the degradation mode and mechanism of AlGaN/GaN based high electron mobility transistors (HEMTs) during high temperature operation (HTO) stress. It demonstrates that there was abrupt degradation mode of drain current during HTO stress. The abrupt degradation is ascribed to the formation of crack under the gate which was the result of the brittle fracture of epilayer based on failure analysis. The origin of the mechanical damage under the gate is further investigated and discussed based on top-down scanning electron microscope, cross section transmission electron microscope and energy dispersive x-ray spectroscopy analysis, and stress simulation. Based on the coupled analysis of the failure physical feature and stress simulation considering the coefficient of thermal expansion (CTE) mismatch in different materials in gate metals/semiconductor system, the mechanical damage under the gate is related to mechanical stress induced by CTE mismatch in Au/Ti/Mo/GaN system and stress concentration caused by the localized structural damage at the drain side of the gate edge. These results indicate that mechanical stress induced by CTE mismatch of materials inside the device plays great important role on the reliability of AlGaN/GaN HEMTs during HTO stress.

  11. Improving Current Balance In Parallel MOSFET's

    Science.gov (United States)

    Niedra, Janis M.

    1992-01-01

    Simple circuit makes currents more nearly equal. Addition of diodes and adjustable-tap resistor increases operating range over which drain currents in two unmatched power MOSFET's brought more nearly into balance.

  12. The effect of drains on the seepage of contaminants from subgrade tailings disposal areas

    International Nuclear Information System (INIS)

    Witten, A.J.; Pin, F.G.; Sharp, R.D.

    1984-01-01

    A numerical simulation study is performed to investigate the influence of ponded water and a bottom drain on the pathways for contaminant migration from a subgrade uranium mill tailings disposal pit. A numerical model is applied to a generic disposal pit constructed with a bottom clay liner and steep unlined sidewalls. The migration of a two-contaminant system is modeled assuming that neither contaminant decays and only one contaminant is retarded. Two dominant pathways are indentified; one associated with lateral sidewall leakage and the other associated with transport through the bottom clay liner. It is found that the drain serves to reduce migration through the sidewall which, in turn, prevents the retarded contaminant from reaching the aquifer. The ponded water provides increased head which causes an accelarated vertical movement of moisture through the clay liner

  13. Current-mode minimax circuit

    NARCIS (Netherlands)

    Wassenaar, R.F.

    1992-01-01

    The minimum-maximum (minimax) circuit selects the minimum and maximum of two input currents. Four transistors in matched pairs are operated in the saturation region. Because the behavior of the circuit is based on matched devices and is independent of the relationship between the drain current and

  14. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Grigoriev, Sergey; Lyublin, Boris; Maquet, Philippe; Senik, Konstantin; Pak, Sunil; Udintsev, Victor

    2016-01-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  15. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Tanchuk, Victor, E-mail: Victor.Tanchuk@sintez.niiefa.spb.su [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Grigoriev, Sergey; Lyublin, Boris [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Senik, Konstantin [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Pak, Sunil [National Fusion Research Institute, Daejeon (Korea, Republic of); Udintsev, Victor [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France)

    2016-11-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  16. The Simple Urine Bag as Wound Drain Post-Craniotomy in a Low ...

    African Journals Online (AJOL)

    Methods: A 4-year prospective cohort study of the effectiveness, outcome with use and complications of the Uribag as post craniotomy wound drain in a consecutive cohort of neurosurgical patients. Data analyzed include the patients' brief demographics; the types of cranial surgery in which drain was used; the drain ...

  17. Frequency dependence and passive drains in fish-eye lenses

    Science.gov (United States)

    Quevedo-Teruel, O.; Mitchell-Thomas, R. C.; Hao, Y.

    2012-11-01

    The Maxwell fish eye lens has previously been reported as being capable of the much sought after phenomenon of subwavelength imaging. The inclusion of a drain in this system is considered crucial to the imaging ability, although its role is the topic of much debate. This paper provides a numerical investigation into a practical implementation of a drain in such systems, and analyzes the strong frequency dependence of both the Maxwell fish eye lens and an alternative, the Miñano lens. The imaging capability of these types of lens is questioned, and it is supported by simulations involving various configurations of drain arrays. Finally, a discussion of the near-field and evanescent wave contribution is given.

  18. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  19. Improving band-to-band tunneling in a tunneling carbon nanotube field effect transistor by multi-level development of impurities in the drain region

    Science.gov (United States)

    Naderi, Ali; Ghodrati, Maryam

    2017-12-01

    In this paper, in order to improve the performance of a tunneling carbon nanotube field effect transistor (T-CNTFET) a new structure is proposed using multi-level impurity distribution along the drain region. The new T-CNTFET structure consists of six parts in the drain with stepwise doping distribution. The impurities on the drain side are n -type and the length of each region is 5nm. Electronic features of the proposed structure are simulated by the solution of Poisson and Schrödinger equations and the self-consistent method using Non-equilibrium Green's Function (NEGF). Simulation results show that the proposed structure reduces the band curvature near the drain-channel connection and widens the tunneling barrier. As a result, band-to-band tunneling and the OFF current are reduced and the ON/OFF current ratio increases in comparison with the conventional structure. In summary, by improving the subthreshold swing parameters, delay time, power delay product ( PDP and cut-off frequency compared to the conventional structure, the proposed structure can be considered as a proper candidate for digital applications with high speed and low power dissipation.

  20. A Unified Channel Charges Expression for Analytic MOSFET Modeling

    Directory of Open Access Journals (Sweden)

    Hugues Murray

    2012-01-01

    Full Text Available Based on a 1D Poissons equation resolution, we present an analytic model of inversion charges allowing calculation of the drain current and transconductance in the Metal Oxide Semiconductor Field Effect Transistor. The drain current and transconductance are described by analytical functions including mobility corrections and short channel effects (CLM, DIBL. The comparison with the Pao-Sah integral shows excellent accuracy of the model in all inversion modes from strong to weak inversion in submicronics MOSFET. All calculations are encoded with a simple C program and give instantaneous results that provide an efficient tool for microelectronics users.

  1. Drain Back Systems in Laboratory and in Practice

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2015-01-01

    in the collector loop to have a safe reliable operation. The components should also be designed and marked so that only one correct mounting option is possible, like forward and return pipes to/from the collector of slightly different sizes or color. Adapted installer education and training is a very important...... step to have success with drain back systems. Practices used in glycol systems may give serious failures. Key-words: Drain Back, Low Flow, Solar Combi System, ETC collectors....

  2. Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple’s Operation

    Directory of Open Access Journals (Sweden)

    Sang Ho Bae

    2011-05-01

    Full Text Available A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.

  3. Perioperative lumbar drain utilization in transsphenoidal pituitary resection.

    Science.gov (United States)

    Alharbi, Shatha; Harsh, Griffith; Ajlan, Abdulrazag

    2018-01-01

    To evaluate lumbar drain (LD) efficacy in transnasal resection of pituitary macroadenomas in preventing postoperative cerebrospinal fluid (CSF) leak, technique safety, and effect on length of hospital stay. We conducted a retrospective data review of pituitary tumor patients in our institution who underwent surgery between December 2006 and January 2013. All patients were operated on for complete surgical resection of pituitary macroadenoma tumors. Patients were divided into 2 groups: group 1 received a preoperative drain, while LD was not preoperatively inserted in group 2. In cases of tumors with suprasellar extension with anticipation of high-flow leak, LD was inserted after the patient was intubated and in a lateral position. Lumbar drain was used for 48 hours, and the drain was removed if no leak was observed postoperatively. In documented postoperative CSF leak patients with no preoperative drain, the leak was treated by LD trial prior to surgical reconstruction. Cases in which leak occurred 6 months postoperatively were excluded. Our study population consisted of 186 patients, 99 women (53%) and 87 men (47%), with a mean age of 50.3+/-16.1 years. Complications occurred in 7 patients (13.7%) in group 1 versus 21 (15.5%) in group 2 (p=0.72). Postoperative CSF leak was observed in 1 patient (1.9%) in group 1 and 7 (5%) in group 2 (Fisher exact test=0.3). Length of hospital stay was a mean of 4.7+/-1.9 days in group 1 and a mean of 2.7+/-2.4 days in group 2 (pLD insertion is generally considered safe with a low risk of complications, it increases the length of hospitalization. Minor complications include headaches and patient discomfort.

  4. Noise performance in AlGaN/GaN HEMTs under high drain bias

    International Nuclear Information System (INIS)

    Pang Lei; Pu Yan; Lin Xinyu; Wang Liang; Liu Jian

    2009-01-01

    The advent of fully integrated GaN PA-LNA circuits makes it meaningful to investigate the noise performance under high drain bias. However, noise performance of AlGaN/GaN HEMTs under high bias has not received worldwide attention in theoretical studies due to its complicated mechanisms. The noise value is moderately higher and its rate of increase is fast with increasing high voltage. In this paper, several possible mechanisms are proposed to be responsible for it. Impact ionization under high electric field incurs great fluctuation of carrier density, which increases the drain diffusion noise. Besides, higher gate leakage current related shot noise and a more severe self-heating effect are also contributors to the noise increase at high bias. Analysis from macroscopic and microscopic perspectives can help us to design new device structures to improve noise performance of AlGaN/GaN HEMTs under high bias. (semiconductor devices)

  5. Effectiveness of submerged drains in reducing subsidence of peat soils in agricultural use, and their effects on water management and nutrient loading of surface water: modelling of a case study in the western peat soil area of The Netherlands

    Science.gov (United States)

    Hendriks, Rob F. A.; van den Akker, Jan J. A.

    2017-04-01

    Effectiveness of submerged drains in reducing subsidence of peat soils in agricultural use, and their effects on water management and nutrient loading of surface water: modelling of a case study in the western peat soil area of The Netherlands In the Netherlands, about 8% of the area is covered by peat soils. Most of these soils are in use for dairy farming and, consequently, are drained. Drainage causes decomposition of peat by oxidation and accordingly leads to surface subsidence and greenhouse gas emission. Submerged drains that enhance submerged infiltration of water from ditches during the dry and warm summer half year were, and are still, studied in The Netherlands as a promising tool for reducing peat decomposition by raising groundwater levels. For this purpose, several pilot field studies in the Western part of the Dutch peat area were conducted. Besides the effectiveness of submerged drains in reducing peat decomposition and subsidence by raising groundwater tables, some other relevant or expected effects of these drains were studied. Most important of these are water management and loading of surface water with nutrients nitrogen, phosphorus and sulphate. Because most of these parameters are not easy to assess and all of them are strongly depending on the meteorological conditions during the field studies some of these studies were modelled. The SWAP model was used for evaluating the hydrological results on groundwater table and water discharge and recharge. Effects of submerged drains were assessed by comparing the results of fields with and without drains. An empirical relation between deepest groundwater table and subsidence was used to convert effects on groundwater table to effects on subsidence. With the SWAP-ANIMO model nutrient loading of surface water was modelled on the basis of field results on nutrient concentrations . Calibrated models were used to assess effects in the present situation, as thirty-year averages, under extreme weather

  6. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  7. Modeling of cylindrical surrounding gate MOSFETs including the fringing field effects

    International Nuclear Information System (INIS)

    Gupta, Santosh K.; Baishya, Srimanta

    2013-01-01

    A physically based analytical model for surface potential and threshold voltage including the fringing gate capacitances in cylindrical surround gate (CSG) MOSFETs has been developed. Based on this a subthreshold drain current model has also been derived. This model first computes the charge induced in the drain/source region due to the fringing capacitances and considers an effective charge distribution in the cylindrically extended source/drain region for the development of a simple and compact model. The fringing gate capacitances taken into account are outer fringe capacitance, inner fringe capacitance, overlap capacitance, and sidewall capacitance. The model has been verified with the data extracted from 3D TCAD simulations of CSG MOSFETs and was found to be working satisfactorily. (semiconductor devices)

  8. Management of extensive surgical emphysema with subcutaneous drain: A case report

    Directory of Open Access Journals (Sweden)

    Quoc Tran

    Full Text Available Introduction: Subcutaneous emphysema (SE is a frequent and often self-limiting complication of tube thoracostomy or other cardiothoracic procedures. On rare occasions, severe and extensive surgical emphysema marked by palpable cutaneous tension, dysphagia, dysphonia, palpebral closure or associated with pneumoperitoneum, airway compromise, “tension phenomenon” and respiratory failure require treatment. Presentation of case: A 67 year old lady presented with a large spontaneous pneumothorax on the background of end-stage chronic obstructive pulmonary disease (COPD and newly diagnosed lung cancer, developed extensive surgical emphysema following insertion of a chest drain. Immediate improvement was observed after insertion of a large-bore, 26 French (Fr. intercostal catheter, subcutaneous drain which was maintained under low suction (−5 cm H2O for a further 24 h. Discussion: Several methods have been described in the literature for the treatment of extensive subcutaneous emphysema, including: emergency tracheostomy, multisite subcutaneous drainage, infraclavicular “blow holes” incisions and subcutaneous drains or simply increasing suction on an in situ chest drain. Here a large-bore, fenestrated, subcutaneous drain maintained on low negative pressure also provided the necessary decompression. Conclusion: In the absence of a comparative study to identify the most effective method to manage extensive subcutaneous emphysema, this case highlights an effective, simple and safe management option. Keywords: Pneumothorax, Subcutaneous emphysema, Drain, Low suction, Intercostal catheter, Case report

  9. Rapid breakthrough of pesticides via biopres into tile drains and shallow groundwater: a combined experimental and model study

    Science.gov (United States)

    Klaus, J.; Zehe, E.; Palm, J.; Schroeder, B.

    2009-04-01

    vertical soil profiles were excavated on the first day after the irrigation and two vertical profiles were excavated one week after the experiment. In those profiles soil samples were taken in a 10cm*10cm grid to analyse for the tracer concentrations. Based on that information the probability distribution function of the travel depths for each tracer could be calculated for two points in time. As burrows of deep digging earth worms often act as preferential pathways we counted the individuals of worm burrows using a nested sampling procedure. Though endogeic earthworms were apparent we didn't find any individuals of Lumbricus Terrestris nor macropores with diameter larger than 2 mm at a depth larger than 30-35 cm. So far we didn't identify those pathways that caused this rapid pesticide breakthrough into the tile drain, though a very small number macropores would suffice. Based on the collected data we will setup up a numerical model to simulate observed and flow and transport and test the hypothesis that earthworm burrows are the reason for this rapid breakthrough of pesticides into the tile drain.

  10. Investigation of radiation safety management at nuclear medicine facilities in Japan. Contamination of radioactivity in the draining-water system

    International Nuclear Information System (INIS)

    Endo, Keigo; Koizumi, Mitsuru; Kinoshita, Fujimi; Nakazawa, Keiji

    1999-01-01

    Radiation-safety management condition in Japanese nuclear medicine facilities were investigated by the questionnaire method. The first questionnaire was asked in all Japanese 1,401 Nuclear Medicine facilities. Answers from 624 institutes (44.5%) were received and analyzed. The radiation-safety management in nuclear medicine institutes was considered to be very well performed everyday. Opinion for the present legal control of nuclear medicine institutes was that the regulation in Japan was too strict for the clinical use of radionuclides. The current regulation is based on the assumption that 1% of all radioactivity used in nuclear medicine institutes contaminates into the draining-water system. The second questionnaire detailing the contamination of radioactivity in the draining-water system was sent to 128 institutes, and 64 answers were received. Of them, 42 institutes were considered to be enough to evaluate the contamination of radioactivity in the draining-water system. There was no difference between 624 institutes answered to the first questionnaire and 42 institutes, where the radioactivity in the draining-water system measured, in the distribution of the institute size, draining-water system equipment and the radioactivity measuring method, and these 42 institutes seemed to be representative of Japanese nuclear medicine institutes. Contamination rate of radioactivity into the draining system was calculated by the value of radioactivity in the collecting tank divided by the amount of radionuclides used daily in each institute. The institutes were divided into two categories on the basis of nuclear medicine practice pattern; type A: in-vivo use only and type B: both in-vivo and in-vitro use. The contamination rate in 27 type A institutes did not exceed 0.01%, whereas in 15 type B institutes the contamination rate distributed widely from undetectable to above 1%. These results indicated that the present regulation for the draining-water system, which assumed

  11. Numerical simulation of the transient thermal-hydraulic behaviour of the ITER blanket cooling system under the draining operational procedure

    Energy Technology Data Exchange (ETDEWEB)

    Di Maio, P.A. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy); Dell’Orco, G.; Furmanek, A. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Garitta, S. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy); Merola, M.; Mitteau, R.; Raffray, R. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Spagnuolo, G.A. [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy); Vallone, E., E-mail: eug.vallone@gmail.com [Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici, Università di Palermo Viale delle Scienze, 90128 Palermo (Italy)

    2015-10-15

    Highlights: • ITER blanket cooling system hydraulic behaviour is studied under draining transient. • A computational approach based on the finite volume method has been followed. • Draining efficiency has been assessed in term of transient duration and residual water. • Transient duration ranges from ∼40 to 50 s, under the reference draining scenario. • Residual water is predicted to range from few tens of gram up to few kilograms. - Abstract: Within the framework of the research and development activities supported by the ITER Organization on the blanket system issues, an intense analysis campaign has been performed at the University of Palermo with the aim to investigate the thermal-hydraulic behaviour of the cooling system of a standard 20° sector of ITER blanket during the draining transient operational procedure. The analysis has been carried out following a theoretical-computational approach based on the finite volume method and adopting the RELAP5 system code. In a first phase, attention has been focused on the development and validation of the finite volume models of the cooling circuits of the most demanding modules belonging to the standard blanket sector. In later phase, attention has been put to the numerical simulation of the thermal-hydraulic transient behaviour of each cooling circuit during the draining operational procedure. The draining procedure efficiency has been assessed in terms of both transient duration and residual amount of coolant inside the circuit, observing that the former ranges typically between 40 and 120 s and the latter reaches at most ∼8 kg, in the case of the cooling circuit of twinned modules #6–7. Potential variations to operational parameters and/or to circuit lay-out have been proposed and investigated to optimize the circuit draining performances. In this paper, the set-up of the finite volume models is briefly described and the key results are summarized and critically discussed.

  12. A retrospective study of the use of active suction wound drains in dogs and cats.

    Science.gov (United States)

    Bristow, P C; Halfacree, Z J; Baines, S J

    2015-05-01

    To report indications for use and complications associated with commonly used closed active suction wound drains in a large number of clinical cases. Retrospective review of medical case records (from 2004 to 2010) for dogs and cats that had a closed active suction drain placed into a wound. Only the four most common drain types were included: Mini Redovac®, Redovac®, Jackson Pratt® and Wound Evac®. Two hundred and fifty-three drains were placed in 33 cats and 195 dogs. Mini Redovac drains were used most frequently in cats (76 · 5%) and Redovac drains in dogs (54 · 3%). The infection rate for clean surgeries in dogs was 15 · 6% (unattainable in cats). Major complications occurred in four dogs; minor complications occurred in 12 drains in cats (35 · 3%), and in 74 drains in dogs (33 · 8%). There was no statistically significant association between the type of drain and complication rate for either species. Although closed active suction drains can be used with low risk of major complications, they lead to a high rate of infection in clean surgeries in dogs. It is recommended that such drains are kept in place for the shortest time possible and that strict asepsis is adhered to both during placement and management. © 2015 British Small Animal Veterinary Association.

  13. Comparative Evaluation of Immediate Post-Operative Sequelae after Surgical Removal of Impacted Mandibular Third Molar with or without Tube Drain - Split-Mouth Study.

    Science.gov (United States)

    Kumar, Barun; Bhate, Kalyani; Dolas, R S; Kumar, Sn Santhosh; Waknis, Pushkar

    2016-12-01

    Third molar surgery is one of the most common surgical procedures performed in general dentistry. Post-operative variables such as pain, swelling and trismus are major concerns after impacted mandibular third molar surgery. Use of passive tube drain is supposed to help reduce these immediate post-operative sequelae. The current study was designed to compare the effect of tube drain on immediate post-operative sequelae following impacted mandibular third molar surgery. To compare the post-operative sequelae after surgical removal of impacted mandibular third molar surgery with or without tube drain. Thirty patients with bilateral impacted mandibular third molars were divided into two groups: Test (with tube drain) and control (without tube drain) group. In the test group, a tube drain was inserted through the releasing incision, and kept in place for three days. The control group was left without a tube drain. The post-operative variables like, pain, swelling, and trismus were calculated after 24 hours, 72 hours, 7 days, and 15 days in both the groups and analyzed statistically using chi-square and t-test analysis. The test group showed lesser swelling as compared to control group, with the swelling variable showing statistically significant difference at post-operative day 3 and 7 (p≤ 0.05) in both groups. There were no statistically significant differences in pain and trismus variables in both the groups. The use of tube drain helps to control swelling following impacted mandibular third molar surgery. However, it does not have much effect on pain or trismus.

  14. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  15. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  16. Theory of Maxwell's fish eye with mutually interacting sources and drains

    Science.gov (United States)

    Leonhardt, Ulf; Sahebdivan, Sahar

    2015-11-01

    Maxwell's fish eye is predicted to image with a resolution not limited by the wavelength of light. However, interactions between sources and drains may ruin the subwavelength imaging capabilities of this and similar absolute optical instruments. Nevertheless, as we show in this paper, at resonance frequencies of the device, an array of drains may resolve a single source, or alternatively, a single drain may scan an array of sources, no matter how narrowly spaced they are. It seems that near-field information can be obtained from far-field distances.

  17. Management of Chest Drains: A National Survey on Surgeons‑in ...

    African Journals Online (AJOL)

    triangle of safety [Figure 1]. Just above a quarter of respondents (27.2%) always utilized different sizes of tubes for different pathologies and the same proportion of respondents always positioned the tip of the tube apically to drain pneumothorax and basally to drain pleural effusion. In contrast, 9.9% and 6.2% of respondents.

  18. Cold Vacuum Drying facility effluent drain system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) effluent drain system (EFS). The primary function of the EFS is to collect and transport fire suppression water discharged into a CVDF process bay to a retention basin located outside the facility. The EFS also provides confinement of spills that occur inside a process bay and allows non-contaminated water that drains to the process bay sumps to be collected until sampling and analysis are complete

  19. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    International Nuclear Information System (INIS)

    Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.; Joslyn, Cameron C.; Vazquez, Brandon J.; Venetz, Theodore J.; Garfield, John S.

    2014-01-01

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line

  20. Effect of an intervention in storm drains to prevent Aedes aegypti reproduction in Salvador, Brazil.

    Science.gov (United States)

    Souza, Raquel Lima; Mugabe, Vánio André; Paploski, Igor Adolfo Dexheimer; Rodrigues, Moreno S; Moreira, Patrícia Sousa Dos Santos; Nascimento, Leile Camila Jacob; Roundy, Christopher Michael; Weaver, Scott C; Reis, Mitermayer Galvão; Kitron, Uriel; Ribeiro, Guilherme Sousa

    2017-07-11

    Aedes aegypti, the principal vector for dengue, chikungunya and Zika viruses, is a synanthropic species that uses stagnant water to complete its reproductive cycle. In urban settings, rainfall water draining structures, such as storm drains, may retain water and serve as a larval development site for Aedes spp. reproduction. Herein, we describe the effect of a community-based intervention on preventing standing water accumulation in storm drains and their consequent infestation by adult and immature Ae. aegypti and other mosquitoes. Between April and May of 2016, local residents association of Salvador, Brazil, after being informed of water accumulation and Ae. aegypti infestation in the storm drains in their area, performed an intervention on 52 storm drains. The intervention consisted of placing concrete at the bottom of the storm drains to elevate their base to the level of the outflow tube, avoiding water accumulation, and placement of a metal mesh covering the outflow tube to avoid its clogging with debris. To determine the impact of the intervention, we compared the frequency at which the 52 storm drains contained water, as well as adult and immature mosquitoes using data from two surveys performed before and two surveys performed after the intervention. During the pre-intervention period, water accumulated in 48 (92.3%) of the storm drains, and immature Ae. aegypti were found in 11 (21.2%) and adults in 10 (19.2%). After the intervention, water accumulated in 5 (9.6%) of the storm drains (P Aedes mosquitoes (mainly Culex spp.) in the storm drains also decreased after the intervention. This study exemplifies how a simple intervention targeting storm drains can result in a major reduction of water retention, and, consequently, impact Ae. aegypti larval populations. Larger and multi-center evaluations are needed to confirm the potential of citywide structural modifications of storm drains to reduce Aedes spp. infestation level.

  1. Drain-Site Hernia Containing the Vermiform Appendix: Report of a Case

    Directory of Open Access Journals (Sweden)

    Markus Gass

    2013-01-01

    Full Text Available The herniated vermiform appendix has been described as content of every hernia orifice in the right lower quadrant. While the femoral and inguinal herniated vermiform appendix is frequent enough to result in an own designation, port-site or even drain-site hernias are less frequently described. We report the case of a 62-year-old woman who presented with right lower quadrant pain seven years after Roux-en-Y Cystojejunostomy for a pancreatic cyst. CT scan showed herniation of the vermiform appendix through a former drain-site. A diagnostic laparoscopy with appendectomy and direct closure of the abdominal wall defect combined with mesh reinforcement was performed. Despite the decreasing use of intraperitoneal drains over the recent years, a multitude of patients had intraperitoneal drainage in former times. These patients face nowadays the risk of drain-site hernias with sometimes even unexpected structures inside.

  2. Double-gate junctionless transistor model including short-channel effects

    International Nuclear Information System (INIS)

    Paz, B C; Pavanello, M A; Ávila-Herrera, F; Cerdeira, A

    2015-01-01

    This work presents a physically based model for double-gate junctionless transistors (JLTs), continuous in all operation regimes. To describe short-channel transistors, short-channel effects (SCEs), such as increase of the channel potential due to drain bias, carrier velocity saturation and mobility degradation due to vertical and longitudinal electric fields, are included in a previous model developed for long-channel double-gate JLTs. To validate the model, an analysis is made by using three-dimensional numerical simulations performed in a Sentaurus Device Simulator from Synopsys. Different doping concentrations, channel widths and channel lengths are considered in this work. Besides that, the series resistance influence is numerically included and validated for a wide range of source and drain extensions. In order to check if the SCEs are appropriately described, besides drain current, transconductance and output conductance characteristics, the following parameters are analyzed to demonstrate the good agreement between model and simulation and the SCEs occurrence in this technology: threshold voltage (V TH ), subthreshold slope (S) and drain induced barrier lowering. (paper)

  3. Brain drain: a challenge to global mental health.

    Science.gov (United States)

    Oladeji, Bibilola D; Gureje, Oye

    2016-08-01

    The brain drain of medical professionals from lower-income to higher-income countries contributes to the current inequity that characterises access to mental healthcare by those in need across the world and hinders efforts to scale up mental health services in resource-constrained settings, especially in Nigeria and other West African countries. The migration of skilled workers is driven by a combination of the globalisation of the labour market and the ability of highly resourced countries to attract and retain specialists from poorer countries. If we are to ameliorate the worldwide shortage of mental health professionals, we need to find innovative ways of attracting young doctors into psychiatric training in all countries. We must also introduce measures to improve health worker retention in low- and middle-income countries.

  4. Optimization design for drain to nuclear power condenser

    International Nuclear Information System (INIS)

    Ding Jiapeng; Jiang Chengren

    2010-01-01

    Characters and varieties of drain to nuclear power condenser are discussed in this paper. Take the main steam system of a nuclear power as an example, normal and detailed optimization design are introduced, related expatiate are used as a reference for the drain of other systems. According to the characters of nuclear power instant operation, the influence and needed actions related with the optimization design are also analyzed. Based on the above research, the scheme has been carried out in a nuclear power station and safety for the condenser operation of the nuclear power has been improved largely. (authors)

  5. Short-channel drain current model for asymmetric heavily / lightly ...

    Indian Academy of Sciences (India)

    PRADIPTA DUTTA

    2017-07-29

    Jul 29, 2017 ... (2017) 89:33 ... MS received 25 August 2015; revised 6 March 2017; accepted 6 April 2017; published ..... [18] J P Colinge, J W Park and W Xiong, IEEE Electron. ... devices(Cambridge University Press, Cambridge, 1998).

  6. Estimating drain flow from measured water table depth in layered soils under free and controlled drainage

    Science.gov (United States)

    Saadat, Samaneh; Bowling, Laura; Frankenberger, Jane; Kladivko, Eileen

    2018-01-01

    Long records of continuous drain flow are important for quantifying annual and seasonal changes in the subsurface drainage flow from drained agricultural land. Missing data due to equipment malfunction and other challenges have limited conclusions that can be made about annual flow and thus nutrient loads from field studies, including assessments of the effect of controlled drainage. Water table depth data may be available during gaps in flow data, providing a basis for filling missing drain flow data; therefore, the overall goal of this study was to examine the potential to estimate drain flow using water table observations. The objectives were to evaluate how the shape of the relationship between drain flow and water table height above drain varies depending on the soil hydraulic conductivity profile, to quantify how well the Hooghoudt equation represented the water table-drain flow relationship in five years of measured data at the Davis Purdue Agricultural Center (DPAC), and to determine the impact of controlled drainage on drain flow using the filled dataset. The shape of the drain flow-water table height relationship was found to depend on the selected hydraulic conductivity profile. Estimated drain flow using the Hooghoudt equation with measured water table height for both free draining and controlled periods compared well to observed flow with Nash-Sutcliffe Efficiency values above 0.7 and 0.8 for calibration and validation periods, respectively. Using this method, together with linear regression for the remaining gaps, a long-term drain flow record for a controlled drainage experiment at the DPAC was used to evaluate the impacts of controlled drainage on drain flow. In the controlled drainage sites, annual flow was 14-49% lower than free drainage.

  7. Estimation of local and regional components of drain - flow from an irrigated field

    International Nuclear Information System (INIS)

    Eching, S.O.; Hopmans, J.W.; Wallender, W.W.; Macyntyre, J.L.; Peters, D.

    1995-01-01

    The contribution of regional ground water and deep percolation from a furrow irrigated field to total drain flow was estimated using salt load analysis. It was found that 64% of the drain flow comes from regional ground water flow. The electrical conductivity of the drain water was highly correlated with the drain flow rate. From the field water balance with deep percolation as estimated from the salt load analysis, using yield function derived evapotranspiration, and measured changes in root zone water storage, it was shown that 14% of the crop evapotranspiration comes from ground water during the study period. 8 figs; 5 tabs; 15 refs ( Author )

  8. Ensemble Monte Carlo particle investigation of hot electron induced source-drain burnout characteristics of GaAs field-effect transistors

    Science.gov (United States)

    Moglestue, C.; Buot, F. A.; Anderson, W. T.

    1995-08-01

    The lattice heating rate has been calculated for GaAs field-effect transistors of different source-drain channel design by means of the ensemble Monte Carlo particle model. Transport of carriers in the substrate and the presence of free surface charges are also included in our simulation. The actual heat generation was obtained by accounting for the energy exchanged with the lattice of the semiconductor during phonon scattering. It was found that the maximum heating rate takes place below the surface near the drain end of the gate. The results correlate well with a previous hydrodynamic energy transport estimate of the electronic energy density, but shifted slightly more towards the drain. These results further emphasize the adverse effects of hot electrons on the Ohmic contacts.

  9. Reverse blocking characteristics and mechanisms in Schottky-drain AlGaN/GaN HEMT with a drain field plate and floating field plates

    International Nuclear Information System (INIS)

    Mao Wei; She Wei-Bo; Zhang Jin-Feng; Zheng Xue-Feng; Wang Chong; Hao Yue; Yang Cui

    2016-01-01

    In this paper, a novel AlGaN/GaN HEMT with a Schottky drain and a compound field plate (SD-CFP HEMT) is presented for the purpose of better reverse blocking capability. The compound field plate (CFP) consists of a drain field plate (DFP) and several floating field plates (FFPs). The physical mechanisms of the CFP to improve the reverse breakdown voltage and to modulate the distributions of channel electric field and potential are investigated by two-dimensional numerical simulations with Silvaco-ATLAS. Compared with the HEMT with a Schottky drain (SD HEMT) and the HEMT with a Schottky drain and a DFP (SD-FP HEMT), the superiorities of SD-CFP HEMT lie in the continuous improvement of the reverse breakdown voltage by increasing the number of FFPs and in the same fabrication procedure as the SD-FP HEMT. Two useful optimization laws for the SD-CFP HEMTs are found and extracted from simulation results. The relationship between the number of the FFPs and the reverse breakdown voltage as well as the FP efficiency in SD-CFP HEMTs are discussed. The results in this paper demonstrate a great potential of CFP for enhancing the reverse blocking ability in AlGaN/GaN HEMT and may be of great value and significance in the design and actual manufacture of SD-CFP HEMTs. (paper)

  10. Laparoscopic primary repair and isoperistaltic endoluminal drain for Boerhaave's Syndrome.

    Science.gov (United States)

    Prete, Francesco; Pezzolla, Angela; Nitti, Paolo; Prete, Fernando

    2015-01-01

    Spontaneous oesophageal rupture, also known as Boerhaave syndrome (BS), is a rare and potentially lethal pathological condition. BS recognition is difficult, while rapidity of diagnosis, along with extension of the lesion, affects type and outcome of treatment. BS was classically treated by thoracotomy, but laparoscopic (LS), thoracoscopic (TS) surgery, and nonsurgical procedures as endoscopic stent positioning or use of glues have been described. Still, there is no model treatment, and selection of the most appropriate therapeutic procedure is complex in the absence of standardised criteria. We successfully managed a patient affected with BS by LS approach and present our experience along with a review of treatment options so far described. Our treatment integrated positioning of an oesophageal isoperistaltic endoluminal drain (IED), that we routinely use in oesophageal sutures at risk of leakage, and of which there is no previous report in the setting of BS. A 68 year old man presented to our attention with true BS, suspected on chest-abdominal CT scan and confirmed by upper GI contrast swallow test, showing leakage of hydro-soluble contrast from the lower third of the oesophagus. Of note, pleural cavities appeared intact. We performed an urgent laparoscopy 12 hours after the onset of symptoms. Laparoscopic toilet of the inferior mediastinum and dual layer oesophageal repair with pedicled omental flap were complemented by positioning of IED, feeding jejunostomy and two tubular drains. The patient had a slow but consistent recovery where IED played as a means of oesophageal suture protection, until he could be discharged home. We think that, when integrity of the pleura is documented, LS should be priority choice to avoid contamination of the pleural cavities. We have to consider every type of oesophageal repair in BS at risk of failure, and every means of protection of the suture is opportune. In our patient the oesophageal suture, covered with a flap of omentum

  11. Investigation of defect-induced abnormal body current in fin field-effect-transistors

    International Nuclear Information System (INIS)

    Liu, Kuan-Ju; Tsai, Jyun-Yu; Lu, Ying-Hsin; Liu, Xi-Wen; Chang, Ting-Chang; Chen, Ching-En; Yang, Ren-Ya; Cheng, Osbert; Huang, Cheng-Tung

    2015-01-01

    This letter investigates the mechanism of abnormal body current at the linear region in n-channel high-k/metal gate stack fin field effect transistors. Unlike body current, which is generated by impact ionization at high drain voltages, abnormal body current was found to increase with decreasing drain voltages. Notably, the unusual body leakage only occurs in three-dimensional structure devices. Based on measurements under different operation conditions, the abnormal body current can be attributed to fin surface defect-induced leakage current, and the mechanism is electron tunneling to the fin via the defects, resulting in holes left at the body terminal

  12. Thailand and brain drain

    OpenAIRE

    Terry Commins

    2009-01-01

    Brain drain has been the subject of research since the 1960s. This research has been hampered by a lack of accurate data from both source and receiving countries on migration and on the losses and gains to developing economies of skilled migration. However, despite these handicaps, research has been able to clearly show that trends are changing and the effect this is having is usually quite different for individual source countries.Thailand, as a developing economy, could be regarded as a sou...

  13. The sensitivity research of multiparameter biosensors based on HEMT by the mathematic modeling method

    Science.gov (United States)

    Tikhomirov, V. G.; Gudkov, A. G.; Agasieva, S. V.; Gorlacheva, E. N.; Shashurin, V. D.; Zybin, A. A.; Evseenkov, A. S.; Parnes, Y. M.

    2017-11-01

    The numerical impact modeling of some external effects on the CVC of biosensors based on AlGaN/GaN heterostructures (HEMT) was carried out. The mathematical model was created that allowed to predict the behavior of the drain current depending on condition changes on the heterostructure surface in the gate region and to start the process of directed construction optimization of the biosensors based on AlGaN/GaN HEMT with the aim of improving their performance. The calculation of the drain current of the biosensor construction was carried out to confirm the reliability of the developed mathematical model and obtained results.

  14. The European Politics of Brain Drain

    DEFF Research Database (Denmark)

    Hasselbalch, Jacob

    This qualitative multi-method studymaps the politics of brain drain at the level of the European Union and follows the evolution of the issue over the last four parliamentary periods. By utilizing a novel combination of interviews with a content and network analysis of parliamentary questions...

  15. An economic perspective on Malawi's medical "brain drain"

    Directory of Open Access Journals (Sweden)

    Mohiddin Abdu

    2006-12-01

    Full Text Available Abstract Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production" of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a

  16. An economic perspective on Malawi's medical "brain drain"

    Science.gov (United States)

    Record, Richard; Mohiddin, Abdu

    2006-01-01

    Background The medical "brain drain" has been described as rich countries "looting" doctors and nurses from developing countries undermining their health systems and public health. However this "brain-drain" might also be seen as a success in the training and "export" of health professionals and the benefits this provides. This paper illustrates the arguments and possible policy options by focusing on the situation in one of the poorest countries in the world, Malawi. Discussion Many see this "brain drain" of medical staff as wrong with developed countries exploiting poorer ones. The effects are considerable with Malawi facing high vacancy rates in its public health system, and with migration threatening to outstrip training despite efforts to improve pay and conditions. This shortage of staff has made it more challenging for Malawi to deliver on its Essential Health Package and to absorb new international health funding. Yet, without any policy effort Malawi has been able to demonstrate its global competitiveness in the training ("production") of skilled health professionals. Remittances from migration are a large and growing source of foreign exchange for poor countries and tend to go directly to households. Whilst the data for Malawi is limited, studies from other poor countries demonstrate the power of remittances in significantly reducing poverty. Malawi can benefit from the export of health professionals provided there is a resolution of the situation whereby the state pays for training and the benefits are gained by the individual professional working abroad. Solutions include migrating staff paying back training costs, or rich host governments remitting part of a tax (e.g. income or national insurance) to the Malawi government. These schemes would allow Malawi to scale up training of health professionals for local needs and to work abroad. Summary There is concern about the negative impacts of the medical "brain-drain". However a closer look at the evidence

  17. Reduction in wick drain effectiveness with spacing for Utah silts and clays.

    Science.gov (United States)

    2012-04-01

    Although decreasing the spacing of vertical drains usually decreases the time for consolidation, previous field tests have shown that there is a critical drain spacing for which tighter spacing does not decrease the time for consolidation. This...

  18. Processing method of radioactive cleaning drain

    International Nuclear Information System (INIS)

    Otsuka, Shigemitsu; Murakami, Tadashi; Kitao, Hideo

    1998-01-01

    Upon processing of radioactive cleaning drains, contained Co-60 is removed by a selectively adsorbing adsorbent. In addition, after removing suspended materials by a filtering device, Co-60 as predominant nuclides in the drain is selectively adsorbed. The concentration of objective Co-60 is in the order of 0.1 Bq/cc, and non-radioactive metal ions such as Na + ions are present in the order of ppm in addition to Co-60. A granular adsorbent for selectively adsorbing Co-60 is oxine-added activated carbon, and has a grain size of from 20 to 48 mesh. The granular adsorbent is used while being filled in an adsorbing tower. Since a relatively simple device comprising the filtering device and the adsorbing tower in combination is provided, the reduction of the construction cost can be expected. In addition, since no filtering aid is used in the filtering device, the amount of secondary wastes is small. (N.H.)

  19. Autologous transfusion of drain contents in elective primary knee arthroplasty: its value and relevance.

    Science.gov (United States)

    Singh, Vinay Kumar; Singh, Pankaj Kumar; Javed, Sadaf; Kumar, Kuldeep; Tomar, Juhi

    2011-07-01

    Total knee arthroplasty is associated with significant post-operative blood loss often necessitating blood transfusions. Blood transfusions may be associated with transfusion reactions and may transmit human immunodeficiency virus, hepatitis C virus and hepatitis B virus, with devastating consequences. After total knee arthroplasty, transfusion of the contents of an autologous drain is becoming common practice. The aim of our study was to look at the effectiveness of these drains in elective primary total knee arthroplasty. A prospective study was conducted including 70 non-randomised patients. A normal suction drain was used in 35 patients (group A), whereas in the other 35 patients, a CellTrans™ drain was used (group B). All the operations were performed by four surgeons using a tourniquet with a medial parapatellar approach. Pre- and post-operative haemoglobin concentrations were recorded in both groups. A Student's t-test was applied to determine the statistical significance of the data collected. The average fall in post-operative haemoglobin was 3.66 g/dL (SD 1.46; range, 0.6-7.0) among patients in whom the simple drain was used (group A) and 2.29 g/dL (SD 0.92; range, 0.6-5.9) among those in whom the CellTrans™ drain was used (group B) (p<0.0001). Twenty-five units of allogeneic blood were required in group A compared to four units in group B. The rate of transfusion was 5.7% (2 patients) in the group in which CellTrans™ drain was used and 25.7% (9 patients) in the group in which a simple suction drain was used. Total knee arthroplasty is associated with significant post-operative blood loss despite best operative technique. Autologous reinfusion of the contents of a CellTrans™ drain significantly reduces the rate of post-operative blood transfusion. This study indicates that the use of an autologous drain could be recommended as routine practice in primary total knee arthroplasty.

  20. Is a drain tube necessary for minimally invasive lumbar spine fusion surgery?

    Science.gov (United States)

    Hung, Pei-I; Chang, Ming-Chau; Chou, Po-Hsin; Lin, Hsi-Hsien; Wang, Shih-Tien; Liu, Chien-Lin

    2017-03-01

    This study aimed to evaluate if closed suction wound drainage is necessary in minimally invasive surgery of transforaminal lumbar interbody fusion (MIS TLIF). This is a prospective randomized clinical study. Fifty-six patients who underwent MIS TLIF were randomly divided into groups A (with a closed suction wound drainage) and B (without tube drainage). Surgical duration, intraoperative blood loss, timing of ambulation, length of hospital stay and complications were recorded. Patients were followed up for an average of 25.3 months. Clinical outcome was assessed using the Oswestry disability index and visual analogue scale (VAS). Fusion rate was classified with the Bridwell grading system, based on plain radiograph. Both groups had similar patient demographics. The use of drains had no significant influence on perioperative parameters including operative time, estimated blood loss, length of stay and complications. Patients in group B started ambulation 1 day earlier than patients in group A (p drain tube can lead to pain, anxiety and discomfort during the postoperative period. We conclude that drain tubes are not necessary for MIS TLIF. Patients without drains had the benefit of earlier ambulation than those with drains.

  1. Nurses’ knowledge of care of chest drain: A survey in a Nigerian semiurban university hospital

    Science.gov (United States)

    Kesieme, Emeka Blessius; Essu, Ifeanyichukwu Stanley; Arekhandia, Bruno Jeneru; Welcker, Katrin; Prisadov, Georgi

    2016-01-01

    Background/Objective: Inefficient nursing care of chest drains may associated with unacceptable and sometimes life-threatening complications. This report aims to ascertain the level of knowledge of care of chest drains among nurses working in wards in a teaching hospital in Nigeria. Methods: A cross-sectional study among nurses at teaching hospital using pretested self-administered questionnaires. Results: The majority were respondents aged between 31 and 40 years (45.4%) and those who have nursing experience between 6 and 10 years. Only 37 respondents (26.2%) had a good knowledge of nursing care of chest drains. Knowledge was relatively higher among nurses who cared for chest drains daily, nurses who have a work experience of 0.05). Performance was poor on the questions on position of drainage system were not statistically significant with relationship to waist level while mobilizing the patient, application of suction to chest drains, daily changing of dressing over chest drain insertion site, milking of tubes and drainage system with dependent loop. Conclusion: The knowledge of care of chest drains among nurses is poor, especially in the key post procedural care. There is an urgent need to train them so as to improve the nursing care of patients managed with chest drains. PMID:26857934

  2. Drainage of shallow peat harvesting areas with pipe drains; Madaltuneen turvetuotantokentaen kuivatustutkimus

    Energy Technology Data Exchange (ETDEWEB)

    Klemetti, V. [Vapo Oy, Jyvaeskylae (Finland)

    1997-12-01

    This study aims to develop pipe draining techniques in peat harvesting areas, which have been in active use so long time that the remaining peat layer is about one meter thick. The method should be technically and economically feasible as well as environmentally acceptable. Special attention is paid to pipe installation techniques, drain spacing and impacts on watercourses, which receive the drainage waters. After pipe installation the area was monitored by measuring pipe runoffs, water tables, moisture content of peat and quality of drain water. These are the results of second year. (orig.)

  3. Draining Collars and Lenses in Liquid-Lined Vertical Tubes.

    Science.gov (United States)

    Jensen

    2000-01-01

    The speed at which an annular liquid collar drains under gravity g in a vertical tube of radius a, when the tube has an otherwise thin viscous liquid lining on its interior, is determined by a balance between the collar's weight and viscous shear stresses confined to narrow regions in the neighborhood of the collar's effective contact lines. Whether a collar grows or shrinks in volume as it drains depends on the modified Bond number B=rho g a(2)/(sigmaepsilon), where rho is the fluid density, sigma is its surface tension, and epsilona is the thickness of the thin film immediately ahead of the collar. Asymptotic methods are used here to determine the following nonlinear stability criteria for an individual collar, valid in the limit of small epsilon. For 0draining collars grow in volume and, in sufficiently long tubes, ultimately "snap off" to form stable lenses. For 0.5960drain, so that any lens ultimately ruptures, unless stabilizing intermolecular forces allow the formation of a lamella supported by a macroscopic Plateau border. If surfactant immobilizes the liquid's free surface, these critical values of B are reduced by a factor of 2 but the distance a collar must travel before it snaps off is unchanged. Gravitationally driven snap off is therefore most likely to occur in long tubes with radii substantially less than the capillary lengthscale sigma/rhog)(1/2). Copyright 2000 Academic Press.

  4. Brain drain in globalization A general equilibrium analysis from the sending countries’ perspective

    OpenAIRE

    Luca MARCHIORI; I-Ling SHEN; Frederic DOCQUIER

    2009-01-01

    The paper assesses the global effects of brain drain on developing economies and quantifies the relative sizes of various static and dynamic impacts. By constructing a unified generic framework characterized by overlapping generations dynamics and calibrated to real data, this study incorporates many direct impacts of brain drain whose interactions, along with other indirect effects, are endogenously and dynamically generated. Our findings suggest that the short-run impact of brain drain on r...

  5. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    Directory of Open Access Journals (Sweden)

    Gonzalo García-Ros

    2018-02-01

    Full Text Available The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018, a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulation Program with Integrated Circuit Emphasis (Ngspice has been used as a numerical tool while the Matrix Laboratory (MATLAB code was used to program and create an interface with the user through interactive screens. In this way, SICOMED_2018 is presented as an easy-to-use and intuitive program, with a simple graphical interface that allows the user to enter all the soil properties and geometry of the problem without having to resort to a complex software package that requires programming. Illustrative applications describe both the versatility of the program and the reliability of its numerical solutions.

  6. Brain drain from developing countries: how can brain drain be converted into wisdom gain?

    OpenAIRE

    Dodani, Sunita; LaPorte, Ronald E

    2005-01-01

    Brain drain is defined as the migration of health personnel in search of the better standard of living and quality of life, higher salaries, access to advanced technology and more stable political conditions in different places worldwide. This migration of health professionals for better opportunities, both within countries and across international borders, is of growing concern worldwide because of its impact on health systems in developing countries. Why do talented people leave their count...

  7. In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?

    Science.gov (United States)

    Johnson, Charles H N; Lang, Sommer A; Bilal, Haris; Rammohan, Kandadai S

    2014-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?'. Altogether more than 200 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Subcutaneous emphysema is usually a benign, self-limiting condition only requiring conservative management. Interventions are useful in the context of severe patient discomfort, respiratory distress or persistent air leak. In the absence of any comparative study, it is not possible to choose definitively between infraclavicular incisions, drain insertion and increasing suction on an in situ drain as the best method for managing severe subcutaneous emphysema. All the three techniques described have been shown to provide effective relief. Increasing suction on a chest tube already in situ provided rapid relief in patients developing SE following pulmonary resection. A retrospective study showed resolution in 66%, increasing to 98% in those who underwent video-assisted thoracic surgery with identification and closure of the leak. Insertion of a drain into the subcutaneous tissue also provided rapid sustained relief. Several studies aided drainage by using regular compressive massage. Infraclavicular incisions were also shown to provide rapid relief, but were noted to be more invasive and carried the potential for cosmetic defect. No major complications were illustrated. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Outcome in Chronic Subdural Hematoma After Subdural vs. Subgaleal Drain.

    Science.gov (United States)

    Ishfaq, Asim

    2017-07-01

    To compare the outcome after surgery for chronic subdural hematoma when the drain is placed in subdural space or subgaleal space. Quasi experimental study. Combined Military Hospital, Lahore, from July 2015 to June 2016. Patients with chronic subdural hematoma of both genders and age, ranging between 55 to 85 years, were included. Patients on antiplatelet/anticoagulant therapy and acute on chronic subdural hematoma were excluded. Patients were divided in two equal groups each depending on whether drain was placed in subgaleal space (Group 1), and subdual space (Group 2), (n=31 patients each). Patients were positioned flat in bed after surgery. Clinical and radiological parameters and clinical outcome were compared between the two groups. Statistical test with significance of p hematoma was 15 ±6.5 mm. Patients with subdural drain placement had more complications such as pneumocephalus 11 (35.4%) vs. 6 (19.3%), and intracerebral hemorrhage 4 (12.9%) vs. 2 (6.4%). Clinical outcome was good in both groups 27 (87%) in Group 1 and 28 (90%) in Group 2. Patients of both groups had good outcome after surgery. Complications like pneumocephalus and intracerebral hemorrhage were more common in subdural location of drain, though not reaching statistically significance level to favor one technique over another.

  9. Prefabricated vertical drains, vol. I : engineering guidelines.

    Science.gov (United States)

    1986-09-01

    This volume presents procedures and guidelines applicable to the design and instal : tion of prefabricated vertical drains to accelerate consolidation of soils. The : contents represent the Consultant's interpretation of the state-of-the-art as of : ...

  10. The effect of drains on the alkalinity of agricultural soils

    International Nuclear Information System (INIS)

    Iqbal, M.A.; Butt, T.; Anwar-ul-Haque; Haroon, M.; Haq, I.U.

    2009-01-01

    The purpose of the study was to observe the effect of industrial and domestic drains on the nearby agricultural areas which are either irrigated or not by the waste water but are close to drains. For this purpose 48 soil samples were collected from the selected areas of Faisalabad and were analyzed for alkali metals like Na/sup +/, K/sup +/, Li/sup +/ and some alkaline earth metals like Ba/sup 2+/> Mg/sup 3+/> Na/sup +/> K/sup +/> Li/sup +/ the levels of Ba/sup +2/ and K/sup +/ were found higher than permissible levels in almost all the soil samples. It was also concluded that the agricultural areas near the industrial drain which are either irrigated or not by the industrial waste water are found highly contaminated with mobile alkali metals (K, Na etc.) and higher values of percentage salinity. (author)

  11. Postoperative use of drain in thyroid lobectomy – a randomized clinical trial conducted at Civil Hospital, Karachi, Pakistan

    Directory of Open Access Journals (Sweden)

    Memon Zahid

    2012-09-01

    Full Text Available Abstract Background Thyroidectomy is a common surgical procedure, after which drains are placed routinely. This study aims to assess the benefits of placing postoperative drains, its complications and affects on postoperative stay, in thyroid lobectomy. Methodology Randomized Clinical Trial of 60 goitre patients undergoing lobectomy was conducted at Civil Hospital Karachi, during July’11-December’11. Patients were randomly assigned into drain and non drain groups. Patient demographics, labs and complications were noted. Ultrasound of neck was performed on both groups. For drain group, the amount of fluid present in the surgical bed and redivac drain was added to calculate fluid collection while in non drain group it was calculated by ultrasound of neck on first and second post-op days. Data was entered and analyzed on SPSS v16 using Independent T tests. Result The mean total drain output for 2 days in non-drain group was significantly lower 10.67 (±9.072 ml while in drain group was 30.97 (±42.812 ml (p = 0.014. The mean postoperative stay of drain group (79.2 ±15.63 hours was significantly higher, as compared to mean postoperative stay of non drain group (50.4 ±7.32 hours. Mean Visual Analogue Score (VAS for pain day 1 (6.2 ±0.997 and day 2 (4.17 ±0.95 in drain group were significantly higher compared to day 1 (2.6 ±1.163 and day 2 (1.3 ±0.877 of non drain group. From drain group, 2 patients complained of stridor, dyspnea on Day 1 which subsided by Day 2 and 1 case of voice change, with no such complains in non drain group. No patients from both groups developed seroma, wound infection or hematoma. Conclusion In uncomplicated surgeries especially for lobectomy, use of drain can be omitted.

  12. Reverse blocking characteristics and mechanisms in Schottky-drain AlGaN/GaN HEMT with a drain field plate and floating field plates

    Science.gov (United States)

    Wei, Mao; Wei-Bo, She; Cui, Yang; Jin-Feng, Zhang; Xue-Feng, Zheng; Chong, Wang; Yue, Hao

    2016-01-01

    In this paper, a novel AlGaN/GaN HEMT with a Schottky drain and a compound field plate (SD-CFP HEMT) is presented for the purpose of better reverse blocking capability. The compound field plate (CFP) consists of a drain field plate (DFP) and several floating field plates (FFPs). The physical mechanisms of the CFP to improve the reverse breakdown voltage and to modulate the distributions of channel electric field and potential are investigated by two-dimensional numerical simulations with Silvaco-ATLAS. Compared with the HEMT with a Schottky drain (SD HEMT) and the HEMT with a Schottky drain and a DFP (SD-FP HEMT), the superiorities of SD-CFP HEMT lie in the continuous improvement of the reverse breakdown voltage by increasing the number of FFPs and in the same fabrication procedure as the SD-FP HEMT. Two useful optimization laws for the SD-CFP HEMTs are found and extracted from simulation results. The relationship between the number of the FFPs and the reverse breakdown voltage as well as the FP efficiency in SD-CFP HEMTs are discussed. The results in this paper demonstrate a great potential of CFP for enhancing the reverse blocking ability in AlGaN/GaN HEMT and may be of great value and significance in the design and actual manufacture of SD-CFP HEMTs. Project supported by the National Natural Science Foundation of China (Grant Nos. 61204085, 61334002, 61306017, 61474091, 61574112, and 61574110).

  13. Effects of Drains on Pain, Comfort and Anxiety in Patients Undergone Surgery

    Directory of Open Access Journals (Sweden)

    Ummu Yildiz Findik

    2013-01-01

    Full Text Available Backround: Surgical drains negatively affect patients’ comfort, cause anxiety along with pain, as they are used to promote healing after surgery.Purpose: This study aimed to determine pain, comfort and anxiety levels of patients with drains postoperatively.Methodology: Research was performed with 192 patients undergone abdominal, neck, breast and open heart surgery and had surgical and underwater chest drains at the postoperative period. Patient Information Form, Numerical Pain Scale, General Comfort Questionnaire and Trait Anxiety Scale was used for collection of data. In evaluating the data, we used the t-test, variance and correlation analysis, mean, percentage and frequency.Results: The patients’ mean score of pain was 4.67±2.93, comfort was 2.75±0.29 and anxiety was 39.31±9.21. It was found statistically significant that the comfort level decreases as the pain level increases and that the patients undergone open heart surgery and with underwater chest drains have higher pain levels. It was found statistically significant that, comfort level in patients undergone abdominal or cardiac surgery is lower than patients undergone breast or neck surgery, and that the comfort level decreases as the duration of drains increases. The increasing state anxiety while pain increases and comfort decreases was found statistically significant.Conclusions: Surgeries and drains applied after these procedures decrease the comfort level of the patients as increases the pain level. Also, pain and discomfort increase the patients’ anxiety. Nurses who providing care to these patients are suggested to improve measures about pain and anxiety reduction for maintaining of comfort.

  14. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report.

    Science.gov (United States)

    Lai, Peng-Sheng; Lo, Chiao; Lin, Long-Wei; Lee, Po-Chu

    2010-05-21

    Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  15. Effects of trap-assisted tunneling on gate-induced drain leakage in silicon-germanium channel p-type FET for scaled supply voltages

    Science.gov (United States)

    Tiwari, Vishal A.; Divakaruni, Rama; Hook, Terence B.; Nair, Deleep R.

    2016-04-01

    Silicon-germanium is considered as an alternative channel material to silicon p-type FET (pFET) for the development of energy efficient high performance transistors for 28 nm and beyond in a high-k metal gate technology because of its lower threshold voltage and higher mobility. However, gate-induced drain leakage (GIDL) is a concern for high threshold voltage device design because of tunneling at reduced bandgap. In this work, the trap-assisted tunneling and band-to-band tunneling (BTBT) effects on GIDL is analyzed and modeled for SiGe pFETs. Experimental results and Monte Carlo simulation results reveal that the pre-halo germanium pre-amorphization implant used to contain the short channel effects contribute to GIDL at the drain sidewall in addition to GIDL due to BTBT in SiGe devices. The results are validated by comparing the experimental observations with the numerical simulation and a set of calibrated models are used to describe the GIDL mechanisms for various drain and gate bias.

  16. Greenhouse gases emission from the sewage draining rivers.

    Science.gov (United States)

    Hu, Beibei; Wang, Dongqi; Zhou, Jun; Meng, Weiqing; Li, Chongwei; Sun, Zongbin; Guo, Xin; Wang, Zhongliang

    2018-01-15

    Carbon dioxide (CO 2 ), methane (CH 4 ) and nitrous oxide (N 2 O) concentration, saturation and fluxes in rivers (Beitang drainage river, Dagu drainage rive, Duliujianhe river, Yongdingxinhe river and Nanyunhe river) of Tianjin city (Haihe watershed) were investigated during July and October in 2014, and January and April in 2015 by static headspace gas chromatography method and the two-layer model of diffusive gas exchange. The influence of environmental variables on greenhouse gases (GHGs) concentration under the disturbance of anthropogenic activities was discussed by Spearman correlative analysis and multiple stepwise regression analysis. The results showed that the concentration and fluxes of CO 2 , CH 4 and N 2 O were seasonally variable with >winter>fall>summer, spring>summer>winter>fall and summer>spring>winter>fall for concentrations and spring>summer>fall>winter, spring>summer>winter>fall and summer>spring>fall>winter for fluxes respectively. The GHGs concentration and saturation were higher in comprehensively polluted river sites and lower in lightly polluted river sites. The three GHGs emission fluxes in two sewage draining rivers of Tianjin were clearly higher than those of other rivers (natural rivers) and the spatial variation of CH 4 was more obvious than the others. CO 2 and N 2 O air-water interface emission fluxes of the sewage draining rivers in four seasons were about 1.20-2.41 times and 1.13-3.12 times of those in the natural rivers. The CH 4 emission fluxes of the sewage draining rivers were 3.09 times in fall to 10.87 times in spring of those in the natural rivers in different season. The wind speed, water temperature and air temperature were related to GHGs concentrations. Nitrate and nitrite (NO 3 - +NO 2 - -N) and ammonia (NH 4 + -N) were positively correlated with CO 2 concentration and CH 4 concentration; and dissolved oxygen (DO) concentration was negatively correlated with CH 4 concentration and N 2 O concentration. The effect of

  17. Experiments of draining and filling processes in a collapsible tube at high external pressure

    Science.gov (United States)

    Flaud, P.; Guesdon, P.; Fullana, J.-M.

    2012-02-01

    The venous circulation in the lower limb is mainly controlled by the muscular action of the calf. To study the mechanisms governing the venous draining and filling process in such a situation, an experimental setup, composed by a collapsible tube under external pressure, has been built. A valve preventing back flows is inserted at the bottom of the tube and allows to model two different configurations: physiological when the fluid flow is uni-directional and pathological when the fluid flows in both directions. Pressure and flow rate measurements are carried out at the inlet and outlet of the tube and an original optical device with three cameras is proposed to measure the instantaneous cross-sectional area. The experimental results (draining and filling with physiological or pathological valves) are confronted to a simple one-dimensional numerical model which completes the physical interpretation. One major observation is that the muscular contraction induces a fast emptying phase followed by a slow one controlled by viscous effects, and that a defect of the valve decreases, as expected, the ejected volume.

  18. RF dynamic and noise performance of Metallic Source/Drain SOI n-MOSFETs

    Science.gov (United States)

    Martin, Maria J.; Pascual, Elena; Rengel, Raúl

    2012-07-01

    This paper presents a detailed study of the RF and noise performance of n-type Schottky barrier (SB) MOSFETs with a particular focus on the influence of the Schottky barrier height (SBH) on the main dynamic and noise figures of merit. With this aim, a 2D Monte Carlo simulator including tunnelling transport across Schottky interfaces has been developed, with special care to consider quantum transmission coefficients and the influence of image charge effects at the Schottky junctions. Particular attention is paid to the microscopic transport features, including carrier mean free paths or number of scattering events along the channel for investigating the optimization of the device topology and the strategic concepts related to the noise performance of this new architecture. A more effective control of the gate electrode over drain current for low SBH (discussed in terms of internal physical quantities) is translated into an enhanced transconductance gm, cut-off frequency fT, and non-quasistatic dynamic parameters. The drain and gate intrinsic noise sources show a noteworthy degradation with the SBH reduction due to the increased current, influence of hot carriers and reduced number of phonon scatterings. However, the results evidence that this effect is counterbalanced by the extremely improved dynamic performance in terms of gm and fT. Therefore, the deterioration of the intrinsic noise performance of the SB-MOSFET has no significant impact on high-frequency noise FoMs as NFmin, Rn and Gass for low SBH and large gate overdrive conditions. The role of the SBH on Γopt, optimum noise reactance and susceptance has been also analyzed.

  19. Water and nutrient balances in a large tile-drained agricultural catchment: a distributed modeling study

    Directory of Open Access Journals (Sweden)

    H. Li

    2010-11-01

    Full Text Available This paper presents the development and implementation of a distributed model of coupled water nutrient processes, based on the representative elementary watershed (REW approach, to the Upper Sangamon River Basin, a large, tile-drained agricultural basin located in central Illinois, mid-west of USA. Comparison of model predictions with the observed hydrological and biogeochemical data, as well as regional estimates from literature studies, shows that the model is capable of capturing the dynamics of water, sediment and nutrient cycles reasonably well. The model is then used as a tool to gain insights into the physical and chemical processes underlying the inter- and intra-annual variability of water and nutrient balances. Model predictions show that about 80% of annual runoff is contributed by tile drainage, while the remainder comes from surface runoff (mainly saturation excess flow and subsurface runoff. It is also found that, at the annual scale nitrogen storage in the soil is depleted during wet years, and is supplemented during dry years. This carryover of nitrogen storage from dry year to wet year is mainly caused by the lateral loading of nitrate. Phosphorus storage, on the other hand, is not affected much by wet/dry conditions simply because the leaching of it is very minor compared to the other mechanisms taking phosphorous out of the basin, such as crop harvest. The analysis then turned to the movement of nitrate with runoff. Model results suggested that nitrate loading from hillslope into the channel is preferentially carried by tile drainage. Once in the stream it is then subject to in-stream denitrification, the significant spatio-temporal variability of which can be related to the variation of the hydrologic and hydraulic conditions across the river network.

  20. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    Directory of Open Access Journals (Sweden)

    Lin Long-Wei

    2010-05-01

    Full Text Available Abstract Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagojejunostomy anastomotic site. The drain was removed from outside of abdominal wound while observing the anastomotic site endoscopically. The patient was treated with suction via a nasogastric tube drain for 5 days, and thereafter had an uneventful recovery. Conclusions Though drain tube migration is a rare occurrence, it should be considered in patients with persistent drainage who have undergone gastric surgery.

  1. Origin of switching current transients in TIPS-pentacene based organic thin-film transistor with polymer dielectric

    Science.gov (United States)

    Singh, Subhash; Mohapatra, Y. N.

    2017-06-01

    We have investigated switch-on drain-source current transients in fully solution-processed thin film transistors based on 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-pentacene) using cross-linked poly-4-vinylphenol as a dielectric. We show that the nature of the transient (increasing or decreasing) depends on both the temperature and the amplitude of the switching pulse at the gate. The isothermal transients are analyzed spectroscopically in a time domain to extract the degree of non-exponentiality and its possible origin in trap kinetics. We propose a phenomenological model in which the exchange of electrons between interfacial ions and traps controls the nature of the drain current transients dictated by the Fermi level position. The origin of interfacial ions is attributed to the essential fabrication step of UV-ozone treatment of the dielectric prior to semiconductor deposition.

  2. Method of bilateral pleural drainage by single Blake drain after esophagectomy.

    Science.gov (United States)

    Niwa, Yukiko; Koike, Masahiko; Oya, Hisaharu; Iwata, Naoki; Kobayashi, Daisuke; Kanda, Mitsuro; Tanaka, Chie; Yamada, Suguru; Fujii, Tsutomu; Nakayama, Goro; Sugimoto, Hiroyuki; Nomoto, Shuji; Fujiwara, Michitaka; Kodera, Yasuhiro

    2015-03-01

    Clinicians often encounter left pleural effusion after esophagectomy, which sometimes necessitates thoracentesis. We have introduced a new drainage method, bilateral pleural drainage by single Blake drain (BDSD), which we have been using since April 2013. This study aims to evaluate the performance of the BDSD. The BDSD method employs a 15-F Blake drain inserted from the right thoracic cavity to the left thoracic cavity across the posterior mediastinum. The conventional drain (CD) group consisted of 50 patients with a 19-F Blake drain placed in the right thoracic cavity during the period from April 2012 to March 2013. The BDSD group consisted of 54 patients treated from April 2013 to June 2014. The amount of total drainage in the BDSD group was significantly higher than that in the CD group (P pleural effusion and left lower lobe atelectasis in the BDSD group were significantly lower than those in the CD group (P pleural effusion necessitating thoracentesis drainage in the BDSD group. Compared with the conventional method, BDSD was able to evacuate bilateral pleural effusion more effectively, and the incidences of left pleural effusion and left atelectasis were lower. This method is therefore clinically useful after esophagectomy.

  3. State waste discharge permit application, 200-E chemical drain field

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field.

  4. State waste discharge permit application, 200-E chemical drain field

    International Nuclear Information System (INIS)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field

  5. Strained Si channel NMOSFETs using a stress field with Si1-yC y source and drain stressors

    International Nuclear Information System (INIS)

    Chang, S.T.; Tasi, H.-S.; Kung, C.Y.

    2006-01-01

    The strain field in the silicon channel of a metal-oxide-semiconductor transistor with silicon-carbon alloy source and drain stressors was evaluated using the commercial process simulator FLOOPS-ISE TM . The physical origin of the strain components in the transistor channel region was explained. The magnitude and distribution of the strain components, and their dependence on device design parameters such as the spacing L G between the silicon-carbon alloy stressors, the carbon mole fraction in the stressors and stressor depth were investigated. Reducing the stressor spacing L G or increasing the carbon mole fraction in the stressors and stressor depth increases the magnitude of the vertical compressive stress and the lateral tensile stress in the portion of the N channel region where the inversion charge resides. This is beneficial for improving the electron mobility in n-channel metal-oxide-semiconductor transistors. A simple guiding principle for an optimum combination of the above-mentioned device design parameters in terms of mobility enhancement, drain current enhancement and the tradeoff consideration for junction leakage current degradation

  6. Drainage of shallow peat harvesting areas with pipe drains; Mataloituneen turvekentaen kuivatus putkisalaojilla

    Energy Technology Data Exchange (ETDEWEB)

    Klemetti, V.; Saenkiaho, K. [Vapo Oy, Jyvaeskylae (Finland); Rautiainen, O. [Ojamarkkinointi Oy, Heinola (Finland)

    1996-12-31

    This study aims to develop pipe draining technics in peat harvesting areas, which have been in active use so long time that the remaining peat layer is about one meter thick. The method should be technically and economically feasible as well as environmentally acceptable. Special attention is paid to pipe installation techniques, drain spacing and impacts on watercourses, which receive the drainage waters. After pipe installation the area is monitored by measuring pipe runoffs, water tables, moisture content of peat and quality of drain water

  7. Long-term hydrology and water quality of a drained pine plantation in North Carolina

    Science.gov (United States)

    D.M. Amatya; R.W. Skaggs

    2011-01-01

    Long-term data provide a basis for understanding natural variability, reducing uncertainty in model inputs and parameter estimation, and developing new hypotheses. This article evaluates 21 years (1988-2008) of hydrologic data and 17 years (1988-2005) of water quality data from a drained pine plantation in eastern North Carolina. The plantation age was 14 years at the...

  8. Remaining Sites Verification Package for the 100-F-46, 119-F Stack Sampling French Drain. Attachment to Waste Site Reclassification Form 2008-021

    International Nuclear Information System (INIS)

    Capron, J.M.

    2008-01-01

    The 100-F-46 french drain consisted of a 1.5 to 3 m long, vertically buried, gravel-filled pipe that was approximately 1 m in diameter. Also included in this waste site was a 5 cm cast-iron pipeline that drained condensate from the 119-F Stack Sampling Building into the 100-F-46 french drain. In accordance with this evaluation, the confirmatory sampling results support a reclassification of this site to No Action. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of confirmatory sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  9. Safety of peritoneal and pleural drain placement in pediatric stem cell transplant recipients with severe veno-occlusive disease.

    Science.gov (United States)

    Madenci, Arin L; Stetson, Alyssa; Weldon, Christopher B; Lehmann, Leslie E

    2016-08-01

    Hepatic VOD (veno-occlusive disease) is a serious complication of HSCT (hematopoietic stem cell transplantation) and has historically been associated with high mortality. This obstruction to hepatic flow often results in fluid collections in the peritoneal and pleural cavities. Catheter placement to drain ascites or pleural fluid may reduce intra-abdominal hypertension and/or improve respiratory parameters. The safety of these interventions among critically ill, immunocompromised children is unknown. Among 32 HSCT recipients (2000-2012) with severe VOD, we assessed the primary outcome of procedural complication from peritoneal drain placement. Twenty-four (75%) patients underwent peritoneal drain placement. No patient sustained visceral perforation or hemorrhage with drain placement. Overall mortality was 47% (n = 15). The procedure was not associated with increased overall mortality (p > 0.99). Eight (25%) peritoneal drains required replacement for malfunction. Of 24 patients with peritoneal drains, one (4%) patient had a positive culture from ascitic fluid. Eight (25%) patients underwent pleural drain placement. No pleural drain-related procedural complication or infection occurred. Four (50%) of the eight patients with pleural drains had de-escalation in oxygen requirement at drain removal, compared to time of placement. In this study, peritoneal and pleural drains were safe interventions for children with severe VOD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Sensitivity analysis of the agricultural policy/environmental extender (APEX) for phosphorus loads in tile-drained landscapes

    Science.gov (United States)

    Numerical modeling is an economical and feasible approach for quantifying the effects of best management practices on phosphorus (P) loadings from agricultural fields. However, tools that simulate both surface and subsurface P pathways are limited and have not been robustly evaluated in tile-drained...

  11. Effect of defect creation and migration on hump characteristics of a-InGaZnO thin film transistors under long-term drain bias stress with light illumination

    Science.gov (United States)

    Cho, Yong-Jung; Kim, Woo-Sic; Lee, Yeol-Hyeong; Park, Jeong Ki; Kim, Geon Tae; Kim, Ohyun

    2018-06-01

    We investigated the mechanism of formation of the hump that occurs in the current-voltage I-V characteristics of amorphous InGaZnO (a-IGZO) thin film transistors (TFTs) that are exposed to long-term drain bias stress under illumination. Transfer characteristics showed two-stage degradation under the stress. At the beginning of the stress, the I-V characteristics shifted in the negative direction with a degradation of subthreshold slope, but the hump phenomenon developed over time in the I-V characteristics. The development of the hump was related to creation of defects, especially ionized oxygen vacancies which act as shallow donor-like states near the conduction-band minimum in a-IGZO. To further investigate the hump phenomenon we measured a capacitance-voltage C-V curve and performed two-dimensional device simulation. Stretched-out C-V for the gate-to-drain capacitance and simulated electric field distribution which exhibited large electric field near the drain side of TFT indicated that VO2+ were generated near the drain side of TFT, but the hump was not induced when VO2+ only existed near the drain side. Therefore, the degradation behavior under DBITS occurred because VO2+ were created near the drain side, then were migrated to the source side of the TFT.

  12. 76 FR 62605 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Science.gov (United States)

    2011-10-11

    ... the VGB Act defines an ``unblockable drain'' as ``a drain of any size and shape that a human body... intentions. They claim that for this reason, backup systems are necessary, and a swimming pool or spa with a... of an ``unblockable drain,'' at 16 CFR 1450.2(b) and believe it was in error. Regardless of the size...

  13. Agustin de Betancourt’s Wind Machine for Draining Marshy Ground: Approach to Its Geometric Modeling with Autodesk Inventor Professional

    Directory of Open Access Journals (Sweden)

    José Ignacio Rojas-Sola

    2016-12-01

    Full Text Available The present study shows the process followed in making the three-dimensional model and geometric documentation of a historical invention of the renowned Spanish engineer Agustin de Betancourt y Molina, which forms part of his rich legacy. Specifically, this was a wind machine for draining marshy ground, designed in 1789. The present research relies on the computer-aided design (CAD techniques using Autodesk Inventor Professional software, based on the scant information provided by the only two drawings of the machine, making it necessary to propose a number of dimensional and geometric hypotheses as well as a series of movement restrictions (degrees of freedom, to arrive at a consistent design. The results offer a functional design for this historic invention.

  14. Interaction of the Bored Sand and Gravel Drain Pile with the Surrounding Compacted Loam Soil and Foundation Raft Taking into Account Rheological Properties of the Loam Soil and Non-Linear Properties of the Drain Pile

    Science.gov (United States)

    Ter-Martirosyan, Z. G.; Ter-Martirosyan, A. Z.; Anzhelo, G. O.; Buslov, A. S.

    2018-01-01

    The task of the interaction of the sand and gravel drain pile with the surrounding loam soil after its preliminary deep compaction and formation of the composite ground cylinder from the drain pile and surrounding compacted loam soil (cells) is considered in the article. It is seen that the subsidence and carrying capacity of such cell considerably depends on physical and mechanical properties of the compacted drain piles and surrounding loam soil as well as their diameter and intercellular distance. The strain-stress state of the cell is considered not taking into account its component elements, but taking into account linear and elastic-plastic properties of the drain pile and creep flow of the surrounding loam soil. It is stated that depending on these properties the distribution and redistribution of the load on a cell takes place from the foundation raft between the drain pile and surrounding soil. Based on the results of task solving the formulas and charts are given demonstrating the ratio of the load between the drain pile and surrounding loam soil in time.

  15. Small drains, big problems: the impact of dry weather runoff on shoreline water quality at enclosed beaches.

    Science.gov (United States)

    Rippy, Megan A; Stein, Robert; Sanders, Brett F; Davis, Kristen; McLaughlin, Karen; Skinner, John F; Kappeler, John; Grant, Stanley B

    2014-12-16

    Enclosed beaches along urban coastlines are frequent hot spots of fecal indicator bacteria (FIB) pollution. In this paper we present field measurements and modeling studies aimed at evaluating the impact of small storm drains on FIB pollution at enclosed beaches in Newport Bay, the second largest tidal embayment in Southern California. Our results suggest that small drains have a disproportionate impact on enclosed beach water quality for five reasons: (1) dry weather surface flows (primarily from overirrigation of lawns and ornamental plants) harbor FIB at concentrations exceeding recreational water quality criteria; (2) small drains can trap dry weather runoff during high tide, and then release it in a bolus during the falling tide when drainpipe outlets are exposed; (3) nearshore turbulence is low (turbulent diffusivities approximately 10(-3) m(2) s(-1)), limiting dilution of FIB and other runoff-associated pollutants once they enter the bay; (4) once in the bay, runoff can form buoyant plumes that further limit vertical mixing and dilution; and (5) local winds can force buoyant runoff plumes back against the shoreline, where water depth is minimal and human contact likely. Outdoor water conservation and urban retrofits that minimize the volume of dry and wet weather runoff entering the local storm drain system may be the best option for improving beach water quality in Newport Bay and other urban-impacted enclosed beaches.

  16. Characterizing subsurface water flow to artificial drain lines using fiber-optic distributed temperature sensing

    Science.gov (United States)

    Shults, D.; Brooks, E. S.; Heinse, R.; Keller, C. K.

    2017-12-01

    Over the last several years growers have experienced increasingly wet spring conditions in the Palouse Region located in North Idaho, Eastern Washington and Eastern Oregon. As a result more artificial drain lines are being installed so growers can access their fields earlier in the growing season. Additionally there has been increasing adoption of no-tillage practices among growers in order minimize erosion and runoff in the region. There is a growing body of evidence that suggests long-term no-tillage may lead to the establishment of large macropore networks through increased earthworm activity and the preservation of root channels. These macropore networks, in conjunctions with the presence of artificial drains lines, may create connected preferential flow paths from agricultural fields to receiving streams. This connectivity of flow paths from agricultural fields to receiving water bodies may increase the loading of nutrients and agricultural chemicals as some flow paths may largely bypass soil matrix interaction where materials can be sequestered. Our primary objective for this study was to characterize subsurface flow to two artificial drain lines, one under conventional tillage and the other under no-tillage, using distributed temperature sensing (DTS) technology. During the study (November 2016-April 2017) the near surface soil-water temperature was consistently colder than that of deeper depths. Temperature was thus used as a tracer as snow melt and soil-water moved from the near surface to the drain lines during snowmelt and precipitation events. The spatial and temporal variability of the temperature along the artificial drain line under no-tillage practices was found to be greater than that of the conventional tilled field. It is hypothesized that preferential flow paths are responsible for the increased variability of temperature seen in the drain line under long term no-till management. The temperature along the conventional till drain line showed a

  17. Verifiable metamodels for nitrate losses to drains and groundwater in the Corn Belt, USA

    Science.gov (United States)

    Nolan, Bernard T.; Malone, Robert W.; Gronberg, Jo Ann M.; Thorp, K.R.; Ma, Liwang

    2012-01-01

    Nitrate leaching in the unsaturated zone poses a risk to groundwater, whereas nitrate in tile drainage is conveyed directly to streams. We developed metamodels (MMs) consisting of artificial neural networks to simplify and upscale mechanistic fate and transport models for prediction of nitrate losses by drains and leaching in the Corn Belt, USA. The two final MMs predicted nitrate concentration and flux, respectively, in the shallow subsurface. Because each MM considered both tile drainage and leaching, they represent an integrated approach to vulnerability assessment. The MMs used readily available data comprising farm fertilizer nitrogen (N), weather data, and soil properties as inputs; therefore, they were well suited for regional extrapolation. The MMs effectively related the outputs of the underlying mechanistic model (Root Zone Water Quality Model) to the inputs (R2 = 0.986 for the nitrate concentration MM). Predicted nitrate concentration was compared with measured nitrate in 38 samples of recently recharged groundwater, yielding a Pearson’s r of 0.466 (p = 0.003). Predicted nitrate generally was higher than that measured in groundwater, possibly as a result of the time-lag for modern recharge to reach well screens, denitrification in groundwater, or interception of recharge by tile drains. In a qualitative comparison, predicted nitrate concentration also compared favorably with results from a previous regression model that predicted total N in streams.

  18. Consequences assessment for fuel channel failure with consequential moderator drain

    International Nuclear Information System (INIS)

    Wahba, N.N.; Bayoumi, M.H.

    2002-01-01

    This paper documents the consequences of spontaneous pressure tube/consequential calandria tube rupture followed by the ejection of end fittings (as a result of guillotine failure of pressure tube) leading to the drain of the moderator. The event is postulated to occur in conjunction with an independent failure of Emergency Coolant Injection System (ECIS). The results of the detailed consequence assessments are used to propose a course of action to mitigate the consequences of such an event. A methodology based on a lumped-parameter model was developed to assess the consequences of the postulated event. (author)

  19. Photoionization spectroscopy of deep defects responsible for current collapse in nitride-based field effect transistors

    International Nuclear Information System (INIS)

    Klein, P B; Binari, S C

    2003-01-01

    This review is concerned with the characterization and identification of the deep centres that cause current collapse in nitride-based field effect transistors. Photoionization spectroscopy is an optical technique that has been developed to probe the characteristics of these defects. Measured spectral dependences provide information on trap depth, lattice coupling and on the location of the defects in the device structure. The spectrum of an individual trap may also be regarded as a 'fingerprint' of the defect, allowing the trap to be followed in response to the variation of external parameters. The basis for these measurements is derived through a modelling procedure that accounts quantitatively for the light-induced drain current increase in the collapsed device. Applying the model to fit the measured variation of drain current increase with light illumination provides an estimate of the concentrations and photoionization cross-sections of the deep defects. The results of photoionization studies of GaN metal-semiconductor field effect transistors and AlGaN/GaN high electron mobility transistors (HEMTs) grown by metal-organic chemical vapour deposition (MOCVD) are presented and the conclusions regarding the nature of the deep traps responsible are discussed. Finally, recent photoionization studies of current collapse induced by short-term (several hours) bias stress in AlGaN/GaN HEMTs are described and analysed for devices grown by both MOCVD and molecular beam epitaxy. (topical review)

  20. Development of Charge Drain Coatings: Final CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Elam, Jeffrey W. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-17

    The primary goal of this CRADA project was to develop and optimize tunable resistive coatings prepared by atomic layer deposition (ALD) for use as charge-drain coatings on the KLA-Tencor digital pattern generators (DPGs).

  1. Roundtable. Strategies to discourage brain drain.

    Science.gov (United States)

    Kupfer, Linda; Hofman, Karen; Jarawan, Raya; McDermott, Jeanne; Bridbord, Ken

    2004-08-01

    Building health research expertise in developing countries often requires personnel to receive training beyond national borders. For research funding agencies that sponsor this type of training, a major goal is to ensure that trainees return to their country of origin: attaining this objective requires the use of proactive strategies. The strategies described were developed under the extramural acquired immunodeficiency syndrome (AIDS) International Training and Research Program (AITRP) funded by the Fogarty International Center (FIC) at the National Institutes of Health, United States. This programme supports universities in the United States that provide research training to scientists from developing countries to enable them to address the global epidemic of human immunodeficiency virus (HIV)/AIDS and the related tuberculosis (TB) epidemic. This paper describes the strategies employed to discourage brain drain by the principle investigators (PIs) of five of the longest-funded AITRPs (funded for 15 years). Long-term trainees in these programmes spent from 11 to 96 months (an average of 26 months) studying. Using scientific, political and economic strategies that address brain drain issues, PIs working in AITRPs have attained an average rate of return home for their trainees of 80%.

  2. Calibration and Validation of the Precision Nitrogen Management Tool for Artificially Drained Fields Under Maize

    Science.gov (United States)

    Marjerison, R.; Hutson, J.; Melkonian, J.; van Es, H.; Sela, S.

    2015-12-01

    Organic and inorganic fertilizer additions to agricultural fields can lead to soil nitrogen (N) levels in excess of those required for optimal crop growth. The primary loss pathways for this excess N are leaching and denitrification. Nitrate leaching from agricultural sources contributes to the formation of hypoxic zones in critical estuarine systems including the Chesapeake Bay and Gulf of Mexico. Denitrification can lead to the production of nitrous oxide (N2O), a potent greenhouse gas. Agricultural practices such as controlling the timing and location of fertilizer application can help reduce these losses. The Precision Nitrogen Management (PNM) model was developed to simulate water transport, nitrogen transformations and transport, and crop growth and nutrient uptake from agricultural fields. The PNM model allows for the prediction of N losses under a variety of crop and management scenarios. Recent improvements to the model include the option to simulate artificially drained fields. The model performs well in simulating drainage and nitrate leaching when compared to measured data from field studies in artificially drained soils in New York and Minnesota. A simulated N budget was compared to available data. The improved model will be used to assess different management options for reducing N losses in maize production under different climate projections for key maize production locations/systems in the U.S.

  3. Investigation and statistical modeling of InAs-based double gate tunnel FETs for RF performance enhancement

    Science.gov (United States)

    Poorvasha, S.; Lakshmi, B.

    2018-05-01

    In this paper, RF performance analysis of InAs-based double gate (DG) tunnel field effect transistors (TFETs) is investigated in both qualitative and quantitative fashion. This investigation is carried out by varying the geometrical and doping parameters of TFETs to extract various RF parameters, unity gain cut-off frequency (f t), maximum oscillation frequency (f max), intrinsic gain and admittance (Y) parameters. An asymmetric gate oxide is introduced in the gate-drain overlap and compared with that of DG TFETs. Higher ON-current (I ON) of about 0.2 mA and less leakage current (I OFF) of 29 fA is achieved for DG TFET with gate-drain overlap. Due to increase in transconductance (g m), higher f t and intrinsic gain is attained for DG TFET with gate-drain overlap. Higher f max of 985 GHz is obtained for drain doping of 5 × 1017 cm‑3 because of the reduced gate-drain capacitance (C gd) with DG TFET with gate-drain overlap. In terms of Y-parameters, gate oxide thickness variation offers better performance due to the reduced values of C gd. A second order numerical polynomial model is generated for all the RF responses as a function of geometrical and doping parameters. The simulation results are compared with this numerical model where the predicted values match with the simulated values. Project supported by the Department of Science and Technology, Government of India under SERB Scheme (No. SERB/F/2660).

  4. Postoperative intraabdominal fluid collections : a modified percutaneous drainage method using a surgical drain track

    International Nuclear Information System (INIS)

    Lee, Deok Hee; Kim, Gab Choul; Hwang, Jae Cheol; Yoon, Hyun Ki; Song, Ho Young; Sung, Kyu Bo

    2000-01-01

    In the management of postoperative fluid collection, the conventional percutaneous drainage method can be employed. Because of abdominal incisions and various types of surgical drains and/or T-tubes, the application of this method is not always easy, however. We inserted a drainage catheter through a pre-existing percutaneous track formed by a surgical drain located adjacent to the site of abnormal fluid collection. There was no need to remove the drain nor make an additional puncture in the abdominal wall. A dilator was inserted along the drain, and a guide wire was used to negotiate its intraperitoneal track and reach the accumulated fluid. The procedure was simple and safe. We briefly describe our experience of this modified percutaneous drainage technique, as used in three cases involving postoperative fluid collection. (author)

  5. Current collapse imaging of Schottky gate AlGaN/GaN high electron mobility transistors by electric field-induced optical second-harmonic generation measurement

    International Nuclear Information System (INIS)

    Katsuno, Takashi; Ishikawa, Tsuyoshi; Ueda, Hiroyuki; Uesugi, Tsutomu; Manaka, Takaaki; Iwamoto, Mitsumasa

    2014-01-01

    Two-dimensional current collapse imaging of a Schottky gate AlGaN/GaN high electron mobility transistor device was achieved by optical electric field-induced second-harmonic generation (EFISHG) measurements. EFISHG measurements can detect the electric field produced by carriers trapped in the on-state of the device, which leads to current collapse. Immediately after (e.g., 1, 100, or 800 μs) the completion of drain-stress voltage (200 V) in the off-state, the second-harmonic (SH) signals appeared within 2 μm from the gate edge on the drain electrode. The SH signal intensity became weak with time, which suggests that the trapped carriers are emitted from the trap sites. The SH signal location supports the well-known virtual gate model for current collapse.

  6. The routine use of post-operative drains in thyroid surgery: an outdated concept.

    LENUS (Irish Health Repository)

    Prichard, R S

    2010-01-01

    The use of surgical drains in patients undergoing thyroid surgery is standard surgical teaching. Life-threatening complications, arising from post-operative haematomas, mandates their utilization. There is increasing evidence to suggest that this is an outdated practice. This paper determines whether thyroid surgery can be safely performed without the routine use of drains. A retrospective review of patients undergoing thyroid surgery, over a three year period was performed and post-operative complications documented. One hundred and four thyroidectomies were performed. 63 (60.6%) patients had a partial thyroidectomy, 27 (25.9%) had a total thyroidectomy and 14 (13.5%) had a sub-total thyroidectomy. Suction drains were not inserted in any patient. A cervical haematoma did not develop in any patient in this series and no patient required re-operation. There is no evidence to suggest the routine use of surgical drains following uncomplicated thyroid surgery reduces the rate of haematoma formation or re-operation rates and indeed is now unwarranted.

  7. Preliminary design studies of the draining tanks for the Molten Salt Fast Reactor

    International Nuclear Information System (INIS)

    Merle-Lucotte, E.; Allibert, M.; Heuer, D.; Brovchenko, M.; Laureau, A.; Ghetta, V.; Rubiolo, P.

    2014-01-01

    reactor called the Molten Salt Fast Reactor (MSFR). The reference MSFR design is a 3000 MWth reactor with a total fuel salt volume of 18 m3, operated at a mean fuel temperature of 750 deg. C. The first confinement barrier of the reactor includes a salt draining system. In case of a planned reactor shut down or in case of accidents leading to an excessive increase of the temperature in the fuel circuit, the fuel configuration may be changed passively by gravitational draining of the fuel salt in dedicated draining tank located under the reactor and designed to provide adequate reactivity margins while insuring a passive cooling of the fuel salt to extract the residual heat from the short to the long term. The present preliminary assessment of this sub-critical draining system has been performed to identify the physical constraints and to give some orders of magnitude of characteristic time periods (authors)

  8. Retention of Ag-specific memory CD4+ T cells in the draining lymph node indicates lymphoid tissue resident memory populations.

    Science.gov (United States)

    Marriott, Clare L; Dutton, Emma E; Tomura, Michio; Withers, David R

    2017-05-01

    Several different memory T-cell populations have now been described based upon surface receptor expression and migratory capabilities. Here we have assessed murine endogenous memory CD4 + T cells generated within a draining lymph node and their subsequent migration to other secondary lymphoid tissues. Having established a model response targeting a specific peripheral lymph node, we temporally labelled all the cells within draining lymph node using photoconversion. Tracking of photoconverted and non-photoconverted Ag-specific CD4 + T cells revealed the rapid establishment of a circulating memory population in all lymph nodes within days of immunisation. Strikingly, a resident memory CD4 + T cell population became established in the draining lymph node and persisted for several months in the absence of detectable migration to other lymphoid tissue. These cells most closely resembled effector memory T cells, usually associated with circulation through non-lymphoid tissue, but here, these cells were retained in the draining lymph node. These data indicate that lymphoid tissue resident memory CD4 + T-cell populations are generated in peripheral lymph nodes following immunisation. © 2017 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report

    OpenAIRE

    Lin Long-Wei; Lo Chiao; Lai Peng-Sheng; Lee Po-Chu

    2010-01-01

    Abstract Background Intraluminal migration of a drain through an anastomotic site is a rare complication of gastric surgery. Case Presentation We herein report the intraluminal migration of a drain placed after a lower esophagectomy and total gastrectomy with Roux-en-Y anastomosis for gastric small cell carcinoma. Persistent drainage was noted 1 month after surgery, and radiographic studies were consistent with drain tube migration. Endoscopy revealed the drain had migrated into the esophagoj...

  10. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    OpenAIRE

    Ayhan GENCLER

    2009-01-01

    Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems tha...

  11. Nitrate concentration-drainage flow (C-Q) relationship for a drained agricultural field in Eastern North Carolina Plain

    Science.gov (United States)

    Liu, W.; Youssef, M.; Birgand, F.; Chescheir, G. M.; Maxwell, B.; Tian, S.

    2017-12-01

    Agricultural drainage is a practice used to artificially enhance drainage characteristics of naturally poorly drained soils via subsurface drain tubing or open-ditch systems. Approximately 25% of the U.S. agricultural land requires improved drainage for economic crop production. However, drainage increases the transport of dissolved agricultural chemicals, particularly nitrates to downstream surface waters. Nutrient export from artificially drained agricultural landscapes has been identified as the leading source of elevated nutrient levels in major surface water bodies in the U.S. Controlled drainage has long been practiced to reduce nitrogen export from agricultural fields to downstream receiving waters. It has been hypothesized that controlled drainage reduces nitrogen losses by promoting denitrification, reducing drainage outflow from the field, and increasing plant uptake. The documented performance of the practice was widely variable as it depends on several site-specific factors. The goal of this research was to utilize high frequency measurements to investigate the effect of agricultural drainage and related management practices on nitrate fate and transport for an artificially drained agricultural field in eastern North Carolina. We deployed a field spectrophotometer to measure nitrate concentration every 45 minutes and measured drainage flow rate using a V-notch weir every 15 minutes. Furthermore, we measured groundwater level, precipitation, irrigation amount, temperature to characterize antecedent conditions for each event. Nitrate concentration-drainage flow (C-Q) relationships generated from the high frequency measurements illustrated anti-clockwise hysteresis loops and nitrate flushing mechanism in response to most precipitation and irrigation events. Statistical evaluation will be carried out for the C-Q relationships. The results of our analysis, combined with numerical modeling, will provide a better understanding of hydrological and

  12. Carbon nanotube feedback-gate field-effect transistor: suppressing current leakage and increasing on/off ratio.

    Science.gov (United States)

    Qiu, Chenguang; Zhang, Zhiyong; Zhong, Donglai; Si, Jia; Yang, Yingjun; Peng, Lian-Mao

    2015-01-27

    Field-effect transistors (FETs) based on moderate or large diameter carbon nanotubes (CNTs) usually suffer from ambipolar behavior, large off-state current and small current on/off ratio, which are highly undesirable for digital electronics. To overcome these problems, a feedback-gate (FBG) FET structure is designed and tested. This FBG FET differs from normal top-gate FET by an extra feedback-gate, which is connected directly to the drain electrode of the FET. It is demonstrated that a FBG FET based on a semiconducting CNT with a diameter of 1.5 nm may exhibit low off-state current of about 1 × 10(-13) A, high current on/off ratio of larger than 1 × 10(8), negligible drain-induced off-state leakage current, and good subthreshold swing of 75 mV/DEC even at large source-drain bias and room temperature. The FBG structure is promising for CNT FETs to meet the standard for low-static-power logic electronics applications, and could also be utilized for building FETs using other small band gap semiconductors to suppress leakage current.

  13. Evaluation of the necessity for chest drain placement following thoracoscopic wedge resection.

    Science.gov (United States)

    Lu, Ting-Yu; Chen, Jian-Xun; Chen, Pin-Ru; Lin, Yu-Sen; Chen, Chien-Kuang; Kao, Pei-Yu; Huang, Tzu-Ming; Fang, Hsin-Yuan

    2017-05-01

    To evaluate the outcomes of patients who underwent thoracoscopic wedge resection without chest drain placement. The subjects of this retrospective study were 89 patients, who underwent thoracoscopic wedge resection at our hospital between January, 2013 and July, 2015. A total of 45 patients whose underlying condition did not meet the following criteria were assigned to the "chest drain placement group" (group A): peripheral lesions, healthy lung parenchyma, no intraoperative air leaks, hemorrhage or effusion accumulation, and no pleural adhesion. The other 44 patients whose underlying condition met the criteria were assigned to the "no chest drain placement group" (group B). Patient characteristics, specimen data, and postoperative conditions were analyzed and compared between the groups. Group A patients had poorer forced expiratory volume in one second (FEV1) values, less normal spirometric results, significantly higher resected lung volume, a greater maximum tumor-pleura distance, and a larger maximum tumor size. They also had a longer postoperative hospital stay. There was no difference between the two groups in postoperative complications. Avoiding chest drain placement after a thoracoscopic wedge resection appears to be safe and beneficial for patients who have small peripheral lesions and healthy lung parenchyma.

  14. Drain-induced barrier lowering effect for short channel dual material gate 4H silicon carbide metal—semiconductor field-effect transistor

    Science.gov (United States)

    Zhang, Xian-Jun; Yang, Yin-Tang; Duan, Bao-Xing; Chai, Chang-Chun; Song, Kun; Chen, Bin

    2012-09-01

    Sub-threshold characteristics of the dual material gate 4H-SiC MESFET (DMGFET) are investigated and the analytical models to describe the drain-induced barrier lowering (DIBL) effect are derived by solving one- and two-dimensional Poisson's equations. Using these models, we calculate the bottom potential of the channel and the threshold voltage shift, which characterize the drain-induced barrier lowering (DIBL) effect. The calculated results reveal that the dual material gate (DMG) structure alleviates the deterioration of the threshold voltage and thus suppresses the DIBL effect due to the introduced step function, which originates from the work function difference of the two gate materials when compared with the conventional single material gate metal—semiconductor field-effect transistor (SMGFET).

  15. Drain-induced barrier lowering effect for short channel dual material gate 4H silicon carbide metal—semiconductor field-effect transistor

    International Nuclear Information System (INIS)

    Zhang Xian-Jun; Yang Yin-Tang; Duan Bao-Xing; Chai Chang-Chun; Song Kun; Chen Bin

    2012-01-01

    Sub-threshold characteristics of the dual material gate 4H-SiC MESFET (DMGFET) are investigated and the analytical models to describe the drain-induced barrier lowering (DIBL) effect are derived by solving one- and two-dimensional Poisson's equations. Using these models, we calculate the bottom potential of the channel and the threshold voltage shift, which characterize the drain-induced barrier lowering (DIBL) effect. The calculated results reveal that the dual material gate (DMG) structure alleviates the deterioration of the threshold voltage and thus suppresses the DIBL effect due to the introduced step function, which originates from the work function difference of the two gate materials when compared with the conventional single material gate metal—semiconductor field-effect transistor (SMGFET)

  16. Outcome in Chronic Subdural Hematoma After Subdural vs. Subgaleal Drain

    International Nuclear Information System (INIS)

    Ishfaq, A.

    2017-01-01

    Objective: To compare the outcome after surgery for chronic subdural hematoma when the drain is placed in subdural space or subgaleal space. Study Design: Quasi experimental study. Place and Duration of Study: Combined Military Hospital, Lahore, from July 2015 to June 2016. Methodology: Patients with chronic subdural hematoma of both genders and age, ranging between 55 to 85 years, were included. Patients on antiplatelet/anticoagulant therapy and acute on chronic subdural hematoma were excluded. Patients were divided in two equal groups each depending on whether drain was placed in subgaleal space (Group 1), and subdual space (Group 2), (n=31 patients each). Patients were positioned flat in bed after surgery. Clinical and radiological parameters and clinical outcome were compared between the two groups. Statistical test with significance of p <0.05 was utilized using Statistical Package of Social Sciences (SPSS version 17). Results: Median age of the 62 patients was 72 +-12.5 years. Headache was the most common symptom reported in both groups, (n=47,75.8%) patients. Median thickness of hematoma was 15 +-6.5 mm. Patients with subdural drain placement had more complications such as pneumocephalus 11 (35.4%) vs. 6 (19.3%), and intracerebral hemorrhage 4 (12.9%) vs. 2 (6.4%). Clinical outcome was good in both groups 27 (87%) in Group 1 and 28 (90%) in Group 2. Conclusion: Patients of both groups had good outcome after surgery. Complications like pneumocephalus and intracerebral hemorrhage were more common in subdural location of drain, though not reaching statistically significance level to favor one technique over another. (author)

  17. Breakthrough of two pesticides into tile drain and shallow groundwater: comparison of tile drain reaction and soil profiles within a field scale irrigation experiment

    Science.gov (United States)

    Klaus, Julian; Zehe, Erwin; Elsner, Martin; Palm, Juliane; Schneider, Dorothee; Schröder, Boris; Steinbeiss, Sibylle; West, Stephanie

    2010-05-01

    Preferential flow in macropores is a key process which strongly affects infiltration and may cause rapid transport of pesticides into depths of 80 to 150 cm. At these depths they experience a much slower degradation, may leach into shallow groundwater or enter a tile-drain and are transported into surface water bodies. Therefore, preferential transport might be an environmental problem, if the topsoil is bypassed, which has been originally thought to act as a filter to protect the subsoil and shallow groundwater. To investigate the behaviour of two pesticides with different chemical characteristics and to compare their transport behaviour in soil and into the tile drain an irrigation experiment was performed on a 400 m² field site. The experimental plot is located in the Weiherbach valley, south-west Germany, which basic geology consists of Loess and Keuper layers, the soil at the test site is a gleyic Colluvisol. The distance of the irrigation site to the Weiherbach brook is approximately 12 m, the field is drained with a tile-drain in about 1.2 m depth and shows discharge over the entire year. Three hours before the irrigation started, the farmer applied a pesticide solution consisting of Isoproturon (80 g) and Flufenacet (20 g) (IPU and FLU) according to conventional agricultural practice on the field plot. The irrigation took place in three time blocks (80 min, 60 min, 80 min) with in total 33.6 mm of precipitation. During the first block 1600 g of Bromide were mixed in the irrigation water. The drainage outlet was instrumented with a pressure probe. About 50 water samples ware taken during the experimental day, and several samples more the days after the experiment. They were analysed for the pesticides, bromide and water isotopes. In the two days after the experiment three soil profiles were excavated and soil samples were taken on a 10x10 cm² scheme. One week after the experiment two additional profiles were excavated. The soil was analysed for IPU, FLU

  18. Risk assessment of K Basin twelve-inch and four-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-06-23

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rate which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. Five four-inch drain valves are located in the north and south loadout pits (NLOP and SLOP), the weasel pit, the technical viewing pit, and the discharge chute pit. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations indicate that only the valve's bonnet and stem are exposed above the basin concrete floor for the twelve-inch drain valve and that much less of the valve's bonnet and stem are exposed above the basin concrete floor for the five four-inch drain valves. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this analysis are to: (1) evaluate the likelihood of damaging the three twelve-inch drain valves located along the north wall of the main basin and the five four-inch drain valves located in the pits from a seismic initiating event, and (2) determine the likelihood of exceeding a specific consequence (initial leak rate) from a damaged valve. The analysis process is a risk-based uncertainty analysis where each variable is modeled using available information and engineering judgement. The uncertainty associated with each variable is represented by a probability distribution (probability density function). Uncertainty exists because of the inherent

  19. Replacement of the drain system of secondary circuit at Monju

    International Nuclear Information System (INIS)

    Itoh, Kenji; Onuki, Koji; Tomobe, Katsuma; Taniyama, Sadami

    2003-01-01

    Monju is as a Japan's prototype fast breeder reactor cooled by liquid sodium. In the course of power buildup tests, the sodium leakage accident broke out on 8th December 1995. Though Monju has been already equipped with countermeasure systems against the sodium leakage accident, some additional improvements will be taken in order to reduce the damage by the leaked sodium when another leakage accident should recur. The most characteristic work is the drain system modification that leads to shorten the drain time and to reduce the quantity of leaked sodium in the event of sodium leakage. (author)

  20. Reverse brain drain in South Korea: state-led model.

    Science.gov (United States)

    Yoon, B L

    1992-01-01

    Korea's reverse brain drain (RBD) has been an organized government effort, rather than a spontaneous social phenomenon, in that various policies and the political support of President Park, Chung-Hee were instrumental in laying the groundwork for its success. Particular features of Korea's RBD policies are the creation of a conducive domestic environment (i.e., government-sponsored strategic R & D institution-building, legal, and administrative reforms), and importantly, the empowerment of returnees (via, i.e., exceptionally good maternal benefits, guarantees of research autonomy). President Park played the cardinal role in empowering repatriates at the expense of his own civil bureaucracy, and his capacity for such patronage derived from Korea's bureaucratic-authoritarian political system. Returning scientists and engineers directly benefitted from this political system as well as Park's personal guardianship. For Park, empowerment of returning "brains" was necessary to accomplish his national industrialization plan, thereby enhancing his political legitimacy in domestic politics. An alliance with the R & D cadre was functionally necessary to successfully consolidate strong presidential power, and politically nonthreatening due to the particular form of "pact of domination" in Korea's power structure. RBD in Korea will continue in the near future given Korea's drive for high technology, and the remarkable expansion of local industrial and educational sectors. Korea's future RBD, however, needs to pay closer attention to the following 4 problems: research autonomy; equality issues; skill-based repatriation of technicians and engineers rather than Ph.Ds; and subsidies to small and medium industry for RBD.

  1. QUALIFIED VERSION OF MIGRATION: BRAIN DRAIN

    OpenAIRE

    Gencler, Ayhan

    2009-01-01

    Though globalization suggests an international exchange of people besides goods and capital, developed countries often tended to put forward some restrictions on the migration of workers from developed countries. However, there has been an increase in skilled international migration especially during the last two decades. Skilled international migration or brain drain points out the emigration of educated and highly skilled workers. It seems that, in general, developing or underdeveloped...

  2. Analytical Modeling of Triple-Metal Hetero-Dielectric DG SON TFET

    Science.gov (United States)

    Mahajan, Aman; Dash, Dinesh Kumar; Banerjee, Pritha; Sarkar, Subir Kumar

    2018-02-01

    In this paper, a 2-D analytical model of triple-metal hetero-dielectric DG TFET is presented by combining the concepts of triple material gate engineering and hetero-dielectric engineering. Three metals with different work functions are used as both front- and back gate electrodes to modulate the barrier at source/channel and channel/drain interface. In addition to this, front gate dielectric consists of high-K HfO2 at source end and low-K SiO2 at drain side, whereas back gate dielectric is replaced by air to further improve the ON current of the device. Surface potential and electric field of the proposed device are formulated solving 2-D Poisson's equation and Young's approximation. Based on this electric field expression, tunneling current is obtained by using Kane's model. Several device parameters are varied to examine the behavior of the proposed device. The analytical model is validated with TCAD simulation results for proving the accuracy of our proposed model.

  3. The catastrophic dieback of Typha domingensis in a drained and restored East Mediterranean wetland: re-examining proposed models

    Directory of Open Access Journals (Sweden)

    R. Simhayov

    2012-01-01

    Full Text Available We experimentally tested two geochemical models which have been proposed as potential mechanisms leading to the catastrophic dieback of Typha domingensis in constructed Lake Agmon within the drained Hula peatland, northern Israel. An elaborate lysimeter station simulating the conditions imposed by sulphide toxicity and P deficiency models was used to test them experimentally. Rhizosphere pH and redox potential were monitored in situ in real time throughout the summers of 2007 and 2008. A comparative study of redox-reduction simulation was coupled with periodic sampling and analysis of sulphide and other reducing species. N and P were determined in the plant tissues to compute the N:P nutrient limitation index and evaluate nutrient deficiencies. The sulphide toxicity model was not accepted as a viable mechanism because Typha domingensis stands did not show any signs of stress, even when growing in rhizosphere with a sulphide concentration three times that during the actual dieback in 1996. The P limitation model was not supported by the N:P index, which indicated N (16 limitation. Since Typha has now returned and is thriving in Lake Agmon and adjacent drainage canals, we suggest a self-thinning mechanism followed by normal succession of macrophytes in this relatively young constructed wetland as the most logical mechanism to explain the observed dieback.

  4. The use of Jackson-Pratt silicone flat drains as prolonged pleural catheters for the management of pleural effusions

    OpenAIRE

    Demirhan, Ozkan; Kasapoglu, Tugce; Ece, Ferah; Toker, Alper

    2013-01-01

    Introduction: Imbalance between secretion and absorbtion of pleural fluid results in pleural effusion. Emergence of pleural effusion ipsilateral or contralateral to the side drained previously is named recurrent effusion. There is currently no standart approach for the management of recurrent pleural effusions. Materials and methods: Eighteen patients, treated between 2011 and 2012 for recurrent pleural effusions due to various etiologies, not considered for surgical or other treatments, ...

  5. Health workforce imbalances in times of globalization: brain drain or professional mobility?

    Science.gov (United States)

    Marchal, Bruno; Kegels, Guy

    2003-01-01

    The health workforce is of strategic importance to the performance of national health systems as well as of international disease control initiatives. The brain drain from rural to urban areas, and from developing to industrialized countries is a long-standing phenomenon in the health professions but has in recent years taken extreme proportions, particularly in Africa. Adopting the wider perspective of health workforce balances, this paper presents an analysis of the underlying mechanisms of health professional migration and possible strategies to reduce its negative impact on health services. The opening up of international borders for goods and labour, a key strategy in the current liberal global economy, is accompanied by a linguistic shift from 'human capital flight' and 'brain drain' to 'professional mobility' or 'brain circulation'. In reality, this mobility is very asymmetrical, to the detriment of less developed countries, which lose not only much-needed human resources, but also considerable investments in education and fiscal income. It is argued that low professional satisfaction and the decreasing social valuation of the health professionals are important determinants of the decreasing attraction of the health professions, which underlies both the push from the exporting countries, as well as the pull from the recipient countries. Solutions should therefore be based on this wider perspective, interrelating health workforce imbalances between, but also within developing and developed countries.

  6. Analytical modeling and simulation of subthreshold behavior in nanoscale dual material gate AlGaN/GaN HEMT

    Science.gov (United States)

    Kumar, Sona P.; Agrawal, Anju; Chaujar, Rishu; Gupta, Mridula; Gupta, R. S.

    2008-07-01

    A two-dimensional (2-D) analytical model for a Dual Material Gate (DMG) AlGaN/GaN High Electron Mobility Transistor (HEMT) has been developed to demonstrate the unique attributes of this device structure in suppressing short channel effects (SCEs). The model accurately predicts the channel potential, electric field variation along the channel, and sub-threshold drain current, taking into account the effect of lengths of the two gate metals, their work functions, barrier layer thicknesses, and applied drain biases. It is seen that the SCEs and hot carrier effects in DMG AlGaN/GaN HEMT are suppressed due to the work function difference of the two metal gates, thereby screening the drain potential variations by the gate near the drain. Besides, a more uniform electric field along the channel leads to improved carrier transport efficiency. The accuracy of the results obtained from our analytical model has been verified using ATLAS device simulations.

  7. Liquefaction under drained condition, from the lab to reality ?

    Science.gov (United States)

    Clément, Cécile; Aharonov, Einat; Stojanova, Menka; Toussaint, Renaud

    2015-04-01

    Liquefaction constitutes a significant natural hazard in relation to earthquakes and landslides. This effect can cause buildings to tilt or sink into the soil, mud-volcanoes, floatation of buried objects, long-runout landslides, etc. In this work we present a new understanding regarding the mechanism by which buildings sink and tilt during liquefaction caused by earthquakes. Conventional understanding of liquefaction explains most observed cases as occurring in an undrained, under-compacted, layer of sandy soil saturated with water [1]: According to that understanding, the under compacted sandy layer has the tendency to compact when a load is applied. In our case the load comes from ground shaking during an earthquake. When the soil compacts, the fluid pore pressure rises. Because in undrained conditions the fluid cannot flow out, the pore pressure builds up. The weight of buildings is in this case transferred from the grains of the soil to the pore water. The soil loses its rigidity and it flows like a liquid. From this model scientists made theoretical and empirical laws for geotechnical use and buildings construction. Despite the success of this conventional model in many cases, liquefied soils were also observed under drained conditions, and in previously compacted soils, which doesn't agree with the assumption of the model quoted above. One of the famous liquefaction events is the Kobe port destruction during the 1995 earthquake. A simple calculation of the Deborah number following Goren et al ([2][3]) shows that the undrained constraint was not met below the Kobe port during the 1995 earthquake. We propose another model, of liquefaction in drained granular media. According to our model the mere presence of water in granular media is enough to cause liquefaction during an earthquake, provided that the water reaches close to the surface. Our computations are based on the buoyancy force, and we take into account the static fluid pressure only. For small

  8. Gauze Impregnated With Quaternary Ammonium Salt Reduces Bacterial Colonization of Surgical Drains After Breast Reconstruction.

    Science.gov (United States)

    Strong, Amy L; Wolfe, Emily T; Shank, Nina; Chaffin, Abigail E; Jansen, David A

    2018-06-01

    Surgical site infection after breast reconstruction is associated with increased length of hospital stay, readmission rates, cost, morbidity, and mortality. Identifying methods to reduce surgical site infection without the use of antibiotics may be beneficial at reducing antimicrobial resistance, reserving the use of antibiotics for more severe cases. Quaternary ammonium salts have previously been shown to be a safe and effective antimicrobial agent in the setting of in vitro and in vivo animal experiments. A retrospective study was conducted to investigate the antimicrobial properties of a quaternary ammonium salt, 3-trimethoxysilyl propyldimethyloctadecyl ammonium chloride (QAS-3PAC; Bio-spear), at reducing surgical drain site colonization and infection after breast reconstruction (deep inferior epigastric perforator flap reconstruction or tissue expander placement). Twenty patients were enrolled, with 14 surgical drains covered with nonimpregnated gauze and 17 surgical drains covered with QAS-3PAC impregnated gauze, for the purposes of investigating bacterial colonization. Antibiotic sensitivity analysis was also conducted when bacterial cultures were positive. The overall incidence of bacterial colonization of surgical drains was lower in the treatment group compared with the control group (17.6% vs 64.3%, respectively; P = 0.008). QAS-3PAC impregnated gauze reduced the incidence of bacterial colonization of surgical drains during the first (0.0% vs 33.3%) and second (33.3% vs 87.5%; P = 0.04) postoperative week. Furthermore, no enhanced antibiotic resistance was noted on drains treated with QAS-3PAC impregnated gauze. The results of this study suggest that QAS-3PAC impregnated gauze applied over surgical drains may be an effective method for reducing the incidence of bacterial colonization.

  9. Surface runoff and subsurface tile drain losses of neonicotinoids and companion herbicides at edge-of-field.

    Science.gov (United States)

    Chrétien, François; Giroux, Isabelle; Thériault, Georges; Gagnon, Patrick; Corriveau, Julie

    2017-05-01

    With their application as seed coatings, the use of neonicotinoid insecticides increased dramatically during the last decade. They are now frequently detected in aquatic ecosystems at concentrations susceptible to harm aquatic invertebrates at individual and population levels. This study intent was to document surface runoff and subsurface tile drain losses of two common neonicotinoids (thiamethoxam and clothianidin) compared to those of companion herbicides (atrazine, glyphosate, S-metolachlor and mesotrione) at the edge of a 22.5-ha field under a corn-soybean rotation. A total of 14 surface runoff and tile drain discharge events were sampled over two years. Events and annual unit mass losses were computed using flow-weighted concentrations and total surface runoff and tile drain flow volumes. Detection frequencies close to 100% in edge-of-field surface runoff and tile drain water samples were observed for thiamethoxam and clothianidin even though only thiamethoxam had been applied in the first year. In 2014, thiamethoxam median concentrations in surface runoff and tile drain samples were respectively 0.46 and 0.16 μg/L, while respective maximum concentrations of 2.20 and 0.44 μg/L were measured in surface runoff and tile drain samples during the first post-seeding storm event. For clothianidin, median concentrations in surface runoff and tile drain samples were 0.02 and 0.01, μg/L, and respective maximum concentrations were 0.07 μg/L and 0.05 μg/L. Surface runoff and tile drain discharge were key transport mechanisms with similar contributions of 53 and 47% of measured mass losses, respectively. Even if thiamethoxam was applied at a relatively low rate and had a low mass exportation value (0.3%), the relative toxicity was one to two orders of magnitude higher than those of the other chemicals applied in 2014 and 2015. Companion herbicides, except glyphosate in tile drains, exceeded their water quality guideline during one sampling campaign after

  10. Method of making a self-aligned schottky metal semi-conductor field effect transistor with buried source and drain

    International Nuclear Information System (INIS)

    Bol, I.

    1984-01-01

    A semi-conductor structure and particularly a high speed VLSI Self-Aligned Schottky Metal Semi-Conductor Field Effect Transistor with buried source and drain, fabricated by the ion implantation of source and drain areas at a predetermined range of depths followed by very localized laser annealing to electrically reactivate the amorphous buried source and drain areas thereby providing effective vertical separation of the channel from the buried source and drain respectively. Accordingly, spatial separations between the self-aligned gate-to-drain, and gate-to-source can be relatively very closely controlled by varying the doping intensity and duration of the implantation thereby reducing the series resistance and increasing the operating speed

  11. Model Development for Current–Voltage and Transconductance Characteristics of Normally-off AlN/GaN MOSHEMT

    International Nuclear Information System (INIS)

    Swain, R.; Jena, K.; Lenka, T. R.

    2016-01-01

    In this paper, an AlN/GaN-based MOSHEMT is proposed, in accordance to this, a charge control model has been developed analytically and simulated with MATLAB to predict the characteristics of threshold voltage, drain currents and transconductance. The physics based models for 2DEG density, threshold voltage and quantum capacitance in the channel has been put forward. By using these developed models, the drain current for both linear and saturation models is derived. The predicted threshold voltage with the variation of barrier thickness has been plotted. A positive threshold voltage can be obtained by decreasing the barrier thickness which builds up the foundation for enhancement mode MOSHEMT devices. The predicted I_d–V_g_s, I_d–V_d_s and transconductance characteristics show an excellent agreement with the experimental results and hence validate the model.

  12. Replacement of the level control of draining tanks MSRS and powered water heaters with the OVATION system in Asco NPP

    International Nuclear Information System (INIS)

    Serrano Jimenez, J.

    2012-01-01

    The current MSR drains and heaters tanks level control is local control individual, pneumatic and without action from Control room. The system has level switches for the generation of alarms, isolations and shots of bombs. Single control room operators have level alarms, final race of valves of control and indication of temperature and pressure of some tanks.

  13. Soft commutated direct current motor [summary of proposed paper

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, John S.

    1998-10-22

    A novel soft commutated direct current (DC) motor is introduced. The current of the commutated coil is intentionally drained before the brush disconnects the coil. This prevents the spark generation that normally occurs in conventional DC motors. A similar principle can be applied for DC generators.

  14. Experimental demonstration on the ultra-low source/drain resistance by metal-insulator-semiconductor contact structure in In0.53Ga0.47As field-effect transistors

    Directory of Open Access Journals (Sweden)

    M.-H. Liao

    2013-09-01

    Full Text Available In this work, we demonstrate the ultra-low contact resistivity of 6.7 × 10−9 Ω/cm2 by inserting 0.6-nm-ZnO between Al and InGaAs(Si: 1.5 × 1019 cm−3. The metal-insulator-semiconductor tunneling diode with 0.6-nm-ZnO exhibits nearly zero (0.03 eV barrier height. We apply this contact structure on the source/drain of implant-free In0.53Ga0.47As quantum-well metal-oxide-semiconductor field- effect transistors. The excellent on-state performance such as saturation drain current of 3 × 10−4 A/μm and peak transconductance of 1250 μS/μm is obtained which is attributed to the ultra-low source/drain resistance of 190 Ω-μm.

  15. Rare bile duct anomaly: B3 duct draining to gallbladder

    Directory of Open Access Journals (Sweden)

    Seung Eun Lee

    2016-01-01

    Full Text Available A 10-year-old girl presented with recurrent right upper abdominal pain and dyspepsia. Magnetic resonance cholangiopancreatography revealed a dilated common channel of intrahepatic bile duct of segment 3 (B3 and segment 4 (B4 drained into the gallbladder directly. The patient underwent laparoscopic cholecystectomy and Roux-en Y hepaticojejunostomy (B3-jejunostomy. Among the anatomical variability of the biliary system, the cholecystohepatic ducts are controversial in existence and incidence. We report a very rare variant of a cholecystohepatic duct in which the B3 duct drained into gallbladder directly and to the best of our knowledge this is the first report.

  16. Origin of the water drained by the tunnel Graton; Origen de las aguas que drena el tunel Graton

    Energy Technology Data Exchange (ETDEWEB)

    Plata B, A [International Atomic Energy Agency, Vienna (Austria). Dept. of Research and Isotopes; Rojas M, R [Instituto Peruano de Energia Nuclear, Lima (Peru)

    1992-12-01

    The research of the origin of the water drained by the Graton tunnel was attempted using isotope techniques. During the period of studies (April 1989-October 1992), four field work was executed to sample waters for chemistry, stable isotope and Tritium analysis, an to inject tracers and verify the possible infiltration from the Rimac and Blanco rivers to the tunnel. The results of the stable isotope analysis show that the water drained by the Graton tunnel comes from a basin around 300 meters above the average altitude of the basin where the Graton is located. The Tritium analysis show that the water is relatively modern. Using the model of total mixing, the residence times of the water drained at the km 0.5 and 2.5 are in the order to 45 years. The conductivities of the water of the tunnel is higher than the Rimac river ones because the influence of mine water. The chemical analysis of the water sampled at the downstream end of the tunnel, show that the conservative ions of the water kept almost constant during more than two years. The results of the work with artificial tracer show that there is no significant leakage from the Rimac and Blanco rivers to the Graton tunnel. So far, it can be concluded as a preliminary approach that the Graton tunnel drains relatively modern water originated in another basin. The hydrodynamics of the area of study seems to include a large storage on underground water in the system. The topography, geology and isotopic composition of the water samples, points to the upper Mantaro river basin as the possible source of part of the water drained by the Graton tunnel. (authors). 20 p. 2 figs., 7 ills., 4 tabs.

  17. Drains after Thyroidectomy for Benign Thyroid Disorders; Are ...

    African Journals Online (AJOL)

    Prophylactic drainage after thyroidectomy has been a regular practice at Kenyatta National Hospital( KNH). This has been ... stay and post-operative pain. Introduction. Prophylactic drains are still regularly used in ..... Total versus subtotal thyroidectomy for the management of benign multinodular goiter in an endemic region.

  18. Peat origin and land use effects on microbial activity, respiration dynamics and exo-enzyme activities in drained peat soils in the Netherlands

    NARCIS (Netherlands)

    Brouns, Karlijn; Keuskamp, Joost; Potkamp, Gerrit; Verhoeven, J.T.A.; Hefting, Mariet M.

    2016-01-01

    This study assessed the risk of decomposition-driven soil subsidence in drained peat soils in the Netherlands, contrasting in peat origin and current land use. In a full factorial design, fen peat and bog peat were sampled from sites in use for nature conservation and for dairy farming, which

  19. Soil settlement analysis in soft soil by using preloading system and prefabricated vertical draining runway of Kualanamu Airport

    Science.gov (United States)

    Roesyanto; Iskandar, R.; Silalahi, S. A.; Fadliansyah

    2018-02-01

    The method of soil improvement, using the combination of prefabricated vertical drain (PVD) and preloading, was used to accelerate the process of consolidation and the consolidation settlement in the runway of Kualanamu International Airport, which was constructed on the soft soil sediment like silty clay. In this research, the investigated area was the runway of Kualanamu International Airport zone I which had 11 meter-thickness of soft soil. Geotechnic instruments surveyed was settlement plate. Monitoring was done toward the behavior of landfill such as basic soil settlement. The result were compared with the analysis of finite element method of full scale in Mohr-Coulomb model by verifying the vertical drain of asymmetric unit cell and equivalent plane strain unit cell condition. The results of the research showed that there were an interesting behavior between the data in field observation and finite element of Mohr-Coulomb model. It was also found that the result of soil settlement of finite element method of Mohr-Coulomb model was closed to the result of settlement plate monitoring.

  20. Effect of Ion Flux (Dose Rate) in Source-Drain Extension Ion Implantation for 10-nm Node FinFET and Beyond on 300/450mm Platforms

    Science.gov (United States)

    Shen, Ming-Yi

    The improvement of wafer equipment productivity has been a continuous effort of the semiconductor industry. Higher productivity implies lower product price, which economically drives more demand from the market. This is desired by the semiconductor manufacturing industry. By raising the ion beam current of the ion implanter for 300/450mm platforms, it is possible to increase the throughput of the ion implanter. The resulting dose rate can be comparable to the performance of conventional ion implanters or higher, depending on beam current and beam size. Thus, effects caused by higher dose rate must be investigated further. One of the major applications of ion implantation (I/I) is source-drain extension (SDE) I/I for the silicon FinFET device. This study investigated the dose rate effects on the material properties and device performance of the 10-nm node silicon FinFET. In order to gain better understanding of the dose rate effects, the dose rate study is based on Synopsys Technology CAD (TCAD) process and device simulations that are calibrated and validated using available structural silicon fin samples. We have successfully shown that the kinetic monte carlo (KMC) I/I simulation can precisely model both the silicon amorphization and the arsenic distribution in the fin by comparing the KMC simulation results with TEM images. The results of the KMC I/I simulation show that at high dose rate more activated arsenic dopants were in the source-drain extension (SDE) region. This finding matches with the increased silicon amorphization caused by the high dose-rate I/I, given that the arsenic atoms could be more easily activated by the solid phase epitaxial regrowth process. This increased silicon amorphization led to not only higher arsenic activation near the spacer edge, but also less arsenic atoms straggling into the channel. Hence, it is possible to improve the throughput of the ion implanter when the dopants are implanted at high dose rate if the same doping level

  1. Study of novel junctionless Ge n-Tunneling Field-Effect Transistors with lightly doped drain (LDD) region

    Science.gov (United States)

    Liu, Xiangyu; Hu, Huiyong; Wang, Bin; Wang, Meng; Han, Genquan; Cui, Shimin; Zhang, Heming

    2017-02-01

    In this paper, a novel junctionless Ge n-Tunneling Field-Effect Transistors (TFET) structure is proposed. The simulation results show that Ion = 5.5 × 10-5A/μm is achieved. The junctionless device structure enhances Ion effectively and increases the region where significant BTBT occurs, comparing with the normal Ge-nTEFT. The impact of the lightly doped drain (LDD) region is investigated. A comparison of Ion and Ioff of the junctionless Ge n-TFET with different channel doping concentration ND and LDD doping concentration NLDD is studied. Ioff is reduced 1 order of magnitude with the optimized ND and NLDD are 1 × 1018cm-3 and 1 × 1017 cm-3, respectively. To reduce the gate induced drain leakage (GIDL) current, the impact of the sloped gate oxide structure is also studied. By employing the sloped gate oxide structure, the below 60 mV/decade subthreshold swing S = 46.2 mV/decade is achieved at Ion = 4.05 × 10-5A/μm and Ion/Ioff = 5.7 × 106.

  2. Spin-polarized current generated by magneto-electrical gating

    International Nuclear Information System (INIS)

    Ma Minjie; Jalil, Mansoor Bin Abdul; Tan, Seng Ghee

    2012-01-01

    We theoretically study spin-polarized current through a single electron tunneling transistor (SETT), in which a quantum dot (QD) is coupled to non-magnetic source and drain electrodes via tunnel junctions, and gated by a ferromagnetic (FM) electrode. The I–V characteristics of the device are investigated for both spin and charge currents, based on the non-equilibrium Green's function formalism. The FM electrode generates a magnetic field, which causes a Zeeman spin-splitting of the energy levels in the QD. By tuning the size of the Zeeman splitting and the source–drain bias, a fully spin-polarized current is generated. Additionally, by modulating the electrical gate bias, one can effect a complete switch of the polarization of the tunneling current from spin-up to spin-down current, or vice versa. - Highlights: ► The spin polarized transport through a single electron tunneling transistor is systematically studied. ► The study is based on Keldysh non-equilibrium Green's function and equation of motion method. ► A fully spin polarized current is observed. ► We propose to reverse current polarization by the means of gate voltage modulation. ► This device can be used as a bi-polarization current generator.

  3. Outcomes of Transhiatal and Intercostal Pleural Drain After Ivor Lewis Esophagectomy: Comparative Analysis of Two Consecutive Patient Cohorts.

    Science.gov (United States)

    Asti, Emanuele; Bernardi, Daniele; Bonitta, Gianluca; Bonavina, Luigi

    2018-05-01

    In a previous proof of concept study, transhiatal pleural drain has been shown to be safe and effective after hybrid Ivor Lewis esophagectomy. Aim of this study was to compare the short-term outcomes of transhiatal and intercostal pleural drainage. This is an observational retrospective cohort study. Two methods of pleural drainage were compared in patients undergoing hybrid Ivor Lewis esophagectomy. Patients treated with a transhiatal drain connected to a vacuum bag were compared to a historical cohort of patients treated with the conventional intercostal drain connected to underwater seal and suction. Postoperative morbidity, total and daily drainage output, serum albumin levels, and total dose of paracetamol and ketorolac administered on demand were recorded. Between January 2014 and December 2016, 50 patients with transhiatal drain and 50 with intercostal drains met the criteria for inclusion in the study. Demographic and clinicopathological variables were similar in the two groups. There was no statistically significant difference in the rate of postoperative complications. The total volume of drain output and the serum albumin levels were similar in the two groups. The total dose of ketorolac was significantly reduced in patients with transhiatal drain (P pleural drainage connected to a portable vacuum system could safely replace the intercostal drain after hybrid Ivor Lewis esophagectomy. It has the potential to reduce postoperative pain and use of nonsteroidal anti-inflammatory drugs, and to enhance recovery from surgery.

  4. Large-current-controllable carbon nanotube field-effect transistor in electrolyte solution

    Science.gov (United States)

    Myodo, Miho; Inaba, Masafumi; Ohara, Kazuyoshi; Kato, Ryogo; Kobayashi, Mikinori; Hirano, Yu; Suzuki, Kazuma; Kawarada, Hiroshi

    2015-05-01

    Large-current-controllable carbon nanotube field-effect transistors (CNT-FETs) were fabricated with mm-long CNT sheets. The sheets, synthesized by remote-plasma-enhanced CVD, contained both single- and double-walled CNTs. Titanium was deposited on the sheet as source and drain electrodes, and an electrolyte solution was used as a gate electrode (solution gate) to apply a gate voltage to the CNTs through electric double layers formed around the CNTs. The drain current came to be well modulated as electrolyte solution penetrated into the sheets, and one of the solution gate CNT-FETs was able to control a large current of over 2.5 A. In addition, we determined the transconductance parameter per tube and compared it with values for other CNT-FETs. The potential of CNT sheets for applications requiring the control of large current is exhibited in this study.

  5. On tridimensional rip current modeling

    Science.gov (United States)

    Marchesiello, Patrick; Benshila, Rachid; Almar, Rafael; Uchiyama, Yusuke; McWilliams, James C.; Shchepetkin, Alexander

    2015-12-01

    Do lateral shear instabilities of nearshore circulation account for a substantial part of Very Low-Frequency (VLF) variability? If yes, it would promote stirring and mixing of coastal waters and surf-shelf exchanges. Another question is whether tridimensional transient processes are important for instability generation. An innovative modeling system with tridimensional wave-current interactions was designed to investigate transient nearshore currents and interactions between nearshore and innershelf circulations. We present here some validation of rip current modeling for the Aquitanian coast of France, using in-situ and remote video sensing. We then proceed to show the benefits of 3D versus 2D (depth-mean flow) modeling of rip currents and their low-frequency variability. It appears that a large part of VLF motions is due to intrinsic variability of the tridimensional flow. 3D models may thus provide a valuable, only marginally more expensive alternative to conventional 2D approaches that miss the vertical flow structure and its nonlinear interaction with the depth-averaged flow.

  6. Characterization of Drain Surface Water: Environmental Profile, Degradation Level and Geo-statistic Monitoring

    International Nuclear Information System (INIS)

    Mumtaz, M.W.; Raza, M.A.; Ahmed, Z.; Abbas, M.N.; Hussain, M.

    2015-01-01

    The physico-chemical characterization of the surface water. Samples was carried out collected from nine sampling points of drain passing by the territory of Hafizabad city, Punjab, Pakistan. The water of drain is used by farmers for irrigation purposes in nearby agricultural fields. Twenty water quality parameters were evaluated in three turns and the results obtained were compared with the National Environmental Quality Standards (NEQS) municipal and industrial effluents prescribed limits. The highly significant difference (p<0.01) was recorded for the content of phenols, carbonyl compounds, cyanides, dissolved oxygen, biological oxygen demand, total soluble salts, total dissolved salts, nitrates and sulphates, whereas, the concentration of magnesium, potassium and oil and grease differed significantly (p<0.05) with respect to the sampling points on average basis. Non-significant difference (p>0.05) was noted for temperature, pH, electrical conductivity, hardness, calcium, sodium, chemical oxygen demand and chloride among water samples from different sampling points. Furthermore, the experimental results of different water quality parameters studied at nine sampling points of the drain were used and interpolated in ArcGIS 9.3 environment system using kriging techniques to obtain calculated values for the remaining locations of the Drain. (author)

  7. Circulation-based Modeling of Gravity Currents

    Science.gov (United States)

    Meiburg, E. H.; Borden, Z.

    2013-05-01

    Atmospheric and oceanic flows driven by predominantly horizontal density differences, such as sea breezes, thunderstorm outflows, powder snow avalanches, and turbidity currents, are frequently modeled as gravity currents. Efforts to develop simplified models of such currents date back to von Karman (1940), who considered a two-dimensional gravity current in an inviscid, irrotational and infinitely deep ambient. Benjamin (1968) presented an alternative model, focusing on the inviscid, irrotational flow past a gravity current in a finite-depth channel. More recently, Shin et al. (2004) proposed a model for gravity currents generated by partial-depth lock releases, considering a control volume that encompasses both fronts. All of the above models, in addition to the conservation of mass and horizontal momentum, invoke Bernoulli's law along some specific streamline in the flow field, in order to obtain a closed system of equations that can be solved for the front velocity as function of the current height. More recent computational investigations based on the Navier-Stokes equations, on the other hand, reproduce the dynamics of gravity currents based on the conservation of mass and momentum alone. We propose that it should therefore be possible to formulate a fundamental gravity current model without invoking Bernoulli's law. The talk will show that the front velocity of gravity currents can indeed be predicted as a function of their height from mass and momentum considerations alone, by considering the evolution of interfacial vorticity. This approach does not require information on the pressure field and therefore avoids the need for an energy closure argument such as those invoked by the earlier models. Predictions by the new theory are shown to be in close agreement with direct numerical simulation results. References Von Karman, T. 1940 The engineer grapples with nonlinear problems, Bull. Am. Math Soc. 46, 615-683. Benjamin, T.B. 1968 Gravity currents and related

  8. Comparison and evaluation of model structures for the simulation of pollution fluxes in a tile-drained river basin.

    Science.gov (United States)

    Hoang, Linh; van Griensven, Ann; van der Keur, Peter; Refsgaard, Jens Christian; Troldborg, Lars; Nilsson, Bertel; Mynett, Arthur

    2014-01-01

    The European Union Water Framework Directive requires an integrated pollution prevention plan at the river basin level. Hydrological river basin modeling tools are therefore promising tools to support the quantification of pollution originating from different sources. A limited number of studies have reported on the use of these models to predict pollution fluxes in tile-drained basins. This study focused on evaluating different modeling tools and modeling concepts to quantify the flow and nitrate fluxes in the Odense River basin using DAISY-MIKE SHE (DMS) and the Soil and Water Assessment Tool (SWAT). The results show that SWAT accurately predicted flow for daily and monthly time steps, whereas simulation of nitrate fluxes were more accurate at a monthly time step. In comparison to the DMS model, which takes into account the uncertainty of soil hydraulic and slurry parameters, SWAT results for flow and nitrate fit well within the range of DMS simulated values in high-flow periods but were slightly lower in low-flow periods. Despite the similarities of simulated flow and nitrate fluxes at the basin outlet, the two models predicted very different separations into flow components (overland flow, tile drainage, and groundwater flow) as well as nitrate fluxes from flow components. It was concluded that the assessment on which the model provides a better representation of the reality in terms of flow paths should not only be based on standard statistical metrics for the entire river basin but also needs to consider additional data, field experiments, and opinions of field experts. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  9. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  10. Photoactive TiO2 Films Formation by Drain Coating for Endosulfan Degradation

    Directory of Open Access Journals (Sweden)

    Natalia Tapia-Orozco

    2013-01-01

    Full Text Available Heterogeneous photocatalysis is an advanced oxidation process in which a photoactive catalyst, such as TiO2, is attached to a support to produce free radical species known as reactive oxygen species (ROS that can be used to break down toxic organic compounds. In this study, the draining time, annealing temperature, and draining/annealing cycles for TiO2 films grown by the drain coating method were evaluated using a 23 factorial experimental design to determine the photoactivity of the films via endosulfan degradation. The TiO2 films prepared with a large number of draining/annealing cycles at high temperatures enhanced (P>0.05 endosulfan degradation and superoxide radical generation after 30 minutes of illumination with UV light. We demonstrated a negative correlation (R2=0.69; P>0.01 between endosulfan degradation and superoxide radical generation. The endosulfan degradation rates were the highest at 30 minutes with the F6 film. In addition, films prepared using conditions F1, F4, and F8 underwent an adsorption/desorption process. The kinetic reaction constants, Kapp (min−1, were 0.0101, 0.0080, 0.0055, 0.0048, and 0.0035 for F6, F2, F5, F3, and F1, respectively. The endosulfan metabolites alcohol, ether, and lactone were detected and quantified at varying levels in all photocatalytic assays.

  11. Carbon balance of rewetted and drained peat soils used for biomass production: A mesocosm study

    DEFF Research Database (Denmark)

    Karki, Sandhya; Elsgaard, Lars; Kandel, Tanka

    2016-01-01

    of lower CO2 emissions without losing agricultural land. The present study quantified the carbon balance (CO2, CH4 and harvested biomass C) of rewetted and drained peat soils under intensively managed reed canary grass (RCG) cultivation. Mesocosms were maintained at five different ground water levels (GWL......), i.e., 0, 10, 20 cm below the soil surface, representing rewetted peat soils, and 30 and 40 cm below the soil surface, representing drained peat soils. Net ecosystem exchange (NEE) of CO2 and CH4 emissions were measured during the growing period of RCG (May to September) using transparent and opaque...... closed chamber methods. The average dry biomass yield was significantly lower from rewetted peat soils (12 Mg ha−1) than drained peat soils (15 Mg ha−1). Also, CO2 fluxes of gross primary production (GPP) and ecosystem respiration (ER) from rewetted peat soils were significantly lower than drained peat...

  12. English and the Brain Drain : An Uncertain Relationship

    NARCIS (Netherlands)

    Houtkamp, C.

    2016-01-01

    In his book Linguistic Justice for Europe and the World, Van Parijs analyses in one of his chapters the brain drain from non-Anglophone to Anglophone countries, which hurts the economic development of the nonAnglophone states. Van Parijs deems it clear that English is a very important factor to

  13. Multiyear nutrient removal performance of three constructed wetlands intercepting tile drain flows from grazed pastures.

    Science.gov (United States)

    Tanner, Chris C; Sukias, James P S

    2011-01-01

    Subsurface tile drain flows can be a major s ource of nurient loss from agricultural landscapes. This study quantifies flows and nitrogen and phosphorus yields from tile drains at three intensively grazed dairy pasture sites over 3- to 5-yr periods and evaluates the capacity of constructed wetlands occupying 0.66 to 1.6% of the drained catchments too reduce nutrient loads. Continuous flow records are combined with automated flow-proportional sampling of nutrient concentrations to calculate tile drain nutrient yields and wetland mass removal rates. Annual drainage water yields rangedfrom 193 to 564 mm (16-51% of rainfall) at two rain-fed sites and from 827 to 853 mm (43-51% of rainfall + irrigation) at an irrigated site. Annually, the tile drains exported 14 to 109 kg ha(-1) of total N (TN), of which 58 to 90% was nitrate-N. Constructed wetlands intercepting these flows removed 30 to 369 gTN m(-2) (7-63%) of influent loadings annually. Seasonal percentage nitrate-N and TN removal were negatively associated with wetland N mass loadings. Wetland P removal was poor in all wetlands, with 12 to 115% more total P exported annually overall than received. Annually, the tile drains exported 0.12 to 1.38 kg ha of total P, of which 15 to 93% was dissolved reactive P. Additional measures are required to reduce these losses or provide supplementary P removal. Wetland N removal performance could be improved by modifying drainage systems to release flows more gradually and improving irrigation practices to reduce drainage losses.

  14. The hydrology of a drained topographical depression within an agricutlural field in north-central Iowa

    Science.gov (United States)

    Roth, Jason L.; Capel, Paul D.

    2012-01-01

    North-central Iowa is an agriculturally intensive area comprising the southeastern portion of the Prairie Pothole Region, a landscape containing a high density of enclosed topographical depressions. Artificial drainage practices have been implemented throughout the area to facilitate agricultural production. Vertical surface drains are utilized to drain the topographical depressions that accumulate water. This study focuses on the hydrology of a drained topographical depression located in a 39.5 ha agricultural field. To assess the hydrology of the drained depression, a water balance was constructed for 11 ponding events during the 2008 growing season. Continuous pond and groundwater level data were obtained with pressure transducers. Flows into the vertical surface drain were calculated based on pond depth. Precipitation inflows and evaporative outflows of the ponds were calculated using climatic data. Groundwater levels were used to assess groundwater/pond interactions. Results of the water balances show distinct differences between the inflows to and outflows from the depression based on antecedent conditions. In wet conditions, groundwater inflow sustained the ponds. The ponds receded only after the groundwater level declined to below the land surface. In drier conditions, groundwater was not a source of water to the depression. During these drier conditions, infiltration comprised 30% of the outflows from the depression during declining pond stages. Over the entire study period, the surface drain, delivering water to the stream, was the largest outflow from the pond, accounting for 97% of the outflow, while evapotranspiration was just 2%. Precipitation onto the pond surface proved to be a minor component, accounting for 4% of the total inflows.

  15. Technical meeting on decommissioning of fast reactors after sodium draining. Working material

    International Nuclear Information System (INIS)

    2005-01-01

    The objective of the technical meeting was to provide a forum for in-depth scientific and technical exchange on topics related to the decommissioning experience with fast reactors, in particular with regard to the decommissioning of components after sodium draining. Accordingly, the scope of the meeting covers the review and analyses of the experience gained from the decommissioning of both active sodium loops and sodium cooled fast reactors (e.g., KNK II, Superphenix, RAPSODIE, EBR-II, FERMI, BN-350, BR-10). It is expected that the outcome of the meeting will contribute to the Agency initiative to preserve fast reactor data and knowledge. The main focus of the technical meeting was given on the decommissioning of both active loop and reactor components (e.g., the primary vessel of a sodium-cooled reactor) that have been drained of sodium, but that still conserve some residual amounts of sodium (e.g., films covering the entire surface of the component, or particular sodium heels that cannot be drained)

  16. Correlation of AlGaN/GaN high-electron-mobility transistors electroluminescence characteristics with current collapse

    Science.gov (United States)

    Ohi, Shintaro; Yamazaki, Taisei; Asubar, Joel T.; Tokuda, Hirokuni; Kuzuhara, Masaaki

    2018-02-01

    We report on the correlation between the electroluminescence and current collapse of AlGaN/GaN high-electron-mobility transistors (HEMTs). Standard passivated devices suffering from severe current collapse exhibited high-intensity whitish electroluminescence confined near the drain contact. In contrast, devices with reduced current collapse resulting from oxygen plasma treatment or GaN capping showed low-intensity reddish emission across the entire gate-drain access region. A qualitative explanation of this observed correlation between the current collapse and electroluminescence is presented. Our results demonstrate that electroluminescence analysis is a powerful tool not only for identifying high-field regions but also for assessing the degree of current collapse in AlGaN/GaN HEMTs.

  17. Differences in microbial community structure and nitrogen cycling in natural and drained tropical peatland soils.

    Science.gov (United States)

    Espenberg, Mikk; Truu, Marika; Mander, Ülo; Kasak, Kuno; Nõlvak, Hiie; Ligi, Teele; Oopkaup, Kristjan; Maddison, Martin; Truu, Jaak

    2018-03-16

    Tropical peatlands, which play a crucial role in the maintenance of different ecosystem services, are increasingly drained for agriculture, forestry, peat extraction and human settlement purposes. The present study investigated the differences between natural and drained sites of a tropical peatland in the community structure of soil bacteria and archaea and their potential to perform nitrogen transformation processes. The results indicate significant dissimilarities in the structure of soil bacterial and archaeal communities as well as nirK, nirS, nosZ, nifH and archaeal amoA gene-possessing microbial communities. The reduced denitrification and N 2 -fixing potential was detected in the drained tropical peatland soil. In undisturbed peatland soil, the N 2 O emission was primarily related to nirS-type denitrifiers and dissimilatory nitrate reduction to ammonium, while the conversion of N 2 O to N 2 was controlled by microbes possessing nosZ clade I genes. The denitrifying microbial community of the drained site differed significantly from the natural site community. The main reducers of N 2 O were microbes harbouring nosZ clade II genes in the drained site. Additionally, the importance of DNRA process as one of the controlling mechanisms of N 2 O fluxes in the natural peatlands of the tropics revealed from the results of the study.

  18. Anomie and the "Brain Drain": A Sociological Explanation.

    Science.gov (United States)

    Karadima, Oscar

    The concept of anomie is proposed as one sociological variable that may explain the "brain drain" phenomenon (i.e., the movement of highly qualified personnel from their country of origin to another, most often a more developed, technologically advanced country). It is hypothesized that the higher the level of anomie found among…

  19. Organic loss in drained wetland: managing the carbon footprint

    NARCIS (Netherlands)

    Durham, B.; van de Noort, R.; Martens, V.V.; Vorenhout, M.

    2012-01-01

    The recent installation of land drains at Star Carr, Yorkshire, UK, has been linked with loss of preservation quality in this important Mesolithic buried landscape, challenging the PARIS principle. Historically captured organic carbon, including organic artefacts, is being converted to soluble

  20. A vapor generator equipped with an advanced drain device for the secondary side of the tubes plate

    International Nuclear Information System (INIS)

    Valadon, C.

    1995-01-01

    A draining design is proposed for the tube plate secondary side in a PWR type reactor, that does not interfere with the water flush 'street' thus allowing for an easy inspection and maintenance in the lower part of the tube bundle. The draining system is composed of a main groove on the upper side of the tube plate, which is connected to draining means situated outside the vapor generator. 6 fig

  1. Use of laterally placed vacuum drains for management of aural hematomas in five dogs.

    Science.gov (United States)

    Pavletic, Michael M

    2015-01-01

    5 dogs (a Newfoundland, Golden Retriever, Shiba Inu, Staffordshire Terrier, and Vizsla) were referred for evaluation and treatment of unilateral aural hematomas within a week after their formation. Aural hematomas involved the left (3) or right (2) ears. With patients under anesthesia, the aural hematomas were approached surgically from the convex, or lateral, pinnal surface. Two small incisions were used to position a vacuum drain into the incised hematoma cavity. The drain exited at the base of the pinna and adjacent cervical skin. The free end of the drain was attached to a vacuum reservoir for 18 to 21 days. Drains and skin sutures were removed at this time along with the protective Elizabethan collar. All hematomas resolved and surgical sites healed during the minimum 6-month follow-up period. Cosmetic results were considered excellent in 4 of 5 patients. Slight wrinkling of the pinna in 1 patient resulted from asymmetric enlargement of the cartilaginous walls of the hematoma, where vacuum application resulted in a slight folding of the redundant lateral cartilage wall. The described treatment was efficient, economical, and minimally invasive and required no bandaging or wound care. Placement of the drain tubing on the convex (lateral) aspect sheltered the system from displacement by patients with an Elizabethan collar in place. Overall cosmetic results were excellent; asymmetric enlargement of the cartilaginous walls of the hematoma with slight folding of the pinna was seen in 1 patient.

  2. Two-dimensional analytical model of double-gate tunnel FETs with interface trapped charges including effects of channel mobile charge carriers

    Science.gov (United States)

    Xu, Huifang; Dai, Yuehua

    2017-02-01

    A two-dimensional analytical model of double-gate (DG) tunneling field-effect transistors (TFETs) with interface trapped charges is proposed in this paper. The influence of the channel mobile charges on the potential profile is also taken into account in order to improve the accuracy of the models. On the basis of potential profile, the electric field is derived and the expression for the drain current is obtained by integrating the BTBT generation rate. The model can be used to study the impact of interface trapped charges on the surface potential, the shortest tunneling length, the drain current and the threshold voltage for varying interface trapped charge densities, length of damaged region as well as the structural parameters of the DG TFET and can also be utilized to design the charge trapped memory devices based on TFET. The biggest advantage of this model is that it is more accurate, and in its expression there are no fitting parameters with small calculating amount. Very good agreements for both the potential, drain current and threshold voltage are observed between the model calculations and the simulated results. Project supported by the National Natural Science Foundation of China (No. 61376106), the University Natural Science Research Key Project of Anhui Province (No. KJ2016A169), and the Introduced Talents Project of Anhui Science and Technology University.

  3. Comparative effect of tube drain on post operative inflammatory complications of impacted mandibular third molar surgery College Hospital, Ibadan, Nigeria.

    Science.gov (United States)

    Obimakinde, O S; Fasola, A O; Arotiba, J T; Okoje, V N; Obiechina, A E

    2010-09-01

    Swelling, pain and trismus are acute reversible inflammatory complications of impacted mandibular third molar (M3) surgery. They contribute to the deterioration of quality of life and loss of several useful working hours. This study aimed to investigate whether the use of a surgical drain following M3 surgery can minimise these inflammatory complications. Eighty consecutive patients who gave consent were enrolled into the study. Patients were assigned into two groups (drain and no drain) by systematic sampling method which was modified to ensure matching of patients by age, sex and spatial relationship of the impacted mandibular third molar. The patients in the drain group (n=40) had a Foley's catheter drain inserted into the wound after the surgical procedure while the patients in the no drain group (n=40) had their wound closed without the use of drain. All patients had primary wound closure with 3.0 black silk sutures after the procedure. Demographic data, cheek dimension and maximal mouth opening were recorded before the procedure. Pain, swelling and trismus were evaluated in the two groups at 24 hours, 48 hours and 7th day after surgery. Post operative swelling and visual analogue scale score for pain were comparatively lesser in the drain group patients. The maximal interincisal distance was also more in the drain group patients. The findings from this study indicated that there is a significant benefit of using a surgical drain in minimising postoperative oedema, pain and trismus following surgical removal of impacted mandibular third molar.

  4. Influence of microstructure in current draining efficiency in magnesium sacrificial anodes; Influencia de la microestructura en la eficiencia de drenado de corriente en anodos de sacrificio de magnesio

    Energy Technology Data Exchange (ETDEWEB)

    Robles P, E F [Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico)

    1994-12-31

    In the last few years the efficiency of magnesium anodes used as cathodic protection of structures and metallic components, has presented outstanding variations. In spite of the fulfillment with the standard of chemicomposition, the working efficiency is low, existing the possibility that this be own to microstructural variations still not studied. For this reason, in the present work are shown some experiences with solidification of magnesium, in order to observe the influence of the structure of casting in the efficiency of current drain. For this purpose, pure magnesium (99.98%) was melt in graphite crucibles using protecting flux, pouring then in three different moulds: graphite, steel and aluminium, this last supplied with refrigeration using water as coolant up till now, the attained structures does not exert a determinant influence in the efficiency of magnesium anodes, and for this reason it is recommended to carry out thermomechanical treatments to continue with the study. (Author).

  5. Influence of pleural drain insertion in lung function of patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Ozelami Vieira, Irinea Beatriz Carvalho; Vieira, Fabiano F; Abrão, João; Gastaldi, Ada Clarice

    2012-01-01

    Longitudinal, prospective, randomized, blinded Trial to assess the influence of pleural drain (non-toxic PVC) site of insertion on lung function and postoperative pain of patients undergoing coronary artery bypass grafting in the first three days post-surgery and immediately after chest tube removal. Thirty six patients scheduled for elective myocardial revascularization with cardiopulmonary bypass (CPB) were randomly allocated into two groups: SX group (subxiphoid) and IC group (intercostal drain). Spirometry, arterial blood gases, and pain tests were recorded. Thirty one patients were selected, 16 in SX group and 15 in IC group. Postoperative (PO) spirometric values were higher in SX than in IC group (ppleural drain location on breathing. PaO(2) on the second PO increased significantly in SX group compared with IC group (pDrain with insertion in the subxiphoid region causes less change in lung function and discomfort, allowing better recovery of respiratory parameters. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  6. Navajo Nation Brain Drain: An Exploration of Returning College Graduates’ Perspectives

    Directory of Open Access Journals (Sweden)

    Quintina Ava Bearchief-Adolpho

    2017-01-01

    Full Text Available American Indian tribes face the phenomenon known across the world as the brain drain. They invest millions of dollars in educating their members only to have little return on their investment. Many nation members leave reservations to get postsecondary education but never return. Those who get education off the reservation and choose to return are the exception to this rule. Although there is an abundance of literature regarding brain drain across the world, there has been little research done with American Indians. In order to begin to understand the brain drain phenomenon, this study analyzed unstructured qualitative interviews with 17 Navajo Nation members who left their reservation, obtained a degree, and returned to work on the reservation. Themes resulting from the hermeneutic analysis of transcribed interviews were (a Family Support, (b Community, (c Cultural Identity, (d the Simple Life, (e Reservation Economy, and (f Commitment to the Reservation. The analysis found that constant, lengthy, and meaningful relationships were motivating factors in drawing participants back to contribute to their reservations. Further study is needed to understand how communities and tribes can ensure that these relationships are built and maintained.

  7. Source/drain electrodes contact effect on the stability of bottom-contact pentacene field-effect transistors

    Directory of Open Access Journals (Sweden)

    Xinge Yu

    2012-06-01

    Full Text Available Bottom-contact pentacene field-effect transistors were fabricated with a PMMA dielectric layer, and the air stability of the transistors was investigated. To characterize the device stability, the field-effect transistors were exposed to ambient conditions for 30 days and subsequently characterized. The degradation of electrical performance was traced to study the variation of field-effect mobility, saturation current and off-state current. By investigating the morphology variance of the pentacene film at the channel and source/drain (S/D contact regions by atomic force microscopy, it was clear that the morphology of the pentacene film adhered to the S/D degenerated dramatically. Moreover, by studying the variation of contact resistance in detail, it was found that the S/D contact effect was the main reason for the degradation in performance.

  8. Rebalancing brain drain: exploring resource reallocation to address health worker migration and promote global health.

    Science.gov (United States)

    Mackey, Timothy Ken; Liang, Bryan Albert

    2012-09-01

    Global public health is threatened by an imbalance in health worker migration from resource-poor countries to developed countries. This "brain drain" results in health workforce shortages, health system weakening, and economic loss and waste, threatening the well-being of vulnerable populations and effectiveness of global health interventions. Current structural imbalances in resource allocation and global incentive structures have resulted in 57 countries identified by WHO as having a "critical shortage" of health workers. Yet current efforts to strengthen domestic health systems have fallen short in addressing this issue. Instead, global solutions should focus on sustainable forms of equitable resource sharing. This can be accomplished by adoption of mandatory global resource and staff-sharing programs in conjunction with implementation of state-based health services corps. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Environmental impacts of alternative agricultural uses of poorly drained farm land in Ireland.

    Science.gov (United States)

    Sharma, Pooja; Humphreys, James; Holden, Nicholas M

    2018-05-07

    Abolition of the milk quota in the European Union and favourable market conditions have stimulated the expansion of the dairy sector in Ireland, causing more milk to be produced from poorly drained land. This work evaluated the environmental impacts of alternative agricultural uses for poorly drained farm land in Ireland using life cycle assessment (LCA). The avoided burden of the displaced product was used to calculate the net environmental consequences in the context of regional or global markets. The impact categories evaluated were climate change, eutrophication and acidification, all expressed per hectare of land for the alternative land uses, which were pasture-based milk, suckler beef and lowland sheep production and coniferous forestry. Beef had the lowest net climate change impact with global marginal and average product substitution while sheep had the lowest net climate change impact with European displaced product. For net eutrophication and acidification, dairy had the lowest impacts with European and global average displaced product. With global marginal displaced product, forestry had the lowest net eutrophication impact and sheep had the lowest net acidification impact. From an Irish perspective, forestry would generate the lowest environmental impacts and would also increase soil carbon stock, but this was not the best land use option from global perspective. Overall it can be concluded that a pasture based dairy or sheep system would have the greatest net global impact reduction (i.e. greatest global benefit) as land use options for farms with poorly drained soils. Prioritizing climate change, suckler beef system would perhaps be more favourable. It is clear that the choice of the displaced regional or global co-product from the market has a great influence on the results and there is a need to consider more detailed consumption modelling to better understand the substitution process. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. The role of external drains and peritoneal conduits in the treatment of recurrent chronic subdural hematoma.

    Science.gov (United States)

    Santarius, Thomas; Qureshi, Hammad U; Sivakumaran, Ram; Kirkpatrick, Peter J; Kirollos, Ramez W; Hutchinson, Peter J

    2010-06-01

    A considerable body of evidence supporting the use of external drainage after evacuation of primary chronic subdural hematoma (CSDH) exists in the literature. However, no systematic study of the value of postoperative drainage in the treatment of recurrent CSDH has been published. The aim of the study was to investigate external drains and subdural-to-peritoneal conduit in the treatment of recurrent CSDH. A retrospective review of cases of CSDH treated in our institution between October 2002 and October 2006 was conducted. During the study period, 408 patients had burr hole evacuation. Sixty-four patients (15.9%) had treatment for recurrence. One patient had craniotomy, and the remaining 63 had another burr hole evacuation: 36 without placement of a drain (BHO), 14 with external drainage (SED), and 13 with placement of subdural-peritoneal catheter (SPC). Fifteen patients (24%) developed a secondary recurrence requiring a third drainage procedure. Postoperative drainage (SED or SPC) was associated with a significantly lower secondary recurrence rate when compared to BHO: 3/27 (11%) versus 12/36 (33%) (χ(2), P=.040). There was no significant difference in recurrence rates between SED and SPC. Postoperative complications included acute subdural hematoma (2), subdural empyema (2), brain edema (2), pneumonia (3), and in-hospital death (2). None of the complications was associated with the use of a specific technique. The results indicate that, as in the treatment of primary CSDHs, the use of drain (SED or SPC) with burr hole evacuation is safe and is associated with lower recurrence rate. Further investigation is needed to clarify the indications of currently available surgical techniques in the treatment of recurrent CSDH. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. Enhanced performance of a-IGZO thin-film transistors by forming AZO/IGZO heterojunction source/drain contacts

    International Nuclear Information System (INIS)

    Zou, Xiao; Fang, Guojia; Wan, Jiawei; Liu, Nishuang; Long, Hao; Wang, Haolin; Zhao, Xingzhong

    2011-01-01

    A low-cost Al-doped ZnO (AZO) thin film was deposited by radio-frequency magnetron sputtering with different Ar/O 2 flow ratios. The optical and electrical properties of an AZO film were investigated. A highly conductive AZO film was inserted between the amorphous InGaZnO (a-IGZO) channel and the metal Al electrode to form a heterojunction source/drain contact, and bottom-gate amorphous a-IGZO thin-film transistors (TFTs) with a high κ HfON gate dielectric were fabricated. The AZO film reduced the source/drain contact resistivity down to 79 Ω cm. Enhanced device performance of a-IGZO TFT with Al/AZO bi-layer S/D electrodes (W/L = 500/40 µm) was achieved with a saturation mobility of 13.7 cm 2 V −1 s −1 , a threshold voltage of 0.6 V, an on-off current ratio of 4.7 × 10 6 , and a subthreshold gate voltage swing of 0.25 V dec −1 . It demonstrated the potential application of the AZO film as a promising S/D contact material for the fabrication of the high performance TFTs

  12. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    Science.gov (United States)

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  13. Brain drain or brain gain : The case of Suriname

    NARCIS (Netherlands)

    T.W. Dulam (Tina)

    2015-01-01

    markdownabstractAbstract Brain drain refers to the emigration of highly skilled individuals mostly from a less developed (home) to a developed country (destination) thereby reducing the capacity of the home country to generate welfare for its population. In the literature there is much written

  14. Structural alterations in tumor-draining lymph nodes before papillary thyroid carcinoma metastasis.

    Science.gov (United States)

    Hinson, Andrew M; Massoll, Nicole A; Jolly, Lee Ann; Stack, Brendan C; Bodenner, Donald L; Franco, Aime T

    2017-08-01

    The purpose of this study was to define and characterize the thyroid tumor-draining lymph nodes in genetically engineered mice harboring thyroid-specific expression of oncogenic Braf V600E with and without Pten insufficiency. After intratumoral injection of methylene blue, the lymphatic drainage of the thyroid gland was visualized in real time. The thyroid gland/tumor was resected en bloc with the respiratory system for histological analysis. Although mice harboring Braf V600E mutations were smaller in body size compared with their wild-type (WT) littermates, the size of their thyroid glands and deep cervical lymph nodes were significantly larger. Additionally, the tumor-draining lymph nodes showed increased and enlarged lymphatic sinuses that were distributed throughout the cortex and medulla. Tumor-reactive lymphadenopathy and histiocytosis, but no frank metastases, were observed in all mice harboring Braf V600E mutations. The tumor-draining lymph nodes undergo significant structural alterations in immunocompetent mice, and this may represent a primer for papillary thyroid carcinoma (PTC) metastasis. © 2017 Wiley Periodicals, Inc.

  15. Transport of water, bromide ion, nutrients and the pesticides bentazone and imidacloprid in a cracking, tile drained clay soil at Andelst, the Netherlands

    NARCIS (Netherlands)

    Smelt, J.H.; Hendriks, R.F.A.; Pas, van der L.J.T.; Matser, A.M.; Toorn, van den A.; Oostindie, K.; Dijk-Hooijer, van O.M.; Boesten, J.J.T.I.; Scorza Júnior, R.P.

    2003-01-01

    The aim of this study was to perform a field experiment to collect a high quality data set suitable for validating and improving pesticide leaching models and nutrient leaching models for drained and cracking clay soils. The transport of water, bromide, nutrients and the pesticides bentazone and

  16. 'Brain drain' from Serbia: One face of globalization of education?

    Directory of Open Access Journals (Sweden)

    Avramović Zoran

    2012-01-01

    Full Text Available In this paper we point out the role of the practice and ideology of globalization in brain drain process from Serbia. The listed data are based on the large-scale departure of highly educated persons from Serbia to the counties of West Europe and the USA. The dynamics, proportions and tendencies are analysed the role of the educational system in the process of departure of highly educated people and the reasons and consequences of the departure of scientist and engineering experts. In this article, education policy as state financial support are critical analysed. For Serbia, as the relatively undeveloped country in the middle of the modernization processes, this process has far-reaching effects on the social development. So, here we implied the possible solutions for the problem of brain drain.

  17. How Might Draining Lake Campotosto Affect Stress and Seismicity on the Monte Gorzano Normal Fault, Central Italy?

    Science.gov (United States)

    Verdecchia, A.; Deng, K.; Harrington, R. M.; Liu, Y.

    2017-12-01

    It is broadly accepted that large variations of water level in reservoirs may affect the stress state on nearby faults. While most studies consider the relationship between lake impoundment and the occurrence of large earthquakes or seismicity rate increases in the surrounding region, very few examples focus on the effects of lake drainage. The second largest reservoir in Europe, Lake Campotosto, is located on the hanging wall of the Monte Gorzano fault, an active normal fault responsible for at least two M ≥ 6 earthquakes in historical times. The northern part of this fault ruptured during the August 24, 2016, Mw 6.0 Amatrice earthquake, increasing the probability for a future large event on the southern section where an aftershock sequence is still ongoing. The proximity of the Campotosto reservoir to the active fault aroused general concern with respect to the stability of the three dams bounding the reservoir if the southern part of the Monte Gorzano fault produces a moderate earthquake. Local officials have proposed draining the reservoir as hazard mitigation strategy to avoid possible future catastrophes. In efforts to assess how draining the reservoir might affect earthquake nucleation on the fault, we use a finite-element poroelastic model to calculate the evolution of stress and pore pressure in terms of Coulomb stress changes that would be induced on the Monte Gorzano fault by emptying the Lake Campotosto reservoir. Preliminary results show that an instantaneous drainage of the lake will produce positive Coulomb stress changes, mostly on the shallower part of the fault (0 to 2 km), while a stress drop of the order of 0.2 bar is expected on the Monte Gorzano fault between 0 and 8 km depth. Earthquake hypocenters on the southern portion of the fault currently nucleate between 5 and 13 km depth, with activity distributed nearby the reservoir. Upcoming work will model the effects of varying fault geometry and elastic parameters, including geological

  18. Validation of a triangular quantum well model for GaN-based HEMTs used in pH and dipole moment sensing

    International Nuclear Information System (INIS)

    Rabbaa, S; Stiens, J

    2012-01-01

    Gallium nitride (GaN) is a relatively new semiconductor material that has the potential of replacing gallium arsenide (GaAs) in some of the more recent technological applications, for example chemical sensor applications. In this paper, we introduce a triangular quantum well model for an undoped AlGaN/GaN high electron mobility transistor (HEMT) structure used as a chemical and biological sensor for pH and dipole moment measurements of polar liquids. We have performed theoretical calculations related to the HEMT characteristics and we have compared them with experimental measurements carried out in many previous papers. These calculations include the current-voltage (I-V) characteristics of the device, the surface potential, the change in the drain current with the dipole moment and the drain current as a function of pH. The results exhibit good agreement with experimental measurements for different polar liquids and electrolyte solutions. It is also found that the drain current of the device exhibits a large linear variation with the dipole moment, and that the surface potential and the drain current depend strongly on the pH. Therefore, it can distinguish molecules with slightly different dipole moments and solutions with small variations in pH. The ability of the device to sense biomolecules (such as proteins) with very large dipole moments is investigated.

  19. Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.

    Science.gov (United States)

    Soufron, Jacques

    2015-10-01

    After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.

  20. Miniinvasive paracentetic drain surgical interventions under ultrasonic control concerning liquid formations of abdominal cavity

    Directory of Open Access Journals (Sweden)

    G.I. Ohrimenko

    2013-08-01

    Full Text Available Entry. Presently miniinvasive surgical interventions under ultrasonic control became the method of choice in treatment of quite a number of abdominal and retroperitoneal organs diseases, and their complications. These operations have a row of advantages, as compared to open and laparoscopic ones: comparative simplicity, insignificant infecting of abdominal region, least of intra- and postoperative complications. Actuality of problem is conditioned by that indications to the use of paracentetic drain surgical interventions, most optimal methods of preoperative diagnostic, features of postoperative treatment of patients remain not enough studied. Research aim. To study the results of diagnostics and treatment of patients with liquid formations of abdominal cavity that were exposed to miniinvasive surgical interventions under ultrasonic control and, on the basis of it, to work out an optimal curative diagnostic algorithm. Materials and research methods. The results of treatment of 25 patients with liquid formations of abdominal cavity are analyzed. They were submitted to miniinvasive paracentetic drain surgical interventions under ultrasonic control. The pseudocysts of pancreas were in 16 patients, abscesses of abdominal cavity – in 2 patients. Research results. Intraoperative complications were not marked. Postoperative complications were observed in 5 patients. Among them there were inadequate drainage of all cavities of multicamerate abscess of the liver in 2 patients, progress of sacculated uremic peritonitis developing in presence of ascites in one patient, and arrosive hemorrhage in the cavity of pancreas pseudocyst in 2 persons. It is determined that it is necessary to include the spiral computer tomography to the complex of preoperative inspection of patients that allows to diagnose multicamerate abscess of the liver in time and to drain all the additional cavities adequately. 2 patients after paracentetic drain surgical interventions

  1. Peat accumulation in drained thermokarst lake basins in continuous, ice-rich permafrost, northern Seward Peninsula, Alaska

    Science.gov (United States)

    Jones, Miriam C.; Grosse, Guido; Jones, Benjamin M.; Anthony, Katey Walter

    2012-01-01

    Thermokarst lakes and peat-accumulating drained lake basins cover a substantial portion of Arctic lowland landscapes, yet the role of thermokarst lake drainage and ensuing peat formation in landscape-scale carbon (C) budgets remains understudied. Here we use measurements of terrestrial peat thickness, bulk density, organic matter content, and basal radiocarbon age from permafrost cores, soil pits, and exposures in vegetated, drained lake basins to characterize regional lake drainage chronology, C accumulation rates, and the role of thermokarst-lake cycling in carbon dynamics throughout the Holocene on the northern Seward Peninsula, Alaska. Most detectable lake drainage events occurred within the last 4,000 years with the highest drainage frequency during the medieval climate anomaly. Peat accumulation rates were highest in young (50–500 years) drained lake basins (35.2 g C m−2 yr−1) and decreased exponentially with time since drainage to 9 g C m−2 yr−1 in the oldest basins. Spatial analyses of terrestrial peat depth, basal peat radiocarbon ages, basin geomorphology, and satellite-derived land surface properties (Normalized Difference Vegetation Index (NDVI); Minimum Noise Fraction (MNF)) from Landsat satellite data revealed significant relationships between peat thickness and mean basin NDVI or MNF. By upscaling observed relationships, we infer that drained thermokarst lake basins, covering 391 km2 (76%) of the 515 km2 study region, store 6.4–6.6 Tg organic C in drained lake basin terrestrial peat. Peat accumulation in drained lake basins likely serves to offset greenhouse gas release from thermokarst-impacted landscapes and should be incorporated in landscape-scale C budgets.

  2. 77 FR 30886 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain

    Science.gov (United States)

    2012-05-24

    ... interpretation and installed unblockable drain covers and now would have to go back and ``re-do'' their work... compliance and whether the pool operator is seeking a plan review and not just limited advice about how to... secondary anti-entrapment system to come into compliance, unless the pool uses a gravity drain system or the...

  3. Oculo-peritoneal shunt: draining aqueous humor to the peritoneum

    Directory of Open Access Journals (Sweden)

    Ana Maldonado-Junyent

    2015-04-01

    Full Text Available In 2010, there were estimated to be approximately 60.5 million people with glaucoma. This number is expected to increase to 79.6 million by 2020. In 2010, there were 8.4 million people with bilateral blindness caused by glaucoma, and this number is expected in increase to 11.2 million by 2020. Filtering implants are special devices that have been developed to reduce intraocular pressure in patients with refractory glaucoma. The success rate of these implants is relatively low, and they continue to fail over time. To avoid failure caused by the formation of scar tissue around the implants, attempts have been made to drain the aqueous humor to various sites, including the venous system, lacrimal sac, sinuses, and conjunctival fornix. Recently, a system to shunt aqueous humor from the anterior chamber to the peritoneum has been developed. The surgical technique involved in this system is a modification of the technique currently used by neurosurgeons for the treatment of hydrocephalus. We present the first case operated using this technique.

  4. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  5. Should I stay or should I go? An institutional approach to brain drain

    OpenAIRE

    Cassar, Lea; Frey, Bruno S

    2010-01-01

    This paper suggests that institutional factors which reward social net- works at the expenses of productivity can play an important role in ex- plaining brain drain. The e€ects of social networks on brain drain are analyzed in a decision theory framework with asymmetric information. We distinguish between the role of insidership and personal connections. The larger the cost of being an outsider, the smaller is the number and the average ability of researchers working in the domestic job mar...

  6. Risk assessment of K basin twelve-inch drain valve failure from a postulated seismic initiating event

    International Nuclear Information System (INIS)

    MORGAN, R.G.

    1999-01-01

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rates which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations suggest that only the valve's bonnet and stem are exposed above the basin concrete floor. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this activity are to: (1) evaluate the risk of damaging the three twelve-inch drain valves located along the north wall of the main basin from a seismic initiating event, and (2) determine the associated potential leak rate from a damaged valve

  7. Risk assessment of K basin twelve-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-04-06

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rates which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations suggest that only the valve's bonnet and stem are exposed above the basin concrete floor. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this activity are to: (1) evaluate the risk of damaging the three twelve-inch drain valves located along the north wall of the main basin from a seismic initiating event, and (2) determine the associated potential leak rate from a damaged valve.

  8. A low specific on-resistance SOI MOSFET with dual gates and a recessed drain

    International Nuclear Information System (INIS)

    Luo Xiao-Rong; Hu Gang-Yi; Zhang Zheng-Yuan; Luo Yin-Chun; Fan Ye; Wang Xiao-Wei; Fan Yuan-Hang; Cai Jin-Yong; Wang Pei; Zhou Kun

    2013-01-01

    A low specific on-resistance (R on,sp ) integrable silicon-on-insulator (SOI) metal-oxide semiconductor field-effect transistor (MOSFET) is proposed and investigated by simulation. The MOSFET features a recessed drain as well as dual gates, which consist of a planar gate and a trench gate extended to the buried oxide layer (BOX) (DGRD MOSFET). First, the dual gates form dual conduction channels, and the extended trench gate also acts as a field plate to improve the electric field distribution. Second, the combination of the trench gate and the recessed drain widens the vertical conduction area and shortens the current path. Third, the P-type top layer not only enhances the drift doping concentration but also modulates the surface electric field distributions. All of these sharply reduce R on,sp and maintain a high breakdown voltage (BV). The BV of 233 V and R on,sp of 4.151 mΩ·cm 2 (V GS = 15 V) are obtained for the DGRD MOSFET with 15-μm half-cell pitch. Compared with the trench gate SOI MOSFET and the conventional MOSFET, R on,sp of the DGRD MOSFET decreases by 36% and 33% with the same BV, respectively. The trench gate extended to the BOX synchronously acts as a dielectric isolation trench, simplifying the fabrication processes. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  9. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Mohsen Mirmohammad-Sadeghi

    2017-01-01

    Full Text Available Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001, but the trend of pain score between groups was not significantly different (P = 0.097. The frequency of tamponade and atrial fibrillation (AF were significantly lower in Jackson-Pratt drain group (P < 0.05. Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  10. Wound healing without drains in posterior spinal fusion in idiopathic scoliosis

    International Nuclear Information System (INIS)

    Alsiddiky, A.; Nisar, K.A.; Alhuzaimi, F.; Albishi, W.; Alnuaim, B.; Albarrag, M.; Meo, S.A.

    2013-01-01

    To determine the frequency of wound infection and neurological injuries in patients with idiopathic scoliosis who underwent posterior spinal fusion without use of drains. Study Design: Case series. Place and Duration of Study: Department of Orthopaedics, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia, from February 2007 to June 2010. Methodology: Patients who underwent similar technique of posterior spinal fusion instrumentation for the correction of scoliosis without use of drain were included. Wound Demographics, wound healing, complications and duration of hospital stay were considered and described as frequency and mean values. Results: The average age at the time of surgery was 12.80 +- 1.30 years, duration of surgery was 3.80 +- 0.86 hours, hospital stay was 3.84 +- 0.78 days and patients were followed-up over the last 30 months. There was no incidence of any neurological complication and deep infection. However, only 2 (4.16%) cases with superficial skin infection were treated with dressing and antibiotics with full recovery. Conclusion: The wound healing is adequate without using drain for patients with idiopathic scoliosis who underwent posterior spinal fusion and instrumentation when good wash, watertight closure technique and appropriate antibiotics coverage is provided. (author)

  11. Design and construction of a French drain for groundwater diversion in solid waste storage area six at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Davis, E.C.; Stansfield, R.G.

    1984-05-01

    Engineering modifiations or engineered barriers have been suggested as a possible means of improving the performance of low-level waste disposal sites located in the humid eastern United States. Design and construction of a passive French drain, located in Solid Waste Storage Area No. 6 at the Oak Ridge National Laboratory. The drain was designed to hydrologically isolate a 0.44-ha area that contains a group of 49 low-level waste trenches by separating it from upgradient groundwater recharge areas. The 252-m drain (maximum depth = 9 m) that surrounds the group of trenches on the north and east sides was excavated, lined with filter fabric, backfilled with crushed stone, and covered with a 0.6 m layer of excavated material at an estimated cost of $153,000. Of the 17 days it took to complete the work, about 5 days were spent excavating sidewall slide material that fell into the drain during excavation. Photography of the drain wall revealed the contorted structure of the weathered shale, which was responsible for many of the slides. Monitoring wells placed at intervals on the drain centerline indicate that groundwater is draining from the surrounding Maryville Formation (Conasauga Group); flows at catch basin No. 2 ranged from a base flow of 4 to 7 L/min to a maximum of 35 L/min, recorded on October 13. In response to groundwater flow in the drain, water levels in several monitoring wells adjacent to the drain have dropped by as much as 2.24 m to an elevation only slightly higher than the bottom of the French drain. In addition to the general lowering of the water table in the vicinity of the drain, water levels in three trenches began to subside, indicating that the drain is beginning to have an effect on the water in the trenches as well. Further monitoring of both drain discharge and water levels in monitoring wells across the site is continuing

  12. Water Table Recession in Subsurface Drained Soils

    OpenAIRE

    Moustafa, Mahmoud Mohamed; Yomota, Atsushi

    1999-01-01

    Theoretical drainage equations are intensively tested in many parts of humid and arid regions and are commonly used in drainage design. However, this is still a great concern in Japan as the drainage design is exclusively based on local experiences and empirical basis. There is a need therefore to evaluate the theoretical drainage equations under Japanese field conditions to recommend equations for design of subsurface drainage systems. This was the main motivation for this study. While drain...

  13. No-Drain Single Incision Liposuction Pull-Through Technique for Gynecomastia.

    Science.gov (United States)

    Khalil, Ashraf A; Ibrahim, Amr; Afifi, Ahmed M

    2017-04-01

    Several different methods have been proposed for treatment of gynecomastia, depending on the amount of breast enlargement and skin redundancy. The liposuction pull-through technique has been proposed as an efficacious treatment for many gynecomastia cases. This work aims to study the outcome of this technique when applied as an outpatient procedure, without the use of drains and through a single incision. Fifty-two patients with bilateral gynecomastia without significant skin excess were included in this study. The liposuction pull-through technique was performed through a single incision just above the inframammary fold and without the use of drains. Patients were followed up for 6 months. The proposed technique was able to treat the gynecomastia in all patients, with a revision rate of 1.9% to remove residual glandular tissues. There were no seromas, hematomas, nipple distortion, permanent affection of nipple sensation or wound healing problems. The liposuction pull-through technique is an effective treatment for gynecomastia without significant skin redundancy. It combines the benefits of the direct excision of glandular tissues, with the minimally invasive nature of liposuction. Performing the procedure through a single incision without the use of drains and without general anesthesia is a safe alternative. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266 .

  14. Theoretical computation background for transformation of foundations using pile drains

    Directory of Open Access Journals (Sweden)

    Ter-Martirosyan Zaven

    2017-01-01

    Full Text Available In the design of foundations for buildings and structures of various purposes, including improved risk, weak water-saturated clay soils with low mechanical characteristics are often found on a construction site. One of the possible ways of using them as a foundation is to seal them in various ways, including using pile drains of sand or rock stone material that are capable of both absorbing the load at the base and accelerating the process of filtration consolidation. This paper describes an analytical solution to the problem of interaction between the pile and the mattress with the surrounding soil of the foundation, taking into account the possibility of expanding the pile shaft. Solutions are obtained for determining the stresses in the shaft of the pile drain and in the soil under the mattress. The solution takes into account the influence of the pre-stressed state of the foundation after compaction on the formation of a stress-strain state during the erection and operation of structures. The solutions are relevant for consolidating pile drains made of rubble or for jet grouting piles, the rigidity of which is comparable to the rigidity of the surrounding soil. The paper describes the technique for determining the characteristics of the strength and deformability of the converted foundation and the results of large-scale tests at the experimental site for the construction of a large energy facility in Russia.

  15. 40 CFR 63.136 - Process wastewater provisions-individual drain systems.

    Science.gov (United States)

    2010-07-01

    ... restricts wind motion across the open area between the pipe and the drain) that encloses the space between...., there is no pump) or is operated with no more than slight fluctuations in the liquid level, the owner or...

  16. An Improvised Active Drain | Ogirima | Nigerian Journal of Surgical ...

    African Journals Online (AJOL)

    An improvised active drain is designed from intravenous infusion set and recycled RedivacR or Haemovac® bottle. Outcome of the use of this system on 100 patients is presented. This suction drainage system had been used in major orthopaedic and common minor surgical procedures and no significant complication was ...

  17. On the use of drains in orthopedic and trauma

    African Journals Online (AJOL)

    2013-11-08

    Nov 8, 2013 ... Even major procedures like total knee and arthroplasties are being performed without drains. We set to find ... discourage wound healing while encouraging bacterial ... a period of two days or if drainage over the first twenty‑four hours was found ... Three of the twenty Kuntscher nailings for femoral fracture.

  18. Skyrmion based universal memory operated by electric current

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Jiadong; Chien, Chia-Ling; Li, Yufan; Lake, Roger K.; Yin, Gen

    2017-09-26

    A method for generating a skyrmion, comprising: depositing a vertical metallic nanopillar electrode on a first side of a helimagnetic thin film, the helimagnetic thin film having a contact on a second side to provide a current drain; injecting a current through the vertical metallic nanopillar electrode to generate a rotating field; and applying a static upward magnetic field perpendicular to the helimagnetic thin film to maintain an FM phase background.

  19. Systematic review and meta-analysis of wound drains after thyroid surgery.

    LENUS (Irish Health Repository)

    Woods, R S R

    2014-04-01

    Drainage after routine thyroid and parathyroid surgery remains controversial. However, there is increasing evidence from a number of randomized clinical trials (RCTs) suggesting no benefit from the use of drains.

  20. India: 'brain drain' or the migration of talent?

    Science.gov (United States)

    Oommen, T K

    1989-09-01

    2 views on "brain drain" exist: 1) LDCs lose their enormous investments on higher education when skilled people migrate to other countries and 2) LDCs are exaggerating the problem and only a few skilled people migrate at 1 time. India does not completely lose its investment in education when professionals migrate, since the migrants still contribute to knowledge and also send remittances to relatives in India. Unemployed educated people would cause a greater drain on India's resources than educated migrants. The author prefers the phrase migration of talent to brain drain, since the former indicates a 2-way movement. Most migrants from LDCs are students. About 11,000 university graduates leave India every year for advanced study and/or work. A conservative estimate is that 2500 will remain abroad permanently. Most professionals who migrate go to the US and Canada. Factors promoting migration include 1) unemployment, 2) immigration rules, 3) colonial links, 4) financial incentives and material benefits, 5) pursuit of higher education, 6) improvement of working conditions and facilities, 7) avoidance of excessive bureaucratic procedures, and 8) compensation for the mismatch between Indian education and employment. Reasons for returning to India include 1) deference to wives who were unable to adjust to a foreign way of life, 2) contributing to Indian development, and 3) racial discrimination. It will probably not be possible to lure back migrants who left for material reasons. Attractive job offers could entice back those who left for advanced training. To encourage the return of those who left to pursue high quality research, India must 1) increase expenditure on research and development, possibly through the private industrial sector, 2) promote travel to other countries for professional enrichment, and 3) improve conditions of research work. The article concludes with an analysis of migration of talent from 3 perspectives: 1) the individual, 2) the nation

  1. Remote sensing for assessing the zone of benefit where deep drains improve productivity of land affected by shallow saline groundwater.

    Science.gov (United States)

    Kobryn, H T; Lantzke, R; Bell, R; Admiraal, R

    2015-03-01

    The installation of deep drains is an engineering approach to remediate land salinised by the influence of shallow groundwater. It is a costly treatment and its economic viability is, in part, dependent on the lateral extent to which the drain increases biological productivity by lowering water tables and soil salinity (referred to as the drains' zone of benefit). Such zones may be determined by assessing the biological productivity response of adjacent vegetation over time. We tested a multi-temporal satellite remote sensing method to analyse temporal and spatial changes in vegetation condition surrounding deep drainage sites at five locations in the Western Australian wheatbelt affected by dryland salinity-Morawa, Pithara, Beacon, Narembeen and Dumbleyung. Vegetation condition as a surrogate for biological productivity was assessed by Normalised Difference Vegetation Index (NDVI) during the peak growing season. Analysis was at the site scale within a 1000 m buffer zone from the drains. There was clear evidence of NDVI increasing with elevation, slope and distance from the drain. After accounting for elevation, slope and distance from the drain, there was a significant increase in NDVI across the five locations after installation of deep drains. Changes in NDVI after drainage were broadly consistent with measured changes at each site in groundwater levels after installation of the deep drains. However, this study assessed the lateral extent of benefit for biological productivity and gave a measure of the area of benefit along the entire length of the drain. The method demonstrated the utility of spring NDVI images for rapid and relatively simple assessment of the change in site condition after implementation of drainage, but approaches for further improvement of the procedure were identified. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. An analytical turn-on power loss model for 650-V GaN eHEMTs

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Shen, Zhan

    2018-01-01

    This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time-d......-domain solutions to the drain-source voltage and drain current are obtained. Finally, double-pulse tests are conducted to verify the proposed power loss model. This analytical model enables an accurate and fast switching behavior characterization and power loss prediction.......This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time...

  3. A COMPARATIVE STUDY IN HERNIOPLASTY WITH AND WITHOUT DRAIN AND THE ASSOCIATED COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Amruthavalli Bayya Venkatesulu

    2017-03-01

    Full Text Available BACKGROUND The present study is a comparative study to compare in Lichtenstein’s mesh repair, the need of a subcutaneous suction drain in inguinal hernias at Government General Hospital, Guntur. To study the advantages and disadvantages of using subcutaneous suction drain in Lichtenstein’s hernioplasty. MATERIALS AND METHODS In the present study, out of 50 patients,32% of patients who had undergone drainage group complained of pain and 8% of patients who had undergone non-drainage complained of pain. In our study, 0% and 4% of patients developed haematoma in drainage and non-drainage group, respectively. 12% of patients in drainage group developed seroma and 12% of patients in non-drainage group developed seroma. In the present study, 16% of cases in drainage and 20% in non-drainage group. In the present study, patients in drainage group mean postoperative hospital stay is 9.1 days and in non-drainage group is 6.7 days. The average duration of postoperative hospital stay in patients of drainage group is higher than in non-drainage group with the above results, the early postoperative complications like pain, mean postoperative stay in hospital are increased in Lichtenstein’s with drainage group. The early postoperative complications like seroma, haematoma and wound infection rates are similar in both drainage and non-drainage groups. So, it appears that suction drain usage can be restricted in Lichtenstein’s tension free mesh repair in simple inguinal hernias unless the hernia is complicated or there is extensive dissection. RESULTS The details of all the (50 cases were drawn as master chart with regard of relevance. Statistical analysis was done using Epi info version 3.5.3. P value is calculated using Chi-square test. CONCLUSION In the present study, 50 patients with inguinal hernia who had undergone Lichtenstein’s hernioplasty with subcutaneous suction drain are compared with those who had undergone Lichtenstein’s hernioplasty

  4. Students’ mental model in electric current

    Science.gov (United States)

    Pramesti, Y. S.; Setyowidodo, I.

    2018-05-01

    Electricity is one of essential topic in learning physics. This topic was studied in elementary until university level. Although electricity was related to our daily activities, but it doesn’t ensure that students have the correct concept. The aim of this research was to investigate and then categorized the students’ mental model. Subject consisted of 59 students of mechanical engineering that studied Physics for Engineering. This study was used a qualitative approach that used in this research is phenomenology. Data were analyzed qualitatively by using pre-test, post-test, and investigation for discovering further information. Three models were reported, showing a pattern which related to individual way of thinking about electric current. The mental model that was discovered in this research are: 1) electric current as a flow; 2) electric current as a source of energy, 3) electric current as a moving charge.

  5. Effect of One versus Two Drain Insertion on Postoperative Seroma Formation after Modified Radical Mastectomy

    Directory of Open Access Journals (Sweden)

    farzaneh ebrahimifard

    2016-04-01

    Full Text Available Background: Modified radical mastectomy (MRM is still one of globally accepted surgical techniques for breast cancer and in some selected patient is the gold standard type of surgery. The most frequent complication of this procedure is seroma under skin flaps or in the axilla as reported as much as 30% in some studies. The use of closed suction drainage system to reduce the incidence of this complication has been routinely accepted by surgeons; however, length of catheter stay and the number of catheters inserted in the wound are still controversial. The present study compares the results of single versus double drain insertion in patients undergoing MRM for breast cancer.Materials and Methods: The study was conducted on 100 women with breast cancer who were candidate for MRM surgery during 2007-2010 referred to Modarres hospital, Tehran, Iran as a randomized group matched controlled trial.Results: There was no significant difference between the two groups in terms of age, BMI, and tumor weight (P=0.406 (Table 1. Similarly, the difference between the two groups was insignificant in tumor size (T and number of lymph nodes involved (P=0.145. There was no significant difference between the two groups in timing of axillary drain removal (P=0.064. No significant differences were observed between the two groups in mean aspirated fluid (P=0.071 and mean aspirated sera (P=0.484 after removal of drains.Conclusion: This study revealed one drain insertion in MRM surgery is as effective as two drain and probably less morbidity and cost.

  6. Indwelling pleural drain for mobile management of malignant pleural effusion-combining benefits of both methods

    OpenAIRE

    Dinesh Mehta; Anshu Gupta; Sameer Singhal; Sachin Bansal

    2015-01-01

    Malignant pleural effusion is a leading cause of morbidity in lung cancer patients requiring repeated pleural aspirations or persistent intercostal drainage tube. Using an indigenous method of putting icd tube of smaller size with subcutaneous tunneling would allow draining fluid from lungs easily and painlessly when needed and avoid the need for repeated injections and chest tube insertion every time the fluid is to be drained.

  7. Spatial and temporal distribution of mosquitoes in underground storm drain systems in Orange County, California.

    Science.gov (United States)

    Su, Tianyun; Webb, James P; Meyer, Richard P; Mulla, Mir S

    2003-06-01

    Underground storm drain systems in urban areas of Orange County include thousands of miles of gutters and underground pipelines, plus hundreds of thousands of catch basins and manhole chambers, all of which drain runoff water from residential, business and commercial establishments as well as highways and streets. These systems serve as major developmental and resting sites for anthropophilic and zoophilic mosquitoes. Investigations on spatial and temporal distribution of mosquitoes in these systems were conducted during November 1999 to October 2001. Immature mosquitoes were sampled by dipper or dipping net and adult mosquitoes by non-attractive CDC traps in manhole chambers, catch basins and a large drain. Culex quinquefasciatus Say prevailed at all 15 structures of the study in 4 cities of Orange County as the predominant species (> 99.9%). Larvae and pupae were present from April to October, peaking from May to September. The population density of adults was the lowest in February with 2 peaks of abundance occurring from May to July and from September to October. Manhole chambers and catch basins harbored more mosquitoes than did the large drain. Minimum and maximum temperatures during a 24 h sampling period was an important factor influencing adult mosquito activity and catches; more mosquitoes were caught in traps when it was warmer, especially when the minimum temperatures were higher. The proportion of females to males in general increased during winter and early spring an ddeclined during summer. The proportion of gravid females to empty females was higher during the winter than in summer. Other dipteran taxa such as psychodid moth flies and chironomid midges exhibited somewhat similar seasonal patterns as did mosquito populations. Average water temperature was relatively stable throughout the year, and water quality in underground drain systems was characterized by low dissolved oxygen, coupled with above normal electrical conductivity and salinity levels

  8. Brain Drain in Higher Education: Lost Hope or Opportunity?

    Science.gov (United States)

    Odhiambo, George

    2012-01-01

    The flight of human capital is a phenomenon that has been of concern to academics and development practitioners for decades but unfortunately, there is no systematic record of the number of skilled professionals that many African countries have continued to lose to the developed world. Termed the "brain drain", it represents the loss of…

  9. The Treatment Of The RSU In Controlled Drains: Their Sanitary Problem To The Production Of Energy

    International Nuclear Information System (INIS)

    Calderon U, Rafael A.

    1995-01-01

    The limitless world production of residuals generates constant concerns with relationship to its administration. The classic elimination methods as the drains controlled in front of the controversial incineration plants and gasification as well as the expectations created around the recycle practices, are reason of intense debates among city councils, specialist, environmentalist technicians and the public in general. The certain thing is that the residuals in the last 30 years have been valued economically. Today in day the residuals are appreciated by certain sectors that begin to monopolize the line of the recycle because they come them an excellent business. All the methods of elimination of residuals produce in turn others. Those of solid nature in general go to the drain, the semi-liquids becomes dehydrated for the same end. Presently work, without seeking to say that the employment of the drains is the best option, thinks about how it has more than enough they are possible to optimize its use. Showing beside their eminently sanitary vocation an energy alternative that allows the use of the combustible gas that is generated in them. An added value that is interesting if this it becomes source of well-being for social excluded nuclei and economically like it happens for example in the peripheries of the drains of the big Latin American cities. They are considered which are the main aspects that intervene in the generation, production and quality of the gas methane of the drains. Their reception methods and their use alternatives. Lastly emphasis is made in the environmental situation to European and international level about the gases of the drain, how it thinks about the topic of the greenhouse effect and which are the actions for the horizon of the year 2000. They are related some experiences in Europe on the use of the biogas

  10. Origin of Degradation Phenomenon under Drain Bias Stress for Oxide Thin Film Transistors using IGZO and IGO Channel Layers

    OpenAIRE

    Bak, Jun Yong; Kang, Youngho; Yang, Shinhyuk; Ryu, Ho-Jun; Hwang, Chi-Sun; Han, Seungwu; Yoon, Sung-Min

    2015-01-01

    Top-gate structured thin film transistors (TFTs) using In-Ga-Zn-O (IGZO) and In-Ga-O (IGO) channel compositions were investigated to reveal a feasible origin for degradation phenomenon under drain bias stress (DBS). DBS-driven instability in terms of VTH shift, deviation of the SS value, and increase in the on-state current were detected only for the IGZO-TFT, in contrast to the IGO-TFT, which did not demonstrate VTH shift. These behaviors were visually confirmed via nanoscale transmission el...

  11. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    Directory of Open Access Journals (Sweden)

    Xiao Guo

    2014-01-01

    Full Text Available This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1 the flow with the threshold gradient would not occur instantaneously throughout the whole unit cell. Rather, it gradually occurs from the vertical drain to the outside; (2 the moving boundary would never reach the outer radius of influence if R+1

  12. Storm-time ring current: model-dependent results

    Directory of Open Access Journals (Sweden)

    N. Yu. Ganushkina

    2012-01-01

    Full Text Available The main point of the paper is to investigate how much the modeled ring current depends on the representations of magnetic and electric fields and boundary conditions used in simulations. Two storm events, one moderate (SymH minimum of −120 nT on 6–7 November 1997 and one intense (SymH minimum of −230 nT on 21–22 October 1999, are modeled. A rather simple ring current model is employed, namely, the Inner Magnetosphere Particle Transport and Acceleration model (IMPTAM, in order to make the results most evident. Four different magnetic field and two electric field representations and four boundary conditions are used. We find that different combinations of the magnetic and electric field configurations and boundary conditions result in very different modeled ring current, and, therefore, the physical conclusions based on simulation results can differ significantly. A time-dependent boundary outside of 6.6 RE gives a possibility to take into account the particles in the transition region (between dipole and stretched field lines forming partial ring current and near-Earth tail current in that region. Calculating the model SymH* by Biot-Savart's law instead of the widely used Dessler-Parker-Sckopke (DPS relation gives larger and more realistic values, since the currents are calculated in the regions with nondipolar magnetic field. Therefore, the boundary location and the method of SymH* calculation are of key importance for ring current data-model comparisons to be correctly interpreted.

  13. Effect of Needle Aspiration of Pneumothorax on Subsequent Chest Drain Insertion in Newborns

    DEFF Research Database (Denmark)

    Murphy, Madeleine C; Heiring, Christian; Doglioni, Nicoletta

    2018-01-01

    Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating pneumotho......Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating...... was 5 tertiary European neonatal intensive care units. Infants receiving respiratory support (endotracheal ventilation, continuous positive airway pressure, or supplemental oxygen >40%) who had a pneumothorax on CR that clinicians deemed needed treatment were eligible for inclusion. Interventions...... was inserted if clinicians deemed that the response was inadequate. For CD insertion, a drain was inserted between the ribs and was left in situ. Main Outcomes and Measures: The primary outcome was whether a CD was inserted on the side of the pneumothorax within 6 hours of diagnosis. Results: A total of 76...

  14. The project of the technological line of the electronic-beam drains disinfection in the infected hospitals' divisions and tubercular centres

    International Nuclear Information System (INIS)

    Shlapatska, V.V.; Volkonsky, V.G.; Sakhno, V.I.; Tomchaj, S.P.

    1999-01-01

    The purpose of the project was to create the electrophysical facility for the environmental protection from contamination by drains of the infected hospitals' divisions and tubercular centres and prevention of open water reservoirs. Development of the economically approved methods of the radiative disinfection of contaminated drains; development of the inexpensive compact facility for the electron-beam disinfection of small volume drains

  15. Moving Policy Forward: "Brain Drain" as a Wicked Problem

    Science.gov (United States)

    Logue, Danielle

    2009-01-01

    The mobility of scientists and the concerns surrounding "brain drain" are not new. Even in the Ptolemic dynasty, the first king set out to attract and influence the movements of scholars to shift the centre of learning from Athens to Alexandria. Yet after all this time, there is still much policy discourse and debate focused on attempting to…

  16. Brain drain from developing countries: how can brain drain be converted into wisdom gain?

    Science.gov (United States)

    Dodani, Sunita; LaPorte, Ronald E

    2005-01-01

    Brain drain is defined as the migration of health personnel in search of the better standard of living and quality of life, higher salaries, access to advanced technology and more stable political conditions in different places worldwide. This migration of health professionals for better opportunities, both within countries and across international borders, is of growing concern worldwide because of its impact on health systems in developing countries. Why do talented people leave their countries and go abroad? What are the consequences of such migrations especially on the educational sector? What policies can be adopted to stem such movements from developing countries to developed countries? This article seeks to raise questions, identify key issues and provide solutions which would enable immigrant health professionals to share their knowledge, skills and innovative capacities and thereby enhancing the economic development of their countries. PMID:16260795

  17. Conjunctivodacryocystorhinostomy using a high-density porous polyethylene-coated tear drain tube.

    Science.gov (United States)

    Pushker, Neelam; Khurana, Saurbhi; Shrey, Dinesh; Bajaj, Mandeep S; Chawla, Bhavna; Chandra, Mahesh

    2013-08-01

    To evaluate the outcome of conjunctivodacryocystorhinostomy using a high-density porous polyethylene (HDPP)-coated tear drain tube. Patients with epiphora due to a proximal lacrimal system block were included in a prospective interventional case study. A total of 22 eyes were treated with lacrimal bypass surgery using the HDPP-coated tube. On follow-up (12-41 months), 21 eyes had a patent well-positioned tube with subjective relief of epiphora. In one eye, a loose sleeve was noted during surgery. The tube dislodged postoperatively and was removed. A high success rate with only a few minor complications is achievable using a HDPP-coated tear drain tube for lacrimal bypass surgery. Long-term follow-up is required to look for tube blockage due to conjunctival or nasal mucosal overgrowth.

  18. Pontine infarction caused by medial branch injury of the basilar artery as a rare complication of cisternal drain placement

    OpenAIRE

    Horiuchi, Tetsuyoshi; Yamamoto, Yasunaga; Kuroiwa, Masafumi; Rahmah, Nunung Nur; Hongo, Kazuhiro

    2012-01-01

    We present a rare complication of cisternal drain placement during aneurysm surgery. A ruptured anterior communicating artery aneurysm was clipped through a right pterional approach. A cisternal drain was inserted from the retro-carotid to the prepontine cistern. Postoperatively, a left-sided paresis of the upper extremity had developed. A CT brain scan revealed that the drain was located between the pons and the basilar artery, resulting in a pontine infarction. Vascular neurosurgeons should...

  19. Indwelling pleural drain for mobile management of malignant pleural effusion-combining benefits of both methods

    Directory of Open Access Journals (Sweden)

    Dinesh Mehta

    2015-01-01

    Full Text Available Malignant pleural effusion is a leading cause of morbidity in lung cancer patients requiring repeated pleural aspirations or persistent intercostal drainage tube. Using an indigenous method of putting icd tube of smaller size with subcutaneous tunneling would allow draining fluid from lungs easily and painlessly when needed and avoid the need for repeated injections and chest tube insertion every time the fluid is to be drained.

  20. A physics-based potential and electric field model of a nanoscale ...

    Indian Academy of Sciences (India)

    ... paper, we have developed a physics-based model for surface potential, channel potential, electric field and drain current for AlGaN/GaN high electron mobility transistor with high-K gate dielectric using two-dimensional Poisson equation under full depletion approximation with the inclusion of effect of polarization charges.

  1. Drive Current Enhancement in TFET by Dual Source Region

    Directory of Open Access Journals (Sweden)

    Zhi Jiang

    2015-01-01

    Full Text Available This paper presents tunneling field-effect transistor (TFET with dual source regions. It explores the physics of drive current enhancement. The novel approach of dual source provides an effective technique for enhancing the drive current. It is found that this structure can offer four tunneling junctions by increasing a source region. Meanwhile, the dual source structure does not influence the excellent features of threshold slope (SS of TFET. The number of the electrons and holes would be doubled by going through the tunneling junctions on the original basis. The overlap length of gate-source is also studied. The dependence of gate-drain capacitance Cgd and gate-source capacitance Cgs on gate-to-source voltage Vgs and drain-to-source voltage Vds was further investigated. There are simulation setups and methodology used for the dual source TFET (DS-TFET assessment, including delay time, total energy per operation, and energy-delay product. It is confirmed that the proposed TFET has strong potentials for VLSI.

  2. Evaluation of the hooghoudt and kirkham tile drain equations in the soil and water assessment tool to simulate tile flow and nitrate-nitrogen.

    Science.gov (United States)

    Moriasi, Daniel N; Gowda, Prasanna H; Arnold, Jeffrey G; Mulla, David J; Ale, Srinivasulu; Steiner, Jean L; Tomer, Mark D

    2013-11-01

    Subsurface tile drains in agricultural systems of the midwestern United States are a major contributor of nitrate-N (NO-N) loadings to hypoxic conditions in the Gulf of Mexico. Hydrologic and water quality models, such as the Soil and Water Assessment Tool, are widely used to simulate tile drainage systems. The Hooghoudt and Kirkham tile drain equations in the Soil and Water Assessment Tool have not been rigorously tested for predicting tile flow and the corresponding NO-N losses. In this study, long-term (1983-1996) monitoring plot data from southern Minnesota were used to evaluate the SWAT version 2009 revision 531 (hereafter referred to as SWAT) model for accurately estimating subsurface tile drain flows and associated NO-N losses. A retention parameter adjustment factor was incorporated to account for the effects of tile drainage and slope changes on the computation of surface runoff using the curve number method (hereafter referred to as Revised SWAT). The SWAT and Revised SWAT models were calibrated and validated for tile flow and associated NO-N losses. Results indicated that, on average, Revised SWAT predicted monthly tile flow and associated NO-N losses better than SWAT by 48 and 28%, respectively. For the calibration period, the Revised SWAT model simulated tile flow and NO-N losses within 4 and 1% of the observed data, respectively. For the validation period, it simulated tile flow and NO-N losses within 8 and 2%, respectively, of the observed values. Therefore, the Revised SWAT model is expected to provide more accurate simulation of the effectiveness of tile drainage and NO-N management practices. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  3. Case Report: Supernumerary right renal vein draining inferior to the ...

    African Journals Online (AJOL)

    With recent increase in renal transplantations, renovascular reconstructions and imaging advances, meticulous knowledge of the normal and variant anatomy of the renal vasculature is important to avoid potential pitfalls. We report a case of an accessory renal vein arising from the right kidney, and draining into the inferior ...

  4. Influence of Hudiara Drain Water Irrigation on Trace Elements Load ...

    African Journals Online (AJOL)

    ... Drain Water Irrigation on Trace Elements Load In Soil And Uptake By Vegetables. ... This polluted water not only contains organic matter and crop nutrients but also ... Plant samples were collected at maturity from all the monitoring points. ... (DO), Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD) ...

  5. A prospective randomised study to compare the utility and outcomes of subdural and subperiosteal drains for the treatment of chronic subdural haematoma.

    LENUS (Irish Health Repository)

    Kaliaperumal, Chandrasekaran

    2012-11-01

    The usage of a drain following evacuation of a chronic subdural haematoma (CSDH) is known to reduce recurrence. In this study we aim to compare the clinical outcomes and recurrence rate of utilising two different types of drains (subperiosteal and subdural drain) following drainage of a CSDH.

  6. Current density and continuity in discretized models

    International Nuclear Information System (INIS)

    Boykin, Timothy B; Luisier, Mathieu; Klimeck, Gerhard

    2010-01-01

    Discrete approaches have long been used in numerical modelling of physical systems in both research and teaching. Discrete versions of the Schroedinger equation employing either one or several basis functions per mesh point are often used by senior undergraduates and beginning graduate students in computational physics projects. In studying discrete models, students can encounter conceptual difficulties with the representation of the current and its divergence because different finite-difference expressions, all of which reduce to the current density in the continuous limit, measure different physical quantities. Understanding these different discrete currents is essential and requires a careful analysis of the current operator, the divergence of the current and the continuity equation. Here we develop point forms of the current and its divergence valid for an arbitrary mesh and basis. We show that in discrete models currents exist only along lines joining atomic sites (or mesh points). Using these results, we derive a discrete analogue of the divergence theorem and demonstrate probability conservation in a purely localized-basis approach.

  7. A physics-based potential and electric field model of a nanoscale ...

    Indian Academy of Sciences (India)

    In this paper, we have developed a physics-based model for surface potential, channel potential, electric field and drain current for AlGaN/GaN high electron mobility transistor with high-K gate dielectric using two-dimensional Poisson equation under full depletion approximation with the inclusion of effect of polarization ...

  8. Dissolved organic nitrogen (DON) losses from nested artificially drained lowland catchments with contrasting soil types

    Science.gov (United States)

    Tiemeyer, Bärbel; Kahle, Petra; Lennartz, Bernd

    2010-05-01

    Artificial drainage is a common practice to improve moisture and aeration conditions of agricultural land. It shortens the residence time of water in the soil and may therefore contribute to the degradation of peatlands as well as to the still elevated level of diffuse pollution of surface water bodies, particularly if flow anomalies like preferential flow cause a further acceleration of water and solute fluxes. Especially in the case of nitrate, artificially drained sub-catchments are found to control the catchment-scale nitrate losses. However, it is frequently found that nitrate losses and nitrogen field balances do not match. At the same time, organic fertilizers are commonly applied and, especially in lowland catchments, organic soils have been drained for agricultural use. Thus, the question arises whether dissolved organic nitrogen (DON) forms an important component of the nitrogen losses from artificially drained catchments. However, in contrast to nitrate and even to dissolved organic carbon (DOC), this component is frequently overlooked, especially in nested catchment studies with different soil types and variable land use. Here, we will present data from a hierarchical water quantity and quality measurement programme in the federal state Mecklenburg-Vorpommern (North-Eastern Germany). The monitoring programme in the pleistocene lowland catchment comprises automatic sampling stations at a collector drain outlet (4.2 ha catchment), at a ditch draining arable land on mineral soils (179 ha), at a ditch mainly draining grassland on organic soils (85 ha) and at a brook with a small rural catchment (15.5 km²) of mixed land use and soil types. At all sampling stations, daily to weekly composite samples were taken, while the discharge and the meteorological data were recorded continuously. Water samples were analyzed for nitrate-nitrogen, ammonium-nitrogen and total nitrogen. We will compare two years: 2006/07 was a very wet year (P = 934 mm) with a high summer

  9. Filling, storing and draining. Three key aspects of landslide hydrology

    Science.gov (United States)

    Bogaard, Thom; Greco, Roberto

    2016-04-01

    Rainfall-triggered landslides are among the most widespread hazards in the world. The hydrology in and around a landslide area is key to pore pressure build-up in the soil skeleton which reduces shear strength due to the buoyancy force exerted by water in a saturated soil and to soil suction in an unsaturated soil. Extraordinary precipitation events trigger most of the landslides, but, at the same time, the vast majority of slopes do not fail. The intriguing question is: 'When and where exactly can a slope become triggered to slide and flow downwards?' The objective of this article is to present and discuss landslide hydrology at three scales - pore, hillslope, and catchment - which, taken together, give an overview of this interdisciplinary science. In fact, for rainfall-triggered landslides to occur, an unfavourable hydrological interplay should exist between fast and/or prolonged infiltration, and a relatively 'slow' drainage. The competition of water storage, pressure build-up and the subsequently induced drainage contains the importance of the timing, which is indisputably one of the more delicate but relevant aspects of landslide modelling, the overlay of hydrological processes with different time scales. As slopes generally remain stable, we can argue that effective drainage mechanisms spontaneously develop, as the best for a slope to stay stable is getting rid of the overload of water (above field capacity), either vertically or laterally. So, landslide hydrology could be framed as 'Filling-Storing-Draining'. Obviously, 'Storing' is added to stress the importance of dynamic pressure build-up for slope stability. 'Draining' includes all removal of water from the system (vertical and lateral flow, evaporation and transpiration) and thus pore water pressure release. Furthermore, by addressing landslide hydrology from both earth sciences and soil mechanics perspectives, we aim to manifest the hydrological processes in hillslopes and their influence on behaviour

  10. Hydrobiogeochemical interactions in 'anoxic' limestone drains for neutralization of acidic mine drainage

    Science.gov (United States)

    Robbins, E.I.; Cravotta, C.A.; Savela, C.E.; Nord, G.L.

    1999-01-01

    Processes affecting neutralization of acidic coal mine drainage were evaluated within 'anoxic' limestone drains (ALDs). Influents had pH???3.5 and dissolved oxygen Al3+ and Fe3+ compounds. Cleavage mounts of calcite and gypsum that were suspended within the ALDs and later examined microscopically showed dissolution features despite coatings by numerous bacteria, biofilms, and Fe-Al-Si precipitates. In the drain exhibiting the greatest flow reduction, Al-hydroxysulfates had accumulated on limestone surfaces and calcite etch points, thus causing the decline in transmissivity and dissolution. Therefore, where Al loadings are high and flow rates are low, a pre-treatment step is indicated to promote Al removal before diverting acidic mine water into alkalinity-producing materials. ?? 1998 Elsevier Science Ltd.

  11. A questionnaire about radiation safety management of the draining-water system at nuclear medicine facilities

    International Nuclear Information System (INIS)

    Shizukuishi, Kazuya; Narita, Hiroto

    2004-01-01

    We conducted a questionnaire survey about radiation-safety management condition in Japanese nuclear medicine facilities to make materials of proposition for more reasonable management of medical radioactive waste. We distributed a questionnaire to institutions equipped with Nuclear Medicine facilities. Of 1,125 institutions, 642 institutes (52.8%) returned effective answers. The questionnaire covered the following areas: scale of an institution, presence of enforcement of radiotherapy, system of a tank, size and number of each tank, a form of draining-water system, a displacement in a radioactive rays management area, a measurement method of the concentration of medical radioactive waste in draining water system, planned and used quantity of radioisotopes for medical examination and treatment, an average displacement of hospital for one month. In most institutions, a ratio of dose limitation of radioisotope in draining-water system was less than 1.0, defined as an upper limitation in ordinance. In 499 hospitals without facilities of hospitalization for unsealed radioisotope therapy, 473 hospitals reported that sum of ratios of dose limits in a draining-water system was less than 1.0. It was calculated by used dose of radioisotope and monthly displacement from hospital, on the premise that all used radioisotope entered in the general draining-water system. When a drainage including radioactivity from a controlled area join with that from other area before it flows out of a institution, it may be diluted and its radioactive concentration should be less than its upper limitation defined in the rule. Especially, in all institutions with a monthly displacement of more than 25,000 m 3 , the sum of ratio of the concentration of each radionuclide to the concentration limit dose calculated by used dose of radioisotope, indicated less than 1.0. (author)

  12. Investigation of the effects of slow-release fertilizer and struvite in biodegradation in filter drains and potential application of treated water in irrigation of road verges.

    Science.gov (United States)

    Theophilus, Stephen C; Mbanaso, Fredrick U; Nnadi, Ernest O; Onyedeke, Kingsley T

    2017-11-14

    Filter drains are usually laid along the margins of highways. Highway runoffs are polluted with hydrocarbons and high levels of total dissolved solids. Therefore, effective pollution removal mechanism is necessary in order to avoid contamination of surrounding soils and groundwater. Biodegradation is amongst pollution removal mechanisms in filter drains, but it is a relatively slow process which is dependent on wide range of factors including the type of pollutant and availability of nutrients. This paper reports on a study conducted to investigate the impact of slow-release fertilizer and struvite in enhancement of biodegradation of hydrocarbon in filter drains. Filter drain models incorporated with geotextile were challenged with cumulative oil loading of 178 mg/m 2 /week with a view to comparing the efficiency of these two nutrient sources under high oil pollution loading and realistic rainfall conditions of 13 mm/week. Nutrients and street dust were applied at one-off rate of 17 g/m 2 and 1.55 g/rig to provide nutrient enhancement and simulate field conditions respectively. The impact of the nutrients was studied by monitoring bacterial and fungal growth using nutrient agar, Rose Bengal Agar media and CO2 evolution. EC, pH, heavy metals, TPH, elemental analysis and SAR were used to investigate water quality of effluent of filter drains for potential application as irrigation fluid for trees and flowers planted on road verges. The results show that nutrient application encouraged microbial activities and enhanced biodegradation rates with differences in type of nutrient applied. Also, it was observed that incorporation of geotextiles in filter drains improved pollution retention efficiency and there is a potential opportunity for utilization of struvite in SuDS systems as sustainable nutrient source.

  13. Quantity and quality of phosphorus losses from an artificially drained lowland catchment

    Science.gov (United States)

    Nausch, Monika; Woelk, Jana; Kahle, Petra; Nausch, Günther; Leipe, Thomas; Lennartz, Bernd

    2017-04-01

    Currently, agricultural diffuse sources constitute the major portion of phosphorus (P) fluxes to the Baltic Sea and have to reach the good ecological status aimed by the Baltic Sea Action Plan and the Marine Strategy Framework Directive. The objective of this study was to uncover the change in phosphorus loading as well as in P fractions along the flow path of a mid-size river basin in order to derive risk assessment and management strategies for a sustainable P reduction. P-fractions and the mineral composition of particulate P were investigated in a sub-basin of the river Warnow, the second largest German catchment discharging to the Baltic Sea. Samples were collected from the sources (tile drain, ditch) and along the subsequent brook up to the river Warnow representing spatial scales of a few hectars up to 3300 km2. The investigations were performed during the discharge season from November 1th 2013 until April 30th 2014 covering a relative dry and mild winter period. We observed an increase of total phosphorus (TP) concentrations from 15.5 ± 3.9 µg L-1 in the drain outlet to 72.0 ± 7.2 µg L-1 in the river Warnow emphasizing the importance of sediment-bound P mobilization along the flow path. Particulate phosphorus (PP) of 36.6 - 61.2% accounted for the largest share of TP in the streams. Clay minerals and Fe(hydr)oxides were the main carrier of particle bound P followed by apatite. A transformation of dissolved inorganic phosphorus (DIP) into particulate organic P was observed in the river Warnow with the beginning of the growth season in February. Our investigations indicate that the overall P load could be reduced by half when PP is removed.

  14. On the theoretical–numerical study of the ITER Upper Port Plug structure hydraulic behaviour under steady state and draining and drying transient conditions

    International Nuclear Information System (INIS)

    Di Maio, P.A.; Paradiso, D.; Dell’Orco, G.; Pitcher, C.S.; Kalish, M.

    2011-01-01

    Highlights: ► UPP TS hydraulic behaviour has been investigated under steady state and D and D transient conditions. ► A thermal–hydraulic system code has been adopted and a UPP TS model has been set-up and validated against results of steady state CFD analyses. ► The TS steady state hydraulic characteristic functions have been derived for two coolant flow paths showing that right plate inlet one is the most promising. ► Draining simulations indicate that the 4 MPa injection pressure is high enough to drain almost completely the circuit in a reasonable time (∼6 s). ► Results indicate that right plate inlet flow path allows the TS complete draining, eliminating the need for the drying procedure. - Abstract: The ITER diagnostic Upper Port Plug (UPP) is a water-cooled stainless steel structure aimed to integrate within vacuum vessel the plasma diagnostic systems, shielding them from neutron and photon irradiation. Due to the very intense heat loads expected, a proper cooling circuit has been designed to ensure an adequate UPP cooling with an acceptable thermal rise and an unduly high pumping power and to perform its draining and drying procedure by injection of pressurized nitrogen. A theoretical research activity has been launched at the Department of Nuclear Engineering of the University of Palermo aiming to investigate the hydraulic behaviour of the UPP Trapezoid Section cooling circuit under steady state conditions and during its draining and drying transient procedure. The research activity has been performed following a theoretical–computational approach and adopting the RELAP5 thermal–hydraulic system code. The Trapezoid Section cooling circuit characteristic functions have been derived under steady state conditions at various coolant temperatures for both the coolant flow paths at the present under consideration for this circuit. The distributions of coolant mass flow rates along the channels of the cooling circuit have been calculated too

  15. Assessment of Global Variability in UTBB MOSFETs in Subthreshold Regime

    Directory of Open Access Journals (Sweden)

    Sergej Makovejev

    2014-07-01

    Full Text Available The global variability of ultra-thin body and buried oxide (UTBB MOSFETs in subthreshold and off regimes of operation is analyzed. The variability of the off-state drain current, subthreshold slope, drain-induced barrier lowering (DIBL, gate leakage current, threshold voltage and their correlations are considered. Two threshold voltage extraction techniques were used. It is shown that the transconductance over drain current (gm/Id method is preferable for variability studies. It is demonstrated that the subthreshold drain current variability in short channel devices cannot be described by threshold voltage variability. It is suggested to include the effective body factor incorporating short channel effects in order to properly model the subthreshold drain current variability.

  16. Ditches and Drainage Structures, Culverts - cross drains were collected using a GPS for drainage basin project. Ditches are planned for the future., Published in 2005, 1:2400 (1in=200ft) scale, Effingham County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Ditches and Drainage Structures dataset current as of 2005. Culverts - cross drains were collected using a GPS for drainage basin project. Ditches are planned for...

  17. The "brain drain" of health care workers: causes, solutions and the example of Jamaica.

    Science.gov (United States)

    Lofters, Aisha K

    2012-07-18

    Despite much media attention being given to the physician shortage in Canada in recent years, this shortage pales in comparison to that seen in many middle- and low-income countries. A major cause of the shortage in these countries is the migration of health care workers from developing to developed nations, a phenomenon known as the "brain drain". The loss of these workers is having devastating impacts globally, particularly in Sub-Saharan Africa and the Caribbean. Causes of the "brain drain" are numerous and include poor working conditions in poorer countries and active recruitment by richer countries. Jamaica has been one of the countries in the Caribbean hardest hit by mass migration of health care workers. The multiple dimensions of Jamaica's health worker "brain drain" illustrate both the complexity of the issues reviewed in this commentary, and the net loss for low- and middle-income countries. Creative and sustainable solutions to the problem are actively being sought globally, but will require commitment and support from all nations as well as from international funding bodies if meaningful impacts on health are to be realized.

  18. Brain Drain: A Child's Brain on Poverty. Poverty Fact Sheet

    Science.gov (United States)

    Damron, Neil

    2015-01-01

    "Brain Drain: A Child's Brain on Poverty," released in March 2015 and prepared by intern Neil Damron, explores the brain's basic anatomy and recent research findings suggesting that poverty affects the brain development of infants and young children and the potential lifelong effects of the changes. The sheet draws from a variety of…

  19. Relationship of bleeding complications and impairment of draining veins after α-n-butyl cyanoacrylate embolization of brain arteriovenous malformations

    International Nuclear Information System (INIS)

    Fang Bing; Wang Yirong; Li Tielin; Duan Chuanzhi; Wang Qiujing; Zhao Qingping

    2007-01-01

    Objective: To investigate the causes, consequences and management of injuries to the draining veins after embolization of brain arterioven0us malformations (BAVMs) with α-n-butyl cyanoacrylate (NBCA). Methods: The angiographic imaging data of 189 BAVMs patients who underwent NBCA embolization were studied retrospectively. The status of the draining veins before and after NBCA embolization was observed and compared. The intracerebral hemorrhage (ICH)complications and their relation to their angiographic features were analyzed. Results: Twenty-three patients out of 189 patients showed injuries to the draining venous system, including 10 low-grade injury, 6 moderate injury, and 7 high-grade injury. Six patients suffered from ICH after embolization, of whom 4 patients were due to injuries of the draining veins (2 moderate and 2 high-grade). In the 3 months follow-up evaluation of 4 patients with ICH, one died, one was in vegetative state, and the other two patients suffered from residual severe or minor (1 patient for each) permanent neurological deficits. Conclusion: Our findings suggest that injury of the draining veins is the major cause of ICH and may lead to serious consequences after embolization of BAVMs with NBCA. (authors)

  20. Thermally induced spin-dependent current based on Zigzag Germanene Nanoribbons

    Science.gov (United States)

    Majidi, Danial; Faez, Rahim

    2017-02-01

    In this paper, using first principle calculation and non-equilibrium Green's function, the thermally induced spin current in Hydrogen terminated Zigzag-edge Germanene Nanoribbon (ZGeNR-H) is investigated. In this model, because of the difference between the source and the drain temperature of ZGeNR device, the spin up and spin down currents flow in the opposite direction with two different threshold temperatures (Tth). Hence, a pure spin polarized current which belongs to spin down is obtained. It is shown that, for temperatures above the threshold temperature spin down current increases with the increasing temperature up to 75 K and then decreases. But spin up current rises steadily and in the high temperature we can obtain polarized spin up current. In addition, we show an acceptable spin current around the room temperature for ZGeNR. The transmission peaks in ZGeNR which are closer to the Fermi level rather than Zigzag Graphene Nanoribbon (ZGNRS) which causes ZGeNR to have spin current at higher temperatures. Finally, it is indicated that by tuning the back gate voltage, the spin current can be completely modulated and polarized. Simulation results verify the Zigzag Germanene Nanoribbon as a promising candidate for spin caloritronics devices, which can be applied in future low power consumption technology.

  1. Simulation of diode characteristics of carbon nanotube field-effect transistors with symmetric source and drain contacts

    KAUST Repository

    Li, Jingqi; Zhang, Xixiang

    2011-01-01

    The diode characteristics of carbon nanotube field-effect transistors (CNTFETs) with symmetric source and drain contacts have been experimentally found at zero gate voltage (Li J. et al., Appl. Phys. Lett., 92 (2008) 133111). We calculate this characteristic using a semiclassical method based on Schottky barrier transistor mechanism. The influences of metal work function, the diameter of the carbon nanotubes and the dielectric thickness on the rectification behavior have been studied. The calculation results show that the metal with a higher work function results in a better diode characteristics for a p-type CNTFET. For single-walled carbon nanotubes (SWNTs) with different band gaps, both forward current and reverse current increase with decreasing band gap, but the ratio of forward current to reverse current decreases with decreasing band gap. This result is well consistent with the experimental observations reported previously. The simulation of the dielectric thickness effect indicates that the thinner the dielectric layer, the better the rectification behavior. The CNTFETs without a bottom gate could not show the diode characteristics, which is consistent with the reported experimental observation. © 2011 Europhysics Letters Association.

  2. Simulation of diode characteristics of carbon nanotube field-effect transistors with symmetric source and drain contacts

    KAUST Repository

    Li, Jingqi

    2011-09-01

    The diode characteristics of carbon nanotube field-effect transistors (CNTFETs) with symmetric source and drain contacts have been experimentally found at zero gate voltage (Li J. et al., Appl. Phys. Lett., 92 (2008) 133111). We calculate this characteristic using a semiclassical method based on Schottky barrier transistor mechanism. The influences of metal work function, the diameter of the carbon nanotubes and the dielectric thickness on the rectification behavior have been studied. The calculation results show that the metal with a higher work function results in a better diode characteristics for a p-type CNTFET. For single-walled carbon nanotubes (SWNTs) with different band gaps, both forward current and reverse current increase with decreasing band gap, but the ratio of forward current to reverse current decreases with decreasing band gap. This result is well consistent with the experimental observations reported previously. The simulation of the dielectric thickness effect indicates that the thinner the dielectric layer, the better the rectification behavior. The CNTFETs without a bottom gate could not show the diode characteristics, which is consistent with the reported experimental observation. © 2011 Europhysics Letters Association.

  3. Assessment of the use of selected chemical and microbiological constituents as indicators of wastewater in curtain drains from home sewage-treatment systems in Medina County, Ohio

    Science.gov (United States)

    Dumouchelle, Denise H.

    2006-01-01

    Many home sewage-treatment systems (HSTS) in Ohio use curtain or perimeter drains to depress the level of the subsurface water in and around the systems. These drains could possibly intercept partially untreated wastewater and release potential pathogens to ground-water and surface-water bodies. The quality of water in curtain drains from two different HSTS designs in Medina County, Ohio, was investigated using several methods. Six evaporation-transpiration-absorption (ETA) and five leach-line (LL) systems were investigated by determining nutrient concentrations, chloride/bromide ratios (Cl/Br), Escherichia coli (E. coli ) concentrations, coliphage genotyping, and genetic fingerprinting of E. coli. Water samples were collected at 11 sites and included samples from curtain drains, septic tanks, and residential water wells. Nitrate concentrations in the curtain drains ranged from 0.03 to 3.53 mg/L (milligrams per liter), as N. Concentrations of chloride in 10 of the 11 curtain drains ranged from 5.5 to 21 mg/L; the chloride concentration in the eleventh curtain drain was 340 mg/L. Bromide concentrations in 11 curtain drains ranged from 0.01 to 0.22 mg/L. Cl/Br ratios ranged from 86 to 2,000. F-specific coliphage were not found in any curtain-drain samples. Concentrations of E. coli in the curtain drains ranged from 1 to 760 colonies per 100 milliliters. The curtain-drain water-quality data were evaluated to determine whether HSTS-derived water was present in the curtain drains. Nutrient concentrations were too low to be of use in the determination. The Cl/Br ratios appear promising. Coliphage was not detected in the curtain drains, so genotyping could not be attempted. E. coli concentrations in the curtain drains were all less than those from the corresponding HSTS; only one sample exceeded the Ohio secondary-contact water-quality standard. The genetic fingerprinting data were inconclusive because multiple links between unrelated sites were found. Although the

  4. Negative charging effect of traps on the gate leakage current of an AlGaN/GaN HEMT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. J.; Lim, J. H.; Yang, J. W. [Chonbuk National University, Jeonju (Korea, Republic of); Stanchina, W. [University of Pittsburgh, Pittsburgh, PA (United States)

    2014-08-15

    The negative charging effect of surface traps on the gate leakage current of AlGaN/GaN high electron mobility transistors (HEMTs) was investigated. The gate leakage current could be decreased by two orders of magnitude by using a photo-electrochemical process to treat of the source and the drain region, but current flowed into the gate even at a negative voltage in a limited region when the measurement was executed with a gate voltage sweep from negative to positive voltage. Also the electrical characteristics of the HEMT were degraded by pulsed operation of the gate. Traps newly generated on the surface were regarded as sources for the current that flowed against the applied voltage, and the number of traps was estimated. Also, a slow transient in the drain current was confirmed based on the results of delayed sweep measurements.

  5. Anisotropic Behaviour of Opalinus Clay Through Consolidated and Drained Triaxial Testing in Saturated Conditions

    Science.gov (United States)

    Favero, Valentina; Ferrari, Alessio; Laloui, Lyesse

    2018-05-01

    This paper investigates the anisotropic hydro-mechanical behaviour of Opalinus Clay shale, the host material currently being considered for the construction of a nuclear waste repository in Switzerland. Consolidated and drained triaxial tests on Opalinus Clay from the Mont Terri URL have been conducted in order to derive information on its strength and stiffness properties. Opalinus Clay specimens were tested both parallel to bedding (P-specimens) and perpendicular to bedding (S-specimens). The considered effective confining stress range (from 2 to 12 MPa) has been selected in order to reproduce possible in situ stress conditions for the repository. In this work, particular attention has been paid to the experimental procedure in order to ensure consolidated conditions and avoid generation of unwanted excess pore water pressure during drained shearing. The Skempton B parameter has been determined for all the tested specimens in order to ensure saturation. Both single-stage and multistage triaxial testing procedures were adopted in the experimental campaign. The results of the triaxial tests highlight an anisotropic elastic response of Opalinus Clay: S-specimens present a more compliant behaviour than P-specimens. The values of the Young modulus are found to increase with the increase in mean effective stress. The analysis of the peak and ultimate shear strength results reveals that the material behaves in a similar manner regardless of the considered direction of loading (P and S directions) with respect to the bedding orientation. Peak and ultimate failure envelopes for Opalinus Clay were derived for the investigated stress range.

  6. Current flow in a 3-terminal thin film contact with dissimilar materials and general geometric aspect ratios

    International Nuclear Information System (INIS)

    Zhang Peng; Hung, Derek M H; Lau, Y Y

    2013-01-01

    The current flow pattern, together with the contact resistance, is calculated analytically in a Cartesian 3-terminal thin film contact with dissimilar materials. The resistivities and the geometric dimensions in the individual contact members, as well as the terminal voltages, may assume arbitrary values. We show that the current flow patterns and the contact resistance may be conveniently decomposed into the even and odd solution. The even solution gives exclusively and totally the current flowing from the source to the gate. The odd solution gives exclusively and totally the current flowing from the source to the drain. Current crowding at the edges, and current partition in different regions are displayed. The analytic solutions are validated using a simulation code. The bounds on the variation of the contact resistance are given. This paper may be considered as the generalization of the transmission line model and the Kennedy-Murley model that were used extensively in the characterization of thin-film devices. For completeness, we include the general results for the cylindrical geometry, which are qualitatively similar to the even solution of the Cartesian geometry.

  7. Carbon storage change in a partially forestry-drained boreal mire determined through peat column inventories

    Energy Technology Data Exchange (ETDEWEB)

    Pitkanen, A.; Tahvanainen, T.; Simola, H. [Univ. of Eastern Finland, Joensuu (Finland). Dept. pf Biology; Turunen, J. [Geological Survey of Finland, Kuopio (Finland)

    2013-09-01

    To study the impact of forestry drainage on peat carbon storage, we cored paired quantitative peat samples from undrained and drained sides of an eccentric bog. Five pairs of 0 to {<=} 100-cm-deep surface-peat cores, and a pair of profiles representing the full peat deposit provided stratigraphic evidence of marked loss of surface peat due to drainage. For the drained side cores, we found a relative subsidence of 25-37 cm of the surface, and a loss of about 10 kg{sub DW}{sup m-2}, corresponding to 131 {+-} 28 g C m{sup -2} a{sup -1} (mean {+-} SE) for the post-drainage period. Similar peat loss was also found in the full deposit profiles, thus lending credibility to the whole-column inventory approach, even though the decrease (9 kg{sub DW} m{sup -2}) was relatively small in comparison with the total carbon storage (233 and 224 kg{sub DW} m{sup -2} for the undrained and drained sides, respectively). (orig.)

  8. 7 CFR 58.416 - Cheese vats, tanks and drain tables.

    Science.gov (United States)

    2010-01-01

    ... uniform heating. The inner liner shall be minimum 16 gauge stainless steel or other equally corrosion... jacket. The outer jacket shall be constructed of stainless steel or other metal which can be kept clean... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vats, tanks and drain tables. 58.416 Section 58...

  9. Optimal chest drain size: the rise of the small-bore pleural catheter.

    Science.gov (United States)

    Fysh, Edward T H; Smith, Nicola A; Lee, Y C Gary

    2010-12-01

    Drainage of the pleural space is not a modern concept, but the optimal size of chest drains to use remains debated. Conventional teaching advocates blunt dissection and large-bore tubes; but in recent years, small-bore catheters have gained popularity. In the absence of high-quality randomized data, this review summarizes the available literature on the choice of chest drains. The objective data supporting the use of large-bore tubes is scarce in most pleural diseases. Increasing evidence shows that small-bore catheters induce less pain and are of comparable efficacy to large-bore tubes, including in the management of pleural infection, malignant effusion, and pneumothoraces. The onus now is on those who favor large tubes to produce clinical data to justify the more invasive approach. © Thieme Medical Publishers.

  10. A comparative study of surgical drain placement and the use of kinesiologic tape to reduce postoperative morbidity after third molar surgery.

    Science.gov (United States)

    Genc, Aysenur; Cakarer, Sirmahan; Yalcin, Basak Keskin; Kilic, Beril Berivan; Isler, Sabri Cemil; Keskin, Cengizhan

    2018-04-19

    Our aim was to compare the effects of the surgical drain and kinesiotape applications on postoperative morbidity after mandibular third molar surgery in a split-mouth study design. A single-centre, split-mouth study was performed in 23 patients who needed surgical removal of bilateral mandibular third molars. Each patient was treated with a drain tube on one side of the mandible and Kinesio tape (KT) on the contralateral side. Swelling was significantly greater in the KT group than in the drain group throughout the study period. The groups did not differ significantly in the amount of trismus at any time point. The Visual Analogue Scale (VAS)-measured pain intensity was significantly lower in the drainage group. Patients with KT had greater postoperative discomfort than those with a drain tube. All patients were generally satisfied with their treatments. Although both treatments were useful, a surgical drain was significantly more effective at reducing swelling and pain intensity than Kinesio tape. The effects of both on trismus were similar.

  11. Use of a Nasal Speculum for Chest-Drain Insertion: A Simple Technique

    OpenAIRE

    Saxena, Pankaj; Konstantinov, Igor E.; Newman, Mark A.J.

    2006-01-01

    Tube thoracostomy is a very commonly performed procedure in cardiothoracic surgery. Insertion of a chest drain requires expertise to minimize complications. We describe a simple technique of using a nasal speculum to perform this procedure.

  12. A computational model for lower hybrid current drive

    International Nuclear Information System (INIS)

    Englade, R.C.; Bonoli, P.T.; Porkolab, M.

    1983-01-01

    A detailed simulation model for lower hybrid (LH) current drive in toroidal devices is discussed. This model accounts reasonably well for the magnitude of radio frequency (RF) current observed in the PLT and Alcator C devices. It also reproduces the experimental dependencies of RF current generation on toroidal magnetic field and has provided insights about mechanisms which may underlie the observed density limit of current drive. (author)

  13. Modelling of the ring current in Saturn's magnetosphere

    Directory of Open Access Journals (Sweden)

    G. Giampieri

    2004-01-01

    Full Text Available The existence of a ring current inside Saturn's magnetosphere was first suggested by Smith et al. (1980 and Ness et al. (1981, 1982, in order to explain various features in the magnetic field observations from the Pioneer 11 and Voyager 1 and 2 spacecraft. Connerney et al. (1983 formalized the equatorial current model, based on previous modelling work of Jupiter's current sheet and estimated its parameters from the two Voyager data sets. Here, we investigate the model further, by reconsidering the data from the two Voyager spacecraft, as well as including the Pioneer 11 flyby data set. First, we obtain, in closed form, an analytic expression for the magnetic field produced by the ring current. We then fit the model to the external field, that is the difference between the observed field and the internal magnetic field, considering all the available data. In general, through our global fit we obtain more accurate parameters, compared to previous models. We point out differences between the model's parameters for the three flybys, and also investigate possible deviations from the axial and planar symmetries assumed in the model. We conclude that an accurate modelling of the Saturnian disk current will require taking into account both of the temporal variations related to the condition of the magnetosphere, as well as non-axisymmetric contributions due to local time effects. Key words. Magnetospheric physics (current systems; planetary magnetospheres; plasma sheet

  14. Model experiment on change of seismic properties of a fracture caused by injecting/draining water; Chusui/haisui ni yoru kison kiretsu no dansei denpa tokusei no henka ni kansuru model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T; Koizumi, T; Sassa, K [Kyoto University, Kyoto (Japan). Faculty of Engineering

    1997-05-27

    Effect of water injection/draining on elastic waves penetrating through cracks is examined by measuring elastic waves before, during, and after the injection/draining of water into/from cracks in presence in granite. Two blocks of rock, with their crack-containing surfaces in contact with each other, are placed in a vessel, and water injection/draining is done through a hole on a vessel bottom side so that water will penetrate into the cracks. When the blocks are dry, there is almost no contact between the cracks, and so no crack penetrating waves are observed. Crack penetrating waves are produced when water is injected, and the position of the receiver sensing the penetrating waves changes as the water level rises. When the water level is lowered from the high water level, the waveform changes again as the level changes. The change in waveform is not so remarkable, however, as that observed during water injection thanks to the water residual in the cracks. It is now inferred that crack investigation is more effective when it is carried out with water being injected into dry cracks. The difference produced between the dry state and wet state when water is injected into dry cracks is used to detect the presence of cracks in this experiment, and this may be applied also to the investigation of cracks in the shallow part of the ground. 4 refs., 11 figs.

  15. Sensitivity Analysis of the Agricultural Policy/Environmental eXtender (APEX) for Phosphorus Loads in Tile-Drained Landscapes.

    Science.gov (United States)

    Ford, W; King, K; Williams, M; Williams, J; Fausey, N

    2015-07-01

    Numerical modeling is an economical and feasible approach for quantifying the effects of best management practices on dissolved reactive phosphorus (DRP) loadings from agricultural fields. However, tools that simulate both surface and subsurface DRP pathways are limited and have not been robustly evaluated in tile-drained landscapes. The objectives of this study were to test the ability of the Agricultural Policy/Environmental eXtender (APEX), a widely used field-scale model, to simulate surface and tile P loadings over management, hydrologic, biologic, tile, and soil gradients and to better understand the behavior of P delivery at the edge-of-field in tile-drained midwestern landscapes. To do this, a global, variance-based sensitivity analysis was performed, and model outputs were compared with measured P loads obtained from 14 surface and subsurface edge-of-field sites across central and northwestern Ohio. Results of the sensitivity analysis showed that response variables for DRP were highly sensitive to coupled interactions between presumed important parameters, suggesting nonlinearity of DRP delivery at the edge-of-field. Comparison of model results to edge-of-field data showcased the ability of APEX to simulate surface and subsurface runoff and the associated DRP loading at monthly to annual timescales; however, some high DRP concentrations and fluxes were not reflected in the model, suggesting the presence of preferential flow. Results from this study provide new insights into baseline tile DRP loadings that exceed thresholds for algal proliferation. Further, negative feedbacks between surface and subsurface DRP delivery suggest caution is needed when implementing DRP-based best management practices designed for a specific flow pathway. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  16. Design of a New Acceleration System for High-Current Pulsed Proton Beams from an ECR Source

    Science.gov (United States)

    Cooper, Andrew L.; Pogrebnyak, Ivan; Surbrook, Jason T.; Kelly, Keegan J.; Carlin, Bret P.; Champagne, Arthur E.; Clegg, Thomas B.

    2014-03-01

    A primary objective for accelerators at TUNL's Laboratory for Experimental Nuclear Astrophysics (LENA) is to maximize target beam intensity to ensure a high rate of nuclear events during each experiment. Average proton target currents of several mA are needed from LENA's electron cyclotron resonance (ECR) ion source because nuclear cross sections decrease substantially at energies of interest tube structures; and provide better heat dissipation by using deionized water to provide the current drain needed to establish the accelerating tube's voltage gradient. Details of beam optical modeling calculations, proposed accelerating tube design, and initial beam pulsing tests will be described. Work supported in part by USDOE Office of HE and Nuclear Physics.

  17. Application of Prefabricated Vertical Drain in Soil Improvement

    Directory of Open Access Journals (Sweden)

    Tedjakusuma B.

    2012-01-01

    Full Text Available Although the use of Prefabricated Vertical Drain (PVD in soil improvement is not new, this paper is interesting since it gives the full spectrum from preliminary design stage; trial embankment and pilot test to final soil improvement. The final installation of the PVD was based on the soil investigation report and the results of instrumentation monitoring. Finally, using back analysis, vertical and horizontal coefficients of consolidation and compression index can be determined, which can be applied to predict a more accurate prediction of settlement.

  18. Analysis of the AlGaN/GaN vertical bulk current on Si, sapphire, and free-standing GaN substrates

    International Nuclear Information System (INIS)

    Pérez-Tomás, A.; Fontserè, A.; Llobet, J.; Placidi, M.; Rennesson, S.; Chenot, S.; Moreno, J. C.; Cordier, Y.; Baron, N.

    2013-01-01

    The vertical bulk (drain-bulk) current (I db ) properties of analogous AlGaN/GaN hetero-structures molecular beam epitaxially grown on silicon, sapphire, and free-standing GaN (FS-GaN) have been evaluated in this paper. The experimental I db (25–300 °C) have been well reproduced with physical models based on a combination of Poole-Frenkel (trap assisted) and hopping (resistive) conduction mechanisms. The thermal activation energies (E a ), the (soft or destructive) vertical breakdown voltage (V B ), and the effect of inverting the drain-bulk polarity have also been comparatively investigated. GaN-on-FS-GaN appears to adhere to the resistive mechanism (E a = 0.35 eV at T = 25–300 °C; V B = 840 V), GaN-on-sapphire follows the trap assisted mechanism (E a = 2.5 eV at T > 265 °C; V B > 1100 V), and the GaN-on-Si is well reproduced with a combination of the two mechanisms (E a = 0.35 eV at T > 150 °C; V B = 420 V). Finally, the relationship between the vertical bulk current and the lateral AlGaN/GaN transistor leakage current is explored.

  19. Simulation model for electron irradiated IGZO thin film transistors

    Science.gov (United States)

    Dayananda, G. K.; Shantharama Rai, C.; Jayarama, A.; Kim, Hyun Jae

    2018-02-01

    An efficient drain current simulation model for the electron irradiation effect on the electrical parameters of amorphous In-Ga-Zn-O (IGZO) thin-film transistors is developed. The model is developed based on the specifications such as gate capacitance, channel length, channel width, flat band voltage etc. Electrical parameters of un-irradiated IGZO samples were simulated and compared with the experimental parameters and 1 kGy electron irradiated parameters. The effect of electron irradiation on the IGZO sample was analysed by developing a mathematical model.

  20. An elusive persistent left superior vena cava draining into left atrium

    NARCIS (Netherlands)

    A. Soward; F.J. ten Cate (Folkert); P.M. Fioretti (Paolo); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1986-01-01

    textabstractA case report of a persistent left superior vena cava draining into left atrium with a fibromuscular left ventricular outflow tract obstruction and a small atrial septal defect. The anomalous vessel escaped detection during two right and left heart catheterizations from the right arm and

  1. Oral tolerance is determined at the level of draining lymph nodes

    NARCIS (Netherlands)

    Wilsem, van E.G.; BrevÃ, J.; Savelkoul, H.; Claessen, A.; Scheper, R.J.; Kraal, G.

    1995-01-01

    In the skin and in the epithelium of the oral mucosa a comparable network of Langerhans cells can be found. Antigen application on either epithelium leads to rapid emigration of Langerhans cells to the draining lymph nodes. Application on the oral mucosa leads to tolerance induction while

  2. Human capital in European peripheral regions: brain - drain and brain - gain

    NARCIS (Netherlands)

    Coenen, Franciscus H.J.M.

    2004-01-01

    Project goal - The overall goal of the project is to build a legitimate transnational network to transfer ideas and experiences and implement measures to reduce brain drain and foster brain gain while reinforcing the economical and spatial development of peripheral regions in NWE. This means a

  3. Investigation on the electrical characteristics of a pentacene thin-film transistor and its reliability under positive drain bias stress

    International Nuclear Information System (INIS)

    Fan, Ching-Lin; Chiu, Ping-Cheng; Lin, Yu-Zuo; Yang, Tsung-Hsien; Chiang, Chin-Yuan

    2011-01-01

    This study systematically investigates the effects of pentacene deposition rates and channel lengths on the electrical characteristics of pentacene-based organic thin-film transistors (OTFTs), and the performance degradation of OTFTs under the positive drain bias stress. With a slower deposition rate of the pentacene channel layer, the larger grain size is formed, and it improves the performance of pentacene-based OTFTs. As the channel length decreases, the threshold voltage (V TH ) shifts toward the positive direction and the field-effect mobility (µ FE ) decreases, which are due to the drain-induced barrier lowering effect and the lower mobility in the active channel near the region of source/drain electrodes, respectively. In addition, we also propose a mechanism to present the channel length dependence on the field-effect mobility. Results also show that the pentacene-based OTFTs, which are under positive drain bias stress, exhibit greater performance degradation than those under negative drain bias stress. The greater performance degradation, the decreasing I ON and the larger V TH shift are due to the greater trap state density (N trap ) created in the bulk channel by the large lateral electrical field and the carriers injected into the gate insulator by the large vertical electrical field, respectively

  4. Influence of slow-release urea on nitrogen balance and portal-drained visceral nutrient flux in beef steers

    DEFF Research Database (Denmark)

    Taylor-Edwards, C C; Elam, N A; Kitts, S E

    2009-01-01

    Two experiments were conducted to evaluate the effects of slow-release urea (SRU) versus feed-grade urea on portal-drained visceral (PDV) nutrient flux, nutrient digestibility, and total N balance in beef steers.......Two experiments were conducted to evaluate the effects of slow-release urea (SRU) versus feed-grade urea on portal-drained visceral (PDV) nutrient flux, nutrient digestibility, and total N balance in beef steers....

  5. Global estimates of high-level brain drain and deficit.

    Science.gov (United States)

    Ioannidis, John P A

    2004-06-01

    Brain drain, the international migration of scientists in search of better opportunities, has been a long-standing concern, but quantitative measurements are uncommon and limited to specific countries or disciplines. We need to understand brain drain at a global level and estimate the extent to which scientists born in countries with low opportunities never realize their potential. Data on 1523 of the most highly cited scientists for 1981-1999 are analyzed. Overall, 31.9% of these scientists did not reside in the country where they were born (range 18.1-54.6% across 21 different scientific fields). There was great variability across developed countries in the proportions of foreign-born resident scientists and emigrating scientists. Countries without a critical mass of native scientists lost most scientists to migration. This loss occurred in both developed and developing countries. Adjusting for population and using the U.S. as reference, the number of highly cited native-born scientists was at least 75% of the expected number in only 8 countries other than the U.S. It is estimated that approximately 94% of the expected top scientists worldwide have not been able to materialize themselves due to various adverse conditions. Scientific deficit is only likely to help perpetuate these adverse conditions.

  6. Fine root production at drained peatland sites

    Energy Technology Data Exchange (ETDEWEB)

    Finer, L [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Laine, J [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1997-12-31

    The preliminary results of the Finnish project `Carbon balance of peatlands and climate change` show that fine roots play an important role in carbon cycling on peat soils. After drainage the roots of mire species are gradually replaced by the roots of trees and other forest species. Pine fine root biomass reaches a maximum level by the time of crown closure, some 20 years after drainage on pine mire. The aim of this study is to compare the results of the sequential coring method and the ingrowth bag method used for estimating fine root production on three drained peatland sites of different fertility. The results are preliminary and continuation to the work done in the study Pine root production on drained peatlands, which is part of the Finnish project `Carbon cycling on peatlands and climate change`. In this study the fine root biomass was greater on the poor site than on the rich sites. Pine fine root production increased with the decrease in fertility. Root turnover and the production of field layer species were greater on the rich sites than on the poor site. The results suggested that the in growth bag method measured more root activity than the magnitude of production. More than two growing seasons would have been needed to balance the root dynamics in the in growth bags with the surrounding soil. That time would probably have been longer on the poor site than on the rich ones and longer for pine and field layer consisting of dwarf shrubs than for field layer consisting of sedge like species and birch. (11 refs.)

  7. Fine root production at drained peatland sites

    Energy Technology Data Exchange (ETDEWEB)

    Finer, L. [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Laine, J. [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1996-12-31

    The preliminary results of the Finnish project `Carbon balance of peatlands and climate change` show that fine roots play an important role in carbon cycling on peat soils. After drainage the roots of mire species are gradually replaced by the roots of trees and other forest species. Pine fine root biomass reaches a maximum level by the time of crown closure, some 20 years after drainage on pine mire. The aim of this study is to compare the results of the sequential coring method and the ingrowth bag method used for estimating fine root production on three drained peatland sites of different fertility. The results are preliminary and continuation to the work done in the study Pine root production on drained peatlands, which is part of the Finnish project `Carbon cycling on peatlands and climate change`. In this study the fine root biomass was greater on the poor site than on the rich sites. Pine fine root production increased with the decrease in fertility. Root turnover and the production of field layer species were greater on the rich sites than on the poor site. The results suggested that the in growth bag method measured more root activity than the magnitude of production. More than two growing seasons would have been needed to balance the root dynamics in the in growth bags with the surrounding soil. That time would probably have been longer on the poor site than on the rich ones and longer for pine and field layer consisting of dwarf shrubs than for field layer consisting of sedge like species and birch. (11 refs.)

  8. A comparison of post-op haemoglobin levels and allogeneic blood transfusion rates following total knee arthroplasty without drainage or with reinfusion drains.

    Science.gov (United States)

    Hazarika, Shariff; Bhattacharya, Rajarshi; Bhavikatti, Mainudden; Dawson, Matthew

    2010-02-01

    The effects of re-infusion drains on the rate of allogeneic blood transfusion and post-op haemoglobin levels in Total Knee Arthroplasty were examined. A group of 22 patients undergoing primary Total Knee Arthroplasty using a CBCII Constavac Stryker re-infusion drainage system were compared with a group of 30 patients, matched for age, sex and type of prosthesis but without any drain usage. The re-infusion drain.group had a significantly lower day 1 and day 3 post-operative haemoglobin compared to the non-drainage group. The re-infusion drain group had a higher allogenic transfusion rate compared to the non-drainage group. There were no significant differences between the two groups regarding the rate of wound and transfusion related complications and mean length of post-operative stay. We found that reinfusion drains were ineffective in reducing allogeneic transfusion requirements as compared with non-drainage in total knee arthroplasty.

  9. Preservation of labile organic matter in soils of drained thaw lakes in Northern Alaska

    Science.gov (United States)

    Mueller, Carsten W.; Rethemeyer, Janet; Kao-Kniffin, Jenny; Löppmann, Sebastian; Hinkel, Kenneth; Bockheim, James

    2014-05-01

    A large number of studies predict changing organic matter (OM) dynamics in arctic soils due to global warming. In contrast to rather slowly altering bulk soil properties, single soil organic matter (SOM) fractions can provide a more detailed picture of the dynamics of differently preserved SOM pools in climate sensitive arctic regions. By the study of the chemical composition of such distinctive SOM fractions using nuclear magnetic resonance spectroscopy (NMR) together with radiocarbon analyses it is possible to evaluate the stability of the major OM pools. Approximately 50-75% of Alaska's Arctic Coastal Plain is covered with thaw lakes and drained thaw lakes that follow a 5,000 yr cycle of development (between creation and final drainage), thus forming a natural soil chronosequence. The drained thaw lakes offer the possibility to study SOM dynamics affected by permafrost processes over millennial timescales. In April 2010 we sampled 16 soil cores (including the active and permanent layer) reaching from young drained lakes (0-50 years since drainage) to ancient drained lakes (3000-5500 years since drainage). Air dried soil samples from soil horizons of the active and permanent layer were subjected to density fractionation in order to differentiate particulate OM and mineral associated OM. The chemical composition of the SOM fractions was analyzed by 13C CPMAS NMR spectroscopy. For a soil core of a young and an ancient drained thaw lake basin we also analyzed the 14C content. For the studied soils we can show that up to over 25 kg OC per square meter are stored mostly as labile, easily degradable organic matter rich in carbohydrates. In contrast only 10 kg OC per square meter were sequestered as presumably more stable mineral associated OC dominated by aliphatic compounds. Comparable to soils of temperate regions, we found small POM (dating we could show the stabilization of younger more labile OM at greater depth in buried O horizons. Additionally the study of the

  10. High performance Ω-gated Ge nanowire MOSFET with quasi-metallic source/drain contacts.

    Science.gov (United States)

    Burchhart, T; Zeiner, C; Hyun, Y J; Lugstein, A; Hochleitner, G; Bertagnolli, E

    2010-10-29

    Ge nanowires (NWs) about 2 µm long and 35 nm in diameter are grown heteroepitaxially on Si(111) substrates in a hot wall low-pressure chemical vapor deposition (LP-CVD) system using Au as a catalyst and GeH(4) as precursor. Individual NWs are contacted to Cu pads via e-beam lithography, thermal evaporation and lift-off techniques. Self-aligned and atomically sharp quasi-metallic copper-germanide source/drain contacts are achieved by a thermal activated phase formation process. The Cu(3)Ge segments emerge from the Cu contact pads through axial diffusion of Cu which was controlled in situ by SEM, thus the active channel length of the MOSFET is adjusted without any restrictions from a lithographic process. Finally the conductivity of the channel is enhanced by Ga(+) implantation leading to a high performance Ω-gated Ge-NW MOSFET with saturation currents of a few microamperes.

  11. Final Report: Baseline Selenium Monitoring of Agricultural Drains Operated by the Imperial Irrigation District in the Salton Sea Basin, California

    Science.gov (United States)

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2010-01-01

    This report summarizes comprehensive findings from a 4-year-long field investigation to document baseline environmental conditions in 29 agricultural drains and ponds operated by the Imperial Irrigation District along the southern border of the Salton Sea. Routine water-quality collections and fish community assessments were conducted on as many as 16 sampling dates at roughly quarterly intervals from July 2005 to April 2009. The water-quality measurements included total suspended solids and total (particulate plus dissolved) selenium. With one exception, fish were surveyed with baited minnow traps at quarterly intervals during the same time period. However, in July 2007, fish surveys were not conducted because we lacked permission from the California Department of Fish and Game for incidental take of desert pupfish (Cyprinodon macularius), an endangered species. During April and October 2006-08, water samples also were collected from seven intensively monitored drains (which were selected from the 29 total drains) for measurement of particulate and dissolved selenium, including inorganic and organic fractions. In addition, sediment, aquatic food chain matrices [particulate organic detritus, filamentous algae, net plankton, and midge (chironomid) larvae], and two fish species (western mosquitofish, Gambusia affinis; and sailfin molly, Poecilia latipinna) were sampled from the seven drains for measurement of total selenium concentrations. The mosquitofish and mollies were intended to serve as surrogates for pupfish, which we were not permitted to sacrifice for selenium determinations. Water quality (temperature, dissolved oxygen, pH, specific conductance, and turbidity) values were typical of surface waters in a hot, arid climate. A few drains exhibited brackish, near-anoxic conditions, especially during summer and fall when water temperatures occasionally exceeded 30 degrees Celsius. Total selenium concentrations in water were directly correlated with salinity and

  12. Study on the drain bias effect on negative bias temperature instability degradation of an ultra-short p-channel metal-oxide-semiconductor field-effect transistor

    International Nuclear Information System (INIS)

    Yan-Rong, Cao; Xiao-Hua, Ma; Yue, Hao; Shi-Gang, Hu

    2010-01-01

    This paper studies the effect of drain bias on ultra-short p-channel metal-oxide-semiconductor field-effect transistor (PMOSFET) degradation during negative bias temperature (NBT) stress. When a relatively large gate voltage is applied, the degradation magnitude is much more than the drain voltage which is the same as the gate voltage supplied, and the time exponent gets larger than that of the NBT instability (NBTI). With decreasing drain voltage, the degradation magnitude and the time exponent all get smaller. At some values of the drain voltage, the degradation magnitude is even smaller than that of NBTI, and when the drain voltage gets small enough, the exhibition of degradation becomes very similar to the NBTI degradation. When a relatively large drain voltage is applied, with decreasing gate voltage, the degradation magnitude gets smaller. However, the time exponent becomes larger. With the help of electric field simulation, this paper concludes that the degradation magnitude is determined by the vertical electric field of the oxide, the amount of hot holes generated by the strong channel lateral electric field at the gate/drain overlap region, and the time exponent is mainly controlled by localized damage caused by the lateral electric field of the oxide in the gate/drain overlap region where hot carriers are produced. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  13. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    Science.gov (United States)

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  14. Current-voltage model of LED light sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2012-01-01

    Amplitude modulation is rarely used for dimming light-emitting diodes in polychromatic luminaires due to big color shifts caused by varying magnitude of LED driving current and nonlinear relationship between intensity of a diode and driving current. Current-voltage empirical model of light...

  15. General Potential-Current Model and Validation for Electrocoagulation

    International Nuclear Information System (INIS)

    Dubrawski, Kristian L.; Du, Codey; Mohseni, Madjid

    2014-01-01

    A model relating potential and current in continuous parallel plate iron electrocoagulation (EC) was developed for application in drinking water treatment. The general model can be applied to any EC parallel plate system relying only on geometric and tabulated input variables without the need of system-specific experimentally derived constants. For the theoretical model, the anode and cathode were vertically divided into n equipotential segments in a single pass, upflow, and adiabatic EC reactor. Potential and energy balances were simultaneously solved at each vertical segment, which included the contribution of ionic concentrations, solution temperature and conductivity, cathodic hydrogen flux, and gas/liquid ratio. We experimentally validated the numerical model with a vertical upflow EC reactor using a 24 cm height 99.99% pure iron anode divided into twelve 2 cm segments. Individual experimental currents from each segment were summed to determine total current, and compared with the theoretically derived value. Several key variables were studied to determine their impact on model accuracy: solute type, solute concentration, current density, flow rate, inter-electrode gap, and electrode surface condition. Model results were in good agreement with experimental values at cell potentials of 2-20 V (corresponding to a current density range of approximately 50-800 A/m 2 ), with mean relative deviation of 9% for low flow rate, narrow electrode gap, polished electrodes, and 150 mg/L NaCl. Highest deviation occurred with a large electrode gap, unpolished electrodes, and Na 2 SO 4 electrolyte, due to parasitic H 2 O oxidation and less than unity current efficiency. This is the first general model which can be applied to any parallel plate EC system for accurate electrochemical voltage or current prediction

  16. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    OpenAIRE

    Xiao Guo; Kang-He Xie; Yue-Bao Deng

    2014-01-01

    This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1) the flow with the threshold gradie...

  17. Disinfection of drain water of tomato by means of UV radiation and slow sand filtration in real greenhouse circumstances.

    Science.gov (United States)

    De Rocker, E; Goen, K; Van Poucke, K

    2006-01-01

    The efficiency of the disinfection of drain water was tested at 11 greenhouses with tomato cultivation on rockwool substrate in Flanders (Belgium) by means of mycological analysis. In addition the presence of phytopathogenic fungi in the drain water was analysed at 2 supplementary greenhouses with recirculation without disinfection.

  18. Low Noise Bias Current/Voltage References Based on Floating-Gate MOS Transistors

    DEFF Research Database (Denmark)

    Igor, Mucha

    1997-01-01

    The exploitation of floating-gate MOS transistors as reference current and voltage sources is investigated. Test structures of common source and common drain floating-gate devices have been implemented in a commercially available 0.8 micron double-poly CMOS process. The measurements performed...

  19. Dynamic Looping of a Free-Draining Polymer

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Felix X. -F.; Stinis, Panos; Qian, Hong

    2018-01-11

    Here, we revisit the celebrated Wilemski--Fixman (WF) treatment for the looping time of a free-draining polymer. The WF theory introduces a sink term into the Fokker--Planck equation for the $3(N+1)$-dimensional Ornstein--Uhlenbeck process of polymer dynamics, which accounts for the appropriate boundary condition due to the formation of a loop. The assumption for WF theory is considerably relaxed. A perturbation method approach is developed that justifies and generalizes the previous results using either a delta sink or a Heaviside sink. For both types of sinks, we show that under the condition of a small dimensionless $\\epsilon$, the ratio of capture radius to the Kuhn length, we are able to systematically produce all known analytical and asymptotic results obtained by other methods. This includes most notably the transition regime between the $N^2$ scaling of Doi, and $N\\sqrt{N}/\\epsilon$ scaling of Szabo, Schulten, and Schulten. The mathematical issue at play is the nonuniform convergence of $\\epsilon\\to 0$ and $N\\to\\infty$, the latter being an inherent part of the theory of a Gaussian polymer. Our analysis yields a novel term in the analytical expression for the looping time with small $\\epsilon$, which was previously unknown. Monte Carlo numerical simulations corroborate the analytical findings. The systematic method developed here can be applied to other systems modeled by multidimensional Smoluchowski equations.

  20. Giant Dirac point shift of graphene phototransistors by doped silicon substrate current

    Directory of Open Access Journals (Sweden)

    Masaaki Shimatani

    2016-03-01

    Full Text Available Graphene is a promising new material for photodetectors due to its excellent optical properties and high-speed response. However, graphene-based phototransistors have low responsivity due to the weak light absorption of graphene. We have observed a giant Dirac point shift upon white light illumination in graphene-based phototransistors with n-doped Si substrates, but not those with p-doped substrates. The source-drain current and substrate current were investigated with and without illumination for both p-type and n-type Si substrates. The decay time of the drain-source current indicates that the Si substrate, SiO2 layer, and metal electrode comprise a metal-oxide-semiconductor (MOS capacitor due to the presence of defects at the interface between the Si substrate and SiO2 layer. The difference in the diffusion time of the intrinsic major carriers (electrons and the photogenerated electron-hole pairs to the depletion layer delays the application of the gate voltage to the graphene channel. Therefore, the giant Dirac point shift is attributed to the n-type Si substrate current. This phenomenon can be exploited to realize high-performance graphene-based phototransistors.

  1. Giant Dirac point shift of graphene phototransistors by doped silicon substrate current

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Masaaki; Ogawa, Shinpei, E-mail: Ogawa.Shimpei@eb.MitsubishiElectric.co.jp; Fujisawa, Daisuke [Advanced Technology R& D Center, Mitsubishi Electric Corporation, 8-1-1 Tsukaguchi-Honmachi, Amagasaki, Hyogo 661-8661 (Japan); Okuda, Satoshi [Advanced Technology R& D Center, Mitsubishi Electric Corporation, 8-1-1 Tsukaguchi-Honmachi, Amagasaki, Hyogo 661-8661 (Japan); The Institute of the Scientific and Industrial Research, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Kanai, Yasushi; Ono, Takao; Matsumoto, Kazuhiko [The Institute of the Scientific and Industrial Research, Osaka University, Ibaraki, Osaka 567-0047 (Japan)

    2016-03-15

    Graphene is a promising new material for photodetectors due to its excellent optical properties and high-speed response. However, graphene-based phototransistors have low responsivity due to the weak light absorption of graphene. We have observed a giant Dirac point shift upon white light illumination in graphene-based phototransistors with n-doped Si substrates, but not those with p-doped substrates. The source-drain current and substrate current were investigated with and without illumination for both p-type and n-type Si substrates. The decay time of the drain-source current indicates that the Si substrate, SiO{sub 2} layer, and metal electrode comprise a metal-oxide-semiconductor (MOS) capacitor due to the presence of defects at the interface between the Si substrate and SiO{sub 2} layer. The difference in the diffusion time of the intrinsic major carriers (electrons) and the photogenerated electron-hole pairs to the depletion layer delays the application of the gate voltage to the graphene channel. Therefore, the giant Dirac point shift is attributed to the n-type Si substrate current. This phenomenon can be exploited to realize high-performance graphene-based phototransistors.

  2. Analytic modeling of axisymmetric disruption halo currents

    International Nuclear Information System (INIS)

    Humphreys, D.A.; Kellman, A.G.

    1999-01-01

    Currents which can flow in plasma facing components during disruptions pose a challenge to the design of next generation tokamaks. Induced toroidal eddy currents and both induced and conducted poloidal ''halo'' currents can produce design-limiting electromagnetic loads. While induction of toroidal and poloidal currents in passive structures is a well-understood phenomenon, the driving terms and scalings for poloidal currents flowing on open field lines during disruptions are less well established. A model of halo current evolution is presented in which the current is induced in the halo by decay of the plasma current and change in enclosed toroidal flux while being convected into the halo from the core by plasma motion. Fundamental physical processes and scalings are described in a simplified analytic version of the model. The peak axisymmetric halo current is found to depend on halo and core plasma characteristics during the current quench, including machine and plasma dimensions, resistivities, safety factor, and vertical stability growth rate. Two extreme regimes in poloidal halo current amplitude are identified depending on the minimum halo safety factor reached during the disruption. A 'type I' disruption is characterized by a minimum safety factor that remains relatively high (typically 2 - 3, comparable to the predisruption safety factor), and a relatively low poloidal halo current. A 'type II' disruption is characterized by a minimum safety factor comparable to unity and a relatively high poloidal halo current. Model predictions for these two regimes are found to agree well with halo current measurements from vertical displacement event disruptions in DIII-D [T. S. Taylor, K. H. Burrell, D. R. Baker, G. L. Jackson, R. J. La Haye, M. A. Mahdavi, R. Prater, T. C. Simonen, and A. D. Turnbull, open-quotes Results from the DIII-D Scientific Research Program,close quotes in Proceedings of the 17th IAEA Fusion Energy Conference, Yokohama, 1998, to be published in

  3. Acellular Dermal Matrix in Reconstructive Breast Surgery: Survey of Current Practice among Plastic Surgeons

    Directory of Open Access Journals (Sweden)

    Ahmed M. S. Ibrahim, MD

    2015-04-01

    Conclusions: Plastic surgeons currently use ADM in breast reconstruction for both immediate and staged procedures. Of those responding, a majority of plastic surgeons will incorporate drains and use postoperative antibiotics for more than 48 hours.

  4. Extended behavioural modelling of FET and lattice-mismatched HEMT devices

    Science.gov (United States)

    Khawam, Yahya; Albasha, Lutfi

    2017-07-01

    This study presents an improved large signal model that can be used for high electron mobility transistors (HEMTs) and field effect transistors using measurement-based behavioural modelling techniques. The steps for accurate large and small signal modelling for transistor are also discussed. The proposed DC model is based on the Fager model since it compensates between the number of model's parameters and accuracy. The objective is to increase the accuracy of the drain-source current model with respect to any change in gate or drain voltages. Also, the objective is to extend the improved DC model to account for soft breakdown and kink effect found in some variants of HEMT devices. A hybrid Newton's-Genetic algorithm is used in order to determine the unknown parameters in the developed model. In addition to accurate modelling of a transistor's DC characteristics, the complete large signal model is modelled using multi-bias s-parameter measurements. The way that the complete model is performed is by using a hybrid multi-objective optimisation technique (Non-dominated Sorting Genetic Algorithm II) and local minimum search (multivariable Newton's method) for parasitic elements extraction. Finally, the results of DC modelling and multi-bias s-parameters modelling are presented, and three-device modelling recommendations are discussed.

  5. Land Use Impacts on Water Quality of Rivers draining from Mulanje ...

    African Journals Online (AJOL)

    Land Use Impacts on Water Quality of Rivers draining from Mulanje Mountain: A Case of Ruo River in the Southern Malawi. ... The research recommends an integrated water resources management approach where all users and relevant stakeholders should take an active role in the conservation of Ruo River catchment in ...

  6. Structure of a steady drain-hole vortex in a viscous fluid

    DEFF Research Database (Denmark)

    Bøhling, Lasse; Andersen, Anders Peter; Fabre, D.

    2010-01-01

    We use direct numerical simulations to study a steady bathtub vortex in a cylindrical tank with a central drain-hole, a fiat stress-free surface and velocity prescribed at the inlet. We find that the qualitative structure of the meridional flow does not depend on the radial Reynolds number, where...

  7. Microscopic models for bridging electrostatics and currents

    Science.gov (United States)

    Borghi, L.; DeAmbrosis, A.; Mascheretti, P.

    2007-03-01

    A teaching sequence based on the use of microscopic models to link electrostatic phenomena with direct currents is presented. The sequence, devised for high school students, was designed after initial work carried out with student teachers attending a school of specialization for teaching physics at high school, at the University of Pavia. The results obtained with them are briefly presented, because they directed our steps for the development of the teaching sequence. For both the design of the experiments and their interpretation, we drew inspiration from the original works of Alessandro Volta; in addition, a structural model based on the particular role of electrons as elementary charges both in electrostatic phenomena and in currents was proposed. The teaching sequence starts from experiments on charging objects by rubbing and by induction, and engages students in constructing microscopic models to interpret their observations. By using these models and by closely examining the ideas of tension and capacitance, the students acknowledge that a charging (or discharging) process is due to the motion of electrons that, albeit for short time intervals, represent a current. Finally, they are made to see that the same happens in transients of direct current circuits.

  8. Mechanism and modelling of source/drain asymmetry variation in 65 nm CMOS devices for SRAM and logic applications

    International Nuclear Information System (INIS)

    Lee, T H; Fang, Y K; Chiang, Y T; Lin, C T; Chen, M S; Cheng, O

    2008-01-01

    The source/drain asymmetry variation of 65 nm CMOS devices for SRAM and logic applications has been investigated in detail. For the first time, we observe that the asymmetry variation is proportional to the inverse of the root square of the device area. In other words, the asymmetry variation should become worse for future advanced CMOS technologies. Fortunately, through the T-CAD simulations and experiments, we find the variation can be improved significantly with the optimization of the poly-gate grain size, extra laser annealing and using a vertical profile poly-gate. Furthermore, the improvement in asymmetry variation leads to a better static noise margin of SRAM

  9. Numerical modeling of transformer inrush currents

    Energy Technology Data Exchange (ETDEWEB)

    Cardelli, E. [Department of Industrial Engineering, University of Perugia, I-06125 Perugia (Italy); Center for Electric and Magnetic Applied Research (Italy); Faba, A., E-mail: faba@unipg.it [Department of Industrial Engineering, University of Perugia, I-06125 Perugia (Italy); Center for Electric and Magnetic Applied Research (Italy)

    2014-02-15

    This paper presents an application of a vector hysteresis model to the prediction of the inrush current due the arbitrary initial excitation of a transformer after a fault. The approach proposed seems promising in order to predict the transient overshoot in current and the optimal time to close the circuit after the fault.

  10. Study of drain-extended NMOS under electrostatic discharge stress in 28 nm and 40 nm CMOS process

    Science.gov (United States)

    Wang, Weihuai; Jin, Hao; Dong, Shurong; Zhong, Lei; Han, Yan

    2016-02-01

    Researches on the electrostatic discharge (ESD) performance of drain-extended NMOS (DeNMOS) under the state-of-the-art 28 nm and 40 nm bulk CMOS process are performed in this paper. Three distinguishing phases of avalanche breakdown stage, depletion region push-out stage and parasitic NPN turn on stage of the gate-grounded DeNMOS (GG-DeNMOS) fabricated under 28 nm CMOS process measured with transmission line pulsing (TLP) test are analyzed through TCAD simulations and tape-out silicon verification detailedly. Damage mechanisms and failure spots of GG-DeNMOS under both CMOS processes are thermal breakdown of drain junction. Improvements based on the basic structure adjustments can increase the GG-DeNMOS robustness from original 2.87 mA/μm to the highest 5.41 mA/μm. Under 40 nm process, parameter adjustments based on the basic structure have no significant benefits on the robustness improvements. By inserting P+ segments in the N+ implantation of drain or an entire P+ strip between the N+ implantation of drain and polysilicon gate to form the typical DeMOS-SCR (silicon-controlled rectifier) structure, the ESD robustness can be enhanced from 1.83 mA/μm to 8.79 mA/μm and 29.78 mA/μm, respectively.

  11. Model for the resistive critical current transition in composite superconductors

    International Nuclear Information System (INIS)

    Warnes, W.H.

    1988-01-01

    Much of the research investigating technological type-II superconducting composites relies on the measurement of the resistive critical current transition. We have developed a model for the resistive transition which improves on older models by allowing for the very different nature of monofilamentary and multifilamentary composite structures. The monofilamentary model allows for axial current flow around critical current weak links in the superconducting filament. The multifilamentary model incorporates an additional radial current transfer between neighboring filaments. The development of both models is presented. It is shown that the models are useful for extracting more information from the experimental data than was formerly possible. Specific information obtainable from the experimental voltage-current characteristic includes the distribution of critical currents in the composite, the average critical current of the distribution, the range of critical currents in the composite, the field and temperature dependence of the distribution, and the fraction of the composite dissipating energy in flux flow at any current. This additional information about the distribution of critical currents may be helpful in leading toward a better understanding of flux pinning in technological superconductors. Comparison of the models with several experiments is given and shown to be in reasonable agreement. Implications of the models for the measurement of critical currents in technological composites is presented and discussed with reference to basic flux pinning studies in such composites

  12. Influence of a drain field plate on the forward blocking characteristics of an AlGaN/GaN high electron mobility transistor

    International Nuclear Information System (INIS)

    Zhao Sheng-Lei; Yue Tong; Wang Yi; Luo Jun; Mao Wei; Ma Xiao-Hua; Hao Yue; Chen Wei-Wei

    2013-01-01

    In this paper, the influence of a drain field plate (FP) on the forward blocking characteristics of an AlGaN/GaN high electron mobility transistor (HEMT) is investigated. The HEMT with only a gate FP is optimized, and breakdown voltage V BR is saturated at 1085 V for gate—drain spacing L GD ≥ 8 μm. On the basis of the HEMT with a gate FP, a drain FP is added with L GD = 10 μm. For the length of the drain FP L DF ≤ 2 μm, V BR is almost kept at 1085 V, showing no degradation. When L DF exceeds 2 μm, V BR decreases obviously as L DF increases. Moreover, the larger the L DF , the larger the decrease of V BR . It is concluded that the distance between the gate edge and the drain FP edge should be larger than a certain value to prevent the drain FP from affecting the forward blocking voltage and the value should be equal to the L GD at which V BR begins to saturate in the first structure. The electric field and potential distribution are simulated and analyzed to account for the decrease of V BR

  13. Experimental modeling of eddy current inspection capabilities

    International Nuclear Information System (INIS)

    Junker, W.R.; Clark, W.G.

    1984-01-01

    This chapter examines the experimental modeling of eddy current inspection capabilities based upon the use of liquid mercury samples designed to represent metal components containing discontinuities. A brief summary of past work with mercury modeling and a detailed discussion of recent experiments designed to further evaluate the technique are presented. The main disadvantages of the mercury modeling concept are that mercury is toxic and must be handled carefully, liquid mercury can only be used to represent nonferromagnetic materials, and wetting and meniscus problems can distort the effective size of artificial discontinuities. Artificial discontinuities placed in a liquid mercury sample can be used to represent discontinuities in solid metallic structures. Discontinuity size and type cannot be characterized from phase angle and signal amplitude data developed with a surface scanning, pancake-type eddy current probe. It is concluded that the mercury model approach can greatly enhance the overall understanding and applicability of eddy current inspection techniques

  14. Quality Education Improvement: Yemen and the Problem of the "Brain Drain"

    Science.gov (United States)

    Muthanna, Abdulghani

    2015-01-01

    This paper presents an overview of the problems that hinder improvement of the quality of education in Yemen, with a particular focus on higher education institutions. It discusses in particular the problem of the brain drain and why this phenomenon is occurring in Yemen. Semi-structured interviews with three professors at higher education…

  15. Greenhouse gas balances in low-productive drained boreal peatlands - is climate-friendly management possible?

    Science.gov (United States)

    Ojanen, Paavo; Minkkinen, Kari; Heikkinen, Tiina; Penttilä, Timo

    2016-04-01

    Five million hectares of peatland has been drained for forestry in Finland. About 20% of that, i.e. one million hectares, has been estimated to be so low-productive that the profitability of keeping them in forestry is questionable. At the same time, drainage has introduced changes in the ecosystem functions of these peatlands, including fluxes of greenhouse gases. Options to manage such peatlands include for example 1) no measures, i.e. leaving the drained peatlands as they are 2) increasing intensity by e.g. repetitive fertilisations and 3) restoration back to functional peatlands. Here we estimate the greenhouse gas impacts of these three management options. We collected GHG and organic carbon flux data from 50 low-productive peatlands under these management options over two years 2014-2015. Gas fluxes (CO2, CH4, N2O) were measured with closed chambers. Litter production rates of different plants above and below ground were estimated using litter traps (trees), biomass sampling (roots), through-grow nets (mosses), allometric biomass models (other vasculars) and published turnover rates (roots, other vasculars). Characteristics for estimating tree stand biomass increment were measured at each site from circular sample plots. In this presentation we will estimate the GHG impacts for the different management options, and aim to find the most climate-friendly options for the management of low-productive peatlands in the short and long term. This work was funded by Life+ LIFE12/ENV/FI/150.

  16. Movement of gasified oil in an infinite stratum drained by a single well

    Energy Technology Data Exchange (ETDEWEB)

    Tomel' gas, V A

    1965-01-01

    This article presents a method of calculating the flow of gas and oil into a well, which drains a reservoir by the solution drive mechanism. The following conditions are assumed: (1) Initially, an infinite homogeneous reservoir is saturated with oil above the bubble point; (2) the well draining the reservoir is operated at constant pressure, below the bubble point; and (3) the reservoir contains 2 zones; the zone fartherest from the well contains only oil at a pressure above the bubble point, while the zone nearest the well contains both oil and gas. The pressure and oil saturation gradients around the well are calculated for a variety of conditions, and the results are shown graphically. As pressure drawdown increases, oil production increases and the gas factor at first decreases and then increases rapidly.

  17. X-ray K-edge analysis of drain lines in Wilhelm Hall, Ames Laboratory

    International Nuclear Information System (INIS)

    Jensen, T.; Whitmore, C.; Iowa State Univ., Ames, IA

    1999-01-01

    From August 12--27, 1998 X-ray K-edge measurements were made on drain lines in seven rooms in Wilhelm Hall, Ames Laboratory. The purpose of these measurements was to determine the extent of thorium (and other heavy metal) contamination inside these pipes. The K-edge method is a noninvasive inspection technique that can provide accurate quantification of heavy metal contamination interior to an object. Of the seven drain lines inspected, one was found to have no significant contamination, three showed significant thorium deposits, two showed mercury contamination, and one line was found to contain mercury, thorium and uranium. The K-edge measurements were found to be consistent with readings from hand-held survey meters, and provided much greater detail on the location and amount of heavy metal contamination

  18. Year 3 Summary Report: Baseline Selenium Monitoring of Agricultural Drains Operated by the Imperial Irrigation District in the Salton Sea Basin

    Science.gov (United States)

    Saiki, Michael K.; Martin, Barbara A.; May, Thomas W.

    2008-01-01

    This report summarizes findings from the third year of a 4-year-long field investigation to document selected baseline environmental conditions in 29 agricultural drains and ponds operated by the Imperial Irrigation District along the southern border of the Salton Sea. Routine water quality and fish species were measured at roughly quarterly intervals from April 2007 to January 2008. The water quality measurements included total suspended solids and total (particulate plus dissolved) selenium. In addition, during April and October 2007, water samples were collected from seven intensively monitored drains for measurement of particulate and dissolved selenium, including inorganic and organic fractions. In addition, sediment, aquatic food chain matrices (particulate organic detritus, filamentous algae, net plankton, and midge [chironomid] larvae), and two fish species (western mosquitofish, Gambusia affinis; and sailfin molly, Poecilia latipinna) were sampled from the seven drains for measurement of total selenium concentrations. The mosquitofish and mollies were intended to serve as surrogates for desert pupfish (Cyprinodon macularius), an endangered species that we were not permitted to take for selenium determinations. Water quality values were typical of surface waters in a hot desert climate. A few drains exhibited brackish, near anoxic conditions especially during the summer and fall when water temperatures occasionally exceeded 30 degrees C. In general, total selenium concentrations in water varied directly with conductivity and inversely with pH. Although desert pupfish were found in several drains, sometimes in relatively high numbers, the fish faunas of most drains and ponds were dominated by nonnative species, especially red shiner (Cyprinella lutrensis), mosquitofish, and mollies. Dissolved selenium in water samples from the seven intensively monitored drains ranged from 0.700 to 24.1 ug/L, with selenate as the major constituent in all samples. Selenium

  19. Current Enhancement with Contact-Area-Limited Doping for Bottom-Gate, Bottom-Contact Organic Thin-Film Transistors

    Science.gov (United States)

    Noda, Kei; Wakatsuki, Yusuke; Yamagishi, Yuji; Wada, Yasuo; Toyabe, Toru; Matsushige, Kazumi

    2013-02-01

    The current enhancement mechanism in contact-area-limited doping for bottom-gate, bottom-contact (BGBC) p-channel organic thin-film transistors (OTFTs) was investigated both by simulation and experiment. Simulation results suggest that carrier shortage and large potential drop occur in the source-electrode/channel interface region in a conventional BGBC OTFT during operation, which results in a decrease in the effective field-effect mobility. These phenomena are attributed to the low carrier concentration of active semiconductor layers in OTFTs and can be alleviated by contact-area-limited doping, where highly doped layers are prepared over source-drain electrodes. According to two-dimensional current distribution obtained from the device simulation, a current flow from the source electrode to the channel region via highly doped layers is generated in addition to the direct carrier injection from the source electrode to the channel, leading to the enhancement of the drain current and effective field-effect mobility. The expected current enhancement mechanism in contact-area-limited doping was experimentally confirmed in typical α-sexithiophene (α-6T) BGBC thin-film transistors.

  20. Hydrobiogeochemical interactions in 'anoxic' limestone drains for neutralization of acidic mine drainage

    Science.gov (United States)

    Robbins, E.I.; Cravotta, C.A.; Savela, C.E.; Nord, G.L.

    1999-01-01

    Processes affecting neutralization of acidic coal mine drainage were evaluated within 'anoxic' limestone drains (ALDs). Influents had pH???3.5 and dissolved oxygen treatment step is indicated to promote Al removal before diverting acidic mine water into alkalinity-producing materials. ?? 1998 Elsevier Science Ltd.