  1. Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry

    International Nuclear Information System (INIS)

    Molina P, D.; Pernas S, R.; Martinez G, A.

    2006-01-01

    The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

  2. Type tests to the automatic system of thermoluminescent dosimetry acquired by the CPHR for personnel dosimetry

    International Nuclear Information System (INIS)

    Molina P, D.; Pernas S, R.

    2005-01-01

    The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF: Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

  3. Neutron spectrum adjustment using reaction rate data acquired with a liquid dosimetry system

    International Nuclear Information System (INIS)

    Smith, D.L.; Ikeda, Y.; Uno, Y.; Maekawa, F.

    1997-01-01

    A dosimetry technique based on neutron activation of circulating water with dissolved salts is discussed. The neutron source was the FNS accelerator at JAERI, Tokai, Japan. Yttrium chloride hexahydrate (YCl 3· 6H 2 O) was the salt (264.9 grams dissolved in 16.094 liters of water). Gamma-ray yields were measured with an intrinsic Ge detector. The following reactions were examined: (1) 16 O(n,p) 16 N (E thresh = 10.245 MeV, t 1/2 = 7.13 sec, E γ = 6.129 MeV); (2) 37 Cl(n,p) 37 S (E thresh = 4.194 MeV, t 1/2 = 5.05 min, E γ = 3.104 MeV); (3) 89 Y(n,n') 89m Y (E thresh = 0.919 MeV, t 1/2 = 16.06 sec, E γ = 0.909 MeV). This paper describes use of the generalized least-squares (GLS) method to adjust the neutron spectrum

  4. Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Clift, Corey; Thomas, Andrew; Chang Zheng; Oldham, Mark [Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710 (United States); Adamovics, John [Department of Chemistry, Rider University, Lawrenceville, NJ 08648 (United States); Das, Indra [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN 46202 (United States)], E-mail: cclift@montefiore.org

    2010-03-07

    Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (S{sub c,p}), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT film was used for independent verification. Measurements of S{sub c,p} made with PRESAGE and film agreed with mini-ion chamber commissioning data to within 4% for every field (range 0.2-3.6% for PRESAGE, and 1.6-3.6% for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE/optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE. The advantages of the PRESAGE (registered) system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.

  5. Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system

    International Nuclear Information System (INIS)

    Clift, Corey; Thomas, Andrew; Chang Zheng; Oldham, Mark; Adamovics, John; Das, Indra

    2010-01-01

    Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (S c,p ), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT film was used for independent verification. Measurements of S c,p made with PRESAGE and film agreed with mini-ion chamber commissioning data to within 4% for every field (range 0.2-3.6% for PRESAGE, and 1.6-3.6% for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE/optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE. The advantages of the PRESAGE (registered) system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.

  6. Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE®/ optical-CT 3D dosimetry system

    Science.gov (United States)

    Clift, Corey; Thomas, Andrew; Adamovics, John; Chang, Zheng; Das, Indra; Oldham, Mark

    2010-03-01

    Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE® read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (Sc, p), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT® film was used for independent verification. Measurements of Sc, p made with PRESAGE® and film agreed with mini-ion chamber commissioning data to within 4% for every field (range 0.2-3.6% for PRESAGE®, and 1.6-3.6% for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE®/optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE®. The advantages of the PRESAGE® system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.

  7. Dosimetry system 1986

    International Nuclear Information System (INIS)

    Woolson, William A.; Egbert, Stephen D.; Gritzner, Michael L.

    1987-01-01

    In May 1983, the authors proposed a dosimetry system for use by the Radiation Effects Research Foundation (RERF) that would incorporate the new findings and calculations of the joint United States - Japan working groups on the reassessment of A-bomb dosimetry. The proposed dosimetry system evolved from extensive discussions with RERF personnel, numerous meetings of the scientists from Japan and the United States involved in the dosimetry reassessment research, and requirements expressed by epidemiologists and radiobiologists on the various review panels. The dosimetry system proposed was based on considerations of the dosimetry requirements for the normal work of RERF and for future research in radiobiology, the computerized input data on A-bomb survivors available in the RERF data base, the level of detail, precision, and accuracy of various components of the dosimetric estimates, and the computer resources available at RERF in Hiroshima. These discussions and our own experience indicated that, in light of the expansion of computer and radiation technologies and the desire for more detail in the dosimetry, an entirely new approach to the dosimetry system was appropriate. This resulted in a complete replacement of the T65D system as distinguished from a simpler approach involving a renormalization of T65D parameters to reflect the new dosimetry. The proposed dosimetry system for RERF and the plan for implementation was accepted by the Department of Energy (DOE) Working Group on A-bomb Dosimetry chaired by Dr. R.F. Christy. The dosimetry system plan was also presented to the binational A-bomb dosimetry review groups for critical comment and was discussed at joint US-Japan workshop. A prototype dosimetry system incorporating preliminary dosimetry estimates and applicable to only a limited set of A-bomb survivors was installed on the RERF computer system in the fall of 1984. This system was successfully operated at RERF and provided an initial look at the impact of

  8. Dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  9. Type tests to the automatic system of thermoluminescent dosimetry acquired by the CPHR for personnel dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Pernas S, R. [Centro de Proteccion e Higiene de las Radiaciones (CPHR), Calle 20, No. 4113 e/ 41 y 47, Miramar, Ciudad de la Habana (Cuba)]. e-mail: daniel@cphr.edu.cu

    2005-07-01

    The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF: Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

  10. Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Pernas S, R.; Martinez G, A. [Centro de Proteccion e Higiene de las Radiaciones (CPHR), Calle 20 No. 4113 e/41 y 47. Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba)

    2006-07-01

    The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

  11. Characterising an aluminium oxide dosimetry system.

    Science.gov (United States)

    Conheady, Clement F; Gagliardi, Frank M; Ackerly, Trevor

    2015-09-01

    In vivo dosimetry is recommended as a defence-in-depth strategy in radiotherapy treatments and is currently employed by clinics around the world. The characteristics of a new optically stimulated luminescence dosimetry system were investigated for the purpose of replacing an aging thermoluminescence dosimetry system for in vivo dosimetry. The stability of the system was not sufficient to satisfy commissioning requirements and therefore it has not been released into clinical service at this time.

  12. Thermoluminescence dosimetry environmental monitoring system

    International Nuclear Information System (INIS)

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  13. A microcomputer controlled thermoluminescence dosimetry system

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  14. Sizewell B Power Station control dosimetry system

    International Nuclear Information System (INIS)

    Renn, G.

    1995-01-01

    Sizewell B Power Station is the first Pressurized Water Reactor (PWR) built in the UK for commercial electricity production. An effective control dosimetry system is a crucial tool, in allowing the station to assess its radiological performance against targets. This paper gives an overview of the control dosimetry system at Sizewell B and describes early operating experience with the system. (UK)

  15. Dosimetry system of the RB reactor

    International Nuclear Information System (INIS)

    Lolic, B.; Vukadin, D.

    1962-01-01

    Although RB reactor is operated at very low power levels, safety and dosimetry systems have high importance. This paper shows detailed dosimetry system with fundamental typical components. Estimated radiation doses dependent on reactor power are given at some characteristic points in the rooms nearby reactor

  16. Computerized dosimetry management systems within EDF

    International Nuclear Information System (INIS)

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  17. Rational system of radiation dosimetry

    International Nuclear Information System (INIS)

    Katoh, K.; Tada, J.

    1996-01-01

    Radiation doses are the most important subject to the sciences relating to the effects of ionizing radiation on matter. Since any science at all must stand on the quantitative description of causality, uses of physical quantities as the measures are indispensable. The current system of radiation dosimetry is built on the fundamental dose of the absorbed dose, which is defined as the 'energy imparted' density, and for practical convenience various weighted absorbed doses are introduced as subsidiary. However, it has been pointed out that these quantities lack adequacy inherently as a measure of causes, in addition to the insufficiency of the specification of the concept. Firstly, separation of the quantities of radiation field and of the dose is not possible, since both quantities are deeply related to the same microscopic constituents, i.e., electrons. Secondly, the value of the absorbed dose cannot be fixed at the moment of irradiation. Since the absorbed dose is a quantity of interaction product of radiation and matter, the values of the dose cannot be fixed instantaneously. Thirdly, it is not easy to envision the physical entity of the quantity from the definition. The form of existence of the 'imparted' energy is not clear in the current definition. These defects can not be removed as long as an interaction product is adopted as the dose quantity. In this paper, the authors present a prescription to solve these problems. (author)

  18. Chemical dosimetry system for criticality accidents.

    Science.gov (United States)

    Miljanić, Saveta; Ilijas, Boris

    2004-01-01

    Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.

  19. Dosimetry systems in nuclear power stations

    International Nuclear Information System (INIS)

    Weidmann, U.

    1992-01-01

    In the following paper the necessity of the use of electronic dosimetry systems in nuclear power stations is presented, also encompassing the tasks which this type of systems has to fulfill. Based on examples the construction principles and the application possibilities of a PC supported system are described. 5 figs

  20. Dosimetry systems for radiation processing in Japan

    International Nuclear Information System (INIS)

    Tamura, Naoyuki

    1995-01-01

    The present situation of dosimetry systems for radiation processing industry in Japan is reviewed. For gamma-rays irradiation the parallel-plate ionization chamber in TRCRE, JAERI has been placed as a reference standard dosimeter for processing-level dose. Various solid and liquid chemical dosimeters are used as routine dosimeters for gamma processing industries. Alanine dosimeters is used for the irradiation purpose which needs precise dosimetry. For electron-beam irradiation the electron current density meter and the total absorption calorimeter of TRCRE are used for the calibration of routine dosimeters. Plastic film dosimeters, such as cellulose triacetate and radiochromic dye are used as routine dosimeters for electron processing industries. When the official traceability systems for processing-level dosimetry now under investigation is completed, the ionization chamber of TRCRE is expected to have a role of the primary standard dosimeter and the specified alanine dosimeter will be nominated for the secondary or reference standard dosimeter. (author)

  1. Study of a 3D dosimetry system response: ARCCHECK®

    Energy Technology Data Exchange (ETDEWEB)

    Mazer, Amanda C.; Yoriyaz, Hélio, E-mail: amandamazer18@gmail.com, E-mail: hyoriyaz@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Nakandakari, Marcos V.N., E-mail: marcos.sake@gmail.com [Beneficência Portuguesa de São Paulo, SP (Brazil)

    2017-07-01

    Ionizing radiation therapies have improved over the years, becoming more specific for each patient. Thereby as the treatment planning system (TPS) complexities increases, the quality assurance (QA) methods have to be in a constant evolution. One of the techniques that demand great complexity is the Volumetric Modulated Arc Therapy (VMAT). One possible way to VMAT commissioning is using 3D dosimetry systems and recently a new 3D dosimetry system called ArcCheck had been developed and commercialized mainly for VMAT quality assurance. It is water-equivalent and composed by an array of 1386 diodes arranged in a spiral pattern. Since simulation methods, like Monte Carlo method, ensure highly accurate results, MCNP (A General Monte Carlo N-Particle Transport Code System) is totally reliable for problems that involve radiation transport. This work presents a preliminary study of the 3D dosimetry system ArcCheck by developing two computational models in MCNP6. In addition, experimental measures were acquired using the ArcCheck in a Linear Accelerator and then these values were compared with the results obtained by simulations of both models. The comparisons showed good reproducibility. (author)

  2. A practical three-dimensional dosimetry system for radiation therapy

    International Nuclear Information System (INIS)

    Guo Pengyi; Adamovics, John; Oldham, Mark

    2006-01-01

    measurable region of PRESAGE trade mark sign dosimeter (∼90% of radius). The EBT and PRESAGE trade mark sign distributions agreed more closely with each other than with the calculated plan, consistent with penumbral blurring in the planning data which was acquired with an ion chamber. In summary, our results support the conclusion that the PRESAGE trade mark sign optical-CT combination represents a significant step forward in 3D dosimetry, and provides a robust, clinically effective and viable high-resolution relative 3D dosimetry system for radiation therapy

  3. The application of an automated thermoluminescence dosimetry system to environmental γ-dosimetry

    International Nuclear Information System (INIS)

    Jones, A.R.

    1977-07-01

    A personnel monitoring system comprising thermoluminescent dosimeters (TLDs) and an automatic TLD reader has been applied to environmental gamma dosimetry. For this purpose the accuracy of measurement at low exposures (10 to 100 mR) acquired over long periods (3 or 12 months) is important. To improve the accuracy and reliability of the system for this application the following steps were taken: the dosimeters were sensitized by irradiation with γ-rays and annealed while being irradiated with UV light; the sensitivity of each, identified dosimeter was measured and used to correct exposure measurements; the gasketted holders were modified to contain TLDs mounted on two identified plaques. Measurements of linearity, variability (with and without individual calibration) fading and energy dependence are presented. (author)

  4. INTEGRATED OPERATIONAL DOSIMETRY SYSTEM AT CERN.

    Science.gov (United States)

    Dumont, Gérald; Pedrosa, Fernando Baltasar Dos Santos; Carbonez, Pierre; Forkel-Wirth, Doris; Ninin, Pierre; Fuentes, Eloy Reguero; Roesler, Stefan; Vollaire, Joachim

    2017-04-01

    CERN, the European Organization for Nuclear Research, upgraded its operational dosimetry system in March 2013 to be prepared for the first Long Shutdown of CERN's facilities. The new system allows the immediate and automatic checking and recording of the dosimetry data before and after interventions in radiation areas. To facilitate the analysis of the data in context of CERN's approach to As Low As Reasonably Achievable (ALARA), this new system is interfaced to the Intervention Management Planning and Coordination Tool (IMPACT). IMPACT is a web-based application widely used in all CERN's accelerators and their associated technical infrastructures for the planning, the coordination and the approval of interventions (work permit principle). The coupling of the operational dosimetry database with the IMPACT repository allows a direct and almost immediate comparison of the actual dose with the estimations, in addition to enabling the configuration of alarm levels in the dosemeter in function of the intervention to be performed. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. New advanced TLD system for space dosimetry

    International Nuclear Information System (INIS)

    Feher, I.; Szabo, B.; Vagvoelgyi, J.; Deme, S.; Szabo, P.P.; Csoeke, A.

    1983-10-01

    A new version of the TLD reader type PILLE has been developed for space applications. The earlier compact and portable device could also be used for measurements during space flights but its range was limited. A new bulb detector with easier handling has also been developed with an upper limit of linear dose response of 10 Gy. The range of this new and more versatile reader, NA206S, (1μGy-10 Gy) is 3 orders of magnitude higher than that of the earlier system; it also has increased sensitivity and decreased mass. It can be used not only in space applications but also for environmental monitoring or even in accident dosimetry. The measured dose value is displayed on a four-digit display with automatic range switch. Another new version, the NA206E, has been developed for environmental dosimetry; it can be operated from a battery or from the mains. (author)

  6. An automated thermoluminescence dosimetry (TLD) system

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.

    1979-01-01

    In the Health Physics Division of the Eindhoven University of Technology work is going on in developing an automated TLD-system. Process automization, statistical computation, dose calculation as well as dose recording are carried out, using a microcomputer and floppy disk unit. The main features of this TLD-system are its low costs, flexibility, easy to operate, and the feasibility for use in routine dosimetry as well as in complex TLD research. Because of its modular set-up several components of the system are multifunctional in other operations. The system seems suited for medium sized Health Physics groups. (Auth.)

  7. Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  8. Performance of dichromate dosimetry systems in calibration and dose intercomparison

    International Nuclear Information System (INIS)

    Bof, E.S.; Smolko, E.

    1999-01-01

    This report presents the results of the High Dose Dosimetry Laboratory of Argentina during ten years of international intercomparisons for high dose with the International Dose Assurance Service (IDAS) of the IAEA, using the standard high dose dichromate dosimetry system, and the results of a high dose intercomparison regional exercise in which our Laboratory acted as a reference laboratory, using the standard high dose and low dose dichromate dosimetry system. (author)

  9. Dosimetry

    International Nuclear Information System (INIS)

    Rezende, D.A.O. de

    1976-01-01

    The fundamental units of dosimetry are defined, such as exposure rate, absorbed dose and equivalent dose. A table is given of relative biological effectiveness values for the different types of radiation. The relation between the roentgen and rad units is calculated and the concepts of physical half-life, biological half-life and effective half-life are discussed. Referring to internal dosimetry, a mathematical treatment is given to β particle-and γ radiation dosimetry. The absorbed dose is calculated and a practical example is given of the calculation of the exposure and of the dose rate for a gama source [pt

  10. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  11. Dosimetry system of the RB reactor; Dozimetarski sistem reaktora RB

    Energy Technology Data Exchange (ETDEWEB)

    Lolic, B; Vukadin, D [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1962-07-01

    Although RB reactor is operated at very low power levels, safety and dosimetry systems have high importance. This paper shows detailed dosimetry system with fundamental typical components. Estimated radiation doses dependent on reactor power are given at some characteristic points in the rooms nearby reactor.

  12. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, gamma) process in Na sup 2 sup 3 , giving rise to Na sup 2 sup 4 , which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na sup 2 sup 4 , is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na sup 2 sup 3 in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na sup 2 sup 4 /Na sup 2 sup 3 in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R sub B reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzmann transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given

  13. Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G S; Ritchie, R H; Sanders, F W; Reinhardt, P W; Auxier, J A; Wagner, E B; Callihan, A D; Morgan, K Z [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-01

    The methods of dosimetry used for investigation of the doses received by the individuals exposed in the Yugoslav accident were essentially those used in connection with the Oak Ridge Y-12 accident. An outline of the general scheme is as follows: When fast neutrons enter the human body, most of these are moderated to thermal energy and a small fraction of these are captured by a (n, {gamma}) process in Na{sup 23}, giving rise to Na{sup 24}, which by virtue of its emission of high-energy gamma rays with a half life of 14.8 h, is easily detected. It has been shown that the probability of capture, making Na{sup 24}, is not a strong function of the energy of the fast neutrons and that the probability of capture for neutrons is higher in the fast region than in the thermal region. Thus, the uniform distribution of Na{sup 23} in the human body provides an excellent means of normalizing the neutron exposure of an individual. in particular, for a given neutron energy spectrum the fast neutron dose is proportional to the ratio Na{sup 24}/Na{sup 23} in the body or in the blood system. This method of normalization is quite important in the dosimetry of radiation accidents since no assumptions need be made about the exact location of an individual at the time of the energy release. The importance of this fact can be made clear by reference to the Y-12 accident where it was shown by calculation of the neutron dose based on the known number of fissions and the stated location of the individual that one of the surviving individuals would have received a dose several times the lethal value. To accomplish the measurements described, the zero power R{sub B} reactor was operated in two ranges of power level, 'low' power and 'high 'power. Neutron leakage spectrum was obtained by multigroup approximation of the Boltzman transport equation. Prompt gamma rays from fission products, from capture in the moderator and fuel cladding as well as in tank walls are given. A summary of the 4{pi

  14. Semiconductor dosimetry system for gamma and neutron radiation

    International Nuclear Information System (INIS)

    Savic, Z.; Pavlovic, Z.

    1995-01-01

    The semiconductor dosimetry system for gamma and neutron radiation based on pMOS transistor and PIN diode is described. It is intended for tactical or accidental personal dosimetry. The production steps are given. The temperature, dose and time (fading) response are reported. Hardware and software requirements which are needed for obtaining the desired measurement error are pointed. (author)

  15. Reassessment of the RERF dosimetry system - overview of the new dosimetry system DS02

    International Nuclear Information System (INIS)

    Young, R.W.

    2003-01-01

    This paper describes a major reassessment of the system used at the Radiation Effects Research Foundation (RERF) to determine radiation doses for atomic-bomb survivors. This effort has resolved the neutron discrepancy in RERF dosimetry, and has defined the parameters for a replacement system for survivor dose calculation. A Joint US-Japan Working Group undertook a comprehensive evaluation of the calculations that comprise the RERF dosimetry system and the measurements used to verify those calculations. During the course of this reassessment, the working groups, with members from American, German and Japanese universities and national laboratories, have recomputed all of the Hiroshima and Nagasaki radiation calculations, made fast-neutron and low-background thermal-neutron measurements, upgraded the calculation of the radiation shielding provided by terrain and large buildings, and conducted a comprehensive reassessment of all radiation measurements. The new calculations produced during this reassessment agree with both gamma and neutron measurements out to distances from the detonations at which in-situ measurements become indistinguishable from background, effectively resolving the long-standing neutron dose discrepancy. The calculations that produce this agreement are the basis for the new DS02 dosimetry system. New calculations and measurements confirmed the yield and epicenter for the Nagasaki detonation while refining both these values for Hiroshima. Current measurements and calculations confirm a 21-kiloton-yield for the Nagasaki bomb and a burst point to within two meters of previous assessments. In Hiroshima, the estimated yield has been increased from 15 kt to 16 kt and the epicenter has been repositioned 20 meters higher and 15 meters to the west. While these refined parameters make the dosimetry system more accurate and users of the system more confident in the results, the calculated dose to survivors will change only about ten percent

  16. The Bristol University neutron dosimetry system

    International Nuclear Information System (INIS)

    Worley, A.; Fews, A.P.; Henshaw, D.L.

    1987-01-01

    The neutron dosimetry system developed at Bristol is based on recording recoil proton tracks in conventionally etched PADC plastic using a fully automated image analysis system. Two features contribute to the achievement of a low dose threshold: high quality plastic is manufactured and undergoes extensive quality control tests prior to acceptance for use in dosimetry, and a readout system with high efficiency for rejecting background events is used. The principal dosemeter that has been developed consists of three orthogonal elements, each containing two 3 cm x 1 cm plastics on either side of a polyethylene radiator. On each plastic an area of 0.15 cm 2 is scanned giving a total active area of 0.90 cm 2 . Each plastic is coded for manual identification and for computer recognition. The track counts from the six plastics are added with different weightings to achieve a measure of dose which is independent of irradiation direction when worn on the body. The device has been calibrated using monoenergetic neutrons in the range 100 keV to 14.7 MeV at NPL, and using the recent CENDOS exposure. If the track counts are added without weighting, the device has a nominal response of 120 tracks cm -2 .mSv -1 and an energy threshold at 200 keV. Taken together with a background of 20 track cm -2 , a dose threshold of around 80μSv is implied. A simpler dosemeter, using a single plastic/radiator combination, may also be considered. If a 1 cm 2 device is used for normal incidence exposure, the dose threshold is calculated to be 25 μSv. (author)

  17. Integrating the DLD dosimetry system into the Almaraz NPP Corporative Database

    International Nuclear Information System (INIS)

    Gonzalez Crego, E.; Martin Lopez-Suevos, C.

    1996-01-01

    The article discusses the experience acquired during the integration of a new MGP Instruments DLD Dosimetry System into the Almaraz NPP corporative database and general communications network, following a client-server philosophy and taking into account the computer standards of the Plant. The most important results obtained are: Integration of DLD dosimetry information into corporative databases, permitting the use of new applications Sharing of existing personnel information with the DLD dosimetry application, thereby avoiding the redundant work of introducing data and improving the quality of the information. Facilitation of maintenance, both software and hardware, of the DLD system. Maximum explotation, from the computer point of view, of the initial investment. Adaptation of the application to the applicable legislation. (Author)

  18. Use of data libraries in dosimetry control systems

    International Nuclear Information System (INIS)

    Babenko, V.V.; Babenko, M.I.; Kazimirov, A.S.

    2002-01-01

    Analysis, prediction and planning of dose loads, adequacy in dose management of personnel, evaluation of expediency and sufficiency of existing radiation protection system can be realized with the help of database system of dosimetry control in 'Ukrytie'-shelter

  19. Development a high-resolution radiation dosimetry system based on Fricke solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vedelago, J. [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Mattea, F. [Universidad Nacional de Cordoba, Facultad de Ciencias Quimicas, Departamento de Quimica Organica, Ciudad Universitaria, 5000 Cordoba (Argentina); Valente, M., E-mail: josevedelago@gmail.com [Instituto de Fisica E. Gaviola, Oficina 102 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  20. Development a high-resolution radiation dosimetry system based on Fricke solutions

    International Nuclear Information System (INIS)

    Vedelago, J.; Mattea, F.; Valente, M.

    2014-08-01

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  1. Characterization of a thermoluminiscence personnel dosimetry system

    International Nuclear Information System (INIS)

    Vazquez Lopez, C.; Saez, J.C.; Labarta, T.

    1989-01-01

    Various tests carried out to characterize a Thermoluminiscence Personnel Dosimetry Automatic System, based on the optical heating of a multielement dosemeter are presented. The dosemeter consists of Lithium Borate (Copper) and Calcium Sulphate (Thallium) phosphors. The Dosimetric System shows some outstanding features, such as its simplicity (no aditional annealing procedures are required), its short reading cycle (160 TLD per hour and its data handling capabilities (RS-232C and Parallel Printer digital ports and four analigic outputs for Glow Curve Adquisition). The tests performed have been designed to conform with the different existing international Standards and Recommendations (ANSI: N13.11-1983; IEC:Draft 45B-1987, ISO:DP 8034-1984) The new radiological quantities (I.C.R.U.-19855) have been used for calibration. The results obtained (linearity, repeatibility, detection threshold, residue, stability of stored information, etc) show the optimum performance of this dosimetric system in its aplication to routine personnel dose monitoring. Based on the dosemeter energy discriminating response, an algorithm for dose assesment has been developed. The method allows personal dose calculations within 10% and gives valuable information on the quality and energy of incident radiation, for photons from 30 to 2000 keV and for Beta penetrating radiation (Sr/Y, U). (Author)

  2. Characterization and evaluation studies on some JAERI dosimetry systems

    International Nuclear Information System (INIS)

    Kojima, T.; Sunaga, H.; Tachibana, H.; Takizawa, H.; Tanaka, R.

    2000-01-01

    Characterization and evaluation studies were carried out on some JAERI dosimetry systems, mainly alanine-ESR, in terms of the influence on the dose response of parameters such as orientation at ESR analysis, and the temperature during irradiation and analysis. Feasibility study for application of these dosimetry systems to electrons with energies lower than 4 MeV and bremsstrahlung (X rays) was also performed parallel to their reliability check through international dose intercomparison. (author)

  3. The personnel dosimetry record keeping system at AEE Winfrith

    International Nuclear Information System (INIS)

    Gill, D.W.

    1979-09-01

    Since May 1978 the exposure of personnel to external radiation has been assessed by Thermoluminescent Dosimetry, (TLD). The dosemeter consists of a TLD card similar to that used by the National Radiological Protection Board, held in a plastic badge designed at AEE Winfrith, and used in conjunction with a D A Pitman Ltd Type 605 Automatic Reader. The report describes the dosemeter, the operation of the dosimetry service and the system for maintaining a computerised record keeping system. (author)

  4. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  5. Determining the lower limit of detection for personnel dosimetry systems

    International Nuclear Information System (INIS)

    Roberson, P.L.; Carlson, R.D.

    1992-01-01

    A simple method for determining the lower limit of detection (LLD) for personnel dosimetry systems is described. The method relies on the definition of a critical level and a detection level. The critical level is the signal level above which a result has a small probability of being due to a fluctuation of the background. All results below the critical level should not be reported as an indication of a positive result. The detection level is the net signal level (i.e., dose received) above which there is a high confidence that a true reading will be detected and reported as a qualitatively positive result. The detection level may be identified as the LLD. A simple formula is derived to allow the calculation of the LLD under various conditions. This type of formula is being used by the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry. Participants in either the National Voluntary Laboratory Accreditation Program (NVLAP) for personnel dosimetry or DOELAP can use performance test results along with a measurement of background levels to estimate the LLDs for their dosimetry system. As long as they maintain their dosimetry system such that the LLDs are less than half the lower limit of the NVLAP or DOELAP test exposure ranges, dosimetry laboratories can avoid testing failures due to poor performance at very low exposures

  6. System Acquires Data On Reactivities Of Foams

    Science.gov (United States)

    Walls, Joe T.

    1994-01-01

    Data-acquisition and -plotting system, called DAPS(TM), developed enabling accurate and objective determination of physical properties related to reactivities of polyurethane and polyisocyanurate foams. Automated, computer-controlled test apparatus that acquires data on rates of rise, rise profiles, exothermic temperatures, and internal pressures of foams prepared from both manual and machine-mixed batches. Data used to determine minute differences between reaction kinetics and exothermic profiles of foam formulations, properties of end products which are statistically undifferentiated.

  7. An experimental system for thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Perry, K.E.G.; George, E.

    1965-08-01

    A thermoluminescent dosimeter (T.L.D.) reader has been developed for experimental investigations on the use of lithium fluoride for 'finger tip' dosimetry. The design of the reader is based on the maximum use of standard electronic units in the A.E.R.E. Type 2000 series but some new unit development has been necessary. The reader gives improved experimental facilities over present commercially-available designs. The technique for 'finger-tip' dosimetry is described and the initial experimental results are given. (author)

  8. Dosimetry quality assurance in Martin Marietta Energy Systems' centralized external dosimetry system

    International Nuclear Information System (INIS)

    Souleyrette, M.L.

    1992-01-01

    External dosimetry needs at the four Martin Marietta Energy Systems facilities are served by Energy Systems Centralized External Dosimetry System (CEDS). The CEDS is a four plant program with four dosimeter distribution centers and two dosimeter processing centers. Each plant has its own distribution center, while processing centers are located at ORNL and the Y-12 Plant. The program has been granted accreditation by the Department of Energy Laboratory Accreditation Program (DOELAP). The CEDS is a TLD based system which is responsible for whole-body beta-gamma, neutron, and extremity monitoring. Beta-gamma monitoring is performed using the Harshaw/Solon Technologies model 8805 dosimeter. Effective October 1, 1992 the standard silver mylar has been replaced with an Avery mylar foil blackened on the underside with ink. This was done in an effort to reduce the number of light induced suspect readings. At this time we have little operational experience with the new blackened mylars-The CEDS neutron dosimeter is the Harshaw model 8806B. This card/holder configuration contains two TLD-600/TLD-700 chip pairs; one pair is located beneath a cadmium filter and one pair is located beneath a plastic filter. In routine personnel monitoring the CEDS neutron dosimeter is always paired with a CEDS beta-gamma dosimeter.The CEDS extremity dosimeter is composed of a Harshaw thin TLD-700 dosiclip placed inside a Teledyne RB-4 finger sachet. The finger sachet provides approximately 7 mg/cm 2 filtration over the chip. A teflon ring surrounds the dosiclip to help prevent tearing of the vinyl sachet

  9. A set of dosimetry systems for electron beam irradiation

    International Nuclear Information System (INIS)

    Lin Min; Lin Jingwen; Chen Yundong; Li Huazhi; Xiao Zhenhong; Gao Juncheng

    1999-01-01

    To follow the rapid development of radiation processing with electron beams, it is urgent to set up a set of dosimetric standards to provide Quality Assurance (QA) of electron beam irradiation and unify the values of the quality of the absorbed dose measurements for electron beams. This report introduces a set of dosimetry systems established in Radiometrology Center of China Institute of Atomic Energy (RCCIAE), which have been or will be used as dosimetric standards in the Nuclear Industry System (NIS) in China. For instance, the potassium (silver) dichromate and ceric-cerous sulfate dosimetry systems will be used as standard dosimeters, while alanine-ESR dosimetry system as a transfer dosimeter, and FJL-01 CTA as a routine dosimeter. (author)

  10. Electrical Signaling, Photosynthesis and Systemic Acquired Acclimation

    Directory of Open Access Journals (Sweden)

    Magdalena Szechyńska-Hebda

    2017-09-01

    Full Text Available Electrical signaling in higher plants is required for the appropriate intracellular and intercellular communication, stress responses, growth and development. In this review, we have focus on recent findings regarding the electrical signaling, as a major regulator of the systemic acquired acclimation (SAA and the systemic acquired resistance (SAR. The electric signaling on its own cannot confer the required specificity of information to trigger SAA and SAR, therefore, we have also discussed a number of other mechanisms and signaling systems that can operate in combination with electric signaling. We have emphasized the interrelation between ionic mechanism of electrical activity and regulation of photosynthesis, which is intrinsic to a proper induction of SAA and SAR. In a special way, we have summarized the role of non-photochemical quenching and its regulator PsbS. Further, redox status of the cell, calcium and hydraulic waves, hormonal circuits and stomatal aperture regulation have been considered as components of the signaling. Finally, a model of light-dependent mechanisms of electrical signaling propagation has been presented together with the systemic regulation of light-responsive genes encoding both, ion channels and proteins involved in regulation of their activity. Due to space limitations, we have not addressed many other important aspects of hormonal and ROS signaling, which were presented in a number of recent excellent reviews.

  11. System of data management in 'Dosis' personal dosimetry

    International Nuclear Information System (INIS)

    Manzano de Armas, Jose; Diaz Bernal, Efren; Capote Ferrera, Eduardo; Molina Perez, Daniel; Lopez Bejerano, Gladys

    2001-01-01

    The storage and control of the data of a service of personal dosimetry is a task that requires specify care in data handling and manipulation. This activity becomes more annoying of making manually when the volume of users of the service is significant. The External Dosimetric Laboratory of the Center for Radiation Protection and Hygiene has developed a system of administration of data that allows the storage, control and analysis of the data generated by the Service of Personal Dosimetry in an efficient and reliable way. This paper describes the characteristics of the System for Administration of Data in Personal Dosimetry 'Dosis', as well as their design and programming. The importance of this System for the laboratory and the advantages of their application are described. The characteristics of the different modules are also described. (author)

  12. Dosicard: on-site evaluation of a new individual dosimetry system

    International Nuclear Information System (INIS)

    Delacroix, D.; Guelin, M.; Lyron, C.; Feraud, J.P.

    1995-01-01

    Dosicard is a new individual dosimetry system developed to monitor personnel working in the following fields: civil and military nuclear applications, medical environments and research centres: it can also be used to monitor mobile personnel. The system is based on the use of a credit-card sized format electronic badge. The associated computer environment enables management of the dosimetric data acquired. The characteristics of the system are presented in this paper together with an evaluation of the results of six month's use in a nuclear research centre. (author)

  13. Precision dosimetry system suited for low temperature radiation damage experiments

    DEFF Research Database (Denmark)

    Andersen, H.H.; Hanke, C.C.; Sørensen, H.

    1967-01-01

    A calorimetric system for dosimetry on a beam of charged particles is described. The calorimeter works at liquid helium temperature. The total dose may be measured with an accuracy of 0.3%, and the dose per area with 0.4%. No theoretical corrections are needed. © 1967 The American Institute...

  14. The reliability of the systems of personal dosimetry

    International Nuclear Information System (INIS)

    Gullberg, O.; Lindborg, L.

    1982-01-01

    The dosimeters of companies and institutions have been irradiated at various energy and dose equivalent levels. Systematic and coincident errors in measurement are presented. The results show that relatively large systematic errors can be made by both the thermoluminescent and film systems. Various techniques to judging the quality of the dosimetry are discussed. (G.B.)

  15. Patient dosimetry quality assurance program with a commerical diode system

    International Nuclear Information System (INIS)

    Lee, P.C.; Sawicka, J.M.; Glasgow, G.P.

    1994-01-01

    The purpose was to evaluate a commercial silicone diode dosimeter for a patient dosimetry quality assurance program. The diode dosimeter was calibrated against an ion chamber, and percentage depth dose, linearity, anisotrophy, virtual source position, and field size factor studies were performed. Correction factors for lack of full scatter medium in the diode entrance and exit dose measurements were acquired. Dosimetry equations were proposed for calculation of dose delivered at isocenter. Diode dose accuracy and reproducibility were tested on phantom and on four patients. A patient dosimetry quality assurance program based on diode-measured dose was instituted and patient dose data were collected. Diode measured percentage depth dose and field factors agreed to within 3% with those measured with an ion chamber. The diode exhibited less than 1.7% angular dose anisotrophy and less than 0.5% nonlinearity up to 4 Gy. Diode dose measurements in phantom showed that the calculated doses differed from the prescribed dose by less than 1.%; the diode exhibited a daily dose reproducibility of better than 0.2%. On four selected patients, the measured dose reproducibility was 1.5%; the average calculated doses were all within ± 7% of the prescribed doses. For 33 of 40 patients treated with a 6 MW beam, measured doses were within ± 7% of the prescribed doses. For 11 out of 12 patients, a second repeat measurements yielded doses within ± 7% of the prescribed doses. The proposed diode-based patient dosimetry quality assurance program with dose tolerance at ± 7% is simple and feasible. It is capable of detecting certain serious treatment errors such as incorrect daily dose greater than 7%, incorrect wedge use, incorrect photon energy and patient setup errors involving some incorrect source-to-surface-distance vs. source-to-axis-distance treatments. 13 refs., 5 figs., 5 tabs

  16. Recent progress in application of JAERI alanine/ESR dosimetry system

    International Nuclear Information System (INIS)

    Kojima, T.

    1995-01-01

    Feasibility studies of application of JAERI alanine/ESR dosimetry system were performed on radiotherapy level dosimetry, low dose-rate dosimetry for residual life estimation of cable insulators used in nuclear power facilities, and dose monitoring for electron processing. (author)

  17. EURADOS intercomparison 2006 to harmonise European early warning dosimetry systems

    International Nuclear Information System (INIS)

    Dombrowski, H.; Neumaier, S.; Thompson, I. M. G.; Wissmann, F.

    2009-01-01

    In 2006, the European Radiation Dosimetry (EURADOS) Working Group on Environmental Radiation Monitoring (WG3) organised a third European intercomparison of dosimetry systems operated in national early warning networks. Similar to the intercomparisons in 1999 and 2002, the main aim of this exercise was to support the process of harmonisation of area monitoring in Europe by providing the network operators with basic information on the calibration and performance of their dosimetry systems. In order to characterise these systems, their following basic parameters were investigated: the response to terrestrial and cosmic radiation, the detectors' inherent background, the response at low dose rates, the energy dependence of the response as well as the sensitivity of the detector systems to small changes of the dose rate in a natural environmental radiation field. In the 2006 EURADOS intercomparison, scientists from seven countries participated to study the characteristics of 11 detector systems. All results are presented in terms of the operational quantity ambient dose equivalent, H * (10). The advent of this quantity has caused the development of new detector systems for area monitoring. Some of these new systems participated in a EURADOS intercomparison for the first time. The results are consistently presented together with uncertainties so that statistical effects can be distinguished from real detector features, which improves the interpretation of the results. By using the results of this intercomparison, some detectors were re-calibrated. The achievable improvements concerning harmonisation in dose-rate measurements in the natural environment are discussed. (authors)

  18. Next-generation systemic acquired resistance.

    Science.gov (United States)

    Luna, Estrella; Bruce, Toby J A; Roberts, Michael R; Flors, Victor; Ton, Jurriaan

    2012-02-01

    Systemic acquired resistance (SAR) is a plant immune response to pathogen attack. Recent evidence suggests that plant immunity involves regulation by chromatin remodeling and DNA methylation. We investigated whether SAR can be inherited epigenetically following disease pressure by Pseudomonas syringae pv tomato DC3000 (PstDC3000). Compared to progeny from control-treated Arabidopsis (Arabidopsis thaliana; C(1)), progeny from PstDC3000-inoculated Arabidopsis (P(1)) were primed to activate salicylic acid (SA)-inducible defense genes and were more resistant to the (hemi)biotrophic pathogens Hyaloperonospora arabidopsidis and PstDC3000. This transgenerational SAR was sustained over one stress-free generation, indicating an epigenetic basis of the phenomenon. Furthermore, P(1) progeny displayed reduced responsiveness of jasmonic acid (JA)-inducible genes and enhanced susceptibility to the necrotrophic fungus Alternaria brassicicola. This shift in SA- and JA-dependent gene responsiveness was not associated with changes in corresponding hormone levels. Instead, chromatin immunoprecipitation analyses revealed that SA-inducible promoters of PATHOGENESIS-RELATED GENE1, WRKY6, and WRKY53 in P(1) plants are enriched with acetylated histone H3 at lysine 9, a chromatin mark associated with a permissive state of transcription. Conversely, the JA-inducible promoter of PLANT DEFENSIN1.2 showed increased H3 triple methylation at lysine 27, a mark related to repressed gene transcription. P(1) progeny from the defense regulatory mutant non expressor of PR1 (npr1)-1 failed to develop transgenerational defense phenotypes, demonstrating a critical role for NPR1 in expression of transgenerational SAR. Furthermore, the drm1drm2cmt3 mutant that is affected in non-CpG DNA methylation mimicked the transgenerational SAR phenotype. Since PstDC3000 induces DNA hypomethylation in Arabidopsis, our results suggest that transgenerational SAR is transmitted by hypomethylated genes that direct priming

  19. The Martin Marietta Energy Systems personnel neutron dosimetry program

    International Nuclear Information System (INIS)

    McMahan, K.L.

    1991-01-01

    Martin Marietta Energy Systems, Inc. (Energy Systems), manages five sites for the US Department of Energy. Personnel dosimetry for four of the five sites is coordinated through a Centralized External Dosimetry System (CEDS). These four sites are the Oak Ridge National Laboratory (ORNL), the Oak Ridge Y-12 Plant (Y-12), the Oak Ridge K-25 Site (K-25), and the Paducah Gaseous Diffusion Plant (PGDP). The fifth Energy Systems site, Portsmouth Gaseous Diffusion Plant, has an independent personnel dosimetry program. The current CEDS personnel neutron dosimeter was first issued in January 1989, after an evaluation and characterization of the dosimeters' response in the workplaces was performed. For the workplace characterization, Energy Systems contracted with Pacific Northwest Laboratory (PNL) to perform neutron measurements at selected locations at ORNL and Y-12. K-25 and PGDP were not included because their neutron radiation fields were similar to others already planned for characterization at ORNL and Y-12. Since the initial characterization, PNL has returned to Oak Ridge twice to perform follow up measurements, and another visit is planned in the near future

  20. Textbook of dosimetry. 4. ed.

    International Nuclear Information System (INIS)

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  1. Secondary standard dosimetry system with automatic dose/rate calculation

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Bernhart, J.; Stehno, G.; Klosch, W.

    1980-01-01

    A versatile and automated secondary standard instrument has been designed for quick and accurate dose/rate measurement in a wide range of radiation intensity and quality (between 1 μR and 100 kR; 0.2 nC/kg - 20C/kg) for protection and therapy level dosimetry. The system is based on a series of secondary standard ionization chambers connected to a precision digital current integrator with microprocessor circuitry for data evaluation and control. Input of measurement parameters and calibration factors stored in an exchangeable memory chip provide computation of dose/rate values in the desired units. The ionization chambers provide excellent long-term stability and energy response and can be used with internal check sources to test validity of calibration. The system is a useful tool particularly for daily measurements in a secondary standard dosimetry laboratory or radiation therapy center. (H.K.)

  2. In Vitro Exposure Systems and Dosimetry Assessment Tools ...

    Science.gov (United States)

    In 2009, the passing of The Family Smoking Prevention and Tobacco Control Act facilitated the establishment of the FDA Center for Tobacco Products (CTP) and gave it regulatory authority over the marketing, manufacture and distribution of tobacco products, including those termed “modified risk”. On 4-6 April 2016, the Institute for In Vitro Sciences, Inc. (IIVS) convened a workshop conference titled “In Vitro Exposure Systems and Dosimetry Assessment Tools for Inhaled Tobacco Products” to bring together stakeholders representing regulatory agencies, academia, and industry to address the research priorities articulated by the FDA CTP. Specific topics were covered to assess the status of current in vitro smoke and aerosol/vapor exposure systems, as well as the various approaches and challenges to quantifying the complex exposures, in in vitro pulmonary models developed for evaluating adverse pulmonary events resulting from tobacco product exposures. The four core topics covered were, 1) Tobacco Smoke And E-Cigarette Aerosols, 2) Air-Liquid Interface-In Vitro Exposure Systems, 3) Dosimetry Approaches For Particles And Vapors; In Vitro Dosimetry Determinations and 4) Exposure Microenvironment/Physiology Of Cells. The two and a half day workshop included presentations from 20 expert speakers, poster sessions, networking discussions, and breakout sessions which identified key findings and provided recommendations to advance these technologies. Here, we will re

  3. Reassessment of the atomic bomb radiation dosimetry for Hiroshima and Nagasaki. Dosimetry system 2002. DS02. Volume 1

    International Nuclear Information System (INIS)

    Young, Robert W.; Kerr, George D.

    2005-01-01

    The extensive efforts to review the dosimetry of the atomic-bomb survivors and formulate the new dosimetry system DS02 have been greatly welcomed by the Radiation Effects Research Foundation (RERF). This accomplishment is a fine tribute to the importance of the epidemiological studies being conducted at RERF. No other study is so informative of the effects of radiation on human health. The gracious participation in the RERF program by the atomic-bomb survivors allows us to contribute to the well being of these individuals, and the high quality of the data obtained allows the RERF results to feature so prominently in the formulation of international guidelines for radiation protection. Such a great effort to improve and substantiate the dosimetry would not otherwise have been justified. RERF greatly appreciates the independent work of the U.S. and Japanese Working Groups on the atomic-bomb dosimetry and the review by the Joint Senior Review Group of this overall effort. We are assured that unbiased development of the new dosimetry system will reflect well in its application in the RERF epidemiology study. The documentation included in this report will serve as reference for the many deliberations concluded. The title publications are divided into 2 volumes. This is the first volume. The 8 of the reports in each chapter are indexed individually. (J.P.N.)

  4. Reassessment of the atomic bomb radiation dosimetry for Hiroshima and Nagasaki. Dosimetry system 2002. DS02. Volume 2

    International Nuclear Information System (INIS)

    Young, Robert W.; Kerr, George D.

    2005-01-01

    The extensive efforts to review the dosimetry of the atomic-bomb survivors and formulate the new dosimetry system DS02 have been greatly welcomed by the Radiation Effects Research Foundation (RERF). This accomplishment is a fine tribute to the importance of the epidemiological studies being conducted at RERF. No other study is so informative of the effects of radiation on human health. The gracious participation in the RERF program by the atomic-bomb survivors allows us to contribute to the well being of these individuals, and the high quality of the data obtained allows the RERF results to feature so prominently in the formulation of international guidelines for radiation protection. Such a great effort to improve and substantiate the dosimetry would not otherwise have been justified. RERF greatly appreciates the independent work of the U.S. and Japanese Working Groups on the atomic-bomb dosimetry and the review by the Joint Senior Review Group of this overall effort. We are assured that unbiased development of the new dosimetry system will reflect well in its application in the RERF epidemiology study. The documentation included in this report will serve as reference for the many deliberations concluded. The title publications are divided into 2 volumes. This is the second volume. The 29 of the reports in each chapter are indexed individually. (J.P.N.)

  5. The PADE dosimetry system at the Brokdorf nuclear power station

    International Nuclear Information System (INIS)

    Poetter, Karl-Friedrich; Eckelmann, Joerg; Kuegow, Mario; Spahn, Werner; Franz, Manfred

    2002-01-01

    The PADE program system is used in nuclear power plants for personnel and workplace dosimetry and for managing access to the controlled area. On-line interfaces with existing dose determination systems allow collection, surveillance and evaluation functions to be achieved for person-related and workplace-related dose data. This is managed by means of open, non-proprietary communication of PADE with the computer system coupled via interfaces. In systems communication, PADE is limited to main interventions into outside systems, thus ensuring flexible adaptation to existing systems. As a client-server solution, PADE has been developed on the basis of an ORACLE-8 database; the version presented here runs on a Windows NT server. The system described has been used at the Brokdorf Nuclear Power Station since early 2000 and has so far reliably managed more than one million individual access movements of more than 6 000 persons. It is currently being integrated into a comprehensive plant operations management system. Among other things, PADE offers a considerable development potential for a tentatively planned future standardization of parts of the dosimetry systems in German nuclear power plants and for the joint management of in-plant and official dose data. (orig.) [de

  6. Guide for selection and calibration of dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    2002-01-01

    This guide covers the basis for selecting and calibrating dosimetry systems used to measure absorbed dose in gamma ray or X-ray fields and in electron beams used for radiation processing. It discusses the types of dosimetry systems that may be employed during calibration or on a routine basis as part of quality assurance in commercial radiation processing of products. This guide also discusses interpretation of absorbed dose and briefly outlines measurements of the uncertainties associated with the dosimetry. The details of the calibration of the analytical instrumentation are addressed in individual dosimetry system standard practices. The absorbed-dose range covered is up to 1 MGy (100 Mrad). Source energies covered are from 0.1 to 50 MeV photons and electrons. This guide should be used along with standard practices and guides for specific dosimetry systems and applications covered in other standards. Dosimetry for radiation processing with neutrons or heavy charged particles is not covered in this guide

  7. Design of a system for neutrons dosimetry

    International Nuclear Information System (INIS)

    Ceron, P.; Rivera, T.; Paredes G, L.; Azorin, J.; Sanchez, A.; Vega C, H. R.

    2014-08-01

    At the present time diverse systems of detection of neutrons exist, as proportional counters based on BF 3 , He 3 and spectrometers of Bonner spheres. However, the cost and the complexity of the implementation of these systems put them far from the reach for dosimetric purposes. For these reasons a system of neutrons detection composed by a medium paraffin moderator that forms a 4π (spheres) arrangement and of several couples of thermoluminescent dosimeters TLD 600/TLD 700. The response of the system presents a minor repeatability to 5% in several assays when being irradiated with a 239 PuBe source and a deviation of 13.8% in the Tl readings of four different spheres. The calibration factor of the system with regard to the neutrons source which was of 56.2 p Sv/nc also was calculated. These detectors will be used as passive monitors of photoneutrons in a radiotherapy room with lineal accelerator of high energy. (Author)

  8. The SIEVERT system for aircrew Dosimetry

    International Nuclear Information System (INIS)

    Clairand, I.; Fuller, N.; Bottollier-Depois, J. F.; Trompier, F.

    2009-01-01

    Flight personnel are likely to receive an effective dose of several mSv in 1 y of professional activity. In France, the order of 8 December 2003 requires airline companies to monitor the exposure of their flight personnel. This is why public authorities have made the SIEVERT system (a system for evaluating exposure to cosmic radiation in air transport), available to French airlines, to evaluate doses. The SIEVERT system has been operational for use by airlines since the start of summer 2001. So far, more than 2.5 million flights have been processed at the request of more than 30 French airlines. Furthermore, this system was opened to the public in March 2002 (http://www.sievert-system.org), so that every passenger can calculate the dose received during a flight. (authors)

  9. Practice for use of a dichromate dosimetry system

    International Nuclear Information System (INIS)

    2003-01-01

    This practice covers the preparation, testing, and procedure for using the acidic aqueous silver dichromate dosimetry system to measure absorbed dose in water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the dichromate system. It is classified as a reference standard dosimetry system (see ISO/ASTM Guide 51261). This practice describes the spectrophotometric analysis procedures for the dichromate system. This practice applies only to γ-rays, x-rays/ bremsstrahlung, and high energy electrons. This practice applies provided the following conditions are satisfied: the absorbed dose range is from 2x10 3 to 5x10 4 Gy; the absorbed dose rate does not exceed 600 Gy/pulse (12.5 pulses per second), or does not exceed an equivalent dose rate of 7.5 kGy/s from continuous sources; for radionuclide gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 8 MeV; the irradiation temperature of the dosimeter shall be above 0 deg C and should be below 80 deg C

  10. GENII (Generation II): The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-09-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs.

  11. GENII [Generation II]: The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-09-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs

  12. GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 2, Users' manual: Hanford Environmental Dosimetry Upgrade Project

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-11-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. This second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The first volume describes the theoretical considerations of the system. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 27 refs., 17 figs., 23 tabs

  13. Quality management system in the CIEMAT Radiation Dosimetry Service.

    Science.gov (United States)

    Martín, R; Navarro, T; Romero, A M; López, M A

    2011-03-01

    This paper describes the activities realised by the CIEMAT Radiation Dosimetry Service (SDR) for the implementation of a quality management system (QMS) in order to achieve compliance with the requirements of ISO/IEC 17025 and to apply for the accreditation for testing measurements of radiation dose. SDR has decided the accreditation of the service as a whole and not for each of its component laboratories. This makes it necessary to design a QMS common to all, thus ensuring alignment and compliance with standard requirements, and simplifying routine works as possible.

  14. Application of an alanine dosimetry system for industrial irradiation and radiation protection

    International Nuclear Information System (INIS)

    Gohs, U.

    1996-01-01

    This paper reports the application of alanine dosimetry in radiation processing. Continuous checks of the EPR measuring conditions as well as using high-quality alanine dosimeters and consistent technique for dose determination guarantee an accuracy of about ± 3% intermediate dose levels. The alanine dosimetry system was applied for dose mapping measurements during irradiator qualification and performance qualification of different products, routine dosimetry, and special radiation protection applications within the gamma irradiator. (author)

  15. Dosimetry of an animal irradiation system

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Nelson M.; Funari, Ana P.; Miranda, Jurandir T.; Napolitano, Celia M.; Goncalves, Josemary A.C.; Bueno, Carmen C.; Mathor, Monica B., E-mail: nelsonnininho@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Radiation therapy uses ionizing radiation for cancer treatment, but its effectiveness may be limited by the consequent appearance of radiodermatitis. This problem may present several degrees: the highest among them is radionecrosis. Therefore, a model of study for the animal irradiation system (AIS) was built, generating radionecrosis on rat backs. The AIS is comprised by: a) a shield between the {sup 60}Co irradiator metallic guide and the animal immobilizer (AI), with holes exposing the rat skin; b) a shield on the AI posterior part and (c) the AIS angle. The doses were measured with alanine pellets in seven positions (two external and five internal) and different heights, in axial planes along the AI, and irradiated with 85 Gy. The similarity in the geometry of the AIs made it possible to relate the doses of positions 1-7 with the same height among the AISs. The AISs equidistance to the source allowed simultaneous animal exposure. Minimizing the shielding and maximizing the angles among the AISs provided average doses almost identical in position 1. A small variation among the mean doses for each of the AISs enabled to replace them by the average doses of the three AISs at position 1. Shields allowed the attenuation of the uncertainties in the alanine pellet in the AI, reduction of the exposure time without compromising rat security and the rise of the dose in measurement positions 1 and 2. The maximization of the angles among the AISs reduced the shielding secondary radiation contribution. (author)

  16. Dosimetry of an animal irradiation system

    International Nuclear Information System (INIS)

    Alves, Nelson M.; Funari, Ana P.; Miranda, Jurandir T.; Napolitano, Celia M.; Goncalves, Josemary A.C.; Bueno, Carmen C.; Mathor, Monica B.

    2015-01-01

    Radiation therapy uses ionizing radiation for cancer treatment, but its effectiveness may be limited by the consequent appearance of radiodermatitis. This problem may present several degrees: the highest among them is radionecrosis. Therefore, a model of study for the animal irradiation system (AIS) was built, generating radionecrosis on rat backs. The AIS is comprised by: a) a shield between the 60 Co irradiator metallic guide and the animal immobilizer (AI), with holes exposing the rat skin; b) a shield on the AI posterior part and (c) the AIS angle. The doses were measured with alanine pellets in seven positions (two external and five internal) and different heights, in axial planes along the AI, and irradiated with 85 Gy. The similarity in the geometry of the AIs made it possible to relate the doses of positions 1-7 with the same height among the AISs. The AISs equidistance to the source allowed simultaneous animal exposure. Minimizing the shielding and maximizing the angles among the AISs provided average doses almost identical in position 1. A small variation among the mean doses for each of the AISs enabled to replace them by the average doses of the three AISs at position 1. Shields allowed the attenuation of the uncertainties in the alanine pellet in the AI, reduction of the exposure time without compromising rat security and the rise of the dose in measurement positions 1 and 2. The maximization of the angles among the AISs reduced the shielding secondary radiation contribution. (author)

  17. Dosimetry audit of radiotherapy treatment planning systems

    International Nuclear Information System (INIS)

    Bulski, Wojciech; Chelminski, Krzysztof; Rostkowska, Joanna

    2015-01-01

    In radiotherapy Treatment Planning Systems (TPS) various calculation algorithms are used. The accuracy of dose calculations has to be verified. Numerous phantom types, detectors and measurement methodologies are proposed to verify the TPS calculations with dosimetric measurements. A heterogeneous slab phantom has been designed within a Coordinated Research Project (CRP) of the IAEA. The heterogeneous phantom was developed in the frame of the IAEA CRP. The phantom consists of frame slabs made with polystyrene and exchangeable inhomogeneity slabs equivalent to bone or lung tissue. Special inserts allow to position thermoluminescent dosimeters (TLD) capsules within the polystyrene slabs below the bone or lung equivalent slabs and also within the lung equivalent material. Additionally, there are inserts that allow to position films or ionisation chamber in the phantom. Ten Polish radiotherapy centres (of 30 in total) were audited during on-site visits. Six different TPSs and five calculation algorithms were examined in the presence of inhomogeneities. Generally, most of the results from TLD were within 5 % tolerance. Differences between doses calculated by TPSs and measured with TLD did not exceed 4 % for bone and polystyrene equivalent materials. Under the lung equivalent material, on the beam axis the differences were lower than 5 %, whereas inside the lung equivalent material, off the beam axis, in some cases they were of around 7 %. The TLD results were confirmed with the ionisation chamber measurements. The comparison results of the calculations and the measurements allow to detect limitations of TPS calculation algorithms. The audits performed with the use of heterogeneous phantom and TLD seem to be an effective tool for detecting the limitations in the TPS performance or beam configuration errors at audited radiotherapy departments. (authors)

  18. Dosimetry audit of radiotherapy treatment planning systems.

    Science.gov (United States)

    Bulski, Wojciech; Chełmiński, Krzysztof; Rostkowska, Joanna

    2015-07-01

    In radiotherapy Treatment Planning Systems (TPS) various calculation algorithms are used. The accuracy of dose calculations has to be verified. Numerous phantom types, detectors and measurement methodologies are proposed to verify the TPS calculations with dosimetric measurements. A heterogeneous slab phantom has been designed within a Coordinated Research Project (CRP) of the IAEA. The heterogeneous phantom was developed in the frame of the IAEA CRP. The phantom consists of frame slabs made with polystyrene and exchangeable inhomogeneity slabs equivalent to bone or lung tissue. Special inserts allow to position thermoluminescent dosimeters (TLD) capsules within the polystyrene slabs below the bone or lung equivalent slabs and also within the lung equivalent material. Additionally, there are inserts that allow to position films or ionisation chamber in the phantom. Ten Polish radiotherapy centres (of 30 in total) were audited during on-site visits. Six different TPSs and five calculation algorithms were examined in the presence of inhomogeneities. Generally, most of the results from TLD were within 5 % tolerance. Differences between doses calculated by TPSs and measured with TLD did not exceed 4 % for bone and polystyrene equivalent materials. Under the lung equivalent material, on the beam axis the differences were lower than 5 %, whereas inside the lung equivalent material, off the beam axis, in some cases they were of around 7 %. The TLD results were confirmed with the ionisation chamber measurements. The comparison results of the calculations and the measurements allow to detect limitations of TPS calculation algorithms. The audits performed with the use of heterogeneous phantom and TLD seem to be an effective tool for detecting the limitations in the TPS performance or beam configuration errors at audited radiotherapy departments. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. The Radiotherapy Dosimetry Audit System In the UK

    International Nuclear Information System (INIS)

    Thwaites, D.I.

    1999-01-01

    Two national radiotherapy dosimetry intercomparisons have been earned out in the UK, involving all radiotherapy institutes. The first was concerned with megavoltage photon beams and looked at beam calibration and simple three-field planned distributions in a geometric phantom. The intercomparisons were carried out by an independent intercomparison physicist visiting each department in turn and making measurements with ion chambers, following a fixed protocol. The beam calibration intercomparison was earned out on every 60 C o beam and every MV x-ray beam, whilst the planned comparisons were carried out on one beam only. The plans included effects of wedges, oblique incidence and inhomogeneities. The study was unfunded and took a significant time (1988-1991) to cover the 65 or so centres. It was followed up by a national electron dosimetry intercomparison which was fended (Department of Health) and which ran from 1994-1996. This audited three electron beam energies in each centre (depth dose, beam energy, dose calibration) and also included a follow-up of the original photon beam intercomparison. In general these studies showed good consistency of dosimetry across the UK centres, with mean (measured/locally stated) doses being close to unity and standard deviations of the distributions of values being approx. 1.5 and 1% for photons, 1.8% for electrons for beam calibration and 2.5-3.5% for the planned multi-beam situations. 97-100% of measurements were within the pre-set 3% tolerance for beam calibration and around 90% of the measurements within a pre-set 5% tolerance for planned situations. The studies did highlight some areas where increased on Q A could provide benefits. In particular the photon intercomparison discovered one 60 C o unit mis calibration which led to national recommendations for the implementation of Quality Systems in radiotherapy departments

  20. Neutron dosimetry in containment of a pressurized water reactor utilizing the Panasonic UD-802 dosimetry system

    International Nuclear Information System (INIS)

    Kralick, S.C.

    1984-01-01

    The Panasonic UD-802 dosimeter was evaluated as a potential neutron dosimeter for use in containment of a PWR. The Panasonic UD-802 dosimeter, although designed as a beta and gamma dosimeter, is also sensitive to neutrons. UD-802 dosimeters were mounted on polyethylene phantoms and irradiated to known doses at selected locations in containment. The known neutron dose equivalents were determined based on remmeter dose rate measurements and stay times. The thermoluminescent response of the dosimeters and the known neutron dose equivalents were used to obtain a calibration factor at each location. The average calibration factor was 3.7 (unit of dosimeter response per mrem) and all calibration factors were within +-30% of this mean value. The dosimeter distance from the phantom was found to have minimal effect on the response but the system was directionally dependent, necessitating a correction in the calibration factor. The minimum significant dosimeter response was determined independent of any calibration factor. The minimum significant response of the UD-802 to neutrons is a function of the corresponding gamma exposure rate. It is concluded that the Panasonic UD-802 dosimeter can be used for neutron dosimetry in PWR containment

  1. Evaluation of uncertainty in dosimetry of irradiator system

    International Nuclear Information System (INIS)

    Santos, Gelson P.; Potiens, Maria P.A.; Vivolo, Vitor

    2005-01-01

    This paper describes the study of uncertainties in the estimates of dosimetry irradiator system STS 0B85 of LCI IPEN/CNEN-SP. This study is relevant for determination of best measurement capability when the laboratory performs routine calibrations of measuring radiation next the optimal measures designed to radioprotection. It is also a requirement for obtaining the accreditation of the laboratory by the INMETRO. For this dosimetry was used a reference system of the laboratory composed of a electrometer and a spherical ionization chamber of 1 liter. Measurements were made at five distances selected so to include the whole range of the optical bench tests and using three attenuators filters so as to extend the measurement capability. The magnitude used for evaluation was the rate of air kerma for 1 37C s and 6 0C o beams. Were carried out four series of measurements. It was verified the inverse square law to these series and their sets of uncertainty. Unfiltered, with one and two filters series showed good agreement with the inverse square low and the maximum uncertainty obtained was approximately 1.7%. In series with all the filters was a major deviation of the inverse square law and wide increase in uncertainty to measurements at the end of the optical bench

  2. Comparison of Different Internal Dosimetry Systems for Selected Radionuclides Important to Nuclear Power Production

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, Richard Wayne [ORNL; Eckerman, Keith F [ORNL; Manger, Ryan P [ORNL

    2013-08-01

    This report compares three different radiation dosimetry systems currently applied by various U.S. Federal agencies and dose estimates based on these three dosimetry systems for a set of radionuclides often identified in power reactor effluents. These dosimetry systems were developed and applied by the International Commission on Radiological Protection at different times over the past six decades. Two primary modes of intake of radionuclides are addressed: ingestion in drinking water and inhalation. Estimated doses to individual organs and to the whole body based on each dosimetry system are compared for each of four age groups: infant, child, teenager, and adult. Substantial differences between dosimetry systems in estimated dose per unit intake are found for some individual radionuclides, but differences in estimated dose per unit intake generally are modest for mixtures of radionuclides typically found in nuclear power plant effluents.

  3. Multisphere system neutron spectrometry applied to dosimetry for the personnel

    International Nuclear Information System (INIS)

    Allinei, P.G.

    1992-01-01

    Neutron dosimetry is a necessity that must be dealt with in order to ensure efficient monitoring of all personnel regarding radiology safety. Dosimetric variables are difficult to measure for they are dependent on complex functions evolving with the energy of neutrons, which forces us to determine their energetic distribution. We have chosen to use the multisphere system associated to an unfolding code in order to perform neutron spectrometry, our purpose being to determine these dosimetric variables. The initial stage consists in modifying a research code, the code SOHO, in order to adapt it to our needs. The resulting new version was subsequently tested and proven successful by means of computerized simulations. Afterwards, we used reference dosimetric and spectral beams to confirm the position results previously obtained. At the time of this test, the code SOHO yielded results coherent with the theoretical values, and even allowed the quantity of radiation diffused by the laboratory structures to be estimated. The final part of this study consists in applying the previously perfected technique to authentic situations. The results thus obtained are compared to those obtained by conventional methods in order to reveal the interest of neutron spectrometry used for dosimetry of the personnel

  4. Development of a three-dimensional radiation dosimetry system

    International Nuclear Information System (INIS)

    Bero, M.A.

    2001-12-01

    The direct non-destructive measurement of the radiation absorbed dose in three dimensions is considered to be technically difficult. Accurate determination of the spatial distribution of absorbed dose plays an important role in many applications particularly in medicine. In radiotherapy computer calculations are frequently used to estimate three-dimensional dose distributions in complex geometry, hence a practical dosimetry system able to provide three-dimensional (3-D) integrated measurements is highly desirable for verifying such dose predictions. Magnetic Resonance Imaging (MRI) has been used to visualise 3-D dose distributions, inside two different detector materials, namely the ferrous sulphate gel (Fricke gel) and the polymer gel system. Each of these procedures has its own drawbacks and limitations, and this research project sought to find improvements and alternatives to overcome these problems. Work on the Fricke gel led to an improved preparation procedure employing gelatin gel whose lower melting point reduces the possibility of dissolved oxygen loss. The role of each component was clarified which led to the omission of all unnecessary chemicals such as the sodium chloride and benzoic acid. Initially MRI was the only 3-D readout technique available, however simple relaxometry was used to characterise the detector quantitatively with each modification before employing an MRI scanner to obtain images. Optimisation of the active constituents saves time and effort, and minimises the cost of equipment as well as materials. A serious drawback of the Fricke gel is ion diffusion, which causes blurring of the recorded spatial distribution and much effort was given to attempts to reduce this. However it was concluded that it is possible to slow down ion diffusion but at the cost of detector sensitivity. Therefore the best way of dealing with this problem is by introducing a fast readout technique so that the dose distribution can be recorded before serious

  5. Evaluation of a novel 4D in vivo dosimetry system

    International Nuclear Information System (INIS)

    Cherpak, A.; Ding, W.; Hallil, A.; Cygler, J. E.

    2009-01-01

    A prototype of a new 4D in vivo dosimetry system capable of simultaneous real-time position monitoring and dose measurement has been developed. The radiation positioning system (RADPOS) is controlled by a computer and combines two technologies: MOSFET radiation detector coupled with an electromagnetic positioning device. Special software has been developed that allows sampling position and dose either manually or automatically in user-defined time intervals. Preliminary tests of the new device include a dosimetric evaluation of the detector in 60 Co, 6 MV, and 18 MV beams and measurements of spatial position stability and accuracy. In addition, the effect of metals and other materials on the performance of the positioning system has been investigated. Results show that the RADPOS system can measure in-air dose profiles that agree, on average, within 3%-5% of diode measurements for the energies tested. The response of the detector is isotropic within 1.6% (1 SD) with a maximum deviation of ±4.0% over 360 deg. The maximum variation in the calibration coefficient over field sizes from 6x6 to 25x25 cm 2 was 2.3% for RADPOS probe with the high sensitivity MOSFET and 4.6% for the probe with the standard sensitivity MOSFET. Of the materials tested, only aluminum, lead, and brass caused shifts in the RADPOS read position. The magnitude of the shift varied between materials and size of the material sample. Nonmagnetic stainless steel (Grade 304) caused a distortion of less than 2 mm when placed within 10 mm of the detector; therefore, it can provide a reasonable alternative to other metals if required. The results of the preliminary tests indicate that the device can be used for in vivo dosimetry in 60 Co and high-energy beams from linear accelerators.

  6. Simple optical readout for ethanol-chlorobenzene dosimetry system

    International Nuclear Information System (INIS)

    Ilijas, B.; Razem, D.

    1999-01-01

    Optical readout of the ethanol-chlorobenzene (ECB) or Dvornik dosimetry system is based on the development of the coloured secondary complex of ferric thiocyanate which has a maximum absorption at 485 nm. The applicability of a rugged, hand-held, battery powered filter colorimeter operating at 480 nm has been investigated as a reader for this purpose. This simple reader performs very well within absorbance one displaying an excellent linearity of absorbance with the concentration of Cl - ions. It is shown that by choosing the appropriate dilution factor when preparing the secondary complex solution the entire useful dose range of the dosimeter up to 2 MGy can be covered. The applicability of this reader to some other liquid chemical dosimeters is also discussed. (author)

  7. Simple optical readout for ethanol - chlorobenzene dosimetry system

    International Nuclear Information System (INIS)

    Ilijas, B.; Razem, D.

    1999-01-01

    Optical readout of the ethanol-chlorobenzene (ECB or Dvornik dosimetry system) is based on the development of coloured secondary complex of ferric thiocyanate which has a maximum absorption at 485 nm. The applicability of a rugged, hand-held, battery powered filter colorimeter operating at 480 nm has been investigated as a reader for this purpose. This simple reader performs very well within absorbance displaying an excellent linearity of absorbance with the concentration of Cl - ions. It was shown, by choosing the appropriate dilution factor when preparing the secondary complex solution, the entire useful dose range of the dosimeter up to 2 MGy can be covered. The applicability of the same reader to some other liquid chemical dosimeters is also discussed. (author)

  8. ALGORITHM VERIFICATION FOR A TLD PERSONAL DOSIMETRY SYSTEM

    International Nuclear Information System (INIS)

    SHAHEIN, A.; SOLIMAN, H.A.; MAGHRABY, A.

    2008-01-01

    Dose algorithms are used in thermoluminescence personnel dosimetry for the interpretation of the dosimeter response in terms of equivalent dose. In the present study, an automated Harshaw 6600 reader was vigorously tested prior to the use for dose calculation algorithm according to the standard established by the US Department of Energy Laboratory Accreditation Program (DOELAP). Also, manual Harshaw 4500 reader was used along with the ICRU slab phantom and the RANDO phantom in experimentally determining the photon personal doses in terms of deep dose; Hp(10), shallow dose; Hp(0.07), and eye lens dose; Hp(3). Also, a Monte Carlo simulation program (VMC-dc) free code was used to simulate RANDO phantom irradiation process. The accuracy of the automated system lies well within DOELAP tolerance limits in all test categories

  9. Iron-based radiochromic systems for UV dosimetry applications

    Science.gov (United States)

    Lee, Hannah J.; Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2018-01-01

    Phototherapy treatment using ultraviolet (UV) A and B light sources has long existed as a treatment option for various skin conditions. Quality control for phototherapy treatment recommended by the British Association of Dermatologists and British Photodermatology Group generally focused on instrumentation-based dosimetry measurements. The purpose of this study was to present an alternative, easily prepared dosimeter system for the measurement of UV dose and as a simple quality assurance technique for phototherapy treatments. Five different UVA-sensitive radiochromic dosimeter formulations were investigated and responded with a measurable and visible optical change both in solution and in gel form. Iron(III) reduction reaction formulations were found to be more sensitive to UVA compared to iron(II) oxidation formulations. One iron(III) reduction formulation was found to be especially promising due to its sensitivity to UVA dose, ease of production, and linear response up to a saturation point.

  10. Alanine-EPR dosimetry system. Why we like it?

    International Nuclear Information System (INIS)

    Stuglik, Z.

    2007-01-01

    To develop a new high-dose dosimeter we should: (1) to find material with radiation effect monotonically (if possible linearly) dependent on an absorbed dose; (2) to investigate its dosimetric characteristics (sensitivity, dose range, repeatability, accuracy, post-effects); (3) to evaluate economical parameters of new method (cost and availability of dosimetric material, cost of analytical instrument and its services); (4) to evaluate operational features of new dosimeter (sensitivity for environmental conditions, time from irradiation to the read-out); (5) to perform a calibration curve, i.e. functional dependence between radiation effect (dosimetric signal) and absorbed dose. On the base of this very stable stable ammonium radical (SAR) generated in crystalline α-alanine was established in the INCT as an alanine-EPR dosimetry system. Presented lecture describes the main features of this dosimeter

  11. Interactive and automated systems for nuclear track measurements with applications to fast neutron dosimetry

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; McNeece, J.P.; Preston, C.C.; Ruddy, F.H.

    1983-12-01

    Interactive and automatic track measuring systems have been developed primarily for fast neutron dosimetry in and around reactors. The interactive system is used for proton recoil measurements in nuclear research emulsions and the automatic systems for counting fission fragment tracks in Muscovite mica. The status of these systems, along with illustrative applications, are presented, particularly with regard to their relationship to neutron personnel dosimetry. 16 references, 12 figures

  12. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Franco E, J.G. [UAM-Xochimilco, 04960 Mexico D.F. (Mexico); Azorin N, J. [UAM-Iztapalapa, 09340 Mexico D.F. (Mexico); Diaz G, J.A.I. [CICATA, Unidad Legaria, Av. Legaria 694, 11599 mexico D.F. (Mexico); Arreola, M. [Department of Radiology, Shands Hospital at UF, PO Box 100374, Gainesville, FL 32610-0374 (United States)

    2006-07-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  13. Thermoluminescence dosimetry in quality imaging in CR mammography systems

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2006-01-01

    The aim of this work is to estimate the average glandular dose with Thermoluminescence Dosimetry (TLD) and comparison with quality imaging in CR mammography. For measuring dose, FDA and ACR use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, Full Field Digital Mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one CR mammography system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium fluoro halide. We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated x-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose that overcomes 3.0 mGy and it doesn't improve the image quality and dose to the breast will be excessive. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement. (Author)

  14. A multichannel pulse acquisition system for reactor dosimetry data

    International Nuclear Information System (INIS)

    Talpalariu, C.; Talpalariu, J.; Matei, C.

    1999-01-01

    Simultaneous measurements of many dosimetry parameters require a complex instrumentation equipment, computers and interfaces. For a very large frequency range (10 -3 to 10 6 Hz) scale and mode selection (period or frequency), a big problem in multichannel pulse measurement is that of dead time, precision and response time. The dead time for normal scale selection and for data reading or writing for every channel can be as long as the active measuring time and response time for very large frequency variation can be very long, too. To solve this problem we have designed for a simultaneous 40 channel measurement, a pulse counter sampling system and an expert operating system. Based on a 486 PC and a 10 channel Timer/Counter Card, the hardware performance of the system was improved by an expert program for early rate change detection and rate prediction. The rate value was determined from optimizing between current value, medium and long time values and shorter response time for transient signals. Significant features and advantages of the system are the following: a marked reduction in panel complexity, as many of the indicators and controls can be replaced by an interactive CRT keyboard, a reduction in the instrumentation complexity, failure detection and diagnosis, system performance monitoring, intelligent alarm handling. The system was designed from high accuracy measurements on 40 simultaneous channels fed from field radiation detectors like ionizing chambers, fission chambers and photomultipliers.. The operating system is using an auto-organizing data memory for both computing the current value and for long-term management of data, so that only the status and significant values of the input are recorded. Consequently, the algorithms of decision, search and data processing are simplified and limited to the necessary memory, although enough memory is preserved for accurate representation of the dosimetry curves. The utilization of an inferential algorithm for the

  15. Alanine-EPR dosimetry system for high industrial as well radiotherapeutic dose measurement

    International Nuclear Information System (INIS)

    Dobrovodsky, J.; Bukovjan, J.

    2005-01-01

    Slovak Institute of Metrology is developing new metrology standard for high doses, based on the alanine-EPR as a reference dosimetry system. A Bruker e-scan EPR analyser developed specifically for alanine dosimetry has improved stability of EPR measurement, especially at lower dose range. The standard e-scan system provides sensitivity below 1 Gray. After further improvement of the system and lowering of dose determination expanded uncertainty down below 1 %, its utilisation for radiotherapy field is expected (authors)

  16. US Department of Energy Laboratory Accredition Program (DOELAP) for personnel dosimetry systems

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, F.M.; Carlson, R.D.; Loesch, R.M.

    1993-12-31

    Accreditation of personnel dosimetry systems is required for laboratories that conduct personnel dosimetry for the U.S. Department of Energy (DOE). Accreditation is a two-step process which requires the participant to pass a proficiency test and an onsite assessment. The DOE Laboratory Accreditation Program (DOELAP) is a measurement quality assurance program for DOE laboratories. Currently, the DOELAP addresses only dosimetry systems used to assess the whole body dose to personnel. A pilot extremity DOELAP has been completed and routine testing is expected to begin in January 1994. It is expected that participation in the extremity program will be a regulatory requirement by January 1996.

  17. Technical Equivalency Documentation for a Newly Acquired Alpha Spectroscopy System

    International Nuclear Information System (INIS)

    Hickman, D P; Fisher, S K; Hann, P R; Hume, R

    2007-01-01

    The response of a recently acquired Canberra(trademark) Alpha Analyst 'Blue' system (Chamber Number's 173-208) used by the Hazards Control, Radiation Safety Section, WBC/Spectroscopy Team has been studied with respect to an existing Canberra system. The existing Canberra system consists of thirty Alpha Analyst dual chambers Model XXXX comprising a total of sixty detectors (Chambers Number's 101-124 and 137-172). The existing chambers were previously compared to an older system consisting of thirty-six Model 7401 alpha spectrometry chambers (Chamber Number's 1-36) Chambers 101-124 and 137-172 are DOELAP accredited. The older system was previously DOELAP accredited for the routine Alpha Spectroscopy program used in LLNL's in vitro bioassay program. The newly acquired Alpha Analyst system operates on a network with software that controls and performs analysis of the current Alpha Analyst system (Chamber Number's 101-124 and 137-172). This exact same software is used for the current system and the newly acquired system and is DOELAP accredited. This document compares results from the existing Alpha System with the newer Alpha Analyst system

  18. SSDL personel dosimetry system: migration from a client - server system into a web-based system

    International Nuclear Information System (INIS)

    Maizura Ibrahim; Rosnah Shariff; Ahmad Bazlie Abdul Kadir; John Konsoh Sangau; Mohd Amin Sharifuldin Salleh; Taiman Kadni; Noriah Mod Ali

    2007-01-01

    Personnel Dosimetry System has been used by the Secondary Standard Dosimetry Laboratory (SSDL), Nuclear Malaysia since ten years ago. The system is a computerized database system with a client-server concept. This system has been used by Film Badge Laboratory, SSDL to record details of clients, calculation of Film Badge dosage, management of radiation workers data's, generating of dosage report, retrieval of statistical reports regarding film badge usage for the purpose of reporting to monitoring bodies such as Atomic Energy Licensing Board (AELB), Ministry of Health and others. But, due to technical problems that frequently occurs, the system is going to be replaced by a newly developed web- based system called e-SSDL. This paper describe the problems that regularly occurs in the previous system, explains how the process of replacing the client-server system with a web-based system is done and the differences between the previous and current system. This paper will also present details architecture of the new system and the new process introduced in processing film badges. (Author)

  19. Quantitative evaluation of patient-specific quality assurance using online dosimetry system

    Science.gov (United States)

    Jung, Jae-Yong; Shin, Young-Ju; Sohn, Seung-Chang; Min, Jung-Whan; Kim, Yon-Lae; Kim, Dong-Su; Choe, Bo-Young; Suh, Tae-Suk

    2018-01-01

    In this study, we investigated the clinical performance of an online dosimetry system (Mobius FX system, MFX) by 1) dosimetric plan verification using gamma passing rates and dose volume metrics and 2) error-detection capability evaluation by deliberately introduced machine error. Eighteen volumetric modulated arc therapy (VMAT) plans were studied. To evaluate the clinical performance of the MFX, we used gamma analysis and dose volume histogram (DVH) analysis. In addition, to evaluate the error-detection capability, we used gamma analysis and DVH analysis utilizing three types of deliberately introduced errors (Type 1: gantry angle-independent multi-leaf collimator (MLC) error, Type 2: gantry angle-dependent MLC error, and Type 3: gantry angle error). A dosimetric verification comparison of physical dosimetry system (Delt4PT) and online dosimetry system (MFX), gamma passing rates of the two dosimetry systems showed very good agreement with treatment planning system (TPS) calculation. For the average dose difference between the TPS calculation and the MFX measurement, most of the dose metrics showed good agreement within a tolerance of 3%. For the error-detection comparison of Delta4PT and MFX, the gamma passing rates of the two dosimetry systems did not meet the 90% acceptance criterion with the magnitude of error exceeding 2 mm and 1.5 ◦, respectively, for error plans of Types 1, 2, and 3. For delivery with all error types, the average dose difference of PTV due to error magnitude showed good agreement between calculated TPS and measured MFX within 1%. Overall, the results of the online dosimetry system showed very good agreement with those of the physical dosimetry system. Our results suggest that a log file-based online dosimetry system is a very suitable verification tool for accurate and efficient clinical routines for patient-specific quality assurance (QA).

  20. Foliar application of systemic acquired resistance (SAR) inducers for ...

    African Journals Online (AJOL)

    nbuensanteai

    2013-08-14

    Aug 14, 2013 ... induced by chitosan and BTH were involved in defense mechanism, reflecting the strong direct positive effect that chitosan ... to control plant diseases based on the systemic acquired resistance ... salicylic acid (SA) as a signal molecule and is associated ... treated plants for SAR relating chemical analyses.

  1. School Reentry for Children with Acquired Central Nervous Systems Injuries

    Science.gov (United States)

    Carney, Joan; Porter, Patricia

    2009-01-01

    Onset of acquired central nervous system (CNS) injury during the normal developmental process of childhood can have impact on cognitive, behavioral, and motor function. This alteration of function often necessitates special education programming, modifications, and accommodations in the education setting for successful school reentry. Special…

  2. TL dosimetry for quality control of CR mammography imaging systems

    Science.gov (United States)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  3. SU-E-T-104: Development of 3 Dimensional Dosimetry System for Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K; Kwak, J; Cho, B; Lee, D; Ahn, S [Asan Medical Center, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to develop a new 3 dimensional dosimetry system to verify the dosimetric accuracy of Leksell Gamma Knife-Perfexion™ (LGK) (Elekta, Norcross, GA). Methods: We designed and manufactured a lightweight dosimetry instrument to be equipped with the head frame to LGK. It consists of a head phantom, a scintillator, a CCD camera and a step motor. The 10×10 cm2 sheet of Gd2O3;Tb phosphor or Gafchromic EBT3 film was located at the center of the 16 cm diameter hemispherical PMMA, the head phantom. The additional backscatter compensating material of 1 cm thick PMMA plate was placed downstream of the phosphor sheet. The backscatter plate was transparent for scintillation lights to reach the CCD camera with 1200×1200 pixels by 5.2 um pitch. With This equipment, 300 images with 0.2 mm of slice gap were acquired under three collimator setups (4mm, 8mm and 16mm), respectively. The 2D projected doses from 3D distributions were compared with the exposured film dose. Results: As all doses normalized by the maximum dose value in 16 mm setup, the relative differences between the equipment dose and film dose were 0.2% for 4mm collimator and 0.5% for 8mm. The acquisition of 300 images by the equipment took less than 3 minutes. Conclusion: The new equipment was verified to be a good substitute to radiochromic film, with which required more time and resources. Especially, the new methods was considered to provide much convenient and faster solution in the 3D dose acquisition for LGK.

  4. Dosimetry audit simulation of treatment planning system in multicenters radiotherapy

    Science.gov (United States)

    Kasmuri, S.; Pawiro, S. A.

    2017-07-01

    Treatment Planning System (TPS) is an important modality that determines radiotherapy outcome. TPS requires input data obtained through commissioning and the potentially error occurred. Error in this stage may result in the systematic error. The aim of this study to verify the TPS dosimetry to know deviation range between calculated and measurement dose. This study used CIRS phantom 002LFC representing the human thorax and simulated all external beam radiotherapy stages. The phantom was scanned using CT Scanner and planned 8 test cases that were similar to those in clinical practice situation were made, tested in four radiotherapy centers. Dose measurement using 0.6 cc ionization chamber. The results of this study showed that generally, deviation of all test cases in four centers was within agreement criteria with average deviation about -0.17±1.59 %, -1.64±1.92 %, 0.34±1.34 % and 0.13±1.81 %. The conclusion of this study was all TPS involved in this study showed good performance. The superposition algorithm showed rather poor performance than either analytic anisotropic algorithm (AAA) and convolution algorithm with average deviation about -1.64±1.92 %, -0.17±1.59 % and -0.27±1.51 % respectively.

  5. The calibration procedures in the Studsvik standardized personnel dosimetry system

    International Nuclear Information System (INIS)

    Widell, C.O.

    1978-01-01

    Every large nuclear installation in Sweden reads its own personnel TLDs. In order to supervise this decentralized reading of dose meters, the TLD readers are connected by telephone lines to a central computer for dose registration. This computer is used both for registering the personnel doses and for checking the TLD readers. This checking is performed by the use of pre-irradiated calibration dose meters which are always used when a batch of personnel dose meters are read. The pre-irradiated dose meters are either irradiated using 137 Cs to various doses up to 100mSv(10000mrem) or using a 90 Sr source in a reference dose irradiator to a dose equal to 3mSv(300mrem) from a 137 Cs source. The results from the reading of the pre-irradiated dose meters are processed by the computer and a calibration factor is calculated. The calibration factor is automatically used to calculate the doses to the personnel TLD's. However, if the calibration factor deviates by more than 10% from the previously used factor, this fact is shown to the operator - who then has to decide what calibration factor is going to be used. This calibration and supervisory procedure together with the safety interlocks in the TLD readers has resulted in a very reliable and accurate dosimetry system. (author)

  6. Arabidopsis MAP kinase 4 negatively regulates systemic acquired resistance

    DEFF Research Database (Denmark)

    Petersen, M.; Brodersen, P.; Naested, H.

    2000-01-01

    Transposon inactivation of Arabidopsis MAP kinase 4 produced the mpk4 mutant exhibiting constitutive systemic acquired resistance (SAR) including elevated salicylic acid (SA) revels, increased resistance to virulent pathogens, and constitutive pathogenesis-related gene expression shown by Northern...... of NPR1. PDF1.2 and THI2.1 gene induction by jasmonate was blocked in mpk4 expressing NahG, suggesting that MPK4 is required for jasmonic acid-responsive gene expression....

  7. Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher, Gustavo; Vandervoort, E.

    2015-01-01

    A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (Sc,p)fclindet, for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied...

  8. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  9. The NIM alanine-EPR dosimetry system: its application in NDAS programme and others

    International Nuclear Information System (INIS)

    Gao Jun-Cheng

    1999-01-01

    In 1983, National Institute of Metrology (NIM) began to study alanine-EPR dosimetry system. From 1988 on, the system has been used as a transfer standard to launch into the National Dose Assurance Service (NDAS) programme for cobalt-60 facilities in China. In this paper, the eleven years implementation of NDAS programme are presented by statistics. In 1991, under an IAEA coordinated research programme, NIM had studied to extend the range of the system to therapy level. In recent years, the NIM in cooperation with other institutes has been developing film-alanine dosimeter for electron beam dosimetry. (author)

  10. Calibration of a MOSFET detection system for 6-MV in vivo dosimetry

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Francescon, P.

    1998-01-01

    irradiation is in agreement with TLD dosimetry within 5%. Ionization chamber and MOSFET midplane dosimetry in inhomogeneous phantoms are in agreement within 2%. Conclusion: MOSFET characteristics are suitable for the in vivo dosimetry relevant to 6-MV treatments, both in normal and TBI setup. The TBI midplane dosimetry using MOSFETs is valid also in the presence of the lung, which is the most critical organ, and allows verifying that calculation of the lung attenuator thicknesses based only on the density is not correct. Our MOSFET dosimetry system can be used also to determine the surface dose by using the water-equivalent depth and extrapolation methods. This procedure depends on the field size used

  11. Irradiation process validation in the new conveyor system installed at PISI: special dosimetry

    International Nuclear Information System (INIS)

    Pantano, Barbara P.; Docters, Andrea S.

    2009-01-01

    dose-mapping will be required. Accordingly, the Operational Qualification will include dose mapping in air (i.e. without product), with the conveyor system both in a static position and moving along its path. Depending on the results obtained in the latter, dosimeter placement patterns will be defined for dose mapping on simulated product. The information acquired from the OQ will be the starting point for designing the PQ, in which the adequacy and reproducibility of the results shall be verified by means of dose mapping on real product and thus establishing the appropriate process parameters for ensuring conformity with dose requirements for these products.The aim of this special dosimetry is obtaining the process parameters such as dwell time, the product classification in different process categories, the magnitude and location of maximum and minimum dose points and their corresponding dose uniformity ratio. In conclusion, it must be remarked that this dosimetry will be more exhaustive than previous ones due to the unavailability of local referenced information for this system, and therefore, a more thorough dosimeter placing patterns will be required for the obtaining of these parameters in order to assure confidence on the future routine processing. (author)

  12. Guide for selection of dosimetry system for electron processing

    International Nuclear Information System (INIS)

    Mehta, K.

    1988-01-01

    Correct applications of radiation processing depend on accurate measurements of absorbed radiation dose. Radiation dosimetry plays several important roles in radiation processing. In particular, there are three stages for any radiation process during which dosimetry is a key to success: basic laboratory research, commissioning of the process and quality control. Radiation dosimeters may be divided into various classes depending upon their areas of applications and their relative quality: primary standard dosimeter, reference standard dosimeter, transfer standard dosimeter and routine in-house dosimeter. Several commercially available dosimeters are described under each class, and their advantages and limitations are discussed. Finally, recommendations are made as to which dosimeter is most suitable for each of the three stages of electron-beam processing. 124 refs

  13. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  14. Improvement of JCDS, a computational dosimetry system in JAEA for neutron capture therapy

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Matsumura, Akira; Yamamoto, Tetsuya; Nakagawa, Yoshinobu; Kageji, Teruyoshi

    2006-01-01

    JCDS, a computational dosimetry system for neutron capture therapy, was developed by Japan Atomic Energy Agency. The system has been sophisticated to facilitate dose planning so far. In dosimetry with JCDS for BNCT clinical trials at JRR-4, several absorbed doses and the dose distributions are determined by a voxel model consisted of 2x2x2mm 3 voxel cells. By using the detailed voxel model, accuracy of the dosimetry can be improved. Clinical trials for melanoma and head-and-neck cancer as well as brain tumor were started using hot version of JCDS in 2005. JCDS is also being of improved so as to enable a JCDS application to dosimetry by PHITS as well as dosimetry by MCNP. By using PHITS, total doses of a patient by a combined modality therapy, for example a combination of BNCT and proton therapy, can be estimated consistently. Moreover, PET images can be adopted in combination with CT and MRI images as a farsighted approach. JCDS became able to identify target regions by using the PET values. (author)

  15. [Acquiring Science English: A Plan and System Are Needed].

    Science.gov (United States)

    Foong, Foo Wah

    2018-01-01

     Literary English is different from science English (SE) and pharmaceutical science English (PSE). Therefore, a totally new approach was adopted for students to learn PSE at Kyoto Pharmaceutical University (KPU). In 2012, a 4-year program for teaching PSE was proposed, and a stepwise-stepup tertiary science English education (SSTSEE) system was introduced at KPU. The system provides a novel form of PSE teaching that stretches from year 1 to 4, where the PSE level progresses to higher levels of learning with each passing academic year. With the launch of the SSTSEE system, relevant science-educated staff were provided with training and were also requested to study the syllabi of the respective academic years to write textbooks with the appropriate PSE content for their respective levels. From 2012 to 2015, textbooks and curricula for 4 year academic levels were developed and published to meet the needs for PSE learning at each academic level. Based on results of the SSTSEE system, year 1 students acquired the SE basics, and year 2 students applied the SE basics acquired. In years 3 and 4, students further pursued and developed their PSE ability. Additionally, students participated actively in developing skills in the reading, listening, writing, and speaking of SE/PSE. Active-plus-deep learning prompted students in developing those skills using illustrations, posters, and power-point slideshow presentations. By year 4, average achievers had established an independent level of competency in reading, listening, speaking, and writing PSE. Moreover, the SSTSEE system accommodated students timely in developing communication skills for practical fieldwork (clerkships) at pharmacies/hospitals in year 5 and for their future endeavors.

  16. The SISERI system: an information system for occupational dosimetry registration

    International Nuclear Information System (INIS)

    Scanff, P.; Crescini, D.; Vial, E.

    2013-01-01

    The SISERI information system was developed and brought into use in order to meet a workplace health objective aimed at reducing and controlling exposure of workers to ionising radiation in France. Dosimetric monitoring of workers in France annually concerns 280.000 people who are exposed to ionising radiation as part of their work. This system centralizes, verifies and preserves all dosimetric data relating to each worker in accordance with the confidentiality required by the personal nature of this information. The SISERI data are made available to occupational doctors and experts in radiation protection to assist them in monitoring exposure of workers. The data are also intended for statistical processing with the aim of optimizing radiation protection for workers. They may also be used for epidemiological studies. The system has been gradually developed since it came into service in February 2005 and is now operating normally so that it is possible to guarantee that all doses received by each worker, anywhere on French territory, are recorded. If this system can be extended outside French borders it will be easier to monitor workers who have to travel to different European countries. The slides of the presentation have been added at the end of the paper. (authors)

  17. Management system of personnel dosimetry based on ISO 9001:2008 for medical diagnostic

    International Nuclear Information System (INIS)

    Queiroz, Carlos E.B.; Gerber Junior, Walmoli; Jahn, Tiago R.; Hahn, Tiago T.; Fontana, Thiago S.; Bolzan, Vagner

    2013-01-01

    MDose is a computer management system of personal dosimetry in diagnostic radiology services physician based on ISO 9001:9008 management system. According to Brazilian law all service radiology should implement a control of personal dosimetry in addition to radiation doses greater than 1.5 mSv/year service should do research of high dose, which is to identify the causes the resulting dose increase professional. This work is based on the use of the PDCA cycle in a JAVA software developed as a management method in the analysis of high doses in order to promote systematic and continuous improvement within the organization of radiological protection of workers

  18. Year 2000 compliance concerns with the ISA Thermoluminescent Dosimetry Data Processing (TL-DP) software system

    Energy Technology Data Exchange (ETDEWEB)

    Saviz, K.

    1998-05-26

    The year 2000 is rapidly approaching, and there is a good chance that computer systems that utilize two digit year dates will experience problems in retrieval of date information. The ISA Thermoluminescent Dosimetry Data Processing (TL-DP) software and computer system has been reviewed for Year 2000 compliance issues.

  19. Year 2000 compliance concerns with the ISA Thermoluminescent Dosimetry Data Processing (TL-DP) software system

    International Nuclear Information System (INIS)

    Saviz, K.

    1998-01-01

    The year 2000 is rapidly approaching, and there is a good chance that computer systems that utilize two digit year dates will experience problems in retrieval of date information. The ISA Thermoluminescent Dosimetry Data Processing (TL-DP) software and computer system has been reviewed for Year 2000 compliance issues

  20. Experiences and performance of the Harshaw dosimetry system at two major processing centres

    International Nuclear Information System (INIS)

    Tawil, R.A.; Olhalber, T.; Rathbone, B.

    1996-01-01

    The installations, operating practice, dose algorithms and results and maintenance experience at two major dosimetry processing centres are described. System selection considerations and a comprehensive quality programme are described in the light of the publication of testing requirements by various dosimetry regulatory organisations. Reported information from Siemens Dosimetry Services comprises their selection of dosemeters and processing equipment including service history, a description of their dose computation algorithm, and detailed results of their testing against DOELAP standards. Battelle Pacific Northwest Laboratories (PNL) provides a description of their dosemeters and equipment with service history; in addition, a discussion of their new neural network approach to a dose computation algorithm and test results from that algorithm are presented. (Author)

  1. Congenital and acquired mitochondrial disorders of the central nervous system

    Directory of Open Access Journals (Sweden)

    V. V. Nikitina

    2014-01-01

    Full Text Available Clinical presentations of disorders of the nervous system manifest in young and middle-aged patients with congenital and acquired mitochondrial dysfunctions and cognitive disorders manifest in patients with mitochondrial diseases more often. Nowadays the effective methods of initial diagnosing of these conditions are neurological and neuropsychological examination of patients, using of biochemical markers of mitochondrial diseases: the indices of lactate, total homocysteine in plasma and liquor. Neuro-visual study (Magnetic resonance imaging of the brain, MR spectroscopy, tractography, diffusion-weighted magnetic resonance imaging of the brain, mitochondrial DNA typing is actually used for the differential diagnosing of mitochondrial diseases with other disorders that are accompanied by demyelinating disorders.

  2. ASSESSMENT OF UNCERTAINTY IN THE RADIATION DOSES FOR THE TECHA RIVER DOSIMETRY SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Napier, Bruce A.; Degteva, M. O.; Anspaugh, L. R.; Shagina, N. B.

    2009-10-23

    In order to provide more accurate and precise estimates of individual dose (and thus more precise estimates of radiation risk) for the members of the ETRC, a new dosimetric calculation system, the Techa River Dosimetry System-2009 (TRDS-2009) has been prepared. The deterministic version of the improved dosimetry system TRDS-2009D was basically completed in April 2009. Recent developments in evaluation of dose-response models in light of uncertain dose have highlighted the importance of different types of uncertainties in the development of individual dose estimates. These include uncertain parameters that may be either shared or unshared within the dosimetric cohort, and also the nature of the type of uncertainty as aleatory or epistemic and either classical or Berkson. This report identifies the nature of the various input parameters and calculational methods incorporated in the Techa River Dosimetry System (based on the TRDS-2009D implementation), with the intention of preparing a stochastic version to estimate the uncertainties in the dose estimates. This report reviews the equations, databases, and input parameters, and then identifies the author’s interpretations of their general nature. It presents the approach selected so that the stochastic, Monte-Carlo, implementation of the dosimetry System - TRDS-2009MC - will provide useful information regarding the uncertainties of the doses.

  3. Guidelines for the Calibration of Routine Dosimetry Systems for use in Radiation Processing

    DEFF Research Database (Denmark)

    Sharpe, Peter; Miller, Arne

    A set of guidelines has been developed to assist in the calibration of routine dosimetry systems for use in industrial radiation processing plants. Topics covered include the calibration of equipment, the performance of calibration irradiations and the derivation of mathematical functions...

  4. GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 1, Conceptual representation

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-12-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes code logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 72 refs., 15 figs., 34 tabs

  5. GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 1, Conceptual representation

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-12-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes code logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 72 refs., 15 figs., 34 tabs.

  6. Alanine/ESR dosimetry system for routine use in radiation processing

    International Nuclear Information System (INIS)

    Kojima, T.; Haruyama, Y.; Tachibana, H.; Tanaka, R.; Okamoto, J.; Hara, H.; Kashiwazaki, S.

    1993-01-01

    A new alanine-polystyrene(PS) dosimeter prepared with simplified molding procedure and an automatic desk-top dose-reader of alanine dosimeter were developed for the purpose of routine use. Combination of these two allows us to apply a reliable alanine/ESR dosimetry system to routine dosimetric process control in industrial gamma radiation processing. (Author)

  7. TV-acquired optical diagnostics systems on ATA

    International Nuclear Information System (INIS)

    Kalibjian, R.; Chong, Y.P.; Cornish, J.P.; Jackson, C.H.; Fessenden, T.J.

    1984-06-01

    The purpose of this paper is to report on optical system developments on the ATA and their applications to ATA beam characterization. Television (TV)-acquired optical diagnostics data provide spatial and temporal properties of the ATA beam that complements recorded information from other types of sensors, such as, beam-wall current monitors, x-ray probes, and rf probes. The ATA beam operates: (1) in the normal mode at 50-MeV, 10-kA at a 1-Hz rate; and (2) in the 1-KHz burst mode (for 10-pulses) at a 0.5 Hz rate. The beam has a 70-ns pulse width in vacuum propagation; however, beam-head erosion will occur in atmospheric propagation, thus limiting the pulse width to less than 50-ns. Various optical systems are used for ATA diagnostics. Optical-imaging provides a convenient measurement in a single pulse of the 2-dimensional profile of the beam intensity. It can also provide multiple 2-D framing in a single pulse. In some studies it may be desirable to study optical events with temporal resolution less than 100-ps with 1-dimensional streak cameras. Spatially integrated data from phototube cameras can also be used for background measurement applications as well as for single pixel monitoring. The optical line-of-sight (LOS) configurations have been made versatile to accommodate a large number of options for the various optical systems

  8. The U.S. Department of Energy Laboratory Accreditation Program for testing the performance of extremity dosimetry systems: a summary of the program status

    International Nuclear Information System (INIS)

    Cummings, F.M.; Carlson, R.D.; Gesell, T.F.; Loesch, R.M.

    1992-01-01

    In 1986, The U.S. Department of Energy (DOE) implemented a program to test the performance of its personnel whole-body dosimetry systems. This program was the DOE Laboratory Accreditation Program (DOELAP). The program parallels the performance testing program specified in the American National Standard for Dosimetry - Personnel Dosimetry Performance -Criteria for Testing (ANSI N13.11-1983), but also addresses the additional dosimetry needs of DOE facilities. As an extension of the whole-body performance testing program, the DOE is now developing a program to test the performance of personnel extremity dosimetry systems. The draft DOE standard for testing extremity dosimetry systems is much less complex than the whole-body dosimetry standard and reflects the limitations imposed on extremity dosimetry by dosimeter design and irradiation geometry. A pilot performance test session has been conducted to evaluate the proposed performance-testing standard. (author)

  9. Introduction of a deformable x-ray CT polymer gel dosimetry system

    Science.gov (United States)

    Maynard, E.; Heath, E.; Hilts, M.; Jirasek, A.

    2018-04-01

    This study introduces the first 3D deformable dosimetry system based on x-ray computed tomography (CT) polymer gel dosimetry and establishes the setup reproducibility, deformation characteristics and dose response of the system. A N-isopropylacrylamide (NIPAM)-based gel formulation optimized for x-ray CT gel dosimetry was used, with a latex balloon serving as the deformable container and low-density polyethylene and polyvinyl alcohol providing additional oxygen barrier. Deformable gels were irradiated with a 6 MV calibration pattern to determine dosimetric response and a dosimetrically uniform plan to determine the spatial uniformity of the response. Wax beads were added to each gel as fiducial markers to track the deformation and setup of the gel dosimeters. From positions of the beads on CT images the setup reproducibility and the limits and reproducibility of gel deformation were determined. Comparison of gel measurements with Monte Carlo dose calculations found excellent dosimetric accuracy, comparable to that of an established non-deformable dosimetry system, with a mean dose discrepancy of 1.5% in the low-dose gradient region and a gamma pass rate of 97.9% using a 3%/3 mm criterion. The deformable dosimeter also showed good overall spatial dose uniformity throughout the dosimeter with some discrepancies within 20 mm of the edge of the container. Tracking of the beads within the dosimeter found that sub-millimetre setup accuracy is achievable with this system. The dosimeter was able to deform and relax when externally compressed by up to 30 mm without sustaining any permanent damage. Internal deformations in 3D produced average marker movements of up to 12 mm along the direction of compression. These deformations were also shown to be reproducible over 100 consecutive deformations. This work has established several important characteristics of a new deformable dosimetry system which shows promise for future clinical applications, including the

  10. Monoterpenes Support Systemic Acquired Resistance within and between Plants.

    Science.gov (United States)

    Riedlmeier, Marlies; Ghirardo, Andrea; Wenig, Marion; Knappe, Claudia; Koch, Kerstin; Georgii, Elisabeth; Dey, Sanjukta; Parker, Jane E; Schnitzler, Jörg-Peter; Vlot, A Corina

    2017-06-01

    This study investigates the role of volatile organic compounds in systemic acquired resistance (SAR), a salicylic acid (SA)-associated, broad-spectrum immune response in systemic, healthy tissues of locally infected plants. Gas chromatography coupled to mass spectrometry analyses of SAR-related emissions of wild-type and non-SAR-signal-producing mutant plants associated SAR with monoterpene emissions. Headspace exposure of Arabidopsis thaliana to a mixture of the bicyclic monoterpenes α-pinene and β-pinene induced defense, accumulation of reactive oxygen species, and expression of SA- and SAR-related genes, including the SAR regulatory AZELAIC ACID INDUCED1 ( AZI1 ) gene and three of its paralogs. Pinene-induced resistance was dependent on SA biosynthesis and signaling and on AZI1 Arabidopsis geranylgeranyl reductase1 mutants with reduced monoterpene biosynthesis were SAR-defective but mounted normal local resistance and methyl salicylate-induced defense responses, suggesting that monoterpenes act in parallel with SA The volatile emissions from SAR signal-emitting plants induced defense in neighboring plants, and this was associated with the presence of α-pinene, β-pinene, and camphene in the emissions of the "sender" plants. Our data suggest that monoterpenes, particularly pinenes, promote SAR, acting through ROS and AZI1 , and likely function as infochemicals in plant-to-plant signaling, thus allowing defense signal propagation between neighboring plants. © 2017 American Society of Plant Biologists. All rights reserved.

  11. A novel system to tackle hospital acquired pressure ulcers.

    Science.gov (United States)

    Renganathan, B S; Preejith, S P; Nagaiyan, Sridhar; Joseph, Jayaraj; Sivaprakasam, Mohanasankar

    2016-08-01

    Hospital acquired pressure ulcers (HAPUs) is a major problem that affects around one in twenty patients who are admitted in hospital with sudden illness. These ulcers often occur when patients have limited mobility and cannot change positions in bed on their own. Traditionally, the occurrence of HAPUs has been minimized by turning the patient every 2 hours to alternating lateral and supine positions, and by using pressure redistributing mattresses. In many healthcare facilities, such a patient repositioning schedule is not always maintained owing to low caregiver compliance to turning protocols. Difficulty in monitoring patient position continuously, lack of turn reminders/alerts and suboptimal caregiver staffing ratio increases the occurrence of HAPUs. A novel method to address the need for improved pressure ulcer prevention is presented. The proposed method consists of a wearable device which continuously monitors the patient's position and communicates wirelessly with a tablet which enables alerts to be sent to the caregiver when a patient turn is due in accordance with the protocol adopted by the hospital. The patient's position is continuously monitored and the turning procedure carried out is logged and updated on the hospital's cloud system, thereby enabling centralized monitoring. Under a controlled setting, system was able to continuously monitor patient's position and can accurately detect standard patient positions.

  12. Small Field Dosimetry Using Optical-Fiber Radioluminescence and Radpos Dosimetry Systems

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Vandervoort, E.

    2012-01-01

    as an electromagnetic positioning sensor and a μMOSFET for dose measurement. Materials and Methods: Relative output factors (ROF) for Cyberknife cones ranging from 5 to 60 mm were measured using RL and RADPOS systems. For comparison, measurements were also carried out using a mobileMOSFET system (BEST Medical Canada......) and GafChromic films EBT1 and EBT2 (ISP, USA). The MOSFET detectors in both mobileMOSFET and RADPOS systems were standard sensitivity μMOSFETs (TN502RDM), with a standard bias applied during irradiation. The measurements were performed in a solid water phantom at the depth of 1.5 cm and SSD = 78.5 cm....... Detector readings for each cone were normalized to those for 60 mm cone. For MOSFET detectors in both mobileMOSFET and RADPOS systems, the corrections proposed by Francescon et al. (J Appl Clin Med Phys, 10 (1), 14752, 2009) were applied. Since FWHM of our Cyberknife source is 2.4mm, the μMOSFET...

  13. Space dosimetry measurements in the stratosphere using different active and passive dosimetry systems

    International Nuclear Information System (INIS)

    Zabori, Balazs; Hirn, Attila; Deme, Sandor; Apathy, Istvan; Csoke, Antal; Pazmandi, Tamas; Szanto, Peter

    2016-01-01

    Several measurements have been performed on the cosmic radiation field from the surface of the Earth up to the maximum altitudes of research aeroplanes. However, there is only limited information about that between 15 and 30 km altitudes. In order to study the radiation environment in the stratosphere, an experiment was built by students from Hungarian universities that flew on board the BEXUS (Balloon Experiments for University Students) stratospheric balloon in Northern Sweden, from the ESRANGE Space Center. The main technical goals of the experiment were to test at the first time the TRITEL 3D silicon detector telescope system in close to space conditions and to develop a balloon technology platform for advanced cosmic radiation and dosimetric measurements. The main scientific goals were to give an assessment of the cosmic radiation field at the altitude of the BEXUS balloons, to use the TRITEL system to determine dosimetric and radiation quantities during the balloon flight and to intercompare the TRITEL and Pille results to provide a correction factor for the Pille measurements. To fulfil the scientific and technological objectives, several different dosimeter systems were included in the experiment: an advanced version of the TRITEL silicon detector telescope, Geiger-Mueller (GM) counters and Pille thermoluminescent dosimeters. The float altitude of the BEXUS balloon was ∼28.6 km; the total flight time was ∼4 h. Measurement data from the active instruments were received in real time by the ground team during the mission. There were no failures in the operation of the system; everything worked as expected. This article presents the scientific goals and results in detail. From the TRITEL measurements, the linear energy transfer spectra, the average quality factor of the cosmic radiation as well as the absorbed dose and the dose equivalent were determined. Estimations for the uncertainty in the TRITEL measurements were given. The deposited energy spectra

  14. Design and realization of a dosimetry and radiology system for nuclear power plants

    International Nuclear Information System (INIS)

    Capelle, M.

    Computer-assisted acquisition of radiation exposure data and related tasks was established at an early stage at Biblis nuclear power plant of RWE. Due to the positive experience with this system a similar, more sophisticated system has been developed for the nuclear power plants at Grundremmingen, Muelheim-Kaerlich and Kalkar. This system, DORA (Dosimetry and radiological monitoring) is described in the article. (RW) [de

  15. Acquire: an open-source comprehensive cancer biobanking system.

    Science.gov (United States)

    Dowst, Heidi; Pew, Benjamin; Watkins, Chris; McOwiti, Apollo; Barney, Jonathan; Qu, Shijing; Becnel, Lauren B

    2015-05-15

    The probability of effective treatment of cancer with a targeted therapeutic can be improved for patients with defined genotypes containing actionable mutations. To this end, many human cancer biobanks are integrating more tightly with genomic sequencing facilities and with those creating and maintaining patient-derived xenografts (PDX) and cell lines to provide renewable resources for translational research. To support the complex data management needs and workflows of several such biobanks, we developed Acquire. It is a robust, secure, web-based, database-backed open-source system that supports all major needs of a modern cancer biobank. Its modules allow for i) up-to-the-minute 'scoreboard' and graphical reporting of collections; ii) end user roles and permissions; iii) specimen inventory through caTissue Suite; iv) shipping forms for distribution of specimens to pathology, genomic analysis and PDX/cell line creation facilities; v) robust ad hoc querying; vi) molecular and cellular quality control metrics to track specimens' progress and quality; vii) public researcher request; viii) resource allocation committee distribution request review and oversight and ix) linkage to available derivatives of specimen. © The Author 2015. Published by Oxford University Press.

  16. Acquired Von Willebrand’s Syndrome in Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Sara Taveras Alam

    2014-01-01

    Full Text Available Acquired von Willebrand syndrome (AVWS is an uncommon, underdiagnosed, and heterogeneous disease which is increasingly recognized as a cause of bleeding diatheses. Systemic lupus erythematosus (SLE is an infrequent cause of AVWS. Herein, we report a case of AVWS diagnosed during the initial presentation of SLE in a previously healthy young man with no family history of bleeding diathesis who presented with worsening epistaxis, gastrointestinal bleeding, and anasarca. He was found to have severe anemia and prolonged activated partial thromboplastin time (aPTT with severely decreased levels of von Willebrand factor (VWF measurements in addition to markedly decreased factor VIII levels. Further evaluation revealed nephrotic syndrome and interstitial lung disease due to SLE. He initially received combination therapy with intravenous immunoglobulin (IVIG and von Willebrand factor/factor VIII concentrates without significant improvement. Treatment with steroids, cyclophosphamide, and rituximab was followed by clinical improvement evidenced by cessation of bleeding. The short follow-up did not allow us to definitely prove the therapeutic effect of immunosuppressive treatment on AVWS in SLE patients. This case adds to the literature supporting the relationship between AVWS and SLE and highlights the importance of combination therapy in the treatment of severe AVWS as well as the role of IVIG, cyclophosphamide, and rituximab in AVWS associated with SLE.

  17. Characterizing a pulse-resolved dosimetry system for complex radiotherapy beams using organic scintillators

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Ottosson, Rickard; Lindvold, Lars René

    2011-01-01

    A fast-readout dosimetry system based on fibre-coupled organic scintillators has been developed for the purpose of conducting point measurements of absorbed dose in radiotherapy beams involving high spatial and temporal dose gradients. The system measures the dose for each linac radiation pulse w...... and quality assurance of complex radiotherapy treatments.......A fast-readout dosimetry system based on fibre-coupled organic scintillators has been developed for the purpose of conducting point measurements of absorbed dose in radiotherapy beams involving high spatial and temporal dose gradients. The system measures the dose for each linac radiation pulse....... No significant differences between measurements and simulations were observed. The temporal resolution of the system was demonstrated by measuring dose per pulse, beam start-up transients and the quality factor for 6 MV. The precision of dose per pulse measurements was within 2.7% (1 SD) for a 10 cm × 10 cm...

  18. Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.

    Science.gov (United States)

    Médioni, R; Asselineau, B; Verrey, B; Trompier, F; Itié, C; Texier, C; Muller, H; Pelcot, G; Clairand, I; Jacquet, X; Pochat, J L

    2004-01-01

    In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue.

  19. Design, comparison, and testing of a new user-friendly extremity dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Stadtmann, H.; Schmitzer, C.; Michler, E. [Austrian Research Centre, Seibersdorf (Austria); Fellinger, J.; Velbeck, K.J.; Rotunda, J.E. [BICRON RMP, Solon (United States)

    2000-05-01

    A new extremity TLD system has been developed and tested that provides for user convenience and automated processing while meeting various accreditation requirements. The design is a result of successful collaboration among organisational entities in different countries and included research centres, users, and the manufacturer. The primary consideration was to meet the needs of the medical market, without losing sight of the needs of research laboratories and power plants. This dosimetry system design provides various detector designs based on the need to measure photons or betas. Beyond the fundamental need for accurate dosimetry, the system meets the customers need for a versatile and comfortable ring and provides for both hot and cold sterilisation. The system represents a unique integration of components comprising the finger ring, dosimeter and dosimeter identification system, and TLD Instruments. The dosimeter identification system in the TLD Reader incorporates a CCD Camera and Machine Vision Technology to interpret the circular bar codes used to quickly and accurately identifies each individual dosimeter. Portability of this dosimetry system has been realised with the adaptation into multiple TLD Instruments. (author)

  20. Design, comparison, and testing of a new user-friendly extremity dosimetry system

    International Nuclear Information System (INIS)

    Stadtmann, H.; Schmitzer, C.; Michler, E.; Fellinger, J.; Velbeck, K.J.; Rotunda, J.E.

    2000-01-01

    A new extremity TLD system has been developed and tested that provides for user convenience and automated processing while meeting various accreditation requirements. The design is a result of successful collaboration among organisational entities in different countries and included research centres, users, and the manufacturer. The primary consideration was to meet the needs of the medical market, without losing sight of the needs of research laboratories and power plants. This dosimetry system design provides various detector designs based on the need to measure photons or betas. Beyond the fundamental need for accurate dosimetry, the system meets the customers need for a versatile and comfortable ring and provides for both hot and cold sterilisation. The system represents a unique integration of components comprising the finger ring, dosimeter and dosimeter identification system, and TLD Instruments. The dosimeter identification system in the TLD Reader incorporates a CCD Camera and Machine Vision Technology to interpret the circular bar codes used to quickly and accurately identifies each individual dosimeter. Portability of this dosimetry system has been realised with the adaptation into multiple TLD Instruments. (author)

  1. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  2. Alanine-EPR as a transfer standard dosimetry system for low energy X radiation

    International Nuclear Information System (INIS)

    Khoury, H.J.; Silva, E.J. da; Mehta, K.; Barros, V.S. de; Asfora, V.K.; Guzzo, P.L.; Parker, A.G.

    2015-01-01

    The purpose of this paper is to evaluate the use of alanine-EPR as a transfer standard dosimetry system for low energy X radiation, such as that in RS-2400, which operates in the range from 25 to 150 kV and 2 to 45 mA. Two types of alanine dosimeters were investigated. One is a commercial alanine pellets from Aérial-Centre de Ressources Technologiques, France and one was prepared in our laboratory (LMRI-DEN/UFPE). The EPR spectra of the irradiated dosimeters were recorded in the Nuclear Energy Department of UFPE, using a Bruker EMX10 EPR spectrometer operating in the X-band. The alanine-EPR dosimetry system was calibrated in the range of 20–220 Gy in this X-ray field, against an ionization chamber calibrated at the relevant X-ray energy with traceability to PTB. The results showed that both alanine dosimeters presented a linear dose response the same sensitivity, when the EPR signal was normalized to alanine mass. The total uncertainty in the measured dose was estimated to be about 3%. The results indicate that it is possible to use the alanine-EPR dosimetry system for validation of a low-energy X ray irradiator, such as RS-2400.

  3. Microsoft Acquired Nokia in Unipolar Operating System Market

    Directory of Open Access Journals (Sweden)

    Netra Pal Singh

    2014-09-01

    Full Text Available The recent big tickets include Microsoft acquiring part of Nokia for US$ 7.2 billion, Verizon buy 45% stake in Vodafone for US$130 billion, Google acquiring Motorola for 12.5 billion. These buyouts are analyzed and commented by experts of the industry. This research paper attempted to collate their view in the context of Microsoft and Nokia deal on six parameters. These parameters are (i reasons for the downfall of the Nokia market share, (ii general comments of the experts, (iii similarities / dissimilarities of past and business models of the smartphone business, (iv reasons for Microsoft to buy out Nokia, (vi impact of buyout on Microsoft, Nokia, consumers and markets.

  4. Automatic neutron dosimetry system based on fluorescent nuclear track detector technology

    International Nuclear Information System (INIS)

    Akselrod, M.S.; Fomenko, V.V.; Bartz, J.A.; Haslett, T.L.

    2014-01-01

    For the first time, the authors are describing an automatic fluorescent nuclear track detector (FNTD) reader for neutron dosimetry. FNTD is a luminescent integrating type of detector made of aluminium oxide crystals that does not require electronics or batteries during irradiation. Non-destructive optical readout of the detector is performed using a confocal laser scanning fluorescence imaging with near-diffraction limited resolution. The fully automatic table-top reader allows one to load up to 216 detectors on a tray, read their engraved IDs using a CCD camera and optical character recognition, scan and process simultaneously two types of images in fluorescent and reflected laser light contrast to eliminate false-positive tracks related to surface and volume crystal imperfections. The FNTD dosimetry system allows one to measure neutron doses from 0.1 mSv to 20 Sv and covers neutron energies from thermal to 20 MeV. The reader is characterised by a robust, compact optical design, fast data processing electronics and user-friendly software. The first table-top automatic FNTD neutron dosimetry system was successfully tested for LLD, linearity and ability to measure neutrons in mixed neutron-photon fields satisfying US and ISO standards. This new neutron dosimetry system provides advantages over other technologies including environmental stability of the detector material, wide range of detectable neutron energies and doses, detector re-readability and re-usability and all-optical readout. A new adaptive image processing algorithm reliably removes false-positive tracks associated with surface and bulk crystal imperfections. (authors)

  5. Quality assurance manual for the Department of Energy laboratory accreditation program for personnel dosimetry systems

    International Nuclear Information System (INIS)

    1987-02-01

    The overall purpose of this document is to establish a uniform approach to quality assurance. This will ensure that uniform, high-quality personnel dosimetry practices are followed by the participating testing laboratories. The document presents guidelines for calibrating and maintaining measurement and test equipment (M and TE), calibrating radiation fields, and subsequently irradiating and handling personnel dosimeters in laboratories involved in the DOE dosimetry systems testing program. Radiation energies for which the test procedures apply are photons with approximately 15 keV to 2 MeV, beta particles above 0.3 MeV, neutrons with approximately 1 keV to 2 MeV. 12 refs., 4 tabs

  6. US Department of Energy Laboratory Accreditation Program for personnel dosimetry systems (DOELAP)

    International Nuclear Information System (INIS)

    Carlson, R.D.; Gesell, T.F.; Kalbeitzer, F.L.; Roberson, P.L.; Jones, K.L.; MacDonald, J.C.; Vallario, E.J.; Pacific Northwest Lab., Richland, WA; USDOE Assistant Secretary for Nuclear Energy, Washington, DC

    1988-01-01

    The US Department of Energy (DOE) Office of Nuclear Safety has developed and initiated the DOE Laboratory Accreditation Program (DOELAP) for personnel dosimetry systems to assure and improve the quality of personnel dosimetry at DOE and DOE contractor facilities. It consists of a performance evaluation program that measures current performance and an applied research program that evaluates and recommends additional or improved test and performance criteria. It also provides guidance to DOE, identifying areas where technological improvements are needed. The two performance evaluation elements in the accreditation process are performance testing and onsite assessment by technical experts. Performance testing evaluates the participant's ability to accurately and reproducibly measure dose equivalent. Tests are conducted in accident level categories for low- and high-energy photons as well as protection level categories for low- and high-energy photons, beta particles, neutrons and mixtures of these

  7. Technical guidelines for personnel dosimetry calibrations

    International Nuclear Information System (INIS)

    Roberson, P.L.; Fox, R.A.; Hadley, R.T.; Holbrook, K.L.; Hooker, C.D.; McDonald, J.C.

    1983-01-01

    A base of technical information has been acquire and used to evaluate the calibration, design, and performance of selected personnel systems in use at Department of Energy (DOE) facilites. A technical document was prepared to guide DOE and DOE contractors in selecting and evaluating personnel dosimetry systems and calibration. A parallel effort was initiated to intercompare the adiological calibrations standards used to calibrate DOE personnel dosimeters

  8. An investigation of the photon energy dependence of the EPR alanine dosimetry system

    International Nuclear Information System (INIS)

    Bergstrand, Eva Stabell; Shortt, Ken R; Ross, Carl K; Hole, Eli Olaug

    2003-01-01

    The electron paramagnetic resonance (EPR) alanine dosimetry system is based on EPR measurements of radicals formed in alanine by ionizing radiation. The system has been studied to determine its energy dependence for photons in the 10-30 MV region relative to those of 60 Co and to find out if the system would be suitable for dosimetry comparisons. The irradiations were carried out at the National Research Council, Ottawa, Canada and the doses ranged from 8 to 54 Gy. The EPR measurements were performed at the University of Oslo, Norway. The ratio of the slope of the alanine reading versus dose-to-water curve for a certain linac photon beam quality and the corresponding slope for a reference 60 Co γ-radiation gives an experimental measure of the relative dose-to-water response of the EPR alanine dosimetry system. For calculating the linear regression coefficients of these alanine reading versus dose curves, the method of weighted least squares was used. This method is assumed to produce more accurate regression coefficients when applied to EPR dosimetry than the common method of standard least squares. The overall uncertainty on the ratio of slopes was between 0.5 and 0.6% for all three linac energies. The relative response for all the linac beams compared to cobalt was less than unity: by about 0.5% for the 20 and 30 MV points but by more than 1% for the 10 MV point. The given standard uncertainties negate concluding that there is any significant internal variation in the measured response as a function of beam quality between the three linac energies. Thus, we calculated the average dose response for all three energies and found that the alanine response is 0.8% (±0.5%) lower for high energy x-rays than for 60 Co γ-rays. This result indicates a small energy dependence in the alanine response for the high-energy photons relative to 60 Co which may be significant. This result is specific to our dosimetry system (alanine with 20% polyethylene binder pressed into a

  9. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  10. The task of official personal monitoring in Germany using electronic dosimetry systems

    International Nuclear Information System (INIS)

    Huebner, Stephan; Wahl, Wolfgang; Busch, Frank; Martini, Ekkehard

    2008-01-01

    Full text: Since the establishment of the first German personal monitoring services as competent measuring bodies in the year 1952, official personal dosimetry is carried out using passive dosimeters such as film batches, RPL- and TL-dosimeters solely. On the other hand, electronic dosimeters are in use in some big institutions like Nuclear Power Plants, hospitals or industrial units for operational purposes. In most cases, these dosimeters are regulated by competent authorities. For more than 20 years electronic dosimeters proved their worth of being appropriate personal dosimeters. Since 2001 concepts to implement electronic personal dosimeters into the official individual monitoring of occupational exposed workers were developed in different research projects. The EU market of personal dosimetry changes to an open and competitive one, the number of outside workers, especially during the outages of Nuclear Power Plants increases, the landscape of customers is getting more and more heterogeneous. Being able to face these tasks of a sustainable personal monitoring requires the introduction of modern electronic dosimeters into to the official monitoring. Doing so, the needed prompt exchange of dose-data between different monitoring services as well as between the customers and the related monitoring service can be warranted. In cooperation with the industry, competent authorities and a research centre a method for official dosimetry using electronic dosimetry systems was developed, realised and tested successfully by the three big monitoring services of Germany. These investigations are supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety. For this purpose a network between customers and monitoring services was built up in order to monitor people, who work in different places related to different measuring bodies in only one period of surveillance. (author)

  11. Effects of the interruption of the irradiation process on PMMA Harwell Industry Dosimetry Systems

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Nowadays, the use of dyed-polymethylmethacrylate dosimetry systems in measurements at industrial irradiations has been broadly, despite the use of alanine dosimeters. Accurate dosimetry measurements are essential for the sterilization applications of medical products as well as the preservation of food by ionizing radiation. Regulations in many countries require in-plant dosimetry to ensure that the specified radiation dose has been delivered to the product. Harwell commercial dosimeters commonly are built to work with measurements between 1 kGy to 50 kGy, this means that a same dosimeter could be used until reach these values. Radiation processing demands partial measurements of the absorbed dose to guarantee the final desired applied absorbed dose depending to the dose rate. In this sense, the total absorbed dose corresponds to the cumulative partial values. In this study, several dosimeters were irradiated at the Multipurpose Gamma Irradiation Facility at IPEN - CNEN/SP to evaluate the response to the interruption of the irradiation process in the total cumulative absorbed dose values considering statistical changes and some processing parameters. When studied the Harwell dyed-polymethylmethacrylate dosimeters Red 4034 and Amber 3042, applying processing interruptions, results shown a coefficient of variation under 7% for industrial irradiation conditions to the total cumulative absorbed dose. (author)

  12. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed

  13. Internal sources dosimetry

    International Nuclear Information System (INIS)

    Savio, Eduardo

    1994-01-01

    The absorbed dose, need of estimation in risk evaluation in the application of radiopharmaceuticals in Nuclear Medicine practice,internal dosimetry,internal and external sources. Calculation methodology,Marinelli model,MIRD system for absorbed dose calculation based on biological parameters of radiopharmaceutical in human body or individual,energy of emitted radiations by administered radionuclide, fraction of emitted energy that is absorbed by target body.Limitation of the MIRD calculation model. A explanation of Marinelli method of dosimetry calculation,β dosimetry. Y dosimetry, effective dose, calculation in organs and tissues, examples. Bibliography .

  14. Type tests performed on a personnel dosimetry system according to IEC 61066

    International Nuclear Information System (INIS)

    Castillo, Romel; Huamanlazo, Paula; Rojas, Enrique

    2015-01-01

    In this study, the verification of the Harshaw 6600 Plus TLD personal dosimetry system was made using the method of the IEC-61066 type tests and the recommendations of the ISO 4037 standards. For this purpose, five dosimeters were irradiated over a water phantom using an irradiator with a 137 Cs source; five dosimeters as control were also used. The evaluated parameters were homogeneity, detection limit, residual reading, linearity, reproducibility, droppings and temperature and humidity variations. The obtained results show that the Harshaw 6600 TLD dosimetric system fulfills the IEC 61066 criteria. (author)

  15. Cyberknife Relative Output Factor measurements using fiber-coupled luminescence, MOSFETS and RADPOS dosimetry system

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Vandervoort, E.

    2012-01-01

    from 5 to 60 mm. ROFs were also measured using a mobileMOSFET system (Best Medical Canada) and EBT1 and EBT2 GAFCHROMIC® (ISP, Ashland) radiochromic films. For cone sizes 12.5–60 mm all detector results were in agreement within the measurement uncertainty. The microMOSFET/RADPOS measurements (published.......3% and 0.865 ± 0.3% for 5, 7.5 and 10 mm cones. Our study shows that the microMOSFET/RADPOS and optical fiber‐coupled RL dosimetry system are well suited for Cyberknife cone output factors measurements over the entire range of field sizes, provided that appropriate correction factors are applied...

  16. Performance comparisons of selected personnel-dosimetry systems in use at Department of Energy facilities

    International Nuclear Information System (INIS)

    Roberson, P.L; Holbrook, K.L.; Yoder, R.C.; Fox, R.A.; Hadley, R.T.; Hogan, B.T.; Hooker, C.D.

    1983-10-01

    Dosimeter performance data were collected to help develop a uniform approach to the calibration and use of personnel dosimetry systems for Department of Energy (DOE) laboratories. Eleven DOE laboratories participated in six months of testing using the American National Draft Standard, Criteria for Testing Personnel Dosimetry Performance, ANSI N13.11, and additional testing categories. The tests described in ANSI N13.11 used a pass/fail system to determine compliance with the draft standard. Recalculation to PNL irradiations showed that the 137 Cs, 90 Sr/ 90 Y, and 252 Cf categories can be recalibrated to have acceptable performance for nearly all participant systems. Deficient dosimeter design or handling techniques caused poor performance in the x-ray category for nearly half of the participants. Too little filtration for the deep-dose element caused poor performance in the beta/photon mixture category for one participant. Two participants had excessively high standard deviations in the neutron category due to dosimeter design or handling deficiencies. The participating dosimetry systems were separated into three categories on their dose evaluation procedure for low-energy photons. These were film dosimeters, fixed-calibration thermoluminescent (TL) dosimeters, and variable-calibration TL dosimeters. The performance of the variable-calibration design was best while the film dosimeters performed considerably worse than either TL dosimeter design. Beta energy dependence studies confirmed a strong correlation between sensitive element thickness, shallow element filtration and low-energy beta response. Studies of neutron calibration conditions for each participant suggested a relationship between response and calibration facility design

  17. Introduction to ISOCAD (Integrated System of Computer Aided Dosimetry)

    International Nuclear Information System (INIS)

    Shrivastava, Amit

    2014-01-01

    A novel, bar code based computerized application package from BRIT for the Ceric cerous Potentiometric Dose Measurement System for Gamma Irradiators. The present generation of gamma irradiators operating worldwide and catering to the radiation processing requirements of medium and high dose products from the healthcare and food processing industry invariably resort to Ceric cerous Potentiometric Dose Measurement Systems (CCPDMs). BRIT, being of the major supplier of this dose measurement system in the country has expanded its clientele to the Asian continent as well in the recent past, had been endeavoring to provide its valued clients this internationally acclaimed dose measurement system at competitive pricing. The perpetually changing quality conscious business environment with demanding cGMP requirements particularly from the healthcare and the food sector propelled the development of the ISOCAD

  18. Practice for use of a ceric-cerous sulfate dosimetry system

    International Nuclear Information System (INIS)

    2002-01-01

    This practice covers the preparation, testing, and procedure for using the ceric-cerous sulfate dosimetry system to measure absorbed dose in water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the ceric-cerous system. It is classified as a reference standard dosimetry system (see ISO/ASTM Guide 51261). Ceric-cerous dosimeters are also used as transfer-standard dosimeters or routine dosimeters. This practice describes both the spectrophotometric and the potentiometric readout procedures for the ceric-cerous systems. This practice applies only to g rays, X rays, and high energy electrons. This practice applies provided the following are satisfied: The absorbed-dose range shall be between 5x10 2 and 5x10 4 Gy. The absorbed-dose rate shall be less than 10 6 Gy/s. For radionuclide gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 8 MeV. The irradiation temperature of the dosimeter shall be between 0 and 62 deg C

  19. The stepping source dosimetry system as an extension of the manchester system

    International Nuclear Information System (INIS)

    Rembowska, A.M.E.; Cook, M.; Hoskin, P.J.; Mahdevan, A.

    1996-01-01

    Brachytherapy based on absolute application of Manchester distribution rules has been used at Mount Vernon Hospital for single and two plane breast implants. Here dwell times are extracted from the required ratio of source activity in the periphery to that at the centre of the implant. Required dwell times can then be calculated directly from the original Manchester tables using a simple formula. Traditionally High Dose Rate Brachytherapy Dosimetry has used equal exposure times at each source dwell position as a starting point, an approach comparable to a Paris type implant. An optimisation system based on introducing constraints into the system can then be applied, however the number and type of constraints are limited, and there is little clinical evidence to justify this approach. The advantages of using Manchester distribution rules in planar implants, where the sources are contained in the target area or volume and also circumscribe it, but do not extend beyond it, together with the homogenous dose distribution achievable, are illustrated, with clinical examples. A proposed distribution, based on this approach for treating a spherical volume typical of planned prostate treatments at this centre is also described

  20. WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, J [University of North Carolina and North Carolina State University, Chapel Hill, NC (United States); Dooley, J; Chang, S [University of North Carolina School of Medicine, Chapel Hill, NC (United States); Belley, M; Yoshizumi, T [Duke University Medical Center, Durham, NC (United States); Stanton, I; Langloss, B; Therien, M [Duke University, Durham, NC (United States)

    2015-06-15

    Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have

  1. BeOSL system for personal dosimetry : dosimetric characteristics and practical application

    International Nuclear Information System (INIS)

    Mende, E.

    2015-10-01

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  2. A microcontroller based lyoluminescence recording system for high dose dosimetry

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Raman, Anand; Oommen, I.K.; Choithramani, S.J.; Sharma, D.N.

    2001-01-01

    This paper describes the features of a microcontroller based lyoluminescence (LL) measurement system which provides the peak yield versus time plot and the integrated light yield of the LL process. The peak yield is found to be a better measure of the LL process as compared to the integrated yield. (author)

  3. A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Sakhalkar, H. S.; Adamovics, J.; Ibbott, G.; Oldham, M. [Department of Radiation Oncology Physics, Duke University Medical Center, Durham, North Carolina 27710 (United States); Department of Chemistry and Biology, Rider University, Lawrenceville, New Jersey 08648 (United States); Department of Radiation Physics, M. D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiation Oncology Physics, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2009-01-15

    This work presents extensive investigations to evaluate the robustness (intradosimeter consistency and temporal stability of response), reproducibility, precision, and accuracy of a relatively new 3D dosimetry system comprising a leuco-dye doped plastic 3D dosimeter (PRESAGE) and a commercial optical-CT scanner (OCTOPUS 5x scanner from MGS Research, Inc). Four identical PRESAGE 3D dosimeters were created such that they were compatible with the Radiologic Physics Center (RPC) head-and-neck (H and N) IMRT credentialing phantom. Each dosimeter was irradiated with a rotationally symmetric arrangement of nine identical small fields (1x3 cm{sup 2}) impinging on the flat circular face of the dosimeter. A repetitious sequence of three dose levels (4, 2.88, and 1.28 Gy) was delivered. The rotationally symmetric treatment resulted in a dose distribution with high spatial variation in axial planes but only gradual variation with depth along the long axis of the dosimeter. The significance of this treatment was that it facilitated accurate film dosimetry in the axial plane, for independent verification. Also, it enabled rigorous evaluation of robustness, reproducibility and accuracy of response, at the three dose levels. The OCTOPUS 5x commercial scanner was used for dose readout from the dosimeters at daily time intervals. The use of improved optics and acquisition technique yielded substantially improved noise characteristics (reduced to {approx}2%) than has been achieved previously. Intradosimeter uniformity of radiochromic response was evaluated by calculating a 3D gamma comparison between each dosimeter and axially rotated copies of the same dosimeter. This convenient technique exploits the rotational symmetry of the distribution. All points in the gamma comparison passed a 2% difference, 1 mm distance-to-agreement criteria indicating excellent intradosimeter uniformity even at low dose levels. Postirradiation, the dosimeters were all found to exhibit a slight increase in

  4. A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system

    International Nuclear Information System (INIS)

    Sakhalkar, H. S.; Adamovics, J.; Ibbott, G.; Oldham, M.

    2009-01-01

    This work presents extensive investigations to evaluate the robustness (intradosimeter consistency and temporal stability of response), reproducibility, precision, and accuracy of a relatively new 3D dosimetry system comprising a leuco-dye doped plastic 3D dosimeter (PRESAGE) and a commercial optical-CT scanner (OCTOPUS 5x scanner from MGS Research, Inc). Four identical PRESAGE 3D dosimeters were created such that they were compatible with the Radiologic Physics Center (RPC) head-and-neck (H and N) IMRT credentialing phantom. Each dosimeter was irradiated with a rotationally symmetric arrangement of nine identical small fields (1x3 cm 2 ) impinging on the flat circular face of the dosimeter. A repetitious sequence of three dose levels (4, 2.88, and 1.28 Gy) was delivered. The rotationally symmetric treatment resulted in a dose distribution with high spatial variation in axial planes but only gradual variation with depth along the long axis of the dosimeter. The significance of this treatment was that it facilitated accurate film dosimetry in the axial plane, for independent verification. Also, it enabled rigorous evaluation of robustness, reproducibility and accuracy of response, at the three dose levels. The OCTOPUS 5x commercial scanner was used for dose readout from the dosimeters at daily time intervals. The use of improved optics and acquisition technique yielded substantially improved noise characteristics (reduced to ∼2%) than has been achieved previously. Intradosimeter uniformity of radiochromic response was evaluated by calculating a 3D gamma comparison between each dosimeter and axially rotated copies of the same dosimeter. This convenient technique exploits the rotational symmetry of the distribution. All points in the gamma comparison passed a 2% difference, 1 mm distance-to-agreement criteria indicating excellent intradosimeter uniformity even at low dose levels. Postirradiation, the dosimeters were all found to exhibit a slight increase in

  5. Development of Instrumental ORAM System for Radiation Dosimetry

    International Nuclear Information System (INIS)

    Bogard, J.S.; Cullum, B.M.; Mobley, J.; Moscovitch, M.; Vo-Dinh, T.

    1999-01-01

    The development of an optical-based dosimeter for neutrons and heavy charged particles is described. It is based on the use of three dimensional (3-D) optical memory materials, used in optical computing applications, and multiphoton fluorescence of photochromic dyes. Development and characterization of various types of dosimeter materials are described as well as the optical readout system. In addition, various excitation geometries for ''reading'' and ''writing'' to the optical memories are also discussed

  6. Recommendations to harmonize European early warning dosimetry network systems

    Science.gov (United States)

    Dombrowski, H.; Bleher, M.; De Cort, M.; Dabrowski, R.; Neumaier, S.; Stöhlker, U.

    2017-12-01

    After the Chernobyl nuclear power plant accident in 1986, followed by the Fukushima Nuclear power plant accident 25 years later, it became obvious that real-time information is required to quickly gain radiological information. As a consequence, the European countries established early warning network systems with the aim to provide an immediate warning in case of a major radiological emergency, to supply reliable information on area dose rates, contamination levels, radioactivity concentrations in air and finally to assess public exposure. This is relevant for governmental decisions on intervention measures in an emergency situation. Since different methods are used by national environmental monitoring systems to measure area dose rate values and activity concentrations, there are significant differences in the results provided by different countries. Because European and neighboring countries report area dose rate data to a central data base operated on behalf of the European Commission, the comparability of the data is crucial for its meaningful interpretation, especially in the case of a nuclear accident with transboundary implications. Only by harmonizing measuring methods and data evaluation, is the comparability of the dose rate data ensured. This publication concentrates on technical requirements and methods with the goal to effectively harmonize area dose rate monitoring data provided by automatic early warning network systems. The requirements and procedures laid down in this publication are based on studies within the MetroERM project, taking into account realistic technical approaches and tested procedures.

  7. UK guidance on the management of personal dosimetry systems for healthcare staff working at multiple organizations.

    Science.gov (United States)

    Rogers, Andy; Chapple, Claire-Louise; Murray, Maria; Platton, David; Saunderson, John

    2017-11-01

    There has been concern expressed by the UK regulator, the Health & Safety Executive, regarding the management of occupation dose for healthcare radiation workers who work across multiple organizations. In response to this concern, the British Institute of Radiology led a working group of relevant professional bodies to develop guidance in this area. The guidance addresses issues of general system management that would apply to all personal dosimetry systems, regardless of whether or not the workers within that system work across organizational boundaries, along with exploring efficient strategies to comply with legislation where those workers do indeed work across organizational boundaries. For those specific instances, the guidance discusses both system requirements to enable organizations to co-operate (Ionising Radiation Regulations 1999 Regulation 15), as well as specific instances of staff exposure. This is broken down into three categories-low, medium and high risk. A suggested approach to each is given to guide employers and their radiation advisers in adopting sensible strategies for the monitoring of their staff and the subsequent sharing of dosimetry data to ensure overall compliance with both dose limits and optimization requirements.

  8. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  9. Pre-clinical evaluation of a diode-based In vivo dosimetry system

    International Nuclear Information System (INIS)

    Trujillo, G.

    1998-01-01

    Diode detector systems are routinely used in a number of departments for the quality assurance of the delivered dose in radiation oncology (1,2,3,4,5). The main advantage of diode detectors for in vivo dosimetry (over TLDs, film dosimetry, ionization chambers) is that results are immediately available in real time, do not need external bias voltage and are more sensitive for the same detection volume than ionization chambers thereby allowing a direct and immediate check of the treatment accuracy. Also, is important to mention that is possible to obtain different accuracy levels. For example, in the case of the measurements designed for evaluating the dosimetric accuracy of a new treatment technique for dose escalation studies the action level should be tighter (the order of 2 % to 4 %, 2 standard deviations) than for routine measurements aiming to discover and correct for errors in the treatment of individual patients (± 5 % - 10 % or to avoid mis administrations (10 % - 15 %). This work describes the calibration method adopted and the evaluation of the accuracy and precision of in vivo dosimetry at Co 60 and 23 MV photon energies. Extensive phantoms measurements were made to determine the influence of physical conditions on the diode response. Parameters investigated included diode linearity, leakage, and measurement reproducibility, as well as the field size, SSD, and angular dependence. the practical consequences of these measurements are reported. There is still some controversy as to whether in vivo (diode) dosemeters are required for routine quality assurance purposes. Our work has shown that while care must be taken in choosing and handling diode detector systems they are able to provide an efficient and effective method of ensuring the dose delivered to the patient during treatment is within acceptable limits. (Author)

  10. Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system.

    Science.gov (United States)

    Aldelaijan, Saad; Devic, Slobodan

    2018-05-01

    Different dose response functions of EBT3 model GafChromic™ film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation. Pieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis. Response functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy. Although reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Lactose and ''tris'' lyoluminescence dosimetry systems and ESR correlation studies

    International Nuclear Information System (INIS)

    Oommen, I.K.; Nambi, K.S.V.; Sengupta, S.; Rao, T.K.G.; Ravikumar, M.

    1989-01-01

    Lyoluminescence (LL) dosimeters have been developed using lactose monohydrate (disaccharide) and tris(hydroxymethyl)aminomethane (''Tris'') systems and attempts have been made to understand the LL mechanism through ESR correlation studies. Tris LL dosimeter has a γ-ray sensitivity with a linear response in the absorbed-dose range 0.05-200 Gy (5-2 x 10 4 rad), while the lactose response extends to a higher range from 1 to 10 4 Gy (10 2 -10 6 rad). The LL output of lactose and Tris did not show any appreciable decay for a period of 6 months after irradiation. ESR measurements show that free-radical concentration in both the systems increases with γ-ray dose in the range 10 2 -10 5 Gy. The minimum dose required to measure the radiation-induced ESR signal for Tris is ∼ 500 Gy, the dose at which the LL output saturates, while lactose shows a radiation-induced ESR signal right at the minimum dose where LL could be detected. The estimated spin density on the radical carbon atom is 0.7. ESR signal stabilities of lactose and Tris were also studied. Lactose did not show any appreciable ESR decay for a period of 3 months after irradiation, while, for Tris, one of the radicals showed a decay of 45% for the same period. (author)

  12. Dosimetry and image quality assessment in a direct radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Paixao, Lucas; Nogueira, Maria do Socorro, E-mail: boliveira.mg@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Oliveira, Marcio Alves de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Anatomia e Imagem; Teixeira, Maria Helena Araujo [Clinica Dra. Maria Helena Araujo Teixeira, Belo Horizonte, MG (Brazil)

    2014-11-15

    Objective: to evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and methods: Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results: considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion: the present study contributes to verify the equipment conformity as regards dose values and image quality. (author)

  13. Personal dosimetry service of TECNATOM: measurement system and methodology of calibration

    International Nuclear Information System (INIS)

    Marchena, Paloma; Bravo, Borja

    2008-01-01

    Full text: The implementation of a new integrated and practical working tool called ALEDIN within the Personal Dosimetry Service (PDS) of TECNATOM, have harmonized the methodology for the counting acquisition, detector calibration and data analysis using a friendly Windows (registered mark) environment. The knowledge of this methodology, due to the fact that is the final product of a R and D project, will help the users and the Regulatory Body for a better understanding of the internal activity measurement in individuals, allowing a more precise error identification and correction, and improving the whole process of the internal dosimetry. The development and implementation of a new calibration system of the whole body counters using NaI (Tl) detectors and the utilization of a new humanoid anthropometric phantom, BOMAB type, with a uniform radioactive source distributions, allow a better energy and activity calibration for different counting geometries covering a wide range of gamma spectra from low energies, less than 100 keV to about 2000 keV for the high energies spectra. This new calibration methodology implied the development of an improved system for the determination of the isotopic activity. This new system has been integrated in a Windows (registered mark) environment, applicable for counting acquisition and data analysis in the whole body counters WBC in cross connection with the INDAC software, which allow the interpretation of the measured activity as committed effective dose following all the new ICRP recommendations and dosimetric models for internal dose and bioassay measurements. (author)

  14. The Mayak Worker Dosimetry System (MWDS-2013): implementation of the dose calculations

    International Nuclear Information System (INIS)

    Zhdanov, A.; Vostrotin, V.; Efimov, A.; Birchall, A.; Puncher, M.

    2017-01-01

    The calculation of internal doses for the Mayak Worker Dosimetry System (MWDS-2013) involved extensive computational resources due to the complexity and sheer number of calculations required. The required output consisted of a set of 1000 hyper-realizations: each hyper-realization consists of a set (1 for each worker) of probability distributions of organ doses. This report describes the hardware components and computational approaches required to make the calculation tractable. Together with the software, this system is referred to here as the 'PANDORA system'. It is based on a commercial SQL server database in a series of six work stations. A complete run of the entire Mayak worker cohort entailed a huge amount of calculations in PANDORA and due to the relatively slow speed of writing the data into the SQL server, each run took about 47 days. Quality control was monitored by comparing doses calculated in PANDORA with those in a specially modified version of the commercial software 'IMBA Professional Plus'. Suggestions are also made for increasing calculation and storage efficiency for future dosimetry calculations using PANDORA. (authors)

  15. Online patient dosimetry and an image quality audit system in digital radiology

    International Nuclear Information System (INIS)

    Fernandez, J. M.; Vano, E.; Ten, J. I.; Prieto, C.; Martinez, D.

    2006-01-01

    The present work describes an online patient dosimetry and an image quality audit system in digital radiology. the system allows auditing of different parameters depending on contents of DICOM (Digital Imaging and Communication in Medicine) header. For the patient dosimetry audit, current mean values of entrance surface dose (ESD) were compared with local and national reference values (RVs) for the specific examination type evaluated. Mean values exceeding the RV trigger an alarm signal and then an evaluation of the technical parameters, operational practice and image quality starts, using data available in the DICOM header to derive any abnormal settings or performance to obtain the image. the X-ray tube output for different kVp values is measured periodically, allowing for the automatic calculation of the ESD. The system also allows for image quality audit linking it with the dose imparted and other technical parameters if the alarm condition if produced. Results and advantages derived from this online quality control are discussed. (Author) 5 refs

  16. Treatment planning systems dosimetry auditing project in Portugal.

    Science.gov (United States)

    Lopes, M C; Cavaco, A; Jacob, K; Madureira, L; Germano, S; Faustino, S; Lencart, J; Trindade, M; Vale, J; Batel, V; Sousa, M; Bernardo, A; Brás, S; Macedo, S; Pimparel, D; Ponte, F; Diaz, E; Martins, A; Pinheiro, A; Marques, F; Batista, C; Silva, L; Rodrigues, M; Carita, L; Gershkevitsh, E; Izewska, J

    2014-02-01

    The Medical Physics Division of the Portuguese Physics Society (DFM_SPF) in collaboration with the IAEA, carried out a national auditing project in radiotherapy, between September 2011 and April 2012. The objective of this audit was to ensure the optimal usage of treatment planning systems. The national results are presented in this paper. The audit methodology simulated all steps of external beam radiotherapy workflow, from image acquisition to treatment planning and dose delivery. A thorax CIRS phantom lend by IAEA was used in 8 planning test-cases for photon beams corresponding to 15 measuring points (33 point dose results, including individual fields in multi-field test cases and 5 sum results) in different phantom materials covering a set of typical clinical delivery techniques in 3D Conformal Radiotherapy. All 24 radiotherapy centers in Portugal have participated. 50 photon beams with energies 4-18 MV have been audited using 25 linear accelerators and 32 calculation algorithms. In general a very good consistency was observed for the same type of algorithm in all centres and for each beam quality. The overall results confirmed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy is generally acceptable with no major causes for concern. This project contributed to the strengthening of the cooperation between the centres and professionals, paving the way to further national collaborations. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Gamma-Ray Dosimetry System Using Radiation-Resistant Optical Fibers and a Luminescent Material

    International Nuclear Information System (INIS)

    Toh, K.; Nakamura, T.; Yamagishi, H.; Sakasai, K.; Soyama, K.; Shikama, T.; Nagata, S.

    2013-06-01

    Gamma-ray dosimetry system using radiation-resistant optical fibers and a luminescent material was developed for use in a damaged Fukushima Dai-ichi nuclear power plant. The system was designed to be compact and unnecessary of an external supply of electricity to a radiation sensor head with a contaminated working environment and restricted through-holes to a measurement point in the damaged reactor. The system can detect a gamma-ray dose rate at a measurement point using a couple of optical fibers and a luminescent material with a coincidence method. This system demonstrated a linear response with respect to the gamma-ray dose rate from 0.5 mGy/h to 0.1 Gy/h and the system had a capability to measure the dose rate of more than 10 2 Gy/h. (authors)

  18. Streamlining the Process of Acquiring Secure Open Architecture Software Systems

    Science.gov (United States)

    2013-10-08

    Microsoft.NET, Enterprise Java Beans, GNU Lesser General Public License (LGPL) libraries, and data communication protocols like the Hypertext Transfer...NetBeans development environments),  customer relationship management (SugarCRM),  database management systems (PostgreSQL, MySQL ),  operating

  19. Development of real-time radiation exposure dosimetry system using synthetic ruby for interventional radiology

    International Nuclear Information System (INIS)

    Hosokai, Yoshiyuki; Win, Thet Pe; Muroi, Kenzo; Matsumoto, Kenki; Takahashi, Kaito; Usui, Akihito; Saito, Haruo; Kozakai, Masataka

    2017-01-01

    Interventional radiology (IVR) tends to involve long procedures, consequently delivering high radiation doses to the patient. Radiation-induced injuries that occur because of the effect of the high radiation doses are a considerable problem for those performing IVR. For example, skin injuries can include skin erythema if the skin is exposed to radiation doses beyond the threshold level of 2 Gy. One of the reasons for this type of injury is that the local skin dose cannot be monitored in real time. Although there are systems employed to measure the exposure dose, some do not work in real time (such as thermoluminescence dosimeters and fluorescent glass dosimeters), while certain real-time measurement systems that enter the field of view (such as patient skin dosimeters and dosimeters using a nontoxic phosphor) interfere with IVR. However, synthetic ruby has been shown to emit light in response to radiation. The luminous wavelength is 693 nm. It is possible to monitor the radiation dose by detecting the emitted light. However, small synthetic rubies emit a tiny amount of light that is difficult to detect using common systems such as photodiodes. A large enough synthetic ruby to increase the quantity of emitted light would however enter the field of view and interfere with the IVR procedure. Additionally, although a photodiode system could reduce the system size, the data is susceptible to effects from the X-rays and outside temperature. Therefore, use of a sensitive photon counting system as used in nuclear medicine could potentially have a beneficial effect in detecting the weak light signal. A real-time radiation exposure dosimetry system for use in IVR should be sufficiently sensitive, not interfere with the IVR procedure, and ideally have the possibility of development into a system that can provide simultaneous multipoint measurements. This article discusses the development of a realtime radiation exposure dosimetry system for use in IVR that employs a small

  20. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    International Nuclear Information System (INIS)

    Hubner, S.

    2014-08-01

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  1. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  2. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Torii, Yoshiya

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  3. Study on the establishment of retrospective dosimetry system for nuclear radiation accident(II)

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jae Shik; Chai, Ha Seok; Lee, Jong Ok [Chungnam National Univ., Taejon (Korea, Republic of)

    1999-03-15

    This study was driven forward centering around physical techniques in retrospective dosimetry system for encountering nuclear radiation accident. The results obtained through this study are summarized as follow : the minimal facilities based on physical techniques should be assured at KINS for appropriate operation and establishment of retrospective accident dosimetry system, the necessary apparatus and man power for retrospective dose assessment by physical techniques might be operated flexibly, however, CL and TL/OSL readers should be equipped with the highest priority, a series of comparative examination of several physical techniques for retrospective dose assessment revealed that most of the irradiated materials around accident sites are usable for the dose assessment, if a priori study on the dosimetrical characteristics of those materials is preceded in accordance with the species of the collectable samples, the results of the study on the CL-dose response and radiation energy dependence of sugar and sorbitol, showed the nonlinearity in CL-dose relationship at the range of low dose(less than 5 Gy), and it led us to perform a study on the correction of the nonlinearity, and in the later study, CL output showed heavy dependence on radiation energy in the energy below around 100 keV and accordingly, a study on the correction for the energy dependence was also carried out, ve were able to obtain good results as a first attempt to carry out such corrections.

  4. A Liquid Scintillator System for Dosimetry of Photon and Proton Beams

    International Nuclear Information System (INIS)

    Beddar S

    2010-01-01

    We have developed a 3D system based on liquid scintillator (LS) for the dosimetry of photon and proton therapy. We have validated the LS detector system for fast and accurate quality assurance of IMRT and proton therapy fields. Further improvements are required to optimize the quantitative analysis of the light output provided by the system in photon beams. We have also demonstrated its usefulness for protons as it can determine the position and the range of proton beams. This system has also been shown to be capable of fast, sub-millimeter spatial localization of proton spots delivered in a 3D volume and could be used for quality assurance of IMPT. Further developments are on-going to measure beam intensities in 3D.

  5. HOW ROMANIAN FINANCIAL AND INTERNAL AUDITORS ACQUIRE ACCOUNTING INFORMATION SYSTEMS KNOWLEDGE AND COMPETENCES?

    OpenAIRE

    Cardos Vasile - Daniel

    2011-01-01

    Research theme - in this article we investigate how Romanian financial and internal auditors acquire accounting information systems knowledge and competences and how they use this knowledge to improve their activity in order to fulfill their mission as required by the professional standards. Objectives - our main purpose is to establish through what type of courses Romanian financial and internal auditors acquiring accounting information systems knowledge and competences and how useful these ...

  6. Dosimetry Service

    CERN Multimedia

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  7. Department of Energy standard for the performance testing of personnel dosimetry systems

    International Nuclear Information System (INIS)

    1986-12-01

    This standard is intended to be used in the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry systems. It is based on the American National Standards Institute's (ANSI) ''Criteria for Testing Personnel Dosimetry Performance,'' ANSI N13.11-1983, recommendations made to DOE in ''Guidelines for the Calibration of Personnel Dosimeters,'' Pacific Northwest Laboratory (PNL)-4515 and comments received during peer review by DOE and DOE contractor personnel. The recommendations contained in PNL-4515 were based on an evaluation of ANSI N13.11 conducted for the Office of Nuclear Safety, DOE, by PNL. Parts of ANSI N13.11 that did not require modification were used essentially intact in this standard to maintain consistency with nationally recognized standards. Modifications to this standard have resulted from several DOE/DOE contractor reviews and a pilot testing session. An initial peer review by selected DOE and DOE contractor representatives on technical content was conducted in 1983. A review by DOE field offices, program offices, and contractors was conducted in mid-1984. A pilot performance testing session sponsored by the Office of Nuclear Safety was conducted in early 1985 by the Radiological and Environmental Sciences Laboratory, Idaho Falls. Results of the pilot test were reviewed in late 1985 by a DOE and DOE contractor committee. 11 refs., 4 tabs

  8. Development and calibration of a routine dosimetry system for radiation processing

    International Nuclear Information System (INIS)

    Ferreira, Danilo Cardenuto

    2013-01-01

    The development and calibration of a routine dosimetry system based on commercial, low cost photodiode (SFH 206) are presented in this work. The dosimeter probe was designed to operate unbiased in the direct current mode. The radiations were performed with Cobalt-60 Panoramic Irradiator facility in the dose-rate range of 8.1 Gy/h - 125 Gy/h. The photocurrents generated in the device, in each dose-rate, were registered with a digital electrometer and stored during the exposure time. The current response of the diode was measured as a function of the time in steps from 1 Gy up to 200 Gy with accumulated dose up to 15 kGy. In this range, the dose-response of the diode, given by the charge as function of dose, was linear with correlation coefficient better than 0.998. These results were compared with those obtained using Gafchromic film dosimetry often used in routine. To monitor possible gamma radiation effects produced on the diode, the current and charge sensitivities were measured as a function of the absorbed dose. For doses up to 15 kGy, it was not observed any radiation damage what confirms the reproducibility of the diode response better than 3 %. Finally, due to the small experimental errors ( 5% ) and good spatial resolution of the diode it was possible to measure the transit dose due to the movement of the Cobalt-60 radioactive source as well the dose rate mapping in the Panoramic Irradiator. (author)

  9. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    CERN Document Server

    Kumada, H; Matsumura, A; Nakagawa, Y; Nose, T; Torii, Y; Uchiyama, J; Yamamoto, K; Yamamoto, T

    2003-01-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is...

  10. Standard Practice for Use of a Lif Photo-Fluorescent Film Dosimetry System

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the handling, testing, and procedure for using a lithium fluoride (LiF)-based photo-fluorescent film dosimetry system to measure absorbed dose (relative to water) in materials irradiated by photons or electrons. Other alkali halides that may also exhibit photofluorescence (for example, NaCl, NaF, and KCl) are not covered in this practice. Although various alkali halides have been used for dosimetry for years utilizing thermoluminescence, the use of photoluminescence is relatively new. 1.2 This practice applies to photo-fluorescent film dosimeters (referred hereafter as photo-fluorescent dosimeters) that can be used within part or all of the following ranges: 1.2.1 Absorbed dose range of 5 10-2 to 3 102 kGy (1-3). 1.2.2 Absorbed dose rate range of 0.3 to 2 10 4 Gy/s (2-5)). 1.2.3 Radiation energy range for photons of 0.05 to 10 MeV (2). 1.2.4 Radiation energy range for electrons of 0.1 to 10 MeV (2). 1.2.5 Radiation temperature range of -20 to +60°C (6,7). 1.3 This standard doe...

  11. Verification of the computational dosimetry system in JAERI (JCDS) for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Kumada, H; Yamamoto, K; Matsumura, A; Yamamoto, T; Nakagawa, Y; Nakai, K; Kageji, T

    2004-01-01

    Clinical trials for boron neutron capture therapy (BNCT) by using the medical irradiation facility installed in Japan Research Reactor No. 4 (JRR-4) at Japan Atomic Energy Research Institute (JAERI) have been performed since 1999. To carry out the BNCT procedure based on proper treatment planning and its precise implementation, the JAERI computational dosimetry system (JCDS) which is applicable to dose planning has been developed in JAERI. The aim of this study was to verify the performance of JCDS. The experimental data with a cylindrical water phantom were compared with the calculation results using JCDS. Data of measurements obtained from IOBNCT cases at JRR-4 were also compared with retrospective evaluation data with JCDS. In comparison with phantom experiments, the calculations and the measurements for thermal neutron flux and gamma-ray dose were in a good agreement, except at the surface of the phantom. Against the measurements of clinical cases, the discrepancy of JCDS's calculations was approximately 10%. These basic and clinical verifications demonstrated that JCDS has enough performance for the BNCT dosimetry. Further investigations are recommended for precise dose distribution and faster calculation environment

  12. Comparisons between direct ion storage and thermoluminescence dosimetry individual monitoring systems, and internet reporting

    International Nuclear Information System (INIS)

    Kiuru, A.; Kahilainen, J.; Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    A new electronic direct ion storage (DIS) dosemeter allows accumulated personal dose equivalent H p (d) at depths of 10 mm and 0.07 mm to be monitored in a few seconds by inserting the dosemeter into a local reader without deleting the accumulated dose. The DIS system meets general requirements on individual monitoring of hospital personnel using ionising radiation. It differs greatly from off-line thermoluminescence dosimetry systems and offers many additional benefits. The non-volatile reading takes only 5 s, is taken as often as needed, and the data are collected into a dose database, where background radiation is subtracted. Individual personnel doses are reported in Intranet as well as on the Internet at regular intervals to the National Regulatory Authorities. (author)

  13. Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.

    Science.gov (United States)

    Marroquin, Elsa Y León; Herrera González, José A; Camacho López, Miguel A; Barajas, José E Villarreal; García-Garduño, Olivia A

    2016-09-08

    Radiochromic film has become an important tool to verify dose distributions for intensity-modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the formation of Newton's rings. Furthermore, the symmetrical design of EBT3 allows the user to eliminate side-orientation dependence. This film and the flatbed scanner, Epson Perfection V750, form a dosimetry system whose intrinsic characteristics were studied in this work. In addition, uncertainties associated with these intrinsic characteristics and the total uncertainty of the dosimetry system were determined. The analysis of the response of the radiochromic film (net optical density) and the fitting of the experimental data to a potential function yielded an uncertainty of 2.6%, 4.3%, and 4.1% for the red, green, and blue channels, respectively. In this work, the dosimetry system presents an uncertainty in resolving the dose of 1.8% for doses greater than 0.8 Gy and less than 6 Gy for red channel. The films irradiated between 0 and 120 Gy show differences in the response when scanned in portrait or landscape mode; less uncertainty was found when using the portrait mode. The response of the film depended on the position on the bed of the scanner, contributing an uncertainty of 2% for the red, 3% for the green, and 4.5% for the blue when placing the film around the center of the bed of scanner. Furthermore, the uniformity and reproducibility radiochromic film and reproducibility of the response of the scanner contribute less than 1% to the overall uncertainty in dose. Finally, the total dose uncertainty was 3.2%, 4.9%, and 5.2% for red, green, and blue channels, respectively. The above uncertainty values were obtained by mini-mizing the contribution to the total dose uncertainty

  14. Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density

    Science.gov (United States)

    Marroquin, Elsa Y. León; Herrera González, José A.; Camacho López, Miguel A.; Barajas, José E. Villarreal

    2016-01-01

    Radiochromic film has become an important tool to verify dose distributions for intensity‐modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the formation of Newton's rings. Furthermore, the symmetrical design of EBT3 allows the user to eliminate side‐orientation dependence. This film and the flatbed scanner, Epson Perfection V750, form a dosimetry system whose intrinsic characteristics were studied in this work. In addition, uncertainties associated with these intrinsic characteristics and the total uncertainty of the dosimetry system were determined. The analysis of the response of the radiochromic film (net optical density) and the fitting of the experimental data to a potential function yielded an uncertainty of 2.6%, 4.3%, and 4.1% for the red, green, and blue channels, respectively. In this work, the dosimetry system presents an uncertainty in resolving the dose of 1.8% for doses greater than 0.8 Gy and less than 6 Gy for red channel. The films irradiated between 0 and 120 Gy show differences in the response when scanned in portrait or landscape mode; less uncertainty was found when using the portrait mode. The response of the film depended on the position on the bed of the scanner, contributing an uncertainty of 2% for the red, 3% for the green, and 4.5% for the blue when placing the film around the center of the bed of scanner. Furthermore, the uniformity and reproducibility radiochromic film and reproducibility of the response of the scanner contribute less than 1% to the overall uncertainty in dose. Finally, the total dose uncertainty was 3.2%, 4.9%, and 5.2% for red, green, and blue channels, respectively. The above uncertainty values were obtained by minimizing the contribution to the total dose

  15. Organ dosimetry

    International Nuclear Information System (INIS)

    Kaul, Dean C.; Egbert, Stephen D.; Otis, Mark D.; Kuhn, Thomas; Kerr, George D.; Eckerman, Keith F.; Cristy, Mark; Ryman, Jeffrey C.; Tang, Jabo S.; Maruyama, Takashi

    1987-01-01

    This chapter describes the technical approach, complicating factors, and sensitivities and uncertainties of calculations of doses to the organs of the A-bomb survivors. It is the object of the effort so described to provide data that enables the dosimetry system to determine the fluence, kerma, absorbed dose, and similar quantities in 14 organs and the fetus, specified as being of radiobiological interest. This object was accomplished through the use of adjoint Monte Carlo computations, which use a number of random particle histories to determine the relationship of incident neutrons and gamma rays to those transported to a target organ. The system uses these histories to correlate externally-incident energy- and angle-differential fluences with the fluence spectrum (energy differential only) within the target organ. In order for the system to work in the most efficient manner possible, two levels of data were provided. The first level, represented by approximately 6,000 random adjoint-particle histories, enables the computation of the fluence spectrum with sufficient precision to provide statistically reliable (± 6 %) mean doses within any given organ. With this limited history inventory, the system can be run rapidly for all survivors. Mean organ dose and dose uncertainty are obtainable in this mode. The second mode of operation enables the system to produce a good approximation to fluence spectrum within any organ or to produce the dose in each of an array of organ subvolumes. To be statistically reliable, this level of detail requires far more random histories, approximately 40,000 per organ. Thus, operation of the dosimetry system in this mode (i.e., with this data set) is intended to be on an as-needed, organ-specific basis, since the system run time is eight times that in the mean dose mode. (author)

  16. Reshaping of computational system for dosimetry in neutron and photons radiotherapy based in stochastic methods - SISCODES

    International Nuclear Information System (INIS)

    Trindade, Bruno Machado

    2011-02-01

    This work shows the remodeling of the Computer System for Dosimetry of Neutrons and Photons in Radiotherapy Based on Stochastic Methods . SISCODES. The initial description and status, the alterations and expansions (proposed and concluded), and the latest system development status are shown. The SISCODES is a system that allows the execution of a 3D computational planning in radiation therapy, based on MCNP5 nuclear particle transport code. The SISCODES provides tools to build a patient's voxels model, to define a treatment planning, to simulate this planning, and to view the results of the simulation. The SISCODES implements a database of tissues, sources and nuclear data and an interface to access then. The graphical SISCODES modules were rewritten or were implemented using C++ language and GTKmm library. Studies about dose deviations were performed simulating a homogeneous water phantom as analogue of the human body in radiotherapy planning and a heterogeneous voxel phantom, pointing out possible dose miscalculations. The Soft-RT and PROPLAN computer codes that do interface with SISCODES are described. A set of voxels models created on the SISCODES are presented with its respective sizes and resolutions. To demonstrate the use of SISCODES, examples of radiation therapy and dosimetry simulations for prostate and heart are shown. Three protocols were simulated on the heart voxel model: Sm-153 filled balloon and P-32 stent, to prevent angioplasty restenosis; and Tl-201 myocardial perfusion, to imaging. Teletherapy with 6MV and 15MV beams were simulated to the prostate, and brachytherapy with I-125 seeds. The results of these simulations are shown on isodose curves and on dose-volume histograms. The SISCODES shows to be a useful tool for research of new radiation therapy treatments and, in future, can also be useful in medical practice. At the end, future improvements are proposed. I hope this work can contribute to develop more effective radiation therapy

  17. Experimental dosimetry in conformal breast teletherapy compared with the planning system

    International Nuclear Information System (INIS)

    Nogueira, Luciana Batista; Silva, Hugo Leonardo Lemos; Passos Ribeiro de Campos, Tarcísio

    2015-01-01

    The objective of this study was to compare and analyse the absorbed dose profiles from the conformal radiotherapy planning and experimental dosimetry taken in a breast anthropomorphic and anthropometric phantom. Conformal radiotherapy planning was elaborated in the Treatment Planning System (TPS). EBT2 Gafchromic radiochromic films were applied as dosimeters, positioned internally and superficially in the breast phantom. The standard radiation protocol was applied in the breast phantom. The films were digitalised, and their responses were analysed in RGB. The optical densities were processed, reproducing the spatial dose distribution. - Highlights: • Distributions of absorbed doses were generated by the TPS and measured by radiochromic films. • The breast phantom simulated a human breast in position for treatment. • A large portion of the glandular tissue absorbed doses that were equivalent to the radiotherapy planning. • There were regions of hot spots and small areas of under dosage in deeper areas at the lung interface

  18. Real-time dosimetry system in catheterisation laboratory: utility as a learning tool in radiation protection

    International Nuclear Information System (INIS)

    Pinto Monedero, M.; Rodriguez Cobo, C.; Pifarre Martinez, X.; Ruiz Martin, J.; Barros Candelero, J.M.; Goicolea Ruigomez, J.; Diaz Blaires, G.; Garcia Lunar, I.

    2015-01-01

    Document available in abstract form only. Full text of publication follows: Workers at the catheter laboratory are among the most exposed to ionising radiation in hospitals. However, it is difficult to be certain of the radiation doses received by the staff, as personal dosemeters are often misused, and thus, the dose history is not reliable. Moreover, the information provided by personal dosemeters corresponds to the monthly accumulated dose, so corrective actions tends to be delayed. The purpose of this work is, on the one hand, to use a real-time dosimetry system to establish the occupational doses per procedure of workers at the catheter laboratories and, on the other hand, to evaluate its utility as a learning tool for radiation protection purposes with the simultaneous video recording of the interventions. (authors)

  19. Calculation of the uncertainty of HP (10) evaluation for a thermoluminescent dosimetry system

    International Nuclear Information System (INIS)

    Ferreira, M.S.; Silva, E.R.; Mauricio, C.L.P.

    2016-01-01

    Full interpretation of dose assessment only can be performed when the uncertainty of the measurement is known. The aim of this study is to calculate the uncertainty of the TL dosimetry system of the LDF/IRD for evaluation of H P (10) for photons. It has been done by experimental measurements, extraction of information from documents and calculation of uncertainties based on ISO GUM. Energy and angular dependence is the most important source to the combined u c (y) and expanded (U) uncertainty. For 10 mSv, it was obtained u c (y) = 1,99 mSv and U = 3,98 mSv for 95% of coverage interval. (author)

  20. Facilities and procedures used for the performance testing of DOE personnel dosimetry systems

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, P.L.; Fox, R.A.; Hogan, R.T.; Holbrook, K.L.; Hooker, C.D.; Yoder, R.C.

    1983-04-01

    Radiological calibration facilities for personnel dosimeter testing were developed at the Pacific Northwest Laboratory (PNL) for the Department of Energy (DOE) to provide a capability for evaluating the performance of DOE personnel dosimetry systems. This report includes the testing methodology used. The informational presented here meets requirements specified in draft ANSI N13.11 for the testing laboratory. The capabilities of these facilities include sealed source irradiations for /sup 137/Cs, several beta-particle emitters, /sup 252/Cf, and machine-generated x-ray beams. The x-ray beam capabilities include filtered techniques maintained by the National Bureau of Standards (NBS) and K-fluorescent techniques. The calibration techniques, dosimeter irradiation procedures, and dose-equivalent calculation methods follow techniques specified by draft ANSI N13.11 where appropriate.

  1. Facilities and procedures used for the performance testing of DOE personnel-dosimetry systems

    International Nuclear Information System (INIS)

    Roberson, P.L.; Fox, R.A.; Hogan, R.T.; Holbrook, K.L.; Hooker, C.D.; Yoder, R.C.

    1983-04-01

    Radiological calibration facilities for personnel dosimeter testing were developed at the Pacific Northwest Laboratory (PNL) for the Department of Energy (DOE) to provide a capability for evaluating the performance of DOE personnel dosimetry systems. This report includes the testing methodology used. The informational presented here meets requirements specified in draft ANSI N13.11 for the testing laboratory. The capabilities of these facilities include sealed source irradiations for 137 Cs, several beta-particle emitters, 252 Cf, and machine-generated x-ray beams. The x-ray beam capabilities include filtered techniques maintained by the National Bureau of Standards (NBS) and K-fluorescent techniques. The calibration techniques, dosimeter irradiation procedures, and dose-equivalent calculation methods follow techniques specified by draft ANSI N13.11 where appropriate

  2. Comparison measurements of the official individual dosimetry systems in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Boehm, J.

    1988-01-01

    At present, about 220,000 radiation workers are subject to individual monitoring of external radiation in the Federal Republic of Germany in accordance with the X-Ray Ordinance and the Radiation Protection Ordinance and the Radiation Protection Ordinance. Each radiation worker must wear at least one individual dosemeter provided by one of the five officially authorized dosemeter services. Requirements for these dosemeter services with respect to technical equipment and personnel are published in the form of a national directive. The five dosemeter services must participate in the comparison measurements for photon radiation with the official dosemeters issued by them. The comparison measurements are organized at least once a year by the Physicalisch-Technische Bundesanstalt (PTB) in agreement with the Federal Minister of Economics. Film dosemeters evaluated with a filter analysis procedure are most frequently used (96.% of all evaluations in 1984) to monitor the whole body exposure to photon radiation. Glass dosemeters play a minor role (0.5%). They are issued by only two officially authorized dosemeter services and are approved for measurements of photons with energies above 45 keV. According to the national directive, thermoluminescence dosemeters may be used only for partial body dosimetry of photon and beta radiation (2.8%). Nuclear track emulsion films are distributed to measure neutrons of energies above 0.5 MeV. A thermoluminescence albedo dosemeter for the measurement of less energetic neutrons is being introduced. The dosimetry systems involved in the comparison measurements and the operational radiation protection monitoring system of the Federal Republic of Germany are described elsewhere. The objective of this work is to describe the performance of the comparison measurements and to give some results obtained from 1979 to 1984

  3. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya; Uchiyama, Junzo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Matsumura, Akira; Yamamoto, Tetsuya; Nose, Tadao [Tsukuba Univ., Tsukuba, Ibaraki (Japan); Nakagawa, Yoshinobu [National Sanatorium Kagawa-Children' s Hospital, Kagawa (Japan); Kageji, Teruyoshi [Tokushima Univ., Tokushima (Japan)

    2003-03-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal in the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System which can support to set the patient to an actual irradiation position swiftly and accurately. This report describes basic design of JCDS and functions in several processing, calculation methods, characteristics and performance of JCDS. (author)

  4. Determination of the components of uncertainty for a dosimetry system in radiation protection

    International Nuclear Information System (INIS)

    Lopez, F.; Cabral, T.S.; Peixoto, J.G.

    2013-01-01

    This work is about the theoretical calculation of uncertainties associated to the dosimetry of photons of a 137 Cs source that will be used in a Dosimetry Laboratory. In this case recognition of the influence quantities that provide most uncertainty and the right choice of resolution of auxiliary equipment to obtain the smallest uncertainties according to the laboratory. (author)

  5. A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bojechko, Casey; Phillps, Mark; Kalet, Alan; Ford, Eric C., E-mail: eford@uw.edu [Department of Radiation Oncology, University of Washington, 1959 N. E. Pacific Street, Seattle, Washington 98195 (United States)

    2015-09-15

    Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into different failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.

  6. Community-acquired pneumonia in older patients: does age influence systemic cytokine levels in community-acquired pneumonia?

    LENUS (Irish Health Repository)

    Kelly, Emer

    2009-03-01

    Community-acquired pneumonia (CAP) is a major cause of death in the elderly. The age-related increase in comorbid illnesses plays a part but the effect of aging on the immune response may be equally important. We aimed to evaluate patients with CAP for evidence of a muted response to infection in elderly patients admitted to hospital compared with a younger patient group.

  7. When Unbiased Probabilistic Learning Is Not Enough: Acquiring a Parametric System of Metrical Phonology

    Science.gov (United States)

    Pearl, Lisa S.

    2011-01-01

    Parametric systems have been proposed as models of how humans represent knowledge about language, motivated in part as a way to explain children's rapid acquisition of linguistic knowledge. Given this, it seems reasonable to examine if children with knowledge of parameters could in fact acquire the adult system from the data available to them.…

  8. 12 CFR 617.7620 - What should the System institution do when it decides to sell acquired agricultural real estate...

    Science.gov (United States)

    2010-01-01

    ... decides to sell acquired agricultural real estate at a public auction? 617.7620 Section 617.7620 Banks and... What should the System institution do when it decides to sell acquired agricultural real estate at a public auction? System institutions electing to sell or lease acquired agricultural real estate or a...

  9. HOW ROMANIAN FINANCIAL AND INTERNAL AUDITORS ACQUIRE ACCOUNTING INFORMATION SYSTEMS KNOWLEDGE AND COMPETENCES?

    Directory of Open Access Journals (Sweden)

    Cardos Vasile - Daniel

    2011-07-01

    Full Text Available Research theme in this article we investigate how Romanian financial and internal auditors acquire accounting information systems knowledge and competences and how they use this knowledge to improve their activity in order to fulfill their mission as required by the professional standards. Objectives our main purpose is to establish through what type of courses Romanian financial and internal auditors acquiring accounting information systems knowledge and competences and how useful these courses are perceived by the auditors. Prior work audit professional organizations prescribed that auditors must acquire, maintain and develop their knowledge and competences. Information technology and information systems are considered to be a main knowledge component of professional development programs. The scientific literature indicates that auditors have to enhance their information systems knowledge in order to cope with the increasing complexity of the client's entities accounting information systems. We consider that our article embraces Curtis et al. (2009 call for research on how auditors obtain information systems knowledge. Methodology an electronic questionnaire was created and sent to Romanian financial and internal auditors, which were required to indicate the number of accounting information systems course they attended and how the knowledge gained improved their activity. Results We concluded that financial auditors acquire accounting information systems knowledge mainly by attending the courses organized by the Chamber of Financial Auditors of Romanian, while internal auditors by attending the course organized by the companies they are working with. Implications - The results of this study might be used by Romanian professional audit organizations in reconsidering their priorities regarding the accounting information systems knowledge and competence needs of their constituents. Originality/Contribution Our study is the first one to

  10. Dosimetry study for a new in vivo X-ray fluorescence (XRF) bone lead measurement system

    International Nuclear Information System (INIS)

    Nie Huiling; Chettle, David; Luo Liqiang; O'Meara, Joanne

    2007-01-01

    A new 109 Cd γ-ray induced bone lead measurement system has been developed to reduce the minimum detectable limit (MDL) of the system. The system consists of four 16 mm diameter detectors. It requires a stronger source compared to the 'conventional' system. A dosimetry study has been performed to estimate the dose delivered by this system. The study was carried out by using human-equivalent phantoms. Three sets of phantoms were made to estimate the dose delivered to three age groups: 5-year old, 10-year old and adults. Three approaches have been applied to evaluate the dose: calculations, Monte Carlo (MC) simulations, and experiments. Experimental results and analytical calculations were used to validate MC simulation. The experiments were performed by placing Panasonic UD-803AS TLDs at different places in phantoms that representing different organs. Due to the difficulty of obtaining the organ dose and the whole body dose solely by experiments and traditional calculations, the equivalent dose and effective dose were calculated by MC simulations. The result showed that the doses delivered to the organs other than the targeted lower leg are negligibly small. The total effective doses to the three age groups are 8.45/9.37 μSv (female/male), 4.20 μSv, and 0.26 μSv for 5-year old, 10-year old and adult, respectively. An approval to conduct human measurements on this system has been received from the Research Ethics Board based on this research

  11. Design project of the dosimetry control system in the independent CO2 loop for cooling the samples irradiated in the RA reactor vertical experimental channels, Vol. V

    International Nuclear Information System (INIS)

    1964-01-01

    Design project of the dosimetry control system in the independent CO 2 loop for cooling the samples irradiated in the RA reactor vertical experimental channels includes the following: calculations of CO 2 gas activity, design of the dosimetry control system, review of the changes that should be done in the RA reactor building for installing the independent CO 2 loop, specification of the materials with cost estimation, engineering drawings of the system [sr

  12. Environmental dosimetry system based on LiF : Mg, Ti (TLD-100)

    International Nuclear Information System (INIS)

    Saez Vergara, J.C.

    1990-01-01

    The report presents the various tests carried out to the characterize a thermoluminescence environmental dosimetry systems, using the phosphor LiF:mg,Ti (TLD-100) in chip form. The holder has been specifically designed in order to obtain simplicity in the operation and to assure correct measurements in terms of the new operational quantities in radiation protection (ICRU-1985). Some topics in TLD Environmental Monitoring are discussed (Dark Current, Reference Light, Zero Reading, Free-in-Air or Phantom Calibration, Fading Correction, Transit Dose, etc.), and the proposed solutions are exposed. The tests performed have been designed to conform with the different existing international Standards and Recommendations (ANSI : N545-1975; IEC: Draft 45B-1987, ISO : DP 8034-19849. The data from an European Interlaboratory Programm (EUR-8932) have been used to evaluate the performance : the TLD System presented is among the best systems using TLD-100. The results obtained in the characterization (linearity, repeatability, detection threshold, residue, angular response, stability of stored information, etc.) show the optimum performance of this dosimetric system in its application to environmental gamma dose monitoring. Based on these results, two operational procedures have been developed for the application of this Dosimetric System, specially in Quality Assurance Monitoring Programs around Nuclear Plants in Spain. (author)

  13. An evaluation of the Panasonic model UD513AC-1 Thermoluminescence Dosimetry system

    International Nuclear Information System (INIS)

    Durrer, R.E. Jr.

    1991-12-01

    An evaluation of the Panasonic UD513AC-1 Thermoluminescence Dosimetry system was performed to determine the system's capabilities as a general purpose thermoluminescence dosimeter measuring device. The tests that were performed included a critique of the user's manual, delimitation of the operating parameters, the quality of construction, and an evaluation of the features that were unique to this system. The UD513AC-1 was found to be an adequate measuring device for most dosimetric applications. It was not well suited for experimental work with thermoluminescence materials due to a low sensitivity displayed by the photomultiplier tube to commonly used materials. The system was well constructed and did not suffer hardware failure during this research. Major attributes of the UD513AC-1 were automatic data storage, highly reproducible heating ramps, an excellent infrared light filter and a unique feature to a single phosphor unit, a dose determination function. Negative aspects of the system included a limited data manipulation capability within the controlling program, a poorly written user's manual, inadequate sensitivity on the part of the photomultiplier tube, and insufficient capability to adjust the hot N 2 gas flow to desired levels

  14. ESR Dosimetry

    International Nuclear Information System (INIS)

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  15. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 7 2155 http://cern.ch/rp-dosimetry

  16. Dosimetry Service

    CERN Multimedia

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service Tel. 7 2155 http://cern.ch/rp-dosimetry

  17. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 72155 http://cern.ch/rp-dosimetry

  18. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  19. Automated surveillance system for hospital-acquired urinary tract infections in Denmark

    DEFF Research Database (Denmark)

    Condell, Orla; Gubbels, Sophie; Nielsen, J

    2016-01-01

    BACKGROUND: The Danish Hospital-Acquired Infections Database (HAIBA) is an automated surveillance system using hospital administrative, microbiological, and antibiotic medication data. AIM: To define and evaluate the case definition for hospital-acquired urinary tract infection (HA-UTI) and to de......BACKGROUND: The Danish Hospital-Acquired Infections Database (HAIBA) is an automated surveillance system using hospital administrative, microbiological, and antibiotic medication data. AIM: To define and evaluate the case definition for hospital-acquired urinary tract infection (HA-UTI......) and to describe surveillance data from 2010 to 2014. METHODS: The HA-UTI algorithm defined a laboratory-diagnosed UTI as a urine culture positive for no more than two micro-organisms with at least one at ≥10(4)cfu/mL, and a probable UTI as a negative urine culture and a relevant diagnosis code or antibiotic...... treatment. UTI was considered hospital-acquired if a urine sample was collected ≥48h after admission and UTI was calculated per 10,000 risk-days. For validation, prevalence was calculated for each day and compared to point prevalence survey (PPS) data. FINDINGS: HAIBA...

  20. Individual Dose Calculations with Use of the Revised Techa River Dosimetry System TRDS-2009D

    Energy Technology Data Exchange (ETDEWEB)

    Degteva, M. O.; Shagina, N. B.; Tolstykh, E. I.; Vorobiova, M. I.; Anspaugh, L. R.; Napier, Bruce A.

    2009-10-23

    An updated deterministic version of the Techa River Dosimetry System (TRDS-2009D) has been developed to estimate individual doses from external exposure and intake of radionuclides for residents living on the Techa River contaminated as a result of radioactive releases from the Mayak plutonium facility in 1949–1956. The TRDS-2009D is designed as a flexible system that uses, depending on the input data for an individual, various elements of system databases to provide the dosimetric variables requested by the user. Several phases are included in the computation schedule. The first phase includes calculations with use of a common protocol for all cohort members based on village-average-intake functions and external dose rates; individual data on age, gender and history of residence are included in the first phase. This phase results in dose estimates similar to those obtained with system TRDS-2000 used previously to derive risks of health effects in the Techa River Cohort. The second phase includes refinement of individual internal doses for those persons who have had body-burden measurements or exposure parameters specific to the household where he/she lived on the Techa River. The third phase includes summation of individual doses from environmental exposure and from radiological examinations. The results of TRDS-2009D dose calculations have demonstrated for the ETRC members on average a moderate increase in RBM dose estimates (34%) and a minor increase (5%) in estimates of stomach dose. The calculations for the members of the ETROC indicated similar small changes for stomach, but significant increase in RBM doses (400%). Individual-dose assessments performed with use of TRDS-2009D have been provided to epidemiologists for exploratory risk analysis in the ETRC and ETROC. These data provide an opportunity to evaluate the possible impact on radiogenic risk of such factors as confounding exposure (environmental and medical), changes in the Techa River source

  1. Establishment of the Dosicard operational dosimetry system in a nuclear studies center

    International Nuclear Information System (INIS)

    Banchetry, C.

    2001-01-01

    Since the decree of March 1999, each employer of the French nuclear industry must set an operational dosimetry in its company. The method is based on electronic dosimeters equipped with alarms and worn by all the employees. The dosimeters are linked to a computer network. The operational dosimetry is recommended, to optimize the protection of workers and limit the doses received, to respect the principle of equity between the workers, to preserve a ''margin of dose'' in case of any unexpected event. The CEA executives have decided to use the EURISYS MESURES DOSICARD as an operational and complementary dosimetry tool. (author)

  2. Commissioning dosimetry and in situ dose mapping of a semi-industrial Cobalt-60 gamma-irradiation facility using Fricke and Ceric-cerous dosimetry system and comparison with Monte Carlo simulation data

    Science.gov (United States)

    Mortuza, Md Firoz; Lepore, Luigi; Khedkar, Kalpana; Thangam, Saravanan; Nahar, Arifatun; Jamil, Hossen Mohammad; Bandi, Laxminarayan; Alam, Md Khorshed

    2018-03-01

    Characterization of a 90 kCi (3330 TBq), semi-industrial, cobalt-60 gamma irradiator was performed by commissioning dosimetry and in-situ dose mapping experiments with Ceric-cerous and Fricke dosimetry systems. Commissioning dosimetry was carried out to determine dose distribution pattern of absorbed dose in the irradiation cell and products. To determine maximum and minimum absorbed dose, overdose ratio and dwell time of the tote boxes, homogeneous dummy product (rice husk) with a bulk density of 0.13 g/cm3 were used in the box positions of irradiation chamber. The regions of minimum absorbed dose of the tote boxes were observed in the lower zones of middle plane and maximum absorbed doses were found in the middle position of front plane. Moreover, as a part of dose mapping, dose rates in the wall positions and some selective strategic positions were also measured to carry out multiple irradiation program simultaneously, especially for low dose research irradiation program. In most of the cases, Monte Carlo simulation data, using Monte Carlo N-Particle eXtended code version MCNPX 2.7., were found to be in congruence with experimental values obtained from Ceric-cerous and Fricke dosimetry; however, in close proximity positions from the source, the dose rate variation between chemical dosimetry and MCNP was higher than distant positions.

  3. In-vivo (entrance) dose measurements in external beam radiotherapy with aqueous FBX dosimetry system

    International Nuclear Information System (INIS)

    Semwal, M.K.; Thakur, P.K.; Bansal, A.K.; Vidyasagar, P.B.

    2005-01-01

    FBX aqueous chemical dosimetry system has been found useful in radiotherapy owing to its low dose measuring capability. In the present work, entrance dose measurements in external beam radiotherapy on a telecobalt machine were carried out with the system on 100 patients. Treatments involving simple beam arrangement of open parallel-opposed beams in cranial and pelvic irradiations were selected for this study. In place of a spectrophotometer, a simple and inexpensive colorimeter was used for absorbance measurements. The purpose was to assess the efficacy of the FBX system for in-vivo dose measurements. The results obtained show that the average discrepancy between the measured and expected dose for both categories of patients was 0.2% (standard deviation 3.2%) with a maximum of +1 0.3%. There were 5.5% cases showing more than ± 5% discrepancy. Comparison of the results obtained with published work on entrance dose measurements, with diode detectors, shows that the inexpensive FBX system can be used for in-vivo (entrance) dose measurements for simple beam arrangements in radiotherapy and can thus serve as a useful QA tool. (author)

  4. Development of a calorimetric system for electron beam dosimetry in radiation processing

    International Nuclear Information System (INIS)

    Banados P, H.E.

    1994-01-01

    A calorimetric system for electron beam dosimetry in radiation processing was developed. The system is composed of a graphite core calorimeter, the temperature measuring and electrical calibrating instrumentation, a microcomputer and the software for the system automation. The research aimed at the optimization of the project parameters, the development of advanced methodologies for calibrating the temperature sensor, the determination of the thermal capacity as a function of the temperature, the measurement of the absorbed dose, and the development of the software needed for the system operation. The operating range extends from 0.1 kGy to 30 kGy. The uncertainty in the measurement of the absorbed dose was estimated to be ± 1.8% at the 95% confidence level. Comparative tests of the absorbed dose measurements were made using the IPEN electron accelerator. The results obtained showed an excellent agreement between the absorbed dose determined by the calorimeter and the absorbed dose calculated from the nominal power delivered by the accelerator. (author). 67 refs, 63 figs, 2 tabs

  5. Accreditation of a system of extremity dosimetry: validation and uncertainty of method; Acreditacion de un sistema de dosimetria de extremidades: validacion e incertidumbre del metodo

    Energy Technology Data Exchange (ETDEWEB)

    Romero Gutierrez, A. M.; Rodriguez Jimenez, R.; Lopez Moyano, J. L.

    2013-07-01

    The authors' goal is to spread the practical experience gained during the accreditation process paying special attention to the process of method validation and estimation uncertainty of the dosimetry system. (Author)

  6. The burden and epidemiology of community-acquired central nervous system infections

    DEFF Research Database (Denmark)

    Erdem, H; Inan, A; Guven, E

    2017-01-01

    Risk assessment of central nervous system (CNS) infection patients is of key importance in predicting likely pathogens. However, data are lacking on the epidemiology globally. We performed a multicenter study to understand the burden of community-acquired CNS (CA-CNS) infections between 2012...

  7. Risks of circulatory diseases among Mayak PA workers with radiation doses estimated using the improved Mayak Worker Dosimetry System 2008

    Energy Technology Data Exchange (ETDEWEB)

    Moseeva, Maria B.; Azizova, Tamara V.; Grigoryeva, Evgenia S. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Haylock, Richard [Public Health of England, London (United Kingdom)

    2014-05-15

    The new Mayak Worker Dosimetry System 2008 (MWDS-2008) was published in 2013 and supersedes the Doses-2005 dosimetry system for Mayak Production Association (PA) workers. It provides revised external and internal dose estimates based on the updated occupational history data. Using MWDS-2008, a cohort of 18,856 workers first employed at one of the main Mayak PA plants during 1948-1972 and followed up to 2005 was identified. Incidence and mortality risks from ischemic heart disease (IHD) (International Classification of Diseases (ICD)-9 codes 410-414) and from cerebrovascular diseases (CVD) (ICD-9 codes 430-438) were examined in this cohort and compared with previously published risk estimates in the same cohort based on the Doses-2005 dosimetry system. Significant associations were observed between doses from external gamma-rays and IHD and CVD incidence and also between internal doses from alpha-radiation and IHD mortality and CVD incidence. The estimates of excess relative risk (ERR)/Gy were consistent with those estimates from the previous studies based on Doses-2005 system apart from the relationship between CVD incidence and internal liver dose where the ERR/Gy based on MWDS-2008 was just over three times higher than the corresponding estimate based on Doses-2005 system. Adjustment for smoking status did not show any effect on the estimates of risk from internal alpha-particle exposure. (orig.)

  8. 12 CFR 617.7610 - What should the System institution do when it decides to sell acquired agricultural real estate?

    Science.gov (United States)

    2010-01-01

    ... decides to sell acquired agricultural real estate? 617.7610 Section 617.7610 Banks and Banking FARM CREDIT... institution do when it decides to sell acquired agricultural real estate? (a) Notify the previous owner, (1) Within 15 days of the System institution's decision to sell acquired agricultural real estate, it must...

  9. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    CERN Document Server

    Kumada, H

    2002-01-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to ...

  10. Neutron dosimetry system SAIPS: Manual for users and programmers (Version 87-02)

    International Nuclear Information System (INIS)

    Berzonis, M.A.; Bondars, Kh.Ya.; Niedritis, A.M.

    1988-07-01

    SAIPS is a system used for neutron dosimetry by foil activation, containing a package of programs and a data base of neutron activation cross-sections. A description is given of the SAIPS indexed procedures and users language, which are designed for producing input data for programs unfolding neutron spectra from reaction rate measurements, for carrying out calculations and processing and comparing the results obtained, for utilizing the additional capabilities of the system, and for setting up a working version of the system from the magnetic tapes used for distribution. A description is given of the logical structure of the data sets containing the libraries of neutron cross-section and a priori spectra and also the libraries of calculated spectra. The annexes give examples of SAIPS in use, of the contents of the a priori spectra and neutron cross-section libraries, and of the contents of the SAIPS distribution tapes. SAIPS contains programs in PL/1 (opt), FORTRAN IV(H) and ASSEMBLER. 25 refs

  11. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  12. Nuclear accident dosimetry systems: U.K. measurements at the sixteenth intercomparison at O.R.N.L. August 1979

    International Nuclear Information System (INIS)

    Delafield, H.J.; Gibson, J.A.B.; Holt, P.D.; Harrison, K.G.

    1980-04-01

    The results are presented of the measurements made by the A.E.R.E., Harwell participants at the Intercomparison of Nuclear Accident Dosimetry Systems held at the Dosimetry Applications Research Facility (DOSAR) of the Oak Ridge National Laboratory, USA from 13 - 17 August 1979. The source of pulsed radiation used was the Health Physics Research Reactor which was operated bare for pulse 1, and shielded by concrete (20cm thickness) and steel (5cm thickness) for pulses 2 and 3 respectively. Measurements are reported which were made using personnel dosimeters (both in free-air and on phantoms) and a threshold detector system and compared with the provisional results given by the DOSAR group at the meeting. (U.K.)

  13. Occupational dosimetry in real time hemodynamic rooms. utility of the system Dose-aware as a training tool

    International Nuclear Information System (INIS)

    Pinto Monedero, M.; Rodriguez Cobo, C.; Pifarre Martinez, X.; Ruiz Martin, J.; Barros Candelero, J. M.; Goicolea Ruigomez, J.; Diaz Blaires, G.; Garcia Lunar

    2014-01-01

    This paper presents the results from a study in a real time dosimetry system used in the catheter laboratory room of our center. The objective was to know the occupational doses per procedure, on the one hand, and, on the other hand, to evaluate its utility as a learning tool for radiation protection purposes with the simultaneous video recording of the interventions. 83 diagnostic and therapeutic procedures were analyzed, and an average dose per procedure of 0,37 μSv and 0,10 μSv for the main cardiologist and nurse were obtained, respectively. 36 of these interventions were also recorded and the images were synchronized with the dosimetric information stored and the dosimetry system. The findings were presented to the interventional cardiology team in a learning session. They showed a high level of satisfaction with this new method of optimizing the occupational doses through a customized learning session. (Author)

  14. Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance.

    Science.gov (United States)

    Narayanasamy, Ganesh; Zalman, Travis; Ha, Chul S; Papanikolaou, Niko; Stathakis, Sotirios

    2015-05-08

    The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose comparisons in a plane, Dosimetry Check system produces isodose lines and dose-volume histograms based on the planning CT images. By exporting the dose distribution from the treatment planning system into the Dosimetry Check system, one is able to make a direct comparison between the calculated dose and the planned dose. The versatility of the software is evaluated with respect to the two IMRT techniques - step and shoot and volumetric arc therapy. The system analyzed measurements made using EPID, PTW seven29, and IBA MatriXX, and an intercomparison study was performed. Plans from patients previously treated at our institution with treated anatomical site on brain, head & neck, liver, lung, and prostate were analyzed using Dosimetry Check system for any anatomical site dependence. We have recommendations and possible precautions that may be necessary to ensure proper QA with the Dosimetry Check system.

  15. Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

    International Nuclear Information System (INIS)

    Lalonde, Michel; Alexander, Kevin; Olding, Tim; Schreiner, L. John; Kerr, Andrew T.

    2016-01-01

    Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV MET ) and whole brain plus metastases (WB+PTV MET ) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV MET structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV MET iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV MET delivery. But, film doses for PTV MET only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

  16. Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

    Energy Technology Data Exchange (ETDEWEB)

    Lalonde, Michel; Alexander, Kevin; Olding, Tim; Schreiner, L. John; Kerr, Andrew T. [Cancer Centre of Southeastern Ontario at KGH, Queen’s University (Canada)

    2016-08-15

    Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV{sub MET}) and whole brain plus metastases (WB+PTV{sub MET}) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV{sub MET} structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV{sub MET} iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV{sub MET} delivery. But, film doses for PTV{sub MET} only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

  17. A radiophotoluminescent glass plate system for medium-sized field dosimetry

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Koyanagi, Hiroki; Shiraki, Takashi; Saegusa, Shigeki; Sasaki, Katsutake; Oritate, Takashi; Mima, Kazuo; Miyazawa, Masanori; Ishidoya, Tatsuyo; Ohtomo, Kuni; Yoda, Kiyoshi

    2005-01-01

    A two-dimensional radiophotoluminescent system for medium-sized field dosimetry has been developed using a silver-activated phosphate glass plate with a dimension of 120 mmx120 mmx1 mm and a readout unit comprising a UV excitation lamp and a CCD imager. A dose ranging from 0 to 400 cGy, provided by a 6 MV x-ray beam, was delivered to the glass plate oriented perpendicularly to the beam and positioned in a water phantom at a depth of 10 cm, where the center of the glass plate coincided with the linac isocenter. After the dose delivery, the glass plate was placed in the readout system. The CCD output intensity increased linearly with the applied dose. The angular dependence of response on the direction of radiation incidence was measured by rotating the glass plate in the water phantom, indicating that the output remained constant up to 75 deg. from perpendicular incident direction, followed by a steep reduction down to 85% at an angle of 90 deg. A lateral dose distribution resulting from a 60 mmx60 mm irradiation was compared between the glass plate and an x-ray film having had the same exposure, showing that the glass plate and the x-ray film led to identical dose distributions. The dose reproducibility for a glass plate and the sensitivity variation among different glass plates were also evaluated

  18. The calibration method for personal dosimetry system in photon and neutron radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J; Plichta, J [CSOD, Prague (Czech Republic); Nikodemova, D [SOD, Bratislava (Slovakia)

    1996-12-31

    The type testing of dosimetry system was performed with standard photon radiation fields within the energy range 15 keV to 1.25 MeV and electron radiation fields within the range 0.2 MeV to 3 MeV. For type testing of neutron dosimeters {sup 252}Cf and {sup 241}Am-Be radionuclide neutron sources was used, as well as a 14 MeV neutron generator. The neutron sources moderated by various moderating and absorbing materials was also used. The routine calibration of individual photon dosemeters was carried out using a {sup 137}Cs calibration source in the air kerma quality in the dose range 0.2 mGy to 6 Gy. The type testing of neutron dosemeters was performed in collaboration with Nueherberg laboratory on neutron generator with neutron energies -.57; 1.0;; 5.3 and 15.1 MeV. The fading and angular dependence testing was also included in the tests of both dosemeter systems. (J.K.).

  19. Distinction of metaphases in the first cell cycle for automated system in radiation dosimetry

    International Nuclear Information System (INIS)

    Hayata, I.; Kajima, J.; Okabe, N.

    1992-01-01

    As part of the biological improvements for developing an automated scoring system of radiation induced chromosome aberrations for radiation dosimetry, we introduce a new method for identifying the metaphases in the first cell cycle. Differing from the conventional method with BrdUrd, it focuses on the difference of chromosome number to be induced by inhibiting the cytokinesis with Cytochalasin B. Majority of the cells with 46 chromosomes were in the first cell cycle, and the ratio of those with 46 chromosomes in the second division was less than one per cent both when Cytochalasin B of 1.5 μg/ml was added to the culture of irradiated lymphocytes and when that of 1.8 μg/ml was added to that of non-irradiated cells for one day, respectively. The ratio of metaphases with over-condensed chromosomes is reduced, the clear-cut image of chromosomes is obtained, culture and staining processes are simpler, and the device of UV irradiation is not necessary. Thus the present Cytochalasin B method offers more qualified input, data based on the numerical difference, than conventional image based recognition, and upgrades the quality of the scoring in the automated analysis system. (Author)

  20. In Vivo Diode Dosimetry for Imrt Treatments Generated by Pinnacle Treatment Planning System

    International Nuclear Information System (INIS)

    Alaei, Parham; Higgins, Patrick D.; Gerbi, Bruce J.

    2009-01-01

    Dose verification using diodes has been proposed and used for intensity modulated radiation therapy (IMRT) treatments. We have previously evaluated diode response for IMRT deliveries planned with the Eclipse/Helios treatment planning system. The Pinnacle treatment planning system generates plans that are delivered in a different fashion than Eclipse. Whereas the Eclipse-generated segments are delivered in organized progression from one side of each field to the other, Pinnacle-generated segments are delivered in a much more randomized fashion to different areas within the field. This makes diode measurements at a point more challenging because the diode may be exposed fully or partially to multiple small segments during one single field's treatment as opposed to being exposed to very few segments scanning across the diode during an Eclipse-generated delivery. We have evaluated in vivo dosimetry for Pinnacle-generated IMRT plans and characterized the response of the diode to various size segments on phantom. We present results of patient measurements on approximately 300 fields, which show that 76% of measurements agree to within 10% of the treatment-plan generated calculated doses. Of the other 24%, about 11% are within 15% of the calculated dose. Comparison of these with phantom measurements indicates that many of the discrepancies are due to diode positioning on patients and increased diode response at short source-to-surface distances (SSDs), with the remainder attributable to other factors such as segment size and partial irradiation of the diode

  1. An application of artificial neural intelligence for personal dose assessment using a multi-area OSL dosimetry system

    International Nuclear Information System (INIS)

    Lee, S.-Y.Sang-Yoon.; Kim, B.-H.Bong-Hwan; Lee, K.J.Kun Jai

    2001-01-01

    Significant advances have been made in recent years to improve measurement technology and performance of phosphor materials in the fields of optically stimulated luminescence (OSL) dosimetry. Pulsed and continuous wave OSL studies recently carried out on α-Al 2 O 3 : C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of the study is to propose a new personal dosimetry system using α-Al 2 O 3 : C by taking advantage of its optical properties and energy dependencies. In the process of the study, a new dose assessment algorithm was developed using artificial neural networks in hopes of achieving a higher degree of accuracy and precision in personal OSL dosimetry system. The original hypothesis of this work is that the spectral information of an X- and γ-ray fields may be obtained by the analysis of the response of a multi-element system. In this study, a feedforward neural network using the error back-propagation method with Bayesian optimization was applied for the response unfolding procedure. The validation of the proposed algorithm was investigated by unfolding the 10 measured responses of α-Al 2 O 3 : C for arbitrarily mixed photon fields which range from 20 to 662 keV

  2. Scintillator-CCD camera system light output response to dosimetry parameters for proton beam range measurement

    Energy Technology Data Exchange (ETDEWEB)

    Daftari, Inder K., E-mail: idaftari@radonc.ucsf.edu [Department of Radiation Oncology, 1600 Divisadero Street, Suite H1031, University of California-San Francisco, San Francisco, CA 94143 (United States); Castaneda, Carlos M.; Essert, Timothy [Crocker Nuclear Laboratory,1 Shields Avenue, University of California-Davis, Davis, CA 95616 (United States); Phillips, Theodore L.; Mishra, Kavita K. [Department of Radiation Oncology, 1600 Divisadero Street, Suite H1031, University of California-San Francisco, San Francisco, CA 94143 (United States)

    2012-09-11

    The purpose of this study is to investigate the luminescence light output response in a plastic scintillator irradiated by a 67.5 MeV proton beam using various dosimetry parameters. The relationship of the visible scintillator light with the beam current or dose rate, aperture size and the thickness of water in the water-column was studied. The images captured on a CCD camera system were used to determine optimal dosimetry parameters for measuring the range of a clinical proton beam. The method was developed as a simple quality assurance tool to measure the range of the proton beam and compare it to (a) measurements using two segmented ionization chambers and water column between them, and (b) with an ionization chamber (IC-18) measurements in water. We used a block of plastic scintillator that measured 5 Multiplication-Sign 5 Multiplication-Sign 5 cm{sup 3} to record visible light generated by a 67.5 MeV proton beam. A high-definition digital video camera Moticam 2300 connected to a PC via USB 2.0 communication channel was used to record images of scintillation luminescence. The brightness of the visible light was measured while changing beam current and aperture size. The results were analyzed to obtain the range and were compared with the Bragg peak measurements with an ionization chamber. The luminescence light from the scintillator increased linearly with the increase of proton beam current. The light output also increased linearly with aperture size. The relationship between the proton range in the scintillator and the thickness of the water column showed good linearity with a precision of 0.33 mm (SD) in proton range measurement. For the 67.5 MeV proton beam utilized, the optimal parameters for scintillator light output response were found to be 15 nA (16 Gy/min) and an aperture size of 15 mm with image integration time of 100 ms. The Bragg peak depth brightness distribution was compared with the depth dose distribution from ionization chamber measurements

  3. [Systemic lupus erythematosus masking the acquired immunodeficiency syndrome. A report on four cases].

    Science.gov (United States)

    Kotyla, Przemysław; Kucharz, Eugeniusz J

    2012-01-01

    Systemic lupus erythematosus (SLE) is a systemic inflammatory disease of connective tissue with an unknown etiology and a rich clinical picture with involvement of multiple organs. Given the rich symptomatology, application of the current classification criteria is associated with a significant risk of attributing symptoms of other pathologies to lupus and/or other connective tissue disease. Inherited and acquired immune deficiencies may sometimes demonstrate a lupus-like clinical symptomatology. In this work we reviewed 4 of cases referred to the Department of Internal Diseases and Rheumatology of the Silesian Medical University in Katowice with suspected or confirmed systemic lupus erythematosus. A positive anti-HIV antibody test led to the diagnosis of the acquired immunodeficiency syndrome (AIDS). Due to the close similarity of the clinical picture and the presence of antinuclear antibodies in both diseases, the authors postulate that the anti-HIV antibody test should be done routinely in patients with connective tissue diseases.

  4. Test of an albedo neutron dosimetry system: TLD calibration and readout procedure, neutron calibration, dosimetry properties, routine application

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1988-03-01

    The two-component albedo dosemeter in use consists of an universal boron-loaded plastic encapsulation, the beta and albedo neutron windows of which are adopted to the corresponding TLD system of the manufacturers Alnor, Harshaw, Panasonic and Vinten. Beside the TLD detectors the capsule may contain also track etch detectors. Within a BMU project the system was investigated by four governmental measurement services in the FRG with respect to its qualification for personnel monitoring with emphasis in the readout and calibration procedures for the TLD system, the evaluation technique for the estimation of the photon and neutron dose equivalent in routine monitoring and the calibration of the personnel dosemeter in stray neutron fields. The test has shown the readiness of the system to act in the application areas of nuclear power reactors and linacs behind heavy shieldings, in the fuel element cycle, use of fissile materials, criticality, use of radionuclide sources, high energy particle accelerators. The uncertainty due to energy dependence was found to be within a factor of 2 for a single application area. In the case of irradiations from the front half space the dose equivalent H'(10) is indicated sufficiently independent of the direction of the radiation incidence. After completion of the test the albedo dosemeter became the official neutron personnel dosemeter in the FRG. It allows the separate estimation of the dose equivalent of hard beta radiation, photon radiation and neutrons. (orig./HP) [de

  5. A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry

    International Nuclear Information System (INIS)

    Adolfsson, Emelie; Gustafsson, Håkan; Lund, Eva; Alm Carlsson, Gudrun; Olsson, Sara; Carlsson Tedgren, Åsa

    2014-01-01

    Summary: The aim of this work was to develop and test a remote end-to-end audit system using lithium formate EPR dosimeters. Four clinics were included in a pilot study, absorbed doses determined in the PTV agreed with TPS calculated doses within ±5% for 3D-CRT and ±7% (k = 1) for IMRT/VMAT dose plans

  6. Dosimetry methods

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  7. Developing of an automation for therapy dosimetry systems by using labview software

    Science.gov (United States)

    Aydin, Selim; Kam, Erol

    2018-06-01

    Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. Therefore it is very important to provide reliable, accurate and fast calibration services for therapy dosimeters since the radiation dose delivered to a radiotherapy patient is directly related to accuracy and reliability of these devices. In this study, we report the performance of in-house developed computer controlled data acquisition and monitoring software for the commercially available radiation therapy electrometers. LabVIEW® software suite is used to provide reliable, fast and accurate calibration services. The software also collects environmental data such as temperature, pressure and humidity in order to use to use these them in correction factor calculations. By using this software tool, a better control over the calibration process is achieved and the need for human intervention is reduced. This is the first software that can control frequently used dosimeter systems, in radiation thereapy field at hospitals, such as Unidos Webline, Unidos E, Dose-1 and PC Electrometers.

  8. Setting-Up Of A Film Dosimetry System For High Energy Electron Beams And Development Of Computer Programs For Data Processing

    International Nuclear Information System (INIS)

    Schwob, N.; Schwob, W.; Loewenthal, E.

    1999-01-01

    Film dosimetry has the advantage over other dosimetry methods, of having a high spatial resolution and a fast two dimensional data acquisition. We have set up a system using a film digitizer with its associated software, dedicated to radiosurgery and we have developed data processing programs in Visual Basic for Excel. Data acquisition is not limited to water equivalent media: correction factors can be provided in the data processing procedure

  9. Speech and language therapists' views about AAC system acceptance by people with acquired communication disorders.

    Science.gov (United States)

    Pampoulou, Eliada

    2018-04-18

    Some adults with acquired communication disorders are faced with an inability to communicate coherently through verbal speech with their communication partners. Despite the fact that a variety of augmentative and alternative communication (AAC) aided systems is available to assist them in communicating, not all adults accept them. In Cyprus, there is scant research focusing on the factors that are linked to AAC system acceptance and abandonment. To address this gap, this research involves exploring the experiences of six speech and language therapists supporting adults with acquired communication disorders, who could benefit from the use of AAC systems. The main research question is: What are the factors that influence AAC system acceptance or abandonment? The method used for data collection, was semi-structured interviews and the transcripts were analyzed thematically. The findings show that a number of factors influence the acceptance of AAC systems. These include the time since onset and acceptance of disability, the person's attitude towards communication facilitators, and the perceptions about AAC systems. These findings indicate that the process of accepting an AAC system is multi-layered and these layers are interrelated. More research is warranted focusing directly on the experiences of people with acquired communication disorders and their communication partners. Implications for Rehabilitation The different myths about AAC systems need to be challenged such that awareness about their usefulness is raised. AAC specialists need to find ways to spread the message that AAC systems can actually support language, speech and communication through different dissemination avenues, such as articles in newspapers and talks through the media.

  10. A Low Cost 3D Acquiring System for Mushroom Robot Based on Webcam and Line Laser

    Directory of Open Access Journals (Sweden)

    Gang Sun

    2014-03-01

    Full Text Available This paper presents a low cost 3D acquiring system for mushroom robot based on webcam and line laser. The system comprises Webcam, semiconductor line laser, motion platform and data process unit. The system can get the 3D information of the Pleurotus eryngii in bottle based on structured light scanning theory. Field test shows the accuracy of the height is less than 2mm and it can be use to locate the buds in the bottle correctly. It has the potention to fulfill the requirement of the location of the mushroom for thinning bud robot.

  11. Identification of Conflicts between Transmission and Distribution System Operators when Acquiring Ancillary Services from Electric Vehicles

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Knezovic, Katarina; Marinelli, Mattia

    2017-01-01

    ancillary services from flexible units. The investigation is carried out considering a 3-area power system which allows to take into account local constraints as well as system-wide needs. As outcome, this paper identifies the conflicts from both a theoretical and a practical point of view, by means...... products according to requests coming from both distribution and transmission system operators. The goal of this paper is to provide an identification procedure that is able to detect, identify and catalogue possible conflicts among the involved stakeholders that take place when requesting and/or acquiring...

  12. Alanine EPR dosimetry of therapeutic irradiators

    International Nuclear Information System (INIS)

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  13. Development of a lyoluminescence dosimetry system for the radiation processing of food

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Mallard, J.R.; Srirath, S.; Takavar, A.

    1978-01-01

    A new system of solid-state dosimetry is being developed aimed at the radiation processing of food. The system is based on the effect of lyoluminescence, i.e. emission of light when previously irradiated solids are dissolved in water or other solvents. The physical mechanism is based on the formation of free radicals in the solid, which are stable over periods ranging from days to years. These radicals are set free on dissolution and as a result of chemical reactions taking place in a solution light is produced. The dose response of lyoluminescent phosphors is monotonic, and often almost linear, over a very broad range of radiation doses. Amongst saccharides mannose can be used up to about 90krad, trehalose dihydrate up to 250krad and glucose to about 300krad. Amino acids exhibit a broader range: glutamine and glutamic acid can be used up to at least 4Mrad and threonine up to about 1Mrad. In addition, most of naturally occurring soluble amino acids are suitable in a range of doses below 200krad. Soluble starch (amylodextrin) has been successfully tried in a range up to 3Mrad. The intrinsic precision of the method is fairly high and the present uncertainty of the determination of dose, which is 2-4%, appears to be caused by the non-homogeneity of available phosphor and by insufficient reproducibility of the process of dissolution. The lower limit of doses is set by the sensitivity of the read-out equipment. For a simple arrangement with an uncooled PM tube and glutamine as a phosphor a reproducibility of 2-3% is reached for doses in excess of 600rads. The fading of irradiated phosphors is reproducible. A typical value for mannose is 10-15% during the first week and 20-30% during the first year for dosimeters stored at room temperature

  14. Comparison of intraoperative dosimetric implant representation with postimplant dosimetry in patients receiving prostate brachytherapy.

    Science.gov (United States)

    Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G

    2003-01-01

    To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (psystem provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.

  15. The experience from operation of electronic personal dosimetry system at Dukovany, Temelin and Mochovce NPPs after repair of Siemens dosemeters eliminating false doses

    International Nuclear Information System (INIS)

    Malysak, J.; Kocvara, S.; Jurochova, B.; Zelenka, Z.; Schacherl, M.; Zrubec, M.; Kaiser, H.

    2003-01-01

    This presentation summarizes the operational experience of the Electronic Personal Dosimetry Systems installed at Dukovany, Temelin and Mochovce NPPs. The system consists of three basic parts: Electronic personal dosemeters (EPD); Physical layer (HW); Logical layer (SW). Number of false doses before and after correction is presented. This presentation has demonstrated the possibilities of SEOD system and the possibility of easy dose comparison between the individual NPPs after introducing this electronic dosimetry system. Basically, the results of film and electronic dosimetry systems are according to our findings nearly identical. Electronic dosemeter sensitivity to interfering electromagnetic fields is a problem which is easily re-movable. In addition, if we know this problem, these false doses in the SEOD system can be easily revealed (e.g. by investigation of histograms) and repaired

  16. Clinical dosimetry

    International Nuclear Information System (INIS)

    Rassow, J.

    1973-01-01

    The main point of this paper on clinical dosimetry which is to be understood here as application of physical dosimetry on accelerators in medical practice, is based on dosimetric methodics. Following an explanation of the dose parameters and description of the dose distribution important for clinical practice as well as geometric irradiation parameters, the significance of a series of physical parameters such as accelerator energy, surface energy of average stopping power etc. is dealt with in detail. Following a section on field homogenization with bremsstrahlung and electron radiation, details on dosimetry in clinical practice are given. Finally, a few problems of dosemeter or monitor calibration on accelerators are described. The explanations are supplemented by a series of diagrams and tables. (ORU/LH) [de

  17. Image in nuclear dosimetry using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Guinsburg, G.; Matsuoka, M.; Watanabe, S.

    1987-01-01

    A low cost methodology to produce images of internal sick organs by radioisotopic intake, is presented. Dosimetries of thermoluminescent material and Teflon (ratio:50%) in bidimensional matrix shape are used with a Pb collimator. This collimator-bidimensional matrix system was tested ''in vivo'' and in thyroid phantoms using 99m Tc. A comparative evaluation between this method and the scintigraphy one is presented. (M.A.C.) [pt

  18. Development of a system for acquiring, reconstructing, and visualizing three-dimensional ultrasonic angiograms

    Science.gov (United States)

    Edwards, Warren S.; Ritchie, Cameron J.; Kim, Yongmin; Mack, Laurence A.

    1995-04-01

    We have developed a three-dimensional (3D) imaging system using power Doppler (PD) ultrasound (US). This system can be used for visualizing and analyzing the vascular anatomy of parenchymal organs. To create the 3D PD images, we acquired a series of two-dimensional PD images from a commercial US scanner and recorded the position and orientation of each image using a 3D magnetic position sensor. Three-dimensional volumes were reconstructed using specially designed software and then volume rendered for display. We assessed the feasibility and geometric accuracy of our system with various flow phantoms. The system was then tested on a volunteer by scanning a transplanted kidney. The reconstructed volumes of the flow phantom contained less than 1 mm of geometric distortion and the 3D images of the transplanted kidney depicted the segmental, arcuate, and interlobar vessels.

  19. The introduction of the personnel dosimetry information system in Greece designed as a relational database and the improvements achieved

    International Nuclear Information System (INIS)

    Drikos, G.; Psaromiligos, J.; Geotgiou, G.; Kamenopoulou, V.K.

    1997-01-01

    Dose record keeping is the making and keeping of personnel dose records for radiation workers. It is an essential part of the process of monitoring the exposure of individuals to radiation and shares in the same objectives. The dose record keeping is becoming more and more critical because of the importance of statistical analysis and epidemiological studies in radiation protection, and of the increasing cooperation and exchange of personnel between countries.The GAEC's personnel dosimetry laboratory assures the personnel dosimetry all over the country and keeps the official central dose record.The personnel dosimetry information system had been established in an electronic form on 1989 in Cobol language. Since then appeared various arguments that imposed the change of the data base used. Some of them are: 1. There was no distinction between establishments and their laboratories. 2. The workers did not have a unique code number. consequently, the total dose of a person working in more than one place could not't be estimated. The workers were directly related to their workplace, so if somebody changed his working place he was treated as a new entry, resulting an overestimation of the number of monitored workers introducing an source of errors in the collective and average dose calculations. 3. With the increasing applications of the ionising radiations many types of dosemeters became indispensable e.g. for beta and gamma, for neutrons and for the extremities. Also, the new category of outside workers appeared requesting a special treatment. All these distinctions were not achievable with the previous system. 4. Last years appeared an increasing, interesting in statistical analysis of the personal doses. A program written in Cobol does not't offer many possibilities and has no flexibility for such analysis. The new information system has been rebuilt under the design of a relational database with more possibilities and more flexibility. (authors)

  20. Instrumentation in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Julius, H.W.

    1986-01-01

    In the performance of a thermoluminescence dosimetry (TLD) system the equipment plays an important role. Crucial parameters of instrumentation in TLD are discussed in some detail. A review is given of equipment available on the market today - with some emphasis on automation - which is partly based on information from industry and others involved in research and development. (author)

  1. Identification of Systemic Acquired Resistance–Related Volatile Organic Compounds and their Role in Plant Immunity

    OpenAIRE

    Bichlmeier, Marlies

    2017-01-01

    Systemic acquired resistance (SAR) is an inducible immune response that depends on ENHANCED DISEASE SUSCEPTIBILITY1 (EDS1), which is essential for SAR signalling. In contrast to SAR, local resistance remains intact in Arabidopsis (Arabidopsis thaliana) eds1-2 mutant plants in response to Pseudomonas syringae delivering the effector protein AvrRpm1. I utilized the SAR-specific phenotype of the eds1-2 mutant to identify volatile organic compounds (VOCs) related to SAR. To this end, SAR was indu...

  2. 12 CFR 617.7615 - What should the System institution do when it decides to lease acquired agricultural real estate?

    Science.gov (United States)

    2010-01-01

    ... decides to lease acquired agricultural real estate? 617.7615 Section 617.7615 Banks and Banking FARM... the System institution do when it decides to lease acquired agricultural real estate? (a) Notify the... real estate at a rate equivalent to the appraised rental value of the property. (1) Within 15 days...

  3. Environmental dosimetry

    International Nuclear Information System (INIS)

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  4. The photon energy dependence of the alanine/EPR dosimetry system, an experimental investigation

    International Nuclear Information System (INIS)

    Bergstrand, E.S.; Hole, E.O.; Shortt, K.R.; Ross, C.K.

    2002-01-01

    The energy dependence of a dosimetry system based on electron paramagnetic resonance (EPR) spectroscopy of alanine has been studied to determine its suitability for use in dose verification for radiotherapy. A few experiments with high-energy photon irradiation of alanine have been reported in the literature. However, the reported results disagree whether the ratio of dose in alanine to dose in water is independent of the radiation energy or whether there is a small dependence for photon energies of relevance to radiotherapy. The concentration of free radicals in alanine is proportional to the absorbed dose in alanine over a wide dose range covering three decades. The relative number of radicals may be determined by examining the EPR spectrum, and hence it is possible to determine the dose with a system that has been calibrated using a known dose of 60 Co radiation. In the present work, irradiations of alanine dosimeters were performed at the National Research Council (NRC), in Ottawa, Canada. The radiation qualities investigated were 10, 20 and 30 MV x-rays using the NRC linac. For each radiation quality, 30 dosimeters were irradiated in a water phantom with a level of absorbed dose to water ranging from 10 to 50 Gy. For reference purposes, irradiations using the NRC 60 Co source were performed on more or less the same day as the irradiations at each specific linac quality. In all beams, the dose to water was measured using a graphite-walled NE2571 ionisation chamber that was originally calibrated by comparison with a sealed-water calorimeter. The alanine dosimeters were evaluated at the EPR laboratory at the University of Oslo, Norway, using an X-band Bruker ESP300E spectrometer with a rectangular double resonator. One of the resonators contained a Mn 2+ /MgO sample that was read after each dosimeter reading, in order to provide independence from short-term sensitivity fluctuations in the spectrometer. All dosimeters irradiated at one specific linac quality were

  5. Direct ion storage dosimetry systems for photon, beta and neutron radiation with instant readout capabilities

    International Nuclear Information System (INIS)

    Wernli, C.; Kahilainen, J.

    2001-01-01

    The direct ion storage (DIS) dosemeter is a new type of electronic dosemeter from which the dose information for both H p (10) and H p (0.07) can be obtained instantly at the workplace by using an electronic reader unit. The number of readouts is unlimited and the stored information is not affected by the readout procedure. The accumulated dose can also be electronically reset by authorised personnel. The DIS dosemeter represents a potential alternative for replacing the existing film and thermoluminescence dosemeters (TLDs) used in occupational monitoring due to its ease of use and low operating costs. The standard version for normal photon and beta dosimetry, as well as a developmental version for neutron dosimetry, have been characterised in several field studies. Two new small size variations are also introduced including a contactless readout device and a militarised version optimised for field use. (author)

  6. Mono- and Digalactosyldiacylglycerol Lipids Function Nonredundantly to Regulate Systemic Acquired Resistance in Plants

    Directory of Open Access Journals (Sweden)

    Qing-ming Gao

    2014-12-01

    Full Text Available Summary: The plant galactolipids monogalactosyldiacylglycerol (MGDG and digalactosyldiacylglycerol (DGDG have been linked to the anti-inflammatory and cancer benefits of a green leafy vegetable diet in humans due to their ability to regulate the levels of free radicals like nitric oxide (NO. Here, we show that DGDG contributes to plant NO as well as salicylic acid biosynthesis and is required for the induction of systemic acquired resistance (SAR. In contrast, MGDG regulates the biosynthesis of the SAR signals azelaic acid (AzA and glycerol-3-phosphate (G3P that function downstream of NO. Interestingly, DGDG is also required for AzA-induced SAR, but MGDG is not. Notably, transgenic expression of a bacterial glucosyltransferase is unable to restore SAR in dgd1 plants even though it does rescue their morphological and fatty acid phenotypes. These results suggest that MGDG and DGDG are required at distinct steps and function exclusively in their individual roles during the induction of SAR. : The galactolipids monogalactosyldiacylglycerol (MGDG and digalactosyldiacylglycerol (DGDG constitute ∼80% of total membrane lipids in plants. Gao et al. now show that these galactolipids function nonredundantly to regulate systemic acquired resistance (SAR. Furthermore, they show that the terminal galactose on the α-galactose-β-galactose head group of DGDG is critical for SAR.

  7. Mammalian spermatogenesis as a new system for biologic dosimetry of ionizing irradiation

    International Nuclear Information System (INIS)

    Hacker, U.; Schumann, J.; Goehde, W.

    1982-01-01

    The radiation induced reduction of the number of DNA synthesizing cells (spermatogonia) is described using the fast-working flow cytophotometer. Since there is no shoulder in the initial part of the dose response curve this model of biologic dosimetry is very sensitive. The D 50 value is 0.25 Gy; a radiation exposure of only 0.1 Gy can be detected. (Auth.)

  8. Mammalian spermatogenesis as a new system for biologic dosimetry of ionizing irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, U; Schumann, J; Goehde, W [Muenster Univ. (Germany, F.R.). Radiologische Klinik

    1982-01-01

    The radiation induced reduction of the number of DNA synthesizing cells (spermatogonia) is described using the fast-working flow cytophotometer. Since there is no shoulder in the initial part of the dose response curve this model of biologic dosimetry is very sensitive. The D/sub 50/ value is 0.25 Gy; a radiation exposure of only 0.1 Gy can be detected.

  9. SYSTEM OF EXERCISES FOR ACQUIRING FOREIGN LANGUAGE MEDIA COMPETENCE BY FUTURE JOURNALISTS

    Directory of Open Access Journals (Sweden)

    Анна Палієнко

    2015-05-01

    Full Text Available The article propounds a communicative and cognitive methodological framework of developing an foreign language media competence of the students majoring in journalism. The media competence as an integrative quality is defined and its main constituents are characterized. The definition of a media text as a specialized speech meadi product is specificated. The role of practical operations in acquiring media competence are inicated. They are revealed while accomplishing cognitive and communicative tasks posed in relevant exercises. The appropriate requirements to these exercises are examined and its correlates are exposed.  Exercises included in the system are explored, justified and illustrated with examples. It is established that the designed system of exercises comprises cognitive and communicative exercises of receptive, reproductive and productive character. Congruous mental operations implemented in such exercises and relevant principles of processing media information are specified.

  10. Analysis of quality control tests done by the Canadian power utilities on their external dosimetry systems (June 1988 to May 1993)

    International Nuclear Information System (INIS)

    Butt, K.A.; Poirier, G.S.

    1995-09-01

    The Canadian nuclear power utilities, Hydro-Quebec, New Brunswick Electric Power Commission and Ontario Hydro, use thermoluminescent dosimetry systems to perform their own external beta/gamma dosimetry. In order to help ensure that these systems perform satisfactorily, they are subjected to routine quality control testing by their parent organizations. The test results for the period of June 1988 to May 1993 have been analyzed, at the Atomic Energy Control Board (AECB), using the pass criterion which was originally agreed upon the organizations involved and which is described in section 2.3 of this document. The present analysis offers an indication of the performance of the different sites which operate such a service. Comparisons are made each site's performance during the period June 1985 to May 1988 which has been summarized previously (INFO--0301). Finally, recommendations are made in the hope that they will help the organizations in refining their dosimetry. (author) 1 ref., 7 tabs

  11. Analysis of quality control tests done by the Canadian power utilities on their external dosimetry systems (June 1985 to May 1988)

    International Nuclear Information System (INIS)

    Poirier, G.S.

    1989-04-01

    The Canadian nuclear power utilities, Hydro Quebec, New Brunswick Electric Power Commission and Ontario Hydro, use thermoluminescent dosimetry systems to perform their own external beta/gamma dosimetry. In order to help ensure that these systems perform satisfactorily, they are subjected to routine quality control testing by their parent organizations. The test results for the period of June 1985 to May 1988 have been analyzed, at the AECB, using the pass criterion which was originally agreed upon by the organizations involved. The present analysis offers a comparison of the performance of the different sites which operate such a service. Finally, recommendations are made in the hope that they will help the organizations in refining their dosimetry

  12. DRDC Ottawa Participation in the SILENE Accident Dosimetry Intercomparison Exercise. June 10-21, 2002

    National Research Council Canada - National Science Library

    Prud'homme-Lalonde, L

    2002-01-01

    .... The SILENE International Accident Dosimetry Intercomparison Exercise at Valduc, France in June 2002 coincided with DRDC Ottawa work designed to refine its proposed criticality dosimetry system...

  13. Involvement of ethylene in lesion development and systemic acquired resistance in tobacco during the hypersensitive reaction to tobacco mosaic virus

    NARCIS (Netherlands)

    Knoester, M.; Linthorst, H.J.M.; Bol, J.F.; Loon, L.C. van

    2001-01-01

    Different approaches were taken to investigate the significance of ethylene in lesion development and systemic acquired resistance (SAR) in tobacco (Nicotiana tabacum) reacting hypersensitively to tobacco mosaic virus (TMV). Gaseous ethylene, the ethylene precursor 1-aminocyclopropane-1-carboxylic

  14. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  15. Hematological dosimetry

    International Nuclear Information System (INIS)

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  16. Foetal dosimetry--is the ICRP dosimetric system for humans now complete?

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Steve [Westlakes Research Institute, Cumbria (United Kingdom)

    2002-03-01

    . Nonetheless, calculation of foetal doses as part of a radiological assessment would have been seen as something quite exceptional and not attempted by the average radiation protection practitioner. The recent release of ICRP Publication 88, concisely summarised in this issue by John Stather et al, will change this situation. The new data permit the publication of doses to the embryo and foetus for intakes of radionuclides by the mother both during pregnancy and prior to conception. Selected radioisotopes of 31 elements are covered. A number of intake scenarios are covered including acute intakes at a number of times prior to conception and during pregnancy, constant chronic intakes for one and five years prior to conception, and constant chronic intakes during pregnancy. This report represents the culmination of a major scientific effort by the individuals and institutions involved in Committee 2's Task Group on Internal Dosimetry, on which those involved should be congratulated. In order to calculate dose coefficients for the foetus, the Task Group has needed to establish models for the transfer of radionuclides from maternal circulation to the developing foetus and for the distribution of radionuclides between its tissues and organs; also, a time-dependent model of foetal geometry to permit the calculation of specific effective energies for the necessary source target combinations. As it stands, the report provides a comprehensive basis from which practitioners can calculate foetal doses as part of any radiological assessment, in both occupational and environmental radiation protection settings. A CD-ROM, expected to be available later this year, will make the data more accessible and permit greater flexibility in the calculations. ICRP-88 certainly fills the remaining major gap in the pre-existing system and, to that extent, coverage for humans is now essentially complete. However, many questions remain about the way in which the results of calculations using the new

  17. The spatiotemporal system dynamics of acquired resistance in an engineered microecology.

    Science.gov (United States)

    Datla, Udaya Sree; Mather, William H; Chen, Sheng; Shoultz, Isaac W; Täuber, Uwe C; Jones, Caroline N; Butzin, Nicholas C

    2017-11-22

    Great strides have been made in the understanding of complex networks; however, our understanding of natural microecologies is limited. Modelling of complex natural ecological systems has allowed for new findings, but these models typically ignore the constant evolution of species. Due to the complexity of natural systems, unanticipated interactions may lead to erroneous conclusions concerning the role of specific molecular components. To address this, we use a synthetic system to understand the spatiotemporal dynamics of growth and to study acquired resistance in vivo. Our system differs from earlier synthetic systems in that it focuses on the evolution of a microecology from a killer-prey relationship to coexistence using two different non-motile Escherichia coli strains. Using empirical data, we developed the first ecological model emphasising the concept of the constant evolution of species, where the survival of the prey species is dependent on location (distance from the killer) or the evolution of resistance. Our simple model, when expanded to complex microecological association studies under varied spatial and nutrient backgrounds may help to understand the complex relationships between multiple species in intricate natural ecological networks. This type of microecological study has become increasingly important, especially with the emergence of antibiotic-resistant pathogens.

  18. Design, development and commercialization of ISOCAD (Integrated System of Computer Aided Dosimetry) for gamma irradiators

    International Nuclear Information System (INIS)

    Shrivastava, Amit; Srivastava, Navneet; Kohli, A.K.; Mishra, Vinay Kumar; Singh, Ramnik; Sinha, A.K.

    2014-01-01

    ISOMED facility is the indomitable architect of radiation sterilization era in the country providing the contract radiation processing services for the terminal sterilization of the healthcare products from the healthcare sector. ISOMED has acquired the international standards viz.ISO 9001, ISO 22000, ISO 13485, ISO 11137, OHSAS 18001, ISO 14001 that supplemented by European Union - GMP certification from MHRA - UK. One of the core focuses of these standards is the control of measuring and monitoring instruments with impeccable traceability features with respect to the quality critical processing data. The gamma radiation sterilisation process involves delivery of minimum 25 kGy of radiation dose to the healthcare products which is measured by internationally acclaimed Cerric Cerric Potentiometric Dose Measurement Systems (CCPDMs). As the current variant of this system had extensive involvement of manual interventions, a novel, bar code based computerized application package called ISOCAD, incorporating portable risk free snapping tool for the dosimeter ampules has been synergistically developed by BRIT/BARC for the Cerric Cerrous Potentiometric Dose Measurement System for Gamma Irradiators. ISOCAD has been successfully operating in ISOMED and the techno commercial viability has been convincingly demonstrated to the operators of the gamma irradiators from the country as well as abroad. ISOCAD is now available as one of the commercial product packages from BRIT. (author)

  19. Development and initial characterization of a nuclear magnetic resonance dosimetry system

    International Nuclear Information System (INIS)

    Thomasson, D.M.

    1990-01-01

    A novel high dose radiation dosimeter was developed employing NMR spectroscopic quantitation of the radiolytic products of methanol. Chemical shifts of product resonances relative to the solvent allow quantification using NMR techniques. Due to expected dynamic range limitations of NMR instrumentation, deuterated methanol is used with a presaturation suppression sequence to reduce the solvent proton signals. Methanol's 13 C-coupled proton resonances is used as an internal reference to normalize product signals otherwise subject to spectrometer variability. Data on reproducibility, dose response, and temporal stability were acquired. System reproducibility for a sample at 1 kGy is ∼10%. The dose response is linear in the range between 200 Gy and 50 kGy. No significant signal degradation was observed during a six month period. Advantages of this type dosimeter system include ease of use, large dynamic range, and temporal stability. An additional characteristic of a methanol based system is the LET dependent response in the chemical yields of formaldehyde and ethylene glycol. 70 refs., 15 figs., 9 tabs

  20. Acquired partial lipodystrophy and C3 glomerulopathy: Dysregulation of the complement system as a common mechanism

    Directory of Open Access Journals (Sweden)

    Fernando Corvillo

    2018-05-01

    Full Text Available The activation of the alternative pathway of the complement is involved in the development of several renal diseases, such as atypical haemolytic uraemic syndrome and C3 glomerulopathy. In C3 glomerulopathy, a high percentage of patients have circulating levels of the autoantibody called C3NeF, which causes systemic dysregulation of the complement system. In some cases, the presence of this antibody has been related with abnormalities of adipose tissue, causing acquired partial lipodystrophy (Barraquer–Simons syndrome. Acquired partial lipodystrophy is an extremely rare disorder affecting the distribution of subcutaneous adipose tissue and that mainly onsets during childhood. These patients, in addition to possibly presenting with all the metabolic disorders associated with the adipose tissue defect, present with C3 hypocomplementemia and C3NeF and 25% have developed C3 glomerulopathy. Although it has been known for some time how the dysregulation of the complement system affects the kidneys, it remains unknown how it exactly affects adipose tissue; nevertheless, the relationship is quite clear. In this paper, we describe the connection between the complement system with the biology of the adipose tissue and its pathogenesis reflected from acquired partial lipodystrophy. Resumen: La activación de la vía alternativa del complemento interviene en el desarrollo de varias enfermedades renales, como el síndrome hemolítico urémico atípico o la glomerulopatía C3. En esta última enfermedad un elevado porcentaje de los pacientes presentan niveles circulantes de un autoanticuerpo denominado C3NeF, causante de la desregulación del complemento a nivel sistémico. En ciertos casos, la presencia de este anticuerpo se asocia con alteraciones en el tejido adiposo, causando lipodistrofia parcial adquirida (síndrome de Barraquer-Simons, una enfermedad ultra-rara que afecta a la distribución del tejido adiposo subcutáneo y que comienza principalmente

  1. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Torii, Yoshiya [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  2. COMPARISON OF RESPONSE OF PASSIVE DOSIMETRY SYSTEMS IN SCANNING PROTON RADIOTHERAPY-A STUDY USING PAEDIATRIC ANTHROPOMORPHIC PHANTOMS.

    Science.gov (United States)

    Kneževic, Ž; Ambrozova, I; Domingo, C; De Saint-Hubert, M; Majer, M; Martínez-Rovira, I; Miljanic, S; Mojzeszek, N; Porwol, P; Ploc, O; Romero-Expósito, M; Stolarczyk, L; Trinkl, S; Harrison, R M; Olko, P

    2017-11-18

    Proton beam therapy has advantages in comparison to conventional photon radiotherapy due to the physical properties of proton beams (e.g. sharp distal fall off, adjustable range and modulation). In proton therapy, there is the possibility of sparing healthy tissue close to the target volume. This is especially important when tumours are located next to critical organs and while treating cancer in paediatric patients. On the other hand, the interactions of protons with matter result in the production of secondary radiation, mostly neutrons and gamma radiation, which deposit their energy at a distance from the target. The aim of this study was to compare the response of different passive dosimetry systems in mixed radiation field induced by proton pencil beam inside anthropomorphic phantoms representing 5 and 10 years old children. Doses were measured in different organs with thermoluminescent (MTS-7, MTS-6 and MCP-N), radiophotoluminescent (GD-352 M and GD-302M), bubble and poly-allyl-diglycol carbonate (PADC) track detectors. Results show that RPL detectors are the less sensitive for neutrons than LiF TLDs and can be applied for in-phantom dosimetry of gamma component. Neutron doses determined using track detectors, bubble detectors and pairs of MTS-7/MTS-6 are consistent within the uncertainty range. This is the first study dealing with measurements on child anthropomorphic phantoms irradiated by a pencil scanning beam technique. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Characterization of fuel distribution in the Three Mile Island Unit 2 (TMI-2) reactor system by neutron and gamma-ray dosimetry

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Ruddy, F.H.; Preston, C.C.; McNeece, J.P.; Kaiser, B.J.; McElroy, W.N.

    1984-01-01

    Neutron and gamma-ray dosimetry are being used for nondestructive assessment of the fuel distribution throughout the Three Mile Island Unit 2 (TMI-2) reactor core region and primary cooling system. The fuel content of TMI-2 makeup and purification Demineralizer A has been quantified with Si(Li) continuous gamma-ray spectrometry and solid-state track recorder (SSTR) neutron dosimetry. For fuel distribution characterization in the core region, results from SSTR neutron dosimetry exposures in the TMI-2 reactor cavity are presented. These SSTR results are consistent with the presence of a significant amount of fuel debris, equivalent to several fuel assemblies or more, lying at the bottom of the reactor vessel. (Auth.)

  4. Dosimetry control for radiation processing - basic requirements and standards

    International Nuclear Information System (INIS)

    Ivanova, M.; Tsrunchev, Ts.

    2004-01-01

    A brief review of the basic international codes and standards for dosimetry control for radiation processing (high doses dosimetry), setting up a dosimetry control for radiation processing and metrology control of the dosimetry system is made. The present state of dosimetry control for food processing and the Bulgarian long experience in food irradiation (three irradiation facilities are operational at these moment) are presented. The absence of neither national standard for high doses nor accredited laboratory for calibration and audit of radiation processing dosimetry systems is also discussed

  5. Knowledge acquired during the implementation of the BWR emergency procedures tracking system

    International Nuclear Information System (INIS)

    Petrick, W.; Sun, B.K.H.; Naser, J.

    1992-01-01

    An Emergency Operating Procedures Tracking System (EOPTS) has been developed, installed and tested at Taiwan Power Company's Kuo Sheng BWR plant. The EOPTS is based on artificial intelligence methodologies to meet project objectives that could not be met using conventional techniques. The plant EOP's were encoded into a rule-based expert system developed specifically for this application. The EOPTS executes within the GE/ERFIS system to provide close integration with the plant SPDS. The initial EOPTS was implemented in the Kuo Sheng simulator to allow quantitative crew evaluations of the system. Statistical analysis techniques were used to demonstrate that the crews using the EOPTS showed faster responses, fewer errors, and more consistent actions than the crews using the EOP flowcharts. The knowledge acquired during the EOPTS project resulted in improved understanding of related areas such as the EPG'S, plant EOPS, man-machine interfaces, and simulator models for severe transients. These experiences will be used in the future to transfer the technology to US utilities with the objective to improve operator training of the plant EOPs during severe multiple failure transients. To this end, EPRI has developed a technology assessment package that is available to interested utilities. 9 refs., 1 fig

  6. Participation of IRD/CNEN-Br in International Intercomparison of Criticality Accident Dosimetry Systems at Silene reactor, France

    International Nuclear Information System (INIS)

    Mauricio, Claudia Lucia P.; Fonseca, Evaldo S. da

    1996-01-01

    IRD has participated in an International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE reactor, France on June 1993. The dosemeters were irradiated on phantoms and free in air, in bare and lead shield reactor pulses, simulating different irradiation fields that can be found in criticality accidents. Comparing with the reference measurements, the calculated mean neutron kerma found by IRD was only 2% greater for lead shield and 14% greater for bare reactor. For gamma absorbed dose, the differences were, respectively + 22% and -9% for the dosemeters free in air and -19% and -9% for dosemeters on phantoms. IRD results are closer to the real values than the mean values measured by the participants. IRD results show a good performance if its simple criticality accident system. (author)

  7. The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.

    Science.gov (United States)

    Gualdrini, G; Bedogni, R; Fantuzzi, E; Mariotti, F

    2004-01-01

    The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry Systems' (Silène reactor, IRSN-CEA-Valduc June 2002). The evaluation of the neutron spectra and the neutron dosimetric quantities relies on activation detectors and on unfolding algorithms. Thermoluminescent detectors are employed for the gamma dose measurement. The work is aimed at accurately characterising the measurement system and, at the same time, testing the algorithms. Useful spectral information were included, based on Monte Carlo simulations, to take into account the potential accident scenarios of practical interest. All along this exercise intercomparison a particular attention was devoted to the 'traceability' of all the experimental and computational parameters and therefore, aimed at an easy treatment by the user.

  8. Some recent multi-frequency electron paramagnetic resonance results on systems relevant for dosimetry and dating.

    Science.gov (United States)

    Callens, F; Vanhaelewyn, G; Matthys, P

    2002-04-01

    Electron Paramagnetic Resonance (EPR) applications like e.g. EPR dosimetry and dating, are usually performed at X-band frequencies because of practical reasons (cost, sample size, etc.). However, it is increasingly recognized that the radiation-induced EPR signals are strongly composite, what might affect dose/age estimates. A few recent examples from both the dosimetry and dating field, illustrating the problems, will be presented. The involved spectra are mainly due to carbonate-derived radicals (CO2-, CO3(3-), etc.). Measurements at higher microwave frequencies are often recommended to improve the insight into the spectra and/or the practical signal quantification. Recent results at Q- and W-band frequencies will show that a multi-frequency approach indeed opens many interesting perspectives in this field but also that each frequency may have specific (dis)advantages depending on the EPR probe and application involved. The discussion will concern carbonate-containing apatite single crystals, shells, modern and fossil tooth enamel.

  9. Methyl salicylate is a critical mobile signal for plant systemic acquired resistance.

    Science.gov (United States)

    Park, Sang-Wook; Kaimoyo, Evans; Kumar, Dhirendra; Mosher, Stephen; Klessig, Daniel F

    2007-10-05

    In plants, the mobile signal for systemic acquired resistance (SAR), an organism-wide state of enhanced defense to subsequent infections, has been elusive. By stimulating immune responses in mosaic tobacco plants created by grafting different genetic backgrounds, we showed that the methyl salicylate (MeSA) esterase activity of salicylic acid-binding protein 2 (SABP2), which converts MeSA into salicylic acid (SA), is required for SAR signal perception in systemic tissue, the tissue that does not receive the primary (initial) infection. Moreover, in plants expressing mutant SABP2 with unregulated MeSA esterase activity in SAR signal-generating, primary infected leaves, SAR was compromised and the associated increase in MeSA levels was suppressed in primary infected leaves, their phloem exudates, and systemic leaves. SAR was also blocked when SA methyl transferase (which converts SA to MeSA) was silenced in primary infected leaves, and MeSA treatment of lower leaves induced SAR in upper untreated leaves. Therefore, we conclude that MeSA is a SAR signal in tobacco.

  10. An automatic system to search, acquire, and analyse chromosomal aberrations obtained using FISH technique

    International Nuclear Information System (INIS)

    Esposito, R.D.

    2003-01-01

    Full text: Chromosomal aberrations (CA) analysis in peripheral blood lymphocytes is useful both in prenatal diagnoses and cancer cytogenetics, as well as in toxicology to determine the biologically significant dose of specific, both physical and chemical, genotoxic agents to which an individual is exposed. A useful cytogenetic technique for CAs analysis is Fluorescence-in-situ-Hybridization (FISH) which simplifies the automatic Identification and characterisation of aberrations, allowing the visualisation of chromosomes as bright signals on a dark background, and a fast analysis of stable aberrations, which are particularly interesting for late effects. The main limitation of CA analysis is the rarity with which these events occur, and therefore the time necessary to single out a statistically significant number of aberrant cells. In order to address this problem, a prototype system, capable of automatically searching, acquiring, and recognising chromosomal images of samples prepared using FISH, has been developed. The system is able to score large number of samples in a reasonable time using predefined search criteria. The system is based on the appropriately implemented and characterised automatic metaphase finder Metafer4 (MetaSystems), coupled with a specific module for the acquisition of high magnification metaphase images with any combination of fluorescence filters. These images are then analysed and classified using our software. The prototype is currently capable of separating normal metaphase images from presumed aberrant ones. This system is currently in use in our laboratories both by ourselves and by other researchers not involved in its development, in order to carry out analyses of CAs induced by ionising radiation. The prototype allows simple acquisition and management of large quantities of images and makes it possible to carry out methodological studies -such as the comparison of results obtained by different operators- as well as increasing the

  11. The dosimetry programme of the IAEA

    International Nuclear Information System (INIS)

    1987-01-01

    Describes the activities of the IAEA's Dosimetry Laboratory which provides calibration and comparison services for secondary standard dosimetry laboratories (SSDLs) of Member States. In addition, a joint IAEA/WHO postal dosimetry service has been established for radiotherapy centers. The International Measurement System and the calibration ''chain'' from measurement standard instruments of the International Bureau of Weights and Measurements (BIPM) through the primary and secondary standards to the dosimeters of the users are presented as well

  12. Predicting hospital-acquired infections by scoring system with simple parameters.

    Directory of Open Access Journals (Sweden)

    Ying-Jui Chang

    Full Text Available BACKGROUND: Hospital-acquired infections (HAI are associated with increased attributable morbidity, mortality, prolonged hospitalization, and economic costs. A simple, reliable prediction model for HAI has great clinical relevance. The objective of this study is to develop a scoring system to predict HAI that was derived from Logistic Regression (LR and validated by Artificial Neural Networks (ANN simultaneously. METHODOLOGY/PRINCIPAL FINDINGS: A total of 476 patients from all the 806 HAI inpatients were included for the study between 2004 and 2005. A sample of 1,376 non-HAI inpatients was randomly drawn from all the admitted patients in the same period of time as the control group. External validation of 2,500 patients was abstracted from another academic teaching center. Sixteen variables were extracted from the Electronic Health Records (EHR and fed into ANN and LR models. With stepwise selection, the following seven variables were identified by LR models as statistically significant: Foley catheterization, central venous catheterization, arterial line, nasogastric tube, hemodialysis, stress ulcer prophylaxes and systemic glucocorticosteroids. Both ANN and LR models displayed excellent discrimination (area under the receiver operating characteristic curve [AUC]: 0.964 versus 0.969, p = 0.507 to identify infection in internal validation. During external validation, high AUC was obtained from both models (AUC: 0.850 versus 0.870, p = 0.447. The scoring system also performed extremely well in the internal (AUC: 0.965 and external (AUC: 0.871 validations. CONCLUSIONS: We developed a scoring system to predict HAI with simple parameters validated with ANN and LR models. Armed with this scoring system, infectious disease specialists can more efficiently identify patients at high risk for HAI during hospitalization. Further, using parameters either by observation of medical devices used or data obtained from EHR also provided good prediction

  13. Interconnection between flowering time control and activation of systemic acquired resistance

    Directory of Open Access Journals (Sweden)

    Zeeshan Zahoor Banday

    2015-03-01

    Full Text Available The ability to avoid or neutralize pathogens is inherent to all higher organisms including plants. Plants recognize pathogens through receptors, and mount resistance against the intruders, with the help of well-elaborated defense arsenal. In response to some local infections, plants develop systemic acquired resistance (SAR, which provides heightened resistance during subsequent infections. Infected tissues generate mobile signalling molecules that travel to the systemic tissues, where they epigenetically modify expression of a set of genes to initiate the manifestation of SAR in distant tissues. Immune responses are largely regulated at transcriptional level. Flowering is a developmental transition that occurs as a result of the coordinated action of large numbers of transcription factors that respond to intrinsic signals and environmental conditions. The plant hormone salicylic acid (SA which is required for SAR activation positively regulates flowering. Certain components of chromatin remodelling complexes that are recruited for suppression of precocious flowering are also involved in suppression of SAR in healthy plants. FLOWERING LOCUS D (FLD, a putative histone demethylase positively regulates SAR manifestation and flowering transition in Arabidopsis. Similarly, incorporation of histone variant H2A.Z in nucleosomes mediated by PHOTOPERIOD-INDEPENDENT EARLY FLOWERING 1 (PIE1, an orthologue of yeast chromatin remodelling complex SWR1, concomitantly influences SAR and flowering time. SUMO conjugation and deconjugation mechanisms also similarly affect SAR and flowering in an SA-dependent manner. The evidences suggest a common underlying regulatory mechanism for activation of SAR and flowering in plants.

  14. A preliminary study on thermoluminescence of AMOLED glass from mobile phones for retrospective dosimetry

    International Nuclear Information System (INIS)

    Kim, Hyoungtaek; Lee, Jungil; Chang, Insu; Lee, Seung Kyu; Kim, Min Chae; Park, Sang Won; Kim, Jang-Lyul; Kim, Bong-Hwan; Yu, Hyungjoon; Kim, Ah-reum

    2017-01-01

    Since mobile phones are always carried by individuals, the retrospective dosimetry using thermoluminescence (TL) and optically stimulated luminescence (OSL) characteristics of elements in mobile phone is intensively developing nowadays due to its advantages over conventional biological dosimetry techniques. Using a TL and OSL method on resistors and inductors in a mobile phone, a low background dose (zero dose) about tens of mGy is acquired in previous study. Radiation workers have to wear a dosimeter to assess individual exposure during their works. This monitoring system facilitate a fast medical treatment for highly exposed workers in case of a radiation accident. In the event of large-scale radiation accidents, where most of the subjects are ordinary people, it is difficult to evaluate the individual dose due to the absence of dosimeters. A technique for dose evaluation using a radiation dependency of various materials in the absence of a dosimeter is called retrospective dosimetry.

  15. Acquired activated protein C resistance is associated with lupus anticoagulants and thrombotic events in pediatric patients with systemic lupus erythematosus.

    Science.gov (United States)

    Male, C; Mitchell, L; Julian, J; Vegh, P; Joshua, P; Adams, M; David, M; Andrew, M E

    2001-02-15

    Acquired activated protein C resistance (APCR) has been hypothesized as a possible mechanism by which antiphospholipid antibodies (APLAs) cause thrombotic events (TEs). However, available evidence for an association of acquired APCR with APLAs is limited. More importantly, an association of acquired APCR with TEs has not been demonstrated. The objective of the study was to determine, in pediatric patients with systemic lupus erythematosus (SLE), whether (1) acquired APCR is associated with the presence of APLAs, (2) APCR is associated with TEs, and (3) there is an interaction between APCR and APLAs in association with TEs. A cross-sectional cohort study of 59 consecutive, nonselected children with SLE was conducted. Primary clinical outcomes were symptomatic TEs, confirmed by objective radiographic tests. Laboratory testing included lupus anticoagulants (LAs), anticardiolipin antibodies (ACLAs), APC ratio, protein S, protein C, and factor V Leiden. The results revealed that TEs occurred in 10 (17%) of 59 patients. Acquired APCR was present in 18 (31%) of 58 patients. Acquired APCR was significantly associated with the presence of LAs but not ACLAs. Acquired APCR was also significantly associated with TEs. There was significant interaction between APCR and LAs in the association with TEs. Presence of both APCR and LAs was associated with the highest risk of a TE. Protein S and protein C concentrations were not associated with the presence of APLAs, APCR, or TEs. Presence of acquired APCR is a marker identifying LA-positive patients at high risk of TEs. Acquired APCR may reflect interference of LAs with the protein C pathway that may represent a mechanism of LA-associated TEs. (Blood. 2001;97:844-849)

  16. Neutron Dosimetry

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2001-01-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding

  17. Neutron Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Vanhavere, F

    2001-04-01

    The objective of SCK-CEN's R and D programme on neutron dosimetry is to improve the determination of neutron doses by studying neutron spectra, neutron dosemeters and shielding adaptations. In 2000, R and D focused on the contiued investigation of the bubble detectors type BD-PND and BDT, in particular their sensitivity and temperature dependence; the updating of SCK-CEN's criticality dosemeter, the investigation of the characteristics of new thermoluminescent materials and their use in neutron dosemetry; and the investigation of neutron shielding.

  18. A critical role for Arabidopsis MILDEW RESISTANCE LOCUS O2 in systemic acquired resistance.

    Science.gov (United States)

    Gruner, Katrin; Zeier, Tatyana; Aretz, Christina; Zeier, Jürgen

    2018-04-16

    Members of the MILDEW RESISTANCE LOCUS O (MLO) gene family confer susceptibility to powdery mildews in different plant species, and their existence therefore seems to be disadvantageous for the plant. We recognized that expression of the Arabidopsis MLO2 gene is induced after inoculation with the bacterial pathogen Pseudomonas syringae, promoted by salicylic acid (SA) signaling, and systemically enhanced in the foliage of plants exhibiting systemic acquired resistance (SAR). Importantly, distinct mlo2 mutant lines were unable to systemically increase resistance to bacterial infection after inoculation with P. syringae, indicating that the function of MLO2 is necessary for biologically-induced SAR in Arabidopsis. Our data also suggest that the close homolog MLO6 has a supportive but less critical role in SAR. In contrast to SAR, basal resistance to bacterial infection was not affected in mlo2. Remarkably, SAR-defective mlo2 mutants were still competent in systemically increasing the levels of the SAR-activating metabolites pipecolic acid (Pip) and SA after inoculation, and to enhance SAR-related gene expression in distal plant parts. Furthermore, although MLO2 was not required for SA- or Pip-inducible defense gene expression, it was essential for the proper induction of disease resistance by both SAR signals. We conclude that MLO2 acts as a critical downstream component in the execution of SAR to bacterial infection, being required for the translation of elevated defense responses into disease resistance. Moreover, our data suggest a function for MLO2 in the activation of plant defense priming during a P. syringae challenge. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Acquiring beam data for a flattening-filter free linear accelerator using organic scintillators

    International Nuclear Information System (INIS)

    Beierholm, A.R.; Behrens, C.F.; Hoffmann, L.; Andersen, C.E.

    2013-01-01

    Fibre-coupled organic scintillators have been proven a credible alternative to clinically implemented methods for radiotherapy dosimetry, primarily due to their water equivalence and good spatial resolution. Furthermore, the fast response of the scintillators can be exploited to perform time-resolved dosimetry on a highly detailed level. In this study, we present beam data for a Varian TrueBeam linear accelerator, which is capable of delivering flattening-filter free (FFF 1 ) clinical X-ray beams. The beam data have been acquired using an in-house developed dosimetry system based on fibre-coupled organic scintillators. The presented data exhibit high accuracy and precision when compared with data obtained using commercial dosimetry methods, and agree well with results published in the literature. -- Highlights: •A dosimetry system based on fibre-coupled organic scintillators is presented. •The system is used for radiotherapy beams with and without flattening filter. •Measurements show good agreement with various commercial dosimeters

  20. Experimental verification of internal dosimetry calculations. Annual progress report

    International Nuclear Information System (INIS)

    1980-05-01

    During the past year a dosimetry research program has been established in the School of Nuclear Engineering at the Georgia Institute of Technology. The major objective of this program has been to provide research results upon which a useful internal dosimetry system could be based. The important application of this dosimetry system will be the experimental verification of internal dosimetry calculations such as those published by the MIRD Committee

  1. Advantages and disadvantages of luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Olko, Pawel, E-mail: Pawel.Olko@ifj.edu.p [Institute of Nuclear Physics Polish Academy of Science (IFJ PAN), Krakow (Poland)

    2010-03-15

    Owing to their excellent dosimetric properties, luminescence detectors of ionizing radiation are now extensively applied in individual dosimetry services. The most frequently used personal dosemeters are based on Optically Stimulated Luminescence (OSL), radiophotoluminescence (RPL) or thermoluminescence (TL). Luminescence detectors have also found several applications in clinical dosimetry, especially around new radiation modalities in radiotherapy, such as Intensity Modulated Radiotherapy (IMRT) or ion beam radiotherapy. Requirements of luminescence detectors applied in individual and clinical dosimetry and some recent developments in luminescence of detectors and techniques leading to significant improvements of the functionality and accuracy of dosimetry systems are reviewed and discussed.

  2. Towards a Continuous Biometric System Based on ECG Signals Acquired on the Steering Wheel

    Directory of Open Access Journals (Sweden)

    João Ribeiro Pinto

    2017-09-01

    Full Text Available Electrocardiogram signals acquired through a steering wheel could be the key to seamless, highly comfortable, and continuous human recognition in driving settings. This paper focuses on the enhancement of the unprecedented lesser quality of such signals, through the combination of Savitzky-Golay and moving average filters, followed by outlier detection and removal based on normalised cross-correlation and clustering, which was able to render ensemble heartbeats of significantly higher quality. Discrete Cosine Transform (DCT and Haar transform features were extracted and fed to decision methods based on Support Vector Machines (SVM, k-Nearest Neighbours (kNN, Multilayer Perceptrons (MLP, and Gaussian Mixture Models - Universal Background Models (GMM-UBM classifiers, for both identification and authentication tasks. Additional techniques of user-tuned authentication and past score weighting were also studied. The method’s performance was comparable to some of the best recent state-of-the-art methods (94.9% identification rate (IDR and 2.66% authentication equal error rate (EER, despite lesser results with scarce train data (70.9% IDR and 11.8% EER. It was concluded that the method was suitable for biometric recognition with driving electrocardiogram signals, and could, with future developments, be used on a continuous system in seamless and highly noisy settings.

  3. Towards a Continuous Biometric System Based on ECG Signals Acquired on the Steering Wheel.

    Science.gov (United States)

    Pinto, João Ribeiro; Cardoso, Jaime S; Lourenço, André; Carreiras, Carlos

    2017-09-28

    Electrocardiogram signals acquired through a steering wheel could be the key to seamless, highly comfortable, and continuous human recognition in driving settings. This paper focuses on the enhancement of the unprecedented lesser quality of such signals, through the combination of Savitzky-Golay and moving average filters, followed by outlier detection and removal based on normalised cross-correlation and clustering, which was able to render ensemble heartbeats of significantly higher quality. Discrete Cosine Transform (DCT) and Haar transform features were extracted and fed to decision methods based on Support Vector Machines (SVM), k-Nearest Neighbours (kNN), Multilayer Perceptrons (MLP), and Gaussian Mixture Models - Universal Background Models (GMM-UBM) classifiers, for both identification and authentication tasks. Additional techniques of user-tuned authentication and past score weighting were also studied. The method's performance was comparable to some of the best recent state-of-the-art methods (94.9% identification rate (IDR) and 2.66% authentication equal error rate (EER)), despite lesser results with scarce train data (70.9% IDR and 11.8% EER). It was concluded that the method was suitable for biometric recognition with driving electrocardiogram signals, and could, with future developments, be used on a continuous system in seamless and highly noisy settings.

  4. The burden and epidemiology of community-acquired central nervous system infections: a multinational study.

    Science.gov (United States)

    Erdem, H; Inan, A; Guven, E; Hargreaves, S; Larsen, L; Shehata, G; Pernicova, E; Khan, E; Bastakova, L; Namani, S; Harxhi, A; Roganovic, T; Lakatos, B; Uysal, S; Sipahi, O R; Crisan, A; Miftode, E; Stebel, R; Jegorovic, B; Fehér, Z; Jekkel, C; Pandak, N; Moravveji, A; Yilmaz, H; Khalifa, A; Musabak, U; Yilmaz, S; Jouhar, A; Oztoprak, N; Argemi, X; Baldeyrou, M; Bellaud, G; Moroti, R V; Hasbun, R; Salazar, L; Tekin, R; Canestri, A; Čalkić, L; Praticò, L; Yilmaz-Karadag, F; Santos, L; Pinto, A; Kaptan, F; Bossi, P; Aron, J; Duissenova, A; Shopayeva, G; Utaganov, B; Grgic, S; Ersoz, G; Wu, A K L; Lung, K C; Bruzsa, A; Radic, L B; Kahraman, H; Momen-Heravi, M; Kulzhanova, S; Rigo, F; Konkayeva, M; Smagulova, Z; Tang, T; Chan, P; Ahmetagic, S; Porobic-Jahic, H; Moradi, F; Kaya, S; Cag, Y; Bohr, A; Artuk, C; Celik, I; Amsilli, M; Gul, H C; Cascio, A; Lanzafame, M; Nassar, M

    2017-09-01

    Risk assessment of central nervous system (CNS) infection patients is of key importance in predicting likely pathogens. However, data are lacking on the epidemiology globally. We performed a multicenter study to understand the burden of community-acquired CNS (CA-CNS) infections between 2012 and 2014. A total of 2583 patients with CA-CNS infections were included from 37 referral centers in 20 countries. Of these, 477 (18.5%) patients survived with sequelae and 227 (8.8%) died, and 1879 (72.7%) patients were discharged with complete cure. The most frequent infecting pathogens in this study were Streptococcus pneumoniae (n = 206, 8%) and Mycobacterium tuberculosis (n = 152, 5.9%). Varicella zoster virus and Listeria were other common pathogens in the elderly. Although staphylococci and Listeria resulted in frequent infections in immunocompromised patients, cryptococci were leading pathogens in human immunodeficiency virus (HIV)-positive individuals. Among the patients with any proven etiology, 96 (8.9%) patients presented with clinical features of a chronic CNS disease. Neurosyphilis, neurobrucellosis, neuroborreliosis, and CNS tuberculosis had a predilection to present chronic courses. Listeria monocytogenes, Staphylococcus aureus, M. tuberculosis, and S. pneumoniae were the most fatal forms, while sequelae were significantly higher for herpes simplex virus type 1 (p < 0.05 for all). Tackling the high burden of CNS infections globally can only be achieved with effective pneumococcal immunization and strategies to eliminate tuberculosis, and more must be done to improve diagnostic capacity.

  5. Hanford External Dosimetry Program

    International Nuclear Information System (INIS)

    Fix, J.J.

    1990-10-01

    This document describes the Hanford External Dosimetry Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy (DOE) and its Hanford contractors. Program services include administrating the Hanford personnel dosimeter processing program and ensuring that the related dosimeter data accurately reflect occupational dose received by Hanford personnel or visitors. Specific chapters of this report deal with the following subjects: personnel dosimetry organizations at Hanford and the associated DOE and contractor exposure guidelines; types, characteristics, and procurement of personnel dosimeters used at Hanford; personnel dosimeter identification, acceptance testing, accountability, and exchange; dosimeter processing and data recording practices; standard sources, calibration factors, and calibration processes (including algorithms) used for calibrating Hanford personnel dosimeters; system operating parameters required for assurance of dosimeter processing quality control; special dose evaluation methods applied for individuals under abnormal circumstances (i.e., lost results, etc.); and methods for evaluating personnel doses from nuclear accidents. 1 ref., 14 figs., 5 tabs

  6. Epidemic of medical errors and hospital-acquired infections: systemic and social causes

    National Research Council Canada - National Science Library

    Charney, William

    2012-01-01

    ...) and pharmaceutical errors combined are the second or third leading killer of Americans annually: approximately 300,000 die from a combination of medical errors, hospital acquired infections (HAIs...

  7. Type test of the Rados MTS-N thermoluminescent dosimetry system for individual monitoring of whole body photons in HP (10)

    International Nuclear Information System (INIS)

    Ferreira, M.S.; Silva, E.R. da; Maurício, C.L.P.

    2017-01-01

    The Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ), uses an automatic thermoluminescent dosimetry (TL) system for evaluation of whole body for photons with individual monitors RADOS MTS-N, with TLF detector of LiF: Mg, Ti. The objective of this work was to characterize this system for the evaluation of H P (10) operating magnitude. The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. Performance tests were done for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence and fading. The acceptance requirements used to test system performance have been drawn from national and international documents. The results obtained prove that the system can be used to measure the occupational dose of photons in H P (10)

  8. Personnel neutron dosimetry at Department of Energy facilities

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.; Selby, J.M.; Vallario, E.J.

    1980-08-01

    This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered

  9. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2006-01-01

    The object of this paper is to give a new user some practical information on the use of radiochromic films for medical applications. While various aspects of radiochromic film dosimetry for medical applications have been covered in some detail in several other excellent review articles which have appeared in the last few years [Niroomand-Rad, A., Blackwell, C.R., Coursey, B.M., Gall, K.P., McLaughlin, W.L., Meigooni, A.S., Nath, R., Rodgers, J.E., Soares, C.G., 1998. Radiochromic dosimetry: recommendations of the AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25, 2093-2115; Dempsey, J.F., Low, D.A., Mutic, S., Markman, J., Kirov, A.S., Nussbaum, G.H., Williamson, J.F., 2000. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions. Med. Phys. 27, 2462-2475; Butson, M.J., Yu, P.K.N., Cheung, T., Metcalfe, P., 2003. Radiochromic film for medical radiation dosimetry. Mater. Sci. Eng. R41, 61-120], it is the intent of the present author to present material from a more user-oriented and practical standpoint. That is, how the films work will be stressed much less than how to make the films work well. The strength of radiochromic films is most evident in applications where there is a very high dose gradient and relatively high absorbed dose rates. These conditions are associated with brachytherapy applications, measurement of small fields, and at the edges (penumbra regions) of larger fields

  10. Radiation dosimetry

    International Nuclear Information System (INIS)

    Harper, M.W.; Thomas, B.; Conway, J.

    1977-01-01

    A dosemeter is described that is based on the TSCD principle (thermally stimulated current dosimetry). Basically this involves irradiating a responsive material and then heating it,whereby an electric current is produced. If the material is heated in an electric field the peak value of the thermally stimulated current or alternatively the total charge released by heating, can be related to the radiation dose received. The instrument described utilises a sheet coated with a thermoplastic polymer, such as a poly4-methylpent-l-ene. The polymer should have a softening point not lower than 150 0 C with an electrical resistivity of at least 10 16 chms/cm at 150 0 C. The polymer may also be PTFE. Heating should be in the range 150 0 C to 200 0 C and the electric field in the range 50 to 10,000V/mm. (U.K.)

  11. NH4+ protects tomato plants against Pseudomonas syringae by activation of systemic acquired acclimation.

    Science.gov (United States)

    Fernández-Crespo, Emma; Scalschi, Loredana; Llorens, Eugenio; García-Agustín, Pilar; Camañes, Gemma

    2015-11-01

    NH4 (+) nutrition provokes mild toxicity by enhancing H2O2 accumulation, which acts as a signal activating systemic acquired acclimation (SAA). Until now, induced resistance mechanisms in response to an abiotic stimulus and related to SAA were only reported for exposure to a subsequent abiotic stress. Herein, the first evidence is provided that this acclimation to an abiotic stimulus induces resistance to later pathogen infection, since NH4 (+) nutrition (N-NH4 (+))-induced resistance (NH4 (+)-IR) against Pseudomonas syringae pv tomato DC3000 (Pst) in tomato plants was demonstrated. N-NH4 (+) plants displayed basal H2O2, abscisic acid (ABA), and putrescine (Put) accumulation. H2O2 accumulation acted as a signal to induce ABA-dependent signalling pathways required to prevent NH4 (+) toxicity. This acclimatory event provoked an increase in resistance against later pathogen infection. N-NH4 (+) plants displayed basal stomatal closure produced by H2O2 derived from enhanced CuAO and rboh1 activity that may reduce the entry of bacteria into the mesophyll, diminishing the disease symptoms as well as strongly inducing the oxidative burst upon Pst infection, favouring NH4 (+)-IR. Experiments with inhibitors of Put accumulation and the ABA-deficient mutant flacca demonstrated that Put and ABA downstream signalling pathways are required to complete NH4 (+)-IR. The metabolic profile revealed that infected N-NH4 (+) plants showed greater ferulic acid accumulation compared with control plants. Although classical salicylic acid (SA)-dependent responses against biotrophic pathogens were not found, the important role of Put in the resistance of tomato against Pst was demonstrated. Moreover, this work revealed the cross-talk between abiotic stress acclimation (NH4 (+) nutrition) and resistance to subsequent Pst infection. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  12. [Investigation of bacterial and viral etiology in community acquired central nervous system infections with molecular methods].

    Science.gov (United States)

    Kahraman, Hasip; Tünger, Alper; Şenol, Şebnem; Gazi, Hörü; Avcı, Meltem; Örmen, Bahar; Türker, Nesrin; Atalay, Sabri; Köse, Şükran; Ulusoy, Sercan; Işıkgöz Taşbakan, Meltem; Sipahi, Oğuz Reşat; Yamazhan, Tansu; Gülay, Zeynep; Alp Çavuş, Sema; Pullukçu, Hüsnü

    2017-07-01

    In this multicenter prospective cohort study, it was aimed to evaluate the bacterial and viral etiology in community-acquired central nervous system infections by standart bacteriological culture and multiplex polymerase chain reaction (PCR) methods. Patients hospitalized with central nervous system infections between April 2012 and February 2014 were enrolled in the study. Demographic and clinical information of the patients were collected prospectively. Cerebrospinal fluid (CSF) samples of the patients were examined by standart bacteriological culture methods, bacterial multiplex PCR (Seeplex meningitis-B ACE Detection (Streptococcus pneumoniae, Neisseria meningitidis, Haemophilus influenzae, Listeria monocytogenes, Group B streptococci) and viral multiplex PCR (Seeplex meningitis-V1 ACE Detection kits herpes simplex virus-1 (HSV1), herpes simplex virus-2 (HSV2), varicella zoster virus (VZV), cytomegalovirus (CMV), Epstein Barr virus (EBV) and human herpes virus 6 (HHV6)) (Seeplex meningitis-V2 ACE Detection kit (enteroviruses)). Patients were classified as purulent meningitis, aseptic meningitis and encephalitis according to their clinical, CSF (leukocyte level, predominant cell type, protein and glucose (blood/CSF) levels) and cranial imaging results. Patients who were infected with a pathogen other than the detection of the kit or diagnosed as chronic meningitis and other diseases during the follow up, were excluded from the study. A total of 79 patients (28 female, 51 male, aged 42.1 ± 18.5) fulfilled the study inclusion criteria. A total of 46 patients were classified in purulent meningitis group whereas 33 were in aseptic meningitis/encephalitis group. Pathogens were detected by multiplex PCR in 41 patients. CSF cultures were positive in 10 (21.7%) patients (nine S.pneumoniae, one H.influenzae) and PCR were positive for 27 (58.6%) patients in purulent meningitis group. In this group one type of bacteria were detected in 18 patients (14 S.pneumoniae, two N

  13. SU-E-T-407: Evaluation of Four Commercial Dosimetry Systems for Routine Patient-Specific Tomotherapy Delivery Quality Assurance

    International Nuclear Information System (INIS)

    Xing, A; Arumugam, S; Deshpande, S; George, A; Holloway, L; Vial, P; Goozee, G

    2014-01-01

    Purpose: The purpose of this project was to evaluate the performance of four commercially available dosimetry systems for Tomotherapy delivery quality assurance (DQA). Methods: Eight clinical patient plans were chosen to represent a range of treatment sites and typical clinical plans. Four DQA plans for each patient plan were created using the TomoTherapy DQA Station (Hi-Art version 4.2.1) on CT images of the ScandiDose Delta4, IBA MatriXX Evolution, PTW Octavius 4D and Sun Nuclear ArcCHECK phantoms. Each detector was calibrated following the manufacture-provided procedure. No angular response correction was applied. All DQA plans for each detector were delivered on the Tomotherapy Hi-Art unit in a single measurement session but on different days. The measured results were loaded into the vendor supplied software for each QA system for comparison with the TPS-calculated dose. The Gamma index was calculated using 3%/3mm, 2%/2mm with 10% dose threshold of maximum TPS calculated dose. Results: Four detector systems showed comparable gamma pass rates for 3%/3m, which is recommended by AAPM TG119 and commonly used within the radiotherapy community. The averaged pass rates ± standard deviation for all DQA plans were (98.35±1.97)% for ArcCHECK, (99.9%±0.87)% for Matrix, (98.5%±5.09)% for Octavius 4D, (98.7%±1.27)% for Delata4. The rank of the gamma pass rate for individual plans was consistent between detectors. Using 2%/2mm Gamma criteria for analysis, the Gamma pass rate decreased on average by 9%, 8%, 6.6% and 5% respectively. Profile and Gamma failure map analysis using the software tools from each dosimetry system indicated that decreased passing rate is mainly due to the threading effect of Tomo plan. Conclusion: Despite the variation in detector type and resolution, phantom geometry and software implementation, the four systems demonstrated similar dosimetric performance, with the rank of the gamma pass rate consistent for the plans considered

  14. Customisation of a Monte Carlo dosimetry tool for dental cone-beam CT systems

    International Nuclear Information System (INIS)

    Stratis, A.; Lopez-Rendon, X.; Jacobs, R.; Zhang, G.; Bogaerts, R.; Bosmans, H.

    2016-01-01

    A versatile EGSnrc Monte Carlo (MC) framework, initially designed to explicitly simulate X-ray tubes and record the output data into phase space data files, was modified towards dental cone-beam computed tomography (CBCT) dosimetric applications by introducing equivalent sources. Half value layer (HVL) measurements were conducted to specify protocol-specific energy spectra. Air kerma measurements were carried out with an ionisation chamber positioned against the X-ray tube to obtain the total filtration attenuation characteristics. The framework is applicable to bow-tie and non-bow-tie inherent filtrations, and it accounts for the anode heel effect and the total filtration of the tube housing. The code was adjusted to the Promax 3D Max (Planmeca, Helsinki, Finland) dental CBCT scanner. For each clinical protocol, calibration factors were produced to allow absolute MC dose calculations. The framework was validated by comparing MC calculated doses and measured doses in a cylindrical water phantom. Validation results demonstrate the reliability of the framework for dental CBCT dosimetry purposes. (authors)

  15. Radiation protection in medicine (542) comparison of different dosimetry systems for dose measurements in diagnostic radiology

    International Nuclear Information System (INIS)

    Milkovic, D.; Ranogajec-Komor, M.; Miljanic, S.; Knezevic, Z.; Krpan, K.

    2006-01-01

    The dose measurement on patients in X-ray diagnostic is not simple, because low doses with low and various energies have to be measured. The aim of this preliminary study was to compare high sensitivity thermoluminescent dosimeter (T.L.D.) (LiF:Mg,Cu,P) and radio-photoluminescent (R.P.L.) glass dosimeters for dose measurements in routine X-ray diagnostic of chest of children. The energy dependence of the dosimeters was investigated in Secondary Standard Dosimetry Laboratory (SSDL). The energy range was 33- 65 keV mean energy, the dosimeters were placed free in air and on the water phantom. The results were compared to calculated values of Hp(10). The next step was the irradiation in a routine X-ray diagnostic unit. Irradiations were performed by the Shimadzu X-ray unit. The selected irradiation conditions were the same as that most commonly used for baby examinations. Doses were measured with dosimeters placed free-in-air and also with the dosimeters placed on the water phantom and baby phantom. The results show that the R.P.L. glass dosimeters and LiF:Mg,Cu,P based T.L.D. are suitable for low dose measurements in X-ray diagnostic. The uncertainty of dose determination is mainly caused by the energy dependence of dosimeters. (authors)

  16. Advancements in accuracy of the alanine dosimetry system. Part 1. The effects of environmental humidity

    International Nuclear Information System (INIS)

    Sleptchonok, Olga F.; Nagy, Vitaly; Desrosiers, Marc F.

    2000-01-01

    A one-year study of the EPR signal of γ-irradiated ( 60 Co) L-α-alanine with simultaneous monitoring of the cavity Q-factor was undertaken. The widespread opinion that the EPR signal remains absolutely stable under normal laboratory storage conditions is inaccurate. At 0% humidity, the signal can be regarded as stable within ±1% of its initial value for 6 months for 1 and 10 kGy doses, but for only 3 months for 100 kGy. When stored at the same relative humidity values up to 60%, the fading rates for dosimeters irradiated to 1 and 10 kGy are similar, whereas signals of dosimeters irradiated to 100 kGy fade considerably faster for all humidities. The rates of fading increase with the relative humidity, especially above 60% R. H. Environmental humidity also deteriorates the accuracy of alanine dosimetry by changing the resonant cavity Q-factor. This is particularly important when irradiated alanine dosimeters are used as instrument calibration standards. Short-term changes in alanine EPR signal amplitudes were recorded upon removal of the irradiated dosimeters from their storage environments. The importance of an in situ standard to correct for measurement errors due to environmental effects is demonstrated. (author)

  17. FNTD radiation dosimetry system enhanced with dual-color wide-field imaging

    International Nuclear Information System (INIS)

    Akselrod, M.S.; Fomenko, V.V.; Bartz, J.A.; Ding, F.

    2014-01-01

    At high neutron and photon doses Fluorescent Nuclear Track Detectors (FNTDs) require operation in analog mode and the measurement results depend on individual crystal color center concentration (coloration). We describe a new method for radiation dosimetry using FNTDs, which includes non-destructive, automatic sensitivity calibration for each individual FNTD. In the method presented, confocal laser scanning fluorescent imaging of FNTDs is combined with dual-color wide field imaging of the FNTD. The calibration is achieved by measuring the color center concentration in the detector through fluorescence imaging and reducing the effect of diffuse reflection on the lapped surface of the FNTD by imaging with infra-red (IR) light. The dual-color imaging of FNTDs is shown to provide a good estimation of the detector sensitivity at high doses of photons and neutrons, where conventional track counting is impeded by track overlap. - Highlights: • New method and optical imaging head was developed for FNTD used at high doses. • Dual-color wide-field imaging used for color center concentration measurement. • Green fluorescence corrected by diffuse reflection used for sensitivity correction. • FNTD dose measurements performed in analog processing mode

  18. The database system for dosimetry service at THE Institute of Nuclear Physics Polish Academy of Sciences

    International Nuclear Information System (INIS)

    Kopec, R.; Puchalska, M.; Olko, P.; Budzanowski, M.

    2005-01-01

    Full text: Laboratory of Individual and Environment Dosimetry (LADIS) at Institute of Nuclear Physics (IFJ) Polish Academy of Sciences in Krakow was formally established and accredited in 2001, based on the 30 years of experience of the local dosimetric service. The service is based on self-developed thermoluminescent detectors MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P), three automatic: ACARD and DOSACUS readers and two manual RA-94 readers. The rapid increase of the number of customers from 200 in 2001 to 6000 in 2004 stimulated the development of the dedicated DosBaz data base. The database was built using the MS Access platform. The content of the data structure was elaborated according to the EUR 14852 EN recommendations. In particular, customers are identified with unique ID numbers, the establishment (e.g. name, contact, street and number/PO box, town, country, employer code number and telephone number), the site (e.g. name, contact) and the individual (e.g. full name, a unique number) as recommended in mentioned technical recommendations. The DosBaz allows for entire processing the data, including preparation of the final certificate, reporting for authorities, preparation of the statistics etc. The paper will discuss the structure of the database, show the dataflow and demonstrate the results of statistical evaluation of results. (author)

  19. A reliable user authentication and key agreement scheme for Web-based Hospital-acquired Infection Surveillance Information System.

    Science.gov (United States)

    Wu, Zhen-Yu; Tseng, Yi-Ju; Chung, Yufang; Chen, Yee-Chun; Lai, Feipei

    2012-08-01

    With the rapid development of the Internet, both digitization and electronic orientation are required on various applications in the daily life. For hospital-acquired infection control, a Web-based Hospital-acquired Infection Surveillance System was implemented. Clinical data from different hospitals and systems were collected and analyzed. The hospital-acquired infection screening rules in this system utilized this information to detect different patterns of defined hospital-acquired infection. Moreover, these data were integrated into the user interface of a signal entry point to assist physicians and healthcare providers in making decisions. Based on Service-Oriented Architecture, web-service techniques which were suitable for integrating heterogeneous platforms, protocols, and applications, were used. In summary, this system simplifies the workflow of hospital infection control and improves the healthcare quality. However, it is probable for attackers to intercept the process of data transmission or access to the user interface. To tackle the illegal access and to prevent the information from being stolen during transmission over the insecure Internet, a password-based user authentication scheme is proposed for information integrity.

  20. Advances in biomedical dosimetry

    International Nuclear Information System (INIS)

    1981-01-01

    Full text: Radiation dosimetry, the accurate determination of the absorbed dose within an irradiated body or a piece of material, is a prerequisite for all applications of ionizing radiation. This has been known since the very first radiation applications in medicine and biology, and increasing efforts are being made by radiation researchers to develop more reliable, effective and safe instruments, and to further improve dosimetric accuracy for all types of radiation used. Development of new techniques and instrumentation was particularly fast in the field of both medical diagnostic and therapeutic radiology. Thus, in Paris in October the IAEA held the latest symposium in its continuing series on dosimetry in medicine and biology. The last one was held in Vienna in 1975. High-quality dosimetry is obviously of great importance for human health, whether the objectives lie in the prevention and control of risks associated with the nuclear industry, in medical uses of radioactive substances or X-ray beams for diagnostic purposes, or in the application of photon, electron or neutron beams in radiotherapy. The symposium dealt with the following subjects: General aspects of dosimetry; Special physical and biomedical aspects; Determination of absorbed dose; Standardization and calibration of dosimetric systems; and Development of dosimetric systems. The forty or so papers presented and the discussions that followed them brought out a certain number of dominant themes, among which three deserve particular mention. - The recent generalization of the International System of Units having prompted a fundamental reassessment of the dosimetric quantities to be considered in calibrating measuring instruments, various proposals were advanced by the representatives of national metrology laboratories to replace the quantity 'exposure' (SI unit = coulomb/kg) by 'Kerma' or 'absorbed dose' (unit joule/kg, the special name of which is 'gray'), this latter being closer to the practical

  1. Acquired neuropathies.

    Science.gov (United States)

    Lozeron, Pierre; Trocello, Jean-Marc; Kubis, Nathalie

    2013-09-01

    Acquired neuropathies represent most of the neuropathies encountered in clinical practice. Hundreds of causes have been identified even though up to 41% of patients are still classified as idiopathic (Rajabally and Shah in J Neurol 258:1431-1436, 1). Routine evaluation relies on comprehensive medical history taking, clinical examination, nerve conduction studies and laboratory tests. Other investigations such as nerve biopsy or nerve or muscle imaging are performed in specific settings. This review focuses on recent advances in acquired neuropathies.

  2. Dosimetry in radiotherapy using a-Si EPIDs: Systems, methods, and applications focusing on 3D patient dose estimation

    Science.gov (United States)

    McCurdy, B. M. C.

    2013-06-01

    An overview is provided of the use of amorphous silicon electronic portal imaging devices (EPIDs) for dosimetric purposes in radiation therapy, focusing on 3D patient dose estimation. EPIDs were originally developed to provide on-treatment radiological imaging to assist with patient setup, but there has also been a natural interest in using them as dosimeters since they use the megavoltage therapy beam to form images. The current generation of clinically available EPID technology, amorphous-silicon (a-Si) flat panel imagers, possess many characteristics that make them much better suited to dosimetric applications than earlier EPID technologies. Features such as linearity with dose/dose rate, high spatial resolution, realtime capability, minimal optical glare, and digital operation combine with the convenience of a compact, retractable detector system directly mounted on the linear accelerator to provide a system that is well-suited to dosimetric applications. This review will discuss clinically available a-Si EPID systems, highlighting dosimetric characteristics and remaining limitations. Methods for using EPIDs in dosimetry applications will be discussed. Dosimetric applications using a-Si EPIDs to estimate three-dimensional dose in the patient during treatment will be overviewed. Clinics throughout the world are implementing increasingly complex treatments such as dynamic intensity modulated radiation therapy and volumetric modulated arc therapy, as well as specialized treatment techniques using large doses per fraction and short treatment courses (ie. hypofractionation and stereotactic radiosurgery). These factors drive the continued strong interest in using EPIDs as dosimeters for patient treatment verification.

  3. Development of a TLD mailed system for remote dosimetry audit for 192Ir HDR and PDR sources

    International Nuclear Information System (INIS)

    Roue, Amelie; Venselaar, Jack L.M.; Ferreira, Ivaldo H.; Bridier, Andre; Dam, Jan van

    2007-01-01

    Background and purpose: In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. Materials and methods: A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from 192 Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an 192 Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1 s). Results: To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. Conclusion: A method of absorbed dose to water determination in the vicinity of an 192 Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The

  4. Development of a TLD mailed system for remote dosimetry audit for (192)Ir HDR and PDR sources.

    Science.gov (United States)

    Roué, Amélie; Venselaar, Jack L M; Ferreira, Ivaldo H; Bridier, André; Van Dam, Jan

    2007-04-01

    In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from (192)Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an (192)Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1s). To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. A method of absorbed dose to water determination in the vicinity of an (192)Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The accuracy of the procedure was determined. This method allows a

  5. Characterization of internal dosimetry practices

    International Nuclear Information System (INIS)

    Traub, R.J.; Heid, K.R.; Mann, J.C.

    1983-01-01

    Current practices in internal dosimetry at DOE facilities were evaluated with respect to consistency among DOE Contractors. All aspects of an internal dosimetry program were addressed. Items considered include, but are not necessarily limited to, record systems and ease of information retrieval; ease of integrating internal dose and external dose; modeling systems employed, including ability to modify models depending on excretion data, and verification of computer codes utilized; bioassay procedures, including quality control; and ability to relate air concentration data to individual workers and bioassay data. Feasibility of uranium analysis in solution by laser fluorescence excitation at uranium concentrations of one part per billion was demonstrated

  6. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with the design and measurement of physical parameters used in theory or to support biological experiments. The radiation biophysics program tests and uses the theoretical developments for experimental design, and provides information for further theoretical development through experiments on cellular systems

  7. Radiation dosimetry and radiation biophysics

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Radiation dosimetry and radiation biophysics are two closely integrated programs whose joint purpose is to explore the connections between the primary physical events produced by radiation and their biological consequences in cellular systems. The radiation dosimetry program includes the theoretical description of primary events and their connection with the observable biological effects. This program also is concerned with design and measurement of those physical parameters used in the theory or to support biological experiments. The radiation biophysics program tests and makes use of the theoretical developments for experimental design. Also, this program provides information for further theoretical development through experiments on cellular systems

  8. A Comprehensive Program to Reduce Rates of Hospital-Acquired Pressure Ulcers in a System of Community Hospitals.

    Science.gov (United States)

    Englebright, Jane; Westcott, Ruth; McManus, Kathryn; Kleja, Kacie; Helm, Colleen; Korwek, Kimberly M; Perlin, Jonathan B

    2018-03-01

    The prevention of hospital-acquired pressure ulcers (PrUs) has significant consequences for patient outcomes and the cost of care. Providers are challenged with evaluating available evidence and best practices, then implementing programs and motivating change in various facility environments. In a large system of community hospitals, the Reducing Hospital Acquired-PrUs Program was developed to provide a toolkit of best practices, timely and appropriate data for focusing efforts, and continuous implementation support. Baseline data on PrU rates helped focus efforts on the most vulnerable patients and care situations. Facilities were empowered to use and adapt available resources to meet local needs and to share best practices for implementation across the system. Outcomes were measured by the rate of hospital-acquired PrUs, as gathered from patient discharge records. The rate of hospital-acquired stage III and IV PrUs decreased 66.3% between 2011 and 2013. Of the 149 participating facilities, 40 (27%) had zero hospital-acquired stage III and IV PrUs and 77 (52%) had a reduction in their PrU rate. Rates of all PrUs documented as present on admission did not change during this period. A comparison of different strategies used by the most successful facilities illustrated the necessity of facility-level flexibility and recognition of local workflows and patient demographics. Driven by the combination of a repository of evidence-based tools and best practices, readily available data on PrU rates, and local flexibility with processes, the Reducing Hospital Acquired-PrUs Program represents the successful operationalization of improvement in a wide variety of facilities.

  9. Quality study of portal images acquired by computed radiography and screen-film system under megavoltage ray

    International Nuclear Information System (INIS)

    Cao Guoquan; Jin Xiance; Wu Shixiu; Xie Congying; Zhang Li; Yu Jianyi; Li Yueqing

    2007-01-01

    Objective: To evaluate the quality of the portal images acquired by computed radiography (CR) system and conventional screen-film system, respectively. Methods: Imaging plates (IP) and X-ray films ora home-devised lead phantom with a leakage of 6.45% were acquired, and modulation transfer function (MTF) curves of the both images were measured using edge method. Portal images of 40 nasopharyngeal cancer patients were acquired by IP and screen-film system respectively. Two doctors with similar experience evaluated the damage degree of petrosal bone, the receiver operating characteristic (ROC) curve of CR images and general images were drawn according to two doctors evaluation results. Results: The identification frequency of CR system and screen-film system were 1.159 and 0.806 Lp/mm respectively. For doctor one, the area under ROC curve of CR images and general images were 0.802 and 0.742 respectively. For doctor two, the area under ROC curve of CR images and general images were 0.751 and 0.600 respectively. The MTF curve and ROC curve of CR are both better than those of screen-film system. Conclusion: The image quality of CR portal imaging is much better than that of screen-film system. The utility of CR in linear accelerator for portal imaging is promising in clinic. (authors)

  10. Systemic acquired resistance in soybean is regulated by two proteins, Orthologous to Arabidopsis NPR1

    Directory of Open Access Journals (Sweden)

    Sandhu Devinder

    2009-08-01

    Full Text Available Abstract Background Systemic acquired resistance (SAR is induced in non-inoculated leaves following infection with certain pathogenic strains. SAR is effective against many pathogens. Salicylic acid (SA is a signaling molecule of the SAR pathway. The development of SAR is associated with the induction of pathogenesis related (PR genes. Arabidopsis non-expressor of PR1 (NPR1 is a regulatory gene of the SA signal pathway 123. SAR in soybean was first reported following infection with Colletotrichum trancatum that causes anthracnose disease. We investigated if SAR in soybean is regulated by a pathway, similar to the one characterized in Arabidopsis. Results Pathogenesis-related gene GmPR1 is induced following treatment of soybean plants with the SAR inducer, 2,6-dichloroisonicotinic acid (INA or infection with the oomycete pathogen, Phytophthora sojae. In P. sojae-infected plants, SAR was induced against the bacterial pathogen, Pseudomonas syringae pv. glycinea. Soybean GmNPR1-1 and GmNPR1-2 genes showed high identities to Arabidopsis NPR1. They showed similar expression patterns among the organs, studied in this investigation. GmNPR1-1 and GmNPR1-2 are the only soybean homologues of NPR1and are located in homoeologous regions. In GmNPR1-1 and GmNPR1-2 transformed Arabidopsis npr1-1 mutant plants, SAR markers: (i PR-1 was induced following INA treatment and (ii BGL2 following infection with Pseudomonas syringae pv. tomato (Pst, and SAR was induced following Pst infection. Of the five cysteine residues, Cys82, Cys150, Cys155, Cys160, and Cys216 involved in oligomer-monomer transition in NPR1, Cys216 in GmNPR1-1 and GmNPR1-2 proteins was substituted to Ser and Leu, respectively. Conclusion Complementation analyses in Arabidopsis npr1-1 mutants revealed that homoeologous GmNPR1-1 and GmNPR1-2 genes are orthologous to Arabidopsis NPR1. Therefore, SAR pathway in soybean is most likely regulated by GmNPR1 genes. Substitution of Cys216 residue, essential

  11. Systemic acquired resistance in soybean is regulated by two proteins, Orthologous to Arabidopsis NPR1.

    Science.gov (United States)

    Sandhu, Devinder; Tasma, I Made; Frasch, Ryan; Bhattacharyya, Madan K

    2009-08-05

    Systemic acquired resistance (SAR) is induced in non-inoculated leaves following infection with certain pathogenic strains. SAR is effective against many pathogens. Salicylic acid (SA) is a signaling molecule of the SAR pathway. The development of SAR is associated with the induction of pathogenesis related (PR) genes. Arabidopsis non-expressor of PR1 (NPR1) is a regulatory gene of the SA signal pathway 123. SAR in soybean was first reported following infection with Colletotrichum trancatum that causes anthracnose disease. We investigated if SAR in soybean is regulated by a pathway, similar to the one characterized in Arabidopsis. Pathogenesis-related gene GmPR1 is induced following treatment of soybean plants with the SAR inducer, 2,6-dichloroisonicotinic acid (INA) or infection with the oomycete pathogen, Phytophthora sojae. In P. sojae-infected plants, SAR was induced against the bacterial pathogen, Pseudomonas syringae pv. glycinea. Soybean GmNPR1-1 and GmNPR1-2 genes showed high identities to Arabidopsis NPR1. They showed similar expression patterns among the organs, studied in this investigation. GmNPR1-1 and GmNPR1-2 are the only soybean homologues of NPR1and are located in homoeologous regions. In GmNPR1-1 and GmNPR1-2 transformed Arabidopsis npr1-1 mutant plants, SAR markers: (i) PR-1 was induced following INA treatment and (ii) BGL2 following infection with Pseudomonas syringae pv. tomato (Pst), and SAR was induced following Pst infection. Of the five cysteine residues, Cys82, Cys150, Cys155, Cys160, and Cys216 involved in oligomer-monomer transition in NPR1, Cys216 in GmNPR1-1 and GmNPR1-2 proteins was substituted to Ser and Leu, respectively. Complementation analyses in Arabidopsis npr1-1 mutants revealed that homoeologous GmNPR1-1 and GmNPR1-2 genes are orthologous to Arabidopsis NPR1. Therefore, SAR pathway in soybean is most likely regulated by GmNPR1 genes. Substitution of Cys216 residue, essential for oligomer-monomer transition of Arabidopsis NPR1

  12. Dosimetry in nuclear power plants

    International Nuclear Information System (INIS)

    Lastra B, J. A.

    2008-12-01

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  13. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  14. Dosimetry for radiation processing

    DEFF Research Database (Denmark)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  15. Aqueous chemical dosimetry

    International Nuclear Information System (INIS)

    Matthews, R.W.

    1982-01-01

    Aqueous chemical dosimetry based on ceric and ferrous sulfate solutions and on a number of fluorescence-induced systems is reviewed. Particular attention is given to the factors affecting the response of these dosimeters to radiation and the corrections necessary for more accurate dosimetry under various irradiation conditions. The effect of cerous and ceric ion, oxygen, and sulfuric acid concentration on the ceric dosimeter is discussed together with the effects of temperature, energy of radiation, degraded energy spectra, and peroxysulfuric acids. Practical aspects of ceric/cerous dosimetry are given. Although ferrous sulfate solution is the most important and widely studied reference dosimeter, general agreement has not been reached on the ''best'' value for the molar extinction coefficient of ferric ions nor on the correction necessary to the G(Fe 3 - ) value for irradiations at temperatures significantly different from 25 0 C. New data are presented which indicate that the larger temperature coefficients given in the literature are more accurate. The ferrous sulfate system has been of great importance in establishing the primary radiolytic yields for 0.4 M sulfuric acid solution; it is shown how the failure to take into account the effect of oxygen and ferrous sulfate concentrations has led to erroneously high estimates of the zero solute concentration values in acid solutions. Some of the methods for extending the dose ranges measurable with ferrous sulfate-based solutions are reviewed. Substances which on irradiation give highly fluorescent products are among the most sensitive aqueous chemical dosimeters. These include benzoate and terephthalate solutions and the more recent coumarin and trimesate solutions. Advantages and disadvantages system are discussed. (author)

  16. Neutron dosimetry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  17. External audit in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Thwaites, D.I.; Western General Hospital, Edinburgh

    1996-01-01

    Quality audit forms an essential part of any comprehensive quality assurance programme. This is true in radiotherapy generally and in specific areas such as radiotherapy dosimetry. Quality audit can independently test the effectiveness of the quality system and in so doing can identify problem areas and minimize their possible consequences. Some general points concerning quality audit applied to radiotherapy are followed by specific discussion of its practical role in radiotherapy dosimetry, following its evolution from dosimetric intercomparison exercises to routine measurement-based on-going audit in the various developing audit networks both in the UK and internationally. Specific examples of methods and results are given from some of these, including the Scottish+ audit group. Quality audit in radiotherapy dosimetry is now well proven and participation by individual centres is strongly recommended. Similar audit approaches are to be encouraged in other areas of the radiotherapy process. (author)

  18. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Hoefert, M.; Nielsen, M.

    1996-01-01

    In 1995 both the Individual Dosimetry and Calibration Sections worked under the condition of a status quo and concentrated fully on the routine part of their work. Nevertheless, the machine for printing the bar code which will be glued onto the film holder and hence identify the people when entering into high radiation areas was put into operation and most of the holders were equipped with the new identification. As far as the Calibration Section is concerned the project of the new source control system that is realized by the Technical Support Section was somewhat accelerated

  19. Tritium dosimetry and standardization

    International Nuclear Information System (INIS)

    Balonov, M.I.

    1983-01-01

    Actual problem of radiation hygiene such as an evaluation of human irradiation hazard due to a contact with tritium compounds both in industrial and public spheres is under discussion. Sources of tritium release to environment are characterized. Methods of tritium radiation monitoring are discussed. Methods of dosimetry of internal human exposure resulted from tritium compounds are developed on the base of modern representations on metbolism and tritium radiobiological effect. A system of standardization of permissible intake of tritium compounds for personnel and persons of population is grounded. Some protection measures are proposed as applied to tritium overdosage

  20. Personal dosimetry and information platforms

    International Nuclear Information System (INIS)

    Sanchez Hidalgo, M.; Galan Montenegro, P.; Bodineau Gil, C.; Hernandez Rodriguez, R.; Jimenez Nartin, A.; Cano Sanchez, J. J.

    2011-01-01

    One question often raised by the hospital personnel dosimetry is the high incidence in the no monthly turnover of dosimeters, which is currently a high number of administrative dose assignments. The high number of workers with personal dosimetry and in many cases, the dispersion of workplaces makes it impossible to personalized management. To make a more direct and personal, and transmit information quickly and with guaranteed reception, has developed and implemented a system of personalized dosimetric information through messaging Short Message Service (SMS) and access to the history of dosimetric dosimetric and management through web space Service Hospital Radio physics.

  1. Incidence of skin cancer in Nagasaki atomic bomb survivors based on DS86 dosimetry system, 1958-1985

    Energy Technology Data Exchange (ETDEWEB)

    Sadamori, Naoki (Nagasaki Univ. (Japan). School of Medicine); Otake, Masanori; Honda, Takeo

    1992-03-01

    The incidence of skin cancer during the period 1958-1985 was examined in the population registered in the life span study extension (LSSE) and the adult health study (AHS). Among 25,942 A-bomb survivors in whom DS86 was available, skin cancer was confirmed in 47 A-bomb survivors. These A-bomb survivors consisted of 24 males and 23 females. According to DS86 dosimetry system, ten A-bomb survivors had been exposed to 0.50 Gy or more. The most common histology was basal cell epithelioma (n=25), followed by malignant melanoma (n=4) and basosquamous cell carcinoma and sweat gland carcinoma (one each). In the group of 0.50 Gy or more, the incidence of occurrence of skin cancer was 20.8/100,000 population per year (PY) for the LSSE population and 22.8/100,000 PY for the AHS population. In the group of 0.01-0.49 Gy, it was 6.8/100,000 PY for the LSSE population and 12.8/100,000 PY for the AHS population. It was significantly associated with higher exposure doses. The dose-response relationship was linear. (N.K.).

  2. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  3. Individual dosimetry of workers and patients: implementation and perspectives

    International Nuclear Information System (INIS)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E.

    2008-01-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  4. 3-D dosimetric evaluation of 2.5 mm HD120 multileaf system for intensity modulated stereotactic radiosurgery using optical CT based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Wuu, C-S; Kessel, Jack; Xu, Y

    2009-01-01

    A Trilogy TX equipped with a 2.5 mm HD120 multileaf collimator system is available for the treatment of radiosurgery and IMRT. In this study, we evaluated the 3-D dosimetric impact of leaf width on an IMRT radiosurgery plan by comparing the target coverage and the dose gradient around the target, produced from both a 2.5 mm HD120 high-definition MLC system and a 5mm-leaf-width millennium 120 MLC system, using an optical CT based polymer gel dosimetry system. The 2.5 mm MLC improves target conformity and surrounding tissue sparing when compared to that of 5 mm MLC.

  5. Applications of gel dosimetry

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  6. Manual of food irradiation dosimetry

    International Nuclear Information System (INIS)

    1977-01-01

    Following items are discussed: Fundamentals of dosimetry; description of irradiators; dose distribution in the product and commissioning the process; plant operation and process control; detailed instructions on using various dose-meter systems; references; glossary of some basic terms and concepts

  7. Present status of fast neutron personnel dosimetry system based on CR-39 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Pal, Rupali; Sathian, Deepa; Jayalakshmi, V.; Bakshi, A.K.; Chougaonkar, M.P.; Mayya, Y.S.; Kumar, Valli; Babu, Rajesh; Kar, S.; Joshi, V.M.

    2011-08-01

    Neutron sources are of different types depending upon the method of production such as nuclear reactors, particle accelerators and laboratory sources. Neutron sources depending upon their energy, flux, size etc. are used for variety of applications in basic and applied sciences, neutron scattering experiments and in industry such as oil well - digging, coal mining and processing, ore processing etc. Personnel working in nuclear installations such as reactors, accelerators, spent fuel processing plants, nuclear fuel cycle operations and those working in various industries such as oil refining, oil well-digging, coal mining and processing, ore processing, etc. need to be monitored for neutron exposures, if any. Neutron monitoring is especially necessary in view of the fact that the radiation weighting factor for neutron is much higher than gamma rays and also it varies with energy. Radiological Physics and Advisory Division is involved in monitoring of personnel working in neutron fields. Around 2100 workers from 70 institutions (DAE and Non-DAE) are monitored on a quarterly basis. Neutron personnel monitoring, carried out in the country is based on Solid State Nuclear Track Detection (SSNTD) technique. In this technique, neutrons interact with hydrogen in CR-39 polymer to produce recoil protons. These protons create damages in the polymer, which are enlarged and appear as tracks when subjected to electrochemical etching (ECE). These tracks are counted in an optical system to evaluate the neutron dose. The neutron dosimetry system based on SSNTD has undergone a significant development, since it was started in 1990. The development includes upgradation of image analysis system for counting tracks, introduction of chemical etching (CE) at elevated temperatures for evaluation of dose equivalents above 10 mSv and use of carbon laser for cutting of CR-39 detectors. The entire dose evaluation process has been standardized, which includes calibration and performance tests

  8. Neutron personnel dosimetry considerations for fusion reactors

    International Nuclear Information System (INIS)

    Barton, T.P.; Easterly, C.E.

    1979-07-01

    The increasing development of fusion reactor technology warrants an evaluation of personnel neutron dosimetry systems to aid in the concurrent development of a radiation protection program. For this reason, current state of knowledge neutron dosimeters have been reviewed with emphasis placed on practical utilization and the problems inherent in each type of dosimetry system. Evaluations of salient parameters such as energy response, latent image instability, and minimum detectable dose equivalent are presented for nuclear emulsion films, track etch techniques, albedo and other thermoluminescent dosimetry techniques, electrical conductivity damage effects, lyoluminescence, thermocurrent, and thermally stimulated exoelectron emission. Brief summaries of dosimetry regulatory requirements and intercomparison study results help to establish compliance and recent trends, respectively. Spectrum modeling data generated by the Neutron Physics Division of Oak Ridge National Laboratory for the Princeton Tokamak Fusion Test Reactor (TFTR) Facility have been analyzed by both International Commission on Radiological Protection fluence to dose conversion factors and an adjoint technique of radiation dosimetry, in an attempt to determine the applicability of current neutron dosimetry systems to deuterium and tritium fusion reactor leakage spectra. Based on the modeling data, a wide range of neutron energies will probably be present in the leakage spectra of the TFTR facility, and no appreciable risk of somatic injury to occupationally exposed workers is expected. The relative dose contributions due to high energy and thermal neutrons indicate that neutron dosimetry will probably not be a serious limitation in the development of fusion power

  9. Acquired Methemoglobinaemia

    Directory of Open Access Journals (Sweden)

    Adil Al-Lawati

    2012-05-01

    Full Text Available Acquired methemoglobinaemia is a relatively rare condition and, therefore infrequently encountered in acute medical practice. Suspicion of the condition may be triggered when the measured PaO2 is ‘out of keeping’ with the oxygen saturations that are discovered with pulse oximetry. We describe two separate cases of acquired methemoglobinaemia secondary to the recreational use of alkyl nitrites (’poppers’. The patients presented at separate times to two different teaching hospitals in London, UK. The similarity of these cases has led the authors to conclude that a raised awareness of this potentially fatal condition, and its association with a widely-available recreational drug, is necessary to ensure a correct and timely diagnosis.

  10. Smart dosimetry by pattern recognition using a single photon counting detector system in time over threshold mode

    International Nuclear Information System (INIS)

    Reza, S; Wong, W S; Fröjdh, E; Norlin, B; Fröjdh, C; Thungström, G; Thim, J

    2012-01-01

    The function of a dosimeter is to determine the absorbed dose of radiation, for those cases in which, generally, the particular type of radiation is already known. Lately, a number of applications have emerged in which all kinds of radiation are absorbed and are sorted by pattern recognition, such as the Medipix2 application in [1]. This form of smart dosimetry enables measurements where not only the total dosage is measured, but also the contributions of different types of radiation impacting upon the detector surface. Furthermore, the use of a photon counting system, where the energy deposition can be measured in each individual pixel, ensures measurements with a high degree of accuracy in relation to the pattern recognition. In this article a Timepix [2] detector system has been used in the creation of a smart dosimeter for Alpha, Beta and Gamma radiation. When a radioactive particle hits the detector surface it generates charge clusters and those impacting upon the detector surface are read out and image processing algorithms are then used to classify each charge cluster. The individual clusters are calculated and as a result, the dosage for each type of radiation is given. In some cases, several particles can impact in roughly the same place, forming overlapping clusters. In order to handle this problem, a cluster separation method has been added to the pattern recognition algorithm. When the clusters have been separated, they are classified by shape and sorted into the correct type of radiation. The algorithms and methods used in this dosimeter have been developed so as to be simple and computationally effective, in order to enable implementation on a portable device.

  11. SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Samuel, D [Universite catholique de Louvain, Louvain-la-neuve, BW (Belgium); Testa, M; Park, Y [Massachusetts General Hospital, Boston, MA (United States); Schneider, R; Moteabbed, M [General Hospital, Boston, MA (United States); Janssens, G; Prieels, D [Ion Beam Applications, Louvain-la-neuve, Brabant Wallon (Belgium); Orban de Xivry, J [Universite catholique de Louvain, Louvain-la-neuve, BW (Belgium); Lu, H [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Bentefour, E

    2014-06-01

    Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separable into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.

  12. SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

    International Nuclear Information System (INIS)

    Samuel, D; Testa, M; Park, Y; Schneider, R; Moteabbed, M; Janssens, G; Prieels, D; Orban de Xivry, J; Lu, H; Bentefour, E

    2014-01-01

    Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separable into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient

  13. Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

    Energy Technology Data Exchange (ETDEWEB)

    Farah, J., E-mail: jad.farah@irsn.fr; Trompier, F. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Radioprotection de l’Homme, BP17, Fontenay-aux-Roses 92260 (France); Mares, V.; Schinner, K.; Wielunski, M. [Helmholtz Zentrum München, Institute of Radiation Protection, Ingolstädter Landstraße 1, Neuherberg 85764 (Germany); Romero-Expósito, M.; Domingo, C. [Departament de Física, Universitat Autònoma de Barcelona, Bellaterra E-08193 (Spain); Trinkl, S. [Helmholtz Zentrum München, Institute of Radiation Protection, Ingolstädter Landstraße 1, Neuherberg 85764, Germany and Physik-Department, Technische Universität München, Garching 85748 (Germany); Dufek, V. [Czech Technical University in Prague, FNSPE, Břehová 7, Prague 115 19, Czech Republic and National Radiation Protection Institute, Bartoškova 28, Prague 140 00 (Czech Republic); Klodowska, M.; Liszka, M.; Stolarczyk, L.; Olko, P. [Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342 (Poland); Kubancak, J. [Czech Technical University in Prague, FNSPE, Břehová 7, Prague 115 19, Czech Republic and Department of Radiation Dosimetry, Nuclear Physics Institute, Řež CZ-250 68 (Czech Republic); and others

    2015-05-15

    Purpose: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. Methods: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9—Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H{sup ∗}(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs—tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm{sup 3}) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm{sup 2} field size. Results: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H{sup ∗}(10) value of ∼51 μSv Gy{sup −1}; this was measured at 1.15 m along the beam axis. H{sup ∗}(10) values

  14. Characterization of commercial MOSFETS electron dosimetry

    International Nuclear Information System (INIS)

    Carvajal, M. A.; Simancas, F.; Guirado, D.; Banqueri, J.; Vilches, M.; Lallena, A. M.; Palma, A. J.

    2011-01-01

    In recent years there have been commercial dosimetry devices based on transistors Metal-Oxide-Semiconductor (MOSFET) having a number of advantages over traditional systems for dosimetry in medical applications. These include the portability of the sensor element and a reading process quick and relatively simple dose, linearity, and so on. The use of electron beams is important in modern radiotherapy include its use in intra-operative radiotherapy (RIO). This paper presents an initial characterization of different business models MOSFET, not specific for radiation detection, to demonstrate their potential as sensors for electron beam dosimetry. (Author)

  15. SU-E-T-425: Feasibility of Establishing a National Postal Dosimetry System Using EBT3 Gafchromic Film

    International Nuclear Information System (INIS)

    Abdel-Rahman, W; Mohammed, I; Bamajboor, S

    2015-01-01

    Purpose: To evaluate the performance of a postal dosimeter consisting of EBT3 films and a miniature Lucite phantom to be used for photon beams output audits for mega-voltage photon beams across the Saudi Arabia. Methods: Two batches of EBT3 films were calibrated in 5 mega-voltage photon beams with energies ranging between 6 MV and 18 MV in the dose range between 0 to 4 Gy. A 4×4×20 cm 3 lucite phantom was constructed to be used as an irradiation phantom. The lucite irradiation phantom consists of two parts and allows for embedding a 2.5×2.0 cm 2 EBT3 film at 8.9 cm depth. Factors that convert the dose measured in the lucite irradiation phantom at 8.9 cm depth to the dose at 10 cm depth in water for 10×10 cm 2 field for different photon energies were calculated using the dosxyznrc/EGSnrcMP user code. The performance of the proposed postal dosimeter was tested in 17 different photon beams across 4 radiotherapy centres in Saudi Arabia. The outputs of the 17 beams are monitored by either the International Atomic Energy Agency or by the Radiological Physics Centre. Results: For the 17 photon beams, the average of the ratios of measured to stated outputs was 1.01 ± 0.02 and with a maximum ratio of 1.05. Conclusion: The results of our work indicate that the proposed postal dosimetry system can be used for national auditing of outputs for mega-voltage photon beams. The service can be offered to other national radiotherapy centres or to a be used for credentialing of centres participating in national trials

  16. SU-E-T-425: Feasibility of Establishing a National Postal Dosimetry System Using EBT3 Gafchromic Film

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rahman, W [KING FAHAD SPECIALIST HOSPITAL, Dammam, Eastern Province (Saudi Arabia); Mohammed, I [King Fahd University of Petroleum & Minerals, Dhahran, Eastern Province (Saudi Arabia); Bamajboor, S [Prince Sultan Military Medical City, Riyadh, Riyadh (Saudi Arabia)

    2015-06-15

    Purpose: To evaluate the performance of a postal dosimeter consisting of EBT3 films and a miniature Lucite phantom to be used for photon beams output audits for mega-voltage photon beams across the Saudi Arabia. Methods: Two batches of EBT3 films were calibrated in 5 mega-voltage photon beams with energies ranging between 6 MV and 18 MV in the dose range between 0 to 4 Gy. A 4×4×20 cm{sup 3} lucite phantom was constructed to be used as an irradiation phantom. The lucite irradiation phantom consists of two parts and allows for embedding a 2.5×2.0 cm{sup 2} EBT3 film at 8.9 cm depth. Factors that convert the dose measured in the lucite irradiation phantom at 8.9 cm depth to the dose at 10 cm depth in water for 10×10 cm{sup 2} field for different photon energies were calculated using the dosxyznrc/EGSnrcMP user code. The performance of the proposed postal dosimeter was tested in 17 different photon beams across 4 radiotherapy centres in Saudi Arabia. The outputs of the 17 beams are monitored by either the International Atomic Energy Agency or by the Radiological Physics Centre. Results: For the 17 photon beams, the average of the ratios of measured to stated outputs was 1.01 ± 0.02 and with a maximum ratio of 1.05. Conclusion: The results of our work indicate that the proposed postal dosimetry system can be used for national auditing of outputs for mega-voltage photon beams. The service can be offered to other national radiotherapy centres or to a be used for credentialing of centres participating in national trials.

  17. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Mancosu, Pietro; Reggiori, Giacomo, E-mail: giacomo.reggiori@humanitas.it; Stravato, Antonella; Gaudino, Anna; Lobefalo, Francesca; Palumbo, Valentina; Tomatis, Stefano [Physics Service of Radiation Oncology Department, Clinical and Research Center, Rozzano, Milan 20098 (Italy); Navarria, Piera; Ascolese, Anna; Scorsetti, Marta [Radiation Oncology Department, Humanitas Clinical and Research Center, Rozzano, Milan 20089 (Italy); Picozzi, Piero [Neurosurgery Department, Humanitas Clinical and Research Center, Rozzano, Milan 20089 (Italy); Marinelli, Marco; Verona-Rinati, Gianluca [Dipartimento di Ingegneria Industriale, Università di Roma Tor Vergata, Roma 00133 (Italy)

    2015-09-15

    Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW-60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW-60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW-60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW-60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW-60019 is a suitable detector for commissioning and routine use of Gamma Knife with good agreement of both DORs and profiles in the three directions.

  18. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system

    International Nuclear Information System (INIS)

    Mancosu, Pietro; Reggiori, Giacomo; Stravato, Antonella; Gaudino, Anna; Lobefalo, Francesca; Palumbo, Valentina; Tomatis, Stefano; Navarria, Piera; Ascolese, Anna; Scorsetti, Marta; Picozzi, Piero; Marinelli, Marco; Verona-Rinati, Gianluca

    2015-01-01

    Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW-60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW-60019 measurements. Measured DORs were compared to the new output factor reference values for Gamma Knife Perfexion (0.814 and 0.900 for 4 and 8 mm, respectively). Profiles in the three directions were also measured for the 4 mm beam to evaluate full width at half maximum (FWHM) and penumbra and to compare them with the corresponding Leksell GammaPlan profiles. Results: FWHM and penumbra for PTW-60019 differed from the calculated values by less than 0.2 and 0.3 mm, for the parallel and transversal acquisitions, respectively. GafChromic films showed FWHM and penumbra within 0.1 mm. The output ratio obtained with the PTW-60019 for the 4 mm field was 1.6% greater in transverse direction compared to the nominal value. Comparable differences up to 0.8% and 1.0% for, respectively, GafChromic films and SFD were found. Conclusions: The microDiamond PTW-60019 is a suitable detector for commissioning and routine use of Gamma Knife with good agreement of both DORs and profiles in the three directions

  19. [Relationship between phenomenon of acquired activated protein C resistance and antiphospholipid antibodies in patients with systemic lupus erythematosus].

    Science.gov (United States)

    Hu, Y Q; Chen, F P; Xie, Q Z

    2001-10-28

    To determine the occurrence of activated protein C resistance (APCR), to identify APCR is associated with thrombotic events (TEs), and acquired APCR is associated with the presence of antiphospholipid antibodies (APLAs) in 30 patients with systemic lupus erythematosus (SLE). Laboratory tests included dilute Russell's viper venom time assay for LA (dRVVT-LA), ELISA assay for ACL, APC sensitivity ratio, and factor V Leiden were detected by PCR-Mnl/I digestion. Acquired APCR was presented in 14(46.67%) of 30 patients. Factor V Leiden was not found in any patients. The incidence of TEs in the APCR-positive patients was significantly higher than that in the APCR-negative patients (42.85% vs 6.25%, P TEs in the LA-positive patients was also significantly higher than that in the LA-negative patients (50% vs 11.1%, P TEs (P TEs. Acquired APCR may not reflect the interference of LAs with the protein C pathway which may represent a mechanism of LA-associated TEs.

  20. Incoherent digital holograms acquired by interferenceless coded aperture correlation holography system without refractive lenses.

    Science.gov (United States)

    Kumar, Manoj; Vijayakumar, A; Rosen, Joseph

    2017-09-14

    We present a lensless, interferenceless incoherent digital holography technique based on the principle of coded aperture correlation holography. The acquired digital hologram by this technique contains a three-dimensional image of some observed scene. Light diffracted by a point object (pinhole) is modulated using a random-like coded phase mask (CPM) and the intensity pattern is recorded and composed as a point spread hologram (PSH). A library of PSHs is created using the same CPM by moving the pinhole to all possible axial locations. Intensity diffracted through the same CPM from an object placed within the axial limits of the PSH library is recorded by a digital camera. The recorded intensity this time is composed as the object hologram. The image of the object at any axial plane is reconstructed by cross-correlating the object hologram with the corresponding component of the PSH library. The reconstruction noise attached to the image is suppressed by various methods. The reconstruction results of multiplane and thick objects by this technique are compared with regular lens-based imaging.

  1. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  2. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  3. A study on the development of personal radiation dosimetry system based on the pulsed optically stimulated luminescence of α-Al2O3:C

    International Nuclear Information System (INIS)

    Lee, Sang Yoon

    2000-02-01

    High quality radiation dosimetry is for workers who rely upon personal dosimeters to record the amount of radiation to which they are exposed. Radiation physicists have been exploring thermoluminescence dosimeter (TLD) for personal monitoring since the mid 1960s, although, widespread use has only occurred in the last 20 years as automated analytical systems and high quality TLD crystals became commercially available. nowadays, multiple TLD (thermoluminescence dosimeter) chips with appropriate physical filters are generally used for measurements of the personal dose equivalent quantities, H p (d). Though the TLD offers several advantages not possessed by radiological film, it does not offer the some type of advantages as films: re-analysis of an exposure situation is prohibited because the analysis process clears all of the useful dosimetric traps and a record of the luminescence intensity in the form of a glow curve is all that is available after analysis. In addition, the high heating temperatures restrict packaging methods and prevent competitively priced thin films of TLD crystal powders. Optically stimulated luminescence (OSL) technology avoids many engineering limitations imposed by the high heating temperatures used for TLD technology. OSL crystalline powders can be dispersed in various plastics unable to withstand the TLD heating regimen. With uniform dispersion in the plastic, mass-manufacturing techniques can produce large quantities of identically performing detectors. The first proposal conducted by Markey et al. for applications and potentials of α-AI 2 O 3 :C for OSL dosimetry opened a new era for this phosphor. Pulsed and continuous wave OSL studies carried out on α-AI 2 O 3 :C have shown that the material seems to be the most promising for routine application of OSL for dosimetric purposes. The main objective of this study is to develop a multi-area personal OSL dosimetry system using α-AI 2 O 3 :C by taking advantage of its optical properties and

  4. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  5. Analysis of the power system from an electron beam accelerator and the correlation with the theoretical dosimetry for radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir Luiz; Somessari, Elizabeth S. Ribeiro; Silveira, Carlos Gaia da; Calvo, Wilson Aparecido Parejo, E-mail: somessar@ipen.br, E-mail: esomessa@ipen.br, E-mail: cgsilvei@ipen.br, E-mail: wapcalvo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Radiation Technology Center at IPEN/CNEN-SP to simulate the energy efficiency of this industrial accelerator. Finally, it is also targeted to compare theoretical dosimetry using parameters of energy and beam current with data from the accelerator power system. This knowledge and technology will be very useful and essential for the control system upgrade of EBA, mainly Dynamitron DC1500/25/04, in view that radiation processing technology for industrial and environmental applications has been developed and used worldwide. (author)

  6. Analysis of the power system from an electron beam accelerator and the correlation with the theoretical dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Somessari, Samir Luiz; Somessari, Elizabeth S. Ribeiro; Silveira, Carlos Gaia da; Calvo, Wilson Aparecido Parejo

    2013-01-01

    Radiation Technology Center at IPEN/CNEN-SP to simulate the energy efficiency of this industrial accelerator. Finally, it is also targeted to compare theoretical dosimetry using parameters of energy and beam current with data from the accelerator power system. This knowledge and technology will be very useful and essential for the control system upgrade of EBA, mainly Dynamitron DC1500/25/04, in view that radiation processing technology for industrial and environmental applications has been developed and used worldwide. (author)

  7. Radiation dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.; Tagesson, M.; Ljungberg, M.; Strand, S.E.; Thomas, S.R.

    1999-01-01

    Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. A knowledge of the radiation dose received by different organs in the body is essential to an evaluation of the risks and benefits of any procedure. In this paper, current methods for internal dosimetry are reviewed, as they are applied in nuclear medicine. Particularly, the Medical Internal Radiation Dose (MIRD) system for dosimetry is explained, and many of its published resources discussed. Available models representing individuals of different age and gender, including those representing the pregnant woman are described; current trends in establishing models for individual patients are also evaluated. The proper design of kinetic studies for establishing radiation doses for radiopharmaceuticals is discussed. An overview of how to use information obtained in a dosimetry study, including that of the effective dose equivalent (ICRP 30) and effective dose (ICRP 60), is given. Current trends and issues in internal dosimetry, including the calculation of patient-specific doses and in the use of small scale and microdosimetry techniques, are also reviewed

  8. Thin film tritium dosimetry

    Science.gov (United States)

    Moran, Paul R.

    1976-01-01

    The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.

  9. Design of a system for neutrons dosimetry; Diseno de un sistema para dosimetria de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Ceron, P.; Rivera, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Paredes G, L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Sanchez, A. [IPN, Escuela Superior de Fisica y Matematicas, Av. Instituto Politecnico Nacional s/n, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico); Vega C, H. R., E-mail: victceronr@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-08-15

    At the present time diverse systems of detection of neutrons exist, as proportional counters based on BF{sub 3}, He{sub 3} and spectrometers of Bonner spheres. However, the cost and the complexity of the implementation of these systems put them far from the reach for dosimetric purposes. For these reasons a system of neutrons detection composed by a medium paraffin moderator that forms a 4π (spheres) arrangement and of several couples of thermoluminescent dosimeters TLD 600/TLD 700. The response of the system presents a minor repeatability to 5% in several assays when being irradiated with a {sup 239}PuBe source and a deviation of 13.8% in the Tl readings of four different spheres. The calibration factor of the system with regard to the neutrons source which was of 56.2 p Sv/nc also was calculated. These detectors will be used as passive monitors of photoneutrons in a radiotherapy room with lineal accelerator of high energy. (Author)

  10. Recent advances in Optical Computed Tomography (OCT) imaging system for three dimensional (3D) radiotherapy dosimetry

    Science.gov (United States)

    Rahman, Ahmad Taufek Abdul; Farah Rosli, Nurul; Zain, Shafirah Mohd; Zin, Hafiz M.

    2018-01-01

    Radiotherapy delivery techniques for cancer treatment are becoming more complex and highly focused, to enable accurate radiation dose delivery to the cancerous tissue and minimum dose to the healthy tissue adjacent to tumour. Instrument to verify the complex dose delivery in radiotherapy such as optical computed tomography (OCT) measures the dose from a three-dimensional (3D) radiochromic dosimeter to ensure the accuracy of the radiotherapy beam delivery to the patient. OCT measures the optical density in radiochromic material that changes predictably upon exposure to radiotherapy beams. OCT systems have been developed using a photodiode and charged coupled device (CCD) as the detector. The existing OCT imaging systems have limitation in terms of the accuracy and the speed of the measurement. Advances in on-pixel intelligence CMOS image sensor (CIS) will be exploited in this work to replace current detector in OCT imaging systems. CIS is capable of on-pixel signal processing at a very fast imaging speed (over several hundred images per second) that will allow improvement in the 3D measurement of the optical density. The paper will review 3D radiochromic dosimeters and OCT systems developed and discuss how CMOS based OCT imaging will provide accurate and fast optical density measurements in 3D. The paper will also discuss the configuration of the CMOS based OCT developed in this work and how it may improve the existing OCT system.

  11. Development of DL-alanine systems for gamma radiation and electron dosimetry

    International Nuclear Information System (INIS)

    Costa, Zelia Maria da

    1994-01-01

    Two different dosimetric systems using DL-Alanine samples were employed to determine the absorbed dose from 60 Co gamma-rays source and electrons emitted from an accelerator. The first dosimetric system is based on the relationship between free radicals produced and the absorbed dose using the electron spin resonance (ESR) technique. Details on the sample preparation, the spectrometer parameter setting, the analysis of the ESR signal to dose, the influence of dose rate and the radiation type dependence are described. The second dosimetric system is based on the determination by absorbance spectrophotometry of the complex produced, which are formed when the irradiated alanine is dissolved in a solution containing ferrous ammonium sulphate xylenol in 0,05 N H 2 SO 4 . Different concentrations for each reagents has been analyzed in the preparation of this solution as well as the influence caused by radiation type and dose rate in the absorbance. (author)

  12. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  13. Pediatric patient with systemic lupus erythematosus & congenital acquired immunodeficiency syndrome: An unusual case and a review of the literature

    Directory of Open Access Journals (Sweden)

    Rezaee Fariba

    2008-05-01

    Full Text Available Abstract The coexistence of systemic lupus erythematosus (SLE in patients with congenital human immunodeficiency virus (HIV infection is rare. This is a case report of a child diagnosed with SLE at nine years of age. She initially did well on non-steroidal anti-inflammatory agents, hydroxychloroquine, and steroids. She then discontinued her anti-lupus medications and was lost to follow-up. At 13 years of age, her lupus symptoms had resolved and she presented with intermittent fevers, cachexia, myalgias, arthralgias, and respiratory symptoms. Through subsequent investigations, the patient was ultimately diagnosed with congenitally acquired immunodeficiency syndrome (AIDS.

  14. Development and current state of dosimetry in Cuba

    International Nuclear Information System (INIS)

    Prieto Miranda, E.F.; Cuesta Fuente, G.; Chavez Ardanza, A.

    1999-01-01

    In Cuba, the application of the radiation technologies has been growing in the last years, and at present there are several dosimetry systems with different ranges of absorbed dose. Diverse researches were carried out on high dose dosimetry with the following dosimetry systems: Fricke, ceric-cerous sulfate, ethanol-chlorobenzene, cupric sulfate and Perspex (Red 4034 AE and Clear HX). In this paper the development achieved during the last 15 years in the high dose dosimetry for radiation processing in Cuba is presented, as well as, the current state of different dosimetry systems employed for standardization and for process control. The paper also reports the results of dosimetry intercomparison studies that were performed with the Ezeiza Atomic Center of Argentine and the International Dose Assurance Service (IDAS) of IAEA. (author)

  15. BeOSL system for personal dosimetry : dosimetric characteristics and practical application; Sistema BeOSL para dosimetria personal : caracteristicas dosimetricas y la aplicacion practica

    Energy Technology Data Exchange (ETDEWEB)

    Mende, E. [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, Working Group Engineering, D-85764 Neuherberg (Germany)

    2015-10-15

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  16. Study on dosimetry systems for a few tens MeV/u ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Takuji; Sunaga, Hiromi; Takizawa, Haruki; Tachibana, Hiroyuki [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A combined measurement system consisting of a total calorimeter, a Faraday cup and thin film dosimeters have been developed and tested using a simultaneous irradiation apparatus to measure absorbed dose for a few tens MeV/u ion beams of the TIARA AVF cyclotron. (author)

  17. Glycerol-3-phosphate metabolism in wheat contributes to systemic acquired resistance against Puccinia striiformis f. sp. tritici.

    Directory of Open Access Journals (Sweden)

    Yuheng Yang

    Full Text Available Glycerol-3-phosphate (G3P is a proposed regulator of plant defense signaling in basal resistance and systemic acquired resistance (SAR. The GLY1-encoded glycerol-3-phosphate dehydrogenase (G3PDH and GLI1-encoded glycerol kinase (GK are two key enzymes involved in the G3P biosynthesis in plants. However, their physiological importance in wheat defense against pathogens remains unclear. In this study, quantification analysis revealed that G3P levels were significantly induced in wheat leaves challenged by the avirulent Puccinia striiformis f. sp. tritici (Pst race CYR23. The transcriptional levels of TaGLY1 and TaGLI1 were likewise significantly induced by avirulent Pst infection. Furthermore, knocking down TaGLY1 and TaGLI1 individually or simultaneously with barley stripe mosaic virus-induced gene silencing (BSMV-VIGS inhibited G3P accumulation and compromised the resistance in the wheat cultivar Suwon 11, whereas the accumulation of salicylic acid (SA and the expression of the SA-induced marker gene TaPR1 in plant leaves were altered significantly after gene silencing. These results suggested that G3P contributes to wheat systemic acquired resistance (SAR against stripe rust, and provided evidence that the G3P function as a signaling molecule is conserved in dicots and monocots. Meanwhile, the simultaneous co-silencing of multiple genes by the VIGS system proved to be a powerful tool for multi-gene functional analysis in plants.

  18. ConoSurf: Open-source 3D scanning system based on a conoscopic holography device for acquiring surgical surfaces.

    Science.gov (United States)

    Brudfors, Mikael; García-Vázquez, Verónica; Sesé-Lucio, Begoña; Marinetto, Eugenio; Desco, Manuel; Pascau, Javier

    2017-09-01

    A difficulty in computer-assisted interventions is acquiring the patient's anatomy intraoperatively. Standard modalities have several limitations: low image quality (ultrasound), radiation exposure (computed tomography) or high costs (magnetic resonance imaging). An alternative approach uses a tracked pointer; however, the pointer causes tissue deformation and requires sterilizing. Recent proposals, utilizing a tracked conoscopic holography device, have shown promising results without the previously mentioned drawbacks. We have developed an open-source software system that enables real-time surface scanning using a conoscopic holography device and a wide variety of tracking systems, integrated into pre-existing and well-supported software solutions. The mean target registration error of point measurements was 1.46 mm. For a quick guidance scan, surface reconstruction improved the surface registration error compared with point-set registration. We have presented a system enabling real-time surface scanning using a tracked conoscopic holography device. Results show that it can be useful for acquiring the patient's anatomy during surgery. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery Published by John Wiley & Sons Ltd.

  19. The Hanford Emergency Dosimetry System; Le Systeme de Dosimetrie pour les Cas d'Urgence a Hanford; 0421 0418 0421 0422 0414 ; El Sistema Dosimetrico de Hanford para Casos de Urgencia

    Energy Technology Data Exchange (ETDEWEB)

    Larson, H. V.; Keene, A. R. [Radiation Protection Operation, Hanford Laboratories, General Electric Company, Hanford Atomic Products Operation, Richland, WA (United States)

    1965-06-15

    The Hanford project is a major atomic industrial complex, including nuclear reactors, fuel fabrication plants, chemical separation facilities and research laboratories. In addition to a surveillance and control programme for personnel radiation exposures, an emergency dosimetry system has been developed to provide rapid assessment of high dose rates, identification and control of employees, staff notifications and formation of staff emergency control centres, assessment of external exposure doses, evaluation of body burdens of radioactive materials, detection and control of radioactive environmental contamination and rapid exposure estimates for guidance of rescue and medical personnel. Primary reliance is placed upon the Hanford Film Badge Dosimeter, worn by all persons within controlled areas. The badge provides positive identification of the wearer and the film can be evaluated within 90 min. Separately, yet simultaneously, the remaining components of the badge can be processed for determinations of the neutron spectrum and dose in five energy groups, as well as provide an early estimate of the single collision neutron dose from a few to several thousand rads. Gamma-ray detection ranges from 20 mr to 1500 r from the film components to 10 to 10 000 r from tantalum shielded fluorods. The emergency system includes programmes that ensure employee understanding, monitor training and management co-operation for fast identification, control and segregation of affected employees. Monitoring personnel, using portable instrumentation, obtain on-site in vivo measurements of Na{sup 24} or measurements of activated indium foil in the film-badge dosimeter for preliminary dose estimates. The staff notification and operation of emergency control centres provide technical guidance and mobile supportive equipment including a mobile whole-body counter. Back-up laboratory facilities give supportive dosimetry through the analysis of blood for Na{sup 24} activation, P{sup 32} hair

  20. Building a graphite calorimetry system for the dosimetry of therapeutic x-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Jung; Kim, Byoung Chul; Kim, Joong Hyun; Chung, Jae Pil; Kim, Hyun Moon; Yi, Chul Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2017-06-15

    A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak). The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit) for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of 0.798 J/μC, 0.389 J/μC, and 0.352 J/μC at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

  1. DOSEXPRT: A bioassay dosimetry code for Martin Marietta Energy Systems, Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Ward, R.C.; Eckerman, K.F.

    1992-04-01

    The bioassay code DOSEXPRT was developed for Martin Marietta Energy Systems, Inc., to provide compliance with Department of Energy (DOE) Order 5480, Chapter 11. DOSEXPRT computes the intake of a radionuclide in any year (considering both acute and chronic intakes) from in vivo measurements of the retained activity and/or measurements of the activity in excreta. The committed effective and organ doses for the intake are computed as well as the effective and organ doses expected to be received in each calendar year out to 50 years beyond the year of intake. The bioassay records used as input for DOSEXPRT are extracted from the Martin Marietta Energy Systems Occupational Health Information System (OHIS). DOSEXPRT implements a set of algorithms with parameters governing the translocation, retention, and excretion of the nuclide contained in data files specific to the nuclide. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent for the intakes in the year. Annual organ and effective doses are computed using additional dose-rate files that contain data on the dose rate at various times following a unit intake. If measurements are presented for more than one assay for a given nuclide, DOSEXPRT estimates the intake by applying weights assigned in the nuclide file for each assay. DOSEXPRT is accessed off the OHIS MENU No. 4 and designed to be run as a batch processor, but can also be run interactively for testing purposes.

  2. DOSEXPRT: A bioassay dosimetry code for Martin Marietta Energy Systems, Inc

    Energy Technology Data Exchange (ETDEWEB)

    Ward, R.C.; Eckerman, K.F.

    1992-04-01

    The bioassay code DOSEXPRT was developed for Martin Marietta Energy Systems, Inc., to provide compliance with Department of Energy (DOE) Order 5480, Chapter 11. DOSEXPRT computes the intake of a radionuclide in any year (considering both acute and chronic intakes) from in vivo measurements of the retained activity and/or measurements of the activity in excreta. The committed effective and organ doses for the intake are computed as well as the effective and organ doses expected to be received in each calendar year out to 50 years beyond the year of intake. The bioassay records used as input for DOSEXPRT are extracted from the Martin Marietta Energy Systems Occupational Health Information System (OHIS). DOSEXPRT implements a set of algorithms with parameters governing the translocation, retention, and excretion of the nuclide contained in data files specific to the nuclide. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent for the intakes in the year. Annual organ and effective doses are computed using additional dose-rate files that contain data on the dose rate at various times following a unit intake. If measurements are presented for more than one assay for a given nuclide, DOSEXPRT estimates the intake by applying weights assigned in the nuclide file for each assay. DOSEXPRT is accessed off the OHIS MENU No. 4 and designed to be run as a batch processor, but can also be run interactively for testing purposes.

  3. Detection of transgenerational spermatogenic inheritance of adult male acquired CNS gene expression characteristics using a Drosophila systems model.

    Directory of Open Access Journals (Sweden)

    Abhay Sharma

    Full Text Available Available instances of inheritance of epigenetic transgenerational phenotype are limited to environmental exposures during embryonic and adult gonadal development. Adult exposures can also affect gametogenesis and thereby potentially result in reprogramming of the germline. Although examples of epigenetic effects on gametogenesis exist, it is notable that transgenerational inheritance of environment-induced adult phenotype has not yet been reported. Epigenetic codes are considered to be critical in neural plasticity. A Drosophila systems model of pentylenetetrazole (PTZ induced long-term brain plasticity has recently been described. In this model, chronic PTZ treatment of adult males causes alterations in CNS transcriptome. Here, we describe our search for transgenerational spermatogenic inheritance of PTZ induced gene expression phenotype acquired by adult Drosophila males. We generated CNS transcriptomic profiles of F(1 adults after treating F(0 adult males with PTZ and of F(2 adults resulting from a cross between F(1 males and normal females. Surprisingly, microarray clustering showed F(1 male profile as closest to F(1 female and F(0 male profile closest to F(2 male. Differentially expressed genes in F(1 males, F(1 females and F(2 males showed significant overlap with those caused by PTZ. Interestingly, microarray evidence also led to the identification of upregulated rRNA in F(2 males. Next, we generated microarray expression profiles of adult testis from F(0 and F(1 males. Further surprising, clustering of CNS and testis profiles and matching of differentially expressed genes in them provided evidence of a spermatogenic mechanism in the transgenerational effect observed. To our knowledge, we report for the first time detection of transgenerational spermatogenic inheritance of adult acquired somatic gene expression characteristic. The Drosophila systems model offers an excellent opportunity to understand the epigenetic mechanisms underlying

  4. Detection of transgenerational spermatogenic inheritance of adult male acquired CNS gene expression characteristics using a Drosophila systems model.

    Science.gov (United States)

    Sharma, Abhay; Singh, Priyanka

    2009-06-02

    Available instances of inheritance of epigenetic transgenerational phenotype are limited to environmental exposures during embryonic and adult gonadal development. Adult exposures can also affect gametogenesis and thereby potentially result in reprogramming of the germline. Although examples of epigenetic effects on gametogenesis exist, it is notable that transgenerational inheritance of environment-induced adult phenotype has not yet been reported. Epigenetic codes are considered to be critical in neural plasticity. A Drosophila systems model of pentylenetetrazole (PTZ) induced long-term brain plasticity has recently been described. In this model, chronic PTZ treatment of adult males causes alterations in CNS transcriptome. Here, we describe our search for transgenerational spermatogenic inheritance of PTZ induced gene expression phenotype acquired by adult Drosophila males. We generated CNS transcriptomic profiles of F(1) adults after treating F(0) adult males with PTZ and of F(2) adults resulting from a cross between F(1) males and normal females. Surprisingly, microarray clustering showed F(1) male profile as closest to F(1) female and F(0) male profile closest to F(2) male. Differentially expressed genes in F(1) males, F(1) females and F(2) males showed significant overlap with those caused by PTZ. Interestingly, microarray evidence also led to the identification of upregulated rRNA in F(2) males. Next, we generated microarray expression profiles of adult testis from F(0) and F(1) males. Further surprising, clustering of CNS and testis profiles and matching of differentially expressed genes in them provided evidence of a spermatogenic mechanism in the transgenerational effect observed. To our knowledge, we report for the first time detection of transgenerational spermatogenic inheritance of adult acquired somatic gene expression characteristic. The Drosophila systems model offers an excellent opportunity to understand the epigenetic mechanisms underlying the

  5. The personal dosimetry in Mexico

    International Nuclear Information System (INIS)

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  6. A Master-Slave Surveillance System to Acquire Panoramic and Multiscale Videos

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2014-01-01

    Full Text Available This paper describes a master-slave visual surveillance system that uses stationary-dynamic camera assemblies to achieve wide field of view and selective focus of interest. In this system, the fish-eye panoramic camera is capable of monitoring a large area, and the PTZ dome camera has high mobility and zoom ability. In order to achieve the precise interaction, preprocessing spatial calibration between these two cameras is required. This paper introduces a novel calibration approach to automatically calculate a transformation matrix model between two coordinate systems by matching feature points. In addition, a distortion correction method based on Midpoint Circle Algorithm is proposed to handle obvious horizontal distortion in the captured panoramic image. Experimental results using realistic scenes have demonstrated the efficiency and applicability of the system with real-time surveillance.

  7. Dosimetry optimization at COGEMA-La Hague

    International Nuclear Information System (INIS)

    Kalimbadjian, J.

    2000-01-01

    At the present time, the la Hague site strives to apply international recommendations together with national regulations concerning radiation protection, and especially the respect of limitation and optimization principles. The application of these principles is based on the implementation of a passive dosimetry and an active dosimetry. The monthly passive dosimetry is monitored by means of a photographic dosimetry film, completed with lithium fluorine thermoluminescent film badges. This personal dosimetry common to X, β, γ and neutron radiations is carried out in close relationship between the Radiation Protection Department, the Occupational Medical Department and the staff running the Plant. The application or ALARA's principle as well as that of radiation protection optimization implies to implement a complementary active dosimetry enabling to gain in real time, the personal dosimetry of each intervening person, either they be COGEMA's workers or external companies'. This active dosimetry provides with following information: This preventive dosimetry is based on the knowledge of doses integration in real time and is fitted with alarm thresholds according to the total amount of doses and dose rates. Thresholds on the dose rate are also set relatively to the radiological environment. This knowledge of doses and dose rates allows a stricter management of the works, while analyzing them according to the nature of the work, to the location and to the skills of the intervening people. This dosimetry allows to analyze and optimize doses integration according to the works nature for the whole intervening staff. The la Hague Site has developed an active personal dosimetry system, common to every intervening person, COGEMA or external companies. The DOSICARD was thus elaborated, shaped as an electronic dosimeter fitted with an alarm and a smart card. The access to controlled areas is conditioned to information given by the DOSICARD concerning medical aptitudes and

  8. Photoirradiation system with depth optical dosimetry control in initial oxygen saturation measurement

    International Nuclear Information System (INIS)

    Quintanar, L.; Stolik, S.; Rosa, J. de la; Moreno, E.

    2012-01-01

    Photodynamic Therapy is a technique in which a photosensitizing substance is applied that is activated by light and it generates reactive oxygen species which cause selective cell destruction. The efficiency of the therapy is affected by the parameters dose. In this work it is shown a photo-irradiation system for superficial Photodynamic Therapy, using as a light source a light emitting diode with an automatic control of optical power based on a model of the distribution of light in depth that was tested in tissue phantoms. It also has a reflective pulse oximeter for the measurement of the initial oxygen saturation. (Author)

  9. Radon exposure system for mammalian cells in culture: Design, operation, and dosimetry

    International Nuclear Information System (INIS)

    Seed, T.M.; Kretz, N.D.; Schlenker, R.A.

    1991-01-01

    A novel system for Rn gas exposure of mammalian cells in culture has been designed, constructed, and used to directly assess both the magnitude and the nature of chronic, low-dose Rn/Rn daughter toxicity of exposed vital lung cells isolated from normal pulmonary tissue, propagated and exposed in vitro. Direct correlations between atmospheric Rn concentrations, alpha-particle fluences, and macro- and microdoses of absorbed radiation doses by lung cells provide for a heretofore unavailable assessment of critical doses to vital cells

  10. Building a Graphite Calorimetry System for the Dosimetry of Therapeutic X-ray Beams

    Directory of Open Access Journals (Sweden)

    In Jung Kim

    2017-06-01

    Full Text Available A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak. The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of 0.798 J/μC, 0.389 J/μC, and 0.352 J/μC at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

  11. Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Righetto, Roberto; Cavedon, Carlo; Francescon, Paolo; Colombo, Federico

    2010-01-01

    Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of

  12. Quality Control in the Dosimetric System of the Personnel Dosimetry Service of the Spanish National Health Service

    Energy Technology Data Exchange (ETDEWEB)

    Casal, E.; Gil, J.A.; Roig, F.; Soriano, A. [Valencia (Spain)

    1999-07-01

    The main operating and quality control procedures implemented at the Centro Nacional de Dosimetria (CND) of the Spanish National Health Service to ensure the acceptance of the dosimetry service are described. The operating procedures are routinely performed at every step, since the dosemeters are received from the manufacturer until the doses are assigned to the dosimetric history and their main aim is to ensure the traceability of the doses. They make use of control and background dosemeters and frequent cross reference (automatic and manual) of different sources of data. The control procedures are performed at the end of each monthly process to detect possible errors or systematic bias in the dosimetry service and include analysis of the measurements of quality control dosemeters irradiated at the CND's laboratory and randomly read. The results of this analysis since 1996 are presented. (author)

  13. Quality Control in the Dosimetric System of the Personnel Dosimetry Service of the Spanish National Health Service

    International Nuclear Information System (INIS)

    Casal, E.; Gil, J.A.; Roig, F.; Soriano, A.

    1999-01-01

    The main operating and quality control procedures implemented at the Centro Nacional de Dosimetria (CND) of the Spanish National Health Service to ensure the acceptance of the dosimetry service are described. The operating procedures are routinely performed at every step, since the dosemeters are received from the manufacturer until the doses are assigned to the dosimetric history and their main aim is to ensure the traceability of the doses. They make use of control and background dosemeters and frequent cross reference (automatic and manual) of different sources of data. The control procedures are performed at the end of each monthly process to detect possible errors or systematic bias in the dosimetry service and include analysis of the measurements of quality control dosemeters irradiated at the CND's laboratory and randomly read. The results of this analysis since 1996 are presented. (author)

  14. Application of the TWODANT code system to pressure vessel dosimetry calculations

    International Nuclear Information System (INIS)

    Parsons, D.K.; Alcouffe, R.E.; Marr, D.R.; Urban, W.T.

    1993-01-01

    The TWODANT code system has recently been enhanced to include TWODANT/GQ and THREEDANT. TWODANT/GQ solves the two-dimensional form of the discrete ordinates approximation to the transport equation on a generalized quadrilateral mesh. This geometric capability is very general and allows nearly exact representations of X-Y or R-Z geometries. THREEDANT solves the three-dimensional form of the discrete ordinates equations. In addition to the conventional coarse-mesh material zone input, THREEDANT can also be linked to a three-dimensional nested-region mesh generation code called FRAC-IN-THE-BOX. THREEDANT can thus model a much wider variety of geometric shapes than any other discrete ordinates code. These enhanced geometric modeling capabilities are applied here to the analysis of the VENUS PWR Mock-Up Facility

  15. A portable system for acquiring and removing motion artefact from ECG signals

    Science.gov (United States)

    Griffiths, A.; Das, A.; Fernandes, B.; Gaydecki, P.

    2007-07-01

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview ® interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the vest.

  16. A portable system for acquiring and removing motion artefact from ECG signals

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, A; Das, A; Fernandes, B; Gaydecki, P [School of Electrical and Electronic Engineering, University of Manchester, PO Box 88, Manchester M60 1QD (United Kingdom)

    2007-07-15

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview (registered) interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the ves000.

  17. An IAEA Survey of Dosimetry Audit Networks for Radiotherapy

    International Nuclear Information System (INIS)

    Grochowska, Paulina; Izewska, Joanna

    2013-01-01

    A Survey: In 2010, the IAEA undertook a task to investigate and review the coverage and operations of national and international dosimetry audit programmes for radiotherapy. The aim was to organize the global database describing the activities of dosimetry audit networks in radiotherapy. A dosimetry audit questionnaire has been designed at an IAEA consultants' meeting held in 2010 for organizations conducting various levels of dosimetry audits for radiotherapy. Using this questionnaire, a survey was conducted for the first time in 2010 and repeated in 2011. Request for information on different aspects of the dosimetry audit was included, such as the audit framework and resources, its coverage and scope, the dosimetry system used and the modes of audit operation, i.e. remotely and through on-site visits. The IAEA questionnaire was sent to over 80 organizations, members of the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories (SSDLs) and other organizations known for having operated dosimetry audits for radiotherapy in their countries or internationally. Survey results and discussion: In response to the IAEA survey, 53 organizations in 45 countries confirmed that they operate dosimetry audit services for radiotherapy. Mostly, audits are conducted nationally, however there are five organizations offering audits abroad, with two of them operating in various parts of the world and three of them at the regional level, auditing radiotherapy centres in neighbouring countries. The distribution of dosimetry audit services in the world is given. (author)

  18. Dosimetry of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez C, G; Restrepo, J; Aguirre, C A [Hospital Universitario del Valle, Cali (Colombia)

    1996-08-01

    The systemic therapy of breast cancer has also changed profoundly during the last 60 years, and in this time the integration of treatment modalities involve a major area of investigation. The dosimetry of breast cancer presents different complications which can range from the Physician`s handling of the neoplasia up to the simple aspects of physical simulation, contour design, radiation fields, irregular surfaces and computer programs containing mathematical equations which differ little or largely with the reality of the radiation distribution into the volume to be irradiated. We have studied the problem using two types of measurements to determine how the radiation distribution is in irregular surfaces, and designing an easier skill to be used with each patient, in order to optimize the treatment with respect to the simulation and verification process. (author). 7 refs.

  19. Nervous system manifestations and neuroradiologic findings in acquired immunodeficiency syndrome (AIDS)

    International Nuclear Information System (INIS)

    Rodesch, G.; Parizel, P.M.; Lalmand, B.; Vanderhofstadt, A.; Baleriaux, D.; Farber, C.M.; Calck, M. van; Przedborski, S.; Haens, J. d'; Taelman, H.

    1989-01-01

    We report a series of thirteen patients with nervous system complications out of a total of thirty AIDS patients admitted to our hospital over the last two years for which CT and/or MRI have been performed. Five were homosexual men and eight patients (5 men, 3 women) were of African origin (Zaire and Rwanda) (n=5) or had had sexual intercourse with the local African population (n=3). The nervous system complications encountered included: Toxoplasma gondii brain abscess (2 patients); cryptococcus neoformans meningitis+toxoplasmosis (1 patient); toxoplasmosis+lymphoma (2 patients); progressive multifocal leucoencephalopathy (1 patient); lymphocytic meningitis or encephalitis (3 patients); lymphoma (1 patient); polyradiculoneuritis (3 patients). Three of thirteen patients had multiple intracranial abnormalities: One had concomitant intraparenchymal toxoplasma abscess and cryptococcal meningitis; in one patient a lymphoma developed after the successful medical treatment of a toxoplasma abscess; conversely, one patient developed a toxoplasma abscess two years after mediastinal radiotherapy for a systemic non-Hodgkin lymphoma. In conclusion, in our experience, nervous system toxoplasmosis is the most frequent AIDS related CNS complication. Our series demonstrates the high frequency of a second neurological disease occurring either concomitantly or separately. In these cases, while CT may readily identify the intracranial abnormalities, it contributes little towards an etiological diagnosis. Finally, our series illustrates the importance of a central African endemic focus for AIDS. (orig.)

  20. Nervous system manifestations and neuroradiologic findings in acquired immunodeficiency syndrome (AIDS)

    Energy Technology Data Exchange (ETDEWEB)

    Rodesch, G.; Parizel, P.M.; Lalmand, B.; Vanderhofstadt, A.; Baleriaux, D.; Farber, C.M.; Calck, M. van; Przedborski, S.; Haens, J. d' ; Taelman, H.

    1989-03-01

    We report a series of thirteen patients with nervous system complications out of a total of thirty AIDS patients admitted to our hospital over the last two years for which CT and/or MRI have been performed. Five were homosexual men and eight patients (5 men, 3 women) were of African origin (Zaire and Rwanda) (n=5) or had had sexual intercourse with the local African population (n=3). The nervous system complications encountered included: Toxoplasma gondii brain abscess (2 patients); cryptococcus neoformans meningitis+toxoplasmosis (1 patient); toxoplasmosis+lymphoma (2 patients); progressive multifocal leucoencephalopathy (1 patient); lymphocytic meningitis or encephalitis (3 patients); lymphoma (1 patient); polyradiculoneuritis (3 patients). Three of thirteen patients had multiple intracranial abnormalities: One had concomitant intraparenchymal toxoplasma abscess and cryptococcal meningitis; in one patient a lymphoma developed after the successful medical treatment of a toxoplasma abscess; conversely, one patient developed a toxoplasma abscess two years after mediastinal radiotherapy for a systemic non-Hodgkin lymphoma. In conclusion, in our experience, nervous system toxoplasmosis is the most frequent AIDS related CNS complication. Our series demonstrates the high frequency of a second neurological disease occurring either concomitantly or separately. In these cases, while CT may readily identify the intracranial abnormalities, it contributes little towards an etiological diagnosis. Finally, our series illustrates the importance of a central African endemic focus for AIDS.

  1. Online patient dosimetry and an image quality audit system in digital radiology; Auditoria en tiempo real de dosis a los pacientes y claidad de imagen en radiologia digital

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J. M.; Vano, E.; Ten, J. I.; Prieto, C.; Martinez, D.

    2006-07-01

    The present work describes an online patient dosimetry and an image quality audit system in digital radiology. the system allows auditing of different parameters depending on contents of DICOM (Digital Imaging and Communication in Medicine) header. For the patient dosimetry audit, current mean values of entrance surface dose (ESD) were compared with local and national reference values (RVs) for the specific examination type evaluated. Mean values exceeding the RV trigger an alarm signal and then an evaluation of the technical parameters, operational practice and image quality starts, using data available in the DICOM header to derive any abnormal settings or performance to obtain the image. the X-ray tube output for different kVp values is measured periodically, allowing for the automatic calculation of the ESD. The system also allows for image quality audit linking it with the dose imparted and other technical parameters if the alarm condition if produced. Results and advantages derived from this online quality control are discussed. (Author) 5 refs.

  2. Biodistribution and human dosimetry estimation of fluoro-L-DOPA as PET imaging agent of dopaminergic nerve transmitter systems

    International Nuclear Information System (INIS)

    Tang Ganghua; Wang Mingfang; Luo Lei; Gan Manquan; Tang Xiaolan; Zhang Lan; Wang Yongxian

    2002-01-01

    Objective: To investigate the biodistribution and human dosimetry estimation of 6-[ 18 F] Fluoro-L-DOPA (FDOPA). Methods: Biodistribution of FDOPA in normal rats and brain of hemi-Parkinsonism rats were determined. Human dosimetry estimation was performed by MIRD method based on the rats biodistribution data. Results: Biodistributions in normal rats showed high uptake in kidney, blood, striatum and hippocampi, fast clearance of radioactivity from kidney and blood, longer retain time in striatum and hippocampi, and higher striatum to cerebellum and striatum to cortex ratio. FDOPA uptake, striatum to cerebellum and striatum to cortex ratio in the lesioned side of hemi-Parkinsonism rats (P 2 to 2.3 x 10 -2 mGy/MBq and the effective dose in humans was estimated to be 2.05 x 10 -2 mSv/MBq after injection of FDOPA based on rats biodistribution data, which were consistent with those reported by literature on the whole. Conclusion: Human radiation dosimetry of FDOPA and other PET tracers can be estimated based on animals biodistribution data. The synthetic FDOPA is safe and efficient and can be used in animals, human and PD patients PET studies

  3. A new label dosimetry system based on pentacosa-diynoic acid monomer for low dose applications

    International Nuclear Information System (INIS)

    Abdel-Fattah, A.A.; Abdel-Rehim, F.; Soliman, Y.S.

    2012-01-01

    The dosimetric characteristics of γ-radiation sensitive labels based on polyvinyl butyral (PVB) and a conjugated diacetylene monomer, 10,12-pentacosa-diynoic acid (PCDA) have been investigated using reflectance colorimeter. Two types of labels (colourless and yellow) based on PCDA monomer were prepared using an Automatic Film Applicator System. Upon γ-ray exposure, the colourless label turns progressively blue, while the yellow colour label turns to green then to dark blue. The colour intensity of the labels is proportional to the radiation absorbed dose. The useful dose range was 15 Gy-2 kGy depending on PCDA monomer concentration. The expanded uncertainty of dose measurement of the colourless label was 6.06 (2σ). - Highlights: → Using 10,12-pentacosa-diynoic acid (PCDA) in preparation of label dosimeter. → PCDA polymerises upon γ-rays exposure producing a blue coloured polymer. → Useful dose range is 15 Gy to 2 kGy depending on concentration of PCDA. → Overall uncertainty of label dosimeter was 6.06 at 2σ.

  4. A new label dosimetry system based on pentacosa-diynoic acid monomer for low dose applications

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Fattah, A.A.; Abdel-Rehim, F. [National Center for Radiation Research and Technology, Atomic Energy Authority, P.O. Box 8029, Nasr City, Cairo (Egypt); Soliman, Y.S., E-mail: yasser_shabaan@hotmail.com [National Center for Radiation Research and Technology, Atomic Energy Authority, P.O. Box 8029, Nasr City, Cairo (Egypt)

    2012-01-15

    The dosimetric characteristics of {gamma}-radiation sensitive labels based on polyvinyl butyral (PVB) and a conjugated diacetylene monomer, 10,12-pentacosa-diynoic acid (PCDA) have been investigated using reflectance colorimeter. Two types of labels (colourless and yellow) based on PCDA monomer were prepared using an Automatic Film Applicator System. Upon {gamma}-ray exposure, the colourless label turns progressively blue, while the yellow colour label turns to green then to dark blue. The colour intensity of the labels is proportional to the radiation absorbed dose. The useful dose range was 15 Gy-2 kGy depending on PCDA monomer concentration. The expanded uncertainty of dose measurement of the colourless label was 6.06 (2{sigma}). - Highlights: > Using 10,12-pentacosa-diynoic acid (PCDA) in preparation of label dosimeter. > PCDA polymerises upon {gamma}-rays exposure producing a blue coloured polymer. > Useful dose range is 15 Gy to 2 kGy depending on concentration of PCDA. > Overall uncertainty of label dosimeter was 6.06 at 2{sigma}.

  5. Theoretical thermal dosimetry produced by an annular phased array system in CT-based patient models

    International Nuclear Information System (INIS)

    Paulsen, K.D.; Strohbehn, J.W.; Lynch, D.R.

    1984-01-01

    Theoretical calculations for the specific absorption rate (SAR) and the resulting temperature distributions produced by an annular phased array (APA) type system are made. The finite element numerical method is used in the formulation of both the electromagnetic (EM) and the thermal boundary value problems. A number of detailed patient models based on CT-scan data from the pelvic, visceral, and thoracic regions are generated to stimulate a variety of tumor locations and surrounding normal tissues. The SAR values from the EM solution are input into the bioheat transfer equation, and steady-rate temperature distributions are calculated for a wide variety of blood flow rates. Based on theoretical modeling, the APA shows no preferential heating of superficial over deep-seated tumors. However, in most cases satisfactory thermal profiles (therapeutic volume near 60%) are obtained in all three regions of the human trunk only for tumors with little or no blood flow. Unsatisfactory temperature patterns (therapeutic volume <50%) are found for tumors with moderate to high perfusion rates. These theoretical calculations should aid the clinician in the evaluation of the effectiveness of APA type devices in heating tumors located in the trunk region

  6. Chromosome painting in biological dosimetry: Semi-automatic system to score stable chromosome aberrations

    International Nuclear Information System (INIS)

    Garcia-Sagredo, J.M.; Vallcorba, I.; Sanchez-Hombre, M.C.; Ferro, M.T.; San Roman Cos-Gayon, C.; Santos, A.; Malpica, N.; Ortiz, C.

    1997-01-01

    From the beginning of the description of the procedure of chromosome painting by fluorescence in situ hybridization (FISH), it was thought its possible application to score induced chromosomal aberrations in radiation exposition. With chromosome painting it is possible to detect changes between chromosomes that has been validated in radiation exposition. Translocation scoring by FISH, contrarily to the unstable dicentrics, mainly detect stable chromosome aberrations that do not disappear, it allows the capability of quantify delayed acute expositions or chronic cumulative expositions. The large number of cells that have to be analyzed for high accuracy, specially when dealing with low radiation doses, makes it almost imperative to use an automatic analysis system. After validate translocation scoring by FISH in our, we have evaluated the ability and sensitivity to detect chromosomal aberrations by chromosome using different paint probes used, showing that any combination of paint probes can be used to score induced chromosomal aberrations. Our group has developed a FISH analysis that is currently being adapted for translocation scoring analysis. It includes systematic error correction and internal control probes. The performance tests carried out show that 9,000 cells can be analyzed in 10 hr. using a Sparc 4/370. Although with a faster computer, a higher throughput is expected, for large population screening or very low radiation doses, this performance still has to be improved. (author)

  7. Development of dose calibrators Tandem systems and establishment of beta dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Cecatti, Sonia Garcia Pereira

    2004-01-01

    A quality control program at Nuclear Medicine Services includes the checking of all equipment used for diagnostics and treatment, and the individual monitoring of the workers occupationally exposed to ionizing radiations. In this work the main quality control tests were performed with three dose calibrators using standard radiation sources of 57 Co, 133 Ba, 137 Cs and 60 Co. Tandem systems of dose calibrators were established and characterized using four cylindrical absorbers of different materials for an additional quality control test in Nuclear Medicine. The main utility of this new test is the possibility of impurity detection in radiopharmaceuticals, when the ratio of the measurements with different absorbers is different from that obtained at the laboratory in ideal conditions. The dosimetric characteristics of three types of CaS0 4 :Dy + Teflon pellets were studied for an appropriate choice of the material to be used for individual monitoring of workers. The thermoluminescent detectors were irradiated using beta sources of 90 Sr+ 90 Y, 204 TI, 147 Pm, 153 Sm and 32 P. A wrist badge for beta individual monitoring was developed for workers that handle beta radiopharmaceuticals in Nuclear Medicine Services. (author)

  8. Nuclear accident dosimetry

    International Nuclear Information System (INIS)

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  9. Personal dosimetry in Kazakhstan

    International Nuclear Information System (INIS)

    Khvoshnyanskaya, I.R.; Vdovichenko, V.G.; Lozbin, A.Yu.

    2003-01-01

    KATEP-AE Radiation Laboratory is the first organization in Kazakhstan officially licensed by the Kazakhstan Atomic Energy Committee to provide individual dosimetry services. The Laboratory was established according to the international standards. Nowadays it is the largest company providing personal dosimetry services in the Republic of Kazakhstan. (author)

  10. Nuclear accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  11. Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA.

    Science.gov (United States)

    Hillman, Yair; Kim, Josh; Chetty, Indrin; Wen, Ning

    2018-04-01

    Mobius 3D (M3D) provides a volumetric dose verification of the treatment planning system's calculated dose using an independent beam model and a collapsed cone convolution superposition algorithm. However, there is a lack of investigation into M3D's accuracy and effectiveness for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) quality assurance (QA). Here, we collaborated with the vendor to develop a revised M3D beam model for SRS/SBRT cases treated with a 6X flattening filter-free (FFF) beam and high-definition multiple leaf collimator (HDMLC) on an Edge linear accelerator. Eighty SRS/SBRT cases, planned with AAA dose algorithm and validated with Gafchromic film, were compared to M3D dose calculations using 3D gamma analysis with 2%/2 mm gamma criteria and a 10% threshold. A revised beam model was developed by refining the HD-MLC model in M3D to improve small field dose calculation accuracy and beam profile agreement. All cases were reanalyzed using the revised beam model. The impact of heterogeneity corrections for lung cases was investigated by applying lung density overrides to five cases. For the standard and revised beam models, respectively, the mean gamma passing rates were 94.6% [standard deviation (SD): 6.1%] and 98.0% [SD: 1.7%] (for the overall patient), 88.2% [SD: 17.3%] and 93.8% [SD: 6.8%] (for the brain PTV), 71.4% [SD: 18.4%] and 81.5% [SD: 14.3%] (for the lung PTV), 83.3% [SD: 16.7%] and 67.9% [SD: 23.0%] (for the spine PTV), and 78.6% [SD: 14.0%] and 86.8% [SD: 12.5%] (for the PTV of all other sites). The lung PTV mean gamma passing rates improved from 74.1% [SD: 7.5%] to 89.3% [SD: 7.2%] with the lung density overridden. The revised beam model achieved an output factor within 3% of plastic scintillator measurements for 2 × 2 cm 2 MLC field size, but larger discrepancies are still seen for smaller field sizes which necessitate further improvement of the beam model. Special attention needs to be paid to small field

  12. 100 years of solid state dosimetry and radiation protection dosimetry

    International Nuclear Information System (INIS)

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  13. An assessment of a 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT.

    Science.gov (United States)

    Stevens, S; Dvorak, P; Spevacek, V; Pilarova, K; Bray-Parry, M; Gesner, J; Richmond, A

    2018-01-01

    To provide a 3D dosimetric evaluation of a commercial portal dosimetry system using 2D/3D detectors under ideal conditions using VMAT. A 2D ion chamber array, radiochromic film and gel dosimeter were utilised to provide a dosimetric evaluation of transit phantom and pre-treatment 'fluence' EPID back-projected dose distributions for a standard VMAT plan. In-house 2D and 3D gamma methods compared pass statistics relative to each dosimeter and TPS dose distributions. Fluence mode and transit EPID dose distributions back-projected onto phantom geometry produced 2D gamma pass rates in excess of 97% relative to other tested detectors and exported TPS dose planes when a 3%, 3 mm global gamma criterion was applied. Use of a gel dosimeter within a glass vial allowed comparison of measured 3D dose distributions versus EPID 3D dose and TPS calculated distributions. 3D gamma comparisons between modalities at 3%, 3 mm gave pass rates in excess of 92%. Use of fluence mode was indicative of transit results under ideal conditions with slightly reduced dose definition. 3D EPID back projected dose distributions were validated against detectors in both 2D and 3D. Cross validation of transit dose delivered to a patient is limited due to reasons of practicality and the tests presented are recommended as a guideline for 3D EPID dosimetry commissioning; allowing direct comparison between detector, TPS, fluence and transit modes. The results indicate achievable gamma scores for a complex VMAT plan in a homogenous phantom geometry and contributes to growing experience of 3D EPID dosimetry. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Boyd, A.W.; Chadwick, K.H.; McDonald, J.C.; Miller, A.

    1989-01-01

    Radiation processing is a relatively young industry with broad applications and considerable commercial success. Dosimetry provides an independent and effective way of developing and controlling many industrial processes. In the sterilization of medical devices and in food irradiation, where the radiation treatment impacts directly on public health, the measurements of dose provide the official means of regulating and approving its use. In this respect, dosimetry provides the operator with a means of characterizing the facility, of proving that products are treated within acceptable dose limits and of controlling the routine operation. This book presents an up-to-date review of the theory, data and measurement techniques for radiation processing dosimetry in a practical and useful way. It is hoped that this book will lead to improved measurement procedures, more accurate and precise dosimetry and a greater appreciation of the necessity of dosimetry for radiation processing. (author)

  15. Some aspects on neutron dosimetry

    International Nuclear Information System (INIS)

    Henaish, B.A.; Youssef, S.K.

    1988-01-01

    The American National Council on Radiation Protection and measurements (1) has recently issued a statement regarding dose limitation system for neutrons. The changes proposed in that statement presented substantial problems regarding the personnel exposure to neutrons and had pointed out the need to reassess an adequate current neutron dosimetry practice. Generally, the same types of dosimeters i.e. Nuclear Track (NTA films) and TLD-Albedo, have been used at major nuclear facilities over the past 15 years. here recently, other dosimetry methods such as track etch with polycarbonates such as CR-39 have been developed. However these should be recognized as local systems aiming to the development of better and more applicable dosimeters. 4 tab

  16. Management system of personnel dosimetry based on ISO 9001:2008 for medical diagnostic; Sistema de gerenciamento da dosimetria pessoal baseado na ISO 9001:2008 para radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Carlos E.B.; Gerber Junior, Walmoli; Jahn, Tiago R.; Hahn, Tiago T.; Fontana, Thiago S.; Bolzan, Vagner, E-mail: brasilrad@brasilrad.com.br [Brasilrad Consultoria em Radioprotecao, Florianopolis, SC (Brazil)

    2013-07-01

    MDose is a computer management system of personal dosimetry in diagnostic radiology services physician based on ISO 9001:9008 management system. According to Brazilian law all service radiology should implement a control of personal dosimetry in addition to radiation doses greater than 1.5 mSv/year service should do research of high dose, which is to identify the causes the resulting dose increase professional. This work is based on the use of the PDCA cycle in a JAVA software developed as a management method in the analysis of high doses in order to promote systematic and continuous improvement within the organization of radiological protection of workers.

  17. Digital system for acquiring signals from photodiode arrays. No. Program Element 2317-08-03

    International Nuclear Information System (INIS)

    Le Guen, M.; Meric, B.

    1981-01-01

    A model of circuit allowing the digitization and the memorization of signals coming from linear arrays of photodiodes have been realized. The authors first recall the organization and present in the second part some test results on experimental sites. The model consists of 1 - an acquisition, memorization and visualization card (AMV card) for the data from RETICON 121 photodiode strips, 2 - a series transfer card for the memorized data, and 3 - an interface and multiplexing card associated with a system using a 6800 microprocessor allowing the management of eight acquisition cards [fr

  18. Study on excitation and fluorescence spectrums of Japanese citruses to construct machine vision systems for acquiring fluorescent images

    Science.gov (United States)

    Momin, Md. Abdul; Kondo, Naoshi; Kuramoto, Makoto; Ogawa, Yuichi; Shigi, Tomoo

    2011-06-01

    Research was conducted to acquire knowledge of the ultraviolet and visible spectrums from 300 -800 nm of some common varieties of Japanese citrus, to investigate the best wave-lengths for fluorescence excitation and the resulting fluorescence wave-lengths and to provide a scientific background for the best quality fluorescent imaging technique for detecting surface defects of citrus. A Hitachi U-4000 PC-based microprocessor controlled spectrophotometer was used to measure the absorption spectrum and a Hitachi F-4500 spectrophotometer was used for the fluorescence and excitation spectrums. We analyzed the spectrums and the selected varieties of citrus were categorized into four groups of known fluorescence level, namely strong, medium, weak and no fluorescence.The level of fluorescence of each variety was also examined by using machine vision system. We found that around 340-380 nm LEDs or UV lamps are appropriate as lighting devices for acquiring the best quality fluorescent image of the citrus varieties to examine their fluorescence intensity. Therefore an image acquisition device was constructed with three different lighting panels with UV LED at peak 365 nm, Blacklight blue lamps (BLB) peak at 350 nm and UV-B lamps at peak 306 nm. The results from fluorescent images also revealed that the findings of the measured spectrums worked properly and can be used for practical applications such as for detecting rotten, injured or damaged parts of a wide variety of citrus.

  19. Dosimetry for electron beam sterilization

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    According to ISO 11137-1 (sect 4.3.4) dosimetry used in the development, validation and routine control of the sterilization process shall have measurement traceability to national or international standards and shall have a known level of uncertainty. It can only be obtained through calibration of the dosimeters. In presented lecture different types of dosimeter systems for electron beams (calorimeters, radiochromic film dosimeters, alanine / EPR) and their calibration are described

  20. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    International Nuclear Information System (INIS)

    Rathbone, Bruce A.

    2006-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL's Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL's Electronic Records & Information Capture Architecture (ERICA) database

  1. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2005-02-25

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database.

  2. Dosimetry and operation of irradiation facilities

    International Nuclear Information System (INIS)

    Vidal, P.E.

    1985-01-01

    The industrial use of ionizing radiation has required, from the very first, the measurement of delivered and absorbed doses; hence the necessity of providing dosimetric systems. Laboratories, scientists, industries and potential equipment manufacturers have all collaborated in this new field of activity. Dosimetric intercomparisons have been made by each industry at their own facilities and in collaboration with specialists, national organizations and the IAEA. Dosimetry has become a way of ensuring that treatment by irradiation has been carried out in accordance with the rules. It has become in effect assurance of quality. Routine dosimetry should determine a maximum and minimum dose. Numerous factors play a part in dosimetry. Industry is currently in possession of routine dosimetric systems that are sufficiently accurate, fairly easy to handle and reasonable in cost, thereby satisfying all the requirements of industry and the need for control. Dosimetry is important in the process of marketing irradiated products. The operator of an industrial irradiation facility bases his dosimetry on comparison with reference systems. Research aimed at simplifying the practice of routine dosimetry should be continued. New physical and chemical techniques will be incorporated into systems already in use. The introduction of microcomputers into the operation of radiation facilities has increased the value of dosimetry and made the conditions of treatment more widespread. Stress should be placed on research in several areas apart from reference systems, for example: dosimetric systems at temperatures from +8 deg. C to -45 deg. C, over the dose range 100 krad to a little more than 1 Mrad, liquids and fluidized solids carried at high speed through ducts, thin-film liquids circulating at a high flow rate, and various other problems. (author)

  3. Characterization of Taurine Transporting Systems During Acquirement of Resistance to Platinum(II)-based, Chemotherapeutic Drugs

    DEFF Research Database (Denmark)

    Sørensen, Belinda Halling

    Although, cisplatin is one of the most effective broad-spectrum anticancer drugs, prolonged cisplatin treatment often results in development of chemoresistance and subsequent therapeutic failure. Dysregulation of the taurine transporting systems i.e., the taurine transporter (TauT) and volume....... Cisplatin resistance correlates with a reduction in the volume regulated anion current and taurine release mediated by VRACs, as well as an improved cellular accumulation of taurine through TauT. In human ovarian A2780 cancer cells, for instance, cisplatin resistance is associated with an absent swelling......-induced taurine release and inability to volume regulate. The dismissed taurine release was due to an almost absent leucin-rich-repeat containing 8A (LRRC8A) total protein expression. LRRC8A is an important component of VRACs. Cellular taurine contributes to the intracellular pool of organic osmolytes. Moreover...

  4. : acquired resistance in mice by implantation of young irradiated worms into the portal system

    Directory of Open Access Journals (Sweden)

    Paulo Marcos Z. Coelho

    1989-02-01

    Full Text Available In two distinct experiments, immature S. mansoni worms (LE strain, Belo Horizonte, Brazil, aged 20 days, obtained from the portal system of white outbred mice, were irradiated with 14 and 4 Krad, respectively. Afterwards, the worms were directly inoculated into the portal vein of normal mice. Inoculation was performed with 20 irradiated worms per animal. Fifty days after inoculation, the mice that received 4 and 14 Krad-irradiated worms and their respective controls were infected with S. mansoni cercariae (LE strain, by transcutaneous route. Twenty days after this challenge infection, the animals were sacrificed and perfused for mature irradiated (90-day-old and immature (20-day-old worm counts. Analysis of the results showed that statistically significant protection against cercariae occurred in both groups with irradiated worms.

  5. Optimizing preoperative blood ordering with data acquired from an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Rothschild, James A; Masear, Courtney G; Rivers, Richard J; Merritt, William T; Savage, Will J; Ness, Paul M

    2013-06-01

    The maximum surgical blood order schedule (MSBOS) is used to determine preoperative blood orders for specific surgical procedures. Because the list was developed in the late 1970s, many new surgical procedures have been introduced and others improved upon, making the original MSBOS obsolete. The authors describe methods to create an updated, institution-specific MSBOS to guide preoperative blood ordering. Blood utilization data for 53,526 patients undergoing 1,632 different surgical procedures were gathered from an anesthesia information management system. A novel algorithm based on previously defined criteria was used to create an MSBOS for each surgical specialty. The economic implications were calculated based on the number of blood orders placed, but not indicated, according to the MSBOS. Among 27,825 surgical cases that did not require preoperative blood orders as determined by the MSBOS, 9,099 (32.7%) had a type and screen, and 2,643 (9.5%) had a crossmatch ordered. Of 4,644 cases determined to require only a type and screen, 1,509 (32.5%) had a type and crossmatch ordered. By using the MSBOS to eliminate unnecessary blood orders, the authors calculated a potential reduction in hospital charges and actual costs of $211,448 and $43,135 per year, respectively, or $8.89 and $1.81 per surgical patient, respectively. An institution-specific MSBOS can be created, using blood utilization data extracted from an anesthesia information management system along with our proposed algorithm. Using these methods to optimize the process of preoperative blood ordering can potentially improve operating room efficiency, increase patient safety, and decrease costs.

  6. Application of numerical analysis methods to thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs

  7. Retrospective dosimetry of Chernobyl liquidators

    International Nuclear Information System (INIS)

    Chumak, V.V.; Bakhanova, E.V.; Sholom, S.V.; Pasalskaya, L.F.; Bouville, A.; Krjuchkov, V.P.

    2000-01-01

    sets and, clearly, may lead to conclusion regarding the adequacy of the data set in general, not on individual basis. Another possibility to verify existing dose records is application of reliable retrospective dosimetric techniques, which may be used as a reference. Dosimetric screening of the study cohort requires a tool, which should meet two basic requirements: to be cheap and practical, and to be applicable to all subjects (desirably even post mortem). Till recent time such tool was missing and none of the known methods of retrospective dosimetry matched these criteria. Therefore in the novel method of Soft Expert Assessment Dosimetry (SEAD) was developed by the International Dosimetric Group operating under auspices of Ukraine-USA-France and CEC-Russia-Byelarus collaboration. This method is based on the analysis of information acquired from interviewing of liquidators and exploits regularities of dose distributions. The main advantage of this method is applicability to all subjects making it good for the screening of the cohort. Case-control study requires closer consideration of fewer subjects and in this regard high precision techniques (like EPR) make use. High cost of analyses is acceptable in this case. Practical implementation of this approach is illustrated by some on-going studies. Pros and contras of selected methods, as well as implementation considerations will be discussed as well. (author)

  8. Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)

    International Nuclear Information System (INIS)

    Trotot, P.M.; Sansonetti, P.J.; Levillain, R.; Cabanis, E.A.; Lavayssiere, R.; Sandoz-Tronca, C.

    1988-01-01

    Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They certainly indicate early involvement of the CNS after primary infection by the HIV virus. They may either represent scars of the primary infection or early alterations announcing developing encephalopathy [fr

  9. Description of new systems for acquiring in situ data from deep wells

    International Nuclear Information System (INIS)

    Peyrus, J.C.; Vinson, J.M.

    1984-02-01

    The studies being made by CEA/IPSN in respect of storage sites in a granite medium require a knowledge of the physico-chemical parameters of the water in the geological formation, since these waters are the principal vectors of hydrogeological transfers. In order to attain this objective, the design, construction and operation of two new experimental systems for sampling water in a deep well without modifying the pressure of the fluid as well was undertaken, at the same time as the measurement of pH, oxidation-reduction potential and water temperature of the aqueous medium. A pressure-compensated combined pH-Eh electrode for completely representative measurements down to 2000 metres was studied. The first results obtained at the Auriat site in France show confrontation with water belonging to the sodium bicarbonate facies, which is rich in CO 2 , CH 4 and H 2 , and that pH and Eh vary as a function of the mineralogical nature of the granite and tectonic fractures

  10. TELDE thermoluminescent dosimetry system

    International Nuclear Information System (INIS)

    Shvarts, K.K.; Nemiro, E.A.; Bichev, V.R.; Gotlib, V.I.; Grant, Z.A.; Grube, M.M.; Gubatova, D.J.

    1981-01-01

    The TELDE dosimetric set designed for measurement of x- and γ- rays doses with energy more than 10 keV is described. The set consists of thermoluminescent detectors from LiF (Ca, Mg, Ti). The detectors are polycrystalline pellets with diameter 3.5+-0.3 mm and thickness 2+-0.2 mm. In the thermoluminescence detectors both the peak and integral measurement methods are realized. Apart from this the TELDE set comprises the electron unit for the pre-irradiation thermal treatment of detectors, special bones for detectors storage and transportation, devices for their package in polyethelene film and containers to wear the detectors. The TELDE set allows to perform measurements on people or animals in radiobiological experiments as well as in water, solid or porous phantoms [ru

  11. The Mayak Worker Dosimetry System (MWDS-2013): a comparison of intakes based on urine versus autopsy data from Mayak workers using the Leggett systemic model for plutonium

    International Nuclear Information System (INIS)

    Birchall, A.; Dorrian, M.-D.; Suslova, K. G.; Sokolova, A. B.

    2017-01-01

    The Mayak Worker Dosimetry System-2013 (MWDS-2013) uses a model developed by Leggett and colleagues to represent the biokinetic behaviour of plutonium after uptake to blood. Of particular importance, with regard to estimating intakes (and doses), is the distribution of activity between urine and body organs (particularly liver and skeleton). In this study, measurement data (urine and autopsy) from around 500 Mayak workers have been used to validate use of this model. A robust method has been developed and used to estimate intakes from both urine and autopsy data separately, and the ratio of these estimates has been calculated for each worker. The geometric mean ratio has been shown to lie within a range of 0.92-1.14, depending on assumptions made. Since this range includes 1, the hypothesis that the model is unbiased with regard to estimating intakes either with urine or autopsy data cannot be rejected on the basis of these data. This lends weight to the argument for increasing the MWDS-2013 cohort to include an additional 500 workers for whom only autopsy data are available, and who have previously been excluded from the cohort. Future directions in which this work could be extended are also suggested. (authors)

  12. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  13. Relative dosimetry by Ebt-3

    International Nuclear Information System (INIS)

    De Leon A, M. A.; Rivera M, T.; Hernandez O, J. O.

    2015-10-01

    In the present work relative dosimetry in two linear accelerator for radiation therapy was studied. Both Varian Oncology systems named Varian Clinac 2100-Cd and MLC Varian Clinac i X were used. Gaf Chromic Ebt-3 film was used. Measurements have been performed in a water equivalent phantom, using 6 MV and 18 MV photon beams on both Linacs. Both calibration and Electron irradiations were carried out with the ionization chamber placed at the isocenter, below a stack of solid water slabs, at the depth of dose maximum (D max), with a Source-to-Surface Distance (SSD) of 100 cm and a field size of 10 cm x 10 cm. Calibration and dosimetric measurements photons were carried out under IAEA-TRS 398 protocol. Results of relative dosimetry in the present work are discussed. (Author)

  14. Project 252Cf-D2O. The multisphere system of neutron dosimetry and spectrometry (M.S.-N.D.S.). Studies of applications to health physics

    International Nuclear Information System (INIS)

    Zaborowski, H.L.

    1976-10-01

    The project 252 Cf-D 2 O is articulated upon the utilization of a 200μg nominal 252 Cf spontaneous neutron fission source, used bare and under D 2 O spherical moderators, giving leakage neutron spectra experimentally known and/or calculated. This project has for objective the applications of those sources to Health Physics, in dosimetry (calibration of ''rad'' and ''rem-meters'') and in spectrometry, associated with the experimental system of measurements made by the generalization of the BONNER Spheres, known as ''the Multisphere System''. This communication describes the normalization method used and the results obtained leading to the adoption of a reference matrix called ''the Log-Normal Multisphere Matrix'' (LN-MM) giving the energies response functions of the generalized system for all the spheres diameters between 40 and 400 millimeters and for all the energies between 0.4eV and 15MeV [fr

  15. Characterization of the materials used in the construction of a physical phantom for calibration of {sup 18}F-FDG internal dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Vital, Katia D.; Mendes, Bruno M.; Fonseca, Telma C.F.; Silva, Teógenes A. da, E-mail: katiadvitall@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte - MG (Brazil)

    2017-07-01

    The Internal Dosimetry Laboratory (LDI) of the Nuclear Technology Development Center (CDTN) in Minas Gerais, Brazil, is responsible for the routine monitoring of Occupationally Exposed Individuals (OEIs) to {sup 18}F-FDG and other radiopharmaceuticals produced at CDTN. The monitoring system is usually calibrated using a physical head simulator, since {sup 18}F is usually incorporated into the brain at the time of contamination. However, the geometry of the brain is not adequately represented by the latex pocket, which does not fill the entire volume of the volume skull. In this study, the characterization of the materials regarding the composition, density and attenuation coefficient of the materials used in the production of the new physical head simulator was carried out. An equivalent tissue material containing 97% water, 2.5% agar, 0.5% urea and 8 MBq of {sup 18}F-FDG was produced, the interior of the skull was filled with the material. After solidification, experimental measurements were performed on the NaI(Tl) 3 {sup x}3{sup s}cintillation detector, the density of the simulant material was determined by the flotation method and the attenuation coefficient of the XCOM database software provided by NIST. It was concluded that the PVC skull has acceptable characteristics to simulate a human skull in {sup 18}F-FDG internal dosimetry. The agar gel was shown to be a stable material capable of modeling different geometries and simulating the incorporation of {sup 18}F-FDG into the brain. (author)

  16. Characterization of the materials used in the construction of a physical phantom for calibration of 18F-FDG internal dosimetry system

    International Nuclear Information System (INIS)

    Vital, Katia D.; Mendes, Bruno M.; Fonseca, Telma C.F.; Silva, Teógenes A. da

    2017-01-01

    The Internal Dosimetry Laboratory (LDI) of the Nuclear Technology Development Center (CDTN) in Minas Gerais, Brazil, is responsible for the routine monitoring of Occupationally Exposed Individuals (OEIs) to 18 F-FDG and other radiopharmaceuticals produced at CDTN. The monitoring system is usually calibrated using a physical head simulator, since 18 F is usually incorporated into the brain at the time of contamination. However, the geometry of the brain is not adequately represented by the latex pocket, which does not fill the entire volume of the volume skull. In this study, the characterization of the materials regarding the composition, density and attenuation coefficient of the materials used in the production of the new physical head simulator was carried out. An equivalent tissue material containing 97% water, 2.5% agar, 0.5% urea and 8 MBq of 18 F-FDG was produced, the interior of the skull was filled with the material. After solidification, experimental measurements were performed on the NaI(Tl) 3 x 3 s cintillation detector, the density of the simulant material was determined by the flotation method and the attenuation coefficient of the XCOM database software provided by NIST. It was concluded that the PVC skull has acceptable characteristics to simulate a human skull in 18 F-FDG internal dosimetry. The agar gel was shown to be a stable material capable of modeling different geometries and simulating the incorporation of 18 F-FDG into the brain. (author)

  17. Application of gel dosimetry - A preliminary study on verification of uniformity of activity and length of source used in Beta-Cath system

    International Nuclear Information System (INIS)

    Subramaniam, S.; Rabi Raja Singh, I.; Visalatchi, S.; Paul Ravindran, B.

    2002-01-01

    Recently the intraluminal irradiation of coronary arteries following balloon angioplasty is found to reduce proliferation of smooth muscle cells and restenosis. Among the isotopes used for the intracoronary irradiation, 90 Sr/Y appears to be ideal (H I Almos et al, 1996). In 1984 Gore et al proposed that radiation induced changes in the well-established Fricke solution could be probed with Nuclear Magnetic Resonance (NMR) relaxation measurements rather than using conventional spectrophotometry measurements. This was a major step in the development of gel dosimetry and since then gel dosimetry has been one of the major advances in the dosimetry of complex radiation fields has been in the area of gel dosimetry. In this preliminary work on gel dosimetry we present the verification of uniformity of activity along the length of the source train and verification of the length of the source used in the Beta-Cath system used for intracoronary brachytherapy with ferrous gel dosimeter. The Beta-Cath system obtained from Novoste, Norcross, GA was used in this study. It consists of a source train of 16 90 Sr/Y sources each of length 2.5mm. The total length of the source train is 40mm. For preparation of the Ferrous-Gelatin Gel, the recipe provided by the London Regional Cancer Center, London Ontario, Canada was used. Stock solutions of 50mM H 2 SO 4 , 0.3 mM ferrous ammonium sulphate, 0.05mM Xylenol orange was first prepared. The gel was prepared by mixing 4% gelatin with distilled water while stirring in a water bath at 40-42 deg. C. Acid solution, Ferrous ammonium sulphate solution and Xylenol orange were added and stirred in the water bath for about an hour to allow aeration. The mixture was poured in to three 20ml syringes to form the gel and stored in the refrigerator at 5 deg. C. For irradiation with Beta-Cath, the gel was prepared in three cylindrical 20ml syringes. A nylon tube having the same dimension as that of the delivery catheter used in intra-coronary was placed

  18. Individual monitoring dosimetry in Europe

    International Nuclear Information System (INIS)

    Menzel, H.G.

    1991-01-01

    This report discusses the various types of individual monitoring systems presently in use within the European community and neutron dosimetry research being coordinated by the EURADOS working group. Research is currently being conducted on nuclear track dosimeters, primarily with CR-39 (TM), and TLD-albedo dosimeters. Studies are being conducted on the energy and angular response of each type of dosimeter. Because the response of dosimeters depends on the energy of the neutrons, it is necessary to have spectral information to accurately assess the dose. Neutron energy spectrum measurements are being performed in typical work place environments. Work is also progressing on development of calibration sources which will be representative of the neutron energy spectrum found in typical neutron exposure situations. This work utilizes 14 MeV neutrons incident on a uranium block with various other filters. Research is also continuing on neutron dosimetry using tissue equivalent proportional counters and microdosimetric techniques. The results of intercomparisons between several different instruments are discussed. In addition to personnel dosimetry, these systems are being used to record the dose to passengers and flight crews aboard commercial aircraft

  19. Pipecolic Acid Orchestrates Plant Systemic Acquired Resistance and Defense Priming via Salicylic Acid-Dependent and -Independent Pathways.

    Science.gov (United States)

    Bernsdorff, Friederike; Döring, Anne-Christin; Gruner, Katrin; Schuck, Stefan; Bräutigam, Andrea; Zeier, Jürgen

    2016-01-01

    We investigated the relationships of the two immune-regulatory plant metabolites, salicylic acid (SA) and pipecolic acid (Pip), in the establishment of plant systemic acquired resistance (SAR), SAR-associated defense priming, and basal immunity. Using SA-deficient sid2, Pip-deficient ald1, and sid2 ald1 plants deficient in both SA and Pip, we show that SA and Pip act both independently from each other and synergistically in Arabidopsis thaliana basal immunity to Pseudomonas syringae. Transcriptome analyses reveal that SAR establishment in Arabidopsis is characterized by a strong transcriptional response systemically induced in the foliage that prepares plants for future pathogen attack by preactivating multiple stages of defense signaling and that SA accumulation upon SAR activation leads to the downregulation of photosynthesis and attenuated jasmonate responses systemically within the plant. Whereas systemic Pip elevations are indispensable for SAR and necessary for virtually the whole transcriptional SAR response, a moderate but significant SA-independent component of SAR activation and SAR gene expression is revealed. During SAR, Pip orchestrates SA-dependent and SA-independent priming of pathogen responses in a FLAVIN-DEPENDENT-MONOOXYGENASE1 (FMO1)-dependent manner. We conclude that a Pip/FMO1 signaling module acts as an indispensable switch for the activation of SAR and associated defense priming events and that SA amplifies Pip-triggered responses to different degrees in the distal tissue of SAR-activated plants. © 2016 American Society of Plant Biologists. All rights reserved.

  20. SU-C-201-02: Dosimetric Verification of SBRT with FFF-VMAT Using a 3-D Radiochromic/Optical-CT Dosimetry System

    Energy Technology Data Exchange (ETDEWEB)

    Na, Y; Black, P; Wuu, C [Columbia University, New York, NY (United States); Adamovics, J [Department of Chemistry and Biology, Rider University, Skillman, NJ (United States)

    2016-06-15

    Purpose: With an increasing use of small field size and high dose rate irradiation in the advances of radiotherapy techniques, such as stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS), an in-depth quality assurance (QA) system is required. The purpose of this study is to investigate a high resolution optical CT-based 3D radiochromic dosimetry system for SBRT with intensity modulated radiotherapy (IMRT) and flattening filter free (FFF) volumetric modulated arc therapy (VMAT). Methods: Cylindrical PRESAGE radiochromic dosimeters of 10cm height and 11cm diameter were used to validate SBRT. Four external landmarks were placed on the surface of each dosimeter to define the isocenter of target. SBRT plans were delivered using a Varian TrueBeam™ linear accelerator (LINAC). Three validation plans, SBRT with IMRT (6MV 600MU/min), FFF-VMAT (10MV 2400MU/min), and mixed FFF-VMAT (6MV 1400MU/min, 10MV 2400MU/min), were delivered to the PRESAGE dosimeters. Each irradiated PRESAGE dosimeter was scanned using a single laser beam optical CT scanner and reconstructed with a 1mm × 1mm high spatial resolution. The comparison of measured dose distributions of irradiated PRESAGE dosimeters to those calculated by Pinnacle{sup 3} treatment planning system (TPS) were performed with a 10% dose threshold, 3% dose difference (DD), and 3mm distance-to-agreement (DTA) Gamma criteria. Results: The average pass rates for the gamma comparisons between PRESAGE and Pinnacle{sup 3} in the transverse, sagittal, coronal planes were 94.6%, 95.9%, and 96.4% for SBRT with IMRT, FFF-VMAT, and mixed FFF-VMAT plans, respectively. A good agreement of the isodose distributions of those comparisons were shown at the isodose lines 50%, 70%, 80%, 90% and 98%. Conclusion: This study demonstrates the feasibility of the high resolution optical CT-based 3D radiochromic dosimetry system for validation of SBRT with IMRT and FFF-VMAT. This dosimetry system offers higher precision QA with 3D

  1. Theoretical basis for dosimetry

    International Nuclear Information System (INIS)

    Carlsson, G.A.

    1985-01-01

    Radiation dosimetry is fundamental to all fields of science dealing with radiation effects and is concerned with problems which are often intricate as hinted above. A firm scientific basis is needed to face increasing demands on accurate dosimetry. This chapter is an attempt to review and to elucidate the elements for such a basis. Quantities suitable for radiation dosimetry have been defined in the unique work to coordinate radiation terminology and usage by the International Commission on Radiation Units and Measurements, ICRU. Basic definitions and terminology used in this chapter conform with the recent ''Radiation Quantities and Units, Report 33'' of the ICRU

  2. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both by international organizations (IAEA) and national laboratories have helped to improve the reliability of dose measurements. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading to traceable and reliable dosimetry are discussed. (author)

  3. Dosimetry. Standard practice for dosimetry in gamma irradiation facilities for food and non-food processing

    International Nuclear Information System (INIS)

    2008-01-01

    This Ghana Standard outlines the installation qualification program for an irradiator and the dosimetry procedures to be followed during operational qualification, performance qualification and routine processing in facilities that process food and non-food with gamma rays. This is to ensure that the product has been treated with predetermined range of absorbed dose. It is not intended for use in X-ray and electron beam facilities and therefore dosimetry systems in such facilities are not covered

  4. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  5. Quality control through dosimetry at a contract radiation processing facility

    International Nuclear Information System (INIS)

    Du Plessis, T.A.; Roediger, A.H.A.

    1985-01-01

    Reliable dosimetry procedures constitute a very important part of process control and quality assurance at a contract gamma radiation processing facility that caters for a large variety of different radiation applications. The choice, calibration and routine intercalibration of the dosimetry systems employed form the basis of a sound dosimetry policy in radiation processing. With the dosimetric procedures established, detailed dosimetric mapping of the irradiator upon commissioning (and whenever source modifications take place) is carried out to determine the radiation processing characteristics and peformance of the plant. Having established the irradiator parameters, routine dosimetry procedures, being part of the overall quality control measures, are employed. In addition to routine dosimetry, independent monitoring of routine dosimetry is performed on a bi-monthly basis and the results indicate a variation of better than 3%. On an annaul basis the dosimetry systems are intercalibrated through at least one primary standard dosimetry laboratory and to date a variation of better than 5% has been experienced. The company also participates in the Pilot Dose Assurance Service of the International Atomic Energy Agency, using the alanine/ESR dosimetry system. Routine calibration of the instrumentation employed is carried out on a regular basis. Detailed permanent records are compiled on all dosimetric and instrumentation calibrations, and the routine dosimetry employed at the plant. Certificates indicating the measured absorbed radiation doses are issued on request and in many cases are used for the dosimetric release of sterilized medical and pharmaceutical products. These procedures, used by Iso-Ster at its industrial gamma radiation facility, as well as the experience built up over a number of years using radiation dosimetry for process control and quality assurance are discussed. (author)

  6. 10 CFR 835.1304 - Nuclear accident dosimetry.

    Science.gov (United States)

    2010-01-01

    ...) Methods and equipment for analysis of biological materials; (3) A system of fixed nuclear accident... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... 10 Energy 4 2010-01-01 2010-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304...

  7. Dosimetry computer module of the gamma irradiator of ININ

    International Nuclear Information System (INIS)

    Ledezma F, L. E.; Baldomero J, R.; Agis E, K. A.

    2012-10-01

    This work present the technical specifications for the upgrade of the dosimetry module of the computer system of the gamma irradiator of the Instituto Nacional de Investigaciones Nucleares (ININ) whose result allows the integration and consultation of information in industrial dosimetry subject under an outline client-server. (Author)

  8. Radiation chemical dosimetry by means of nitrate-nitrite

    International Nuclear Information System (INIS)

    Tormo Ferrero, M.J.

    1977-01-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolisis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (author) [es

  9. Present status and expected progress in radiation processing dosimetry

    DEFF Research Database (Denmark)

    Kovács, A.; Miller, A.

    2004-01-01

    The paper describes the present status of radiation processing dosimetry including the methods used most widely in gamma- and electron processing as well as the new methods under development or introduction. The recent trends with respect to calibrationof routine dosimetry systems as well...

  10. Radiation chemical dosimetry by means of nitrate-nitrite

    International Nuclear Information System (INIS)

    Tormo Ferrero, M. J.

    1977-01-01

    The different chemical systems used in dosimetry and the selection criteria for them are described. The general topics in dosimetry with alkali nitrates as well as the phenomena occurring in their radiolysis are also treated. The possibility of application in dosimetric areas useful in radiosterilization and industrial processes is studied too. (Author) 22 refs

  11. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  12. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  13. Czech results at criticality dosimetry intercomparison 2002.

    Science.gov (United States)

    Frantisek, Spurný; Jaroslav, Trousil

    2004-01-01

    Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.

  14. JENDL Dosimetry File

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  15. JENDL Dosimetry File

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  16. Individual dosimetry of workers and patients: implementation and perspectives; La dosimetrie individuelle des travailleurs et de patients: mise en oeuvre et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E

    2008-07-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  17. SU-F-SPS-06: Implementation of a Back-Projection Algorithm for 2D in Vivo Dosimetry with An EPID System

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Reyes, B; Rodriguez Perez, E; Sosa Aquino, M [Universidad de Guanajuato, Leon, Guanajuato (Mexico)

    2016-06-15

    Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results: A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.

  18. Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems.

    Science.gov (United States)

    Jentzen, Walter; Weise, Reiner; Kupferschläger, Jürgen; Freudenberg, Lutz; Brandau, Wolfgang; Bares, Ronald; Burchert, Wolfgang; Bockisch, Andreas

    2008-03-01

    This study evaluated the absolute quantification of iodine-124 ((124)I) activity concentration with respect to the use of this isotope for dosimetry before therapies with (131)I or (131)I-labeled radiotherapeuticals. The recovery coefficients of positron emission tomography(/computed tomography) PET(/CT) systems using (124)I were determined using phantoms and then validated under typical conditions observed in differentiated thyroid cancer (DTC) patients. Transversal spatial resolution and recovery measurements with (124)I and with fluorine-18 ((18)F) as the reference were performed using isotope-containing line sources embedded in water and six isotope-containing spheres 9.7 to 37.0 mm in diameter placed in water-containing body and cylinder phantoms. The cylinder phantom spheres were filled with (18)F only. Measurements in two-dimensional (2D) and three-dimensional (3D) modes were performed using both stand-alone PET (EXACT HR(+)) and combined PET/CT (BIOGRAPH EMOTION DUO) systems. Recovery comparison measurements were additionally performed on a GE ADVANCE PET system using the cylinder phantom. The recovery coefficients were directly determined using the activity concentration of circular regions of interest divided by the prepared activity concentration determined by the dose calibrator. The recovery correction method was validated using three consecutive scans of the body phantom under our (124)I PET(/CT) protocol for DTC patients. Compared with that of (18)F, transversal spatial resolution of (124)I was slightly, but statistically significantly degraded (7.4 mm vs. 8.3 mm, P or =12.6 mm in diameter. Recovery correction is mandatory for (124)I PET quantification, even for large structures. To ensure accurate dosimetry, thorough absolute recovery measurements must be individually established for the particular PET scanner and radionuclide to be used.

  19. Quality system applied to the development and operation of the environmental and internal dosimetry laboratory of the National Atomic Energy Commission

    International Nuclear Information System (INIS)

    Tossi, Mirta H.; Picardi, Haydee M.; Rona, Nicolas F.; Gonzalez, Maria I.; Cohen, Isaac M.

    1997-01-01

    The characteristics of the quality plan , applied to the project of construction, commissioning and operation of the Laboratory of Internal and Environmental Dosimetry of Comision Nacional de Energia Atomica, are described. The basic objectives are: to carry out the determination of plutonium, natural and enriched uranium in biological samples, involving the operation of five plants connected with the fuel cycles, and radionuclides in environmental samples; to achieve enough sensitivity in the methods, so as to detect trends which could require the application of corrective measures or, alternatively, the practices standardisation that contribute to an operation improvement; to adequate the laboratory, under full operation conditions, for inclusion in a dose evaluation and environmental monitoring integrated system. (author). 1 ref

  20. Radiotherapy gel dosimetry

    International Nuclear Information System (INIS)

    Baldock, C.

    2002-01-01

    shapes and sizes while sparing normal tissue. The situation is further complicated if the normal tissues are critical organs or are particularly sensitive to radiation. Radiotherapy techniques employed to obtain a closer conformation of the dose distribution to the tumour volume are referred to as conformal radiotherapy techniques. The clinical implementation of conformal therapy has been delayed by limitations in the verification of conformal dose distributions calculated by treatment planning systems prior to the irradiation of the patient and the verification of complex treatments during its delivery to the patient. There are several aspects of conformal therapy that complicate dose verification. To achieve the dose distributions conforming to complex 3D volumes, high dose gradients arise in the treatment volume. Further, overdose or underdose regions can exist when separate radiation fields are used to deliver additional radiation. These aspects require that practical dose measurement (dosimetry) techniques be able to integrate dose over time and easily measure dose distributions in 3D with high spatial resolution. Traditional dosimeters, such as ion chambers, thermoluminescent dosimeters and radiographic film do not fulfil these requirements. Novel gel dosimetry techniques are being developed in which dose distributions can potentially be determined in vitro in 3D using anthropomorphic phantoms to simulate a clinically irradiated situation. As long ago as the 1950's, radiation-induced colour change in dyes was used to investigate radiation doses in gels. It was subsequently shown that radiation induced changes in nuclear magnetic resonance (NMR) relaxation properties of gels infused with conventional Fricke dosimetry solutions could be measured using magnetic resonance imaging (MRI). In Fricke gels, Fe 2+ ions in ferrous sulphate solutions are usually dispersed throughout a gelatin, agarose or PVA matrix. Radiation-induced changes in the dosimeters are considered to

  1. TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Miles, D; Yoon, S [Duke University Medical Physics Graduate Program, Durham, NC (United States); Adamovics, J [Department of Chemistry and Biology, Rider University, Skillman, NJ (United States); Oldham, M [Duke University Medical Center, Durham, NC (United States)

    2016-06-15

    Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

  2. TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

    International Nuclear Information System (INIS)

    Miles, D; Yoon, S; Adamovics, J; Oldham, M

    2016-01-01

    Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

  3. Determination of the components of uncertainty for a dosimetry system in radiation protection; Determinacion de las componentes de incertidumbre para un sistema de dosimetria en radio proteccion

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, F., E-mail: flopez@unan.edu.ni [Universidad Nacional Autonoma de Nicaragua, Managua (Nicaragua); Cabral, T.S.; Peixoto, J.G. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    This work is about the theoretical calculation of uncertainties associated to the dosimetry of photons of a {sup 137}Cs source that will be used in a Dosimetry Laboratory. In this case recognition of the influence quantities that provide most uncertainty and the right choice of resolution of auxiliary equipment to obtain the smallest uncertainties according to the laboratory. (author)

  4. Survey of international personnel radiation dosimetry programs

    International Nuclear Information System (INIS)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  5. Applicability of thermoluminescent dosimeters in X-ray organ dose determination and in the dosimetry of systemic and boron neutron capture radiotherapy

    International Nuclear Information System (INIS)

    Aschan, C.

    1999-01-01

    The main detectors used for clinical dosimetry are ionisation chambers and semiconductors. Thermoluminescent (TL) dosimeters are also of interest because of their following advantages: (i) wide useful dose range, (ii) small physical size, (iii) no need for high voltage or cables, i.e. stand alone character, and (iv) tissue equivalence (LiF) for most radiation types. TL detectors can particularly be used for the absorbed dose measurements performed with the aim to investigate cases where dose prediction is difficult and not as part of a routine verification procedure. In this thesis, the applicability of TL detectors was studied in different clinical applications. Particularly, the major phenomena (e.g. energy dependence, sensitivity to high LET radiation, reproducibility) affecting on the precision and accuracy of TL detectors in the dose estimations were considered in this work. In organ dose determinations of diagnostic X-ray examinations, the TL detectors were found to be accurate within 5% (1 S.D.). For in viva studies using internal irradiation source, i.e. for systemic radiation therapy, a method for determining the absorbed doses to organs was introduced. The TL method developed was found to be able to estimate the absorbed doses to those critical organs near the body surface within 50%. In the mixed neutron-gamma field of boron neutron capture therapy (BNCT), TL detectors were used for gamma dose and neutron fluence measurements. They were found able to measure the neutron dose component with the accuracy of 16%, and therefore to be a useful addition to the activation foils in BNCT neutron dosimetry. The absorbed gamma doses can be measured with TL detectors within 20% in the mixed neutron-gamma field, which enables in viva measurements at BNCT beams with approximately the same accuracy. In this study, the uncertainties of TL dosimeters were found to be high but not essentially greater than those in other measurement techniques used for clinical dosimetry

  6. MR findings of central nervous system involvement in acquired immunodeficiency syndrome patient : a report of two cases

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Dong Ik; Lee, Byeong Hee; Jeong, Sun Yang

    1996-01-01

    Central nervous system (CNS) manifestations in acquired immunodeficiency syndrome (AIDS) patients are an early and common feature. The spectrum of AIDS-related CNS diseases are encephalitis caused by the human immunodeficiency virus(HIV) itself, opportunistic infection, infarct and malignancy. We experienced two cases of CNS involvement in AIDS and they were serologically diagnosed as HIV encephalitis and CNS toxoplasmosis, respectively. In the case of the HIV encephalitis patient, brain MRI showed a non-enhancing lesion with high signal intensity on T2WI and low signal on T1WI and there was no mass effect on the right frontal lobe, periventricular white matter, splenium of the corpus callosum or bilateral basal ganglia. In the other case of CNS toxoplasmosis, MR showed multiple nodular and rim enhanced mass lesions in the right basal ganglia, thalamus and periventricular white matter, which were of low signal intensity on T1WI and of high intensity on T2WI. We thus report the related MRI findings

  7. SU-C-BRD-06: Sensitivity Study of An Automated System to Acquire and Analyze EPID Exit Dose Images

    Energy Technology Data Exchange (ETDEWEB)

    Olch, A; Zhuang, A [University of Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: The dosimetric consequences of errors in patient setup or beam delivery and anatomical changes are not readily known. A new product, PerFRACTION (Sun Nuclear Corporation), is designed to detect these errors by comparing the EPID exit dose image from each field of each fraction to those from baseline fraction images. This work investigates the sensitivity of PerFRACTION to detect the deviation of induced errors in a variety of realistic scenarios. Methods: Eight plans were created mimicking potential delivery or setup errors. The plans consisted of a nominal field and the field with an induced error. These were used to irradiate the EPID simulating multiple fractions with and without the error. Integrated EPID images were acquired in clinical mode and saved in ARIA. PerFRACTION automatically pulls the images into its database and performs the user defined comparison. In some cases, images were manually pushed to PerFRACTION. We varied the distance-to-agreement or dose tolerance until PerFRACTION showed failing pixels in the affected region and recorded the values. We induced errors of 1mm and greater in jaw, MLC, and couch position, 2 degree collimation rotation (patient yaw), and 0.5% to 1.5% in machine output. Both static and arc fields with the rails in or out were also acquired and compared. Results: PerFRACTION detected position errors of the jaws, MLC, and couch with an accuracy of better than 0.5 mm, and 0.2 degrees for collimator and gantry error. PerFRACTION detected a machine output error within 0.2% and detected the change in rail position. Conclusion: A new automated system for monitoring daily treatments for machine or patient variations from the first fraction using integrated EPID images was found to be sensitive enough to detect small positional, angular, and dosimetric errors within 0.5mm, 0.2 degrees, and 0.2%, respectively. Sun Nuclear Corporation has provided a software license for the product described.

  8. Use of the GATE Monte Carlo package for dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Visvikis, D. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France)]. E-mail: Visvikis.Dimitris@univ-brest.fr; Bardies, M. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Chiavassa, S. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Danford, C. [Department of Medical Physics, MSKCC, New York (United States); Kirov, A. [Department of Medical Physics, MSKCC, New York (United States); Lamare, F. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France); Maigne, L. [Departement de Curietherapie-Radiotherapie, Centre Jean Perrin, F 63000 Clemont-Ferrand (France); Staelens, S. [UGent-ELIS, St-Pietersnieuwstraat, 41, B 9000 Gent (Belgium); Taschereau, R. [CRUMP Institute for Molecular Imaging, UCLA, Los Angeles (United States)

    2006-12-20

    One of the roles for Monte Carlo (MC) simulation studies is in the area of dosimetry. A number of different codes dedicated to dosimetry applications are available and widely used today, such as MCNP, EGSnrc and PTRAN. However, such codes do not easily facilitate the description of complicated 3D sources or emission tomography systems and associated data flow, which may be useful in different dosimetry application domains. Such problems can be overcome by the use of specific MC codes such as GATE (GEANT4 Application to Tomographic Emission), which is based on Geant4 libraries, providing a scripting interface with a number of advantages for the simulation of SPECT and PET systems. Despite this potential, its major disadvantage is in terms of efficiency involving long execution times for applications such as dosimetry. The strong points and disadvantages of GATE in comparison to other dosimetry specific codes are discussed and illustrated in terms of accuracy, efficiency and flexibility. A number of features, such as the use of voxelised and moving sources, as well as developments such as advanced visualization tools and the development of dose estimation maps allowing GATE to be used for dosimetry applications are presented. In addition, different examples from dosimetry applications with GATE are given. Finally, future directions with respect to the use of GATE for dosimetry applications are outlined.

  9. INTERCOMPARISON ON THE MEASUREMENT OF THE QUANTITY PERSONAL DOSE EQUIVALENT HP(10) IN PHOTON FIELDS. LINEARITY DEPENDENCE, LOWER LIMIT OF DETECTION AND UNCERTAINTY IN MEASUREMENT OF DOSIMETRY SYSTEMS OF INDIVIDUAL MONITORING SERVICES IN GABON AND GHANA.

    Science.gov (United States)

    Ondo Meye, P; Schandorf, C; Amoako, J K; Manteaw, P O; Amoatey, E A; Adjei, D N

    2017-12-01

    An inter-comparison study was conducted to assess the capability of dosimetry systems of individual monitoring services (IMSs) in Gabon and Ghana to measure personal dose equivalent Hp(10) in photon fields. The performance indicators assessed were the lower limit of detection, linearity and uncertainty in measurement. Monthly and quarterly recording levels were proposed with corresponding values of 0.08 and 0.025 mSv, and 0.05 and 0.15 mSv for the TLD and OSL systems, respectively. The linearity dependence of the dosimetry systems was performed following the requirement given in the Standard IEC 62387 of the International Electrotechnical Commission (IEC). The results obtained for the two systems were satisfactory. The procedure followed for the uncertainty assessment is the one given in the IEC technical report TR62461. The maximum relative overall uncertainties, in absolute value, expressed in terms of Hp(10), for the TL dosimetry system Harshaw 6600, are 44. 35% for true doses below 0.40 mSv and 36.33% for true doses ≥0.40 mSv. For the OSL dosimetry system microStar, the maximum relative overall uncertainties, in absolute value, are 52.17% for true doses below 0.40 mSv and 37.43% for true doses ≥0.40 mSv. These results are in good agreement with the requirements for accuracy of the International Commission on Radiological protection. When expressing the uncertainties in terms of response, comparison with the IAEA requirements for overall accuracy showed that the uncertainty results were also acceptable. The values of Hp(10) directly measured by the two dosimetry systems showed a significant underestimation for the Harshaw 6600 system, and a slight overestimation for the microStar system. After correction for linearity of the measured doses, the two dosimetry systems gave better and comparable results. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1982-01-01

    The measurement of neutron exposures to personnel is an issue that has received increased attention in the last few years. It is important to consider key aspects of the whole dosimetry system when developing dose estimates. This begins with selection of proper dosimeters and survey instruments, and extends through the calibration methods. One must match the spectral response and sensitivity of the dosimeter to the spectral characteristics of the neutron fields. Threshold detectors that are insensitive to large fractions of neutrons in the lower energy portion of reactor spectra should be avoided. Use of two or more detectors with responses that complement each other will improve measurement quality. It is important to understand the spectral response of survey instruments, so that spectra which result in significant overresponse do not lead to overestimation of dose. Calibration sources that do not match operational field spectra can contribute to highly erroneous results. In those situations, in-field calibration techniques should be employed. Although some detection developments have been made in recent years, a lot can be done with existing technology until fully satisfactory, long term solutions are obtained

  11. Characterization of a fiber-taper charge-coupled device system for plastic scintillation dosimetry and comparison with the traditional lens system

    International Nuclear Information System (INIS)

    Gagnon, Louis-Philippe; Beddar, Sam; Beaulieu, Luc

    2015-01-01

    the FTS could measure doses more accurately than the LS and that low-dose measurements were feasible without the complexity of a lens-based system. The FTS would therefore be better adapted for routine clinical usage of fiber arrays. The increased SNR in the FTS suggests that water-equivalent PSDs with smaller radii could be used to obtain measurements with greater spatial resolution, further simplifying the use of PSDs for “in-vivo” monitoring and small-field dosimetry. - Highlights: • We compare a fiber-taper-based photon-counting system to a lens based system. • We quantify the increase of photons collected on the CCD using fiber guiding. • We study the systems SNR and accuracy increase offered by the taper system. • Increased accuracy at low-dose measurements is achieved with the use of the taper

  12. NMR mechanisms in gel dosimetry

    International Nuclear Information System (INIS)

    Schreiner, L J

    2009-01-01

    Nuclear magnetic resonance was critical to the development of gel dosimetry, as it established the potential for three dimensional dosimetry with chemical dosimeter systems through magnetic resonance imaging [1]. In the last two decades MRI has served as the gold standard for imaging, while NMR relaxometry has played an important role in the development and understanding of the behaviour of new gel dosimetry systems. Therefore, an appreciation of the relaxation mechanisms determining the NMR behaviour of irradiated gel dosimeters is important for a full comprehension of a considerable component of the literature on gel dosimetry. A number of excellent papers have presented this important theory, this brief review will highlight some of the salient points made previously [1-5]. The spin relaxation of gel dosimeters (which determines the dose dependence in most conventional MR imaging) is determined principally by the protons on water molecules in the system. These water protons exist in different environments, or groups (see Figure 1): on bulk water, on water hydrating the chemical species that are being modified under irradiation, and on water hydrating the gel matrix used to spatially stabilize the dosimeter (e.g., gelatin, agarose, etc). The spin relaxation depends on the inherent relaxation rate of each spin group, that is, on the relaxation rate which would be observed for the specific group if it were isolated. Also, the different water environments are not isolated from each other, and the observed relaxation rate also depends on the rate of exchange of magnetization between the groups, and on the fraction of protons in each group. In fact, the water exchanges quickly between the environments, so that relaxation is in what is usually termed the fast exchange regime. In the limit of fast exchange, the relaxation of the water protons is well characterized by a single exponential and hence by a single apparent relaxation rate. In irradiated gel dosimeters this

  13. A genomic approach to identify regulatory nodes in the transcriptional network of systemic acquired resistance in plants.

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2006-11-01

    Full Text Available Many biological processes are controlled by intricate networks of transcriptional regulators. With the development of microarray technology, transcriptional changes can be examined at the whole-genome level. However, such analysis often lacks information on the hierarchical relationship between components of a given system. Systemic acquired resistance (SAR is an inducible plant defense response involving a cascade of transcriptional events induced by salicylic acid through the transcription cofactor NPR1. To identify additional regulatory nodes in the SAR network, we performed microarray analysis on Arabidopsis plants expressing the NPR1-GR (glucocorticoid receptor fusion protein. Since nuclear translocation of NPR1-GR requires dexamethasone, we were able to control NPR1-dependent transcription and identify direct transcriptional targets of NPR1. We show that NPR1 directly upregulates the expression of eight WRKY transcription factor genes. This large family of 74 transcription factors has been implicated in various defense responses, but no specific WRKY factor has been placed in the SAR network. Identification of NPR1-regulated WRKY factors allowed us to perform in-depth genetic analysis on a small number of WRKY factors and test well-defined phenotypes of single and double mutants associated with NPR1. Among these WRKY factors we found both positive and negative regulators of SAR. This genomics-directed approach unambiguously positioned five WRKY factors in the complex transcriptional regulatory network of SAR. Our work not only discovered new transcription regulatory components in the signaling network of SAR but also demonstrated that functional studies of large gene families have to take into consideration sequence similarity as well as the expression patterns of the candidates.

  14. Renal Shielding and Dosimetry for Patients With Severe Systemic Sclerosis Receiving Immunoablation With Total Body Irradiation in the Scleroderma: Cyclophosphamide or Transplantation Trial

    International Nuclear Information System (INIS)

    Craciunescu, Oana I.; Steffey, Beverly A.; Kelsey, Chris R.; Larrier, Nicole A.; Paarz-Largay, Cathy J.; Prosnitz, Robert G.; Chao, Nelson; Chute, John; Gasparetto, Cristina; Horwitz, Mitchell; Long, Gwynn; Rizzieri, David; Sullivan, Keith M.

    2011-01-01

    Purpose: To describe renal shielding techniques and dosimetry in delivering total body irradiation (TBI) to patients with severe systemic sclerosis (SSc) enrolled in a hematopoietic stem cell transplant protocol. Methods and Materials: The Scleroderma: Cyclophosphamide or Transplantation (SCOT) protocol uses a lymphoablative preparative regimen including 800 cGy TBI delivered in two 200-cGy fractions twice a day before CD34 + selected autologous hematopoietic stem cell transplantation. Lung and kidney doses are limited to 200 cGy to protect organs damaged by SSc. Kidney block proximity to the spinal cord was investigated, and guidelines were developed for acceptable lumbar area TBI dosing. Information about kidney size and the organ shifts from supine to standing positions were recorded using diagnostic ultrasound (US). Minimum distance between the kidney blocks (dkB) and the lumbar spine region dose was recorded, and in vivo dosimetry was performed at several locations to determine the radiation doses delivered. Results: Eleven patients were treated at our center with an anteroposterior (AP)/posteroanterior (PA) TBI technique. A 10% to 20% dose inhomogeneity in the lumbar spine region was achieved with a minimum kidney block separation of 4 to 5 cm. The average lumbar spine dose was 179.6 ± 18.1 cGy, with an average dkB of 5.0 ± 1.0 cm. Kidney block shield design was accomplished using a combination of US and noncontrast computerized tomography (CT) or CT imaging alone. The renal US revealed a wide range of kidney displacement from upright to supine positions. Overall, the average in vivo dose for the kidney prescription point was 193.4 ± 5.1 cGy. Conclusions: The dose to the kidneys can be attenuated while maintaining a 10% to 20% dose inhomogeneity in the lumbar spine area. Kidneys were localized more accurately using both US and CT imaging. With this technique, renal function has been preserved, and the study continues to enroll patients.

  15. MO-B-BRB-00: Three Dimensional Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  16. Secondary standard dosimetry laboratory (SSDL)

    International Nuclear Information System (INIS)

    Md Saion bin Salikin.

    1983-01-01

    A secondary Standard Dosimetry Laboratory has been established in the Tun Ismail Research Centre, Malaysia as a national laboratory for reference and standardization purposes in the field of radiation dosimetry. This article gives brief accounts on the general information, development of the facility, programmes to be carried out as well as other information on the relevant aspects of the secondary standard dosimetry laboratory. (author)

  17. Development of A-bomb survivor dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, G.D.

    1995-12-31

    An all important datum in risk assessment is the radiation dose to individual survivors of the bombings in Hiroshima and Nagasaki. The first set of dose estimates for survivors was based on a dosimetry system developed in 1957 by the Oak Ridge National Laboratory (ORNL). These Tentative 1957 Doses (T57D) were later replaced by a more extensive and refined set of Tentative 1965 Doses (T65D). The T65D system of dose estimation for survivors was also developed at ORNL and served as a basis for risk assessment throughout the 1970s. In the late 1970s, it was suggested that there were serious inadequacies with the T65D system, and these inadequacies were the topic of discussion at two symposia held in 1981. In early 1983, joint US- Japan research programs were established to conduct a thorough review of all aspects of the radiation dosimetry for the Hiroshima and Nagasaki A-bomb survivors. A number of important contributions to this review were made by ORNL staff members. The review was completed in 1986 and a new Dosimetry System 1986 (DS86) was adopted for use. This paper discusses the development of the various systems of A-bomb survivor dosimetry, and the status of the current DS86 system as it is being applied in the medical follow-up studies of the A-bomb survivors and their offspring.

  18. Development of A-bomb survivor dosimetry

    International Nuclear Information System (INIS)

    Kerr, G.D.

    1995-01-01

    An all important datum in risk assessment is the radiation dose to individual survivors of the bombings in Hiroshima and Nagasaki. The first set of dose estimates for survivors was based on a dosimetry system developed in 1957 by the Oak Ridge National Laboratory (ORNL). These Tentative 1957 Doses (T57D) were later replaced by a more extensive and refined set of Tentative 1965 Doses (T65D). The T65D system of dose estimation for survivors was also developed at ORNL and served as a basis for risk assessment throughout the 1970s. In the late 1970s, it was suggested that there were serious inadequacies with the T65D system, and these inadequacies were the topic of discussion at two symposia held in 1981. In early 1983, joint US- Japan research programs were established to conduct a thorough review of all aspects of the radiation dosimetry for the Hiroshima and Nagasaki A-bomb survivors. A number of important contributions to this review were made by ORNL staff members. The review was completed in 1986 and a new Dosimetry System 1986 (DS86) was adopted for use. This paper discusses the development of the various systems of A-bomb survivor dosimetry, and the status of the current DS86 system as it is being applied in the medical follow-up studies of the A-bomb survivors and their offspring

  19. Alanine-ESR dosimetry for radiotherapy IAEA experience

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.; )

    1997-01-01

    At present, the most commonly used transfer dosimeters for radiotherapy applications are TL dosemeters. They are being used for intercomparison between SSDLs (about 70) and the IAEA dosimetry laboratory. However, there are some undesirable characteristics of this dosimetry system. We have a study in progress at the IAEA to evaluate the alanine-ESR systems as an alternative to TLDs. There are several desirable qualities which make alanine an attractive dosemeter. Preliminary data suggest that the alanine-ESR dosimetry system has the potential to replace TLDs for intercomparison amongst SSDLs in the therapy-level dose regions. (Author)

  20. Implementation of high-dose chemical dosimetry for industrial facilities

    International Nuclear Information System (INIS)

    Conceicao, Cirilo Cezar Sant'Anna da

    2006-01-01

    The purpose of this work is the implementation of methodology for high dose measurements using chemical dosimeters in liquid phase, traceable to the international metrology system, and make available in the country, the standard of high-dose to industrial irradiation facilities and research irradiators, trough the quality program with comparative measurements and direct use of the standard dosimeters in routine. The use of these low cost dosimetry systems in industrial irradiation facilities, assists to the certification requirements and it can reduce the costs with dosimetry for approximately 20% of the total dosimetry costs, using these systems in routine measurements and validation process, largely substituting the imported PMMA dosimeters, among others. (author)

  1. Radiation dosimetry activities in the Netherlands

    International Nuclear Information System (INIS)

    Broerse, J.J.; Mijnheer, B.J.

    1986-07-01

    The Netherlands Commission for Radiation Dosimetry (NCS) was officially established on 3 September 1982 with the aim of promoting the appropriate use of dosimetry of ionizing radiation both for scientific research and practical applications. The present report provides a compilation of the dosimetry acitivities and expertise available in the Netherlands, based on the replies to a questionnaire mailed under the auspices of the NCS and might suffer from some incompleteness in specific details. The addresses of the Dutch groups with the names of the scientists are given. Individual scientists, not connected with a scientific group, hospital or organization have not been included in this list. Also the names of commercial firms producing dosimetric systems have been omitted. (Auth.)

  2. Role of dosimetry in radiation processing applications

    International Nuclear Information System (INIS)

    Mehta, Kishor

    2001-01-01

    Today, radiation processing is a growing technology offering potential technological advantages as well as enhanced safety and economy. It is expanding on two fronts: the variety of applications is exploding as well as the sources of radiation. And with that comes the necessary advances in dosimetry. However, the success of the technology still depends on the assertion that the irradiated products are reliable and safe, whether they are health care products or cables and wires. And this is best assured through quality assurance programmes. The key element in QA in radiation processing is a well-characterised, reliable dosimetry that is traceable to the international measurement system. Traceability is the foundation for international acceptance of the irradiated products; and with international trade of irradiated products on the rise, it becomes absolutely critical. It is thus vital that the industry recognises this pivotal position of good dosimetry and the role a national standards laboratory plays in that connection. (author)

  3. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  4. Advances in electron dosimetry of irregular fields

    International Nuclear Information System (INIS)

    Mendez V, J.

    1998-01-01

    In this work it is presented an advance in Electron dosimetry of irregular fields for beams emitted by linear accelerators. At present diverse methods exist which are coming to apply in the Radiotherapy centers. In this work it is proposed a method for irregular fields dosimetry. It will be allow to calculate the dose rate absorbed required for evaluating the time for the treatment of cancer patients. Utilizing the results obtained by the dosimetric system, it has been possible to prove the validity of the method describe for 12 MeV energy and for square field 7.5 x 7.5 cm 2 with percentile error less than 1 % . (Author)

  5. Recent developments in polymer gel dosimetry

    International Nuclear Information System (INIS)

    John Schreiner, L.; Olding, Tim; Holmes, Oliver; McAuley, Kim

    2008-01-01

    Modern radiation therapy particularly with intensity modulation techniques (IMRT) offers the potential to improve patient outcomes by better limiting high doses to the tumour alone. In this presentation we report our progress in developing gel dosimetry with new less toxic dosimeters using a fast commercial optical computed tomography (OCT) scanner. We will demonstrate that these adjustments in the approach to gel dosimetry help facilitate its introduction into clinical use. We will review practical advances in system quality assurance and scatter correction to improve optical CT quantification, and show an example of a clinical implementation of an IGRT treatment validation

  6. Dosimetry and process control for radiation processing

    International Nuclear Information System (INIS)

    Mod Ali, N.

    2002-01-01

    Complete text of publication follows. Accurate radiation dosimetry can provide quality assurance in radiation processing. Considerable relevant experiences in dosimetry by the SSDL-MINT has necessitate the development of methods making measurement at gamma plant traceable to the national standard. It involves the establishment of proper calibration procedure and selection of appropriate transfer system/technique to assure adequate traceability to a primary radiation standard. The effort forms the basis for irradiation process control, the legal approval of the process by the public health authorities (medical product sterilization and food preservation) and the safety and acceptance of the product

  7. Neutron dosimetry in biology

    International Nuclear Information System (INIS)

    Sigurbjoernsson, B.; Smith, H.H.; Gustafsson, A.

    1965-01-01

    To study adequately the biological effects of different energy neutrons it is necessary to have high-intensity sources which are not contaminated by other radiations, the most serious of which are gamma rays. An effective dosimetry must provide an accurate measure of the absorbed dose, in biological materials, of each type of radiation at any reactor facility involved in radiobiological research. A standardized biological dosimetry, in addition to physical and chemical methods, may be desirable. The ideal data needed to achieve a fully documented dosimetry has been compiled by H. Glubrecht: (1) Energy spectrum and intensity of neutrons; (2) Angular distribution of neutrons on the whole surface of the irradiated object; (3) Additional undesired radiation accompanying the neutrons; (4) Physical state and chemical composition of the irradiated object. It is not sufficient to note only an integral dose value (e.g. in 'rad') as the biological effect depends on the above data

  8. Double control systems for human T-cell leukemia virus type 1 by innate and acquired immunity.

    Science.gov (United States)

    Kannagi, Mari; Hasegawa, Atsuhiko; Kinpara, Shuichi; Shimizu, Yukiko; Takamori, Ayako; Utsunomiya, Atae

    2011-04-01

    Human T-cell leukemia virus type 1 (HTLV-1) is the causative retrovirus of adult T-cell leukemia (ATL) and HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP). HTLV-1-specific T-cell responses elicit antitumor and antiviral effects in experimental models, and are considered to be one of the most important determinants of the disease manifestation, since they are activated in HAM/TSP but not in ATL patients. The combination of low T-cell responses and elevated HTLV-1 proviral loads are features of ATL, and are also observed in a subpopulation of HTLV-1 carriers at the asymptomatic stage, suggesting that these features may be underlying risk factors. These risks may potentially be reduced by vaccination to activate HTLV-1-specific T-cell responses. HAM/TSP and ATL patients also differ in their levels of HTLV-1 mRNA expression, which are generally low in vivo but slightly higher in HAM/TSP patients. Our recent study indicated that viral expression in HTLV-1-infected T-cells is suppressed by stromal cells in culture through type-I IFNs. The suppression was reversible after isolation from the stromal cells, mimicking a long-standing puzzling phenomenon in HTLV-1 infection where the viral expression is very low in vivo and rapidly induced in vitro. Collectively, HTLV-1 is controlled by both acquired and innate immunity in vivo: HTLV-1-specific T-cells survey infected cells, and IFNs suppress viral expression. Both effects would contribute to a reduction in viral pathogenesis, although they may potentially influence or conflict with one another. The presence of double control systems for HTLV-1 infection provides a new concept for understanding the pathogenesis of HTLV-1-mediated malignant and inflammatory diseases. © 2011 Japanese Cancer Association.

  9. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual DosimetryWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MAY/JUNE will be available from their usual dispatchers on Tuesday 2 May.Please have your films changed before the 12 May.The colour of the dosimeter valid in is MAY/JUNE is YELLOW.Individual Dosimetry Service will be closed on Friday 28 April.

  10. Nuclear medicine radiation dosimetry

    CERN Document Server

    McParland, Brian J

    2010-01-01

    Complexities of the requirements for accurate radiation dosimetry evaluation in both diagnostic and therapeutic nuclear medicine (including PET) have grown over the past decade. This is due primarily to four factors: growing consideration of accurate patient-specific treatment planning for radionuclide therapy as a means of improving the therapeutic benefit, development of more realistic anthropomorphic phantoms and their use in estimating radiation transport and dosimetry in patients, design and use of advanced Monte Carlo algorithms in calculating the above-mentioned radiation transport and

  11. Outcomes in elderly Danish citizens admitted with community-acquired pneumonia. Regional differences, in a public healthcare system

    DEFF Research Database (Denmark)

    Hedegaard Klausen, Henrik; Petersen, J; Lindhardt, T

    2012-01-01

    OBJECTIVES: To evaluate regional differences in and risk factors for admission, length of stay, mortality, and readmission for community-acquired pneumonia in elderly Danish patients. METHODS: National registry study on elderly Danish citizens with an acute admission in 2009 owing to community....... RESULTS: A total of 11,332 elderly citizens were admitted with community-acquired pneumonia. Mortality during admission and 30-days from discharge were 11.6% and 16.2%, respectively. Readmission rates within 30 days of discharge were 12.3%. There were significantly differences between hospitals in length...

  12. A Comparative Study of Coping Strategies and the Features of Interpersonal Relations and Life Orientations of People with Congenital and Acquired Diseases of the Musculoskeletal System

    Science.gov (United States)

    Romanova, E. V.; Tolkacheva, O. N.

    2016-01-01

    The article presents the results of a comparative study of the features of the coping strategies, life orientations, and interpersonal relations of disabled people with acquired and congenital diseases of the musculoskeletal system. The authors discovered differences in interpersonal behavior in the area of control, and they revealed factors that…

  13. Development of a calorimetric system for electron beam dosimetry in radiation processing; Desenvolvimento de um sistema calorimetrico para dosimetria de feixe de eletrons em processos por radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Banados P, H E

    1994-12-31

    A calorimetric system for electron beam dosimetry in radiation processing was developed. The system is composed of a graphite core calorimeter, the temperature measuring and electrical calibrating instrumentation, a microcomputer and the software for the system automation. The research aimed at the optimization of the project parameters, the development of advanced methodologies for calibrating the temperature sensor, the determination of the thermal capacity as a function of the temperature, the measurement of the absorbed dose, and the development of the software needed for the system operation. The operating range extends from 0.1 kGy to 30 kGy. The uncertainty in the measurement of the absorbed dose was estimated to be {+-} 1.8% at the 95% confidence level. Comparative tests of the absorbed dose measurements were made using the IPEN electron accelerator. The results obtained showed an excellent agreement between the absorbed dose determined by the calorimeter and the absorbed dose calculated from the nominal power delivered by the accelerator. (author). 67 refs, 63 figs, 2 tabs.

  14. Radiation dosimetry and standards at the austrian dosimetry laboratory

    International Nuclear Information System (INIS)

    Leitner, A.

    1984-10-01

    The Austrian Dosimetry Laboratory, established and operated in cooperation between the Austrian Research Center Seibersdorf and the Federal Office of Metrology and Surveying (Bundesamt and Eich- und Vermessungswesen) maintains the national primary standards for radiation dosimetry. Furthermore its tasks include routine calibration of dosemeters and dosimetric research. The irradiation facilities of the laboratory comprise three X-ray machines covering the voltage range from 5 kV to 420 kV constant potential, a 60 Co teletherapy unit, a circular exposure system for routine batch calibration of personnel dosemeters with four gamma ray sources ( 60 Co and 137 Cs) and a reference source system with six gamma ray sources ( 60 Co and 137 Cs). In addition a set of calibrated beta ray sources are provided ( 147 Pm, 204 Tl and 90 Sr). The dosimetric equipment consists of three free-air parallelplate ionization chambers serving as primary standards of exposure for the X-ray energy region, graphite cavity chambers with measured volume as primary standards for the gamma radiation of 137 Cs and 60 Co as well as different secondary standard ionization chambers covering the dose rate range from the natural background level up to the level of modern therapy accelerators. In addition for high energy photon and electron radiation a graphite calorimeter is provided as primary standard of absorbed dose. The principle experimental set-ups for the practical use of the standards are presented and the procedures for the calibration of the different types of dosemeters are described. (Author)

  15. Dosimetry of radiolabeled monoclonal antibodies used for therapy

    International Nuclear Information System (INIS)

    Myers, M.J.; Hooker, G.R.; Epenetos, A.A.

    1986-01-01

    The present state of radiotherapy using labeled antibodies is reviewed. From the point of view of dosimetry, antibody therapy does not seem to have reached a stable and practicable enough state to provide an input to any but rather tentative dosimetry models. These, therefore, should not be taken too far until the problems of antibody targeting have been more fully developed. Some of the instrumental techniques for acquiring dosimetric data under clinical conditions are discussed as are some of the techniques of therapy in use today. 8 references, 3 figures

  16. Iodine-124 PET dosimetry in differentiated thyroid cancer: recovery coefficient in 2D and 3D modes for PET(/CT) systems

    Energy Technology Data Exchange (ETDEWEB)

    Jentzen, Walter; Freudenberg, Lutz; Brandau, Wolfgang; Bockisch, Andreas [Universitaet Duisburg-Essen, Klinik fuer Nuklearmedizin, Essen (Germany); Weise, Reiner; Burchert, Wolfgang [Institut fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Kupferschlaeger, Juergen; Bares, Ronald [Universitaet Tuebingen, Klinik fuer Nuklearmedizin, Tuebingen (Germany)

    2008-03-15

    This study evaluated the absolute quantification of iodine-124 ({sup 124}I) activity concentration with respect to the use of this isotope for dosimetry before therapies with {sup 131}I or {sup 131}I-labeled radiotherapeuticals. The recovery coefficients of positron emission tomography(/computed tomography) PET(/CT) systems using {sup 124}I were determined using phantoms and then validated under typical conditions observed in differentiated thyroid cancer (DTC) patients. Transversal spatial resolution and recovery measurements with {sup 124}I and with fluorine-18 ({sup 18}F) as the reference were performed using isotope-containing line sources embedded in water and six isotope-containing spheres 9.7 to 37.0 mm in diameter placed in water-containing body and cylinder phantoms. The cylinder phantom spheres were filled with {sup 18}F only. Measurements in two-dimensional (2D) and three-dimensional (3D) modes were performed using both stand-alone PET (EXACT HR{sup +}) and combined PET/CT (BIOGRAPH EMOTION DUO) systems. Recovery comparison measurements were additionally performed on a GE ADVANCE PET system using the cylinder phantom. The recovery coefficients were directly determined using the activity concentration of circular regions of interest divided by the prepared activity concentration determined by the dose calibrator. The recovery correction method was validated using three consecutive scans of the body phantom under our {sup 124}I PET(/CT) protocol for DTC patients. Compared with that of {sup 18}F, transversal spatial resolution of {sup 124}I was slightly, but statistically significantly degraded (7.4 mm vs. 8.3 mm, P<0.002). Using the body phantom, recovery was lower for {sup 124}I than for {sup 18}F in both 2D and 3D modes. The {sup 124}I recovery coefficient of the largest sphere was significantly higher in 2D than in 3D mode (81% vs. 75%, P=0.03). Remarkably, the {sup 18}F recovery coefficient for the largest sphere significantly deviated from unity

  17. Personnel photographic film dosimetry

    International Nuclear Information System (INIS)

    Keirim-Markus, I.B.

    1981-01-01

    Technology of personnel photographic film dosimetry (PPD) based on the photographic effect of ionizing radiation is described briefly. Kinds of roentgen films used in PPD method are enumerated, compositions of a developer and fixing agents for these films are given [ru

  18. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  19. Dosimetry of pion beams

    International Nuclear Information System (INIS)

    Dicello, J.F.

    1975-01-01

    Negative pion beams are probably the most esoteric and most complicated type of radiation which has been suggested for use in clinical radiotherapy. Because of the limited availability of pion beams in the past, even to nuclear physicists, there exist relatively fewer basic data for this modality. Pion dosimetry is discussed

  20. High frequency electromagnetic dosimetry

    CERN Document Server

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.