WorldWideScience

Sample records for dosimetric range assessment

  1. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  2. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: gas@cdtn.br, e-mail: pls@cdtn.br, e-mail: fcp@cdtn.br, e-mail: lcmb@cdtn.br, e-mail: pabloag@cdtn.br

    2009-07-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  3. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    International Nuclear Information System (INIS)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade

    2009-01-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  4. Dosimetric assessment of the PRESAGE dosimeter for a proton pencil beam

    International Nuclear Information System (INIS)

    Wuu, C-S; Qian, X; Xu, Y; Adamovics, J; Cascio, E; Lu, H-M

    2013-01-01

    The objective of this study is to assess the feasibility of using PRESAGE dosimeters for proton pencil beam dosimetry. Two different formulations of phantom materials were tested for their suitability in characterizing a single proton pencil beam. The dosimetric response of PRESAGE was found to be linear up to 4Gy. First-generation optical CT scanner, OCTOPUS TM was used to implement dose distributions for proton pencil beams since it provides most accurate readout. Percentage depth dose curves and beam profiles for two proton energy, 110 MeV, and 93 MeV, were used to evaluate the dosimetric performance of two PRESAGE phantom formulas. The findings from this study show that the dosimetric properties of the phantom materials match with basic physics of proton beams.

  5. Characterization of natural topaz for dosimetric applications in the therapeutic range

    International Nuclear Information System (INIS)

    Souza, Divanizia do Nascimento

    2002-01-01

    The thermoluminescence (TL) and the thermally stimulated exoelectron emission of Brazilian natural topaz samples from Minas Gerais were analysed aiming the use of this mineral for dosimetric applications. Topaz is an aluminium fluorosilicate with a fairly constant chemical composition of Al 2 SiO 4 (F,OH) 2 . The major variation in the structure among different samples is related to the OH/F concentration ratio. In the present work, samples cut from rolled pebbles, powdered samples and composites were used. The composites (dosimeters) were prepared with powdered topaz embedded in powdered Teflon or glass. The dosimetric characterization of the composites showed that the dosimeters present a linear response in the range of therapeutic doses, slow isothermic fading and a strong TL dependence with radiation energy. The TL was also combined with the X-ray diffraction, infrared and Raman spectroscopic techniques to identify the charge carrier traps and those of the recombination centres, that are essential aspects to understand the processes of light emission in natural colourless topaz. It was observed that the main charge trapping centers in the topaz are due to various OH-related defects, and that the thermal treatments can change the concentration of the recombination centers. Implantations with chromium, aluminium and iron ions into colourless samples were performed, and they were efficient to produce TL modifications in topaz. (author)

  6. Dosimetric properties of the 'Pille' portable, wide dose range TLD reader

    International Nuclear Information System (INIS)

    Szabo, P.P.; Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.

    1986-01-01

    The dosimetric properties of a portable TLD reader are described. The TLD system named 'Pille' or 'moth' consists of a lightweight battery-operated portable TLD reader and its CaSO 4 :Dy bulb dosemeters. The reproducibility of the TLD system at constant temperature was found to be better than + -2%, and the mean time between failures exceeded 5 years. The dose range of the system is wide, covering more than 6 orders of magnitude, from 5 μGy to 10 Gy. The energy dependence of the CaSO 4 :Dy bulb dosemeters is less than + - 20% above 100 keV in the energy compensation capsules. Without additional annealing, the bulb dosemeters can be re-used at least 100 times, which is an important aspect during in situ measurements. (author)

  7. Assessment of dosimetrical performance in 11 Varian a-Si500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Kavuma, Awusi; Glegg, Martin; Currie, Garry; Elliott, Alex

    2008-01-01

    Dosimetrical characteristics of 11 Varian a-Si-500 electronic portal imaging devices (EPIDs) in clinical use for periods ranging between 10 and 86 months were investigated for consistency of performance and portal dosimetry implications. Properties studied include short-term reproducibility, signal linearity with monitor units, response to reference beam, signal uniformity across the detector panel, signal dependence on field size, dose-rate influence, memory effects and image profiles as a function of monitor units. The EPID measurements were also compared with those of the ionization chambers' to ensure stability of the linear accelerators. Depending on their clinical installation date, the EPIDs were interfaced with one of the two different acquisition control software packages, IAS2/IDU-II or IAS3/IDU-20. Both the EPID age and image acquisition system influenced the dosimetric characteristics with the newer version (IAS3 with IDU-20) giving better data reproducibility and linearity fit than the older version (IAS2 with IDU-II). The relative signal response (uniformity) after 50 MU was better than 95% of the central value and independent of detector. Sensitivity for all EPIDs reduced continuously with increasing dose rates for the newer image acquisition software. In the dose-rate range 100-600 MU min -1 , the maximum variation in sensitivity ranged between 1 and 1.8% for different EPIDs. For memory effects, the increase in the measured signal at the centre of the irradiated field for successive images was within 1.8% and 1.0% for the older and newer acquisition systems, respectively. Image profiles acquired at a lower MU in the radial plane (gun-target) had gradients in measured pixel values of up to 25% for the older system. Detectors with software/hardware versions IAS3/IDU-20 have a high degree of accuracy and are more suitable for routine quantitative IMRT dosimetrical verification.

  8. Prospective assessment of dosimetric/physiologic-based models for predicting radiation pneumonitis

    International Nuclear Information System (INIS)

    Kocak, Zafer; Borst, Gerben R.; Zeng Jing; Zhou Sumin; Hollis, Donna R.; Zhang Junan; Evans, Elizabeth S.; Folz, Rodney J.; Wong, Terrence; Kahn, Daniel; Belderbos, Jose S.A.; Lebesque, Joos V.; Marks, Lawrence B.

    2007-01-01

    Purpose: Clinical and 3D dosimetric parameters are associated with symptomatic radiation pneumonitis rates in retrospective studies. Such parameters include: mean lung dose (MLD), radiation (RT) dose to perfused lung (via SPECT), and pre-RT lung function. Based on prior publications, we defined pre-RT criteria hypothesized to be predictive for later development of pneumonitis. We herein prospectively test the predictive abilities of these dosimetric/functional parameters on 2 cohorts of patients from Duke and Netherlands Cancer Institute (NKI). Methods and Materials: For the Duke cohort, 55 eligible patients treated between 1999 and 2005 on a prospective IRB-approved study to monitor RT-induced lung injury were analyzed. A similar group of patients treated at the NKI between 1996 and 2002 were identified. Patients believed to be at high and low risk for pneumonitis were defined based on: (1) MLD; (2) OpRP (sum of predicted perfusion reduction based on regional dose-response curve); and (3) pre-RT DLCO. All doses reflected tissue density heterogeneity. The rates of grade ≥2 pneumonitis in the 'presumed' high and low risk groups were compared using Fisher's exact test. Results: In the Duke group, pneumonitis rates in patients prospectively deemed to be at 'high' vs. 'low' risk are 7 of 20 and 9 of 35, respectively; p = 0.33 one-tailed Fisher's. Similarly, comparable rates for the NKI group are 4 of 21 and 6 of 44, respectively, p = 0.41 one-tailed Fisher's. Conclusion: The prospective model appears unable to accurately segregate patients into high vs. low risk groups. However, considered retrospectively, these data are consistent with prior studies suggesting that dosimetric (e.g., MLD) and functional (e.g., PFTs or SPECT) parameters are predictive for RT-induced pneumonitis. Additional work is needed to better identify, and prospectively assess, predictors of RT-induced lung injury

  9. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  10. Dosimetric characterization of radionuclides for systemic tumor therapy: Influence of particle range, photon emission, and subcellular distribution

    International Nuclear Information System (INIS)

    Uusijaervi, Helena; Bernhardt, Peter; Ericsson, Thomas; Forssell-Aronsson, Eva

    2006-01-01

    Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability of toxicity in, e.g., the bone marrow. The aim of this study was to investigate the dosimetric properties according to particle range, photon emission, and subcellular radionuclide distribution, of a selection of radionuclides used or proposed for radionuclide therapy, and to investigate the possibility of dividing radionuclides into groups according to their dosimetric properties. The absorbed dose rate to the tumors divided by the absorbed dose rate to the normal tissue (TND) was estimated for different tumor sizes in a mathematical model of the human body. The body was simulated as a 70-kg ellipsoid and the tumors as spheres of different sizes (1 ng-100 g). The radionuclides were either assumed to be uniformly distributed throughout the entire tumor and normal tissue, or located in the nucleus or the cytoplasm of the tumor cells and on the cell membrane of the normal cells. Fifty-nine radionuclides were studied together with monoenergetic electrons, positrons, and alpha particles. The tumor and normal tissue were assumed to be of water density. The activity concentration ratio between the tumor and normal tissue was assumed to be 25. The radionuclides emitting low-energy electrons combined with a low photon contribution, and the alpha emitters showed high TND values for most tumor sizes. Electrons with higher energy gave reduced TND values for small tumors, while a higher photon contribution reduced the TND values for large tumors. Radionuclides with high photon contributions showed low TND value for all tumor sizes studied. The radionuclides studied could be divided into four main groups according to their TND values: beta emitters, Auger electron

  11. Radiochromic film in the dosimetric verification of intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Zhou Yingjuan; Huang Shaomin; Deng Xiaowu

    2007-01-01

    Objective: Objective To investigate the dose-response behavior of a new type of radio- chromic film( GAFCHROMIC EBT) and explore the clinical application means and precision of dosage measurement, which can be applied for: (1) plan-specific dosimetric verification for intensity modulated radiation therapy, (2) to simplify the process of quality assurance using traditional radiographic film dosimetric system and (3) to establish a more reliable, more efficient dosimetric verification system for intensity modulated radiation therapy. Methods: (1) The step wedge calibration technique was used to calibrate EBT radiochromic film and EDR2 radiographic film. The dose characteristics, the measurement consistency and the quality assurance process between the two methods were compared. (2) The in-phantom dose-measurement based verification technique has been adopted. Respectively, EBT film and EDR2 film were used to measure the same dose plane of IMRT treatment plans. The results of the dose map, dose profiles and iso- dose curves were compared with those calculated by CORVUS treatment planning system to evaluate the function of EBT film for dosimetric verification for intensity modulated radiation therapy. Results: (1) Over the external beam dosimetric range of 0-500 cGy, EBT/VXR-16 and EDR2/VXR-16 film dosimetric system had the same measurement consistency with the measurement variability less then 0.70%. The mean measurement variability of these two systems was 0.37% and 0.68%, respectively. The former proved to be the superior modality at measurement consistency, reliability, and efficiency over dynamic clinical dose range , furthermore, its quality assurance showed less process than the latter. (2) The dosimetric verification of IMRT plane measured with EBT film was quite similar to that with EDR2 film which was processed under strict quality control. In a plane of the phantom, the maximal dose deviation off axis between EBT film measurement and the TPS calculation was

  12. Gamma dosimetric parameters in some skeletal muscle relaxants

    Science.gov (United States)

    Manjunatha, H. C.

    2017-09-01

    We have studied the attenuation of gamma radiation of energy ranging from 84 keV to 1330 keV (^{170}Tm, ^{22}Na,^{137}Cs, and ^{60}Co) in some commonly used skeletal muscle relaxants such as tubocurarine chloride, gallamine triethiodide, pancuronium bromide, suxamethonium bromide and mephenesin. The mass attenuation coefficient is measured from the attenuation experiment. In the present work, we have also proposed the direct relation between mass attenuation coefficient (μ /ρ ) and mass energy absorption coefficient (μ _{en}/ρ ) based on the nonlinear fitting procedure. The gamma dosimetric parameters such as mass energy absorption coefficient (μ _{en}/ρ ), effective atomic number (Z_{eff}), effective electron density (N_{el}), specific γ-ray constant, air kerma strength and dose rate are evaluated from the measured mass attentuation coefficient. These measured gamma dosimetric parameters are compared with the theoretical values. The measured values agree with the theoretical values. The studied gamma dosimetric values for the relaxants are useful in medical physics and radiation medicine.

  13. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J. [M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States); MGS Research, Inc., Madison, Connecticut 06443 (United States)

    2010-05-15

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  14. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    International Nuclear Information System (INIS)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J.

    2010-01-01

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  15. Study of a new dosimetric radio-thermoluminescent systems

    International Nuclear Information System (INIS)

    Cazac, T.C.

    1980-01-01

    This is the first Romanian study to investigate conditions to obtain the radio-thermo-luminescent systems: MgB 4 O 7 :A(A-Nd,Sm,Eu,Dy,Tb,Dy+Sm and Tb+Sm) MgF 2 A (A=Mn,Dy,Tb,Sm,Li), their essential dosimetric characters, as well as the (MgF 2 =Mn) thermophosphorus mixture with a ( 6 LiF) lithium target. An investigation was developed upon a new category of radio-thermoluminescent detectors with low radiation energy dependence and fading, magnesjum boride activated by several elements of the lanthanides class (Nd,Sm,Eu,Dy,Tb). A new radio-thermoluminescent dosimetric system with high sensitivity and moderate dependence on energy radiation - (Mnsup(2+)) manganese activated magnesium fluoride - was also studied. The author explored application of investigated detectors MgF 2 =Mn, MgB 4 O 7 =Dy and MgB 4 O 7 :Tb in neutron dosimetry in complex gamma-neutron fields. It is deemed that by using the dosimetric systems reported in the thesis in order to measure gamma, beta and neutron radiation doses, dosimetric control can be ensured both in professional dosimetry and in nuclear accident dosimetry, as well as in various basic and applicative investigations. A modest contribution is thus made towards achieving the national nuclear program through an extension of the thermophosphorus range with practical applications in nuclear radiation dosimetry. (author)

  16. Dosimetric system for prolonged manned flights

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Kovalev, E.E.; Sakovich, V.A.; Deme, Sh.; Fekher, I.; Nguen, V.D.

    1991-01-01

    Comments for the All-Union state standard 25645.202-83 named Radiation safety of a spacecraft crew during space flight. Requirements for personnel dosimetric control, are given. Devices for the dosimetric control used in manned space flights nowadays are reviewed. The performance principle and structure of the FEDOR dosimetric complex under development are discussed

  17. Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit–based Dose Deformation Framework

    Energy Technology Data Exchange (ETDEWEB)

    Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Santhanam, Anand; Neylon, John; Min, Yugang; Armstrong, Tess; Sheng, Ke [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Staton, Robert J.; Pukala, Jason [Department of Radiation Oncology, UF Health Cancer Center - Orlando Health, Orlando, Florida (United States); Pham, Andrew; Low, Daniel A.; Lee, Steve P. [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Steinberg, Michael; Manon, Rafael [Department of Radiation Oncology, UF Health Cancer Center - Orlando Health, Orlando, Florida (United States); Chen, Allen M.; Kupelian, Patrick [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States)

    2015-06-01

    Purpose: The purpose of this study was to systematically monitor anatomic variations and their dosimetric consequences during intensity modulated radiation therapy (IMRT) for head and neck (H&N) cancer by using a graphics processing unit (GPU)-based deformable image registration (DIR) framework. Methods and Materials: Eleven IMRT H&N patients undergoing IMRT with daily megavoltage computed tomography (CT) and weekly kilovoltage CT (kVCT) scans were included in this analysis. Pretreatment kVCTs were automatically registered with their corresponding planning CTs through a GPU-based DIR framework. The deformation of each contoured structure in the H&N region was computed to account for nonrigid change in the patient setup. The Jacobian determinant of the planning target volumes and the surrounding critical structures were used to quantify anatomical volume changes. The actual delivered dose was calculated accounting for the organ deformation. The dose distribution uncertainties due to registration errors were estimated using a landmark-based gamma evaluation. Results: Dramatic interfractional anatomic changes were observed. During the treatment course of 6 to 7 weeks, the parotid gland volumes changed up to 34.7%, and the center-of-mass displacement of the 2 parotid glands varied in the range of 0.9 to 8.8 mm. For the primary treatment volume, the cumulative minimum and mean and equivalent uniform doses assessed by the weekly kVCTs were lower than the planned doses by up to 14.9% (P=.14), 2% (P=.39), and 7.3% (P=.05), respectively. The cumulative mean doses were significantly higher than the planned dose for the left parotid (P=.03) and right parotid glands (P=.006). The computation including DIR and dose accumulation was ultrafast (∼45 seconds) with registration accuracy at the subvoxel level. Conclusions: A systematic analysis of anatomic variations in the H&N region and their dosimetric consequences is critical in improving treatment efficacy. Nearly real

  18. Multi-subject atlas-based auto-segmentation reduces interobserver variation and improves dosimetric parameter consistency for organs at risk in nasopharyngeal carcinoma: A multi-institution clinical study

    International Nuclear Information System (INIS)

    Tao, Chang-Juan; Yi, Jun-Lin; Chen, Nian-Yong; Ren, Wei; Cheng, Jason; Tung, Stewart; Kong, Lin; Lin, Shao-Jun; Pan, Jian-Ji; Zhang, Guang-Shun; Hu, Jiang; Qi, Zhen-Yu; Ma, Jun; Lu, Jia-De; Yan, Di; Sun, Ying

    2015-01-01

    Background and purpose: To assess whether consensus guideline-based atlas-based auto-segmentation (ABAS) reduces interobserver variation and improves dosimetric parameter consistency for organs at risk (OARs) in nasopharyngeal carcinoma (NPC). Materials and methods: Eight radiation oncologists from 8 institutes contoured 20 OARs on planning CT images of 16 patients via manual contouring and manually-edited ABAS contouring. Interobserver variation [volume coefficient of variation (CV), Dice similarity coefficient (DSC), three-dimensional isocenter difference (3D-ICD)] and dosimetric parameters were compared between the two methods of contouring for each OAR. Results: Interobserver variation was significant for all OARs in manual contouring, resulting in significant dosimetric parameter variation (P < 0.05). Edited ABAS significantly improved multiple metrics and reduced dosimetric parameter variation for most OARs; brainstem, spinal cord, cochleae, temporomandibular joint (TMJ), larynx and pharyngeal constrictor muscle (PCM) obtained most benefit (range of mean DSC, volume CV and main ICD values was 0.36–0.83, 12.1–84.3%, 2.2–5.0 mm for manual contouring and 0.42–0.86, 7.2–70.6%, 1.2–3.5 mm for edited ABAS contouring, respectively; range of dose CV reduction: 1.0–3.0%). Conclusion: Substantial objective interobserver differences occur during manual contouring, resulting in significant dosimetric parameter variation. Edited ABAS reduced interobserver variation and improved dosimetric parameter consistency, particularly for brainstem, spinal cord, cochleae, TMJ, larynx and PCM

  19. First approval procedure of the TL dosimetric service of the NPP in Slovenia

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Pucelj, B.; Stuhec, M.; Zdesar, U.

    2001-01-01

    The individual dosimetry of exposed workers in a NPP is one of the essential parts which demonstrates the radiation protection standards achieved in a facility. According to the current legislation the Ministry of Health of the Republic of Slovenia has the authority to grant approvals to personal dosimetric services which perform the dosimetric monitoring of workers in Slovenia. Due to the fact that the detailed approval procedure is not given in national regulations, the Ministry of Health in 2000 established a group of experts with the task to prepare technical and organising requirements for such approval. Based on international documents [1,2,3] the Approval procedure for the thermoluminescence dosimetric (TL) services was created. Following this procedure the assessment of the TL dosimetric service in the NPP was performed. The problems related to the technical and organising requirements with the emphasise on the QA/QC criteria of the TL dosimetric service will be discussed.(author)

  20. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Paradis, Eric, E-mail: eparadis@umich.edu [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Cao, Yue [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Department of Biomedical Engineering, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Lawrence, Theodore S.; Tsien, Christina; Feng, Mary; Vineberg, Karen; Balter, James M. [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States)

    2015-12-01

    Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.

  1. Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Baptista, Mariana, E-mail: marianabaptista@ctn.ist.utl.pt; Di Maria, Salvatore; Barros, Sílvia; Vaz, Pedro [Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Estrada Nacional 10, km 139,7, Bobadela LRS 2695-066 (Portugal); Figueira, Catarina [Centre for Plasma Physics, School of Mathematics and Physics, Queen’s University, Belfast BT7 1NN (United Kingdom); Sarmento, Marta; Orvalho, Lurdes [Serviço de Imagiologia, Hospital da Luz, Avenida Lusíada, 100, Lisboa 1500-650 (Portugal)

    2015-07-15

    Purpose: Due to its capability to more accurately detect deep lesions inside the breast by removing the effect of overlying anatomy, digital breast tomosynthesis (DBT) has the potential to replace the standard mammography technique in clinical screening exams. However, the European Guidelines for DBT dosimetry are still a work in progress and there are little data available on organ doses other than to the breast. It is, therefore, of great importance to assess the dosimetric performance of DBT with respect to the one obtained with standard digital mammography (DM) systems. The aim of this work is twofold: (i) to study the dosimetric properties of a combined DBT/DM system (MAMMOMAT Inspiration Siemens{sup ®}) for a tungsten/rhodium (W/Rh) anode/filter combination and (ii) to evaluate organs doses during a DBT examination. Methods: For the first task, measurements were performed in manual and automatic exposure control (AEC) modes, using two homogeneous breast phantoms: a PMMA slab phantom and a 4 cm thick breast-shaped rigid phantom, with 50% of glandular tissue in its composition. Monte Carlo (MC) simulations were performed using Monte Carlo N-Particle eXtended v.2.7.0. A MC model was implemented to mimic DM and DBT acquisitions for a wide range of x-ray spectra (24 –34 kV). This was used to calculate mean glandular dose (MGD) and to compute series of backscatter factors (BSFs) that could be inserted into the DBT dosimetric formalism proposed by Dance et al. Regarding the second aim of the study, the implemented MC model of the clinical equipment, together with a female voxel phantom (“Laura”), was used to calculate organ doses considering a typical DBT acquisition. Results were compared with a standard two-view mammography craniocaudal (CC) acquisition. Results: Considering the AEC mode, the acquisition of a single CC view results in a MGD ranging from 0.53 ± 0.07 mGy to 2.41 ± 0.31 mGy in DM mode and from 0.77 ± 0.11 mGy to 2.28 ± 0.32 mGy in DBT mode

  2. SU-F-J-128: Dosimetric Impact of Esophagus Motion in Spine Stereotactic Body Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J; Wang, X; Zhao, Z; Yang, J; Zhang, Y; Court, L; Li, J; Brown, P; Ghia, A [MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: Acute esophageal toxicity is a common side effect in spine stereotactic body radiotherapy (SBRT). The respiratory motion may alter esophageal position from the planning scan resulting in excessive esophageal dose. Here we assessed the dosimetric impact resulting from the esophageal motion using 4DCT. Methods: Nine patients treated to their thoracic spines in one fraction of 24 Gy were identified for this study. The original plan on a free breathing CT was copied to each phase image of a 4DCT scan, recalculated, scaled, and accumulated to the free breathing CT using deformable image registration. A segment of esophagus was contoured in the vicinity of treatment target. Esophagus dose volume histogram (DVH) was generated for both the original planned dose and the accumulated 4D dose for comparison. In parallel, we performed a chained deformable registration of 4DCT phase images to estimate the motion magnitude of the esophagus in a breathing cycle. We examined the correlation between the motion magnitude and the dosimetric deviation. Results: The esophageal motion mostly exhibited in the superior-inferior direction. The cross-sectional motion was small. Esophagus motion at T1 vertebra level (0.7 mm) is much smaller than that at T11 vertebra level (6.5 mm). The difference of Dmax between the original and 4D dose distributions ranged from 9.1 cGy (esophagus motion: 5.6 mm) to 231.1 cGy (esophagus motion: 3.1 mm). The difference of D(5cc) ranged from 5 cGy (esophagus motion: 3.1 mm) to 85 cGy (esophagus motion: 3.3 mm). There was no correlation between the dosimetric deviation and the motion magnitude. The V(11.9Gy)<5cc constraint was met for each patient when examining the DVH calculated from the 4D dose. Conclusion: Respiratory motion did not result in substantial dose increase to esophagus in spine SBRT. 4DCT simulation may not be necessary with regards to esophageal dose assessment.

  3. Dosimetric effects of edema in permanent prostate seed implants: a rigorous solution

    International Nuclear Information System (INIS)

    Chen Zhe; Yue Ning; Wang Xiaohong; Roberts, Kenneth B.; Peschel, Richard; Nath, Ravinder

    2000-01-01

    Purpose: To derive a rigorous analytic solution to the dosimetric effects of prostate edema so that its impact on the conventional pre-implant and post-implant dosimetry can be studied for any given radioactive isotope and edema characteristics. Methods and Materials: The edema characteristics observed by Waterman et al (Int. J. Rad. Onc. Biol. Phys, 41:1069-1077; 1998) was used to model the time evolution of the prostate and the seed locations. The total dose to any part of prostate tissue from a seed implant was calculated analytically by parameterizing the dose fall-off from a radioactive seed as a single inverse power function of distance, with proper account of the edema-induced time evolution. The dosimetric impact of prostate edema was determined by comparing the dose calculated with full consideration of prostate edema to that calculated with the conventional dosimetry approach where the seed locations and the target volume are assumed to be stationary. Results: A rigorous analytic solution on the relative dosimetric effects of prostate edema was obtained. This solution proved explicitly that the relative dosimetric effects of edema, as found in the previous numerical studies by Yue et. al. (Int. J. Radiat. Oncol. Biol. Phys. 43, 447-454, 1999), are independent of the size and the shape of the implant target volume and are independent of the number and the locations of the seeds implanted. It also showed that the magnitude of relative dosimetric effects is independent of the location of dose evaluation point within the edematous target volume. It implies that the relative dosimetric effects of prostate edema are universal with respect to a given isotope and edema characteristic. A set of master tables for the relative dosimetric effects of edema were obtained for a wide range of edema characteristics for both 125 I and 103 Pd prostate seed implants. Conclusions: A rigorous analytic solution of the relative dosimetric effects of prostate edema has been

  4. SU-F-T-565: Assessment of Dosimetric Accuracy for a 3D Gel-Based Dosimetry Service

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, B; Lam, K; Moran, J [University Michigan Medical Center, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: To assess the 3D dosimetric accuracy when using a mail-in service for square and stereotactic fields in a clinical environment. Methods: The 3D dosimetry mail-in service (3DDaaS), offered by Modus QA (London, ON), was used to measure dose distributions from a 6 MV beam of a Varian Clinac. Plastic jars filled with radiosensitive ClearView™ gel were received, CT scanned (for registration and density information), irradiated, and then mailed back to the manufacturer for optical CT readout. Three square field irradiations (2×2, 4×4, and 10×10 cm{sup 2}) were performed with jars immobilized in a water tank, and a composite small-field stereotactic delivery was performed using an in-air holder. Dosimetric properties of the gel were quantified within the 25–50 Gy dose range using 3D optical attenuation (OA) distributions provided by the manufacturer. OA was normalized to 100% at the position of isocenter, which received 40Gy. Percentage depth dose, profiles, and 3D gamma distributions (3%/1mm criteria) were calculated to quantify feasibility for relative dosimetry. Results: Mean CT-measured density in the central (3×3×3) cm{sup 3} gel region was 40 ± 3 HU, indicating good homogeneity and near-water-equivalence. Measured and calculated central axis doses agreed to within ±3% in the 25–50 Gy dose range. For the square field irradiations, dose profiles agreed to within 1mm. Gamma analysis of the composite irradiation yielded 99.8%, 91.4%, and 79.1% passing rates for regions receiving at least 10, 5, and 2 Gy, respectively, indicating feasibility for use in high-dose regions. Absolute response varied by up to 16% between jars, indicating limitations for absolute dosimetry under the mail-in conditions. Conclusion: 3DDaaS is a novel near-water-equivalent dosimetry system accurate to within 3% dose and 1mm 3D spatial resolution, and is straightforward to use in a clinical setting. Future investigations are warranted to improve dosimeter response in low

  5. ESR dosimetric properties of modern coral reef

    Energy Technology Data Exchange (ETDEWEB)

    Sharaf, M.A. E-mail: mokhtar_sharaf@yahoo.com; Hassan, Gamal M

    2004-06-01

    Modern coral reef samples from Egypt were irradiated with {sup 60}Co{gamma}-rays to study radicals for dosimetric materials with electron spin resonance (ESR). The ESR spectrum for the radical species in unirradiated coral is characterized by four signals with spectroscopic splitting factors of g=2.0056, 2.0030, 2.0006 and 1.997. The signal at g=2.0006{+-}0.0005 is ascribed to free rotation CO{sub 2}{sup -} radicals and used as a dosimetric one. The response to {gamma}-ray doses ranging from 5 to 10{sup 3} Gy and the thermal stability has been studied. The number of free radicals per 100 eV (G-value) was found to be 0.45 {+-} 0.1 and 0.9 {+-} 0.18 for coral and alanine, respectively. The lifetime of radicals and the activation energy were estimated from Arrhenius plots to be approximately 8 x 10{sup 5} {+-} 1.6 x 10{sup 5} years, and 1.12 eV, respectively.

  6. Personal dosimetric monitoring in Ukraine: current status and further development

    International Nuclear Information System (INIS)

    Chumak, V. V.; Musijachenkom, A. V.; Boguslavskaya, A. I.

    2003-01-01

    Presently Ukraine has mixed system for dosimetric monitoring. Nuclear power plants and some major nuclear facilities have their own dosimetry services, which are responsible for regular dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by dosimetry laboratories affiliated to the territorial authorities for sanitary and epidemiology supervision. In 2002-2003 Ukrainian Ministry of Health performed survey of the status of dosimetric monitoring and inventory of critical groups requiring such monitoring. Dosimetry services in Ukraine cover about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca.12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services operate in 13 of 24 regions of Ukraine, using DTU-01 manual TLD readers produced with one exception in 1988-1990. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38% to 100% depending on the region. Personnel of nuclear power plants (about 16,400 workers) is monitored by their own dosimetry services achieving absolute coverage of the main staff and temporary workers. Current inadequate status of dosimetric monitoring infrastructure in Ukraine demands an urgent elaboration of the united state system for monitoring and recording of individual doses. The proposed plan would allows to bring dosimetry infrastructure in Ukraine to the modern state which would be compatible with existing and future European and international radiation protection networks. Unitary structure of Ukraine, strong administrative command and good communications between regions of the country are positive factors in favour of efficient implementation of the proposed plan. Deficiencies are associated with limited funding of this effort. (authors)

  7. The features of radiation induced lung fibrosis related with dosimetric parameters

    International Nuclear Information System (INIS)

    Oh, Young-Taek; Noh, O Kyu; Jang, Hyunsoo; Chun, Mison; Park, Kyung Joo; Park, Kwang Joo; Kim, Mi-Hwa; Park, Hae-Jin

    2012-01-01

    Background and purpose: Radiation induced lung fibrosis (RILF) is a major complication after lung irradiation and is very important for long term quality of life and could result in fatal respiratory insufficiency. However, there has been little information on dosimetric parameters for radiotherapy planning in the aspect of RILF. The features of RILF related with dosimetric parameters were evaluated. Methods and materials: Forty-eight patients with non-small cell lung carcinoma who underwent post-operative radiation therapy (PORT) without adjuvant chemotherapy were analyzed. The degree of lung fibrosis was estimated by fibrosis volume and the dosimetric parameters were calculated from the plan of 3-dimensional conformal radiotherapy. Results: The fibrosis volume and V-dose as dosimetric parameters showed significant correlation and the correlation coefficient ranged from 0.602 to 0.683 (P < 0.01). The degree of the correlation line was steeper as the dose increase and threshold dose was not found. Mean lung dose (MLD) showed strong correlation with fibrosis volume (correlation coefficient = 0.726, P < 0.01). Conclusions: The fibrosis volume is continuously increased with V-dose as the reference dose increases. MLD is useful as a single parameter for comparing rival plans in the aspect of RILF.

  8. Dosimetric response evaluation of tooth enamel for accelerator-based neutron radiation

    International Nuclear Information System (INIS)

    Khan, R.F.H.; Rink, W.J.; Boreham, D.R.

    2003-01-01

    To study the neutron response of human tooth enamel, a number of experiments with an accelerator-based neutron source have been designed. The neutron beam was produced with the low gamma yield, 7 Li(p,n) 7 Be type thick target, using the 3 MV McMaster K.N. Van de Graaff accelerator. The dosimetry was done using a pre-calibrated snoopy type neutron dosimeter. Neutron irradiation induces a dosimetric signal in the tooth enamel at the same defect site as gamma produced damage with the same g-values (g parallel =1.9973, width 0.4 mT g perpendicular =2.002, width 0.3 mT). The dosimetric signal grows linearly with neutron dose from 6-35 Gy tissue dose. Dosimetric response in two different grain sizes (300-500 μm, and grains <4 mm) has shown increased dosimetric amplitude in the larger grains. Dose build up effect on tooth inside the mouth due to cheek was simulated by placing a 4 mm thick paraffin wax layer between the beam and tooth, but had little effect. These results show that for mean neutron energy of 280 keV, the relative neutron response of the human tooth enamel ranges from 8% to 12% of the equivalent gamma ray response

  9. Dosimetric assessment of swallowing examinations with videofluoroscopy

    International Nuclear Information System (INIS)

    Costa, M.M.B.; Canevaro, L.V.; Azevedo, A.C.P.

    2001-01-01

    Dosimetric analysis measurements of the Dose-Area-Product (DAP) of 7 individuals were estimated for the deglutition dynamic using the videofluoroscopic method. The aim of this study is to establish in a preliminary way, typical DAP values for this kind of study. The DAP values were obtained attaching to the X ray tube exit, an ionization chamber from PTW and a Diamentor M4 meter. The typical DAP values obtained during the videofluoroscopic evaluation of the deglutition dynamic, including its three phases, was: 4101 ± 881 cGy.cm 2 and the typical DAP rate was 577 ± 94 cGy.cm 2 /min. These values refer to a standard patient (1.57 cm height, 56 kg. weight) and a protocol that can be performed in about 7 minutes. The values, defined herein as typical refer to the used protocol. To our knowledge, the mean DAP rate is a good parameter to estimate radiation exposure from videofluoroscopic study of swallowing process. (author)

  10. Contura Multi-Lumen Balloon Breast Brachytherapy Catheter: Comparative Dosimetric Findings of a Phase 4 Trial

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Douglas W., E-mail: darthur@mcvh-vcu.edu [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Vicini, Frank A. [Michigan Healthcare Professionals/21st Century Oncology, Farmington Hills, Michigan (United States); Todor, Dorin A. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States); Julian, Thomas B. [Allegheny General Hospital, Temple University School of Medicine, Pittsburgh, Pennsylvania (United States); Cuttino, Laurie W.; Mukhopadhyay, Nitai D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia (United States)

    2013-06-01

    Purpose: Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Methods and Materials: Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥95% of the prescribed dose (PD) covering ≥95% of the target volume (TV); maximum skin dose ≤125% of the PD; maximum rib dose ≤145% of the PD; and V150 ≤50 cc and V200 ≤10 cc. Results: Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Conclusions: Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals.

  11. Contura Multi-Lumen Balloon breast brachytherapy catheter: comparative dosimetric findings of a phase 4 trial.

    Science.gov (United States)

    Arthur, Douglas W; Vicini, Frank A; Todor, Dorin A; Julian, Thomas B; Cuttino, Laurie W; Mukhopadhyay, Nitai D

    2013-06-01

    Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥ 95% of the prescribed dose (PD) covering ≥ 95% of the target volume (TV); maximum skin dose ≤ 125% of the PD; maximum rib dose ≤ 145% of the PD; and V150 ≤50 cc and V200 ≤ 10 cc. Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P ≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals. Copyright © 2013 Elsevier Inc. All rights

  12. Comparison of dosimetric methods for virtual wedge analysis

    International Nuclear Information System (INIS)

    Bailey, M.; Nelson, V.; Collins, O.; West, M.; Holloway, L.; Rajapaske, S.; Arts, J.; Varas, J.; Cho, G.; Hill, R.

    2004-01-01

    Virtual Wedge is difficult even with the range of dosimetric methods available. Film dosimetry has the highest available resolution but require the development of film and analysis. The CA24 requires a water phantom setup, which is time consuming, and the accuracy (step size) and time are inversely proportional. The Profiler is much more simple to setup and provides a real time analysis that can prove useful for tuning beam characteristics. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  13. Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Mark [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel (Germany); Tuen Mun Hospital, Hong Kong (China); Grehn, Melanie [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Lübeck (Germany); Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Cremers, Florian [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Lübeck (Germany); Siebert, Frank-Andre [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel (Germany); Wurster, Stefan [Saphir Radiosurgery Center Northern Germany, Güstrow (Germany); Department for Radiation Oncology, University Medicine Greifswald, Greifswald (Germany); Huttenlocher, Stefan [Saphir Radiosurgery Center Northern Germany, Güstrow (Germany); Dunst, Jürgen [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel (Germany); Department for Radiation Oncology, University Clinic Copenhagen, Copenhagen (Denmark); Hildebrandt, Guido [Department for Radiation Oncology, University Medicine Rostock, Rostock (Germany); Schweikard, Achim [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Rades, Dirk [Department for Radiation Oncology, University Medical Center Schleswig-Holstein, Lübeck (Germany); Ernst, Floris [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); and others

    2017-03-15

    Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

  14. Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

    International Nuclear Information System (INIS)

    Chan, Mark; Grehn, Melanie; Cremers, Florian; Siebert, Frank-Andre; Wurster, Stefan; Huttenlocher, Stefan; Dunst, Jürgen; Hildebrandt, Guido; Schweikard, Achim; Rades, Dirk; Ernst, Floris

    2017-01-01

    Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

  15. Researches, development and characterization of dosimetric materials for monitoring in irradiation processes with high doses

    International Nuclear Information System (INIS)

    Galante, Ana Maria Sisti

    2003-01-01

    Dosimetric materials that can be produced in Brazil with material acquired in the national market to replace the imported dosimeters used in radiation processing were developed in this work. Mixtures of potassium nitrate and sensitizers compounds as manganese dioxide, barium nitrate and potassium bromide were prepared in the pellet form. Dosimetric characteristics such as dose-response useful range, sensitivity, environmental conditions and dose rate influences were evaluated in 60 Co gamma radiation fields. Dyed polymethylmethacrylate detectors were also produced and its dosimetric characteristics were evaluated. The main characteristics evaluated in this case were: dose response useful range sensitivity, environmental conditions, dose rate influences and radiation energy dependence in gamma radiation fields and accelerated electrons beam of 0.8 to 1.5 MeV. The applied analytic technique was spectrophotometry. The calibration was performed in the irradiation facilities belonging to IPEN and certified by the International Atomic Energy Agency by means of the program IDAS (International Dose Assurance Service ) using the Fricke dosimeter. The mixture of potassium nitrate and manganese dioxide presented the best results and a wide dose range between 200 and 600 kGy. The response of the developed polymethylmethacrylate detectors are similar to the imported detectors and the dose range is characteristic to each detector and depends on the dye added in its formulation. (author)

  16. Dosimetric quantities and basic data for the evaluation of generalised derived limits

    International Nuclear Information System (INIS)

    Harrison, N.T.; Simmonds, J.R.

    1980-12-01

    The procedures, dosimetric quantities and basic data to be used for the evaluation of Generalised Derived Limits (GDLs) in environmental materials and of Generalised Derived Limits for discharges to atmosphere are described. The dosimetric considerations and the appropriate intake rates for both children and adults are discussed. In most situations in the nuclear industry and in those institutions, hospitals and laboratories which use relatively small quantities of radioactive material, the Generalised Derived Limits provide convenient reference levels against which the results of environmental monitoring can be compared, and atmospheric discharges can be assessed. They are intended for application when the environmental contamination or discharge to atmosphere is less than about 5% of the Generalised Derived Limit; above this level, it will usually be necessary to undertake a more detailed site-specific assessment. (author)

  17. Dosimetric methodology of the ICRP

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    1994-01-01

    Establishment of guidance for the protection of workers and members of the public from radiation exposures necessitates estimation of the radiation dose to tissues of the body at risk. The dosimetric methodology formulated by the International Commission on Radiological Protection (ICRP) is intended to be responsive to this need. While developed for radiation protection, elements of the methodology are often applied in addressing other radiation issues; e.g., risk assessment. This chapter provides an overview of the methodology, discusses its recent extension to age-dependent considerations, and illustrates specific aspects of the methodology through a number of numerical examples

  18. Dosimetric monitoring in Ukraine - present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2005-01-01

    Full text: Ukraine is the country which utilizes radiation in many peaceful areas. So, nuclear energy sector includes 15 power units (including two new units commissioned in 2004), nuclear fuel cycle also include uranium mines, radiation sources are widely used in industry, science and medicine. As a result, about 50,000 occupationally exposed workers require dosimetric monitoring. However, presently dosimetry services in Ukraine cover only about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca. 12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services, responsible for dosimetric monitoring in industry and medicine operate in 13 of 25 oblasts (regions) of Ukraine. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38 % to 100 % depending on the oblast. With rare exception, instrumentation is represented by outdated manual TLD systems (inaccurate and insufficiently sensitive) capable of measurement of deep photon dose only; no personal monitoring of beta and neutron exposure is possible now. Quality assurance is limited to the annual metrological attestation of the dosimetric instruments. No information exchange infrastructure and dosimetric registry are in place. The dosimetric data is stored in home-made data environments or even in paper log-books, no data on individual doses is conveyed to central depository, which could be easily accessible for regulating authorities. Although the standing law requires elaboration of the United System for monitoring and registration individual doses, little was done so far, mainly due to lack of domestic funding. However, intention is strong to build such network in accordance with the best practice, covering not only the aspects of physical measurement and data storage, but also quality assurance, accreditation programs and training of the local personnel

  19. Management and processing of dosimetric data of workers exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Rasoarimalala, T.

    2012-01-01

    The Madagascar - INSTN Radiation protection and Dosimetry Department use the reader HARSHAW TLD 6600 for workers doses reading. Although the performance of this device, manual works is required to store and to maintain the dosimetric data after reading and to note the TLDs sent to the establishments. To avoid these manual works, this present work proposes computer programs written in Python and using SQLite software. One of the programs in python retrieves dose values after reading and transfers directly these doses in the workers database. The use of SQLite software provides a way for the dosimetric data management and the TLDs movement monitoring. The other program assesses estimation of the dose received by worker through a trend curve for workers dosimetric monitoring. The calculated differences of this curve over the curve connecting all points are less than 20%, acceptable limit in radiation protection for TLDs. This present work presents then significances for the personnel occupying individual monitoring of ionizing radiation workers and for these workers too. [fr

  20. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    International Nuclear Information System (INIS)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing

    2014-01-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V 100% ), max PTV dose (PTV D max ), percentage prescription dose to 0.35 cc of cord (cord D 0.35 cc ), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D 0.35 cc and D 5 cc ), and volume of the lungs receiving at least 20 Gy (lung V 20 ). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were 100% , PTV D max , cord D 0.35 cc , esophagus D 0.35 cc , esophagus D 5 cc , and lung V 20 was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R 2 range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets

  1. Dosimetric optimization of worksite involving the installation of VATS containing highly active effluent

    International Nuclear Information System (INIS)

    Legee, F.; Busani, J.; Madigand, Y.; Pailloux, J.

    1996-01-01

    Within the framework of safety improvements at the CEA, CEA-FAR, concerned to formalize the ALARA initiative, has carried out for information and training purpose and to create awareness a dosimetric assessment of the worksite where new storage vats for highly active effluents are to be installed. The approach used for this worksite is global. Techniques used were all complementary, ensuring constant elaboration, experiment follow-up and feedback of a worksite at a relatively low dosimetric cost (an estimated 36 men.mSv brought down to 30 men.mSv through implementation of the ALARA principle). This type of global conception of radioprotection involving all the employees (head of project, project managers, companies, radioprotection employees...) which today proves its worth on a modest worksite must now be extended to worksites of a broader scope (several hundreds of men.mSv) where fulfillment of the dosimetric objectives is a major stake. (author)

  2. Dosimetric essay in dental radiology

    International Nuclear Information System (INIS)

    Lopez Salaberry, M.

    1998-01-01

    A neck study was observated in the tiroids glands,laryngeal zone, sensitive organs for the ionizing radiation for increase dental xray exams. Was selected 29th patients with radiography prescription complete (in the Odontology Faculty Clinics Uruguaian). It took radiographies with and without tiroids necklace and apron lead using dosemeters. Dosimetric studies had demonstrated good dose between patients. For measuring the radiation dose have been used TLD thermoluminescence dosimetric and Harshaw 6600 for read it. The thyroids necklace use and odontology postgrading for training course for dentistry was the two recommendations advised

  3. The dosimetric control in radiotherapy

    International Nuclear Information System (INIS)

    Veres, A.

    2009-01-01

    The author first presents the thermoluminescent dosimetry method developed by the Equal-Estro Laboratory to control radiotherapy systems, according to which dosimeters are mailed by the radiotherapy centres to the laboratory, and then analyzed with respect to the level of dose bias. In a second part, he discusses the different techniques used for the dosimetric control of new radiotherapy methods (intensity-modulated radiation therapy, tomo-therapy) for which film dosimetry is applied. He also evokes the development of new phantoms and the development of a method for the dosimetric control of proton beams

  4. Dosimetric verification for radiotherapy quality audit under reference and non-reference conditions in Jiangsu province

    International Nuclear Information System (INIS)

    Wang Jin; Yu Ningle; Yang Chunyong; Du Xiang; Chen Wei; Luo Suming

    2014-01-01

    Objective: To verify the methodology for auditing dosimetric parameters in reference and non-reference conditions with thermoluminescent dosimeters (TLDs). Methods: Under reference and non-reference conditions, the established TLD methods were used to observe the absorbed dose variations with depth, SSD, field size and 45 wedges for 10 photon beams at 5 hospitals. Dosimetric parameters, including doses at D_m_a_x points in axis, on 5 electron beams of 9 MeV were measured. The measurement results were compared between the TLDs and plane parallel ionization chambers. Results: For 6 MV photon beams, the relative deviation of between finger ionization chamber method and TLD chips was in the range of -1.7% to 5.4% under on-axis non-reference conditions, and -6.3% to -0.6% under off-axis non-reference conditions, respectively, all within the range of ≤ ±7% as required by the IAEA. The relative deviation between plane parallel chamber and TLD method was -2.3% to 3.7%, within ±5% as required by the IAEA. Conclusions: It is convenient and feasible to use TLD method for quality audits of dosimetric parameters in radiotherapy. (authors)

  5. Energy absorption buildup factors for thermoluminescent dosimetric materials and their tissue equivalence

    DEFF Research Database (Denmark)

    Manohara, S.R.; Hanagodimath, S.M.; Gerward, Leif

    2010-01-01

    Gamma ray energy-absorption buildup factors were computed using the five-parameter geometric progression (G-P) fitting formula for seven thermoluminescent dosimetric (TLD) materials in the energy range 0.015-15 MeV, and for penetration depths up to 40 mfp (mean free path). The generated energy-absorption...

  6. RPL-SC dosimetric system for measuring gamma and neutron irradiation in case of emergency

    International Nuclear Information System (INIS)

    Khristova, M. G.

    1993-01-01

    A RPL-SC dosimetric system is designed based on radiophotoluminescence (RPL) and on the effect of fast neutron bombardment of silicon semiconductor (SC) diodes. The experimental prototype consists of a computerized automatic measurement system and an individual dosimetric cassette accommodating RPL and SC detectors. The equipment includes: a device for measurement of the direct voltage of Si diodes and the RPL light emitted by RPL detectors; a compartment with dosimetric cassettes to be measured; a manipulator with three positions executing automatic measurement of cassettes; a computer and a printer. The system operates in both manual and automatic modes. In the manual mode each step of the manipulator is set up by the operator who changes the ranges after they have been filled to capacity and registers the results. In the automatic mode the whole process of maintaining the supply and control voltage, of manipulator's operation, measuring, data recording and data processing are controlled by a specially designed computer programme. Main technical parameters: 1) Measurement range of absorbed dose: gamma rays - 10 -3 to 10 2 Gy; thermal neutrons - 10 -3 to 10 2 Gy; fast neutrons - 10 to 30 Gy. 2) Energy range: gamma rays - 0.04 to 1.25 MeV; thermal neutrons - 0.024 eV; fast neutrons - 0.3 to 14 MeV. 3) Relative measurement error - ±15% 4) Recurrent measurement of one and the same dose. 5) Measurement time of 1 detector - 15 sec. (author)

  7. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yun; Catalano, Suzanne; Kelsey, Chris R.; Yoo, David S.; Yin, Fang-Fang; Cai, Jing, E-mail: jing.cai@duke.edu

    2014-04-01

    To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V{sub 100%}), max PTV dose (PTV D{sub max}), percentage prescription dose to 0.35 cc of cord (cord D{sub 0.35} {sub cc}), percentage prescription dose to 0.35 cc and 5 cc of esophagus (esophagus D{sub 0.35} {sub cc} and D{sub 5} {sub cc}), and volume of the lungs receiving at least 20 Gy (lung V{sub 20}). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were < 1% or < 1 Gy. Of all rotational offsets, largest change in PTV V{sub 100%}, PTV D{sub max}, cord D{sub 0.35} {sub cc}, esophagus D{sub 0.35} {sub cc}, esophagus D{sub 5} {sub cc}, and lung V{sub 20} was − 8.36%, − 6.06%, 11.96%, 8.66%, 6.02%, and − 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R{sup 2} range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets.

  8. Applications of sensitivity function to dosimetric data adjustments

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu

    1984-01-01

    Sensitivity functions are applied to the dosimetric field in the spectrum unfolding technique, also called as the data adjustment technique which are statistical estimation procedures of the neutron spectrum or relating dosimetric quantities basing on the reaction-rate data measurements. Using the practical formulae and numerical examples of the sensitivity functions in the dosimetric data adjustments, two comments are made that (1) present sensitivity values are highly depending on the initial spectrum inputs and (2) more attention should be paid to the dependency of the sensitivity on the very uncertain covariance data inputs of the initial neutron spectrum. (author)

  9. Experiences of a secondary laboratory of dosimetric calibration from the radiation protection and hygiene center CPHR in its first year of work and the procedures for quality assessment used in the calibration and quality control service

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.; Jova Sed, L.

    1996-01-01

    Experiences of a secondary laboratory of dosimetric calibration from the Radiation Protection and Hygiene Center (CPHR) in first year of work and the procedures for quality assessment used in the calibration and quality control service of radiotherapeutic equipment. For the yield calibration of the calibrated sources an ionometric method was used using ionizing chambers coupled to electrometers. Those determination were based on dosimetric American Association of Physicists in Medicine (AAPM)

  10. Critical assessment of the deposition based dosimetric technique for radon/thoron decay products

    International Nuclear Information System (INIS)

    Mayya, Y.S.

    2010-01-01

    Inhalation doses due to radon ( 222 Rn) and thoron ( 220 Rn) are predominantly contributed by their decay products and not due to the gases themselves. Decay product measurements are being carried out essentially by either short-term active measurement like by air-sampling on a substrate followed by alpha or beta counting or by continuous active monitoring techniques based on silicon barrier detector. However, due to non-availability of satisfactory passive measurement techniques for the progeny species, it has been a usual practice to estimate the long time averaged progeny concentration from measured gas concentration using an assumed equilibrium factor. To be accurate, one is required to measure the equilibrium factor in situ along with the gas concentration. This being not practical, the assigned equilibrium factor (0.4 for indoor and 0.8 for outdoor for 222 Rn) approach has been an inevitable, though uncertain, part of the dosimetric strategies in both occupational and public domains. Further, in the case of thoron decay products however, equilibrium factor is of far more questionable validity. Thus, there is a need to shift from gas based dosimetric paradigm to that based on direct detection of progeny species

  11. Dosimetric investigations in mammography

    International Nuclear Information System (INIS)

    Metges, P.J.; Lorrain, S.

    1981-01-01

    The development film-screen detectors in radiological equipment has led us to study how to improve standard mammographic pictures (focus 0.3 x 0.3 mm, focus-film distance: 65) of thick and dense breasts by the use of an anti-scatter grid and by magnification. A dosimetric study was necessary to assess the doses delivered during mammographic examinations carried out according to various procedures. The results led to modify breast examination procedures and use an anti-scatter grid for breasts thicker than 4 cm or known as dense. The dose increase due to a better quality image is the lowest provided depth penetration is increased by 2 kV as compared to a standard picture. Absorbed doses on the X-ray axis, at 3 cm depth, are below 0.1 rad [fr

  12. Evolution of dosimetric phantoms

    International Nuclear Information System (INIS)

    Reddy, A.R.

    2010-01-01

    In this oration evolution of the dosimetric phantoms for radiation protection and for medical use is briefly reviewed. Some details of the development of Indian Reference Phantom for internal dose estimation are also presented

  13. Ten years of a National Service of Dosimetric calibration at radiation protection

    International Nuclear Information System (INIS)

    Morales, J.A.; Jova, L.; Hernandez, E.; Campa, R.; Walwyn, G.

    1996-01-01

    Since 1986, the CPHR has offered a national service of calibration of dosimetric instruments at levels of radiation protection. The history of such a service is the chronology of efforts to reduce the uncertainties of the calibration process, expand the ranges of useful dose rates, and enhance the radiological safety when using the sources. The crowning of those efforts is the complement and start-up of the secondary la laboratory of dosimetric calibration (SLDC), which is currently a member of the IAEA/WHO. SLDC international network. As a result of this service, 256 instruments have been calibration and 867 personal dosimeters film badges and TLD and 72 environmental TLD dosimeters have been irradiated at known doses. The service rendered has benefited 62 national institutions which are users of ionizing radiations

  14. SU-F-T-19: The Consistency Dosimetric Analysis of the Accelerated Breast Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pinder, J; Chandrasekara, S; Pella, S [21st Century Oncology, Boca Raton, FL (United States)

    2016-06-15

    Purpose: To assess the best approach in accept a treatment plan for APBI Savi patients. Should we run a treatment verification test prior to delivering it to the patient? Should we check each CT scan in regards to the initial one in dosimetrical terms? Do we need deformable registration and adaptive planning for each fraction? These are the questions we want to answer running a dosimetric analysis of the dose variances for APBI treatments who receive 10 fractions and no re-planning has been done being considered unnecessary with today’s means of assessment. Methods: A retrospective analysis of 30 patients treated with SAVI applicators were considered for this study. The CT scans taken before each treatment were imported in the treatment planning system and registered with the initial CT scan. The images were fused together with respective to the applicator, using landmark registration. Dosimetric evaluations were performed. Dose received by skin, ribs and PTV on CT images with respect to the initial treatment plan were recorded including maximum, average and minimum dose Results: All the structures displayed changes in volume over the 10 fractions of treatment. The cavities reduction in volume was considerable with a maximum reduction of over 10%. The PTV-eval is covered better due to this fact while the critical organs manifest an increase in the total and maximum dose delivered. Ribs and skin surface that are required by B39 protocol to be monitored can acquire maximum doses of 20% to 30% respectively. Conclusion: A dosimetric evaluation prior to the initial treatment and prior to each of the 10 fractions is proven to be necessary. Deformable registration and adaptive planning have to be studied more and eventually implemented for every patient who received more than one fraction of any type of brachytherapy treatment. Immobilization ad localization methods must be improved and studied further.

  15. Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry in carbon-ion radiotherapy

    International Nuclear Information System (INIS)

    Kanematsu, Nobuyuki; Koba, Yusuke; Ogata, Risa

    2013-01-01

    Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid phantoms are often used for convenience. These materials should ideally be equivalent to water. In this study, the authors evaluated dosimetric water equivalence of four common plastics, high-density polyethylene (HDPE), polymethyl methacrylate (PMMA), polyethylene terephthalate (PET), and polyoxymethylene (POM). Methods: Using the Bethe formula for energy loss, the Gottschalk formula for multiple scattering, and the Sihver formula for nuclear interactions, the authors calculated the effective densities of the plastics for these interactions. The authors experimentally measured variation of the Bragg peak of carbon-ion beams by insertion of HDPE, PMMA, and POM, which were compared with analytical model calculations. Results: The theoretical calculation resulted in slightly reduced multiple scattering and severely increased nuclear interactions for HDPE, compared to water and the other plastics. The increase in attenuation of carbon ions for 20-cm range shift was experimentally measured to be 8.9% for HDPE, 2.5% for PMMA, and 0.0% for POM while PET was theoretically estimated to be in between PMMA and POM. The agreement between the measurements and the calculations was about 1% or better. Conclusions: For carbon-ion beams, POM was dosimetrically indistinguishable from water and the best of the plastics examined in this study. The poorest was HDPE, which would reduce the Bragg peak by 0.45% per cm range shift, although with marginal superiority for reduced multiple scattering. Between the two clear plastics, PET would be superior to PMMA in dosimetric water equivalence.

  16. Hot pixel generation in active pixel sensors: dosimetric and micro-dosimetric response

    Science.gov (United States)

    Scheick, Leif; Novak, Frank

    2003-01-01

    The dosimetric response of an active pixel sensor is analyzed. heavy ions are seen to damage the pixel in much the same way as gamma radiation. The probability of a hot pixel is seen to exhibit behavior that is not typical with other microdose effects.

  17. Using measurable dosimetric quantities to characterize the inter-structural tradeoff in inverse planning

    Science.gov (United States)

    Liu, Hongcheng; Dong, Peng; Xing, Lei

    2017-08-01

    Traditional inverse planning relies on the use of weighting factors to balance the conflicting requirements of different structures. Manual trial-and-error determination of weighting factors has long been recognized as a time-consuming part of treatment planning. The purpose of this work is to develop an inverse planning framework that parameterizes the dosimetric tradeoff among the structures with physically meaningful quantities to simplify the search for clinically sensible plans. In this formalism, instead of using weighting factors, the permissible variation range of the prescription dose or dose volume histogram (DVH) of the involved structures are used to characterize the ‘importance’ of the structures. The inverse planning is then formulated into a convex feasibility problem, called the dosimetric variation-controlled model (DVCM), whose goal is to generate plans with dosimetric or DVH variations of the structures consistent with the pre-specified values. For simplicity, the dosimetric variation range for a structure is extracted from a library of previous cases which possess similar anatomy and prescription. A two-phase procedure (TPP) is designed to solve the model. The first phase identifies a physically feasible plan to satisfy the prescribed dosimetric variation, and the second phase automatically improves the plan in case there is room for further improvement. The proposed technique is applied to plan two prostate cases and two head-and-neck cases and the results are compared with those obtained using a conventional CVaR approach and with a moment-based optimization scheme. Our results show that the strategy is able to generate clinically sensible plans with little trial and error. In all cases, the TPP generates a very competitive plan as compared to those obtained using the alternative approaches. Particularly, in the planning of one of the head-and-neck cases, the TPP leads to a non-trivial improvement in the resultant dose distribution

  18. Basic principles and practices of integrated dosimetric passportization of the settlements in Ukraine

    International Nuclear Information System (INIS)

    Lyikhtar'ov, Yi.A.; Kovgan, L.M.; Masyuk, S.V.; Yivanova, O.M.; Chepurnij, M.Yi.; Bojko, Z. N.; Gerasimenko, V.B.

    2015-01-01

    The objective of the review is to demonstrate the results of dosimetric passportization (performed in 1991- 2014) for the settlements of Ukraine which suffered from radioactive contamination caused by the Chornobyl accident. The dosimetric passportization played a key role in the National program on the liquidation of after- math of the Chornobyl accident through all stages of the current radiation situation control and decision support touching upon various types of interventions and social benefits to the population of radioactively contaminated areas. The works being performed under dosimetric passportization did not have analogues among the researches which took place after other large-scale industrial and municipal accidents as well their scales as the duration of both radio-ecological and dosimetric monitoring. The new methodological approaches to the assessment of so-called passport doses of a settlement as well as to the definition of the concept of annual dose being the dose used to make decisions for providing both direct and indirect emergency countermeasures for the settlements of Ukraine became pioneering ones. During all the post-accident period there were issued sixteen collections of general dosimetric passportization data which accumulate the results of hundreds of thousands spectrometric, radiochemical and radiation levels measurements and WBC measurements carried out in 1991-2014. The annual passport doses calculated on the basis of these measurements (including their components) are unique information that quantifies the level and time dynamics of the radiation situation for each of the 2161 settlements of 74 districts in 12 regions during all the post-accident period. Thanks to the works of dosimetric passportization of the settlements of Ukraine there were created databases to be unique in their structure and content with quantitative characteristics of the territorial and temporal distribution, the dynamics of changes of a number of important

  19. CT and MR image fusion using two different methods after prostate brachytherapy: impact on post-implant dosimetric assessment

    International Nuclear Information System (INIS)

    Servois, V.; El Khoury, C.; Lantoine, A.; Ollivier, L.; Neuenschwander, S.; Chauveinc, L.; Cosset, J.M.; Flam, T.; Rosenwald, J.C.

    2003-01-01

    To study different methods of CT and MR images fusion in patient treated by brachytherapy for localized prostate cancer. To compare the results of the dosimetric study realized on CT slices and images fusion. Fourteen cases of patients treated by 1125 were retrospectively studied. The CT examinations were realized with continuous section of 5 mm thickness, and MR images were obtained with a surface coil with contiguous section of 3 mm thickness. For the images fusion process, only the T2 weighted MR sequence was used. Two processes of images fusion were realized for each patient, using as reference marks the bones of the pelvis and the implanted seeds. A quantitative and qualitative appreciation was made by the operators, for each patient and both methods of images fusion. The dosimetric study obtained by a dedicated software was realized on CT images and all types of images fusion. The usual dosimetric indexes (D90, V 100 and V 150) were compared for each type of image. The quantitative results given by the software of images fusion showed a superior accuracy to the one obtained by the pelvic bony reference marks. Conversely, qualitative and quantitative results obtained by the operators showed a better accuracy of the images fusion based on iodine seeds. For two patients out of three presenting a D90 inferior to 145 Gy on CT examination, the D90 was superior to this norm when the dosimetry was based on images fusion, whatever the method used. The images fusion method based on implanted seed matching seems to be more precise than the one using bony reference marks. The dosimetric study realized on images fusion could allow to rectify possible errors, mainly due to difficulties in surrounding prostate contour delimitation on CT images. (authors)

  20. Biologic data, models, and dosimetric methods for internal emitters

    International Nuclear Information System (INIS)

    Weber, D.A.

    1990-01-01

    The absorbed radiation dose from internal emitters has been and will remain a pivotal factor in assessing risk and therapeutic utility in selecting radiopharmaceuticals for diagnosis and treatment. Although direct measurements of absorbed dose and dose distributions in vivo have been and will continue to be made in limited situations, the measurement of the biodistribution and clearance of radiopharmaceuticals in human subjects and the use of this data is likely to remain the primary means to approach the calculation and estimation of absorbed dose from internal emitters over the next decade. Since several approximations are used in these schema to calculate dose, attention must be given to inspecting and improving the application of this dosimetric method as better techniques are developed to assay body activity and as more experience is gained in applying these schema to calculating absorbed dose. Discussion of the need for considering small scale dosimetry to calculate absorbed dose at the cellular level will be presented in this paper. Other topics include dose estimates for internal emitters, biologic data mathematical models and dosimetric methods employed. 44 refs

  1. Dosimetric characteristics of Li2B4O7:Cu,Ag,P solid TL detectors

    International Nuclear Information System (INIS)

    Proki, M.

    2002-01-01

    The main dosimetric characteristics are presented of newly prepared tissue-equivalent, highly sensitive thermoluminescent detector, Li 2 B 4 O 7 :Cu,Ag,P in the form of sintered pellets, developed at the Institute of Nuclear Sciences, Vin a . As a result of an advancement in the preparation procedure by the sensitising of basic copper activated lithium borate TL material, significant improvement in the TL sensitivity of Li 2 B 4 O 7 :Cu,Ag,P was gained. The glow curve of Li 2 B 4 O 7 :Cu,Ag,P consists of well defined main dosimetric peak situated at about 185-190 deg. C with the TL sensitivity which is about four to five times higher than that of LiF:Mg,Ti (TLD-100). From the experimental results a very wide linear dose response range, up to 10 3 Gy is evident. Dosimetric characteristics make sintered solid Li 2 B 4 O 7 :Cu,Ag,P TL detectors very promising for different dosimetry applications particularly in medical dosimetry and also for individual monitoring. (author)

  2. Dosimetric Evaluation of Automatic Segmentation for Adaptive IMRT for Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Tsuji, Stuart Y.; Hwang, Andrew; Weinberg, Vivian; Yom, Sue S.; Quivey, Jeanne M.; Xia Ping

    2010-01-01

    Purpose: Adaptive planning to accommodate anatomic changes during treatment requires repeat segmentation. This study uses dosimetric endpoints to assess automatically deformed contours. Methods and Materials: Sixteen patients with head-and-neck cancer had adaptive plans because of anatomic change during radiotherapy. Contours from the initial planning computed tomography (CT) were deformed to the mid-treatment CT using an intensity-based free-form registration algorithm then compared with the manually drawn contours for the same CT using the Dice similarity coefficient and an overlap index. The automatic contours were used to create new adaptive plans. The original and automatic adaptive plans were compared based on dosimetric outcomes of the manual contours and on plan conformality. Results: Volumes from the manual and automatic segmentation were similar; only the gross tumor volume (GTV) was significantly different. Automatic plans achieved lower mean coverage for the GTV: V95: 98.6 ± 1.9% vs. 89.9 ± 10.1% (p = 0.004) and clinical target volume: V95: 98.4 ± 0.8% vs. 89.8 ± 6.2% (p 3 of the spinal cord 39.9 ± 3.7 Gy vs. 42.8 ± 5.4 Gy (p = 0.034), but no difference for the remaining structures. Conclusions: Automatic segmentation is not robust enough to substitute for physician-drawn volumes, particularly for the GTV. However, it generates normal structure contours of sufficient accuracy when assessed by dosimetric end points.

  3. Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.; Musijachenko, A.

    2004-01-01

    Development of the nation-wide network for monitoring and registration of individual doses is being in progress in Ukraine. The need for urgent action is caused by the fact, that despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralized dose accounting system in Ukraine, existing dosimetry services operate obsolete manual TLD readers and no methodological unity is observed by the dosimetry services. Presently the mixed dosimetric monitoring is practiced in Ukraine. Nuclear power plants and some major nuclear facilities have their own dosimetry services responsible for dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by territorial dosimetry laboratories affiliated to sanitary and epidemiology supervision bodies. In total these services cover about 38,000 occupationally exposed workers, including 5,500 in medicine, 16,400 employees of five nuclear power plants and about 16,000 workers dealing with other sources of occupational exposure (industry, research, military). It is prescribed by the governmental decree that three-level united state system assigned to covering all aspects of efficient dosimetric monitoring should be established. The tasks of the system, in particular, are: securing methodical unity of individual dosimetric monitoring; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programs; development and support of information infrastructure for logging, storage and access to data on individual dosimetric monitoring, in particular - keeping the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. In its development, the national system will be guided by international experience and will be established according to the best practices

  4. Computerized dosimetric system for studying radiation fields of afterloading apparatus

    International Nuclear Information System (INIS)

    Andryushin, O.S.; Gorshkov, M.I.

    1988-01-01

    Works on designing a computerized dosimetric scanner (CODOS) for studying radiation fields of remote therapeutic apparatus, providing dosimetric data input from semiconductor transducers and ionization chambers directly into the computer memory were carried out. The basic problems were to provide reproducibility and accuracy of the initial dosimetric data, formation of the data bank on LUEhV-15M1 accelerator bremsstrahlung and electron radiation fields. An extra problem was to provide isodose curves for manual scheduling of radiotherapy. The 15 VUMS-28-025 complex based on Elektronika-60 computer was chosen as a host computer, photodiodes were used as a semiconductor detector, the 70108 rod chamber and VA-J-18 dosemeters were used as an ionization chamber. The results of studies with the CODOS system have been shown that it meets the dosimetric requirements for therapeutic apparatus

  5. Dosimetric study to voxel model applied to cardiac exams in Nuclear medicine

    International Nuclear Information System (INIS)

    Cassola, V.F.; Silva, A.M. Marques da; Hoff, G.

    2008-01-01

    The objective of this study is to analyze the dosimetry in a simplified model of the region of interest of myocardial perfusion studies considering different descriptions of Tc-99m emission spectra. It aims to assess the implications of these different approaches in the description of Tc-99m spectrum, as well as their dosimetric implications

  6. SESAME: a software tool for the numerical dosimetric reconstruction of radiological accidents involving external sources and its application to the accident in Chile in December 2005.

    Science.gov (United States)

    Huet, C; Lemosquet, A; Clairand, I; Rioual, J B; Franck, D; de Carlan, L; Aubineau-Lanièce, I; Bottollier-Depois, J F

    2009-01-01

    Estimating the dose distribution in a victim's body is a relevant indicator in assessing biological damage from exposure in the event of a radiological accident caused by an external source. This dose distribution can be assessed by physical dosimetric reconstruction methods. Physical dosimetric reconstruction can be achieved using experimental or numerical techniques. This article presents the laboratory-developed SESAME--Simulation of External Source Accident with MEdical images--tool specific to dosimetric reconstruction of radiological accidents through numerical simulations which combine voxel geometry and the radiation-material interaction MCNP(X) Monte Carlo computer code. The experimental validation of the tool using a photon field and its application to a radiological accident in Chile in December 2005 are also described.

  7. SU-F-T-107: Correlations Between Dosimetric Indices of Pharyngeal Constrictors and Proximal Esophagus with Associated Patient-Reported Outcomes Six Months After Radiation Therapy for Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chera, B; Price, A; Kostich, M; Green, R; Das, S; Mavroidis, P [University of North Carolina, Chapel Hill, North Carolina (United States); Amdur, R; Mendenhall, W [University of Florida, Gainesville, FL (United States); Sheets, N [University of North Carolina, Raleigh, North Carolina (United States); Marks, L [UNC School of Medicine, Chapel Hill, NC (United States)

    2016-06-15

    Purpose: To compare the correlations between different dosimetric indices derived from the pharyngeal constrictor muscles and proximal esophagus with patient-reported difficulty in swallowing 6 months post radiotherapy using a novel patient reported outcome version of CTCAE (PRO-CTCAE). Methods: Forty-three patients with oropharyngeal squamous cell carcinoma were treated on a prospective multi-institutional study. All patients received de-intensified 60 Gy intensity modulated radiotherapy. We investigated correlations of individual patient dosimetric data of the superior (SPC), middle (MPC), inferior (IPC) pharyngeal constrictor muscles, the superior esophagus (SES), and the inferior esophagus (IES) to their self-reported 6 month post-treatment swallowing difficulty responses. Mild (≥ Grade 1) swallowing difficulty responses were used as the clinical endpoint indicating response. The predictive efficacy of Dmean and dose-volume (VD) points were assessed through the area under the Receiver Operating Characteristic curve (ROC) and Odds Ratio (OR). Results: The SES and SPC had more favorable area under the curves (AUC) for the Dmean (0.62 and 0.70) while the Dmean to the IPC, MPC, and IES produced suboptimal AUCs (0.42, 0.48, and 0.52). Additionally, over the range of VD, the V54 and V55 for the SES and SPC demonstrated the highest AUCs: AUC(SES) = 0.76–0.73 and AUC(SPC) = 0.72–0.69, respectively. The IES, IPC, and MPC had worse AUC results over the range of VD. An optimal OR can be found when V54 = 96% for the SPC, where OR = 3.96 (1.07–14.62). Conclusion: The V45 and V55 of the SES and SPC had the highest correlation to the clinical endpoint compared to the commonly used dosimetric index, Dmean for both the esophagus and constrictor muscles. The reported dosimetric data demonstrates that new dosimetric indices may need to be considered in the setting of dose de-escalation and self-reported outcomes.

  8. Basic Principles and Practices of Integrated Dosimetric Passportization of the Settlements in Ukraine.

    Science.gov (United States)

    Likhtarov, I A; Kovgan, L M; Masiuk, S V; Ivanova, O M; Chepurny, M I; Boyko, Z N; Gerasymenko, V B

    2015-12-01

    The purpose of the review is to demonstrate the results of dosimetric passportization (performed in 1991-2014) for the settlements of Ukraine which suffered from radioactive contamination caused by the Chornobyl accident. The dosimetric passportization played a key role in the National program on the liquidation of aftermath of the Chornobyl accident directed on recovery through all stages of the current radiation situation control and decision support touching upon various types of interventions and social benefits to the population of radioactively contaminated areas. The works being performed under dosimetric passportization did not have analogues among the researches which took place after other large-scale industrial and municipal accidents as well their scales as the duration of both radio-ecological and dosimetric monitoring.The new methodological approaches to the assessment of so-called passport doses of a settlement as well as to the definition of the concept of annual dose being the dose used to make decisions for providing both direct and indirect emergency countermeasures for the settlements of Ukraine became pioneering ones. During all the post-accident period there were issued sixteen collections of general dosimetric passportization data which accumulate the results of hundreds of thousands spectrometric, radiochemical and radiation levels measurements and WBC measurements carried out in 1991-2014.The annual passport doses calculated on the basis of these measurements (including their components) are unique information that quantifies the level and time dynamics of the radiation situation for each of the 2161 settlements of 74 raions in 12 oblasts during all the post-accident period. Thanks to the works of dosimetric passportization of the settlements of Ukraine there were created databases to be unique in their structure and content with quantitative characteristics of the territorial and temporal distribution, the dynamics of changes of a number

  9. Dosimetric characteristics of biological effect of sulfur-35

    International Nuclear Information System (INIS)

    Borisova, V.V.

    1990-01-01

    Experimental materials related to evaluation of dosimetric characteristics of sulfur-35 are presented. Hemogenic organs are subjected to greatest influence especially in the first hours after radionuclide entry into the organism. Comparison is made of absorbed doses in blood with observed blastomogen effect of hemogenic organs. It is noted, that quantitative evaluation of relative biological efficiency of low energy beta-emitters should be performed with account of dosimetric peculiarities of the nuclides mentioned above. 10 refs.; 3 tabs

  10. Discussion on concepts for radiological dosimetric quantities in the Japan Health Physics Society

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki; Oda, Keiji

    2007-01-01

    Many dosimetric quantities have been used for radiation protection purpose. The International Commission on Radiological Protection (ICRP) has recommended protection quantities and the International Commission on Radiation Units and Measurements (ICRU) has introduced operational quantities to provide a reasonable estimate of the protection quantities. Enthusiastic discussions are continuously made on the issues of the dosimetric quantities, such as basic biological data for the definition of these quantities and applicability of the quantities to actual radiation protection practice. At the moment, some changes are being proposed concerning dosimetric quantities in the draft recommendations of ICRP, opened for consultation in recent years. Thus, the Japan Health Physics Society (JHPS) established the Expert Committee on concepts of Dosimetric Quantities used in radiological protection (ECDQ) in April 2005 to reviewed and discuss issues in the dosimetric quantities. (author)

  11. Dosimetric management during a criticality accident

    International Nuclear Information System (INIS)

    Lebaron-Jacobs, L.; Fottorino, R.; Racine, Y.; Miele, A.; Barbry, F.; Briot, F.; Distinguin, S.; Le Goff, J.P.; Berard, P.; Boisson, P.; Cavadore, D.; Lecoix, G.; Persico, M.H.; Rongier, E.; Challeton-De Vathaire, C.; Medioni, R.; Voisin, P.; Exmelin, L.; Flury-Herard, A.; Gaillard-Lecanu, E.; Lemaire, G.; Gonin, M.; Riasse, C.

    2008-01-01

    A working group from health occupational and clinical biochemistry services on French sites has issued essential data sheets on the guidelines to follow in managing the victims of a criticality accident. Since the priority of the medical management after a criticality accident is to assess the dose and the distribution of dose, some dosimetric investigations have been selected in order to provide a prompt response and to anticipate the final dose reconstruction. Comparison exercises between clinical biochemistry laboratories on French sites were carried out to confirm that each laboratory maintained the required operational methods for hair treatment and the appropriate equipment for 32 P activity in hair and 24 Na activity in blood measurements, and to demonstrate its ability to rapidly provide neutron dose estimates after a criticality accident. As a result, a relation has been assessed to estimate the dose and the distribution of dose according to the neutron spectrum following a criticality accident. (authors)

  12. Online dosimetric evaluation of larynx SBRT: A pilot study to assess the necessity of adaptive replanning.

    Science.gov (United States)

    Mao, Weihua; Rozario, Timothy; Lu, Weiguo; Gu, Xuejun; Yan, Yulong; Jia, Xun; Sumer, Baran; Schwartz, David L

    2017-01-01

    We have initiated a multi-institutional phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for Stage III-IVa laryngeal cancer. We conducted this pilot dosimetric study to confirm potential utility of online adaptive replanning to preserve treatment quality. We evaluated ten cases: five patients enrolled onto the current trial and five patients enrolled onto a separate phase I SBRT trial for early-stage glottic larynx cancer. Baseline SBRT treatment plans were generated per protocol. Daily cone-beam CT (CBCT) or diagnostic CT images were acquired prior to each treatment fraction. Simulation CT images and target volumes were deformably registered to daily volumetric images, the original SBRT plan was copied to the deformed images and contours, delivered dose distributions were re-calculated on the deformed CT images. All of these were performed on a commercial treatment planning system. In-house software was developed to propagate the delivered dose distribution back to reference CT images using the deformation information exported from the treatment planning system. Dosimetric differences were evaluated via dose-volume histograms. We could evaluate dose within 10 minutes in all cases. Prescribed coverage to gross tumor volume (GTV) and clinical target volume (CTV) was uniformly preserved; however, intended prescription dose coverage of planning treatment volume (PTV) was lost in 53% of daily treatments (mean: 93.9%, range: 83.9-97.9%). Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. Although GTV and CTV SBRT dose coverage is preserved with in-room three-dimensional image guidance, PTV coverage can vary significantly from intended plans and dose to critical structures may exceed tolerances. Online adaptive treatment re-planning is potentially necessary and clinically applicable to fully preserve treatment

  13. Benchmarking Dosimetric Quality Assessment of Prostate Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Senthi, Sashendra; Gill, Suki S.; Haworth, Annette; Kron, Tomas; Cramb, Jim; Rolfo, Aldo; Thomas, Jessica; Duchesne, Gillian M.; Hamilton, Christopher H.; Joon, Daryl Lim; Bowden, Patrick; Foroudi, Farshad

    2012-01-01

    Purpose: To benchmark the dosimetric quality assessment of prostate intensity-modulated radiotherapy and determine whether the quality is influenced by disease or treatment factors. Patients and Methods: We retrospectively analyzed the data from 155 consecutive men treated radically for prostate cancer using intensity-modulated radiotherapy to 78 Gy between January 2007 and March 2009 across six radiotherapy treatment centers. The plan quality was determined by the measures of coverage, homogeneity, and conformity. Tumor coverage was measured using the planning target volume (PTV) receiving 95% and 100% of the prescribed dose (V 95% and V 100% , respectively) and the clinical target volume (CTV) receiving 95% and 100% of the prescribed dose. Homogeneity was measured using the sigma index of the PTV and CTV. Conformity was measured using the lesion coverage factor, healthy tissue conformity index, and the conformity number. Multivariate regression models were created to determine the relationship between these and T stage, risk status, androgen deprivation therapy use, treatment center, planning system, and treatment date. Results: The largest discriminatory measurements of coverage, homogeneity, and conformity were the PTV V 95% , PTV sigma index, and conformity number. The mean PTV V 95% was 92.5% (95% confidence interval, 91.3–93.7%). The mean PTV sigma index was 2.10 Gy (95% confidence interval, 1.90–2.20). The mean conformity number was 0.78 (95% confidence interval, 0.76–0.79). The treatment center independently influenced the coverage, homogeneity, and conformity (all p 95% only, with it being better at the start (p = .013). Risk status, T stage, and the use of androgen deprivation therapy did not influence any aspect of plan quality. Conclusion: Our study has benchmarked measures of coverage, homogeneity, and conformity for the treatment of prostate cancer using IMRT. The differences seen between centers and planning systems and the coverage

  14. Dosimetric and biological assessment in the Cuban program for children from areas affected by the Chernobyl accidents

    International Nuclear Information System (INIS)

    Garcia Lima, O.; Cruz, R.; Valdez, M.; Cardenas, J.; Jova, L.; Lopez, G.; Arado, O.; Lamadrid, A.I.; Morera, L.

    1996-01-01

    Since 1990 Cuba has been developing health care program to offer highly specialized medical assistance and to develop a rehabilitation program for children affected by the Chernobyl accident. as part of the program a group of dosimetric and biomedical studies have been performed tom asses the impact of the accident. The results obtained from the study with 4500 children streets the fact that external radiation was the most important contributor to the total dose, which was estimated between 1-170 mSv during 70 years, for an equal period of time the 137C s internal dose ranged between 1.5 and 565 Bq/Kg. The biomedical studies have been carried out in groups formed according to the surface contamination of the field and to the 137C s activity measured, The thyroid hyperplasia tend to increase with the increment of both parameters. The other analyzed factors did not show differences among the groups

  15. Dosimetric characterization of an a-based EPID for quality control if patient-specific IMRT

    International Nuclear Information System (INIS)

    Larrinaga Cortina, Eduardo Francisco; Alfonso Laguardia, Rodolfo; Silvestre Patallo, Ileana; Garcia Yip, Fernando

    2009-01-01

    The Electronic portal imaging devices, EPID for its acronym in English is a technology widely used for verification of patient positioning on linear accelerators routinely. Its use as a dosimetry device is not as widespread, although many researches in this field. It assessed the availability and versatility of the use EPID based on an amorphous silicon (a-Si) as a means of quality control specific patient for a methodology of Radiation Intensity Modulated IMRT. Dosimetric parameters were determined for the linearity of dose versus response, dispersion and sensitivity factors off-axis radiation. For absolute measurements the linearity of the dose-response relationship EPID was better than 1.1 and 1.5% for photon beams of 6 and 15mV respectively, in the range from 2 to 500 UM. The dose dependence with field size was studied and compared with the factors of dispersion in water at different depths, in agreement with those measured at 5 cm depth, Scp (z = 5cm). Off-axis sensitivity of the EPID was determined by comparing the measured profiles versus the same profiles at different depths in water. The best correspondence was observed at 5 cm depth, where the EPID response underestimates the dose to 4% for all sizes of fields in the plateau area. The EPID can be used for the evaluation of dosimetric parameters of the beam at a specific depth in water of 5 cm and a discrepancy in an acceptable maximum rate of 4%. (author)

  16. Radiation sensitivity and EPR dosimetric potential of gallic acid and its esters

    International Nuclear Information System (INIS)

    Tuner, Hasan; Oktay Bal, M.; Polat, Mustafa

    2015-01-01

    In the preset work the radiation sensitivities of Gallic Acid anhydrous and monohydrate, Octyl, Lauryl, and Ethyl Gallate (GA, GAm, OG, LG, and EG) were investigated in the intermediate (0.5–20 kGy) and low radiation (<10 Gy) dose range using Electron Paramagnetic Resonance (EPR) spectroscopy. While OG, LG, and EG are presented a singlet EPR spectra, their radiation sensitivity found to be very different in the intermediate dose range. At low radiation dose range (<10 Gy) only LG is found to be present a signal that easily distinguished from the noise signals. The intermediate and low dose range radiation sensitivities are compared using well known EPR dosimeter alanine. The radiation yields (G) of the interested material were found to be 1.34×10 −2 , 1.48×10 −2 , 4.14×10 −2 , and 6.03×10 −2 , 9.44×10 −2 for EG, GA, GAm, OG, and LG, respectively at the intermediate dose range. It is found that the simple EPR spectra and the noticeable EPR signal of LG make it a promising dosimetric material to be used below 10 Gy of radiation dose. - Highlights: • Radiation sensitivity of gallic acid and its esters were studied in intermediate and low radiation dose range using EPR. • While the irradiated samples of GA were presented complex EPR spectra the esters presented singlet ESR spectra. • Samples were compared to alanine in terms of the dosimetric point of view. • The radiation sensitivities of the investigated materials were very low at intermediate doses. • Lauryl ester of gallic acid was found to present a good sensitivity below 10 Gy

  17. SU-D-204-04: Correlations Between Dosimetric Indices and Follow-Up Data for Salivary Glands Six Months After Radiation Therapy for Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chera, B; Price, A; Kostich, M; Green, R; Das, S; Mavroidis, P [University of North Carolina, Chapel Hill, North Carolina (United States); Amdur, R; Mendenhall, W [University of Florida, Gainesville, FL (United States); Sheets, N [University of North Carolina, Raleigh, North Carolina (United States); Marks, L [UNC School of Medicine, Chapel Hill, NC (United States)

    2016-06-15

    Purpose: To investigate the correlation between different dosimetric indices of salivary glands (as separate or combined structures) to patient-reported dry mouth 6 months post radiotherapy using the novel patient reported outcome version of the CTCAE (PRO-CTCAE). Methods: Forty-three patients with oropharyngeal squamous cell carcinoma were treated on a prospective multi-institutional study. All patients received de-intensified 60 Gy intensity modulated radiotherapy. Dosimetric constraints were used for the salivary glands (e.g. mean dose to the contralateral-parotid < 26 Gy). We investigated correlations of individual patient dosimetric data of the parotid and submandibular glands (as separate or combined structures) to their self-reported 6 month post-treatment dry mouth responses. Moderate dry mouth responses were most prevalent and were used as the clinical endpoint indicating response. The correlation of Dmean, Dmax and a range of dosevolume (VD) points were assessed through the area under the Receiver Operating Characteristic curve (ROC) and Odds Ratios (OR). Results: Patients reporting non/mild dry mouth response (N=22) had average Dmean = 19.6 ± 6.2Gy to the contralateral-parotid compared to an average Dmean = 28.0 ± 8.3Gy and an AUC = 0.758 for the patients reporting moderate/severe/very severe dry mouth (N=21). Analysis of the range of VD’s for patients who had reported dry mouth showed that for the contralateral-parotid the indices V18 through V22 had the highest area under the curves (AUC) (0.762 – 0.772) compared to a more traditional dosimetric index V30, which had an AUC = 0.732. The highest AUC was observed for the combination of contralateral parotid and contralateral submandibular glands, for which V16 through V28 had AUC = 0.801 – 0.834. Conclusion: Patients who report moderate/severe/very severe dry mouth 6 months post radiotherapy had on average higher Dmean. The V16-V28 of the combination of the contralateral glands showed the highest

  18. Anatomic and dosimetric changes in patients with head and neck cancer treated with an integrated MRI-tri-60Co teletherapy device.

    Science.gov (United States)

    Raghavan, Govind; Kishan, Amar U; Cao, Minsong; Chen, Allen M

    2016-11-01

    Prior studies have relied on CT to assess alterations in anatomy among patients undergoing radiation for head and neck cancer. We sought to determine the feasibility of using MRI-based image-guided radiotherapy to quantify these changes and to ascertain their potential dosimetric implications. 6 patients with head and neck cancer were treated with intensity-modulated radiotherapy (IMRT) on a novel tri- 60 Co teletherapy system equipped with a 0.35-T MRI (VR, ViewRay Incorporated, Oakwood Village, OH) to 66-70 Gy in 33 fractions (fx). Pre-treatment MRIs on Fx 1, 5, 10, 15, 20, 25, 30 and 33 were imported into a contouring interface, where the primary gross tumour volume (GTV) and parotid glands were delineated. The centre of mass (COM) shifts for these structures were assessed relative to Day 1. Dosimetric data were co-registered with the MRIs, and doses to the GTV and parotid glands were assessed. Primary GTVs decreased significantly over the course of IMRT (median % volume loss, 38.7%; range, 29.5-72.0%; p < 0.05) at a median rate of 1.2%/fx (range, 0.92-2.2%/fx). Both the ipsilateral and contralateral parotid glands experienced significant volume loss (p < 0.05, for all) and shifted medially during IMRT. Weight loss correlated significantly with parotid gland volume loss and medial COM shift (p < 0.05). Integrated on-board MRI can be used to accurately contour and analyze primary GTVs and parotid glands over the course of IMRT. COM shifts and significant volume reductions were observed, confirming the results of prior CT-based exercises. Advances in knowledge: The superior resolution of on-board MRI may facilitate online adaptive replanning in the future.

  19. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    International Nuclear Information System (INIS)

    Fung, K.K.L.

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 μGy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  20. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.K.L

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 {mu}Gy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  1. Radiation process control, study and acceptance of dosimetric methods

    International Nuclear Information System (INIS)

    Radak, B.B.

    1984-01-01

    The methods of primary dosimetric standardization and the calibration of dosimetric monitors suitable for radiation process control were outlined in the form of a logical pattern in which they are in current use on industrial scale in Yugoslavia. The reliability of the process control of industrial sterilization of medical supplies for the last four years was discussed. The preparatory works for the intermittent use of electron beams in cable industry were described. (author)

  2. Computerized tomography in Community of Madrid. Reference dosimetric measurements

    International Nuclear Information System (INIS)

    Ruiz Sanz, S.; Calzado, A.; Melchor, M.; Marco, M.

    1994-01-01

    A total of about 43 computed tomography scanners were operating in the Autonomous Community of Madrid during 1991. A sample of 14 facilities was selected to perform dosimetric measurements in order to obtain characteristic dose profiles. From these, some quantities as the computed tomography dose index and the enhancement factor were calculated and analysed for the most common technique settings. Relations were established between the dosimetric results and technical characteristics of the scanners. (Author)

  3. Equine scintigraphy: assessment of the dose received by the personnel

    International Nuclear Information System (INIS)

    Clairand, I.; Bottollier, J.F.; Trompier, F.

    2003-01-01

    Following a request from the Permanent Secretary of the French Commission for Artificial Radioelements (CIREA) engaged to investigate a request for a licence related to a new scintigraphy unit dedicated to equidae, a dosimetric assessment concerning the personnel attending the examination was carried out. This scintigraphy unit depends on the Goustranville Centre for Imaging and Research on the Locomotive Diseases of Equidae (CIRALE) in the Calvados region. The dosimetric assessment was carried out for the different operators during the successive stages of the scintigraphic examination. Assuming 150 examinations per year, the annual equivalent dose to the fingers skin is 150 mSv maximum for the technologist and 2 mSv for the veterinary surgeon; the annual effective dose ranges from 0.15 to 0.45 mSv, depending on the operators. (authors)

  4. Dosimetric Characteristics of Radio-Photoluminescent Glass Dosimeters for Medical Applications: Linearity

    Energy Technology Data Exchange (ETDEWEB)

    Shehzadi, N. N.; Jeong, J. P.; Kim, B. C.; Kim, I. J.; Yi, C. Y. [Center for Ionizing Radiation, Korea Research Institute of Standards and Science, Seoul (Korea, Republic of)

    2017-04-15

    Radio-photoluminescent glass dosimeter (GD) has advantage of non-destructive reading process, negligible fading and superior radiation detection characteristics than other personal dosimeters like thermoluminescent dosimeters (TLD) or film dosimeters. In this study, one dosimetric characteristic of GDs, dose linearity was evaluated with two different approaches: one for each set of GDs selected and another for a batch of them using accumulated doses of same set of GDs and GDs in a batch, respectively. Within a dose range upto 10 Gy, not only each set of GDs but also a batch of them showed excellent linearity. Within a dose range upto 10 Gy, not only each set of GDs but also a batch of them showed excellent linearity.

  5. Qualitative dosimetric system for radiation processing. Technology for pilot scale preparation

    International Nuclear Information System (INIS)

    Moraru, R.

    1998-01-01

    Good manufacturing practice for radiation processing requires a very strictly tracking of the processed products. A method of labelling and identification of the irradiated and nonirradiated products is required. The qualitative dosimetric system provides a fast method for monitoring the product flow. Such dosimeters are attached on each product box, usually as labels, and offer a YES/NO information about the passing of products through the radiation field. Usually, this information consists in a change of colour. The qualitative dosimetric system that we realised is based on the degradation of polyvinylchloride (PVC) under radiation field. An amount of hydrochloric acid is released in this reaction. A pH indicator, included in the system, changes its colour at different absorbed dose. The changes of colour happened in a certain pH interval called turning range. We used as pH indicator the RED CONGO colorant with turning range of pH = 3 to 5 (from blue to red). A schematic view of the qualitative dosimeter is given. The initial colour is red and it continuously changes to brown, at 1 kGy absorbed dose, and to blue-green, for 5-100 kGy. The main features of this qualitative dosimetric system are: - Quick and easy to read information about product passing through radiation field; - Absorbed dose range, 1-300 kGy; - Independence of absorbed dose rate in the interval 5-100 kGy/h; - Stability, 3 year in the dark and 1 year in sun light; - Good reproducibility. The preparation technology consists in the following steps: 1. Preparation of the solutions: a) PVC in cyclohexanone solution b) RED CONGO in water solution; 2. Preparation of the system support consisting in dropping the PVC solution on adhesive labels; 3. Sample preparation consists in dropping the colorant solution on the system support; 4. Batch trial tests. The trial test was performed at IETI 10000 irradiation plant belonging to IFIN-HH and the reference absorbed dose was determined by Fricke dosimetry. The

  6. Dosimetric behavior of thermoluminescent dosimeters at low doses in diagnostic radiology

    International Nuclear Information System (INIS)

    Del Sol F, S.; Garcia S, R.; Guzman M, J.; Sanchez G, D.; Rivera M, T.; Ramirez R, G.; Gaona, E.

    2015-10-01

    Thermoluminescent (Tl) characteristics of TLD-100, LiF:Mg,Cu,P, and CaSO 4 : Dy the under homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescent dosimetry is presented. The irradiations were performed utilizing an X-ray beam generated by a Radiology Mexican Company: MRH-II E GMX 325-AF SBV-1 model, with Rotating Anode X-Ray Tube installed in the Hospital Juarez Norte de Mexico in Mexico City. Different thermoluminescent characteristics of dosimetric material were studied, such as, batch homogeneity, Tl glow curve, Tl response as a function of X-ray dose, reproducibility and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and positioned in a generic Phantom was used. Dose verification and comparison with the measurements made with that obtained by TLD-100 were analyzed. Preliminary results indicate the dosimetric peak appears at 243, 236 and 277 ± 5 degrees C respectively, these peaks are in agreement with that reported in the literature. Tl glow curve as a function of X-ray dose showed a linearity in the range from 1.76 mGy up to 14.70 mGy for all materials. Fading for a period of one month at room temperature showed low fading LiF:Mg,Cu,P, medium and high for TLD-100 and CaSO 4 : Dy. The results suggest that the three materials are suitable for measurements at low doses in radiodiagnostic, however, for its dosimetric characteristics are most effective for individual applications: personal dosimetry and monitors limb (LiF:Mg,Cu,P), clinical dosimetry and environmental (TLD-100 and CaSO 4 : Dy). (Author)

  7. Dosimetric evaluation of lithium carbonate (Li2CO3) as a dosemeter for gamma-radiation dose measurements.

    Science.gov (United States)

    Popoca, R; Ureña-Núñez, F

    2009-06-01

    This work reports the possibility of using lithium carbonate as a dosimetric material for gamma-radiation measurements. Carboxi-radical ions, CO(2)(-) and CO(3)(-), arise from the gamma irradiation of Li(2)CO(3), and these radical ions can be quantified by electron paramagnetic resonance (EPR) spectrometry. The EPR-signal response of gamma-irradiated lithium carbonate has been investigated to determine some dosimetric characteristics such as: peak-to-peak signal intensity versus gamma dose received, zero-dose response, signal fading, signal repeatability, batch homogeneity, dose rate effect and stability at different environmental conditions. Using the conventional peak-to-peak method of stable ion radicals, it is concluded that lithium carbonate could be used as a gamma dosemeter in the range of 3-100 Gy.

  8. Dosimetric and patient correlates of quality of life after prostate stereotactic ablative radiotherapy

    International Nuclear Information System (INIS)

    Elias, Evelyn; Helou, Joelle; Zhang, Liying; Cheung, Patrick; Deabreu, Andrea; D’Alimonte, Laura; Sethukavalan, Perakaa; Mamedov, Alexandre; Cardoso, Marlene; Loblaw, Andrew

    2014-01-01

    Background and purpose: Initial results of Stereotactic Ablative Body Radiotherapy (SABR) in the treatment of localized prostate cancer appear promising however long-term quality of life (QOL) outcomes and dosimetric correlates are necessary. Material and methods: A phase I/II study was performed where low risk prostate cancer patients received SABR 35 Gy in 5 fractions, once weekly. Patient self-reported QOL was measured using the Expanded Prostate Cancer Index Composite (EPIC) at baseline and q6 month up to 5 years. Urinary, bowel and sexual domains were analyzed. A minimally clinical important change (MCIC) was defined as 0.5 ∗ standard deviation of the baseline. Univariate and multivariate logistic regression were used to identify dosimetric predictors of MCIC. Results: 84 patients were included. The median follow-up was 50.8 months (interquartile range [IQR], 44.7–56.3). 17.9%, 26.2% and 37.5% of patients reported worse QOL on follow up in the urinary, bowel and sexual domains respectively. On univariate analysis Rectal V31.8 > 10%, D1cc > 35 Gy were associated with bowel MCIC, penile bulb (PB) V35 > 4%, V20 > 40% with sexual MCIC. Of these factors only rectal D1cc and PB V35 were predictors of worse QOL on multivariate analysis. Conclusions: Long-term single-institution QOL outcomes are encouraging. Rigorous dosimetric constraints are needed to keep bothersome side effects low

  9. The role of the Secondary Laboratory of Dosimetric calibration in the implementation of the dosimetric magnitudes with radiological protection aims

    International Nuclear Information System (INIS)

    Perez Medina O, V.; Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    It is very well-known the paper of the net of secondary laboratories of dosimetric calibration of the OAS in the dissemination of the traceability of the dosimetric magnitudes: kerma in air and absorbed dose in water, to the radiotherapy departments, given the high accuracy and precision that require the radiotherapy treatments. However the LSCD has other important areas at least for the development, implementation and evaluation of dosimetric magnitudes denominated operative magnitudes with ends of radiological protection: environmental equivalent dose H*(10), directional equivalent dose H'(0.07) and personal equivalent dose Hp. In the case of radiological protection the LSCD-ININ has been implementing the infrastructure to give service of personal dosimetry for photons and beta particles in terms of the operative magnitudes. For photons: X and gamma rays, it account with a secondary pattern camera PTW T34035 gauged in H * and Hp in the primary laboratory of Germany PTB. For the case of beta radiation its account with an extrapolation camera PTW 23392 with a secondary pattern kit of sources of the type I, gauged in terms of H'(0.07) in the PTB. (Author)

  10. ARDENT to develop advanced dosimetric techniques

    CERN Document Server

    Antonella Del Rosso

    2012-01-01

    Earlier this week, the EU-supported Marie Curie training network ARDENT kicked off at a meeting held at CERN. The overall aim of the project is the development of advanced instrumentation for radiation dosimetry. The applications range from radiation measurements around particle accelerators, onboard commercial flights and in space, to the characterization of radioactive waste and medicine, where accurate dosimetry is of vital importance.   The ARDENT (Advanced Radiation Dosimetry European Network Training) project is both a research and a training programme, which aims at developing new dosimetric techniques while providing 15 Early-Stage Researchers (ESR) with state-of-the-art training. The project, coordinated by CERN, is funded by the European Union with a contribution of about 3.9 million euros over four years. The ARDENT initiative will focus on three main technologies: gas detectors, in particular Gas Electron Multipliers (GEM) and Tissue Equivalent Proportional Counters (TEPC); solid stat...

  11. Benchmarking Dosimetric Quality Assessment of Prostate Intensity-Modulated Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Senthi, Sashendra, E-mail: sasha.senthi@petermac.org [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Gill, Suki S. [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Haworth, Annette; Kron, Tomas; Cramb, Jim [Department of Physical Sciences, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Rolfo, Aldo [Radiation Therapy Services, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Thomas, Jessica [Biostatistics and Clinical Trials, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Duchesne, Gillian M. [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia); Hamilton, Christopher H.; Joon, Daryl Lim [Radiation Oncology Department, Austin Repatriation Hospital, Heidelberg, VIC (Australia); Bowden, Patrick [Radiation Oncology Department, Tattersall' s Cancer Center, East Melbourne, VIC (Australia); Foroudi, Farshad [Division of Radiation Oncology, Peter MacCallum Cancer Center, East Melbourne, VIC (Australia)

    2012-02-01

    Purpose: To benchmark the dosimetric quality assessment of prostate intensity-modulated radiotherapy and determine whether the quality is influenced by disease or treatment factors. Patients and Methods: We retrospectively analyzed the data from 155 consecutive men treated radically for prostate cancer using intensity-modulated radiotherapy to 78 Gy between January 2007 and March 2009 across six radiotherapy treatment centers. The plan quality was determined by the measures of coverage, homogeneity, and conformity. Tumor coverage was measured using the planning target volume (PTV) receiving 95% and 100% of the prescribed dose (V{sub 95%} and V{sub 100%}, respectively) and the clinical target volume (CTV) receiving 95% and 100% of the prescribed dose. Homogeneity was measured using the sigma index of the PTV and CTV. Conformity was measured using the lesion coverage factor, healthy tissue conformity index, and the conformity number. Multivariate regression models were created to determine the relationship between these and T stage, risk status, androgen deprivation therapy use, treatment center, planning system, and treatment date. Results: The largest discriminatory measurements of coverage, homogeneity, and conformity were the PTV V{sub 95%}, PTV sigma index, and conformity number. The mean PTV V{sub 95%} was 92.5% (95% confidence interval, 91.3-93.7%). The mean PTV sigma index was 2.10 Gy (95% confidence interval, 1.90-2.20). The mean conformity number was 0.78 (95% confidence interval, 0.76-0.79). The treatment center independently influenced the coverage, homogeneity, and conformity (all p < .0001). The planning system independently influenced homogeneity (p = .038) and conformity (p = .021). The treatment date independently influenced the PTV V{sub 95%} only, with it being better at the start (p = .013). Risk status, T stage, and the use of androgen deprivation therapy did not influence any aspect of plan quality. Conclusion: Our study has benchmarked measures

  12. A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Son, Jaeman; Baek, Taesung; Lee, Boram; Shin, Dongho; Park, Sung Yong; Park, Jeonghoon; Lim, Young Kyung; Lee, Se Byeong; Kim, Jooyoung; Yoon, Myonggeun

    2015-01-01

    This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA

  13. A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy.

    Science.gov (United States)

    Son, Jaeman; Baek, Taesung; Lee, Boram; Shin, Dongho; Park, Sung Yong; Park, Jeonghoon; Lim, Young Kyung; Lee, Se Byeong; Kim, Jooyoung; Yoon, Myonggeun

    2015-09-01

    This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film, a diode array (Mapcheck), an ion chamber array (MatriXX) and an electronic portal imaging device (EPID) for patient-specific QA. The measured doses from the four dosimetric tools were compared with the dose calculated by the treatment planning system. The passing rates of the four dosimetric tools were calculated using the gamma index method, using as criteria a dose difference of 3% and a distance-to-agreement of 3 mm. The QA results based on Mapcheck, MatriXX and EPID showed good agreement, with average passing rates of 99.61%, 99.04% and 99.29%, respectively. However, the average passing rate based on film measurement was significantly lower, 95.88%. The average uncertainty (1 standard deviation) of passing rates for 6 intensity modulated fields was around 0.31 for film measurement, larger than those of the other three dosimetric tools. QA results and consistencies depend on the choice of dosimetric tool. Universal passing rates should depend on the normalization or inter-comparisons of dosimetric tools if more than one dosimetric tool is used for patient specific QA.

  14. Dosimetric monitoring at time of Chernobyl clean-up. A retrospective view

    International Nuclear Information System (INIS)

    Chumak, V.V.; Bakhanova, E.V.; Musijachenko, N.V.; Krjuchkov, V.P.

    2000-01-01

    Although at time of the accident many thousands of individuals were subjected to personal dosimetric monitoring, a status of dosimetric support of clean-up activities performed in 1986-1987 remains one of the most uncertain radiological issues related to Chernobyl accident. It is known that the scope, practical coverage and methodologies of dosimetry at time of the accident significantly varied. Unfortunately, the dose records available now in a number registries and databases are lacking direct indications of the methods of dosimetry, locations of work and tasks performed by liquidators. Moreover, data record linkage in many cases is problematic due to lack of unique identifiers in the databases of concern. However, this information, collected in course of dosimetric monitoring is extremely valuable for epidemiological consideration of this cohort and, therefore, cannot be neglected because of problems with strait forward application of this data. Retrospective consideration of dosimetric monitoring data was conducted along several lines. First, data sets (in some cases impersonal), related to the known dosimetric practices were studied in order to determine regularities in their dose distributions, evaluate possible distortions caused by extraneous admixtures to dose arrays and evaluate possible contribution of falsified dose records. Another effort was directed towards individualization of information regarding affiliation and tasks of the liquidators included into the State Chernobyl Registry (SCR), which is, essentially, the main pool of subjects for observation in the framework of post Chernobyl epidemiological studies. The SCR in its original shape was missing this crucial information. In order to recover this information gap, a wide scale postal survey of liquidators was undertaken. Those persons who are included into the State Chernobyl Registry and have official dose records were asked to respond to a simple five-entry questionnaire, dealing with their

  15. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  16. Transport and dosimetric solutions for the ELIMED laser-driven beam line

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Romano, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Scuderi, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Amato, A. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Candiano, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Cuttone, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Giove, D. [INFN Sezione di Milano, Via Celoria 16, Milano (Italy); Korn, G.; Krasa, J. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Leanza, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Manna, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Maggiore, M. [INFN-LNL, Viale dell' Universitá 2 - 35020 Legnaro (PD) (Italy); Marchese, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Margarone, D. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Milluzzo, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Petringa, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Sabini, M.G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Azienda Ospedaliera Cannizzaro, Via Messina 829 - 95100 Catania (Italy); Schillaci, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); and others

    2015-10-01

    Within 2017, the ELIMED (ELI-Beamlines MEDical applications) transport beam-line and dosimetric systems for laser-generated beams will be installed at the ELI-Beamlines facility in Prague (CZ), inside the ELIMAIA (ELI Multidisciplinary Applications of laser–Ion Acceleration) interaction room. The beam-line will be composed of two sections: one in vacuum, devoted to the collecting, focusing and energy selection of the primary beam and the second in air, where the ELIMED beam-line dosimetric devices will be located. This paper briefly describes the transport solutions that will be adopted together with the main dosimetric approaches. In particular, the description of an innovative Faraday Cup detector with its preliminary experimental tests will be reported.

  17. Improvements in critical dosimetric endpoints using the Contura multilumen balloon breast brachytherapy catheter to deliver accelerated partial breast irradiation: preliminary dosimetric findings of a phase iv trial.

    Science.gov (United States)

    Arthur, Douglas W; Vicini, Frank A; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    Dosimetric findings in patients treated with the Contura multilumen balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional Phase IV registry trial are presented. Computed tomography-based three-dimensional planning with dose optimization was performed. For the trial, new ideal dosimetric goals included (1) ≥95% of the prescribed dose (PD) covering ≥90% of the target volume, (2) a maximum skin dose ≤125% of the PD, (3) maximum rib dose ≤145% of the PD, and (4) the V150 ≤50 cc and V200 ≤10 cc. The ability to concurrently achieve these dosimetric goals using the Contura MLB was analyzed. 144 cases were available for review. Using the MLB, all dosimetric criteria were met in 76% of cases. Evaluating dosimetric criteria individually, 92% and 89% of cases met skin and rib dose criteria, respectively. In 93% of cases, ideal target volume coverage goals were met, and in 99%, dose homogeneity criteria (V150 and V200) were satisfied. When skin thickness was ≥5 mm to <7 mm, the median skin dose was limited to 120.1% of the PD, and when skin thickness was <5 mm, the median skin dose was 124.2%. When rib distance was <5 mm, median rib dose was reduced to 136.5% of the PD. When skin thickness was <7 mm and distance to rib was <5 mm, median skin and rib doses were jointly limited to 120.6% and 142.1% of the PD, respectively. The Contura MLB catheter provided the means of achieving the imposed higher standard of dosimetric goals in the majority of clinical scenarios encountered. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  19. Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer

    International Nuclear Information System (INIS)

    Aebersold, D.M.; Isaak, B.; Behrensmeier, F.; Kolotas, C.; Mini, R.; Greiner, R.H.; Thalmann, G.; Kranzbuehler, H.

    2004-01-01

    Background and purpose: analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. Patients and methods: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. Results: at the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm 3 and in dimensions (width, height, length) from -1.1 to 1.0 cm. Conclusion: preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality

  20. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    International Nuclear Information System (INIS)

    Fung, K.L.

    2004-01-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV p in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations

  1. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.L. E-mail: orkarl@polyu.edu.hk

    2004-05-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV{sub p} in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations.

  2. Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.

    Science.gov (United States)

    Estabrook, Neil C; Corn, Jonathan B; Ewing, Marvene M; Cardenes, Higinia R; Das, Indra J

    2018-02-01

    Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer. Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively. Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed. CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.

  3. Dosimetric commissioning and system for stereotactic radiation treatments based on linear accelerators with dynamic micromultilaminas collimators

    International Nuclear Information System (INIS)

    Ascension, Yudy; Alfonso, Rodolfo; Silvestre, Ileana

    2009-01-01

    Once installed and accepted, a system for stereotactic radiosurgery / stereotactic radiotherapy (CERs / RTE) requires, before starting to be used clinically in patients undergoing a process of commissioning dosimetry, which evaluates all geometric parameters, physical, Dosimetric and technical impact on the precision and accuracy of treatment to administer, and therefore its effectiveness. This process includes training and familiarization of the multidisciplinary team (medical physicists, radiation oncologists, neurosurgeons, dosimetrists, biomedical engineers) with the equipment and techniques used, the quality assurance program and special radiation protection standards for this technology. The aim of this work is to prepare the pre-clinical dosimetric conditions to ensure the quality and radiation safety of treatment with CER RTE. Treatment with CER RTE INOR has a linear accelerator equipped with a micro-multileaf collimator dynamic tertiary (dMLC 3Dline). The system aceleradordMLC geometric and dosimetric was calibrated, using ionization chambers miniature, diode and film dosimetry. The immobilization of the patient and location of the lesion is made by both invasive stereotactic frames and relocatable. The computerized planning of the CER / TEN is done with the ERGO system, for which commissioning is designed test cases of increasing complexity, using planes and anthropomorphic dummies, which help assess the accuracy of the dosimetric calculations and accuracy of the system as a whole. We compared the results of the planning system with measurements, showing that the discrepancies are within tolerances, so it is concluded that from the standpoint of physical dosimetry, the system-under-ERGO accelerator MLC is eligible for clinical use. (author)

  4. Synthesis and characterization of CaF{sub 2}:Dy nanophosphor for dosimetric application

    Energy Technology Data Exchange (ETDEWEB)

    Bhadane, Mahesh S.; Dahiwale, S. S.; Bhoraskar, V. N.; Dhole, S. D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune-411007 (India); Patil, B. J. [Department of Physics, Abasaheb Garware College, Pune-411004 (India); Kulkarni, M. S. [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Bhatt, B. C. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2015-06-24

    In this work, nanoparticles (NPs) of dysprosium doped calcium fluoride (CaF{sub 2}:Dy) 1 mol % has been prepared using simple chemical co-precipitation method and its thermoluminescence (TL) dosimetric properties were studied. The synthesized nanoparticle sample was characterized by X-ray diffraction (XRD) and the particle size of face centered cubic phase NPs was found around 30 nm. The shape, morphology and size were also observed by scanning electron microscopy (SEM). From gamma irradiated CaF{sub 2}:Dy TL curves, it was observed that the total areas of all the glow peak intensities are dramatically changed with increase in annealing temperature. Further, TL glow curve of the CaF{sub 2}:Dy at 183 °C annealed at 400 °C, showed very sharp linear response in the dose range from 1 Gy to 750 Gy. This linear response of CaF{sub 2}:Dy nanophosphor as a function of gamma dose is very useful from radiation dosimetric point of view.

  5. IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Atamtuerk, Alper; Hsu, I-Chow; Pouliot, Jean; Goldberg, Ken

    2011-01-01

    Purpose: Many planning methods for high dose rate (HDR) brachytherapy require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to develop a new approach for HDR brachytherapy by directly optimizing the dose distribution based on dosimetric criteria. Methods: The authors developed inverse planning by integer program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. They used their heuristic to compute dose plans for 20 anonymized prostate cancer image data sets from patients previously treated at their clinic database. Dosimetry was evaluated and compared to dosimetric criteria. Results: Dose plans computed from IPIP satisfied all given dosimetric criteria for the target and healthy tissue after a single iteration. The average target coverage was 95%. The average computation time for IPIP was 30.1 s on an Intel(R) Core TM 2 Duo CPU 1.67 GHz processor with 3 Gib RAM. Conclusions: IPIP is an HDR brachytherapy planning system that directly incorporates dosimetric criteria. The authors have demonstrated that IPIP has clinically acceptable performance for the prostate cases and dosimetric criteria used in this study, in both dosimetry and runtime. Further study is required to determine if IPIP performs well for a more general group of patients and dosimetric criteria, including other cancer sites such as GYN.

  6. EPR dosimetric properties of 2-methylalanine pellet for radiation processing application

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Ali, Laila I.; Moustafa, H.; Tadros, Soad M.

    2014-01-01

    The dosimetric characteristics of γ-radiation induced free radicals in 2-methylalanine (2MA) pellet dosimeter are investigated using electron paramagnetic resonance (EPR) in the high-dose range of 1–100 kGy. The EPR spectrum of γ-irradiated 2MA exhibits an isotropic EPR signal with seven lines. The dosimeter response is humidity independent in the range of 33–76% relative humidity. The manufactured dosimeter is typically adipose tissue equivalent in the energy level of 0.1–15 MeV. The overall uncertainty (2σ) of the dosimeter is less than 6.9%. - Highlights: • Preparation of 2-methyl alanine pellets for high-dose dosimetry (1–100 kGy). • The dosimeter response is humidity independent in 33–76% relative humidity range during irradiation. • The temperature coefficient equals 0.96%/°C in the range of 21–60 °C. • Overall uncertainty of the dosimeter not exceeds 6.9% at 2σ

  7. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    International Nuclear Information System (INIS)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B.; Sakuraba, Roberto K.; Goncalves, Vinicius D.

    2011-01-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  8. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B., E-mail: esmoura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Goncalves, Vinicius D. [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-07-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  9. Dosimetric effects of an air cavity for the SAVI partial breast irradiation applicator

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Susan L.; Pino, Ramiro [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, Methodist Hospital, Houston, Texas 77030 and Texas Cancer Clinic, San Antonio, Texas 78240 (United States)

    2010-08-15

    Purpose: To investigate the dosimetric effect of the air inside the SAVI partial breast irradiation device. Methods: The authors have investigated how the air inside the SAVI partial breast irradiation device changes the delivered dose from the homogeneously calculated dose. Measurements were made with the device filled with air and water to allow comparison to a homogenous dose calculation done by the treatment planning system. Measurements were made with an ion chamber, TLDs, and film. Monte Carlo (MC) simulations of the experiment were done using the EGSnrc suite. The MC model was validated by comparing the water-filled calculations to those from a commercial treatment planning system. Results: The magnitude of the dosimetric effect depends on the size of the cavity, the arrangement of sources, and the relative dwell times. For a simple case using only the central catheter of the largest device, MC results indicate that the dose at the prescription point 1 cm away from the air-water boundary is about 9% higher than the homogeneous calculation. Independent measurements in a water phantom with a similar air cavity gave comparable results. MC simulation of a realistic multidwell position plan showed discrepancies of about 5% on average at the prescription point for the largest device. Conclusions: The dosimetric effect of the air cavity is in the range of 3%-9%. Unless a heterogeneous dose calculation algorithm is used, users should be aware of the possibility of small treatment planning dose errors for this device and make modifications to the treatment delivery, if necessary.

  10. Effective atomic numbers and electron density of dosimetric material

    Directory of Open Access Journals (Sweden)

    Kaginelli S

    2009-01-01

    Full Text Available A novel method for determination of mass attenuation coefficient of x-rays employing NaI (Tl detector system and radioactive sources is described.in this paper. A rigid geometry arrangement and gating of the spectrometer at FWHM position and selection of absorber foils are all done following detailed investigation, to minimize the effect of small angle scattering and multiple scattering on the mass attenuation coefficient, m/r, value. Firstly, for standardization purposes the mass attenuation coefficients of elemental foils such as Aluminum, Copper, Molybdenum, Tantalum and Lead are measured and then, this method is utilized for dosimetric interested material (sulfates. The experimental mass attenuation coefficient values are compared with the theoretical values to find good agreement between the theory and experiment within one to two per cent. The effective atomic numbers of the biological substitute material are calculated by sum rule and from the graph. The electron density of dosimetric material is calculated using the effective atomic number. The study has discussed in detail the attenuation coefficient, effective atomic number and electron density of dosimetric material/biological substitutes.

  11. Dosimetric system for measurement of radioactive contaminations

    International Nuclear Information System (INIS)

    Litynski, Z.; Pienkos, J.P.; Witkowski, J.; Zadrozny, S.

    1985-01-01

    A dosimetric system for personnel dosimetry and monitoring measuring a contamination without time delay and dead time is described. The system ensures many-point measurement and minimalization of background radiation influence. 1 fig. (A.S.)

  12. TU-D-9A-01: TG176: Dosimetric Effects of Couch Tops and Immobilization Devices

    International Nuclear Information System (INIS)

    Olch, A

    2014-01-01

    The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices are often overlooked. These devices also increase surface dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased surface dose compared to the ‘tennis racket’ style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations we make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of skin dose and attenuation, how to report these values, and for the vendors, an appeal is made to work together to provide accurate couch top models in planning systems. Learning Objectives

  13. Evaluation of Specific Absorption Rate as a Dosimetric Quantity for Electromagnetic Fields Bioeffects

    OpenAIRE

    Panagopoulos, Dimitris J.; Johansson, Olle; Carlo, George L.

    2013-01-01

    PURPOSE: To evaluate SAR as a dosimetric quantity for EMF bioeffects, and identify ways for increasing the precision in EMF dosimetry and bioactivity assessment. METHODS: We discuss the interaction of man-made electromagnetic waves with biological matter and calculate the energy transferred to a single free ion within a cell. We analyze the physics and biology of SAR and evaluate the methods of its estimation. We discuss the experimentally observed non-linearity between electromagnetic exposu...

  14. Improvement in the dosimetric CaSO4: Dy obtention method

    International Nuclear Information System (INIS)

    Campos, L.L.; Frutuoso, P.H.; Souto, V.J.

    1989-08-01

    With the purpose of saving up in the dosimetric CaSO 4 : Dy production, a new method was developed to obtain single crystals. In this method the nitrogen flux used to carry the acid vapour was substituted by compressed air. It was compared all dosimetric properties of the crystals. There is no alteration in the glow curve. The sensitivity is the same in both cases and the lower detection limit is 3.8 x 10 -8 C.Kg -1 (150 μR) [pt

  15. Dosimetric characterization of KMgF3:Tb+PTFE

    International Nuclear Information System (INIS)

    Ramirez R, M. I.; Garcia S, L.; Villicana M, M.; Huirache A, R.; Apolinar C, J.; Gonzalez M, P. R.

    2017-10-01

    In this work the results obtained from the dosimetric characterization of the new radiation detectors of KMgF 3 :Tb+PTFE are presented. The host salt was obtained by means of the microwave technique, with the polycrystalline powder obtained, dosimeters were made in tablet form, using as Ptfe binder. The thermoluminescent response of these new detectors presented a linear behavior, in the dose range between 1 and 1000 Gy of 60 Co gamma radiation, the reproducibility test in the measurements, during ten cycles of heat treatment, irradiation and reading presented ± 3.7% Ds, in the stability test of thermoluminescent signal, during two months showed that the fading is practically null. Due to the results obtained, this new detector could be very useful for the dosimetry of ionizing radiation in different clinical applications. (Author)

  16. New routes of preparation of polyaniline films and dosimetric characterization for high-doses gamma radiation

    International Nuclear Information System (INIS)

    Pacheco, Ana Paula Lima

    2003-08-01

    This work presents a new conducting polymeric material based on polyaniline thin films that will be used in the confection of dosimetric devices. On preparation of the films a homogeneous and viscous solution of poly (acrylic acid) and MnO 2 is deposited on PMMA surface, which after dried, is immersed in an acid aniline solution. The films formed present low resistivity (6.10 2 Ωm), good mechanical resistance and adherence on the electrodes. The films were characterized by infrared spectroscopy, conductivity measurements and manganese elemental analyses. The resistance variations show linear correlation (r 2 = 0,9928) with gamma irradiation dose in the range of 1000 to 6000 Gy, with medium error less than 5% and sensitivity response. The dosimetric devices present as advantage real time measurements, low cost, use in calibration of industrial radioactive sources. Moreover, this composite could in future replace Fricke dosimeter and its applications. A calibration curve is showed for PANI dosimeter, here proposed, to use at high gamma doses. (author)

  17. Organ motion study and dosimetric impact of respiratory gating radiotherapy for esophageal cancer

    International Nuclear Information System (INIS)

    Lorchel, F.

    2007-04-01

    Chemoradiotherapy is now the standard treatment for locally advanced or inoperable esophageal carcinoma. In this indication, conformal radiotherapy is generally used. However, prognosis remains poor for these patients. Respiratory gating radiotherapy can decrease healthy tissues irradiation and allows escalation dose in lung, liver and breast cancer. In order to improve radiotherapy technique, we propose to study the feasibility of respiratory gating for esophageal cancer. We will study the respiratory motions of esophageal cancer to optimize target volume delineation, especially the internal margin (I.M.). We will test the correlation between tumour and chest wall displacements to prove that esophageal cancer motions are induced by respiration. This is essential before using free breathing respiratory gating systems. We will work out the dosimetric impact of respiratory gating using various dosimetric analysis parameters. We will compare dosimetric plans at end expiration, end inspiration and deep inspiration with dosimetric plan in free-breathing condition. This will allow us to establish the best respiratory phase to irradiate for each gating system. This dosimetric study will be completed with linear quadratic equivalent uniform dose (E.U.D.) calculation for each volume of interest. Previously, we will do a theoretical study of histogram dose volume gradation to point up its use. (author)

  18. Sparing of the hippocampus and limbic circuit during whole brain radiation therapy: a dosimetric study using helical tomotherapy

    International Nuclear Information System (INIS)

    Marsh, J.C.; Gielda, B.T.; Herskovic, A.M.; Turian, J.V.

    2010-01-01

    Full text: The study aims to assess the feasibility of dosimetrically sparing the limbic circuit during whole brain radiation therapy (WBRT) and prophylactic cranial irradiation (PCI). Methods and Materials: We contoured the brain/brainstem on fused MRI and CT as the target volume (PTV) in 11 patients, excluding the hippocampus and the rest of the limbic circuit, which were considered organs at risk (OARs). PCI and WBRT helical tomotherapy plans were prepared for each patient with a 1.0-cm field width, pitch 0.285, initial modulation factor = 2.5. We attempted to spare the hippocampus and the rest of the limbic circuit while treating the rest of the brain to 30 Gy in 15 fractions (PCI) or 35 Gy in 14 fractions (WBRT) with VlOO ∼ 95%. The quality of the plans was assessed by calculating mean dose and equivalent uniform dose (EUD) for OARs and the % volume of the PTV receiving the prescribed dose, V 100. Results: In the PCI plans, mean doses/EUD were: hippocampus 12.5 Gy/ 14.23 Gy, rest of limbic circuit 17.0 Gy/19.02 Gy. In the WBRT plans, mean doses/EUD were: hippocampus 14.3 Gy/16.07 Gy, rest of limbic circuit 17.9 Gy/20.74 Gy. The mean VlOO for the rest of the brain (PTV) were 94.7% (PCl) and 95.1 % (WBRT). Mean PCI and WBRT treatment times were essentially identical (mean 15.23 min, range 14.27-17.5). Conclusions: It is dosimetrically feasible to spare the hippocampus and the rest of the limbic circuit using helical tomotherapy while treating the rest of the brain to full dose.

  19. Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

    International Nuclear Information System (INIS)

    Beltran, Chris; Trussell, John; Merchant, Thomas E.

    2010-01-01

    The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 ± 1.5 treatment fractions; motion data were acquired for a mean of 26 ± 6.2 fractions. The mean age was 15.6 ± 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

  20. Dosimetric properties of a radiochromic gel detector for diagnostic X-rays

    International Nuclear Information System (INIS)

    Bero, M.A.

    2007-01-01

    The gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. The Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different responses for low- and medium-energy X-rays in comparison with high-energy γ-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response, other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100-300 kV. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0-20 Gy

  1. EPR dosimetric properties of nano-barium sulfate

    International Nuclear Information System (INIS)

    Aboelezz, E.; Hassan, G.M.; Sharaf, M.A.; El-Khodary, A.

    2015-01-01

    Nano/micro BaSO 4 were prepared through the co-precipitation method to measure ionizing radiation doses using electron paramagnetic resonance (EPR). The nano-BaSO 4 sample was characterized using X-ray diffraction (XRD), and transmission electron microscopy (TEM) techniques. The dose response and fading properties of nano- and micro-phase BaSO 4 were compared in EPR spectra. The prepared nano- and micro-BaSO 4 samples have the same hole and electron centers, which may be attributed to SO 4 − and SO 3 − , respectively. The dosimetric signals for prepared nano- and micro-BaSO 4 have spectroscopic splitting factor (g) with values 2.0025±0.0006 and 2.0027±0.0006, respectively. The nanocrystalline sample has a linear γ-ray dose response over the range 0.4 Gy–1 kGy. The performance parameters which including detection limit and critical level calculated from weighted and unweighted least-squares fitting. The sensitivity of nano-BaSO 4 to γ-ray is one and a half times more than alanine. The lifetime and activation energy for nano-BaSO 4 were estimated by conducting a thermal stability study, and were 5.7±1.1×10 4 years and 0.73±0.14 eV, respectively. The combined and expanded uncertainties accompanying measurements were ±3.89% and ±7.78%, respectively. - Highlights: • Preparation of nano-BaSO 4 using the co-precipitation method. • Study of the dosimetric properties of nano-barium sulfate using the EPR technique. • Comparison between a new EPR dosimeter using nano-materials and standard alanine. • Calculation of the uncertainty budget for nano-BaSO 4

  2. Patient feature based dosimetric Pareto front prediction in esophageal cancer radiotherapy.

    Science.gov (United States)

    Wang, Jiazhou; Jin, Xiance; Zhao, Kuaike; Peng, Jiayuan; Xie, Jiang; Chen, Junchao; Zhang, Zhen; Studenski, Matthew; Hu, Weigang

    2015-02-01

    To investigate the feasibility of the dosimetric Pareto front (PF) prediction based on patient's anatomic and dosimetric parameters for esophageal cancer patients. Eighty esophagus patients in the authors' institution were enrolled in this study. A total of 2928 intensity-modulated radiotherapy plans were obtained and used to generate PF for each patient. On average, each patient had 36.6 plans. The anatomic and dosimetric features were extracted from these plans. The mean lung dose (MLD), mean heart dose (MHD), spinal cord max dose, and PTV homogeneity index were recorded for each plan. Principal component analysis was used to extract overlap volume histogram (OVH) features between PTV and other organs at risk. The full dataset was separated into two parts; a training dataset and a validation dataset. The prediction outcomes were the MHD and MLD. The spearman's rank correlation coefficient was used to evaluate the correlation between the anatomical features and dosimetric features. The stepwise multiple regression method was used to fit the PF. The cross validation method was used to evaluate the model. With 1000 repetitions, the mean prediction error of the MHD was 469 cGy. The most correlated factor was the first principal components of the OVH between heart and PTV and the overlap between heart and PTV in Z-axis. The mean prediction error of the MLD was 284 cGy. The most correlated factors were the first principal components of the OVH between heart and PTV and the overlap between lung and PTV in Z-axis. It is feasible to use patients' anatomic and dosimetric features to generate a predicted Pareto front. Additional samples and further studies are required improve the prediction model.

  3. Influence of Pro-Qura-generated Plans on Postimplant Dosimetric Quality: A Review of a Multi-Institutional Database

    International Nuclear Information System (INIS)

    Allen, Zachariah; Merrick, Gregory S.; Grimm, Peter; Blasko, John; Sylvester, John; Butler, Wayne; Chaudry, Usman-Ul-Haq; Sitter, Michael

    2008-01-01

    The influence of Pro-Qura-generated plans vs. community-generated plans on postprostate brachytherapy dosimetric quality was compared. In the Pro-Qura database, 2933 postplans were evaluated from 57 institutions. A total of 1803 plans were generated by Pro-Qura and 1130 by community institutions. Iodine-125 ( 125 I) plans outnumbered Palladium 103 ( 103 Pd) plans by a ratio of 3:1. Postimplant dosimetry was performed in a standardized fashion by overlapping the preimplant ultrasound and the postimplant computed tomography (CT). In this analysis, adequacy was defined as a V 100 > 80% and a D 90 of 90% to 140% for both isotopes along with a V 150 125 I and 103 Pd. The mean postimplant V 100 and D 90 were 88.6% and 101.6% vs. 89.3% and 102.3% for Pro-Qura and community plans, respectively. When analyzed in terms of the first 8 sequence groups (10 patients/sequence group) for each institution, Pro-Qura planning resulted in less postimplant variability for V 100 (86.2-89.5%) and for D 90 (97.4-103.2%) while community-generated plans had greater V 100 (85.3-91.2%) and D 90 (95.9-105.2%) ranges. In terms of sequence groups, postimplant dosimetry was deemed 'too cool' in 11% to 30% of cases and 'too hot' in 12% to 27%. On average, no clinically significant postimplant dosimetric differences were discerned between Pro-Qura and community-based planning. However, substantially greater variability was identified in the community-based plan cohort. It is possible that the Pro-Qura plan and/or the routine postimplant dosimetric evaluation may have influenced dosimetric outcomes at community-based centers

  4. Dosimetric Consequences of Interobserver Variability in Delineating the Organs at Risk in Gynecologic Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Damato, Antonio L.; Townamchai, Kanopkis; Albert, Michele; Bair, Ryan J.; Cormack, Robert A.; Jang, Joanne; Kovacs, Arpad; Lee, Larissa J.; Mak, Kimberley S.; Mirabeau-Beale, Kristina L.; Mouw, Kent W.; Phillips, John G.; Pretz, Jennifer L.; Russo, Andrea L.; Lewis, John H.; Viswanathan, Akila N.

    2014-01-01

    Purpose: To investigate the dosimetric variability associated with interobserver organ-at-risk delineation differences on computed tomography in patients undergoing gynecologic interstitial brachytherapy. Methods and Materials: The rectum, bladder, and sigmoid of 14 patients treated with gynecologic interstitial brachytherapy were retrospectively contoured by 13 physicians. Geometric variability was calculated using κ statistics, conformity index (CI gen ), and coefficient of variation (CV) of volumes contoured across physicians. Dosimetric variability of the single-fraction D 0.1cc and D 2cc was assessed through CV across physicians, and the standard deviation of the total EQD2 (equivalent dose in 2 Gy per fraction) brachytherapy dose (SD TOT ) was calculated. Results: The population mean ± 1 standard deviation of κ, CI gen , and volume CV were, respectively: 0.77 ± 0.06, 0.70 ± 0.08, and 20% ± 6% for bladder; 0.74 ± 06, 0.67 ± 0.08, and 20% ± 5% for rectum; and 0.33 ± 0.20, 0.26 ± 0.17, and 82% ± 42% for sigmoid. Dosimetric variability was as follows: for bladder, CV = 31% ± 19% (SD TOT = 72 ± 64 Gy) for D 0.1cc and CV = 16% ± 10% (SD TOT = 9 ± 6 Gy) for D 2cc ; for rectum, CV = 11% ± 5% (SD TOT = 16 ± 17 Gy) for D 0.1cc and CV = 7% ± 2% (SD TOT = 4 ± 3 Gy) for D 2cc ; for sigmoid, CV = 39% ± 28% (SD TOT = 12 ± 18 Gy) for D 0.1cc and CV = 34% ± 19% (SD TOT = 4 ± 4 Gy) for D 2cc. Conclusions: Delineation of bladder and rectum by 13 physicians demonstrated substantial geometric agreement and resulted in good dosimetric agreement for all dose-volume histogram parameters except bladder D 0.1cc. Small delineation differences in high-dose regions by the posterior bladder wall may explain these results. The delineation of sigmoid showed fair geometric agreement. The higher dosimetric variability for sigmoid compared with rectum and bladder did not correlate with higher variability in the total brachytherapy dose but rather may be due to the

  5. Computational model for dosimetric purposes in dental procedures

    International Nuclear Information System (INIS)

    Kawamoto, Renato H.; Campos, Tarcisio R.

    2013-01-01

    This study aims to develop a computational model for dosimetric purposes the oral region, based on computational tools SISCODES and MCNP-5, to predict deterministic effects and minimize stochastic effects caused by ionizing radiation by radiodiagnosis. Based on a set of digital information provided by computed tomography, three-dimensional voxel model was created, and its tissues represented. The model was exported to the MCNP code. In association with SICODES, we used the Monte Carlo N-Particle Transport Code (MCNP-5) method to play the corresponding interaction of nuclear particles with human tissues statistical process. The study will serve as a source of data for dosimetric studies in the oral region, providing deterministic effect and minimize the stochastic effect of ionizing radiation

  6. Consequences of major nuclear accidents on wild fauna and flora: dosimetric assessments remain a weakness to establish robust conclusions

    International Nuclear Information System (INIS)

    2014-01-01

    As about hundred of studies have been undertaken after the major nuclear accidents (Chernobyl and Fukushima) to study the consequences of these accidents on wild flora and fauna, notably on the effects of low doses of ionizing radiations, it appears that some of them reported noticeable effects due to extremely low doses. Such findings put knowledge in radiobiology into question again. This note aims at discussing the importance of the quality of dosimetric assessments for any study performed 'in natura'. It seems that the ambient external dose rate is not systematically a good indicator of the dose or dose rate absorbed by a living organism in radio-contaminated environment. This note outlines the problem related to the spatial heterogeneity of the radioactive contamination, that some statistic methods are not always adapted to data set quality. It briefly indicates other factors which may affect the quality of data set obtained during in situ studies

  7. Dosimetric essay in dental radiology; Experiencia dosimetrica en radiologia odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Salaberry, M [Ministerio de Industria, Energia y Mineria, Montevideo (Uruguay). Direccion Nacional de Tecnologia Nuclear; Dato Carfagna, A; Rodriguez Dorgia, R [Universidad de la Republica, Facultad de Odontologia , Montevideo (Uruguay)

    1999-12-31

    A neck study was observated in the tiroids glands,laryngeal zone, sensitive organs for the ionizing radiation for increase dental xray exams. Was selected 29th patients with radiography prescription complete (in the Odontology Faculty Clinics Uruguaian). It took radiographies with and without tiroids necklace and apron lead using dosemeters. Dosimetric studies had demonstrated good dose between patients. For measuring the radiation dose have been used TLD thermoluminescence dosimetric and Harshaw 6600 for read it. The thyroids necklace use and odontology postgrading for training course for dentistry was the two recommendations advised

  8. Radiometric and dosimetric characteristics of HgI2 detectors

    International Nuclear Information System (INIS)

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-01-01

    The characteristics of HgI 2 detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV

  9. Revision of the dosimetric parameters of the CSM11 LDR Cs-137 source.

    Science.gov (United States)

    Otal, Antonio; Martínez-Fernández, Juan Manuel; Granero, Domingo

    2011-03-01

    The clinical use of brachytherapy sources requires the existence of dosimetric data with enough of quality for the proper application of treatments in clinical practice. It has been found that the published data for the low dose rate CSM11 Cs-137 source lacks of smoothness in some regions because the data are too noisy. The purpose of this study was to calculate the dosimetric data for this source in order to provide quality dosimetric improvement of the existing dosimetric data of Ballester et al . [1]. In order to obtain the dose rate distributions Monte Carlo simulations were done using the GEANT4 code. A spherical phantom 40 cm in radius with the Cs-137 source located at the centre of the phantom was used. The results from Monte Carlo simulations were applied to derive AAPM Task Group 43 dosimetric parameters: anisotropy function, radial dose function, air kerma strength and dose rate constant. The dose rate constant obtained was 1.094 ± 0.002 cGy h -1 U -1 . The new calculated data agrees within experimental uncertainties with the existing data of Ballester et al . but without the statistical noise of that study. The obtained data presently fulfills all the requirements of the TG-43U1 update and thus it can be used in clinical practice.

  10. Characterization and standardization of a thermoluminescent dosimetric system to ultraviolet and laser radiation using CaSO4:Dy

    International Nuclear Information System (INIS)

    Grossi, Fabio Henrique

    2002-01-01

    The photo transferred thermoluminescence (PTTL) was used to characterize a dosimetric system to the laser and ultraviolet radiation. Dysprosium activated calcium sulphate samples (CaSO 4 :Dy) used are produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN) and have proved been an excellent dosimetric material for non ionizing radiation. PTTL signal was studied for UV radiation detection in the 220 to 450 nm range and for laser radiation in the 193 to 1.160 nm range. The samples presented more sensibility to the 193, 250, 310 and 337 nm wavelengths and no sensibility to infrared region. The samples presented linear PTTL in function of radiant exposure, excitation gamma dose in the range between 5 and 100 Gy and laser beam diameter between 2 and 6 nm. Another parameters studied were the angular dependence, UV lower exposure limit and PTTL signal optical fading. Spread laser radiation analysis was performed in the Ophthalmologic Department of Universidade Federal de Sao Paulo (UNIFESP) surgical center, showing that samples positioned as far as 4 m from laser source are sensitized to the laser radiation, as well as evaluating the laser exposure received by workers of medical area. A method to send the samples by mail was developed to the studies performed in the UNIFESP. (author)

  11. Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders

    International Nuclear Information System (INIS)

    Richardson, Susan; Palaniswaamy, Geethpriya; Grigsby, Perry W.

    2010-01-01

    Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction. The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm 3 (range, 0.01-1.32 cm 3 ). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.

  12. Fast neutron irradiation effects on CR-39 nuclear track detector for dosimetric applications

    International Nuclear Information System (INIS)

    Kader, M.H.

    2005-01-01

    The effect of neutron irradiation on the dosimetric properties of CR-39 solid-state nuclear track detector have been investigated. CR-39 samples were irradiated with neutrons of energies follow a Maxwellian distribution centered about 2 MeV. These samples were irradiated with different doses in the range 0.1-1 Sv. The background and track density were measured as a function of etching time. In addition, the dependence of sensitivity of CR-39 detector on the neutrons dose has been investigated. The results show that the Sensitivity started to increase at 0.4 Sv neutrons dose, so this sample were chosen to be a subject for further study to investigate the effect of gamma dose on its properties. The sample irradiated with 0.4 Sv were exposed to different doses of gamma rays at levels between 10 and 80 kGy. The effect of gamma doses on the bulk etching rate VB, the track diameter and the sensitivity of the CR-39 samples was investigated. The results show that the dosimetric properties of CR-39 SSNTD are greatly affected by both neutron and gamma irradiation

  13. Determination of Absorbed Dose Using a Dosimetric Film

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Badita, E.; Mitru, E.

    2009-01-01

    This paper presents the absorbed dose measurements by means of the irradiated dosimetric reference films. The dose distributions were made by MULTIDATA film densitometer using RTD-4 software, in INFLPR Linear Accelerator Department

  14. Use of a dosimetric system using a SMT phototransistor in the measurement for some dosimetric parameters in conventional radiotherapy

    International Nuclear Information System (INIS)

    Silva, J.O. da; Magalhaes, C.M.S. de; Santos, L.A.P.

    2008-01-01

    For monitoring the delivered dose in the patient undergoing a cancer treatment with high-energy ionizing radiation beams is necessary to use appropriate dosimeters for the beam control quality and if it is possible, to obtain the dose information during the treatment. For this, semiconductor-based devices are used because of their high spatial resolution and to be easy to handle in spite of the ionization chambers. Nowadays the bipolar phototransistors are being proposed as ionizing radiation detectors for presenting, beyond these characteristics, the signal amplification factor (gain). So, the aim of this work is to present the use of a dosimetric system using a SMT phototransistor in the measurement for some dosimetric parameters in conventional radiotherapy: the field factor and the off-axis ratio. The phototransistors readings were compared with ones obtained from a PTW 23343 Markus chamber, under the same conditions. (author)

  15. Internal dosimetric evaluation due to uranium aerosols

    International Nuclear Information System (INIS)

    Garcia Aguilar Juan; Delgado Avila Gustavo

    1991-01-01

    The present work has like object to carry out the internal dosimetric evaluation to the occupationally exposed personnel, due to the inhalation of aerosols of natural uranium and enriched in the pilot plant of nuclear fuel production of the National Institute of Nuclear Research

  16. Study of dosimetric properties of acetylsalicylic acid in pharmaceutical preparations by EPR spectroscopy

    International Nuclear Information System (INIS)

    Juarez Calderon, J.M.; Negron Mendoza, A.; Ramos Bernal, S.; Gomez Vidales, V.

    2008-01-01

    Electron paramagnetic resonance (EPR) was used to investigate the dosimetric properties of two pharmaceutical preparations containing acetylsalicylic acid, Aspirin (trademark) and Cafiaspirin (trademark). The EPR spectra of the irradiated samples were found to have an asymmetric absorption characterized by a major resonance at g = 2.0033. Dose response was investigated between dose ranges of 2 to 40 kGy for 60 Co-gamma rays. Fading characteristics and dependence on temperature irradiation were also studied. We suggest that commercial Aspirin (trademark) and Cafiaspirin (trademark) tablets can be used as dosimeters for industrial processes. (author)

  17. Integrated numerical platforms for environmental dose assessments of large tritium inventory facilities

    International Nuclear Information System (INIS)

    Castro, P.; Ardao, J.; Velarde, M.; Sedano, L.; Xiberta, J.

    2013-01-01

    Related with a prospected new scenario of large inventory tritium facilities [KATRIN at TLK, CANDUs, ITER, EAST, other coming] the prescribed dosimetric limits by ICRP-60 for tritium committed-doses are under discussion requiring, in parallel, to surmount the highly conservative assessments by increasing the refinement of dosimetric-assessments in many aspects. Precise Lagrangian-computations of dosimetric cloud-evolution after standardized (normal/incidental/SBO) tritium cloud emissions are today numerically open to the perfect match of real-time meteorological-data, and patterns data at diverse scales for prompt/early and chronic tritium dose assessments. The trends towards integrated-numerical-platforms for environmental-dose assessments of large tritium inventory facilities under development.

  18. CaSO4: Dy + Teflon dosimetric pellets for X, beta and gamma radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Lima, M.F.

    1987-08-01

    CaSO 4 : Dy + TEFLON dosimetric pellets with high sensitivity and low cost for X, beta and gamma radiation monitoring were studied and developed by the Dosimetric Material Production Laboratory of the Radiological Protection Departament and are disposable for sale. The thickness of the pellets are suitable for X, beta and gamma radiation measurements. The dosimetric properties of these pellets were determined and presented in this work. The results show the usefulness of 0,20mm thick pellets for beta radiation monitoring and 0,80mm thick pellets for x and gamma radiation detection. (Author) [pt

  19. Study of dosimetric systems-ferrous sulfate-ferric sulfate, glass slides and dyed aqueous solutions

    International Nuclear Information System (INIS)

    Fernandes, L.

    1979-01-01

    The effect of some variables which can effect the preparation of the ferrous sulfate used as dosimetric solution has been studied. Among these variables the purity of the water used for the preparation of the solution and the presence (or absence) of oxygen in the dosimetric solution were considered. The dose rate distribution according to the transverse and longitudinal sections of the Co 60 irradiator was studied experimentally, using the dosimetric solution, and theoretically, using a computer program (KIFE). The results obtained with the ferrous sulface dosimetric solution were used as reference for the study of the application of EM and MSG glass slide as a dosimetric system. For this purpose the effects of the weakening of the coloration induced in the glass by gamma rays (Co 60 ) and the relationship between the absorbed dose of radiation and the ratio between the variation in absorbation value and the thickness of the glass irradiated, were studied. A study was also made of the use of the dye indicators bromothymol-blue, methyl-orange, Congo-red, neutral-red and p-nitrophenol, in aqueous solution, for radiation dose measurements. The bleaching of each indicator solution, under gamma-radiation (Co 60 ) was studied in oxygen and nitrogen atmospheres.(Author) [pt

  20. Dosimetric monitoring in Ukraine - Present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2007-01-01

    Despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralised dose accounting system in Ukraine; existing dosimetry services operate obsolete manual thermoluminescence dosemeter (TLD) readers and do not meet modern proficiency standards. Currently, dosimetric monitoring is required for ∼42,000 occupationally exposed workers, including 9100 in medicine, 17,000 employees of nuclear power plants and ∼16,000 workers dealing with other sources of occupational exposure. This article presents the plan of elaboration of the United System for monitoring and registration of individual doses which has the aim of harmonisation of individual monitoring in Ukraine through securing methodical unity; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programmes; development and support of information infrastructure, in particular operation of the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. (authors)

  1. A new fully integrated X-ray irradiator system for dosimetric research

    International Nuclear Information System (INIS)

    Richter, D.; Mittelstraß, D.; Kreutzer, S.; Pintaske, R.; Dornich, K.; Fuchs, M.

    2016-01-01

    A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required. - Highlights: • Bench top X-ray irradiator provides variable dose-rates. • Simulation of low energy photon irradiation and hardening of X-ray. • Al-hardening for the irradiation of H_2O, BeO, Al_2O_3, quartz, feldspars and zircon. • Dosimetric dating equipment for luminescence and ESR.

  2. Operational guidance for radiation emergency response organisations in Europe for using bio-dosimetric tools developed in EU MULTIBIODOSE project

    International Nuclear Information System (INIS)

    Jaworska, Alicja; Ainsbury, Elizabeth A.; Rothkamm, Kai; Fattibene, Paola; Lindholm, Carita; Oestreicher, Ursula; Romm, Horst; Thierens, Hubert; Vral, Anne; Trompier, Francois; Voisin, Philippe; Woda, Clemens; Wojcik, Andrzej

    2015-01-01

    In the event of a large-scale radiological emergency, the triage of individuals according to their degree of exposure forms an important initial step of the accident management. Although clinical signs and symptoms of a serious exposure may be used for radiological triage, they are not necessarily radiation specific and can lead to a false diagnosis. Biodosimetry is a method based on the analysis of radiation-induced changes in cells of the human body or in portable electronic devices and enables the unequivocal identification of exposed people who should receive medical treatment. The MULTIBIODOSE (MBD) consortium developed and validated several bio-dosimetric assays and adapted and tested them as tools for biological dose assessment in a mass-casualty event. Different bio-dosimetric assays were validated against the 'gold standard' of biological dosimetry-the dicentric assay. The assays were harmonised in such a way that, in an emergency situation, they can be run in parallel in a network of European laboratories. The aim of this guidance is to give a concise overview of the developed bio-dosimetric tools as well as how and when they can be used in an emergency situation. (authors)

  3. Dosimetric control of radiotherapy treatments by Monte Carlo simulation of transmitted portal dose image

    International Nuclear Information System (INIS)

    Badel, Jean-Noel

    2009-01-01

    This research thesis addresses the dosimetric control of radiotherapy treatments by using amorphous silicon digital portal imagery. In a first part, the author reports the analysis of the dosimetric abilities of the imager (iViewGT) which is used in the radiotherapy department. The stability of the imager response on a short and on a long term has been studied. A relationship between the image grey level and the dose has been established for a reference irradiation field. The influence of irradiation parameters on the grey level variation with respect to the dose has been assessed. The obtained results show the possibility to use this system for dosimetry provided that a precise calibration is performed while taking the most influencing irradiation parameters into account, i.e. photon beam nominal energy, field size, and patient thickness. The author reports the development of a Monte Carlo simulation to model the imager response. It models the accelerator head by a generalized source point. Space and energy distributions of photons are calculated. This modelling can also be applied to the calculation of dose distribution within a patient, or to study physical interactions in the accelerator head. Then, the author explores a new approach to dose portal image prediction within the frame of an in vivo dosimetric control. He computes the image transmitted through the patient by Monte Carlo simulation, and measures the portal image of the irradiation field without the patient. Validation experiments are reported, and problems to be solved are highlighted (computation time, improvement of the collimator simulation) [fr

  4. ESR dosimetric properties of some biomineral materials

    International Nuclear Information System (INIS)

    Hassan, Gamal M.; Sharaf, M.A.

    2005-01-01

    Dosimetric properties of g-irradiated modern coral and bioactive glass (Bio-G) samples analyzed with electron spin resonance (ESR) have been separately reported (Hassan et al., 2004; Sharaf and Hassan, 2004) and compared with alanine. These are combined here to allow a three-way comparison between these materials

  5. ESR dosimetric properties of some biomineral materials

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Gamal M. [Department of Ionizing Radiation Metrology, National Institute for Standards (NIS), Tersa Street, El-Haram, El-Giza, P.O. Box 136 Giza, El-Giza (Egypt)]. E-mail: gamalhassan65@hotmail.com; Sharaf, M.A. [Department of Ionizing Radiation Metrology, National Institute for Standards (NIS), Tersa Street, El-Haram, El-Giza, P.O. Box 136 Giza, El-Giza (Egypt)

    2005-02-01

    Dosimetric properties of g-irradiated modern coral and bioactive glass (Bio-G) samples analyzed with electron spin resonance (ESR) have been separately reported (Hassan et al., 2004; Sharaf and Hassan, 2004) and compared with alanine. These are combined here to allow a three-way comparison between these materials.

  6. Researches and Applications of ESR Dosimetry for Radiation Accident Dose Assessment

    International Nuclear Information System (INIS)

    Wu, K.; Guo, L.; Cong, J.B.; Sun, C.P.; Hu, J.M.; Zhou, Z.S.; Wang, S.; Zhang, Y.; Zhang, X.; Shi, Y.M.

    1998-01-01

    The aim of this work was to establish methods suitable for practical dose assessment of people involved in ionising radiation accidents. Some biological materials of the human body and materials possibly carried or worn by people were taken as detection samples. By using electron spin resonance (ESR) techniques, the basic dosimetric properties of selected materials were investigated in the range above the threshold dose of human acute haemopoietic radiation syndrome. The dosimetric properties involved included dose response properties of ESR signals, signal stabilities, distribution of background signals, the lowest detectable dose value, radiation conditions, environmental effects on the detecting process, etc. Several practical dose analytical indexes and detecting methods were set up. Some of them (bone, watch glass and tooth enamel) had also been successfully used in the dose assessment of people involved in three radiation accidents, including the Chernobyl reactor accident. This work further proves the important role of ESR techniques in radiation accident dose estimation. (author)

  7. In-vivo dosimetric study of carcinoma of uterine cervix with FBX solution in external beam therapy

    International Nuclear Information System (INIS)

    Srinivas, Challapalli; Shenoy, K. Kamalaksh; Dinesh, M.; Savitha, K.S.; Kasturi, Dinesh Pai; Supe, S.S.; Nagesha, Y.N.

    1999-01-01

    To ensure accurate dose delivery to target site in external beam therapy and brachytherapy, various authors have conducted tests to assess the process of manual dose calculations. In vivo dosimetric measurement is one of these methods to verify these calculations. In this study, an attempt has been made to compare the manually calculated dose to dose estimated using a chemical dosimeter (FBX) solution (in-vivo method, using polypropylene vials), on 12 patients of carcinoma of uterine cervix in external beam therapy. Dose measured by FBX vial varies in the range of ± 2 to 6.75%, as compared with manual calculations. These variations seen may be attributed to the location of the vial position in the vagina, with reference to the beam axis (may not be horizontal), off axis position, manual calculation variations and reproducibility of the FBX system etc. FBX dosimetry offers itself as an in-vivo method to estimate the dose delivered to the target site in external beam therapy. (author)

  8. Dosimetric approaches: pregnancy and lactation

    International Nuclear Information System (INIS)

    Rojo, Ana M.

    2001-01-01

    The female nuclear medicine patient is of special concern to the evaluation of radiation dose since radiation protection point of view: a)- The females overall body size and organ sizes are generally smaller than those of her male counterpart (thus her radiation doses will be higher, given the same amounts of administered activity and similar biokinetics), the effective doses could be 25 per cent higher than a man; b)- Female gonads are inside the body instead of outside and are near several organs often important as source organs in internal dosimetry; female gonads doses could be up to 10 or 30 higher than male gonads (usually 3 order); c)- Risk of breast cancer is significantly higher among females than males; d)- During the pregnancy due to placental transfer of radiopharmaceuticals or radiation exposure from the urinary bladder the embryo/fetus could receive doses that must be avoid; e)- In the case of nursing infant is of special concern in such an analysis to determine the interruption period to avoid doses in the nursing infant. The dosimetric approaches to take account to assess internal doses in the pregnant woman and during the breast feeding are discussed. (author)

  9. Geometric factors influencing dosimetric sparing of the parotid glands using IMRT

    International Nuclear Information System (INIS)

    Hunt, Margie A.; Jackson, Andrew; Narayana, Ashwatha; Lee, Nancy

    2006-01-01

    Purpose/Objective: To determine the relationship between the parotid volume, parotid-planning target volume (PTV) overlap, and dosimetric sparing of the parotid with intensity-modulated radiation therapy (IMRT). Methods and Materials: Parotid data were collected retrospectively for 51 patients treated with simultaneous boost IMRT. Unresectable patients received 54 or 59.4 Gy to subclinical disease, 70 Gy to gross disease. Patients treated postoperatively received 54, 60, and 66 Gy to low-risk, high-risk, and tumor bed regions. Volume and mean dose of each gland and gland segments outside of and overlapping the PTV were collected. Proximity of each gland to each PTV was recorded. Results: Dosimetric sparing (mean dose ≤26.5 Gy) was achieved in 66 of 71 glands with ≤21% parotid-PTV overlap and 8 of 23 glands with >21% overlap (p = 21%. Median mean dose was 25.9 Gy to glands overlapping PTV 54 or PTV 59 alone and 30.0 Gy to those abutting PTV 7 (p 7 was associated with higher parotid dose, satisfactory sparing was achieved in 24 of 43 ipsilateral glands. Conclusions: Dosimetric sparing of the parotid is feasible when the parotid-PTV overlap is less than approximately 20%. With more overlap, sparing may result in low doses within the overlap region, possibly leading to inadequate PTV coverage. Gland proximity to the high-dose PTV is associated with higher mean dose but does not always preclude dosimetric sparing

  10. Dosimetric considerations in radioimmunotherapy of patients with hepatoma

    International Nuclear Information System (INIS)

    Leichner, P.K.; Klein, J.L.; Order, S.E.

    1986-01-01

    Dosimetric studies of I-131 labeled antiferritin have provided the foundation for preparative and administrative aspects of radiolabeled antibody treatment of patients with hepatoma. Tumor response to I-131 labeled antiferritin IgG was encouraging and radioimmunotherapy with Y-90 labeled antiferritin IgG was recently initiated. For these patients, In-111 labeled antiferritin IgG was used as the imaging agent, with administered activities ranging from 0.8 - 7 mCi. Serial gamma camera imaging from 30 minutes to 6 days post injection demonstrated that 5-30% of the administered activity localized in hepatomas (8/12 patients). The mean value of the effective half-life in the tumor and liver was 2.8 d. Disappearance curves for the blood circulation, spleen, and other normal tissues were biphasic such that 50% of the activity disappeared within 24 hours post injection. The eight patients who demonstrated sufficient tumor localization where subsequently treated with Y-90 labeled antiferritin IgG. Administered activities were dependent on tumor volume and uptake of radiolabeled IgG and ranged from 8 - 20 mCi. The remaining patients were treated under other existing protocols. 10 references

  11. Dosimetric properties of bio minerals applied to high-dose dosimetry using the TSEE technique

    International Nuclear Information System (INIS)

    Vila, G. B.; Caldas, L. V. E.

    2014-08-01

    The study of the dosimetric properties such as reproducibility, the residual signal, lower detection dose, dose-response curve and fading of the thermally stimulated emission exo electronic (TSEE) signal of Brazilian bio minerals has shown that these materials present a potential use as radiation dosimeters. The reproducibility within ± 10% for oyster shell, mother-of-pearl and coral reef samples showed that the signal dispersion is small when compared with the mean value of the measurements. The study showed that the residual signal can be eliminated with a thermal treatment at 300 grades C/1 h. The lower detection dose of 9.8 Gy determined for the oyster shell samples when exposed to beta radiation and 1.6 Gy for oyster shell and mother-of-pearl samples when exposed to gamma radiation can be considered good, taking into account the high doses of this study. The materials presented linearity at the dose response curves in some ranges, but the lack of linearity in other cases presents no problem since a good mathematical description is possible. The fading study showed that the loss of TSEE signal can be minimized if the samples are protected from interferences such as light, heat and humidity. Taking into account the useful linearity range as the main dosimetric characteristic, the tiger shell and oyster shell samples are the most suitable for high-dose dosimetry using the TSEE technique. (Author)

  12. Dosimetric properties of bio minerals applied to high-dose dosimetry using the TSEE technique

    Energy Technology Data Exchange (ETDEWEB)

    Vila, G. B.; Caldas, L. V. E., E-mail: gbvila@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The study of the dosimetric properties such as reproducibility, the residual signal, lower detection dose, dose-response curve and fading of the thermally stimulated emission exo electronic (TSEE) signal of Brazilian bio minerals has shown that these materials present a potential use as radiation dosimeters. The reproducibility within ± 10% for oyster shell, mother-of-pearl and coral reef samples showed that the signal dispersion is small when compared with the mean value of the measurements. The study showed that the residual signal can be eliminated with a thermal treatment at 300 grades C/1 h. The lower detection dose of 9.8 Gy determined for the oyster shell samples when exposed to beta radiation and 1.6 Gy for oyster shell and mother-of-pearl samples when exposed to gamma radiation can be considered good, taking into account the high doses of this study. The materials presented linearity at the dose response curves in some ranges, but the lack of linearity in other cases presents no problem since a good mathematical description is possible. The fading study showed that the loss of TSEE signal can be minimized if the samples are protected from interferences such as light, heat and humidity. Taking into account the useful linearity range as the main dosimetric characteristic, the tiger shell and oyster shell samples are the most suitable for high-dose dosimetry using the TSEE technique. (Author)

  13. Dosimetric Consequences of Interobserver Variability in Delineating the Organs at Risk in Gynecologic Interstitial Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Damato, Antonio L., E-mail: adamato@lroc.harvard.edu [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States); Townamchai, Kanopkis [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States); Albert, Michele [Department of Radiation Oncology, Saint Anne' s Hospital Regional Cancer Center, Fall River, Massachusetts (United States); Bair, Ryan J. [Department of Radiology, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Cormack, Robert A. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States); Jang, Joanne [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts (United States); Kovacs, Arpad [Department of Radiology, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Lee, Larissa J. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States); Mak, Kimberley S.; Mirabeau-Beale, Kristina L.; Mouw, Kent W.; Phillips, John G.; Pretz, Jennifer L.; Russo, Andrea L. [Harvard Radiation Oncology Program, Harvard Medical School, Boston, Massachusetts (United States); Lewis, John H.; Viswanathan, Akila N. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2014-07-01

    Purpose: To investigate the dosimetric variability associated with interobserver organ-at-risk delineation differences on computed tomography in patients undergoing gynecologic interstitial brachytherapy. Methods and Materials: The rectum, bladder, and sigmoid of 14 patients treated with gynecologic interstitial brachytherapy were retrospectively contoured by 13 physicians. Geometric variability was calculated using κ statistics, conformity index (CI{sub gen}), and coefficient of variation (CV) of volumes contoured across physicians. Dosimetric variability of the single-fraction D{sub 0.1cc} and D{sub 2cc} was assessed through CV across physicians, and the standard deviation of the total EQD2 (equivalent dose in 2 Gy per fraction) brachytherapy dose (SD{sup TOT}) was calculated. Results: The population mean ± 1 standard deviation of κ, CI{sub gen}, and volume CV were, respectively: 0.77 ± 0.06, 0.70 ± 0.08, and 20% ± 6% for bladder; 0.74 ± 06, 0.67 ± 0.08, and 20% ± 5% for rectum; and 0.33 ± 0.20, 0.26 ± 0.17, and 82% ± 42% for sigmoid. Dosimetric variability was as follows: for bladder, CV = 31% ± 19% (SD{sup TOT} = 72 ± 64 Gy) for D{sub 0.1cc} and CV = 16% ± 10% (SD{sup TOT} = 9 ± 6 Gy) for D{sub 2cc}; for rectum, CV = 11% ± 5% (SD{sup TOT} = 16 ± 17 Gy) for D{sub 0.1cc} and CV = 7% ± 2% (SD{sup TOT} = 4 ± 3 Gy) for D{sub 2cc}; for sigmoid, CV = 39% ± 28% (SD{sup TOT} = 12 ± 18 Gy) for D{sub 0.1cc} and CV = 34% ± 19% (SD{sup TOT} = 4 ± 4 Gy) for D{sub 2cc.} Conclusions: Delineation of bladder and rectum by 13 physicians demonstrated substantial geometric agreement and resulted in good dosimetric agreement for all dose-volume histogram parameters except bladder D{sub 0.1cc.} Small delineation differences in high-dose regions by the posterior bladder wall may explain these results. The delineation of sigmoid showed fair geometric agreement. The higher dosimetric variability for sigmoid compared with rectum and bladder did not correlate with

  14. Automatic 2D scintillation camera and computed tomography whole-body image registration to perform dosimetric calculations

    International Nuclear Information System (INIS)

    Cismondi, F.; Mosconi, S.L.

    2008-01-01

    Full text: In this work a software tool that has been developed to allow automatic registrations of 2D Scintillation Camera (SC) and Computed Tomography (CT) images is presented. This tool, used with a dosimetric software with Integrated Activity or Residence Time as input data, allows the user to assess physicians about effects of radiodiagnostic or radiotherapeutic practices that involves nuclear medicine 'open sources'. Images are registered locally and globally, maximizing Mutual Information coefficient between regions been registered. In the regional case whole-body images are segmented into five regions: head, thorax, pelvis, left and right legs. Each region has its own registration parameters, which are optimized through Powell-Brent minimization method that 'maximizes' Mutual Information coefficient. This software tool allows the user to draw ROIs, input isotope characteristics and finally calculate Integrated Activity or Residence Time in one or many specific organ. These last values can be introduced in many dosimetric software to finally obtain Absorbed Dose values. (author)

  15. Dosimetric properties of Li2 B4 O7: Tm pellets

    International Nuclear Information System (INIS)

    Rzyski, B.M.; Morato, S.P.

    1987-10-01

    Pellets produced out of thulium doped lithium tetraborate, (Li 2 B 4 O 7 :Tm), for thermoluminescent, (TL), dosimetry present low sensibility to environment conditions. Humidity, ambiet temperature, fading and handling during TL reading have almost no influence on the TL properties of the pellets prepared according the receipt given in this paper. The structure of the TL glow curve for the irradiated Li 2 B 4 O 7 : Tm pellet is rather simple and the TL response is linear in the range of 3x10 -4 to 7x10 2 Gy. The dosimetric properties of Li 2 B 4 O 7 : Tm in pellet form makes it a competitor with other TL phosphors. (author) [pt

  16. Dosimetric evaluation of a MOSFET detector for clinical application in photon therapy.

    Science.gov (United States)

    Kohno, Ryosuke; Hirano, Eriko; Nishio, Teiji; Miyagishi, Tomoko; Goka, Tomonori; Kawashima, Mitsuhiko; Ogino, Takashi

    2008-01-01

    Dosimetric characteristics of a metal oxide-silicon semiconductor field effect transistor (MOSFET) detector are studied with megavoltage photon beams for patient dose verification. The major advantages of this detector are its size, which makes it a point dosimeter, and its ease of use. In order to use the MOSFET detector for dose verification of intensity-modulated radiation therapy (IMRT) and in-vivo dosimetry for radiation therapy, we need to evaluate the dosimetric properties of the MOSFET detector. Therefore, we investigated the reproducibility, dose-rate effect, accumulated-dose effect, angular dependence, and accuracy in tissue-maximum ratio measurements. Then, as it takes about 20 min in actual IMRT for the patient, we evaluated fading effect of MOSFET response. When the MOSFETs were read-out 20 min after irradiation, we observed a fading effect of 0.9% with 0.9% standard error of the mean. Further, we applied the MOSFET to the measurement of small field total scatter factor. The MOSFET for dose measurements of small field sizes was better than the reference pinpoint chamber with vertical direction. In conclusion, we assessed the accuracy, reliability, and usefulness of the MOSFET detector in clinical applications such as pinpoint absolute dosimetry for small fields.

  17. Dosimetric Comparison of Helical Tomotherapy and Dynamic Conformal Arc Therapy in Stereotactic Radiosurgery for Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Lee, Tsair-Fwu; Chao, Pei-Ju; Wang, Chang-Yu; Lan, Jen-Hong; Huang, Yu-Je; Hsu, Hsuan-Chih; Sung, Chieh-Cheng; Su, Te-Jen; Lian, Shi-Long; Fang, Fu-Min

    2011-01-01

    The dosimetric results of stereotactic radiosurgery (SRS) for vestibular schwannoma (VS) performed using dynamic conformal arc therapy (DCAT) with the Novalis system and helical TomoTherapy (HT) were compared using plan quality indices. The HT plans were created for 10 consecutive patients with VS previously treated with SRS using the Novalis system. The dosimetric indices used to compare the techniques included the conformity index (CI) and homogeneity index (HI) for the planned target volume (PTV), the comprehensive quality index (CQI) for nine organs at risk (OARs), gradient score index (GSI) for the dose drop-off outside the PTV, and plan quality index (PQI), which was verified using the plan quality discerning power (PQDP) to incorporate 3 plan indices, to evaluate the rival plans. The PTV ranged from 0.27-19.99 cm 3 (median 3.39 cm 3 ), with minimum required PTV prescribed doses of 10-16 Gy (median 12 Gy). Both systems satisfied the minimum required PTV prescription doses. HT conformed better to the PTV (CI: 1.51 ± 0.23 vs. 1.94 ± 0.34; p < 0.01), but had a worse drop-off outside the PTV (GSI: 40.3 ± 10.9 vs. 64.9 ± 13.6; p < 0.01) compared with DCAT. No significant difference in PTV homogeneity was observed (HI: 1.08 ± 0.03 vs. 1.09 ± 0.02; p = 0.20). HT had a significantly lower maximum dose in 4 OARs and significant lower mean dose in 1 OAR; by contrast, DCAT had a significantly lower maximum dose in 1 OAR and significant lower mean dose in 2 OARs, with the CQI of the 9 OARs = 0.92 ± 0.45. Plan analysis using PQI (HT 0.37 ± 0.12 vs. DCAT 0.65 ± 0.08; p < 0.01), and verified using the PQDP, confirmed the dosimetric advantage of HT. However, the HT system had a longer beam-on time (33.2 ± 7.4 vs. 4.6 ± 0.9 min; p < 0.01) and consumed more monitor units (16772 ± 3803 vs. 1776 ± 356.3; p < 0.01). HT had a better dose conformity and similar dose homogeneity but worse dose gradient than DCAT. Plan analysis confirmed the dosimetric advantage of HT

  18. Study of dosimetric properties of acetylsalicylic acid in pharmaceutical preparations by EPR spectroscopy

    International Nuclear Information System (INIS)

    Juarez-Calderon, J.M.; Negron-Mendoza, A.; Ramos-Bernal, S.; Gomez-Vidales, V.

    2009-01-01

    Electron paramagnetic resonance (EPR) was used to investigate the dosimetric properties of two pharmaceutical preparations containing acetylsalicylic acid, Aspirin R and Cafiaspirin R . The EPR spectra of the irradiated samples were found to have an asymmetric absorption characterized by a major resonance at g = 2.0033. Dose response was investigated between dose ranges of 2 to 95 kGy for 60 Co-gamma rays. Fading characteristics and dependence on temperature irradiation were also studied. We suggest that commercial Aspirin R and Cafiaspirin R tablets can be used as dosimeters in the case of a short accident. (author)

  19. Dosimetric comparison of intensity modulated radiosurgery with dynamic conformal arc radiosurgery for small cranial lesions

    Directory of Open Access Journals (Sweden)

    Juan F Calvo-Ortega

    2016-01-01

    Conclusions: We have shown that IMRS provides the dosimetric advantages compared with DCARS. Based on the dosimetric findings in this study, fixed gantry IMRS technique can be adopted as a standard procedure for cranial SRS when micro-MLC technology is not available on the linear accelerator.

  20. Thermoluminescence dosimetric characteristics of thulium doped ZnB2O4 phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Madhusoodanan, U.; Subramanian, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of rare earth doped Zinc borates were synthesized by high temperature solid state diffusion technique. Dosimetric characteristics of the phosphor like thermoluminescence glow curve, TL emission spectra, dose–response, fading studies, reproducibility and reusability studies were carried out on the synthesized phosphors. Among the different rare earth doped phosphors, thulium doped zinc borate was found to have a higher sensitivity. Hence detailed dosimetric characteristics of this phosphor were carried out. It is observed that the dose–response is linear from 10 mGy to 10 3 Gy in this phosphor. EPR measurements were carried out on unirradiated, gamma irradiated and annealed phosphors to identify the defect centers responsible for thermoluminescence. A TL model is proposed based on the EPR studies in these materials. Kinetic parameters were evaluated for the dosimetric peaks using various methods. The experimental results show that this phosphor can have potential applications in radiation dosimetry applications. -- Highlights: • Polycrystalline powder samples of rare earth doped zinc borates were synthesized. • Thulium was observed to be the most efficient dopant in ZnB 2 O 4 lattice. • TL intensity of the dosimetric peak is around 20 times that of TLD-100. • Based on EPR studies a TL mechanism is proposed in zinc borate. • Deconvolution of the glow curve carried out

  1. Dosimetric characterization of a bi-directional micromultileaf collimator for stereotactic applications.

    Science.gov (United States)

    Bucciolini, M; Russo, S; Banci Buonamici, F; Pini, S; Silli, P

    2002-07-01

    A 6 MV photon beam from Linac SL75-5 has been collimated with a new micromultileaf device that is able to shape the field in the two orthogonal directions with four banks of leaves. This is the first clinical installation of the collimator and in this paper the dosimetric characterization of the system is reported. The dosimetric parameters required by the treatment planning system used for the dose calculation in the patient are: tissue maximum ratios, output factors, transmission and leakage of the leaves, penumbra values. Ionization chambers, silicon diode, radiographic films, and LiF thermoluminescent dosimeters have been employed for measurements of absolute dose and beam dosimetric data. Measurements with different dosimeters supply results in reasonable agreement among them and consistent with data available in literature for other models of micromultileaf collimator; that permits the use of the measured parameters for clinical applications. The discrepancies between results obtained with the different detectors (around 2%) for the analyzed parameters can be considered an indication of the accuracy that can be reached by current stereotactic dosimetry.

  2. Dosimetric study for characterization of a postal system of quality control in brachytherapy

    International Nuclear Information System (INIS)

    Alves, Victor Gabriel Leandro; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza; Begalli, Marcia

    2009-01-01

    This work presents a dosimetric study of a postal system, to be developed for measurements of brachytherapy. It was projected a PMMA phantom with orifices for insertion of the high dose 192 Ir source and the T L dosemeters. The system was characterized with using of Monte Carlo simulations, using the dosimetric magnitudes defined at the T G-43 of AAPM, as function of radial dose g(f)

  3. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    Science.gov (United States)

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV.

  4. Researches, development and characterization of dosimetric materials for monitoring in irradiation processes with high doses; Pesquisa, desenvolvimento e caracterizacao de materiais dosimetricos para monitoramento em processos de irradiacao com doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Galante, Ana Maria Sisti

    2003-07-01

    Dosimetric materials that can be produced in Brazil with material acquired in the national market to replace the imported dosimeters used in radiation processing were developed in this work. Mixtures of potassium nitrate and sensitizers compounds as manganese dioxide, barium nitrate and potassium bromide were prepared in the pellet form. Dosimetric characteristics such as dose-response useful range, sensitivity, environmental conditions and dose rate influences were evaluated in {sup 60}Co gamma radiation fields. Dyed polymethylmethacrylate detectors were also produced and its dosimetric characteristics were evaluated. The main characteristics evaluated in this case were: dose response useful range sensitivity, environmental conditions, dose rate influences and radiation energy dependence in gamma radiation fields and accelerated electrons beam of 0.8 to 1.5 MeV. The applied analytic technique was spectrophotometry. The calibration was performed in the irradiation facilities belonging to IPEN and certified by the International Atomic Energy Agency by means of the program IDAS (International Dose Assurance Service ) using the Fricke dosimeter. The mixture of potassium nitrate and manganese dioxide presented the best results and a wide dose range between 200 and 600 kGy. The response of the developed polymethylmethacrylate detectors are similar to the imported detectors and the dose range is characteristic to each detector and depends on the dye added in its formulation. (author)

  5. Dosimetric and clinical results of three-dimensional conformal radiotherapy for locally recurrent nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zheng Xiaokang; Ma Jun; Chen Longhua; Xia Yunfei; Shi Yusheng

    2005-01-01

    Purpose: To assess the dosimetric and clinical results of three-dimensional conformal radiotherapy (3D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: A total of 86 patients with locally recurrent NPC were retreated with 3D CRT. The median prescribed dose was 68 Gy with 2 Gy per fractionation. Dosimetric quality was evaluated with dose distribution in planning target volume (PTV) and specified organs at risk (OAR), dose conformity index (CI) and dose homogeneity index (HI). The actuarial rate of local failure-free (LFF), overall survival (OS) and major late toxicities (MLT) were estimated with Kaplan-Meier method. Multivariate analysis for prognosis was performed using the Cox regression proportional hazards model. Results: The mean dose to PTV averaged 66.8 Gy, and the dose to specified OAR was acceptable. The average value of CI and HI was 0.59 and 9.1%. The 5-year actuarial rate of LFF and OS was 71 and 40%, respectively. The 5-year actuarial incidence of MLT≥Grade 3 and ≥Grade 4 were 100 and 49%, respectively. The major prognostic factors were T stage and the size of gross tumor volume (GTV). Advanced T stage and large GTV volume were associated with poor LFF and OS and high risk of MLT. Conclusion: The dosimetric quality of 3D CRT for locally recurrent NPC is generally excellent. A relatively high local control was achieved with this technique. However, the incidence of late toxicities were not found to decrease as originally expected. Early diagnosis of the recurrence and reasonable definition of the target volume are crucial to achieve a better outcome

  6. Dosimetric model for antibody targeted radionuclide therapy of tumor cells in cerebrospinal fluid

    International Nuclear Information System (INIS)

    Millar, W.T.; Barrett, A.

    1990-01-01

    Although encouraging results have been obtained using systemic radioimmunotherapy in the treatment of cancer, it is likely that regional applications may prove more effective. One such strategy is the treatment of central nervous system leukemia in children by intrathecal instillation of targeting or nontargeting beta particle emitting radionuclide carriers. The beta particle dosimetry of the spine is assessed, assuming that the spinal cord and the cerebrospinal fluid compartment can be adequately represented by a cylindrical annulus. The radionuclides investigated were 90 Y, 131 I, 67 Cu, and 199 Au. It is shown that the radiation dose to the cord can be significantly reduced using short range beta particle emitters and that there is little advantage in using targeting carriers with these radionuclides. 199 Au and 67 Cu also have the advantage of having a suitable gamma emission for imaging, permitting pretherapy imaging and dosimetric calculations to be undertaken prior to therapy. If these methods prove successful, it may be possible to replace the external beam component used in the treatment of central nervous system leukemia in children by intrathecal radionuclide therapy, thus reducing or avoiding side effects such as growth and intellectual impairment

  7. Dosimetric considerations and radiation protection of patients in interventional cardiology

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Arandjic, D.; Kosutic, D.; Loncar, B.

    2009-01-01

    The paper summarizes results of measurements of relevant dosimetric quantities in interventional cardiology. Dosimetric data were collected for 117 coronary angiography (CA) procedures, 69 percutaneous coronary interventions (PCI) and 41 combined procedures (CA+PCI), taking into account two quantities: air kerma area product (KAP) d air kerma in international reference point (K IRP ). Mean KAP values were 78 Gy·cm 2 , 113 Gy·cm 2 and 141 Gy·cm 2 for CA, PCI i CA+PCI, respectively. Corresponding mean K IRP values were 1.2 Gy, 1.8 Gy and 2.2 Gy. With respect to high dose values, risk for stochastic effects and tissue reactions, dose management methods were proposed. (author) [sr

  8. Potential benefits of dosimetric VMAT tracking verified with 3D film measurements

    Energy Technology Data Exchange (ETDEWEB)

    Crijns, Wouter, E-mail: wouter.crijns@uzleuven.be; Depuydt, Tom; Haustermans, Karin [Laboratory of Experimental Radiotherapy, KU Leuven Department of Oncology, Herestraat 49, 3000 Leuven (Belgium); Radiation Oncology, University Hospitals Leuven, Herestraat 49, 3000 Leuven (Belgium); Defraene, Gilles [Laboratory of Experimental Radiotherapy, KU Leuven Department of Oncology, Herestraat 49, 3000 Leuven, Belgium and KU Leuven Medical Imaging Research Center, Herestraat 49, 3000 Leuven (Belgium); Van Herck, Hans [KU Leuven Medical Imaging Research Center, Herestraat 49, 3000 Leuven, Belgium and KU Leuven Department of Electrical Engineering (ESAT)–PSI, Center for Processing Speech and Images, 3000 Leuven (Belgium); Maes, Frederik [KU Leuven Medical Imaging Research Center, Herestraat 49, 3000 Leuven (Belgium); KU Leuven Department of Electrical Engineering (ESAT)–PSI, Center for Processing Speech and Images, 3000 Leuven (Belgium); Medical IT Department, KU Leuven iMinds, 3000 Leuven (Belgium); Van den Heuvel, Frank [Department of Oncology, MRC-CR-UK Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford OX1 2JD (United Kingdom)

    2016-05-15

    Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously

  9. Dosimetric measurements of an n-butyl cyanoacrylate embolization material for arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Labby, Zacariah E., E-mail: zelabby@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin–Madison, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Chaudhary, Neeraj [Division of Neurointerventional Radiology, Departments of Radiology and Neurosurgery, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Gemmete, Joseph J. [Division of Neurointerventional Radiology, Departments of Radiology, Neurosurgery, and Otolaryngology, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Pandey, Aditya S. [Department of Neurosurgery, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Roberts, Donald A. [Radiation Physics Division, Department of Radiation Oncology, University of Michigan Hospital and Health Systems, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States)

    2015-04-15

    Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derived from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner’s HU calibration curve. Results: The ELAC was 0.0516 ± 0.0063 cm{sup −1} and 0.0580 ± 0.0091 cm{sup −1} for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm{sup −1} for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of −0.29% and −0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively

  10. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  11. Radiation sensitivity and EPR dosimetric potential of gallic acid and its esters

    Science.gov (United States)

    Tuner, Hasan; Oktay Bal, M.; Polat, Mustafa

    2015-02-01

    In the preset work the radiation sensitivities of Gallic Acid anhydrous and monohydrate, Octyl, Lauryl, and Ethyl Gallate (GA, GAm, OG, LG, and EG) were investigated in the intermediate (0.5-20 kGy) and low radiation (<10 Gy) dose range using Electron Paramagnetic Resonance (EPR) spectroscopy. While OG, LG, and EG are presented a singlet EPR spectra, their radiation sensitivity found to be very different in the intermediate dose range. At low radiation dose range (<10 Gy) only LG is found to be present a signal that easily distinguished from the noise signals. The intermediate and low dose range radiation sensitivities are compared using well known EPR dosimeter alanine. The radiation yields (G) of the interested material were found to be 1.34×10-2, 1.48×10-2, 4.14×10-2, and 6.03×10-2, 9.44×10-2 for EG, GA, GAm, OG, and LG, respectively at the intermediate dose range. It is found that the simple EPR spectra and the noticeable EPR signal of LG make it a promising dosimetric material to be used below 10 Gy of radiation dose.

  12. Equine scintigraphy: assessment of the dose received by the personnel; Scintigraphie equine: estimation de la dose recue par le personnel

    Energy Technology Data Exchange (ETDEWEB)

    Clairand, I.; Bottollier, J.F.; Trompier, F. [Institut de Radioprotection et de Surete Nucleaire IRSN, 92 - Fontenay aux Roses (France)

    2003-03-01

    Following a request from the Permanent Secretary of the French Commission for Artificial Radioelements (CIREA) engaged to investigate a request for a licence related to a new scintigraphy unit dedicated to equidae, a dosimetric assessment concerning the personnel attending the examination was carried out. This scintigraphy unit depends on the Goustranville Centre for Imaging and Research on the Locomotive Diseases of Equidae (CIRALE) in the Calvados region. The dosimetric assessment was carried out for the different operators during the successive stages of the scintigraphic examination. Assuming 150 examinations per year, the annual equivalent dose to the fingers skin is 150 mSv maximum for the technologist and 2 mSv for the veterinary surgeon; the annual effective dose ranges from 0.15 to 0.45 mSv, depending on the operators. (authors)

  13. Dosimetric adaptive IMRT driven by fiducial points

    International Nuclear Information System (INIS)

    Crijns, Wouter; Van Herck, Hans; Defraene, Gilles; Van den Bergh, Laura; Haustermans, Karin; Slagmolen, Pieter; Maes, Frederik; Van den Heuvel, Frank

    2014-01-01

    Purpose: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy have become standard treatments but are more sensitive to anatomical variations than 3D conformal techniques. To correct for inter- and intrafraction anatomical variations, fast and easy to implement methods are needed. Here, the authors propose a full dosimetric IMRT correction that finds a compromise in-between basic repositioning (the current clinical practice) and full replanning. It simplifies replanning by avoiding a recontouring step and a full dose calculation. It surpasses repositioning by updating the preoptimized fluence and monitor units (MU) using a limited number of fiducial points and a pretreatment (CB)CT. To adapt the fluence the fiducial points were projected in the beam's eye view (BEV). To adapt the MUs, point dose calculation towards the same fiducial points were performed. The proposed method is intrinsically fast and robust, and simple to understand for operators, because of the use of only four fiducial points and the beam data based point dose calculations. Methods: To perform our dosimetric adaptation, two fluence corrections in the BEV are combined with two MU correction steps along the beam's path. (1) A transformation of the fluence map such that it is realigned with the current target geometry. (2) A correction for an unintended scaling of the penumbra margin when the treatment beams scale to the current target size. (3) A correction for the target depth relative to the body contour and (4) a correction for the target distance to the source. The impact of the correction strategy and its individual components was evaluated by simulations on a virtual prostate phantom. This heterogeneous reference phantom was systematically subjected to population based prostate transformations to simulate interfraction variations. Additionally, a patient example illustrated the clinical practice. The correction strategy was evaluated using both dosimetric

  14. Dosimetric adaptive IMRT driven by fiducial points

    Energy Technology Data Exchange (ETDEWEB)

    Crijns, Wouter, E-mail: wouter.crijns@uzleuven.be [Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Herestraat 49, 3000 Leuven, Belgium and Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Van Herck, Hans [Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven, Belgium and Department of Electrical Engineering (ESAT) – PSI, Center for the Processing of Speech and Images, KU Leuven, 3000 Leuven (Belgium); Defraene, Gilles; Van den Bergh, Laura; Haustermans, Karin [Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Slagmolen, Pieter [Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Department of Electrical Engineering (ESAT) – PSI, Center for the Processing of Speech and Images, KU Leuven, 3000 Leuven (Belgium); iMinds-KU Leuven Medical IT Department, KU Leuven, 3000 Leuven (Belgium); Maes, Frederik [Medical Imaging Research Center, KU Leuven, Herestraat 49, 3000 Leuven (Belgium); Department of Electrical Engineering (ESAT) – PSI, Center for the Processing of Speech and Images, KU Leuven and iMinds, 3000 Leuven (Belgium); Van den Heuvel, Frank [Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Herestraat 49, 3000 Leuven, Belgium and Department of Oncology, MRC-CR-UK Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford OX1 2JD (United Kingdom)

    2014-06-15

    Purpose: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy have become standard treatments but are more sensitive to anatomical variations than 3D conformal techniques. To correct for inter- and intrafraction anatomical variations, fast and easy to implement methods are needed. Here, the authors propose a full dosimetric IMRT correction that finds a compromise in-between basic repositioning (the current clinical practice) and full replanning. It simplifies replanning by avoiding a recontouring step and a full dose calculation. It surpasses repositioning by updating the preoptimized fluence and monitor units (MU) using a limited number of fiducial points and a pretreatment (CB)CT. To adapt the fluence the fiducial points were projected in the beam's eye view (BEV). To adapt the MUs, point dose calculation towards the same fiducial points were performed. The proposed method is intrinsically fast and robust, and simple to understand for operators, because of the use of only four fiducial points and the beam data based point dose calculations. Methods: To perform our dosimetric adaptation, two fluence corrections in the BEV are combined with two MU correction steps along the beam's path. (1) A transformation of the fluence map such that it is realigned with the current target geometry. (2) A correction for an unintended scaling of the penumbra margin when the treatment beams scale to the current target size. (3) A correction for the target depth relative to the body contour and (4) a correction for the target distance to the source. The impact of the correction strategy and its individual components was evaluated by simulations on a virtual prostate phantom. This heterogeneous reference phantom was systematically subjected to population based prostate transformations to simulate interfraction variations. Additionally, a patient example illustrated the clinical practice. The correction strategy was evaluated using both dosimetric

  15. A Monte Carlo dosimetric quality assurance system for dynamic intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Takegawa, Hideki; Yamamoto, Tokihiro; Miyabe, Yuki; Teshima, Teruki; Kunugi, Tomoaki; Yano, Shinsuke; Mizowaki, Takashi; Nagata, Yasushi; Hiraoka, Masahiro

    2005-01-01

    We are developing a Monte Carlo (MC) dose calculation system, which can resolve dosimetric issues derived from multileaf collimator (MLC) design for routine dosimetric quality assurance (QA) of intensity-modulated radiotherapy (IMRT). The treatment head of the medical linear accelerator equipped with MLC was modeled using the EGS4 MC code. A graphical user interface (GUI) application was developed to implement MC dose computation in the CT-based patient model and compare the MC calculated results with those of a commercial radiotherapy treatment planning (RTP) system, Varian Eclipse. To reduce computation time, the EGS4 MC code has been parallelized on massive parallel processing (MPP) system using the message passing interface (MPI). The MC treatment head model and MLC model were validated by the measurement data sets of percentage depth dose (PDD) and off-center ratio (OCR) in the water phantom and the film measurements for the static and dynamic test patterns, respectively. In the treatment head model, the MC calculated results agreed with those of measurements for both of PDD and OCR. The MC could reproduce all of the MLC dosimetric effects. A quantitative comparison between the results of MC and Eclipse was successfully performed with the GUI application. Parallel speed-up became almost linear. An MC dosimetric QA system for dynamic IMRT has been developed, however there were large dose discrepancies between the MC and the measurement in the MLC model simulation, which are now being investigated. (author)

  16. A Dosimetric Comparison of Dose Escalation with Simultaneous Integrated Boost for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Wenjuan Yang

    2017-01-01

    Full Text Available Background. Many studies have demonstrated that a higher radiotherapy dose is associated with improved outcomes in non-small-cell lung cancer (NSCLC. We performed a dosimetric planning study to assess the dosimetric feasibility of intensity-modulated radiation therapy (IMRT with a simultaneous integrated boost (SIB in locally advanced NSCLC. Methods. We enrolled twenty patients. Five different dose plans were generated for each patient. All plans were prescribed a dose of 60 Gy to the planning tumor volume (PTV. In the three SIB groups, the prescribed dose was 69 Gy, 75 Gy, and 81 Gy in 30 fractions to the internal gross tumor volume (iGTV. Results. The SIB-IMRT plans were associated with a significant increase in the iGTV dose (P < 0.05, without increased normal tissue exposure or prolonged overall treatment time. Significant differences were not observed in the dose to the normal lung in terms of the V5 and V20 among the four IMRT plans. The maximum dose (Dmax in the esophagus moderately increased along with the prescribed dose (P < 0.05. Conclusions. Our results indicated that escalating the dose by SIB-IMRT is dosimetrically feasible; however, systematic evaluations via clinical trials are still warranted. We have designed a further clinical study (which is registered with ClinicalTrials.gov, number NCT02841228.

  17. Dosimetric response of united, commercially available CTA foils for 60Co gamma rays

    International Nuclear Information System (INIS)

    Peimel-Stuglik, Z.

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for 60 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for 60 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. (author)

  18. Active pixel as dosimetric device for interventional radiology

    International Nuclear Information System (INIS)

    Servoli, L.; Baldaccini, F.; Biasini, M.; Checcucci, B.; Chiocchini, S.; Cicioni, R.; Conti, E.; Di Lorenzo, R.; Dipilato, A.C.; Esposito, A.; Fanó, L.; Paolucci, M.; Passeri, D.; Pentiricci, A.

    2013-01-01

    Interventional Radiology (IR) is a subspecialty of radiology comprehensive of all minimally invasive diagnostic and therapeutic procedures performed using radiological devices to obtain image guidance. The interventional procedures are potentially harmful for interventional radiologists and medical staff due to the X-ray diffusion by the patient's body. The characteristic energy range of the diffused photons spans few tens of keV. In this work we will present a proposal for a new X-ray sensing element in the energy range of interest for IR procedures. The sensing element will then be assembled in a dosimeter prototype, capable of real-time measurement, packaged in a small form-factor, with wireless communication and no external power supply to be used for individual operators dosimetry for IR procedures. For the sensor, which is the heart of the system, we considered three different Active Pixel Sensors (APS). They have shown a good capability as single X-ray photon detectors, up to several tens keV photon energy. Two dosimetric quantities have been considered, the number of detected photons and the measured energy deposition. Both observables have a linear dependence with the dose, as measured by commercial dosimeters. The uncertainties in the measurement are dominated by statistic and can be pushed at ∼5% for all the sensors under test

  19. Effect of stereotactic dosimetric end points on overall survival for Stage I non–small cell lung cancer: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Mulryan, Kathryn; Leech, Michelle; Forde, Elizabeth, E-mail: eforde@tcd.ie

    2015-01-01

    Stereotactic body radiation therapy (SBRT) delivers a high biologically effective dose while minimizing toxicities to surrounding tissues. Within the scope of clinical trials and local practice, there are inconsistencies in dosimetrics used to evaluate plan quality. The purpose of this critical review was to determine if dosimetric parameters used in SBRT plans have an effect on local control (LC), overall survival (OS), and toxicities. A database of relevant trials investigating SBRT for patients with early-stage non–small cell lung cancer was compiled, and a table of dosimetric variables used was created. These parameters were compared and contrasted for LC, OS, and toxicities. Dosimetric end points appear to have no effect on OS or LC. Incidences of rib fractures correlate with a lack of dose-volume constraints (DVCs) reported. This review highlights the great disparity present in clinical trials reporting dosimetrics, DVCs, and toxicities for lung SBRT. Further evidence is required before standard DVCs guidelines can be introduced. Dosimetric end points specific to stereotactic treatment planning have been proposed but require further investigation before clinical implementation.

  20. TU-CD-304-03: Dosimetric Verification and Preliminary Comparison of Dynamic Wave Arc for SBRT Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Burghelea, M [UZ BRUSSEL, Brussels (Belgium); BRAINLAB AG, Munich (Germany); Babes Bolyai University, Cluj-Napoca (Romania); Poels, K; Gevaert, T; Tournel, K; Dhont, J; De Ridder, M; Verellen, D [UZ BRUSSEL, Brussels (Belgium); Hung, C [BRAINLAB AG, Munich (Germany); Eriksson, K [RAYSEARCH LABORATORIES AB, Stockholm (Sweden); Simon, V [Babes Bolyai University, Cluj-Napoca (Romania)

    2015-06-15

    Purpose: To evaluate the potential dosimetric benefits and verify the delivery accuracy of Dynamic Wave Arc, a novel treatment delivery approach for the Vero SBRT system. Methods: Dynamic Wave Arc (DWA) combines simultaneous movement of gantry/ring with inverse planning optimization, resulting in an uninterrupted non-coplanar arc delivery technique. Thirteen SBRT complex cases previously treated with 8–10 conformal static beams (CRT) were evaluated in this study. Eight primary centrally-located NSCLC (prescription dose 4×12Gy or 8×7.5Gy) and five oligometastatic cases (2×2 lesions, 10×5Gy) were selected. DWA and coplanar VMAT plans, partially with dual arcs, were generated for each patient using identical objective functions for target volumes and OARs on the same TPS (RayStation, RaySearch Laboratories). Dosimetric differences and delivery time among these three planning schemes were evaluated. The DWA delivery accuracy was assessed using the Delta4 diode array phantom (ScandiDos AB). The gamma analysis was performed with the 3%/3mm dose and distance-to-agreement criteria. Results: The target conformity for CRT, VMAT and DWA were 0.95±0.07, 0.96±0.04 and 0.97±0.04, while the low dose spillage gradient were 5.52±1.36, 5.44±1.11, and 5.09±0.98 respectively. Overall, the bronchus, esophagus and spinal cord maximum doses were similar between VMAT and DWA, but highly reduced compared with CRT. For the lung cases, the mean dose and V20Gy were lower for the arc techniques compares with CRT, while for the liver cases, the mean dose and the V30Gy presented slightly higher values. The average delivery time of VMAT and DWA were 2.46±1.10 min and 4.25±1.67 min, VMAT presenting shorter treatment time in all cases. The DWA dosimetric verification presented an average gamma index passing rate of 95.73±1.54% (range 94.2%–99.8%). Conclusion: Our preliminary data indicated that the DWA is deliverable with clinically acceptable accuracy and has the potential to

  1. TU-CD-304-03: Dosimetric Verification and Preliminary Comparison of Dynamic Wave Arc for SBRT Treatments

    International Nuclear Information System (INIS)

    Burghelea, M; Poels, K; Gevaert, T; Tournel, K; Dhont, J; De Ridder, M; Verellen, D; Hung, C; Eriksson, K; Simon, V

    2015-01-01

    Purpose: To evaluate the potential dosimetric benefits and verify the delivery accuracy of Dynamic Wave Arc, a novel treatment delivery approach for the Vero SBRT system. Methods: Dynamic Wave Arc (DWA) combines simultaneous movement of gantry/ring with inverse planning optimization, resulting in an uninterrupted non-coplanar arc delivery technique. Thirteen SBRT complex cases previously treated with 8–10 conformal static beams (CRT) were evaluated in this study. Eight primary centrally-located NSCLC (prescription dose 4×12Gy or 8×7.5Gy) and five oligometastatic cases (2×2 lesions, 10×5Gy) were selected. DWA and coplanar VMAT plans, partially with dual arcs, were generated for each patient using identical objective functions for target volumes and OARs on the same TPS (RayStation, RaySearch Laboratories). Dosimetric differences and delivery time among these three planning schemes were evaluated. The DWA delivery accuracy was assessed using the Delta4 diode array phantom (ScandiDos AB). The gamma analysis was performed with the 3%/3mm dose and distance-to-agreement criteria. Results: The target conformity for CRT, VMAT and DWA were 0.95±0.07, 0.96±0.04 and 0.97±0.04, while the low dose spillage gradient were 5.52±1.36, 5.44±1.11, and 5.09±0.98 respectively. Overall, the bronchus, esophagus and spinal cord maximum doses were similar between VMAT and DWA, but highly reduced compared with CRT. For the lung cases, the mean dose and V20Gy were lower for the arc techniques compares with CRT, while for the liver cases, the mean dose and the V30Gy presented slightly higher values. The average delivery time of VMAT and DWA were 2.46±1.10 min and 4.25±1.67 min, VMAT presenting shorter treatment time in all cases. The DWA dosimetric verification presented an average gamma index passing rate of 95.73±1.54% (range 94.2%–99.8%). Conclusion: Our preliminary data indicated that the DWA is deliverable with clinically acceptable accuracy and has the potential to

  2. Dosimetric properties of a Solid Water High Equivalency (SW557) phantom for megavoltage photon beams.

    Science.gov (United States)

    Araki, Fujio

    2017-07-01

    The dosimetric properties of the recently developed SW557 phantom have been investigated by comparison with those of the existing SW457 phantom in megavoltage photon beams. The electron fluence ratio φ pl w , and chamber ionization ratio k pl , of water to SW457 and water to SW557 for 4-15MV photons were calculated as a function of depth using Monte Carlo simulations, and compared with measured values. Values of φ pl w for SW457 were in the range of 1.004-1.014 for 4MV, and 1.014-1.018 for 15MV photons. The φ pl w for SW557 ranged from 1.005 to 1.008 for 4MV and from 1.010 to 1.015 for 15MV photons and the variation of φ pl w with depth for each beam energy was within ±0.5%. Values of k pl were obtained with a PTW 30013 Farmer-type ionization chamber. The k pl for SW457 ranged from 0.997 to 1.011 for 4-15MV photons. Values of k pl for SW557 were almost unity for 4 and 6MV photons, while in the case of 10 and 15MV photons they were less than 1.006, excepting the build-up region. The measured and calculated k pl values of water to SW557 were in the range of 0.997-1.002 and 1.000-1.006, respectively, for 4-15MV photons, at a depth of 10cm with a source-to-axis distance of 100cm. The measured and calculated k pl values were in agreement within their uncertainty ranges. As a water-equivalent phantom, SW557 can be used with a dosimetric difference within±0.6%, for 4-15MV photons, and is more water-equivalent than SW457 in megavoltage photon beams. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. The effect of interobserver differences in post-implant prostate CT image interpretation on dosimetric parameters

    International Nuclear Information System (INIS)

    Han, Ben H.; Wallner, Kent; Merrick, Gregory; Badiozamani, Kas; Butler, Wayne

    2003-01-01

    The purpose of this study was to clarify where observers differ in their interpretation of CT scans, and to relate those differences to clinically relevant dosimetric parameters. Twenty unselected patients treated with I-125 or Pd-103 brachytherapy at the Veterans Affairs Puget Sound Health Care System (VAPSHCS) in 2001 were studied. Patients were implanted with I-125 (7 patients, 0.87 mCi/source) or Pd-103 (13 patients, 2.54 U/source). The number of I-125 sources implanted ranged from 52 to 78. The number of Pd-103 sources implanted ranged from 58-144. Post-implant 3 mm CT images were imported into a laptop running Varian Variseed trade mark sign and sent to the four physician investigators, who outlined the prostate independently. Investigators were not coached specifically for this study, beyond their having read prior reports regarding prostate volume determinations. There was moderate interobserver variability in CT volume determination, with the standard deviations as a percent of the mean ranging from 9% to 29% (median: 17%). An average of 14% of implants (range: 5%-20%) would have been judged inadequate based on a minimum V100 of 80%, versus 24% of implants (range: 5%-45%) being judged inadequate based on a minimum D90 of 90% of prescription dose. The greatest variability was seen in prostate length (median standard deviation: 0.57 cm), due to vagaries in base and apical localization. However, the prostatic width and thickness also varied substantially between observers, with median standard deviations of 0.24 and 0.32 cm, respectively. Treatment margin variability was greatest at the anterior border, with a median standard deviation of 0.21 cm±0.10. We believe that CT-based dosimetry, while influenced by CT interpretation, still provides useful general dosimetric calculations, that are likely to be reproducible enough to provide clinically useful information between institutions. The V100 and TMs are less influenced by interobserver CT interpretation

  4. Simulation of The ICRP-30 Dosimetric Model for the Respiratory Tract

    International Nuclear Information System (INIS)

    Giaddui, T.; Atia, M. A.

    2004-01-01

    Matlab was used to write a simulation program (ACID1) to simulate the ICRP-30 dosimetric model for the respiratory tract. The program (a new version of the one presented at the sixth Arab conference held in Cairo 2002) calculates a series of dosimetric quantities for the reference man as a result of the inhalation of any radionuclide. The program also plots the variation of activity with time for all organs and provided with a graphical user interface to make it friendly user. The results obtained by this program was compared with similar results obtained by other source and found to be very close. (Authors)

  5. Portal imaging practice patterns of children's oncology group institutions: Dosimetric assessment and recommendations for minimizing unnecessary exposure

    International Nuclear Information System (INIS)

    Olch, Arthur J.; Geurts, Mark; Thomadsen, Bruce; Famiglietti, Robin; Chang, Eric L.

    2007-01-01

    Purpose: To determine and analyze the dosimetric consequences of current portal imaging practices for pediatric patients, and make specific recommendations for reducing exposure from portal imaging procedures. Methods and Materials: A survey was sent to approximately 250 Children's Oncology Group (COG) member institutions asking a series of questions about their portal imaging practices. Three case studies are presented with dosimetric analysis to illustrate the magnitude of unintended dose received by nontarget tissues using the most common techniques from the survey. Results: The vast majority of centers use double-exposure portal image techniques with a variety of open field margins. Only 17% of portal images were obtained during treatment, and for other imaging methods, few centers subtract monitor units from the treatment delivery. The number of monitor units used was nearly the same regardless of imager type, including electronic portal imaging devices. Eighty-six percent imaged all fields the first week and 17% imaged all fields every week. An additional 1,112 cm 3 of nontarget tissue received 1 Gy in one of the example cases. Eight new recommendations are made, which will lower nontarget radiation doses with minimal impact on treatment verification accuracy. Conclusion: Based on the survey, changes can be made in portal imaging practices that will lower nontarget doses. It is anticipated that treatment verification accuracy will be minimally affected. Specific recommendations made to decrease the imaging dose and help lower the rate of radiation-induced secondary cancers in children are proposed for inclusion in future COG protocols using radiation therapy

  6. Dosimetric characterization of chemical-vapor-deposited diamond film irradiated with UV and beta radiation

    Science.gov (United States)

    Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M.

    2003-03-01

    Diamond is an excellent prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality polycrystalline has renewed the interest in using diamond films as detectors and dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by using chemical vapor deposition. The thermoluminescence (TL) of UV and beta exposed samples shows a glow curve composed of at least four peaks; one located around 587 K presents excellent TL properties suitable for dosimetric applications with ionizing and non ionizing radiation. The TL excitation spectrum exhibits maximum TL efficiency at 220 nm. The samples show regions of linear as well as supralinear behavior as a function or irradiation dose. The linear dose dependence was found for up to sixteen minutes of UV irradiation and 300 Gy for beta irradiated samples. The activation energy and the frequency factor were determined and found in the range of 0.32 - 0.89 eV and 1.1x10^2 - 2x10^8s_-1, respectively. The observed TL performance is reasonable appropriate to justify further investigation of diamond films as radiation dosimeters.

  7. Dosimetric characterization of a commercial two-dimensional array detector; Caracterizacao dosimetrica de um detector matricial bidimensional comercial

    Energy Technology Data Exchange (ETDEWEB)

    Gialluisi, Bruno L.; Santos, Gabriela R. dos; Sales, Camila P. de; Resende, Guilherme R.A.; Habitzreuter, Angela B.; Rodrigues, Laura N., E-mail: brunogialluisi@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2013-04-15

    This paper investigates the dosimetric characteristics and performance of an array detector commercially available. The device is the I'mRT MatriXX® which is a two-dimensional detector array used in the verification of complex radiotherapy plans. It consists of 1,020 parallel plate ion chamber arranged in a 32x32 grid. Dose linearity was studied and its response was linear within the range of 5 to 1000 MU (R{sup 2} = 1). Dose rate dependence showed a maximum deviation of 0,62% comparatively with readings to 320 cGy/min. The detector stability was verified through repeated irradiations. Output factors matched well with measurements made with a Farmer chamber with an average deviation of 1,54%. The detector's effective point of measurement was determined and the inverse square law was also verified with a percentage deviation smaller than 3%. The results show that this detector can be used for quality control in IMRT thus reducing the time spent in the dosimetric verification of radiation fields. (author)

  8. Dosimetric characterization of a commercial two-dimensional array detector; Caracterizacao dosimetrica de um detector matricial bidimensional comercial

    Energy Technology Data Exchange (ETDEWEB)

    Gialluisi, Bruno L.; Santos, Gabriela R. dos; Sales, Camila P. de; Resende, Guilherme R.A.; Habitzreuter, Angela B.; Rodrigues, Laura N., E-mail: brunogialluisi@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2013-04-15

    This paper investigates the dosimetric characteristics and performance of an array detector commercially available. The device is the I'mRT MatriXX® which is a two-dimensional detector array used in the verification of complex radiotherapy plans. It consists of 1,020 parallel plate ion chamber arranged in a 32x32 grid. Dose linearity was studied and its response was linear within the range of 5 to 1000 MU (R{sup 2} = 1). Dose rate dependence showed a maximum deviation of 0,62% comparatively with readings to 320 cGy/min. The detector stability was verified through repeated irradiations. Output factors matched well with measurements made with a Farmer chamber with an average deviation of 1,54%. The detector's effective point of measurement was determined and the inverse square law was also verified with a percentage deviation smaller than 3%. The results show that this detector can be used for quality control in IMRT thus reducing the time spent in the dosimetric verification of radiation fields. (author)

  9. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE

    International Nuclear Information System (INIS)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L.

    2001-01-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10 5 Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  10. An evaluation of the dosimetric performance characteristics of N-vinylpyrrolidone-based polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, A E [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Maris, T G [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Zacharopoulou, F [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Pappas, E [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Zacharakis, G [Institute of Electronic Structure and Laser (IESL), Foundation for Research and Technology-Hellas (FORTH), PO Box 1527, Iraklion, Crete (Greece); Damilakis, J [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece)

    2007-08-21

    The aim of this work was to investigate the dosimetric performance properties of the N-vinylpyrrolidone argon (VIPAR) based polymer gel as a dosimetric tool in clinical radiotherapy. VIPAR gels with a larger concentration of gelatin than the standard recipe were manufactured and irradiated up to 68 Gy using a 6 and 18 MV linear accelerator. Using MRI, the R2-dose response was recorded at different imaging sessions within a 34 day time period post-irradiation. The R2-dose response was found to be linear between 5 and 68 Gy. Although dose sensitivity did not show significant variation with time, the measured R2-dose values showed an increasing trend, which was less evident beyond 17 days. At one day post-irradiation, calculated dose standard uncertainties at 20 Gy and 56 Gy were 2.2% and 1.7%, providing a dose resolution of 0.45 Gy and 0.97 Gy, respectively. Although these values fulfilled the 2% limit of ICRU, when gels were imaged at one day post-irradiation, it was shown that the temporal evolution of the R2 values deteriorated the per cent standard uncertainty and the dose resolution by {approx}57%, when imaged 17 days post-irradiation. Variation in the coagulation temperature of the gels did not impact the R2-dose sensitivity. This study has shown that the VIPAR gel has the properties of a dosimetric tool required in clinical radiotherapy, especially in applications where a wide dose dynamic range is employed. For results with the lowest per cent uncertainty and the optimum dose resolution, the dosimetry gels used in this work should be MR scanned at one day post-irradiation. Furthermore, a preliminary study on the R2-dose response of a new normoxic N-vinylpyrrolidone-based polymer gel showed that it could potentially replace the traditional VIPAR gel formulation, while preserving the wide dynamic dose response inherent to that monomer.

  11. Medical Dosimetric Registry of Russian Atomic Industry Employees: Current Status and Perspectives

    International Nuclear Information System (INIS)

    Ilyin, L. A.; Kiselev, M. F.; Panfilov, A. P.; Kochetkov, O. A.; Ivanov, A. A.; Grinev, M. P.; Soloviev, V. Y.; Semenov, V. G.; Tukov, A. R.; Koshuurnikova, N. A.; Takhauov, R. M.; Melnikov, G. Y.

    2004-01-01

    Epidemiological studies of nuclear industry personnel contain the significant abilities to assess the prolonged radiation exposure effects in the human health. The clarification of these assessments and following improvements of the scientific justification of radiation regulation require the expansion of factual basis of the research currently, Branch Medical Dosimetric Registry (BMDR) of atomic industry and nuclear power employees is under the development in Russian to compose a number of regional registries. This work is coordinated by the State Research Center- Institute of Biophysics (Moscow). The first phase of this project was devoted to the forming of the regional registry of Mayak PA employees (Ozersk, South Uranl region). the employee registries of Siberian Chemical Plant (SCP, Seversk, Tomsk region) and Mountain Chemical Plant (MCP, Zheleznogorsk, Krasnoyarsk region) are at the finalization. At later phases, BMDR will be added by the information on other enterprises and on operating NPP too. The paper describes the structure, general issues of the forming and current status of BMDR. The comparison of major BMDR features versus LSS registry (which is the one of basic components for international radiation protection recommendations and current radiation protection standards) demonstrates that BMDR information can be more preferable to assess the significance of the man made radiation at high and intermediate dose ranges. Particularly, the number of employees (20-40 year age range) exposed to doses specific to detectable radiation health effects (above 2000 mSv) is almost ten times more than that for LSS cohort. Besides, the health monitoring was elaborated since the employment start point (Whereas, since year 5 for LSS cohort). BMDR dose records were measured (against LSS reconstructed doses) and the employee exposure duration was equal to years and decade (alternatively to momentary exposure recorded in LSS). BMDR data quantity and quality correspond to

  12. The revised International Commission on Radiological Protection (ICRP) dosimetric model for the human respiratory tract

    International Nuclear Information System (INIS)

    Bair, W.J.

    1992-05-01

    A task group has revised the dosimetric model of the respiratory tract used to calculate annual limits on intake of radionuclides. The revised model can be used to project respiratory tract doses for workers and members of the public from airborne radionuclides and to assess past exposures. Doses calculated for specific extrathoracic and thoracic tissues can be adjusted to account for differences in radiosensitivity and summed to yield two values of dose for the respiratory tract that are applicable to the ICRP tissue weighted dosimetry system

  13. Dosimetric characteristics of Thermo-Shield material for orthovoltage photon beams

    International Nuclear Information System (INIS)

    Bahmaid, Mohammad; Kim, Siyong; Liu, Chihray R.; Palta, Jatinder R.

    2003-01-01

    Conventionally, lead has been used for field shaping in orthovoltage radiation therapy. Recently, a compensator material named Thermo-Shield was presented for field shaping in electron beams. Thermo-Shield is composed of nontoxic, high atomic weight metal particles dispersed in a thermoplastic matrix. It is manually moldable and conforms to human anatomy or any shape at temperatures of 108-132 degree sign F. It is reusable and can be continuously reshaped to better fit the treatment field. Dosimetric characteristics of thermoplastic material were studied for Philips RT250 orthovoltage photon beams ranging from 75 to 250 kVp. It was found that Thermo-Shield should be four to five times thicker than lead to achieve the same transmission (less than 5%). However, it did not cause significant degradation in penumbra. Clinical procedures for use are discussed

  14. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    International Nuclear Information System (INIS)

    Cunha, Elisete L.; Schimitberger, Thiago

    2017-01-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm -1 and 3271 cm -1 , with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  15. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Elisete L.; Schimitberger, Thiago, E-mail: elisete.cunha@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Oliveira, Cristiana M.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm{sup -1} and 3271 cm{sup -1}, with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  16. The dilemma of parotid gland and pharyngeal constrictor muscles preservation—Is daily online image guidance required? A dosimetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Duffy, Olivia; Forde, Elizabeth; Leech, Michelle, E-mail: leechm@tcd.ie

    2017-04-01

    With margin reduction common in head and neck radiotherapy, it is critical that the dosimetric effects of setup deviations are quantified. With past studies focusing on the quantification of positional and volumetric changes of organs at risk (OARs), this study aimed to measure the dose delivered to these the parotid gland (PG) and pharyngeal constrictor muscles (PCMs) using cone beam computed tomography (CBCT). Furthermore, this investigation sought to establish a potential time trend of change in dose delivered to target volumes secondary to ascertaining the need for daily image guidance (IG) to reduce the dose burden to these important OARs. Intensity modulated radiotherapy (IMRT) plans for 5 locally advanced head and neck patients' plans were created and mapped to weekly CBCTs. Each plan was recalculated without heterogeneity correction allowing for dosimetric comparison. Dosimetric endpoints recorded to assess the effect of positional variation were as per ICRU 83 and included D{sub 95} and D{sub 98} for the target volumes, mean dose (MD) and V{sub 30} {sub Gy} for the PGs, and V{sub 50} {sub Gy} and MD for the PCMs. Results were deemed statistically significant if p < 0.05. No significant time trends were established for these OARs. A significant decrease in V{sub 50} {sub Gy} was observed for all PCMs (p < 0.001) on all CBCTs relative to the original plan. Regarding target volumes, a highly significant decrease in MD (MD = 20 Gy, CI: −20.310 to −19.820) in D{sub 98} of the high-dose planning target volume (PTV [70 Gy]; PTVD{sub 98%} = 70 Gy) for case 3 was found (p ≤ 0.001). A nonpredictable, yet significant dosimetric effect was found. A clinically acceptable balance must be achieved between OAR dosimetry and target coverage as can be achieved by frequent IG.

  17. Model dosimetric for Radon and Daughters

    International Nuclear Information System (INIS)

    Puerta, J.A.; Cardenas, H.F.

    1998-01-01

    You elaborates a model dosimetric for radon and their products of decline of short half life starting from the new model of the breathing tract of the publication 66 of the ICRP and the use of the systemic models proposed in the publication 67, 68 and 69 of the same commission. The correlated used methodology the incorporation of these radionuclides with the activity in organs and you excrete, considering the difference of metabolic behavior of the products of decline and of their predecessor

  18. The effects of pre-dose and annealing temperature on some dosimetric properties of thermoluminescence of quartz

    International Nuclear Information System (INIS)

    Lin Zhikai

    1996-02-01

    The following aspects of dosimetric properties of quartz sample were studied. (1) The changes in dosimetric sensitivity of quartz with different pre-doses under different annealing temperature; (2) the option of optimal annealing temperature which can make the dosimetric sensitivity of quartz to restore its original level; (3) The changes in dosimetric sensitivity of quartz with different annealing time at 500 degree C for 8 h; (4) Repeated experiments were carried out in order to prove whether the sensitivity of quartz can restore its original level at annealing temperature 700 degree C for 3 h. It has been found that at 700 degree C for 3 h gave the least sensitivity change and the sensitivity of quartz almost restored its original level. Repeated experiments with four kinds of quartz sample confirmed this conclusion. The dramatic change of TL glow curve occurred only at the condition of annealing temperature 900 degree C for 1 h. This result was different from that obtained by D. J. Huntley et al. (1988). (3 refs., 4 figs., 1 tab.)

  19. SU-G-TeP3-11: Radiobiological-Cum-Dosimetric Quality Assurance of Complex Radiotherapy Plans

    Energy Technology Data Exchange (ETDEWEB)

    Paudel, N; Narayanasamy, G; Zhang, X; Penagaricano, J; Morrill, S [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Mavroidis, P [University North Carolina, Chapel Hill, NC (United States); Pyakuryal, A [National Cancer Institute, Rockville, MD (United States); Han, E [UT MD Anderson Cancer Center, Houston, TX (United States); Liang, X [University of Florida Health Proton Therapy Institute, Jacksonville, FL (United States); Kim, D [Kyung Hee University Hospital, Seol (Korea, Republic of)

    2016-06-15

    Purpose: Dosimetric gamma-analysis used for QA of complex radiotherapy plans tests the dosimetric equivalence of a delivered plan with the treatment planning system (TPS) optimized plan. It does not examine whether a dosimetric difference results in any radiobiological difference. This study introduces a method to test the radiobiological and dosimetric equivalence between a delivered and the TPS optimized plan. Methods: Six head and neck and seven lung cancer VMAT or IMRT plans optimized for patient treatment were calculated and delivered to an ArcCheck phantom. ArcCheck measured dose distributions were compared with the TPS calculated dose distributions using a 2-D gamma-analysis. Dose volume histograms (DVHs) for various patient structures were obtained by using measured data in 3DVH software and compared against the TPS calculated DVHs using 3-D gamma analysis. DVH data were used in the Poisson model to calculate tumor control probability (TCP) for the treatment targets and in the sigmoid dose response model to calculate normal tissue complication probability (NTCP) for the normal structures. Results: Two-D and three-D gamma passing rates among six H&N patient plans differed by 0 to 2.7% and among seven lung plans by 0.1 to 4.5%. Average ± SD TCPs based on measurement and TPS were 0.665±0.018 and 0.674±0.044 for H&N, and 0.791±0.027 and 0.733±0.031 for lung plans, respectively. Differences in NTCPs were usually negligible. The differences in dosimetric results, TCPs and NTCPs were insignificant. Conclusion: The 2-D and 3-D gamma-analysis based agreement between measured and planned dose distributions may indicate their dosimetric equivalence. Small and insignificant differences in TCPs and NTCPs based on measured and planned dose distributions indicate the radiobiological equivalence between the measured and optimized plans. However, patient plans showing larger differences between 2-D and 3-D gamma-analysis can help us make a more definite conclusion

  20. Thermoluminescence dosimetric characteristics of thulium doped ZnB{sub 2}O{sub 4} phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Madhusoodanan, U. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Subramanian, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai (India); Venkatraman, B. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai (India)

    2014-02-15

    Polycrystalline powder samples of rare earth doped Zinc borates were synthesized by high temperature solid state diffusion technique. Dosimetric characteristics of the phosphor like thermoluminescence glow curve, TL emission spectra, dose–response, fading studies, reproducibility and reusability studies were carried out on the synthesized phosphors. Among the different rare earth doped phosphors, thulium doped zinc borate was found to have a higher sensitivity. Hence detailed dosimetric characteristics of this phosphor were carried out. It is observed that the dose–response is linear from 10 mGy to 10{sup 3} Gy in this phosphor. EPR measurements were carried out on unirradiated, gamma irradiated and annealed phosphors to identify the defect centers responsible for thermoluminescence. A TL model is proposed based on the EPR studies in these materials. Kinetic parameters were evaluated for the dosimetric peaks using various methods. The experimental results show that this phosphor can have potential applications in radiation dosimetry applications. -- Highlights: • Polycrystalline powder samples of rare earth doped zinc borates were synthesized. • Thulium was observed to be the most efficient dopant in ZnB{sub 2}O{sub 4} lattice. • TL intensity of the dosimetric peak is around 20 times that of TLD-100. • Based on EPR studies a TL mechanism is proposed in zinc borate. • Deconvolution of the glow curve carried out.

  1. Dosimetric improvements following 3D planning of tangential breast irradiation

    International Nuclear Information System (INIS)

    Aref, Amr; Thornton, Dale; Youssef, Emad; He, Tony; Tekyi-Mensah, Samuel; Denton, Lori; Ezzell, Gary

    2000-01-01

    Purpose: To evaluate the dosimetric difference between a simple radiation therapy plan utilizing a single contour and a more complex three-dimensional (3D) plan utilizing multiple contours, lung inhomogeneity correction, and dose-based compensators. Methods and Materials: This is a study of the radiation therapy (RT) plans of 85 patients with early breast cancer. All patients were considered for breast-conserving management and treated by conventional tangential fields technique. Two plans were generated for each patient. The first RT plan was based on a single contour taken at the central axis and utilized two wedges. The second RT plan was generated by using the 3D planning system to design dose-based compensators after lung inhomogeneity correction had been made. The endpoints of the study were the comparison between the volumes receiving greater than 105% and greater than 110% of the reference dose, as well as the magnitude of the treated volume maximum dose. Dosimetric improvement was defined to be of significant value if the volume receiving > 105% of one plan was reduced by at least 50% with the absolute difference between the volumes being 5% or greater. The dosimetric improvements in 49 3D plans (58%) were considered of significant value. Patients' field separation and breast size did not predict the magnitude of improvement in dosimetry. Conclusion: Dose-based compensator plans significantly reduced the volumes receiving > 105%, >110%, and volume maximum dose.

  2. SU-E-J-170: Dosimetric Consequences of Uncorrected Rotational Setup Errors During Stereotactic Body Radiation Therapy (SBRT) Treatment of Pancreatic Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Di Maso, L [Chicago, IL (United States); Forbang, R Teboh; Zhang, Y; Herman, J; Lee, J [John Hopkins University, Baltimore, MD (United States)

    2015-06-15

    Purpose: To explore the dosimetric consequences of uncorrected rotational setup errors during SBRT for pancreatic cancer patients. Methods: This was a retrospective study utilizing data from ten (n=10) previously treated SBRT pancreas patients. For each original planning CT, we applied rotational transformations to derive additional CT images representative of possible rotational setup errors. This resulted in 6 different sets of rotational combinations, creating a total of 60 CT planning images. The patients’ clinical dosimetric plans were then applied to their corresponding rotated CT images. The 6 rotation sets encompassed a 3, 2 and 1-degree rotation in each rotational direction and a 3-degree in just the pitch, a 3-degree in just the yaw and a 3-degree in just the roll. After the dosimetric plan was applied to the rotated CT images, the resulting plan was then evaluated and compared with the clinical plan for tumor coverage and normal tissue sparing. Results: PTV coverage, defined here by V33 throughout all of the patients’ clinical plans, ranged from 92–98%. After an n degree rotation in each rotational direction that range decreased to 68–87%, 85–92%, and 88– 94% for n=3, 2 and 1 respectively. Normal tissue sparing defined here by the proximal stomach V15 throughout all of the patients’ clinical plans ranged from 0–8.9 cc. After an n degree rotation in each rotational direction that range increased to 0–17 cc, 0–12 cc, and 0–10 cc for n=3, 2, and 1 respectively. Conclusion: For pancreatic SBRT, small rotational setup errors in the pitch, yaw and roll direction on average caused under dosage to PTV and over dosage to proximal normal tissue. The 1-degree rotation was on average the least detrimental to the normal tissue and the coverage of the PTV. The 3-degree yaw created on average the lowest increase in volume coverage to normal tissue. This research was sponsored by the AAPM Education Council through the AAPM Education and Research

  3. Range and energy functions of interest in neutron dosimetry

    International Nuclear Information System (INIS)

    Bhatia, D.P.; Nagarajan, P.S.

    1978-01-01

    This report documents the energy and range functions generated and used in fast neutron interface dosimetry studies. The basic data of stopping power employed are the most recent. The present report covers a number of media mainly air, oxygen, nitrogen, polythene, graphite, bone and tissue, and a number of charged particles, namely protons, alphas, 9 Be, 11 B, 12 C, 13 C, 14 N and 16 O. These functions would be useful for generation of energy and range values for any of the above particles in any of the above media within +- 1% in any dosimetric calculations. (author)

  4. Dosimetric characteristics of a 6 MV photon beam from a linear accelerator with asymmetric collimator jaws

    International Nuclear Information System (INIS)

    Palta, J.R.; Ayyangar, K.M.; Suntharalingam, N.

    1988-01-01

    Dosimetric measurements have been made of a 6 MV photon beam from a linear accelerator equipped with asymmetric jaws. The field size factors for asymmetrically set fields are compared to those for symmetrically set fields. The change of beam quality has been measured as a function of off-axis position of the asymmetric fields to assess its effect on depth dose. Additional measurements include beam penumbra and shape of isodose curves for open and wedge fields as the field opening is moved asymmetrically from the central ray

  5. Dosimetric study in iodine-125 seeds for brachytherapy application

    International Nuclear Information System (INIS)

    Zeituni, Carlos Alberto

    2008-01-01

    The demand for iodine-125 seeds for use in brachytherapy treatments has experienced an increase along recent years in Brazil and all over the world. All iodine-125 seed must have its operational parameters measured and/or calculated every time changes in the production process are carried out. A complete dosimetric measurement is very expensive, and it is recommended that this procedure must be repeated at least once a year. Thus, this work developed a methodology for the entire dosimetric process. This methodology is based on the scarce information available in the literature, once almost all the methodology used in large industrial laboratories is commercial secret. The proposed methodology was tested using seeds of Amersham-Oncura-Ge Healthcare, which is the largest seed manufactory in the world. In this new methodology, an automatic reader was employed in order to reduce the time required in the selection process of the TLD-100 dosimeters used and a postprocessing of the obtained spectra was carried out. A total of 142 dosimeters were used and only 29 have been selected using the new methodology. Measurements were performed using slabs of Solid Water RW1 to simulate measuring in the 'water', using three different experimental apparatus and each measurement was repeated at least three times. The TLD-100 calibration was performed using a Dermopan II - Siemens. The measured values showed a good agreement with the ones available in the literature. Finally, these measured values were compared with calculated ones obtained by a semiempirical simulation program, showing a good agreement and, therefore, demonstrating the validity of the proposed methodology regarding dosimetric calculations. (author)

  6. Dosimetric investigation depending on tumor location in patient breast in partial breast irradiation

    International Nuclear Information System (INIS)

    Kim, Min Joo; Park, So Hyun; Jung, Joo Young; Woong, Cho; Suh, Tae Suk

    2012-01-01

    The Partial Breast Irradiation (PBI) technique, which involves radiation beam delivery techniques that use a limited range of treatment volumes, has been a challenging approach that is worthy of consideration compared to whole-breast radiation therapy (WBRT). Because of a small target volumes used in the PBI technique, the radiation dose can be safely delivered to the targeted tissue without the unwanted delivery of radiation to normal breast tissues and organ at risk (OAR), such as contralateral breast, lung and heart.Through PBI technique, better cosmetic outcomes and minimizing damages to OARs could be expected and also the daily dose can be increased with smaller number of fractionation in radiation therapy. The purpose of this study was to evaluate the dosimetric effects according to tumor locations in patient's breast for Partial Breast Irradiation (PBI) technique using three Dimensional Conformal Radiation Therapy (3DCRT), Electron Beam Radiation therapy (EBRT) and Helical-tomotherapy (H-TOMO). Dosimetric comparisons of PBI technique for 3DCRT, EBRT, and H-TOMO depending on the classified tumor locations were performed. H-TOMO delivered the low dose to lager volume to surrounding normal tissue, such as the heart and lungs compared to 3DCRT and EBRT although it had the same degree of target coverage as the other methods (3DCRT, EBRT). EBRT had a curative effect for early-stage breast cancers located in the lower and inner sections (LIQ-S, LIQ-D)

  7. Quantitative dosimetric assessment for effect of gold nanoparticles as contrast media on radiotherapy planning

    Science.gov (United States)

    Tu, Shu-Ju; Yang, Pei-Ying; Hong, Ji-Hong; Lo, Ching-Jung

    2013-07-01

    In CT planning for radiation therapy, patients may be asked to have a medical procedure of contrast agent (CA) administration as required by their physicians. CA media improve quality of CT images and assist radiation oncologists in delineation of the target or organs with accuracy. However, dosimetric discrepancy may occur between scenarios in which CA media are present in CT planning and absent in treatment delivery. In recent preclinical experiments of small animals, gold nanoparticles (AuNPs) have been identified as an excellent contrast material of x-ray imaging. In this work, we quantitatively evaluate the effect of AuNPs to be used as a potential material of contrast enhancement in radiotherapy planning with an analytical phantom and clinical case. Conray 60, an iodine-based product for contrast enhancement in clinical uses, is included as a comparison. Other additional variables such as different concentrations of CA media, radiation delivery techniques and dose calculation algorithms are included. We consider 1-field AP, 4-field box, 7-field intensity modulated radiation therapy (IMRT) and a recent technique of volumetric modulated arc therapy (VMAT). CA media of AuNPs (Conray 60) with concentrations of 10%, 20%, 30%, 40% and 50% containing 28.2, 56.4, 84.6, 112.8 and 141.0 mg of gold (iodine) per mL were prepared prior to CT scanning. A virtual phantom with a target where nanoparticle media are loaded and clinical case of gastric lymphoma in which the Conray 60 media were given to the patient prior to the CT planning are included for the study. Compared to Conray 60 media with concentration of 10%/50%, Hounsfield units for AuNP media of 10%/50% are 322/1608 higher due to the fact that atomic number of Au (Z=79) is larger than I (Z=53). In consequence, dosimetric discrepancy of AuNPs is magnified between presence and absence of contrast media. It was found in the phantom study that percent dose differences between presence and absence of CA media may be

  8. Dosimetric properties of Gafchromic (registered) EBT films in medical carbon ion beams

    International Nuclear Information System (INIS)

    MartisIkova, Maria; Jaekel, Oliver

    2010-01-01

    High spatial resolution is desired for dosimetrical verification of patient plans for radiotherapy treatments employing scanned ion beams. This is provided by Gafchromic EBT film, the ancestor of currently available EBT2 films. In this contribution, dosimetric properties of EBT films were investigated. Measurements of depth response were performed for monoenergetic fields (250 MeV/u) for different ion fluences as well as for an energy-modulated spread-out Bragg peak of 5 x 5 x 5 cm 3 in 10 cm depth. The films were positioned perpendicular to the incoming carbon ion beams. The observed quenching of the response relative to the same dose of photons was quantified by the relative efficiency. In monenenergetic beams, a relative efficiency of about 0.73 was found in the plateau, 0.4 in the peak and 0.55 in the tail region. No dependence of the relative efficiency on the ion fluence was observed well beyond the clinically used levels. This gives a constant peak to plateau ratio, which is about 1.8 times lower than that for the delivered dose. In the spread-out Bragg peak, the relative efficiency was found to decrease from 0.64 to 0.54 toward the distal end. Thus when aiming for a prediction of the film response in mixed ion beams, the efficiency of the film has to be parametrized as a function of the ion type and energy over the whole ion spectrum. In addition, the relative water-equivalent range of EBT films was measured here to be 1.291 ± 0.015.

  9. Effect of photon energy spectrum on dosimetric parameters of brachytherapy sources.

    Science.gov (United States)

    Ghorbani, Mahdi; Mehrpouyan, Mohammad; Davenport, David; Ahmadi Moghaddas, Toktam

    2016-06-01

    The aim of this study is to quantify the influence of the photon energy spectrum of brachytherapy sources on task group No. 43 (TG-43) dosimetric parameters. Different photon spectra are used for a specific radionuclide in Monte Carlo simulations of brachytherapy sources. MCNPX code was used to simulate 125I, 103Pd, 169Yb, and 192Ir brachytherapy sources. Air kerma strength per activity, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated and isodose curves were plotted for three different photon energy spectra. The references for photon energy spectra were: published papers, Lawrence Berkeley National Laboratory (LBNL), and National Nuclear Data Center (NNDC). The data calculated by these photon energy spectra were compared. Dose rate constant values showed a maximum difference of 24.07% for 103Pd source with different photon energy spectra. Radial dose function values based on different spectra were relatively the same. 2D anisotropy function values showed minor differences in most of distances and angles. There was not any detectable difference between the isodose contours. Dosimetric parameters obtained with different photon spectra were relatively the same, however it is suggested that more accurate and updated photon energy spectra be used in Monte Carlo simulations. This would allow for calculation of reliable dosimetric data for source modeling and calculation in brachytherapy treatment planning systems.

  10. SU-F-T-221: An Assessment of the Potential for Improved Local Control of Skull- Base Chordomas Via Reduction of the Proton Beam Range Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Muller, L; Soldner, A; Kirk, M; Fager, M; Solberg, T; Robert, L; Dolney, D [University of Pennsylvania, Philadelphia, PA (United States)

    2016-06-15

    Purpose: The beam range uncertainty presents a special challenge for proton therapy. Novel technologies currently under development offer strategies to reduce the range uncertainty [1,2]. This work quantifies the potential advantages that could be realized by such a reduction for dosimetrically challenging chordomas at the base of skull. Therapeutic improvement was assessed by evaluating tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP). Methods: Treatment plans were made for a modulated-scanned proton delivery technique using the Eclipse treatment planning system. The prescription dose was 7920 cGy to the CTV. Three different range uncertainty scenarios were considered: 5 mm (3.5% of the beam range + 1 mm, representing current clinical practice, “Curr”), 2 mm (1.3%), and 1 mm (0.7%). For each of 4 patients, 3 different PTVs were defined via uniform expansion of the CTV by the value of the range uncertainty. Tumor control probability (TCP) and normal tissue complication probabilities (NTCPs) for organs-at-risk (OARs) were calculated using the Lyman-Kutcher-Burman[3] formalism and published model parameters [ref Terahara[4], quantec S10, Burman Red Journal v21 pp 123]. Our plan optimization strategy was to achieve PTV close to prescription while maintaining OAR NTCP values at or better than the Curr plan. Results: The average TCP values for the 5, 2, and 1 mm range uncertainty scenarios are 51%, 55% and 65%. The improvement in TCP for patients was between 4 and 30%, depending primarily on the proximity of the GTV to OAR. The average NTCPs for the brainstem and cord were about 4% and 1%, respectively, for all target margins. Conclusion: For base of skull chordomas, reduced target margins can substantially increase the TCP without increasing the NTCP. This work demonstrates the potential significance of a reduction in the range uncertainty for proton beams.

  11. Safety assessment of outdoor live fire range

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the outdoor live fire range facility (LFR). The purpose of this facility is to supplement the indoor LFR. In particular it provides capacity for exercises that would be inappropriate on the indoor range. This SA examines the risks that are attendant to the training on the outdoor LFR. The outdoor LFR used by EG&G Mound is privately owned. It is identified as the Miami Valley Shooting Grounds. Mondays are leased for the exclusive use of EG&G Mound.

  12. Quality control of dosimetric systems using thermoluminescent crystals

    International Nuclear Information System (INIS)

    Mahecha, L.; Plazas, M. C.; Machado, M.; Perea, M. D.

    2006-01-01

    To achieve an optimal tumoral control to prostate cancer in early and locally advanced stages, it is necessary to increase the dose with a low mobility probability at the vesicle an rectal level. This is achieved through conformal radiotherapy. The Instituto Nacional de Cancerologia uses this technique, but two questions arise from the medical-physicists and medical radio-oncologist: In accordance with clinical protocols, the conformal radiotherapy delivers a low dose to the adjacent healthy tissues. What experimental method exists that can prove with certainly the veracity of this affirmation?. And, Do the dosimetric simulation system calculate suitable the dose for each tissues?. Through thermoluminescent dosimetry and the use of a physical simulator,we measured the absorbed dose at the target volume and the adjacent tissues using conformal and conventional radiotherapy. We proved that organs such as the rectum and bladder, receiver a minor dose in conformal radiotherapy, hence reducing their mobility probability. In addition, the readings from the thermoluminescent dosimeters and the doses calculated by the ECLIPSE dosimetric system were compared, concluding that the patient's prescribed dose is effectively delivered as recommended by the quality control program in radiotherapy. (Author)

  13. Dosimetric verification of the intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Zou Huawei; Jia Mingxuan; Wu Rong; Xiao Fuda; Dong Xiaoqi

    2004-01-01

    Objective: To discuss the methods of the dosimetric verification in the intensity-modulated radiation therapy (IMRT) and insure correct execution of the IMRT planning in the clinical practice. Methods: The CMSFOCUS9200 inverse planning system was used to provide optimized 5-field IMRT treatment plans for the patients. A phantom was made from true water-equivalent material. The doses of the interesting points and isodose distributions of the interesting planes in the phantom were calculated using patients' treatment plan. The phantom was placed on the couch of the accelerator and was irradiated using the phantom's treatment planning data. The doses of interesting points were measured using a 0.23 cc chamber and the isodose distributions of interesting planes were measured using RIT 113 film dosimetry system in the phantom. The results were compared with those from calculation in planning system for verification. Results: The doses and isodose distributions measured by the chamber and the film were consistent with those predicted by the planning. The error between the measured dose and calculated dose in the interesting points was less than 3%. Conclusion: The dosimetric verification of IMRT is a reliable measure in the course of its implementation. (authors)

  14. Thermoluminescent Dosimeter as the Gamma Component of a Nuclear Accident Dosimeter; Utilisation du Dosimetre Thermoluminescent Comme Element Detecteur Gamma d'un Dosimetre pour les cas d'Accident Nucleaire; 0422 0415 0420 041c 0414 ; Los Detectores de Termoluminiscencia Como Elemento Gammametrico de un Dosimetro para Casos de Accidente Nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Handloser, J. S. [Edgerton, Germeshausen and Grier, Inc., Santa Barbara, CA (United States)

    1965-06-15

    Various types of gamma dosimeters have been employed as the gamma-measuring component of accident dosimeters. These have included various types of glass dosimeters, film, chemical dosimeters and polymerization dosimeters. The thermoluminescent dosimeter has notable advantages over these other types. The wide range of the thermoluminescent dosimeter permits it to be used both as a daily monitor for radiation protection purposes and as an accident dosimeter. This concept eliminates the need for special instrumentation for accident dosimeters and allows the well-calibrated instrumentation in daily use to be utilized in the accident dosimeter system. Commonly, the thermoluminescent dosimeter's inherent range is from 5 mr to 100 000 r, with a reproducibility of {+-} 10%. A single-type calcium fluoride dosimeter and associated readout equipment has been designed and manufactured to cover 5 mr to 5000 r. Readout of the dosimeter is accomplished by heating the phosphor and measuring the light output. Six decade readout instruments are available and completely automated systems have been designed. None of the readout equipment requires more than 20 seconds per dosimeter. Another advantage of the thermoluminescent dosimeter is the low neutron response. The neutron response will vary with the type of container and the type of phosphor. One type of calcium fluoride dosimeter has a neutron response of 0.27 x 10{sup -9} rad per n/cm{sup 2}. Two physical forms of the thermoluminescent dosimeter are considered. The first is an internally heated evacuated dosimeter contained in a glass envelope. This dosimeter is about 3/8-in diam.x 2 Vulgar-Fraction-One-Half -in long. The second type consists of a small-bore glass tube with the phosphor sealed inside. This dosimeter is 0.8-mm diam. x 6-mm long. Energy response correction shields have been designed for both types of dosimeter. (author) [French] L'auteur a employe divers types de cellules comme elements detecteurs des rayons gamma

  15. Analysis of dosimetric data of the national liquidator registry of Ukraine

    International Nuclear Information System (INIS)

    Chumak, V.; Bondarenko, A.

    1998-01-01

    The reliability of the Ukrainian national Chernobyl registry was assessed. The analysis of data of the individual doses of military Chernobyl clean-up workers suggested two possible scenarios leading to the unusual observed distribution: strong administrative pressure on the dosimetric service leading to falsification of data, or a strong dose management under conditions of unlimited man-power source. The daily dose rate distributions were found to comply very well with known regularities of occupational exposure, viz. the hybrid lognormal law for the military liquidators. Parameters of the distributions are consistent with a priori and experimental considerations. Thus, a strong dose management was probably exercised at the time of the clean-up; intentional distortion of the dose records is not very likely. This does not imply, though, that the dose records are very accurate. (P.A.)

  16. Dose reader of dosimetric foil; Czytnik dawki folii dozymetrycznej

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.; Strzalkowski, J.; Smolko, K.

    1997-12-31

    Read out the absorbance of a dosimetric foil is accomplished by two beam spectrophotometer. Such a solution makes possible the compensation of light source instabilities and ensures higher stability of the dose reader. The error of absorbance measurement caused by the instabilities does not exceed 0.0004 A. (author). 3 refs, 3 figs.

  17. Treatment of Non-Small Cell Lung Cancer Patients With Proton Beam-Based Stereotactic Body Radiotherapy: Dosimetric Comparison With Photon Plans Highlights Importance of Range Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Seco, Joao, E-mail: jseco@partners.org [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, MA (United States); Panahandeh, Hamid Reza [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, MA (United States); Westover, Kenneth [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, MA (United States); Harvard Radiation Oncology Program, Harvard Medical School, Boston, MA (United States); Adams, Judith; Willers, Henning [Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, MA (United States)

    2012-05-01

    Purpose: Proton beam radiotherapy has been proposed for use in stereotactic body radiotherapy (SBRT) for early-stage non-small-cell lung cancer. In the present study, we sought to analyze how the range uncertainties for protons might affect its therapeutic utility for SBRT. Methods and Materials: Ten patients with early-stage non-small-cell lung cancer received SBRT with two to three proton beams. The patients underwent repeat planning for photon SBRT, and the dose distributions to the normal and tumor tissues were compared with the proton plans. The dosimetric comparisons were performed within an operational definition of high- and low-dose regions representing volumes receiving >50% and <50% of the prescription dose, respectively. Results: In high-dose regions, the average volume receiving {>=}95% of the prescription dose was larger for proton than for photon SBRT (i.e., 46.5 cm{sup 3} vs. 33.5 cm{sup 3}; p = .009, respectively). The corresponding conformity indexes were 2.46 and 1.56. For tumors in close proximity to the chest wall, the chest wall volume receiving {>=}30 Gy was 7 cm{sup 3} larger for protons than for photons (p = .06). In low-dose regions, the lung volume receiving {>=}5 Gy and maximum esophagus dose were smaller for protons than for photons (p = .019 and p < .001, respectively). Conclusions: Protons generate larger high-dose regions than photons because of range uncertainties. This can result in nearby healthy organs (e.g., chest wall) receiving close to the prescription dose, at least when two to three beams are used, such as in our study. Therefore, future research should explore the benefit of using more than three beams to reduce the dose to nearby organs. Additionally, clinical subgroups should be identified that will benefit from proton SBRT.

  18. Correlation of dosimetric parameters obtained with the analytical anisotropic algorithm and toxicity of chest chemoradiation in lung carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cartier, Lysian; Auberdiac, Pierre; Khodri, Mustapha; Malkoun, Nadia [Departement de Radiotherapie, Institut de Cancerologie de la Loire, St-Priest en Jarez (France); Chargari, Cyrus [Service d' Oncologie Radiotherapie, Hopital d' Instruction des Armees du Val-de-Grace, Paris (France); Thorin, Julie [Departement de Sante Publique, Unite de Statistique, Institut de Cancerologie de la Loire, St-Priest en Jarez (France); Melis, Adrien [Departement d' Oncologie Medicale, Institut de Cancerologie de la Loire, St-Priest en Jarez (France); Talabard, Jean-Noeel; Laroche, Guy de [Departement de Radiotherapie, Institut de Cancerologie de la Loire, St-Priest en Jarez (France); Fournel, Pierre [Departement d' Oncologie Medicale, Institut de Cancerologie de la Loire, St-Priest en Jarez (France); Tiffet, Olivier [Service de Chirurgie Thoracique, Centre Hospitalier Universitaire de Saint Etienne, Saint Etienne (France); Schmitt, Thierry [Departement de Radiotherapie, Institut de Cancerologie de la Loire, St-Priest en Jarez (France); and others

    2012-07-01

    The purpose of this study was to analyze and revisit toxicity related to chest chemoradiotherapy and to correlate these side effects with dosimetric parameters obtained using analytical anisotropic algorithm (AAA) in locally unresectable advanced lung cancer. We retrospectively analyzed data from 47 lung cancer patients between 2005 and 2008. All received conformal 3D radiotherapy using high-energy linear accelerator plus concomitant chemotherapy. All treatment planning data were transferred into Eclipse 8.05 (Varian Medical Systems, Palo Alto, CA) and dosimetric calculations were performed using AAA. Thirty-three patients (70.2%) developed acute pneumopathy after radiotherapy (grades 1 and 2). One patient (2.1%) presented with grade 3 pneumopathy. Thirty-one (66%) presented with grades 1-2 lung fibrosis, and 1 patient presented with grade 3 lung fibrosis. Thirty-four patients (72.3%) developed grade 1-2 acute oesophagic toxicity. Four patients (8.5%) presented with grades 3 and 4 dysphagia, necessitating prolonged parenteral nutrition. Median prescribed dose was 64 Gy (range 50-74) with conventional fractionation (2 Gy per fraction). Dose-volume constraints were respected with a median V20 of 23.5% (maximum 34%) and a median V30 of 17% (maximum 25%). The median dose delivered to healthy contralateral lung was 13.1 Gy (maximum 18.1 Gy). At univariate analysis, larger planning target volume and V20 were significantly associated with the probability of grade {>=}2 radiation-induced pneumopathy (p = 0.022 and p = 0.017, respectively). No relation between oesophagic toxicity and clinical/dosimetric parameters could be established. Using AAA, the present results confirm the predictive value of the V20 for lung toxicity as already demonstrated with the conventional pencil beam convolution approach.

  19. Human respiratory tract model for radiological protection: A revision of the ICRP Dosimetric Model for the Respiratory System

    International Nuclear Information System (INIS)

    Bair, W.J.

    1989-01-01

    In 1984, the International Commission on Radiological Protection (ICRP) appointed a task group of Committee 2 to review and revise, as necessary, the ICRP Dosimetric Model for the Respiratory System. The model was originally published in 1966, modified slightly in Publication No. 19, and again in Publication No. 30 (in 1979). The task group concluded that research during the past 20 y suggested certain deficiencies in the ICRP Dosimetric Model for the Respiratory System. Research has also provided sufficient information for a revision of the model. The task group's approach has been to review, in depth, morphology and physiology of the respiratory tract; deposition of inhaled particles in the respiratory tract; clearance of deposited materials; and the nature and specific sites of damage to the respiratory tract caused by inhaled radioactive substances. This review has led to a redefinition of the regions of the respiratory tract for dosimetric purposes. The redefinition has a morphologic and physiological basis and is consistent with observed deposition and clearance of particles and with resultant pathology. Regions, as revised, are the extrathoracic (E-T) region, comprising the nasal and oral regions, the pharynx, larynx, and upper part of the trachea; the fast-clearing thoracic region (T[f]), comprising the remainder of the trachea and bronchi; and the slow-clearing thoracic region (T[s]), comprising the bronchioles, alveoli, and thoracic lymph nodes. A task group report will include models for calculating radiation doses to these regions of the respiratory tract following inhalation of representative alpha-, beta-, and gamma-emitting particulate and gaseous radionuclides. The models may be implemented as a package of computer codes available to a wide range of users

  20. Development of a dosimetric system for emergency situation involving person of the public

    International Nuclear Information System (INIS)

    Costa, Zelia Maria da

    1999-01-01

    A dosimetric system was developed for emergency situation based on electron spin resonance spectrometry (E.S.R.) and some materials such as tooth enamel, bovine bone, CaCO 3 and sugar as detector. The purpose of this work was to find common materials, which are both reliable and sensitive and make possible quickly to assess the absorbed dose. The research includes the collection and preparation of samples, the evaluation, treatment and interpretation of ESR signal and the procedure for dose reconstruction. The calibration of the dosemeter was performed using gamma radiation from a Co-60 source. The results obtained confirm the variability of the use of this system in case of an accident. (author)

  1. Dose assessment in patients undergoing lung examinations by computed tomography

    International Nuclear Information System (INIS)

    Gonzaga, Natalia B.; Silva, Teogenes A. da; Magalhaes, Marcos J.

    2011-01-01

    In the last fifteen years, the use of computed tomography (CT) has increased alongside other radiology technologies technologies. Its contribution has already achieved 34% in terms of doses undergone by patients. Radiation protection of patients submitted to CT examinations is based on the knowledge of internationally defined dosimetric quantities as the CT air kerma-length product (P K,L ) and weighted CT air kerma index (C w ). In Brazil, those dosimetric quantities are not routinely used and the optimization criteria are based only upon the MSAD - the average dose in multislices. In this work, the dosimetric quantities P K,L and C w were assessed by the CT Expo program for seven protocols used daily for lung examinations in adults with the use of Siemens and Philips scanners in Belo Horizonte. Results showed that P K,L values varied from 163 to 558 mGy.cm and the C w from 9.6 to 17.5 mGy. All results were found to be lower than the reference values internationally recommended by ICRP 87 and the European Community 16262 (30 mGy and 650 mGy.cm). The large dose ranges suggest that optimization of patient dose reduction is still possible without losses in the image quality and new reference dose levels could be recommended after a large survey to be carried out in the region. (author)

  2. Live Fire Range Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    None

    1993-08-01

    The Central Training Academy (CTA) is a DOE Headquarters Organization located in Albuquerque, New Mexico, with the mission to effectively and efficiently educate and train personnel involved in the protection of vital national security interests of DOE. The CTA Live Fire Range (LFR), where most of the firearms and tactical training occurs, is a complex separate from the main campus. The purpose of the proposed action is to expand the LFR to allow more options of implementing required training. The Department of Energy has prepared this Environmental Assessment (EA) for the proposed construction and operation of an expanded Live Fire Range Facility at the Central Training Academy in Albuquerque, New Mexico. Based on the analysis in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an environmental impact statement is not required and DOE is issuing this Finding of No Significant Impact (FONSI).

  3. Use of secondary phosphorescence for determination of the dose absorbed in dosimetric phosphors

    CERN Document Server

    Yaek, I V

    2002-01-01

    The measuring method of optically stimulated persistence (OSP) based on both the time division of the stimulating irradiation and luminescent response registration was applied for the radiation dosimetry. It was shown that the stimulation by the short-wave radiation crossing with spectrum of the dosimetric phosphor is possible. The spectrum of the stimulation of industry dosimetric phosphors was measured. The characteristics of the OSP registration for the phosphors which has manganese Mn sup 2 sup + as the activator is considered. Decay time of inner center luminescence is 40-50 ms. This method is used for the dosimetry of the natural quartzes to determine their age.

  4. Dosimetric verification for primary focal hypermetabolism of nasopharyngeal carcinoma patients treated with dynamic intensity-modulated radiation therapy.

    Science.gov (United States)

    Xin, Yong; Wang, Jia-Yang; Li, Liang; Tang, Tian-You; Liu, Gui-Hong; Wang, Jian-She; Xu, Yu-Mei; Chen, Yong; Zhang, Long-Zhen

    2012-01-01

    To make sure the feasibility with (18F)FDG PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and (18F)FDG PET/CT). The dose distributions of the various regional were realized by SMART. The absolute mean errors of interest area were 2.39%±0.66 using 0.6 cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

  5. Patient-specific dosimetric endpoints based treatment plan quality control in radiotherapy

    International Nuclear Information System (INIS)

    Song, Ting; Zhou, Linghong; Staub, David; Chen, Mingli; Lu, Weiguo; Tian, Zhen; Jia, Xun; Li, Yongbao; Jiang, Steve B; Gu, Xuejun

    2015-01-01

    In intensity modulated radiotherapy (IMRT), the optimal plan for each patient is specific due to unique patient anatomy. To achieve such a plan, patient-specific dosimetric goals reflecting each patient’s unique anatomy should be defined and adopted in the treatment planning procedure for plan quality control. This study is to develop such a personalized treatment plan quality control tool by predicting patient-specific dosimetric endpoints (DEs). The incorporation of patient specific DEs is realized by a multi-OAR geometry-dosimetry model, capable of predicting optimal DEs based on the individual patient’s geometry. The overall quality of a treatment plan is then judged with a numerical treatment plan quality indicator and characterized as optimal or suboptimal. Taking advantage of clinically available prostate volumetric modulated arc therapy (VMAT) treatment plans, we built and evaluated our proposed plan quality control tool. Using our developed tool, six of twenty evaluated plans were identified as sub-optimal plans. After plan re-optimization, these suboptimal plans achieved better OAR dose sparing without sacrificing the PTV coverage, and the dosimetric endpoints of the re-optimized plans agreed well with the model predicted values, which validate the predictability of the proposed tool. In conclusion, the developed tool is able to accurately predict optimally achievable DEs of multiple OARs, identify suboptimal plans, and guide plan optimization. It is a useful tool for achieving patient-specific treatment plan quality control. (paper)

  6. Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jiahua [Department of Physics, University of Adelaide, Adelaide, SA 5005 (Australia); Penfold, Scott N., E-mail: scott.penfold@adelaide.edu.au [Department of Physics, University of Adelaide, Adelaide, SA 5005, Australia and Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000 (Australia)

    2016-06-15

    Purpose: The accuracy of proton dose calculation is dependent on the ability to correctly characterize patient tissues with medical imaging. The most common method is to correlate computed tomography (CT) numbers obtained via single-energy CT (SECT) with proton stopping power ratio (SPR). CT numbers, however, cannot discriminate between a change in mass density and change in chemical composition of patient tissues. This limitation can have consequences on SPR calibration accuracy. Dual-energy CT (DECT) is receiving increasing interest as an alternative imaging modality for proton therapy treatment planning due to its ability to discriminate between changes in patient density and chemical composition. In the current work we use a phantom of known composition to demonstrate the dosimetric advantages of proton therapy treatment planning with DECT over SECT. Methods: A phantom of known composition was scanned with a clinical SECT radiotherapy CT-simulator. The phantom was rescanned at a lower X-ray tube potential to generate a complimentary DECT image set. A set of reference materials similar in composition to the phantom was used to perform a stoichiometric calibration of SECT CT number to proton SPRs. The same set of reference materials was used to perform a DECT stoichiometric calibration based on effective atomic number. The known composition of the phantom was used to assess the accuracy of SPR calibration with SECT and DECT. Intensity modulated proton therapy (IMPT) treatment plans were generated with the SECT and DECT image sets to assess the dosimetric effect of the imaging modality. Isodose difference maps and root mean square (RMS) error calculations were used to assess dose calculation accuracy. Results: SPR calculation accuracy was found to be superior, on average, with DECT relative to SECT. Maximum errors of 12.8% and 2.2% were found for SECT and DECT, respectively. Qualitative examination of dose difference maps clearly showed the dosimetric advantages

  7. Studies on γ-ray induced structural changes in Nd{sup 3+} doped lead alumino silicate glasses by means of thermoluminescence for dosimetric applications in high dose ranges

    Energy Technology Data Exchange (ETDEWEB)

    Sundara Rao, M. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India); Gandhi, Y. [Department of Physics, Kakani Venkata Ratnam College, Nandigama 521 185, A.P. (India); Sanyal, Bhaskar [Food Technology Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Bhargavi, K. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India); Piasecki, M. [Institute of Physics, J. Dlugosz University, Ul. Armii Krajowej 13/15, 42-201 Czestochowa (Poland); Veeraiah, N., E-mail: nvr8@rediffmail.com [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India)

    2014-12-15

    Graphical abstract: TL glow curves of PbO–SiO{sub 2}:Nd{sup 3+} glasses mixed with different concentrations of Al{sub 2}O{sub 3} exposed to γ-rays of dose 5.0 kGy. - Highlights: • TL studies of Nd{sup 3+} ions doped lead alumino silicate glasses were carried out. • Highest TL output was observed in the glasses mixed with 10 mol% of Al{sub 2}O{sub 3}. • Different mechanisms responsible for TL emission were discussed. • Near linearity of the dose response was observed in the dose range of 1.0–3.0 kGy. • These glasses may be useful as dosimeters in processing perishable food commodities. - Abstract: Thermoluminescence (TL) studies on PbO–Al{sub 2}O{sub 3}–SiO{sub 2}:Nd{sup 3+} glasses mixed with varying concentrations of Al{sub 2}O{sub 3} exposed to γ-rays of dose in the range 0–5.0 kGy were carried out. The TL emission exhibited a dosimetric peak at about 185 °C. The TL output under the glow peak increased with increasing Al{sub 2}O{sub 3} and also with the γ-ray dose. The mechanisms responsible for TL emission and enhancement of TL output with increase in the concentration of Al{sub 2}O{sub 3} were quantitatively discussed in terms of induced structural defects in the vicinity of Nd{sup 3+} ions due to interaction of γ-rays with the glass network in the scenario of varying concentration of Al{sub 2}O{sub 3}. The dose response of these glass samples exhibited linear behavior in the medium dose range viz., 1.0–3.0 kGy. Finally, it is concluded that the glass containing the highest concentration of Al{sub 2}O{sub 3} exhibits high TL output and such glasses are useful for dosimetry in the range 1.0–3.0 kGy and hence these glasses may be useful for dosimetry in such high range of doses required for commercial radiation processing of perishable food commodities to extend their shelf-lives.

  8. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation

    International Nuclear Information System (INIS)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M.; Schreck, M.; Cruz Z, E.

    2005-01-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 μm thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH 4 /H 2 and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr 90 / Y 90 ) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  9. BeOSL system for personal dosimetry : dosimetric characteristics and practical application

    International Nuclear Information System (INIS)

    Mende, E.

    2015-10-01

    Full text: BeOSL system of Dosimetric s is very easy to use, assimilate and maintain. Our dosimeter defines a milestone in the supervision of personal equivalent dose of Hp (10) and Hp (0.07) it covers the range of total energy of 16 KeV to 10 MeV. For this energy range is exceptional in its energy dependence for official personal dosimetry. The BeOSL system consists of two modules, one of them is the BeOSL reader that measures the radiation exposure using the latest technology, optically stimulated luminescence (OSL). The reading is extremely fast; it does not require consumables such as nitrogen or other. The detector material is beryllium oxide (Be O); this is an OSL material tissue equivalent and therefore is ideal for personal dosimetry. The BeOSL technology allows multiple readings of the dosimeter (re-read) to verify the dose or archive the dosimeter. One of the biggest advantages of BeOSL system is its modular concept allows the system to run as a manual solution or as a complete automated robotic system, which can be filled with up to 5,000 dosimeters as bulk cargo. (Author)

  10. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Foroudi Farshad

    2012-07-01

    Full Text Available Abstract Background To compare 3 Dimensional Conformal radiotherapy (3D-CRT with Intensity Modulated Radiotherapy (IMRT with Volumetric-Modulated Arc Therapy (VMAT for bladder cancer. Methods Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Results Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293 for 3D-CRT; 824 (range 641–1083 for IMRT; and 403 (range 333–489 for VMAT (P  Conclusions VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours.

  11. Quantitative dosimetric assessment for effect of gold nanoparticles as contrast media on radiotherapy planning

    International Nuclear Information System (INIS)

    Tu, Shu-Ju; Yang, Pei-Ying; Hong, Ji-Hong; Lo, Ching-Jung

    2013-01-01

    In CT planning for radiation therapy, patients may be asked to have a medical procedure of contrast agent (CA) administration as required by their physicians. CA media improve quality of CT images and assist radiation oncologists in delineation of the target or organs with accuracy. However, dosimetric discrepancy may occur between scenarios in which CA media are present in CT planning and absent in treatment delivery. In recent preclinical experiments of small animals, gold nanoparticles (AuNPs) have been identified as an excellent contrast material of x-ray imaging. In this work, we quantitatively evaluate the effect of AuNPs to be used as a potential material of contrast enhancement in radiotherapy planning with an analytical phantom and clinical case. Conray 60, an iodine-based product for contrast enhancement in clinical uses, is included as a comparison. Other additional variables such as different concentrations of CA media, radiation delivery techniques and dose calculation algorithms are included. We consider 1-field AP, 4-field box, 7-field intensity modulated radiation therapy (IMRT) and a recent technique of volumetric modulated arc therapy (VMAT). CA media of AuNPs (Conray 60) with concentrations of 10%, 20%, 30%, 40% and 50% containing 28.2, 56.4, 84.6, 112.8 and 141.0 mg of gold (iodine) per mL were prepared prior to CT scanning. A virtual phantom with a target where nanoparticle media are loaded and clinical case of gastric lymphoma in which the Conray 60 media were given to the patient prior to the CT planning are included for the study. Compared to Conray 60 media with concentration of 10%/50%, Hounsfield units for AuNP media of 10%/50% are 322/1608 higher due to the fact that atomic number of Au (Z=79) is larger than I (Z=53). In consequence, dosimetric discrepancy of AuNPs is magnified between presence and absence of contrast media. It was found in the phantom study that percent dose differences between presence and absence of CA media may be

  12. Monte Carlo generation of dosimetric parameters for eye plaque dosimetry

    International Nuclear Information System (INIS)

    Cutajar, D.L.; Green, J.A.; Guatelli, S.; Rosenfeld, A.B.

    2010-01-01

    Full text: The Centre for Medical Radiation Physics have undertaken the dcvelopment of a quality assurance tool, using silicon pixelated detectors, for the calibration of eye plaques prior to insertion. Dosimetric software to correlate the measured and predicted dose rates has been constructed. The dosimetric parameters within the software, for both 1-125 and Ru-I 06 based eye plaques, were optimised using the Geant4 Monte Carlo toolkit. Methods For 1-125 based plaques, an novel application was developed to generate TG-43 parameters for any seed input. TG-43 parameters were generated for an Oncura model 6711 seed, with data points every millimetre up to 25 mm in the radial direction, and every 5 degrees in polar angle, and correlated to published data. For the Ru106 based plaques, an application was developed to generate dose rates about a Bebig model CCD plaque. Toroids were used to score the deposited dose, taking advantage of the cylindrical symmetry of the plaque, with radii in millimetre increments up to 25 mm, and depth from the plaque surface in millimetre increments up to 25 mm. Results TheTG43 parameters generated for the 6711 seed correlate well with published TG43 data at the given intervals, with radial dose function within 3%, and anisotropy function within 5% for angles greater than 30 degrees. The Ru-l 06 plaque data correlated well with the Bebig protocol of measurement. Conclusion Geant4 is a useful Monte Carlo tool for the generation of dosimetric data for eye plaque dosimetry. which may improve the quality assurance of eye plaque treatment. (author)

  13. Medical linear accelerator mounted mini-beam collimator: design, fabrication and dosimetric characterization.

    Science.gov (United States)

    Cranmer-Sargison, G; Crewson, C; Davis, W M; Sidhu, N P; Kundapur, V

    2015-09-07

    The goal of this work was to design, build and experimentally characterize a linear accelerator mounted mini-beam collimator for use at a nominal 6 MV beam energy. Monte Carlo simulation was used in the design and dosimetric characterization of a compact mini-beam collimator assembly mounted to a medical linear accelerator. After fabrication, experimental mini-beam dose profiles and central axis relative output were measured and the results used to validate the simulation data. The simulation data was then used to establish traceability back to an established dosimetric code of practice. The Monte Carlo simulation work revealed that changes in collimator blade width have a greater influence on the valley-to-peak dose ratio than do changes in blade height. There was good agreement between the modeled and measured profile data, with the exception of small differences on either side of the central peak dose. These differences were found to be systematic across all depths and result from limitations associated with the collimator fabrication. Experimental mini-beam relative output and simulation data agreed to better than ± 2.0%, which is well within the level of uncertainty required for dosimetric traceability of non-standard field geometries. A mini-beam collimator has now been designed, built and experimentally characterized for use with a commercial linear accelerator operated at a nominal 6 MV beam energy.

  14. Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

    Science.gov (United States)

    Almansa, Julio F; Guerrero, Rafael; Torres, Javier; Lallena, Antonio M

    60 Co sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is ∼0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of 60 Co, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Dosimetric optimization approach for activities of metal plutonium elaboration by calciothermy; Demarche d'optimisation dosimetrique des activites d'elaboration du plutonium metal par calciothermie

    Energy Technology Data Exchange (ETDEWEB)

    Crovisier, Ph.; Brunetti, L.; Jourde, S.; Piot, J.; Valier Brasier, P. [CEA/DAMNA/DSTA - Service de Protection contre les Rayonnements- Centre de Valduc - 21120 Is sur Tille (France)

    2008-07-01

    The authors present the activities performed within a new unit of a plutonium pyro-chemistry laboratory, report a dosimetric assessment of workstation in this unit, compare the data with those obtained with the previous installation, and report a study of the neutronic efficiency of biological protection shields (measurements of neutron spectra)

  16. Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo method

    International Nuclear Information System (INIS)

    Oliveira, Tiago Batista de

    2016-01-01

    Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, an IPEN seed and the 30 x 30 x 30cm 3 phantom filled with water were modeled to simulate the dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty. (author)

  17. Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification.

    Science.gov (United States)

    Jin, X; Yan, H; Han, C; Zhou, Y; Yi, J; Xie, C

    2015-03-01

    To investigate comparatively the percentage gamma passing rate (%GP) of two-dimensional (2D) and three-dimensional (3D) pre-treatment volumetric modulated arc therapy (VMAT) dosimetric verification and their correlation and sensitivity with percentage dosimetric errors (%DE). %GP of 2D and 3D pre-treatment VMAT quality assurance (QA) with different acceptance criteria was obtained by ArcCHECK® (Sun Nuclear Corporation, Melbourne, FL) for 20 patients with nasopharyngeal cancer (NPC) and 20 patients with oesophageal cancer. %DE were calculated from planned dose-volume histogram (DVH) and patients' predicted DVH calculated by 3DVH® software (Sun Nuclear Corporation). Correlation and sensitivity between %GP and %DE were investigated using Pearson's correlation coefficient (r) and receiver operating characteristics (ROCs). Relatively higher %DE on some DVH-based metrics were observed for both patients with NPC and oesophageal cancer. Except for 2%/2 mm criterion, the average %GPs for all patients undergoing VMAT were acceptable with average rates of 97.11% ± 1.54% and 97.39% ± 1.37% for 2D and 3D 3%/3 mm criteria, respectively. The number of correlations for 3D was higher than that for 2D (21 vs 8). However, the general correlation was still poor for all the analysed metrics (9 out of 26 for 3D 3%/3 mm criterion). The average area under the curve (AUC) of ROCs was 0.66 ± 0.12 and 0.71 ± 0.21 for 2D and 3D evaluations, respectively. There is a lack of correlation between %GP and %DE for both 2D and 3D pre-treatment VMAT dosimetric evaluation. DVH-based dose metrics evaluation obtained from 3DVH will provide more useful analysis. Correlation and sensitivity of %GP with %DE for VMAT QA were studied for the first time.

  18. Dosimetric evaluation of proton stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Min, Byung Jun; Shin, Dong Ho; Yoo, Seung Hoon; Jeong, Hojin; Lee, Se Byeong

    2011-01-01

    Surgical excision, conventional external radiotherapy, and chemotherapy could prolong survival in patients with small intracranial tumors. However, surgical excision for meningiomas located in the region of the base of skull or re-resection is often difficult. Moreover, treatment is needed for patients with recurrent tumors or postoperative residual tumors. Conventional external radiotherapy is popular and has significantly increased for treating brain tumors. Stereotactic radiosurgery is an effective alternative treatment technique to microsurgical resection such as benign brain tumor or vestibular Schwannomas. In general, the dose to OAR of 3D conformal plan is lower than that of conformal arc and dynamic conformal arc plans. However, any of OARs was not reached to tolerance dose. Although mean dose of the healthy brain tissue for 3D conformal plan was slightly higher than that of arc plans, the doses of the healthy brain tissue at V10 and V20 were significantly low for dynamic conformal arc plan. The dosimetric differences were the greatest at lower doses. In contrast, 3D conformal plan was better spare at higher doses. In this study, a dosimetric evaluation of proton stereotactic radiosurgery for brain lesion tumors was using fixed and arc beams. A brass block fitted to the PTV structure was modeled for dynamic conformal collimator. Although all treatment plans offer a very good coverage of the PTV, we found that proton arc plans had significantly better conformity to the PTV than static 3D conformal plan. The V20 dose of normal brain for dynamic conformal arc therapy is dramatically reduced compare to those for other therapy techniques.

  19. Dosimetric systems developed in Brazil for the radiation processes quality control

    International Nuclear Information System (INIS)

    Galante, Ana Maria Sisti; Campos, Leticia Lucente

    2011-01-01

    In order to apply new technologies to the industrial processing of materials aiming economy, efficiency, speed and high quality, ionizing radiation has been used in medicine, archaeology, chemistry, food preservation and other areas. For this reason, the dosimetry area looks for improve current dosimeters and develop new materials for application on quality control of these processes. In Brazil, the research in the dosimetry area occurs with great speed providing many different dosimetric systems. The chemical dosimetry is the most used technique in routine dosimetry, which requires fast and accurate responses. This technique involves determination of absorbed dose by measuring chemical changes radiation induced in the materials. Different dosimetric systems were developed at IPEN for application on radiation process quality and all of them present excellent results; the low cost of these materials allows a more effective dose control, therefore, a larger area or volume can be monitored. (author).

  20. Dosimetric Analysis of Radiation-induced Gastric Bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Mary, E-mail: maryfeng@umich.edu [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Normolle, Daniel [Department of Biostatistics, University of Pittsburgh, Pittsburgh, Pennsylvania (United States); Pan, Charlie C. [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Dawson, Laura A. [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Amarnath, Sudha [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Ensminger, William D. [Department of Internal Medicine, Division of Hematology Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States); Lawrence, Theodore S.; Ten Haken, Randall K. [Department of Radiation Oncology, University of Michigan School of Medicine, Ann Arbor, Michigan (United States)

    2012-09-01

    Purpose: Radiation-induced gastric bleeding has been poorly understood. In this study, we described dosimetric predictors for gastric bleeding after fractionated radiation therapy. Methods and Materials: The records of 139 sequential patients treated with 3-dimensional conformal radiation therapy (3D-CRT) for intrahepatic malignancies were reviewed. Median follow-up was 7.4 months. The parameters of a Lyman normal tissue complication probability (NTCP) model for the occurrence of {>=}grade 3 gastric bleed, adjusted for cirrhosis, were fitted to the data. The principle of maximum likelihood was used to estimate parameters for NTCP models. Results: Sixteen of 116 evaluable patients (14%) developed gastric bleeds at a median time of 4.0 months (mean, 6.5 months; range, 2.1-28.3 months) following completion of RT. The median and mean maximum doses to the stomach were 61 and 63 Gy (range, 46-86 Gy), respectively, after biocorrection of each part of the 3D dose distributions to equivalent 2-Gy daily fractions. The Lyman NTCP model with parameters adjusted for cirrhosis predicted gastric bleed. Best-fit Lyman NTCP model parameters were n=0.10 and m=0.21 and with TD{sub 50} (normal) = 56 Gy and TD{sub 50} (cirrhosis) = 22 Gy. The low n value is consistent with the importance of maximum dose; a lower TD{sub 50} value for the cirrhosis patients points out their greater sensitivity. Conclusions: This study demonstrates that the Lyman NTCP model has utility for predicting gastric bleeding and that the presence of cirrhosis greatly increases this risk. These findings should facilitate the design of future clinical trials involving high-dose upper abdominal radiation.

  1. Dosimetric Analysis of Radiation-induced Gastric Bleeding

    International Nuclear Information System (INIS)

    Feng, Mary; Normolle, Daniel; Pan, Charlie C.; Dawson, Laura A.; Amarnath, Sudha; Ensminger, William D.; Lawrence, Theodore S.; Ten Haken, Randall K.

    2012-01-01

    Purpose: Radiation-induced gastric bleeding has been poorly understood. In this study, we described dosimetric predictors for gastric bleeding after fractionated radiation therapy. Methods and Materials: The records of 139 sequential patients treated with 3-dimensional conformal radiation therapy (3D-CRT) for intrahepatic malignancies were reviewed. Median follow-up was 7.4 months. The parameters of a Lyman normal tissue complication probability (NTCP) model for the occurrence of ≥grade 3 gastric bleed, adjusted for cirrhosis, were fitted to the data. The principle of maximum likelihood was used to estimate parameters for NTCP models. Results: Sixteen of 116 evaluable patients (14%) developed gastric bleeds at a median time of 4.0 months (mean, 6.5 months; range, 2.1-28.3 months) following completion of RT. The median and mean maximum doses to the stomach were 61 and 63 Gy (range, 46-86 Gy), respectively, after biocorrection of each part of the 3D dose distributions to equivalent 2-Gy daily fractions. The Lyman NTCP model with parameters adjusted for cirrhosis predicted gastric bleed. Best-fit Lyman NTCP model parameters were n=0.10 and m=0.21 and with TD 50 (normal) = 56 Gy and TD 50 (cirrhosis) = 22 Gy. The low n value is consistent with the importance of maximum dose; a lower TD 50 value for the cirrhosis patients points out their greater sensitivity. Conclusions: This study demonstrates that the Lyman NTCP model has utility for predicting gastric bleeding and that the presence of cirrhosis greatly increases this risk. These findings should facilitate the design of future clinical trials involving high-dose upper abdominal radiation.

  2. SU-E-T-365: Dosimetric Impact of Dental Amalgam CT Image Artifacts On IMRT and VMAT Head and Neck Plans

    Energy Technology Data Exchange (ETDEWEB)

    Cao, N; Young, L; Parvathaneni, U; Liao, J; Richard, P; Ford, E; Sandison, G [University of Washington, Department of Radiation Oncology, Seattle, WA (United States)

    2014-06-01

    Purpose: The presence of high density dental amalgam in patient CT image data sets causes dose calculation errors for head and neck (HN) treatment planning. This study assesses and compares dosimetric variations in IMRT and VMAT treatment plans due to dental artifacts. Methods: Sixteen HN patients with similar treatment sites (oropharynx), tumor volume and extensive dental artifacts were divided into two groups: IMRT (n=8, 6 to 9 beams) and VMAT (n=8, 2 arcs with 352° rotation). All cases were planned with the Pinnacle 9.2 treatment planning software using the collapsed cone convolution superposition algorithm and a range of prescription dose from 60 to 72Gy. Two different treatment plans were produced, each based on one of two image sets: (a)uncorrected; (b)dental artifacts density overridden (set to 1.0g/cm{sup 3}). Differences between the two treatment plans for each of the IMRT and VMAT techniques were quantified by the following dosimetric parameters: maximum point dose, maximum spinal cord and brainstem dose, mean left and right parotid dose, and PTV coverage (V95%Rx). Average differences generated for these dosimetric parameters were compared between IMRT and VMAT plans. Results: The average absolute dose differences (plan a minus plan b) for the VMAT and IMRT techniques, respectively, caused by dental artifacts were: 2.2±3.3cGy vs. 37.6±57.5cGy (maximum point dose, P=0.15); 1.2±0.9cGy vs. 7.9±6.7cGy (maximum spinal cord dose, P=0.026); 2.2±2.4cGy vs. 12.1±13.0cGy (maximum brainstem dose, P=0.077); 0.9±1.1cGy vs. 4.1±3.5cGy (mean left parotid dose, P=0.038); 0.9±0.8cGy vs. 7.8±11.9cGy (mean right parotid dose, P=0.136); 0.021%±0.014% vs. 0.803%±1.44% (PTV coverage, P=0.17). Conclusion: For the HN plans studied, dental artifacts demonstrated a greater dose calculation error for IMRT plans compared to VMAT plans. Rotational arcs appear on the average to compensate dose calculation errors induced by dental artifacts. Thus, compared to VMAT, density

  3. Postoperative telegammatherapy of breast cancer (Dosimetric studies)

    Energy Technology Data Exchange (ETDEWEB)

    Todorov, J; Mitrov, G [Nauchno-Izsledovatelski Onkologichen Inst., Sofia (Bulgaria); Konstantinov, B; Dobrev, D [Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya

    1977-01-01

    The method employed for postoperative radiation therapy of breast cancer at the Radiologic Clinic of the Medical Academy in Sofia is described. Results are reported and discussed of dosimetric studies carried out with the T-100 on heterogeneous tissue-equivalent Rando phantom for dose distributions in the regional lymph basin and the underlying tissues and organs. The results show coincidence between calculated and measured doses in the regional lymph basin and the thoracic wall. It was demonstrated that maximal radiation loading (3600 to 5500 rad) occurs in the apical and the hilar lung area.

  4. Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.

  5. Comparison of Panasonic’s Dosimetric System with Gamma-31 Dosimeters

    Directory of Open Access Journals (Sweden)

    Paweł Urban

    2013-01-01

    Full Text Available Equipment being used in medical or industrial institutions is often a source of ionizing radiation with different energies and types, which complicates the detection and assessment of doses. Up until now, for dosimetric measurements of ionizing radiation, Gamma-31 dosimeters have been used in the Central Mining Institute for many years. Now, this system will be expanded by a Panasonic system, for which measurement procedures were developed and comparisons with other dosimeters were held. The method is based on a four-element dosimeters UD-802 Panasonic equipped with CaSO and LiBO detectors additionally sheltered by filters of different surface mass. The use of UD-802 dosimeters, in contrast to Gamma-31 dosimeters, permits measuring radiation doses in a different range of photon energy. Consequently, it is possible to obtain a more accurate analysis of the hazards caused by gamma radiation in underground mines. The publication includes a description of the dosimetry system and presents the results of measurements conducted by means of both types of dosimeters. In order to verify the correctness of the indications of the new dosimetry system a series of measurements were carried out, which allowed examining the behaviour of the dosimeters under different environmental conditions. As a place of exposure, the selected laboratories in the Silesian Centre for Environmental Radiometry were chosen, where the work is connected with (TENORM and equipment producing ionizing radiation or containing sources of this type of radiation. Moreover, to observe the dosimeters behaviour in difficult environmental conditions, they were exposed in water treatment plants and an underground potassium salt mine.

  6. A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

    International Nuclear Information System (INIS)

    Foroudi, Farshad; Kron, Tomas; Wilson, Lesley; Bressel, Mathias; Haworth, Annette; Hornby, Colin; Pham, Daniel; Cramb, Jim; Gill, Suki; Tai, Keen Hun

    2012-01-01

    To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours

  7. Technical and dosimetric aspects of quality control in mammography

    International Nuclear Information System (INIS)

    Zoetelief, J.; Wit, N.J.P. de; Broerse, J.J.

    1989-01-01

    Before screening programmes using mammography are implemented, a cost benefit analysis has to be made and quality-control programme for the technical and dosimetric aspects adopted, including daily checks on film processing and total mammography procedure (radiography of a reference phantom, for which the average density, limiting value ± 0.20%, and focal charge is determined and which allows assessment of physical image quality) The installation of a MAs meter is essential for daily checks and can be used for determination of absorbed dose. Accurate determination of tube voltage (limiting value ±0.5 kV) is essential in regard to absorbed dose variations. Focal spot size should be measured rather than relying on the value specified by the manufacturer. The determination of the focal charge (mAs) value for actual radiographs of female breasts combined with a measurement of compressed breast thickness provides information on absorbed dose values for actual radiographs. An approximately 50 mm thick poly(methyl methacrylate) phantom can be used for determination of absorbed dose in mammography. (author)

  8. Influence of lucite phantoms on calibration of dosimetric pens

    International Nuclear Information System (INIS)

    Oliveira, E.C.; Xavier, M.; Caldas, L.E.V.

    1992-01-01

    Dosimetrical pens were studied for the answer repetition and were tested in gamma radiation fields ( 60 Co and 137 Cs) in air and in front of a lucite phantom, obtaining a backscattering contribution. The medium backscattering factors were 1,053 and 1,108 for respectively 60 Co and 137 Cs. The pens were placed behind the phantom for verifying the radiation attenuation. (C.G.C.)

  9. Luxol Fast Blue as a dosimetric material for industrial radiation processes

    International Nuclear Information System (INIS)

    Rushdi, M.A.H.; Beshir, W.B; Abdel-Fattah, A.A; Soliman, Y.S

    2015-01-01

    Using of polyvinyl butyral (PVB) film containing loxul fast blue (LFB) dye, thin films were prepared. Upon irradiation these films undergo a gradual change in color. Optical density change was analyzed spectrophotometrically at the maximum of the absorption band peaking at 421 nm. The useful dose range of film dosimeter response was seen from 0.5 to 50 kGy with (r2 = 0.999). Effects of the dosimetric parameters such as relative humidity and post-irradiation storage in dark and indirect daylight conditions on dosimeters performance were discussed. Addition studies have been done to evaluate the film dosimeter behavior at different energy regions including the mass energy absorption coefficient and mass stopping power dependence of the system. The effective atomic number and the radiation chemical yield for the film dosimeter were determined. The uncertainty budget for high doses has obtained from the measurement with value of 4.86% at 2σ confidence level.

  10. Radioecological and dosimetric consequences of the Chernobyl accident in France

    International Nuclear Information System (INIS)

    Renaud, Ph.; Beaugelin, K.; Maubert, H.; Ledenvic, Ph.

    1997-11-01

    This study has as objective a survey of the radioecological and dosimetric consequences of the Chernobyl accident in France, as well as a prognosis for the years to come. It was requested by the Direction of Nuclear Installation Safety (DSIN) in relation to different organisms which effected measurements after this accident. It is based on the use of combined results of measurements and modelling by means of the code ASTRAL developed at IPSN. Various measurements obtained from five authorities and institutions, were made available, such as: activity of air and water, soil, processed food, agricultural and natural products. However, to achieve the survey still a modelling is needed. ASTRAL is a code for evaluating the ecological consequences of an accident. It allows establishing the correspondence between the soil Remnant Surface Activities (RSA, in Bq.m -2 ), the activity concentration of the agricultural production and the individual and collective doses resulting from external and internal exposures (due to inhalation and ingestion of contaminated nurture). The results of principal synthesis documents on the Chernobyl accident and its consequences were also used. The report is structured in nine sections, as follows: 1.Introduction; 2.Objective and methodology; 3.Characterization of radioactive depositions; 4;Remnant surface activities; 5.Contamination of agricultural products and foods; 6.Contamination of natural, semi-natural products and of drinking water; 7.Dosimetric evaluations; 8.Proposals for the environmental surveillance; 9.Conclusion. Finally, after ten years, one concludes that at present the dosimetric consequences of the Chernobyl accident in France were rather limited. For the period 1986-2046 the average individual effective dose estimated for the most struck zone is lower than 1500 μSv, which represents almost 1% of the average natural exposure for the same period. At present, the cesium 137 levels are at often inferior to those recorded before

  11. Determination of dosimetric quantities in pediatric abdominal computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Jornada, Tiago da Silva [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostipo por Imagem; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-09-15

    Objective: aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: the study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (C{sub W}), but the differences were relevant in values for volumetric air kerma index (C{sub VOL}), air kerma-length product (P{sub KL,CT}) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, P{sub KL,CT} and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. (author)

  12. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    Science.gov (United States)

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  13. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  14. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  15. Study on the neutron dosimetric characteristics of Tissue Equivalent Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Nunomiya, T.; Kim, E.; Kurosawa, T.; Taniguchi, S.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Tsujimura, N.; Momose, T.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Environment and Safety Division, Tokai Works, Tokai, Ibaraki (Japan)

    1999-03-01

    The neutron dosimetric characteristics of TEPC (Tissue Equivalent Proportional Counter) has been investigated under a cooperative study between Tohoku University and JNC since 1997. This TEPC is a spherical, large volume, single-wire proportional counter (the model LETSW-5, manufactured by Far West Technology, Inc.) and filled with a tissue equivalent gas in a spherical detector of the A-150 tissue equivalent plastic. The TEPC can measure the spectra of absorbed dose in LET and easily estimate the tissue equivalent dose to neutron. This report summarizes the dosimetric characteristics of TEPC to the monoenergetic neutrons with energy from 8 keV to 15 MeV. It is found that TEPC can estimate the ambient dose equivalent, H*(10), with an accuracy from 0.9 to 2 to the neutron above 0.25 MeV and TEPC has a good counting efficiency enough to measure neutron doses with low dose rate at the stray neutron fields. (author)

  16. Dosimetric tests for treatment planning commissioning in 3DCRT; Testes dosimetricos para comissionamento de sistemas de planejamento em radioterapia 3DCRT

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Leandro R.; Pieri, Karen; Silva, Marco A.; Santos, Gabriela R.; Sales, Camila P.; Rubo, Rodrigo A.; Nakandakari, Marcos V.N.; Cunha, Ana Paula V; Santos, Caroline Z.; Rodrigues, Laura N.; Furnari, Laura, E-mail: leandrorg11@hotmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    2012-12-15

    The radiotherapy evolution from 2D treatments to 3D conformal treatments was possible after the advent the treatment planning systems commercially available and tridimensional images techniques like computed tomography. These systems have tools that allow delineate anatomical structures from tomographic images. Calculations dose tools allow the planner evaluate the dose received in the anatomical structures. When these systems are acquired or an upgrade is made many dosimetric and non-dosimetric tests need to be performed to know the system limitations and correct functioning and to verify the correct dosimetric data insertion. This study was based in International Atomic Energy Agency protocols, Task Groups documents from American Association of Physics in Medicine, and other papers. A dosimetric test set was done to commissioning the Eclipse 10.0.28 (Varian Medical Systems) treatments planning system This version has two photon calculation algorithm (Pencil Beam Convolution and Analytical Anisotropic Algorithm – AAA) and Gaussian Pencil Beam algorithm for electron beams. However, tests for AAA it was not performed. In this study was possible to conclude that the dosimetric data was correctly added in the treatment planning system. Some results allowed to understand the algorithm limitations to calculate dose distributions in specifics situations, that was not clinically relevant in our routine. (author)

  17. A national dosimetric audit of IMRT

    International Nuclear Information System (INIS)

    Budgell, Geoff; Berresford, Joe; Trainer, Michael; Bradshaw, Ellie; Sharpe, Peter; Williams, Peter

    2011-01-01

    Background and purpose: A dosimetric audit of IMRT has been carried out within the UK between June 2009 and March 2010 in order to provide an independent check of safe implementation and to identify problems in the modelling and delivery of IMRT. Methods and materials: A mail based audit involving film and alanine dosimeters was utilized. Measurements were made for each individual field in an IMRT plan isocentrically in a flat water-equivalent phantom at a depth of 5 cm. The films and alanine dosimeters were processed and analysed centrally; additional ion chamber measurements were made by each participating centre. Results: 57 of 62 centres participated, with a total of 78 plans submitted. For the film measurements, all 176 fields from the less complex IMRT plans (including prostate and breast plans) achieved over 95% pixels passing a gamma criterion of 3%/3 mm within the 20% isodose. For the more complex IMRT plans (mainly head and neck) 8/245 fields (3.3%) achieved less than 95% pixels passing a 4%/4 mm gamma criterion. Of the alanine measurements, 4/78 (5.1%) of the measurements differed by >5% from the dose predicted by the treatment planning system. Three of these were large deviations of -77.1%, -29.1% and 14.1% respectively. Excluding the three measurements outside 10%, the mean difference was 0.05% with a standard deviation of 1.5%. The out of tolerance results have been subjected to further investigations. Conclusions: A dosimetric audit has been successfully carried out of IMRT implementation by over 90% of UK radiotherapy departments. The audit shows that modelling and delivery of IMRT is accurate, suggesting that the implementation of IMRT has been carried out safely.

  18. Development of a dosimeter for high doses assessment based on Alanine/EPR

    International Nuclear Information System (INIS)

    Galante, O.L.; Rodrigues, O. Jr.; Campos, L.L.

    2000-01-01

    The increasing use of radiation sources of high activity for industrial and medical applications becomes important the research and the development of detectors and dosimetric methods for quality control of the applied doses. This work presents the current stage of the research at IPEN/CNEN-SP that has as objective the development of a standard dosimetric system for high doses assessment based on the alanine as radiation detector and electron paramagnetic resonance (EPR) as measurement technique. The developed system consists of the cylindrical container built in polyethylene of high density and the detector element based on DL-alanine commercially available. For the detector preparation different binding materials such as paraffin and acetate polyvinyl solution (pva) and also the use of a polyethylene tube of low density with 3.2 mm of external diameter, 2 mm of internal diameter and 30 mm of length were tested to provide the easier preparation method and the most sensitive detector. For the alanine + paraffin detector it was used 80% of alanine and 20% of paraffin, for the alanine + pva detector it was used 70% of alanine and 30% of pva solution, and pure alanine was encapsulated, compacted and sealed in the case of the polyethylene tube. The obtained results with respect to handling, packing and construction easiness showed that the polyethylene tube presents all characteristics to obtain of a good detector element. The validation of the dosimetric system was carried out with gamma radiation of the cobalt-60 with doses in the range between 0.2 Gy to 200 kGy. Type tests such as fading, lowest detection limit, reproducibility and energy dependence of the sign EPR were performed. All measurements were carried out at room temperature using a spectrometer of electron paramagnetic resonance (EPR) Bruker model MXE. Taking into account the results obtained: linearity of the EPR signal between 10 Gy and 50 kGy, reproducibility better than 3%, low fading associated with

  19. Dosimetric applications of the new ICRP lung model

    International Nuclear Information System (INIS)

    James, A.C.

    1994-06-01

    The International Commission on Radiological Protection (ICRP) has adopted a new dosimetric model of the human respiratory tract, to be issued as ICRP Publication 66. This chapter presents a summary of the main measures of the new model. The model is a general update of that in Publication 30, but is significantly broader in scope. It applies explicitly to workers and all members of the public: for inhalation of particles, gases and vapors; evaluation of dose per unit intake or exposure; and interpretation of bioassay data. The approach is fundamentally different from the Publication 30 model which calculates only the average dose to the lungs. The new model takes account of differences in radiosensitivity of respiratory tract tissues, and the wide range of doses they may receive, and calculates specific tissue doses. The model readily incorporates specific information related to the subject (age, physical activity, smoking or health status) or the exposure (aerosol size and chemical form). The application of the new model to calculate equivalent lung dose and effective dose per unit intake is illustrated for several α- and ∂-emitting radionuclides, and the new values obtained are compared with those given by the ICRP Publication 30 lung model

  20. SU-F-T-05: Dosimetric Evaluation and Validation of Newlydeveloped Well Chamber for Use in the Calibration of Brachytherapy Sources

    Energy Technology Data Exchange (ETDEWEB)

    Saminathan, S; Godson, H; Ponmalar, R; Manickam, R [Kidwai Memorial Institute of Oncology, Bangalore, Karnataka (India); Mazarello, J [Rosalina India private limited, Mumbai, Maharastra (India)

    2016-06-15

    Purpose: To evaluate the dosimetric characteristics of newly developed well type ionization chamber and to validate the results with the commercially available calibrated well chambers that are being used for the calibration of brachytherapy sources. Methods: The newly developed well type ionization chamber (BDS 1000) has been designed for the convenient use in brachytherapy which is open to atmospheric condition. The chamber has a volume of 240 cm3 and weight of 2.5 Kg. The calibration of the radioactive source with activities from 0.01 mCi to 20 Ci can be carried out using this chamber. The dosimetric parameters such as leakage current, stability, scattering effect, ion collection efficiency, reference air kerma rate and nominal response with energy were carried out with the BDS 1000 well type ion chamber. The evaluated dosimetric characteristics of BDS1000 well chamber were validated with two other commercially available well chambers (HDR 1000 plus and BTC/3007). Results: The measured leakage current observed was negligible for the newly developed BDS 1000 well type ion chamber. The ion collection efficiency was close to 1 and the response of the chamber was found to be very stable. The determined sweet spot was at 42 mm from bottom of the chamber insert. The reference air kerma rate was found to be 4.634 × 105 Gym2hr-1A-1 for the BDS 1000 well chamber. The overall dosimetric characteristics of BDS 1000 well chamber was in good agreement with the dosimetric properties of other two well chambers. Conclusion: The dosimetric study shows that the newly developed BDS 1000 well type ionization chamber is high sensitive and reliable chamber for reference air kerma strength calibration. The results obtained confirm that this chamber can be used for the calibration of HDR and LDR brachytherapy sources.

  1. SU-E-J-21: Setup Variability of Colorectal Cancer Patients Treated in the Prone Position and Dosimetric Comparison with the Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Kim, A; Foster, J; Chu, W; Karotki, A [Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: Many cancer centers treat colorectal patients in the prone position on a belly board to minimize dose to the small bowel. That may potentially Result in patient setup instability with corresponding impact on dose delivery accuracy for highly conformal techniques such as IMRT/VMAT. Two aims of this work are 1) to investigate setup accuracy of rectum patients treated in the prone position on a belly board using CBCT and 2) to evaluate dosimetric impact on bladder and small bowel of treating rectum patients in supine vs. prone position. Methods: For the setup accuracy study, 10 patients were selected. Weekly CBCTs were acquired and matched to bone. The CBCT-determined shifts were recorded. For the dosimetric study, 7 prone-setup patients and 7 supine-setup patients were randomly selected from our clinical database. Various clinically relevant dose volume histogram values were recorded for the small bowel and bladder. Results: The CBCT-determined rotational shifts had a wide variation. For the dataset acquired at the time of this writing, the ranges of rotational setup errors for pitch, roll, and yaw were [−3.6° 4.7°], [−4.3° 3.2°], and [−1.4° 1.4°]. For the dosimetric study: the small bowel V(45Gy) and mean dose for the prone position was 5.6±12.1% and 18.4±6.2Gy (ranges indicate standard deviations); for the supine position the corresponding dose values were 12.9±15.8% and 24.7±8.8Gy. For the bladder, the V(30Gy) and mean dose for prone position were 68.7±12.7% and 38.4±3.3Gy; for supine position these dose values were 77.1±13.7% and 40.7±3.1Gy. Conclusion: There is evidence of significant rotational instability in the prone position. The OAR dosimetry study indicates that there are some patients that may still benefit from the prone position, though many patients can be safely treated supine.

  2. SU-F-T-461: Dosimetric Evaluation of Indigenous Farmer Type Chamber FAR65- GB for Reference Dosimetry of FFF MV Photon Beam

    Energy Technology Data Exchange (ETDEWEB)

    Patwe, P; Mhatre, V; Dandekar, P [Sir HN RF Hospital, Mumbai, Maharashtra (India)

    2016-06-15

    Purpose: Indigenous Farmer type chamber FAR 65 GB is a reference class 0.6 cc ion chamber. It can be used for dosimetric evaluation of photon and high energy electron beams. We studied dosimetric characteristics of the chamber for 6MV and 10MV Flattening filter free FFF photon beams available on trueBEAM STx Linac. Methods: The study was carried out on trueBEAM STx Linac having 6 and 10 MV FFF photon beam with maximum dose rate 1400 and 2400 MU per min respectively. The dosimetric device to be evaluated is Rosalina Instruments FAR 65-GB Ion Chamber with active volume 0.65 cc, total active length 23.1cm, inner diameter of cylinder 6.2mm, wall thickness 0.4mm, inner electrode diameter 1mm. Inner and outer electrodes are made from Aluminium 2.7 gm per cc and graphite 1.82 gm per cc respectively. The ion chamber was placed along central axis of beam at 10cm depth and irradiated for 10cm × 10cm field size at SAD of 100 cm in plastic phantom. We studied Precision, Dose Linearity, Dose Rate dependence, directional dependence, Recombination effect. Recombination effect was determined using standard two-voltage method. Results: 1. Measurements were reproducible std deviation of 0.0105 and type A uncertainty 0.003265 under same set of reference conditions 2. Chamber exhibit dose linearity over a wider dose range. 3. Chamber shows dose rate independence for all available dose rate range. 4. Response of chamber with the angle of incidence of radiation is constant. 5. Recombination correction factors were 1.01848 and 1.02537 for dose rate 1400 and 2400 MU per min resp. Conclusion: Our study reveals that the chamber is prone to saturation effect at dose rate of 2400 MU per min. FAR 65-GB can be used for reference dosimetry of FFF MV photon beam with proper calculation of recombination effect.

  3. Thermoluminescent dosimetric properties of Descalvado sand

    International Nuclear Information System (INIS)

    Teixeira, M.I.; Caldas, L.V.E.

    2006-01-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ( 60 Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  4. Thermoluminescent dosimetric properties of Descalvado sand

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M.I.; Caldas, L.V.E

    2006-07-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ({sup 60} Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  5. MCID: A Software Tool to Provide Monte Carlo Driven Dosimetric Calculations Using Multimodality NM Images

    International Nuclear Information System (INIS)

    Vergara Gil, Alex; Torres Aroche, Leonel A; Coca Péreza, Marco A; Pacilio, Massimiliano; Botta, Francesca; Cremonesi, Marta

    2016-01-01

    Aim: In this work, a new software tool (named MCID) to calculate patient specific absorbed dose in molecular radiotherapy, based on Monte Carlo simulation, is presented. Materials & Methods: The inputs for MCID are two co-registered medical images containing anatomical (CT) and functional (PET or SPECT) information of the patient. The anatomical image is converted to a density map, and tissues segmentation is provided considering compositions and densities from ICRU 44 and ICRP; the functional image provides the cumulative activity map at voxel level (figure 1). MCID creates an input file for Monte Carlo (MC) codes such as MCNP5 and GATE, and converts the MC outputs into an absorbed dose image. Results: The developed tool allows estimating dose distributions for non-uniform activities distributions and non-homogeneous tissues. It includes tools for delineation of volumes of interest, and dosimetric data analysis. Procedures to decrease the calculation time are implemented in order to allow its use in clinical settings. Dose–volume histograms are computed and presented from the obtained dosimetric maps as well as dose statistics such as mean, minimum and maximum dose values; the results can be saved in common medical image formats (Interfile, DICOM, Analyze, MetaImage). The MCID was validated by comparing estimated dose values versus reference data, such as gold standards phantoms (OLINDA´s spheres) and other MC simulations of non-homogeneous phantoms. A good agreement was obtained in spheres ranged 1g to 1kg of mass and in non-homogeneous phantoms. Clinical studies were also examined. Dosimetric evaluations in patients undergoing 153Sm-EDTMP therapy for osseous metastases showed non-significant differences with calculations performed by traditional methods. The possibility of creating input files to perform the simulations using the Gate Code has increased the MCID applications and improved its functionality, Different clinical situations including PET and SPECT

  6. Foetal dosimetry--is the ICRP dosimetric system for humans now complete?

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Steve [Westlakes Research Institute, Cumbria (United Kingdom)

    2002-03-01

    Internal dosimetry is possibly the most complex area of science associated with radiological protection, and has a long history. Primary control of internal exposure now relied on control of annual intakes rather than limitation of organ burdens. Although it took nearly a decade for regulations and hence the practice of occupational radiation protection to fully adopt the new recommendations, the new dosimetric concepts were quite rapidly adopted in the assessment of public exposure because the new methods provided a more natural means of assessing the significance of exposure to a combination of external and internal exposure involving a number of different radionuclides. As a result, following the ICRP's initial publication of dosimetric models for occupational exposure, adaptations became available to cover environmental exposure, including the exposure of infants and children. Increasingly sophisticated biokinetic and dosimetric models have now been developed which, together with the welcome availability of dose per unit intake factors in CD-ROM form make it easy for the radiation protection practitioner to assess committed effective doses, and committed equivalent doses to individual organs, to occupationally exposed adults and environmentally exposed infants, children and adults. The inability to readily assess doses to the developing foetus has, however, long been perceived as a significant gap in knowledge with implications for the study of childhood leukaemia in the vicinity of nuclear installations and possibly also the control of occupational exposure for women of child-bearing age. The first systematic assessment of doses to the foetus was in connection with the study of childhood leukaemia in the vicinity of Sellafield in the UK, for which preliminary models were developed. Since that time a few publications giving guidance on the calculation of foetal doses have emerged and more sophisticated assessments of foetal dose have been reported

  7. Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams.

    Science.gov (United States)

    Kadoya, Noriyuki; Shimomura, Kouhei; Kitou, Satoshi; Shiota, Yasuo; Fujita, Yukio; Dobashi, Suguru; Takeda, Ken; Jingu, Keiichi; Matsushita, Haruo; Namito, Yoshihito; Ban, Syuichi; Koyama, Syuji; Tabushi, Katsuyoshi

    2012-10-01

    A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosimetric properties of the RGD, including energy dependence of the dose response, reproducibly, variation in data obtained by the RGD for each energy, and angular dependence in low-energy photons, are discussed. An RGD (GD-301, Asahi Techno Glass Corporation, Shizuoka, Japan) was irradiated with monochromatic low-energy photon beams generated by synchrotron radiation at Photon Factory, High Energy Accelerator Research Organization (KEK). The size of GD-301 was 1.5 mm in diameter and 8.5 mm in length and the active dose readout volume being 1 mm diameter and 0.6 mm depth located 0.7 mm from the end of the detector. The energy dependence of the dose response and reproducibility and variation were investigated for RGDs irradiated with a plastic holder and those irradiated without the plastic holder. Response of the RGD was obtained by not only conventional single field irradiation but also bilateral irradiation. Angular dependence of the RGD was measured in the range of 0°-90° for 13, 17, 40, and 80 keV photon beams by conventional single field irradiation. The dose responses had a peak at around 40 keV. For the energy range of less than 25 keV, all dose response curves steeply decreased in comparison with the ratio of mass energy absorption coefficient of the RGD to that of air. As for the reproducibility and variation in data obtained by the RGD, the coefficient of variance increased with decrease in photon energy. Furthermore, the variation for bilateral irradiation was less than that for single field irradiation. Regarding angular dependence of the RGD, for energies of 13 and 17 keV, the response decreased with increase in the irradiation angle, and the

  8. Dosimetric impact of interplay effect in lung IMRT and VMAT treatment using in-house dynamic thorax phantom

    International Nuclear Information System (INIS)

    Mukhlisin; Pawiro, S A

    2016-01-01

    Tumor motion due to patient's respiratory is a significant problem in radiotherapy treatment of lung cancer. The purpose of this project is to study the interplay effect through dosimetry verification between the calculated and delivered dose, as well as the dosimetric impact of leaf interplay with breathing-induced tumor motion in IMRT and VMAT treatment. In this study, a dynamic thorax phantom was designed and constructed for dosimetry measurement. The phantom had a linear sinusoidal tumor motion toward superior-inferior direction with variation of amplitudes and periods. TLD-100 LiF:Mg,Ti and Gafchromic EBT2 film were used to measure dose in the midpoint target and the spinal cord. The IMRT and VMAT treatment had prescription dose of 200 cGy per fraction. The dosimetric impact due to interplay effect during IMRT and VMAT treatment were resulted in the range of 0.5% to -6.6% and 0.9% to -5.3% of target dose reduction, respectively. Meanwhile, mean dose deviation of spinal cord in IMRT and VMAT treatment were around 1.0% to -6.9% and 0.9% to -6.3%, respectively. The results showed that if respiratory management technique were not implemented, the presence of lung tumor motion during dose delivery in IMRT and VMAT treatment causes dose discrepancies inside tumor volume. (paper)

  9. Tenon hospital 3-D dosimetric methodology for radiosurgery of complex AVMs

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Schlienger, M.; Plazas, M.C.; Laugier, A.

    1990-01-01

    This paper presents the methodology of the irradiation treatment planning for the calculation of the 3-D dose distribution developed at the Tenon Hospital since four years. This dosimetric method is independent of the Linac irradiation technique, thus is can be used with any other type of radiosurgery technique. (author)

  10. Radiodine treatment of hyperthyroidism with a simplified dosimetric approach. Clinical results

    International Nuclear Information System (INIS)

    Giovanella, L.; De Palma, D.; Ceriani, L.; Garancini, S.; Vanoli, P.; Tordiglione, M.; Tarolo, G. L.

    2000-01-01

    12 of 146% (8%) patients hyperthyroid. Two patients were immediately submitted to a new radioiodine administration. One year posttreatment 142 of 146 (97%) patients were euthyroid while only 4 of 146 (3%) patients showed TSH levels above the normal range. Only 2 of them required thyroxine treatment. The simplified dosimetric method illustrated in this paper is very effective in clinical practice because it permits to avoid resorting to sophisticated but also imprecise quantitative methods. Hypothyroidism should not be considered as a major collateral effect of radioiodine treatment, particularly in Graves' disease. In fact, the pathogenesis of the disease requires an ablative treatment with both surgery and radioiodine treatment and the control of hyperthyroidism and the prevention of relapse are the major clinical targets. Vice versa, hypothyroidism was very uncommon in uni- and multinodular toxic goiter when the dosimetric approach was applied [it

  11. Development of an algorithm simulator of the planar radioactive source for dosimetric evaluations in accidents with radiopharmaceuticals used in nuclear medicine

    International Nuclear Information System (INIS)

    Claudino, Gutemberg L. Sales; Vieira, Jose Wilson; Leal Neto, Viriato; Lima, Fernando R. Andrade

    2013-01-01

    Objective of this work is to develop an algorithm simulator for dosimetric evaluation of accidents that may happen in Nuclear Medicine using PDF NT (Probability Density Functions). A software was developed using C# and WPF technology, in the integrated environment of Microsoft Visual Studio to organize and present the dosimetric results

  12. Dosimetric and volumetric criteria for selecting a source activity and a source type (125I or 103Pd) in the presence of irregular seed placement in permanent prostate implants

    International Nuclear Information System (INIS)

    Wuu, C.-S.; Ennis, Ronald D.; Schiff, Peter B.; Lee, Eva K.; Zaider, Marco

    2000-01-01

    Purpose: The dosimetric merit of a permanent prostate implant relies on two factors: the quality of the plan itself, and the fidelity of its implementation. The former factor depends on source type and on source strength, while the latter is a combination of skill and experience. The purpose of this study is to offer criteria by which to select a source type ( 125 I or 103 Pd) and activity. Methods and Materials: Given a prescription dose and potential seed positions along needles, treatment plans were designed for a number of seed types and activities, specifically for 125 I with activities ranging from 0.3 to 0.7 mCi, and for 103 Pd with activities in the range of 0.8 to 1.6 mCi. To avoid human planner bias, an automated computerized planning system based on integer programming was used to obtain optimal seed configurations for each seed type and activity. To simulate the effect of seed-placement inaccuracies, random seed-displacement 'errors' were generated for all plans. The displacement errors were assumed to be uniformly distributed within a cube with side equal to 2no. sigmano. The resulting treatment plans were assessed using two volumetric and two dosimetric indices. Results: For 125 I implants a coverage index (CI) of 98.5% or higher can be achieved for all activities (CI is the fraction of the target volume receiving the prescribed or larger dose). The external volume index (EI) (i.e., the amount of healthy tissue, as percentage of the target volume, receiving the prescribed or larger dose) increases from 13.9% to 20% as the activity increases from 0.3 to 0.7 mCi. For implants using 103 Pd, the external volume index increases from 10.2% to 13.9% whenever CI exceeds 98.5%. Volumetric and dosimetric indices (coverage index, external volume index, D90, and D80) are all sensitive to seed displacement, although the activity dependence of these indices is more pronounced for 125 I than for 103 Pd implants. Conclusions: For both isotopes, the lower activities

  13. Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

    Energy Technology Data Exchange (ETDEWEB)

    Mutaf, Yildirim D.; Yi, Byong Yong; Prado, Karl; D' Souza, Warren D.; Regine, William F.; Feigenberg, Steven J. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States); Zhang Jin [Xcision Medical Systems, Columbia, Maryland 21045 (United States); Yu, Cedric X. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 and Xcision Medical Systems, Columbia, Maryland 21045 (United States)

    2013-04-15

    Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver

  14. Assessment of Alaska reindeer populations and range conditions

    Directory of Open Access Journals (Sweden)

    J. D. Swanson

    1992-10-01

    Full Text Available Populations of reindeer (Rangifer tarandus have fluctated greatly since their introduction to Alaska in 1891. In the 1930s, reported numbers exceeded 600 000. Presently, 38 000 reindeer graze 6.2 million ha of rangeland and woodland in Western Alaska (from 66°54'N to 52°07'N latitude. Condition of winter range producing fruticose lichens (Cladina rangiferina, Cladina arbuscula, Cladina stellaris, Cetraria cucullata, Cetraria islandica is of major concern. Monitoring programs have been established for vegetation, fire, reindeer and wildlife. Reindeer have overgrazed lichen resources on some Bering Sea Islands. Wildfires have had the greatest impact on lichen range depletion on the mainland. Overgrazing has been a problem in localized areas. Moose (Alces alces and muskox (Ovibos moschatus rarely contribute to major lichen depletion. 60-80% of the mainland and 5-30% of most island winter lichen ranges are presently estimated to be in good to excellent ecological condition. Procedures for assessing condition of the lichen ranges are being further refined.

  15. Dosimetric behavior of thermoluminescent dosimeters at low doses in diagnostic radiology; Comportamiento dosimetrico de dosimetros termoluminiscentes a bajas dosis en radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Del Sol F, S.; Garcia S, R.; Guzman M, J.; Sanchez G, D.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Ramirez R, G. [Hospital Juarez de Mexico, Av. IPN 5160, Col. Magdalena de las Salinas, 07760 Mexico D. F. (Mexico); Gaona, E., E-mail: susi2489@hotmail.com [Universidad Autonoma Metropolitana, Unidad Xochimilco, Calz. del Hueso 1100, Col. Villa Quietud, 04960 Mexico D. F. (Mexico)

    2015-10-15

    Thermoluminescent (Tl) characteristics of TLD-100, LiF:Mg,Cu,P, and CaSO{sub 4}: Dy the under homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescent dosimetry is presented. The irradiations were performed utilizing an X-ray beam generated by a Radiology Mexican Company: MRH-II E GMX 325-AF SBV-1 model, with Rotating Anode X-Ray Tube installed in the Hospital Juarez Norte de Mexico in Mexico City. Different thermoluminescent characteristics of dosimetric material were studied, such as, batch homogeneity, Tl glow curve, Tl response as a function of X-ray dose, reproducibility and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and positioned in a generic Phantom was used. Dose verification and comparison with the measurements made with that obtained by TLD-100 were analyzed. Preliminary results indicate the dosimetric peak appears at 243, 236 and 277 ± 5 degrees C respectively, these peaks are in agreement with that reported in the literature. Tl glow curve as a function of X-ray dose showed a linearity in the range from 1.76 mGy up to 14.70 mGy for all materials. Fading for a period of one month at room temperature showed low fading LiF:Mg,Cu,P, medium and high for TLD-100 and CaSO{sub 4}: Dy. The results suggest that the three materials are suitable for measurements at low doses in radiodiagnostic, however, for its dosimetric characteristics are most effective for individual applications: personal dosimetry and monitors limb (LiF:Mg,Cu,P), clinical dosimetry and environmental (TLD-100 and CaSO{sub 4}: Dy). (Author)

  16. Development and design of an antropomorphic model for electron dosimetric purposes

    International Nuclear Information System (INIS)

    Geske, G.; Geske, J.

    1977-01-01

    After discussing some problems related to the planning of therapeutic irradiation with fast electron the benifit of phantoms for electron dosimetric purposes is pointed out. The selection of tissue-equivalent materials for constructing a phantom is dicussed in detail. Finally, a model representing the upper part of a female body is described. (author)

  17. Estimation of electromagnetic dosimetric values from non-ionizing radiofrequency fields in an indoor commercial airplane environment.

    Science.gov (United States)

    Aguirre, Erik; Arpón, Javier; Azpilicueta, Leire; López, Peio; de Miguel, Silvia; Ramos, Victoria; Falcone, Francisco

    2014-12-01

    In this article, the impact of topology as well as morphology of a complex indoor environment such as a commercial aircraft in the estimation of dosimetric assessment is presented. By means of an in-house developed deterministic 3D ray-launching code, estimation of electric field amplitude as a function of position for the complete volume of a commercial passenger airplane is obtained. Estimation of electromagnetic field exposure in this environment is challenging, due to the complexity and size of the scenario, as well as to the large metallic content, giving rise to strong multipath components. By performing the calculation with a deterministic technique, the complete scenario can be considered with an optimized balance between accuracy and computational cost. The proposed method can aid in the assessment of electromagnetic dosimetry in the future deployment of embarked wireless systems in commercial aircraft.

  18. A dosimetric intercomparison of brachytherapy facilities in Ireland, Scotland and the North of England

    International Nuclear Information System (INIS)

    Heeney, Conor; McClean, Brendan; Kelly, Colin

    2005-01-01

    Background and purpose: A dosimetric intercomparison of brachytherapy remote afterloading units in Ireland, Scotland and the North of England has been carried out involving 9 radiotherapy centres, and sampling 5 HDR and 6 LDR units. Materials and methods: Absolute calibrations have been performed in air on both HDR and LDR sources. The results are expressed in terms of a ratio of local to calibrated value. Frequency distributions were obtained for the multi-source LDR units by individually measuring each source. Using these distributions the effect of non-uniform source strength on the dose rate at Manchester point A was assessed for a typical clinical brachytherapy insertion for carcinoma of the cervix. Both frequency and dose rate distribution curves were modeled using normal statistics and characterised in terms of the mean (μ) and standard deviation (σ). Results: Evaluation of the HDR units indicated a mean ratio of 1.008 (±0.01) while for LDR the mean ratio was 0.997 (±0.02). The LDR frequency distributions demonstrated a variation of σ values extending from 1.4 to 3.0% of μ. It was shown that this non-uniformity in source strength introduced an uncertainty in the treatment planning process of between 0.8 and 1.8% when compared to the assumption of uniform source strength. Conclusions: The results of this intercomparison indicate dosimetric consistency between centres for both LDR and HDR units. The distribution of LDR source strengths were within expected limits and the resultant dose rate distributions were considered clinically acceptable

  19. Dosimetric complication probability and acoustic analysis of vocal cord region in oropharyngeal carcinoma treated with voice-sparing intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Jain, S.; Gupta, T.; Agarwal, J.P.; Baccher, G.; Shrivastava, S.K.; Reenadevi; Master, J.

    2008-01-01

    Radiation to larynx has long been associated with speech and voice dysfunction. The objective is to study dosimetric parameters and complication probability of vocal cord region (VCR) and the effect of voice-sparing (VS) in the patients treated with intensity modulated radiotherapy (IMRT). The secondary objective is to describe the post-radiation acoustic voice characteristics and correlate them with the dosimetric parameters. (author)

  20. Dosimetric study of optimal beam number and arrangement for treatment of nasopharyngeal carcinoma with intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Budrukkar, Ashwini; Corry, June; Peters, Lester J.; Hope, Geoff; Cramb, Jim

    2004-01-01

    The purpose of this dosimetric study was to evaluate the effect of beam number and arrangement on the dose distribution with intensity-modulated radiation therapy in patients with nasopharyngeal cancer. Computed tomography data sets of seven patients who were treated for nasopharyngeal carcinoma at the Peter MacCallum Cancer Centre were used for the present dosimetric study. The dose planned was 70 Gy in 7 weeks for the gross nasopharyngeal and nodal disease and the biological equivalents of 60 Gy in 6 weeks for the high-risk and 50 Gy in 5 weeks for the low-risk nodal disease. A plan using seven fields was compared to that using nine fields in all patients. Plans were assessed on the dose to the planning target volume (PTV) and the degree of parotid sparing achieved by evaluating both dose-volume histograms (DVH) and axial slices. Seven fields (three anterior and four posterior) provide good PTV coverage and satisfactory parotid sparing in patients with localized nasopharyngeal lesions. Nine fields appear to be better for tumours with significant posterolateral parapharyngeal extension. Parotid sparing is consistently better with nine fields. Both DVH and axial slices need to be evaluated before accepting any plan Copyright (2004) Blackwell Publishing Asia Pty Ltd

  1. Quantitative analysis of patient-specific dosimetric IMRT verification

    International Nuclear Information System (INIS)

    Budgell, G J; Perrin, B A; Mott, J H L; Fairfoul, J; Mackay, R I

    2005-01-01

    Patient-specific dosimetric verification methods for IMRT treatments are variable, time-consuming and frequently qualitative, preventing evidence-based reduction in the amount of verification performed. This paper addresses some of these issues by applying a quantitative analysis parameter to the dosimetric verification procedure. Film measurements in different planes were acquired for a series of ten IMRT prostate patients, analysed using the quantitative parameter, and compared to determine the most suitable verification plane. Film and ion chamber verification results for 61 patients were analysed to determine long-term accuracy, reproducibility and stability of the planning and delivery system. The reproducibility of the measurement and analysis system was also studied. The results show that verification results are strongly dependent on the plane chosen, with the coronal plane particularly insensitive to delivery error. Unexpectedly, no correlation could be found between the levels of error in different verification planes. Longer term verification results showed consistent patterns which suggest that the amount of patient-specific verification can be safely reduced, provided proper caution is exercised: an evidence-based model for such reduction is proposed. It is concluded that dose/distance to agreement (e.g., 3%/3 mm) should be used as a criterion of acceptability. Quantitative parameters calculated for a given criterion of acceptability should be adopted in conjunction with displays that show where discrepancies occur. Planning and delivery systems which cannot meet the required standards of accuracy, reproducibility and stability to reduce verification will not be accepted by the radiotherapy community

  2. Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience

    International Nuclear Information System (INIS)

    Zijtveld, Mathilda van; Dirkx, Maarten L.P.; Boer, Hans C.J. de; Heijmen, Ben J.M.

    2006-01-01

    Background and purpose: In our clinic a QA program for IMRT verification, fully based on dosimetric measurements with electronic portal imaging devices (EPID), has been running for over 3 years. The program includes a pre-treatment dosimetric check of all IMRT fields. During a complete treatment simulation at the linac, a portal dose image (PDI) is acquired with the EPID for each patient field and compared with a predicted PDI. In this paper, the results of this pre-treatment procedure are analysed, and intercepted errors are reported. An automated image analysis procedure is proposed to limit the number of fields that need human intervention in PDI comparison. Materials and methods: Most of our analyses are performed using the γ index with 3% local dose difference and 3 mm distance to agreement as reference values. Scalar parameters are derived from the γ values to summarize the agreement between measured and predicted 2D PDIs. Areas with all pixels having γ values larger than one are evaluated, making decisions based on clinically relevant criteria more straightforward. Results: In 270 patients, the pre-treatment checks revealed four clinically relevant errors. Calculation of statistics for a group of 75 patients showed that the patient-averaged mean γ value inside the field was 0.43 ± 0.13 (1 SD) and only 6.1 ± 6.8% of pixels had a γ value larger than one. With the proposed automated image analysis scheme, visual inspection of images can be avoided in 2/3 of the cases. Conclusion: EPIDs may be used for high accuracy and high resolution routine verification of IMRT fields to intercept clinically relevant dosimetric errors prior to the start of treatment. For the majority of fields, PDI comparison can fully rely on an automated procedure, avoiding excessive workload

  3. Dosimetric characteristics of a TLD dosemeter with extremities

    International Nuclear Information System (INIS)

    Molina P, D.; Diaz B, E.; Lien V, R.

    1999-01-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm 3 covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  4. Dosimetric evaluation of Radiotherapy units wit 60Co

    International Nuclear Information System (INIS)

    Leon, B. Salinas de; Tovar M, V.; Becerril V, A.

    2000-01-01

    The SSDL network of the IAEA performs, every year, quality audit tests for radiotherapy services ( 60 Co units and linear accelerators), and for national SSDL as well. Because of the SSDL-Mexico results in these tests and due to our enthusiasm and confidence in our work, a parallel test has been done , which is described in this talk as well as the results. Nowadays, a second parallel test goes up, which could confirm our optimism and open the possibility to our country to start a national dosimetric audit of 60 Co radiotherapy units. (Author)

  5. SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

    Energy Technology Data Exchange (ETDEWEB)

    Mamalui, M; Su, Z; Flampouri, S; Li, Z [University of Florida Proton Therapy Institute, Jacksonville, FL (United States)

    2016-06-15

    Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

  6. SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

    International Nuclear Information System (INIS)

    Mamalui, M; Su, Z; Flampouri, S; Li, Z

    2016-01-01

    Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

  7. Evaluation of dosimetric characteristics of graphene oxide/PVC nanocomposite for gamma radiation applications

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shahzad; Malekie, Shahryar; Ziaie, Farhood [Nuclear Science and Technology Research Institute (NSTRI), Karaj (Iran, Islamic Republic of). Radiation Application Research School; Rahighi, Reza; Tayyebi, Ahmad [Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Physics

    2017-04-01

    Graphene oxide-polyvinyl chloride composite was prepared using tetrahydrofuran solvent-assisted dispersion of characterized nano flakes of graphene oxide in polymer matrix. Electrical percolation threshold of GO/PVC nanocomposite was determined via a finite element simulation method with a 2D model and compared with experimental results. A conductive cell with two silver coated walls was designed and fabricated for exploring dosimetric properties of the composite. Some characteristics of the new nanocomposite such as linearity of dose response, repeatability, sensitivity and angular dependence are investigated. According to 2D proposed method, obtained data associated to electrical conductivity of the GO/polymer composite for PVC matrix plotted in different GO weight percentages and had good compatibility (validity) with experimental data. The dose response is linear in the 17-51 mGy dose range and it can be introduced for gamma radiation dosimetry in diagnostic activities.

  8. REIDAC. A software package for retrospective dose assessment in internal contamination with radionuclides

    International Nuclear Information System (INIS)

    Kurihara, Osamu; Kanai, Katsuta; Takada, Chie; Takasaki, Koji; Ito, Kimio; Momose, Takumaro; Hato, Shinji; Ikeda, Hiroshi; Oeda, Mikihiro; Kurosawa, Naohiro; Fukutsu, Kumiko; Yamada, Yuji; Akashi, Makoto

    2007-01-01

    For cases of internal contamination with radionuclides, it is necessary to perform an internal dose assessment to facilitate radiation protection. For this purpose, the ICRP has supplied the dose coefficients and the retention and excretion rates for various radionuclides. However, these dosimetric quantities are calculated under typical conditions and are not necessarily detailed enough for dose assessment situations in which specific information on the incident or/and individual biokinetic characteristics could or should be taken into account retrospectively. This paper describes a newly developed PC-based software package called Retrospective Internal Dose Assessment Code (REIDAC) that meets the needs of retrospective dose assessment. REIDAC is made up of a series of calculation programs and a package of software. The former calculates the dosimetric quantities for any radionuclide being assessed and the latter provides a user with the graphical user interface (GUI) for executing the programs, editing parameter values and displaying results. The accuracy of REIDAC was verified by comparisons with dosimetric quantities given in the ICRP publications. This paper presents the basic structure of REIDAC and its calculation methods. Sensitivity analysis of the aerosol size for 239 Pu compounds and provisional calculations for wound contamination with 241 Am were performed as examples of the practical application of REIDAC. (author)

  9. Dosimetric Comparison in Breast Radiotherapy of 4 MV and 6 MV on Physical Chest Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Donato da Silva, Sabrina; Passos Ribeiro Campos, Tarcisio [Nuclear Engineering Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Batista Nogueira, Luciana [Anatomy and Imaging Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Lima Souza Castro, Andre [Nuclear Engineering Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Institute of Radiation San Francisco, Belo Horizonte (Brazil); Alves de oliveira, Marcio; Galvao Dias, Humberto [Cancer Hospital in Uberlandia, Uberlandia (Brazil)

    2015-07-01

    According to the World Health Organization (2014) breast cancer is the main cause of death by cancer in women worldwide. The biggest challenge of radiotherapy in the treatment of cancer is to deposit the entire prescribed dose homogeneously in the breast, sparing the surrounding tissue. In this context, this paper aimed at evaluating and comparing internal dose distribution in the mammary gland based on experimental procedures submitted to two distinct energy spectra produced in breast cancer radiotherapy. The methodology consisted of reproducing opposite parallel fields used in the treatment of breast tumors in a chest phantom. This simulator with synthetic breast, composed of equivalent tissue material (TE), was previously developed by the NRI Research Group (UFMG). The computer tomography (CT) scan of the simulator was obtained antecedently. The radiotherapy planning systems (TPS) in the chest phantom were performed in the ECLIPSE system from Varian Medical Systems and CAT 3D system from MEVIS. The irradiations were reproduced in the Varian linear accelerator, model SL- 20 Precise, 6 MV energy and Varian linear accelerator, 4 MV Clinac 6x SN11 model. Calibrations of the absorbed dose versus optical density from radiochromic films were generated in order to obtain experimental dosimetric distribution at the films positioned within the glandular and skin equivalent tissues of the chest phantom. The spatial dose distribution showed equivalence with the TPS on measurement data performed in the 6 MV spectrum. The average dose found in radiochromic films placed on the skin ranged from 49 to 79%, and from 39 to 49% in the mammary areola, for the prescribed dose. Dosimetric comparisons between the spectra of 4 and 6 MV, keeping the constant geometry of the fields applied in the same phantom, will be presented showing their equivalence in breast radiotherapy, as well as the variations will be discussed. To sum up, the dose distribution has reached the value expected in

  10. Dose-to-medium vs. dose-to-water: Dosimetric evaluation of dose reporting modes in Acuros XB for prostate, lung and breast cancer

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-12-01

    Full Text Available Purpose: Acuros XB (AXB dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS. The AXB can report the absorbed dose in two modes: dose-to-water (Dw and dose-to-medium (Dm. The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four groups of patients (prostate cancer, stereotactic body radiation therapy (SBRT lung cancer, left breast cancer, and right breast cancer were selected for this study, and each group consisted of 5 cases. The treatment plans of all cases were generated in the Eclipse TPS. For each case, treatment plans were computed using AXB_Dw and AXB_Dm for identical beam arrangements. Dosimetric evaluation was done by comparing various dosimetric parameters in the AXB_Dw plans with that of AXB_Dm plans for the corresponding patient case. Results: For the prostate cancer, the mean planning target volume (PTV dose in the AXB_Dw plans was higher by up to 1.0%, but the mean PTV dose was within ±0.3% for the SBRT lung cancer. The analysis of organs at risk (OAR results in the prostate cancer showed that AXB_Dw plans consistently produced higher values for the bladder and femoral heads but not for the rectum. In the case of SBRT lung cancer, a clear trend was seen for the heart mean dose and spinal cord maximum dose, with AXB_Dw plans producing higher values than the AXB_Dm plans. However, the difference in the lung doses between the AXB_Dm and AXB_Dw plans did not always produce a clear trend, with difference ranged from -1.4% to 2.9%. For both the left and right breast cancer, the AXB_Dm plans produced higher maximum dose to the PTV for all cases. The evaluation of the maximum dose to the skin showed higher values in the AXB_Dm plans for all 5 left breast cancer cases, whereas only 2 cases had higher maximum dose to the skin in the AXB_Dm plans for the right breast cancer

  11. Dosimetric studies in diagnostic radiology

    International Nuclear Information System (INIS)

    Mohamadain, K. E. M.

    2004-04-01

    A dosimetric study in pediatric radiology and adult patients was currently being carried out at the pediatrics units of two large hospitals in Rio de Janeiro city: IPPMG (Instituto de Pediatric e Puericultura Martagao Gesteira, University hospital of federal University of Rio de Janeiro), IFF (Instituto Fernandes Figueira, FIOCRUZ) and Hospital Geral de Bonsucesso, a large public hospital in Rio de Janeiro city (HGB) Brazil. The dosimetric study was also performed at three pediatrics units in Sudan, namely, Ahmed Gasim, Khartoum and Omdurman hospitals. For chest x-ray examination the entrance skin dose(ESD) for AP, PA and LAT projections of pediatric patients, and the scattered dose at the thyroid, ovary and gonads have been obtained with thermoluminescent dosimeters (TLD) and with use of a software package Dosecal in thr Brazilian hospitals, and with the software dosecal in the Sudanese hospitals.The aim of this work was to estimate the entrance skin dose (ESD), the effective dose (ED) and the body organ dose (BOD) for chest x-ray exposure in pediatric patients, and different exams for adults patients, and to compare the results obtained in the tow Countries Sudan and Brazil with the reference dose level. For ESD evaluation of the chest x-ray, three different TL dosimeters have been used, namely LiF: Mg, Ti (TLD 100) CaSo 4 : Dy and LiF:Mg, Cu,P (TLD 100 H). The age intervals considered were: 0-1 years, 1-5 years, 5-10 years and 10-15 years. The results obtained with all dosimeters were in good agreement with, those obtained by the dosecal software, especially for AP and PA projection. However, some discrepancies were found for the LAT projection. The results within Brazil were some what consistent while in Sudan, large difference were observed, it was also noted that the doses in Brazil hospitals were less than the reference dose levels while in Sudanese hospitals the doses were higher than the reference dose levels. For adult patients only the software dosecal

  12. Dosimetric properties of MOS transistors

    International Nuclear Information System (INIS)

    Frank, H.; Petr, I.

    1977-01-01

    The structure of MOS transistors is described and their characteristics given. The experiments performed and data in the literature show the following dosimetric properties of MOS transistors: while for low gamma doses the transistor response to exposure is linear, it shows saturation for higher doses (exceeding 10 3 Gy in tissue). The response is independent of the energy of radiation and of the dose rate (within 10 -2 to 10 5 Gy/s). The spontaneous reduction with time of the spatial charge captured by the oxide layer (fading) is small and acceptable from the point of view of dosimetry. Curves are given of isochronous annealing of the transistors following irradiation with 137 Cs and 18 MeV electrons for different voltages during irradiation. The curves show that in MOS transistors irradiated with high-energy electrons the effect of annealing is less than in transistors irradiated with 137 Cs. In view of the requirement of using higher temperatures (approx. 400 degC) for the complete ''erasing'' of the captured charge, unsealed systems must be used for dosimetric purposes. The effect was also studied of neutron radiation, proton radiation and electron radiation on the MOS transistor structure. For MOS transistor irradiation with 14 MeV neutrons from a neutron generator the response was 4% of that for gamma radiation at the same dose equivalent. The effect of proton radiation was studied as related to the changes in MOS transistor structure during space flights. The response curve shapes are similar to those of gamma radiation curves. The effect of electron radiation on the MOS structure was studied by many authors. The experiments show that for each thickness of the SiO 2 layer an electron energy exists at which the size of the charge captured in SiO 2 is the greatest. All data show that MOS transistors are promising for radiation dosimetry. The main advantage of MOS transistors as gamma dosemeters is the ease and speed of evaluation, low sensitivity to neutron

  13. Dosimetric characterization of a 2-D array of 223 solid state detectors for daily morning checks in Tomo Therapy equipment

    International Nuclear Information System (INIS)

    Reyes S, U.; Sosa A, M.; Vega C, H. R.

    2015-10-01

    Tomo Therapy is a new technique for the cancer treatment; however, the equipment must meet nearly all mechanical and dosimetric characteristics of a conventional linear accelerator for medical use. Daily quality controls are vital to the good operation of the equipment and thus guarantee excellent quality in the daily delivery of treatments. This paper presents the procedure of the dosimetric characterization of a two-dimensional array of 223 solid state detectors, called TomoDose of the Sun Nuclear Company. Dosimetric important criteria are established to perform these checks quickly and accurately. Dosimetric tests proposed are: repeatability, linearity, dependence of Sad and SSD. Some results are compared with readings of the ionization chamber Exradim A1SL. Finally the results of 30 consecutive days are presented to establish criteria for evidence of dose, field size, symmetry and flattening of the radiation beam on Tomo Therapy equipment. Expected values for daily verification are: Dose constancy of 194.89 c Gy, σ= 1.31 c Gy, symmetry in the X axis of -0.19 %, σ=0.08 %, symmetry in the Y axis of 1.66 %, σ= 0.05 %, flattened in the X axis of 25.71 %, σ= 0.05 % and flattened in the Y axis of 6.41 %, σ= 10.23 %. Field sizes obtained were 40.45 cm in the X axis and 5.10 on the Y axis, with standard deviations of 0.02 cm and 0.01 cm, respectively. TomoDose dosimetric values, compared to the values obtained with ionization chamber, presented differences smaller than 2%. (Author)

  14. Introduction dosimetric data of cobalt-60 unit in planning new Win-PTL- 3D

    International Nuclear Information System (INIS)

    Gonzalez Perez, Yelina; Rodriguez Zayas, Michael; Perez Guevara, Adrian; Sanchez Zamora, Luis; Reyes Gonzalez, Tommy; Sola Rodriguez, Yeline; Caballero, Roberto; Cruz Marcane, Viviana

    2009-01-01

    3D planning is based on the individual and image reconstruction formation of fields, allowing better absorption of dose volume White minimizing damage to surrounding healthy tissue. During the clinical implementation of the Win-PLT software includes validation from the implementation of dosimetric acceptance tests through a series of precise experimental measurements, reflecting different clinical situations (test cases). For the commissioning characterized the photon beam Cobalt Unit 60, taking measurements with a set consisting of a phantom dosimetric automatic ionization chambers and electrometer Tandem. The measured data are used to power the TPS through WINCOM auxiliary program that lets you adjust a number of parameters to model the photon beam. This adjustment is made by comparing the PDD curves and profiles of experimental data with modeled data. The test cases performed are in compliance with the requirements proposed in the geometric of the AAPM TG55. The modeling of beam dosimetry data was successful, since the discrepancies were within the criteria TRS-430. The cases involved events where points near the edge of the field and in the presence of blocking a discrepancy outside the tolerance, suggesting not to use these items for purposes of limitation. Win TPS-PLT is suitable for clinical use with the photon beam Cobalt Unit 60, backed by the reliability that dropped on the results of beam modeling and verification of dosimetric calculations. (Author)

  15. Dosimetric Impact of Primary Planning Parameters in Dynamic Conformal Arc Technique for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Yeon; Suh, Tae Suk [Dept. of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Si Yong [Dept. of Radiation Oncology, Mayo Clinic, Jacksonvile (United States); Lee, Jeong Woo [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Choi, Kyoung Sik [Dept. of Radiation Oncology, Anyang SAM Hospital, Anyang (Korea, Republic of)

    2011-04-15

    As one of the stereotactic body radiation therapy (SBRT) techniques, dynamic conformal arc therapy (DCAT) is commonly adopted to efficiently deliver conformal doses. However, as the DCAT uses numerous beams at individual control points, the dosimetric errors generated from each beam can be accumulated and manifested. In SBRT, therefore, due to the high fractional dose within a few fractions to moving target, the determination of the applied plan parameters can be critical and the evaluation of dosimetric impact of planning parameters would play an important role in DCAT planning process. In this study, we systematically evaluated the dosimetric influence caused by the variable grid size and the angular increment in DCAT for lung SBRT. Dose variations with different parameters were estimated for spherical and elongated tumors on an anthropomorphic phantom. The systematic analysis of the generated dose variation would guide to determine appropriate plan parameters and to estimate the dose errors in planning process in a clinical perspective of DCAT. It was found that two plan parameters, grid size and angular increment, in DCAT could cause non-negligible dose uncertainty. Coarse grid size led patients to get unnecessary overdose. Coarse angular increment could make significantly inaccurate prediction of OAR dose, resulting in either over- or under- estimation depending on the location of OAR relative to the isocenter.

  16. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  17. 3D-Conformal Versus Intensity-Modulated Postoperative Radiotherapy of Vaginal Vault: A Dosimetric Comparison

    International Nuclear Information System (INIS)

    Cilla, Savino; Macchia, Gabriella; Digesu, Cinzia; Deodato, Francesco; Romanella, Michele; Ferrandina, Gabriella; Padula, Gilbert; Picardi, Vincenzo; Scambia, Giovanni; Piermattei, Angelo; Morganti, Alessio Giuseppe

    2010-01-01

    We evaluated a step-and-shoot IMRT plan in the postoperative irradiation of the vaginal vault compared with equispaced beam arrangements (3-5) 3D-radiotherapy (RT) optimized plans. Twelve patients were included in this analysis. Four plans for each patient were compared in terms of dose-volume histograms, homogeneity index (HI), and conformity index (CI): (1) 3 equispaced beam arrangement 3D-RT; (2) 4 equispaced beam arrangement 3D-RT; (3) 5 equispaced beam arrangement 3D-RT; (4) step-and-shoot IMRT technique. CI showed a good discrimination between the four plans. The mean scores of CI were 0.58 (range: 0.38-0.67) for the 3F-CRT plan, 0.58 (range: 0.41-0.66) for 4F-CRT, 0.62 (range: 0.43-0.68) for 5F-CRT and 0.69 (range: 0.58-0.78) for the IMRT plan. A significant improvement of the conformity was reached by the IMRT plan (p mean , V90%, V95%, V100% was recorded for rectal and bladder irradiation with the IMRT plan. Surprisingly, IMRT supplied a significant dose reduction also for rectum and bladder V30% and V50%. A significant dosimetric advantage of IMRT over 3D-RT in the adjuvant treatment of vaginal vault alone in terms of treatment conformity and rectum and bladder sparing is shown.

  18. Matched-pair analysis and dosimetric variations of two types of software for interstitial permanent brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ishiyama, Hiromichi, E-mail: hishiyam@kitasato-u.ac.jp [Department of Radiology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan); Nakamura, Ryuji [Department of Radiology, Iwate Medical University, Morioka, Iwate (Japan); Satoh, Takefumi [Department of Urology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan); Tanji, Susumu [Department of Urology, Iwate Medical University, Morioka, Iwate (Japan); Teh, Bin S. [Department of Radiation Oncology, The Methodist Hospital, Houston, TX (United States); Uemae, Mineko [Division of Radiation Oncology, Kitasato University Hospital, Sagamihara, Kanagawa (Japan); Baba, Shiro [Department of Urology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan); Hayakawa, Kazushige [Department of Radiology, Kitasato University School of Medicine, Sagamihara, Kanagawa (Japan)

    2012-04-01

    The purpose of this study was to determine whether identical dosimetric results could be achieved using different planning software for permanent interstitial brachytherapy for prostate cancer. Data from 492 patients treated with brachytherapy were used for matched-pair analysis. Interplant and Variseed were used as software for ultrasound-based treatment planning. Institution, neoadjuvant hormonal therapy, prostate volume, and source strength were used for factors to match the 2 groups. The study population comprised of 126 patients with treatment planning using Interplant software and 127 matched patients using Variseed software. Dosimetric results were compared between the 2 groups. The Variseed group showed significantly higher values for dose covering 90% of prostate volume (pD90), prostate volume covered by 150% of prescription dose (pV150), and dose covering 30% of the urethra (uD30) compared with the Interplant group. Our results showed that use of different software could lead to different dosimetric results, which might affect the clinical outcomes.

  19. Decree of the 17 July 2013 related to the medical supervision form and to the dosimetric follow-up of workers exposed to ionizing radiations

    International Nuclear Information System (INIS)

    Combrexelle, J.D.; Ligeard, C.; Gandil, P.

    2013-01-01

    This legal text addresses the delivery modalities and content of the individual medical supervision form, the implementation modalities and conditions for the reference individual dosimetric follow-up, the implementation modalities and conditions for the operational individual dosimetric follow-up, the access to dosimetry individual results. Appendices address the modalities of the individual dosimetric follow-up, the dosimetry for internal exposure follow-up, the dosimetry for external exposure follow-up, the dosimetry for the follow-up of professional exposure to natural radioactivity, and the technical modalities of information exchange

  20. Dosimetric validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator.

    Science.gov (United States)

    Narayanasamy, Ganesh; Saenz, Daniel L; Defoor, Dewayne; Papanikolaou, Niko; Stathakis, Sotirios

    2017-11-01

    The purpose of this study is to perform dosimetric validation of Monaco treatment planning system version 5.1. The Elekta VersaHD linear accelerator with high dose rate flattening filter-free photon modes and electron energies was used in this study. The dosimetric output of the new Agility head combined with the FFF photon modes warranted this investigation into the dosimetric accuracy prior to clinical usage. A model of the VersaHD linac was created in Monaco TPS by Elekta using commissioned beam data including percent depth dose curves, beam profiles, and output factors. A variety of 3D conformal fields were created in Monaco TPS on a combined Plastic water/Styrofoam phantom and validated against measurements with a calibrated ion chamber. Some of the parameters varied including source to surface distance, field size, wedges, gantry angle, and depth for all photon and electron energies. In addition, a series of step and shoot IMRT, VMAT test plans, and patient plans on various anatomical sites were verified against measurements on a Delta 4 diode array. The agreement in point dose measurements was within 2% for all photon and electron energies in the homogeneous phantom and within 3% for photon energies in the heterogeneous phantom. The mean ± SD gamma passing rates of IMRT test fields yielded 93.8 ± 4.7% based on 2% dose difference and 2 mm distance-to-agreement criteria. Eight previously treated IMRT patient plans were replanned in Monaco TPS and five measurements on each yielded an average gamma passing rate of 95% with 6.7% confidence limit based on 3%, 3 mm gamma criteria. This investigation on dosimetric validation ensures accuracy of modeling VersaHD linac in Monaco TPS thereby improving patient safety. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  1. Toxicity and dosimetric analysis of non-small cell lung cancer patients undergoing radiotherapy with 4DCT and image-guided intensity modulated radiotherapy: a regional centre's experience.

    Science.gov (United States)

    Livingston, Gareth C; Last, Andrew J; Shakespeare, Thomas P; Dwyer, Patrick M; Westhuyzen, Justin; McKay, Michael J; Connors, Lisa; Leader, Stephanie; Greenham, Stuart

    2016-09-01

    For patients receiving radiotherapy for locally advance non-small cell lung cancer (NSCLC), the probability of experiencing severe radiation pneumonitis (RP) appears to rise with an increase in radiation received by the lungs. Intensity modulated radiotherapy (IMRT) provides the ability to reduce planned doses to healthy organs at risk (OAR) and can potentially reduce treatment-related side effects. This study reports toxicity outcomes and provides a dosimetric comparison with three-dimensional conformal radiotherapy (3DCRT). Thirty curative NSCLC patients received radiotherapy using four-dimensional computed tomography and five-field IMRT. All were assessed for early and late toxicity using common terminology criteria for adverse events. All plans were subsequently re-planned using 3DCRT to the same standard as the clinical plans. Dosimetric parameters for lungs, oesophagus, heart and conformity were recorded for comparison between the two techniques. IMRT plans achieved improved high-dose conformity and reduced OAR doses including lung volumes irradiated to 5-20 Gy. One case each of oesophagitis and erythema (3%) were the only Grade 3 toxicities. Rates of Grade 2 oesophagitis were 40%. No cases of Grade 3 RP were recorded and Grade 2 RP rates were as low as 3%. IMRT provides a dosimetric benefit when compared to 3DCRT. While the clinical benefit appears to increase with increasing target size and increasing complexity, IMRT appears preferential to 3DCRT in the treatment of NSCLC.

  2. Comprehensive Australasian multicentre dosimetric intercomparison: issues, logistics and recommendations.

    Science.gov (United States)

    Ebert, M A; Harrison, K M; Cornes, D; Howlett, S J; Joseph, D J; Kron, T; Hamilton, C S; Denham, J W

    2009-02-01

    The present paper describes the logistics of the 2004-2008 Australasian Level III Dosimetry Intercomparison. Dosimetric intercomparisons (or 'audits') can be used in radiotherapy to evaluate the accuracy and quality of radiation delivery. An intercomparison was undertaken in New Zealand and Australia to evaluate the feasibility and logistics of ongoing dosimetric intercomparisons that evaluate all steps in the radiotherapy treatment process, known as a 'Level III' intercomparison. The study commenced in 2002 with the establishment of a study team, definition of the study protocol, acquisition of appropriate equipment and recruitment of participating radiotherapy centres. Measurements were undertaken between October 2004 and March 2008, and included collation of data on time, costs and logistics of the study. Forty independent Australian and New Zealand radiotherapy centres agreed to participate. Measurement visits were made to 37 of these centres. Data is presented on the costs of the study and the level of support required. The study involved the participation of 16 staff at the study centre who invested over 4000 hours in the study, and of over 200 professionals at participating centres. Recommendations are provided for future phantom-based intercomparisons. It is hoped that the present paper will be of benefit to any centres or groups contemplating similar activities by identifying the processes involved in establishing the study, the potential hazards and pitfalls, and expected resource requirements.

  3. Monte Carlo simulations and dosimetric studies of an irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Belchior, A. [Instituto Tecnologico e Nuclear, Estrada nacional no. 10, Apartado 21, 2686-953 Sacavem (Portugal)], E-mail: anabelchior@itn.pt; Botelho, M.L; Vaz, P. [Instituto Tecnologico e Nuclear, Estrada nacional no. 10, Apartado 21, 2686-953 Sacavem (Portugal)

    2007-09-21

    There is an increasing utilization of ionizing radiation for industrial applications. Additionally, the radiation technology offers a variety of advantages in areas, such as sterilization and food preservation. For these applications, dosimetric tests are of crucial importance in order to assess the dose distribution throughout the sample being irradiated. The use of Monte Carlo methods and computational tools in support of the assessment of the dose distributions in irradiation facilities can prove to be economically effective, representing savings in the utilization of dosemeters, among other benefits. One of the purposes of this study is the development of a Monte Carlo simulation, using a state-of-the-art computational tool-MCNPX-in order to determine the dose distribution inside an irradiation facility of Cobalt 60. This irradiation facility is currently in operation at the ITN campus and will feature an automation and robotics component, which will allow its remote utilization by an external user, under REEQ/996/BIO/2005 project. The detailed geometrical description of the irradiation facility has been implemented in MCNPX, which features an accurate and full simulation of the electron-photon processes involved. The validation of the simulation results obtained was performed by chemical dosimetry methods, namely a Fricke solution. The Fricke dosimeter is a standard dosimeter and is widely used in radiation processing for calibration purposes.

  4. SU-G-206-16: Investigation of Dosimetric Consequence Via Cone-Beam CT Based Dose Reconstruction in Hepatocellular Carcinoma Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, P; Gang, Y; Qin, S; Li, D [Shandong Province Key Laboratory of Medical Physics and Image Processing Technology, School of Physics and Electronics, Shandong Normal University (China); Li, H; Chen, J; Ma, C; Yin, Y [Department of Radiation Oncology, Shandong Cancer Hospital and Institute (China)

    2016-06-15

    Purpose: Many patients with technically unresectable or medically inoperable hepatocellular carcinoma (HCC) had hepatic dosimetric variations as a result of inter-fraction anatomical deformation. This study was conducted to assess the hepatic dosimetric consequences via reconstructing weekly dose in HCC patients receiving three dimensional conformal radiation therapy. Methods: Twenty-one HCC patients with 21 planning CT (pCT) scans and 63 weekly Cone-beam CT (CBCT) scans were enrolled in this investigation. Among them, six patients had been diagnosed of radiation induced liver disease (RILD) and the other fifteen patients had good prognosis after treatment. And each patient had three weekly CBCT before re-planning. In reconstructing CBCT-based weekly dose, we registered pCT to CBCT to provide the correct Hounsfield units for the CBCT using gradient-based deformable image registration (DIR), and this modified CBCT (mCBCT) were introduced to enable dose calculation.To obtain the weekly dosimetric consequences, the initial plan beam configurations and dose constraints were re-applied to mCBCT for performing dose calculation, and the mCBCT were extrapolated to 25 fractions. Besides, the manually delineated contour was propagated automatically onto the mCBCT of the new patient by exploiting the deformation vectors field, and the reconstructed weekly dose was mapped back to pCT to understand the dose distribution difference. Also, weekly dosimetric variations were compared with the hepatic radiation tolerance in terms of D50 and Dmean. Results: Among the twenty-one patients, the three weekly D50 increased by 0.7Gy, 5.1Gy and 6.1Gy, respectively, and Dmean increased by 0.9%, 4.7% and 5.5%, respectively. For patients with RILD, the average values of the third weekly D50 and Dmean were both high than hepatic radiation tolerance, while the values of patients without RILD were below. Conclusion: The planned dose on pCT was not a real dose to the liver, and the liver overdose

  5. Sensitization of glycine (spectrophotometric read-out) dosimetric system using sorbitol

    International Nuclear Information System (INIS)

    Shinde, S.H.; Mukherjee, T.

    2009-01-01

    Glycine spectrophotometric read-out systems have a useful dose range of 15-4000 Gy. An attempt was made to sensitize it using sorbitol as a sensitizer. Optimum compositions of aqueous acidic solutions of ferrous ammonium sulphate-xylenol orange (XO), i.e. FX and sorbitol-ferrous ammonium sulphate-xylenol orange, i.e. SFX, for 400 mg of glycine, which gives maximum dosimetric response for any given dose, were established. Molar absorption coefficient values of ferric-XO-glycine complex, i.e. ε-values, were determined for glycine system in FX and SFX. These values were found to be 8410 and 15,000 m 2 mol -1 respectively, indicating that an enhancement or sensitivity factor of about 1.78 can be achieved by sorbitol for glycine in SFX. This factor was further confirmed by measuring the gamma dose response of glycine in FX and in SFX for four different doses, viz. 37.8, 75.5, 151 and 302 Gy. It was observed that dose response of glycine in SFX is about 77% more than that of glycine in FX. The maximum variation observed in response of glycine in FX or SFX was found to be within ±1.5%.

  6. Dosimetric impact of prostate volume change between CT-based HDR brachytherapy fractions

    International Nuclear Information System (INIS)

    Kim, Yongbok; Hsu, I-C.; Lessard, Etienne; Vujic, Jasmina; Pouliot, Jean

    2004-01-01

    Purpose: The objective is to evaluate the prostate volume change and its dosimetric consequences after the insertion of catheters for high-dose-rate brachytherapy. Methods and Materials: For 13 consecutive patients, a spiral CT scan was acquired before each of the 2 fractions, separated on average by 20 hours. The coordinates of the catheters were obtained on 3 axial CT slices corresponding to apex, mid portion, and base portion of the prostate. A mathematical expansion model was used to evaluate the change of prostate volumes between the 2 fractions. It is based on the difference in the cube of the average distance between the centroid and catheter positions. The variation of implant dose-volume histograms between fractions was computed for plans produced by either inverse planning based on simulated annealing or geometric optimization. Results: The average magnitude of either increase or reduction in prostate volume was 7.8% (range, 2-17%). This volume change corresponds to an average prostate radius change of only 2.5% (range, 0.7-5.4%). For 5 patients, the prostate volume increased on average by 9% (range, 2-17%), whereas a reduction was observed for 8 patients by an average of 7% (range, 2-13%). More variation was observed at the prostate base than at mid or apex gland. The comparison of implant dose-volume histograms showed a small reduction of V100 receiving the prescription dose, with an average of 3.5% (range, 0.5-12%) and 2.2% (range, 1-6%) for inverse planning based on our simulated annealing and geometric optimization plans, respectively. Conclusion: Small volume change was observed between treatment fractions. This translates into small changes in dose delivered to the prostate volume

  7. Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy

    Science.gov (United States)

    Pommer, Tobias; Falk, Marianne; Poulsen, Per R.; Keall, Paul J.; O'Brien, Ricky T.; Meidahl Petersen, Peter; Rosenschöld, Per Munck af

    2013-04-01

    This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 s. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7-100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7-99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with >3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf position

  8. Study on dosimetric properties of radiophotoluminescent glass rod detector

    Energy Technology Data Exchange (ETDEWEB)

    Rah, Jeong Eun; Hong, Ju Young; Suh, Tea Suk [The Catholic University of Korea, Seoul (Korea, Republic of); Shin, Dong Oh [Kyunghee Univ., Seoul (Korea, Republic of); Kim, Hee Sun [Korea Hydro and Nuclear Power Co., Ltd, Daejeon (Korea, Republic of); Lim, Chun Il; Jeong, Hee Gyo [Korea Food and Drug Administration, Seoul (Korea, Republic of)

    2006-12-15

    A radiophotoluminescent Glass Rod Detector (GRD) system has recently become commercially available. We investigate the dosimetric properties of the GRD regarding the reproducibility of signal, dose linearity and energy dependence. The reproducibility of five measurements for 50 GRDs is presented by an average of one standard deviation of each GRD and it is {+-}1.2%. It is found to be linear in response to doses of {sup 60}Co beam in the range 0.5 to 50 Gy with a coefficient of linearity of 0.9998. The energy dependence of the GRD is determined by comparing the dose obtained using cylindrical chamber to that by using the GRD. The GRD response for each beam is normalized to the response for a {sup 60}Co beam. The responses for 6 and 15 MV x-ray beams are within {+-}1.5% (1SD). The energy response of GRD for high-energy photon is almost the same as the energy dependence of LiF:Mg:Ti (TLD-100) and shows little energy dependence unlike p-type silicon diode detector. The GRDs have advantages over other detectors such diode detector, and TLD: linearity, reproducibility and energy dependency. It has been verified to be an effective device for small field dosimetry for stereotactic radiosurgery.

  9. Weekly Volume and Dosimetric Changes During Chemoradiotherapy With Intensity-Modulated Radiation Therapy for Head and Neck Cancer: A Prospective Observational Study

    Energy Technology Data Exchange (ETDEWEB)

    Bhide, Shreerang A [Institute of Cancer Research, 237 Fulham Road, London SW6 6JB (United Kingdom); Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Davies, Mark; Burke, Kevin; McNair, Helen A; Hansen, Vibeke [Department of Radiation Oncology, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); Barbachano, Y [Department of Statistics, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); El-Hariry, I A [Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Newbold, Kate [Department of Radiation Oncology, Royal Marsden NHS Foundation Trust Hospital, London and Sutton (United Kingdom); Harrington, Kevin J [Institute of Cancer Research, 237 Fulham Road, London SW6 6JB (United Kingdom); Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom); Nutting, Christopher M., E-mail: chris.nutting@rmh.nhs.u [Head and Neck Unit, Royal Marsden NHS Foundation Trust Hospital, London SW3 6JJ (United Kingdom)

    2010-04-15

    Purpose: The aim of this study was to investigate prospectively the weekly volume changes in the target volumes and organs at risk and the resulting dosimetric changes during induction chemotherapy followed by chemoradiotherapy with intensity-modulated radiation therapy (C-IMRT) for head-and-neck cancer patients. Methods and Materials: Patients receiving C-IMRT for head-and-neck cancer had repeat CT scans at weeks 2, 3, 4, and 5 during radiotherapy. The volume changes of clinical target volume 1 (CTV1) and CTV2 and the resulting dosimetric changes to planning target volume 1 (PTV1) and PTV2 and the organs at risk were measured. Results: The most significant volume differences were seen at week 2 for CTV1 and CTV2. The reductions in the volumes of CTV1 and CTV2 at week 2 were 3.2% and 10%, respectively (p = 0.003 and p < 0.001). The volume changes resulted in a significant reduction in the minimum dose to PTV1 and PTV2 (2 Gy, p = 0.002, and 3.9 Gy, p = 0.03, respectively) and an increased dose range across PTV1 and PTV2 (2.5 Gy, p < 0.001, and 5.1 Gy, p = 0.008, respectively). There was a 15% reduction in the parotid volumes by week 2 (p < 0.001) and 31% by week 4 (p < 0.001). There was a statistically significant increase in the mean dose to the ipsilateral parotid only at week 4 (2.7 Gy, p = 0.006). The parotid glands shifted medially by an average of 2.3 mm (p < 0.001) by week 4. Conclusion: The most significant volumetric changes and dosimetric alterations in the tumor volumes and organs at risk during a course of C-IMRT occur by week 2 of radiotherapy. Further adaptive radiotherapy with replanning, if appropriate, is recommended.

  10. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value

    International Nuclear Information System (INIS)

    Kueppers, C.; Sering, M.; Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F.

    2012-01-01

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  11. Evaluation of specific absorption rate as a dosimetric quantity for electromagnetic fields bioeffects.

    Directory of Open Access Journals (Sweden)

    Dimitris J Panagopoulos

    Full Text Available PURPOSE: To evaluate SAR as a dosimetric quantity for EMF bioeffects, and identify ways for increasing the precision in EMF dosimetry and bioactivity assessment. METHODS: We discuss the interaction of man-made electromagnetic waves with biological matter and calculate the energy transferred to a single free ion within a cell. We analyze the physics and biology of SAR and evaluate the methods of its estimation. We discuss the experimentally observed non-linearity between electromagnetic exposure and biological effect. RESULTS: WE FIND THAT: a The energy absorbed by living matter during exposure to environmentally accounted EMFs is normally well below the thermal level. b All existing methods for SAR estimation, especially those based upon tissue conductivity and internal electric field, have serious deficiencies. c The only method to estimate SAR without large error is by measuring temperature increases within biological tissue, which normally are negligible for environmental EMF intensities, and thus cannot be measured. CONCLUSIONS: SAR actually refers to thermal effects, while the vast majority of the recorded biological effects from man-made non-ionizing environmental radiation are non-thermal. Even if SAR could be accurately estimated for a whole tissue, organ, or body, the biological/health effect is determined by tiny amounts of energy/power absorbed by specific biomolecules, which cannot be calculated. Moreover, it depends upon field parameters not taken into account in SAR calculation. Thus, SAR should not be used as the primary dosimetric quantity, but used only as a complementary measure, always reporting the estimating method and the corresponding error. Radiation/field intensity along with additional physical parameters (such as frequency, modulation etc which can be directly and in any case more accurately measured on the surface of biological tissues, should constitute the primary measure for EMF exposures, in spite of similar

  12. Evaluation of specific absorption rate as a dosimetric quantity for electromagnetic fields bioeffects.

    Science.gov (United States)

    Panagopoulos, Dimitris J; Johansson, Olle; Carlo, George L

    2013-01-01

    To evaluate SAR as a dosimetric quantity for EMF bioeffects, and identify ways for increasing the precision in EMF dosimetry and bioactivity assessment. We discuss the interaction of man-made electromagnetic waves with biological matter and calculate the energy transferred to a single free ion within a cell. We analyze the physics and biology of SAR and evaluate the methods of its estimation. We discuss the experimentally observed non-linearity between electromagnetic exposure and biological effect. WE FIND THAT: a) The energy absorbed by living matter during exposure to environmentally accounted EMFs is normally well below the thermal level. b) All existing methods for SAR estimation, especially those based upon tissue conductivity and internal electric field, have serious deficiencies. c) The only method to estimate SAR without large error is by measuring temperature increases within biological tissue, which normally are negligible for environmental EMF intensities, and thus cannot be measured. SAR actually refers to thermal effects, while the vast majority of the recorded biological effects from man-made non-ionizing environmental radiation are non-thermal. Even if SAR could be accurately estimated for a whole tissue, organ, or body, the biological/health effect is determined by tiny amounts of energy/power absorbed by specific biomolecules, which cannot be calculated. Moreover, it depends upon field parameters not taken into account in SAR calculation. Thus, SAR should not be used as the primary dosimetric quantity, but used only as a complementary measure, always reporting the estimating method and the corresponding error. Radiation/field intensity along with additional physical parameters (such as frequency, modulation etc) which can be directly and in any case more accurately measured on the surface of biological tissues, should constitute the primary measure for EMF exposures, in spite of similar uncertainty to predict the biological effect due to non-linearity.

  13. Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system

    Energy Technology Data Exchange (ETDEWEB)

    Kalet, Alan M., E-mail: amkalet@uw.edu [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Seattle Cancer Care Alliance, Seattle, Washington (United States); Richardson, Hannah L.; Nikolaisen, Darrin A. [Seattle Cancer Care Alliance, Seattle, Washington (United States); Cao, Ning [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Seattle Cancer Care Alliance, Seattle, Washington (United States); Lavilla, Myra A. [Seattle Cancer Care Alliance, Seattle, Washington (United States); Dempsey, Claire; Meyer, Juergen; Koh, Wui-Jin; Russell, Kenneth J. [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Seattle Cancer Care Alliance, Seattle, Washington (United States)

    2017-07-01

    The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. We selected for this study a total of 17 previously treated patients with a range of pelvic disease sites including prostate (9), bladder (1), uterus (3), rectum (3), and cervix (1). For each patient, 2 plans were generated, one using an arc-per-beam setting of “1” and another with an arc-per-beam setting of “2” using the volumes and constraints established from the initial clinical treatments. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the planning target volume (PTV) received 95% of the prescription dose. Plans were evaluated for PTV conformity, homogeneity, number of monitor units, number of control points, and overall plan acceptability. Treatment delivery time, patient-specific quality assurance procedures, and the impact on clinical workflow were also assessed. We found that for complex-shaped target volumes (small central volumes with extending arms to cover nodal regions), the use of 2 arc-per-beam (2APB) parameter setting achieved significantly lower average dose-volume histogram values for the rectum V{sub 20} (p = 0.0012) and bladder V{sub 30} (p = 0.0036) while meeting the high dose target constraints. For simple PTV shapes, we found reduced monitor units (13.47%, p = 0.0009) and control points (8.77%, p = 0.0004) using 2APB planning. In addition, we found a beam delivery time reduction of approximately 25%. In summary, the dosimetric benefit, although moderate, was improved over a 1APB setting for complex PTV, and equivalent in other cases. The overall reduced delivery time suggests that the use of mulitple arcs per beam could lead to reduced patient-on-table time, increased clinical throughput, and reduced medical physics quality assurance

  14. Chemo-IMRT of Oropharyngeal Cancer Aiming to Reduce Dysphagia: Swallowing Organs Late Complication Probabilities and Dosimetric Correlates

    International Nuclear Information System (INIS)

    Eisbruch, Avraham; Kim, Hyungjin M.; Feng, Felix Y.; Lyden, Teresa H.; Haxer, Marc J.; Feng, Mary; Worden, Frank P.; Bradford, Carol R.; Prince, Mark E.; Moyer, Jeffrey S.; Wolf, Gregory T.; Chepeha, Douglas B.; Ten Haken, Randall K.

    2011-01-01

    Purpose: Assess dosimetric correlates of long-term dysphagia after chemo-intensity-modulated radiotherapy (IMRT) of oropharyngeal cancer (OPC) sparing parts of the swallowing organs. Patients and Methods: Prospective longitudinal study: weekly chemotherapy concurrent with IMRT for Stages III/IV OPC, aiming to reduce dysphagia by sparing noninvolved parts of swallowing-related organs: pharyngeal constrictors (PC), glottic and supraglottic larynx (GSL), and esophagus, as well as oral cavity and major salivary glands. Dysphagia outcomes included patient-reported Swallowing and Eating Domain scores, Observer-based (CTCAEv.2) dysphagia, and videofluoroscopy (VF), before and periodically after therapy through 2 years. Relationships between dosimetric factors and worsening (from baseline) of dysphagia through 2 years were assessed by linear mixed-effects model. Results: Seventy-three patients participated. Observer-based dysphagia was not modeled because at >6 months there were only four Grade ≥2 cases (one of whom was feeding-tube dependent). PC, GSL, and esophagus mean doses, as well as their partial volume doses (V D s), were each significantly correlated with all dysphagia outcomes. However, the V D s for each organ intercorrelated and also highly correlated with the mean doses, leaving only mean doses significant. Mean doses to each of the parts of the PCs (superior, middle, and inferior) were also significantly correlated with all dysphagia measures, with superior PCs demonstrating highest correlations. For VF-based strictures, most significant predictor was esophageal mean doses (48±17 Gy in patients with, vs 27±12 in patients without strictures, p = 0.004). Normal tissue complication probabilities (NTCPs) increased moderately with mean doses without any threshold. For increased VF-based aspirations or worsened VF summary scores, toxic doses (TDs) 50 and TD 25 were 63 Gy and 56 Gy for PC, and 56 Gy and 39 Gy for GSL, respectively. For both PC and GSL, patient

  15. Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer

    International Nuclear Information System (INIS)

    Kim, Yongbok; Parda, David S.; Trombetta, Mark G.; Colonias, Athanasios; Werts, E. Day; Miller, Linda; Miften, Moyed

    2007-01-01

    A dosimetric comparison was performed on external-beam three-dimensional conformal partial breast irradiation (PBI) and whole breast irradiation (WBI) plans for patients enrolled in the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol at our institution. Twenty-four consecutive patients were treated with either PBI (12 patients) or WBI (12 patients). In the PBI arm, the lumpectomy cavity was treated to a total dose of 38.5 Gy at 3.85 Gy per fraction twice daily using a four-field noncoplanar beam setup. A minimum 6 h interval was required between fractions. In the WBI arm, the whole breast including the entirety of the lumpectomy cavity was treated to a total dose of 50.4 Gy at 1.8 Gy per fraction daily using opposed tangential beams. The lumpectomy cavity volume, planning target volume for evaluation (PTV E VAL), and critical structure volumes were contoured for both the PBI and WBI patients. Dosimetric parameters, dose volume histograms (DVHs), and generalized equivalent uniform dose (gEUD) for target and critical structures were compared. Dosimetric results show the PBI plans, compared to the WBI plans, have smaller hot spots in the PTV E VAL (maximum dose: 104.2% versus 110.9%) and reduced dose to the ipsilateral breast (V50: 48.6% versus 92.1% and V100: 10.2% versus 50.5%), contralateral breast (V3: 0.16% versus 2.04%), ipsilateral lung (V30: 5.8% versus 12.7%), and thyroid (maximum dose: 0.5% versus 2.0%) with p values ≤0.01. However, similar dose coverage of the PTV E VAL (98% for PBI and 99% for WBI, on average) was observed and the dose difference for other critical structures was clinically insignificant in both arms. The gEUD data analysis showed the reduction of dose to the ipsilateral breast and lung, contralateral breast and thyroid. In addition, preliminary dermatologic adverse event assessment data suggested reduced skin toxicity for patients treated with the PBI technique

  16. Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans

    International Nuclear Information System (INIS)

    Kroon, Petra S; Hol, Sandra; Essers, Marion

    2013-01-01

    The main aim of the current study was to assess the dosimetric accuracy and clinical quality of volumetric modulated arc therapy (VMAT) plans for stereotactic (stage I) and conventional (stage III) lung cancer treatments planned with Eclipse version 10.0 Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithm. The dosimetric impact of using AAA instead of AXB, and grid size 2.5 mm instead of 1.0 mm for VMAT treatment plans was evaluated. The clinical plan quality of AXB VMAT was assessed using 45 stage I and 73 stage III patients, and was compared with published results, planned with VMAT and hybrid-VMAT techniques. The dosimetric impact on near-minimum PTV dose (D 98% ) using AAA instead of AXB was large (underdose up to 12.3%) for stage I and very small (underdose up to 0.8%) for stage III lung treatments. There were no significant differences for dose volume histogram (DVH) values between grid sizes. The calculation time was significantly higher for AXB grid size 1.0 than 2.5 mm (p < 0.01). The clinical quality of the VMAT plans was at least comparable with clinical qualities given in literature of lung treatment plans with VMAT and hybrid-VMAT techniques. The average mean lung dose (MLD), lung V 20Gy and V 5Gy in this study were respectively 3.6 Gy, 4.1% and 15.7% for 45 stage I patients and 12.4 Gy, 19.3% and 46.6% for 73 stage III lung patients. The average contra-lateral lung dose V 5Gy-cont was 35.6% for stage III patients. For stereotactic and conventional lung treatments, VMAT calculated with AXB grid size 2.5 mm resulted in accurate dose calculations. No hybrid technique was needed to obtain the dose constraints. AXB is recommended instead of AAA for avoiding serious overestimation of the minimum target doses compared to the actual delivered dose

  17. Dosimetric properties of dysprosium doped lithium borate glass irradiated by 6 MV photons

    Science.gov (United States)

    Ab Rasid, A.; Wagiran, H.; Hashim, S.; Ibrahim, Z.; Ali, H.

    2015-07-01

    Undoped and dysprosium doped lithium borate glass system with empirical formula (70-x) B2O3-30 Li2O-(x) Dy2O3 (x=0.1, 0.3, 0.5, 0.7, 1.0 mol%) were prepared using the melt-quenching technique. The dosimetric measurements were performed by irradiating the samples to 6 MV photon beam using linear accelerator (LINAC) over a dose range of 0.5-5.0 Gy. The glass series of dysprosium doped lithium borate glass produced the best thermoluminescence (TL) glow curve with the highest intensity peak from sample with 1.0 mol% Dy2O3 concentration. Minimum detectable dose was detected at 2.24 mGy, good linearity of regression coefficient, high reproducibility and high sensitivity compared to the undoped glass are from 1.0 mol% dysprosium doped lithium borate glass. The results indicated that the series of dysprosium doped lithium glasses have a great potential to be considered as a thermoluminescence dosimetry (TLD).

  18. Dosimetric analysis of urethral strictures following HDR 192Ir brachytherapy as monotherapy for intermediate- and high-risk prostate cancer

    International Nuclear Information System (INIS)

    Díez, Patricia; Mullassery, Vinod; Dankulchai, Pittaya; Ostler, Peter; Hughes, Robert; Alonzi, Roberto; Lowe, Gerry; Hoskin, Peter J.

    2014-01-01

    Background and purpose: To evaluate dosimetric parameters related to urethral strictures following high dose-rate brachytherapy (HDRBT) alone for prostate cancer. Material and methods: Ten strictures were identified in 213 patients treated with HDRBT alone receiving 34 Gy in four fractions, 36 Gy in four fractions, 31.5 Gy in 3 fractions or 26 Gy in 2 fractions. A matched-pair analysis used 2 controls for each case matched for dose fractionation schedule, pre-treatment IPSS score, number of needles used and clinical target volume. The urethra was divided into membranous urethra and inferior, mid and superior thirds of the prostatic urethra. Results: Stricture rates were 3% in the 34 Gy group, 4% in the 36 Gy group, 6% in the 31.5 Gy group and 4% in the 26 Gy group. The median time to stricture formation was 26 months (range 8–40). The dosimetric parameters investigated were not statistically different between cases and controls. No correlation was seen between stricture rate and fractionation schedule. Conclusions: Urethral stricture is an infrequent complication of prostate HDRBT when used to deliver high doses as sole treatment, with an overall incidence in this cohort of 10/213 (4.7%). In a matched pair analysis no association with dose schedule or urethral dosimetry was identified, but the small number of events limits definitive conclusions

  19. A dosimetric comparison of two-phase adaptive intensity-modulated radiotherapy for locally advanced nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Chitapanarux, Imjai; Chomprasert, Kittisak; Nobnaop, Wannapa; Wanwilairat, Somsak; Tharavichitkul, Ekasit; Jakrabhandu, Somvilai; Onchan, Wimrak; Patrinee, Traisathit; Gestel, Dirk Van

    2015-01-01

    The purpose of this investigation was to evaluate the potential dosimetric benefits of a two-phase adaptive intensity-modulated radiotherapy (IMRT) protocol for patients with locally advanced nasopharyngeal cancer (NPC). A total of 17 patients with locally advanced NPC treated with IMRT had a second computed tomography (CT) scan after 17 fractions in order to apply and continue the treatment with an adapted plan after 20 fractions. To simulate the situation without adaptation, a hybrid plan was generated by applying the optimization parameters of the original treatment plan to the anatomy of the second CT scan. The dose-volume histograms (DVHs) and dose statistics of the hybrid plan and the adapted plan were compared. The mean volume of the ipsilateral and contralateral parotid gland decreased by 6.1 cm 3 (30.5%) and 5.4 cm 3 (24.3%), respectively. Compared with the hybrid plan, the adapted plan provided a higher dose to the target volumes with better homogeneity, and a lower dose to the organs at risk (OARs). The Dmin of all planning target volumes (PTVs) increased. The Dmax of the spinal cord and brainstem were lower in 94% of the patients (1.6-5.9 Gy, P < 0.001 and 2.1-9.9 Gy, P < 0.001, respectively). The D mean of the contralateral parotid decreased in 70% of the patients (range, 0.2-4.4 Gy). We could not find a relationship between dose variability and weight loss. Our two-phase adaptive IMRT protocol improves dosimetric results in terms of target volumes and OARs in patients with locally advanced NPC. (author)

  20. Dosimetric aspects of the treatment of metastatic bone pain with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Garcia, T.; Marti, J. F.; Olivas, C.; Vercher, J. L.; Repetto, R.; Bello, P.

    2014-01-01

    Within the context of treatment of metastatic bone pain with bone seeking radiopharmaceuticals, this paper expounds the results of an analysis of available molecules (both approved for clinical use or still under study) intended to obtain a detailed comparison of their dosimetric characteristics. These can be used to supplement the list of already know differences between them, such as efficacy, appearance and length of the palliative effect, eventual tumoricidal effect, myelotoxicity, sale price and availability. Seven radiopharmaceuticals have been analysed, five of them are based on beta emission radionuclides: 3 2P, 1 53Sm, 1 86Re and 1 88Re and the other two ones are based on high Linear energy Transference emission radionuclides: 1 17mSn and 2 23Ra a series of estimates of the main dosimetric parameters for each radiopharmaceutical analysed have been obtained. The values obtained might be worth being incorporated to the risk/benefit analysis that precedes every choice of the specific radiopharmaceutical to be used with an individual patient. In this way, we hope these results will be of some help for those Nuclear Medicine specialists interested in the treatment of oncological bone pathologies. (Author)

  1. On the use of advanced numerical models for the evaluation of dosimetric parameters and the verification of exposure limits at workplaces.

    Science.gov (United States)

    Catarinucci, L; Tarricone, L

    2009-12-01

    With the next transposition of the 2004/40/EC Directive, employers will become responsible for the electromagnetic field level at the workplace. To make this task easier, the scientific community is compiling practical guidelines to be followed. This work aims at enriching such guidelines, especially for the dosimetric issues. More specifically, some critical aspects related to the application of numerical dosimetric techniques for the verification of the safety limit compliance have been highlighted. In particular, three different aspects have been considered: the dosimetric parameter dependence on the shape and the inner characterisation of the exposed subject as well as on the numerical algorithm used, and the correlation between reference limits and basic restriction. Results and discussions demonstrate how, even by using sophisticated numerical techniques, in some cases a complex interpretation of the result is mandatory.

  2. Dosimetric characterization of VIPARnd gel by optical analysis to high-energy photon beam used in external radiotherapy

    International Nuclear Information System (INIS)

    Dias, Juliana R.; Lima, Renata S.; Lopes, Roseany de V. Vieira; Ceschin, Artemis Marti

    2015-01-01

    Polymer gel dosimetry has been proposed as a possibility for measurements of dose distribution in radiotherapy. This work aims to evaluate the dosimetric characteristics of a VIPARnd for 6 MV photon beam used in radiotherapy using optical investigations. The absorbance spectrum of irradiated gel dosimeter was optical evaluated with spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose-response curve for blue component showed interval of linearity from 1 Gy to 20 Gy. (author)

  3. Dosimetric analysis of imaging changes following pulmonary stereotactic body radiation therapy.

    Science.gov (United States)

    Prendergast, Brendan M; Bonner, James A; Popple, Richard A; Spencer, Sharon A; Fiveash, John B; Keene, Kimberly S; Cerfolio, Robert J; Minnich, Douglas J; Dobelbower, Michael C

    2011-02-01

    The aim of this study was to determine whether late patterns of pulmonary fibrosis are related to specific radiation doses administered during thoracic stereotactic body radiation therapy (SBRT). The records of all patients treated with SBRT for either pulmonary metastases or inoperable primary lung tumours at the University of Alabama at Birmingham from November 2005 to July 2008 were reviewed. Patients selected for analysis had diagnostic chest computed tomography (CT) scans acquired at least 180 days after completion of therapy. CT scans acquired at follow-up were co-registered with the original treatment planning CT scans for 12 eligible patients (17 lesions), and late-occurring pulmonary imaging abnormalities (IAs) were contoured. Dosimetric parameters analysed include D(80) , D(90) , V(18) and V(prescription dose) of the IA and V(14) and V(18) of the lung. Late pulmonary IAs were identified in 11 treated areas from nine patients. Late IAs could not be identified in six treated areas from three patients secondary to emphysema, tumour progression and severe atelectasis, respectively. The mean doses to 80% (D(80) ) and 90% (D(90) ) of the IAs were 18.4 and 14.5 Gy, respectively (ranges: 5.6-27.8 and 3.3-22.4 Gy). On average, 79.4% (range: 45.6-97.5%) of the IA received at least 18 Gy, while an average of 19.3% (range: 0.2-42.2%) received the prescription dose. On average, only 4.2% (range: 1.1-7.8%) of the lungs received 18 Gy. Imaging abnormalities consistent with pulmonary fibrosis are common after SBRT and are well approximated by the 18 Gy isodose distribution. The clinical ramification of these findings should be evaluated in future studies. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

  4. TU-AB-BRA-11: Indications for Online Adaptive Radiotherapy Based On Dosimetric Consequences of Interfractional Pancreas-To-Duodenum Motion in MRI-Guided Pancreatic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mittauer, K; Rosenberg, S; Geurts, M; Bassetti, M; Wojcieszynski, A; Harari, P; Labby, Z; Hill, P; Paliwal, B; Bayouth, J [University of Wisconsin, School of Medicine and Public Health, Madison, WI (United States); Chen, I; Henke, L; Kashani, R; Parikh, P [Washington University School of Medicine, St. Louis, MO (United States); Olsen, J [University of Colorado- Denver, Aurora, CO (United States)

    2016-06-15

    Purpose: Dose limiting structures, such as the duodenum, render the treatment of pancreatic cancer challenging. In this multi-institutional study, we assess dosimetric differences caused by interfraction pancreas-to-duodenum motion using MR-IGRT to determine the potential impact of adaptive replanning. Methods: Ten patients from two institutions undergoing MRI-guided radiotherapy with conventional fractionation (n=5) or SBRT (n=5) for pancreatic cancer were included. Initial plans were limited by duodenal dose constraints of 50 Gy (0.5 cc)/31 Gy (0.1 cc) for conventional/SBRT with prescriptions of 30 Gy/5 fractions (SBRT) and 40–50 Gy/25 fractions (conventional). Daily volumetric MR images were acquired under treatment conditions on a clinical MR-IGRT system. The correlation was assessed between interfractional GTV-to-duodenum positional variation and daily recalculations of duodenal dose metrics. Positional variation was quantified as the interfraction difference in Hausdorff distance from simulation baseline (ΔHD) between the GTV and proximal duodenal surface, or volume overlap between GTV and duodenum for cases with HD{sub 0}=0 (GTV abutting duodenum). Adaptation was considered indicated when daily positional variations enabled dose escalation to the target while maintaining duodenal constraints. Results: For fractions with ΔHD>0 (n=14, SBRT only), the mean interfraction duodenum dose decrease from simulation to treatment was 44±53 cGy (maximum 136 cGy). A correlation was found between ΔHD and dosimetric difference (R{sup 2}=0.82). No correlation was found between volume of overlap and dosimetric difference (R{sup 2}=0.31). For 89% of fractions, the duodenum remained overlapped with the target and the duodenal dose difference was negligible. The maximum observed indication for adaptation was for interfraction ΔHD=11.6 mm with potential for adaptive dose escalation of 136 cGy. Conclusion: This assessment showed that Hausdorff distance was a reasonable

  5. TU-AB-BRA-11: Indications for Online Adaptive Radiotherapy Based On Dosimetric Consequences of Interfractional Pancreas-To-Duodenum Motion in MRI-Guided Pancreatic Radiotherapy

    International Nuclear Information System (INIS)

    Mittauer, K; Rosenberg, S; Geurts, M; Bassetti, M; Wojcieszynski, A; Harari, P; Labby, Z; Hill, P; Paliwal, B; Bayouth, J; Chen, I; Henke, L; Kashani, R; Parikh, P; Olsen, J

    2016-01-01

    Purpose: Dose limiting structures, such as the duodenum, render the treatment of pancreatic cancer challenging. In this multi-institutional study, we assess dosimetric differences caused by interfraction pancreas-to-duodenum motion using MR-IGRT to determine the potential impact of adaptive replanning. Methods: Ten patients from two institutions undergoing MRI-guided radiotherapy with conventional fractionation (n=5) or SBRT (n=5) for pancreatic cancer were included. Initial plans were limited by duodenal dose constraints of 50 Gy (0.5 cc)/31 Gy (0.1 cc) for conventional/SBRT with prescriptions of 30 Gy/5 fractions (SBRT) and 40–50 Gy/25 fractions (conventional). Daily volumetric MR images were acquired under treatment conditions on a clinical MR-IGRT system. The correlation was assessed between interfractional GTV-to-duodenum positional variation and daily recalculations of duodenal dose metrics. Positional variation was quantified as the interfraction difference in Hausdorff distance from simulation baseline (ΔHD) between the GTV and proximal duodenal surface, or volume overlap between GTV and duodenum for cases with HD_0=0 (GTV abutting duodenum). Adaptation was considered indicated when daily positional variations enabled dose escalation to the target while maintaining duodenal constraints. Results: For fractions with ΔHD>0 (n=14, SBRT only), the mean interfraction duodenum dose decrease from simulation to treatment was 44±53 cGy (maximum 136 cGy). A correlation was found between ΔHD and dosimetric difference (R"2=0.82). No correlation was found between volume of overlap and dosimetric difference (R"2=0.31). For 89% of fractions, the duodenum remained overlapped with the target and the duodenal dose difference was negligible. The maximum observed indication for adaptation was for interfraction ΔHD=11.6 mm with potential for adaptive dose escalation of 136 cGy. Conclusion: This assessment showed that Hausdorff distance was a reasonable metric to use to

  6. ESR Spectra of Some Silicate Minerals: A Search For New Dosimetric Materials

    International Nuclear Information System (INIS)

    Abdel-Monem, A.A.; Abdel-Razek, Y.A.; Rasheed, G. M.; Hassan, G.M.; Eissa, H.M.; Morsy, M.

    2008-01-01

    Two silicate minerals talc (Mg 3 Si 4 O 1 0 (OH) 2 ) and zircon (ZrSiO 4 ) having different crystal lattice structures were subjected to ESR dosimetric studies. Zircon shows anisotropic ESR signals at g xx =2.0168, g yy =2.0076 and g zz =2.0033, which have been identified as a hole center associated with Y 3+ substituted at Zr 4+ sites. Other characteristic signals have been observed and identified. The ESR signal at g=2.0033 showed positive response to γ-irradiation at 110 Gy and is suitable to be used for dosimetry and dating of natural zircons. Talc a magnesium sheeted silicate exhibits ESR derivative spectrum characterized the presence of Fe 3+ at g=4.28 and the HF-sixtet Mn 2+ signals due to possible substitution of Fe 3+ and Mn 2+ in the Mg 2+ octahedral sites, respectively. The enhancement of the Mn 2+ sixtet by γ-irradiation increases the area occupied by the signals which makes it difficult to use for dosimetric applications

  7. A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Alfonso, J. C. L.; Herrero, M. A.; Núñez, L.

    2015-01-01

    The choice of any radiotherapy treatment plan is usually made after the evaluation of a few preliminary isodose distributions obtained from different beam configurations. Despite considerable advances in planning techniques, such final decision remains a challenging task that would greatly benefit from efficient and reliable assessment tools. For any dosimetric plan considered, data on dose-volume histograms supplied by treatment planning systems are used to provide estimates on planning target coverage as well as on sparing of organs at risk and the remaining healthy tissue. These partial metrics are then combined into a dose distribution index (DDI), which provides a unified, easy-to-read score for each competing radiotherapy plan. To assess the performance of the proposed scoring system, DDI figures for fifty brain cancer patients were retrospectively evaluated. Patients were divided in three groups depending on tumor location and malignancy. For each patient, three tentative plans were designed and recorded during planning, one of which was eventually selected for treatment. We thus were able to compare the plans with better DDI scores and those actually delivered. When planning target coverage and organs at risk sparing are considered as equally important, the tentative plan with the highest DDI score is shown to coincide with that actually delivered in 32 of the 50 patients considered. In 15 (respectively 3) of the remaining 18 cases, the plan with highest DDI value still coincides with that actually selected, provided that organs at risk sparing is given higher priority (respectively, lower priority) than target coverage. DDI provides a straightforward and non-subjective tool for dosimetric comparison of tentative radiotherapy plans. In particular, DDI readily quantifies differences among competing plans with similar-looking dose-volume histograms and can be easily implemented for any tumor type and localization, irrespective of the planning system and

  8. Production of LiF films for dosimetric thermoluminescence application

    International Nuclear Information System (INIS)

    Mauricio, Claudia Lucia de Pinho

    2000-12-01

    This work studies the LiF monolayer and multilayer polycrystalline film's dosimetric properties. The films were produced by electron beam evaporation technique in aluminium and stainless steel substrates maintained at several temperatures. As dosimetric variable, the intensity of the thermoluminescent (TL) glow curve of the films was used. effects of the substrate type and temperature; of the addition of layers of Mg F 2 NaF and Cu F 2 to the LiF films; and of thermal treatments in the TL response of the produced films were studied. The microstructural characterization of the films was accomplished through measures of scanning electronic microscopy and grazing incidence X-rays diffraction analysis. The dosimetric characterization was made of gamma radiation exposure in a 60 Co source, with kerma from 0,1 to 500 Gy. Studies of reproducibility, homogeneity, stability and other environmental effects were also made. LiF and Cu F 2 : LiF; Mg F 2 films were the only ones that presented mechanical stability and reproducibility of the TL emission. There is a strong indication of some correlation between the residual tension fields inside the films and the intensity of its TL emission peaks. LiF monolayer films present supralinear behaviour from 0,2 to 100 Gy. These films present a main TL glow peak around 150 deg C, whose half-time is about 30 days. Its volumetric sensitivity can reach about 60 times that of LiF powder and about 0,25 that of TLD100 (LiF:Mg, Ti commercial dosimeter from Harshaw Chemical Co.) The homogeneity and reproducibility inside a same film batch is better than 12% for 95% confidence level. Cu F 2 : LiF: Mg F 2 films present linear behaviour from 3 to 500 Gy and its main TL glow peak around 200 deg C did not present any fading for a a period of 30 days, in laboratory conditions. This glow peak is characteristic of the Mg doping of LiF, which confirms the diffusion of Mg ions from the Mg F 2 layer to the LiF layer. The TL volumetric sensitivity of these

  9. The comet assay as a dosimetric tool in evaluation of overexposure localized irradiation; El ensayo de cometa como herramienta de la dosimetria biologica en la evaluacion de sobreexposiciones fuertemente localizadas

    Energy Technology Data Exchange (ETDEWEB)

    Giorgio, Marina Di; Taja, Maria R.; Nasazzi, Nora [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); Bustos, Norma; Cavalieri, Hernan; Bolgiani, Alberto [Fundacion Fortunato Benaim, Buenos Aires (Argentina)

    2001-07-01

    With inhomogeneous exposures, as is characteristic in accidents, the skin may be an important organ in determining clinical prognosis, being dosimetric assessment a necessary requirement. In order to get information to be applied on the evaluation of skin biopsies without culture for an early assessment of irradiation consequences in locally irradiated individuals, contributing with the biophysical techniques, we evaluate the alkaline comet assay (for doses < 5 Gy) as a method for the detection of DNA radiation induced damage in keratinocytes from primary and secondary cultures obtained from medium thickness skin biopsies and epidermal cells, without culture, derived from the same sample of skin biopsies of patients requiring grafts. To extend the dose range (> 5 Gy), neutral comet assay was applied to keratinocytes from primary and secondary cultures and to a suspension of epidermal cells obtained from biopsies irradiated in vitro an afterwards processed to obtain the mentioned cellular suspension, in order to reproduce the closest condition to in vivo overexposure. The correlation of the obtained data with factors of the patient and the corresponding skin graft response, were evaluated. (author)

  10. Some dosimetric properties of the LiF:Mg,Ti evaluated by the automatic 6600 thermoluminescent reader

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shachar, B; Weinstein, M; German, U [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    Some dosimetric properties of the new LiF:Mg,Ti TLD cards were checked, when evaluated by the new automatic 6600 TLD reader. The cards were calibrated to a dose of 1.0 mGy by five identical irradiations, and the TL-dose response was measured for a range of 75 - 1100 mGy. A very high accuracy was found for the three kind of chips measured (TLD-100, TLD-700 and TLD-600) and a low minimum measurable dose (MMD) was found, too. There is a good fit between the analytical evaluation and the theoretical calculation of the MMD. The results obtained are much better than those of the LiF:Mg,Ti cards evaluated by the older automatic 2271 reader used in the last two decades (authors).

  11. Dosimetric Evaluation of Intensity Modulated Radiotherapy and 4-Field 3-D Conformal Radiotherapy in Prostate Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Bora Uysal

    2013-03-01

    Full Text Available Objective: The purpose of this dosimetric study is the targeted dose homogeneity and critical organ dose comparison of 7-field Intensity Modulated Radiotherapy (IMRT and 3-D 4-field conformal radiotherapy. Study Design: Cross sectional study. Material and Methods: Twenty patients with low and moderate risk prostate cancer treated at Gülhane Military Medical School Radiation Oncology Department between January 2009 and December 2009 are included in this study. Two seperate dosimetric plans both for 7-field IMRT and 3D-CRT have been generated for each patient to comparatively evaluate the dosimetric status of both techniques and all the patients received 7-field IMRT. Results: Dose-comparative evaluation of two techniques revealed the superiority of IMRT technique with statistically significantly lower femoral head doses along with reduced critical organ dose-volume parameters of bladder V60 (the volume receiving 60 Gy and rectal V40 (the volume receiving 40 Gy and V60. Conclusion: It can be concluded that IMRT is an effective definitive management tool for prostate cancer with improved critical organ sparing and excellent dose homogenization in target organs of prostate and seminal vesicles.

  12. SU-F-E-06: Dosimetric Characterization of Small Photons Beams of a Novel Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Almonte, A; Polanco, G; Sanchez, E [Instituto Oncologico Dr. Heriberto Pieter, Santo Domingo, Distrito Nacional (Dominican Republic)

    2016-06-15

    Purpose: The aim of the present contribution was to measure the main dosimetric quantities of small fields produced by UNIQUE and evaluate its matching with the corresponding dosimetric data of one 21EX conventional linear accelerator (Varian) in operation at the same center. The second step was to evaluate comparative performance of the EDGE diode detector and the PinPoint micro-ionization chamber for dosimetry of small fields. Methods: UNIQUE is configured with MLC (120 leaves with 0.5 cm leaf width) and a single low photon energy of 6 MV. Beam data were measured with scanning EDGE diode detector (volume of 0.019 mm{sup 3}), a PinPoint micro-ionization chamber (PTW) and for larger fields (≥ 4×4cm{sup 2}) a PTW Semi flex chamber (0.125 cm{sup 3}) was used. The scanning system used was the 3D cylindrical tank manufactured by Sun Nuclear, Inc. The measurement of PDD and profiles were done at 100 cm SSD and 1.5 depth; the relative output factors were measured at 10 cm depth. Results: PDD and the profile data showed less than 1% variation between the two linear accelerators for fields size between 2×2 cm{sup 2} and 5×5cm{sup 2}. Output factor differences was less than 1% for field sizes between 3×3 cm{sup 2} and 10×10 cm{sup 2} and less of 1.5 % for fields of 1.5×1.5 cm{sup 2} and 2×2 cm{sup 2} respectively. The dmax value of the EDGE diode detector, measured from the PDD, was 8.347 mm for 0.5×0,5cm{sup 2} for UNIQUE. The performance of EDGE diode detector was comparable for all measurements in small fields. Conclusion: UNIQUE linear accelerator show similar dosimetrics characteristics as conventional 21EX Varian linear accelerator for small, medium and large field sizes.EDGE detector show good performance by measuring dosimetrics quantities in small fields typically used in IMRT and radiosurgery treatments.

  13. Study of dosimetric quantities and image quality in pediatric examinations of chest and abdomen computed tomography

    International Nuclear Information System (INIS)

    Jornada, Tiago da Silva

    2013-01-01

    This work had the objective to achieve the knowledge of the dosimetric quantities related to chest and abdomen computed tomography (CT) examinations of pediatric patients, in Belo Horizonte city. The reason of this work is based on the fact that the probability of health detriment in children, which it may be caused by radiation, is higher than in adults. Besides, although in many countries the knowledge and control of patient doses is a normal procedure, this safety culture does not exist in Brazil. Another objective of this work was to compare the dosimetric quantity values with the Diagnostic Reference Levels (DRLs); when it was needed, an optimization process was applied and the quality of the diagnostic image obtained with the optimized technical parameters was analyzed. This study was carried out in five hospitals, where the weighted air kerma index (Cw), the volumetric air kerma index (Cvol), the air kerma - length product (PKL,CT), the Effective Dose (E) and the Normalized Effective Dose (En) were determined; three methods were adopted for measurements: the ionization chamber inside a chest pediatric phantom, radiochromic films and the CT-EXPO software. The optimization process was applied to a single hospital through variations in the current (mA) and voltage (kV) of the x-ray tube for the protocols used for abdomen CT examinations. The analysis of the quality of the diagnostic image was done by Normal Distribution and ROC analysis; spatial resolution analysis was used through MTF determination and the noise level was judged in terms quantitative and qualitative. Results of the dosimetric quantities showed that they significantly differed between single-slice and multi-slice tomography units, but their values were always below the recommended DRLs. The optimized values of the dosimetric quantities obtained after the optimization process showed that it was possible to reduce the radiation exposure of pediatric patient without losing the image quality

  14. Dosimetric variation due to CT inter-slice spacing in four-dimensional carbon beam lung therapy

    International Nuclear Information System (INIS)

    Kumagai, Motoki; Mori, Shinichiro; Kandatsu, Susumu; Baba, Masayuki; Sharp, Gregory C; Asakura, Hiroshi; Endo, Masahiro

    2009-01-01

    When CT data with thick slice thickness are used in treatment planning, geometrical uncertainty may induce dosimetric errors. We evaluated carbon ion dose variations due to different CT slice thicknesses using a four-dimensional (4D) carbon ion beam dose calculation, and compared results between ungated and gated respiratory strategies. Seven lung patients were scanned in 4D mode with a 0.5 mm slice thickness using a 256-multi-slice CT scanner. CT images were averaged with various numbers of images to simulate reconstructed images with various slice thicknesses (0.5-5.0 mm). Two scenarios were studied (respiratory-ungated and -gated strategies). Range compensators were designed for each of the CT volumes with coarse inter-slice spacing to cover the internal target volume (ITV), as defined from 4DCT. Carbon ion dose distribution was computed for each resulting ITV on the 0.5 mm slice 4DCT data. The accumulated dose distribution was then calculated using deformable registration for 4D dose assessment. The magnitude of over- and under-dosage was found to be larger with the use of range compensators designed with a coarser inter-slice spacing than those obtained with a 0.5 mm slice thickness. Although no under-dosage was observed within the clinical target volume (CTV) region, D95 remained at over 97% of the prescribed dose for the ungated strategy and 95% for the gated strategy for all slice thicknesses. An inter-slice spacing of less than 3 mm may be able to minimize dose variation between the ungated and gated strategies. Although volumes with increased inter-slice spacing may reduce geometrical accuracy at a certain respiratory phase, this does not significantly affect delivery of the accumulated dose to the target during the treatment course.

  15. On the set up of a thermoluminescent dosimetric system

    International Nuclear Information System (INIS)

    Furetta, C.

    2000-01-01

    In this work are treated the following features: Introduction to the thermoluminescent dosimetric systems, their prerequisites, Initialisation procedure, Batch homogeneity, Procedure for batch homogeneity (IEC), Reference and field dosimeters, Thermal treatments and its general considerations, as well as its initialisation treatment, erasing treatment or standard annealing (also called pre-irradiation annealing), post-irradiation or pre-readout annealing. Also is presented the performance of the annealing study, with its suggested procedures such as: a first and second procedures. Finally, it is showed about experimental data of the annealing treatments and its diagrams. (Author)

  16. Comparison and utilization of two dosimetric systems for e-beam industrial irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fortes, Marcio Z., E-mail: mzamboti@aceletron.com.b [Aceletron Irradiacao Industrial, Rio de Janeiro, RJ (Brazil). Gerencia Tecnica e Operacoes; Sousa, Fernando N.C. de; Boente, Otavio C., E-mail: fernando.nuno@aceletron.com.b, E-mail: otavio@aceletron.com.b [Aceletron Irradiacao Industrial, Rio de Janeiro, RJ (Brazil). Gerencia de Desenvolvimento de Produtos; Sousa, Nuno R.A., E-mail: engenheiro.nuno.sousa@gmail.co [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia Mecanica

    2009-07-01

    The utilization of electron linear accelerators (LINAC's) for industrial irradiation of several products like turf, sterilization of medical products, cosmetics, polymers, food, and gems, can only be successful if a reliable dosimetric system is chosen. There are several different available technologies and two were selected for this study. The first one uses alanine dosimeters which can be read with electron spin resonance spectrometers (ESR); the second uses B3 radiochromic dosimeters which are read with a spectrophotometer. This study presents a comparison of both technologies in the dose range of 1 to 80 kGy, taking into account initial cost, precision, reading time, calibration, among others, for a typical 24 hour production run, and for normal operational routines and tests. It is shown that each system has its own advantages and disadvantages, and that both can be used in an e-beam installation. However, for industrial applications it is necessary to optimize the process, so it is presented which dosimeter is used for each routine application. (author)

  17. Dosimetric properties of dysprosium doped lithium borate glass irradiated by 6 MV photons

    International Nuclear Information System (INIS)

    Ab Rasid, A.; Wagiran, H.; Hashim, S.; Ibrahim, Z.; Ali, H.

    2015-01-01

    Undoped and dysprosium doped lithium borate glass system with empirical formula (70–x) B 2 O 3 –30 Li 2 O–(x) Dy 2 O 3 (x=0.1, 0.3, 0.5, 0.7, 1.0 mol%) were prepared using the melt-quenching technique. The dosimetric measurements were performed by irradiating the samples to 6 MV photon beam using linear accelerator (LINAC) over a dose range of 0.5–5.0 Gy. The glass series of dysprosium doped lithium borate glass produced the best thermoluminescence (TL) glow curve with the highest intensity peak from sample with 1.0 mol% Dy 2 O 3 concentration. Minimum detectable dose was detected at 2.24 mGy, good linearity of regression coefficient, high reproducibility and high sensitivity compared to the undoped glass are from 1.0 mol% dysprosium doped lithium borate glass. The results indicated that the series of dysprosium doped lithium glasses have a great potential to be considered as a thermoluminescence dosimetry (TLD). - Highlights: • TL response of undoped and dysprosium doped lithium borate glass subjected to 6 MV photons irradiation at low dose range. • TL linear response of dysprosium doped lithium borate glass. • The sensitivity of dysprosium doped lithium borate glass is approximately 93 times higher than undoped glass

  18. SU-E-J-169: The Dosimetric and Temporal Effects of Respiratory-Gated Radiation Therapy in Lung Cancer Patients

    International Nuclear Information System (INIS)

    Rouabhi, O; Gross, B; Xia, J; Bayouth, J

    2015-01-01

    Purpose: To evaluate the dosimetric and temporal effects of high dose rate treatment mode for respiratory-gated radiation therapy in lung cancer patients. Methods: Treatment plans from five lung cancer patients (3 nongated (Group 1), 2 gated at 80EX-80IN (Group 2)) were retrospectively evaluated. The maximum tumor motions range from 6–12 mm. Using the same planning criteria, four new treatment plans, corresponding to four gating windows (20EX–20IN, 40EX–40IN, 60EX–60IN, and 80EX–80IN), were generated for each patient. Mean tumor dose (MTD), mean lung dose (MLD), and lung V20 were used to assess the dosimetric effects. A MATLAB algorithm was developed to compute treatment time by considering gantry rotation time, time to position collimator leaves, dose delivery time (scaled relative to the gating window), and communication overhead. Treatment delivery time for each plan was estimated using a 500 MU/min dose rate for the original plans and a 1500 MU/min dose rate for the gated plans. Results: Differences in MTD were less than 1Gy across plans for all five patients. MLD and lung V20 were on average reduced between −16.1% to −6.0% and −20.0% to −7.2%, respectively for non-gated plans when compared with the corresponding gated plans, and between − 5.8% to −4.2% and −7.0% to −5.4%, respectively for plans originally gated at 80EX–80IN when compared with the corresponding 20EX-20IN to 60EX– 60IN gated plans. Treatment delivery times of gated plans using high dose rate were reduced on average between −19.7% (−1.9min) to −27.2% (−2.7min) for originally non-gated plans and −15.6% (−0.9min) to −20.3% (−1.2min) for originally 80EX-80IN gated plans. Conclusion: Respiratory-gated radiation therapy in lung cancer patients can reduce lung toxicity, while maintaining tumor dose. Using a gated high-dose-rate treatment, delivery time comparable to non-gated normal-dose-rate treatment can be achieved. This research is supported by Siemens

  19. On the use of advanced numerical models for the evaluation of dosimetric parameters and the verification of exposure limits at workplaces

    International Nuclear Information System (INIS)

    Catarinucci, L.; Tarricone, L.

    2009-01-01

    With the next transposition of the 2004/40/EC Directive, employers will become responsible for the electromagnetic field level at the workplace. To make this task easier, the scientific community is compiling practical guidelines to be followed. This work aims at enriching such guidelines, especially for the dosimetric issues. More specifically, some critical aspects related to the application of numerical dosimetric techniques for the verification of the safety limit compliance have been highlighted. In particular, three different aspects have been considered: the dosimetric parameter dependence on the shape and the inner characterisation of the exposed subject as well as on the numerical algorithm used, and the correlation between reference limits and basic restriction. Results and discussions demonstrate how, even by using sophisticated numerical techniques, in some cases a complex interpretation of the result is mandatory. (authors)

  20. Analysis of Clinical and Dosimetric Factors Associated With Change in Renal Function in Patients With Gastrointestinal Malignancies After Chemoradiation to the Abdomen

    International Nuclear Information System (INIS)

    May, Kilian Salerno; Khushalani, Nikhil I.; Chandrasekhar, Rameela; Wilding, Gregory E.; Iyer, Renuka V.; Ma, Wen W.; Flaherty, Leayn; Russo, Richard C. C.; Fakih, Marwan; Kuvshinoff, Boris W.; Gibbs, John F.; Javle, Milind M.; Yang, Gary Y.

    2010-01-01

    Purpose: To analyze clinical and dosimetric factors associated with change in renal function in patients with gastrointestinal malignancies after chemoradiation to the abdomen. Methods and Materials: A retrospective review of 164 patients with gastrointestinal malignancies treated between 2002 and 2007 was conducted to evaluate change in renal function after concurrent chemotherapy and three-dimensional conformal abdominal radiotherapy (RT). Laboratory and biochemical endpoints were determined before RT and after RT at 6-month intervals. Factors assessed included smoking, diabetes, hypertension, blood urea nitrogen, creatinine, creatinine clearance (CrCl), chemotherapy, and dose-volume parameters. Renal toxicity was assessed by decrease in CrCl and scored using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring schema. Results: Of 164 patients, 63 had clinical and dosimetric data available. Median follow-up was 17.5 months. Creatinine clearance declined from 98.46 mL/min before RT to 74.20 mL/min one year after chemoradiation (p 10 ), and mean kidney dose were significantly associated with development of Grade ≥2 renal complications at 1 year after chemoradiation (p = 0.0025, 0.0170, and 0.0095, respectively). Conclusions: We observed correlation between pre-RT CrCl, V 10 , and mean kidney dose and decline in CrCl 1 year after chemoradiation. These observations can assist in treatment planning and renal dose constraints in patients receiving chemotherapy and abdominal RT and may help identify patients at increased risk for renal complications.

  1. Analysis of clinical and dosimetric factors associated with change in renal function in patients with gastrointestinal malignancies after chemoradiation to the abdomen.

    Science.gov (United States)

    May, Kilian Salerno; Khushalani, Nikhil I; Chandrasekhar, Rameela; Wilding, Gregory E; Iyer, Renuka V; Ma, Wen W; Flaherty, Leayn; Russo, Richard C; Fakih, Marwan; Kuvshinoff, Boris W; Gibbs, John F; Javle, Milind M; Yang, Gary Y

    2010-03-15

    To analyze clinical and dosimetric factors associated with change in renal function in patients with gastrointestinal malignancies after chemoradiation to the abdomen. A retrospective review of 164 patients with gastrointestinal malignancies treated between 2002 and 2007 was conducted to evaluate change in renal function after concurrent chemotherapy and three-dimensional conformal abdominal radiotherapy (RT). Laboratory and biochemical endpoints were determined before RT and after RT at 6-month intervals. Factors assessed included smoking, diabetes, hypertension, blood urea nitrogen, creatinine, creatinine clearance (CrCl), chemotherapy, and dose-volume parameters. Renal toxicity was assessed by decrease in CrCl and scored using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring schema. Of 164 patients, 63 had clinical and dosimetric data available. Median follow-up was 17.5 months. Creatinine clearance declined from 98.46 mL/min before RT to 74.20 mL/min one year after chemoradiation (p kidney dose were significantly associated with development of Grade > or =2 renal complications at 1 year after chemoradiation (p = 0.0025, 0.0170, and 0.0095, respectively). We observed correlation between pre-RT CrCl, V(10), and mean kidney dose and decline in CrCl 1 year after chemoradiation. These observations can assist in treatment planning and renal dose constraints in patients receiving chemotherapy and abdominal RT and may help identify patients at increased risk for renal complications. Published by Elsevier Inc.

  2. The choice of statistical methods for comparisons of dosimetric data in radiotherapy.

    Science.gov (United States)

    Chaikh, Abdulhamid; Giraud, Jean-Yves; Perrin, Emmanuel; Bresciani, Jean-Pierre; Balosso, Jacques

    2014-09-18

    Novel irradiation techniques are continuously introduced in radiotherapy to optimize the accuracy, the security and the clinical outcome of treatments. These changes could raise the question of discontinuity in dosimetric presentation and the subsequent need for practice adjustments in case of significant modifications. This study proposes a comprehensive approach to compare different techniques and tests whether their respective dose calculation algorithms give rise to statistically significant differences in the treatment doses for the patient. Statistical investigation principles are presented in the framework of a clinical example based on 62 fields of radiotherapy for lung cancer. The delivered doses in monitor units were calculated using three different dose calculation methods: the reference method accounts the dose without tissues density corrections using Pencil Beam Convolution (PBC) algorithm, whereas new methods calculate the dose with tissues density correction for 1D and 3D using Modified Batho (MB) method and Equivalent Tissue air ratio (ETAR) method, respectively. The normality of the data and the homogeneity of variance between groups were tested using Shapiro-Wilks and Levene test, respectively, then non-parametric statistical tests were performed. Specifically, the dose means estimated by the different calculation methods were compared using Friedman's test and Wilcoxon signed-rank test. In addition, the correlation between the doses calculated by the three methods was assessed using Spearman's rank and Kendall's rank tests. The Friedman's test showed a significant effect on the calculation method for the delivered dose of lung cancer patients (p Wilcoxon signed-rank test of paired comparisons indicated that the delivered dose was significantly reduced using density-corrected methods as compared to the reference method. Spearman's and Kendall's rank tests indicated a positive correlation between the doses calculated with the different methods

  3. Dosimetric performance of the new high-definition multileaf collimator for intracranial stereotactic radiosurgery.

    Science.gov (United States)

    Dhabaan, Anees; Elder, Eric; Schreibmann, Eduard; Crocker, Ian; Curran, Walter J; Oyesiku, Nelson M; Shu, Hui-Kuo; Fox, Tim

    2010-06-21

    The objective was to evaluate the performance of a high-definition multileaf collimator (MLC) of 2.5 mm leaf width (MLC2.5) and compare to standard 5 mm leaf width MLC (MLC5) for the treatment of intracranial lesions using dynamic conformal arcs (DCA) technique with a dedicated radiosurgery linear accelerator. Simulated cases of spherical targets were created to study solely the effect of target volume size on the performance of the two MLC systems independent of target shape complexity. In addition, 43 patients previously treated for intracranial lesions in our institution were retrospectively planned using DCA technique with MLC2.5 and MLC5 systems. The gross tumor volume ranged from 0.07 to 40.57 cm3 with an average volume of 5.9 cm3. All treatment parameters were kept the same for both MLC-based plans. The plan evaluation was performed using figures of merits (FOM) for a rapid and objective assessment on the quality of the two treatment plans for MLC2.5 and MLC5. The prescription isodose surface was selected as the greatest isodose surface covering >or= 95% of the target volume and delivering 95% of the prescription dose to 99% of target volume. A Conformity Index (CI) and conformity distance index (CDI) were used to quantifying the dose conformity to a target volume. To assess normal tissue sparing, a normal tissue difference (NTD) was defined as the difference between the volume of normal tissue receiving a certain dose utilizing MLC5 and the volume receiving the same dose using MLC2.5. The CI and normal tissue sparing for the simulated spherical targets were better with the MLC2.5 as compared to MLC5. For the clinical patients, the CI and CDI results indicated that the MLC2.5 provides better treatment conformity than MLC5 even at large target volumes. The CI's range was 1.15 to 2.44 with a median of 1.59 for MLC2.5 compared to 1.60-2.85 with a median of 1.71 for MLC5. Improved normal tissue sparing was also observed for MLC2.5 over MLC5, with the NTD always

  4. Dosimetric and Clinical Outcomes With Intensity Modulated Radiation Therapy After Chemotherapy for Patients With Early-Stage Diffuse Large B-cell Lymphoma of Waldeyer Ring

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yong-Gang; Qi, Shu-Nan; Wang, Shu-Lian; Liu, Yue-Ping; Wang, Wei-Hu; Jin, Jing; Song, Yong-Wen; Ren, Hua; Fang, Hui [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); He, Xiao-Hui; Dong, Mei [Department of Medical Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Chen, Bo; Lu, Ning-Ning; Li, Ning; Tang, Yuan; Tang, Yu; Dai, Jian-Rong [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Li, Ye-Xiong, E-mail: yexiong12@163.com [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China)

    2016-10-01

    Purpose: To assess the dosimetric benefit, prognosis, and toxicity of intensity modulated radiation therapy (IMRT) for early-stage, diffuse large B-cell lymphoma of Waldeyer ring (WR-DLBCL). Methods and Materials: Sixty-one patients with early-stage WR-DLBCL who received chemotherapy followed by IMRT were retrospectively reviewed. Dosimetric parameters for the target volume and critical normal structures were evaluated, and survival was calculated. Linear regression analysis was used to assess the effect of the mean dose (D{sub mean}) to the parotid glands on xerostomia. Results: The median conformity index and homogeneity index of the planning target volume (PTV) were 0.83 and 0.90, respectively, demonstrating very good coverage of the target volume. The mean dose to the parotid glands was 24.9 Gy. The 5-year overall survival (OS), progression-free survival (PFS), and locoregional control (LRC) were 94.7%, 93.1%, and 98.3%, respectively. Early and late toxicities were mild, and no patient experienced late grade ≥3 toxicities. The D{sub mean} to the parotid glands had a linear correlation with late grade ≥2 xerostomia. Conclusions: IMRT after chemotherapy can provide excellent dose conformity and achieve favorable survival and LRC with mild toxicities in patients with early-stage WR-DLBCL. Dose constraints for the parotid glands should be limited to <24 Gy for early-stage WR-DLBCL.

  5. Understanding the dosimetric powder EPR spectrum of sucrose by identification of the stable radiation-induced radicals

    International Nuclear Information System (INIS)

    Vrielinck, H.; Vanhaelewyn, G.; Matthys, P.; Callens, F.; Kusakovskij, J.

    2014-01-01

    Sucrose, the main component of table sugar, present in nearly every household and quite radiation sensitive, is considered as an interesting emergency dosemeter. Another application of radiation-induced radicals in sugars is the detection of irradiation in sugar-containing foodstuffs. The complexity of electron paramagnetic resonance (EPR) spectra of radicals in these materials, as a result of many hyperfine interactions and the multi-compositeness of the spectra of individual sugars, complicate dose assessment and the improvement of protocols for control and identification of irradiated sugar-containing foodstuffs using EPR. A thorough understanding of the EPR spectrum of individual irradiated sugars is desirable when one wants to reliably use them in a wide variety of dosimetric applications. Recently, the dominant room temperature stable radicals in irradiated sucrose have been thoroughly characterised using EPR, electron nuclear double resonance (ENDOR) and ENDOR-induced EPR. These radicals were structurally identified by comparing their proton hyperfine and g-tensors with the results of Density Functional Theory calculations for test radical structures. In this paper, the authors use the spin Hamiltonian parameters determined in these studies to simulate powder EPR spectra at the standard X-band (9.5 GHz), commonly used in applications, and at higher frequencies, up to J-band (285 GHz), rendering spectra with higher resolution. A few pitfalls in the simulation process are highlighted. The results indicate that the major part of the dosimetric spectrum can be understood in terms of three dominant radicals, but as-yet unidentified radicals also contribute in a non-negligible way. (authors)

  6. Assessment of tidal range energy resources based on flux conservation in Jiantiao Bay, China

    Science.gov (United States)

    Du, Min; Wu, He; Yu, Huaming; Lv, Ting; Li, Jiangyu; Yu, Yujun

    2017-12-01

    La Rance Tidal Range Power Station in France and Jiangxia Tidal Range Power Station in China have been both long-term successful commercialized operations as kind of role models for public at large for more than 40 years. The Sihwa Lake Tidal Range Power Station in South Korea has also developed to be the largest marine renewable power station with its installed capacity 254 MW since 2010. These practical applications prove that the tidal range energy as one kind of marine renewable energy exploitation and utilization technology is becoming more and more mature and it is used more and more widely. However, the assessment of the tidal range energy resources is not well developed nowadays. This paper summarizes the main problems in tidal range power resource assessment, gives a brief introduction to tidal potential energy theory, and then we present an analyzed and estimated method based on the tide numerical modeling. The technical characteristics and applicability of these two approaches are compared with each other. Furthermore, based on the theory of tidal range energy generation combined with flux conservation, this paper proposes a new assessment method that include a series of evaluation parameters and it can be easily operated to calculate the tidal range energy of the sea. Finally, this method is applied on assessment of the tidal range power energy of the Jiantiao Harbor in Zhejiang Province, China for demonstration and examination.

  7. Safety assessment of indoor live fire range, May 1989

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the indoor live fire range (LFR) at EG&G Mound Applied Technology plant. The purpose of the indoor LFR is to conduct training with live ammunition for all designated personnel. The SA examines the risks that are attendant to the operation of an indoor LFR for this purpose.

  8. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products; Sistemas dosimetricos de altas dosis, tasa de dosis y uniformidad de dosis en alimentos y producto medico

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, J.; Vivanco, M.; Castro, E., E-mail: jvargas@ipen.gob.pe [Instituto Peruano de Energia Nuclear, Av. Canada 1470, San Borja, Lima (Peru)

    2014-08-15

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  9. Dosimetric characteristics of muscovite mineral studied under different annealing conditions

    International Nuclear Information System (INIS)

    Kalita, J M; Wary, G

    2015-01-01

    The annealing effect on the thermoluminescence (TL) characteristics of x-ray irradiated muscovite mineral relevant to dosimetry has been studied. For un-annealed and 473 K annealed samples an isolated TL peak has been observed at around 347 K; however, annealing at 573, 673 and 773 K two composite peaks have been recorded at around 347 and 408 K. Kinetic analysis reveals that there is a trap level at a depth of 0.71 eV, and due to annealing at 573 K (or above), a new trap level generates at 1.23 eV. The dosimetric characteristics, such as dose response, fading and reproducibility, have been studied in detail for all types of samples. The highest linear dose response has been observed from 10 to 2000 mGy in the 773 K annealed sample. Due to generation of the deep trap level, fading is found to reduce significantly just after annealing above 573 K. Reproducibility analysis shows that after 10 cycles of reuse the coefficient of variations in the results for 60, 180 and 1000 mGy dose irradiated 773 K annealed samples are found to be 1.78%, 1.37% and 1.58%, respectively. These analyses demand that after proper annealing muscovite shows important dosimetric features that are essentially required for a thermoluminescence dosimeter (TLD). (paper)

  10. 6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator

    International Nuclear Information System (INIS)

    Tacke, Martin B.; Nill, Simeon; Haering, Peter; Oelfke, Uwe

    2008-01-01

    New technical developments constantly aim at improving the outcome of radiation therapy. With the use of a computer-controlled multileaf collimator (MLC), the quality of the treatment and the efficiency in patient throughput is significantly increased. New MLC designs aim to further enhance the advantages. In this article, we present the first detailed experimental investigation of the new 160 MLC TM , Siemens Medical Solutions. The assessment included the experimental investigation of typical MLC characteristics such as leakage, tongue-and-groove effect, penumbra, leaf speed, and leaf positioning accuracy with a 6 MV treatment beam. The leakage is remarkably low with an average of 0.37% due to a new design principle of slightly tilted leaves instead of the common tongue-and-groove design. But due to the tilt, the triangular tongue-and-groove effect occurs. Its magnitude of approximately 19% is similar to the dose defect measured for MLCs with the common tongue-and-groove design. The average longitudinal penumbra measured at depth d max =15 mm with standard 100x100 mm 2 fields is 4.1±0.5 mm for the central range and increases to 4.9±1.3 mm for the entire field range of 400x400 mm 2 . The increase is partly due to the single-focusing design and the large distance between the MLC and the isocenter enabling a large patient clearance. Regarding the leaf speed, different velocity tests were performed. The positions of the moving leaves were continuously recorded with the kilovoltage-imaging panel. The maximum leaf velocities measured were 42.9±0.6 mm/s. In addition, several typical intensity-modulated radiation therapy treatments were performed and the delivery times compared to the Siemens OPTIFOCUS MLC. An average decrease of 11% in delivery time was observed. The experimental results presented in this article indicate that the dosimetric characteristics of the 160 MLC are capable of improving the quality of dose delivery with respect to precision and dose

  11. A design of ambient dose equivalent dosimeter and its dosimetric performance

    International Nuclear Information System (INIS)

    Zhao Shian; Ou Xiangming; Li Kaibao

    1997-01-01

    Objective: To design an ambient dose equivalent dosimeter with digital display for radiation protection, which is based on the definition of the new operational radiation quantity for environmental monitoring-ambient dose equivalent recommended by the International Commission on Radiation Units and Measurements (ICRU) Report 39. Methods: Considering the energy response of the instrument, the inner wall of ionizing chamber is coated with gum graphite added with a bit of metal powder. Results: Using this chamber, measurement of H * (10) for photon radiation with unknown spectrum distribution is possible in the energy range from 47 keV to 230 keV with an uncertainty of better than 5%. The configuration, technology and dosimetric performance of the chamber and automatic functions of the reader are presented. Conclusion: The ambient dose equivalent dosimeter can be used as not only a working reference dosimeter, but also a field dosimeter for radiation protection because the readings are expressed directly in ambient dose equivalent and averaged automatically in the period of measurement. Also, its power is supplied by battery for the portable purpose and the readings are displayed on the screen with light-background for dim field

  12. Development and application of a dosimetric methodology of therapeutic X radiation beams using a tandem system

    International Nuclear Information System (INIS)

    Sartoris, Carla Eri

    2001-01-01

    In radiotherapy the use of orthovoltage X radiation beams is still recommended; to obtain satisfactory results, a periodic control is necessary to check the performance of the ionization chambers and the radiation beams characteristics. This control is performed by using standard dosimetric procedures, as for example the determination of half-value layers and the absorbed dose rates. A Tandem system was established in this work using a pair of ionization chambers (a thimble type and a superficial type) used for measures in a medical institution, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The results obtained show the application of this method in dosimetric procedures of orthovoltage beams (radiotherapy) as a complement for a quality control program. (author)

  13. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    International Nuclear Information System (INIS)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-01-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  14. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy.

    Science.gov (United States)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-02-01

    To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Practical realisation of individual dosimetric control of internal and external irradiation during works at 'Ukrytie' shelter

    International Nuclear Information System (INIS)

    Likhtarev, I.A.; Bondarenko, O.S.; Berkovskij, V.B.; Chumak, V.K.; Korneev, A.A.; Dmitrienko, A.V.

    1999-01-01

    Individual dosimetric control requires the minimisation of personnel irradiation doses and needs forecasting and planning of dose loads. System of individual dose control and its functions at 'Ukrytie' shelter are described

  16. Correlation of administered activity and dosimetric data in patients treated with 131MIBG therapy

    International Nuclear Information System (INIS)

    Castellani, M.; Chiesa, C.; Aliberti, G.; Maccauro, M.; Seregni, E.; Lorenzoni, A.; Luksch, R.

    2015-01-01

    Full text of publication follows. Aims: the purpose of the study was to optimized 131-MIBG (or 131 I-MIBG) therapy in children and adults patients with neural crest tumors, by correlating the administered pro/KXg activity to whole-body dosimetry and hematologic toxicity. Materials and methods: from September 2003, to June 2012 twenty-four patients (9 children, 15 adults) (13 neuroblastoma, 9 pheochromocytoma/paraganglioma, 2 medullary thyroid carcinoma) treated with 131 I-MIBG were enrolled in the study. In each patient dosimetric estimation was carried out with MIRD method after patient therapy, using imaging acquisition or probe determination (from 1 to 168 hours). Hematological toxicity was evaluated according to WHO grade by weekly blood count for at least 6 weeks or until recovery. Whole Body Dose (WBD) was correlated with administered pro/KXg activity and bone marrow toxicity. Results: a total of forty-five dosimetric studies have been performed, 16/45 in children and 29/45 in adult patients. Administered activity ranged from 7.4 to 16.65 GBq, corresponding in children to 5-21 mCi/KXg (median 10 mCi/KXg) and in adults to 3-7 mCi/KXg. (median 5 mCi/KXg). In 4 patients (3 children, 1 adult) 2 weeks after 131 I-MING therapy autologous stem cell transplantations were performed. Grade II-III hematological toxicity was observed in all children and in 6/15 adult patient. Whole Body Dose ranged from 1 Gy to 3.6 Gy (median 1.7 Gy) in children, meanwhile it ranged between 0.55 and 1.87 Gy (median 0.96 Gy) in adults. In 5/16 children studies WBD was about 2 Gy and one child received a dose of 3.6 Gy (0.4 Gy/GBq), corresponding to an activity of 18 mCi/KXg. Conclusion: contrary to published data in children the pro/KXg activity is not a good predictor of WBD. In these cases WBD calculation can be affected by the presence of large tumor masses which overestimates the absorbed dose. In any case the administration of activity superior to 15 mCi/KXg is known to be associated

  17. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    Energy Technology Data Exchange (ETDEWEB)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D [OH State University, Columbus, OH (United States)

    2015-06-15

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.

  18. SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

    International Nuclear Information System (INIS)

    Lu, L; Allan, E; Putten, M Van; Gupta, N; Blakaj, D

    2015-01-01

    Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis

  19. SU-F-T-431: Dosimetric Validation of Acuros XB Algorithm for Photon Dose Calculation in Water

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, L [Rajiv Gandhi Cancer Institute & Research Center, New Delhi, Delhi (India); Yadav, G; Kishore, V [Bundelkhand Institute of Engineering & Technology, Jhansi, Uttar pradesh (India); Bhushan, M; Samuvel, K; Suhail, M [Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, Delhi (India)

    2016-06-15

    Purpose: To validate the Acuros XB algorithm implemented in Eclipse Treatment planning system version 11 (Varian Medical System, Inc., Palo Alto, CA, USA) for photon dose calculation. Methods: Acuros XB is a Linear Boltzmann transport equation (LBTE) solver that solves LBTE equation explicitly and gives result equivalent to Monte Carlo. 6MV photon beam from Varian Clinac-iX (2300CD) was used for dosimetric validation of Acuros XB. Percentage depth dose (PDD) and profiles (at dmax, 5, 10, 20 and 30 cm) measurements were performed in water for field size ranging from 2×2,4×4, 6×6, 10×10, 20×20, 30×30 and 40×40 cm{sup 2}. Acuros XB results were compared against measurements and anisotropic analytical algorithm (AAA) algorithm. Results: Acuros XB result shows good agreement with measurements, and were comparable to AAA algorithm. Result for PDD and profiles shows less than one percent difference from measurements, and from calculated PDD and profiles by AAA algorithm for all field size. TPS calculated Gamma error histogram values, average gamma errors in PDD curves before dmax and after dmax were 0.28, 0.15 for Acuros XB and 0.24, 0.17 for AAA respectively, average gamma error in profile curves in central region, penumbra region and outside field region were 0.17, 0.21, 0.42 for Acuros XB and 0.10, 0.22, 0.35 for AAA respectively. Conclusion: The dosimetric validation of Acuros XB algorithms in water medium was satisfactory. Acuros XB algorithm has potential to perform photon dose calculation with high accuracy, which is more desirable for modern radiotherapy environment.

  20. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters.

    Science.gov (United States)

    Xu, Huijun; Gordon, J James; Siebers, Jeffrey V

    2011-02-01

    A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The

  1. Implementation of a gel dosimeter for dosimetric verification of treatments with RapidArcTM

    International Nuclear Information System (INIS)

    Cortes, H.; Vasquez, J.; Plazas, M.

    2014-08-01

    The gel dosimetry represents advantages on other dosimetric systems for its potential of analyzing information in third dimension (3D). This work seeks to find another alternative for the verification of treatments of high complexity like the RapidArc TM . A gel type Magic was prepared and characterized, which was irradiated with base in a plan of RapidArc TM calculated in the Treatment Planning System (Tps) Eclipse, using the Anisotropic Analytic Algorithm (Aaa) for a beam with an acceleration potential of 6 MV. The dosimeter was characterized using Magnetic Resonance Images starting from the correlation between the T2 and the dose. The dose distribution curves were analyzed in second dimension (2D) using the program Omni Pro-I mrT and were compared with the curves obtained for the Tps under the approach gamma 2D. The comparison showed that the Gel represents a valid option inside the acceptable ranges for Quality Assurance in radiotherapy. (Author)

  2. Dosimetric characteristics of the Best registered double-wall 103Pd brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, A.S.; Bharucha, Z.; Yoe-Sein, M.; Sowards, Keith

    2001-01-01

    103 Pd and 125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, a double-wall 103 Pd source has been introduced, which has a design different from that of sources presently on the market. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined following the AAPM Task Group 43 recommendations and were related to the October 10, 2000 revision of the NIST 1999 S K Standard for 103 Pd. Measurements were performed in a Solid Water trade mark sign phantom using LiF thermoluminescent dosimeters. For these measurements, slabs of Solid Water trade mark sign phantom material were machined to accommodate the source and LiF TLD chips of dimensions (3.1x3.1x0.8 mm 3 ) and (1.0x1.0x1.0 mm 3 ). The TLD chips were surrounded by at least 10 cm of Solid Water trade mark sign phantom material to provide full scattering conditions. The Monte Carlo simulations were performed in Solid Water trade mark sign and liquid water using the PTRAN code. The results of this investigation show an excellent agreement (within 5%) between the measured (0.67±8% cGy h -1 U -1 ) and calculated (to be 0.65±3% cGy h -1 U -1 ) dose rate constant in Solid Water trade mark sign . The Monte Carlo calculated dose rate constant of the Best registered 103 Pd in water was found to be 0.67±0.02 cGy h -1 U -1 . The radial dose function, g(r), of the new 103 Pd source was measured at distances ranging from 0.5 and 7 cm using LiF TLD in Solid Water trade mark sign phantom material. Moreover, the radial dose function of the new source was calculated in liquid water and Solid Water trade mark sign at distances ranging from 0.1 to 7 cm using the PTRAN Monte Carlo Code. The anisotropy function, F(r,θ), of the new 103 Pd source was also measured in Solid Water trade mark sign and calculated in both Solid Water trade mark sign and water phantom material

  3. EchoSeed Model 6733 Iodine-125 brachytherapy source: Improved dosimetric characterization using the MCNP5 Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Mosleh-Shirazi, M. A.; Hadad, K.; Faghihi, R.; Baradaran-Ghahfarokhi, M.; Naghshnezhad, Z.; Meigooni, A. S. [Center for Research in Medical Physics and Biomedical Engineering and Physics Unit, Radiotherapy Department, Shiraz University of Medical Sciences, Shiraz 71936-13311 (Iran, Islamic Republic of); Radiation Research Center and Medical Radiation Department, School of Engineering, Shiraz University, Shiraz 71936-13311 (Iran, Islamic Republic of); Comprehensive Cancer Center of Nevada, Las Vegas, Nevada 89169 (United States)

    2012-08-15

    This study primarily aimed to obtain the dosimetric characteristics of the Model 6733 {sup 125}I seed (EchoSeed) with improved precision and accuracy using a more up-to-date Monte-Carlo code and data (MCNP5) compared to previously published results, including an uncertainty analysis. Its secondary aim was to compare the results obtained using the MCNP5, MCNP4c2, and PTRAN codes for simulation of this low-energy photon-emitting source. The EchoSeed geometry and chemical compositions together with a published {sup 125}I spectrum were used to perform dosimetric characterization of this source as per the updated AAPM TG-43 protocol. These simulations were performed in liquid water material in order to obtain the clinically applicable dosimetric parameters for this source model. Dose rate constants in liquid water, derived from MCNP4c2 and MCNP5 simulations, were found to be 0.993 cGyh{sup -1} U{sup -1} ({+-}1.73%) and 0.965 cGyh{sup -1} U{sup -1} ({+-}1.68%), respectively. Overall, the MCNP5 derived radial dose and 2D anisotropy functions results were generally closer to the measured data (within {+-}4%) than MCNP4c and the published data for PTRAN code (Version 7.43), while the opposite was seen for dose rate constant. The generally improved MCNP5 Monte Carlo simulation may be attributed to a more recent and accurate cross-section library. However, some of the data points in the results obtained from the above-mentioned Monte Carlo codes showed no statistically significant differences. Derived dosimetric characteristics in liquid water are provided for clinical applications of this source model.

  4. Harmonisation and dosimetric quality assurance in individual monitoring for external radiation

    DEFF Research Database (Denmark)

    Bartlett, D.T.; Ambrosi, P.; Back, C.

    2001-01-01

    The current situation amongst Member States is that there are widely differing national requirements for dosimetric services and for dosemeter performance. It is clear that with the free movement of workers within the European Union (EU) and the requirements for individual dosimetry given...... of individual monitoring using personal dosemeters and assisting movement towards harmonised procedures. An outline of the work of the action group is given and the term 'harmonisation' is discussed....

  5. Present status of the dosimetric control of food irradiation in France

    International Nuclear Information System (INIS)

    Laizier, J.; Mosse, D.

    1986-01-01

    The irradiation of food arises much interest in France, although the process is still industrially used to a very limited extend, but every facts indicate a strong trend to the development of the uses. This arises new problems of dosimetric control. The efforts of the few last years to overcome those problems were focused along two axis: the development of a code of good practice and that of using more widely the alanine dosimeter

  6. Historical revision of the exposure magnitude and the dosimetric magnitudes used in radiological protection

    International Nuclear Information System (INIS)

    Gonzalez J, F.; Alvarez R, J. T.

    2014-10-01

    In this work a historical revision of the exposure magnitude development and their roentgen unit (1905 - 2011) is made, noting that it had their origin in the electric methods for the detection of the ionizing radiation in the period of 1895 at 1937. However, the ionization is not who better characterizes the physical, chemical and biological effects of the ionizing radiations, but is the energy deposited by this radiation in the interest bodies, which led historically to the development of dosimetric magnitudes in energy terms like they are: the absorbed dose D (1950), the kerma K (1958) and the equivalent dose H (1962). These dosimetric magnitudes culminated with the definition of the effective equivalent dose or effective dose which is not measurable and should be considered with the operative magnitudes ICRU: H environmental equivalent dose and/or H directional equivalent dose, which can be determined by means of a conversion coefficient that is applied to the exposure, kerma in air, fluence, etc. (Author)

  7. Dosimetric Effect of Online Image-Guided Anatomical Interventions for Postprostatectomy Cancer Patients

    International Nuclear Information System (INIS)

    Diot, Quentin; Olsen, Christine; Kavanagh, Brian; Raben, David; Miften, Moyed

    2011-01-01

    Purpose: To assess daily variations in delivered doses in postprostatectomy patients, using kilovoltage cone-beam CT (CBCT) datasets acquired before and after interventions to correct for observed distortions in volume/shape of rectum and bladder. Methods and Materials: Seventeen consecutive patients treated with intensity-modulated radiotherapy to the prostate bed were studied. For patients with large anatomical variations, quantified by either a rectal wall displacement of >5 mm or bladder volume change of >50% on the CBCT compared with the planning CT, an intervention was performed to adjust the rectum and/or bladder filling. Cumulative doses over the pre- and post-intervention fractions were calculated by tracking the position of the planning CT voxels on different CBCTs using a deformable surface-mapping algorithm. Dose and displacements vectors were projected on two-dimensional maps, the minimal dose received by the highest 95% of the planing target volume (PTV D95) and the highest 10% of the rectum volume (D10) as well as the bladder volume receiving >2 Gy (V2) were evaluated. Results: Of 544 fractions, 96 required intervention. Median (range) number of interventions per patient was 5 (2-12). Compared with the planning values, the mean (SD) pre- vs. postintervention value for PTV D95 was -2% (2%) vs. -1% (2%) (p < 0.12), for rectum D10 was -1% (4%) vs. +1% (4%) (p < 0.24), and for bladder V2 was +6% vs. +20% (p < 0.84). Conclusions: Interventions to reduce treatment volume deformations due to bladder and rectum fillings are not necessary when patients receive daily accurate CBCT localization, and the frequency of those potential interventions is low. However, for hypofractionated treatments, the relative frequency can significantly increase, and interventions can become more dosimetrically beneficial.

  8. Dosimetric advantage and clinical implication of a micro-multileaf collimator in the treatment of prostate with intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Wang Lu; Hoban, Peter; Paskalev, Kamen; Yang Jie; Li Jinsheng; Chen Lili; Xiong Weijun; Ma, Charlie

    2005-01-01

    This paper investigates the dosimetric benefits of a micro-multileaf (4-mm leaf width) collimator (mMLC) for intensity-modulated radiation therapy (IMRT) treatment planning of the prostate cancer and its potential application for dose escalation and hypofractionation. We compared treatment plans for IMRT delivery using 2 different multileaf collimator (MLC) leaf widths (4 vs. 10 mm) for 10 patients with prostate cancer. Treatment planning was performed on the XknifeRT2 treatment planning system. All beams and optimization parameters were identical for the mMLC and MLC plans. All of the plans were normalized to ensure that 95% of the planning target volume (PTV) received 100% of the prescribed dose (74 Gy). The differences in dose distribution between the 2 groups of plans using the mMLC and the MLC were assessed by dose-volume histogram (DVH) analysis of the target and critical organs. Significant reductions in the volume of rectum receiving medium to higher doses were achieved using the mMLC. The average decrease in the volume of the rectum receiving 40, 50, and 60 Gy using the mMLC plans was 40.2%, 33.4%, and 17.7%, respectively, with p-values less than 0.0001 for V 40 and V 50 and 0.012 for V 60 . The mean dose reductions for D 17 and D 35 for the rectum were 20.0% (p 0.78). Because of the reduction of rectal volume receiving medium to higher doses, dose to the prostate target can be escalated by about 20 Gy to over 74 Gy, while keeping the rectal dose (either denoted by D 17 or D 35 ) the same as those with the use of the MLC. The maximum achievable dose, derived when the rectum is allowed to reach the tolerance level, was found to be in the range of 113-172 Gy (using the tolerance value of D 17 ). We conclude that the use of the mMLC for IMRT of the prostate may facilitate dose hypofractionation due to its dosimetric advantage in significantly improving the DVH parameters of the prostate and critical organs. When used for conventional fractionation scheme, m

  9. Beam standardization and dosimetric methodology in computed tomography

    International Nuclear Information System (INIS)

    Maia, Ana Figueiredo

    2005-01-01

    Special ionization chambers, named pencil ionization chambers, are used in dosimetric procedures in computed tomography beams (CT). In this work, an extensive study about pencil ionization chambers was performed, as a contribution to the accuracy of the dosimetric procedures in CT beams. The international scientific community has recently been discussing the need of the establishment of a specific calibration procedure for CT ionization chambers, once these chambers present special characteristics that differentiate them from other ionization chambers used in diagnostic radiology beams. In this work, an adequate calibration procedure for pencil ionization chambers was established at the Calibration Laboratory, of the Institute de Pesquisas Energeticas e Nucleares, in accordance with the most recent international recommendations. Two calibration methodologies were tested and analyzed by comparative studies. Moreover, a new extended length parallel plate ionization chamber, with a transversal section very similar to pencil ionization chambers, was developed. The operational characteristics of this chamber were determined and the results obtained showed that its behaviour is adequate as a reference system in CT standard beams. Two other studies were performed during this work, both using CT ionization chambers. The first study was about the performance of a pencil ionization chamber in standard radiation beams of several types and energies, and the results showed that this chamber presents satisfactory behaviour in other radiation qualities as of diagnostic radiology, mammography and radiotherapy. In the second study, a tandem system for verification of hal'-value layer variations in CT equipment, using a pencil ionization chamber, was developed. Because of the X rays tube rotation, the determination of half-value layers in computed tomography equipment is not an easy task, and it is usually not performed within quality control programs. (author)

  10. The pitfalls of dosimetric commissioning for intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Tohyama, Naoki; Kodama, Takashi; Hatano, K.

    2013-01-01

    Intensity modulated radiation therapy (IMRT) allows higher radiation dose to be focused to the target volumes while minimizing the dose to OAR. To start of clinical treatment in IMRTvwe must perform commissioning strictly than 3D-conformal radiotherapy (CRT). In this report, pitfalls of dosimetric commissioning for intensity modulated radiation therapy were reviewed. Multileaf collimator (MLC) offsets and MLC transmissions are important parameters in commissioning of RTPS for IMRT. Correction of depth scaling and fluence scaling is necessary for dose measurement using solid phantom. (author)

  11. Mevatron-74 10MeV photon beam: a study of dosimetric quantities

    International Nuclear Information System (INIS)

    Souza, C.N. de

    1986-01-01

    The Mevatron-74 linear accelerator dosimetric quantities were studied. In water and polystyrene measurements with an ionization chamber were done for following physical parameters: maximum dose depth and surface dose, field size dependence, central axis percentage depth dose, beam flatness and simmetry, and also verification the inverse square law for the distances normally used in therapy. Isodose curves were generated by the decrement lines method. (Author) [pt

  12. Dosimetric predictors of radiation-induced pericardial effusion in esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Ichiro; Watanabe, Shigenobu [Yokohama City University Medical Center, Department of Radiation Oncology, Minami-ku, Yokohama, Kanagawa-prefecture (Japan); Sakamaki, Kentaro [Yokohama City University, Department of Biostatistics, Yokohama City University, Yokohama (Japan); Ogino, Yuka [Tokyo Institute of Technology, Department of Systems and Control Engineering, Tokyo (Japan); Kunisaki, Chikara [Yokohama City University Medical Center, Department of Surgery, Gastroenterological Center, Yokohama (Japan); Kimura, Kazuo [Yokohama City University Medical Center, Division of Cardiology, Yokohama (Japan)

    2017-07-15

    To evaluate the dose-volume parameters of the pericardium and heart in order to reduce the risk of radiation-induced pericardial effusion (PE) and symptomatic PE (SPE) in esophageal cancer patients treated with concurrent chemoradiotherapy. In 86 of 303 esophageal cancer patients, follow-up CT was obtained at least 24 months after concurrent chemoradiotherapy. Correlations between clinical factors, including risk factors for cardiac disease, dosimetric factors, and the incidence of PE and SPE after radiotherapy were analyzed using Cox proportional hazard regression analysis. Significant dosimetric factors with the highest hazard ratios were investigated using zones separated according to their distance from esophagus. PE developed in 49 patients. Univariate analysis showed the mean heart dose, heart V{sub 5}-V{sub 55}, mean pericardium dose, and pericardium V{sub 5}-V{sub 50} to all significantly affect the incidence of PE. Additionally, body surface area was correlated with the incidence of PE in multivariate analysis. Grade 3 and 4 SPE developed in 5 patients. The pericardium V{sub 50} and pericardium D{sub 10} significantly affected the incidence of SPE. The pericardium V{sub 50} in patients with SPE ranged from 17.1 to 21.7%. Factors affecting the incidence of SPE were the V{sub 50} of the pericardium zones within 3 cm and 4 cm of the esophagus. A wide range of radiation doses to the heart and pericardium were related to the incidence of PE. A pericardium V{sub 50} ≤ 17% is important to avoid symptomatic PE in esophageal cancer patients treated with concurrent chemoradiotherapy. (orig.) [German] Beurteilung der Dosis-Volumen-Parameter fuer Perikard und Herz zur Risikoreduzierung eines strahleninduzierten Perikardergusses (PE) und eines symptomatischen PE (SPE) bei mit kombinierter Strahlenchemotherapie behandelten Speiseroehrenkrebspatienten. Bei 86 von 303 Speiseroehrenkrebspatienten wurde mindestens 24 Monate nach der Strahlenchemotherapie ein Kontroll

  13. SU-E-J-110: Dosimetric Analysis of Respiratory Motion Based On Four-Dimensional Dose Accumulation in Liver Stereotactic Body Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, S; Kim, D; Kim, T; Kim, K; Cho, M; Shin, D; Suh, T [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Kim, S [Virginia Commonwealth University, Richmond, VA (United States); Park, S [Uijeongbu St.Mary’s Hospital, GyeongGi-Do (Korea, Republic of)

    2015-06-15

    Purpose: Respiratory motion in thoracic and abdominal region could lead to significant underdosing of target and increased dose to healthy tissues. The aim of this study is to evaluate the dosimetric effect of respiratory motion in conventional 3D dose by comparing 4D deformable dose in liver stereotactic body radiotherapy (SBRT). Methods: Five patients who had previously treated liver SBRT were included in this study. Four-dimensional computed tomography (4DCT) images with 10 phases for all patients were acquired on multi-slice CT scanner (Siemens, Somatom definition). Conventional 3D planning was performed using the average intensity projection (AIP) images. 4D dose accumulation was calculated by summation of dose distribution for all phase images of 4DCT using deformable image registration (DIR) . The target volume and normal organs dose were evaluated with the 4D dose and compared with those from 3D dose. And also, Index of achievement (IOA) which assesses the consistency between planned dose and prescription dose was used to compare target dose distribution between 3D and 4D dose. Results: Although the 3D dose calculation considered the moving target coverage, significant differences of various dosimetric parameters between 4D and 3D dose were observed in normal organs and PTV. The conventional 3D dose overestimated dose to PTV, however, there was no significant difference for GTV. The average difference of IOA which become ‘1’ in an ideal case was 3.2% in PTV. The average difference of liver and duodenum was 5% and 16% respectively. Conclusion: 4D dose accumulation which can provide dosimetric effect of respiratory motion has a possibility to predict the more accurate delivered dose to target and normal organs and improve treatment accuracy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the

  14. Impact of post-implant dosimetric parameters on the quality of life of patients treated with low-dose rate brachytherapy for localised prostate cancer: results of a single-institution study

    International Nuclear Information System (INIS)

    Veccia, Antonello; Caffo, Orazio; Fellin, Giovanni; Mussari, Salvatore; Ziglio, Francesco; Maines, Francesca; Tomio, Luigi; Galligioni, Enzo

    2015-01-01

    To assess the relationship between dosimetric parameters and the quality of life (QL) outcomes of patients with low-intermediate-risk localised prostate cancer (LPC) treated with low-dose-rate brachytherapy (LDR-BT). We evaluated the participants in two consecutive prospective studies of the QL of patients treated with LDR-BT for LPC. QL was evaluated by means of a patient-completed questionnaire assessing non functional [physical (PHY) and psychological (PSY) well-being, physical autonomy (POW), social relationships (REL)] and functional scales [urinary (URI), rectal (REC), and sexual (SEX) function]; a scale for erectile function (ERE) was included in the second study. Urethra (D10 ≤ 210 Gy) and rectal wall constraints (V100 ≤ 0.5 cc) were used for pre-planning dosimetry and were assessed with post planning computerized tomography one month later for each patient. QL was assessed in 251 LPC patients. Dosimetry did not influence the non-functional scales. As expected, a progressive impairment in sexual and erectile function was reported one month after LDR-BT, and became statistically significant after the third year. Rectal function significantly worsened after LDR-BT, but the differences progressively decreased after the 1-year assessment. Overall urinary function significantly worsened immediately after LDR-BT and then gradually improved over the next three years. Better outcomes were reported for V100 rectal wall volumes of ≤ 0.5 cc and D10 urethra values of ≤ 210 Gy. The findings of this study show that dosimetric parameters influence only functional QL outcomes while non-functional outcomes are only marginally influenced

  15. Amorphous chalcogenide semiconductors for solid state dosimetric systems of high-energetic ionizing radiation

    International Nuclear Information System (INIS)

    Shpotyuk, O.

    1997-01-01

    The application possibilities of amorphous chalcogenide semiconductors use as radiation-sensitive elements of high-energetic (E > 1 MeV) dosimetric systems are analysed. It is shown that investigated materials are characterized by more wide region of registered absorbed doses and low temperature threshold of radiation information bleaching in comparison with well-known analogies based on coloring oxide glasses. (author)

  16. Validation of the implementation of IMRT with three dosimetric methods of independent verification

    International Nuclear Information System (INIS)

    Tortosa Oliver, R. A.; Chinillach ferrando, N.; Alonso Arrizabalaga, S.; Campayo Esteban, J. M.; Morales Marco, J. C.; Soler Catalan, P.; Andreu Martinez, F. J.

    2013-01-01

    The TG119 is a simple and clear framework to verify the implementation of IMRT technique in a radiotherapy service. Verifications of this document recommended tests conducted with the three dosimetric methods listed above, allow to affirm that our Center is within the margins of tolerance considered suitable in the TG119 for the clinical implementation of IMRT. (Author)

  17. Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Wiersma, R. D.; Xing, L.

    2007-01-01

    Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the ''overshoot phenomena.'' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of ∼0.27 MU and ∼0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are

  18. Analysis of FT-IR for dosimetric characterization of poly(vinylidene fluoride - hexafluoropropylene) irradiated with high doses of gamma radiation

    International Nuclear Information System (INIS)

    Liz, Otavio Souza Rocha; Medeiros, Adriana de Souza

    2011-01-01

    Polymeric materials when exposed to ionizing radiation undergo changes such as the crosslinking and chain oxidation. Recently, the optical absorption intensities in the ultraviolet visible region (273 nm) due to radio- induction of conjugated C=C bonds in P(VDF-TrFE) copolymers has been successfully used for high dose dosimetry purposes in gamma fields ranging from 0.1 to 200 kGy. In this context, the interest of performing a systematic investigation on another fluorinated copolymer of PVDF, the (Polyvinylidene fluoride - hexa fluoro propylene) [P(VDF- HFP)] has come to light, not only for UV-VIS range but also for the near and medium infrared ranges. In this investigation FTIR and UV-Vis spectra, acquired before and after irradiation, were used to investigate the relationship between optical absorbance and delivered gamma doses ranging from 100 to 3,000 kGy. The results indicate that the absorption band at 1729 cm-1, originated by the chain oxidation through the radioinduction of C=O bonds, presents an unambiguous behavior with the delivered gamma doses in a very large extension, ranging from 0 to 1,000 kGy. This results lead to conclude that P(VDF-HFP) copolymer shows excellent dosimetric properties which make it able to be investigated as a high dose dosimeter

  19. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-05-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario. Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old. Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  20. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-04-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario.Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old.Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  1. Dosimetric feature of natural biotite mineral

    International Nuclear Information System (INIS)

    Kalita, J.M.; Wary, G.

    2015-01-01

    A thermoluminescence (TL) study relevant to radiation dosimetry has been carried out for X-ray irradiated biotite mineral under un-annealed and different annealed (473, 573, 673 and 773 K) conditions. Some significant variations in dosimetric characteristics have been observed with annealing treatment. Due to generation of an additional shallow trap level at depth 0.78 eV in 673 and 773 K annealed samples, the dose response is found to improve. For the 773 K annealed sample, a linear dose response has been observed from 10 to 1100 mGy. The fading is ∼13 % within 5 d after irradiation and onward it reduces to 7 % up to 60 d. Reproducibility of this (773 K) sample is excellent. After 10 recycles the coefficient of variations in the results for the 60, 180 and 1000 mGy dose-irradiated samples are found to be 0.97, 1.31 and 1.03 %, respectively. The potential use of biotite as a natural X-ray dosemeter is discussed. (authors)

  2. Dosimetric verification of a software for planning of radio therapeutical treatments

    International Nuclear Information System (INIS)

    Alfonso, R.; Huerta, U.; Alfonso, J.L.; Torres, M.

    1995-01-01

    A software for radiation treatment planning was recently developed by medical physicists at the Hermanos Ameijeiras Hospital in Havana. Selected locations in head and neck region were used to evaluate the reliability of calculated dose distributions in patients, taking as a reference the results of dosimetric measurements with TLD-700 powder in a RANDO type phantom. The different options is shown. Causes of discrepancies are analyzed and recommendations are made for the use of data acquisitions options

  3. Dosimetric Significance of the ICRP's Updated Guidance and Models, 1989-2003, and Implications for U.S. Federal Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, R.W.

    2003-09-10

    Over the past two decades the U.S. Environmental Protection Agency (EPA) has issued a series of Federal guidance documents for the purpose of providing the Federal and State agencies with technical information to assist their implementation of radiation protection programs. Currently recommended dose conversion factors, annual limits on intake, and derived air concentrations for intake of radionuclides are tabulated in Federal Guidance Report No. 11 (FGR 11), published in 1988. The tabulations in FGR 11 were based on dosimetric quantities and biokinetic and dosimetric models of the International Commission on Radiological Protection (ICRP) developed for application to occupational exposures. Since the publication of FGR 11 the ICRP has revised some of its dosimetric quantities and its models for workers and has also developed age-specific models and dose conversion factors for intake of radionuclides by members of the public. This report examines the extent of the changes in the inhalation and ingestion dose coefficients of FGR 11 implied by the updated recommendations of the ICRP, both for workers and members of the public.

  4. Dosimetric confirmation of a software for the design of radiotherapy

    International Nuclear Information System (INIS)

    Alfonso, R.; Huerta, U.; Torres, M.; Alonso, J.L.

    1995-01-01

    A software for radiotherapy treatment has been recently designed by specialists in medical physics form Hermanos Ameijeiras Clinical and Surgical Hospital. Several locations in the distributions of dose calculations. The results of dosimetric measurements with TLD-700 powder in a human-like manikin were taken as reference. The different options available for the entry of patients shape data are explained. A comparison of the results of measurements with calculations, is presented. Causes of discrepancies are analyzed and recommendations regarding the usefulness of the different for the collection of data from patients are made

  5. Dosimetry in radiodiagnosis. Individual irradiation card. Dosimetric application of electrets

    International Nuclear Information System (INIS)

    Lisbona, Albert.

    1981-09-01

    This study deals with a radiodiagnosis dosimetry, and contains two parts. First of all, the combination between a dosimetric data acquisition from an ionization chamber and a micro-computer allows the realization of individual irradiation card for a well established examination. The method is extensible to almost totality of radiological examinations. The second part describes the following of an original work about the application of electrets in radiodiagnosis dosimetry. At least a theorical study is shown; it takes account of different involving phenomena and allows a starting interpretation of experimental results [fr

  6. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Tsuruta, Yusuke; Nakata, Manabu; Higashimura, Kyoji; Nakamura, Mitsuhiro; Matsuo, Yukinori; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro

    2014-01-01

    Purpose: To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Methods: Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. Results: The results from AXB and XVMC agreed with measurements within ±3.0% for the lung-equivalent phantom with a 6 × 6 cm 2 field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ±3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124–358 s), 66.1 ± 16.0 s (range, 42–94 s), and 6.7 ± 1.1 s (range, 5–9 s) for XVMC, AXB, and AAA, respectively. Conclusions: In the phantom

  7. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.

    Science.gov (United States)

    Tsuruta, Yusuke; Nakata, Manabu; Nakamura, Mitsuhiro; Matsuo, Yukinori; Higashimura, Kyoji; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro

    2014-08-01

    To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. The results from AXB and XVMC agreed with measurements within ± 3.0% for the lung-equivalent phantom with a 6 × 6 cm(2) field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ± 3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124-358 s), 66.1 ± 16.0 s (range, 42-94 s), and 6.7 ± 1.1 s (range, 5-9 s) for XVMC, AXB, and AAA, respectively. In the phantom evaluations, AXB and XVMC agreed better with

  8. Internal dosimetric evaluation due to uranium aerosols; Evaluacion dosimetrica interna debido a aerosoles de uranio

    Energy Technology Data Exchange (ETDEWEB)

    Juan, Garcia Aguilar; Gustavo, Delgado Avila [Instituto Nacional de Investigaciones Nucleares, Salazar (Mexico)

    1991-07-01

    The present work has like object to carry out the internal dosimetric evaluation to the occupationally exposed personnel, due to the inhalation of aerosols of natural uranium and enriched in the pilot plant of nuclear fuel production of the National Institute of Nuclear Research.

  9. Motion range assessment in Rheumatoid Arthritis: a literature review

    Directory of Open Access Journals (Sweden)

    Melissa Andrea Jeannet Michaelsen Cardoso Mezzari

    2017-06-01

    Full Text Available Objective: The aim of this review is to describe the methods used for range of motion (ROM assessment in Rheumatoid Arthritis (RA in order to assist in the identification of the main limitations experienced by patients and thus contribute to the specific treatment of the most affected joints. Method: The methodology used was a critical review of the literature and the search was conducted in the capes portal, specifically in health care databases. The two MeSH descriptors “rheumatoid arthritis” and “mobility limitation” were used in the search, and also the term “range of motion”. Results: A total of 774 articles were found in the review and 446 were preselected based on title and abstract contents. After reading, 403 articles did not meet the inclusion criteria set in the study and were excluded. Thus, 43 articles were selected, which are summarized in a standardized manner. The studies do not approach the mobility of joints of RA patients, but they have in common the inclusion of ROM assessment to monitor the disease in a manner that is directly related to the function of the joints, especially the most compromised ones. Conclusion: We suggest the realization of thorough studies on joint involvement in order to outline interventions for preventing deformities generated by RA that compromise the quality of life of these patients. The studies could also contribute to disseminate such assessment practices among the multidisciplinary teams that provide assistance to these patients, optimizing the long-term care plan and taking into account the chronicity of the condition.

  10. Range-finding risk assessment of inhalation exposure to nanodiamonds in a laboratory environment.

    Science.gov (United States)

    Koivisto, Antti J; Palomäki, Jaana E; Viitanen, Anna-Kaisa; Siivola, Kirsi M; Koponen, Ismo K; Yu, Mingzhou; Kanerva, Tomi S; Norppa, Hannu; Alenius, Harri T; Hussein, Tareq; Savolainen, Kai M; Hämeri, Kaarle J

    2014-05-16

    This study considers fundamental methods in occupational risk assessment of exposure to airborne engineered nanomaterials. We discuss characterization of particle emissions, exposure assessment, hazard assessment with in vitro studies, and risk range characterization using calculated inhaled doses and dose-response translated to humans from in vitro studies. Here, the methods were utilized to assess workers' risk range of inhalation exposure to nanodiamonds (NDs) during handling and sieving of ND powder. NDs were agglomerated to over 500 nm particles, and mean exposure levels of different work tasks varied from 0.24 to 4.96 µg·m(-3) (0.08 to 0.74 cm(-3)). In vitro-experiments suggested that ND exposure may cause a risk for activation of inflammatory cascade. However, risk range characterization based on in vitro dose-response was not performed because accurate assessment of delivered (settled) dose on the cells was not possible. Comparison of ND exposure with common pollutants revealed that ND exposure was below 5 μg·m(-3), which is one of the proposed exposure limits for diesel particulate matter, and the workers' calculated dose of NDs during the measurement day was 74 ng which corresponded to 0.02% of the modeled daily (24 h) dose of submicrometer urban air particles.

  11. Range-Finding Risk Assessment of Inhalation Exposure to Nanodiamonds in a Laboratory Environment

    Directory of Open Access Journals (Sweden)

    Antti J. Koivisto

    2014-05-01

    Full Text Available This study considers fundamental methods in occupational risk assessment of exposure to airborne engineered nanomaterials. We discuss characterization of particle emissions, exposure assessment, hazard assessment with in vitro studies, and risk range characterization using calculated inhaled doses and dose-response translated to humans from in vitro studies. Here, the methods were utilized to assess workers’ risk range of inhalation exposure to nanodiamonds (NDs during handling and sieving of ND powder. NDs were agglomerated to over 500 nm particles, and mean exposure levels of different work tasks varied from 0.24 to 4.96 µg·m−3 (0.08 to 0.74 cm−3. In vitro-experiments suggested that ND exposure may cause a risk for activation of inflammatory cascade. However, risk range characterization based on in vitro dose-response was not performed because accurate assessment of delivered (settled dose on the cells was not possible. Comparison of ND exposure with common pollutants revealed that ND exposure was below 5 μg·m−3, which is one of the proposed exposure limits for diesel particulate matter, and the workers’ calculated dose of NDs during the measurement day was 74 ng which corresponded to 0.02% of the modeled daily (24 h dose of submicrometer urban air particles.

  12. Dosimetric characteristics of LKB:Cu,P solid TL detector

    International Nuclear Information System (INIS)

    Hashim, S.; Alajerami, Y.S.M.; Ghoshal, S.K.; Saleh, M.A.; Saripan, M.I.; Kadir, A.B.A.; Bradley, D.A.; Alzimami, K.

    2014-01-01

    The dosimetric characteristics of newly developed borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and NH 4 H 2 PO 4 are reported. Broad peaks in the absence of any sharp peak confirms the amorphous nature of the prepared glass. A simple glow curve of Cu doped sample is observed with a single prominent peak (T m ) at 220 °C. The TL intensity response shows an enhancement of ∼100 times due to the addition of CuO (0.1 mol%) to LKB compound. A further enhancement of the intensity by a factor of 3 from the addition of 0.25 mol% NH 4 H 2 PO 4 as a co-dopant impurity is attributed to the creation of extra electron traps with consequent increase in energy transfer of radiation recombination centers. The TL yield performance of LKB:Cu,P with Z eff ≈8.92 is approximately seventeen times less sensitive compared to LiF:Mg,Ti (TLD-100). The proposed dosimeter shows good linearity up to 10 3 Gy, minimal fading and photon energy independence. These attractive features offered by our dosimeter is expected to pave the way towards dosimetric applications. - Highlights: • The NH 4 H 2 PO 4 impurities are cross linked with the CuO defect. • The addition of NH 4 H 2 PO 4 as a co-dopant improved the TL intensity by a factor of 3. • The proposed dosimeter shows good linearity up to 10 3 Gy. • Minimal fading and photon energy independence were observed

  13. Dosimetric Analysis of Respiratory-Gated Radiotherapy for Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Xi Mian; Zhang Li; Liu Mengzhong; Deng Xiaowu; Huang Xiaoyan; Liu Hui

    2011-01-01

    The purpose of this study was to define individualized internal target volume (ITV) for hepatocellular carcinoma (HCC) using 4D computed tomography (4DCT), and to determine the geometric and dosimetric benefits of respiratory gating. Gross tumor volumes (GTVs) were contoured on 10 respiratory phases of 4DCT images for 12 patients with HCC. Three treatment plans were prepared using different planning target volumes (PTVs): (1) PTV 3D , derived from a single helical clinical target volume (CTV) plus conventional margins; (2) PTV 10phases , derived from ITV 10phases , which encompassed all 10 CTVs plus an isotropic margin of 0.8 cm; (3) PTV gating , derived from ITV gating , which encompassed three CTVs within gating-window at end-expiration plus an isotropic margin of 0.8 cm. The PTV 3D was the largest volume for all patients. The ITV-based plans and gating plans spared more normal tissues than 3D plans, especially the liver. Without increasing normal tissue complication probability of the 3D plans, the ITV-based plans allowed for increasing the calculated dose from 50.8 Gy to 54.7 Gy on average, and the gating plans could further escalate the dose to 58.5 Gy. Compared with ITV-based plans, the dosimetric gains with gating plan strongly correlated with GTV mobility in the craniocaudal direction. The ITV-based plans can ensure target coverage with less irradiation of normal tissues compared with 3D plans. Respiratory-gated radiotherapy can further reduce the target volumes to spare more surrounding tissues and allow dose escalation, especially for patients with tumor mobility >1 cm.

  14. Comparison of the dosimetric parameters in linear accelerators with flattening filter-free (FFF) and flattening filter (FF)

    International Nuclear Information System (INIS)

    Souza, Anderson S.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Moura, Eduardo S.; Rodrigues, Bruna T.; Souza, Daiane C.; Tiezzi, Rodrigo; Souza, Carla D.; Melo, Emerson R.; Camargo, Anderson R.; Batista, Talita Q.

    2015-01-01

    This paper discusses the main features associated with the dosimetric parameters between FFF and FF Linacs. A set of Varian TrueBeam Linac and Varian 23EX dosimetric measurements was acquired to perform the experimental measurements. The dose measurements were carried out in a water Blue phantom, with a waterproof ionization chambers: farmer ionization chamber (0.6 cm 3 ) and Exradin A1SL(0.053 cm 3 ) , for fields 5 x 5, 8 x 8, 10 x 10, 15 x 15, 30 x 30 cm 2 . The 6 MV FFF and FF was the energy used in this work. Percent Depth Dose (PDD) was the dosimetric parameters evaluated using a fixed Source Surface Distance of 100 cm. One depth were applied for the measurements, 10 cm (central axis) from the water surface. The 6 MV FFF showed less penetrating than the 6 MV FF. This is due to the removal flattening filter causes more lower energy photons on the central axis. The field sizes were equivalent for both FFF and FF. The main advantage in operate linear accelerators without flattening filter is due to the high doses rates delivered during the treatment. High doses rates could reduce the patient treatment time and may be beneficial for some treatment techniques such as IMRT and SRT. (author)

  15. Amorphous chalcogenide semiconductors for solid state dosimetric systems of high-energetic ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shpotyuk, O. [Pedagogical University, Czestochowa (Poland)]|[Institute of Materials, Lvov (Ukraine)

    1997-12-31

    The application possibilities of amorphous chalcogenide semiconductors use as radiation-sensitive elements of high-energetic (E > 1 MeV) dosimetric systems are analysed. It is shown that investigated materials are characterized by more wide region of registered absorbed doses and low temperature threshold of radiation information bleaching in comparison with well-known analogies based on coloring oxide glasses. (author). 16 refs, 1 tab.

  16. A novel track imaging system as a range counter

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z. [National Institute of Radiological Sciences (Japan); Matsufuji, N. [National Institute of Radiological Sciences (Japan); Tokyo Institute of Technology (Japan); Kanayama, S. [Chiba University (Japan); Ishida, A. [National Institute of Radiological Sciences (Japan); Tokyo Institute of Technology (Japan); Kohno, T. [Tokyo Institute of Technology (Japan); Koba, Y.; Sekiguchi, M.; Kitagawa, A.; Murakami, T. [National Institute of Radiological Sciences (Japan)

    2016-05-01

    An image-intensified, camera-based track imaging system has been developed to measure the tracks of ions in a scintillator block. To study the performance of the detector unit in the system, two types of scintillators, a dosimetrically tissue-equivalent plastic scintillator EJ-240 and a CsI(Tl) scintillator, were separately irradiated with carbon ion ({sup 12}C) beams of therapeutic energy from HIMAC at NIRS. The images of individual ion tracks in the scintillators were acquired by the newly developed track imaging system. The ranges reconstructed from the images are reported here. The range resolution of the measurements is 1.8 mm for 290 MeV/u carbon ions, which is considered a significant improvement on the energy resolution of the conventional ΔE/E method. The detector is compact and easy to handle, and it can fit inside treatment rooms for in-situ studies, as well as satisfy clinical quality assurance purposes.

  17. Dosimetric measurement of the disintegration rate of fission products

    International Nuclear Information System (INIS)

    Solymosi, J.; Nagy, L.G.; Zagyvai, P.

    1992-01-01

    Investigations on the disintegration rate of fission products of 238 U and 239 Pu are presented. The intensity of the β-and γ-radiation of fission products were measured continously in an interval of 1-1300 hours following the fission, offering the possibility for determining the general and specific characteristics of the individual fission products. A universal measuring procedure was elaborated for the rapid in situ determination of the dosimetric features of fission products, which is suitable for the accurate evaluation and prediction of external absorbed dose even in case of fission products of various origin and unknown composition. (author) 6 refs.; 7 figs.; 1 tab

  18. Radioecological and dosimetric consequences of Chernobyl accident in France

    International Nuclear Information System (INIS)

    Renaud, Ph.; Beaugelin, K.; Maubert, H.; Ledenvic, Ph.

    1997-01-01

    After ten years and the taking in account of numerous data, it can be affirmed that the dosimetric consequences of Chernobyl accident will have been limited in France. for the period 1986-2046, the individual middle efficient dose commitment, for the area the most reached by depositing is inferior to 1500 μSv, that represents about 1% of middle natural exposure in the same time. but mountains and forests can have more important surface activities than in plain. Everywhere else, it can be considered that the effects of Chernobyl accident are disappearing. the levels of cesium 137 are now often inferior to what they were before the accident. (N.C.)

  19. Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration

    International Nuclear Information System (INIS)

    Barnes, Elizabeth A.; Murray, Brad R.; Robinson, Donald M.; Underwood, Lori J.; Hanson, John; Roa, Wilson H.Y.

    2001-01-01

    Purpose:To examine the dosimetric benefit of self-gated radiotherapy at deep-inspiration breath hold (DIBH) in the treatment of patients with non-small-cell lung cancer (NSCLC). The relative contributions of tumor immobilization at breath hold (BH) and increased lung volume at deep inspiration (DI) in sparing high-dose lung irradiation (≥20 Gy) were examined. Methods and Materials:Ten consecutive patients undergoing radiotherapy for Stage I-IIIB NSCLC who met the screening criteria were entered on this study. Patients were instructed to BH at DI without the use of external monitors or breath-holding devices (self-gating). Computed tomography (CT) scans of the thorax were performed during free breathing (FB) and DIBH. Fluoroscopy screened for reproducible tumor position throughout DIBH, and determined the maximum superior-inferior (SI) tumor motion during both FB and DIBH. Margins used to define the planning target volume (PTV) from the clinical target volume included 1 cm for setup error and organ motion, plus an additional SI margin for tumor motion, as determined from fluoroscopy. Three conformal treatment plans were then generated for each patient, one from the FB scan with FB PTV margins, a second from the DIBH scan with FB PTV margins, and a third from the DIBH scan with DIBH PTV margins. The percent of total lung volume receiving ≥20 Gy (using a prescription dose of 70.9 Gy to isocenter) was determined for each plan. Results:Self-gating at DIBH was possible for 8 of the 10 patients; 2 patients were excluded, because they were not able to perform a reproducible DIBH. For these 8 patients, the median BH time was 23 (range, 19-52) s. The mean percent of total lung volume receiving ≥20 Gy under FB conditions (FB scan with FB PTV margins) was 12.8%. With increased lung volume alone (DIBH scan with FB PTV margins), this was reduced to 11.0%, tending toward a significant decrease in lung irradiation over FB (p=0.086). With both increased lung volume and tumor

  20. Dosimetric intercomparison between protons and electrons therapies applied to retinoblastoma

    International Nuclear Information System (INIS)

    Braga, Flavia Vieira

    2008-01-01

    In this work we propose a construction of a simple human eye model in order to simulate the dosimetric response for a treatment with protons and electrons in a retinoblastoma cancer. The computational tool used in this simulation was the Geant4 code, in the version 4.9.1, all these package are free and permit simulate the interaction of radiation with matter. In our simulation we use a box with 4 cm side, with water, for represent the human eye. The simulation was performed considering mono energetics beams of protons and electrons with energy range between 50 and 70 MeV for protons and 2 and 10 MeV for electrons. The simulation was based on the advanced hadron therapy example of the Geant 4 code. In these example the phantom is divided in voxels with 0.2 mm side and it is generated the energy deposited in each voxel. The simulation results show the energy deliver in each voxel, with these energie we can calculate the dose deposited in that region. We can see the dose profile of, proton and electron, and we can see in both cases that for protons the position of delivered dose is well know, that happen in the position where the proton stop, for electrons the energies is delivered along the way and pass the desired position for high dose deposition. (author)

  1. A real-time in vivo dosimetric verification method for high-dose rate intracavitary brachytherapy of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Qi Zhenyu; Deng Xiaowu; Cao Xinping; Huang Shaomin; Lerch, Michael; Rosenfeld, Anatoly [State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou 510060 (China) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou 510060 (China); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-11-15

    Purpose: A real-time in vivo dosimetric verification method using metal-oxide-semiconductor field effect transistor (MOSFET) dosimeters has been developed for patient dosimetry in high-dose rate (HDR) intracavitary brachytherapy of nasopharyngeal carcinoma (NPC). Methods: The necessary calibration and correction factors for MOSFET measurements in {sup 192}Iridium source were determined in a water phantom. With the detector placed inside a custom-made nasopharyngeal applicator, the actual dose delivered to the tumor was measured in vivo and compared to the calculated values using a commercial brachytherapy planning system. Results: Five MOSFETs were independently calibrated with the HDR source, yielding calibration factors of 0.48 {+-} 0.007 cGy/mV. The maximum sensitivity variation was no more than 7% in the clinically relevant distance range of 1-5 cm from the source. A total of 70 in vivo measurements in 11 NPC patients demonstrated good agreement with the treatment planning. The mean differences between the planned and the actually delivered dose within a single treatment fraction were -0.1%{+-} 3.8% and -0.1%{+-} 3.7%, respectively, for right and left side assessments. The maximum dose deviation was less than 8.5%. Conclusions: In vivo measurement using the real-time MOSFET dosimetry system is possible to evaluate the actual dose to the tumor received by the patient during a treatment fraction and thus can offer another line of security to detect and prevent large errors.

  2. Dosimetric predictors of hypothyroidism in oropharyngeal cancer patients treated with intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Chyan, Arthur; Chen, Josephine; Shugard, Erin; Lambert, Louise; Quivey, Jeanne M; Yom, Sue S

    2014-01-01

    Radiation to the neck has long been associated with an elevated risk of hypothyroidism development. The goal of the present work is to define dosimetric predictors of hypothyroidism in oropharyngeal cancer (OPC) patients treated with intensity-modulated radiation therapy. Data for 123 patients, with a median follow up of 4.6 years, were retrospectively analyzed. Patients with elevated thyroid-stimulating hormone levels or with a clinical diagnosis were categorized as hypothyroid. Patient demographic parameters, thyroid volume, mean thyroid dose, the percent of thyroid volume receiving minimum specified dose levels (VxxGy), and the absolute thyroid volume spared from specified dose levels (VSxxGy) were analyzed. Normal-tissue complication probability (NTCP) was also calculated using several recently published models. Thyroid volume and many radiation dosimetric parameters were statistically different in the hypothyroid group. For the patients with initial thyroid volumes of 8 cc or greater, several dosimetric parameters were found to define subgroups at statistically significant lower risk of developing hypothyroidism. Patients with VS45 Gy of at least 3 cc, VS50 Gy at least 5 cc, VS50 Gy at least 6 cc, V50 Gy below 45%, V50 Gy below 55%, or mean thyroid dose below 49 Gy had a 28-38% estimated risk of hypothyroidism at 3 years compared to a 55% risk for the entire study group. Patients with a NTCP of less than 0.75 or 0.8, calculated using recently published models, were also observed to have a lower risk of developing hypothyroidism. Based on long-term follow up data for OPC patients treated with IMRT, we recommend plan optimization objectives to reduce the volume of thyroid receiving over 45 Gy to significantly decrease the risk of developing hypothyroidism. The online version of this article (doi:10.1186/s13014-014-0269-4) contains supplementary material, which is available to authorized users

  3. Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

    International Nuclear Information System (INIS)

    Staton, Robert J.; Langen, Katja M.; Kupelian, Patrick A.; Meeks, Sanford L.

    2009-01-01

    In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about ±2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude (±2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of ±7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D 50 of organs at risk, the D 95 for planning target volumes (PTVs), and the local dose difference were used to

  4. A Combined Tissue Kinetics and Dosimetric Model of Respiratory Tissue Exposed to Radiation

    Energy Technology Data Exchange (ETDEWEB)

    John R. Ford

    2005-11-01

    Existing dosimetric models of the radiation response of tissues are essentially static. Consideration of changes in the cell populations over time has not been addressed realistically. For a single acute dose this is not a concern, but for modeling chronic exposures or fractionated acute exposures, the natural turnover and progression of cells could have a significant impact on a variety of endpoints. This proposal addresses the shortcomings of current methods by combining current dose-based calculation techniques with information on the cell turnover for a model tissue. The proposed model will examine effects at the single-cell level for an exposure of a section of human bronchiole. The cell model will be combined with Monte Carlo calculations of doses to cells and cell nuclei due to varying dose-rates of different radiation qualities. Predictions from the model of effects on survival, apoptosis rates, and changes in the number of cycling and differentiating cells will be tested experimentally. The availability of dynamic dosimetric models of tissues at the single-cell level will be useful for analysis of low-level radiation exposures and in the development of new radiotherapy protocols.

  5. The choice of statistical methods for comparisons of dosimetric data in radiotherapy

    International Nuclear Information System (INIS)

    Chaikh, Abdulhamid; Giraud, Jean-Yves; Perrin, Emmanuel; Bresciani, Jean-Pierre; Balosso, Jacques

    2014-01-01

    Novel irradiation techniques are continuously introduced in radiotherapy to optimize the accuracy, the security and the clinical outcome of treatments. These changes could raise the question of discontinuity in dosimetric presentation and the subsequent need for practice adjustments in case of significant modifications. This study proposes a comprehensive approach to compare different techniques and tests whether their respective dose calculation algorithms give rise to statistically significant differences in the treatment doses for the patient. Statistical investigation principles are presented in the framework of a clinical example based on 62 fields of radiotherapy for lung cancer. The delivered doses in monitor units were calculated using three different dose calculation methods: the reference method accounts the dose without tissues density corrections using Pencil Beam Convolution (PBC) algorithm, whereas new methods calculate the dose with tissues density correction for 1D and 3D using Modified Batho (MB) method and Equivalent Tissue air ratio (ETAR) method, respectively. The normality of the data and the homogeneity of variance between groups were tested using Shapiro-Wilks and Levene test, respectively, then non-parametric statistical tests were performed. Specifically, the dose means estimated by the different calculation methods were compared using Friedman’s test and Wilcoxon signed-rank test. In addition, the correlation between the doses calculated by the three methods was assessed using Spearman’s rank and Kendall’s rank tests. The Friedman’s test showed a significant effect on the calculation method for the delivered dose of lung cancer patients (p <0.001). The density correction methods yielded to lower doses as compared to PBC by on average (−5 ± 4.4 SD) for MB and (−4.7 ± 5 SD) for ETAR. Post-hoc Wilcoxon signed-rank test of paired comparisons indicated that the delivered dose was significantly reduced using density

  6. Life-Time Dosimetric Assessment for Mice and Rats Exposed in Reverberation Chambers of the 2-Year NTP Cancer Bioassay Study on Cell Phone Radiation.

    Science.gov (United States)

    Gong, Yijian; Capstick, Myles; Kuehn, Sven; Wilson, Perry; Ladbury, John; Koepke, Galen; McCormick, David L; Melnick, Ronald L; Kuster, Niels

    2017-12-01

    In this paper, we present the detailed life-time dosimetry analysis for rodents exposed in the reverberation exposure system designed for the two-year cancer bioassay study conducted by the National Toxicology Program of the National Institute of Environmental Health Sciences. The study required the well-controlled and characterized exposure of individually housed, unrestrained mice at 1900 MHz and rats at 900 MHz, frequencies chosen to give best uniformity exposure of organs and tissues. The wbSAR, the peak spatial SAR and the organ specific SAR as well as the uncertainty and variation due to the exposure environment, differences in the growth rates, and animal posture were assessed. Compared to the wbSAR, the average exposure of the high-water-content tissues (blood, heart, lung) were higher by ~4 dB, while the low-loss tissues (bone and fat) were less by ~9 dB. The maximum uncertainty over the exposure period for the SAR was estimated to be <49% (k=2) for the rodents whereas the relative uncertainty between the group was <14% (k=1). The instantaneous variation (averaged over 1 min) was <13% (k=1), which is small compared to other long term exposure research projects. These detailed dosimetric results empowers comparison with other studies and provides a reference for studies of long-term biological effects of exposure of rodents to RF energy.

  7. Assessment of the lower ESR dating range in Greek speleothems

    International Nuclear Information System (INIS)

    Bassiakos, Y.

    2001-01-01

    Pilot ESR dating studies on geologically young calcitic sinters were carried out, aiming at assessment of the lower ESR dating range in characteristic Greek speleoenvironments. Five stalactites were dated, coming from an ancient mining gallery, idle for the last 2,500 years, found on Siphnos island (Aegean). The calculated ages range between 1,7-2,0 ka. Medium to low measured external dose rates (aprox. 900 μGy/a) and very low measured radioelement concentration in samples are very usual in the Mediterranean environments. The study concludes that ESR dating of speleothems younger than two millenia is practically unattainable. Some geoarchaeological implications of the obtained ages are discussed. (author)

  8. Investigation of the dosimetric properties of an a-Si flat panel epid

    International Nuclear Information System (INIS)

    Fielding, A.L.; Jahangir, S.T.

    2004-01-01

    Full text: Electronic portal imaging devices (EPIDs) are primarily used as an electronic replacement for film to verify the set-up of radiotherapy patients based on imaged anatomy. There has recently been much interest in the use of amorphous silicon (a-Si) flat panel EPIDs for dosimetric verification in radiotherapy. The work presented here has been carried out to determine their suitability for dosimetric applications by investigating some of the basic response characteristics and the implications these might have. The measurements reported in this paper were performed using 6-MV photon beams from an Elekta Precise linear accelerator fitted with Elekta iViewGT amorphous silicon flat panel EPIDs. Measurements were performed to investigate the response of the EPID as a function of exposure and field size. Similar measurements were made with an ionisation chamber for comparison. Further measurements were carried out to investigate the response of the EPID to multiple low dose exposures (e.g. 5x2 MU) such as might be encountered in Intensity Modulated Radiotherapy (IMRT). This was compared with the response to a single high dose exposure (e.g. 10 MU) and repeated for a range of exposures. The results show the response of the EPID, to a good approximation, to be linear with dose over the range of 1 -200 MU. However, 'under-responses' in the EPID of up to 5% were seen at the lowest exposures. For multiple low dose segments the sum of the EPID responses was found to be less than the response to the same total exposure in a single large segment. This effect reduces with increase in the magnitude of the low dose segments. The variation in EPID response with field size was found to be greater than that indicated by the ionisation chamber. The results show that the a-Si detector responds to dose, to a good approximation, in a linear manner. The EPID under-response at low doses is thought to be related to the so called ghosting effect. Each image frame has a residual

  9. SU-F-T-366: Dosimetric Parameters Enhancement of 120-Leaf Millennium MLC Using EGSnrc and IAEA Phase-Space Data

    International Nuclear Information System (INIS)

    Haddad, K; Alopoor, H

    2016-01-01

    Purpose: Recently, the multileaf collimators (MLC) have become an important part of any LINAC collimation systems because they reduce the treatment planning time and improves the conformity. Important factors that affects the MLCs collimation performance are leaves material composition and their thickness. In this study, we investigate the main dosimetric parameters of 120-leaf Millennium MLC including dose in the buildup point, physical penumbra as well as average and end leaf leakages. Effects of the leaves geometry and density on these parameters are evaluated Methods: From EGSnrc Monte Carlo code, BEAMnrc and DOSXYZnrc modules are used to evaluate the dosimetric parameters of a water phantom exposed to a Varian xi for 100cm SSD. Using IAEA phasespace data just above MLC (Z=46cm) and BEAMnrc, for the modified 120-leaf Millennium MLC a new phase space data at Z=52cm is produces. The MLC is modified both in leaf thickness and material composition. EGSgui code generates 521ICRU library for tungsten alloys. DOSXYZnrc with the new phase space evaluates the dose distribution in a water phantom of 60×60×20 cm3 with voxel size of 4×4×2 mm3. Using DOSXYZnrc dose distributions for open beam and closed beam as well as the leakages definition, end leakage, average leakage and physical penumbra are evaluated. Results: A new MLC with improved dosimetric parameters is proposed. The physical penumbra for proposed MLC is 4.7mm compared to 5.16 mm for Millennium. Average leakage in our design is reduced to 1.16% compared to 1.73% for Millennium, the end leaf leakage suggested design is also reduced to 4.86% compared to 7.26% of Millennium. Conclusion: The results show that the proposed MLC with enhanced dosimetric parameters could improve the conformity of treatment planning.

  10. SU-F-T-366: Dosimetric Parameters Enhancement of 120-Leaf Millennium MLC Using EGSnrc and IAEA Phase-Space Data

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, K; Alopoor, H [Shiraz University, Shiraz, I.R. Iran (Iran, Islamic Republic of)

    2016-06-15

    Purpose: Recently, the multileaf collimators (MLC) have become an important part of any LINAC collimation systems because they reduce the treatment planning time and improves the conformity. Important factors that affects the MLCs collimation performance are leaves material composition and their thickness. In this study, we investigate the main dosimetric parameters of 120-leaf Millennium MLC including dose in the buildup point, physical penumbra as well as average and end leaf leakages. Effects of the leaves geometry and density on these parameters are evaluated Methods: From EGSnrc Monte Carlo code, BEAMnrc and DOSXYZnrc modules are used to evaluate the dosimetric parameters of a water phantom exposed to a Varian xi for 100cm SSD. Using IAEA phasespace data just above MLC (Z=46cm) and BEAMnrc, for the modified 120-leaf Millennium MLC a new phase space data at Z=52cm is produces. The MLC is modified both in leaf thickness and material composition. EGSgui code generates 521ICRU library for tungsten alloys. DOSXYZnrc with the new phase space evaluates the dose distribution in a water phantom of 60×60×20 cm3 with voxel size of 4×4×2 mm3. Using DOSXYZnrc dose distributions for open beam and closed beam as well as the leakages definition, end leakage, average leakage and physical penumbra are evaluated. Results: A new MLC with improved dosimetric parameters is proposed. The physical penumbra for proposed MLC is 4.7mm compared to 5.16 mm for Millennium. Average leakage in our design is reduced to 1.16% compared to 1.73% for Millennium, the end leaf leakage suggested design is also reduced to 4.86% compared to 7.26% of Millennium. Conclusion: The results show that the proposed MLC with enhanced dosimetric parameters could improve the conformity of treatment planning.

  11. A spectrophotometric readout for γ irradiated alanine solution - a dosimetric application

    International Nuclear Information System (INIS)

    Marzouk, Asma

    2007-01-01

    Alanine is a stable dosimeter of reference in its solid state. Its installation in solution as being a dosimetric system of routine remains very useful. A follow-up of the behaviour of the irradiated alanine solution with 15 kGy according to the concentration is carried out by UV-Visible spectrophotometry. The results obtained prove the difficulty in analytical studies of the radiolysis of aqueous solutions by optical absorption due to the ambiguous broad spectra of the species and the reaction products. (Author). 47 refs

  12. Biokinetic and dosimetric studies of 188Re-hyaluronic acid: a new radiopharmaceutical for treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura; Nadali, Anna; Zangoni, Elena; Banzato, Alessandra; Rondina, Maria; Rosato, Antonio; Mazzi, Ulderico

    2009-01-01

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: 188 Re-HA was prepared by a direct labelling method to produce a ReO(O-COO) 2 -type coordination complex. 188 Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and aspartate aminotranferase (ALT) levels in mice were assessed and the liver maximum tolerated dose (MTD) of 188 Re-HA was determined. Results: A stable complex of 188 Re-HA was obtained with high radiochemical purity (>90%) and low serum protein binding (2%). Biokinetic studies showed a rapid blood clearance (T 1/2 α=21 min). Four hours after administration, 188 Re-HA was almost totally removed from the blood by the liver due to the selective uptake via HA-specific receptors (73.47±5.11% of the injected dose). The liver MTD in mice was ∼40 Gy after 7.4 MBq of 188 Re-HA injection. Conclusions: 188 Re-HA complex showed good stability, pharmacokinetic and dosimetric characteristics that confirm its potential as a new agent for HCC radiation therapy.

  13. Dosimetric Characteristics of a LKB:Cu,Mg Solid Thermoluminescence Detector

    International Nuclear Information System (INIS)

    Alajerami Yasser Saleh Mustafa; Hashim Suhairul; Ramli Ahmad Termizi; Saleh Muneer Aziz; Kadir Ahmad Bazlie Bin Abdul; Saripan, Mohd. Iqbal

    2013-01-01

    We present the main thermoluminescence characteristics of a newly borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and MgO. An enhancement of about three times has been shown with the increment of 0.1mol% MgO as a co-dopant impurity. The effects of dose linearity, storage capacity, effective atomic number and energy dose response are studied. The proposed dosimeter shows a simple glow curve, good linearity up to 10 3 Gy, close effective atomic number and photon energy independence. The current results suggest using the proposed dosimeter in different dosimetric applications

  14. Method of accounting and suppressing the instability of dosimetric information

    International Nuclear Information System (INIS)

    Fejtek, Ya.

    1977-01-01

    To account for dosimetric information instability differential and integral correcting factors are proposed. The differential factor converts signals of dosimeters irradiated during short but different periods of time into equivalent signals related to a certain period of time. The factor excludes the effect of signal instability in the case of short exposures. The integral factor represents a generalization of the differential one for prolonged exposures. The statistical integral factor is derived. An example of processing experimental data using the analytical method developed is presented. The method is pointed out to have been introduced in the state personal dosimetry service in Czechoslovakia [ru

  15. Dosimetric study of the total corporal irradiation with high energy photons: Comparison between a linac mevatron KD and a bomb of 60CO Rokus M-132

    International Nuclear Information System (INIS)

    Bernal, M. A.; Silvestre, I

    2001-01-01

    Several dosimetric aspects of a 6 0 Co beam and another of 15 MV R X, of a linear accelerator, used for the Whole-Body Irradiation (WBI), as part of the bone marrow transplants, are studied. The lineal accelerator offers better beam characteristics. The dosimetric field is bigger and offers smaller dimness, which facilitates a higher dose homogeneity along the patient [es

  16. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd source

    International Nuclear Information System (INIS)

    Sadeghi, Mahdi; Hosseini, Hamed; Raisali, Gholamreza

    2008-01-01

    Full text: The use of 103 Pd seed sources for permanent prostate implantation has become a popular brachytherapy application. As recommended by AAPM the dosimetric characteristics of the new source must be determined using experimental and Monte Carlo simulations, before its use in clinical applications thus The goal of this report is the experimental and theoretical determination of the dosimetric characteristics of this source following the recommendations in the AAPM TG-43U1 protocol. Figure 1 shows the geometry of the IRA- 103 Pd source. The source consists of a cylindrical silver core, 0.3 cm long x 0.05 cm in diameter, onto which 0.5 nm layer of 103 Pd has been uniformly adsorbed. The effective active length of source is 0.3 cm and the silver core encapsulated inside a hollow titanium tube with 0.45 cm long, 0.07 cm and 0.08 inner and outer diameters and two caps. The Monte Carlo N-Particle (MCNP) code, version 4C, was used to determine the relevant dosimetric parameters of the source. The geometry of the Monte Carlo simulation performed in this study consisted of a sphere with 30 cm diameter. Dose distributions around this source were measured in two Perspex phantom using enough TLD chips. For these measurements, slabs of Perspex material were machined to accommodate the source and TLD chips. A value of 0.67± 1% cGy.h -1 .U -1 for, Λ, was calculated as the ratio of d(r 0 ,θ 0 ) and s K , that may be compared with Λ values obtained for 103 Pd sources. Result of calculations and measurements values of dosimetric parameters of the source including radial dose function, g(r), and anisotropy function, F(r,θ), has been shown in separate figures. The radial dose function, g(r), for the IRA- 103 Pd source and other 103 Pd sources is included in Fig. 2. Comparison between measured and Monte Carlo simulated dose function, g(r), and anisotropy function, F(r,θ), of this source demonstrated that they are in good agreement with each other and The value of Λ is

  17. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mirandola, Alfredo, E-mail: mirandola@cnao.it; Molinelli, S.; Vilches Freixas, G.; Mairani, A.; Gallio, E.; Panizza, D.; Russo, S.; Ciocca, M. [Fondazione CNAO, strada Campeggi 53, Pavia 27100 (Italy); Donetti, M. [INFN, Torino 10125, Italy and Fondazione CNAO, strada Campeggi 53, Pavia 27100 (Italy); Magro, G. [INFN–Dipartimento di Fisica, Università degli Studi di Pavia, Via U. Bassi 6, Pavia 27100, Italy and Fondazione CNAO, strada Campeggi 53, Pavia 27100 (Italy); Giordanengo, S. [INFN, Torino 10125 (Italy); Orecchia, R. [Fondazione CNAO, strada Campeggi 53, Pavia 27100, Italy and Radiotherapy Division, European Institute of Oncology, Via Ripamonti 435, Milano 20141 (Italy)

    2015-09-15

    Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA Monte Carlo code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per monitor unit using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured full width at half maximum (FWHM) of the pencil beam in air at the isocenter was energy-dependent for both particle species: in particular, for protons, the spot size ranged from 0.7 to 2.2 cm. For carbon ions, two sets of spot size are available: FWHM ranged from 0.4 to 0.8 cm (for the smaller spot size) and from 0.8 to 1.1 cm (for the larger one). The spot position was accurate to within ±1 mm over the whole 20 × 20 cm{sup 2} scan field; homogeneity in a uniform squared field was within ±5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements

  18. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

    International Nuclear Information System (INIS)

    Mirandola, Alfredo; Molinelli, S.; Vilches Freixas, G.; Mairani, A.; Gallio, E.; Panizza, D.; Russo, S.; Ciocca, M.; Donetti, M.; Magro, G.; Giordanengo, S.; Orecchia, R.

    2015-01-01

    Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA Monte Carlo code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per monitor unit using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured full width at half maximum (FWHM) of the pencil beam in air at the isocenter was energy-dependent for both particle species: in particular, for protons, the spot size ranged from 0.7 to 2.2 cm. For carbon ions, two sets of spot size are available: FWHM ranged from 0.4 to 0.8 cm (for the smaller spot size) and from 0.8 to 1.1 cm (for the larger one). The spot position was accurate to within ±1 mm over the whole 20 × 20 cm"2 scan field; homogeneity in a uniform squared field was within ±5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements

  19. SU-E-J-165: Dosimetric Impact of Liver Rotations in Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pinnaduwage, D; Paulsson, A; Sudhyadhom, A; Chen, J; Chang, A; Anwar, M; Gottschalk, A; Yom, S S.; Descovich, M [University of California San Francisco, San Francisco, CA (United States)

    2015-06-15

    Purpose: Often in liver stereotactic body radiotherapy a single fiducial is implanted near the tumor for image-guided treatment delivery. In such cases, rotational corrections are calculated based on the spine. This study quantifies rotational differences between the spine and liver, and investigates the corresponding dosimetric impact. Methods: Seven patients with 3 intrahepatic fiducials and 4DCT scans were identified. The planning CT was separately co-registered with 4 phases of the 4DCT (0%, 50%, 100% inhale and 50% exhale) by 1) rigid registration of the spine, and 2) point-based registration of the 3 fiducials. Rotation vectors were calculated for each registration. Translational differences in fiducial positions between the 2 registrations methods were investigated. Dosimetric impact due to liver rotations and deformations was assessed using critical structures delineated on the 4DCT phases. For dose comparisons, a single fiducial was translationally aligned following spine alignment to represent what is typically done in the clinic. Results: On average, differences between spine and liver rotations during the 0%, 50%, 100% inhale, and 50% exhale phases were 3.23°, 3.27°, 2.26° and 3.11° (pitch), 3.00°, 2.24°, 3.12° and 1.73° (roll), and 1.57°, 1.98°, 2.09° and 1.36° (yaw), respectively. The maximum difference in rotations was 12°, with differences of >3° seen in 14/28 (pitch), 10/28 (roll), and 6/28 (yaw) cases. Average fiducial displacements of 2.73 (craniocaudal), 1.04 (lateral) and 1.82 mm (vertical) were seen. Evaluating percent dose differences for 5 patients at the peaks of the respiratory cycle, the maximum dose to the duodenum, stomach, bowel and esophagus differed on average by 11.4%, 5.3%, 11.2% and 49.1% between the 2 registration methods. Conclusion: Lack of accounting for liver rotation during treatment might Result in clinically significant dose differences to critical structures. Both rotational and translational deviations

  20. Neutron sources and its dosimetric characteristics

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado S, G.A.; Gallego D, E.; Lorente F, A.

    2005-01-01

    By means of Monte Carlo methods the spectra of the produced neutrons 252 Cf, 252 Cf/D 2 O, 241 Am Be, 239 Pu Be, 140 La Be, 239 Pu 18 O 2 and 226 Ra Be have been calculated. With the information of the spectrum it was calculated the average energy of the neutrons of each source. By means of the fluence coefficients to dose it was determined, for each one of the studied sources, the fluence factors to dose. The calculated doses were H, H * (10), H p,sIab (10, 0 0 ), E AP and E ISO . During the phase of the calculations the sources were modeled as punctual and their characteristics were determined to 100 cm in the hole. Also, for the case of the sources of 239 Pu Be and 241 Am Be, were carried out calculations modeling the sources with their respective characteristics and the dosimetric properties were determined in a space full with air. The results of this last phase of the calculations were compared with the experimental results obtained for both sources. (Author)

  1. Hellsgate Winter Range : Wildlife Mitigation Project. Preliminary Environmental Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1995-01-01

    The Bonneville Power Administration proposes funding the Hellsgate Winter Range Wildlife Mitigation Project in cooperation with the Colville Convederated Tribes and Bureau of Indian Affairs. This Preliminary Environmental Assessment examines the potential environmental effects of acquiring and managing property for wildlife and wildlife habitat within a large project area. The Propose action is intended to meet the need for mitigation of wildlife and wild life habitat that was adversely affected by the construction of Grand Coulee and Chief Joseph Dams and their reservoirs.

  2. Dosimetric characterization of KMgF{sub 3}:Tb+PTFE; Caracterizacion dosimetrica de KMgF{sub 3}:Tb+PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez R, M. I.; Garcia S, L.; Villicana M, M.; Huirache A, R.; Apolinar C, J. [Universidad Michoacana de San Nicolas de Hidalgo, Facultad de Ingenieria Quimica, Francisco J. Mujica s/n, Ciudad Universitaria, Col. Felicitas del Rio, 58030 Morelia, Michoacan (Mexico); Gonzalez M, P. R., E-mail: itcraf_15@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2017-10-15

    In this work the results obtained from the dosimetric characterization of the new radiation detectors of KMgF{sub 3}:Tb+PTFE are presented. The host salt was obtained by means of the microwave technique, with the polycrystalline powder obtained, dosimeters were made in tablet form, using as Ptfe binder. The thermoluminescent response of these new detectors presented a linear behavior, in the dose range between 1 and 1000 Gy of {sup 60}Co gamma radiation, the reproducibility test in the measurements, during ten cycles of heat treatment, irradiation and reading presented ± 3.7% Ds, in the stability test of thermoluminescent signal, during two months showed that the fading is practically null. Due to the results obtained, this new detector could be very useful for the dosimetry of ionizing radiation in different clinical applications. (Author)

  3. SU-D-BRE-03: Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy

    International Nuclear Information System (INIS)

    Zhang, Y; Giebeler, A; Mascia, A; Piskulich, F; Perles, L; Lepage, R; Dong, L

    2014-01-01

    Purpose: To quantitatively evaluate dosimetric consequence of spot size variations and validate beam-matching criteria for commissioning a pencil beam model for multiple treatment rooms. Methods: A planning study was first conducted by simulating spot size variations to systematically evaluate dosimetric impact of spot size variations in selected cases, which was used to establish the in-air spot size tolerance for beam matching specifications. A beam model in treatment planning system was created using in-air spot profiles acquired in one treatment room. These spot profiles were also acquired from another treatment room for assessing the actual spot size variations between the two treatment rooms. We created twenty five test plans with targets of different sizes at different depths, and performed dose measurement along the entrance, proximal and distal target regions. The absolute doses at those locations were measured using ionization chambers at both treatment rooms, and were compared against the calculated doses by the beam model. Fifteen additional patient plans were also measured and included in our validation. Results: The beam model is relatively insensitive to spot size variations. With an average of less than 15% measured in-air spot size variations between two treatment rooms, the average dose difference was −0.15% with a standard deviation of 0.40% for 55 measurement points within target region; but the differences increased to 1.4%±1.1% in the entrance regions, which are more affected by in-air spot size variations. Overall, our single-room based beam model in the treatment planning system agreed with measurements in both rooms < 0.5% within the target region. For fifteen patient cases, the agreement was within 1%. Conclusion: We have demonstrated that dosimetrically equivalent machines can be established when in-air spot size variations are within 15% between the two treatment rooms

  4. Development of new chemical dosimeter for low dose range

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.; Adhikari, S.

    2012-01-01

    Accurate measurement of low dose radiation in complex systems is of utmost importance in radiation biology and related areas. Ferrous Benzoic acid Xylenol orange (FBX) system is being widely used for measurement of low dose gamma radiation because of its reproducibility and precision. However, an additional step, i.e., dissolution of benzoic acid in water at higher temperature followed by cooling at room temperature is involved for the preparation of this dosimeter. This makes it inconvenient as a ready to use dosimeter. In the present work, the organic molecule, sorbitol has been used for measurement of low doses of radiation. The advantages of using sorbitol are its ready availability and instantaneous water solubility. Owing to its dissolution at room temperature, possible errors those are involved in calculation of dose due to thermal oxidation of ferrous ions during preparation of the FBX dosimetric solution could be made insignificant in the proposed dosimeter. In the present system, sorbitol acts as radiolytic sensitizer for the oxidation of ferrous ion, and xylenol orange forms a 1:1 complex specifically with ferric ions. Thus, the analytical detection limit of ferric ions is enhanced compared to other systems. Final composition of the dosimetric solution is; 0.5 mol/m 3 xylenol orange, 10 mol/m 3 sorbitol and 0.2 mol/m 3 ferrous ion in 50 mol/m 3 sulfuric acid. Radiolytic sensitization in combination with analytical enhancement of the ferrous based system, allows us to measure radiation dose in the range of 0.05 Gy–12 Gy with ease and high reproducibility.

  5. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    International Nuclear Information System (INIS)

    Jiang, H; Lee, Y; Pokhrel, D; Badkul, R

    2015-01-01

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators

  6. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, H; Lee, Y; Pokhrel, D; Badkul, R [University of Kansas Hospital, Kansas City, KS (United States)

    2015-06-15

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

  7. Dosimetric properties of a novel brachytherapy balloon applicator for the treatment of malignant brain-tumor resection-cavity margins

    International Nuclear Information System (INIS)

    Dempsey, James F.; Williams, Jeffery A.; Stubbs, James B.; Patrick, Timothy J.; Williamson, Jeffrey F.

    1998-01-01

    Purpose: This paper characterizes the dosimetric properties of a novel balloon brachytherapy applicator for the treatment of the tissue surrounding the resection cavity of a malignant brain tumor. Methods and Materials: The applicator consists of an inflatable silicone balloon reservoir attached to a positionable catheter that is intraoperatively implanted into the resection cavity and postoperatively filled with a liquid radionuclide solution. A simple dosimetric model, valid in homogeneous media and based on results from Monte Carlo photon-transport simulations, was used to determine the dosimetric characteristics of spherical geometry balloons filled with photon-emitting radionuclide solutions. Fractional depth-dose (FDD) profiles, along with activity densities, and total activities needed to achieve specified dose rates were studied as a function of photon energy and source-containment geometry. Dose-volume histograms (DVHs) were calculated to compare idealized balloon-applicator treatments to conventional 125 I seed volume implants. Results: For achievable activity densities and total activities, classical low dose rate (LDR) treatments of residual disease at distances of up to 1 cm from the resection cavity wall are possible with balloon applicators having radii between 0.5 cm and 2.5 cm. The dose penetration of these applicators increases approximately linearly with balloon radius. The FDD profile can be made significantly more or less penetrating by combining selection of radionuclide with source-geometry manipulation. Comparisons with 125 I seed-implant DVHs show that the applicator can provide a more conformal therapy with no target tissue underdosing, less target tissue overdosing, and no healthy tissue ''hot spots;'' however, more healthy tissue volume receives a dose of the prescribed dosage or less. Conclusions: This device, when filled with 125 I solution, is suitable for classical LDR treatments and may be preferable to 125 I interstitial

  8. WE-AB-209-02: A New Inverse Planning Framework with Principle-Based Modeling of Inter-Structural Dosimetric Tradeoffs

    International Nuclear Information System (INIS)

    Liu, H; Dong, P; Xing, L

    2016-01-01

    Purpose: Traditional radiotherapy inverse planning relies on the weighting factors to phenomenologically balance the conflicting criteria for different structures. The resulting manual trial-and-error determination of the weights has long been recognized as the most time-consuming part of treatment planning. The purpose of this work is to develop an inverse planning framework that parameterizes the inter-structural dosimetric tradeoff among with physically more meaningful quantities to simplify the search for a clinically sensible plan. Methods: A permissible dosimetric uncertainty is introduced for each of the structures to balance their conflicting dosimetric requirements. The inverse planning is then formulated as a convex feasibility problem, which aims to generate plans with acceptable dosimetric uncertainties. A sequential procedure (SP) is derived to decompose the model into three submodels to constrain the uncertainty in the planning target volume (PTV), the critical structures, and all other structures to spare, sequentially. The proposed technique is applied to plan a liver case and a head-and-neck case and compared with a conventional approach. Results: Our results show that the strategy is able to generate clinically sensible plans with little trial-and-error. In the case of liver IMRT, the fractional volumes to liver and heart above 20Gy are found to be 22% and 10%, respectively, which are 15.1% and 33.3% lower than that of the counterpart conventional plan while maintaining the same PTV coverage. The planning of the head and neck IMRT show the same level of success, with the DVHs for all organs at risk and PTV very competitive to a counterpart plan. Conclusion: A new inverse planning framework has been established. With physically more meaningful modeling of the inter-structural tradeoff, the technique enables us to substantially reduce the need for trial-and-error adjustment of the model parameters and opens new opportunities of incorporating prior

  9. WE-AB-209-02: A New Inverse Planning Framework with Principle-Based Modeling of Inter-Structural Dosimetric Tradeoffs

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Dong, P; Xing, L [Stanford University School of Medicine, Stanford, CA (United States)

    2016-06-15

    Purpose: Traditional radiotherapy inverse planning relies on the weighting factors to phenomenologically balance the conflicting criteria for different structures. The resulting manual trial-and-error determination of the weights has long been recognized as the most time-consuming part of treatment planning. The purpose of this work is to develop an inverse planning framework that parameterizes the inter-structural dosimetric tradeoff among with physically more meaningful quantities to simplify the search for a clinically sensible plan. Methods: A permissible dosimetric uncertainty is introduced for each of the structures to balance their conflicting dosimetric requirements. The inverse planning is then formulated as a convex feasibility problem, which aims to generate plans with acceptable dosimetric uncertainties. A sequential procedure (SP) is derived to decompose the model into three submodels to constrain the uncertainty in the planning target volume (PTV), the critical structures, and all other structures to spare, sequentially. The proposed technique is applied to plan a liver case and a head-and-neck case and compared with a conventional approach. Results: Our results show that the strategy is able to generate clinically sensible plans with little trial-and-error. In the case of liver IMRT, the fractional volumes to liver and heart above 20Gy are found to be 22% and 10%, respectively, which are 15.1% and 33.3% lower than that of the counterpart conventional plan while maintaining the same PTV coverage. The planning of the head and neck IMRT show the same level of success, with the DVHs for all organs at risk and PTV very competitive to a counterpart plan. Conclusion: A new inverse planning framework has been established. With physically more meaningful modeling of the inter-structural tradeoff, the technique enables us to substantially reduce the need for trial-and-error adjustment of the model parameters and opens new opportunities of incorporating prior

  10. Dosimetric evaluation of whole-breast radiation therapy: Clinical experience

    International Nuclear Information System (INIS)

    Osei, Ernest; Darko, Johnson; Fleck, Andre; White, Jana; Kiciak, Alexander; Redekop, Rachel; Gopaul, Darin

    2015-01-01

    Radiation therapy of the intact breast is the standard therapy for preventing local recurrence of early-stage breast cancer following breast conservation surgery. To improve patient standard of care, there is a need to define a consistent and transparent treatment path for all patients that reduces significance variations in the acceptability of treatment plans. There is lack of consistency among institutions or individuals about what is considered an acceptable treatment plan: target coverage vis-à-vis dose to organs at risk (OAR). Clinical trials usually resolve these issues, as the criteria for an acceptable plan within the trial (target coverage and doses to OAR) are well defined. We developed an institutional criterion for accepting breast treatment plans in 2006 after analyzing treatment data of approximately 200 patients. The purpose of this article is to report on the dosimetric review of 623 patients treated in the last 18 months to evaluate the effectiveness of the previously developed plan acceptability criteria and any possible changes necessary to further improve patient care. The mean patient age is 61.6 years (range: 25.2 to 93.0 years). The mean breast separation for all the patients is 21.0 cm (range: 12.4 to 34.9 cm), and the mean planning target volume (PTV-eval) (breast volume for evaluation) is 884.0 cm"3 (range: 73.6 to 3684.6 cm"3). Overall, 314 (50.4%) patients had the disease in the left breast and 309 (49.6%) had it in the right breast. A total of 147 (23.6%) patients were treated using the deep inspiration breath-hold (DIBH) technique. The mean normalized PTV-eval receiving at least 92% (V_9_2_% _P_D) and 95% (V_9_5_% _P_D) of the prescribed dose (PD) are more than 99% and 97%, respectively, for all patients. The mean normalized PTV-eval receiving at least 105% (V_1_0_5_% _P_D) of the PD is less than 1% for all groups. The mean homogeneity index (HI), uniformity index (UI), and conformity index (CI) for the PTV-eval are 0.09 (range: 0

  11. Dosimetric analysis of SMD phototransistor in dental phantom of different geometries

    International Nuclear Information System (INIS)

    Belinato, W.; Magalhaes, C. M. S.; Souza, D. N.; Santos, L. A. P.

    2009-10-01

    A commercial surface mount device (SMD) phototransistor, OP520, was inserted in two dental phantoms for dosimetric analysis. The irradiations were accomplished in a dental x-ray equipment of 80 kV using different exposition times. A standard ionization chamber was irradiated at the same conditions and the air kerma measured with it was compared with the electrical charge evaluated by the phototransistor. The results showed satisfactory correspondence among the detectors readings. Moreover, the phototransistor showed up quite sensitively for dental applications, allowing verifying the variations for the different phantoms configurations. (Author)

  12. Monte-Carlo simulation of the SL-ELEKTA-20 medical linear accelerator. Dosimetric study of a water phantom

    International Nuclear Information System (INIS)

    Thiam, Ch. O.

    2003-06-01

    In radiotherapy, it is essential to have a precise knowledge of the dose delivered in the target volume and the neighbouring critical organs. To be usable clinically, the models of calculation must take into account the exact characteristics of the beams used and the densities of fabrics. Today we can use sophisticated irradiation techniques and get a more precise assessment of the dose and with a better knowledge of its distribution. Thus in this report, will be detailed a simulation of the head of irradiation of accelerator SL-ELEKTA-20 in electrons mode and a dosimetric study of a water phantom. This study is carried out with the code of simulation Monte Carlo GATE adapted for applications of medical physics; the results are compared with the data obtained by the anticancer center 'Jean Perrin' on a similar accelerator. (author)

  13. Radiological assessment of depleted uranium migration offsite from an ordnance range

    International Nuclear Information System (INIS)

    Rynders, D.G.

    1996-01-01

    The military utilizes ordnance loaded with depleted uranium in order to maximize armor penetrating capabilities. These weapons are tested on open ranges where the weapons are fired through a cloth target and impact into the soil. This paper examines the potential environmental impact from use of depleted uranium in an open setting. A preliminary pathway analysis was performed to examine potential routes of exposure to nonhuman species in the vicinity and ultimately to man. Generic data was used in the study to estimate the isotopic mix and weight of the ordnance. Key factors in the analysis included analyzing the physics of weapon impact on soil, chemical changes in material upon impact, and mechanisms of offsite transport (including atmospheric and overland transport). Non-standard exposure scenarios were investigated, including the possibility of offsite contaminant transport due to range grassfires. Two radiological assessment codes, MEPAS (Multi media Environmental Pollutant Assessment System) and RESRAD were used to help analyze the scenarios

  14. Determination of trapping parameters of dosimetric thermoluminescent glow peak of lithium triborate (LiB{sub 3}O{sub 5}) activated by aluminum

    Energy Technology Data Exchange (ETDEWEB)

    Kafadar, V. Emir [University of Gaziantep, Department of Engineering Physics, 27310 Gaziantep (Turkey); Yazici, A. Necmeddin, E-mail: yazici@gantep.edu.t [University of Gaziantep, Department of Engineering Physics, 27310 Gaziantep (Turkey); Yildirim, R. Gueler [University of Gaziantep, Department of Engineering Physics, 27310 Gaziantep (Turkey)

    2009-07-15

    Lithium triborate (LBO) is a newly developed ideal nonlinear optical (NLO) crystal used in laser weapon, welder, radar, tracker, surgery, communication, etc. The effective atomic number (Z{sub eff}=7.3) makes it a tissue equivalent material and this encourages studies on its thermoluminescence (TL) properties for a radiation dosimetry. The previous studies have shown that Al-doped LiB{sub 3}O{sub 5} is a promising thermoluminescent dosimetric (TLD) material for dosimetric purposes and continuous and systematic investigations to improve its quality to get ones suited for dosimeter applications are worthy. In the given study, the additive dose (AD), initial rise with partial cleaning (IR), variable heating rate (VHR), peak shape (PS), three-points method (TPM) and computerized glow deconvolution (CGCD) methods were used to determine the kinetic parameters, namely the order of kinetics (b), activation energy (E{sub a}) and the frequency factor (s) associated with the dosimetric thermoluminescent glow peak (P3) of Al-doped LiB{sub 3}O{sub 5} after different dose levels with beta-irradiation.

  15. Poster — Thur Eve — 74: Distributed, asynchronous, reactive dosimetric and outcomes analysis using DICOMautomaton

    International Nuclear Information System (INIS)

    Clark, Haley; Wu, Jonn; Moiseenko, Vitali; Thomas, Steven

    2014-01-01

    Many have speculated about the future of computational technology in clinical radiation oncology. It has been advocated that the next generation of computational infrastructure will improve on the current generation by incorporating richer aspects of automation, more heavily and seamlessly featuring distributed and parallel computation, and providing more flexibility toward aggregate data analysis. In this report we describe how a recently created — but currently existing — analysis framework (DICOMautomaton) incorporates these aspects. DICOMautomaton supports a variety of use cases but is especially suited for dosimetric outcomes correlation analysis, investigation and comparison of radiotherapy treatment efficacy, and dose-volume computation. We describe: how it overcomes computational bottlenecks by distributing workload across a network of machines; how modern, asynchronous computational techniques are used to reduce blocking and avoid unnecessary computation; and how issues of out-of-date data are addressed using reactive programming techniques and data dependency chains. We describe internal architecture of the software and give a detailed demonstration of how DICOMautomaton could be used to search for correlations between dosimetric and outcomes data

  16. Post-pneumonectomy empyema and dosimetric CT scan. Report of two cases and review of literature

    International Nuclear Information System (INIS)

    Latorzeff, I.; Bachaud, J.M.; Aziza, R.; Arboucalot, F.; Berjaud, J.; Dahan, M.; Giron, J.

    1999-01-01

    Following a pneumonectomy for cancer, the patients are classically observed by clinical examination and standard chest X-ray. However, torpid empyemas can be missed when they occur after the period of hospitalization and when they are not accompanied by a fever, At the time of postoperative radiotherapy, the dosimetric CT scan constitutes the first examination providing objective information of the endo-thoracic content. It is therefore necessary on this occasion to assure the normality of the post-pneumonectomy pleural space while checking that the substituted liquid is homogeneous and above all that the internal mediastinal part of the cavity has a concave appearance. If that is not the case, an empyema should be suspected. The diagnosis, confirmed by a cyto-bacteriological examination of the pleural fluid, constitutes a counter-indication of the radiotherapy. We present two cases of post-pneumonectomy pauci-symptomatic empyema which were diagnosed during the course of postoperative radiotherapy when the initial dosimetric CT scan was pathologic and could have allowed an earlier diagnosis. (author)

  17. Dosimetric comparison of intensity-modulated, conformal, and four-field pelvic radiotherapy boost plans for gynecologic cancer: a retrospective planning study

    International Nuclear Information System (INIS)

    Chan, Philip; Yeo, Inhwan; Perkins, Gregory; Fyles, Anthony; Milosevic, Michael

    2006-01-01

    To evaluate intensity-modulated radiation therapy (IMRT) as an alternative to conformal radiotherapy (CRT) or 4-field box boost (4FB) in women with gynecologic malignancies who are unsuitable for brachytherapy for technical or medical reasons. Dosimetric and toxicity information was analyzed for 12 patients with cervical (8), endometrial (2) or vaginal (2) cancer previously treated with external beam pelvic radiotherapy and a CRT boost. Optimized IMRT boost treatment plans were then developed for each of the 12 patients and compared to CRT and 4FB plans. The plans were compared in terms of dose conformality and critical normal tissue avoidance. The median planning target volume (PTV) was 151 cm 3 (range 58–512 cm 3 ). The median overlap of the contoured rectum with the PTV was 15 (1–56) %, and 11 (4–35) % for the bladder. Two of the 12 patients, both with large PTVs and large overlap of the contoured rectum and PTV, developed grade 3 rectal bleeding. The dose conformity was significantly improved with IMRT over CRT and 4FB (p ≤ 0.001 for both). IMRT also yielded an overall improvement in the rectal and bladder dose-volume distributions relative to CRT and 4FB. The volume of rectum that received the highest doses (>66% of the prescription) was reduced by 22% (p < 0.001) with IMRT relative to 4FB, and the bladder volume was reduced by 19% (p < 0.001). This was at the expense of an increase in the volume of these organs receiving doses in the lowest range (<33%). These results indicate that IMRT can improve target coverage and reduce dose to critical structures in gynecologic patients receiving an external beam radiotherapy boost. This dosimetric advantage will be integrated with other patient and treatment-specific factors, particularly internal tumor movement during fractionated radiotherapy, in the context of a future image-guided radiation therapy study

  18. SU-F-T-189: Dosimetric Comparison of Spot-Scanning Proton Therapy Techniques for Liver Tumors Close to the Skin Surface

    International Nuclear Information System (INIS)

    Takao, S; Matsuzaki, Y; Matsuura, T; Umegaki, K; Fujii, Y; Fujii, T; Katoh, N; Shimizu, S; Shirato, H

    2016-01-01

    Purpose: Spot-scanning technique has been utilized to achieve conformal dose distribution to large and complicated tumors. This technique generally does not require patient-specific devices such as aperture and compensator. The commercially available spot-scanning proton therapy (SSPT) systems, however, cannot deliver proton beams to the region shallower than 4 g/cm2. Therefore some range compensation device is required to treat superficial tumors with SSPT. This study shows dosimetric comparison of the following treatment techniques: (i) with a tabletop bolus, (ii) with a nozzle-mounted applicator, and (iii) without any devices and using intensity-modulated proton therapy (IMPT) technique. Methods: The applicator composed of a combination of a mini-ridge filter and a range shifter has been manufactured by Hitachi, Ltd., and the tabletop bolus was made by .decimal, Inc. Both devices have been clinically implemented in our facility. Three patients with liver tumors close to the skin surface were examined in this study. Each treatment plan was optimized so that the prescription dose of 76 Gy(RBE) or 66 Gy(RBE) would be delivered to 99% of the clinical target volume in 20 fractions. Three beams were used for tabletop bolus plan and IMPT plan, whereas two beams were used in the applicator plan because the gantry angle available was limited due to potential collision to patient and couch. The normal liver, colon, and skin were considered as organs at risk (OARs). Results: The target heterogeneity index (HI = D_5/D_9_5) was 1.03 on average in each planning technique. The mean dose to the normal liver was considerably less than 20 Gy(RBE) in all cases. The dose to the skin could be reduced by 20 Gy(RBE) on average in the IMPT plan compared to the applicator plan. Conclusion: It has been confirmed that all treatment techniques met the dosimetric criteria for the OARs and could be implemented clinically.

  19. SU-F-T-189: Dosimetric Comparison of Spot-Scanning Proton Therapy Techniques for Liver Tumors Close to the Skin Surface

    Energy Technology Data Exchange (ETDEWEB)

    Takao, S; Matsuzaki, Y [Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Hokkaido (Japan); Matsuura, T; Umegaki, K [Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido (Japan); Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Hokkaido (Japan); Fujii, Y; Fujii, T [Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido (Japan); Katoh, N [Department of Radiation Oncology, Hokkaido University Hospital, Sapporo, Hokkaido (Japan); Shimizu, S; Shirato, H [Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Hokkaido (Japan); Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido (Japan)

    2016-06-15

    Purpose: Spot-scanning technique has been utilized to achieve conformal dose distribution to large and complicated tumors. This technique generally does not require patient-specific devices such as aperture and compensator. The commercially available spot-scanning proton therapy (SSPT) systems, however, cannot deliver proton beams to the region shallower than 4 g/cm2. Therefore some range compensation device is required to treat superficial tumors with SSPT. This study shows dosimetric comparison of the following treatment techniques: (i) with a tabletop bolus, (ii) with a nozzle-mounted applicator, and (iii) without any devices and using intensity-modulated proton therapy (IMPT) technique. Methods: The applicator composed of a combination of a mini-ridge filter and a range shifter has been manufactured by Hitachi, Ltd., and the tabletop bolus was made by .decimal, Inc. Both devices have been clinically implemented in our facility. Three patients with liver tumors close to the skin surface were examined in this study. Each treatment plan was optimized so that the prescription dose of 76 Gy(RBE) or 66 Gy(RBE) would be delivered to 99% of the clinical target volume in 20 fractions. Three beams were used for tabletop bolus plan and IMPT plan, whereas two beams were used in the applicator plan because the gantry angle available was limited due to potential collision to patient and couch. The normal liver, colon, and skin were considered as organs at risk (OARs). Results: The target heterogeneity index (HI = D{sub 5}/D{sub 95}) was 1.03 on average in each planning technique. The mean dose to the normal liver was considerably less than 20 Gy(RBE) in all cases. The dose to the skin could be reduced by 20 Gy(RBE) on average in the IMPT plan compared to the applicator plan. Conclusion: It has been confirmed that all treatment techniques met the dosimetric criteria for the OARs and could be implemented clinically.

  20. Chilean Nuclear Energy Commission dosimetric information system

    International Nuclear Information System (INIS)

    Guerrero Vallejos, Patricia Andrea

    1997-01-01

    This thesis discusses the nuclear radiation that people who work with radioactive material is exposed to and its control by the Chilean Nuclear Energy Commission. A full analysis of the System is presented with information about the Commission and the Department of Nuclear and Radiological Safety which runs the System. Ana analysis of the System is presented in order to obtain requirements. Management flow diagrams, the processes involved and current problems experienced by the users are described. A design logic is modeled producing Data Flow Diagrams (DFD). based on this physical design, or, Model of Physical Data, is prepared including tables, attributes, types of data, primary and foreign keys. A description is presented of how the System is implemented, the tools that are used and how the testing phase is carried out. The Dosimetry System meets the criteria for a Software Engineering project, where the basic cycle was used as a working methodology. The System developed supports the dosimetric control of people exposed to radioactive material. (author)

  1. Dosimetric evaluation program for dental radiology practices

    International Nuclear Information System (INIS)

    Gregori, B.; Milat, J.; Fernandez, J.; Micinquevich, S.; Andrieu, J.

    1992-01-01

    The preliminary results of a program undertaken to estimate the doses to patients associated with dental radiology practices in Argentine, are presented. Information collected from the search demonstrated that the Dieck and coronal techniques are the most commonly used practices, while all the examinations are performed by using a circular collimator. For both practices, the dosimetric studies were carried out on a Rando Alderson phantom. All dose measurements were made using thermoluminescent detectors LiF and Ca 2 F. In addition, a mathematical model was developed by applying the Monte Carlo method to a MIRD-V phantom. Circular and rectangular collimators were used. Absorbed dose distribution on head and neck, as well as surface dose distribution, were estimated. The comparison of the performance of both collimators shows that the use of the rectangular one allows for a dose reduction of 80%. Besides, a good correlation between the physical and mathematical models applied was found. (author)

  2. Assessment of cervical range of motion, cervical core strength and scapular dyskinesia in violin players.

    Science.gov (United States)

    Tawde, Pooja; Dabadghav, Rachana; Bedekar, Nilima; Shyam, Ashok; Sancheti, Parag

    2016-12-01

    Playing the violin can lead to asymmetric postures which can affect the cervical range of motion, cervical core strength and scapular stability. The objective of the study was to assess the cervical range of motion, cervical core strength and scapular dyskinesia in violin players and non-players of the same age group. An inclinometer was used to assess the cervical range of motion, pressure biofeedback was used to assess cervical core strength and scapular dyskinesia was also assessed in 30 professional violin players (18-40 years) compared with 30 age-matched non-players. Analysis was done using an unpaired t test. Significant change was seen with respect to extension (p = 0.051), cervical core strength (p = 0.005), right (Rt) superior angle 0° (p = 0.004), Rt superior angle 45° (p = 0.015) and Rt inferior angle 90° (p = 0.013). This study shows a significant difference in extension range of motion and cervical core strength of violin players. Also, there was scapular dyskinesia seen at 0° and 45° right-side superior angle of the scapula and 90° right-side inferior angle of the scapula.

  3. Development of a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value; Erarbeitung eines Konzepts zur Ermittlung der Strahlenexposition von Patienten bei zahnmedizinischen Roentgenuntersuchungen und Erhebung von statistischen Daten zur Erstellung diagnostischer Referenzwerten

    Energy Technology Data Exchange (ETDEWEB)

    Kueppers, C.; Sering, M. [Oekoinstitut Freiburg e.V., Freiburg (Germany); Poppe, B.; Poplawski, A.; Looe, H.K.; Beyer, D.; Pfaffenberger, A.; Chofor, N.; Eenboom, F. [Pius Hospital, Oldenburg (Germany)

    2012-02-15

    The research project on the development a concept for radiation patients exposure assessment during dental X-ray examinations and statistical data acquisition for the determination of a diagnostic reference value includes the following issues: Fundamental facts: dental X-ray examination techniques, dose relevant factors and characteristics during X-ray examinations, radiation exposed organs during dental X-ray examinations, dose assessment based on phantoms. Materials and methodologies of the project: TLD measurements using the phantom, calculation of the effective dose during dental X-ray examinations, properties and settings of the reference facilities for the determination of radiation exposure, selection of dental offices, dosimetric measurements, data acquisition and statistical evaluation. Results of dosimetric examinations: results of dosimetric measurements at reference facilities, results of dosimetric measurements in dental offices. Discussion of the concept for the determination of the radiation exposure during dental X-ray examinations.

  4. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-01-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al 2 O 3 :C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al 2 O 3 :C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O 3 :C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  5. New routes of preparation of polyaniline films and dosimetric characterization for high-doses gamma radiation; Novas rotas de preparacao de filmes de polianilina e caracterizacao dosimetrica para radiacao gama em altas doses

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Ana Paula Lima

    2003-08-15

    This work presents a new conducting polymeric material based on polyaniline thin films that will be used in the confection of dosimetric devices. On preparation of the films a homogeneous and viscous solution of poly (acrylic acid) and MnO{sub 2} is deposited on PMMA surface, which after dried, is immersed in an acid aniline solution. The films formed present low resistivity (6.10{sup 2} {omega}m), good mechanical resistance and adherence on the electrodes. The films were characterized by infrared spectroscopy, conductivity measurements and manganese elemental analyses. The resistance variations show linear correlation (r{sup 2} = 0,9928) with gamma irradiation dose in the range of 1000 to 6000 Gy, with medium error less than 5% and sensitivity response. The dosimetric devices present as advantage real time measurements, low cost, use in calibration of industrial radioactive sources. Moreover, this composite could in future replace Fricke dosimeter and its applications. A calibration curve is showed for PANI dosimeter, here proposed, to use at high gamma doses. (author)

  6. Dosimetric of extremities with Dosemeters thermoluminescent in Cuba

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Vera Alonso, L.

    1998-01-01

    From final of the year 1995 in the CPHR implement the service of monitoring of the extremities using Dosemeter thermoluminescent (TL). The dosemeter consists on a metallic ring with a circular hole where a detector of LiF:Mg,Ti is placed (model JR1152C) of 5x5x0.9 mm 3 , covered by a fine layer of polyethylene. In the work the characteristic dosimetric as of the dosemeter is studied it satisfies the main requirements for their use in the monitoring from the exhibition to radiation photonic of the extremities. The doses are also presented registered during the first two years of operation of the service. The results obtained until the moment point out to you practice them of nuclear medicine, radiotherapy and production of substances radioactive how as of more contribution

  7. Clinical and dosimetric predictors of acute hematologic toxicity in rectal cancer patients undergoing chemoradiotherapy

    International Nuclear Information System (INIS)

    Yang, T. Jonathan; Oh, Jung Hun; Apte, Aditya; Son, Christina H.; Deasy, Joseph O.; Goodman, Karyn A.

    2014-01-01

    Background and purpose: To identify clinical and dosimetric factors associated with hematologic toxicity (HT) during chemoradiotherapy for rectal cancer. Materials and methods: We analyzed 120 rectal cancer patients treated with neoadjuvant pelvic radiotherapy (PRT) with concurrent 5-fluorouracil-based chemotherapy. The coxal (ilium, ischium, and pubis) bone marrow (BM), sacral BM, and femoral BM were contoured and dose-volume parameters were extracted. Associations between cell count trend and clinical predictors were tested using repeated-measures analysis of variance (ANOVA) test. Associations between clinical variables, Vx (percentage volume receiving x Gy), and cell count ratio at nadir were tested using linear regression models. Results: Nadirs for white blood cell count (WBC), absolute neutrophil count (ANC), and platelets (PLT) occurred in the second week of PRT and the fifth week for hemoglobin and absolute lymphocyte count (ALC). Using cell count ratio, patients treated with 3DCRT had a lower WBC ratio trend during PRT compared to patients treated with IMRT (p = 0.04), and patients ⩾59 years of age had a lower hemoglobin ratio trend during PRT (p = 0.02). Using absolute cell count, patients treated with 3DCRT had lower ANC cell count trend (p = 0.03), and women had lower hemoglobin cell count trend compared to men (p = 0.03). On univariate analysis, use of 3DCRT was associated with a lower WBC ratio at nadir (p = 0.02). On multiple regression analysis using dosimetric variables, coxal BM V45 (p = 0.03) and sacral BM V45 (p = 0.03) were associated with a lower WBC and ANC ratio at nadir, respectively. Conclusions: HT trends during PRT revealed distinct patterns: WBC, ANC, and PLT cell counts reach nadirs early and recover, while hemoglobin and ALC decline steadily. Patients who were treated with 3DCRT and older patients experienced lower cell count ratio trend during PRT. Dosimetric constraints using coxal BM V45 and sacral BM V45 can be considered

  8. Determination of Dosimetric Parameters of the Second Model of Pd-103 Seed Manufactured at Agricultural, Medical and Industrial Research School

    Directory of Open Access Journals (Sweden)

    Gholamreza Raisali

    2008-06-01

    Full Text Available Introduction: The use of low energy isotopes such as  103 Pd in brachytherapy for the treatment of cancers  such as prostate, eye, head, neck, breast and cervix is increasing. In this regard, different models of Pd- 103  seeds  have  been  designed  and  manufactured  at  the  Agricultural,  Medical  and  Industrial  Research  School (AMIRS of Atomic Energy Organization of Iran. In this research, the dosimetric parameters of  the second model of Pd-103 seed manufactured at AMIRS have been calculated and measured.   Materials and Methods: The dosimetric parameters of the second Pd-103 seed manufactured at AMIRS  were determined according to TG-43U1 protocol using Monte Carlo calculations (MCNP4C computer  code  and  measurements  performed  using  TLD-GR200A  dosimeters  in  a  Perspex  phantom.  The  parameters  include  dose  rate  constant,  geometry  function,  radial  dose  function,  anisotropy  function,  anisotropy factor and anisotropy constant.  Results:  It  was  found  that  by  using  MCNP4C  code  the  calculated  dose  rate  constant  in  water  and  Perspex  was  0.706±0.001   and  0.501±0.001  cGyh -1 U -1 , respectively.  Using  the  calculated  geometry  function,  the  radial  dose  function  and  the  anisotropy  function  were  determined  by  experimental  and  theoretical methods in water and Perspex phantom. Also, the calculated value of anisotropy constant in  water was equal to 0.88.  Discussion and Conclusion: A discrepancy of less than 10% between the calculated and the measured  values indicates a reasonable agreement between the simulation and the measurement method. Also, the  dosimetric parameters of this seed have been compared to the dosimetric parameters of the first Pd-103  seed  manufactured  at  AMIRS  and  some  other  seeds.  The  obtained  results  indicate  that  the  seeds  manufactured at AMIRS

  9. Natural phenomena risk assessment at Rocky Flats Plant

    International Nuclear Information System (INIS)

    Foppe, T.L.

    1985-01-01

    A realistic approach is currently being used at the Rocky Flats Plant to assess the risks of natural phenomena events. The methodology addresses frequency of occurrence estimates, damage stress on the facility and vital equipment, material-at-risk, release fractions and source terms, leakpath, dispersion and dosimetric models, risk curves, and an uncertainty analysis. 28 references, 1 figure

  10. Dosimetric Feasibility of Hypofractionated Proton Radiotherapy for Neoadjuvant Pancreatic Cancer Treatment

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Kachnic, Lisa A.; Adams, Judith C; Crowley, Elizabeth M.; Alexander, Brian M.; Mamon, Harvey J.; Fernandez-Del Castillo, Carlos; Ryan, David P.; DeLaney, Thomas F.; Hong, Theodore S.

    2007-01-01

    Purpose: To evaluate tumor and normal tissue dosimetry of a 5 cobalt gray equivalent (CGE) x 5 fraction proton radiotherapy schedule, before initiating a clinical trial of neoadjuvant, short-course proton radiotherapy for pancreatic adenocarcinoma. Methods and Materials: The first 9 pancreatic cancer patients treated with neoadjuvant intensity-modulated radiotherapy (1.8 Gy x 28) at the Massachusetts General Hospital had treatment plans generated using a 5 CGE x 5 fraction proton regimen. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Hypofractionated proton and conventionally fractionated intensity-modulated radiotherapy plans both provided acceptable target volume coverage and dose homogeneity. Improved dose conformality provided by the hypofractionated proton regimen resulted in significant sparing of kidneys, liver, and small bowel, evidenced by significant reductions in the mean doses, expressed as percentage prescribed dose, to these structures. Kidney and liver sparing was most evident in low-dose regions (≤20% prescribed dose for both kidneys and ≤60% prescribed dose for liver). Improvements in small-bowel dosimetry were observed in high- and low-dose regions. Mean stomach and duodenum doses, expressed as percentage prescribed dose, were similar for the two techniques. Conclusions: A proton radiotherapy schedule consisting of 5 fractions of 5 CGE as part of neoadjuvant therapy for adenocarcinoma of the pancreas seems dosimetrically feasible, providing excellent target volume coverage, dose homogeneity, and normal tissue sparing. Hypofractionated proton radiotherapy in this setting merits Phase I clinical trial investigation

  11. Brachial Plexopathy in Apical Non-Small Cell Lung Cancer Treated With Definitive Radiation: Dosimetric Analysis and Clinical Implications

    International Nuclear Information System (INIS)

    Eblan, Michael J.; Corradetti, Michael N.; Lukens, J. Nicholas; Xanthopoulos, Eric; Mitra, Nandita; Christodouleas, John P.; Grover, Surbhi; Fernandes, Annemarie T.; Langer, Corey J.; Evans, Tracey L.; Stevenson, James; Rengan, Ramesh; Apisarnthanarax, Smith

    2013-01-01

    Purpose: Data are limited on the clinical significance of brachial plexopathy in patients with apical non-small cell lung cancers (NSCLC) treated with definitive radiation therapy. We report the rates of radiation-induced brachial plexopathy (RIBP) and tumor-related brachial plexopathy (TRBP) and associated dosimetric parameters in apical NSCLC patients. Methods and Materials: Charts of NSCLC patients with primary upper lobe or superiorly located nodal disease who received ≥50 Gy of definitive conventionally fractionated radiation or chemoradiation were retrospectively reviewed for evidence of brachial plexopathy and categorized as RIBP, TRBP, or trauma-related. Dosimetric data were gathered on ipsilateral brachial plexuses (IBP) contoured according to Radiation Therapy Oncology Group atlas guidelines. Results: Eighty patients were identified with a median follow-up and survival time of 17.2 and 17.7 months, respectively. The median prescribed dose was 66.6 Gy (range, 50.4-84.0), and 71% of patients received concurrent chemotherapy. RIBP occurred in 5 patients with an estimated 3-year rate of 12% when accounting for competing risk of death. Seven patients developed TRBP (estimated 3-year rate of 13%), comprising 24% of patients who developed locoregional failures. Grade 3 brachial plexopathy was more common in patients who experienced TRBP than RIBP (57% vs 20%). No patient who received ≤78 Gy to the IBP developed RIBP. On multivariable competing risk analysis, IBP V76 receiving ≥1 cc, and primary tumor failure had the highest hazard ratios for developing RIBP and TRBP, respectively. Conclusions: RIBP is a relatively uncommon complication in patients with apical NSCLC tumors receiving definitive doses of radiation, while patients who develop primary tumor failures are at high risk for developing morbid TRBP. These findings suggest that the importance of primary tumor control with adequate doses of radiation outweigh the risk of RIBP in this population of

  12. Dosimetric aspects of radiation processing of food and allied products

    International Nuclear Information System (INIS)

    Sharma, G.; Bhat, R.M.; Bhatt, B.C.

    2010-01-01

    Full text: Gamma radiation processing in the last 4-5 decades is continuously gaining importance in processing of a wide variety of products, as it can modify physical, chemical and biological properties of the materials, including food and allied products on industrial scale due its inherent qualities like ease of processing in finally packaged form, eco-friendly nature and other obvious reasons over conventional means of processing. Food and allied products are either from agricultural produce or animal origin; they get easily contaminated from soil during harvesting, handling, processing, environment conditions, storage and transport from various types of micro-organisms including pathogens. In many countries it is mandatory to bring down the population of micro-organisms to an acceptable level and complete elimination of pathogens before such products are accepted for human or animal consumption. Processing of food and allied products by radiation has its own challenges due to wider public acceptance of irradiated food, a wide range, 0.25-50kGy, of absorbed dose requirements for different category of such products and purposes, use of a variety of packaging materials in different shapes and sizes and because of its perishable nature. More than 50 countries including India in the world have accepted radiation processing of food and allied products by radiation. Dosimetry is an important aspect of radiation processing, whether it is food or allied product. Uniformity in dose delivered to these products depends on several factors such as product carrier to source frame alignment, product carrier and product/tote box design, product loading pattern, attenuation due to product thickness, product bulk density that varies from 0.1-1.0 kg/l and the plant design whether during processing product overlaps the source or otherwise. In this presentation dosimetric aspects of radiation processing of food and allied products and problems associated with dosimetry of such

  13. Methods for calculating dose conversion coefficients for terrestrial and aquatic biota

    International Nuclear Information System (INIS)

    Ulanovsky, A.; Proehl, G.; Gomez-Ros, J.M.

    2008-01-01

    Plants and animals may be exposed to ionizing radiation from radionuclides in the environment. This paper describes the underlying data and assumptions to assess doses to biota due to internal and external exposure for a wide range of masses and shapes living in various habitats. A dosimetric module is implemented which is a user-friendly and flexible possibility to assess dose conversion coefficients for aquatic and terrestrial biota. The dose conversion coefficients have been derived for internal and various external exposure scenarios. The dosimetric model is linked to radionuclide decay and emission database, compatible with the ICRP Publication 38, thus providing a capability to compute dose conversion coefficients for any nuclide from the database and its daughter nuclides. The dosimetric module has been integrated into the ERICA Tool, but it can also be used as a stand-alone version

  14. Quantification of the validity of simulations based on Geant4 and FLUKA for photo-nuclear interactions in the high energy range

    Science.gov (United States)

    Quintieri, Lina; Pia, Maria Grazia; Augelli, Mauro; Saracco, Paolo; Capogni, Marco; Guarnieri, Guido

    2017-09-01

    Photo-nuclear interactions are relevant in many research fields of both fundamental and applied physics and, for this reason, accurate Monte Carlo simulations of photo-nuclear interactions can provide a valuable and indispensable support in a wide range of applications (i.e from the optimisation of photo-neutron source target to the dosimetric estimation in high energy accelerator, etc). Unfortunately, few experimental photo-nuclear data are available above 100 MeV, so that, in the high energy range (from hundreds of MeV up to GeV scale), the code predictions are based on physical models. The aim of this work is to compare the predictions of relevant observables involving photon-nuclear interaction modelling, obtained with GEANT4 and FLUKA, to experimental data (if available), in order to assess the code estimation reliability, over a wide energy range. In particular, the comparison of the estimated photo-neutron yields and energy spectra with the experimental results of the n@BTF experiment (carried out at the Beam Test Facility of DaΦne collider, in Frascati, Italy) is here reported and discussed. Moreover, the preliminary results of the comparison of the cross sections used in the codes with the"evaluated' data recommended by the IAEA are also presented for some selected cases (W, Pb, Zn).

  15. The dependence of prostate postimplant dosimetric quality on CT volume determination

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Dorsey, Anthony T.; Lief, Jonathan H.

    1999-01-01

    Purpose: The postoperative evaluation of permanent prostate brachytherapy requires a subjective determination of the implant volume. This work investigates the magnitude of the effect that various methods of treatment volume delineation have on dosimetric quality parameters for a treatment planning philosophy that defines a target volume as the prostate with a periprostatic margin. Methods and Materials: Eight consecutive prostate brachytherapy patients with a prescribed dose of 145 Gy from 125 I as monotherapy comprised the study population. The prostate ultrasound volume was enlarged to a planning volume by an average factor of 1.8 to encompass probable extracapsular extension in the periprostatic region. For this cohort, the mean pretreatment parameters were 30.3 cm 3 ultrasound volume, 51.8 cm 3 planning volume, 131 seeds per patient, and 42.9 mCi total activity. On CT study sets obtained less than 2 hours postoperatively, target volumes were drawn using three methods: prostate plus a periprostatic margin, prostate only which excluded the puborectalis muscles, the periprostatic fat and the periprostatic venous plexus, and the preplanning ultrasound magnified to conform to the magnification factor of the postimplant CT scan. Three sets of 5 dosimetric quality parameters corresponding to the different volumetric approaches were calculated: V100, V150, and V200 which are the fractions of the target volume covered by 100, 150, and 200% of the prescribed dose, and D90 and D100, which are the minimal doses covering 90 and 100% of the target volume. Results: The postoperative CT volume utilizing the prostate plus margin technique was comparable to the initial planning volume (mean 55.5 cm 3 vs. 51.8 cm 3 , respectively) whereas those determined via superimposing the preplan ultrasound resulted in volumes nearly identical to the initial ultrasound evaluation (mean 32.4 cm 3 vs. 30.3 cm 3 ). The prostate only approach resulted in volumes approximately 25% larger than

  16. SU-D-17A-01: Geometric and Dosimetric Evaluation of a 4D-CBCT Reconstruction Technique Using Prior Knowledge

    International Nuclear Information System (INIS)

    Zhang, Y; Yin, F; Ren, L

    2014-01-01

    Purpose: To evaluate a 4D-CBCT reconstruction technique both geometrically and dosimetrically Methods: A prior-knowledge guided 4DC-BCT reconstruction method named the motion-modeling and free-form deformation (MM-FD) has been developed. MM-FD views each phase of the 4D-CBCT as a deformation of a prior CT volume. The deformation field is first solved by principal component analysis based motion modeling, followed by constrained free-form deformation.The 4D digital extended-cardiac- torso (XCAT) phantom was used for comprehensive evaluation. Based on a simulated 4D planning CT of a lung patient, 8 different scenarios were simulated to cover the typical on-board anatomical and respiratory variations: (1) synchronized and (2) unsynchronized motion amplitude change for body and tumor; tumor (3) shrinkage and (4) expansion; tumor average position shift in (5) superior-inferior (SI) direction, (6) anterior-posterior (AP) direction and (7) SI, AP and lateral directions altogether; and (8) tumor phase shift relative to the respiratory cycle of the body. Orthogonal-view 30° projections were simulated based on the eight patient scenarios to reconstruct on-board 4D-CBCTs. For geometric evaluation, the volume-percentage-difference (VPD) was calculated to assess the volumetric differences between the reconstructed and the ground-truth tumor.For dosimetric evaluation, a gated treatment plan was designed for the prior 4D-CT. The dose distributions were calculated on the reconstructed 4D-CBCTs and the ground-truth images for comparison. The MM-FD technique was compared with MM-only and FD-only techniques. Results: The average (±s.d.) VPD values of reconstructed tumors for MM-only, FDonly and MM-FD methods were 59.16%(± 26.66%), 75.98%(± 27.21%) and 5.22%(± 2.12%), respectively. The average min/max/mean dose (normalized to prescription) of the reconstructed tumors by MM-only, FD-only, MM-FD methods and ground-truth tumors were 78.0%/122.2%/108.2%, 13%/117.7%/86%, 58

  17. Dosimetric study for characterization of a postal system of quality control in brachytherapy; Estudo dosimetrico para caracterizacao de um sistema postal de controle de qualidade em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Victor Gabriel Leandro, E-mail: vgalves@inca.gov.b [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil); Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza, E-mail: queiroz@ird.gov.b, E-mail: santosd@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Begalli, Marcia, E-mail: begalli@uerj.b [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica

    2009-07-01

    This work presents a dosimetric study of a postal system, to be developed for measurements of brachytherapy. It was projected a PMMA phantom with orifices for insertion of the high dose {sup 192}Ir source and the T L dosemeters. The system was characterized with using of Monte Carlo simulations, using the dosimetric magnitudes defined at the T G-43 of AAPM, as function of radial dose g(f)

  18. SU-F-T-45: Dosimetric Effects of Saline Filled Balloons During IORT Using Xoft Electronic Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Redler, G; Templeton, A; Turian, J; Chu, J; Bernard, D; Zhen, H; Liao, Y [Rush University Medical Center, Chicago, IL (United States)

    2016-06-15

    Purpose: The portability of Xoft Axxent Electronic Brachytherapy (EBx) System has made it a viable option for intraoperative radiation therapy (IORT) treatment of early-stage breast cancer. The low energy (50kVp) of the X-ray source makes the shielding easy, but also means its dose distribution is sensitive to the medium’s composition. Current treatment planning systems (TPS) typically assume homogenous water for brachytherapy dose calculations, including the pre-calculated atlas plans for the Xoft IORT cases. However, Xoft recommends using saline to fill the balloon applicator. This study investigates the dosimetric difference due to the increased effective atomic number (Zeff) from water (7.42) to saline (7.56). Methods: The diameter of the balloon applicators ranges from 3–6cm, with 4cm being most frequently used. For the 4-cm and 6-cm diameter applicators, MCNP Monte Carlo program was used to calculate the dose at the surface (Ds) of the middle section of the balloon and 1 cm away (D1cm) for water- and saline-filled balloons: one plan with a single dwell at the center and another with multiple dwells as in the atlas plans. The single dwell plan is a simple estimation of the dosimetry, while the atlas plan is representative of the actual dose distribution. Results: The single-dwell plan showed a 5.1% and 6.1% decrease in Ds for the 4- and 6-cm applicators, respectively, due to the saline. The atlas plan showed similar Results: 4.8% and 6.4% decrease, respectively. The decrease in D1cm is 4.3%–5.2% and 3.3%–5.3s% in the single-dwell and atlas plans, respectively, for the 4- and 6-cm applicator. Conclusion: The dosimetric effect introduced by saline is on the order of 5%. This effect should be taken into account during both treatment planning and patient outcome studies.

  19. Historical accounts of the radiation protection- Dosimetric surveillance of L. Berard Center personnel from 1960 to 1988

    International Nuclear Information System (INIS)

    Paoletti, H.

    1990-09-01

    In this thesis, the author describes the discovery of radiations, their first medical applications and first accidents that have been in the beginning of radiation protection and of its development. The author explains how the dosimetric monitoring has been organized at L. Berard Centre in Lyon (France)

  20. Dosimetric results in treatments of neuroblastoma and neuroendocrine tumors with {sup 131}I-metaiodobenzylguanidine with implications for the activity to administer

    Energy Technology Data Exchange (ETDEWEB)

    Mínguez, Pablo, E-mail: pablo.minguezgabina@osakidetza.net [Department of Medical Radiation Physics, Lund University, Lund 22185, Sweden and Department of Medical Physics, Gurutzeta/Cruces University Hospital, Barakaldo 48903 (Spain); Flux, Glenn [Joint Department of Physics, Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Sutton SM2 5PT (United Kingdom); Genollá, José; Guayambuco, Sonía; Delgado, Alejandro; Fombellida, José Cruz [Department of Nuclear Medicine, Gurutzeta/Cruces University Hospital, Barakaldo 48903 (Spain); Sjögreen Gleisner, Katarina [Department of Medical Radiation Physics, Lund University, Lund 22185 (Sweden)

    2015-07-15

    Purpose: The aim was to investigate whole-body and red marrow absorbed doses in treatments of neuroblastoma (NB) and adult neuroendocrine tumors (NETs) with {sup 131}I-metaiodobenzylguanidine and to propose a simple method for determining the activity to administer when dosimetric data for the individual patient are not available. Methods: Nine NB patients and six NET patients were included, giving in total 19 treatments as four patients were treated twice. Whole-body absorbed doses were determined from dose-rate measurements and planar gamma-camera imaging. For six NB and five NET treatments, red marrow absorbed doses were also determined using the blood-based method. Results: Dosimetric data from repeated administrations in the same patient were consistent. In groups of NB and NET patients, similar whole-body residence times were obtained, implying that whole-body absorbed dose per unit of administered activity could be reasonably well described as a power function of the patient mass. For NB, this functional form was found to be consistent with dosimetric data from previously published studies. The whole-body to red marrow absorbed dose ratio was similar among patients, with values of 1.4 ± 0.6–1.7 ± 0.7 (1 standard deviation) in NB treatments and between 1.5 ± 0.6 and 1.7 ± 0.7 (1 standard deviation) in NET treatments. Conclusions: The consistency of dosimetric results between administrations for the same patient supports prescription of the activity based on dosimetry performed in pretreatment studies, or during the first administration in a fractionated schedule. The expressions obtained for whole-body absorbed doses per unit of administered activity as a function of patient mass for NB and NET treatments are believed to be a useful tool to estimate the activity to administer at the stage when the individual patient biokinetics has not yet been measured.

  1. Dosimetric comparison between intensity modulated brachytherapy versus external beam intensity modulated radiotherapy for cervix cancer: a treatment planning study

    International Nuclear Information System (INIS)

    Subramani, V.; Sharma, D.N.; Jothy Basu, K.S.; Rath, G.K.; Gopishankar, N.

    2008-01-01

    To evaluate the dosimetric superiority of intensity modulated brachytherapy (IMBT) based on inverse planning optimization technique with classical brachytherapy optimization and also with external beam intensity modulated radiotherapy planning technique in patients of cervical carcinoma

  2. Analysis of clinical and dosimetric factors associated with treatment-related pneumonitis (TRP) in patients with non-small-cell lung cancer (NSCLC) treated with concurrent chemotherapy and three-dimensional conformal radiotherapy (3D-CRT)

    International Nuclear Information System (INIS)

    Wang Shulian; Liao Zhongxing; Wei Xiong; Liu, Helen H.; Tucker, Susan L.; Hu Chaosu; Mohan, Rodhe; Cox, James D.; Komaki, Ritsuko

    2006-01-01

    Purpose: To investigate factors associated with treatment-related pneumonitis in non-small-cell lung cancer patients treated with concurrent chemoradiotherapy. Patients and Methods: We retrospectively analyzed data from 223 patients treated with definitive concurrent chemoradiotherapy. Treatment-related pneumonitis was graded according to Common Terminology Criteria for Adverse Events version 3.0. Univariate and multivariate analyses were performed to identify predictive factors. Results: Median follow-up was 10.5 months (range, 1.4-58 months). The actuarial incidence of Grade ≥3 pneumonitis was 22% at 6 months and 32% at 1 year. By univariate analyses, lung volume, gross tumor volume, mean lung dose, and relative V5 through V65, in increments of 5 Gy, were all found to be significantly associated with treatment-related pneumonitis. The mean lung dose and rV5-rV65 were highly correlated (p 42% were 3% and 38%, respectively (p = 0.001). Conclusions: In this study, a number of clinical and dosimetric factors were found to be significantly associated with treatment-related pneumonitis. However, rV5 was the only significant factor associated with this toxicity. Until it is better understood which dose range is most relevant, multiple clinical and dosimetric factors should be considered in treatment planning for non-small-cell lung cancer patients receiving concurrent chemoradiotherapy

  3. Analysis of Dosimetric Parameters Associated With Acute Gastrointestinal Toxicity and Upper Gastrointestinal Bleeding in Locally Advanced Pancreatic Cancer Patients Treated With Gemcitabine-Based Concurrent Chemoradiotherapy

    International Nuclear Information System (INIS)

    Nakamura, Akira; Shibuya, Keiko; Matsuo, Yukinori; Nakamura, Mitsuhiro; Shiinoki, Takehiro; Mizowaki, Takashi; Hiraoka, Masahiro

    2012-01-01

    Purpose: To identify the dosimetric parameters associated with gastrointestinal (GI) toxicity in patients with locally advanced pancreatic cancer (LAPC) treated with gemcitabine-based chemoradiotherapy. Methods and Materials: The data from 40 patients were analyzed retrospectively. Chemoradiotherapy consisted of conventional fractionated three-dimensional radiotherapy and weekly gemcitabine. Treatment-related acute GI toxicity and upper GI bleeding (UGB) were graded according to the Common Toxicity Criteria Adverse Events, version 4.0. The dosimetric parameters (mean dose, maximal absolute dose which covers 2 cm 3 of the organ, and absolute volume receiving 10–50 Gy [V 10–50 ]) of the stomach, duodenum, small intestine, and a composite structure of the stomach and duodenum (StoDuo) were obtained. The planning target volume was also obtained. Univariate analyses were performed to identify the predictive factors for the risk of grade 2 or greater acute GI toxicity and grade 3 or greater UGB, respectively. Results: The median follow-up period was 15.7 months (range, 4–37). The actual incidence of acute GI toxicity was 33%. The estimated incidence of UGB at 1 year was 20%. Regarding acute GI toxicity, a V 50 of ≥16 cm 3 of the stomach was the best predictor, and the actual incidence in patients with V 50 3 of the stomach vs. those with V 50 of ≥16 cm 3 was 9% vs. 61%, respectively (p = 0.001). Regarding UGB, V 50 of ≥33 cm 3 of the StoDuo was the best predictor, and the estimated incidence at 1 year in patients with V 50 3 of the StoDuo vs. those with V 50 ≥33 cm 3 was 0% vs. 44%, respectively (p = 0.002). The dosimetric parameters correlated highly with one another. Conclusion: The irradiated absolute volume of the stomach and duodenum are important for the risk of acute GI toxicity and UGB. These results could be helpful in escalating the radiation doses using novel techniques, such as intensity-modulated radiotherapy, for the treatment of pancreatic

  4. Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT

    International Nuclear Information System (INIS)

    Srivastava, Shiv P.; Das, Indra J.; Kumar, Arvind; Johnstone, Peter A.S.

    2011-01-01

    Dosimetric comparison of manual beam angle selection (MBS) and beam angle optimization (BAO) for IMRT plans is investigated retrospectively for 15 head and neck and prostate patients. The head and neck and prostate had planning target volumes (PTVs) ranging between 96.0 and 319.9 cm 3 and 153.6 and 321.3 cm 3 , whereas OAR ranged between 8.3 and 47.8 cm 3 and 68.3 and 469.2 cm 3 , respectively. In MBS, a standard coplanar 7-9 fields equally spaced gantry angles were used. In BAO, the selection of gantry angle was optimized by the algorithm for the same number of beams. The optimization and dose-volume constraints were kept the same for both techniques. Treatment planning was performed on the Eclipse treatment planning system. Our results showed that the dose-volume histogram for PTV are nearly identical in both techniques but BAO provided superior sparing of the organs at risk compared with the MBS. Also, MBS produced statistically significant higher monitor units (MU) and segments than the BAO; 13.1 ± 6.6% (p = 0.012) and 10.4 ± 13.6% (p = 0.140), and 14.6 ± 5.6% (p = 1.003E-5) and 12.6 ± 7.4% (p = 0.76E-3) for head and neck and prostate cases, respectively. The reduction in MU translates into the reduction in total body and integral dose. It is concluded that BAO provides advantage over MBS for most intenisty-modulated radiation therapy cases.

  5. Dosimetric verification of IMRT plans

    International Nuclear Information System (INIS)

    Bulski, W.; Cheimicski, K.; Rostkowska, J.

    2012-01-01

    Intensity modulated radiotherapy (IMRT) is a complex procedure requiring proper dosimetric verification. IMRT dose distributions are characterized by steep dose gradients which enable to spare organs at risk and allow for an escalation of the dose to the tumor. They require large number of radiation beams (sometimes over 10). The fluence measurements for individual beams are not sufficient for evaluation of the total dose distribution and to assure patient safety. The methods used at the Centre of Oncology in Warsaw are presented. In order to measure dose distributions in various cross-sections the film dosimeters were used (radiographic Kodak EDR2 films and radiochromic Gafchromic EBT films). The film characteristics were carefully examined. Several types of tissue equivalent phantoms were developed. A methodology of comparing measured dose distributions against the distributions calculated by treatment planning systems (TPS) was developed and tested. The tolerance level for this comparison was set at 3% difference in dose and 3 mm in distance to agreement. The so called gamma formalism was used. The results of these comparisons for a group of over 600 patients are presented. Agreement was found in 87 % of cases. This film dosimetry methodology was used as a benchmark to test and validate the performance of commercially available 2D and 3D matrices of detectors (ionization chambers or diodes). The results of these validations are also presented. (authors)

  6. SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Niu, Y; Becker, S; Mutaf, Y; Yu, C

    2016-01-01

    Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

  7. Dosimetric comparison between helical tomotherapy and volumetric modulated arc-therapy for non-anaplastic thyroid cancer treatment.

    Science.gov (United States)

    Khalifa, Jonathan; Vieillevigne, Laure; Boyrie, Sabrina; Ouali, Monia; Filleron, Thomas; Rives, Michel; Laprie, Anne

    2014-11-26

    To evaluate and compare dosimetric parameters of volumetric modulated arctherapy (VMAT) and helical tomotherapy (HT) for non-anaplastic thyroid cancer adjuvant radiotherapy. Twelve patients with non-anaplastic thyroid cancer at high risk of local relapse received adjuvant external beam radiotherapy with curative intent in our institution, using a two-dose level prescription with a simultaneous integrated boost approach. Each patient was re-planned by the same physicist twice using both VMAT and HT. Several dosimetric quality indexes were used: target coverage index (proportion of the target volume covered by the reference isodose), healthy tissue conformity index (proportion of the reference isodose volume including the target volume), conformation number (combining both previous indexes), Dice Similarity Coefficient (DSC), and homogeneity index ((D2%-D98%)/prescribed dose). Dose-volume histogram statistics were also compared. HT provided statistically better target coverage index and homogeneity index for low risk PTV in comparison with VMAT (respectively 0.99 vs. 0.97 (p=0.008) and 0.22 vs. 0.25 (p=0.016)). However, HT provided poorer results for healthy tissue conformity index, conformation number and DSC with low risk and high risk PTV. As regards organs at risk sparing, by comparison with VMAT, HT statistically decreased the D2% to medullary canal (25.3 Gy vs. 32.6 Gy (p=0.003)). Besides, HT allowed a slight sparing dose for the controlateral parotid (Dmean: 4.3 Gy vs. 6.6 Gy (p=0.032)) and for the controlateral sub-maxillary gland (Dmean: 29.1 Gy vs. 33.1 Gy (p=0.041)). Both VMAT and HT techniques for adjuvant treatment of non-anaplastic thyroid cancer provide globally attractive treatment plans with slight dosimetric differences. However, helical tomotherapy clearly provides a benefit in term of medullary canal sparing.

  8. SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Y [Xcision Medical Systems LLC, Columbia, MD (United States); Becker, S; Mutaf, Y [University Maryland School of Medicine, Baltimore, MD (United States); Yu, C [Xcision Medical Systems LLC, Columbia, MD (United States); University Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

  9. Non-dosimetric quality assurance for the three-dimensional radiation treatment planning systems using a multi-leaf collimator phantom

    International Nuclear Information System (INIS)

    Tateoka, Kunihiko; Nagase, Daiki; Sato, Takahito; Shimizume, Kazunari; Ouchi, Atsushi; Nakata, Kensei; Hareyama, Masato

    2008-01-01

    Evaluation of errors and limitations in simulation software for three-dimensional radiation treatment systems (3D-RTPS) is an important issue. Non-dosimetric quality assurance (QA) of the simulation software of 3D-RTPS was evaluated by graphical displays of JAW and multi-leaf collimator (MLC) settings in a 3D-RTPS. The influence of observations made using the phantom depends on human errors and several parameters of the CT scan set, such as slice thickness and spacing, pixel size, partial volume effects and the reconstructed image orientation. We explored the methods that were minimally influenced by these errors and parameters. The QA phantom (MLC phantom) has been designed for checking a JAW and MLC settings in a 3D-RTPS is used for non-dosimetric QA. We analyzed the CT value of the boundary the structures of the MLC phantom. The relative CT value for thickness 1 mm slice in border of each structure body of MLC phantom respectively shows a decrease of about 2%, 4%, 10% by 2 mm, 3 mm and 5 mm. In case of thickness 5 mm slice, the mean deference of border of virtual radiation beams and phantom was 0.8 mm, and standard deviation of them was 0.6 mm. And the mean difference of border of a DRR image and phantom was 0.08 mm and the standard deviation of them 0.6 mm. In case of thickness 2 mm slice, the mean deference of border of virtual radiation beams and phantom was -0.18 mm, and standard deviation of them was 0.32 mm. And the mean difference of border of a DRR image and phantom was 0.87 mm and the standard deviation of them 0.54 mm. The result of the study is useful for improvement in a precision of non-dosimetric QA. Our method of non-dosimetric QA can minimize human error and influence of several parameters of the CT scan set. The MLC phantom is a useful tool in the QA of radiation therapy with application to 3D-RTPS, CT simulators, and virtual simulation packages with MLC display capabilities. (author)

  10. Effect of blood activity on dosimetric calculations for radiopharmaceuticals

    Science.gov (United States)

    Zvereva, Alexandra; Petoussi-Henss, Nina; Li, Wei Bo; Schlattl, Helmut; Oeh, Uwe; Zankl, Maria; Graner, Frank Philipp; Hoeschen, Christoph; Nekolla, Stephan G.; Parodi, Katia; Schwaiger, Markus

    2016-11-01

    dosimetric calculations. Hence, blood samples should be included in all pharmacokinetic and dosimetric studies for new tracers if possible.

  11. Investigation of clinical and dosimetric factors associated with postoperative pulmonary complications in esophageal cancer patients treated with concurrent chemoradiotherapy followed by surgery

    International Nuclear Information System (INIS)

    Wang Shulian; Liao Zhongxing; Vaporciyan, Ara A.; Tucker, Susan L.; Liu, Helen; Wei Xiong; Swisher, Stephen; Ajani, Jaffer A.; Cox, James D.; Komaki, Ritsuko

    2006-01-01

    Purpose: To assess the association of clinical and especially dosimetric factors with the incidence of postoperative pulmonary complications among esophageal cancer patients treated with concurrent chemoradiation therapy followed by surgery. Method and Materials: Data from 110 esophageal cancer patients treated between January 1998 and December 2003 were analyzed retrospectively. All patients received concurrent chemoradiotherapy followed by surgery; 72 patients also received irinotecan-based induction chemotherapy. Concurrent chemotherapy was 5-fluorouracil-based and in 97 cases included taxanes. Radiotherapy was delivered to a total dose of 41.4-50.4 Gy at 1.8-2.0 Gy per fraction with a three-dimensional conformal technique. Surgery (three-field, Ivor-Lewis, or transhiatal esophagectomy) was performed 27-123 days (median, 45 days) after completion of radiotherapy. The following dosimetric parameters were generated from the dose-volume histogram (DVH) for total lung: lung volume, mean dose to lung, relative and absolute volumes of lung receiving more than a threshold dose (relative V dose and absolute V dose ), and absolute volume of lung receiving less than a threshold dose (volume spared, or VS dose ). Occurrence of postoperative pulmonary complications, defined as pneumonia or acute respiratory distress syndrome (ARDS) within 30 days after surgery, was the endpoint for all analyses. Fisher's exact test was used to investigate the relationship between categorical factors and incidence of postoperative pulmonary complications. Logistic analysis was used to analyze the relationship between continuous factors (e.g., V dose or VS dose ) and complication rate. Logistic regression with forward stepwise inclusion of factors was used to perform multivariate analysis of those factors having univariate significance (p < 0.05). The Mann-Whitney test was used to compare length of hospital stay in patients with and without lung complications and to compare lung volumes, VS5

  12. Dosimetric characterization of the 18-MV photon beam from the Siemens Mevatron 77 linear accelerator

    International Nuclear Information System (INIS)

    Palta, J.R.; Meyer, J.A.; Hogstrom, K.R.

    1984-01-01

    A comprehensive set of dosimetric measurements has been made on the Mevatron 77.80.67 18-MV photon beam. Percentage depth dose, dose in the buildup region, field size dependence of output, transmission through lead, tray attenuation, and isodose curves for the open and wedged fields were measured using an ionization chamber in water and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose at 10-cm depth for a 10 x 10 cm 2 field at 100-cm source-to-skin distance (SSD) is 80.9%, which meets design specifications. Central axis depth-dose data were fitted to within 0.5% by a set of polynomial equations utilizing a two-dimensional linear regression analysis. Tissue--maximum ratios calculated from depth-dose data agree with measured data to within 2%. Output differences as large as 2.5% were measured for rectangular fields depending on which collimator jaws defined the long dimension of the field. The field size dependence of output was fit to within +- 0.1% by a linear regression. The half-value thickness of the beam was measured to be 13 mm of lead

  13. Dosimetric properties of dysprosium doped calcium magnesium borate glass subjected to Co-60 gamma ray

    Energy Technology Data Exchange (ETDEWEB)

    Omar, R. S., E-mail: ratnasuffhiyanni@gmail.com; Wagiran, H., E-mail: husin@utm.my; Saeed, M. A. [Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor Bahru (Malaysia)

    2016-01-22

    Thermoluminescence (TL) dosimetric properties of dysprosium doped calcium magnesium borate (CMB:Dy) glass are presented. This study is deemed to understand the application of calcium as the modifier in magnesium borate glass with the presence of dysprosium as the activator to be performed as TL dosimeter (TLD). The study provides fundamental knowledge of a glass system that may lead to perform new TL glass dosimetry application in future research. Calcium magnesium borate glass systems of (70-y) B{sub 2}O{sub 3} − 20 CaO – 10 MgO-(y) Dy{sub 2}O{sub 3} with 0.05  mol % ≤ y ≤ 0.7  mol % of dyprosium were prepared by melt-quenching technique. The amorphous structure and TL properties of the prepared samples were determined using powder X-ray diffraction (XRD) and TL reader; model Harshaw 4500 respectively. The samples were irradiated to Co-60 gamma source at a dose of 50 Gy. Dosimetric properties such as annealing procedure, time temperature profile (TTP) setting, optimization of Dy{sub 2}O{sub 3} concentration of 0.5 mol % were determined for thermoluminescence dosimeter (TLD) reader used.

  14. Recovery of α-Al{sub 2}O{sub 3} from ionizing radiation dosimetric sensors

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Edgar Aparecido, E-mail: sanches.ufam@gmail.com [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil). Dept. de Fisica; Costalonga, Ademir Geraldo Cavallari; Mascarenhas, Yvonne Primerano [Universidade de Sao Paulo (IFSC/USP), Sao Carlos, SP (Brazil). Institute de Fisica; Nascimento, Luana de Freitas [Belgium Nuclear Research Centre, SCK-CEN, Mol (Belgium); Mascarenhas, Yvone Maria [SAPRA S/A Servico de Assessoria e Protecao Radiologica, Sao Carlos, SP, (Brazil)

    2015-01-15

    Corundum, sapphire or α-Al{sub 2}O{sub 3} is an important technological material in many optical and electronic applications such as solid-state lasers, optical windows and, more recently, as a radiation detector. Landauer (Glenwood, IL, USA) accumulated large number of archived and stored Luxel™ dosemeters composed of Al{sub 2}O{sub 3}:C, which were subjected to a recovery process. Due to the importance of this advanced crystalline material in OSL dosimetry, a recovery process was developed based on the dosemeters calcination and Al{sub 2}O{sub 3}:C has been reused in manufacturing of new dosemeters. This paper does not aim to optimize the recovery process, but provides an opportunity to study the involved process parameters and to recover this valuable crystalline material from used dosemeters. To the best of our knowledge no other recovery process involving this dosimetric material was described in scientific literature. Fourier Transform Infrared Spectrometry (FTIR), Thermogravimetry/Differential Thermoanalysis (TG/DTA), Differential Scanning Calorimetry (DSC), X-ray Diffraction (XRD), Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Optically Stimulated Luminescence (OSL) and Rietveld Refinement were used to characterize the recovered material and to check for the stability of its structural and dosimetric properties. (author)

  15. Role of intracanalicular volumetric and dosimetric parameters on hearing preservation after vestibular schwannoma radiosurgery

    International Nuclear Information System (INIS)

    Massager, Nicolas; Nissim, Ouzi; Delbrouck, Carine; Devriendt, Daniel; David, Philippe; Desmedt, Francoise; Wikler, David; Hassid, Sergio; Brotchi, Jacques; Levivier, Marc

    2006-01-01

    Purpose: To analyze the relationship between hearing preservation after gamma knife radiosurgery (GKR) for vestibular schwannoma (VS) and some volumetric and dosimetric parameters of the intracanalicular components of VS. Methods and Materials: This study included 82 patients with a VS treated by GKR; all patients had no NF2 disease, a Gardner-Robertson hearing class 1-4 before treatment, a marginal dose of 12 Gy, and a radiologic and audiologic follow-up ≥1 year post-GKR. The volume of both the entire tumor and the intracanalicular part of the tumor and the mean and integrated dose of these two volumes were correlated to the auditory outcomes of patients. Results: At last hearing follow-up, 52 patients had no hearing worsening, and 30 patients had an increase of ≥1 class on Gardner-Robertson classification. We found that hearing preservation after GKR is significantly correlated with the intracanalicular tumor volume, as well as with the integrated dose delivered to the intracanalicular tumor volume. Conclusions: Some volumetric and dosimetric parameters of the intracanalicular part of the tumor influence hearing preservation after GKR of VS. Consequently, we advise the direct treatment of patients with preserved functional hearing and a VS including a small intracanalicular volume

  16. Comparison of dosimetric characteristics of Siemens virtual and physical wedges for ONCOR linear accelerator

    Directory of Open Access Journals (Sweden)

    Attalla Ehab

    2010-01-01

    Full Text Available Dosimetric properties of virtual wedge (VW and physical wedge (PW in 6- and 10-MV photon beams from a Siemens ONCOR linear accelerator, including wedge factors, depth doses, dose profiles, peripheral doses, are compared. While there is a great difference in absolute values of wedge factors, VW factors (VWFs and PW factors (PWFs have a similar trend as a function of field size. PWFs have stronger depth dependence than VWF due to beam hardening in PW fields. VW dose profiles in the wedge direction, in general, match very well with those of PW, except in the toe area of large wedge angles with large field sizes. Dose profiles in the nonwedge direction show a significant reduction in PW fields due to off-axis beam softening and oblique filtration. PW fields have significantly higher peripheral doses than open and VW fields. VW fields have similar surface doses as the open fields, while PW fields have lower surface doses. Surface doses for both VW and PW increase with field size and slightly with wedge angle. For VW fields with wedge angles 45° and less, the initial gap up to 3 cm is dosimetrically acceptable when compared to dose profiles of PW. VW fields in general use less monitor units than PW fields.

  17. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance

    International Nuclear Information System (INIS)

    Fuss, Martina; Sturtewagen, Eva; Wagter, Carlos De; Georg, Dietmar

    2007-01-01

    The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as well as relative dosimetry when compared to absolute absorbed dose calibrated using ionization chamber results. For comparison, a silver halide film (Kodak EDR-2) representing the current standard in film dosimetry was included. As an initial step a measurement protocol yielding accurate and precise results was established for a flatbed transparency scanner (Epson Expression 1680 Pro) that was utilized as a film reading instrument. The light transmission measured by the scanner was found to depend on the position of the film on the scanner plate. For three film pieces irradiated with doses of 0 Gy, ∼1 Gy and ∼7 Gy, the pixel values measured in portrait or landscape mode differed by 4.7%, 6.2% and 10.0%, respectively. A study of 200 film pieces revealed an excellent sheet-to-sheet uniformity. On a long time scale, the optical development of irradiated EBT film consisted of a slow but steady increase of absorbance which was not observed to cease during 4 months. Sensitometric curves of EBT films obtained under reference conditions (SSD = 95 cm, FS = 5 x 5 cm 2 , d = 5 cm) for 6, 10 and 25 MV photon beams did not show any energy dependence. The average separation between all curves was only 0.7%. The variation of the depth d (range 2-25 cm) in the phantom did not affect the dose response of EBT film. Also the influence of the radiation field size (range 3 x 3-40 x 40 cm 2 ) on the sensitometric curve was not significant. For EDR-2 films maximum differences between the calibration curves reached 7-8% for X6MV and X25MV. Radiochromic EBT film, in combination with a flatbed

  18. Recommendations for equipment requirements and specifications for digital and interventional radiology: Dosimetric aspects

    International Nuclear Information System (INIS)

    Suliman, I.I.; Zoetelief, J.

    2002-01-01

    The recognition of radiation induced injuries from fluoroscopically guided interventional procedures has resulted in the current demand for development of recommendations and standards to limit dose to both patients and staff. This paper outlines the recommendations drafted within the framework of European Project DIMOND III. The actual work involves survey and review of national and international documents as well as scientific publications in areas relevant to the digital and/or interventional radiology with an aim of developing recommendations for equipment requirements and specifications for digital and interventional radiology. A pilot study of experimental investigations in at least three hospitals will be conducted to test the requirements and the specifications, the result of which will be presented. The recommendations are expected to provide an effective means of dose reduction to both patients and staff while maintaining image quality adequate for the specific diagnosis or interventional procedure. Different components of x-ray systems that have direct impact on patient and staff doses have been considered. Where necessary a compromise between patient dose and image quality has been made. The dosimetric aspects of the recommendations propose detailed descriptions and limits to dosimetric information relevant to patient and staff doses. International recommendations on maximum patient entrance surface dose rate vary in the range from 25 to 65 mGy.min -1 for normal mode fluoroscopy. Maximum image intensifier or image receptor input dose rate around 0.1 Gy min -1 at a distance 30 cm from the image intensifier input surface has been generally recommended. Maximum fluoroscopic dose rate in air must not exceed 50 mGy.min -1 at a location depending on the configuration e.g. for undertable x-ray tube at 10 mm from the patient support on the patient side of the support. The use of pulsed fluoroscopy or low dose fluoroscopy is proposed as good options to minimize

  19. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  20. SU-E-T-368: Evaluating Dosimetric Outcome of Modulated Photon Radiotherapy (XMRT) Optimization for Head and Neck Patients

    Energy Technology Data Exchange (ETDEWEB)

    McGeachy, P; Villarreal-Barajas, JE; Khan, R [University of Calgary, Calgary, AB (Canada); Tom Baker Cancer Centre, Calgary, AB (Canada); Zinchenko, Y [University of Calgary, Calgary, AB (Canada)

    2015-06-15

    Purpose: The dosimetric outcome of optimized treatment plans obtained by modulating the photon beamlet energy and fluence on a small cohort of four Head and Neck (H and N) patients was investigated. This novel optimization technique is denoted XMRT for modulated photon radiotherapy. The dosimetric plans from XMRT for H and N treatment were compared to conventional, 6 MV intensity modulated radiotherapy (IMRT) optimization plans. Methods: An arrangement of two non-coplanar and five coplanar beams was used for all four H and N patients. Both XMRT and IMRT were subject to the same optimization algorithm, with XMRT optimization allowing both 6 and 18 MV beamlets while IMRT was restricted to 6 MV only. The optimization algorithm was based on a linear programming approach with partial-volume constraints implemented via the conditional value-at-risk method. H and N constraints were based off of those mentioned in the Radiation Therapy Oncology Group 1016 protocol. XMRT and IMRT solutions were assessed using metrics suggested by International Commission on Radiation Units and Measurements report 83. The Gurobi solver was used in conjunction with the CVX package to solve each optimization problem. Dose calculations and analysis were done in CERR using Monte Carlo dose calculation with VMC{sub ++}. Results: Both XMRT and IMRT solutions met all clinical criteria. Trade-offs were observed between improved dose uniformity to the primary target volume (PTV1) and increased dose to some of the surrounding healthy organs for XMRT compared to IMRT. On average, IMRT improved dose to the contralateral parotid gland and spinal cord while XMRT improved dose to the brainstem and mandible. Conclusion: Bi-energy XMRT optimization for H and N patients provides benefits in terms of improved dose uniformity to the primary target and reduced dose to some healthy structures, at the expense of increased dose to other healthy structures when compared with IMRT.

  1. Biokinetic and dosimetric studies of {sup 188}Re-hyaluronic acid: a new radiopharmaceutical for treatment of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Melendez-Alafort, Laura [Dipartimento di Scienze Farmaceutiche, Universita degli Studi di Padova, 35131 Padua (Italy); Nadali, Anna; Zangoni, Elena [Dipartimento di Scienze Farmaceutiche, Universita degli Studi di Padova, 35131 Padua (Italy); Banzato, Alessandra; Rondina, Maria [Dipartimento di Scienze Oncologiche e Chirurgiche, Universita degli Studi di Padova, Padua (Italy); Rosato, Antonio [Dipartimento di Scienze Oncologiche e Chirurgiche, Universita degli Studi di Padova, Padua (Italy); Istituto Oncologico Veneto, IOV, Padova, Padua (Italy); Mazzi, Ulderico [Dipartimento di Scienze Farmaceutiche, Universita degli Studi di Padova, 35131 Padua (Italy)

    2009-08-15

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and aspartate aminotranferase (ALT) levels in mice were assessed and the liver maximum tolerated dose (MTD) of {sup 188}Re-HA was determined. Results: A stable complex of {sup 188}Re-HA was obtained with high radiochemical purity (>90%) and low serum protein binding (2%). Biokinetic studies showed a rapid blood clearance (T{sub 1/2}{alpha}=21 min). Four hours after administration, {sup 188}Re-HA was almost totally removed from the blood by the liver due to the selective uptake via HA-specific receptors (73.47{+-}5.11% of the injected dose). The liver MTD in mice was {approx}40 Gy after 7.4 MBq of {sup 188}Re-HA injection. Conclusions: {sup 188}Re-HA complex showed good stability, pharmacokinetic and dosimetric characteristics that confirm its potential as a new agent for HCC radiation therapy.

  2. Evaluation of physiological parameters and their influence on doses calculated from two alternative dosimetric models for the gastrointestinal tract

    International Nuclear Information System (INIS)

    Lessard, E.T.; Skrable, K.W.

    1981-01-01

    Two dosimetric models, the catenary compartmental model and the slug flow model are examined using three sets of physiological parameters. The impact of physiological parameters on the dosimetry of the tract is illustrated by comparing calculated maximum permissible daily activity ingestion rates for single, unabsorbed, particle emitting radionuclides with an effective energy term of unity. The conclusions drawn from this intercomparison of six different cases are: (1) Current dosimetric models which use physiological parameters described in this article do not significantly disagree, and (2) For the determination of average dose equivalent rates to segments of the tract due to chronic, long term ingestion of any radionuclide, the catenary compartmental model is a mathematically simpler approach. The catenary model in addition has certain advantages for the calculation of the photon dose contribution to one segment from cumulated activity (disintegrations) in another segment

  3. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  4. Study and evaluation of the Siemens virtual wedge factor: dosimetric monitor system and variable field effects

    Energy Technology Data Exchange (ETDEWEB)

    Sendon Rio, J R Sendon; Martinez, C Otero; GarcIa, M Sanchez; Busto, R Lobato; Vega, V Luna; Sueiro, J Mosquera; Camean, M Pombar [Servizo de Radiofisica e Proteccion Radioloxica, Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Santiago de Compostela (Spain)], E-mail: jose.ramon.sendon.del.rio@sergas.es

    2008-03-07

    In the year 1997 Siemens introduced the virtual wedge in its accelerators. The idea was that a dose profile similar to that of a physical wedge can be obtained by moving one of the accelerator jaws at a constant speed while the dose rate is changing. This work explores the observed behaviour of virtual wedge factors. A model is suggested which takes into account that at any point in time, when the jaw moves, the dose at a point of interest in the phantom is not only due to the direct beam. It also depends on the scattered radiation in the phantom, the head scatter and the behaviour of the monitoring system of the accelerator. Measurements are performed in a Siemens Primus accelerator and compared to the model predictions. It is shown that the model agrees reasonably well with measurements spanning a wide range of conditions. A strong dependence of virtual wedge factors on the dosimetric board has been confirmed and an explanation has been given on how the balance between different contributions is responsible for virtual wedge factors values.

  5. Dosimetric effects of saline- versus water-filled balloon applicators for IORT using the model S700 electronic brachytherapy source.

    Science.gov (United States)

    Redler, Gage; Templeton, Alistair; Zhen, Heming; Turian, Julius; Bernard, Damian; Chu, James C H; Griem, Katherine L; Liao, Yixiang

    The Xoft Axxent Electronic Brachytherapy System (Xoft, Inc., San Jose, CA) is a viable option for intraoperative radiation therapy (IORT) treatment of early-stage breast cancer. The low-energy (50-kVp) X-ray source simplifies shielding and increases relative biological effectiveness but increases dose distribution sensitivity to medium composition. Treatment planning systems typically assume homogenous water for brachytherapy dose calculations, including precalculated atlas plans for Xoft IORT. However, Xoft recommends saline for balloon applicator filling. This study investigates dosimetric differences due to increased effective atomic number (Z eff ) for saline (Z eff  = 7.56) versus water (Z eff  = 7.42). Balloon applicator diameters range from 3 to 6 cm. Monte Carlo N-Particle software is used to calculate dose at the surface (D s ) of and 1 cm away (D 1cm ) from the water-/saline-filled balloon applicator using a single dwell at the applicator center as a simple estimation of the dosimetry and multiple dwells simulating the clinical dose distributions for the atlas plans. Single-dwell plans show a 4.4-6.1% decrease in D s for the 3- to 6-cm diameter applicators due to the saline. Multidwell plans show similar results: 4.9% and 6.4% D s decrease, for 4-cm and 6-cm diameter applicators, respectively. For the single-dwell plans, D 1cm decreases 3.6-5.2% for the 3- to 6-cm diameter applicators. For the multidwell plans, D 1cm decreases 3.3% and 5.3% for the 4-cm and 6-cm applicators, respectively. The dosimetric effect introduced by saline versus water filling for Xoft balloon applicator-based IORT treatments is ∼5%. Users should be aware of this in the context of both treatment planning and patient outcome studies. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Dosimetric Predictors of Duodenal Toxicity After Intensity Modulated Radiation Therapy for Treatment of the Para-aortic Nodes in Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Jonathan [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Sulman, Erik P.; Jhingran, Anuja [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Tucker, Susan L. [Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rauch, Gaiane M. [Department of Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Eifel, Patricia J. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Klopp, Ann H., E-mail: aklopp@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-02-01

    Purpose: To determine the incidence of duodenal toxicity in patients receiving intensity modulated radiation therapy (IMRT) for treatment of para-aortic nodes and to identify dosimetric parameters predictive of late duodenal toxicity. Methods and Materials: We identified 105 eligible patients with gynecologic malignancies who were treated with IMRT for gross metastatic disease in the para-aortic nodes from January 1, 2005, through December 31, 2009. Patients were treated to a nodal clinical target volume to 45 to 50.4 Gy with a boost to 60 to 66 Gy. The duodenum was contoured, and dosimetric data were exported for analysis. Duodenal toxicity was scored according to Radiation Therapy Oncology Group criteria. Univariate Cox proportional hazards analysis and recursive partitioning analysis were used to determine associations between dosimetric variables and time to toxicity and to identify the optimal threshold that separated patients according to risk of toxicity. Results: Nine of the 105 patients experienced grade 2 to grade 5 duodenal toxicity, confirmed by endoscopy in all cases. The 3-year actuarial rate of any duodenal toxicity was 11.7%. A larger volume of the duodenum receiving 55 Gy (V55) was associated with higher rates of duodenal toxicity. The 3-year actuarial rates of duodenal toxicity with V55 above and below 15 cm{sup 3} were 48.6% and 7.4%, respectively (P<.01). In Cox univariate analysis of dosimetric variables, V55 was associated with duodenal toxicity (P=.029). In recursive partitioning analysis, V55 less than 13.94% segregated all patients with duodenal toxicity. Conclusions: Dose-escalated IMRT can safely and effectively treat para-aortic nodal disease in gynecologic malignancies, provided that care is taken to limit the dose to the duodenum to reduce the risk of late duodenal toxicity. Limiting V55 to below 15 cm{sup 3} may reduce the risk of duodenal complications. In cases where the treatment cannot be delivered within these constraints

  7. Characterizing Interfraction Variations and Their Dosimetric Effects in Prostate Cancer Radiotherapy

    International Nuclear Information System (INIS)

    Peng Cheng; Ahunbay, Ergun; Chen Guangpei; Anderson, Savannah; Lawton, Colleen; Li, X. Allen

    2011-01-01

    Purpose: To quantitatively characterize the interfraction variations and their dosimetric effects in radiotherapy for prostate cancer. Methods and Materials: A total of 486 daily computed tomography (CT) sets acquired for 20 prostate cancer patients treated with daily CT-guided repositioning using a linear accelerator and CT-on-rail combination were analyzed. The prostate, rectum, and bladder, delineated on each daily CT data set, were compared with those from the planning CT scan. Several quantities, including Dice's coefficient and the maximal overlapping rate, were used to characterize the interfraction variations. The delivered dose was reconstructed by applying the original plan to the daily CT scan with consideration of proper repositioning. Results: The mean prostate Dice's coefficient and maximal overlapping rate after bony registration was 69.7% ± 13.8% (standard deviation) and 85.6% ± 7.8% (standard deviation), respectively. The daily delivered dose distributions were generally inferior to the planned dose distribution for target coverage and/or normal structure sparing. For example, for approximately 5% of the treatment fractions, the prostate volume receiving 100% of the prescription dose decreased dramatically (15-20%) compared with its planned value. The magnitudes of the interfraction variations and their dosimetric effects indicated that, statistically, current standard repositioning using prostate alignment might be adequate for two-thirds of the fractions, but for the rest of the fractions, better on-line correction strategies, such as on-line replanning, are needed. Conclusion: Different adaptive correction schemes for prostatic interfraction changes can be used according to the anatomic changes, as quantified by the organ displacement and deformation parameters. On-line replanning is needed for approximately one-third of the treatment fractions.

  8. Dosimetric impact of inter-observer variability for 3D conformal radiotherapy and volumetric modulated arc therapy: the rectal tumor target definition case

    International Nuclear Information System (INIS)

    Lobefalo, Francesca; Cozzi, Luca; Scorsetti, Marta; Mancosu, Pietro; Bignardi, Mario; Reggiori, Giacomo; Tozzi, Angelo; Tomatis, Stefano; Alongi, Filippo; Fogliata, Antonella; Gaudino, Anna; Navarria, Piera

    2013-01-01

    To assess the dosimetric effect induced by inter-observer variability in target definition for 3D-conformal RT (3DCRT) and volumetric modulated arc therapy by RapidArc (RA) techniques for rectal cancer treatment. Ten patients with rectal cancer subjected to neo-adjuvant RT were randomly selected from the internal database. Four radiation oncologists independently contoured the clinical target volume (CTV) in blind mode. Planning target volume (PTV) was defined as CTV + 7 mm in the three directions. Afterwards, shared guidelines between radiation oncologists were introduced to give general criteria for the contouring of rectal target and the four radiation oncologists defined new CTV following the guidelines. For each patient, six intersections (I) and unions (U) volumes were calculated coupling the contours of the various oncologists. This was repeated for the contours drawn after the guidelines. Agreement Index (AI = I/U) was calculated pre and post guidelines. Two RT plans (one with 3DCRT technique using 3–4 fields and one with RA using a single modulated arc) were optimized on each radiation oncologist’s PTV. For each plan the PTV volume receiving at least 95% of the prescribed dose (PTV V95%) was calculated for both target and non-target PTVs. The inter-operator AI pre-guidelines was 0.57 and was increased up to 0.69 post-guidelines. The maximum volume difference between the various CTV couples, drawn for each patient, passed from 380 ± 147 cm 3 to 137 ± 83 cm 3 after the introduction of guidelines. The mean percentage for the non-target PTV V95% was 93.7 ± 9.2% before and 96.6 ± 4.9%after the introduction of guidelines for the 3DCRT, for RA the increase was more relevant, passing from 86.5 ± 13.8% (pre) to 94.5 ± 7.5% (post). The OARs were maximally spared with VMAT technique while the variability between pre and post guidelines was not relevant in both techniques. The contouring inter-observer variability has dosimetric effects in the PTV coverage

  9. SU-E-T-119: Dosimetric and Mechanical Characteristics of Elekta Infinity LINAC with Agility MLC

    International Nuclear Information System (INIS)

    Park, J; Xu, Q; Xue, J; Zhai, Y; An, L; Chen, Y

    2014-01-01

    Purpose: Elekta Infinity is the one of the latest generation LINAC with unique features. Two Infinity LINACs are recently commissioned at our institution. The dosimetric and mechanical characteristics of the machines are presented. Methods: Both Infinity LINACs with Agility MLC (160 leaves with 0.5 cm leaf width) are configured with five electron energies (6, 9, 12, 15, and 18 MeV) and two photon energies (6 and 15 MV). One machine has additional photon energy (10 MV). The commissioning was performed by following the manufacturer's specifications and AAPM TG recommendations. Beam data of both electron and photon beams are measured with scanning ion chambers and linear diode array. Machines are adjusted to have the dosimetrically equivalent characteristics. Results: The commissioning of mechanical and imaging system meets the tolerances by TG recommendations. The PDD 10 of various field sizes for 6 and 15 MV shows < 0.5% difference between two machines. For each electron beams, R 80 matches with < 0.4 mm difference. The symmetry and flatness agree within 0.8% and 0.9% differences for photon beams, respectively. For electron beams, the differences of the symmetry and flatness are within 1.2% and 0.8%, respectively. The mean inline penumbras for 6, 10, and 15 MV are respectively 5.1±0.24, 5.6±0.07, and 5.9±0.10 mm for 10x10 cm at 10 cm depth. The crossline penumbras are larger than inline penumbras by 2.2, 1.4, and 1.0 mm, respectively. The MLC transmission factor with interleaf leakage is 0.5 % for all photon energies. Conclusion: The dosimetric and mechanical characteristics of two Infinity LINACs show good agreements between them. Although the Elekta Infinity has been used in many institutions, the detailed characteristics of the machine have not been reported. This study provides invaluable information to understand the Infinity LINAC and to compare the quality of commissioning data for other LINACs

  10. SU-E-T-123: Dosimetric Comparison Between Portrait and Landscape Orientations in Radiochromic Film Dosimetry

    International Nuclear Information System (INIS)

    Kakinohana, Y; Toita, T; Kasuya, G; Ariga, T; Heianna, J; Murayama, S

    2014-01-01

    Purpose: To compare the dosimetric properties of radiochromic films with different orientation. Methods: A sheet of EBT3 film was cut into eight pieces with the following sizes: 15×15 cm2 (one piece), 5x15 cm 2 (two) and 4×5 cm 2 (five). A set of two EBT3 sheets was used at each dose level. Two sets were used changing the delivered doses (1 and 2 Gy). The 5×15 cm 2 pieces were rotated by 90 degrees in relation to each other, such that one had landscape orientation and the other had portrait orientation. All 5×15 cm2 pieces were irradiated with their long side aligned with the x-axis of the radiation field. The 15×15 cm 2 pieces were irradiated rotated at 90 degrees to each other. Five pieces, (a total of ten from two sheets) were used to obtain a calibration curve. The irradiated films were scanned using an Epson ES-2200 scanner and were analyzed using ImageJ software. In this study, no correction was applied for the nonuniform scanner signal that is evident in the direction of the scanner lamp. Each film piece was scanned both in portrait and landscape orientations. Dosimetric comparisons of the beam profiles were made in terms of the film orientations (portrait and landscape) and scanner bed directions (perpendicular and parallel to the scanner movement). Results: In general, portrait orientation exhibited higher noise than landscape and was adversely affected to a great extent by the nonuniformity in the direction of the scanner lamp. A significant difference in the measured field widths between the perpendicular and parallel directions was found for both orientations. Conclusion: Without correction for the nonuniform scanner signal in the direction of the scanner lamp, a landscape orientation is preferable. A more detailed investigation is planned to evaluate quantitatively the effect of orientation on the dosimetric properties of a film

  11. SU-E-T-123: Dosimetric Comparison Between Portrait and Landscape Orientations in Radiochromic Film Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kakinohana, Y [University of the Ryukyus, Okinawa (Japan); Toita, T; Kasuya, G; Ariga, T; Heianna, J; Murayama, S [University of the Ryukyus, Nishihara-cho, Okinawa (Japan)

    2014-06-01

    Purpose: To compare the dosimetric properties of radiochromic films with different orientation. Methods: A sheet of EBT3 film was cut into eight pieces with the following sizes: 15×15 cm2 (one piece), 5x15 cm{sup 2} (two) and 4×5 cm{sup 2} (five). A set of two EBT3 sheets was used at each dose level. Two sets were used changing the delivered doses (1 and 2 Gy). The 5×15 cm{sup 2} pieces were rotated by 90 degrees in relation to each other, such that one had landscape orientation and the other had portrait orientation. All 5×15 cm2 pieces were irradiated with their long side aligned with the x-axis of the radiation field. The 15×15 cm{sup 2} pieces were irradiated rotated at 90 degrees to each other. Five pieces, (a total of ten from two sheets) were used to obtain a calibration curve. The irradiated films were scanned using an Epson ES-2200 scanner and were analyzed using ImageJ software. In this study, no correction was applied for the nonuniform scanner signal that is evident in the direction of the scanner lamp. Each film piece was scanned both in portrait and landscape orientations. Dosimetric comparisons of the beam profiles were made in terms of the film orientations (portrait and landscape) and scanner bed directions (perpendicular and parallel to the scanner movement). Results: In general, portrait orientation exhibited higher noise than landscape and was adversely affected to a great extent by the nonuniformity in the direction of the scanner lamp. A significant difference in the measured field widths between the perpendicular and parallel directions was found for both orientations. Conclusion: Without correction for the nonuniform scanner signal in the direction of the scanner lamp, a landscape orientation is preferable. A more detailed investigation is planned to evaluate quantitatively the effect of orientation on the dosimetric properties of a film.

  12. Dosimetric consequences of pencil beam width variations in scanned beam particle therapy

    International Nuclear Information System (INIS)

    Chanrion, M A; Ammazzalorso, F; Wittig, A; Engenhart-Cabillic, R; Jelen, U

    2013-01-01

    Scanned ion beam delivery enables the highest degree of target dose conformation attainable in external beam radiotherapy. Nominal pencil beam widths (spot sizes) are recorded during treatment planning system commissioning. Due to changes in the beam-line optics, the actual spot sizes may differ from these commissioning values, leading to differences between planned and delivered dose. The purpose of this study was to analyse the dosimetric consequences of spot size variations in particle therapy treatment plans. For 12 patients with skull base tumours and 12 patients with prostate carcinoma, scanned-beam carbon ion and proton treatment plans were prepared and recomputed simulating spot size changes of (1) ±10% to simulate the typical magnitude of fluctuations, (2) ±25% representing the worst-case scenario and (3) ±50% as a part of a risk analysis in case of fault conditions. The primary effect of the spot size variation was a dose deterioration affecting the target edge: loss of target coverage and broadening of the lateral penumbra (increased spot size) or overdosage and contraction of the lateral penumbra (reduced spot size). For changes ⩽25%, the resulting planning target volume mean 95%-isodose line coverage (CI-95%) deterioration was ranging from negligible to moderate. In some cases changes in the dose to adjoining critical structures were observed. (paper)

  13. Helical Tomotherapy in Children and Adolescents: Dosimetric Comparisons, Opportunities and Issues

    Energy Technology Data Exchange (ETDEWEB)

    Mascarin, Maurizio, E-mail: mascarin@cro.it [Pediatric Radiotherapy Unit, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Department of Radiation Therapy, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Giugliano, Francesca Maria [Pediatric Radiotherapy Unit, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Seconda Università di Napoli, Napoli 80138 (Italy); Coassin, Elisa [Pediatric Radiotherapy Unit, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Drigo, Annalisa; Chiovati, Paola; Dassie, Andrea [Department of Radiation Therapy, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Department of Medical Physics, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy); Franchin, Giovanni; Minatel, Emilio; Trovò, Mauro Gaetano [Department of Radiation Therapy, Centro di Riferimento Oncologico- National Cancer Institute/Via Franco Gallini, 2 33081 Aviano (PN) (Italy)

    2011-10-25

    Helical Tomotherapy (HT) is a highly conformal image-guided radiation technique, introduced into clinical routine in 2006 at the Centro di Riferimento Oncologico Aviano (Italy). With this new technology, intensity-modulated radiotherapy (IMRT) is delivered using a helicoidal method. Here we present our dosimetric experiences using HT in 100 children, adolescents and young adults treated from May 2006 to February 2011. The median age of the patients was 13 years (range 1–24). The most common treated site was the central nervous system (50; of these, 24 were craniospinal irradiations), followed by thorax (22), head and neck (10), abdomen and pelvis (11), and limbs (7). The use of HT was calculated in accordance to the target dose conformation, the target size and shape, the dose to critical organs adjacent to the target, simultaneous treatment of multiple targets, and re-irradiation. HT has demonstrated to improve target volume dose homogeneity and the sparing of critical structures, when compared to 3D Linac-based radiotherapy (RT). In standard cases this technique represented a comparable alternative to IMRT delivered with conventional linear accelerator. In certain cases (e.g., craniospinal and pleural treatments) only HT generated adequate treatment plans with good target volume coverage. However, the gain in target conformality should be balanced with the spread of low-doses to distant areas. This remains an open issue for the potential risk of secondary malignancies (SMNs) and longer follow-up is mandatory.

  14. Updated assessment of the six-minute walk test as predictor of acute radiation-induced pneumonitis

    International Nuclear Information System (INIS)

    Mao Jingfang; Zhang Junan; Zhou Sumin; Das, Shiva; Hollis, Donna R.; Folz, Rodney J.; Wong, Terence Z.; Marks, Lawrence B.

    2007-01-01

    Purpose: To assess the utility of the 6-minute walk test (6MWT) as a predictor of symptomatic radiation-induced pneumonitis (RP). Methods: As part of a prospective trial to study radiation-induced lung injury, 53 patients receiving thoracic radiotherapy (RT) underwent a pre-RT 6MWT, pulmonary function tests (PFTs), and had ≥3-month follow-up for prospective assessment of Grade 2 or worse RP (requiring medications or worse). Dosimetric parameters (e.g., the percentage of lung receiving ≥30 Gy) were extracted from the lung dose-volume histogram. The correlations between the 6MWT and PFT results were assessed using Pearson's correlation. The receiver operating characteristic technique was used in patient subgroups to evaluate the predictive capacities for RP of the dosimetric parameters, 6MWT results, and PFT results, or the combination (using discriminant analysis) of all three metrics. ROCKIT software was used to compare the receiver operating characteristic areas between each predictive model. The association of the decline in 6MWT with the development of RP was evaluated using Fisher's exact test. Results: The pre-RT PFT and 6MWT results correlated weakly (r = 0.44-0.57, p ≤ 0.001), suggesting that they measure somewhat different physiologic functions. Of the 53 patients, 9 (17%) developed RP. The dose-volume histogram-based dosimetric parameters were the best single-metric model for predicting RP (e.g., percentage of lung receiving ≥30 Gy, receiver operating characteristic area 0.73, p = 0.03). Including the PFT or 6MWT results with the percentage of lung receiving ≥30 Gy did not improve the predictions. The predictive abilities of dosimetric-based models improved when the analysis was restricted to those patients whose tumors were not causing regional lung dysfunction. No correlation was found between the decline in the 6MWT result and the RP rate (p = 0.6). Conclusion: Although the PFTs and 6MWT are related to each other, the correlation coefficients

  15. An end-to-end assessment of range uncertainty in proton therapy using animal tissues

    Science.gov (United States)

    Zheng, Yuanshui; Kang, Yixiu; Zeidan, Omar; Schreuder, Niek

    2016-11-01

    Accurate assessment of range uncertainty is critical in proton therapy. However, there is a lack of data and consensus on how to evaluate the appropriate amount of uncertainty. The purpose of this study is to quantify the range uncertainty in various treatment conditions in proton therapy, using transmission measurements through various animal tissues. Animal tissues, including a pig head, beef steak, and lamb leg, were used in this study. For each tissue, an end-to-end test closely imitating patient treatments was performed. This included CT scan simulation, treatment planning, image-guided alignment, and beam delivery. Radio-chromic films were placed at various depths in the distal dose falloff region to measure depth dose. Comparisons between measured and calculated doses were used to evaluate range differences. The dose difference at the distal falloff between measurement and calculation depends on tissue type and treatment conditions. The estimated range difference was up to 5, 6 and 4 mm for the pig head, beef steak, and lamb leg irradiation, respectively. Our study shows that the TPS was able to calculate proton range within about 1.5% plus 1.5 mm. Accurate assessment of range uncertainty in treatment planning would allow better optimization of proton beam treatment, thus fully achieving proton beams’ superior dose advantage over conventional photon-based radiation therapy.

  16. SU-E-T-128: Dosimetric Characteristics of Gafchromic EBT3 Films for Megavoltage Photon and Proton Beams.

    Science.gov (United States)

    Hayashi, N; Kato, H; Yada, R; Matsunaga, T; Ehara, I; Adachi, Y

    2012-06-01

    Gafchromic film for quantitative analysis was renewed from EBT2 to EBT3 film in November 2011. The purpose of this study is to investigate the relevant characteristics of EBT3 film for its application in dosimetric verification for IMRT/VMAT or proton therapy. We investigated the characteristics of EBT3 film with comparison of previous EBT2 film. The experiments in this study composed two categories. At first, the photo spectroscopy for the irradiated film was compared between EBT2 and EBT3. The film 1 day after the irradiation was analyzed by a photo spectrometer (SR520: JASCO Corporation, Japan). Secondly, we investigated several calibration curves which obtained by same batch. The films were calibrated by irradiation the films to 13 dose steps. The irradiated films were scanned by a flatbed scanner (ES-10000XL, Epson-Seiko Corporation, Japan). The difference on scan orientation was evaluated alternate portrait and landscape directions. The photon and proton beams were delivered from Clinac 21EX (Varian) and Mitsubishi machine, respectively. The peak absorption wavelength of EBT3 film and its response at all active range were basically same with that of EBT2 film. The peak wavelength of photo absorption in EBT3 was observed at 585 and 634 nm. The fog optical density was increased due to the hazy matte polyester for active layer. However, there is no change the tendency of the calibration curve responding to megavoltage photon and proton beams. The scan orientation dependency of EBT3 film was observed with similar to EBT2 film. The optical density of portrait orientation was 10% higher than that of landscape orientation. The dosimetric characteristics of EBT3 film were basically same with EBT2 film. With regard to the matte polyester, the creation of Newton's rings during scanning procedure was reduced. However, the suitable scan protocol should be used for accurate film dosimetry. © 2012 American Association of Physicists in Medicine.

  17. Dosimetric comparison between proton and photon beams in the moving gap region in cranio-spinal irradiation (CSI)

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Chee-Wai; Das, Indra J.; Zhao, Li; Wolanski, Mark; Johnstone, Peter A.S.; Buchsbaum, Jeffrey C. [IU Health Proton Therapy Center, Bloomington (United States); Dept. of Radiation Oncology, Indiana Univ. School of Medicine, Indianapolis (United States)], e-mail: ccheng1@iuhealth.org; Srivastava, Shiv P. [Dept. of Radiation Oncology, Indiana Univ. School of Medicine, Indianapolis (United States); Dept. of Radiation Oncology, Reid Hospital, Richmond (United States); Simmons, Joseph [IU Health Proton Therapy Center, Bloomington (United States)

    2013-04-15

    Purpose: To investigate the moving gap region dosimetry in proton beam cranio-spinal irradiation (CSI) to provide optimal dose uniformity across the treatment volume. Material and methods: Proton beams of ranges 11.6 cm and 16 cm are used for the spine and the brain fields, respectively. Beam profiles for a 30 cm snout are first matched at the 50% level (hot match) on the computer. Feathering is simulated by shifting the dose profiles by a known distance two successive times to simulate a 2 x feathering scheme. The process is repeated for 2 mm and 4 mm gaps. Similar procedures are used to determine the dose profiles in the moving gap for a series of gap widths, 0-10 mm, and feathering step sizes, 4-10 mm, for a Varian iX 6MV beam. The proton and photon dose profiles in the moving gap region are compared. Results: The dose profiles in the moving gap exhibit valleys and peaks in both proton and photon beam CSI. The dose in the moving gap for protons is around 100% or higher for 0 mm gap, for both 5 and 10 mm feathering step sizes. When the field gap is comparable or larger than the penumbra, dose minima as low as 66% is obtained. The dosimetric characteristics for 6 MV photon beams can be made similar to those of the protons by appropriately combining gap width and feathering step size. Conclusion: The dose in the moving gap region is determined by the lateral penumbras, the width of the gap and the feathering step size. The dose decreases with increasing gap width or decreasing feathering step size. The dosimetric characteristics are similar for photon and proton beams. However, proton CSI has virtually no exit dose and is beneficial for pediatric patients, whereas with photon beams the whole lung and abdomen receive non-negligible exit dose.

  18. SU-F-T-533: Study of Dosimetric Properties of Cadmium Free Alloy Used in Compensator Based IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, A [Dr B L Kapoor Hospital, New Delhi, Delhi (India); Kaushik, S [Dr B L Kapoor Hospital, New Delhi, Delhi (India); Guru Jambheshwar University of Science & Technology, Hisar, Haryana (India); Punia, R [Guru Jambheshwar University of Science & Technology, Hisar, Haryana (India); Singh, M [MMH College, Ghaziabad, Utter Pradesh (India)

    2016-06-15

    Purpose: To study the dosimetric properties of cadmium free alloy which is used in compensator based IMRT. Methods: A mixture of 30% of lead,52% of bismuth and 18% of tin was used to prepare alloy. We prepared slabs of different thicknesses ranging from 0.71 cm to 6.14 cm. Density of alloy was measured by Archimedes’ principle using SI-234 Denver instrument and water as buoyant liquid. Transmission, linear attenuation coefficient (µ), tissue phantom ration (TPR), beam hardening, surface dose (Ds), percentage depth dose (PDD) and effect of scatter were measured and analyze for different field size and different thickness of compensator for 6 MV photon beam. Measurements were carried out at 100 cm SSD and 160 cm SSD. Results: Density of alloy was found to be 9.5456 gm/cm3. Melting point of alloy is 90–95 °C. For a field size of 10×10 cm2 µ was 0.4253 cm-1 at 100 cm SSD. Calculated TPR was found to be within 3 % of measured TPR. Ds was found to be decreasing with increasing thickness of compensator. 1cm, 1.98 cm and 4.16 cm thick compensator slab decreased surface dose by 4.2%, 6.1% and 9.5% respectively for a field size of 10×10cm2 at 100 cm SSD. As field size increases Ds increases for a given compensator thickness. This is due to increase in amount of scattered dose from wider collimator opening. For smaller field size, PDDs are increased from 3.0% to 5.5% of open beam PDDs as compensator thickness increases from 1 cm to 6.14 cm at a depth of 10 cm in water. For larger field size variation in PDDs is not significant. Conclusion: High degree of modulation can be achieved from this compensator material, which is essential in compensator based IMRT. Dosimetric properties analyzed in this study establish this alloy as a reliable, cost effective, reusable compensator material.

  19. Dosimetric characteristics of methyl polymethacrylate (PMMA) commercially named as Clarex, for doses between 10 krad and 10 Mrad

    International Nuclear Information System (INIS)

    Castro Rubio Poli, D. de.

    1978-01-01

    The possibility to use the PMMA - commercially named as Clarex - for dosimetric control of industrial radiation process, taking advantage of the charges induced by ionizing radiation on the PMMA optical properties, was studied. Although theoretically other radiation effects could be eventually correlated with the dose absorbed in the PMMA (i.e., charge of mechanical or electrical properties) the dosimetric techniques based on the ultraviolet absorption spectrum modifications, near of visible region, have the advantage of their simplicity, swiftness and precision. A study on both the factors affecting the measurement reproducibility (temperature, humidity etc.) and some posterior effects that occur in the irradiated PMMA, has been acomplished. Other possible errors sources (sample thickness variation, spectrophotometer inaccuracy etc.) are also investigated. It has been concluded that the Clarex can be used as a good precision dosimeter within the interval of approximately 10 krad to 10 Mrad by measuring the optical density changes around 315 nm, provided some care is taken during handling. (Author) [pt

  20. Physical-dosimetric enabling a dual linear accelerator 3D planning systems for radiotherapy

    International Nuclear Information System (INIS)

    Alfonso, Rodolfo; Martinez, William; Arelis, Lores; Morales, Jorge

    2009-01-01

    The process of commissioning clinical linear accelerator requires a dual comprehensive study of the therapeutic beam parameters, both photons Electron. All information gained by measuring physical and dosimetric these beams must be analyzed, processed and refined for further modeling in computer-based treatment planning (RTPS). Of professionalism of this process will depend on the accuracy and precision of the calculations the prescribed doses. This paper aims to demonstrate availability clinical linear accelerator system-RTPS with late radiotherapy treatments shaped beam of photons and electrons. (author)