WorldWideScience

Sample records for dosemeter designs based

  1. Design and validation of a single sphere multi-detector neutron spectrometer based on LiF: Mg,Cu,P thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gomez-Ros, Jose Maria; Bedogni, Roberto; Moraleda, Montserrat; Romero, Ana; Delgado, Antonio; Esposito, Adolfo

    2010-01-01

    This communication describes a new neutron spectrometer consisting of pairs of 7 Li and 6 Li based thermoluminescent dosemeters (MCP-6, MCP-7) located at selected positions within a single moderating polyethylene sphere. The spatial arrangement of the dosemeters has been designed using the MCNPX Monte Carlo code to calculate the response matrix in order to obtain a nearly isotropic response for neutrons in the energy range up to 20 MeV. A partial validation of the calculated response matrix has been performed with the calibrated 241 Am-Be neutron source at the INFN-LNF Laboratory, using the shadow cone technique.

  2. Electronic personal dosemeters

    International Nuclear Information System (INIS)

    Marshall, T.O.; Bartlett, D.T.; Burgess, P.H.; Cranston, C.S.; Higginbottom, D.J.; Sutton, K.W.

    1990-01-01

    Personal dosimetry services approved by their national authorities for category A workers, invariably use passive dosemeters incorporating photographic film or thermoluminescent detectors. However, the performance characteristics of electronic dosemeters has improved substantially over the past decade to such an extent that in the opening lecture of the Solid State Dosimetry Conference at Oxford in 1986 the development of an electronic 'smart card' based on a silicon detector was briefly discussed. This idea has been taken up and at least one development programme is in progress aimed at the production of an electronic dosemeter suitable for use as a legal device. The more important performance requirements of personal dosemeters for this purpose are discussed and the earlier electronic dosemeter designs and the latest devices under development to meet this specification are compared. (author)

  3. EURADOS intercomparisons on whole body and extremity dosemeters (2008–2009) – Results and comparison of different dosemeter designs

    International Nuclear Information System (INIS)

    Stadtmann, H.; Grimbergen, T.W.M.; Figel, M.; Romero, A.M.; Mcwhan, A.F.

    2011-01-01

    The EURADOS (European Radiation Dosimetry Group) working group (WG2) on Harmonisation of Individual Monitoring in Europe has shown that intercomparisons are fundamental for harmonisation of individual monitoring. As a result of these considerations, EURADOS started to prepare a series of continuous intercomparisons for individual monitoring services (IMS) in Europe. EURADOS has now successfully executed two intercomparison exercises, one for whole body dosemeters (2008) and one for extremity dosemeters (2009). Both exercises were performed without external funding, all costs being covered by the participants’ fees. More than 120 (!) different – mainly passive – dosimetry systems were tested from all over Europe until now and the results were analysed and compared. Although scientific studies were not the primary objective of these exercises specific additional information about the tested systems supplied by the participants for statistical analysis allows a detailed analysis of these results with respect to different parameters like dosemeter type, detector material, filter thickness or others design parameters. The influence of such parameters on the response values of the dosemeters is analysed and discussed in this paper. Both energy response as well as directional response for beta and photon radiation are considered. The influence of different design parameters e.g. detector material, is analysed by comparing the frequency distribution of the response values for different dosemeter groups. Pronounced differences for different detector materials (LiF:Mg,Ti, LiF:Mg,Cu,P and Li 2 B 4 O 7 /CaSO 4 ) were found. The paper gives a comprehensive overview on the performance of various European dosimetry services and the influence of the dosemeter design on the resulting response values.

  4. The former tests realized to a personal neutron dosemeter based on solid nuclear tracks detector

    International Nuclear Information System (INIS)

    Camacho, M.E.; Tavera, L.; Balcazar, M.

    1997-01-01

    Due to the increase in the use of neutron radiation a personal neutron dosemeter based on solid nuclear tracks detector (DSTN) was designed and constructed. The personal dosemeter design consists of three arrangements. The first one consists of a plastic nuclear tracks detector (LR115 or CR39) in contact with a LiF pellet. The second one is the same that above but it placed among two cadmium pellets and, the third one is formed by the alone detector without converter neither neutron absorber. The three arrangements are placed inside a plastic porta detector hermetically closed to avoid the bottom produced by environmental radon whichever both detectors (LR115 and CR39) are sensitive. In this work the former tests realized to that dosemeter are presented. (Author)

  5. Factors affecting polyamide prototypes design of Albedo dosemeters

    International Nuclear Information System (INIS)

    Martins, M.M.; Mauricio, C.L.P.; Fonseca, E.S.

    1996-01-01

    This work studies the most important factors which affect the response of albedo neutron dosemeters containing LiF TLDs with the aim to improve their sensitivity. It includes tests of thickness and shape of the polyamide moderator body prototypes, albedo window diameter and TLD position inside the moderator. Analyzing the results, an albedo neutron dosemeter prototype, B 4 C covered, was developed. The prototype has a response three times higher than the albedo dosemeter now in use in Brazil. (author)

  6. Development of CaSO4:Dy based ring dosemeter for extremity monitoring of radiation workers in India

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Meenal, P.; Bhagat, R.V.; Singh, R.; Kolambe, D.H.; Chougaonkar, M.P.; Sapra, B.K.

    2014-01-01

    Extremity dosemeters are required to be worn in cases where the dose to extremities is expected to be significantly greater than the dose to the whole body. In India, CaSO 4 :Dy based three element personnel monitoring TLD badge worn at chest and wrist level are used for whole body and extremity monitoring, respectively. Presently no official/legal finger dosemeter is available for extremity monitoring for radiation workers in the country. To cater to the long standing requirement of finger dosimeter, a new compact three-element Extremity Ring Badge Dosemeter (ERBD) has been developed for measurement of the equivalent doses received by the extremities of radiation workers in terms of operational quantity Hp(0.07). It was aimed to meet the performance requirement of IEC/ISO standards. This paper gives the design detail and result of experimental studies of ERB dosemeter

  7. Results of the EURATOM programme for comparison of individual dosemeters

    International Nuclear Information System (INIS)

    Julius, H.W.

    1976-01-01

    The results of the EURATOM dosemeter comparison-program for dosemeters used in the member states are given. Especially the results obtained in the Netherlands are examined and evaluated. The design and characteristics of the badge developed by the TNO-RD which are based on a thermoluminescent dosemeter are given

  8. Personal neutron diode dosemeter

    International Nuclear Information System (INIS)

    Barthe, J.; Lahaye, T.; Moiseev, T.; Portal, G.

    1993-01-01

    The control and management of neutron doses, received by workers in nuclear power or research facilities, requires a knowledge of cumulated dose equivalent or dose equivalent rate in real time. Individual dosemeters so far developed for this purpose are scarce and not very satisfactory. Passive dosemeters such as TLD systems based on the albedo effect, nuclear emulsions or solid track detectors, do not give sufficiently accurate measurements. Furthermore, the increase in the quality factor and the more restrictive new ICRP recommendations diminish the maximum admissible threshold making currently used systems obsolete. Other than bubble dosemeter systems, based on thermodynamic effects of a superheated gel, no simple electronic device is available at the present time. The development of diode based dosimetric gamma badges, having a size similar to that of credit cards, has stimulated us to design and develop a personal neutron dosemeter based on a double diode system. The results obtained are very encouraging and practical models should become available in the near future. (author)

  9. A low-cost personal dosemeter based on optically stimulated luminescence (OSL) of common household salt (NaCl)

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2016-01-01

    Salt represents a radiation sensitive material that can be used for dosimetry. The objective of this experimental study was to test a low-cost salt dosemeter that was designed for personnel that are not radiation workers, but can operate in low probability events resulting in a serious external radiation exposure. The dosemeter is based on use of optically stimulated luminescence (OSL) of a common household salt. Attention was concentrated on its energy and angular responses. The dosemeter was fixed to the ICRU slab phantom and irradiated by photons of reference radiation qualities (ISO 4037-1) with mean energies between 33 and 1250 keV. Angular response was investigated for angles of incidence from 0° to 80° for radiation qualities of N-150 (∼118 keV) and S-Cs (∼662 keV). Single-Aliquot Regenerative-dose analytical protocol was employed for dose reconstruction. The results were evaluated with respect to H_p(10) measurement. The salt dosemeter can provide reliable or reasonably conservative H_p(10) estimates in radiation fields where photon energies > 100 keV predominate, radiation incidence angles are from 0° to 80° and also for rotational geometry. Furthermore, a personal dose reconstruction trial was demonstrated. Relative deviation between the measured and reference H_p(10) values was 5.5%. A practical disadvantage of the method is the more demanding analytical protocol. - Highlights: • Common salt has a considerable potential for dosimetry based on use of OSL. • A simple salt personal dosemeter was designed and tested. • Photon energy and angular responses were satisfactory for purposes of accidental dosimetry. • Dose reconstruction trial proved the potential for reliable estimate of personal doses.

  10. Feasibility of a neutron detector-dosemeter based on single-event upsets in dynamic random-access memories

    International Nuclear Information System (INIS)

    Phillips, G.W.; August, R.A.; Campbell, A.B.; Nelson, M.E.; Guardala, N.A.; Price, J.L.; Moscovitch, M.

    2002-01-01

    The feasibility was investigated of a solid-state neutron detector/dosemeter based on single-event upset (SEU) effects in dynamic random-access memories (DRAMs), commonly used in computer memories. Such a device, which uses a neutron converter material to produce a charged particle capable of causing an upset, would be light-weight, low-power, and could be read simply by polling the memory for bit flips. It would have significant advantages over standard solid-state neutron dosemeters which require off-line processing for track etching and analysis. Previous efforts at developing an SEU neutron detector/dosemeter have suffered from poor response, which can be greatly enhanced by selecting a modern high-density DRAM chip for SEU sensitivity and by using a thin 10 B film as a converter. Past attempts to use 10 B were not successful because the average alpha particle energy was insufficient to penetrate to the sensitive region of the memory. This can be overcome by removing the surface passivation layer before depositing the 10 B film or by implanting 10B directly into the chip. Previous experimental data show a 10 3 increase in neutron sensitivity by chips containing borosilicate glass, which could be used in an SEU detector. The results are presented of simulations showing that the absolute efficiency of an SEU neutron dosemeter can be increased by at least a factor of 1000 over earlier designs. (author)

  11. Feasibility study of extremity dosemeter based on polyallyl-diglycol-carbonate (CR-39) for neutron exposure

    International Nuclear Information System (INIS)

    Chau, Q.; Bruguier, P.

    2007-01-01

    In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyl-diglycol-carbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces. (authors)

  12. GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHOD.

    Science.gov (United States)

    Oda, K; Nakayama, T; Umetani, K; Kajihara, M; Yamauchi, T

    2016-09-01

    A novel technique for designing a radiator suitable for personal neutron dosemeter based on plastic track detector was discussed. A multi-layer structure has been proposed in the previous report, where the thicknesses of plural polyethylene (PE) layers and insensitive ones were determined by iterative calculations of double integral. In order to arrange this procedure and make it more systematic, unfolding calculation has been employed to estimate an ideal radiator containing an arbitrary hydrogen concentration. In the second step, realistic materials replaced it with consideration of minimisation of the layer number and commercial availability. A radiator consisting of three layers of PE, Upilex and Kapton sheets was finally designed, for which a deviation in the energy dependence between 0.1 and 20 MeV could be controlled within 18 %. An applicability of fluorescent nuclear track detector element has also been discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Performance tests on the NRPB thermoluminescent dosemeter

    CERN Document Server

    Shaw, K B

    1977-01-01

    Performance tests on the thermoluminescent dosemeter, designed at NRPB for use in the automated personal dosimetry system, are described. An ultra-thin lithium borate dosemeter has been developed for skin absorbed dose measurement. The X-ray, gamma-ray and beta-ray energy response of the dosemeter has been investigated and the angular response for the dosemeter has been examined. The annealing, read-out and stabilisation procedures for the dosemeter are described.

  14. Acid dip for dosemeter

    International Nuclear Information System (INIS)

    Stewart, J.C.; McWhan, A.F.

    1982-01-01

    Background signal in a PTFE based dosemeter caused by impurities in the PTFE and in the active component such as lithium fluoride is substantially reduced by treating the dosemeter with acid. The optimum treatment involves use of hydrofluoric acid at room temperature for approximately one minute, followed by thorough washing with methanol, and finally drying. This treatment is best applied after the original manufacture of the dosemeters. It may also be applied to existing dosemeters after they have been in use for some time. The treatment produces a permanent effect in reducing both the light induced signal and the non-light induced signal. The process may be applied to all types of dosemeter manufactured from PTFE or other plastics or resins which are able to resist brief exposure to acid. The treatment works particularly well with dosemeters based on PTFE and lithium fluoride. It is also applicable to dosemeters based on calcium sulphate, lithium borate and magnesium borate. Acids which may be used include hydrofluoric, hydrochloric, nitric, phosphoric and sulphuric. (author)

  15. Performance tests of a CaSO4:Dy based thermoluminescence personal dosemeter

    International Nuclear Information System (INIS)

    Azorin, J.; Gutierrez, A.; Niewiadomski, T.

    1986-01-01

    In order to replace LiF commercial thermoluminescence dosemeters (TLDs) now used in personnel monitoring, we developed a TLD personnel monitoring badge based on pellets of CaSO 4 :Dy bound in pure KBr placed in plastic holders provided with 0.8 mm Pb filters to compensate for the energy dependence of CaSO 4 :Dy. Performance tests, based on the proposals of international standards for TLDs intended to be used as general deep tissue personal dosemeters, were done by developing the detailed test methods both for the tests required by the International Atomic Energy Agency (fading, linearity, effect of fluorescent light and sunlight and stability under standard climatic conditions) and to meet the requirements of the International Electrotechnical Commission (batch homogeneity, detection threshold, stability of zero point repeatibility and residual). Initial tests showed a high residual and an increase of inhomogeneity. However, these drawbacks were overcome by changing the annealing procedure and the readout conditions. Using these new conditions TLDs met all the requirements for personal dosemeters. (author)

  16. Cr-39 fast neutron dosemeter based on A (n, α) converter

    International Nuclear Information System (INIS)

    Widayati, S.; Budiantari, T.

    1998-01-01

    The aim of this experiment is to obtained the response of Cr-39 as fast neutron dosemeter based on an (n, α) converter. Cr-39 was irradiated to AmBe fast neutron flux from 0.10 mSv to 2.5 mSv. Cr-39 processed by chemical etching with NaOH 20 % at temperature of 60 oC in six hours. The results of experiment showed that the response of Cr-39 based on an (n, α) converter is 6 times bigger than the response of Cr-39 without (n, α) converter. (author)

  17. Neutron dosimetry inside the containment building of Spanish nuclear power plants with PADC based dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Fuste, M.J. [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Domingo, C., E-mail: carles.domingo@uab.ca [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Amgarou, K.; Bouassoule, T.; Castelo, J. [Grup de Fisica de les Radiacions. Departament de Fisica. Edifici C. Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain)

    2009-10-15

    The Spanish Nuclear Safety Council (Consejo de Seguridad Nuclear, CSN) recommends performing neutron individual dose assignments at workplaces based on ambient dose equivalent measurements using area monitors and by estimating the amount of time that workers spend in the different monitored environments. In addition, some Spanish nuclear power plants estimate the neutron dose equivalent using albedo thermoluminescence dosemeters (TLD). In the period 2004-2006, our group, together with other research centers, participated in a project, funded by the CSN, with the support of the Spanish Nuclear Power Plants Association (UNESA), to investigate in situ which could be the best practical procedure for individual neutron dose monitoring in nuclear power plants. As part of this survey, several units of the UAB PADC based neutron dosemeter were exposed, on a methacrylate phantom simulating a human body, at four different places inside the containment building of the Asco I nuclear power plant. The influence of different types of calibration neutron fields is analysed and the dose equivalent for each point is estimated.

  18. The former tests realized to a personal neutron dosemeter based on solid nuclear tracks detector; Primeras pruebas realizadas a un dosimetro personal de neutrones basado en detectores solidos de trazas nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, M.E.; Tavera, L.; Balcazar, M. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    Due to the increase in the use of neutron radiation a personal neutron dosemeter based on solid nuclear tracks detector (DSTN) was designed and constructed. The personal dosemeter design consists of three arrangements. The first one consists of a plastic nuclear tracks detector (LR115 or CR39) in contact with a LiF pellet. The second one is the same that above but it placed among two cadmium pellets and, the third one is formed by the alone detector without converter neither neutron absorber. The three arrangements are placed inside a plastic porta detector hermetically closed to avoid the bottom produced by environmental radon whichever both detectors (LR115 and CR39) are sensitive. In this work the former tests realized to that dosemeter are presented. (Author)

  19. The NRPB nuclear emission dosemeter

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Bird, T.V.; Miles, J.C.H.

    1980-03-01

    The NRPB nuclear emulsion dosemeter is designed such that the thermal neutron response is similar to the fast neutron response. This report gives details of the dependence of response on incident neutron energy and on neutron angle of incidence. (author)

  20. Passive dosemeter

    International Nuclear Information System (INIS)

    Hassib, G.; Piesch, E.

    1981-01-01

    The dosemeter will be used for the detection of radon and thoron as well as their daughter products. It consists of two chambers with nuclear trace or alpha detectors. Both chambers are connected with one another at their front sides with a filter arranged in between. One of the chambers has got lateral openings, it is used as a diffusion chamber. In the other chamber exclusively radon and thoron are detected. (DG) [de

  1. A new electret dosemeter for radiotherapy

    International Nuclear Information System (INIS)

    Rodrigues, L.N.

    1985-01-01

    The results obtained with a new plane electret dosemeter for use in Radiotherapy are presented. The working principle of the electret dosemeter in based on the use of the electret field the ion collecting field, similarly to an ionization chamber, and as charge integrator detector. The dosemeter had, initialy, a cylindrical geometry. The results attained with it's calibration curve concerning the sensitivity, the stability and the reproducibility lead to changes in the dosemeter geometry. A plane geometry dosemeter was built in order to increase the useful exposure range. The plane dosemeter sensitivity dependence was measured versus the electret charging conditions, the chamber volume and wall material (aluminium, brass and stainless steel). The stainless steel dosemeter showed the best results. This dosemeter has the following characteristics: sensitivity 10 -13 C/R, volume 0.20 cm 3 . Compared to the Baldwin-Farmer dosemeter, this results are fairly good. A multiple electret dosemeter was developed to monitor the uniformity of the radiation beam for a Cobalt Teletherapy unit. The intercomparasion with the Baldwin-Farmer unit presented a maximum variation of 3%. (author) [pt

  2. Study of radioactive sources accumulation with application of thermoluminescence dosemeters on the base of alkaline earth metals sulfates

    International Nuclear Information System (INIS)

    Tokbergenov, I.; Sadykov, T.

    2001-01-01

    Methodic for study of accumulation and distribution of radioactive sources in a nature objects is developed. An essence of the method consists of in that quantity of accumulated radioactive sources in a nature objects is defining by absorption dose measured with help of thermoluminescent dosemeters on the base of alkaline earth metals sulfates such as CaSO 4 :Dy and SrSO 4 :Eu

  3. A personal radon dosemeter

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-03-01

    In the last decade the radon issue has become one of the major problems of radiation protection. Animal studies as well as epidemiological studies showed an increased lung cancer risk. A new personal radon-dosemeter on the basis of a CR-39 (poly-allyl diglycol carbonate) track-etch detector has been developed. The read-out of the detectors is based on the image- processing technique. The actual efficiency of the new dosemeter, obtained with a semi-automatic personal-computer based image-analysis system, is 1.43 +/- 0.15 tracks/cm 2 /(kBq/m 3 h), which is about three times that of the widely used Karlsruhe-type detector based on polycarbonate detectors

  4. Eurados trial performance test for personal dosemeters for external beta radiation

    DEFF Research Database (Denmark)

    Christensen, P.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU...... the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test....

  5. Calibration of PADC-based neutron area dosemeters in the neutron field produced in the treatment room of a medical LINAC

    International Nuclear Information System (INIS)

    Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; García-Fusté, M.J.; San-Pedro, M. de; Tana, L.; D’Errico, F.; Ciolini, R.; Di Fulvio, A.

    2013-01-01

    PADC-based nuclear track detectors have been widely used as convenient ambient dosemeters in many working places. However, due to the large energy dependence of their response in terms of ambient dose equivalent (H ∗ (10)) and to the diversity of workplace fields in terms of energy distribution, the appropriate calibration of these dosemeters is a delicate task. These are among the reasons why ISO has introduced the 12789 Series of Standards, where the simulated workplace neutron fields are introduced and their use to calibrate neutron dosemeters is recommended. This approach was applied in the present work to the UAB PADC-based nuclear track detectors. As a suitable workplace, the treatment room of a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa), was chosen. Here the neutron spectra in two points of tests (1.5 m and 2 m from the isocenter) were determined with the INFN-LNF Bonner Sphere Spectrometer equipped with Dysprosium activation foils (Dy-BSS), and the values of H ∗ (10) were derived on this basis. The PADC dosemeters were exposed in these points. Their workplace specific H*(10) responses were determined and compared with those previously obtained in different simulated workplace or reference (ISO 8529) neutron fields. - Highlights: ► The neutron field of a medical LINAC was used to calibrate PADC neutron dosemeters. ► The neutron spectra were derived with a Dy-foil based Bonner Sphere Spectrometer. ► Workplace specific calibration factor were derived for the PADC dosemeters. ► These factors were compared with those obtained in reference neutron fields

  6. Calibrations of pocket dosemeters using a comparison method

    International Nuclear Information System (INIS)

    Somarriba V, I.

    1996-01-01

    This monograph is dedicated mainly to the calibration of pocket dosemeters. Various types of radiation sources used in hospitals and different radiation detectors with emphasis on ionization chambers are briefly presented. Calibration methods based on the use of a reference dosemeter were developed to calibrate all pocket dosemeters existing at the Radiation Physics and Metrology Laboratory. Some of these dosemeters were used in personnel dosimetry at hospitals. Moreover, a study was realized about factors that affect the measurements with pocket dosemeters in the long term, such as discharges due to cosmic radiation. A DBASE IV program was developed to store the information included in the hospital's registry

  7. Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C

    DEFF Research Database (Denmark)

    Marckmann, C.J.; Andersen, C.E.; Aznar, M.C.

    2006-01-01

    Optical fibre dosemeter systems based on radioluminescence and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al2O3:C) crystals were developed for in vivo real-time dose rate and absorbed dose measurements in radiotherapy and mammography. A technique was also developed...... for making ultra-small dosemeter probes that can easily be placed inside patients in radiation treatment. These probes have shown excellent properties in both head and neck intensity-modulated radiation therapy treatment and in mammography. The dose-response of the OSL signal for the new optical fibre...

  8. The design and implementation of the DIRK system for dosemeter issue and record keeping

    CERN Document Server

    Kendall, G M; Kay, P; Law, D V; Salmon, L; Saw, G M A

    1983-01-01

    DIRK, the computerised system which the National Radiological Protection Board employs for its Personal Monitoring Service, is described. DIRK is also used to store the data for the National Registry for Radiation Workers and could support the Central Index of Dose Information should this be set up. The general principles of the design of DIRK, as well as a detailed description of the system, are included in the report. DIRK is based on a set of interlocked index sequential files manipulated by PL/1 programs. Data compaction techniques are used to reduce by a factor of ten the size of the files stored on magnetic disk. Security of the database is most important and two levels of security have been implemented. Table driven techniques are used for updating the database. A specially designed free-format language is used for specifying changes. Statistics, sorted listings of selected data and summaries are provided by a general purpose program for this type of operation. However, it has still been necessary to w...

  9. The design and implementation of the DIRK system for dosemeter issue and record keeping

    International Nuclear Information System (INIS)

    Kendall, G.M.; Kay, P.; Saw, G.M.A.; Salmon, L.; Carter, C.D.; Law, D.V.

    1983-05-01

    DIRK, the computerised system which the National Radiological Protection Board employs for its Personal Monitoring Service, is described. DIRK is also used to store the data for the National Registry for Radiation Workers and could support the Central Index of Dose Information should this be set up. The general principles of the design of DIRK, as well as a detailed description of the system, are included in the report. DIRK is based on a set of interlocked index sequential files manipulated by PL/1 programs. Data compaction techniques are used to reduce by a factor of ten the size of the files stored on magnetic disk. Security of the database is most important and two levels of security have been implemented. Table driven techniques are used for updating the database. A specially designed free-format language is used for specifying changes. Statistics, sorted listings of selected data and summaries are provided by a general purpose program for this type of operation. However, it has still been necessary to write a number of special purpose programs for some particular needs of DIRK users. The final section of the report describes the experiences gained during the planning, implementation and maintenance of DIRK. The importance of liaison with the eventual users of the system is emphasised. (author)

  10. Quality control for dosemeters

    International Nuclear Information System (INIS)

    Di Prinzio, R.

    1988-01-01

    Several tests and intercomparison of the secondary standard dosemeter calibration in Rio de Janeiro are described. Periodical tests, such as leakage current and the comparison between the secondary standard dosemeter in Rio de Janeiro e Sao Paulo are shown. (E.G.) [pt

  11. Calibration of a special neutron dosemeter based on solid-state track detectors and fission radiators in various neutron fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Krusche, M.; Schuricht, V.

    1980-01-01

    The calibration of a personnel neutron dosemeter in different neutron fields is described. The badge-like dosemeter contains 5 detectors: polycarbonate foil (10 μm, Makrofol KG), 232 Th, natural uranium, natural uranium with boron, and natural uranium with cadmium. Detector sensitivity and calibration factors have been calculated and measured in radiation fields of 252 Cf fission neutrons, WWR-S reactor neutrons with and without Cd and Fe shielding, 3-MeV (d,t) generator neutrons, and 238 PuBe neutrons. Measurement range and achievable accuracy are discussed from the point of view of applying the dosemeter in routine and emergency uses

  12. Alarm personal dosemeter

    International Nuclear Information System (INIS)

    Nunomiya, Tomoya; Yamauchi, Hideshi; Shibata, Tetsuo

    2007-01-01

    Fuji Electric advanced the development of the conventional alarm personal dosemeter (APD) by adopting JIS Z 4312 (2002), which reflects IEC61526 (1998), and by improving the radiation performance characteristics, electromagnetic performance characteristics and mechanical performance characteristics of the APD (acquiring a CE marking). This new dosemeter will target overseas market in the future. The APD is a suitable dosemeter for detecting and monitoring radiation exposure to personnel working in the controlled areas of nuclear facilities, such as nuclear power stations. The APD product line includes 'gamma ray', 'gamma ray + beta ray' and 'gamma ray + neutron' models. (author)

  13. Prediction analysis of dose equivalent responses of neutron dosemeters used at a MOX fuel facility

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.

    2011-01-01

    To predict how accurately neutron dosemeters can measure the neutron dose equivalent (rate) in MOX fuel fabrication facility work environments, the dose equivalent responses of neutron dosemeters were calculated by the spectral folding method. The dosemeters selected included two types of personal dosemeter, namely a thermoluminescent albedo neutron dosemeter and an electronic neutron dosemeter, three moderator-based neutron survey meters, and one special instrument called an H p (10) monitor. The calculations revealed the energy dependences of the responses expected within the entire range of neutron spectral variations observed in neutron fields at workplaces. (authors)

  14. Calibration procedures for mammography dosemeters in Poland

    International Nuclear Information System (INIS)

    Gwiazdowska, B.; Ulkowski, P.; Tolwinski, J.; Bulski, W.

    2002-01-01

    Breast cancer is the most frequent tumour in women and the effectiveness of the treatment depends dramatically on the early detection of the disease. That is the reason why in Poland the mammography control examinations are strongly supported by the Centre of Oncology. In Poland there are over 400 mammography units which account for about 300,000 examinations per year. An investigation performed by the Medical Physics Department of the Centre of Oncology in Warsaw at about 100 mammography facilities proved that in most cases the doses absorbed by the patients could be reduced without decrease of image quality. This is one of the reasons why the Polish Secondary Standard Dosimetry Laboratory (SSDL) dealing mainly with calibration of radiotherapy dosemeters is extending its activities and therefore new facilities and equipment adapted for calibration of mammographic dosemeters have been installed. The mammography dosimetry calibration equipment is permanently installed in the same laboratory room where the radiotherapy dosemeters are calibrated. A base of a mammography unit no longer in clinical use, together with its movable system has been adapted to handle ionization chamber holders. An X-ray tube with a 50 kV high frequency generator was also installed. The tube, a Varian type OEG-50-2, (designed for laboratory applications) with molybdenum anode of an anode angle 23,7 deg. and with a large focus, effective size approximately 5 mm 2 , has an inherent filtration of 0,25 mm beryllium. It is installed in a housing with 2mm lead shielding; a cone shaped beam is formed by a system of three collimators

  15. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  16. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  17. Comparison test of electronic dosemeters

    International Nuclear Information System (INIS)

    Butterweck, G.; Zimmerli, H.P.; Wernli, C.

    2001-01-01

    To assist with a planned purchase of electronic dosemeters by the Swiss Federal Office for Civil Protection, the calibration laboratory of the Paul Scherrer Institute performed tests on 11 types of electronic dosemeters manufactured by 10 European and American companies. The technical specifications for the World Trade Organisation (WTO) tendering procedure were largely in accord with the specifications of the international standard IEC 61526. First tests were performed with samples from each type of dosemeter. The reproducibility of a dose of 0.1 mSv generated with 137 Cs radiation at a dose rate of 2.1 mSv.h -1 was found adequate for all tested dosemeter types. The response for environmental levels of radiation showed a large variation, indicating insufficient background correction of some dosemeters. A very high dose rate of 10 Sv.h -1 provoked faulty dose readings for more than half of the tested dosemeters. Dosemeter response for low-energy photon radiation was satisfactory for two of the tested dosemeter types. Four dosemeter types were selected for extended technical tests. Three samples of each of these dosemeter types were purchased. For drop and temperature tests the specifications of the WTO tendering procedure outranged the specification of the IEC standard. Whereas even at a temperature of -25 deg. C the tested dosemeters functioned normally, drops from a height of 2 m onto a wooden surface rendered the samples of two dosemeter types inoperative. (author)

  18. A new, passive dosemeter for gamma, beta and neutron radiations

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L A; Stokes, R P, E-mail: rpstokes@dstl.gov.uk [Defence Science and Technology Laboratory, Environmental Sciences Department, Alverstoke, Gosport, Hants, PO12 2DL (United Kingdom)

    2011-03-01

    The Defence Science and Technology Laboratory (Dstl) provides personal radiation dosimetry to the UK Ministry of Defence. Dstl has recently developed a dosemeter that is based on a combination of thermoluminescent and etched-track detectors. The Dstl Combined Dosemeter is capable of assessing doses due to photons, beta particles and neutrons. This paper presents the laboratory type testing results for the Combined Dosemeter, and also describes the procedure for calibrating the dosemeter for use in workplace neutron fields. The Combined Dosemeter meets the type test requirements that are relevant to its intended applications, and gives neutron doses that are within 50% of the true dose in the workplaces in which it is used, even when the wearer has the potential to be exposed to a variety of neutron spectra (e.g. on board nuclear-powered submarines).

  19. A new, passive dosemeter for gamma, beta and neutron radiations

    International Nuclear Information System (INIS)

    Jones, L A; Stokes, R P

    2011-01-01

    The Defence Science and Technology Laboratory (Dstl) provides personal radiation dosimetry to the UK Ministry of Defence. Dstl has recently developed a dosemeter that is based on a combination of thermoluminescent and etched-track detectors. The Dstl Combined Dosemeter is capable of assessing doses due to photons, beta particles and neutrons. This paper presents the laboratory type testing results for the Combined Dosemeter, and also describes the procedure for calibrating the dosemeter for use in workplace neutron fields. The Combined Dosemeter meets the type test requirements that are relevant to its intended applications, and gives neutron doses that are within 50% of the true dose in the workplaces in which it is used, even when the wearer has the potential to be exposed to a variety of neutron spectra (e.g. on board nuclear-powered submarines).

  20. Calibration of farmer dosemeters

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Anwar, K.; Arshed, W.; Mubarak, M.A.; Orfi, S.D.

    1984-08-01

    The Farmer Dosemeters of Atomic Energy Medical Centre (AEMC) Jamshoro were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) at PINSTECH, using the NPL Secondary Standard Therapy level X-ray exposure meter. The results are presented in this report. (authors)

  1. Dosimetric characteristics of a TLD dosemeter with extremities

    International Nuclear Information System (INIS)

    Molina P, D.; Diaz B, E.; Lien V, R.

    1999-01-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm 3 covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  2. The new IRSN passive dosemeter using the RPL technique

    International Nuclear Information System (INIS)

    Fraboulet, P.; Cale, E.; Itie, C.; Bottollier-Depois, Jean-Francois

    2008-01-01

    Full text: The Institute for Radiological Protection and Nuclear Safety (IRSN) is the French public organisation in charge of research and expertise into nuclear safety and radiation protection. IRSN provides also services in these areas like dosimetric survey for 150,000 workers liable to be exposed to ionising radiation. At present whole-body dosemeters provided by the IRSN laboratory for photons and beta-particles are based on photographic films. In order to anticipate likely supplying decrease and to improve the service, IRSN has decided to replace photographic films by dosemeters based on the radio-photoluminescence (RPL) technology, supplied by the Japanese Company Chiyoda Technol. RPL was chosen after a thorough comparison with other available passive techniques (thermoluminescent dosemeters: TLD, and optically stimulated luminescence: OSL). Constraints due to large-scale production of dosemeters (packaging, shipping, etc.) were taken into account as well. Irradiation tests for five different dosemeters, based on the 3 available techniques (TLD, OSL, RPL) were performed. The main results of these tests are presented (energy, dose and angular response, detection threshold, etc.) together with main technical characteristics of the new RPL dosemeter (range in energy and dose, homogeneity, reproducibility, re-reading, information about radiation type from reading, etc.). This dosemeter is expected to give significative improvements in the IRSN laboratory's provision of service thanks to better dosimetric performances and because it offers the possibility to get information to analyse over-exposure circumstances. (author)

  3. Principle and use of dosemeters

    International Nuclear Information System (INIS)

    Genet, S.; Ribaud, I.

    1997-01-01

    The institute of nuclear physics of Orsay is accepted by the Ministry of Labour to insure the surveillance of workers individual external exposure against the danger of ionizing radiations and to execute monitoring of radiation protection. The dosemeters studied in this report are the photographic film dosemeters ( for x rays, gamma rays and beta - rays), the trace detectors (fast neutrons) and the radio thermo luminescent dosemeters. For each type, the principle and how to use it are given. (N.C.)

  4. Using operational equipment to read accident dosemeters.

    Science.gov (United States)

    Devine, R T; Vigil, M M; Martinez, W A

    2004-01-01

    Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

  5. Electret dosemeter for beta radiation

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    The response characteristics of an electret dosemeter for beta radiation are studied. Experiments were performed using different geometries and walls, and it was verified for which geometry the dosemeter sensitivity is greater. Sources of 90 Sr - 90 Y, 204 Tl and 85 Kr were used in the experiments. (I.C.R.) [pt

  6. Automated read-out of thermoluminescence dosemeters in a centralized individual monitoring service

    International Nuclear Information System (INIS)

    Toivonen, M.

    The organizational problems in maintaining centralized individual monitoring service with erasable and re-usable dosemeters are evaluated. Design criteria for an automated thermoluminescence reader are laid down. It is characteristic for the planning of the monitoring system that the issuing of dosemeters can be arranged without having two dosemeters for each worker. A home made reader designed to fullfil these criteria is presented. The use of a standard barcode and a standard optical barcode reader in identification of dosemeters is described. A method of using a minicomputer in preparing the self-fastening identification labels, in printing mailing lists and in printing results is described

  7. Characterisation of a Personal TL Photon Dosemeter Based on Two LiF(Mg,Cu,P) Detectors in Terms of Hp(0.07,alpha) and Hp(10,alpha)

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Monteventi, F.; Sermenghi, I.; Uleri, G.

    1999-01-01

    A study was undertaken to evaluate the response of the ENEA Photon Personal Dosemeter, slightly modified in design, in terms of H p (0.07, α) and H p (10, α). A filtration of 20 and 270 mg.cm -2 respectively for the two LiF(Mg,Cu,P) detectors employed was adopted according to a preliminary analytical simulation. The new dosemeter can measure both H p (0.07, α) with a maximum uncertainty of ±4% in the range from 10 to 200 keV and H p (10, α) with a maximum uncertainty of ±15% in the range from 10 keV to 1.25 MeV, using the detector responses together with a correction function with respect to their ratio. Moreover, tests were performed to evaluate the dosemeter angular response (0 deg., 20 deg., 40 deg., and 60 deg.) obtaining good results according to international recommendations. All irradiation tests were performed at SSL of ENEA Institute for Radiation Protection in Bologna using the ISO water phantom (30 x 30 x 15 cm 3 ) and standard ISO filtered X ray beams as well as 137 Cs and 60 Co sources. This work represents a preliminary type test of the ENEA photon personal dosemeter and allows its introduction in routine dosimetry practice in accordance with the ICRU reference quantities. (author)

  8. Mobile-Dose: A Dose-Meter Designed for Use in Automatic Machineries for Dose Manipulation in Nuclear Medicine

    Science.gov (United States)

    de Asmundis, Riccardo; Boiano, Alfonso; Ramaglia, Antonio

    2008-06-01

    Mobile-Dose has been designed for a very innovative use: the integration in a robotic machinery for automatic preparation of radioactive doses, to be injected to patients in Nuclear Medicine Departments, with real time measurement of the activity under preparation. Mobile-Dose gives a constant measurement of the dose during the filling of vials or syringes, triggering the end of the filling process based on a predefined dose limit. Several applications of Mobile-Dose have been delivered worldwide, from Italian hospitals and clinics to European and Japanese ones. The design of such an instrument and its integration in robotic machineries, was required by an Italian company specialised in radiation protection tools for nuclear applications, in the period 2001-2003. At the time of its design, apparently no commercial instruments with a suitable interfacing capability to the external world existed: we designed it in order to satisfy all the strict requirements coming from the medical aspects (precision within 10%, repeatability, stability, time response) and from the industrial conceiving principles that are mandatory to ensure a good reliability in such a complicated environment. The instrument is suitable to be used in standalone mode too, thanks to its portability and compactness and to the intelligent operator panel programmed for this purpose.

  9. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  10. Optical readout method for solid-state dosemeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Eichner, F.N.; Stahl, K.A.; Miller, S.D.

    1986-07-01

    The readout of solid-state dosemeters is usually accomplished by heating to produce thermoluminescence. This technique has several disadvantages including stressing the dosemeter crystals, melting Teflon enclosures, and destroying the thin dosemeters designed for beta particle measurements. An optical readout method is being developed to avoid these difficulties. Standard dosemeters were irradiated to a dose of approximately 0.02 Sv with 137 Cs gamma rays. The dosemeters were then irradiated with light produced by a high-intensity xenon lamp. Various wavelength bands, from the ultraviolet through the visible and to the near-infrared, were used. The degree of trap emptying was found to be proportional to the total optical power incident. With the intensities used in the preliminary experiments, over 90% trap emptying was achieved. This new technique will prove useful for dosemeters that are encased in plastic for automatic processing. The details of this optical readout method, along with some possible applications in neutron and beta dosimetry are described. 7 refs., 3 figs

  11. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  12. The MCNP-4C2 design of a two element photon/electron dosemeter that uses magnesium/copper/phosphorus doped lithium fluoride.

    Science.gov (United States)

    Eakins, J S; Bartlett, D T; Hager, L G; Molinos-Solsona, C; Tanner, R J

    2008-01-01

    The Health Protection Agency is changing from using detectors made from 7LiF:Mg,Ti in its photon/electron personal dosemeters, to 7LiF:Mg,Cu,P. Specifically, the Harshaw TLD-700H card is to be adopted. As a consequence of this change, the dosemeter holder is also being modified not only to accommodate the shape of the new card, but also to optimize the photon and electron response characteristics of the device. This redesign process was achieved using MCNP-4C2 and the kerma approximation, electron range/energy tables with additional electron transport calculations, and experimental validation, with different potential filters compared; the optimum filter studied was a polytetrafluoroethylene disc of diameter 18 mm and thickness 4.3 mm. Calculated relative response characteristics at different angles of incidence and energies between 16 and 6174 keV are presented for this new dosemeter configuration and compared with measured type-test results. A new estimate for the energy-dependent relative light conversion efficiency appropriate to the 7LiF:Mg,Cu,P was also derived for determining the correct dosemeter response.

  13. Two miniature electronic dosemeters Yperwatch - Gamcard

    International Nuclear Information System (INIS)

    Clavel, B.; Jaillon, J.

    1993-01-01

    Yperwatch and Gamcard were miniature electronic gamma personal dose and dose rate monitors. The Yperwatch is mounted in a wristwatch and the Gamcard in a case of the size of a standard credit card. The technology provides users with all the performance of a standard professional electronic dosemeter (integrated dose, dose rate, audible alarms, time in use). Yperwatch and Gamcard are based on well-proven electronic dosimetry technology, but with a greater ease of use. (author)

  14. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  15. Study of a solid state micro-dosemeter based on a monolithic silicon telescope: Irradiations with low-energy neutrons and direct comparison with a cylindrical TEPC

    International Nuclear Information System (INIS)

    Agosteo, S.; Colautti, P.; Fanton, I.; Fazzi, A.; Introini, M. V.; Moro, D.; Pola, A.; Varoli, V.

    2011-01-01

    A silicon device based on the monolithic silicon telescope technology coupled to a tissue-equivalent converter was proposed and investigated for solid state microdosimetry. The detector is constituted by a DE stage about 2 μm in thickness geometrically segmented in a matrix of micrometric diodes and a residual-energy measurement stage E about 500 μm in thickness. Each thin diode has a cylindrical sensitive volume 9 μm in nominal diameter, similar to that of a cylindrical tissue-equivalent proportional counter (TEPC). The silicon device and a cylindrical TEPC were irradiated in the same experimental conditions with quasi-monoenergetic neutrons of energy between 0.64 and 2.3 MeV at the INFN-Legnaro National Laboratories (LNLINFN, Legnaro (Italy)). The aim was to study the capability of the silicon-based system of reproducing microdosimetric spectra similar to those measured by a reference micro-dosemeter. The TEPC was set in order to simulate a tissue site about 2 μm in diameter. The spectra of the energy imparted to the ΔE stage of the silicon telescope were corrected for tissue-equivalence through an optimized procedure that exploits the information from the residual energy measurement stage E. A geometrical correction based on parametric criteria for shape-equivalence was also applied. The agreement between the dose distributions of lineal energy and the corresponding mean values is satisfactory at each neutron energy considered. (authors)

  16. EURADOS intercomparison 2012 for neutron dosemeters

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Chevallier, M.A.; Cruz-Suarez, R.; Luszik-Bhadra, M.; Mayer, S.; Thomas, D.J.; Tanner, R.; Vanhavere, F.

    2014-11-01

    dosimetric systems are based. A few participants reported poor results for all irradiation fields, some reported poor results only for some fields. A meeting was held during the 12 th Neutron and Ion Dosimetry Symposium (NEUDOS-12, held in June 2013 in Aix-en-Provence, F) to allow the participants to discuss general aspects of this intercomparison and specific systems problems with the OG. The intercomparison results can assist participants in showing compliance with their quality management systems. They allow comparisons of individual results with those of other participants and, if required, help in developing action plans for improving their systems. IC2012n was the first EURADOS organized intercomparison exercise for neutron dosemeters. It is an important action because international neutron dosimetry intercomparisons have been performed only every 8-10 years.

  17. EURADOS intercomparison 2012 for neutron dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA-Radiation Protection Institute, Bologna (Italy); Chevallier, M.A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France); Cruz-Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Mayer, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Thomas, D.J. [National Physical Laboratory (NPL), Teddington (United Kingdom); Tanner, R. [Public Health England, Oxon (United Kingdom); Vanhavere, F. [SCK-CEN, Belgian Nuclear Research Centre, Mol (Belgium)

    2014-11-15

    principle on which the dosimetric systems are based. A few participants reported poor results for all irradiation fields, some reported poor results only for some fields. A meeting was held during the 12{sup th} Neutron and Ion Dosimetry Symposium (NEUDOS-12, held in June 2013 in Aix-en-Provence, F) to allow the participants to discuss general aspects of this intercomparison and specific systems problems with the OG. The intercomparison results can assist participants in showing compliance with their quality management systems. They allow comparisons of individual results with those of other participants and, if required, help in developing action plans for improving their systems. IC2012n was the first EURADOS organized intercomparison exercise for neutron dosemeters. It is an important action because international neutron dosimetry intercomparisons have been performed only every 8-10 years.

  18. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of electret dosemeter to slow neutrons exposure is cited, mentioning the preparation and the irradiation of dosemeter with Am-Be source. Some theory considerations about the response of electret dosemeter to slow and fast neutrons are also presented. (C.G.C.) [pt

  19. A portable versatile x-and γ-ray dosemeter with digital display for medical use

    International Nuclear Information System (INIS)

    Sankaran, A.; Gangadharan, P.

    1980-01-01

    A multipurpose dosemeter based on analogue-to-digital (A-D) conversion has been developed using solid state devices, micropower integrated circuits and displays. The A-D converter combines the features of a MOSFET electrometer, a voltage-to-frequency converter, the automatic Townsend balance, LED(LCD) display for exposure, analogue output and has a voltage-measuring accuracy of +-O.1% FS+-1 digit. The dosemeter which is designed to measure a wide range of X- and γ-ray exposure rates (1 mRh -1 to 1000 R min -1 ) and exposures (1 mR to 1000 R) with a variety of air-equivalent ionisation chambers, is compact, rugged and battery or AC mains powered. It is designed to provide trouble-free performance, easy operation and maintenance and to be independent of climatic conditions. Combining the features of a survey meter, dosemeter and a radioisotope calibrator, it can be fabricated using the facilities locally available in hospitals or universities. (author)

  20. Specification for personal photographic dosemeters

    International Nuclear Information System (INIS)

    1981-01-01

    The 1981 British/International Standard Specification, prepared under the direction of the Nuclear Engineering Standards Committee and TC85 of the International Organization for Standardization, is described for personal photographic dosemeters. The Standard specifies classification, characteristics and test procedures to determine absorbed doses due to X or gamma radiations (energy less than 3 MeV) and absorbed doses due to beta radiation (max. energy 0.6 to 3 MeV), whether or not accompanied by X, gamma or bremsstrahlung photon radiation. The Standard is particularly applicable to dosemeters intended to be carried on the chest or wrist. (U.K.)

  1. Improvement of the calibration technique of clinical dosemeters

    International Nuclear Information System (INIS)

    Ehlin Caldas, L.V.

    1988-08-01

    Clinical dosemeters constituted of ionization chambers connected to electrometers are usually calibrated as whole systems in appropriate radiation fields against secondary standard dosemeters in calibration laboratories. This work reports on a technique of component calibration procedures separately for chambers and electrometers applied in the calibration laboratory of IPEN-CNEN, Brazil. For electrometer calibration, redundancy was established by using a standard capacitor of 1000pF (General Radio, USA) and a standard current source based on air ionization with Sr 90 (PTW, Germany). The results from both methods applied to several electrometers of clinical dosemeters agreed within 0.4%. The calibration factors for the respective chambers were determined by intercomparing their response to the response of a certified calibrated chamber in a Co 60 calibration beam using a Keithley electrometer type 617. Overall calibration factors compared with the product of the respective component calibration factors for the tested dosemeters showed an agreement better than 0.7%. This deviation has to be considered with regard to an uncertainty of 2.5% in routine calibration of clinical dosemeters. Calibration by components permits to calibrate ionization chambers one at a time for those hospitals who have several ionization chambers but only one electrometer (small hospitals, hospitals in developing countries). 6 refs, 2 figs, 2 tabs

  2. Development and testing of a thermoluminescent dosemeter for mixed neutron-photon-beta radiation fields

    International Nuclear Information System (INIS)

    Zummo, J.J.; Liu, J.C.

    1998-08-01

    A new four-element thermoluminescent (TL) dosemeter and dose evaluation algorithm have been developed and tested to better characterize personnel exposure in mixed neutron-photon-beta radiation fields. The prototype dosemeter is based on a commercially available TL card (with three LiF-7 chips and one LiF-6 chip) and modified filtration elements. The new algorithm takes advantage of the high temperature peak characteristics of the LiF-6 element to better quantify the neutron dose component. The dosemeter was tested in various radiation fields, consisting of mixtures of two radiation types typically used for dosemeter performance testing, as well as mixtures of three radiation types to simulate possible exposure conditions. The new dosemeter gave superior performance, based on the tolerance levels, when using the new algorithm as compared to a conventional algorithm that did not use the high temperature peak methodology. The limitations and further improvements are discussed

  3. Neutron dosemeter responses in workplace fields and the implications of using realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Thomas, D.J.; Horwood, N.; Taylor, G.C.

    1999-01-01

    The use of realistic neutron calibration fields to overcome some of the problems associated with the response functions of presently available dosemeters, both area survey instruments and personal dosemeters, has been investigated. Realistic calibration fields have spectra which, compared to conventional radionuclide source based calibration fields, more closely match those of the workplace fields in which dosemeters are used. Monte Carlo simulations were performed to identify laboratory systems which would produce appropriate workplace-like calibration fields. A detailed analysis was then undertaken of the predicted under- and over-responses of dosemeters in a wide selection of measured workplace field spectra assuming calibration in a selection of calibration fields. These included both conventional radionuclide source calibration fields, and also several proposed realistic calibration fields. The present state of the art for dosemeter performance, and the possibilities of improving accuracy by using realistic calibration fields are both presented. (author)

  4. Australian participation in international intercomparisons of environmental dosemeters

    International Nuclear Information System (INIS)

    Boas, J.F.; David, R.C.; Jones, J.

    2002-01-01

    The Environmental Measurements Laboratory of the U.S. Department of Energy has conducted international intercomparisons of environmental dosemeters at regular intervals since 1974. This paper reports the results obtained in the 10th and 11th intercomparisons by JFB and JGY at the Australian Radiation Laboratory (in 1992 and 1996 respectively) and in the 12th intercomparison by JFB and DRCT at the Australian Radiation Protection and Nuclear Safety Agency and by JGY and JJ at Australian Radiation Serviceces during 2000 and 2001. The ARL/ARPANSA measurements used a simple dosemeter holder containing two CaSO 4 :Dy impregnated Teflon discs, one unshielded and the other shielded by approximately 2.4 mm of Cu. The ARS measurements used a commercially available TLD badge case containing a CaSO 4 :Dy impregnated Teflon card. The commercial badge case was not symmetrical in design. The filtration in the front and rear sections of the commercial badge case varied from an open area to an area shielded by copper, tin and cadmium. The results obtained were generally within ±15% of the reference values measured by EML using high-pressure ionisation chambers for dosemeters exposed hi the field to environmental radiation and for dosemeters given a single exposure to 137 Cs or 241 Am at EML or an associated laboratory. Similar agreement was obtained for dosemeters exposed in the field and also given a single exposure to 137 Cs radiation. In order to obtain this measure of agreement, the dosemeters were individually calibrated and the readouts corrected for fading. Copyright (2002) Australasian Radiation Protection Society Inc

  5. Dosimetric characteristics of a TLD dosemeter with extremities; Caracteristicas dosimetricas de un dosimetro TLD de extremidades

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Diaz B, E.; Lien V, R. [Centro de Proteccion e Higiene de las Radiaciones, CPHR, Apdo.Postal 6195, Habana 6, CP 10600, Ciudad Habana (Cuba)

    1999-07-01

    It was designed a TLD dosemeter for the monitoring of the extremities. This one consists in a metallic ring with a circular orifice where is arranged a T L detector of LiF: Mg,Ti (Model JR1152C) 5 x 5 x 0.8 mm{sup 3} covered by a polyethylene fine layer. In this work were studied the dosimetric properties of the dosemeter for its application in the dosimetry of extremities for photonic radiation. the results obtained allow conclude that the designed dosemeter can be used for the extremities monitoring. (Author)

  6. Dosimertry characteristics and performance comparisons: Environmental radiophotoluminescent glass dosemeters versus thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Lee, J.H.; Lin, M.S.; Hsu, S.M.; Chen, I.J.; Chen, W.L.; Wang, C.F.

    2009-01-01

    This paper describes the dosimetry characteristic comparison of environmental radiophotoluminescent glass dosemeter (RPLGD) and thermoluminescent dosemeter (TLD) systems employed at the Institute of Nuclear Energy Research (INER, Taiwan). The luminescence centers of TLD disappeared by reading process, and repetition of measurement is impossible. RPLGDs can be repeatedly read and keep the luminescence centers for a long time. The RPLGD fading is about 1% within 30 days after being exposed to ionizing radiation. Environmental cumulative doses measured by a RPLGD and a TLD were compared at the same monitoring points of INER during two years. The sensitivity of TLD decreased with gradual loss due to fading at higher temperatures. The difference between results obtained by RPLGD and TLD is discussed mainly with respect to the dependence on the ambient temperature. In addition, this research also refers to the American National Standard Institute (ANSI) Draft Standard N13.29 (1996) to organize the environmental dosimetry performance tests of the INER's RPLGDs and the TLDs. The results mean that both kinds of dosemeters can meet the performance test criteria. An accreditation procedure for the institutes which provide the environmental dosimetry services in Taiwan was suggested based on the comparison results of these two dosimetry systems

  7. Technical specification of the NRPB Nuclear Emulsion Dosemeter

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Bird, T.V.

    1978-08-01

    This document is a formal specification of the NRPB Nuclear Emulsion Dosemeter. The dosemeter specified in this report replaces the NRPB Fast Neutron Personal Dosemeter specified in NRPB-R50. (author)

  8. Selected references on thermoluminescent dosemeters for personnel monitoring

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-08-01

    This bibliography contains references on: specific thermoluminescent dosemeters used for personnel dosimetry; comparisons of thermoluminescent and other dosemeters for personnel monitoring and read-out apparatus for thermoluminescent dosemeters. An appendix contains selected foreign language references. (author)

  9. A study of the irradiation temperature coefficient for L-alanine and DL-alanine dosemeters

    International Nuclear Information System (INIS)

    Desrosiers, M. F.; Lin, M.; Cooper, S. L.; Cui, Y.; Chen, K.

    2006-01-01

    Alanine dosimetry is now well established both as a reference and routine dosemeter for industrial irradiation processing. Accurate dosimetry under the relatively harsh conditions of industrial processing requires a characterisation of the parameters that influence the dosemeter response. The temperature of the dosemeter during irradiation is a difficult quantity to measure so that the accuracy of the temperature coefficient that governs the dosemeter response becomes a critical factor. Numerous publications have reported temperature coefficients for several types of alanine dosemeters. The observed differences in the measured values were commonly attributed to the differences in the polymer binder or the experimental design of the measurement. However, the data demonstrated a consistent difference in the temperature coefficients between L-alanine and DL-alanine. Since there were no commonalities in the dosemeter composition or the measurement methods applied, a clear conclusion is not possible. To resolve this issue, the two isomeric forms of alanine dosemeters were prepared and irradiated in an identical manner. The results indicated that the DL-alanine temperature coefficient is more than 50% higher than the L-alanine temperature coefficient. (authors)

  10. A neutron dosemeter for nuclear criticality accidents.

    Science.gov (United States)

    d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.

  11. A neutron dosemeter for nuclear criticality accidents

    International Nuclear Information System (INIS)

    D'Errico, F.; Curzio, G.; Ciolini, R.; Del Gratta, A.; Nath, R.

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photo microsensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc (France)). The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets. (authors)

  12. A gamma/neutron-discriminating, Cooled, Optically Stimulated Luminescence (COSL) dosemeter

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.

    1992-07-01

    The Cooled Optically Stimulated Luminescence (COSL) of CaF 2 :Mn (grain sizes from 0.1 to 100 microns) powder embedded in a hydrogenous matrix is reported as a function of fast-neutron dose. When all the CaF 2 :Mn grains are interrogated at once, the COSL plastic dosemeters have a minimum detectable limit of 1 cSv fast neutrons; the gamma component from the bare 252 cf exposure was determined with a separate dosemeter. We report here on a proton-recoil-based dosemeter that generates pulse height spectra, much like the scintillator of Hornyak, (2) to provide information on both the neutron and gamma dose

  13. Radiological environmental monitoring with LiF-700-H dosemeters

    International Nuclear Information System (INIS)

    Scarnichia, E.; Levanon, I.; Andres, P.; Miani, C.; Ramirez, S.

    2011-10-01

    Since 2008 a radiological environmental monitoring with LiF-700-H has been carried out as a result of increasing the Ra-6 research reactor core power. The information obtained is used to evaluate and to quantify analytically the air kerma rate, the fading and the associated uncertainty by developing software tools (deconvolution and uncertainty algorithms). LiF-700-H dosemeters were chosen because of their high sensitivity to low air kerma rates. They show a very good stability and a negligible fading for two-month working periods. The air kerma rate detection limit (based on the 3σ criterion) during these working periods is about 0.4 n Gy/h. Air kerma rates of about 70 n Gy/h are measured with this detection limit. Following the Nist guidelines, an algorithm was developed in order to find the associated uncertainty. It considers several aspects, such as the source activity decay, distance source-dosemeter during the calibration procedure, irradiation time, calibration factor, dosemeter readout, dosemeter sensitivity, TLD reader stability and fading. The associated uncertainty is found to be about 25% for a 95% confidence interval (k = 2.025), which can be considered acceptable when taking into account the very low air kerma rates estimated. The LiF-700-H response to different energies and its relationship with climate changes over the calendar year are planned as future tasks. (Author)

  14. A contribution to thermoluminescence dosemeter system optimisation applied to environmental monitoring around nuclear power plants

    International Nuclear Information System (INIS)

    Dies, X.; Ortega, X.; Rosell, J.

    1990-01-01

    The factors that constitute a thermoluminescence dosimetric system have been studied and optimised, with the intention of defining strategies for improving precision and accuracy of TL dosimetry systems for environmental monitoring. An optimisation technique based on fractional factorial designs permitted a reduction in the number of necessary experiments and clarified interactions between various factors. The model for fading over time showed that TL response in LiF:Mg,Ti dosemeters was independent of time between irradiation and readout, and this was applied to fading corrections in nuclear power plant environmental monitoring. (author)

  15. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of the electret dosemeter to exposition of slow neutrons is studied. Different external coatings are used on the dosemeter (polyethylene, alminium, polyethylene + boron, aluminium + boron) and exposure curves (with and without water) are compared. (M.A.C.) [pt

  16. Development trends of radiophotoluminescent glass dosemeter

    International Nuclear Information System (INIS)

    Ikegami, T.

    2004-01-01

    RPL glass dosemeter has been recently recognized to have a good performance as accumulation dosemeter and has been routinely used for personal dosimetry and environmental radiation monitoring. Furthermore, its applicable field is being extending to medical radiation measurement. The history of RPL glass dosemeter is very long. It was born in USA in 1950s and after that it was improved in Japan. And it was used as personal dosemeter in 1970s. But, in those days, RPL glass dosemeter was not suitable to low dose measurement due to some handling problems. So, its use had been reduced gradually. The author has broken through any past problems, by mainly realizing the pulsed UV excitation method. In this paper, the development history, principle and features, and the development good results of the pulsed UV excitation method are summarized, including the introduction of recent RPL glass dosimetry products. (author)

  17. Fast neutron sensitivity of polymer dosemeters

    International Nuclear Information System (INIS)

    Harper, M.W.; Pearson, D.W.; Moran, P.R.

    1975-01-01

    The responses of polymer thermocurrent dosemeters to fission spectrum and 14 MeV neutrons were measured. The dosemeters are in the form of disks 1 cm diam by 0.5 mm thick. Relative to Cobalt 60 gamma responses, teflon PTFE dosemeters show a 6 percent response to 14 MeV neutrons and a 5 percent response to fission neutrons on a tissue rad basis. Polymethylpentene dosemeters show a 49 percent response to 14 MeV neutrons and a 40 percent response to fission neutrons on a tissue rad basis when provided with adequate recoil proton buildup. The sensitivity of these dosemeters is limited to neutron doses greater than 10 rads by spurious background currents

  18. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  19. Study and determination of thermoluminescent properties of a new dosemeter based on α -Al2O3:C

    International Nuclear Information System (INIS)

    Rivera Montalvo, T.

    1993-01-01

    Study and determination of the thermoluminescent properties of a new dosimeter based on α -Al 2 O 3 :C. Dosimetric characteristics studied were: glow curve structure, sensitivity, reproducibility, TL response as function of dose, and fading. Each experimental data point represents the average value of at least five measurements. The new detectors exhibited two peaks in its glow curve at 383 and 493 K. The low temperature peak decayed at room temperature in a few hours. Sensitivity of α -Al 2 O 3 :C detectors to gamma radiation per unit of absorbed dose was 3 times that of LiF:Mg, Cu, P and 11 times that of CaSO 4 : Dy + PTFE; the last two detectors possess characteristics which make them appropriate for diverse applications in the field of radiation dosimetry, specially for environmental measurements. (Author)

  20. Calibration of thermoluminescence skin dosemeter response to beta emitters found in Ontario Hydro nuclear power stations

    International Nuclear Information System (INIS)

    Walsh, M.L.; Agnew, D.A.; Donnelly, K.E.

    1984-01-01

    The response of the Ontario Hydro Thermoluminescence Dosimetry System to beta radiation in nuclear power station environments was evaluated. Synthetic beta spectra were constructed, based on activity samples from heat transport systems and fuelling machine contamination smears at nuclear power stations. Using these spectra and dosemeter energy response functions, an overall response factor for the skin dosemeter relative to skin dose at 7 mg.cm -2 was calculated. This calculation was done assuming three specific geometries: (1) an infinite uniformly contaminated plane source at a distance of 33 cm (50 mg.cm -2 total shielding) from the receptor; (2) an infinite cloud surrounding the receptor; (3) a point source at 33 cm. Based on these calculations, a conservative response factor of 0.7 has been chosen. This provides an equation for skin dose assignment, i.e. Skin Dose = 1.4 x Skin Dosemeter Reading when the skin dosemeter is directly calibrated in mGy(gamma). (author)

  1. The right choice: extremity dosemeter for different radiation fields

    International Nuclear Information System (INIS)

    Brasik, N.; Stadtmann, H.; Kindl, P.

    2005-01-01

    Full text: Measurements of weakly penetrating radiation in personal dosimetry present problems in the design of suitable detectors and in the interpretation of their readings. For the measurement of the individual beta radiation dose, personal dosemeter for the fingers/tips are required. In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or the filter are too thick. TLDs of a standard thickness can seriously underestimate personal skin doses, especially in external fields of weakly penetrating radiation fields. LiF:Mg, Cu, P is a promising TL material which allows the production of thin detectors with sufficient sensitivity. Dosimetric properties of two different types of extremity dosemeters, designed to measure the personal dose equivalent Hp(0.07), have been compared: LiF:Mg, Ti (TLD100) and LiF:Mg, Cu, P (TLD700H). The first one consists of 100 mg.cm -2 LiF:Mg, Ti (TLD 100) chip and a 35mg. cm -2 cap, the other consists of a 7mg. cm -2 layer of LiF:Mg, Cu, P (TLD-700H) powder and a 5mg. cm -2 cap. The evaluation was done in two steps: performance tests (ISO-12794) and measurements in real workplaces. In the first step type test results for beta calibration were compared. In addition calibration for low energy photon radiation according to ISO 4037-3 was carried out. In the second step, simultaneous measurements with both types of dosemeters were performed at workplaces, where radiopharmaceuticals containing different radioisotopes are prepared and applied. Practices in these fields are characterized by handling of high activities at very small distances between source and skin. The results from the comparison of the two dosemeter types are presented and analyzed with respect to different radiation fields. Experiments showed a satisfactory sensitivity for the thinner dosemeter (TLD 700H) for detecting beta radiation at protection levels and a good

  2. New generation of ''legal'' dosemeters

    International Nuclear Information System (INIS)

    Fletcher, R.

    1991-01-01

    In the early 1980s research at the National Radiological Protection Board in the UK proved the feasibility of using solid state electronics in an entirely new dosimetry technology - capable of reaching right down into the low energy photon ranges, and able to detect beta radiation. In 1988 the NRPB undertook a joint venture with Siemens Plessey Controls to develop a marketable personal dosemeter meeting full Health and Safety Executive approval as a ''legal'' instrument. The Electronic Personal Dosemeter (EPD) was thus conceived, and will reach the pre-production stage early this year. The EPD makes use of state-of-the-art silicon integrated circuit technology, with a custom amplifier and microprocessor system. The liquid crystal display continuously shows the accumulated short-term penetrating dose in terms of the Hp (10) unit, and can also show superficial dose and dose rates. Because the EPD must be continuously powered, the custom lithium battery was commissioned to ensure a minimum service interval of 12 months. The EPD is the size and weight of a small pocket pager. Although dose data can be read directly from the EPD, a comprehensive data management system is needed to effect real-life use in industry. The EPD thus communicates by infra-red link to a reader unit which interfaces an IBM-compatible PC, allowing authorized personnel to read the dose memories and perform dose alarm threshold settings. (author)

  3. Individual monitoring with official electronic dosemeters in Germany - concepts and reality

    International Nuclear Information System (INIS)

    Martini, E.; Wahl, W.; Huebner, S.; Freynhagen, D.; Staemmler, M.

    2005-01-01

    Full text: Active (electronic) personal dosemeters (APD) are radiometers, which are equipped as active or passive dosimeters. They can directly indicate a dose rate and/or the dose integrated during a certain period (direct-indicating, active electronic personal dosemeters mentioned) or only over a separate reader (direct-selectable, passive electronic personal dosemeters mentioned). A concept is presented for the use of passive or active electronic personal dosemeters in Germany as official dosemeters, e.g. in hospitals. The concept features a net-based approach for secure data communication between readers for passive and active electronic personal dosemeters und the official personal dosimetry monitoring service(s), taking the German policies (StrISchV und RoeV in hospitals) into account. The net-based solution includes a processor controlled interface via TCP/IP connected to the dosimetry reader(s), und reader interfaces, an official interim data bank and all the necessary equipment such as PC, Raid-configuration, USV support, network connection and further details. Investigations have been started to achieve highest-level data manipulation security, data completeness und data correctness. (author)

  4. Passive neutron dosemeter with activation detector

    Energy Technology Data Exchange (ETDEWEB)

    Valero L, C.; Banuelos F, A.; Guzman G, K. A.; Borja H, C. G.; Hernandez D, V. M.; Vega C, H. R., E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    A passive neutron dosemeter with {sup 197}Au activation detector has been developed. The area dosemeter was made as a 20.5 {phi} x 20.5 cm{sup 2} polyethylene moderator, with a polyethylene pug where a {sup 197}Au foil can be located either parallel or perpendicular to moderator axis. Using Monte Carlo methods, with the MCNP5 code. With the fluence response and the fluence-to-equivalent dose conversion coefficients from ICRP-74, responses to H*(10) were also calculated, these were compared against responses of commercially available neutron area monitors and dosemeters. (Author)

  5. Application of radiophotoluminescence dosemeters for environmental monitoring

    International Nuclear Information System (INIS)

    Mihara, A.; Tamura, T.; Mochizuki, T.; Numakunai, T.; Yoshida, Y.; Ohi, Y.

    1993-01-01

    Feasibility study has been made on the radiofluorescence glass (RPL) dosemeters for environmental radiation monitoring. Main items in the laboratory tests are batch uniformities of pre-dose and sensitivity, build-up characteristics of RPL intensity, energy and angular responses, stabilities for RPL reading, anneal cycling and climatic conditional changes. We have determined self-irradiation dose and cosmic ray contribution. Radiation monitoring field test for the RPL dosemeters has been conducted in comparison with the present TLD systems. A procedure manual for the environmental monitoring by the use of RPL dosemeters is in preparation

  6. Colour dosemeters for high level radiation dosimetry

    DEFF Research Database (Denmark)

    Schönbacher, H.; Coninckx, F.; Miller, A.

    1990-01-01

    interpretation or a dose measurement with a simple instrument such as a portable reflecting densitometer in the range of 10(3) to 10(6) Gy. Two projects were investigated: (1) a thin plastic film with a self adhesive tape containing a radiochromic dye which induces a colour change when exposed to ionising...... of paint and film dosemeters were installed in the 450 GeV Super Proton Synchrotron (SPS) at CERN and irradiated during operation for more than two years. Within the useful range of the dosemeters, dose comparisons with other dosemeter types gave satisfactory results. Application in other fields...

  7. Study about the feasibility of using an electret dosemeter as a personal dosemeter

    International Nuclear Information System (INIS)

    Leitao, I.P.

    1983-01-01

    A feasibility study of the electret dosemeters as a personnel dosemeter was carried out. Preliminary tests were applied, in order to assess the dosemeter response to radiation, linearity, stability, reproductibility, direcional dependence and energy dependence in energy range from 33 to 1250 KeV. In general the results are in agreement with the recommendations of the Commision of the European Communities (CEC) for the use of this device as a personnel dosemeter with the exception of the energy dependence and the stability at medium term. (Author) [pt

  8. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter

    International Nuclear Information System (INIS)

    Chen, F.; Baffa, O.; Graeff, C.F.O.

    1998-01-01

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band (∼ 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  9. The need for comparison of diagnostic dosemeters

    International Nuclear Information System (INIS)

    Kramer, H.M.

    1989-01-01

    One precondition for successfully implementing quality control in diagnostic radiology is that the measuring instruments used are of adequate quality. Among the measuring instruments used for quality control, dosemeters play a predominant role. Therefore it is essential to know the performance characteristics of a suitable dosemeter and to have information on the uncertainties and measurement errors found during acceptance testing. An outline will be given of the requirements on the accuracy of dosemeters. Such requirements have to address the task of the dosemeter and also take into account their technical feasibility. In order to gather information on the performance characteristics of field instruments, a programme for a European intercomparison has been developed which was carried out in 1988. The programme, together with its underlying ideas and its objectives, is presented in this paper. (author)

  10. Glass as a gamma ray dosemeter

    International Nuclear Information System (INIS)

    Sutrisno Puspodikoro.

    1978-01-01

    The advantages of glass as a γ-rays dosemeter are studied. Experiments have shown that ordinary microscope object glass can be used as a dosemeter, which dose range for linear response extends from about 10 4 -10 6 rads. Heat treatment of the irradiated samples accelerates the initial fading of coloration and stabilizes the residual optical density. On the other side cooling of them retards the initial fading. (author)

  11. Evaluation of film dosemeters by linear programming

    International Nuclear Information System (INIS)

    Kragh, P.; Nitschke, J.

    1992-01-01

    An evaluation method for multi-component dosemeters is described which uses linear programming in order to decrease the dependence on energy and direction. The results of this method are more accurate than those obtained with the evaluation methods so far applied in film dosimetry. In addition, systematic errors can be given when evaluating individual measurements. Combined linear programming, as a special case of the presented method, is described taking a film dosemeter of particular type as an example. (orig.) [de

  12. Needle-type differential thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Kubu, M.

    1988-01-01

    The dosemeter serves to measure the depth distribution of absorbed dose in a phantom in mixed neutron and gamma radiation fields. It consists of a stratified cylindrical absorber in which alternate moderator and cadmium layers. Inside are two bores along the longitudinal axis for tubes filled with 6 LiF and 7 LiF powder thermoluminescent dosemeters. The device is easily portable and allows to carry out measurements with a high level of reproducibility. (J.B.). 4 figs

  13. Personnel monitoring of radiations with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The basics of personnel dosimetry technics, used by the Radiologic Protetion and Assessorie Service (SAPRA) are presented, consisting on use of thermoluminescent and CaSO 4 :Dy monitors in aggregated pellets by Teflon. The characteristics of this dosemeters, relating to the sensitivity, energetic dependence, spike temperature, characteristic emission curve, decay and light effect are shown. The thermoluminescent dosemeter measure system and the personnel monitoring system are also described. (C.G.C.) [pt

  14. Self-indicating radiation alert dosemeter (SIRAD)

    International Nuclear Information System (INIS)

    Riel, G. K.; Winters, P.; Patel, G.; Patel, P.

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident. (authors)

  15. Self-indicating radiation alert dosemeter (SIRAD).

    Science.gov (United States)

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  16. New KID dosemeter for measurement of cosmic dosimetry

    International Nuclear Information System (INIS)

    Peksova, D.; Kakona, M.; Krist, P.; Kocur, Z.; Larina, K. V.; Ploc, O.

    2018-01-01

    The KID dosemeter is a small semiconductor low-power detector developed for common use. The current design is special designed after measuring cosmic rays on aircraft decks. The design concept is the same world-class devices Internet of Things (IoT). As a detection element detector were tested three variants a) PIN HAMAMATSU S2744-09 photodiode, b) 9 parallel Vishay photodiodes TEMD5080X01, c) 16 Vishay photodiode TEMD5080X01 again in parallel connection. All variants are silicon PIN photodiode. (authors)

  17. Micro-dosemeter instrument (MIDN) for assessing risk in space

    International Nuclear Information System (INIS)

    Pisacane, V. L.; Dolecek, Q. E.; Malak, H.; Cucinotta, F. A.; Zaider, M.; Rosenfeld, A. B.; Rusek, A.; Sivertz, M.; Dicello, J. F.

    2011-01-01

    Radiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field. This micro-dosemeter-dosemeter nucleon instrument is for use in a space-suit, spacecraft, remote rover and other applications. It provides absorbed dose, dose rate and dose equivalent in real time so that action can be taken to reduce exposure. Such a system has applications in health physics, anti-terrorism and radiation-hardening of electronics as well. The space system is described and results of ground-based studies are presented and compared with predictions of transport codes. An early prototype in 2007 was successfully launched, the only solid-state micro-dosemeter to have flown in space. Published by Oxford Univ. Press on behalf of the US Government 2011. (authors)

  18. On the calibration of radiotherapy dosemeters in Australia

    International Nuclear Information System (INIS)

    Huntley, R.; Kotler, L.; Webb, D.

    2000-01-01

    Full text: Dosemeters for external beam radiotherapy are calibrated in Australia by ARPANSA, against the national primary standards of exposure and absorbed dose. The primary standards are free air chambers for exposure at low and medium energy X-rays, a graphite cavity chamber for exposure at 60 Co, and a graphite calorimeter for absorbed dose at 60 Co and high energy (MV) X -rays. Radiotherapy dosemeters are calibrated against these standards using a well documented formalism to provide calibration factors suitable for use with dosimetry protocols. A dosemeter usually comprises an ionization chamber connected to an independent electrometer. These are calibrated separately if possible. A combined calibration factor is reported together with the electrometer calibration factor (sensitivity). The dosimetry protocol used in radiotherapy centres in Australia and New Zealand is currently the simplified version of the IAEA TRS277 protocol, published by the New Zealand NRL and recommended by the ACPSEM. This protocol requires the use of an exposure or air kerma calibration factor at 60 Co (Nx or Nk) to evaluate the absorbed dose to air calibration factor N D . The chamber is then placed in a water phantom with its centre displaced from the reference point by p eff . ARPANSA can also supply calibration factors in absorbed dose to water (N D,w ), as required as input to the new IAEA CoP. If an absorbed dose to water calibration factor is used by the radiotherapy centre, the chamber should be placed with its centre at the reference point in the water phantom. ARPANSA has for some years coordinated the participation of Australian radiotherapy centres in the IAEA TLD Quality Audit service. Note that this service does not represent a calibration and should not be referred to as such. The only calibration is that provided by ARPANSA for a reference dosemeter at each radiotherapy centre. As soon as the ANSTO SSDL is operational, calibrations of reference dosemeters will also be

  19. Use of a robotic manipulator in the simulation of the automation of a calibration process of dosemeters

    International Nuclear Information System (INIS)

    Benitez R, J.S.; Najera H, M.C.

    2002-01-01

    The development of a system based in a manipulative robot which simulates the operative sequence in a calibration process of dosemeters is presented. In this process it is performed the monitoring of the dosemeter positions and the calibrator by mean of an arm of articulated robot which develops the movement sequences and the taking a decision based on the information coming from the external sensors. (Author)

  20. Radiofrequency detection by bubble dosemeter technology

    International Nuclear Information System (INIS)

    Olsen, R.G.

    1990-01-01

    In an initial attempt to utilise solid state dosimetric technology for non-ionizing radiation, planar bubble type detectors were irradiated with microwave energy at 2.38 GHz. Individual devices were produced as thin discs (8 cm diam. x 0.6 cm) rather than in the normal test-tube configuration. Both aqueous and non-aqueous-based devices were exposed to plane-wave irradiation inside a microwave anechoic chamber at power densities ranging from 40 to 80 mW.cm -2 . Specific absorption rate (SAR) in the disc shaped devices was thermometrically determined with the aid of a non-perturbing temperature probe and was approximately 0.3 (W.kg -1 )(mW.cm -2 ). Results showed the irradiation-induced bubble response to be relatively uniform in both types of devices, but the sensitivity was lower than that needed in a practical microwave dosemeter. We believe that improved sensitivity will be obtained by adding materials with a high microwave absorption cross section. (author)

  1. A new extremity dosemeter for beta and gamma radiation

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Pagenkamper, M.

    1988-01-01

    An extremity dosemeter developed at the Juelich Nuclear Research Centre is very well suited for the precise and energy-independent measurement of the skin dose generated by beta or gamma radiation. This is also confirmed by the results of this intercomparison programme. The dosemeter contains three TLDs of LiF in Teflon mounted behind a window of 0.9 mg/cm 2 . The great advantage of this dosemeter is three TLD's enabling statements about the radiation quality. However, the dosemeter has two disadvantages The dosemeter is complicated to manufacture. A very thin plastic foil of 0.9 mg/cm 2 must be attached to a support. This work is difficult and time-consuming and cannot be automated. The window in front of the TLD is not sturdy enough and is occasionally destroyed when the dosemeter is being worn. These two disadvantages prevent this extremity dosemeter from being used more frequently. For this reason, work was begun on developing a new extremity dosemeter without these two disadvantages. The great advantage of the previous dosemeter of obtaining statements about the type of radiation with the aid of readings from three TLD's was to be retained. The improved extremity dosemeter has a more sturdy and thicker window with a similar response as the previous dosemeter with a thinner window

  2. Unbiased metal oxide semiconductor ionising radiation dosemeter

    International Nuclear Information System (INIS)

    Kumurdjian, N.; Sarrabayrouse, G.J.

    1995-01-01

    To assess the application of MOS devices as low dose rate dosemeters, the sensitivity is the major factor although little studies have been performed on that subject. It is studied here, as well as thermal stability and linearity of the response curve. Other advantages are specified such as large measurable dose range, low cost, small size, possibility of integration. (D.L.)

  3. Contribution to the development of a fast neutron dosemeter SAD 1

    International Nuclear Information System (INIS)

    Jung, M.; Francois, H.; Heilmann, C.; Demoulin, R.; Kappler, A.; Oppel, R.

    1983-01-01

    The dosemeter response to various neutron fluxes from known monoenergetic sources has been calibrated in order to optimize this response, especially as regards the conversion factor for the hydrogeneous material used. Alongside these microscopic measurements, an automatic measuring system has been developed, based on detecting the amount of silver left along the tracks of recoil protons formed in (n,p) reactions. It is necessary to have a complete calibration of the converter response xsub(D), which is related directly to the energy loss in the emulsion. For this purpose we have designed an X-ray fluorescence apparatus which determines the residual silver by exciting the 22.5 and 25 keV lines of silver [fr

  4. One year of a thermoluminescent dosemeter and dose record keeping service

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1979-01-01

    A brief description is given of the National Radiological Protection Board's (NRPB) thermoluminescent dosemeter. The automated processing of these dosemeters is linked to a computer-based system of dose records. The postal system is currently used by about 10% of the establishments for which the NRPB provides a personnel monitoring service, but it will soon be extended to other establishments. The distributions of individual whole body doses in 1977 are tabulated. The significant advantage of this new system lies in the improvements in accuracy, completeness, and convenience to the employers of record keeping. (U.K.)

  5. Development of an improved dosemeter for assessments of risk to the eye

    International Nuclear Information System (INIS)

    Eakins, J.S.; Gilvin, P.J.; Hager, L.G.; Tanner, R.J.

    2014-01-01

    To develop an improved dosemeter to assess photon and beta exposures of the eye lens, and in response to issues surrounding the preferred values of H lens to be used for guiding operational radiation protection, a programme of re-optimization of the current PHE thermoluminescence dosemeter has been performed. In particular, refinements of the filter located in front of the sensitive 7 LiF:Mg,Cu,P element have been considered, so that the dose response characteristics of the device provide a better and more conservative estimate of risk. The investigation was performed using the Monte Carlo modelling software MCNP5, to produce a final design that featured a filter containing a 9.5 mm diameter polypropylene hemisphere truncated to a maximum thickness of 3.0 mm. The responses of this design in photon and electron fields are presented here, contrasted against those of the existing PHE eye dosemeter, with respect to the operational quantity H p (3,E,θ) and both current and suggested values for the absorbed dose per fluence risk profile for the lens of the eye. - Highlights: • A programme of re-optimization of the current PHE eye dosemeter has been performed. • A design featuring a truncated hemispherical filter was found to be optimal. • The shape of the filter better resembles the rotational profile of the eye. • Response characteristics depend on the calibration conditions taken to provide the best risk estimate

  6. Calibration of personal dosemeters for extremities of fields of radiation gamma

    International Nuclear Information System (INIS)

    Papadopulos, S.; Gregori, S.; Moreno, B.; Guillen, J.

    1998-01-01

    In this work the conversion factors are presented obtained experimentally of kerma in free air in equivalent dose H(d,O o ) in finger and in arm for fields of radiation gamma of normal incidence dosemeters of extremities was irradiated, based on detecting TL of LIF 7 (TLD-700, Harshaw), placed on the surface of the finger phantom and arm

  7. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  8. Energy dependence of pMOS dosemeters

    International Nuclear Information System (INIS)

    Savic, Z.; Stankovic, S.; Kovacevic, M.; Petrovic, M.

    1996-01-01

    The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using 60 Co and 137 Cs sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards. (Author)

  9. A personal dosemeter of radon daughter products

    International Nuclear Information System (INIS)

    Burian, I.; Richter, M.; Ochec, J.; Dohnal, J.

    1990-01-01

    The OD 88 personal dosemeter for radon daughter products uses an alpha particle track detector and is of active type, with forced air aspiration through the detecting system. The pumping device consists of a miniature membrane pump and an electronic speed controller. The air flow rate is little affected by normal changes in supply voltage and/or pneumatic resistance of the pump circuit. The dosemeter is embedded in a miner's lamp and is fed from its accumulator battery. The pumping device is activated as the lamp is taken out of the charger and deactivated as it is slid into the charger again. The dosemeter head accommodates an AFPC filter on which the radon daughter products deposit. The energy of the alpha particles is reduced by an air layer and a Makrofol decelerating foil. The particles hitting the detector give rise to defects with an intensity proportional to the total linear stopping power at the moment of incidence; ideal tracks 10 μm in size require incident energy of 1.1 to 1.3 MeV. The detector is replaced in a month and worked up in an etching vessel, making use of the higher solubility of the detecting layer of the foil in NaOH at the spot of the alpha particle incidence. (P.A.). 4 figs., 17 refs

  10. Participatory design based research

    DEFF Research Database (Denmark)

    Dau, Susanne; Bach Jensen, Louise; Falk, Lars

    This poster reveal how participatory design based research by the use of a CoED inspired creative process can be used for designing solutions to problems regarding students study activities outside campus.......This poster reveal how participatory design based research by the use of a CoED inspired creative process can be used for designing solutions to problems regarding students study activities outside campus....

  11. Field calibration of a TLD albedo dosemeter in the high-energy neutron field of CERF

    International Nuclear Information System (INIS)

    Haninger, T.; Kleinau, P.; Haninger, S.

    2017-01-01

    The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (CERN-EU high-energy Reference Field). This type of albedo dosemeter is based on thermoluminescent detectors (TLDs) and used by the individual monitoring service of the Helmholtz Zentrum Muenchen (AWST) since 2015 for monitoring persons, who are exposed occupationally against photon and neutron radiation. The motivation for this experiment was to gain a field specific neutron correction factor N n for workplaces at high-energy particle accelerators. N n is a dimensionless factor relative to a basic detector calibration with 137 Cs and is used to calculate the personal neutron dose in terms of H p (10) from the neutron albedo signal. The results show that the sensitivity of the albedo dosemeter for this specific neutron field is not significantly lower as for fast neutrons of a radionuclide source like 252 Cf. The neutron correction factor varies between 0.73 and 1.16 with a midrange value of 0.94. The albedo dosemeter is therefore appropriate to monitor persons, which are exposed at high-energy particle accelerators. (authors)

  12. The development of a personal dosemeter for use by aircraft crew

    International Nuclear Information System (INIS)

    Stokes, R.P.; Talbot, L.

    2000-01-01

    This paper describes preliminary work to develop a cosmic-radiation dosemeter for use by military aircraft crew. The dosemeter is based on a combination of CR-39 etched-track detectors and TLD-700 thermoluminescent detectors. It is intended that the CR-39 be used to assess the neutron dose, while the TLD-700 is used to assess the photon and charged particle dose. The sensitivity of CR-39 to the neutron component of cosmic radiation was estimated by irradiating samples of the plastic at the CERN-CEC High Energy Reference Field Facility. This facility produced a radiation field with a neutron spectrum resembling that of the neutron component of cosmic radiation a typical airflight altitudes. The response of the CR-39 was linear over the range of doses studied (0.2-6.0 mSv) and there was no significant fading in the six-month period after irradiation. The TLD-700 component of the dosemeter was calibrated using 137 Cs gamma rays. The response of the TLD-700 was linear over the range of doses studied (0-1.1 mSv) with no significant fade in the six-month period after irradiation. It was concluded that a combination of CR-39 and TLD-700 detectors would provide an effective cosmic-radiation dosemeter for use by military aircraft crew. (author)

  13. Dosemeter calibration in X-ray and in cobalt-60

    International Nuclear Information System (INIS)

    Silva, T.A. da

    1988-01-01

    Some tests about quality security for clinical dosemeter calibration in secondary standard dosimetry laboratory are described. The tests in gama calibration system, in X-ray calibration, in secondary standard dosimeter, in the dosemeter that will be calibrated, during the calibration and after the calibration are shown. (C.G.C.) [pt

  14. Comparing different error-conditions in film dosemeter evaluation

    International Nuclear Information System (INIS)

    Roed, H.; Figel, M.

    2007-01-01

    In the evaluation of a film used as a personal dosemeter it may be necessary to mark the dosemeters when possible error-conditions are recognised, such as errors that have an influence on the ability to make a correct evaluation of the dose value. In this project a comparison has been carried out to examine how two individual monitoring services, IMS [National Inst. of Radiation Hygiene (Denmark) (NIRH) and National Research Centre for Environment and Health (Germany) (GSF)], from two different EU countries mark their dosemeters. The IMS are different in size, type of customers and issuing period, but both use films as their primary dosemeters. The error-conditions examined are dosemeters exposed to moisture or light, contaminated dosemeters, films exposed outside the badge, missing filters in the badge, films inserted incorrectly in the badge and dosemeters not returned or returned too late to the IMS. The data are collected for the year 2003 where NIRH evaluated ∼50,000 and GSF ∼1.4 million film dosemeters. The percentage of film dosemeters is calculated for each error-condition as well as the distribution among eight different employee categories, i.e. medicine, nuclear medicine, nuclear industry, industry, radiography, laboratories, veterinary and others. It turned out, that incorrect insertion of the film in the badge was the most common error-condition observed at both IMS and that veterinarians, as the employee category, generally have the highest number of errors. NIRH has a significantly higher relative number of dosemeters in most error-conditions than GSF, which perhaps reflects that a comparison is difficult due to different systemic and methodical differences between the IMS and countries, e.g. regulations and monitoring programs etc. Also the non-existence of a common categorisation method for employee categories contributes to make a comparison like this difficult. (authors)

  15. Characteristics and performances of electronic personal dosemeters

    International Nuclear Information System (INIS)

    Aubert, B.

    2002-01-01

    The regulations have made obligation for 2 years to measure and analyse the amounts of radiations actually received during an operation. The whole of these measurements taken uninterrupted for an immediate reading is indicated like the operational dosimetry, which is carried out with the means of personal electronic dosemeters. This study analyses the legislation relating to this type of dosimetry as well as the requirements in medical environment, and presents an assessment of the characteristics and performances of the devices available on the French market at the beginning of 2002 starting from the information provided by the various manufacturers. (author)

  16. Individual dosemeter with ionization chamber for intervention

    International Nuclear Information System (INIS)

    Prigent, M.

    1982-01-01

    The altogether intervention ratemeter-dosemeter is a device for work condition control and for dosimetry of intervention gang in hostile medium. A portable irradiation marker with ionization chamber either carried by staff, either put at the work post, delivers an information function of the surrounding irradiation field in which moves the intervention staff. The information is processed so as the absorbed dose rate and the absorbed dose are given simultaneously. The connection between the marker and the process device is made by a cable (up to 100m) or by radio link [fr

  17. Individual monitoring and its quality assurance using thermoluminescent CaSO[sub 4]:Dy Teflon tape dosemeters in India

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Popli, K.L.; Varadharajan, G.; Kher, R.K.; Venkataraman, G. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1994-01-01

    CaSO[sub 4]:Dy Teflon thermoluminscence dosemeters have been fabricated indigenously in continuous tape form. TL response of the tape dosemeters to [beta] and [gamma] radiations has been studied as a function of the dosemeter thickness to arrive at its optimum value. A single 80 mg.cm[sup -2] thick tape dosemeter (51 mm x 17 mm) along with a mica strip replaces the earlier use of three 200 mg.cm[sup -2] thick disc dosemeters for routine individual monitoring. The tape cards have been in field use for two and half years. The performance characteristics of the cards under laboratory and field conditions are discussed. Dose computation algorithms have been developed to give whole-body dose (mGy) and skin dose (mGy)for photons and [beta] radiation respectively from the TL outputs of three dosimetric elements under 1000 mg.cm[sup -2] Cu + Al composite filter, 180 mg.cm[sup -2] Perspex and an open region in a cardholder. Results of the Quality Assurance Programme, covering various TL monitoring stations in India, are also presented. Based on ANSI criteria, only one outlier was observed over the past seven years. (Author).

  18. Design-Based Research

    DEFF Research Database (Denmark)

    Gynther, Karsten; Christensen, Ove; Petersen, Trine Brun

    2012-01-01

    I denne artikel introduceres Design Based Research for første gang på dansk i et videnskabeligt tidsskrift. Artiklen præsenterer de grundlæggende antagelser, som ligger til grund for Design Based Research-traditionen, og artiklen diskuterer de principper, som ligger til grund for gennemførelse af...... et DBR-forskningsprojekt. Med udgangspunkt i forsknings- og udviklingsprojektet ELYK: E-læring, Yderområder og Klyngedannelse, præsenteres den innovationsmodel, som projektet har udviklet med udgangspunkt i Design Based Research traditionen. ELYKs DBR innovationsmodel har vist sig effektiv i forhold...

  19. Improvement of personal dosimetry - Digital pocket dosemeter

    International Nuclear Information System (INIS)

    Radalj, Z.; Cerovac, Z.; Cerovac, H.; Brumen, V.; Prlic, I.

    1996-01-01

    Physical dosimetric surveillance of professional groups working with various radiation sources is a regular procedure in Croatia, established almost 40 years ago. Data available point out that the majority of professionals under surveillance are those employed in medical facilities, most of them working with X-ray sources. Depending on the nature of professional activities, personnel occupationally exposed to radiation sources are obliged to wear either film badge, TLD or film+TLD badge. Unfortunately, due to the line of data processing, all standard dosemeters have the same disadvantage i.e. up to 40 days delay in dose reporting, regarding the time of actual exposure. The significance of such a delay raises in cases when radiation dose was received within the short time or when technical failure on the operating unit(s) is suspected. Bearing this in mind, the additional dosimetric monitoring becomes an imperative. Therefore, we decided to introduce a palette of digital pocket dosemeters, meant to be used in different workplaces in the radiation zone, each of them being adjusted to the specificities of a particular workplace

  20. Energy dependence of pMOS dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Savic, Z. [Military Technical Institute, Belgrade (Yugoslavia); Stankovic, S.; Kovacevic, M.; Petrovic, M. [Institute of Nuclear Sciences, Belgrade (Yugoslavia). Radiation Protection Dept.

    1996-10-01

    The results are presented of experimental work and numerical simulations of the energy response for pMOS dosimetric transistors in their custom packages. Specially produced radiation soft pMOS transistors were used in this experimental work. The irradiation of pMOS dosemeters was done using {sup 60}Co and {sup 137}Cs sources, a dosimetric X ray unit, and a radiotherapeutic linear accelerator in the range of photon energies from 21 keV to 8 MeV. The results show that package geometry and materials can significantly affect and smooth the energy dependence of pMOS transistors and that in custom transistor packages they are not tissue-equivalent dosemeters. Their response in the photon energy range of 45 to 250 keV is significantly larger than it should be (maximum dose enhancement factor can be as high as 8) and some energy compensation techniques must be used in order to fulfill the requirements of corresponding standards. (Author).

  1. Problem Based Game Design

    DEFF Research Database (Denmark)

    Reng, Lars; Schoenau-Fog, Henrik

    2011-01-01

    At Aalborg University’s department of Medialogy, we are utilizing the Problem Based Learning method to encourage students to solve game design problems by pushing the boundaries and designing innovative games. This paper is concerned with describing this method, how students employ it in various ...... projects and how they learn to analyse, design, and develop for innovation by using it. We will present various cases to exemplify the approach and focus on how the method engages students and aspires for innovation in digital entertainment and games.......At Aalborg University’s department of Medialogy, we are utilizing the Problem Based Learning method to encourage students to solve game design problems by pushing the boundaries and designing innovative games. This paper is concerned with describing this method, how students employ it in various...

  2. Liaison based assembly design

    Energy Technology Data Exchange (ETDEWEB)

    Ames, A.; Kholwadwala, D.; Wilson, R.H.

    1996-12-01

    Liaison Based Assembly Design extends the current information infrastructure to support design in terms of kinematic relationships between parts, or liaisons. These liaisons capture information regarding contact, degrees-of-freedom constraints and containment relationships between parts in an assembly. The project involved defining a useful collection of liaison representations, investigating their properties, and providing for maximum use of the data in downstream applications. We tested our ideas by implementing a prototype system involving extensions to Pro/Engineer and the Archimedes assembly planner. With an expanded product model, the design system is more able to capture design intent. When a product update is attempted, increased knowledge availability improves our ability to understand the effect of design changes. Manufacturing and analysis disciplines benefit from having liaison information available, so less time is wasted arguing over incomplete design specifications and our enterprise can be more completely integrated.

  3. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  4. Environmental radiation measurements using lithium fluoride thermoluminescence dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, C.M.H.; Green, B.M.R.; McKinlay, A.F.; Richards, D.J. (National Radiological Protection Board, Harwell (UK))

    1984-01-01

    The National Radiological Protection Board is involved in a large scale environmental survey of radiation levels in homes throughout the United Kingdom. Passive radon and gamma ray dosemeters are posted to a representative sample of households. Lithium fluoride thermoluminescence dosemeters are used to assess natural gamma radiation and are left in the measurement location for a period of six months before being returned to the Board for processing. As a preliminary to the national survey, the Board has been engaged on several limited surveys in regions of igneous and sedimentary geology. Experience gained in these limited surveys and from standardisation studies using environmental dosemeters are reported.

  5. Design bases - Concrete structures

    International Nuclear Information System (INIS)

    Diaz-Llanos Ros, M.

    1993-01-01

    The most suitable title for Section 2 is 'Design Bases', which covers not only calculation but also the following areas: - Structural design concepts. - Project criteria. - Material specifications. These concepts are developed in more detail in the following sections. The numbering in this document is neither complete nor hierarchical since, for easier cross referencing, it corresponds to the paragraphs of Eurocode 2 Part 1 (hereinafter 'EUR-2') which are commented on. (author)

  6. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter; Determinacion de curvas de isodosis en Radioterapia usando un dosimetro de Alanina/ESR

    Energy Technology Data Exchange (ETDEWEB)

    Chen, F.; Baffa, O.; Graeff, C.F.O. [Departamento de Fisica e Matematica. Universidade de Sao Paulo FFCLRP. 14040-901 Ribeirao Preto-SP (Brazil)

    1998-12-31

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band ({approx} 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  7. Production of thermoluminescent dosemeters based on MgB4O7: Dy and MgB4O7: Tm

    International Nuclear Information System (INIS)

    Souza, Luiza Freire de; Souza, Divanizia N.

    2013-01-01

    The thermoluminescent dosimetry (TL) is a well-established technique for the detection of ionizing radiation in hospitals, clinics, and industrial establishments where there is the need to quantify the radiation. For this practice is require the use phosphors which are sensitive to radiation. Some phosphors are already commonly used in this practice, for example, TLD-100 (LiF: Mg, Ti), CaSO 4 :Tm and CaSO 4 :Dy. A compound that was most recently introduced in dosimetry and has many advantageous features to detect neutrons, electrons and gamma is the magnesium tetraborate (MgB 4 O 7 ), but the undoped material is not good for dosimetry, since signal does not show satisfactory thermoluminescence. The present work presents the analysis of the compound MgB 4 O 7 when doped with rare earth elements, thulium (Tm) and dysprosium (Dy). The production of MgB 4 O 7 : Dy and MgB 4 O 7 : Tm occurred under acidic conditions. Following the process of crystal growth, several tests were made on phosphors produced to verify the quality of materials as TL dosimeter. Initially, was made the identification of the crystalline phases found in the material, using the technique of X-ray diffractometry, and then were evaluated and compared the TL emission curves of the crystals with two different types of dopants, to this, the samples were irradiated with different radiation sources: 137 Cs (0,66 MeV), 60 Co (1.25 MeV) and X-rays (0.41 MeV) and based on the results was evaluated the energy dependence of phosphors. Another characteristic analyzed, was the decay of TL signal for the material (fading). The results show that the material can be an excellent TL dosimeter when doped with rare earth elements Dy and Tm. (author)

  8. Active electronic personal dosemeter in interventional radiology

    International Nuclear Information System (INIS)

    Prlic, I.; Suric Mihic, M.; Vucic, Z.

    2008-01-01

    A recently developed active electronic personal dosemeter (AEPD) was utilised in order to measure the levels and the structure of occupational exposure to scattered X-ray radiation of medical staff who performed percutaneous revascularisation therapy that involves interventional radiology (IR) on the pelvis and upper leg arteries. The AEPDs, placed on the operators' and assistants' chests, that is, above the protective apron, continuously measured and recorded the received doses and, as a novelty, dose rates as a function of time, thus yielding a unique record of occupational doses and dose rates pattern at the working place. This paper presents and discusses one typical daily pattern in which seven percutaneous interventions were performed. (authors)

  9. Calibration of Far West Technology (FWT-60) radiachromic dye dosemeters

    International Nuclear Information System (INIS)

    Mincher, B.J.; Zaidi, M.K.

    1992-01-01

    Radiachromic dye dosimetry was used to measure kilogray doses absorbed by various liquid samples during gamma-ray exposure in a spent nuclear fuel pool. The source of nuclear fuel was the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory (INEL). Calibrations were performed using a 60 Co source and were run on bare dosemeters, as well as on dosemeters which mocked to simulate the samples. These dosemeters were prepared as a dye-impregnated nylon film and are commercially available. When exposed to gamma-ray doses of 0.5 to 200 kGy, a color change occurs which has an optical density proportional to absorbed dose. The difference in the calibration curves demonstrated the importance of irradiation of dosemeters under conditions as close to the actual samples as possible. Since these dosemeters could not be immersed directly in the organic solutions of interest, they were sandwiched between layers of lucite and stainless steel. This simulated the conditions inside an irradiated sample and provides a practical method of measuring absorbed doses. The reproducibility of measurements using the radiachromic dye dosemeters is also shown. 10 refs

  10. Calibration of clinical dosemeters in the IAEA water phantom

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Albuquerque, M.P.P.

    1994-01-01

    The procedures recommended by the IAEA Code of Practice were applied at the Calibration Laboratory of Sao Paulo in order to provide in the future the clinical dosemeters users with absorbed dose to water calibration factors for Cobalt 60 radiation beams. In this work the clinical dosemeters were calibrated free in air and in water, and the results were compared, using conversion factors. The several tested clinical dosemeters of different manufacturers and models belong to the laboratory and to hospitals. For the measurements in water the IAEA cubic water phantom was used. The dosemeters were all calibrated free in air in terms of air kerma, and the calibration factors in terms of absorbed dose to water were obtained through conversion factors. the same dosemeters were also calibrated into the water phantom. Good agreement was found between the two methods, the differences were always less than 0.5%. The data obtained during this work show that when the dosemeters are used only in Cobalt 60 radiation and the users apply in the hospital routine work the IAEA Code of Practice, the calibration can be performed directly in the water phantom. This procedure provides the useful calibration factors in terms of absorbed dose to water

  11. Evaluation of personal dosemeters and comparative measurements performed by PTB in the years 1979 through 1984. Pt. 1

    International Nuclear Information System (INIS)

    Boehm, J.; Buchholz, G.

    1986-01-01

    Comparison measurements of the official individual dosemeters performed in the PTB from 1979 to 1984 are described. Also a number of other, unofficial individual dosemeters participated. The performance of the comparison measurements and the types of the individual dosemeters are described. Tables show the values measured with the film dosemeters, with film and TLD dosemeters, and TLD dosemeters as well as dosimetric probes for whole-body and partial body dose measurement. (DG) [de

  12. Development of radiophotometric dosemeters of high sensitivity using plastic scintillators as light intensifiers

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Hamada, M.M.

    1987-01-01

    The use of rectangular plates of plastic scintillators as film holders in conventional photographic dosemeters is reported. The efficiency of their use as light converters for increase the sensitivity of these dosemeters are studied. (M.A.C.) [pt

  13. A passive radon dosemeter suitable for workplaces

    International Nuclear Information System (INIS)

    Orlando, C.; Orlando, P.; Patrizii, L.; Tommasino, L.; Tonnarini, S.; Trevisi, R.; Viola, P.

    2002-01-01

    The results obtained in different international intercomparisons on passive radon monitors have been analysed with the aim of identifying a suitable radon monitoring device for workplaces. From this analysis, the passive radon device, first developed for personal dosimetry in mines by the National Radiation Protection Board, UK (NRPB), has shown the most suitable set of characteristics. This radon monitor consists of a diffusion chamber, made of conductive plastic with less than 2 cm height, containing a CR-39 film (Columbia Resin 1939), as track detector. Radon detectors in workplaces may be exposed only during the working hours, thus requiring the storage of the detectors in low-radon zones when not exposed. This paper describes how this problem can be solved. Since track detectors are also efficient neutron dosemeters, care should be taken when radon monitors are used in workplaces, where they may be exposed to neutrons, such as on high altitude mountains, in the surroundings of high energy X ray facilities (where neutrons are produced by (gamma, n) reactions) or around high energy particle accelerators. To this end, the response of these passive radon monitors to high energy neutron fields has been investigated. (author)

  14. Characterization of the personal thermoluminescent dosemeter of LiF: Mg, Ti + Ptfe

    International Nuclear Information System (INIS)

    Azorin N, J.; Gutierrez C, A.; Gonzalez M, P.

    1991-01-01

    The objective of this work is to characterize the thermoluminescent dosemeters taken place in the laboratory in form of pellets of LiF: Mg, Ti + Ptfe like personal dosemeters, subjecting them to the operation tests proposed by the international standards and comparing them with the TLD-100, the Tl dosemeter more used at the moment for personal dosimetry

  15. Use of a robotic manipulator in the simulation of the automation of a calibration process of dosemeters; Uso de un manipulador robotico en la simulacion de la automatizacion de un proceso de calibracion de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Benitez R, J S; Najera H, M C [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The development of a system based in a manipulative robot which simulates the operative sequence in a calibration process of dosemeters is presented. In this process it is performed the monitoring of the dosemeter positions and the calibrator by mean of an arm of articulated robot which develops the movement sequences and the taking a decision based on the information coming from the external sensors. (Author)

  16. Application of chemical dosemeters during the irradiation of agricultural products

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, A; Stenger, V; Foeldiak, G [Magyar Tudomanyos Akademia, Budapest. Izotopintezete

    1983-09-01

    The joint recommedation by the FAO, WHO and IAEA in 1981 proposed the unrestricted permission of food irradiation under the dose value of 10 kGy (1 Mrd). The chemical dosemeters presented in the paper cover the dose range of 30 Gy to 1 MGy for use to food irradiation safety measurements. The Fricke dosemeter was used in the 50-400 Gy range at radappertization operations of onion, poppy and potato. The alcoholic chlorobenzene dosemeter with oscillometric analysis was applied successfully at low (0.4-4 kGy) ranges, primarily for irradiation dose monitoring of fruits, vegetables, refrigerated poultry etc. The conductometry could be used for dosimetry in the range of 60 Gy to 1 MGy.

  17. Dosimetric of extremities with Dosemeters thermoluminescent in Cuba

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Vera Alonso, L.

    1998-01-01

    From final of the year 1995 in the CPHR implement the service of monitoring of the extremities using Dosemeter thermoluminescent (TL). The dosemeter consists on a metallic ring with a circular hole where a detector of LiF:Mg,Ti is placed (model JR1152C) of 5x5x0.9 mm 3 , covered by a fine layer of polyethylene. In the work the characteristic dosimetric as of the dosemeter is studied it satisfies the main requirements for their use in the monitoring from the exhibition to radiation photonic of the extremities. The doses are also presented registered during the first two years of operation of the service. The results obtained until the moment point out to you practice them of nuclear medicine, radiotherapy and production of substances radioactive how as of more contribution

  18. Proposal of a dosemeter for skin beta radiation dose assessment

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1987-08-01

    Beta radiation is, undoubtedly, less penetrating than X or gamma radiation. Thus, beta radiation sources external to the human body do not cause a significant irradiation of its deeper tissues. However, in some cases, they may contribute in a very important way to the irradiation of the lens of the eyes and, mainly, of the skin. Specially, the hands and finger tips may receive a high dose. In this work some relevant aspects of the individual monitoring in beta radiation fields are discussed and the importance of monitoring this kind of radiation in some activities where the skin absorbed dose may be a limiting factor is evidenced. The main characteristics of the thermoluminescent (TL) response of ultra-thin CaSO 4 : Dy detectors (UT-CaSO 4 : Dy) in the detection of this kind of radiation are also studied. The irradiation are performed with 90 Sr 90 Y, 204 TI and 147 Pm sources. The reproducibility, linearity, dependence on the absorbed dose rate, optical fading, energy and angular dependences of the detector TL responce are investigated. Transmission factors for different thicknesses of tissue equivalent material are obtained for the TL detectors using the three available beta sources. Based on the results obtained, a dosemeter for skin beta radiation absorbed dose assessment with an energy dependence better than 12% is proposed. (Author) [pt

  19. Intercomparison program of personal dosemeters in the Argentine Republic

    International Nuclear Information System (INIS)

    Gregori, B.N.; Papadopulos, S.B.; Kunst, J.J.

    1998-01-01

    During 1997, under the auspices of the Nuclear Regulatory Authority (ARN), its was held the third exercise of intercomparison of laboratories of personal dosimetry. The dosemeters were irradiated in X-ray beams ISO quality W60, W110, W200 and gamma sources cesium 137 and cobalt 60. The irradiation were performed kerma free in air and in phantom in order to study the capacity to evaluate both conditions. An extent range of doses (low-high) have been given 0.3 mSv- 20mSv in order to determine the operative performance o each laboratory. Over 19 laboratories of Argentina, participated 13 (65%) and finished the intercomparison 12 (60%) of them. The systems of dosimetry detection were based on film and TLD. During this intercomparison as inquiry about several items related with the laboratories have been made. In this work are shown the individual laboratory results of the intercomparison related with the acceptance curve criteria ICRP 60 and 55. (author)

  20. Elaboration And Study Of Transfer Alanine/ESR Dosemeters

    International Nuclear Information System (INIS)

    Torres G, Luz A.

    1996-01-01

    The dosimetry is the dose measure imparted by the energy from the ionizing radiation to the matter. The dosemeters is the means used for the determination of such a dose. Diverse dosimetric classes exist, this classification depends in essence of the energy involved in the irradiation process and of its application necessity. It is as well as in radiological protection movie dosemeter is used, and TLD, in the calibration of units, as those of cobalt, the ionization cameras are used, in the detection of superficial contamination the accountants Geiger Muller and proportional etc. The transfer dosimeter Alanine/ESR is used, object of the present work, is characterized because after reading the registered dose, the information is conserved and it can be transferred and read in any team of ESR. Likewise the following dose that is imparted will be added to the previous one registered, this indicates that the dosemeters is of integral character. In the spectra taken ESR, it is determined that the integral double or area under the curve of the spectrum ESR is proportional to the concentration of free radicals generated by the radiation ionization and in turn this concentration is proportional to the dose received by the pills; in last, these proportionality relationships take to that the area under the curve of the spectrum main ESR is proportional to the radiation dose received by the alanine dosemeters. This dosemeter seeks to be an economic alternative that it will lend the calibration service that today offers the ionization Cameras or the acrylic red industrial dosemeters

  1. Validation of response simulation methodology of Albedo dosemeter

    International Nuclear Information System (INIS)

    Freitas, B.M.; Silva, A.X. da

    2016-01-01

    The Instituto de Radioprotecao e Dosimetria developed and runs a neutron TLD albedo individual monitoring service. To optimize the dose calculation algorithm and to infer new calibration factors, the response of this dosemeter was simulated. In order to validate this employed methodology, it was applied in the simulation of the problem of the QUADOS (Quality Assurance of Computational Tools for Dosimetry) intercomparison, aimed to evaluate dosimetric problems, one being to calculate the response of a generic albedo dosemeter. The obtained results were compared with those of other modeling and the reference one, with good agreements. (author)

  2. Using signal ''KVANT-1'' direct-reading dosemeter for the purposes of personnel monitoring

    International Nuclear Information System (INIS)

    Glinskij, G.A.; Karasev, V.S.; Mukhin, I.E.; Chumak, V.K.

    1977-01-01

    Presented is the description of ''KVANT-1'' dosemeter for monitoring personnel doses of gamma and X radiation. The dosemeter permits to judge on the radiation intensity, to control directly the dose being accumulated, to store the reading of the dose accumulated for a necessary period of time, to obtain sound signal in case of reaching the limit of a pre-set dose. Presented are a general view, block diagram, and the discription of the dosemeter desing and operation. Advantages of the ''KVANT-1'' dosemeter are shown as compared with the conventional personnel monitoring IFK-2,3 and KID-2 dosemeters [ru

  3. The influence of the energy distribution of workplace fields on neutron personal dosemeter reading

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.; Hager, L.G.; Horwood, N.A.

    2002-01-01

    Variations in the energy dependence of response of neutron personal dosemeters cause systematic errors in the readings obtained in workplace fields. The magnitude of these errors has been determined theoretically by folding measured and calculated workplace energy distributions with dosemeter response functions, to determine the response of a given personal dosemeter in that field. These results have been analysed with consideration of the dosemeter response to various calibration spectra, and with reference to different workplaces. The dosemeters in the study are discussed in terms of the workplaces for which they can be suitably calibrated. Deficiencies in the published neutron energy distributions are identified

  4. The evaluation of multi-element personal dosemeters using the linear programming method

    International Nuclear Information System (INIS)

    Kragh, P.; Ambrosi, P.; Boehm, J.; Hilgers, G.

    1996-01-01

    Multi-element dosemeters are frequently used in individual monitoring. Each element can be regarded as an individual dosemeter with its own individual dose measurement value. In general, the individual dose values of one dosemeter vary according to the exposure conditions, i. e. the energy and angle of incidence of the radiation. The (final) dose measurement value of the personal dosemeter is calculated from the individual dose values by means of an evaluation algorithm. The best possible dose value, i.e. that of the smallest systematic (type B) uncertainty if the exposure conditions are changed in the dosemeter's rated range of use, is obtained by the method of linear programming. (author)

  5. Reliability based structural design

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2014-01-01

    According to ISO 2394, structures shall be designed, constructed and maintained in such a way that they are suited for their use during the design working life in an economic way. To fulfil this requirement one needs insight into the risk and reliability under expected and non-expected actions. A

  6. Graphite mixed magnesium borate TL dosemeters for beta ray dosimetry

    DEFF Research Database (Denmark)

    Prokic, M; Christensen, Poul

    1984-01-01

    Sintered MgB4O7:Dy dosemeters with graphite contents from 1 to 10% were investigated for application for personnel dosimetry. Data are given on dose response, dose threshold, reproducibility, beta energy response and fading. Furthermore, results from practical field experiments are presented...

  7. Viability of the Fricke dosemeter doped with methylene blue

    International Nuclear Information System (INIS)

    Souza, V.L.B.; Santos, C.D.A.; Rodrigues, K.R.G.; Cunha, M.S.; Figueiredo, M.D.C.; Melo, R.T.

    2009-01-01

    This work aims to find the possible utilization of the Fricke dosemeter doped with methylene blue (FMB) for the dosimetry of photodynamic therapy. The FMB was irradiated wit X rays and light emitted diodes demonstrating positive answers to the stimulus, being probably to be used for dosimetric objectives

  8. About the measurements systems with pen and thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Cortes I, M.E.; Ramirez G, F.P.

    1998-01-01

    In this work it is presented dosimetric data obtained with pen and thermoluminescent dosemeters, which are used by the Occupational Exposure Personnel (OEP) of the Mexican Petroleum Institute (IMP)(1). It was marked several great characteristics as for example, the differences among units which use one and another dosemeter type. Likewise, it is given to know diverse problems that were had in the IMP at relating the data obtained with these dosemeters (which utilizes OEP) and the ICRP 60 recommendations 1990. One of the most important difficulties is to satisfy the recommended limits by ICRP, particularly those that are referring to the units and their complex calculations. With respect to the unities, the ICRP makes reference at the concepts 'dose equivalent' and 'effective dose' with the sievert unit, that the General Regulations for Radiological Safety associates with 'dose equivalent' and 'effective dose equivalent'. It was illustrated the type of dosimetric statistics which are obtained with the TLD lectures and a OEP pen dosemeter during 1997. (Author)

  9. A review of environmental monitoring using solid state dosemeters, and guidelines for technical procedures

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1983-01-01

    The practical aspects of environmental programmes using thermoluminescence and photoluminescence dosemeter systems are reviewed. The review discusses developments in national and international standards, and discusses the optimisation of the read-out technique, routine calibration procedures and the treatment of random and systematic errors. The paper discusses the problems of measuring man-made dose contributions with low random errors, the estimation of this contribution being based on the interpretation of field results, taking into account the contribution of natural background radiation and of transit exposures. (author)

  10. Design based entrepreneurship

    DEFF Research Database (Denmark)

    Nielsen, Louise Møller; Wikström, Anders; Tollestrup, Christian

    2013-01-01

    Designers are often recognized as natural entrepreneurs, due to their creative skills and competences in the idea-generation and product development processes. A number of studies shows that creative professionals are more likely to become self-employed. In general though, there are not many stud...

  11. A filter technique for optimising the photon energy response of a silicon pin diode dosemeter

    International Nuclear Information System (INIS)

    Olsher, R.H.; Eisen, Y.

    1996-01-01

    Unless they are energy compensated, silicon PIN diodes used in electronic pocket dosemeters, have significant over-response below 200 keV. Siemens is using three diodes in parallel with individual filters to produce excellent energy and angular response. An algorithm based on the photon spectrum of a single diode could be used to flatten the energy response. The commercial practice is to use a single diode with a simple filter to flatten the energy response, despite the mediocre low energy photon. The filter technique with an opening has been used for energy compensating GM detectors and proportional counters and a new variation of it has been investigated which compensates the energy response of a silicon PIN diode and maintains an extended low energy response. It uses a composite filter of two or more materials with several openings whose individual area is in the range of 15% to 25% of the diode's active area. One opening is centred over the diode's active area and others are located at the periphery of the active area to preserve a good polar response to ±45 o . Monte Carlo radiation transport methods were used to simulate the coupled electron-photon transport through a Hamamatsu S2506-01 diode and to determine the energy response of the diode for a variety of filters. In current mode, the resultant dosemeter energy response relative to air dose was within -15% and +30% for 0 o incidence over the energy range from 15 keV to 1 MeV. In pulse mode, the resultant dosemeter energy response was within -25% and +50% for 0 o incidence over the energy range from 30 keV to 10 MeV. For ±45 o incidence, the energy response was within -25% and +40% from 40 keV to 10 MeV. Theoretical viability of the filter technique has been shown in this work (Author)

  12. Activity-based design

    DEFF Research Database (Denmark)

    Andersen, Peter Bøgh

    2006-01-01

      In many types of activities communicative and material activities are so intertwined that the one cannot be understood without taking the other into account. This is true of maritime and hospital work that are used as examples in the paper. The spatial context of the activity is also important:...... and automatic machinery can replace one another in an activity. It also gives an example of how to use the framework for design....

  13. Evaluation of BICRON NE MCP DXT-RAD passive extremity dosemeter

    CERN Document Server

    Yuen, P S; Frketich, G; Rotunda, J

    1999-01-01

    Passive extremity dosemeters currently used in dosimetry communities worldwide have shortcomings. In general, an extremity dosemeter has too thick a detector element, and the dosemeter response is highly energy dependent for beta rays with energies ranging from 200 keV to 2 MeV. It often does not have dosemeter identification, causing problems in the chain of custody. It is often read manually, rendering reading/packing operations very labour intensive. As a result of collaboration between AECL and BICRON NE, a new extremity dosemeter, incorporating a highly sensitive LiF:Mg,Cu,P TLD and tentatively code named MCP DXT-RAD, was developed. It has been evaluated for radiological performance against an ISO draft standard for extremity dosemeters in twelve categories: homogeneity, detection threshold, beta ray energy response, beta angular response, photon energy response, photon angular response, reproducibility, stability under various climatic conditions, linearity, residue, self irradiation, and effect of ligh...

  14. Web Based Customized Design

    OpenAIRE

    Moi, Morten Benestad

    2013-01-01

    This thesis studies the methods needed to create a web based application to remotely customize a CAD model. This includes customizing a CAD model by using a graphical user interface to be able to remotely control the inputs to- and outputs from the model in NX, and to get the result sent back to the user. Using CAD systems such as NX requires intensive training, is often a slow process and gives a lot of room for errors. An intuitive, simple user interface will eliminate the need for CAD trai...

  15. Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber

    International Nuclear Information System (INIS)

    Hakanen, A.T.; Sipilae, P.M.; Kosunen, A.

    2004-01-01

    A scintillation dosemeter is calibrated for 90 Sr/ 90 Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall uncertainty of the present calibration is ca. 6% (2 sd). A calibrated beta-ray ophthalmic applicator can be used as a reference source for further calibrations performed in the laboratory or in the hospital

  16. Characteristic of the dosemeter used by the service of film dosimetry in the CPHR

    International Nuclear Information System (INIS)

    Capote Ferrera, E.A.; Diaz Bernal, E.; Manzano de Armas, J.F.

    1998-01-01

    Characteristic of the dosemeter used by the service of dosimetria filmica of the CPHR.The use of film dosemeter brings I get the aquisition first it gives data that it includes its evaluation regarding the calibration magnitude and second the interpretation of these data in terms of the magnitude of personal dose, such as the equivalent dose (ICRU 47) or to the effective dose (ICRP 60). presently work the results of the study of the characteristics of the dosemeters are picked up

  17. Thermoluminescence sensitivity variations in LiF PTFE dosemeters incurred by improper handling procedures

    CERN Document Server

    Mason, E W; MacKinlay, Alistair F; Saunders, D

    1975-01-01

    A systematic study of some anomalous darkening effects and thermoluminescence sensitivity variations observed in LiF:PTFE thermoluminescent dosemeters is described. Various likely causes of such effects have been investigated. The manufacturer's recommended cleaning procedures have been found to be inadequate and, in some cases, have been found to actually promote discolouration of the dosemeters. Recommendations are given for the successful use of LiF:PTFE thermoluminescent dosemeters in personal dosimetry.

  18. C-program LINOP for the evaluation of film dosemeters by linear optimization. User manual

    International Nuclear Information System (INIS)

    Kragh, P.

    1995-11-01

    Linear programming results in an optimal measuring value for film dosemeters. The Linop program was developed to be used for linear programming. The program permits the evaluation and control of film dosemeters and of all other multi-component dosemeters. This user manual for the Linop program contains the source program, a description of the program and installation and use instructions. The data sets with programs and examples are available upon request. (orig.) [de

  19. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermic neutrons

    International Nuclear Information System (INIS)

    Fratin, L.; Cruz, M.T. da

    1987-01-01

    The production of solid thermoluminescent dosemeters sensible to thermic neutrons is described. The stages of the production are described: vitrification of sodium tetraborate, mixture and cold pressing, syntherization. The obtention of a CaF 2 : natural dosemeter with NaCl which presents sensibility to gamma radiation similar to CaF 2 : natural dosemeter with Na 2 B 4 O 7 is studied. (M.A.C.) [pt

  20. Thermoluminescent dosemeters of CaSO4: Dy + Teflon

    International Nuclear Information System (INIS)

    Campos, L.L.

    1989-01-01

    The development of a pellet dosemeter of CaSO 4 : Dy + Teflon at the Dosimetric Materials Production Laboratory - IPEN/Brazilian CNEN-SP is presented. The pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. The pellet characteristics from the point of view of dosimetry. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these three filters allows to determine the energy of an unknown source. (author) [pt

  1. CaSO4: Dy + Teflon thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Campos, L.L.

    1986-01-01

    A pellet dosemeter of CaSO 4 : Dy + Teflon was developed at IPEN. CaSO 4 : Dy thermoluminescent phosphor, grown in the Dosimetric Materials Production Laboratory was chosen, due to its high sensitivity, ease of preparation and comparatively low cost. Pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. Extensive work was done to study in detail all CaSO 4 : Dy pellets characteristics from the point of view of dosimetry with the purpose of introducing it in the routine use. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these tree filters allows the exposure as well as the energy determination of an unknown source. (Author) [pt

  2. Re-assessment of dose from the Vinten extremity dosemeter

    International Nuclear Information System (INIS)

    O'Hagan, J.B.; Pearson, A.J.; Dutt, J.C.

    1989-01-01

    A procedure is described for re-assessing the dose from the Vinten extremity dosemeter using phototransferred thermoluminescence. The technique produces a linear response up to 50 Sv. The re-assessment efficiency is approximately 10% for the first re-assessment and 3-5% for the second re-assessment. The detection threshold values (at the 95% confidence level) are 3 mSv and 9 mSv respectively. (author)

  3. Application of beta transmission for quality assurance of TLD tape dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Gupta, S.K.; Supe, S.J. (Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection)

    1993-03-01

    Transmission of [sup 204]Tl [beta] radiation enables measurement of differences of [+-] 2 mg/cm[sup 2] in thermoluminescent tape dosemeter thickness. This thickness variation gives rise to a maximum variation of [+-] 5% in the TL output per unit area of the dosemeters. Measurements of [beta] transmission on dosemeter samples drawn from several batches of skived tape as well as those prepared by compressing technique have given consistent results. The [beta] transmission method itself can be used for quality assurance and selection of a uniform set of dosemeters over thickness range 30-150 mg/cm[sup 2]. (author).

  4. Official dosimetry with individual electronic dosemeters - the concept in Germany

    International Nuclear Information System (INIS)

    Czarwinski, R.; Kaulard, J.; Pfeffer, W.

    2005-01-01

    Full text: Presently, in Germany passive dosemeters (film batches, RPL, TLD) are used for the official individual monitoring of occupational exposed personal. The application of electronic individual dosemeters (EPD) is carried out mainly for the operative radiation protection control particularly in nuclear power engineering companies, big hospitals und research centres. This means in such institutions double monitoring exists - legally and operatively. A crucial advantage of EPD compared to passive dosemeter is the possibility to adapt the monitoring period to the working time in the control area, e.g. a job related monitoring is available. Germany started a project for an optimized implementation of EPD into the official dosimetry. Objective of the project whose results will be described in the paper is the harmonization of radiation protection of companies workers and outside workers concerning the record of individual and job related exposures. The approval of the EPD by the Federal and Laender authorities as an official dosimetric system demands the implementation of special requirements concerning the data acquisition, data transfer and data evaluation. These issues are focuses of the Federal research project, supervised by the Federal Office for Radiation Protection (BfS) and performed by the Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS), Cologne to develop a concept in the first stage. (author)

  5. Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments

    International Nuclear Information System (INIS)

    Lee, K.W.; Sheu, R.J.

    2015-01-01

    High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with 252 Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing 252 Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6-8 extended-range sphere versus the 6'' standard sphere). (authors)

  6. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co60

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm -2 of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn t exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with and

  7. Systematic processing of the external individual monitoring data obtained by photographic film and capacitor dosemeters

    International Nuclear Information System (INIS)

    Krueger, F.; Shtuk, D.

    1983-01-01

    Individual radiation load measurements have been carried out both with photographic film and capacitor type dosemeters (CD). Systematic statistics methods were applied for the obtained data processing. The CD data were shown to exceed those measured with the film dosemeters. Specific features of the CD application are revealed that should be taken into account in practice [ru

  8. Development of radiophotometric dosemeters with high sensitivity using plastic scintillators as a light intensifier

    International Nuclear Information System (INIS)

    Mesquita, C.H. de; Hamada, M.M.

    1987-01-01

    Rectangular plates of plastic scintillators are developed and their effect as light converter evaluated, when used as film-holder in conventional photography dosemeters. In this dosemeter, the radiation that not interacts in the photographic film can be detected by light photons generation in the plastic scintillators, sensitizing the film. (C.G.C.) [pt

  9. Verification of Ca F2:Mn type of dosemeters for personal dosimetry purposes

    International Nuclear Information System (INIS)

    Misovic, M.; Boskovic, Z.; Spasic-Jokic, V.

    1995-01-01

    Verification results of CaF2:Mn type of dosemeters for personal dosimetry purposes are presented in this paper. Tree types of irradiations are proceeded due to verification of relevant features of TLD. It is concluded that mentioned type of dosemeter can be used for purpose of personal dosimetry. (author)

  10. Reliability Based Ship Structural Design

    DEFF Research Database (Denmark)

    Dogliani, M.; Østergaard, C.; Parmentier, G.

    1996-01-01

    This paper deals with the development of different methods that allow the reliability-based design of ship structures to be transferred from the area of research to the systematic application in current design. It summarises the achievements of a three-year collaborative research project dealing...... with developments of models of load effects and of structural collapse adopted in reliability formulations which aim at calibrating partial safety factors for ship structural design. New probabilistic models of still-water load effects are developed both for tankers and for containerships. New results are presented...... structure of several tankers and containerships. The results of the reliability analysis were the basis for the definition of a target safety level which was used to asses the partial safety factors suitable for in a new design rules format to be adopted in modern ship structural design. Finally...

  11. Electron scattering effects on absorbed dose measurements with LiF-dosemeters

    International Nuclear Information System (INIS)

    Bertilsson, G.

    1975-10-01

    The investigation deals with absorbed dose measurements with solid wall-less dosemeters. Electron scattering complicates both measurement of absorbed dose and its theoretical interpretation. The introduction of the dosemeter in a medium causes perturbations of the radiation field. This perturbation and its effect on the distribution of the absorbed dose inside the dosemeter is studied. Plane-parallel LiF-teflon dosemeters (0.005 - 0.1 g.cm -2 ) are irradiated by a photon beam ( 137 Cs) in different media. The investigation shows that corrections must be made for perturbations caused by electron scattering phenomena. Correction factors are given for use in accurate absorbed dose determinations with thermoluminescent dosemeters. (Auth.)

  12. Dose equivalent response of personal neutron dosemeters as a function of angle

    International Nuclear Information System (INIS)

    Tanner, J.E.; McDonald, J.C.; Stewart, R.D.; Wernli, C.

    1997-01-01

    The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D 2 O-moderated 252 Cf neutron sources while mounted on a 40 x 40 15 cm 3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher. (author)

  13. Method of making isodose curve using thermoluminescence dosemeter

    International Nuclear Information System (INIS)

    Bakar Ramain, A.

    1975-01-01

    Line source of 60 Co in the form of needles and tubes are extensively used in radiotherapy in moulds, implants, and intracavitary techniques for the treatment of malignant lesions. It is important to have isodose distributions in tissue for those source for purposes of treatment planning. The isodose distributions have been obtained experimentally by using tinny lithium-fluoride (Lsub(i)F) thermoluminescent dosemeters (TLD) and they are compared to the theoretical results. The distinct advantages of Lsub(i)F (TLD) in such measurements are briefly discussed. (author)

  14. Aluminium nitrate ceramics: A potential UV dosemeter material

    DEFF Research Database (Denmark)

    Trinkler, L.; Bøtter-Jensen, L.; Berzina, B.

    2002-01-01

    The ceramic material AIN-Y2O3 is proposed as a potential ultraviolet radiation (UVR) dosemeter using optically stimulated luminescence (OSL) and thermally stimulated luminescence (TL). Experimental studies have shown that AIN ceramics exhibit attractive characteristics suitable for practical UV...... dosimetry applications. The features are: (1) the spectral sensitivity covers the 200-350 nm range, in the UV-B region it is similar to that of human skin: (2) the angular dependence of the incident radiation follows the cosine law; (3) high yields of both UVR-induced OSL and TL signals compared to those...

  15. Results of the IAEA/RCA personal dosemeter intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Momose, Takumaro; Hayashi, Naomi [Environment and Safety Division, Tokai Works, Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2000-06-01

    The intercomparison of personal dosemeters for photon was carried out between 1990 and 1996 as part of the IAEA/RCA 'strengthening of radiation protection infrastructure' project. Japan Nuclear Cycle Development Institute participated in the intercomparison as one of the in-house personal dosimetry service organizations in Japan and also served the host irradiating laboratory. This report summarizes the dose evaluation results obtained from the JNC-TLD badges in the past four intercomparison programs. In the latest intercomparison the evaluated doses agreed to the reference doses with an accuracy of 10%. (author)

  16. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  17. Reusing Design Knowledge Based on Design Cases and Knowledge Map

    Science.gov (United States)

    Yang, Cheng; Liu, Zheng; Wang, Haobai; Shen, Jiaoqi

    2013-01-01

    Design knowledge was reused for innovative design work to support designers with product design knowledge and help designers who lack rich experiences to improve their design capacity and efficiency. First, based on the ontological model of product design knowledge constructed by taxonomy, implicit and explicit knowledge was extracted from some…

  18. Displacement Based Seismic Design Criteria

    International Nuclear Information System (INIS)

    Costello, J.F.; Hofmayer, C.; Park, Y.J.

    1999-01-01

    The USNRC has initiated a project to determine if any of the likely revisions to traditional earthquake engineering practice are relevant to seismic design of the specialized structures, systems and components of nuclear power plants and of such significance to suggest that a change in design practice might be warranted. As part of the initial phase of this study, a literature survey was conducted on the recent changes in seismic design codes/standards, on-going activities of code-writing organizations/communities, and published documents on displacement-based design methods. This paper provides a summary of recent changes in building codes and on-going activities for future codes. It also discusses some technical issues for further consideration

  19. Watershed-based survey designs

    Science.gov (United States)

    Detenbeck, N.E.; Cincotta, D.; Denver, J.M.; Greenlee, S.K.; Olsen, A.R.; Pitchford, A.M.

    2005-01-01

    Watershed-based sampling design and assessment tools help serve the multiple goals for water quality monitoring required under the Clean Water Act, including assessment of regional conditions to meet Section 305(b), identification of impaired water bodies or watersheds to meet Section 303(d), and development of empirical relationships between causes or sources of impairment and biological responses. Creation of GIS databases for hydrography, hydrologically corrected digital elevation models, and hydrologic derivatives such as watershed boundaries and upstream–downstream topology of subcatchments would provide a consistent seamless nationwide framework for these designs. The elements of a watershed-based sample framework can be represented either as a continuous infinite set defined by points along a linear stream network, or as a discrete set of watershed polygons. Watershed-based designs can be developed with existing probabilistic survey methods, including the use of unequal probability weighting, stratification, and two-stage frames for sampling. Case studies for monitoring of Atlantic Coastal Plain streams, West Virginia wadeable streams, and coastal Oregon streams illustrate three different approaches for selecting sites for watershed-based survey designs.

  20. Absorbed dose measurements in mammography using Monte Carlo method and ZrO2+PTFE dosemeters

    International Nuclear Information System (INIS)

    Duran M, H. A.; Hernandez O, M.; Salas L, M. A.; Hernandez D, V. M.; Vega C, H. R.; Pinedo S, A.; Ventura M, J.; Chacon, F.; Rivera M, T.

    2009-10-01

    Mammography test is a central tool for breast cancer diagnostic. In addition, programs are conducted periodically to detect the asymptomatic women in certain age groups; these programs have shown a reduction on breast cancer mortality. Early detection of breast cancer is achieved through a mammography, which contrasts the glandular and adipose tissue with a probable calcification. The parameters used for mammography are based on the thickness and density of the breast, their values depend on the voltage, current, focal spot and anode-filter combination. To achieve an image clear and a minimum dose must be chosen appropriate irradiation conditions. Risk associated with mammography should not be ignored. This study was performed in the General Hospital No. 1 IMSS in Zacatecas. Was used a glucose phantom and measured air Kerma at the entrance of the breast that was calculated using Monte Carlo methods and ZrO 2 +PTFE thermoluminescent dosemeters, this calculation was completed with calculating the absorbed dose. (author)

  1. Evaluation of the kinetic parameters of CaF2:Tm (TLD-300) thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Azorin, Juan; Gutierrez, Alicia; Furetta, Claudio

    1989-01-01

    The kinetic parameters of the first, third and fifth peaks of CaF 2 :Tm (TLD-300) dosemeters were determined experimentally using methods based on initial rise, peak shape, different heating rates, isothermal decay and numerical fitting method and a comparison was made between the results obtained. The average activation energy values determined by the methods used here were 0.72, 1.16 and 1.77 eV, with mean values for the frequency factor of 2.58 x 10 8 , 2.89 x 10 13 and 6.16 x 10 16 s -1 for the first, third and fifth peaks respectively. The values of activation energy obtained for each peak using the different methods covered a spread of about 4%. However, the spread for each of the frequency factors was very high. (author)

  2. Type testing of the Siemens Plessey electronic personal dosemeter.

    Science.gov (United States)

    Hirning, C R; Yuen, P S

    1995-07-01

    This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.

  3. Understanding differences in dose-equivalents reported by passive and electronic personal dosemeters

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Burgess, Peter; Smith, David; Salasky, Mark; Yahnke, Cliff

    2008-01-01

    Full text: In a number of challenging environments, clients occasionally double badge with electronic personal dosemeters (EPDs) to ensure day-to-day management of their employees personal dose-equivalent while using passive (in our case Luxel or InLight) dosemeters for monthly monitoring for approved results for dose record keeping. In some cases there have been significant differences in the cumulative doses recorded by the EPDs and the passive dosemeters. In these circumstances the passive dosemeters usually report a higher dose than the EPD by up to a factor of two, though more commonly 1.3. In this paper we describe the differences seen between EPD and passive dosemeters (in a number of countries). We then examine the possible causes for such discrepancies by comparison with published response function data available for the EPDs and Landauer dosemeters. We have undertaken a number of experiments comparing directly a number of EPDs and passive dosemeter response to a variety of energy and complex angular geometries where the two types of dosimeter have been exposed at the same time. Recommendations will be made on the appropriate use of double badging in difficult environments and interpretation of the results. (author)

  4. Individual TL detector characteristics in automated processing of personnel dosemeters: correction factors as extension to identity codes of dosemeter cards

    International Nuclear Information System (INIS)

    Toivonen, Matti.

    1979-07-01

    One, two and three-component dosemeter cards and their associated processing equipment were developed for personnel monitoring. A novel feature of the TLD system is that the individual sensitivity correction factors of TL detectors for β/γ radiation dosimetry and special timing factors for the readout of neutron detectors are stored on dosemeter cards as an extension of the identity codes. These data are utilized in the automatic TL reading process with the aim of cancelling out the influence of the individual detector characteristics on the measuring results. Stimulation of TL is done with hot nitrogen without removing the detectors from their cards and without any metal contact. Changes in detector characteristics are thus improbable. The reading process can be adjusted in a variety of ways. For example, each detector in the same card can be processed with optimal heating and the specific 250 deg C glow peak of neutron radiation can be roughly separated from the main LiF glow peaks. (author)

  5. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  6. The use of active personal dosemeters as a personal monitoring device: Comparison with TL dosimetry

    International Nuclear Information System (INIS)

    Boziari, A.; Koukorava, C.; Carinou, E.; Hourdakis, C. J.; Kamenopoulou, V.

    2011-01-01

    The use of active personal dosemeters (APDs) not only as a warning device but also, in some cases, as an official and hence stand-alone dosemeter is rapidly increasing. A comparison in terms of dose, energy and angle dependence, among different types of APD and a routinely used whole-body thermoluminescence dosemeter (TLD) has been performed. Significant differences were found between the TLD readings and mainly some not commonly used APDs. The importance of choosing the best adapted APD according to the radiation field characteristics is pointed out. (authors)

  7. Risk based seismic design criteria

    International Nuclear Information System (INIS)

    Kennedy, R.P.

    1999-01-01

    In order to develop a risk based seismic design criteria the following four issues must be addressed: (1) What target annual probability of seismic induced unacceptable performance is acceptable? (2) What minimum seismic margin is acceptable? (3) Given the decisions made under Issues 1 and 2, at what annual frequency of exceedance should the safe-shutdown-earthquake (SSE) ground motion be defined? (4) What seismic design criteria should be established to reasonably achieve the seismic margin defined under Issue 2? The first issue is purely a policy decision and is not addressed in this paper. Each of the other three issues are addressed. Issues 2 and 3 are integrally tied together so that a very large number of possible combinations of responses to these two issues can be used to achieve the target goal defined under Issue 1. Section 2 lays out a combined approach to these two issues and presents three potentially attractive combined resolutions of these two issues which reasonably achieves the target goal. The remainder of the paper discusses an approach which can be used to develop seismic design criteria aimed at achieving the desired seismic margin defined in resolution of Issue 2. Suggestions for revising existing seismic design criteria to more consistently achieve the desired seismic margin are presented. (orig.)

  8. Fragment-based drug design.

    Science.gov (United States)

    Feyfant, Eric; Cross, Jason B; Paris, Kevin; Tsao, Désirée H H

    2011-01-01

    Fragment-based drug design (FBDD), which is comprised of both fragment screening and the use of fragment hits to design leads, began more than 15 years ago and has been steadily gaining in popularity and utility. Its origin lies on the fact that the coverage of chemical space and the binding efficiency of hits are directly related to the size of the compounds screened. Nevertheless, FBDD still faces challenges, among them developing fragment screening libraries that ensure optimal coverage of chemical space, physical properties and chemical tractability. Fragment screening also requires sensitive assays, often biophysical in nature, to detect weak binders. In this chapter we will introduce the technologies used to address these challenges and outline the experimental advantages that make FBDD one of the most popular new hit-to-lead process.

  9. Review of research in feature based design

    NARCIS (Netherlands)

    Salomons, O.W.; van Houten, Frederikus J.A.M.; Kals, H.J.J.

    1993-01-01

    Research in feature-based design is reviewed. Feature-based design is regarded as a key factor towards CAD/CAPP integration from a process planning point of view. From a design point of view, feature-based design offers possibilities for supporting the design process better than current CAD systems

  10. Determination with a condenser type dosemeter of half value lager of X ray beams generated in the range from 50 to 70 kilovolt

    International Nuclear Information System (INIS)

    Morales Monzon, J.A.

    1994-01-01

    The methodology of half value lager measurement based on ratio of unit output measured before and after an additional 4 mm thick aluminium filter has been installed is studied. The use of a condenser type dosemeter model FJ301G3 produced by Beijing Nuclear Instrument Factory for that purpose is studied too. The study is base on measurement of attenuation curves using high purity aluminium filter done with a dosemeter FJ301G3 and a standard ionization chamber model NE 2530/1 from Nuclear Enterprise respectively. The X ray quality generated had similar characteristic 50 high kerma dose rate series normalized by ISO. Expressions that allow estimate half value lager in aluminium with a maximum deviation of 0,25 mm is reported. The easy handling and low cost of dispositives employed are the main advantages of that methodology. According to voltage range in which study was done, the results have application in quality control of dental X ray units

  11. Thermoluminescent dosemeter in a X-ray diffractometer

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T.; Castano, V.M.

    1999-01-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  12. Use of active dosemeters as a optimization tool in hemodynamics

    International Nuclear Information System (INIS)

    Nunes, Rafael; Pereira, Dirceu D.; Rodrigues, Barbara B.D.; Ferreira, Esmeralci

    2016-01-01

    Interventional cardiology procedures are, in general, associated with high doses in patients and professionals. The objective of this study is to measure the radiation levels received by professionals .The professional dosimetry was performed in a department of Hemodynamics of University Hospital in Rio de Janeiro. were followed 331 coronary angiography (CA) and 26 percutaneous transluminal coronary angioplasty (PTCA) procedures. For this, were used active dosemeters to measure the radiation levels at the chest of interventional professionals. The results show that average personal equivalent dose of doctors, per procedure was 100 e 154 μSv. On average, nursing technicians and radiologist receive 12 and 10% of doses of physicians, respectively, during CA procedures. From the results, it appears that the doses of hemodynamics exceed the annual dose limit of the standards. The use of lead shielding is presented as an effective action to reduce doses in these workers. (author)

  13. The role of phantom parameters on the response of the AEOI Neutriran Albedo Neutron Personnel Dosemeter

    International Nuclear Information System (INIS)

    Sohrabi, M.; Katouzi, M.

    1992-01-01

    The response of the AEOI Neutriran Albedo Neutron Personnel Dosemeter (NANPD) which can also be used for other albedo dosemeter types was determined on 18 different phantom configurations. The effects of type, geometry, material, thickness, dosemeter-to-phantom angle in particular with the presence of legs were investigated using a Pu-Be neutron source. It was concluded that the slab phantoms (single or double) and circular and elliptical cylinder phantoms seemed to provide a better response, whereas the ICRU sphere geometry does not seem to be appropriate for the calibration of albedo dosemeters. It is interesting to note that the presence of legs maintains the constancy of the response in a situation when a radiation worker bends down during work. (author)

  14. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2005-01-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ( 137 Cs) and 1252 keV ( 60 Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of 60 Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  15. Personal neutron dosemeter of the Czech Republic: Review of basic properties, results of recent tests

    Czech Academy of Sciences Publication Activity Database

    Trousil, J.; Spurný, František; Plichta, J.

    2006-01-01

    Roč. 14, 7/8 (2006), s. 246-253 ISSN 1210-7085 Institutional research plan: CEZ:AV0Z10480505 Keywords : detectors * dosemeters * personal dosimetry Subject RIV: DN - Health Impact of the Environment Quality

  16. Conversion factors for the ICRU dose equivalent quantities for calibrating radiation dosemeters

    International Nuclear Information System (INIS)

    Grosswendt, B.; Hohlfeld, K.; Kramer, H.M.; Selbach, H.J.

    1985-02-01

    Report describing the application of conversion factors for monoenergetic photon radiation and for X and gamma reference radiation used for dosemeter calibration with the aid of spherical or rectangular phantoms (environmental and individual monitoring). (DG) [de

  17. Solid thermoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermal neutrons

    International Nuclear Information System (INIS)

    Fratin, L.; Cruz, M.T. da

    1987-01-01

    A solid termoluminescent dosemeter of sodium tetraborate and brazilian fluorite sensible to thermal neutrons is described. The nuclears reactions 1) 10 B + n → 7 Li + He + Q1 (6,1%) where: Q1=2,79 MeV and Eα1 = 1,758 MeV and 2) 10 B + n → 7 Li* + 4 He + Q2 (93,9%) where: Q2 = 2,316 MeV and E2α 2 = 1,474 MeV are responsible by the thermoluminescent response of the thermal neutrons dosemeters. The stages in the fabrication process of this dosemeter of which are:1) sodium tetraborate vitrification, 2) mixture and pressing 3) sintering are cited. The obtainment of a natural fluorite dosemeter with sodium chloride is also shown. (C.G.C.) [pt

  18. Basic requirements of dosemeter systems for individual monitoring of external radiation

    International Nuclear Information System (INIS)

    Boehm, J.; Ambrosi, P.

    1985-01-01

    A plea is made for detailed detector independent requirements for dosemeter systems for individual monitoring of external radiation. These requirements should have their origin in the fundamental aspects and concepts of radiation protection for workers, and should be something like a translation of the general principles of individual monitoring into a language easily understandable by producers and users. This work comprises a summary of the general objectives of individual monitoring and discussion of some relevant requirements for dosemeter systems. (orig.) [de

  19. Measurement of gamma radiation doses at the RA reactor by thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Prokic, M.

    1974-01-01

    This paper presents the procedures and gamma radiation doses measured at the exit from the horizontal experimental channel HK-5, vertical experimental channel VK-5 and in the thermal column of the RA reactor in Vinca. Measurement of gamma radiation dose in the mixed intense gamma and neutron radiation field was done by two types of thermoluminescent dosemeters, LiF (TLD-700) and CaF 2 (TLD-08). Gamma dose in the VK-5 was measured in the air and on the bottle filled with tissue-equivalent solution. Increase of the dose on the surface of the bottle was 2.3 compared to the gamma dose value in the air. Correction for the influence of neutrons having different energies was done by using the known sensitivity values of both TL dosemeter types for thermal, intermediate and fast neutrons. Results showed that the TLD-700 dosemeter contains 5 time more Li-6 isotopes (0.035%) than the declared value causing increased neutron sensitivity of this dosemeter. This paper includes numerical sensitivity data for neutrons of different energies for both types of TL dosemeters. Neutron sensitivity values for TLD-700 are related to LiF with 0.035% of Li-6 isotope. Result of measurement have also shown that the CaF 2 :Mn (TLD-08) thermoluminescent dosemeter is more suitable for gamma radiation dose measurements in mixed n-gamma fields with intensive neutron fluxes due to lower neutron sensitivity compared to TLD-700 [sr

  20. Comparison of responses of thermoluminescent dosemeters irradiated by soft x-rays at very low and very high dose rate levels

    International Nuclear Information System (INIS)

    Pietrikova-Farnikova, M.; Krasa, J.; Juha, L.

    1994-01-01

    Recent great progress in construction and application of bright sources of soft X-rays gave a strong impetus for the development of methods of their dosimetric diagnostics. The soft X-ray sources are primarily represented by synchrotron radiation sources and by sources based on laser-produced plasma, including X-ray lasers. Their characteristics spread over a very wide region of photon energies, peak and average powers and densities. From our preliminary experiments it follows that thermoluminescent dosemeters can serve as a suitable tool for the determination of these characteristics. Problem lies in the fact that routine use of the thermoluminescent dosemeters for the dosimetry of soft X-rays requires their spectral calibration, which can be carried out with low peak power sources (synchrotron radiation and radionuclide sources). On the contrary, many important sources, especially these based on laser-produced plasmas, exhibit a very high peak power, i.e. dosemeters are irradiated at extremely high dose rate. In comparative experiments carried out with laser-produced plasmas and radionuclides using TLD 200 (CaF 2 :Dy) and GR 200A (LiF:Mg,Cu,P) it was satisfactorily proven that total thermoluminescent signals are independent of the dose rate. Dependence of glow curve shapes on the dose, dose rate and photon energy were equally determined

  1. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  2. How do hospital sterilisation procedures affect the response of personal extremity rings and of eye lens TL dosemeters?

    International Nuclear Information System (INIS)

    Kopec, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-01-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D TM eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. (authors)

  3. HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?

    Science.gov (United States)

    Kopeć, Renata; Bubak, Anna; Budzanowski, Maciej; Sas-Bieniarz, Anna; Szumska, Agnieszka

    2016-09-01

    Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used. The effects of medical sterilisation procedures were studied: by chemicals, by steam or by ultraviolet (UV), on the dose assessment by extremity rings and by eye lens dosemeters. Since it often happens that a dosemeter is accidentally machine-washed together with protective clothing, the effect of laundering on dose assessment by these dosemeters was also tested. The sterilisation by chemicals is mostly safe for TL detectors assuming that the dosemeters are waterproofed. Following sterilisation by water vapour, the response of these dosemeters diminished by some 30 %, irrespectively of the period of sterilisation; therefore, this method is not recommended. UV sterilisation can be applied to EYE-D™ eye lens dosemeters if their encapsulation is in black. The accidental dosemeter laundry in a washing machine has no impact on measured dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Summary of personal neutron dosemeter results obtained within the EVIDOS project

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Reginatto, M.; Schuhmacher, H.; Bolognese-Milsztajn, T.; Lacoste, V.; Boschung, M.; Fiechtner, A.; Coeck, M.; Vanhavere, F.; Curzio, G.; Errico d', F.; Kylloenen, J.-E.; Lindborg, L.; Bartlett, D.; Tanner, R.

    2005-01-01

    Full text: Within the EC project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'), different types of neutron personal dosemeters were irradiated in workplace fields in nuclear installations in Europe. Mostly electronic personal neutron dosemeters were tested, among them commercial devices (Thermo Electron EPD-N, Aloka PDM-313), devices from first industrial prototype series (Thermo Electron EPD-N2, Saphydose-n) and laboratory prototypes which were already in the stage of lightweight battery-operated instruments (PTB DOS-2002). In addition, dosemeters with (almost) immediate readout (BTI bubble detectors, Rados DIS-N) and passive dosemeters which needed no fielddependent calibration factors (PADC track detectors from PSI and NRPB) were used, as well as those TLD albedo dosemeters which are routinely used in the facilities visited. The results of measurements obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e. at Kruemmel (boiling water reactor, transport cask), at Mol (Venus research reactor, fuel facility Belgonucleaire) and at Ringhals (pressurized water reactor, transport cask) are presented and compared to reference values of personal dose equivalent H p (10) determined by means of Bonner spheres and novel directional spectrometers. In fields with strong back-scatter and moderation of neutrons, several dosemeters showed overreadings by more than a factor of two. In strongly directed fields with neutron dose equivalent peaked at about 1 MeV (MOX fuel), the same dosemeters showed under-readings of about a factor of two. These under- and over-readings in the workplace fields can be explained in terms of the dosemeter response functions for mono-energetic neutrons, which show over-responses in the thermal and intermediate neutron energy region and under-responses at about 1 MeV neutron energy. The dosemeter readings obtained in the workplace fields were checked for consistency by

  5. Team Based Engineering Design Thinking

    Science.gov (United States)

    Mentzer, Nathan

    2014-01-01

    The objective of this research was to explore design thinking among teams of high school students. This objective was encompassed in the research question driving the inquiry: How do teams of high school students allocate time across stages of design? Design thinking on the professional level typically occurs in a team environment. Many…

  6. Uncertainty assessment and comparison of different dose algorithms used to evaluate a two element LiF:Mg,Ti TL personal dosemeter

    International Nuclear Information System (INIS)

    Stadtmann, H.; Hranitzky, F.C.

    2008-01-01

    This paper presents the results of an uncertainty assessment and comparison study of different dose algorithms used for evaluating our routine two element TL whole body dosemeter. Due to the photon energy response of the two different filtered LiF:Mg,Ti detector elements the application of dose algorithms is necessary to assess the relevant photon doses over the rated energy range with an acceptable energy response. Three dose algorithms are designed to calculate the dose for the different dose equivalent quantities, i.e. personal dose equivalent H p (10) and H p (0.07) and photon dose equivalent H x used for personal monitoring before introducing personal dose equivalent. Based on experimental results both for free in air calibration as well as calibration on the ISO water slab phantom (type test data) a detailed uncertainty analysis war performed by means of Monte Carlo simulation techniques. The uncertainty contribution of the individual detector element signals was taken into special consideration. (author)

  7. Decision-Based Design Integrating Consumer Preferences into Engineering Design

    CERN Document Server

    Chen, Wei; Wassenaar, Henk Jan

    2013-01-01

    Building upon the fundamental principles of decision theory, Decision-Based Design: Integrating Consumer Preferences into Engineering Design presents an analytical approach to enterprise-driven Decision-Based Design (DBD) as a rigorous framework for decision making in engineering design.  Once the related fundamentals of decision theory, economic analysis, and econometrics modelling are established, the remaining chapters describe the entire process, the associated analytical techniques, and the design case studies for integrating consumer preference modeling into the enterprise-driven DBD framework. Methods for identifying key attributes, optimal design of human appraisal experiments, data collection, data analysis, and demand model estimation are presented and illustrated using engineering design case studies. The scope of the chapters also provides: •A rigorous framework of integrating the interests from both producer and consumers in engineering design, •Analytical techniques of consumer choice model...

  8. Intercomparison of active personal dosemeters in interventional radiology

    International Nuclear Information System (INIS)

    Clairand, I.; Struelens, L.; Bordy, J. M.; Daures, J.; Debroas, J.; Denozieres, M.; Donadille, L.; Gouriou, J.; Itie, C.; Vaz, P.; D'Errico, F.

    2008-01-01

    The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its sixth Framework Programme. Interventional radiology procedures can be very complex and they can lead to relatively high doses to personnel who stand close to the primary radiation field and are mostly exposed to radiation scattered by the patient. For the adequate dosimetry of the scattered photons, APDs must be able to respond to low-energy [10-100 keV] and pulsed radiation with relatively high instantaneous dose rates. An intercomparison of five APD models deemed suitable for application in interventional radiology was organised in March 2007. The intercomparison used pulsed and continuous radiation beams, at CEA-LIST (Saclay (France)) and IRSN (Fontenay-aux-Roses (France)), respectively. A specific configuration, close to the clinical practice, was considered. The reference dose, in terms of Hp(10), was derived from air kerma measurements and from the measured and calculated energy distributions of the scattered radiation field. Additional Monte Carlo calculations were performed to investigate the energy spectra for different experimental conditions of the intercomparison. The results of this intercomparison are presented in this work and indicate which APDs are able to provide a correct response when used in the specific low-energy spectra and dose rates of pulsed X-rays encountered in interventional radiology. (authors)

  9. Calibration of extremity dosemeters for gamma radiation fields

    International Nuclear Information System (INIS)

    Papadopulos, S.B.; Gregori, B.N.; Cruzate, J.A.

    1998-01-01

    In this work the kerma conversion factor are free in air, dose equivalent H(d,0 ) are presented, they were obtained theoretical and experimentally in finger and arm for gamma radiation fields. Extremity dosemeters put on surface finger and arm phantom have been irradiated. The finger phantom is a solid cylinder of PMMA polymethylmethacrylate 19 mm diameter and 300 mm height. The arm phantom is a 73 mm external diameter cylinder with PMMA walls 2.5 mm thick fill with water and 300 mm height. The radiation sources were cobalt 60 and cesium 137 from the Regional Center of Reference (CRR) of the National Commission of Atomic Energy (CNEA) and the Nuclear Regulatory Authority (ARN). Also in ISO wide X ray spectra W60, W110 and W200 have been irradiated. The results obtained show a good correlation with those published, they have a difference less than 7%. The factors will be applied to the evaluation of the equivalent doses coming from workers whose main irradiated zone is in the hands. (author)

  10. Measurement of doses to aviator pilots using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin N, J.; Cruz C, D.; Rivera M, T.

    2004-01-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  11. Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'

    International Nuclear Information System (INIS)

    Lahaye, T.; Chau, Q.; Menard, S.; Ndontcheung-Moyo, M.; Bolognese-Milsztajn, T.; Rannou, A.

    2004-01-01

    Since 1993, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricite de France (EDF), a R and D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics. (authors)

  12. Energy and angular dependence of the personal dosemeter in use at ITN-DPRSN

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Joao G. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, EN 10, 2686-953 Sacavem (Portugal)], E-mail: jgalves@itn.pt; Calado, Ana M.; Cardoso, Joao V.; Santos, Luis M. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, EN 10, 2686-953 Sacavem (Portugal)

    2008-02-15

    In this paper the characterization of the dosimetry system and of the personal dosemeter in terms of the stability of the reader calibration factors and of the linearity of the response for the 137Cs reference radiation is presented. The energy and angular dependence of the whole body dosemeter are also shown. The energy dependence was determined performing irradiations with the X-ray narrow series beams N30, N40, N60, N80, N100, N120 and with the gamma reference radiations of 137Cs and 60Co [ISO 4037-1, 1996. X and Gamma Reference Radiation for Calibrating Dosemeters and Doserate Meters and for Determining Their Response as a Function of Photon Energy-Part 1: Radiation Characteristics and Production Methods. International Organization for Standardization, Geneva] in terms of Hp(10) incident on the ISO water slab phantom. The angular dependence of the dosemeter was determined for the angles 0 deg., {+-}20 deg., {+-}40 deg. and {+-}60 deg. with normal using the above mentioned radiation fields. All irradiations were performed at the Laboratorio de Metrologia das Radiacoes lonizantes of ITN-DPRSN. The experiments presented in this paper show the thermoluminescence dosimetry (TLD) system is stable and presents a linear behaviour over and extended dose range. The measurements allowed the determination of the energy dependence at normal incidence and of the angular dependence of the dosemeter currently in use. Further studies are being carried out in order to implement correction factors for supralinearity and low energy measurements.

  13. Reflections on Design-Based Research

    DEFF Research Database (Denmark)

    Ørngreen, Rikke

    2015-01-01

    Design-Based Research is an intervention method that researches educational design (products or processes) in real-life settings with the dual purpose of generating theories about the domain and develop the design iteratively. This paper is an integrative review with a personal ethnographic...... narrative that draws on Design-Based Research literature, and identifies and discusses elements from Interaction Design and Action Research that the Design-Based Research approach could apply, situating the research in online educational projects, where participants are distributed in time and space...

  14. The fast neutron response of 7LiF thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1990-02-01

    A series of experiments was performed in 1982 to determine the neutron energy response of the 7 LiF thermoluminescent dosemeter (TLD) employed in European zero power fast reactor gamma-ray energy deposition studies. Preliminary results of this work were included in a 1985 International experimental data-base of TLD neutron sensitivities and provided the most consistent set of data within the 7 LiF compilation. A more detailed interpretation of these data has improved the results still further, giving a mean relative neutron to gamma efficiency of 0.118±0.005. The main objective of this re-evaluation was to establish recommended neutron energy response values to replace a 1974 data set for the analysis of in-core fast reactor measurements. This was achieved by combining the mean experimental relative efficiency of 0.118 with calculated energy dependent kerma factors. The kerma factors for the TLD were based on US National Bureau of Standards values and a composition determined by chemical analysis. Adoption of the revised neutron energy response data set produces a small increase in the measured gamma-ray energy deposition of typically 2% relative to the 1974 data. However, more importantly, the detailed analysis of the experimental response data has significantly improved confidence in the neutron corrections applied to in-core TLD gamma-ray energy deposition measurements. (author)

  15. Mixture design procedure for flexible base.

    Science.gov (United States)

    2013-04-01

    This document provides information on mixture design requirements for a flexible base course. Sections : design requirements, job mix formula, contractor's responsibility, and engineer's responsibility. Tables : material requirements; requirements fo...

  16. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites.

    Science.gov (United States)

    McNeil, Sarah M; Lai, Priscilla; Connolly, Bairbre L; Gordon, Christopher L

    2013-12-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10- to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam.

  17. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites

    International Nuclear Information System (INIS)

    McNeil, S. M.; Lai, P.; Connolly, B. L.; Gordon, C. L.

    2013-01-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10-to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam. (authors)

  18. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  19. Calibration of personal dosemeters in terms of the ICRU operational quantities

    International Nuclear Information System (INIS)

    McDonald, J.C.; Hertel, N.E.

    1992-05-01

    The International Commission on Radiological Units and Measurements (ICRU) has defined several new operational quantities for radiation protection purposes. The quantities to be used for personal monitoring are defined at depths in the human body. Because these quantities are impossible to measure directly, the ICRU has recommended that personal dosemeters should be calibrated under simplified conditions on an appropriate phantom, such as the ICRU sphere. The US personal dosimetry accreditation programs make use of a 30 x 30 x 15 cm polymethymethacrylate (PMMA) phantom, therefore it is necessary to relate the response of dosemeters calibrated on this phantom to the ICRU operational quantities. Calculations of the conversion factors to compute dosemeter response in terms of the operational quantities have been performed using the code MCNP. These calculations have also been compared to experimental measurements using thermoluminescent (TLD) detectors

  20. Design and development of wide energy neutron REM equivalent spectrometer-dosimeters based on polycarbonates and Cr-39

    International Nuclear Information System (INIS)

    Faermann, S.

    1985-03-01

    This work describes a system composed of a Rem response personnel neutron dosemeter, based on boron radiators and a polycarbonate track detector, for monitoring dose equivalents in the energy range 1 eV to 14 MeV, an electrochemical etching system for revealing damage sites in solid state track etch detectors, a reader for magnifying the etched pits and a microprocessor for evaluating the dose equivalents and their uncertainties. The performance and directional dependence of the dosemeter when exposed to monoenergetic and polyenergetic neutron fields in the epithermal and fast energy regions are discussed. Saturation effects in polycarbonate foils are presented and a comparison is made between the response of polycarbonate and CR-39 foils, used as passive detectors in the dosemeter. A new passive miniature fast neutron spectrometer-dosimeter is also described. The device is based on the detection of proton tracks by electrochemical etching of CR-39 foils covered with thin polyethylene layers of different thicknesses. By means of this device it is possible to assess the fast neutron energy spectrum in 10 energy intervals in the energy range 0.5-15 MeV. Dose equivalents can be determined in the dose equivalent range 20 mRem to 8 Rem, approximately (author)

  1. Determination of the dose rapidity of a 90 Sr beta radiation source using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Rivera M, T.

    2000-01-01

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a 90 Sr- 90 Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  2. Use of bubbles dosemeters to measure the neutrons leakage radiations around a medical accelerator

    International Nuclear Information System (INIS)

    Bourgois, L.

    1999-01-01

    In this study, the neutron component has been determined on a medical accelerator (Saturne 43F type accelerator) with the help of bubbles detectors marketed by the Bubble Technology Industry society. BD-PND type dosemeters with sensitivities from 0.1 to 0.23 bubbles/micro sievert have been used. These dosemeters have important advantages: they are small enough and then, homogeneously irradiated, they are insensitive to intense electromagnetic fields and to photons and electrons, they can used several times by compression, the reading of the device does not need expensive means and it is possible to multiply the measure points. (N.C.)

  3. Evidence-based playground design

    DEFF Research Database (Denmark)

    Refshauge, Anne Dahl; Stigsdotter, Ulrika K.; Lamm, Bettina

    2015-01-01

    , best practice, and the theories of Affordances and Behaviour Settings. A post-occupancy evaluation was carried out through a questionnaire survey and observation studies, which revealed that a majority of the potential evidence-based affordances were actualised, and that the application of the theories...

  4. NOMEX - a universal diagnostic dosemeter, mA.s, and kV meter for acceotance test measurements and quality assurance

    International Nuclear Information System (INIS)

    Hein, G.; Pychlau, P.; Schuele, E.

    1992-01-01

    A universal diagnostic dosemeter is introduced which was designed for acceptance test measurements and quality assurance. It can also be used for periodic constancy checks. To facilitate the comprehensive tests, the NOMEX can measure all important quantities, such as dose and dose rate, mean peak voltage, exposure time, mA.s product, dose per mA.s, dose per pulse, attenuation factor, relative standard deviation and length dose product in CT. All these quantities, except the mA.s product, are measured non-invasively. The instrument's concept, its applications and technical data are described. (author)

  5. Challenges to Designing Game-Based Business

    DEFF Research Database (Denmark)

    Henriksen, Thomas Duus

    2014-01-01

    The four categories labelled game-design, didactic design, organisational design and business design each constitute a set of challenges, each requiring a particular set of competencies. The key conclusion of the paper is that even though the learning game design constitutes the core of establish......The four categories labelled game-design, didactic design, organisational design and business design each constitute a set of challenges, each requiring a particular set of competencies. The key conclusion of the paper is that even though the learning game design constitutes the core...... of establishing game based business (GBB), the subsequent stages of development call for other kinds of competencies in order to become a viable GBB....

  6. ERGONOMIC DESIGN RECOMMENDATIONS BASED ON AN ACTUAL CHAINSAW DESIGN

    Directory of Open Access Journals (Sweden)

    J. Kaljun

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: To develop high quality products, a designer has to consider various influential factors, one of which is ergonomics. And to fashion a specific product for the user, a designer needs expert knowledge of the user’s requirements. However, expert knowledge can also be accessed through an intelligent advisory system for ergonomic design support. The effectiveness of such an expert system depends mainly on the quality of the knowledge base and on the appropriateness of the system's inference engine. Data for the system’s knowledge base can be collected in different ways. One approach is to study relevant projects to collect appropriate ergonomic solutions; another is to recognise bottlenecks in ergonomic design. This paper presents a case study of the design of an actual chainsaw – with emphasis on ergonomic design solutions – that can be transformed into ergonomic design recommendations. At the end of the paper, an application of one of the derived recommendations within the knowledge base of the intelligent advisory system is presented.

    AFRIKAANSE OPSOMMING: By die ontwerp van gehaltegoedere moet aandag gegee word aan verskeie faktore soos die Ergonomie. Die produkontwerper moet deeglike kennis dra van die verbruikersbehoeftes. Daarbenewens moet hy liefs ook gebruik maak van ’n intelligente sisteem vir ontwerphulp. Die navorsing is toegespits op datasteun vir ’n kettingsaagontwerp en toon hoe die intelligente sisteem betekenisvolle ondersteuning verleen.

  7. Case-based Agile Fixture Design

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In order to realize the agility of the fixture design, such asreconfigurability, rescalability and reusability, fixture structure is function unit-based decomposed from a fire-new point of view. Which makes it easy for agile fixture to be reconfigured and modified. Thereby, the base of case-based agile fixture design system info is established.Whole case-based agile fixture design model is presented. In which, three modules are added relative to the other models, including case matching of fixture planning module, conflict arbitration module and agile fixture case modify module. The three modules could solve the previous problem that the experience and result are difficult to be reused in the process of design.Two key techniques in the process of the agile fixture design, the evaluation of case similarity, and restriction-based conflict arbitration, are listed. And some methods are presented to evaluate the similarity and clear up the conflict.

  8. Dosimetric studies of the eye lens using a new dosemeter – Surveys in interventional radiology departments

    International Nuclear Information System (INIS)

    Pirchio, R.; Sánchez, H.; Domazet, W.

    2014-01-01

    During interventional radiology (IR) and cardiology (IC) procedures, medical staff can receive high doses to their eye lenses. The Retrospective Evaluation of Lens Injuries and Dose study organized in Argentina in 2010 found incipient opacity in 50% of IC physicians and 41% of IC technicians/nurses. These results, added to the recommendations of the International Commission on Radiological Protection, which lowered their former occupational equivalent dose limit for the lens, led us to assess the eye lens dose, Hp(3), during interventional procedures. To this end, a new dosemeter was designed and calibrated at the National Atomic Energy Commission of Argentina to evaluate Hp(3). Personal dose equivalent (Hp(10)), and Hp(3) were assessed for 3 months in two IC and IR departments. An Alderson phantom was used to simulate monthly exposures of five occupational staff members. Hp(3) and Hp(10) were obtained monthly for 14 occupational staff members exposed to 121 IR and IC procedures. We concluded that the annual effective dose and Hp(3) were lower than 0.3 and 10 mSv, respectively and the average cumulative Hp(3) for working life was lower than 400 and 200 mSv for physicians and technicians/scrub nurse, respectively. An occupational annual dose constraint of 0.3 mSv was calculated. - Highlights: • An eye lens dosimeters was designed at the Personal Dosimetry Laboratory of CNEA. • A successful dosimetric survey in two interventional departments was done. • The annual effective dose and the annual eye lens dose are lower than the ICRP dose thresholds. • In order to reduce doses actions should be promoted to maximize radiation protection

  9. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co{sub 60}; Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte I. Estudio de la homogeneidad de la respuesta dosimetros personales (tarjetas G-1, TLD-100), en campos de radiacion de Co{sub 60}

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm{sup -2} of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn{sup t} exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with

  10. Plant aging and design bases documentation

    International Nuclear Information System (INIS)

    Kelly, J.

    1985-01-01

    As interest in plant aging and lifetime extension continues to grow, the need to identify and capture the original design bases for the plant becomes more urgent. Decisions on lifetime extension and availability must be based on a rational understanding of design input, assumptions, and objectives. As operating plant time accumulates, the history of the early design begins to fade. The longer the utility waits, the harder it will be to re-establish the original design bases. Therefore, the time to develop this foundation is now. This paper demonstrates the impact that collecting and maintaining the original design bases of the plant can have on a utility's lifetime extension program. This impact becomes apparent when considering the technical, regulatory and financial aspects of lifetime extension. It is not good enough to know that the design information is buried somewhere in the corporate archives, and that given enough time, it could be retrieved. To be useful to the lifetime extension program, plant design information must be concise, readily available (i.e., retrievable), and easy to use. These objectives can only be met through a systematic program for collecting and presenting plant design documentation. To get the maximum benefit from a lifetime extension program, usable design bases documentation should be available as early in the plant life as possible. It will help identify areas that require monitoring today so that data is available to make rational decisions in the future

  11. Fourth intercomparison of personal dosemeters used in US Department of Energy accelerator facilities

    CERN Document Server

    Stewart, R D; Otto, T; Loesch, R M

    2000-01-01

    Personal neutron dosemeters from seven US Department of Energy (DOE) laboratories were mailed to the European Laboratory for Particle Physics (CERN) and irradiated using the well-characterised CERN reference radiation facility (CERF). Neutron dose equivalents determined using the DOE personal dosemeters have been compared to the reference dose equivalent as determined using a tissue-equivalent proportional counter (TEPC). In the 0.5 to 5 mSv dose equivalent range, the comparison of results suggests that the neutron personal dosemeters in use at DOE facilities are capable of estimating dose equivalents for high energy neutrons to within a factor of at least 2 or 3. If a field-specific calibration factor is used to correct the dose equivalent responses, the agreement with the reference dose equivalent for these dosemeters can be improved to better than about 25 to 65at is decoupled from the core in /sup 183,185/Au, becomes the 3/2[532] state (h9/2 parentage) strongly coupled in the doubly-odd /sup 184/Au nucleu...

  12. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin V, J.C.; Falcony, C.; Azorin N, J.

    2000-01-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  13. Effect of some parameters in the response of the Perspex 3042, Lot L amber dosemeters

    International Nuclear Information System (INIS)

    Prieto M, E.F.; Barrera G, G.

    2004-01-01

    The answer of the dosimetric systems is affected by several factors, for what should know as these factors they influence in each one of the different dosimetric systems and by this way to minimize its effect in the value of the absorbed dose and to obtain exact dose values. One of the dosimetric systems more used in the high dose dosimetry like routine dosemeter for the control of the irradiation process are the Perspex dosemeters, for their speed in the obtaining the information, their easy manipulation and the precision that they present. To this dosemeters group they belong the same as the Red and Clear the Amber, which are adequate for the measurement of the radiation dose in the range of high doses. The objective of the present work is to obtain the calibration curves of the dosemeters Amber Perspex 3042, Lot L under our work conditions, like they are the irradiation temperatures and of storage and to know the influence of the rate dose in the value of the absorbed dose for different measurement wavelengths, as well as, the relationship among the one post-irradiation time and the specific absorbance value induced in function of the absorbed dose. (Author)

  14. A measurement of the response to fast neutrons of several materials dosemeters

    International Nuclear Information System (INIS)

    Jones, L.T.; Kitching, S.J.; Lewis, T.A.; Playle, T.S.

    1986-07-01

    The response to fast neutrons was measured for three types of materials testing dosemeters: fast neutron dosimetry silicon diodes; beryllia, alumina and calcium fluoride TLDs; graphite walled ionisation chambers. The calibrations were made using a 3MW positive ion accelerator. The arrangement of the target, beam monitor and devices is described, and the measured fast neutron sensitivities are presented. (UK)

  15. Determination of the parameters of traps in thermoluminescent dosemeters of ZrO2: Eu + Ptfe

    International Nuclear Information System (INIS)

    Nieto H, B.; Azorin N, J.; Rivera M, T.

    2002-01-01

    In this work the manufacture of dosemeters in pellets form of ZrO 2 : Eu + Ptfe is described; which after were exposed to UV radiation (260 nm) were generated the corresponding thermoluminescent curves and in the basis to the properties of symmetry of the curves it was determined the kinetic order using the Chen and the Balarin criteria. (Author)

  16. Thermoluminescent dosemeters (TLD) exposed to high fluxes of gamma radiation, thermal neutrons and protons

    International Nuclear Information System (INIS)

    Gambarini, G.; Martini, M.; Meinardi, F.; Raffaglio, C.; Salvadori, P.; Scacco, A.; Sichirollo, A.E.

    1996-01-01

    Thermoluminescent dosemeters (TLD), widely experimented and utilized in personal dosimetry, have some advantageous characteristics which induce one to employ them also in radiotherapy. The new radiotherapy techniques are aimed at selectively depositing a high dose in cancerous tissues. This goal is reached by utilising both conventional and other more recently proposed radiation, such as thermal neutrons and heavy charged particles. In these inhomogeneous radiation fields a reliable mapping of the spatial distribution of absorbed dose is desirable, and the utilized dosemeters have to give such a possibility without notably perturbing the radiation field with the materials of the dosemeters themselves. TLDs, for their small dimension and their tissue equivalence for most radiation, give good support in the mapping of radiation fields. After exposure to the high fluxes of therapeutic beams, some commercial TL dosemeters have shown a loss of reliability. An investigation has therefore be performed, both on commercial and on laboratory made phosphors, in order to investigate their behaviour in such radiation fields. In particular the thermal neutron and gamma ray mixed field of the thermal column of a nuclear reactor, of interest for Boron Neutron Capture Therapy (B.N.C.T.) and a proton beam, of interest for proton therapy, were considered. Here some results obtained with new TL phosphors exposed in such radiation fields are presented, after a short description of some radiation damage effect on commercial LiF TLDs exposed in the (n th ,γ) field of the thermal column of a reactor. (author)

  17. Rationale for reduced tornado design bases

    International Nuclear Information System (INIS)

    Rutherford, P.D.; Ho, H.W.; Hartung, J.A.; Kastenberg, W.E.

    1985-01-01

    This paper provides a rationale for relaxing the present NRC tornado design requirements, which are based on a design basis tornado (DBT) whose frequency of exceedance is 10 -7 per year. It is proposed that a reduced DBT frequency of 10 -5 to 10 -6 per year is acceptable. This change in the tornado design bases for LMFBRs (and possibly all types of nuclear plants) is justified based on (1) existing NRC regulations and guidelines, (2) probabilistic arguments, (3) consistency with NRC trial safety goals, and (4) cost-benefit analysis

  18. Norm based design of fault detectors

    DEFF Research Database (Denmark)

    Rank, Mike Lind; Niemann, Hans Henrik

    1999-01-01

    The design of fault detectors for fault detection and isolation (FDI) in dynamic systems is considered in this paper from a norm based point of view. An analysis of norm based threshold selection is given based on different formulations of FDI problems. Both the nominal FDI problem as well...

  19. Capturing the design bases on Palo Verde

    International Nuclear Information System (INIS)

    Rogers, A.C.; Prawlocki, F.C.

    1989-01-01

    Over the past several years, the nuclear power industry has been directing considerable attention to plant configuration control. Utilities have been put in difficult situations due to changes made in plants without full original design basis knowledge. Once a plant is constructed, there is often insufficient information from the reactor designer or the architect/engineer to properly support operations, especially changes to the plant. In many cases utilities do not know the design bases for their units. As a result of these concerns, many utilities have been searching for ways to define the appropriate design bases for their plant. This paper discusses steps taken by Palo Verde to produce a design bases document and how it is being used to support the operation of the three nuclear units

  20. The design philosophy for an automatic TLD system to meet current international specifications

    International Nuclear Information System (INIS)

    Haaslahti, J.

    1986-01-01

    The object of this paper is to describe the elements of a new automatic TLD system intended to meet draft IEC/ISO proposals and ANSI requirements in the USA. Dosemeter badge design is based on ICRU recommendations. The basic intent has been to produce a standard system that can measure and file raw data that can be adapted to specific user requirements with software. The system consists of a programmable automatic reader, an automatic irradiator, a computer, and dosemeters for environmental, whole body, extremity, and clinical applications. The reader uses hot nitrogen heating and photon counting, and measurement conditions may be chosen with complete freedom. The reader can produce a real-time glow curve to assist in checking performance. The irradiator has a 90 Sr- 90 Y source to permit programmed irradiation for calibration and material sensitivity checks. Cassettes are used to hold TLD cards during processing. Cassette coding both identifies samples and calls measurement parameters into use from memory. The system can be preprogrammed to measure all common materials and all common dosemeter elements (both square and round). (author)

  1. Designers' Cognitive Thinking Based on Evolutionary Algorithms

    OpenAIRE

    Zhang Shutao; Jianning Su; Chibing Hu; Peng Wang

    2013-01-01

    The research on cognitive thinking is important to construct the efficient intelligent design systems. But it is difficult to describe the model of cognitive thinking with reasonable mathematical theory. Based on the analysis of design strategy and innovative thinking, we investigated the design cognitive thinking model that included the external guide thinking of "width priority - depth priority" and the internal dominated thinking of "divergent thinking - convergent thinking", built a reaso...

  2. Fiber-optic-coupled dosemeter for remote optical sensing of radiation

    International Nuclear Information System (INIS)

    Justus, B.L.; Huston, A.L.

    1996-01-01

    Remote sensing technologies for the detection and measurement of ionizing radiation exposure are of current interest for applications such as patient dose verification during radiotherapy and the monitoring of environmental contaminants. Fiberoptic-based sensing is attractive due to the advantages of small size, low cost, long life and freedom from electromagnetic interference. Several fiberoptic-based radiation sensing systems have been described that utilize radiation induced changes in the optical characteristics of the fiber such as reduced transmission as a result of darkening of the glass, optical phase shifts due to heating, or changes in the birefringence of a polarization-maintaining fiber. The measurement of radiation induced darkening is limited in both sensitivity and dynamic range and requires long fiber lengths. Phase shift measurements require the use of single-mode lasers, phase sensitive interferometric detection, long fiber lengths and complex signal processing techniques. Alternatively, thermoluminescent (TL) phosphor powders have been coated onto fiberoptic cables and remote dosimetry measurements performed using traditional laser heating techniques. The sensitivity is limited by the requirement for a very thin layer of phosphor material, due to problems associated with light scattering and efficient heating by thermal diffusion. In this paper we report the development of an all-optical, fiber-optic-coupled, thermoluminescence dosemeter for remote radiation sensing that offers significant advantages compared to previous technologies. We recently reported the development of an optically transparent, TL glass material having exceptionally good characteristics for traditional dosimetry applications. We also reported a modified TL glass incorporating a rare earth ion dopant in order to absorb light from a semiconductor laser and utilize the absorbed light energy to internally heat the glass and release the trapped electrons. (author)

  3. Design and qualification of HPD based designs for safety systems

    International Nuclear Information System (INIS)

    Sharma, Mukesh Kr.; Chavan, Madhavi A.; Sawhney, Pratibha A.; Mohanty, Ashutos; John, Ajith K.; Ganesh, G.

    2014-01-01

    Field Programmable Gate Arrays (FPGA) and Complex Programmable Logic Devices (CPLD) are increasingly being used in C and I system of NPPs. The function of such an integrated circuit is not defined by the supplier of the physical component or micro-electronic technology but by the C and I designer. The hardware subsystems implemented in these devices typically use Hardware Description Language (HDL) like VHDL or Verilog to describe the functionality at the design entry level. These circuits are commonly known as 'HDL-Programmed Devices', (HPD). RCnD has developed a set of hardware boards to be used in next generation C and I systems. The boards have been designed based on present day technology and components. The intelligence of these boards has been implemented in HPDs (FPGA/CPLD) using VHDL. Since these boards are used in the safety and safety related systems, they have undergone a rigorous V and V process and qualification tests. This paper discusses the design attributes and qualification of these HPD based designs for nuclear class safety systems. (author)

  4. Design Criteria Based on Aesthetic Considerations

    DEFF Research Database (Denmark)

    Thomsen, Bente Dahl

    2009-01-01

    Aesthetic criteria for designs are often debated in a very subjective manner which makes it difficult to reach consensus. In order to have a more rational and transparent process, in particular in industrial design, we propose a procedure based on Baumgarten's aesthetic considerations and Thommesen......'s dividing of a form into form elements. The procedure has been tested in student projects....

  5. Overview of Performance Based Practical Design

    Science.gov (United States)

    2018-03-01

    DOI: https://doi.org/10.13023/KTC.RR.2018.03 State transportation agencies (STAs) have increasingly turned to practical design and performance based practical design(PBPD) to inform project development and implementation and to reduce project cos...

  6. Experiences in Preserving Design Bases & Knowledge Management

    International Nuclear Information System (INIS)

    Koshy, Thomas

    2013-01-01

    Purpose: • To build repository of information on design and development in a retrievable manner to: • Establish licensing/design bases of the plant; • Identify the known vulnerabilities and how they are to be addressed; • Prevent undoing the lessons learned; • Facilitate advancement without repeating the undesirable incidents of the past

  7. Multimedia-Based Chip Design Education.

    Science.gov (United States)

    Catalkaya, Tamer; Golze, Ulrich

    This paper focuses on multimedia computer-based training programs on chip design. Their development must be fast and economical, in order to be affordable by technical university institutions. The self-produced teaching program Illusion, which demonstrates a monitor controller as an example of a small but complete chip design, was implemented to…

  8. Performance-based Pareto optimal design

    NARCIS (Netherlands)

    Sariyildiz, I.S.; Bittermann, M.S.; Ciftcioglu, O.

    2008-01-01

    A novel approach for performance-based design is presented, where Pareto optimality is pursued. Design requirements may contain linguistic information, which is difficult to bring into computation or make consistent their impartial estimations from case to case. Fuzzy logic and soft computing are

  9. SLS Model Based Design: A Navigation Perspective

    Science.gov (United States)

    Oliver, T. Emerson; Anzalone, Evan; Park, Thomas; Geohagan, Kevin

    2018-01-01

    The SLS Program has implemented a Model-based Design (MBD) and Model-based Requirements approach for managing component design information and system requirements. This approach differs from previous large-scale design efforts at Marshall Space Flight Center where design documentation alone conveyed information required for vehicle design and analysis and where extensive requirements sets were used to scope and constrain the design. The SLS Navigation Team is responsible for the Program-controlled Design Math Models (DMMs) which describe and represent the performance of the Inertial Navigation System (INS) and the Rate Gyro Assemblies (RGAs) used by Guidance, Navigation, and Controls (GN&C). The SLS Navigation Team is also responsible for navigation algorithms. The navigation algorithms are delivered for implementation on the flight hardware as a DMM. For the SLS Block 1B design, the additional GPS Receiver hardware model is managed as a DMM at the vehicle design level. This paper describes the models, and discusses the processes and methods used to engineer, design, and coordinate engineering trades and performance assessments using SLS practices as applied to the GN&C system, with a particular focus on the navigation components.

  10. Evaluation of dose equivalent and identification of energy rangeby the electronic personal dosemeter for neutron 'Saphydose-N' at different workplaces of nuclear facilities

    International Nuclear Information System (INIS)

    Chau, Q.; Lahaye, T.; Lacoste, V.; Muller, H.; Luszik-Bhadra, M.; Reginatto, M.

    2005-01-01

    Full text: According to the transposition of the Directive 96/29/EURATOM into the French legislation, any worker operating in a controlled area has to be monitored by 'passive' and 'active' dosemeters. Electronic personal dosemeters are especially needed for optimization of workplaces. In nuclear facilities, some of the workers are likely to be exposed to mixed neutron-photon fields. If the dosimetry of the photons is relatively well controlled, the neutron dosimetry raises more difficulties. In this context, the Institute for Radiological Protection and Nuclear Safety (IRSN) has developed an electronic device based on a silicon detector: the 'Saphydose-N' dosemeter. It is composed of several detectors and covers more than eight energy decades. The Saphydose-N device complies with recommendations of standard IEC 1323. As the radiation fields produced in laboratory are not strictly representative to those encountered at workplaces, IRSN evaluated the response of Saphydose-N at various workplaces from nuclear industry. Several campaigns were performed in the framework of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). Saphydose-N was carried out at a fuel processing plant, at the Nuclear Power Plant close to the boiling water reactor, near the transport and storage cask and at the Research Reactor. This paper mainly aims at presenting the measurements, the identification of the energy range and the results obtained with the electronic personal neutron Saphydose-N at different facilities. The results are compared with reference values, defined by other partners in EVIDOS project, for ambient and personal dose equivalent. (author)

  11. Model-Based Requirements Management in Gear Systems Design Based On Graph-Based Design Languages

    Directory of Open Access Journals (Sweden)

    Kevin Holder

    2017-10-01

    Full Text Available For several decades, a wide-spread consensus concerning the enormous importance of an in-depth clarification of the specifications of a product has been observed. A weak clarification of specifications is repeatedly listed as a main cause for the failure of product development projects. Requirements, which can be defined as the purpose, goals, constraints, and criteria associated with a product development project, play a central role in the clarification of specifications. The collection of activities which ensure that requirements are identified, documented, maintained, communicated, and traced throughout the life cycle of a system, product, or service can be referred to as “requirements engineering”. These activities can be supported by a collection and combination of strategies, methods, and tools which are appropriate for the clarification of specifications. Numerous publications describe the strategy and the components of requirements management. Furthermore, recent research investigates its industrial application. Simultaneously, promising developments of graph-based design languages for a holistic digital representation of the product life cycle are presented. Current developments realize graph-based languages by the diagrams of the Unified Modelling Language (UML, and allow the automatic generation and evaluation of multiple product variants. The research presented in this paper seeks to present a method in order to combine the advantages of a conscious requirements management process and graph-based design languages. Consequently, the main objective of this paper is the investigation of a model-based integration of requirements in a product development process by means of graph-based design languages. The research method is based on an in-depth analysis of an exemplary industrial product development, a gear system for so-called “Electrical Multiple Units” (EMU. Important requirements were abstracted from a gear system

  12. SLS Navigation Model-Based Design Approach

    Science.gov (United States)

    Oliver, T. Emerson; Anzalone, Evan; Geohagan, Kevin; Bernard, Bill; Park, Thomas

    2018-01-01

    The SLS Program chose to implement a Model-based Design and Model-based Requirements approach for managing component design information and system requirements. This approach differs from previous large-scale design efforts at Marshall Space Flight Center where design documentation alone conveyed information required for vehicle design and analysis and where extensive requirements sets were used to scope and constrain the design. The SLS Navigation Team has been responsible for the Program-controlled Design Math Models (DMMs) which describe and represent the performance of the Inertial Navigation System (INS) and the Rate Gyro Assemblies (RGAs) used by Guidance, Navigation, and Controls (GN&C). The SLS Navigation Team is also responsible for the navigation algorithms. The navigation algorithms are delivered for implementation on the flight hardware as a DMM. For the SLS Block 1-B design, the additional GPS Receiver hardware is managed as a DMM at the vehicle design level. This paper provides a discussion of the processes and methods used to engineer, design, and coordinate engineering trades and performance assessments using SLS practices as applied to the GN&C system, with a particular focus on the Navigation components. These include composing system requirements, requirements verification, model development, model verification and validation, and modeling and analysis approaches. The Model-based Design and Requirements approach does not reduce the effort associated with the design process versus previous processes used at Marshall Space Flight Center. Instead, the approach takes advantage of overlap between the requirements development and management process, and the design and analysis process by efficiently combining the control (i.e. the requirement) and the design mechanisms. The design mechanism is the representation of the component behavior and performance in design and analysis tools. The focus in the early design process shifts from the development and

  13. Reliability based Design of Coastal Structures

    DEFF Research Database (Denmark)

    Burcharth, H. F.

    2003-01-01

    Conventional design practice for coastal structures is deterministic in nature and is based on the concept of a design load which should not exceed the resistance (carrying capacity) of the structure. The design load is usually defined on a probabilistic basis as a characteristic value of the load......, for example the expectation (mean) value of the 100-year return period event. However, this selection is often made without consideration of the involved uncertainties. In most cases the resistance is defined in terms of the load that causes a certain design impact or damage to the structure...

  14. Web-based Core Design System Development

    International Nuclear Information System (INIS)

    Moon, So Young; Kim, Hyung Jin; Yang, Sung Tae; Hong, Sun Kwan

    2011-01-01

    The selection of a loading pattern is one of core design processes in the operation of a nuclear power plant. A potential new loading pattern is identified by selecting fuels that to not exceed the major limiting factors of the design and that satisfy the core design conditions for employing fuel data from the existing loading pattern of the current operating cycle. The selection of a loading pattern is also related to the cycle plan of an operating nuclear power plant and must meet safety and economic requirements. In selecting an appropriate loading pattern, all aspects, such as input creation, code runs and result processes are processed as text forms manually by a designer, all of which may be subject to human error, such as syntax or running errors. Time-consuming results analysis and decision-making processes are the most significant inefficiencies to avoid. A web-based nuclear plant core design system was developed here to remedy the shortcomings of an existing core design system. The proposed system adopts the general methodology of OPR1000 (Korea Standard Nuclear Power Plants) and Westinghouse-type plants. Additionally, it offers a GUI (Graphic User Interface)-based core design environment with a user-friendly interface for operators. It reduces human errors related to design model creation, computation, final reload core model selection, final output confirmation, and result data validation and verification. Most significantly, it reduces the core design time by more than 75% compared to its predecessor

  15. Bodystorming for Movement-Based Interaction Design

    Directory of Open Access Journals (Sweden)

    Elena Márquez Segura

    2016-11-01

    Full Text Available After a decade of movement-based interaction in human–computer interaction, designing for the moving body still remains a challenge. Research in this field requires methods to help access, articulate, and harness embodied experiences in ways that can inform the design process. To address this challenge, this article appropriates bodystorming, an embodied ideation method for movement-based interaction design. The proposed method allows for early consideration of the physical, collocated, and social aspects of a designed activity as illustrated with two explorative workshops in different application domains: interactive body games and interactive performances. Using a qualitative methods approach, we used video material from the workshops, feedback from participants, and our own experience as participants and facilitators to outline important characteristics of the bodystorming method in the domain of movement-based interaction. The proposed method is compared with previous ones and application implications are discussed.

  16. Competency Based Assessment in Fashion Design

    Science.gov (United States)

    Russanti, Irma; Nurlaela, Lutfiyah; Basuki, Ismet; Munoto

    2018-04-01

    Professional certification is a form of stipulation on certain competency standards provided by one professional organization to the performance of a person through assessment. For that an assessment needs to be standardized so that there exists a general standardized scale to measure competence. In the professional certification of fashion design department, an instrument of competency based assessment is essential to be developed. The purpose of this review is to know the application of competency based assessment in the field of fashion design. The literature reviews were found by journal searching with keywords competency based assessment and fashion design in Google scholar, of which was gotten over 20 journals from 2006 to 2016. Afterwards, the search of the free-downloaded e-books in libgen was conducted under competency based assessment and fashion design, which is then found some related references. The obtained literatures were used to review the definition, approach, and implementation of competency based assessment in the field of fashion design. Results show that it is important to develop an assessment sheet in the field of fashion design covering garment, apparel and embroidery sectors by patterning the criteria of performers along with the qualifications.

  17. Research-based design & design-based research: Affordances, limitations and synergies

    NARCIS (Netherlands)

    McKenney, Susan

    2015-01-01

    Research-based design is an orientation to educational development that is explicitly informed by existing research as well as formative evaluation. Design-based research is a genre of inquiry in which the design of innovative solutions to problems in educational practice provides the context for

  18. Energy dependence of ulrathin LiF-dosemeters for high energy electrons and high energy X-radiation

    International Nuclear Information System (INIS)

    Kupfer, T.

    1977-02-01

    The energy dependence of ultrathin LiF-dosemeters for high energy electrons (5-40 MeV) and high energy X-radiation (6 MV, 42 MV) is experimentally determined. The experimental values are compared to values calculted earlier by other authors. The influence of the thickness of the dosemeters have been considered by comparison of experimental values for 0.03 mm thick dosemeters and theoretical values for 0.13 mm and 0.38 mm thick ones. Also different commersially available dosemeters have been compared by experiments. It is difficult to draw any other conclutions about the energy dependence than that the variation of the relative responce is within +- 3 percent (2S). However the results seems to be sulficient for clinical applications

  19. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry

    International Nuclear Information System (INIS)

    Fiechtner, A.; Boschung, M.; Wernli, C.

    2007-01-01

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields. The measured personal neutron dose equivalents of the PADC personal neutron dosemeter are compared with values that were assessed within the EVIDOS project by other partners. The detection limits for different spectra types are given. In cases were the neutron dose was too low to be measured by the PADC personal neutron dosemeter, the response is estimated by convoluting the responses to monoenergetic neutrons with the dose energy distribution measured within EVIDOS. The advantages and limitations of the PADC personal neutron dosemeter are discussed. (authors)

  20. Design for game based learning platforms

    DEFF Research Database (Denmark)

    Sørensen, Birgitte Holm; Meyer, Bente

    2010-01-01

    This paper focuses on the challenges related to the design of game based learning platforms for formal learning contexts that are inspired by the pupil's leisure time related use of web 2.0. The paper is based on the project Serious Games on a Global Market Place (2007-2011) founded by the Danish...... of web 2.0 and integrates theories of learning, didactics, games, play, communication, multimodality and different pedagogical approaches. In relation to the introduced model the teacher role is discussed.......This paper focuses on the challenges related to the design of game based learning platforms for formal learning contexts that are inspired by the pupil's leisure time related use of web 2.0. The paper is based on the project Serious Games on a Global Market Place (2007-2011) founded by the Danish...... Council for Strategic Research, in which an online game-based platform for English as a foreign language in primary school is studied. The paper presents a model for designing for game based learning platforms. This design is based on cultural and ethnographic based research on children's leisure time use...

  1. Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.; Horwood, N.

    1999-01-01

    A study has been performed to assess the extent to which variations in the energy dependence of response of neutron personal dosemeters can cause systematic errors in readings obtained in workplace fields. This involved a detailed determination of the response functions of personal dosemeters used in the UK. These response functions were folded with workplace spectra to ascertain the under- or over-response in workplace fields

  2. Systematic errors in the readings of track etch neutron dosemeters caused by the energy dependence of response

    CERN Document Server

    Tanner, R J; Bartlett, D T; Horwood, N

    1999-01-01

    A study has been performed to assess the extent to which variations in the energy dependence of response of neutron personal dosemeters can cause systematic errors in readings obtained in workplace fields. This involved a detailed determination of the response functions of personal dosemeters used in the UK. These response functions were folded with workplace spectra to ascertain the under- or over-response in workplace fields.

  3. Implementing a Generative Urban Design Model : Grammar-based design patterns for urban design

    NARCIS (Netherlands)

    Beirao, J.N.; Mendes, G.; Duarte, J.; Stouffs, R.M.F.

    2010-01-01

    This paper shows the first results of a prototype implementation of a generative urban design tool. This implementation will form part of a design support tool for a GIS based platform defined to formulate, generate and evaluate urban designs. These three goals, formulation, generation and

  4. Comparative measurements of external radiation exposure using mobile phones, dental ceramic, household salt and conventional personal dosemeters

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Bulánek, Boris; Judas, Libor

    2015-01-01

    Because retrospective dosimetry utilises commonly occurring materials and objects, it is particularly useful in cases of large-scale radiation accidents or malevolent acts with radioactive materials where casualties are inflicted on the general public and first emergency responders. The aim of this study was to investigate whether retrospective dosemeters can provide dose estimates with comparable accuracy like conventional personal dosemeters. Using an external source of radiation 137 Cs and an anthropomorphic phantom, we simulated serious irradiation of a human body in anterior-posterior and rotational geometries. Retrospective luminescence dosimetry objects, such as mobile phones, dental ceramic and household salt, and conventional personal dosemeters (thermoluminescent and electronic) were fixed to the anthropomorphic phantom. The doses obtained were compared with specific reference values. In most cases, relative deviations between the measured doses and the reference values did not exceed 20%. As the retrospective and conventional dosemeters show no significant differences in laboratory conditions, the retrospective luminescence dosimetry objects represent a very promising tool if handled properly. - Highlights: • A serious external exposure of human body was simulated. • Doses were measured using both retrospective and conventional dosemeters. • Utilised retrospective dosimetry materials were alumina resistors from mobile phones, household salt and dental ceramic. • Doses obtained were compared with reference values. • Both retrospective and conventional dosemeters gave similar results

  5. Aggregation Operator Based Fuzzy Pattern Classifier Design

    DEFF Research Database (Denmark)

    Mönks, Uwe; Larsen, Henrik Legind; Lohweg, Volker

    2009-01-01

    This paper presents a novel modular fuzzy pattern classifier design framework for intelligent automation systems, developed on the base of the established Modified Fuzzy Pattern Classifier (MFPC) and allows designing novel classifier models which are hardware-efficiently implementable....... The performances of novel classifiers using substitutes of MFPC's geometric mean aggregator are benchmarked in the scope of an image processing application against the MFPC to reveal classification improvement potentials for obtaining higher classification rates....

  6. Visualizing Practices in Project-based Design

    DEFF Research Database (Denmark)

    Whyte, Jennifer; Tryggestad, Kjell; Comi, Alice

    2016-01-01

    Project-based design involves a variety of visual representations, which are evolved to make decisions and accomplish project objectives. Yet, such mediated and distributed ways of working are difficult to capture through ethnographies that examine situated design. A novel approach is developed t...... representations enabled participants in project-based design to develop and share understanding. The complexity of projects and their distributed and mediated nature makes this approach timely and important in addressing new research questions and practical challenges.......Project-based design involves a variety of visual representations, which are evolved to make decisions and accomplish project objectives. Yet, such mediated and distributed ways of working are difficult to capture through ethnographies that examine situated design. A novel approach is developed...... of situated design. This allows the researcher to be nimble, tracing connections across complex engineering projects; reconstructing practices through their visual representations; and observing their effects. Second, it articulates how, in these empirical cases, interaction with a cascade of visual...

  7. Computer vision based room interior design

    Science.gov (United States)

    Ahmad, Nasir; Hussain, Saddam; Ahmad, Kashif; Conci, Nicola

    2015-12-01

    This paper introduces a new application of computer vision. To the best of the author's knowledge, it is the first attempt to incorporate computer vision techniques into room interior designing. The computer vision based interior designing is achieved in two steps: object identification and color assignment. The image segmentation approach is used for the identification of the objects in the room and different color schemes are used for color assignment to these objects. The proposed approach is applied to simple as well as complex images from online sources. The proposed approach not only accelerated the process of interior designing but also made it very efficient by giving multiple alternatives.

  8. Data base systems in electronic design engineering

    Science.gov (United States)

    Williams, D.

    1980-01-01

    The concepts of an integrated design data base system (DBMS) as it might apply to an electronic design company are discussed. Data elements of documentation, project specifications, project tracking, firmware, software, electronic and mechanical design can be integrated and managed through a single DBMS. Combining the attributes of a DBMS data handler with specialized systems and functional data can provide users with maximum flexibility, reduced redundancy, and increased overall systems performance. Although some system overhead is lost due to redundancy in transitory data, it is believed the combination of the two data types is advisable rather than trying to do all data handling through a single DBMS.

  9. Justifying Design Decisions with Theory-based Design Principles

    OpenAIRE

    Schermann, Michael;Gehlert, Andreas;Pohl, Klaus;Krcmar, Helmut

    2014-01-01

    Although the role of theories in design research is recognized, we show that little attention has been paid on how to use theories when designing new artifacts. We introduce design principles as a new methodological approach to address this problem. Design principles extend the notion of design rationales that document how a design decision emerged. We extend the concept of design rationales by using theoretical hypotheses to support or object to design decisions. At the example of developing...

  10. Characterization of a two-component thermoluminescent albedo dosemeter according to ISO 21909

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M., E-mail: marcelo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Mauricio, C.L.P., E-mail: claudia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Silva, A.X. da, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao em Engenharia, COPPE/PEN Caixa Postal 68509, CEP 21941-972, Rio de Janeiro, RJ (Brazil)

    2011-05-15

    A two-component thermoluminescent albedo neutron monitoring system was developed at Instituto de Radioprotecao e Dosimetria, Brazil. As there is no Brazilian regulation for neutron individual monitoring service, the system was tested according to the ISO 21909 standard. This standard provides performance and test requirements for determining the acceptability of personal neutron dosemeters to be used for the measurement of personal dose equivalent, H{sub p}(10), in neutron fields with energies ranging from thermal to 20 MeV. Up to 40 dosemeters were used in order to accomplish satisfactorily the requirements of some tests. Despite operational difficulties, this albedo system passed all ISO 21909 performance requirements. The results and problems throughout this characterization are discussed in this paper.

  11. Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters.

    Science.gov (United States)

    Becková, Vera; Malátová, Irena

    2008-01-01

    Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolní Rozínka' at Rozná, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.

  12. Influence of different types of phantoms on the calibration of dosemeters for eye lens dosimetry

    International Nuclear Information System (INIS)

    Yoshitomi, H.; Kowatari, M.

    2016-01-01

    Both a cylinder and a slab phantom have been recommended to be used as calibration phantoms for eye lens dosimetry in the International Atomic Energy Agency TECDOC. This study describes investigations on the influence of the type of phantom on the calibration of dosemeters. In order to fulfil the purpose, backscatter radiation from practically used water-filled phantoms was evaluated by calculations and experiments. For photons, the calculations showed that the cylinder phantom had 10 % lower backscattered effect at maximum than a slab phantom, and simulated well the backscattered effect of the human head or neck to within ±10 %. The irradiation results of non-filtered optically stimulated luminescence and radio-photoluminescence glass dosemeters indicated that the differences of the calibration factors between the two types of phantoms were up to 20 and 10 %, respectively, reflecting the response to backscattered photons. For electrons, no difference was found between the two types of phantoms. (authors)

  13. Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters

    International Nuclear Information System (INIS)

    Beckova, V.; Malatova, I.

    2008-01-01

    Kinetics of dissolution of 238 U, 234 U and 230 Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultra-filtrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolni Rozinka' at Rozna, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h -1 and the sampling period is typically 1 month. Studied filters contained 125 ± 6 mBq 238 U in equilibrium with 234 U and 230 Th; no 232 Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for 238 U and 234 U and slow dissolution half-times of 173 and 116 d were found for 238 U and 234 U, respectively. No detectable dissolution of 230 Th was found. (authors)

  14. Measuring radiation exposure during percutaneous drainages: can shoulder dosemeters be used to estimate finger doses?

    International Nuclear Information System (INIS)

    Vehmas, Tapio; Tikkanen, Heikki

    1992-01-01

    To assess the need for extra finger dosemeters, radiologists' and assistants' radiation exposure at both shoulders and at the third fingers of both hands were recorded using thermoluminescent dosemeters during 27 interventional drainage procedures. Under couch screening was used. Mean dose rates were calculated by dividing dose by screening time. The radiologists' bilateral finger dose rates did not correlate with each other; nor did dose rates between the left shoulder and the right hand. The radiologists' dose rates at both shoulders, correlated with each other, as did shoulder dose rates with dose rates at the ispilateral hand. The right shoulder dose rates correlated with the left hand dose rates. The assistants' dose rates at places of measurement showed significant correlations with each other. (Author)

  15. Contribution to the development study of a personal fast neutron dosemeter using nuclear emulsion

    International Nuclear Information System (INIS)

    Ott, C.

    1985-02-01

    This work deals with the response of a personal neutron dosemeter using nuclear emulsion. The main characteristics of the detector are studied with the help of a computer programme simulating the conditions of the formation of recoil protons tracks recorded by nuclear emulsions. The lecture limits of nuclear emulsions with light microscope and the validity of our computer code are checked by comparing our theoretical values with experimental results [fr

  16. Exposure levels to radiation in a nuclear medicine laboratory: measurements with thermoluminescence dosemeters

    International Nuclear Information System (INIS)

    Ruiz J, A.

    2000-01-01

    Since 1996 in the Nuclear medicine Department and another routine and research departments of the National Institute of Medical and Nutrition Sciences (INCMNSZ) are working at least with 12 radioactive sources opened and sealed. However, it was unknown if with the Tl personal dosemeters with lithium fluoride crystals (LiF), could be possible to receive information about the equivalent dose for each radionuclide or if there was some radionuclide that by being low energy emissor or beta energy emissor, it did not represent an ionization power sufficient to excite the crystals of the thermoluminescent dosemeters (DTL). In this work the obtained results with control dosemeters of diverse source opened or sealed are shown, which were put at 1 cm of the LiF crystals during a time exposure 18 hours. Therefore the objective of this work is to verify which sources excite or not to DTL crystals and taking the pertinent safety measures for each radionuclide. The conclusion is that the majority of dosemeters were excited by beta or gamma radiation of the radionuclides and that LiF crystals are able to receive equivalent doses until 1200 mSv, being this a guarantee for the staff, that in an any moment could be exposed to high dose in his working day. Also it was corroborated that the radionuclides more energizer are: iodine-131, iodine-125 and sodium-22 while the phosphorus-32 must be managed with careful, since the exposure to hands can result significant, just like the technetium-99m ( 99m Tc). (Author)

  17. Possibility of the use of PVC plastics as a ray dosemeter

    International Nuclear Information System (INIS)

    Amri Ayat; Sutrisno Puspodikoro.

    1978-01-01

    The use of plastics as a radiation dosemeter for measurement of γ-rays is very attractive to be studied. In the work presented here commercial PVC film with the trade-mark ''Takiron'' is used for Co-60 radiation dosimetry. According to the experiments the useful dose range extends over 0.15-1.2 Mrads. Fading of the coloration with time after radiation exposure can be stabilised by heat treatment (60 deg C for 30 minutes). (author)

  18. Determination of the dose index in computerized tomography using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin, J.C.; Calderon, A.; Azorin, J.

    2004-01-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  19. Dose estimation by simultaneous measurement of the radon/thoron concentration and the equilibrium factors in air using a passive dosemeter

    International Nuclear Information System (INIS)

    Urban, M.

    1984-03-01

    Responsible for an increased radiation exposure is the inhalation of radon and its short lived daughters. A time integrating passive dosemeter was developed to determine the concentrations of the radon isotopes as well as their equilibrium factors. The α energy spectrum inside a dosemeter is measured by means of a nuclear track detector. The concentrations in air and the equilibrium factors are calculated by using a new mathematical dosemeter model. A small pilot study in houses was done to test the dosemeter. (orig.) [de

  20. Operational trials of single- and multi-element CR-39 dosemeters for the DIDO and PLUTO reactors at the Harwell Laboratory

    International Nuclear Information System (INIS)

    Gallacher, G.G.; Perks, C.A.

    1993-01-01

    Single- and multi-element CR-39 dosemeters, developed at the Harwell Laboratory, and a commercially available multi-element CR-39 dosemeter (obtained from Track Analysis Systems Ltd), were evaluated for their potential as neutron dosemeters for personnel working at Harwell Laboratory's research reactors. Owing to the angular dependence of the CR-39 (processed using electrochemical etching), the single-element dosemeter was found to be impractical. Consequently, a multi-element dosemeter was developed, which consisted of a cube of side 36 mm with CR-39 elements (also processed using electrochemical etching) attached to each of the sides. Although this dosemeter was technically suitable for this type of dosimetry, it was considered to be unacceptably bulky in personnel trials. The commercially available CR-39 dosemeter tested was much smaller (the CR-39 was only chemically etched) and this was considered to be acceptable as a personnel dosemeter. In addition, trials with personnel working at active handling glove boxes indicated that single-element dosemeters might be adequate, but further work would be needed to verify this. (author)

  1. Data base pertinent to earthquake design basis

    International Nuclear Information System (INIS)

    Sharma, R.D.

    1988-01-01

    Mitigation of earthquake risk from impending strong earthquakes is possible provided the hazard can be assessed, and translated into appropriate design inputs. This requires defining the seismic risk problem, isolating the risk factors and quantifying risk in terms of physical parameters, which are suitable for application in design. Like all other geological phenomena, past earthquakes hold the key to the understanding of future ones. Quantificatio n of seismic risk at a site calls for investigating the earthquake aspects of the site region and building a data base. The scope of such investigations is il lustrated in Figure 1 and 2. A more detailed definition of the earthquake problem in engineering design is given elsewhere (Sharma, 1987). The present document discusses the earthquake data base, which is required to support a seismic risk evaluation programme in the context of the existing state of the art. (author). 8 tables, 10 figs., 54 refs

  2. Performance testing of personal dosemeters from eleven dosimetry services in Sweden

    International Nuclear Information System (INIS)

    Lund, E.; Kylloenen, J.-E.; Grindborg, J.-E.; Lindborg, L.

    2001-01-01

    The Swedish regulation, SSI FS 98:5, requires that radiological workers of category A use dosemeters from an approved personal dosimetry service. The 11 services operating in Sweden at the moment use five different types of dosemeter. All have been tested for their ability to determine H p (10) and some of them to determine H p (0.07) according to the European Commission report Radiation Protection 73, EUR 14852, of 1994. The five unique systems have been tested regarding the angular and energy dependence of the response of the dosemeters. The test points for the determination of H p (10) are all, except one, within the trumpet curve and for the unique systems it is shown that the uncertainty related to angular response at three different energies is within the required ±40% except for the lowest X ray quality 40 kV. The energy dependence dominates over the directional dependence and the choice of radiation quality for calibration is of great importance for the system performance. (author)

  3. Evaluation of two personal dosemeters in polyenergetic mono- and multi-directional neutron fields

    International Nuclear Information System (INIS)

    Nunes, J. C.; Surette, R. A.

    2005-01-01

    The neutron dose-equivalent response of two commercially available electronic personal neutron dosemeters was studied in several laboratory-produced broad-spectrum neutron fields. Fluence-weighted mean energies ranged from 200 keV to 4 MeV; personal dose-equivalent rates ranged from 75 to 10 mSv h -1 ; and angles of incidence were multidirectional, 0 deg., 30 deg. and 60 deg.. Three of these fields have been shown previously to resemble ones found in CANDU (Canadian Deuterium Uranium is a registered trademark of the Atomic Energy of Canada Limited) power plant workplaces. Both dosemeters were found to perform reasonably well across the range of energy spectra and angles of incidence. One type of dosemeter displayed values of the personal dose equivalent that were, at worst, within a factor of ∼2 of the reference values and, at best, within a few per cent of the reference values. The other type displayed values of the personal dose equivalent that were consistently within unity and 20% of the reference values. Although the radiological performance of one was found to be more accurate, this device was also found to be the less rugged of the two. Some of the data acquired in this work were compared with results previously published by others. There was consistency between these sets of data. (authors)

  4. Facilitating Transition to Team Based Design Education

    DEFF Research Database (Denmark)

    Tollestrup, Christian

    2014-01-01

    profession, but at the same time it becomes very difficult to identify where and how the design is created since form-giving now becomes a group effort. So as a way to ease the transition from highly framed and facilitated high school learning context to university self-driven learning context a small...... given to two set of students; one set that received the survival kit in 2011 and 2012 and one set that did not. The questionnaire inquires the students’ attitude towards 4 aspects: 1.General level of preparedness for team and problem based project work 2.Level of information of expectations from...... supervisors and programme 3.Reflection of the role in a team, problem based project work 4.The level of information of special expectations from the Industrial Design program towards team and problem based project work. Results indicates that Class receiving the “Survival Kit” improved in the calibration...

  5. Design Concepts for Muon-Based Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ryne, R. D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Kirk, H. G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Palmer, R. B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stratkis, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Alexahin, Y. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Bross, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Gollwitzer, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Mokhov, N. V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Neuffer, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Palmer, M. A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Yonehara, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Snopok, P. [IIT, Chicago, IL (United States); Bogacz, A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Roberts, T. J. [Muons Inc., Batavia, IL (United States); Delahaye, J. -P. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-05-01

    Muon-based accelerators have the potential to enable facilities at both the Intensity and the Energy Frontiers. Muon storage rings can serve as high precision neutrino sources, and a muon collider is an ideal technology for a TeV or multi-TeV collider. Progress in muon accelerator designs has advanced steadily in recent years. In regard to 6D muon cooling, detailed and realistic designs now exist that provide more than 5 order-of-magnitude emittance reduction. Furthermore, detector performance studies indicate that with suitable pixelation and timing resolution, backgrounds in the collider detectors can be significantly reduced, thus enabling high-quality physics results. Thanks to these and other advances in design & simulation of muon systems, technology development, and systems demonstrations, muon storage-ring-based neutrino sources and a muon collider appear more feasible than ever before. A muon collider is now arguably among the most compelling approaches to a multi-TeV lepton collider. This paper summarizes the current status of design concepts for muon-based accelerators for neutrino factories and a muon collider.

  6. Design of LTCC Based Fractal Antenna

    KAUST Repository

    AdbulGhaffar, Farhan

    2010-09-01

    The thesis presents a Sierpinski Carpet fractal antenna array designed at 24 GHz for automotive radar applications. Miniaturized, high performance and low cost antennas are required for this application. To meet these specifications a fractal array has been designed for the first time on Low Temperature Co-fired Ceramic (LTCC) based substrate. LTCC provides a suitable platform for the development of these antennas due to its properties of vertical stack up and embedded passives. The complete antenna concept involves integration of this fractal antenna array with a Fresnel lens antenna providing a total gain of 15dB which is appropriate for medium range radar applications. The thesis also presents a comparison between the designed fractal antenna and a conventional patch antenna outlining the advantages of fractal antenna over the later one. The fractal antenna has a bandwidth of 1.8 GHz which is 7.5% of the centre frequency (24GHz) as compared to 1.9% of the conventional patch antenna. Furthermore the fractal design exhibits a size reduction of 53% as compared to the patch antenna. In the end a sensitivity analysis is carried out for the fractal antenna design depicting the robustness of the proposed design against the typical LTCC fabrication tolerances.

  7. Design Strategies for Aptamer-Based Biosensors

    Science.gov (United States)

    Han, Kun; Liang, Zhiqiang; Zhou, Nandi

    2010-01-01

    Aptamers have been widely used as recognition elements for biosensor construction, especially in the detection of proteins or small molecule targets, and regarded as promising alternatives for antibodies in bioassay areas. In this review, we present an overview of reported design strategies for the fabrication of biosensors and classify them into four basic modes: target-induced structure switching mode, sandwich or sandwich-like mode, target-induced dissociation/displacement mode and competitive replacement mode. In view of the unprecedented advantages brought about by aptamers and smart design strategies, aptamer-based biosensors are expected to be one of the most promising devices in bioassay related applications. PMID:22399891

  8. Interactive Reliability-Based Optimal Design

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle; Siemaszko, A.

    1994-01-01

    Interactive design/optimization of large, complex structural systems is considered. The objective function is assumed to model the expected costs. The constraints are reliability-based and/or related to deterministic code requirements. Solution of this optimization problem is divided in four main...... tasks, namely finite element analyses, sensitivity analyses, reliability analyses and application of an optimization algorithm. In the paper it is shown how these four tasks can be linked effectively and how existing information on design variables, Lagrange multipliers and the Hessian matrix can...

  9. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  10. Value-based management of design reuse

    Science.gov (United States)

    Carballo, Juan Antonio; Cohn, David L.; Belluomini, Wendy; Montoye, Robert K.

    2003-06-01

    Effective design reuse in electronic products has the potential to provide very large cost savings, substantial time-to-market reduction, and extra sources of revenue. Unfortunately, critical reuse opportunities are often missed because, although they provide clear value to the corporation, they may not benefit the business performance of an internal organization. It is therefore crucial to provide tools to help reuse partners participate in a reuse transaction when the transaction provides value to the corporation as a whole. Value-based Reuse Management (VRM) addresses this challenge by (a) ensuring that all parties can quickly assess the business performance impact of a reuse opportunity, and (b) encouraging high-value reuse opportunities by supplying value-based rewards to potential parties. In this paper we introduce the Value-Based Reuse Management approach and we describe key results on electronic designs that demonstrate its advantages. Our results indicate that Value-Based Reuse Management has the potential to significantly increase the success probability of high-value electronic design reuse.

  11. Designing Dexter-based cooperative hypermedia systems

    DEFF Research Database (Denmark)

    Grønbæk, Kaj; Madsen, Ole Lehrmann; Sloth, Lennard

    1993-01-01

    This paper discusses issues for the design of a Dexter-based cooperative hypermedia architecture and a specific system, DeVise Hypermedia (DHM), developed from this architecture. The Dexter Hypertext Reference Model [Hala90] was used as basis for designing the architecture. The Dexter model...... provides a general and solid foundation for designing a general hypermedia architecture. It introduces central concepts and proposes a layering of the architecture. However, to handle cooperative work aspects, such as sharing material and cooperative authoring, we have to go beyond the Dexter model...... concepts. To deal with such aspects we have extended our implementation of the Dexter concepts with support for long-term transactions, locking and event notification as called for by Halasz [Hala88]. The result is a platform independent architecture for developing cooperative hypermedia systems...

  12. An introduction to data base design

    CERN Document Server

    Salzberg, Betty Joan

    1986-01-01

    An Introduction to Data Base Design provides an understanding of how data base management systems (DBMS) work to be able to use any available commercial DBMS intelligently. This book presents the principle of independence of physical and local organization.Organized into seven chapters, this book begins with an overview of normal form theory. This text then describes the three types of DBMS. Other chapters consider the difficulties in processing queries where the names of the files are not mentioned. This book discusses as well how to group data hierarchically, how to use a preorder tree trave

  13. Computer Based Training Authors' and Designers' training

    Directory of Open Access Journals (Sweden)

    Frédéric GODET

    2016-03-01

    Full Text Available This communication, through couple of studies driven since 10 years, tries to show how important is the training of authors in Computer Based Training (CBT. We submit here an approach to prepare designers mastering Interactive Multimedia modules in this domain. Which institutions are really dedicating their efforts in training authors and designers in this area of CBTs? Television devices and broadcast organisations offered since year 60s' a first support for Distance Learning. New media, New Information and Communication Technologies (NICT allowed several public and private organisations to start Distance Learning projects. As usual some of them met their training objectives, other of them failed. Did their really failed? Currently, nobody has the right answer. Today, we do not have enough efficient tools allowing us to evaluate trainees' acquisition in a short term view. Training evaluation needs more than 10 to 20 years of elapsed time to bring reliable measures. Nevertheless, given the high investments already done in this area, we cannot wait until the final results of the pedagogical evaluation. A lot of analyses showed relevant issues which can be used as directions for CBTs authors and designers training. Warning - Our studies and the derived conclusions are mainly based on projects driven in the field. We additionally bring our several years experience in the training of movie film authors in the design of interactive multimedia products. Some of our examples are extracting from vocational training projects where we were involved in all development phases from the analysis of needs to the evaluation of the acquisition within the trainee's / employee job's. Obviously, we cannot bring and exhaustive approach in this domain where a lot of parameters are involved as frame for the CBT interactive multimedia modules authors' and designers' training.

  14. Evaluations of absorbed dose ratio factor of Al2O3 dosemeter in radiotherapy photon beams using cavity theory

    International Nuclear Information System (INIS)

    Zhu, J.; Chen, S.; Chen, L.; Liu, X.

    2012-01-01

    The aim of the work was to evaluate the absorbed dose ratio factor f md of an Al 2 O 3 dosemeter to water in photon radiotherapy beams using cavity theory. Burlin theory was used for calculating of this ratio. The effective mass attenuation coefficient β was obtained by comparing Monte Carlo simulations in monoenergetic photon beams. The evaluations of the absorbed dose ratio factor f md were studied for Al 2 O 3 dosemeters of different sizes, which were placed at various depths of the water phantom in different radiation field sizes of Mohan's 6, 10 and 15-MV X-rays. Beyond the build-up region, the variation of f md increases by 0.25 % as the depth increases from 4 to 10 cm. The maximum variation due to different dosemeter sizes is 8.3 %. The difference in the f md due to different radiation field sizes is 1.5 %. The effect of the dosemeter size cannot be neglected. The difference in the f md due to the radiation field sizes of different beams would increase as the dosemeter size increases. (authors)

  15. Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology.

    Science.gov (United States)

    Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T

    2015-04-01

    This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies 80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Tl response of LiF: Mg, Cu, P + PTFE (Mexico) and GR200A (China) dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Furetta, C.

    2003-01-01

    TLD-100 was the commercial dosemeter more known since some decades ago. This dosemeter was considered for many research groups as the reference material for developing new Tl materials for ionizing radiation dosimetry. Actually it seems that TLD-100 is going to be replaced by the Chinese material GR200A, as reference material due that this material in addition to be considered as a tissue equivalent material, is 30 to 35 times more sensitive that TLD- 100. Results of the study of the Tl response of LiF: Mg, Cu, P + Ptfe developed at ININ-Mexico, comparing them with those of GR200A are presented. These results showed that the sensitivity (s = Tl intensity/weight x dose) to gamma radiation of the LiF: Mg, Cu, P + Ptfe dosimeters was 4.34 meanwhile that of the commercial dosemeter was 3.41. Detection threshold of the dosemeters studied was 2.22 and 0.52 μGy respectively Repeatability after 10 cycles Irradiation-reading-annealing was ±1.39% and ±1.86% respectively. Both types of dosemeters presented a linear response as a function of gamma radiation in the range from 0.02 mGy and 100 Gy. (Author)

  17. PLD based design with VHDL RTL design, synthesis and implementation

    CERN Document Server

    Taraate, Vaibbhav

    2017-01-01

    This book covers basic fundamentals of logic design and advanced RTL design concepts using VHDL. The book is organized to describe both simple and complex RTL design scenarios using VHDL. It gives practical information on the issues in ASIC prototyping using FPGAs, design challenges and how to overcome practical issues and concerns. It describes how to write an efficient RTL code using VHDL and how to improve the design performance. The design guidelines by using VHDL are also explained with the practical examples in this book. The book also covers the ALTERA and XILINX FPGA architecture and the design flow for the PLDs. The contents of this book will be useful to students, researchers, and professionals working in hardware design and optimization. The book can also be used as a text for graduate and professional development courses.

  18. Design and Construction of Manned Lunar Base

    Science.gov (United States)

    Li, Zhijie

    2016-07-01

    Building manned lunar base is one of the core aims of human lunar exploration project, which is also an important way to carry out the exploitation and utilization of lunar in situ resources. The most important part of manned lunar base is the design and construction of living habitation and many factors should be considered including science objective and site selection. Through investigating and research, the scientific goals of manned lunar base should be status and characteristics ascertainment of lunar available in situ resources, then developing necessary scientific experiments and utilization of lunar in situ resources by using special environment conditions of lunar surface. The site selection strategy of manned lunar base should rely on scientific goals according to special lunar surface environment and engineering capacity constraints, meanwhile, consulting the landing sites of foreign unmanned and manned lunar exploration, and choosing different typical regions of lunar surface and analyzing the landform and physiognomy, reachability, thermal environment, sunlight condition, micro meteoroids protection and utilization of in situ resources, after these steps, a logical lunar living habitation site should be confirmed. This paper brings out and compares three kinds of configurations with fabricating processes of manned lunar base, including rigid module, flexible and construction module manned lunar base. 1.The rigid habitation module is usually made by metal materials. The design and fabrication may consult the experience of space station, hence with mature technique. Because this configuration cannot be folded or deployed, which not only afford limit working and living room for astronauts, but also needs repetitious cargo transit between earth and moon for lunar base extending. 2. The flexible module habitation can be folded in fairing while launching. When deploying on moon, the configuration can be inflatable or mechanically-deployed, which means under

  19. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study

    NARCIS (Netherlands)

    Koivisto, J.; Schulze, D.; Wolff, J.E.H.; Rottke, D.

    2014-01-01

    Objectives: The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Methods: Organ and effective

  20. Interior Design Based on Forough Farrokhzad Poetry

    Directory of Open Access Journals (Sweden)

    Mahsa Sanami

    2018-03-01

    Full Text Available The main purpose of this study is to correlate between art, literature, architect and visualization to translate the emotions and aspirations embodied in a well-known poet such as Forough Farrokhzad. Forough Farrokhzad widely regarded as a famous Iranian poet and an advocate for women’s liberation and independence. She wrote during a time when Iranian women were facing extensive discrimination and prejudice. Many of her works are rich in feminist related aspects of Iranian women. By visualization of Forough’s inner feelings, one can see a great revaluation in society towards women feelings and emotions. Like any other human, poets and artist both have thoughts and dreams rich in colors and words capsulizing their imaginary world in possible dreams which are all related to each person’s personality, culture, environment and etc. One of the ways to understand a poet is to understand the depth of his/her thoughts through his/her poems. Thus the main purpose of this research is to review interior design based on in depth analysis of related poems. Psychoanalysis of symbols, themes and colors used in poems, can be used to supplement words in extracting symptoms and energy depicting the poet inner feelings and imaginations when designing. The results of the discussing symbols and colors used by Forough in most of her poems, indicate her interest in life, death, love, society, intellectuality and philosophy. Finally the researchers through usage of visual effects and pictures used in her designs tries to assist the viewers to understand and feel the poet’s emotions and passions for life at the time of creating the poems. Thus, it can be assumed that the interior design is based on poetry rich in motion and dynamism.

  1. In silico fragment-based drug design.

    Science.gov (United States)

    Konteatis, Zenon D

    2010-11-01

    In silico fragment-based drug design (FBDD) is a relatively new approach inspired by the success of the biophysical fragment-based drug discovery field. Here, we review the progress made by this approach in the last decade and showcase how it complements and expands the capabilities of biophysical FBDD and structure-based drug design to generate diverse, efficient drug candidates. Advancements in several areas of research that have enabled the development of in silico FBDD and some applications in drug discovery projects are reviewed. The reader is introduced to various computational methods that are used for in silico FBDD, the fragment library composition for this technique, special applications used to identify binding sites on the surface of proteins and how to assess the druggability of these sites. In addition, the reader will gain insight into the proper application of this approach from examples of successful programs. In silico FBDD captures a much larger chemical space than high-throughput screening and biophysical FBDD increasing the probability of developing more diverse, patentable and efficient molecules that can become oral drugs. The application of in silico FBDD holds great promise for historically challenging targets such as protein-protein interactions. Future advances in force fields, scoring functions and automated methods for determining synthetic accessibility will all aid in delivering more successes with in silico FBDD.

  2. Photon and fast neutron dosimetry using aluminium oxide thermoluminescence dosemeters in a pool-type research reactor

    International Nuclear Information System (INIS)

    Santos, J.P.; Marques, J.G.; Fernandes, A.C.; Osvay, M.

    2007-01-01

    Al 2 O 3 :Mg,Y thermoluminescence (TL) dosemeters were used to measure photon and fast neutron doses in the mixed radiation field of the Portuguese Research Reactor. The dosemeters were irradiated in core positions under a photon dose rate of the order of 10 4 Gy/h and a fast neutron flux in the range of 10 9 -10 11 n/cm 2 /s. In order to evaluate the ability of the TL dosemeters for mixed field dosimetry at the research reactor, the measurements were compared with results obtained via conventional methods. The agreement between the different methods is better than 13% for the determination of photon doses and within 5% for the determination of neutron fluxes in mixed fields

  3. Characteristics and performance of the Sunna high dose dosemeter using green photoluminescence and UV absorption readout methods

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.D.; Murphy, M.K.; Tinker, M.R.; Kovacs, A.; McLaughlin, W

    2002-07-01

    Growth in the use of ionising radiation for medical sterilisation and the potential for wide-scale international food irradiation have created the need for robust, mass-producible, inexpensive, and highly accurate radiation dosemeters. The Sunna dosemeter, lithium fluoride injection-moulded in a polyethylene matrix, can be read out using either green photoluminescence or ultraviolet (UV) absorption. The Sunna dosemeter can be mass-produced inexpensively with high precision. Both the photoluminescent and the UV absorption reader are simple and inexpensive. Both methods of analysis display negligible humidity effects, minimal dose rate dependence, acceptable post-irradiation effects, and permit measurements with a precision of nearly 1% 1s. The UV method shows negligible irradiation temperature effects from -30 deg. C to +60 deg. C. The photoluminescence method shows negligible irradiation temperature effects above room temperature for sterilisation dose levels and above. The dosimetry characteristics of these two readout methods are presented along with performance data in commercial sterilisation facilities. (author)

  4. Influence of the PMMA and the ISO slab phantom for calibrating personal dosemeters

    International Nuclear Information System (INIS)

    Ginjaume, M.; Ortega, X.; Barbosa, A.

    2000-01-01

    Wide agreement has been achieved among the main Bodies and Organisations involved in standardisation of radiation protection, related to the operational quantities for personal dosimetry. Since their definition in 1985, several reports have been published to clarify and define the experimental set up to be used for the calibration of dosemeters in terms of the above-mentioned quantities. Among these lines, ICRU 47 has listed five different phantoms that are used for calibration and whose results were accurate, within accepted uncertainties. However, to achieve uniformity in calibration procedures, the 30 cm x 30 cm x 15 cm PMMA slab phantom was recommended. The secondary calibration Laboratory from the Institut de Techniques Energetiques at the Technical University of Catalonia (UPC) agreed with the Spanish Nacional Laboratory to adopt the recommended PMMA phantom but to improve the accuracy of the calibration procedure, by introducing a correction factor for backscatter differences in a PMMA and an ICRU slab phantom. Such corrections were of the order of 8% for the low-energy X-ray qualities. Recently, ISO in ISO 4037-3, has proposed the ISO water slab phantom which consists of a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (front wall 2.5 mm thick). This new phantom could be substituted by the above mentioned PMMA phantom for radiation qualities with mean energy equal or above that of 137 Cs. The aim of this work is to compare the influence of both phantoms when calibrating personal dosemeters with photons. A set of four TL personal dosemeters that are used in the UPC personal dosimetry Service and an electronic personal dosemeter (SIEMENS EPD-2) were calibrated in terms of H p (10) and H p (0.07) using the two proposed phantoms. Calibration factors for ISO X-ray narrow spectra, 137 Cs and 60 Co were experimentally obtained for each phantom and compared. In the TL measurements, differences were found to be within TL statistical uncertainty, provided that a

  5. NEIGHBORHOOD TEST DESIGN BASED ON HISTORIC PRECEDENTS

    Directory of Open Access Journals (Sweden)

    Besim S. Hakim

    2012-07-01

    Full Text Available There have been various attempts to emulate traditional architecture and to experiment with the form and aesthetics of building design. However, learning from precedents of urban morphology is rare. This design study is a test at the neighborhood level using the pattern of traditional courtyard housing that is prevalent in the majority of historic towns and cities of North Africa and the Middle East. The study is undertaken at five levels of design enquiry: dwelling types, dwelling groups, neighborhood segment and community center. All of which are synthesized into a full prototype neighborhood comprising of 428 dwelling units covering an area that includes circulation and the community center, of 17.6 hectares. The test demonstrates that the traditional pattern of neighborhoods that are based on the typology of the courtyard dwelling as the initial generator of urban form may be used to develop a contemporary settlement pattern that is compatible with current necessities of lifestyle, vehicular circulation,  including parking and infrastructure achieving an attractive livable environment with an overall gross density, that includes a community center, of about 24 dwelling units per hectare.

  6. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  7. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of Hp(3) monitoring. A 2015 review

    International Nuclear Information System (INIS)

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O’Connor, Una

    2015-01-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended. (review)

  8. Sequential ensemble-based optimal design for parameter estimation: SEQUENTIAL ENSEMBLE-BASED OPTIMAL DESIGN

    Energy Technology Data Exchange (ETDEWEB)

    Man, Jun [Zhejiang Provincial Key Laboratory of Agricultural Resources and Environment, Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou China; Zhang, Jiangjiang [Zhejiang Provincial Key Laboratory of Agricultural Resources and Environment, Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou China; Li, Weixuan [Pacific Northwest National Laboratory, Richland Washington USA; Zeng, Lingzao [Zhejiang Provincial Key Laboratory of Agricultural Resources and Environment, Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou China; Wu, Laosheng [Department of Environmental Sciences, University of California, Riverside California USA

    2016-10-01

    The ensemble Kalman filter (EnKF) has been widely used in parameter estimation for hydrological models. The focus of most previous studies was to develop more efficient analysis (estimation) algorithms. On the other hand, it is intuitively understandable that a well-designed sampling (data-collection) strategy should provide more informative measurements and subsequently improve the parameter estimation. In this work, a Sequential Ensemble-based Optimal Design (SEOD) method, coupled with EnKF, information theory and sequential optimal design, is proposed to improve the performance of parameter estimation. Based on the first-order and second-order statistics, different information metrics including the Shannon entropy difference (SD), degrees of freedom for signal (DFS) and relative entropy (RE) are used to design the optimal sampling strategy, respectively. The effectiveness of the proposed method is illustrated by synthetic one-dimensional and two-dimensional unsaturated flow case studies. It is shown that the designed sampling strategies can provide more accurate parameter estimation and state prediction compared with conventional sampling strategies. Optimal sampling designs based on various information metrics perform similarly in our cases. The effect of ensemble size on the optimal design is also investigated. Overall, larger ensemble size improves the parameter estimation and convergence of optimal sampling strategy. Although the proposed method is applied to unsaturated flow problems in this study, it can be equally applied in any other hydrological problems.

  9. Design of nanostructured-based glucose biosensors

    Science.gov (United States)

    Komirisetty, Archana; Williams, Frances; Pradhan, Aswini; Konda, Rajini B.; Dondapati, Hareesh; Samantaray, Diptirani

    2012-04-01

    This paper presents the design of glucose sensors that will be integrated with advanced nano-materials, bio-coatings and electronics to create novel devices that are highly sensitive, inexpensive, accurate, and reliable. In the work presented, a glucose biosensor and its fabrication process flow have been designed. The device is based on electrochemical sensing using a working electrode with bio-functionalized zinc oxide (ZnO) nano-rods. Among all metal oxide nanostructures, ZnO nano-materials play a significant role as a sensing element in biosensors due to their properties such as high isoelectric point (IEP), fast electron transfer, non-toxicity, biocompatibility, and chemical stability which are very crucial parameters to achieve high sensitivity. Amperometric enzyme electrodes based on glucose oxidase (GOx) are used due to their stability and high selectivity to glucose. The device also consists of silicon dioxide and titanium layers as well as platinum working and counter electrodes and a silver/silver chloride reference electrode. Currently, the biosensors are being fabricated using the process flow developed. Once completed, the sensors will be bio-functionalized and tested to characterize their performance, including their sensitivity and stability.

  10. Advanced overlay analysis through design based metrology

    Science.gov (United States)

    Ji, Sunkeun; Yoo, Gyun; Jo, Gyoyeon; Kang, Hyunwoo; Park, Minwoo; Kim, Jungchan; Park, Chanha; Yang, Hyunjo; Yim, Donggyu; Maruyama, Kotaro; Park, Byungjun; Yamamoto, Masahiro

    2015-03-01

    As design rule shrink, overlay has been critical factor for semiconductor manufacturing. However, the overlay error which is determined by a conventional measurement with an overlay mark based on IBO and DBO often does not represent the physical placement error in the cell area. The mismatch may arise from the size or pitch difference between the overlay mark and the cell pattern. Pattern distortion caused by etching or CMP also can be a source of the mismatch. In 2014, we have demonstrated that method of overlay measurement in the cell area by using DBM (Design Based Metrology) tool has more accurate overlay value than conventional method by using an overlay mark. We have verified the reproducibility by measuring repeatable patterns in the cell area, and also demonstrated the reliability by comparing with CD-SEM data. We have focused overlay mismatching between overlay mark and cell area until now, further more we have concerned with the cell area having different pattern density and etch loading. There appears a phenomenon which has different overlay values on the cells with diverse patterning environment. In this paper, the overlay error was investigated from cell edge to center. For this experiment, we have verified several critical layers in DRAM by using improved(Better resolution and speed) DBM tool, NGR3520.

  11. Prioritization of design changes based on PSA

    International Nuclear Information System (INIS)

    Krajnc, B.; Mavko, B.

    1996-01-01

    Effective use of Probabilistic Safety Analyses (PSA) in the day to day plant operation is subject of intensive discussions among plant operators and regulators. There are several possible applications in which the PSA can be used, among those also to use the PSA approach for the quantification of influence of different proposed design changes to nuclear safety - influence on public safety - health. NPP Krsko is one of those plants that successfully completed its PSA project, with Level 1 and Level 2 analyses and effective know-how transfer. It also faces a number of regulatory and internally generated requirements for different design changes, mainly due to the fact that the plant is committed to continuous augmentation of nuclear safety. It is considered that the available tools and knowledge should be used and therefore applicable methodology should be developed for effective prioritization of proposed design changes by performing cost-benefit analyses for all major modifications - focusing on their influence on nuclear safety. Based on the above a new method for prioritization of design changes is proposed. The method uses Level 1 results (in the sense of plant damage states and their frequencies) directly as an input for further processing - first decision step to decide whether the proposed modification has or has no influence on nuclear safety. In Level 2 analyses the combination of probabilistic and deterministic approach was adopted. In fact the results of the deterministic analyses of severe accidents are treated in probabilistic manner due to large uncertainty of results. Finally to be able to perform plant specific cost benefit analyses so called partial Level 3 was defined. The proposed methods was preliminary tested and it gave favorable results. (author)

  12. A new lease of life for the Farmer-Baldwin dosemeter

    International Nuclear Information System (INIS)

    Vojnovic, B.

    1984-01-01

    Replacement batteries for the widely used 'Farmer-Baldwin Sub-standard x-ray Dosemeter' (Farmer 1955), manufactured by Baldwin Industrial Controls, of Dartford, Kent, have become expensive and difficult to obtain, resulting in a number of such units being unnecessarily taken out of service. This note describes how the relatively simple addition of a DC-DC inverter can drastically reduce the maintenance costs of the instrument (MK2 version) by powering it from three commonly available 1.5 V cells, type U2 (IEC type R20). The function of the various controls on the instrument is not affected in any way. (author)

  13. Results of the European Community's beta intercomparison programme of individual dosemeters in 1986

    International Nuclear Information System (INIS)

    Bigard, T.; Sequin, H.; Chartier, J.L.; Christensen, P.; Francis, T.M.; Lembo, L.

    1988-01-01

    For over 20 years, the Commission of the European Communities, in collaboration with competent laboratories in the member states, has been conducting intercomparisons of individual dosemeters with the objective of improving technique for monitoring ionizing radiation and establishing a common basis for dose assessment within the Community. These programmes not only serve the participants with an opportunity to validate their calibration and measuring procedures but also help to create a forum in which to exchange information and discuss experience with other participants. The performance and results of such an intercomparison exercise conducted in 1986 are reported here

  14. Al2 O3:Cr,Ni: a possible thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Mariani R, Francisco; Roman B, Alvaro; Saavedra S, Renato; Ibarra S, Angel

    1996-01-01

    Results from a study on the thermoluminescent (Tl) emission from Al 2 O 3 :Cr,Ni are presented. The measurements were obtained for evaluation of the Al 2 O 3 :Cr,Ni dosimetric properties. Different crystal batches were exposed to two kind of ionizing radiation (X-ray and β - ). The Tl spectrum has a main peak with high thermal and optical stability, deviating from linearity for doses lower than 3.6 Gy. Furthermore, this material shows advantages (thermal resistance, reusability, multiple heating cycles) compared to TLD-100. Measured Al 2 O 3 :Cr,Ni properties indicate that it could be used as a dosemeter. (author)

  15. Standard X ray beams for calibration of dosemeters used in radiation protection practice

    International Nuclear Information System (INIS)

    Pernicka, F.; Michalik, V.

    1992-01-01

    Kerma in air is a widely used reference quantity specified by different calibration laboratories. Calibration of dosemeters used for individual and environmental monitoring requires a knowledge of conversion coefficients between the air kerma and an appropriate protection quantity. These were determined for sets of standard X ray beams using measured spectral distributions, calculated mean energies and effective energies obtained from HVLs measured by an ionisation chamber. There is a good agreement among these three approaches for energies down to 60-70 keV. For lower energies one can expect differences up to 10% if the coefficients are determined from the mean or effective energy instead from the spectral distribution. (author)

  16. Dose evaluation in criticality accidents using response of panasonic TL personal dosemeters (UD-809/UD-802)

    International Nuclear Information System (INIS)

    Zeyrek, C. T.; Guenduez, H.

    2012-01-01

    This study gives the results of dosimetry measurements carried out in the Silene reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silene experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together. (authors)

  17. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    Science.gov (United States)

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.

  18. Study of some characteristic dosimetric of the LIF:Mg, You (JR1152C) for their employment as environmental dosemeter

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Prendes Alonso, M.

    1998-01-01

    As the interest grows in knowing the effects on the health of the drops dose of natural or artificial radiation, it is made but necessary a system dosimetric able to measure those dose levels accurately. P but of twenty years the dosemeters thermoluminescent (TL) they have constituted a simple and beautiful method for such mensurations. In the work the rehearsals of homogeneity, reproducibility, line lay, detection threshold, auto irradiation, residual, fading and angular dependence are described. The results demonstrate that the dosemeter satisfies the main requirements to be an employee in the environmental monitoring

  19. Validation of response simulation methodology of Albedo dosemeter; Validacao da metodologia de simulacao de resposta de dosimetro de Albedo

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, B.M.; Silva, A.X. da, E-mail: bfreitas@nuclear.ufrj.br [Coordenacao do Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Mauricio, C.L.P. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    The Instituto de Radioprotecao e Dosimetria developed and runs a neutron TLD albedo individual monitoring service. To optimize the dose calculation algorithm and to infer new calibration factors, the response of this dosemeter was simulated. In order to validate this employed methodology, it was applied in the simulation of the problem of the QUADOS (Quality Assurance of Computational Tools for Dosimetry) intercomparison, aimed to evaluate dosimetric problems, one being to calculate the response of a generic albedo dosemeter. The obtained results were compared with those of other modeling and the reference one, with good agreements. (author)

  20. Radiation dosemeters and ambient dose rate measuring systems

    International Nuclear Information System (INIS)

    Maushart, R.

    1985-01-01

    The manufacturers have got the feeling that the PTB only reluctantly accepts complex dosimetric systems or systems with modern digital and microprocessor technology. Especially the fact that the PTB demands a restriction to a defined system configuration which must not be changed after design approval is felt to be a severe handicap. The rigid frame of design qualification forces manufacturers to adopt a two-tier development line, at least for ambient dose rate measuring systems, and frequently it is not necessarily the 'nature' system, i.e. equipment with modern technology, that is sent in to the PTB for testing. The way of solving the problem could be that PTB more readily accepts less familiar technologies, for instance by more frequently approving equipment at least preliminarily or for a restricted period of time, in order to collect experience. Another way could be to grant licence for system components, especially detectors. (orig./HP) [de

  1. Constructivism Based Learning: Design and Practice

    Directory of Open Access Journals (Sweden)

    Lia Kurniawati

    2016-06-01

    Full Text Available Abstract One of many problems in the madrasahs is that learning processes less-involve students actively (teacher-centered, thus, it affects to the improvement of learning outcomes and quality of the graduates. The purposes of this study are , firstly, to analyze what type of constructivism learning models, which can be developed to overcome madrasahs’ problems. Secondly, how to design and implement a learning plan based on the developed constructivism models. This research was conducted at Private Islamic Elementary School  (Madrasah Ad-Diyanah Ciputat, South Tangerang. Research method used in this study is descriptive-qualitative research. The results showed that the active learning models based on constructivism are suitable to be developed in the Madarasah, which were the models of Problem Based Learning (PBM, Realistic Learning, Inquiry Learning and Thematic Learning and also how the development of the learning processes from the lesson plans to the learning implementation showed a paradigm shifting from teacher-centered to student-centered. Abstrak Salah satu permasalahan di madrasah-madrasah adalah proses pembelajaran yang kurang melibatkan siswa secara aktif (berpusat pada guru, sehingga hal ini mengakibatkan pada peningkatan hasil belajar dan kualitas lulusan. Tujuan dari penelitian ini adalah, pertama, untuk menganalisis jenis model pembelajaran konstruktivisme apa yang dapat dikembangkan untuk mengatasi permasalahan di madrasah. Ke dua, bagaimana merancang dan melaksanakan rencana pembelajaran berdasarkan model konstruktivisme yang dikembangkan. Penelitian ini dilaksanakan di Sekolah Dasar Swasta (madrasah Ad-Diayanah Ciputat, Tangerang Selatan. Metode penelitian yang digunakan adalah metode deskriptif-kualitatif. Hasil penelitian menunjukkan bahwa model pembelajaran aktif yang berbasis konstruktivisme sesuai untuk dikembangkan di madrasah, yakni model pembelajaran Problem Based Learning (PBL, Pembelajaran Realistis, Pembelajaran

  2. A review of two methods used in the USA to assess HE during fluoroscopic-based radiology

    International Nuclear Information System (INIS)

    Craig Yoder, R.; Salasky, Mark R.

    2016-01-01

    Dosemeter results for ∼81 500 people performing fluoroscopic and interventional radiology procedures were examined to identify differences between groups monitored either by using two dosemeters, one placed at the collar above the apron and a second placed under the apron on the torso (EDE1) or by using one single dosemeter placed at the collar above the apron (EDE2). The median annual HE was 0.17 mSv for those monitored using the EDE1 protocol and 0.26 mSv for the group using the EDE2 protocol. The EDE2 method was used most frequently with the EDE1 method preferred for those more highly exposed. Approximately, 22 % of dosemeter results for EDE1 were inconsistent with expected norms based on over and under apron dosemeter relationships. (authors)

  3. SNAD: sequence name annotation-based designer

    Directory of Open Access Journals (Sweden)

    Gorbalenya Alexander E

    2009-08-01

    Full Text Available Abstract Background A growing diversity of biological data is tagged with unique identifiers (UIDs associated with polynucleotides and proteins to ensure efficient computer-mediated data storage, maintenance, and processing. These identifiers, which are not informative for most people, are often substituted by biologically meaningful names in various presentations to facilitate utilization and dissemination of sequence-based knowledge. This substitution is commonly done manually that may be a tedious exercise prone to mistakes and omissions. Results Here we introduce SNAD (Sequence Name Annotation-based Designer that mediates automatic conversion of sequence UIDs (associated with multiple alignment or phylogenetic tree, or supplied as plain text list into biologically meaningful names and acronyms. This conversion is directed by precompiled or user-defined templates that exploit wealth of annotation available in cognate entries of external databases. Using examples, we demonstrate how this tool can be used to generate names for practical purposes, particularly in virology. Conclusion A tool for controllable annotation-based conversion of sequence UIDs into biologically meaningful names and acronyms has been developed and placed into service, fostering links between quality of sequence annotation, and efficiency of communication and knowledge dissemination among researchers.

  4. Designing a Constraint Based Parser for Sanskrit

    Science.gov (United States)

    Kulkarni, Amba; Pokar, Sheetal; Shukl, Devanand

    Verbal understanding (śā bdabodha) of any utterance requires the knowledge of how words in that utterance are related to each other. Such knowledge is usually available in the form of cognition of grammatical relations. Generative grammars describe how a language codes these relations. Thus the knowledge of what information various grammatical relations convey is available from the generation point of view and not the analysis point of view. In order to develop a parser based on any grammar one should then know precisely the semantic content of the grammatical relations expressed in a language string, the clues for extracting these relations and finally whether these relations are expressed explicitly or implicitly. Based on the design principles that emerge from this knowledge, we model the parser as finding a directed Tree, given a graph with nodes representing the words and edges representing the possible relations between them. Further, we also use the Mīmā ṃsā constraint of ākā ṅkṣā (expectancy) to rule out non-solutions and sannidhi (proximity) to prioritize the solutions. We have implemented a parser based on these principles and its performance was found to be satisfactory giving us a confidence to extend its functionality to handle the complex sentences.

  5. Developments in holographic-based scanner designs

    Science.gov (United States)

    Rowe, David M.

    1997-07-01

    Holographic-based scanning systems have been used for years in the high resolution prepress markets where monochromatic lasers are generally utilized. However, until recently, due to the dispersive properties of holographic optical elements (HOEs), along with the high cost associated with recording 'master' HOEs, holographic scanners have not been able to penetrate major scanning markets such as the laser printer and digital copier markets, low to mid-range imagesetter markets, and the non-contact inspection scanner market. Each of these markets has developed cost effective laser diode based solutions using conventional scanning approaches such as polygon/f-theta lens combinations. In order to penetrate these markets, holographic-based systems must exhibit low cost and immunity to wavelength shifts associated with laser diodes. This paper describes recent developments in the design of holographic scanners in which multiple HOEs, each possessing optical power, are used in conjunction with one curved mirror to passively correct focal plane position errors and spot size changes caused by the wavelength instability of laser diodes. This paper also describes recent advancements in low cost production of high quality HOEs and curved mirrors. Together these developments allow holographic scanners to be economically competitive alternatives to conventional devices in every segment of the laser scanning industry.

  6. GA BASED GLOBAL OPTIMAL DESIGN PARAMETERS FOR ...

    African Journals Online (AJOL)

    Journal of Modeling, Design and Management of Engineering Systems ... DESIGN PARAMETERS FOR CONSECUTIVE REACTIONS IN SERIALLY CONNECTED ... for the process equipments such as chemical reactors used in industries.

  7. AUTOMATION DESIGN FOR MONORAIL - BASED SYSTEM PROCESSES

    Directory of Open Access Journals (Sweden)

    Bunda BESA

    2016-12-01

    Full Text Available Currently, conventional methods of decline development put enormous cost pressure on the profitability of mining operations. This is the case with narrow vein ore bodies where current methods and mine design of decline development may be too expensive to support economic extraction of the ore. According to studies, the time it takes to drill, clean and blast an end in conventional decline development can be up to 224 minutes. This is because once an end is blasted, cleaning should first be completed before drilling can commence, resulting in low advance rates per shift. Improvements in advance rates during decline development can be achieved by application of the Electric Monorail Transport System (EMTS based drilling system. The system consists of the drilling and loading components that use monorail technology to drill and clean the face during decline development. The two systems work simultaneously at the face in such a way that as the top part of the face is being drilled the pneumatic loading system cleans the face. However, to improve the efficiency of the two systems, critical processes performed by the two systems during mining operations must be automated. Automation increases safety and productivity, reduces operator fatigue and also reduces the labour costs of the system. The aim of this paper is, therefore, to describe automation designs of the two processes performed by the monorail drilling and loading systems during operations. During automation design, critical processes performed by the two systems and control requirements necessary to allow the two systems execute such processes automatically have also been identified.

  8. Designing solar thermal experiments based on simulation

    International Nuclear Information System (INIS)

    Huleihil, Mahmoud; Mazor, Gedalya

    2013-01-01

    In this study three different models to describe the temperature distribution inside a cylindrical solid body subjected to high solar irradiation were examined, beginning with the simpler approach, which is the single dimension lump system (time), progressing through the two-dimensional distributed system approach (time and vertical direction), and ending with the three-dimensional distributed system approach with azimuthally symmetry (time, vertical direction, and radial direction). The three models were introduced and solved analytically and numerically. The importance of the models and their solution was addressed. The simulations based on them might be considered as a powerful tool in designing experiments, as they make it possible to estimate the different effects of the parameters involved in these models

  9. Knowledge base rule partitioning design for CLIPS

    Science.gov (United States)

    Mainardi, Joseph D.; Szatkowski, G. P.

    1990-01-01

    This describes a knowledge base (KB) partitioning approach to solve the problem of real-time performance using the CLIPS AI shell when containing large numbers of rules and facts. This work is funded under the joint USAF/NASA Advanced Launch System (ALS) Program as applied research in expert systems to perform vehicle checkout for real-time controller and diagnostic monitoring tasks. The Expert System advanced development project (ADP-2302) main objective is to provide robust systems responding to new data frames of 0.1 to 1.0 second intervals. The intelligent system control must be performed within the specified real-time window, in order to meet the demands of the given application. Partitioning the KB reduces the complexity of the inferencing Rete net at any given time. This reduced complexity improves performance but without undo impacts during load and unload cycles. The second objective is to produce highly reliable intelligent systems. This requires simple and automated approaches to the KB verification & validation task. Partitioning the KB reduces rule interaction complexity overall. Reduced interaction simplifies the V&V testing necessary by focusing attention only on individual areas of interest. Many systems require a robustness that involves a large number of rules, most of which are mutually exclusive under different phases or conditions. The ideal solution is to control the knowledge base by loading rules that directly apply for that condition, while stripping out all rules and facts that are not used during that cycle. The practical approach is to cluster rules and facts into associated 'blocks'. A simple approach has been designed to control the addition and deletion of 'blocks' of rules and facts, while allowing real-time operations to run freely. Timing tests for real-time performance for specific machines under R/T operating systems have not been completed but are planned as part of the analysis process to validate the design.

  10. Preference-Based Design in Architecture

    NARCIS (Netherlands)

    Binnekamp, R.

    2010-01-01

    Architectural design is a complex process as a result of two prominent characteristics of choice making: 1) multiple designs can fit into one intended purpose, which raises the question: how to choose the design that fits best, and 2) a multitude of decision makers have an interest in the design

  11. CFD based draft tube hydraulic design optimization

    International Nuclear Information System (INIS)

    McNabb, J; Murry, N; Mullins, B F; Devals, C; Kyriacou, S A

    2014-01-01

    The draft tube design of a hydraulic turbine, particularly in low to medium head applications, plays an important role in determining the efficiency and power characteristics of the overall machine, since an important proportion of the available energy, being in kinetic form leaving the runner, needs to be recovered by the draft tube into static head. For large units, these efficiency and power characteristics can equate to large sums of money when considering the anticipated selling price of the energy produced over the machine's life-cycle. This same draft tube design is also a key factor in determining the overall civil costs of the powerhouse, primarily in excavation and concreting, which can amount to similar orders of magnitude as the price of the energy produced. Therefore, there is a need to find the optimum compromise between these two conflicting requirements. In this paper, an elaborate approach is described for dealing with this optimization problem. First, the draft tube's detailed geometry is defined as a function of a comprehensive set of design parameters (about 20 of which a subset is allowed to vary during the optimization process) and are then used in a non-uniform rational B-spline based geometric modeller to fully define the wetted surfaces geometry. Since the performance of the draft tube is largely governed by 3D viscous effects, such as boundary layer separation from the walls and swirling flow characteristics, which in turn governs the portion of the available kinetic energy which will be converted into pressure, a full 3D meshing and Navier-Stokes analysis is performed for each design. What makes this even more challenging is the fact that the inlet velocity distribution to the draft tube is governed by the runner at each of the various operating conditions that are of interest for the exploitation of the powerhouse. In order to determine these inlet conditions, a combined steady-state runner and an initial draft tube analysis

  12. CFD based draft tube hydraulic design optimization

    Science.gov (United States)

    McNabb, J.; Devals, C.; Kyriacou, S. A.; Murry, N.; Mullins, B. F.

    2014-03-01

    The draft tube design of a hydraulic turbine, particularly in low to medium head applications, plays an important role in determining the efficiency and power characteristics of the overall machine, since an important proportion of the available energy, being in kinetic form leaving the runner, needs to be recovered by the draft tube into static head. For large units, these efficiency and power characteristics can equate to large sums of money when considering the anticipated selling price of the energy produced over the machine's life-cycle. This same draft tube design is also a key factor in determining the overall civil costs of the powerhouse, primarily in excavation and concreting, which can amount to similar orders of magnitude as the price of the energy produced. Therefore, there is a need to find the optimum compromise between these two conflicting requirements. In this paper, an elaborate approach is described for dealing with this optimization problem. First, the draft tube's detailed geometry is defined as a function of a comprehensive set of design parameters (about 20 of which a subset is allowed to vary during the optimization process) and are then used in a non-uniform rational B-spline based geometric modeller to fully define the wetted surfaces geometry. Since the performance of the draft tube is largely governed by 3D viscous effects, such as boundary layer separation from the walls and swirling flow characteristics, which in turn governs the portion of the available kinetic energy which will be converted into pressure, a full 3D meshing and Navier-Stokes analysis is performed for each design. What makes this even more challenging is the fact that the inlet velocity distribution to the draft tube is governed by the runner at each of the various operating conditions that are of interest for the exploitation of the powerhouse. In order to determine these inlet conditions, a combined steady-state runner and an initial draft tube analysis, using a

  13. Chip Design Process Optimization Based on Design Quality Assessment

    Science.gov (United States)

    Häusler, Stefan; Blaschke, Jana; Sebeke, Christian; Rosenstiel, Wolfgang; Hahn, Axel

    2010-06-01

    Nowadays, the managing of product development projects is increasingly challenging. Especially the IC design of ASICs with both analog and digital components (mixed-signal design) is becoming more and more complex, while the time-to-market window narrows at the same time. Still, high quality standards must be fulfilled. Projects and their status are becoming less transparent due to this complexity. This makes the planning and execution of projects rather difficult. Therefore, there is a need for efficient project control. A main challenge is the objective evaluation of the current development status. Are all requirements successfully verified? Are all intermediate goals achieved? Companies often develop special solutions that are not reusable in other projects. This makes the quality measurement process itself less efficient and produces too much overhead. The method proposed in this paper is a contribution to solve these issues. It is applied at a German design house for analog mixed-signal IC design. This paper presents the results of a case study and introduces an optimized project scheduling on the basis of quality assessment results.

  14. Three-dimensional absorbed dose determinations by N.M.R. analysis of phantom-dosemeters

    International Nuclear Information System (INIS)

    Gambarini, G.; Birattari, C.; Fumagalli, M.L.; Vai, A.; Monti, D.; Salvadori, P.; Facchielli, L.; Sichirollo, A.E.

    1996-01-01

    Magnetic resonance imaging of a tissue-equivalent phantom is a promising technique for three-dimensional determination of absorbed dose from ionizing radiation. A reliable method of determining the spatial distribution of absorbed dose is indispensable for the planning of treatment in the presently developed radiotherapy techniques aimed at obtaining high energy selectively delivered to cancerous tissues, with low dose delivered to the surrounding healthy tissue. Aqueous gels infused with the Fricke dosemeter (i.e. with a ferrous sulphate solution), as proposed in 1984 by Gore et al., have shown interesting characteristics and, in spite of some drawbacks that cause a few limitations to their utilisation, they have shown the feasibility of three-dimensional dose determinations by nuclear magnetic resonance (NMR) imaging. Fricke-infused agarose gels with various compositions have been analysed, considering the requirements of the new radiotherapy techniques, in particular Boron Neutron Capture Therapy (B.N.C.T.) and proton therapy. Special attention was paid to obtain good tissue equivalence for every radiation type of interest. In particular, the tissue equivalence for thermal neutrons, which is a not simple problem, has also been satisfactorily attained. The responses of gel-dosemeters having the various chosen compositions have been analysed, by mean of NMR instrumentation. Spectrophotometric measurements have also been performed, to verify the consistence of the results. (author)

  15. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence

    International Nuclear Information System (INIS)

    Beerten, K.; Vanhavere, F.

    2010-01-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to 60 Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity. (authors)

  16. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence.

    Science.gov (United States)

    Beerten, Koen; Vanhavere, Filip

    2010-08-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.

  17. State of the art in thermoluminescent dosimetry using dosemeters with automated read-out

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1979-01-01

    In the beginning, the results obtained with automated read-out TLD have been quite disappointing, both for manufacturers and users. In response to this, industry then seeked advice and assistance from those experienced in the practical use of dosemeters, and the development of the second generation of automated TLD has been a common task of manufacturers and purchosers. As a preliminary achievement of development work along this line, a dosemeter has been presented by a Japanese manufacturer, meeting the requirements in quite a satisfactory way. The device is characterized by a frequency of disturbance of -5 , a microprocessor for controlling the measuring and control functions, possibility of active input of device parameters and boundary conditions, extensive self-control of operating functions, complete data protection, and thin-film detector technique. Pursuing this line of development, and taking into account future recommentations, automated thermoluminescent dosimetry does seem to be a promising alternative to current measuring techniques in personnel monitoring. (orig./RW) [de

  18. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  19. Correction factors for clinical dosemeters used in large field dosimetry

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.

    1989-08-01

    The determination of the absorbed dose in high-energy photon and electron beams by the user is carried out as a two-step procedure. First the ionization chamber is calibrated at a reference quality by the user at a standard laboratory, and then the chamber is used to determine the absorbed dose with the user's beam. A number of conversion and correction factors have to be applied. Different sets of factors are needed depending on the physical quantity the calibration refers to, the calibration geometry and the chamber design. Another correction factor to be introduced for the absorbed dose determination in large fields refers to radiation effects on the stem, cable and sometimes connectors. A simple method was developed to be suggested to hospital physicists to be followed during large radiation field dosimetry, in order to evaluate the radiation effects of cables and connectors and to determine correction factors for each system or geometry. (author) [pt

  20. Characterization of workplaces in interventional radiology using active dosemeters ALARA OD

    International Nuclear Information System (INIS)

    Prlic, I.; Milkovic-Kraus, S.; Mestrovic, T.; Suric-Mihic, M.; Vrtar, M.

    2005-01-01

    Full text: Because of progressive development and extended use of interventional radiology procedures it is highly recommended that all individuals involved in the process should be aware of the potential for both stochastic and deterministic effects due to occupational exposure. Interventional radiology procedures are essentially therapeutic and are performed by various medical specialists, not only by properly educated radiologists. As the procedures are performed in such a manner that certain number of medical staff are always needed near the patient, near the x- ray unit, ensuring 'safe' working environment in such radiation x-ray field geometry is a new challenge to regular radiation protection. In this work we are not primary concerned in relatively high doses delivered to patients undergoing interventional procedures. The patient is rather regarded as a secondary radiation source which emits scattered x-rays. The working staff, moving in mixed, primary and scattered x-ray field, is expected to be exposed to higher occupational doses due to combination of extended fluoroscopy times, elevated fluoroscopy currents and larger amount of radiographic images required. The protection of both patients and staff is to be upgraded. As passive dosemetes will give us clear knowledge only about the monthly integrated occupational dose, a reasonable doubt exists about the frequency and duration, of receiving the dose. Measuring dose rate is not a part of regular passive dosemeters monitoring systems. This is why we have developed active - electronic dosemeter device which provides us with additional dosimetry data about the frequency and duration of professional exposure burden. Digital dosemeter ALARA OD will record and integrate any occupational dose including the normal radiation background in the working area. It will record the time and duration of any fluoroscopic exposure done. This gives us the data about the dose rate of occupational radiation and frequency of

  1. Autonomous entropy-based intelligent experimental design

    Science.gov (United States)

    Malakar, Nabin Kumar

    2011-07-01

    The aim of this thesis is to explore the application of probability and information theory in experimental design, and to do so in a way that combines what we know about inference and inquiry in a comprehensive and consistent manner. Present day scientific frontiers involve data collection at an ever-increasing rate. This requires that we find a way to collect the most relevant data in an automated fashion. By following the logic of the scientific method, we couple an inference engine with an inquiry engine to automate the iterative process of scientific learning. The inference engine involves Bayesian machine learning techniques to estimate model parameters based upon both prior information and previously collected data, while the inquiry engine implements data-driven exploration. By choosing an experiment whose distribution of expected results has the maximum entropy, the inquiry engine selects the experiment that maximizes the expected information gain. The coupled inference and inquiry engines constitute an autonomous learning method for scientific exploration. We apply it to a robotic arm to demonstrate the efficacy of the method. Optimizing inquiry involves searching for an experiment that promises, on average, to be maximally informative. If the set of potential experiments is described by many parameters, the search involves a high-dimensional entropy space. In such cases, a brute force search method will be slow and computationally expensive. We develop an entropy-based search algorithm, called nested entropy sampling, to select the most informative experiment. This helps to reduce the number of computations necessary to find the optimal experiment. We also extended the method of maximizing entropy, and developed a method of maximizing joint entropy so that it could be used as a principle of collaboration between two robots. This is a major achievement of this thesis, as it allows the information-based collaboration between two robotic units towards a same

  2. Stratified sampling design based on data mining.

    Science.gov (United States)

    Kim, Yeonkook J; Oh, Yoonhwan; Park, Sunghoon; Cho, Sungzoon; Park, Hayoung

    2013-09-01

    To explore classification rules based on data mining methodologies which are to be used in defining strata in stratified sampling of healthcare providers with improved sampling efficiency. We performed k-means clustering to group providers with similar characteristics, then, constructed decision trees on cluster labels to generate stratification rules. We assessed the variance explained by the stratification proposed in this study and by conventional stratification to evaluate the performance of the sampling design. We constructed a study database from health insurance claims data and providers' profile data made available to this study by the Health Insurance Review and Assessment Service of South Korea, and population data from Statistics Korea. From our database, we used the data for single specialty clinics or hospitals in two specialties, general surgery and ophthalmology, for the year 2011 in this study. Data mining resulted in five strata in general surgery with two stratification variables, the number of inpatients per specialist and population density of provider location, and five strata in ophthalmology with two stratification variables, the number of inpatients per specialist and number of beds. The percentages of variance in annual changes in the productivity of specialists explained by the stratification in general surgery and ophthalmology were 22% and 8%, respectively, whereas conventional stratification by the type of provider location and number of beds explained 2% and 0.2% of variance, respectively. This study demonstrated that data mining methods can be used in designing efficient stratified sampling with variables readily available to the insurer and government; it offers an alternative to the existing stratification method that is widely used in healthcare provider surveys in South Korea.

  3. Viability of the Fricke dosemeter doped with methylene blue; Viabilidade do dosimetro Fricke dopado com azul de metileno

    Energy Technology Data Exchange (ETDEWEB)

    Souza, V.L.B.; Santos, C.D.A.; Rodrigues, K.R.G.; Cunha, M.S.; Figueiredo, M.D.C.; Melo, R.T. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2009-07-01

    This work aims to find the possible utilization of the Fricke dosemeter doped with methylene blue (FMB) for the dosimetry of photodynamic therapy. The FMB was irradiated wit X rays and light emitted diodes demonstrating positive answers to the stimulus, being probably to be used for dosimetric objectives

  4. In-vivo dosimetry in radiotherapy: a comparison of the response of semiconductor and thermoluminescence (TLD700) dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Vynckier, S [Universite Catholique de Louvain, Brussels (Belgium). Cliniques Universitaires St. Luc; Greffe, J L; Loncol, T; Vanneste, F; Octave-Prignot, M; Denis, J M; De Patoul, N

    1995-12-01

    Semiconductor dosemeters and thermoluminescence dosemeters were calibrated in view of in-vivo dosimetry. Their response in a 8 MV photon beam and the respective correction factors for the treatment conditions were systematically studied. A total of 249 entrance and exit measurements with this dual detector combination were performed, mainly for treatments of the head and neck region. The resulting entrance and exit doses were compared with the expected doses at these positions, calculated on basis of the treatment and patient parameters. The results at the entrance showed a value of 1.010 (2.8% for the ratio of the measured to the calculated dose by diodes, 1.013) 4.9% for the ratio of the measured to the calculated dose by TLD and 1.003 (3.6% for the ratio of the measured dose by TLD to diodes. With respect the exit dose, the results were 0.998) 4.9%, 1.016 (7.7% and 1.019) 7.0% respectively after correction for the heterogeneity`s. Although the standard deviation for the TLD dosemeters is systematically larger than the standard deviation for the diodes, it is concluded that both dosemeters will yield similar results for-in-vivo dosimetry, if utilized under the same conditions.

  5. Technical specification of the NRPB thermoluminescent dosemeter used for the measurement of body dose and skin dose

    CERN Document Server

    Shaw, K B

    1977-01-01

    This report specifies the NRPB thermoluminescent dosemeter used for the measurement of radiation dose in tissue at a depth of 700 mg cm sup - sup 2 (body dose) and at a depth of 5-10 mg cm sup - sup 2 (skin dose).

  6. Synthesis-Based Software Architecture Design

    NARCIS (Netherlands)

    Tekinerdogan, B.; Aksit, Mehmet; Aksit, Mehmet

    2001-01-01

    During the last decade several architecture design approaches have been introduced. These approaches however have to cope with several obstacles and software architecture design remains a difficult problem. To cope with these obstacles this chapter introduces a novel architecture design approach.

  7. New developments of Czech Personnel Neutron Dosemeter and its application

    International Nuclear Information System (INIS)

    Trousil, J.; Spurny, F.; Kralik, M.; Zelenka, Z.

    2001-01-01

    There are two systems for neutron personal dosimetry used at practice in the Czech Republic: - solid state nuclear track detectors in contact with fissionable materials (intermetallic enriched U + AI alloy, and 232 Th) in Cd shield badge, and - Albedo dosimeter based on 6 LiF and 7 LiF thermoluminescent detectors in a plastic badge covered from the front side by Cd to screen it from directly coming thermalized neutrons. The first system is used in National Personal Dosimetry Service; its performance is continuously checked and improved. In this contribution we would like to present some of results of this development, the contribution to the calibration of the second system included. (authors)

  8. Rural Design Ethics Based on Four Dimensions

    Science.gov (United States)

    Zhang, Jiaxin; Zhu, Li

    2017-12-01

    China has a large rural area with a large population, whose architectural features, natural landscape, organizational structure and industrial structure are very different from that of cities. In the past, the contradictory between city and rural areas in China had negative effects on rural construction, resulting in a slow development. The excessive focus on city design has led to the neglect of rural design. Blindly using the concept and method of city design to renewed the countryside is a kind of destruction to the countryside, and also wastes a lot of construction resources. Design is influenced by ethical concepts, which needs to pay more attention to the culture tendency and society. Urban design makes theoretical investigation aiming at the ethical questions that emerged from city, then summarizes the design strategies of the city. While Chinese rural design has only begun to enter people’s horizon, and there is very little discussion about it. Due to the lack of ethical value guidance, Chinese rural design and construction has many problems at different levels of ecology, culture and industry. Therefore this paper primarily explores the domestic and foreign design ethics, attempting to provide a new perspective for Chinese rural design, aiming at finding a realistic and forward-looking solution for Chinese rural design concerning to the complex relation between city and rural areas.

  9. Michelson interferometer based interleaver design using classic IIR filter decomposition.

    Science.gov (United States)

    Cheng, Chi-Hao; Tang, Shasha

    2013-12-16

    An elegant method to design a Michelson interferometer based interleaver using a classic infinite impulse response (IIR) filter such as Butterworth, Chebyshev, and elliptic filters as a starting point are presented. The proposed design method allows engineers to design a Michelson interferometer based interleaver from specifications seamlessly. Simulation results are presented to demonstrate the validity of the proposed design method.

  10. Game Design Principles based on Human Error

    Directory of Open Access Journals (Sweden)

    Guilherme Zaffari

    2016-03-01

    Full Text Available This paper displays the result of the authors’ research regarding to the incorporation of Human Error, through design principles, to video game design. In a general way, designers must consider Human Error factors throughout video game interface development; however, when related to its core design, adaptations are in need, since challenge is an important factor for fun and under the perspective of Human Error, challenge can be considered as a flaw in the system. The research utilized Human Error classifications, data triangulation via predictive human error analysis, and the expanded flow theory to allow the design of a set of principles in order to match the design of playful challenges with the principles of Human Error. From the results, it was possible to conclude that the application of Human Error in game design has a positive effect on player experience, allowing it to interact only with errors associated with the intended aesthetics of the game.

  11. Simulation-based disassembly systems design

    Science.gov (United States)

    Ohlendorf, Martin; Herrmann, Christoph; Hesselbach, Juergen

    2004-02-01

    Recycling of Waste of Electrical and Electronic Equipment (WEEE) is a matter of actual concern, driven by economic, ecological and legislative reasons. Here, disassembly as the first step of the treatment process plays a key role. To achieve sustainable progress in WEEE disassembly, the key is not to limit analysis and planning to merely disassembly processes in a narrow sense, but to consider entire disassembly plants including additional aspects such as internal logistics, storage, sorting etc. as well. In this regard, the paper presents ways of designing, dimensioning, structuring and modeling different disassembly systems. Goal is to achieve efficient and economic disassembly systems that allow recycling processes complying with legal requirements. Moreover, advantages of applying simulation software tools that are widespread and successfully utilized in conventional industry sectors are addressed. They support systematic disassembly planning by means of simulation experiments including consecutive efficiency evaluation. Consequently, anticipatory recycling planning considering various scenarios is enabled and decisions about which types of disassembly systems evidence appropriateness for specific circumstances such as product spectrum, throughput, disassembly depth etc. is supported. Furthermore, integration of simulation based disassembly planning in a holistic concept with configuration of interfaces and data utilization including cost aspects is described.

  12. Study on routines and procedures of calibration of clinical dosemeter on gamma radiation beams at the IPEN-CNEN/SP, Brazil

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Santos, Gelson P.; Vivolo, Vitor

    2009-01-01

    The calibration consists in the comparison of the equipment to be calibrated with other equipment already calibrated by another standard, which means the equipment that will accomplish shall be considered secondary or tertiary, depending on the calibration that will be accomplished. As the clinical dosemeters are used for quality control services in the hospitals, these dosemeters need a reliable measurement precision. Therefore, this work intends to demonstrate the importance of the clinical dosemeter and the calibration, requiring special care face to all clinical set

  13. Influence of temperature in polymethylmethacrylate (PMMA) dosemeters response

    International Nuclear Information System (INIS)

    Napolitano, Celia Marina; Ferreira, Danilo Cardenuto; Camargo, Fabio de; Goncalves, Josemary Angelica Correa; Tobias, Carmen Cecilia Bueno

    2005-01-01

    The use of gamma irradiation sterilization processes in medical products and food preservation has encouraged the emergence of industrial facilities responsible for generation of doses as high as a few dozen kGy. The characterization of this radiation field requires the use of dosimeters with high spatial resolution, high resistance to radiation damage, maintenance of information absorbed doses at a time suitable for the analysis and processing of data, easy handling, etc. The dosimeters that meet most of these requirements are based on polymethylmethacrylate (PMMA) with dyes sensitive to radiation. The dose that can be measured with these dosimeters extends from 100Gy to 50kGy, with the estimated accuracies by manufacturers from 2 to 3%. However, in practice, there are procedures that require irradiation in different conditions of temperature, which results in changes in the response of the dosimeter. This way, considering the irradiations made in the center of radiation technology of Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP - Brazilian nuclear and energy research institute -, has studied the effect of temperature on the response of routine dosimeters PMMA type where the operational characteristics of Gammachrome YR dosimeters type and Red Perspex are being investigated respect to temperature and dose, whose results will be presented in this paper

  14. Chemical-Based Formulation Design: Virtual Experimentation

    DEFF Research Database (Denmark)

    Conte, Elisa; Gani, Rafiqul

    This paper presents a software, the virtual Product-Process Design laboratory (virtual PPD-lab) and the virtual experimental scenarios for design/verification of consumer oriented liquid formulated products where the software can be used. For example, the software can be employed for the design......, the additives and/or their mixtures (formulations). Therefore, the experimental resources can focus on a few candidate product formulations to find the best product. The virtual PPD-lab allows various options for experimentations related to design and/or verification of the product. For example, the selection...... design, model adaptation). All of the above helps to perform virtual experiments by blending chemicals together and observing their predicted behaviour. The paper will highlight the application of the virtual PPD-lab in the design and/or verification of different consumer products (paint formulation...

  15. Chemicals-Based Formulation Design: Virtual Experimentations

    DEFF Research Database (Denmark)

    Conte, Elisa; Gani, Rafiqul

    2011-01-01

    This paper presents a systematic procedure for virtual experimentations related to the design of liquid formulated products. All the experiments that need to be performed when designing a liquid formulated product (lotion), such as ingredients selection and testing, solubility tests, property mea...... on the design of an insect repellent lotion will show that the software is an essential instrument in decision making, and that it reduces time and resources since experimental efforts can be focused on one or few product alternatives....

  16. Reliability-Based Design of Coastal Structures

    DEFF Research Database (Denmark)

    Burcharth, H. F.

    1997-01-01

    The objective of this paper is to introduce the application of reliability theory for conceptual design and evaluation of coastal structures. It is without the scope to discuss the validity and quality of the various design formulae available for coastal structures. The contents of the paper is a....... Proceedings Conference of Port and Coastal Engineering in developing countries. Rio de Janeiro, Brazil, 1995....

  17. Experimental comparison between total calibration factors and components calibration factors of reference dosemeters used in secondary standard laboratory dosemeters

    International Nuclear Information System (INIS)

    Silva, T.A. da.

    1981-06-01

    A quantitative comparison of component calibration factors with the corresponding overall calibration factor was used to evaluate the adopted component calibration procedure in regard to parasitic elements. Judgement of significance is based upon the experimental uncertainty of a well established procedure for determination of the overall calibration factor. The experimental results obtained for different ionization chambers and different electrometers demonstrate that for one type of electrometer the parasitic elements have no influence on its sensitivity considering the experimental uncertainty of the calibration procedures. In this case the adopted procedure for determination of component calibration factors is considered to be equivalent to the procedure of determination of the overall calibration factor and thus might be used as a strong quality control measure in routine calibration. (Author) [pt

  18. Making Theory Come Alive through Practice-based Design Research

    DEFF Research Database (Denmark)

    Markussen, Thomas; Knutz, Eva; Rind Christensen, Poul

    The aim of this paper is to demonstrate how practice-based design research is able not only to challenge, but also to push toward further development of some of the basic assumpstions in emotion theories as used within design research. In so doing, we wish to increase knolwedge on a central...... epistemological question for design research, namely how practice-based design research can be a vehicle for the construction of new theory for design research....

  19. Embracing First-Person Perspectives in Soma-Based Design

    Directory of Open Access Journals (Sweden)

    Kristina Höök

    2018-02-01

    Full Text Available A set of prominent designers embarked on a research journey to explore aesthetics in movement-based design. Here we unpack one of the design sensitivities unique to our practice: a strong first person perspective—where the movements, somatics and aesthetic sensibilities of the designer, design researcher and user are at the forefront. We present an annotated portfolio of design exemplars and a brief introduction to some of the design methods and theory we use, together substantiating and explaining the first-person perspective. At the same time, we show how this felt dimension, despite its subjective nature, is what provides rigor and structure to our design research. Our aim is to assist researchers in soma-based design and designers wanting to consider the multiple facets when designing for the aesthetics of movement. The applications span a large field of designs, including slow introspective, contemplative interactions, arts, dance, health applications, games, work applications and many others.

  20. CRBRP structural and thermal margin beyond the design base

    International Nuclear Information System (INIS)

    Strawbridge, L.E.

    1979-01-01

    Prudent margins beyond the design base have been included in the design of Clinch River Breeder Reactor Plant to further reduce the risk to the public from highly improbable occurrences. These margins include Structural Margin Beyond the Design Base to address the energetics aspects and Thermal Margin Beyond the Design Base to address the longer term thermal and radiological consequences. The assessments that led to the specification of these margins are described, along with the experimental support for those assessments. 8 refs

  1. Design of LTCC Based Fractal Antenna

    KAUST Repository

    AdbulGhaffar, Farhan

    2010-01-01

    The thesis presents a Sierpinski Carpet fractal antenna array designed at 24 GHz for automotive radar applications. Miniaturized, high performance and low cost antennas are required for this application. To meet these specifications a fractal array

  2. Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemeters

    International Nuclear Information System (INIS)

    Maki, D.; Ishii, T.; Sato, F.; Kato, Y.; Yamamoto, T.; Iida, T.

    2011-01-01

    A confocal laser microscope system was developed for the measurement of radiophotoluminescence (RPL) photons emitted from a minute alpha-ray-irradiated area in an RPL glass dosemeter. The system was composed mainly of an inverted-type microscope, an ultraviolet laser, an XY movable stage and photon-counting circuits. The photon-counting circuits were effective in the reduction of the background noise level in the measurement of RPL photons. The performance of this microscope system was examined by the observation of standard RPL glass samples irradiated using 241 Am alpha rays. The spatial resolution of this system was ∼3 μm, and with regard to the sensitivity of this system, a hit of more than four to five alpha rays in unit area produced enough amount of RPL photons to construct the image. (authors)

  3. Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemeters.

    Science.gov (United States)

    Maki, Daisuke; Ishii, Tetsuya; Sato, Fuminobu; Kato, Yushi; Yamamoto, Takayoshi; Iida, Toshiyuki

    2011-03-01

    A confocal laser microscope system was developed for the measurement of radiophotoluminescence (RPL) photons emitted from a minute alpha-ray-irradiated area in an RPL glass dosemeter. The system was composed mainly of an inverted-type microscope, an ultraviolet laser, an XY movable stage and photon-counting circuits. The photon-counting circuits were effective in the reduction of the background noise level in the measurement of RPL photons. The performance of this microscope system was examined by the observation of standard RPL glass samples irradiated using (241)Am alpha rays. The spatial resolution of this system was ∼ 3 μm, and with regard to the sensitivity of this system, a hit of more than four to five alpha rays in unit area produced enough amount of RPL photons to construct the image.

  4. Results of film dosemeter control irradiations of German dose measurements services, 1969-1974

    International Nuclear Information System (INIS)

    Gummi, V.; Taubert, R.

    1976-01-01

    The dose measurement services of the FRG have been controlling themselves since 1961 by evaluating film dosimeters irradiated in the PTB under standard conditions. This control method is now embodied in a law by the second decree about the standardization of measuring instruments dt. 6th August 1975. During the time 1969-74 the PTB carried out more than 800 annual control irradiations of film dosimeters. In 30% of the cases the evaluation by the measuring services showed an errory higher than +50%/-30%. The dose measuring services partially diverge considerably concerning the distribution of evaluation errors. Particular difficulties seem to exist in the soft x-ray radiation with effective energies less than 30 keV, in the energy range about 100 keV, and in the evaluation of dosemeter irradiated with two different qualities of radiation (double irradiation). (orig.) [de

  5. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  6. Automation of radiation dosimetry using PTW dosemeter and LabVIEWTM

    International Nuclear Information System (INIS)

    Weiss, C.; Al-Frouh, K.; Anjak, O.

    2011-01-01

    Automation of UNIDOS 'Dosemeter' using personal computer (PC) is discussed in this paper. In order to save time and eliminate human operation errors during the radiation dosimetry, suitable software, using LabVIEW TM graphical programming language, was written to automate and facilitate the processes of measurements, analysis and data storage. The software calculates the calibration factor of the ionization chamber in terms of air kerma or absorbed dose to water according to IAEA dosimetry protocols. It also has the ability to print a calibration certificate. The obtained results using this software are found to be more reliable and flexible than those obtained by manual methods previously employed. Using LabVIEW TM as a development tool is extremely convenient to make things easier when software modifications and improvements are needed.

  7. Characterization of an active dosemeter according to IEC 61526:2010

    International Nuclear Information System (INIS)

    Cardoso, J.; Santos, L.; Santos, J.A.M.; Alves, J.G.; Oliveira, C.

    2016-01-01

    The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer. (authors)

  8. Track-etch dosemeter response to neutrons up to 300 MeV

    International Nuclear Information System (INIS)

    Devine, R.T.; Walker, S.; Staples, P.; Duran, M.; Mundis, R.; Miller, J.

    1996-01-01

    Electro-chemical and chemical track-etch dosemeters were obtained from commercial suppliers and exposed to neutrons produced at the LANTF WNR white neutron source at 15 degree with no shielding and filtered by polyethylene blocks of 2.5, 5.1, 10.2, 20.3 and 40.6 cin thickness. The neutron spectrum was determined using calculations. Mean energies from 28 to 300 MeV were produced. Dose was calculated from the NCRP-38 flux-to-dose conversion. The results are compared with NTA film which was exposed in the same configuration. The response of track etch dosimeters was found to reach a minimum and then rise as the average neutron energy increased. The response of the NTA film increased as the neutron energy increased

  9. Measurement analysis using the Fricke dosemeter; Analise de medicoes com o dosimetro Fricke

    Energy Technology Data Exchange (ETDEWEB)

    Pedrosa, G A.C. , [Instituto Nacional de Metrologia (INMETRO), Rio de Janeiro, RJ (Brazil); Dantas, C.C. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear], e-mail: ccd@ufpe.br; Campos, C.A. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)], e-mail: auster@elogica.com.br

    2003-07-01

    The Fricke dosemeter has been used for absolute determination of the radiation dose between 40 and 350 Gy for X-rays, Gamma rays and fast electrons energies. The great inconvenient of that dosimetric system is the impossibility of using for measurements of exposure or low dose rates. A Fricke dosimetry system was implanted at the Nuclear Sciences Regional Center (CRCN), in Recife, Pernambuco state, Brazil, for the determination of radiation doses for spectrometry and mass dosimetry with plasma source. The statistical analysis of the obtained results have shown that using the spectrometric method that system cna be used for maintenance of factors of CRCN standard calibrations and the dose assessment thru mail system of radiotherapy centers of the country.

  10. Photon beam audits for radiation therapy clinics: A pilot mailed dosemeter study in Turkey

    International Nuclear Information System (INIS)

    Yegingil, Z.; DeWerd, L. A.; Davis, S. D.; Hammer, C.; Kunugi, K.

    2012-01-01

    A thermoluminescent dosemeter (TLD) mailed dose audit programme was performed at five radiotherapy clinics in Turkey. The intercomparison was organised by the Univ. of Wisconsin Radiation Calibration Laboratory (UWRCL), which was responsible for the technical aspects of the study including reference irradiations, distribution, collection and evaluation. The purpose of these audits was to perform an independent dosimetry check of the radiation beams using TLDs sent by mail. Acrylic holders, each with five TLD chips inside and instructions for their irradiation to specified absorbed dose to water of 2 Gy, were mailed to all participating clinics. TLD irradiations were performed with a 6 MV linear accelerator and 60 Co photon beams. The deviations from the TL readings of UWRCL were calculated. Discrepancies inside the limits of ±5 % between the participant-stated dose, and the TLD-measured dose were considered acceptable. One out of 10 beams checked was outside this limit, with a difference of 5.8 %. (authors)

  11. Neutron spectrometry and dosimetry measurement at workplaces for calibration of individual PGP-DIN dosemeters

    International Nuclear Information System (INIS)

    Itie, C.; Muller, H.; Asselineau, B.; Medioni, R.; Crovisier, P.; Valier-Bradier, P.; Groetz, J.E.; Piot, J.

    2003-01-01

    Measurements to determine new coefficients for individual neutron dosimeters PGP-DIN complying with the ICRP 60 recommendations were performed at two workplaces at the CEA of Valduc: a storage room and a plutonium reprocessing plant. Two spectrometry campaigns were performed allowing a better assessment of doses received by operators working at these workplaces. Neutron energy fluence and ambient dose equivalent rate H * (10) distributions were measured as function of neutron energy by using the ROSPEC device and BONNER spheres spectrometer. The radiation field being mixed neutron and gamma, the gamma component was also evaluated: neutron and photon dose-rate meters were used to evaluate the ambient dose rate equivalent. Individual dosemeters were positioned on an ISO water slab phantom. In addition, calculations were performed using the MCNP simulation code for different configurations. (authors)

  12. Thermoluminescent dosemeter in a X-ray diffractometer; Dosimetria termoluminiscente en un difractometro de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico); Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, C.P. 76001, Queretaro (Mexico)

    1999-07-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  13. Distribution Network Design--literature study based

    OpenAIRE

    LI, ANG

    2012-01-01

    The focus of this research is companies' outbound distribution network design in supply chain management. Within the present competitive market, it is a fundamental importance for companies to achieve high level business performance with an effective supply chain. Outbound distribution network design as an important part in supply chain management, to a large extent decides whether companies can fulfill customers' requirement or not. Therefore, such a study is important for manufacturers and ...

  14. Performance of Panasonic ZP-1460 Electronic Personal Dosemeter under Exposure Conditions Likely to be Found at Fukushima Daiichi Nuclear Power Plant

    Science.gov (United States)

    Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro

    A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.

  15. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation (90Sr / 90Y)

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;α). Since H' (O. 07;α) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm -2 ); these dosemeters they were previously selected, [to see, S tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of 60 Co , J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of 90 Sr/ 90 Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of 90 Sr/ 90 Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass; four positions of irradiation is used: glass 1 (window of

  16. A framework for AI-based nuclear design support system

    International Nuclear Information System (INIS)

    Furuta, Kazuo; Kondo, Shunsuke

    1991-01-01

    Nowadays many computer programs are being developed and used for the analytic tasks in nuclear reactor design, but experienced designers are still responsible for most of the synthetic tasks which are not amenable to algorithmic computer processes. Artificial intelligence (AI) is a promising technology to deal with these intractable tasks in design. In development of AI-based design support systems, it is desirable to choose a comprehensive framework based on the scientific theory of design. In this work a framework for AI-based design support systems for nuclear reactor design will be proposed based on an exploration model of design. The fundamental architectures of this framework will be described especially on knowledge representation, context management and design planning. (author)

  17. Framework for AI-based nuclear reactor design support system

    International Nuclear Information System (INIS)

    Furuta, Kazuo; Kondo, Shunsuke

    1992-01-01

    Nowadays many computer programs are being developed and used for the analytic tasks in nuclear reactor design, but experienced designers are still responsible for most of the synthetic tasks which are not amenable to algorithmic computer processes. Artificial intelligence (AI) is a promising technology to deal with these intractable tasks in design. In development of AI-based design support systems, it is desirable to choose a comprehensive framework based on the scientific theory of design. In this work a framework for AI-based design support systems for nuclear reactor design will be proposed based on an explorative abduction model of design. The fundamental architectures of this framework will be described especially on knowledge representation, context management and design planning. (author)

  18. Model based design introduction: modeling game controllers to microprocessor architectures

    Science.gov (United States)

    Jungwirth, Patrick; Badawy, Abdel-Hameed

    2017-04-01

    We present an introduction to model based design. Model based design is a visual representation, generally a block diagram, to model and incrementally develop a complex system. Model based design is a commonly used design methodology for digital signal processing, control systems, and embedded systems. Model based design's philosophy is: to solve a problem - a step at a time. The approach can be compared to a series of steps to converge to a solution. A block diagram simulation tool allows a design to be simulated with real world measurement data. For example, if an analog control system is being upgraded to a digital control system, the analog sensor input signals can be recorded. The digital control algorithm can be simulated with the real world sensor data. The output from the simulated digital control system can then be compared to the old analog based control system. Model based design can compared to Agile software develop. The Agile software development goal is to develop working software in incremental steps. Progress is measured in completed and tested code units. Progress is measured in model based design by completed and tested blocks. We present a concept for a video game controller and then use model based design to iterate the design towards a working system. We will also describe a model based design effort to develop an OS Friendly Microprocessor Architecture based on the RISC-V.

  19. Optimal (Solvent) Mixture Design through a Decomposition Based CAMD methodology

    DEFF Research Database (Denmark)

    Achenie, L.; Karunanithi, Arunprakash T.; Gani, Rafiqul

    2004-01-01

    Computer Aided Molecular/Mixture design (CAMD) is one of the most promising techniques for solvent design and selection. A decomposition based CAMD methodology has been formulated where the mixture design problem is solved as a series of molecular and mixture design sub-problems. This approach is...

  20. Production of thermoluminescent dosemeters based on MgB{sub 4}O{sub 7}: Dy and MgB{sub 4}O{sub 7}: Tm; Producao de dosimetros termoluminescentes a base de MgB{sub 4}O{sub 7}: Dy e MgB{sub 4}O{sub 7}: Tm

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luiza Freire de; Souza, Divanizia N., E-mail: luizaf25@hotmail.com, E-mail: divanizi@ufs.br [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil). Programa de Pos-Graduacao em Fisica

    2013-07-01

    The thermoluminescent dosimetry (TL) is a well-established technique for the detection of ionizing radiation in hospitals, clinics, and industrial establishments where there is the need to quantify the radiation. For this practice is require the use phosphors which are sensitive to radiation. Some phosphors are already commonly used in this practice, for example, TLD-100 (LiF: Mg, Ti), CaSO{sub 4}:Tm and CaSO{sub 4}:Dy. A compound that was most recently introduced in dosimetry and has many advantageous features to detect neutrons, electrons and gamma is the magnesium tetraborate (MgB{sub 4}O{sub 7}), but the undoped material is not good for dosimetry, since signal does not show satisfactory thermoluminescence. The present work presents the analysis of the compound MgB{sub 4}O{sub 7} when doped with rare earth elements, thulium (Tm) and dysprosium (Dy). The production of MgB{sub 4}O{sub 7}: Dy and MgB{sub 4}O{sub 7}: Tm occurred under acidic conditions. Following the process of crystal growth, several tests were made on phosphors produced to verify the quality of materials as TL dosimeter. Initially, was made the identification of the crystalline phases found in the material, using the technique of X-ray diffractometry, and then were evaluated and compared the TL emission curves of the crystals with two different types of dopants, to this, the samples were irradiated with different radiation sources: {sup 137}Cs (0,66 MeV), {sup 60}Co (1.25 MeV) and X-rays (0.41 MeV) and based on the results was evaluated the energy dependence of phosphors. Another characteristic analyzed, was the decay of TL signal for the material (fading). The results show that the material can be an excellent TL dosimeter when doped with rare earth elements Dy and Tm. (author)

  1. LMI–based robust controller design approach in aircraft multidisciplinary design optimization problem

    Directory of Open Access Journals (Sweden)

    Qinghua Zeng

    2015-07-01

    Full Text Available This article proposes a linear matrix inequality–based robust controller design approach to implement the synchronous design of aircraft control discipline and other disciplines, in which the variation in design parameters is treated as equivalent perturbations. Considering the complicated mapping relationships between the coefficient arrays of aircraft motion model and the aircraft design parameters, the robust controller designed is directly based on the variation in these coefficient arrays so conservative that the multidisciplinary design optimization problem would be too difficult to solve, or even if there is a solution, the robustness of design result is generally poor. Therefore, this article derives the uncertainty model of disciplinary design parameters based on response surface approximation, converts the design problem of the robust controller into a problem of solving a standard linear matrix inequality, and theoretically gives a less conservative design method of the robust controller which is based on the variation in design parameters. Furthermore, the concurrent subspace approach is applied to the multidisciplinary system with this kind of robust controller in the design loop. A multidisciplinary design optimization of a tailless aircraft as example is shown that control discipline can be synchronous optimal design with other discipline, especially this method will greatly reduce the calculated amount of multidisciplinary design optimization and make multidisciplinary design optimization results more robustness of flight performance.

  2. Cognitive Activity-based Design Methodology for Novice Visual Communication Designers

    Science.gov (United States)

    Kim, Hyunjung; Lee, Hyunju

    2016-01-01

    The notion of design thinking is becoming more concrete nowadays, as design researchers and practitioners study the thinking processes involved in design and employ the concept of design thinking to foster better solutions to complex and ill-defined problems. The goal of the present research is to develop a cognitive activity-based design…

  3. FFTF fuel pin design bases and performance

    International Nuclear Information System (INIS)

    Cox, C.M.; Hanson, J.E.; Roake, W.E.; Slember, R.J.; Weber, C.E.; Millunzi, A.C.

    1975-04-01

    The FFTF fuel pin was conservatively designed to meet thermal and structural performance requirements in the categories normal operation, upset events, emergency events, and hypothetical, faulted events. The fuel pin operating limits consistent with these requirements were developed from a strong fuel pin irradiation testing program scoped to define the performance capability under relevant steady state and transient conditions. Comparison of the results of the irradiation testing program with design requirements indicates that the FFTF fuel pin can exceed its goal burnup of 80,000 MWd/MTM. (U.S.)

  4. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  5. Study of a selection of 10 historical types of dosemeter: variation of the response to Hp(10) with photon energy and geometry of exposure.

    Science.gov (United States)

    Thierry-Chef, I; Pernicka, F; Marshall, M; Cardis, E; Andreo, P

    2002-01-01

    An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.

  6. Designing Software-Based Interactive Installations

    DEFF Research Database (Denmark)

    Andreasen, Troels; Juul, Niels Christian; Rosendahl, Mads

    2014-01-01

    of the installation using tools like sketching or storyboarding. The design involves a clarification of available and appropriate building blocks, as well as the linking of these blocks to provide an architectural framework comprising the intended external behavior. The construction phase takes a component...

  7. Driving Force Based Design of Cyclic Distillation

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Fjordbak; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2017-01-01

    with mixed phase feeds. A range of binary test cases, benzene toluene, methanol water, and ethanol water, are evaluated. The advantage of the design approach in cyclic distillation is shown to be analogous to the advantages obtained in conventional continuous distillation, including a minimal utility...

  8. Regression Discontinuity Designs Based on Population Thresholds

    DEFF Research Database (Denmark)

    Eggers, Andrew C.; Freier, Ronny; Grembi, Veronica

    In many countries, important features of municipal government (such as the electoral system, mayors' salaries, and the number of councillors) depend on whether the municipality is above or below arbitrary population thresholds. Several papers have used a regression discontinuity design (RDD...

  9. The LACIE data bases: Design considerations

    Science.gov (United States)

    Westberry, L. E. (Principal Investigator)

    1979-01-01

    The implementation of direct access storage devices for LACIE is discussed with emphasis on the storage and retrieval of image data. Topics covered include the definition of the problem, the solution methodology (design decisions), the initial operational structure, and the modifications which were incorporated. Some conclusions and projections of future problems to be solved are also presented.

  10. Design of molecule-based magnetic conductors

    NARCIS (Netherlands)

    Akhtar, Naureen; Blake, Graeme R.; Felici, Roberto; Amenitsch, Heinz; Palstra, Thomas T. M.; Rudolf, Petra

    2014-01-01

    Enabling the use of rationally designed thin films in technological devices is a recognized goal in materials science. However, constructing such thin films using highly ordered supramolecular architectures with well-controlled size and growth direction has remained an elusive target. Here, we

  11. NUCLEAR SAFETY DESIGN BASES FOR LICENSE APPLICATION

    International Nuclear Information System (INIS)

    Garrett, R.J.

    2005-01-01

    The purpose of this report is to identify and document the nuclear safety design requirements that are specific to structures, systems, and components (SSCs) of the repository that are important to safety (ITS) during the preclosure period and to support the preclosure safety analysis and the license application for the high-level radioactive waste (HLW) repository at Yucca Mountain, Nevada. The scope of this report includes the assignment of nuclear safety design requirements to SSCs that are ITS and does not include the assignment of design requirements to SSCs or natural or engineered barriers that are important to waste isolation (ITWI). These requirements are used as input for the design of the SSCs that are ITS such that the preclosure performance objectives of 10 CFR 63.111 [DIRS 156605] are met. The natural or engineered barriers that are important to meeting the postclosure performance objectives of 10 CFR 63.113 [DIRS 156605] are identified as ITWI. Although a structure, system, or component (SSC) that is ITS may also be ITWI, this report is only concerned with providing the nuclear safety requirements for SSCs that are ITS to prevent or mitigate event sequences during the repository preclosure period

  12. Nuclear Safety Design Base for License Application

    International Nuclear Information System (INIS)

    R.J. Garrett

    2005-01-01

    The purpose of this report is to identify and document the nuclear safety design requirements that are specific to structures, systems, and components (SSCs) of the repository that are important to safety (ITS) during the preclosure period and to support the preclosure safety analysis and the license application for the high-level radioactive waste (HLW) repository at Yucca Mountain, Nevada. The scope of this report includes the assignment of nuclear safety design requirements to SSCs that are ITS and does not include the assignment of design requirements to SSCs or natural or engineered barriers that are important to waste isolation (ITWI). These requirements are used as input for the design of the SSCs that are ITS such that the preclosure performance objectives of 10 CFR 63.111(b) [DIRS 173273] are met. The natural or engineered barriers that are important to meeting the postclosure performance objectives of 10 CFR 63.113(b) and (c) [DIRS 173273] are identified as ITWI. Although a structure, system, or component (SSC) that is ITS may also be ITWI, this report is only concerned with providing the nuclear safety requirements for SSCs that are ITS to prevent or mitigate event sequences during the repository preclosure period

  13. A Contradiction-Based Approach for Innovative Product Design

    Directory of Open Access Journals (Sweden)

    Ko Yao-Tsung

    2016-01-01

    Full Text Available Without creativity in design there is no potential for innovation. This paper investigates the role of contradictions in enhancing creativity in product design. Based on the inventive principles of TRIZ, this paper presents a novel design method by integrating technical and physical contradiction analysis methods into the conceptual design activities of new product development (NPD. Despite the recognized importance of innovative design, there is a lack of the systematic and effective design-thinking process that can covers all conceptual design activities. To address this gap, a sharper and fundamental model of the problem-solving is created for innovative product design based on the contradiction-oriented concept. Eventually, one case study is employed to illustrate the method and the result validates that it can help designers produce more creative outcomes in product design.

  14. A Framework for IT-based Design Tools

    DEFF Research Database (Denmark)

    Hartvig, Susanne C

    The thesis presents a new apprach to develop design tools that can be integrated, bypresenting a framework consisting of a set of guidelines for design tools, an integration andcommunication scheme, and a set of design tool schemes.This framework has been based onanalysis of requirements to integ...... to integrated design enviornments, and analysis of engineeringdesign and design problem solving methods. And the developed framework has been testedby applying it to development of prototype design tools for realistic design scenarios.......The thesis presents a new apprach to develop design tools that can be integrated, bypresenting a framework consisting of a set of guidelines for design tools, an integration andcommunication scheme, and a set of design tool schemes.This framework has been based onanalysis of requirements...

  15. Design Scheme of Remote Monitoring System Based on Qt

    Directory of Open Access Journals (Sweden)

    Xu Dawei

    2015-01-01

    Full Text Available This paper introduces a design scheme of remote monitoring system based on Qt, the scheme of remote monitoring system based on S3C2410 and Qt, with the aid of cross platform development tools Qt and powerful ARM platform design and implementation. The development of remote video surveillance system based on embedded terminal has practical significance and value.

  16. Finite element based electric motor design optimization

    Science.gov (United States)

    Campbell, C. Warren

    1993-01-01

    The purpose of this effort was to develop a finite element code for the analysis and design of permanent magnet electric motors. These motors would drive electromechanical actuators in advanced rocket engines. The actuators would control fuel valves and thrust vector control systems. Refurbishing the hydraulic systems of the Space Shuttle after each flight is costly and time consuming. Electromechanical actuators could replace hydraulics, improve system reliability, and reduce down time.

  17. Design of Threshold Controller Based Chaotic Circuits

    DEFF Research Database (Denmark)

    Mohamed, I. Raja; Murali, K.; Sinha, Sudeshna

    2010-01-01

    We propose a very simple implementation of a second-order nonautonomous chaotic oscillator, using a threshold controller as the only source of nonlinearity. We demonstrate the efficacy and simplicity of our design through numerical and experimental results. Further, we show that this approach...... of using a threshold controller as a nonlinear element, can be extended to obtain autonomous and multiscroll chaotic attractor circuits as well....

  18. Judgement of Design Scheme Based on Flexible Constraint in ICAD

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The conception of flexible constraint is proposed in the paper. The solution of flexible constraint is in special range, and maybe different in different instances of same design scheme. The paper emphasis on how to evaluate and optimize a design scheme with flexible constraints based on the satisfaction degree function defined on flexible constraints. The conception of flexible constraint is used to solve constraint conflict and design optimization in complicated constraint-based assembly design by the PFM parametrization assembly design system. An instance of gear-box design is used for verifying optimization method.

  19. Sequential experimental design based generalised ANOVA

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Souvik, E-mail: csouvik41@gmail.com; Chowdhury, Rajib, E-mail: rajibfce@iitr.ac.in

    2016-07-15

    Over the last decade, surrogate modelling technique has gained wide popularity in the field of uncertainty quantification, optimization, model exploration and sensitivity analysis. This approach relies on experimental design to generate training points and regression/interpolation for generating the surrogate. In this work, it is argued that conventional experimental design may render a surrogate model inefficient. In order to address this issue, this paper presents a novel distribution adaptive sequential experimental design (DA-SED). The proposed DA-SED has been coupled with a variant of generalised analysis of variance (G-ANOVA), developed by representing the component function using the generalised polynomial chaos expansion. Moreover, generalised analytical expressions for calculating the first two statistical moments of the response, which are utilized in predicting the probability of failure, have also been developed. The proposed approach has been utilized in predicting probability of failure of three structural mechanics problems. It is observed that the proposed approach yields accurate and computationally efficient estimate of the failure probability.

  20. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 4037 consists of the following parts, under the general title X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy: Part 1: Radiation characteristics and production methods; Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV; Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence; Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields. This part 4. of ISO 4037 gives guidelines on additional aspects of the characterization of low energy photon radiations. This part of ISO 4037 also describes procedures for calibration and determination of the response of area and personal dose(rate)meters as a function of photon energy and angle of incidence. This part of ISO 4037 concentrates on the accurate determination of conversion coefficients from air kerma to Hp(10) and H*(10) for the spectra of low energy photon radiations. As an alternative to the use of conversion coefficients, the direct calibration in terms of these quantities by means of appropriate reference instruments is described

  1. Making Design Decisions Visible: Applying the Case-Based Method in Designing Online Instruction

    Directory of Open Access Journals (Sweden)

    Heng Luo,

    2011-01-01

    Full Text Available The instructional intervention in this design case is a self-directed online tutorial that applies the case-based method to teach educators how to design and conduct entrepreneurship programs for elementary school students. In this article, the authors describe the major decisions made in each phase of the design and development process, explicate the rationales behind them, and demonstrate their effect on the production of the tutorial. Based on such analysis, the guidelines for designing case-based online instruction are summarized for the design case.

  2. Integrating Design Decision Management with Model-based Software Development

    DEFF Research Database (Denmark)

    Könemann, Patrick

    Design decisions are continuously made during the development of software systems and are important artifacts for design documentation. Dedicated decision management systems are often used to capture such design knowledge. Most such systems are, however, separated from the design artifacts...... of the system. In model-based software development, where design models are used to develop a software system, outcomes of many design decisions have big impact on design models. The realization of design decisions is often manual and tedious work on design models. Moreover, keeping design models consistent......, or by ignoring the causes. This substitutes manual reviews to some extent. The concepts, implemented in a tool, have been validated with design patterns, refactorings, and domain level tests that comprise a replay of a real project. This proves the applicability of the solution to realistic examples...

  3. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    Science.gov (United States)

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  4. New ICRU quantities for the environmental and individual monitoring. Standardization of individual dosemeters by using external beams of photon radiation

    International Nuclear Information System (INIS)

    Brosed, A.; Delgado, A.; Granados, C. E.

    1987-01-01

    The quantities introduced by ICRU for the radiological monitoring are commented, specially those implied in individual protection against external photons. A procedure is proposed in order to standardize the individual dosemeters by using the kerma in air references of CIEMAT-JEN. The reference radiation beams are described in connection with ISO standards. Provisional values are selected for the appropriate conversion and correction factors. (Author) 23 refs

  5. Preparation of the FXG gel dosemeter and studying its response for low and medium energy X-rays

    International Nuclear Information System (INIS)

    Bero, M.; Kharita, M. H.

    2008-02-01

    Gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different response for low and medium energies X-rays in comparison with high energy-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100 - 300 kv. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0 - 8 Gy. This work includes in the first stage the preparation of the radiochromic gel dosemeter (FXG) as well as its calibration in gamma radiation field. Furthermore, the stability and reproducibility of measurements were tested. The obtained results were found to be suitable as a basis to carry on the next stage of this study. The second phase was centred about the delivery of radiation doses from X-ray source that has increasing energy and evaluating the gel material properties as a dosemeter in this case, with concentration on finding the changes of the gel material response with the changes in the applied X-ray energy. Therefore establishing the response radiation energy dependence and comparing the measurement results with other results taken from other known dosimetry system such as ion chambers. Experiments shows that the FXG gel detector has a dynamic rage suitable for the dose delivered in radiotherapy treatment; its response as a function of the dose rate is also stable in the range of radiation energies applied.(Author)

  6. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  7. Rational design of gene-based vaccines.

    Science.gov (United States)

    Barouch, Dan H

    2006-01-01

    Vaccine development has traditionally been an empirical discipline. Classical vaccine strategies include the development of attenuated organisms, whole killed organisms, and protein subunits, followed by empirical optimization and iterative improvements. While these strategies have been remarkably successful for a wide variety of viruses and bacteria, these approaches have proven more limited for pathogens that require cellular immune responses for their control. In this review, current strategies to develop and optimize gene-based vaccines are described, with an emphasis on novel approaches to improve plasmid DNA vaccines and recombinant adenovirus vector-based vaccines. Copyright 2006 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  8. Computer Aided Design Parameters for Forward Basing

    Science.gov (United States)

    1988-12-01

    This is a professional drawing package, 19 capable of the manipulation required for this project. With the AutoLISP programming language (a variation on...Table 2). 0 25 Data Conversion Package II GWN System’s Digital Terrain Modeling (DTM) package was used. This AutoLISP -based third party software is...Base Module of GWN System’s GWN- DTM software. A simple AutoLISP conversion program (TA2DXF, TA2DXB) within the software converts the TA2 format into an

  9. Designing Personalization in Technology-Based Services

    Science.gov (United States)

    Lee, Min Kyung

    2013-01-01

    Personalization technology has the potential to optimize service for each person's unique needs and characteristics. One way to optimize service is to allow people to customize the service themselves; another is to proactively tailor services based on information provided by people or inferred from their past behaviors. These approaches function…

  10. Design of MPU based process monitoring instrument

    International Nuclear Information System (INIS)

    Ahmed, Z.; Qamar, R.; Majid, B.

    1995-03-01

    A display sub-system (DSS) for a process variable like flow is designed around Intel 8088 microprocessor. It displays the current value of a process variable but average and accumulated value display is manually selectable. The display consists of 6 units of seven segment display and accuracy up to 2 nd place of decimal is achieved. The engineering units are indicated by the LEDs. The control software is developed in assembler and burnt in a EPROM. The maximum value of the display is 9999.99 K. liter and that of time is 99 days 23 hours and 59 minutes. Sampling period is 1 second. Data acquisition is done using Polling technique. (author)

  11. Controller design approach based on linear programming.

    Science.gov (United States)

    Tanaka, Ryo; Shibasaki, Hiroki; Ogawa, Hiromitsu; Murakami, Takahiro; Ishida, Yoshihisa

    2013-11-01

    This study explains and demonstrates the design method for a control system with a load disturbance observer. Observer gains are determined by linear programming (LP) in terms of the Routh-Hurwitz stability criterion and the final-value theorem. In addition, the control model has a feedback structure, and feedback gains are determined to be the linear quadratic regulator. The simulation results confirmed that compared with the conventional method, the output estimated by our proposed method converges to a reference input faster when a load disturbance is added to a control system. In addition, we also confirmed the effectiveness of the proposed method by performing an experiment with a DC motor. © 2013 ISA. Published by ISA. All rights reserved.

  12. Product design pattern based on big data-driven scenario

    Directory of Open Access Journals (Sweden)

    Conggang Yu

    2016-07-01

    Full Text Available This article discusses about new product design patterns in the big data era, gives designer a new rational thinking way, and is a new way to understand the design of the product. Based on the key criteria of the product design process, category, element, and product are used to input the data, which comprises concrete data and abstract data as an enlargement of the criteria of product design process for the establishment of a big data-driven product design pattern’s model. Moreover, an experiment and a product design case are conducted to verify the feasibility of the new pattern. Ultimately, we will conclude that the data-driven product design has two patterns: one is the concrete data supporting the product design, namely “product–data–product” pattern, and the second is based on the value of the abstract data for product design, namely “data–product–data” pattern. Through the data, users are involving themselves in the design development process. Data and product form a huge network, and data plays a role of connection or node. So the essence of the design is to find a new connection based on element, and to find a new node based on category.

  13. Introducing Project-Based Learning to Design Enterprises for Creativity

    DEFF Research Database (Denmark)

    Wang, Feng; Zhou, Chunfang; Chen, Hongbing

    2013-01-01

    This paper aims to emphasize the necessity of introducing Project-Based Learning (PBL) to design enterprises in order to foster designers creativity and facilitate innovation of design enterprises. According to the literature review, creativity can be viewed as the first stage of innovation; PBL...

  14. Design Application Early Childhood Education Based Mobile

    Directory of Open Access Journals (Sweden)

    Annah

    2016-02-01

    Full Text Available This study aims to make learning media for Early Childhood Education in the form especially its mobile applications for Android-based smartphones. In the process of teaching and learning for Early Childhood Education is still often found constraints experienced teaching force is limited props so that learners are less eager to learn. In addition, parents also have difficulty returning to guide or teach the learning materials at home because it has no alternative instructional media. In compiling this research report author uses the Android-based Mobile Devices Applications created using the Java programming language through the Eclipse editor. Based on the results of the research, concluded that these applications can be applied in the latest version of the Android platform to its current platform version of Jellybean. Application of Learning can be used as an alternative way of learning for Early Childhood Education so as to overcome the lack of props in institutions of Early Childhood Education, can be used to be taught at home, and provide new teaching methods to early childhood so that a form of learning that is obtained is not the monotony of one form of learning how.

  15. The challenge of integrating evidence-based design.

    Science.gov (United States)

    Martin, Caren S

    2009-01-01

    This paper discusses the integration of evidence-based design (EBD) into the design process as an innovation, illuminates the significance and progress of the diffusion of this innovation, and identifies EBD advocates and the consequences of meeting the EBD challenge. A free tool for engaging in EBD is explored. Healthcare designers are leading the EBD charge, because their clients depend on it. But not all designers engage in EBD, because it may be beyond the resources of a firm or outside its culture. However, as with other meaningful design innovations, designers who do not practice EBD could fall by the wayside. EBD is a product of the diffusion of the innovation of evidence-based medicine. The academy (i.e., the collective of institutions of higher education), design organizations, design communities, and the media all contribute to the diffusion of EBD. However, the quantity, quality, and understandability of evidence continue to challenge its broad adoption. InformeDesign®, a free, Internet-based tool, presents information to designers in a concise, understandable way. Firms must invest in EBD incrementally as a value-added component of design to meet current and future challenges. It is important for designers to realize that engaging in EBD is not a rejection of creativity, but a means by which to elevate their design solutions. ©2009 VENDOME GROUP, LLC

  16. Reflection: Research by Design: Design-Based Research and the Higher Degree Research Student

    Science.gov (United States)

    Kennedy-Clark, Shannon

    2015-01-01

    The article "Research by design: Design-based research and the higher degree research student" (Kennedy-Clark, 2013) appeared in the "Journal of Learning Design" Volume 6, Issue 2 in 2013. Two years on, Shannon Kennedy-Clark reflects upon her original article. Upon being asked to revisit this article the author reflected upon…

  17. Building a Case-Based Design Assistant for Workplace Environment Design

    NARCIS (Netherlands)

    Mallory-Hill, S.M.; Timmermans, H.J.P.

    1998-01-01

    This paper reports on the early stages of development of a case-based design tool. The purpose of this tool, called the Workplace Environment Design Advisor (WEDA), is to support architects in the conceptual design of workplace environments. The objective of this system is to provide electronic

  18. Probability based load factors for design of concrete containment structures

    International Nuclear Information System (INIS)

    Hwang, H.; Kagami, S.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper describes a procedure for developing probability-based load combinations for the design of concrete containments. The proposed criteria are in a load and resistance factor design (LRFD) format. The load factors and resistance factors are derived for use in limit states design and are based on a target limit state probability. In this paper, the load factors for accident pressure and safe shutdown earthquake are derived for three target limit state probabilities. Other load factors are recommended on the basis of prior experience with probability-based design criteria for ordinary building construction. 6 refs

  19. Conceptual design of jewellery: a space-based aesthetics approach

    Directory of Open Access Journals (Sweden)

    Tzintzi Vaia

    2017-01-01

    Full Text Available Conceptual design is a field that offers various aesthetic approaches to generation of nature-based product design concepts. Essentially, Conceptual Product Design (CPD uses similarities based on the geometrical forms and functionalities. Furthermore, the CAD-based freehand sketch is a primary conceptual tool in the early stages of the design process. The proposed Conceptual Product Design concept is dealing with jewelleries that are inspired from space. Specifically, a number of galaxy features, such as galaxy shapes, wormholes and graphical representation of planet magnetic field are used as inspirations. Those space-based design ideas at a conceptual level can lead to further opportunities for research and economic success of the jewellery industry. A number of illustrative case studies are presented and new opportunities can be derived for economic success.

  20. A Distributed Feature-based Environment for Collaborative Design

    Directory of Open Access Journals (Sweden)

    Wei-Dong Li

    2003-02-01

    Full Text Available This paper presents a client/server design environment based on 3D feature-based modelling and Java technologies to enable design information to be shared efficiently among members within a design team. In this environment, design tasks and clients are organised through working sessions generated and maintained by a collaborative server. The information from an individual design client during a design process is updated and broadcast to other clients in the same session through an event-driven and call-back mechanism. The downstream manufacturing analysis modules can be wrapped as agents and plugged into the open environment to support the design activities. At the server side, a feature-feature relationship is established and maintained to filter the varied information of a working part, so as to facilitate efficient information update during the design process.

  1. Design of silicon-based fractal antennas

    KAUST Repository

    Ghaffar, Farhan A.

    2012-11-20

    This article presents Sierpinski carpet fractal antennas implemented in conventional low resistivity (Ï =10 Ω cm) as well as high resistivity (Ï =1500 Ω cm) silicon mediums. The fractal antenna is 36% smaller as compared with a typical patch antenna at 24 GHz and provides 13% bandwidth on high resistivity silicon, suitable for high data rate applications. For the first time, an on-chip fractal antenna array is demonstrated in this work which provides double the gain of a single fractal element as well as enhanced bandwidth. A custom test fixture is utilized to measure the radiation pattern and gain of these probe-fed antennas. In addition to gain and impedance characterization, measurements have also been made to study intrachip communication through these antennas. The comparison between the low resistivity and high resistivity antennas indicate that the former is not a suitable medium for array implementation and is only suitable for short range communication whereas the latter is appropriate for short and medium range wireless communication. The design is well-suited for compact, high data rate System-on-Chip (SoC) applications as well as for intrachip communication such as wireless global clock distribution in synchronous systems. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 55:180-186, 2013; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27245 Copyright © 2012 Wiley Periodicals, Inc.

  2. Design of silicon-based fractal antennas

    KAUST Repository

    Ghaffar, Farhan A.; Shamim, Atif

    2012-01-01

    This article presents Sierpinski carpet fractal antennas implemented in conventional low resistivity (Ï =10 Ω cm) as well as high resistivity (Ï =1500 Ω cm) silicon mediums. The fractal antenna is 36% smaller as compared with a typical patch antenna at 24 GHz and provides 13% bandwidth on high resistivity silicon, suitable for high data rate applications. For the first time, an on-chip fractal antenna array is demonstrated in this work which provides double the gain of a single fractal element as well as enhanced bandwidth. A custom test fixture is utilized to measure the radiation pattern and gain of these probe-fed antennas. In addition to gain and impedance characterization, measurements have also been made to study intrachip communication through these antennas. The comparison between the low resistivity and high resistivity antennas indicate that the former is not a suitable medium for array implementation and is only suitable for short range communication whereas the latter is appropriate for short and medium range wireless communication. The design is well-suited for compact, high data rate System-on-Chip (SoC) applications as well as for intrachip communication such as wireless global clock distribution in synchronous systems. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 55:180-186, 2013; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27245 Copyright © 2012 Wiley Periodicals, Inc.

  3. Physiological Based Simulator Fidelity Design Guidance

    Science.gov (United States)

    Schnell, Thomas; Hamel, Nancy; Postnikov, Alex; Hoke, Jaclyn; McLean, Angus L. M. Thom, III

    2012-01-01

    The evolution of the role of flight simulation has reinforced assumptions in aviation that the degree of realism in a simulation system directly correlates to the training benefit, i.e., more fidelity is always better. The construct of fidelity has several dimensions, including physical fidelity, functional fidelity, and cognitive fidelity. Interaction of different fidelity dimensions has an impact on trainee immersion, presence, and transfer of training. This paper discusses research results of a recent study that investigated if physiological-based methods could be used to determine the required level of simulator fidelity. Pilots performed a relatively complex flight task consisting of mission task elements of various levels of difficulty in a fixed base flight simulator and a real fighter jet trainer aircraft. Flight runs were performed using one forward visual channel of 40 deg. field of view for the lowest level of fidelity, 120 deg. field of view for the middle level of fidelity, and unrestricted field of view and full dynamic acceleration in the real airplane. Neuro-cognitive and physiological measures were collected under these conditions using the Cognitive Avionics Tool Set (CATS) and nonlinear closed form models for workload prediction were generated based on these data for the various mission task elements. One finding of the work described herein is that simple heart rate is a relatively good predictor of cognitive workload, even for short tasks with dynamic changes in cognitive loading. Additionally, we found that models that used a wide range of physiological and neuro-cognitive measures can further boost the accuracy of the workload prediction.

  4. NMR in structure-based drug design.

    Science.gov (United States)

    Carneiro, Marta G; Ab, Eiso; Theisgen, Stephan; Siegal, Gregg

    2017-11-08

    NMR spectroscopy is a powerful technique that can provide valuable structural information for drug discovery endeavors. Here, we discuss the strengths (and limitations) of NMR applications to structure-based drug discovery, highlighting the different levels of resolution and throughput obtainable. Additionally, the emerging field of paramagnetic NMR in drug discovery and recent developments in approaches to speed up and automate protein-observed NMR data collection and analysis are discussed. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  5. Olfoto: designing a smell-based interaction

    OpenAIRE

    Brewster, S.A.; McGookin, D.K.; Miller, C.A.

    2006-01-01

    We present a study into the use of smell for searching digi-tal photo collections. Many people now have large photo libraries on their computers and effective search tools are needed. Smell has a strong link to memory and emotion so may be a good way to cue recall when searching. Our study compared text and smell based tagging. For the first stage we generated a set of smell and tag names from user de-scriptions of photos, participants then used these to tag pho-tos, returning two weeks later...

  6. Reliability-based design of wind turbine blades

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2011-01-01

    Reliability-based design of wind turbine blades requires identification of the important failure modes/limit states along with stochastic models for the uncertainties and methods for estimating the reliability. In the present paper it is described how reliability-based design can be applied to wi...

  7. Computer-Aided Test Flow in Core-Based Design

    NARCIS (Netherlands)

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of

  8. Implementing Project Based Learning Approach to Graphic Design Course

    Science.gov (United States)

    Riyanti, Menul Teguh; Erwin, Tuti Nuriah; Suriani, S. H.

    2017-01-01

    The purpose of this study was to develop a learning model based Commercial Graphic Design Drafting project-based learning approach, was chosen as a strategy in the learning product development research. University students as the target audience of this model are the students of the fifth semester Visual Communications Design Studies Program…

  9. Issues in Text Design and Layout for Computer Based Communications.

    Science.gov (United States)

    Andresen, Lee W.

    1991-01-01

    Discussion of computer-based communications (CBC) focuses on issues involved with screen design and layout for electronic text, based on experiences with electronic messaging, conferencing, and publishing within the Australian Open Learning Information Network (AOLIN). Recommendations for research on design and layout for printed text are also…

  10. Product design pattern based on big data-driven scenario

    OpenAIRE

    Conggang Yu; Lusha Zhu

    2016-01-01

    This article discusses about new product design patterns in the big data era, gives designer a new rational thinking way, and is a new way to understand the design of the product. Based on the key criteria of the product design process, category, element, and product are used to input the data, which comprises concrete data and abstract data as an enlargement of the criteria of product design process for the establishment of a big data-driven product design pattern’s model. Moreover, an exper...

  11. Urban Environment Development based on Universal Design Principles

    Science.gov (United States)

    Harsritanto, Bangun Ir

    2018-02-01

    Universal Design is a design which facilitated full range of human diversity. By applying Universal design principles, urban environment can be more functional and more user-friendly for everyone. This study examined five urban streets of South Korea as a country experienced on developing various urban street designs based on universal design. This study aimed to examine and compare the South Korea cases using seven principles of universal design. The research methods of this study are literature study, case study, and site observation. The results of this study are: South Korea cases are good practices, urgency of implementing the direction into local regulations; and change of urban development paradigm.

  12. Design of reactor alarm instrument based on SOPC

    International Nuclear Information System (INIS)

    Li Meng; Lu Yi; Rong Ru

    2008-01-01

    The design of embedded alarm instrument in reactors based on Nios II CPU is introduced in this paper. This design uses the SOPC technology based on the Cyclone series FPGA as a digital bench, and connects the MPU and drivers and interface of times, RS232, sdram,and etc. into a FPGA chip. It is proved that the system achieves the design goals in primary experimentation. (authors)

  13. Design considerations for a multiprocessor based data acquisition system

    International Nuclear Information System (INIS)

    Tippie, J.W.; Kulaga, J.E.

    1979-01-01

    The rapid advance of digital technology has provided the systems designer with many new design options. Hardware is no longer the controlling expense. Complex operating systems provide the flexibility and development tools needed by software designers, but restrict throughput. Multiprocessor-based systems can be used to ''front-end'' high-throughput applications while maintaining the many advantages offered by multitasking operating systems. The design of a high-throughput data acquisition system for application in low energy nuclear physics is considered

  14. The Research of Design Based on Social Commerce

    OpenAIRE

    Juhua Wu; Meng Xu; Zan Mo; Luo Liao

    2015-01-01

    Based on previous design theories which focus only on artifacts, we study the factors of social commerce design with application environment and human capabilities. By comparing social commerce design model and information model, we develop a new social commerce design model, further exploring user requirements after shopping, including the exploration of brand community, sharing offline social shopping experience and the improvement of user social skills. According to the new model, we revea...

  15. Design of control system based on SCM music fountain

    Science.gov (United States)

    Li, Biqing; Li, Zhao; Jiang, Suping

    2018-06-01

    The design of the design of a microprocessor controlled by simple circuit, introduced this design applied to the components, and draw the main flow chart presentation. System is the use of an external music source, the intensity of the input audio signal lights will affect the light off, the fountain spray of water level will be based on changes in the lantern light off. This design uses a single-chip system is simple, powerful, good reliability and low cost.

  16. Using a Design Science Perspective to Understand a Complex Design-Based Research Process

    DEFF Research Database (Denmark)

    Bækgaard, Lars

    2012-01-01

    The purpose of the paper is to demonstrate how a design science perspective can be used to describe and understand a set of related design-based research processes. We describe and analyze a case study in a manner that is inspired by design science. The case study involves the design of modeling......-based research processes. And we argue that a design science perspective may be useful for both researchers and practitioners....... tools and the redesign of an information service in a library. We use a set of guidelines from a design science perspective to organize the description and analysis of the case study. By doing this we demonstrate the usefulness of design science as an analytical tool for understanding related design...

  17. Embracing model-based designs for dose-finding trials.

    Science.gov (United States)

    Love, Sharon B; Brown, Sarah; Weir, Christopher J; Harbron, Chris; Yap, Christina; Gaschler-Markefski, Birgit; Matcham, James; Caffrey, Louise; McKevitt, Christopher; Clive, Sally; Craddock, Charlie; Spicer, James; Cornelius, Victoria

    2017-07-25

    Dose-finding trials are essential to drug development as they establish recommended doses for later-phase testing. We aim to motivate wider use of model-based designs for dose finding, such as the continual reassessment method (CRM). We carried out a literature review of dose-finding designs and conducted a survey to identify perceived barriers to their implementation. We describe the benefits of model-based designs (flexibility, superior operating characteristics, extended scope), their current uptake, and existing resources. The most prominent barriers to implementation of a model-based design were lack of suitable training, chief investigators' preference for algorithm-based designs (e.g., 3+3), and limited resources for study design before funding. We use a real-world example to illustrate how these barriers can be overcome. There is overwhelming evidence for the benefits of CRM. Many leading pharmaceutical companies routinely implement model-based designs. Our analysis identified barriers for academic statisticians and clinical academics in mirroring the progress industry has made in trial design. Unified support from funders, regulators, and journal editors could result in more accurate doses for later-phase testing, and increase the efficiency and success of clinical drug development. We give recommendations for increasing the uptake of model-based designs for dose-finding trials in academia.

  18. Designing Network-based Business Model Ontology

    DEFF Research Database (Denmark)

    Hashemi Nekoo, Ali Reza; Ashourizadeh, Shayegheh; Zarei, Behrouz

    2015-01-01

    Survival on dynamic environment is not achieved without a map. Scanning and monitoring of the market show business models as a fruitful tool. But scholars believe that old-fashioned business models are dead; as they are not included the effect of internet and network in themselves. This paper...... is going to propose e-business model ontology from the network point of view and its application in real world. The suggested ontology for network-based businesses is composed of individuals` characteristics and what kind of resources they own. also, their connections and pre-conceptions of connections...... such as shared-mental model and trust. However, it mostly covers previous business model elements. To confirm the applicability of this ontology, it has been implemented in business angel network and showed how it works....

  19. Using Mathematical Modeling and Set-Based Design Principles to Recommend an Existing CVL Design

    Science.gov (United States)

    2017-09-01

    MATHEMATICAL MODELING AND SET-BASED DESIGN PRINCIPLES TO RECOMMEND AN EXISTING CVL DESIGN by William H. Ehlies September 2017 Thesis Advisor...Office of Management and Budget, Paperwork Reduction Project (0704-0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE...September 2017 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE USING MATHEMATICAL MODELING AND SET-BASED DESIGN PRINCIPLES

  20. Model based design of electronic throttle control

    Science.gov (United States)

    Cherian, Fenin; Ranjan, Ashish; Bhowmick, Pathikrit; Rammohan, A.

    2017-11-01

    With the advent of torque based Engine Management Systems, the precise control and robust performance of the throttle body becomes a key factor in the overall performance of the vehicle. Electronic Throttle Control provides benefits such as improved air-fuel ratio for improving the vehicle performance and lower exhausts emissions to meet the stringent emission norms. Modern vehicles facilitate various features such as Cruise Control, Traction Control, Electronic Stability Program and Pre-crash systems. These systems require control over engine power without driver intervention, which is not possible with conventional mechanical throttle system. Thus these systems are integrated to function with the electronic throttle control. However, due to inherent non-linearities in the throttle body, the control becomes a difficult task. In order to eliminate the influence of this hysteresis at the initial operation of the butterfly valve, a control to compensate the shortage must be added to the duty required for starting throttle operation when the initial operation is detected. Therefore, a lot of work is being done in this field to incorporate the various nonlinearities to achieve robust control. In our present work, the ETB was tested to verify the working of the system. Calibration of the TPS sensors was carried out in order to acquire accurate throttle opening angle. The response of the calibrated system was then plotted against a step input signal. A linear model of the ETB was prepared using Simulink and its response was compared with the experimental data to find out the initial deviation of the model from the actual system. To reduce this deviation, non-linearities from existing literature were introduced to the system and a response analysis was performed to check the deviation from the actual system. Based on this investigation, an introduction of a new nonlinearity parameter can be used in future to reduce the deviation further making the control of the ETB more

  1. Yeast-based biosensors: design and applications.

    Science.gov (United States)

    Adeniran, Adebola; Sherer, Michael; Tyo, Keith E J

    2015-02-01

    Yeast-based biosensing (YBB) is an exciting research area, as many studies have demonstrated the use of yeasts to accurately detect specific molecules. Biosensors incorporating various yeasts have been reported to detect an incredibly large range of molecules including but not limited to odorants, metals, intracellular metabolites, carcinogens, lactate, alcohols, and sugars. We review the detection strategies available for different types of analytes, as well as the wide range of output methods that have been incorporated with yeast biosensors. We group biosensors into two categories: those that are dependent upon transcription of a gene to report the detection of a desired molecule and those that are independent of this reporting mechanism. Transcription-dependent biosensors frequently depend on heterologous expression of sensing elements from non-yeast organisms, a strategy that has greatly expanded the range of molecules available for detection by YBBs. Transcription-independent biosensors circumvent the problem of sensing difficult-to-detect analytes by instead relying on yeast metabolism to generate easily detected molecules when the analyte is present. The use of yeast as the sensing element in biosensors has proven to be successful and continues to hold great promise for a variety of applications. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permission@oup.com.

  2. Multi performance option in direct displacement based design

    Directory of Open Access Journals (Sweden)

    Muljati Ima

    2017-01-01

    Full Text Available Compare to traditional method, direct displacement based design (DDBD offers the more rational design choice due to its compatibility with performance based design which is controlled by the targeted displacement in design. The objectives of this study are: 1 to explore the performance of DDBD for design Level-1, -2 and -3; 2 to determine the most appropriate design level based on material efficiency and damage risk; and 3 to verify the chosen design in order to check its performance under small-, moderate- and severe earthquake. As case study, it uses regular concrete frame structures consists of fourand eight-story with typical plan, located in low- and high-risk seismicity area. The study shows that design Level-2 (repairable damage is the most appropriate choice. Nonlinear time history analysis is run for each case study in order to verify their performance based on parameter: story drift, damage indices, and plastic mechanism. It can be concluded that DDBD performed very well in predicting seismic demand of the observed structures. Design Level-2 can be chosen as the most appropriate design level. Structures are in safe plastic mechanism under all level of seismicity although some plastic hinges formed at some unexpected locations.

  3. On HTML and XML based web design and implementation techniques

    International Nuclear Information System (INIS)

    Bezboruah, B.; Kalita, M.

    2006-05-01

    Web implementation is truly a multidisciplinary field with influences from programming, choosing of scripting languages, graphic design, user interface design, and database design. The challenge of a Web designer/implementer is his ability to create an attractive and informative Web. To work with the universal framework and link diagrams from the design process as well as the Web specifications and domain information, it is essential to create Hypertext Markup Language (HTML) or other software and multimedia to accomplish the Web's objective. In this article we will discuss Web design standards and the techniques involved in Web implementation based on HTML and Extensible Markup Language (XML). We will also discuss the advantages and disadvantages of HTML over its successor XML in designing and implementing a Web. We have developed two Web pages, one utilizing the features of HTML and the other based on the features of XML to carry out the present investigation. (author)

  4. A Representation System User Interface for Knowledge Base Designers

    OpenAIRE

    Fikes, Richard E.

    1982-01-01

    A major strength of frame-based knowledge representation languages is their ability to provide the knowledge base designer with a concise and intuitively appealing means expression. The claim of intuitive appeal is based on the observation that the object -centered style of description provided by these languages often closely matches a designer's understanding of the domain being modeled and therefore lessens the burden of reformulation involved in developing a formal description. To be effe...

  5. Model based process-product design and analysis

    DEFF Research Database (Denmark)

    Gani, Rafiqul

    This paper gives a perspective on modelling and the important role it has within product-process design and analysis. Different modelling issues related to development and application of systematic model-based solution approaches for product-process design is discussed and the need for a hybrid...... model-based framework is highlighted. This framework should be able to manage knowledge-data, models, and associated methods and tools integrated with design work-flows and data-flows for specific product-process design problems. In particular, the framework needs to manage models of different types......, forms and complexity, together with their associated parameters. An example of a model-based system for design of chemicals based formulated products is also given....

  6. Internet based remote cooperative engineering system for NSSS system design

    International Nuclear Information System (INIS)

    Kim, Y. S.; Lee, S. L.

    2000-01-01

    Implementation of information technology system through the nuclear power plant life cycle which covers site selection, design, construction, operation and decommission has been suggested continually by the reports or guidelines from NIRMA, INPO, NUMARC, USNRC and EPRI since late 1980's, and some of it has been actually implemented and applied partially to the practical design process. However, for the NSSS system design, a high level activity of nuclear power plant design phase, none of the effects has been reported with regard to implementing the information system. In Korea, KAERI studied NuIDEAS(Nuclear Integrated Database and Design Advancement System) in 1995, and KAERI (Korea Electric Power Research Institute) worked with CENP (Combustion Engineering Nuclear Power) for KNGR IMS(Information Management System) in 1997 as trials to adopt information system for NSSS system design. In this paper, after reviewing the pre-studied two information system, we introduce implementation of the information system for NSSS system design which is compatible with the on-going design works and can be used as means of concurrent engineering through internet. With this electronic design system, we expect increase of the design efficiency and productivity by switching from hard copy based design flow to internet based system. In addition, reliability and traceability of the design data is highly elevated by containing the native document file together with all the review, comment and resolution history in one database

  7. Evaluation of the directional dose equivalent H,(0.07) for ring dosemeters

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Tovar M, V.M.

    2006-01-01

    The personnel dosimetry laboratory (LDP) of the Metrology department received an user's of radiation beta application that incidentally had irradiated 14 couples of ring dosemeters for extremities of the type TLD-100 given by the LDP. This sample of 14 couples of rings tentatively it was irradiated in the months of July-August of the year 2004, and he requested in an expedite way the evaluation of the received dose equivalent. The LSCD builds two calibration curves in terms of the directional dose equivalent H'(0.07) using two sources patterns of 90 Sr- 90 Y for beta radiation: one of 74 MBq and another of 1850 MBq with traceability to the PTB. The first curve in the interval of 0 to 5 mSv, the second in the range of 5 to 50 mSv, taking into account effects by positioned of the rings in the phantom. Both calibration curves were validated by adjustment lack, symmetry of residuals and normality of the same ones. It is evaluated and analyzing the H'(0.007) for these 14 couples of rings using the Tukey test of media of a single road. It was found that the H , its could be classified in 4 groups, and that the probability that its has irradiated in a random way it was smaller to the level at α = 0.05. (Author)

  8. Examination of the long-term stability of radiation survey meters and electronic pocket dosemeters

    International Nuclear Information System (INIS)

    Chida, K.; Nishimura, Y.; Sato, Y.; Endo, A.; Sakamoto, M.; Hoshi, C.; Zuguchi, M.

    2008-01-01

    To describe the stability of radiation survey meters (RSMs) and electronic pocket dosemeters (EPDs), we examined 28 EPDs and 24 RSMs: 12 used NaI(Tl) scintillation RSMs and 12 used Geiger-Muller (GM) RSMs. We used simple methods for the relative calibration of the 24 RSMs and 28 EPDs. The RSM and EPD measurements were compared with a calibrated RSM and EPD (reference: traceable from the national standard of exposure) using a homemade measurement device to maintain the reproducibility of the measurements with reference radiation sources (i.e. 137 Cs, 90 Sr and 67 Ga). The response of RSMs and EPDs, especially after prolonged use, should be checked periodically. In particular, GMRSMs that have been in use for many years have very low sensitivity and poor reproducibility. Our simple method for the relative calibration of RSMs and EPDs was shown to be effective for quality assurance purposes in checking RSMs and EPDs. We recommend regular checks and calibration for sustained performance of RSMs and EPDs. (authors)

  9. The effect of radiation on bioluminescent bacteria: possible use of luminescent bacteria as a biological dosemeter

    International Nuclear Information System (INIS)

    Mantel, J.; Freidin, M.; Perry, H.

    1983-01-01

    The purpose of the study was to investigate the response of the bioluminescent Photobacterium phosphoreum to radiation, and the possible use of the bacteria as a biological radiation dosemeter, i.e. a water-equivalent biological system that will compare beams not merely on the basis of absorbed dose, but also have intrinsic RBE values for different radiation beams. Samples were irradiated by a 12 MeV electron beam at a dose rate of 3.0 Gy min -1 , by 60 Co gamma rays at 2.85 Gy min -1 , and by 100 kVsub(p) x-rays at a dose rate of 2.13 Gy min -1 . To study dose-rate dependence, the survival fraction was obtained for a 12 MeV electron beam at 0.50 and 12 Gy min -1 for 20.0 Gy. The survival fraction proved to be independent of dose rate in this range. The results presented in this work indicate that by using bioluminescent bacteria, RBE measurements can be markedly simplified and the results interpreted unequivocally. (U.K.)

  10. CHARACTERIZATION OF A THIN SILICON SENSOR FOR ACTIVE NEUTRON PERSONAL DOSEMETERS.

    Science.gov (United States)

    Takada, M; Nunomiya, T; Nakamura, T; Matsumoto, T; Masuda, A

    2016-09-01

    A thin silicon sensor has been developed for active neutron personal dosemeters for use by aircrews and first responders. This thin silicon sensor is not affected by the funneling effect, which causes detection of cosmic protons and over-response to cosmic neutrons. There are several advantages to the thin silicon sensor: a decrease in sensitivity to gamma rays, an improvement of the energy detection limit for neutrons down to 0.8 MeV and an increase in the sensitivity to fast neutrons. Neutron response functions were experimentally obtained using 2.5 and 5 MeV monoenergy neutron beams and a (252)Cf neutron source. Simulation results using the Monte Carlo N-Particle transport code agree quite well with the experimental ones when an energy deposition region shaped like a circular truncated cone is used in place of a cylindrical region. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Investigations of the luminescence of phosphate glasses with respect to their application as solid dosemeters

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1977-03-01

    A comprehensive presentation of the luminescent properties of phosphate glass is worked out. The extensive investigations show an essential enlargement of the knowledge on the luminescence of phosphate glass existing hitherto. These results form the basis for a detailed discussion of the luminescence mechanism. By applying additional results of measurements concerning optical and paramagnetic absorption, enabling the access to the atomic effect, propositions were developed for models of absorption, excitation and luminous centers relevant for dosimetry for which Ag ++ was found to be the constituent determining the centers. The interpretation of the luminescence phenomena within the frame of these models leads to considerable corrections on the existing concepts. At the same time the comparability of Ag-doped phosphate glasses and alkali halogenides is shown with respect to their luminescence behaviour, and with it an argument for the existence of crystal-like short-order regions in the amorphous glass is provided. This result serves as a basis for a discussion of the centers in the band model. Further investigations dealt with the quantities of influence for the practical application of the dosemeter. By interpretation of these results explanations are given for the effect of irradiation and evaluation temperatures, of LET, the dose, and UV light on the measuring signal. The phenomenon of 'pre-dose', for which especially surface effects have been detected as cause, is discussed under the aspect of a boundary layer theory. (orig./HP) [de

  12. Environmental gamma-ray dose measurements with thermoluminescence dosemeters (TLD) and environmental radiation characteristics

    International Nuclear Information System (INIS)

    Kanematsu, Seiko

    1999-01-01

    It is important to evaluate environmental gamma-ray exposure both at work and home in order to assess people's collective dosages. Environmental gamma radiation was measured for air-absorbed dose with a thermoluminescence dosemeter at various points in the workplace and Ningyotoge, and workplace radiation characteristics were analyzed. From the results, the public dose due to gamma rays generated artificially was assessed to be sufficiently lower than the annual limit. For indoor environments of the workplace, the maximum dosage rate among measured values was 97 nGy/h and the minimum value was 70 nGy/h, the average over one year was 83 nGy/h. The average annual outdoor dosage for a year was 82 nGy/ h. In Ningyotoge, the maximum was 103 nGy/h, minimum 60 nGy/h, and average 88 nGy/h. These values depend on the nature of the soil and weather factors, showing higher values in the summer than in the winter in the workplace. There was no significant difference in the dosage rate in houses and the workplace. (author)

  13. Kinetics of light sum collection in solid dosemeters with several trapping levels

    International Nuclear Information System (INIS)

    Vlasov, V.K.; Tarasov, M.Yu.

    1983-01-01

    On the basis of a stochastic model of filling up the electron-hole capture centres following irradiation, the kinetics of light sum accumulation in crystallophosphors with any number of capture levels has been considered. Using as an example a crystallophosphor with two hole- and two electron capture centres, solution of equations for the kinetics of light sum accumulation in solid dosemeters is presented. It is shown that in the presence of two competing capture centres the filling-up of one of the traps is always described by the function with a bent and superlinear section, whereas the filling-up of the competing trap is described by the function without a bent. The dose-effect functional relationship for competing traps does not depend either on the energetic depth of the trap or absolute values of capture micro cross-sections, but depends solely on relative values of macro- and micro cross-sections for competing traps. The theoretical model has been checked when studying radiothermoluminescence of synthetic quartz. The experimental results are shown to agree well with the model suggested

  14. Measurement of indoor radon Concentrations in Osaka, Nara, Wakayama and Hyogo with passive dosemeters

    International Nuclear Information System (INIS)

    Mori, Toshiaki; Hori, Yasuharu; Takeda, Atsuhiko; Iwasaki, Tamiko; Uchiyama, Masahumi; Fujimoto, Kenzo; Kankura, Takako; Kobayashi, Sadayosi.

    1989-01-01

    Indoor radon concentrations of 792 houses in Osaka, Nara, Wakayama and Hyogo were measured by the passive dosemeter which was developed in Karlsruhe Nuclear Research Center in West Germany. Each house was measured at two places for successive two periods of six months to obtain annual average exposure due to radon daughters. The arithmetic mean concentration of all houses was 45.2 Bq/m 3 with a standard deviation of 27.2; the geometric mean, 40.7 Bq/m 3 and the median, 39 Bq/m 3 . The distribution of the radon levels was approximately log-normal with 80% of houses having radon concentrations less than 60 Bq/m 3 . The seasonal variation of the mean radon concentration was evident between the former period including winter value of 45 Bq/m 3 and the latter including summer value of 32 Bq/m 3 . The indoor radon concentrations of wooden houses were found to have the widest distribution with the highest value of 371 Bq/m 3 . The highest value obtained in the ferro-concrete house was 118 Bq/m 3 . Twelve houses having indoor radon concentrations higher than 120 Bq/m 3 were all Japanese traditional wooden houses with walls made of soil. (author)

  15. Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter

    International Nuclear Information System (INIS)

    Preciado-Flores, S.; Schreck, M.; Melendrez, R.; Chernov, V.; Bernal, R.; Cruz-Vazquez, C.; Cruz-Zaragoza, E.; Barboza-Flores, M.

    2006-01-01

    Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 μm thick CVD diamond (polycrystalline diamond films prepared by chemical vapor deposition) film were studied in order to test its performance as a beta radiation dosemeter. The TL response is composed of four main TL glow peaks; two of these are in the range of 150-200 deg. C and two additional peaks in the 250-400 deg. C temperature range. The integrated TL as a function of radiation dose is linear up to 100 Gy and increases with increasing dose exposure. The dose dependence of the integrated OSL exhibits a similar behavior. The observed OSL/TL behavior for the CVD diamond film clearly demonstrate its capability for applications in radiation dosimetry with special relevance in medical dosimetry owing to the diamond's intrinsic material properties. (authors)

  16. On optically stimulated luminescence properties of household salt as a retrospective dosemeter

    International Nuclear Information System (INIS)

    Timar-Gabor, A.; Trandafir, O.

    2013-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) in the UV (270-370 nm) spectral region have been investigated for five types of table salt (NaCl) available in Romanian supermarkets with a view to applying them in retrospective dosimetry. The salt samples gave bright TL signals with two main peaks at ∼ 100 deg. C and at 300 or 260 deg. C, depending on the origin of the salt and bright OSL signals under continuous stimulation with blue light. The OSL signal (stimulated at 100 deg. C after a pre-heat of 10 s at 150 deg. C) was used for investigations in a standard multiple aliquot procedure. The dose- response was found to be linear in the dose range investigated (up to ∼ 100 mGy) and the lower limit of detection for the samples varied from ∼ 0.01 to 14 mGy. These characteristics, along with the widespread abundance and low cost of household salt, confirm its potential as a retrospective dosemeter. (authors)

  17. Thermoluminescent and optical processes in alkaline halogenides dosemeters contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.; Melendrez, R.; Castaneda, B.; Pedroza M, M.; Chernov, V.; Perez S, R.; Aceves, R.

    2000-01-01

    Recent research results are presented about the properties of the optical processes of photo transferred thermoluminescence (TLFT), optical whitening (BO), thermoluminescence induced by light (TLL) and its effect in the thermoluminescent curve (Tl) produced by ionizing and non-ionizing radiation. The systematic analysis of all these processes, acquires a singular importance due that actually the alkaline halogenide crystals are object of intense investigations which analyse their potential applications as detectors and radiation dosemeters through stimulated optical luminescence techniques or thermoluminescence. The obtained data show that the Tl curve of material with this nature can be enormously affected by exposure of phosphorus to the environmental light or UV. This is in part due to liberation processes of charge bearers are shouted and makes a subsequent trapping in less temperature traps; at the same time that induce changes in the intensity of determined Tl bands. Additionally, also it is observed that mentioned phenomena are related as with wavelength of incident light as of the illumination time. Finally, the obtained information allows to conclude that although the illumination effect is extremely complex, it is associated and can be explained mainly with phenomena that implicate the electrons excitation trapped in form of F centers and trapping mechanisms or radioactive and non-radioactive recombination. (Author)

  18. Assessment of diagnostic multileaf collimator for cephalometric exposure reduction using optically stimulated luminescent dosemeters

    International Nuclear Information System (INIS)

    Han, Su Chul; Kim, Kum Bae; Jung, Haijo; Ji, YoungHoon; Park, Seungwoo

    2017-01-01

    A diagnostic multileaf collimator (MLC) was developed for diagnostic radiography dose reduction. Optically stimulated luminescent dosemeters (OSLDs) were used to evaluate the efficacy of this device for dental radiography cephalometric exposure reduction. The OSLD dosimetric characteristics for 80 kVp cephalometric exposure were first obtained. The batch homogeneity and reproducibility were 1.67 % and 0.18-1.58, respectively. Good linearity was obtained between the OSLD dose and response, and the angular dependence was within ±4 %. The equivalent organ doses for the left eye, right eye and thyroid were 41.20±6.58, 178.86±1.71 and 171.12±8.78 mSv and 36.80±0.33, 156.63±0.22 and 22.04±0.13 mSv for the open and MLC fields, respectively. The MLC-induced dose reductions for the left and right eyes of in field were 10.67±16.78 and 12.42±8.84 %, respectively, and that of the thyroid gland of out of field was 87±8.82 %, considering combined uncertainty. Therefore, use of diagnostic MLC for dose reduction during dental radiography cephalometric exposure is both feasible and effective. (authors)

  19. Thermoluminescent dosemeters for determining the energy absorbed during X-ray radiography of the vertebral column

    International Nuclear Information System (INIS)

    Liebl, R.

    1983-01-01

    The dose and absorbed energy during normal diagnostic X-ray of various sections of the vertebral column were determined with LiF-dosemeters in a phantom. The paper describes a method to be used to determine integral doses from the dose measurements. The energy absorbed for one X-ray picture of the vertebral column is between 5 and 30 mJ. Compared to other diagnostical X-rays the quantity of the energy absorbed during X-ray of the vertebral column is rather high and is only reached by X-rays in the pelvic region. The speculations on the rate of incidence of malignent neoplasms on the basis of diagnostical X-ray of the vertebral column reveal a value of 50 per 60 x 10 6 persons. This value is likely to overestimate the risk, seems, however, to be low in comparison to other risks of every day life (traffic accident, mountainering, etc). (orig./HP) [de

  20. Design of Test Wrapper Scan Chain Based on Differential Evolution

    Directory of Open Access Journals (Sweden)

    Aijun Zhu

    2013-08-01

    Full Text Available Integrated Circuit has entered the era of design of the IP-based SoC (System on Chip, which makes the IP core reuse become a key issue. SoC test wrapper design for scan chain is a NP Hard problem, we propose an algorithm based on Differential Evolution (DE to design wrapper scan chain. Through group’s mutation, crossover and selection operations, the design of test wrapper scan chain is achieved. Experimental verification is carried out according to the international standard benchmark ITC’02. The results show that the algorithm can obtain shorter longest wrapper scan chains, compared with other algorithms.

  1. Knowledge-based support system for requirement elaboration in design

    International Nuclear Information System (INIS)

    Furuta, Kazuo; Kondo, Shunsuke

    1994-01-01

    Design requirements are the seeds of every design activity, but elicitation and formalization of them are not easy tasks. This paper proposes a method to support designers in such requirement elaboration process with a computer. In this method the cognitive work space of designers is modeled by abstraction and structural hierarchies, and supporting functions of knowledge-based requirement elaboration, requirement classification and assessment of contentment status of requirements are provided on this framework. A prototype system was developed and tested using fast breeder reactor design. (author)

  2. Probability based load combinations for design of category I structures

    International Nuclear Information System (INIS)

    Reich, M.; Hwang, H.

    1985-01-01

    This paper discusses a reliability analysis method and a procedure for developing the load combination design criteria for category I structures. For safety evaluation of category I concrete structures under various static and dynamic loads, a probability-based reliability analysis method has been developed. This reliability analysis method is also used as a tool for determining the load factors for design of category I structures. In this paper, the load combinations for design of concrete containments, corresponding to a target limit state probability of 1.0 x 10 -6 in 4 years, are described. A comparison of containments designed using the ASME code and the proposed design criteria is also presented

  3. Designing Android Based Augmented Reality Location-Based Service Application

    Directory of Open Access Journals (Sweden)

    Alim Hardiansyah

    2018-01-01

    Full Text Available Android is an operating system for Linux based smartphone. Android provides an open platform for the developers to create their own application. The most developed and used application now is location based application. This application gives personalization service for mobile device user and is customized to their location. Location based service also gives an opportunity for the developers to develop and increase the value of service. One of the technologies that could be combined with location based application is augmented reality. Augmented reality combines the virtual world with the real one. By the assistance of augmented reality, our surrounding environment could interact in digital form. Information of objects and environment surround us could be added to the augmented reality system and presented. Based on the background, the writers tried to implement those technologies on now rapidly developing android application as a final project to achieve bachelor degree in Department of Informatics Engineering, Faculty of Information Technology and Visual Communication, Al Kamal Science and Technology Institute. This application could be functioned to locate school by using location based service technology with the assistance of navigational applications such as waze and google maps, in form of live direction process through the smartphone

  4. Manufacturing system design based on axiomatic design: Case of assembly line

    Energy Technology Data Exchange (ETDEWEB)

    Hager, T.; Wafik, H.; Faouzi, M.

    2017-07-01

    In this paper, a combined Production Line Design (PLD) process which includes many design aspects is presented, developed and validated. Design/methodology/approach: The PLD process is based on the SADT (Structured Analysis and Design Technique) diagram and the Axiomatic Design (AD) method. Practical implications: For a purpose of validation, this proposed process has been applied in a manufacturing company and it has been validated by simulation. Findings: The results of the validation indicated that the production line designed by this process is outperformed the initial line of the company. Originality/value: Recently, the problems of production line design (PLD) have attracted the attention of many researchers. However, only a few studies have treated the PLD which includes all design aspects. In this work, a combined PLD process is presented. It should be noted that the proposed process is simple and effective.

  5. Manufacturing system design based on axiomatic design: Case of assembly line

    International Nuclear Information System (INIS)

    Hager, T.; Wafik, H.; Faouzi, M.

    2017-01-01

    In this paper, a combined Production Line Design (PLD) process which includes many design aspects is presented, developed and validated. Design/methodology/approach: The PLD process is based on the SADT (Structured Analysis and Design Technique) diagram and the Axiomatic Design (AD) method. Practical implications: For a purpose of validation, this proposed process has been applied in a manufacturing company and it has been validated by simulation. Findings: The results of the validation indicated that the production line designed by this process is outperformed the initial line of the company. Originality/value: Recently, the problems of production line design (PLD) have attracted the attention of many researchers. However, only a few studies have treated the PLD which includes all design aspects. In this work, a combined PLD process is presented. It should be noted that the proposed process is simple and effective.

  6. Guide for the realization of Design Base Documents (DBD)

    International Nuclear Information System (INIS)

    Roca Mallofre, G. la

    2010-01-01

    Guide for improving the consistency and quality content of the Design Base Documents. It's a short description of how to carry out and complete these Documents but focusing on those aspects that can be more confusing and harder to interpret. This guide aims to clarify the term Design Base distinguishing between production and safety, and it focuses on safety Design Base Documents and their values and references. It also emphasizes the difference between the support system and the interface system when there is a functional connection between different systems.

  7. Circuit Design of Surface Acoustic Wave Based Micro Force Sensor

    Directory of Open Access Journals (Sweden)

    Yuanyuan Li

    2014-01-01

    Full Text Available Pressure sensors are commonly used in industrial production and mechanical system. However, resistance strain, piezoresistive sensor, and ceramic capacitive pressure sensors possess limitations, especially in micro force measurement. A surface acoustic wave (SAW based micro force sensor is designed in this paper, which is based on the theories of wavelet transform, SAW detection, and pierce oscillator circuits. Using lithium niobate as the basal material, a mathematical model is established to analyze the frequency, and a peripheral circuit is designed to measure the micro force. The SAW based micro force sensor is tested to show the reasonable design of detection circuit and the stability of frequency and amplitude.

  8. Case-based reasoning support for engineering design

    Science.gov (United States)

    Lees, Brian; Hamza, Meer; Irgens, Chris

    2000-10-01

    The potential application of case-based reasoning (CBR) in design support is illustrated through examples drawn from research at the University of Paisley, demonstrating the suitability of CBR for different aspects of design, different problem areas, and different design goals. A quality advisory system has been developed for the early stages of mechanical engineering design, the aim of which is to provide quality advice in a variant design situation. In the domain of software engineering CBR has been applied to advise on which metrics are appropriate fora assessing the quality of the software currently under design. The system integrates CBR with concepts from quality function deployment (QFD) and incorporates a case library holding past software quality histories. CBR has been applied in support of conceptual design: to capture detailed design histories by monitoring designer actions, and thereby support design reuse through the evaluation of designs, through the provision of query, browsing and replay facilities. The resulting system is aimed to support the design of safety critical systems, by assisting in the construction of safety arguments, and cooperative design.

  9. Conceptual design of distillation-based hybrid separation processes.

    Science.gov (United States)

    Skiborowski, Mirko; Harwardt, Andreas; Marquardt, Wolfgang

    2013-01-01

    Hybrid separation processes combine different separation principles and constitute a promising design option for the separation of complex mixtures. Particularly, the integration of distillation with other unit operations can significantly improve the separation of close-boiling or azeotropic mixtures. Although the design of single-unit operations is well understood and supported by computational methods, the optimal design of flowsheets of hybrid separation processes is still a challenging task. The large number of operational and design degrees of freedom requires a systematic and optimization-based design approach. To this end, a structured approach, the so-called process synthesis framework, is proposed. This article reviews available computational methods for the conceptual design of distillation-based hybrid processes for the separation of liquid mixtures. Open problems are identified that must be addressed to finally establish a structured process synthesis framework for such processes.

  10. Transducers for Sound and Vibration - FEM Based Design

    DEFF Research Database (Denmark)

    Liu, Bin

    2001-01-01

    Design of transducers for measurement of vibration (piezoelectric accelerometers) and sound (condenser microphones) is a very labour intensive work. The design work is mostly based on experience and on simple analogies to electrical circuit design. Often a time consuming itterative loop is used......: Specification of the transducer, production of a physical prototype, measurements on the prototype, changed specification of the transducer etc. Furthermore are many transducers made based on customer requirements which also increases the amount of required design work. For these reasons there is a need...... for methods that can reduce the design time consumption and the number of itterations. The present work proposes to use finite element based programs for simulating the behaviour of a transducer with a given set of specifications. A simulation program for accelerometers was developed and has been tested...

  11. A supportive architecture for CFD-based design optimisation

    Science.gov (United States)

    Li, Ni; Su, Zeya; Bi, Zhuming; Tian, Chao; Ren, Zhiming; Gong, Guanghong

    2014-03-01

    Multi-disciplinary design optimisation (MDO) is one of critical methodologies to the implementation of enterprise systems (ES). MDO requiring the analysis of fluid dynamics raises a special challenge due to its extremely intensive computation. The rapid development of computational fluid dynamic (CFD) technique has caused a rise of its applications in various fields. Especially for the exterior designs of vehicles, CFD has become one of the three main design tools comparable to analytical approaches and wind tunnel experiments. CFD-based design optimisation is an effective way to achieve the desired performance under the given constraints. However, due to the complexity of CFD, integrating with CFD analysis in an intelligent optimisation algorithm is not straightforward. It is a challenge to solve a CFD-based design problem, which is usually with high dimensions, and multiple objectives and constraints. It is desirable to have an integrated architecture for CFD-based design optimisation. However, our review on existing works has found that very few researchers have studied on the assistive tools to facilitate CFD-based design optimisation. In the paper, a multi-layer architecture and a general procedure are proposed to integrate different CFD toolsets with intelligent optimisation algorithms, parallel computing technique and other techniques for efficient computation. In the proposed architecture, the integration is performed either at the code level or data level to fully utilise the capabilities of different assistive tools. Two intelligent algorithms are developed and embedded with parallel computing. These algorithms, together with the supportive architecture, lay a solid foundation for various applications of CFD-based design optimisation. To illustrate the effectiveness of the proposed architecture and algorithms, the case studies on aerodynamic shape design of a hypersonic cruising vehicle are provided, and the result has shown that the proposed architecture

  12. Design-Based Research for Professional Learning for "Cultural Mathematics"

    Science.gov (United States)

    Kravia, Geori; Owens, Kay

    2014-01-01

    Design-based research is being used to develop and refine the principles used in professional learning workshops with teachers from three different Papua New Guinean ecologies: highlands, coastal, and inland in a coastal province. The appropriateness of the design of principles for Papua New Guinean Elementary Schools is tried over several phases…

  13. Group-Based Life Design Counseling in an Italian Context

    Science.gov (United States)

    Di Fabio, Annamaria; Maree, Jacobus Gideon

    2012-01-01

    This study examined the effectiveness of group-based Life Design Counseling using the Career-Story Interview. Written exercises were used to implement the seven topics in the Career-Story Interview. The present study employed an experimental design that involved two groups of Italian entrepreneurs from the agricultural and trade sectors, namely an…

  14. Design and Construction Documents Associated with N232, Sustainability Base

    Science.gov (United States)

    Zornetzer, Steven F.; Schuler, Raymond F.; Grymes, Rosalind A.

    2014-01-01

    This request comprehensively covers documents associated with the design and construction of Sustainability Base, N232. The intent of this project specifically envisioned broad dissemination of these materials to others undertaking the design and construction of high-performing energy- and resource-efficient buildings in comparable climate zones.

  15. Designing Spreadsheet-Based Tasks for Purposeful Algebra

    Science.gov (United States)

    Ainley, Janet; Bills, Liz; Wilson, Kirsty

    2005-01-01

    We describe the design of a sequence of spreadsheet-based pedagogic tasks for the introduction of algebra in the early years of secondary schooling within the Purposeful Algebraic Activity project. This design combines two relatively novel features to bring a different perspective to research in the use of spreadsheets for the learning and…

  16. Reference task-based design of crisis management games

    NARCIS (Netherlands)

    Link, Daniel; Meesters, Kenny; Hellingrath, Bernd; van de Walle, B.A.; Hiltz, S.R.; Pfaff, M.S.; Plotnick, L.; Shih, P.C.

    Serious games are an effective tool for giving players a hands-on, immersive experience of crisis situations. To simplify the design of such games while ensuring their relevance, we propose a design method that is based on reference tasks. The feasibility of this approach is demonstrated by the

  17. Effectiveness of design-based learning in engineering education

    NARCIS (Netherlands)

    Gomez Puente, S.M.; Eijck, van M.W.; Jochems, W.M.G.

    2011-01-01

    Design-based learning (DBL) has been introduced as an educational concept at Eindhoven University of Technology (TU/e) in 1997, in which students work co-operatively and actively on multidisciplinary design tasks (Wijnen, 2000). Theoretically DBL is not well underpinned. It has been researched

  18. Design-based learning in classrooms using playful digital toolkits

    NARCIS (Netherlands)

    Scheltenaar, K.J.; van der Poel, J.E.C.; Bekker, Tilde

    2015-01-01

    The goal of this paper is to explore how to implement Design Based Learning (DBL) with digital toolkits to teach 21st century skills in (Dutch) schools. It describes the outcomes of a literature study and two design case studies in which such a DBL approach with digital toolkits was iteratively

  19. Preparing Instructional Designers for Game-Based Learning: Part 1

    Science.gov (United States)

    Hirumi, Atsusi; Appelman, Bob; Rieber, Lloyd; Van Eck, Richard

    2010-01-01

    Like many rapidly growing industries, advances in video game technology are far outpacing research on its design and effectiveness. Relatively little is understood about how to apply what we know about teaching and learning to optimize game-based learning. For the most part, instructional designers know little about game development and video game…

  20. Teaching Database Design with Constraint-Based Tutors

    Science.gov (United States)

    Mitrovic, Antonija; Suraweera, Pramuditha

    2016-01-01

    Design tasks are difficult to teach, due to large, unstructured solution spaces, underspecified problems, non-existent problem solving algorithms and stopping criteria. In this paper, we comment on our approach to develop KERMIT, a constraint-based tutor that taught database design. In later work, we re-implemented KERMIT as EER-Tutor, and…

  1. Experiences with strain based limit state design in The Netherlands

    NARCIS (Netherlands)

    Gresnigt, A.M.; Foeken, R.J. van

    1996-01-01

    Limit state design differs from conventional design methods in that each failure mode is specifically addressed (e.g. burst, collapse, local buckling, fracture due to insufficient strain capacity of the pipe wall, fatigue). Based on an extensive theoretical and experimental research programme,

  2. Embedded Control System Design A Model Based Approach

    CERN Document Server

    Forrai, Alexandru

    2013-01-01

    Control system design is a challenging task for practicing engineers. It requires knowledge of different engineering fields, a good understanding of technical specifications and good communication skills. The current book introduces the reader into practical control system design, bridging  the gap between theory and practice.  The control design techniques presented in the book are all model based., considering the needs and possibilities of practicing engineers. Classical control design techniques are reviewed and methods are presented how to verify the robustness of the design. It is how the designed control algorithm can be implemented in real-time and tested, fulfilling different safety requirements. Good design practices and the systematic software development process are emphasized in the book according to the generic standard IEC61508. The book is mainly addressed to practicing control and embedded software engineers - working in research and development – as well as graduate students who are face...

  3. Agent-Based Coordination Model for Designing Transportation Applications

    OpenAIRE

    BADEIG, F; BALBO, F; SCEMAMA, G; ZARGAYOUNA, M

    2008-01-01

    This paper presents an environment-centered approach to design multi-agent solutions to transportation problems. Based on the Property-based Coordination Principle (PbC), the objective of our approach is to solve three recurrent issues in the design of these solutions: the knowledge problem, the space-time dimension and the dynamics of the real environment. To demonstrate the benefits of our approach, two completely different applications, a demand-responsive transportation system and a simul...

  4. Novel measurement-based indoor cellular radio system design

    OpenAIRE

    Aragón-Zavala, A

    2008-01-01

    A scaleable, measurement-based radio methodology has been created to use for the design, planing and optimisation of in door cellular radio systems. The development of this measurement-based methodology was performed having in mind that measurements are of ten required to valiate radio coverage in a building. Therefore, the concept of using care fully calibrated measurements to design and optimise a system is feasible since these measurements can easily be obtained prior to system deployment ...

  5. Computer-Aided Test Flow in Core-Based Design

    OpenAIRE

    Zivkovic, V.; Tangelder, R.J.W.T.; Kerkhoff, Hans G.

    2000-01-01

    This paper copes with the test-pattern generation and fault coverage determination in the core based design. The basic core-test strategy that one has to apply in the core-based design is stated in this work. A Computer-Aided Test (CAT) flow is proposed resulting in accurate fault coverage of embedded cores. The CAT now is applied to a few cores within the Philips Core Test Pilot IC project

  6. Research by Design: Design-Based Research and the Higher Degree Research student

    Science.gov (United States)

    Kennedy-Clark, Shannon

    2013-01-01

    Design-based research lends itself to educational research as the aim of this approach is to develop and refine the design of artefacts, tools and curriculum and to advance existing theory or develop new theories that can support and lead to a deepened understanding of learning. This paper provides an overview of the potential benefits of using a…

  7. Design for mood : Twenty activity-based opportunities to design for mood regulation

    NARCIS (Netherlands)

    Desmet, P.M.A.

    2015-01-01

    This paper introduces a theory-based approach to design for mood regulation. The main proposition is that design can best influence mood by enabling and stimulating people to engage in a broad range of mood-regulating activities. The first part of the manuscript reviews state-of-the art mood-focused

  8. Balancing Expression and Structure in Game Design: Developing Computational Participation Using Studio-Based Design Pedagogy

    Science.gov (United States)

    DeVane, Ben; Steward, Cody; Tran, Kelly M.

    2016-01-01

    This article reports on a project that used a game-creation tool to introduce middle-school students ages 10 to 13 to problem-solving strategies similar to those in computer science through the lens of studio-based design arts. Drawing on historic paradigms in design pedagogy and contemporary educational approaches in the digital arts to teach…

  9. Quasi-experimental designs in practice-based research settings: design and implementation considerations.

    Science.gov (United States)

    Handley, Margaret A; Schillinger, Dean; Shiboski, Stephen

    2011-01-01

    Although randomized controlled trials are often a gold standard for determining intervention effects, in the area of practice-based research (PBR), there are many situations in which individual randomization is not possible. Alternative approaches to evaluating interventions have received increased attention, particularly those that can retain elements of randomization such that they can be considered "controlled" trials. Methodological design elements and practical implementation considerations for two quasi-experimental design approaches that have considerable promise in PBR settings--the stepped-wedge design, and a variant of this design, a wait-list cross-over design, are presented along with a case study from a recent PBR intervention for patients with diabetes. PBR-relevant design features include: creation of a cohort over time that collects control data but allows all participants (clusters or patients) to receive the intervention; staggered introduction of clusters; multiple data collection points; and one-way cross-over into the intervention arm. Practical considerations include: randomization versus stratification, training run in phases; and extended time period for overall study completion. Several design features of practice based research studies can be adapted to local circumstances yet retain elements to improve methodological rigor. Studies that utilize these methods, such as the stepped-wedge design and the wait-list cross-over design, can increase the evidence base for controlled studies conducted within the complex environment of PBR.

  10. Designing and Evaluating Conative Game-Based Learning Scenarios

    DEFF Research Database (Denmark)

    Schønau-Fog, Henrik

    2014-01-01

    It is an essential prerequisite to design for motivation in game-based learning applications, tools and activities. However, how is it possible to design and evaluate motivational game-based learning scenarios in a systematic process-oriented manner based on conation and player engagement? While...... of ‘continuation desire’ such as interfacing with the scenario, exploration and socialising. This paper aims to combine the concepts of Player Engagement, Conation and Continuation Desire by focusing on the conative aspects which are the essential drivers for the desire to continue any learning activity......-based learning scenarios....

  11. Design Transformation based on Nature and Identity Formation in the Design of Landscape Elements

    Directory of Open Access Journals (Sweden)

    Zulkifli Muslim

    2016-01-01

    Full Text Available There is a lack of initiative from the designers to integrate the environmental resources in the material and design production of local urban landscape elements that reflects human culture and lifestyle. Based on criteria and principles of symbol design and transformation process, this paper describes the symbiotic relationship between local plants (flower and designs of landscape elements. Using visual analysis, the researcher manipulated shapes and forms of local plant images in producing possible shapes and forms for a design of landscape element (lamp post. The results indicate that the design transformation is a systematic process that allows for variations in design without losing the core characteristics and identity of the basic elements of nature.

  12. Reliability-Based Robust Design Optimization of Structures Considering Uncertainty in Design Variables

    Directory of Open Access Journals (Sweden)

    Shujuan Wang

    2015-01-01

    Full Text Available This paper investigates the structural design optimization to cover both the reliability and robustness under uncertainty in design variables. The main objective is to improve the efficiency of the optimization process. To address this problem, a hybrid reliability-based robust design optimization (RRDO method is proposed. Prior to the design optimization, the Sobol sensitivity analysis is used for selecting key design variables and providing response variance as well, resulting in significantly reduced computational complexity. The single-loop algorithm is employed to guarantee the structural reliability, allowing fast optimization process. In the case of robust design, the weighting factor balances the response performance and variance with respect to the uncertainty in design variables. The main contribution of this paper is that the proposed method applies the RRDO strategy with the usage of global approximation and the Sobol sensitivity analysis, leading to the reduced computational cost. A structural example is given to illustrate the performance of the proposed method.

  13. Design of learner-centred constructivism based learning process

    OpenAIRE

    Schreurs, Jeanne; Al-Huneidi, Ahmad

    2012-01-01

    A Learner-centered learning is constructivism based and Competence directed. We define general competencies, domain competencies and specific course competencies. Constructivism based learning activities are based on constructivism theory. For each course module the intended learning level will be defined. A model is built for the design of a learner centered constructivism based and competency directed learning process. The application of it in two courses are presented. Constructivism ba...

  14. Utilization of thermoluminescent dosemeters for determination of exposure or absorbed dose in a radiation gamma or X radiation field with unknown spectral distribution

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1981-06-01

    Having in view the choice of the best pair of dosemeters to be used in the 'Tandem' method, the main response characteristics of LiF:Mg, Ti, Li 2 B 4 O 7 :Mn, CaSO 4 Dy, CaF 2 :Mn and CaF 2 :Dy thermoluminescent dosemeters and also some critical parameters in their calibration and evaluation processes were studied. Three different physical forms of TLD's were investigated: hot pressed chips, disc teflon dosemeters and glass mini TLD's. Their calibration factors were obtained for the energy of Cobalt-60 gamma rays. Their energy dependences normalized to 60 Co radiation were determined using spectral width as parameter. 'Tandens' formed by all TLD's evaluated were compaired. (E.G.) [pt

  15. Effect of the energy dependence of response of neutron personal dosemeters routinely used in the UK on the accuracy of dose estimation

    CERN Document Server

    Tanner, R J; Thomas, D J

    2002-01-01

    A large set of neutron energy distributions have been classified by workplace to provide a guide to the neutron fields to which workers in particular industries are likely to be exposed. These have been combined (folded) with the results of a major programme of neutron personal dosemeter response function measurements, to provide results for the systematic errors that those dosemeters would give in workplaces. Data for neutron doses recorded for UK classified workers have been taken from the CIDI tables, and related to the results from the folding process. It has hence been possible to draw conclusions about the probable systematic errors that result from the use of the currently available neutron personal dosemeters, which have inherent problems associated with their energy dependence of response.

  16. Effect of the energy dependence of response of neutron personal dosemeters routinely used in the UK on the accuracy of dose estimation

    International Nuclear Information System (INIS)

    Tanner, R.J.; Thomas, D.J.; Bartlett, D.T.

    2002-01-01

    A large set of neutron energy distributions have been classified by workplace to provide a guide to the neutron fields to which workers in particular industries are likely to be exposed. These have been combined (folded) with the results of a major programme of neutron personal dosemeter response function measurements, to provide results for the systematic errors that those dosemeters would give in workplaces. Data for neutron doses recorded for UK classified workers have been taken from the CIDI tables, and related to the results from the folding process. It has hence been possible to draw conclusions about the probable systematic errors that result from the use of the currently available neutron personal dosemeters, which have inherent problems associated with their energy dependence of response. (author)

  17. Computer-based Creativity Enhanced Conceptual Design Model for Non-routine Design of Mechanical Systems

    Institute of Scientific and Technical Information of China (English)

    LI Yutong; WANG Yuxin; DUFFY Alex H B

    2014-01-01

    Computer-based conceptual design for routine design has made great strides, yet non-routine design has not been given due attention, and it is still poorly automated. Considering that the function-behavior-structure(FBS) model is widely used for modeling the conceptual design process, a computer-based creativity enhanced conceptual design model(CECD) for non-routine design of mechanical systems is presented. In the model, the leaf functions in the FBS model are decomposed into and represented with fine-grain basic operation actions(BOA), and the corresponding BOA set in the function domain is then constructed. Choosing building blocks from the database, and expressing their multiple functions with BOAs, the BOA set in the structure domain is formed. Through rule-based dynamic partition of the BOA set in the function domain, many variants of regenerated functional schemes are generated. For enhancing the capability to introduce new design variables into the conceptual design process, and dig out more innovative physical structure schemes, the indirect function-structure matching strategy based on reconstructing the combined structure schemes is adopted. By adjusting the tightness of the partition rules and the granularity of the divided BOA subsets, and making full use of the main function and secondary functions of each basic structure in the process of reconstructing of the physical structures, new design variables and variants are introduced into the physical structure scheme reconstructing process, and a great number of simpler physical structure schemes to accomplish the overall function organically are figured out. The creativity enhanced conceptual design model presented has a dominant capability in introducing new deign variables in function domain and digging out simpler physical structures to accomplish the overall function, therefore it can be utilized to solve non-routine conceptual design problem.

  18. Computer-based creativity enhanced conceptual design model for non-routine design of mechanical systems

    Science.gov (United States)

    Li, Yutong; Wang, Yuxin; Duffy, Alex H. B.

    2014-11-01

    Computer-based conceptual design for routine design has made great strides, yet non-routine design has not been given due attention, and it is still poorly automated. Considering that the function-behavior-structure(FBS) model is widely used for modeling the conceptual design process, a computer-based creativity enhanced conceptual design model(CECD) for non-routine design of mechanical systems is presented. In the model, the leaf functions in the FBS model are decomposed into and represented with fine-grain basic operation actions(BOA), and the corresponding BOA set in the function domain is then constructed. Choosing building blocks from the database, and expressing their multiple functions with BOAs, the BOA set in the structure domain is formed. Through rule-based dynamic partition of the BOA set in the function domain, many variants of regenerated functional schemes are generated. For enhancing the capability to introduce new design variables into the conceptual design process, and dig out more innovative physical structure schemes, the indirect function-structure matching strategy based on reconstructing the combined structure schemes is adopted. By adjusting the tightness of the partition rules and the granularity of the divided BOA subsets, and making full use of the main function and secondary functions of each basic structure in the process of reconstructing of the physical structures, new design variables and variants are introduced into the physical structure scheme reconstructing process, and a great number of simpler physical structure schemes to accomplish the overall function organically are figured out. The creativity enhanced conceptual design model presented has a dominant capability in introducing new deign variables in function domain and digging out simpler physical structures to accomplish the overall function, therefore it can be utilized to solve non-routine conceptual design problem.

  19. Knowledge representation and knowledge base design for operator advisor system

    International Nuclear Information System (INIS)

    Hangos, K.M.; Sziano, T.; Tapolcai, L.

    1990-01-01

    The problems of knowledge representation, knowledge base handling and design has been described for an Operator Advisor System in the Paks Nuclear Power Plant. The Operator Advisor System is to be implemented as a part of the 5th and 6th unit. The knowledge of the Operator Advisor system is described by a few elementary knowledge items (diagnostic event functions, fault graph, action trees), weighted directed graphs have been found as their common structure. List-type and relational representation of these graphs have been used for the on-line and off-line part of the knowledge base respectively. A uniform data base design and handling has been proposed which consists of a design system, a knowledge base editor and a knowledge base compiler

  20. Design of an intelligent materials data base for the IFR

    International Nuclear Information System (INIS)

    Mikaili, R.; Lambert, J.D.B.; Orth, T.D.

    1992-01-01

    In the development of the integral fast reactor (IFR) concept, there is a consensus that materials considerations are an important part of the reactor design, operation, and maintenance and that materials performance is central to liquid-metal reactor reliability and safety. In the design of the IRF materials data base, artificial intelligence techniques are being used to ensure efficient control of information. Intelligent control will provide for the selection of menus to be displayed, efficient data-base searches, and application-dependent guidance through the data base. The development of the IRF data base has progressed to the point of (a) completing the design of the data-base architecture and tables, (b) installing computer hardware for storing large amounts of data, (c) outlining strategies for data transferal, and (d) identifying ways to validate and secure the integrity of data