WorldWideScience

Sample records for dose dosis controlable

  1. Controllable dose; Dosis controlable

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T; Anaya M, R A [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2004-07-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  2. Dose. Detriment. Limit assessment; Dosis. Schadensmass. Grenzwertsetzung

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, J. [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS)

    2015-07-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  3. Control and monitoring of doses to patients in a team of digital mammography; Control y seguimiento de las dosis a pacientes en un equipo de mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Agulla Otero, M.; Torres Cabrera, R.; Hernando Gonzalez, I.

    2013-07-01

    In recent years is widespread use of imaging devices digital mammography. One of the advantages associated with this scanning is the ability to access a large amount of information contained in the headwaters of own digital images. The exploitation of this information allows the calculation of doses received by patients. This paper describes the methodology employed for this purpose and are presented the results of the control and monitoring of doses given in a digital mammography equipment. (Author)

  4. Estimation of dose rate around the spent control rods of a BWR; Estimacion de la rapidez de dosis alrededor de las barras de control gastadas de un BWR

    Energy Technology Data Exchange (ETDEWEB)

    Cancino P, G.

    2016-10-01

    The energy can come from fossil renewable sources (solar (natural gas, oil), wind, hydro, tidal, geothermal, biomass, bio energy and nuclear. Nuclear power can be obtained by fission reactions and fusion (still under investigation) atomic nuclei. Fission, is a partition of a very heavy nucleus (Uranium 235, for example) into two lighter nuclei. Much of the world's electric power is generated from the energy released by fission processes. In a nuclear power reactor, light water as the BWR, there are many important elements that allow safe driving operation, one of them are the elements or control systems, the burnable poison or neutron absorber inherently allow control power reactor. The control rods, which consist mostly of stainless steel and absorbing elements (such as boron carbide, hafnium, cadmium, among others) of thermal neutrons is able to initiate, regulate or stop the reactor power. These, due to the use of depleted burned or absorbing material and therefore reach their lifespan, which can be 15 years or have other values depending on the manufacturer. Control rods worn should be removed, stored or confined in expressly places. Precisely at this stage arises the importance of knowing their radiological condition to manipulate safely and without incident to the people health responsible for conducting these proceedings state arises. This thesis consists in the estimation of the dose rate in spent control rod made of boron carbide, from a typical BWR reactor. It will be estimated by direct radiation measurements with measurement equipment for radiotherapy ionization chamber, in six spent control rods, which were taken at different reactor operating cycles and are in a spent fuel pool. Using bracket electromechanical and electronic equipment for positioning and lifting equipment for radiation measurement around the control rod in the axial and radial arrangement for proper scanning. Finally will be presented a graphic corresponding to the dose

  5. Development of DosiMap: dosimetry device for radiotherapy quality assurance; Developpement du DosiMap: instrument de dosimetrie pour le controle qualite en radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Frelin, A M

    2006-10-15

    This thesis deals with the development of a new dosimetry device for the control of radiotherapy beams. This device is composed of a plane plastic scintillator which is set within a polystyrene phantom. When the 'DosiMap' is irradiated, light is produced. This light is composed of scintillation and Cerenkov radiation, and is accurately measured by a C.C.D. camera. The analysis of the light distribution enables us to deduce the dose distribution in the scintillator plan. This device has many advantages such as tissue equivalence, a good spatial resolution, and a linear response with regard to energy. It also provides immediate measurements, and as a consequence, it is a very adapted tool for clinical use. After the introduction about the basic notions of radiotherapy, the different steps of the 'DosiMap' development are exposed in this thesis. In a first time, plastic scintillators have been tested to determine the best one for this application. Then, the deconvolution of scintillation and Cerenkov radiation have been studied, because we only use scintillation to calculate the dose distribution. The camera being in the irradiation room, a lead shield has also been developed to protect the C.C.D. detector from scattered radiations. Finally, the dose calibration and the dose response of 'DosiMap' are exposed. All this work made feasible the measurement of dose distributions with a precision which turns out to be better than 2% for homogeneous photon beams. Excellent results were also obtained when modulated intensity beams are used. (author)

  6. DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS

    Directory of Open Access Journals (Sweden)

    Berger Thomas

    2016-01-01

    Full Text Available The radiation environment encountered in space differs in nature from that on Earth, consisting mostly of highly energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones present on Earth for occupational radiation workers. Since the beginning of the space era, the radiation exposure during space missions has been monitored with various active and passive radiation instruments. Also onboard the International Space Station (ISS, a number of area monitoring devices provide data related to the spatial and temporal variation of the radiation field in and outside the ISS. The aim of the DOSIS (2009–2011 and the DOSIS 3D (2012–ongoing experiments was and is to measure the radiation environment within the European Columbus Laboratory of the ISS. These measurements are, on the one hand, performed with passive radiation detectors mounted at 11 locations within Columbus for the determination of the spatial distribution of the radiation field parameters and, on the other, with two active radiation detectors mounted at a fixed position inside Columbus for the determination of the temporal variation of the radiation field parameters. Data measured with passive radiation detectors showed that the absorbed dose values inside the Columbus Laboratory follow a pattern, based on the local shielding configuration of the radiation detectors, with minimum dose values observed in the year 2010 of 195–270 μGy/day and maximum values observed in the year 2012 with values ranging from 260 to 360 μGy/day. The absorbed dose is modulated by (a the variation in solar activity and (b the changes in ISS altitude.

  7. DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)

    Czech Academy of Sciences Publication Activity Database

    Berger, T.; Przybyla, B.; Matthia, D.; Reitz, G.; Burmeister, S.; Labrenz, J.; Bilski, P.; Horwacik, T.; Twardak, A.; Hajek, M.; Fugger, M.; Hofstatter, C.; Sihver, L.; Palfalvi, J. K.; Szabó, J.; Stradi, A.; Ambrožová, Iva; Kubančák, Ján; Brabcová, Kateřina; Vanhavere, F.; Cauwels, V.; Van Hoey, O.; Schoonjans, W.; Parisi, A.; Gaza, R.; Semones, E.; Yukihara, E.; Benton, E.; Doull, B. A.; Uchihori, Y.; Kodaira, S.; Kitamura, H.; Böhme, M.

    2016-01-01

    Roč. 6, NOV (2016), č. článku A39. ISSN 2115-7251 R&D Projects: GA ČR GJ15-16622Y Institutional support: RVO:61389005 Keywords : International Space Station * Columbus * space radiation * DOSIS * DOSIS 3D Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 2.446, year: 2016

  8. Prenatal radiation doses from radiopharmaceuticals; Dosis absorbida en el feto por administracion de radiofarmacos

    Energy Technology Data Exchange (ETDEWEB)

    Rojo, A M; Gomez Parada, I M; Di Trano, J L

    1999-12-31

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author) 8 refs. [Espanol] La administracion de radiofarmacos con fines diagnosticos o terapeuticos durante el embarazo, resulta en una dosis absorbida en el feto. La evaluacion de esta dosis y la consiguiente estimacion del riesgo radiologico asociado, adquiere relevancia dada la mayor radiosensibilidad de los tejidos fetales con respecto a la de los adultos. El proposito de este trabajo es hacer una revision de los lineamientos existentes sobre las hipotesis a considerar en el calculo de dosis al feto para los radiofarmacos de uso mas frecuente, incorporando las investigaciones recientes que aportan informacion sobre la transferencia placentaria, teniendo en cuenta la edad gestacional. Se analizan las practicas diagnosticas y terapeuticas mas frecuentes comparando las dosis que implican en el feto con los limites internacionalmente aceptados. Se pretende asi disponer de las herramientas necesarias para responder a las consultas sobre los riesgo radiologicos debidos a la administracion de radiofarmacos a embarazadas. (autor)

  9. Low-dose glucocorticoids in hyperandrogenism Efecto de bajas dosis de glucocorticoides en el hiperandrogenismo

    Directory of Open Access Journals (Sweden)

    Leonardo Rizzo

    2007-06-01

    Full Text Available To investigate the effect of low-doses of glucocorticoids on androgen and cortisol secretion during the course of the day, we evaluated clinical signs of hyperandrogenism and total, free and bioavailable testosterone, SHBG, and cortisol following two different protocols: A fourteen patients received betamethasone 0.6 mg/day (n=8 or methylprednisolone 4 mg/day (n=6, as single daily oral dose at 11.00 PM, during 30 days, B fourteen patients were evaluated under betamethasone 0.3 mg in a single daily dose at 11.00 PM during six months, 11 out of whom were re-evaluated six months later. Twenty eight women with hyperandrogenism were included and seven normal females were used as control. Blood samples were taken in follicular phase at 8 AM and 7 PM to determine SHBG, cortisol, total, free and bioavailable testosterone. In both protocols, a significant morning and evening decrease in cortisol and testosterone (pCon el objetivo de investigar el efecto de bajas dosis de glucocorticoides sobre la secreción de andrógenos y cortisol en el curso del día, evaluamos signos de hiperandrogenismo, testosterona total, libre y biodisponible y cortisol según dos protocolos diferentes: A catorce pacientes recibieron betametasona 0.6 mg/día (n= 8 o metilprednisolona 4 mg/día (n= 6 en dosis única cotidiana, a las 23 h, durante 30 días, B catorce pacientes fueron evaluadas bajo betametasona 0.3 mg en dosis única cotidiana a la 23 h, administrada durante 6 meses; de ellas, 11 pacientes fueron re-evaluadas 6 meses más tarde. Se incluyeron 28 mujeres con hiperandrogenismo y 7 controles normales. Se obtuvieron muestras de sangre en fase folicular a las 08:00 y 9:00 h para determinar SHBG, cortisol, testosterona total, libre y biodisponible. En ambos protocolos se observó una disminución significativa de cortisol y testosterona (p<0.05 a <0.01, más importante con betametasona (p<0.05. En el protocolo B, los niveles matutinos de SHBG aumentaron

  10. Development of DosiMap: dosimetry device for radiotherapy quality assurance; Developpement du DosiMap: instrument de dosimetrie pour le controle qualite en radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Frelin, A.M

    2006-10-15

    This thesis deals with the development of a new dosimetry device for the control of radiotherapy beams. This device is composed of a plane plastic scintillator which is set within a polystyrene phantom. When the 'DosiMap' is irradiated, light is produced. This light is composed of scintillation and Cerenkov radiation, and is accurately measured by a C.C.D. camera. The analysis of the light distribution enables us to deduce the dose distribution in the scintillator plan. This device has many advantages such as tissue equivalence, a good spatial resolution, and a linear response with regard to energy. It also provides immediate measurements, and as a consequence, it is a very adapted tool for clinical use. After the introduction about the basic notions of radiotherapy, the different steps of the 'DosiMap' development are exposed in this thesis. In a first time, plastic scintillators have been tested to determine the best one for this application. Then, the deconvolution of scintillation and Cerenkov radiation have been studied, because we only use scintillation to calculate the dose distribution. The camera being in the irradiation room, a lead shield has also been developed to protect the C.C.D. detector from scattered radiations. Finally, the dose calibration and the dose response of 'DosiMap' are exposed. All this work made feasible the measurement of dose distributions with a precision which turns out to be better than 2% for homogeneous photon beams. Excellent results were also obtained when modulated intensity beams are used. (author)

  11. Dose in conventional radiography; Dosis en radiografia convencional

    Energy Technology Data Exchange (ETDEWEB)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico)

    2011-10-15

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  12. Dose to patient in tomosynthesis; Dosis a paciente en tomosintesis

    Energy Technology Data Exchange (ETDEWEB)

    Minambres Moro, A.; Fernandez Leton, P.; Garcia Rui-Zorrilla, J.; Perez Moreno, J. M.; Zucca Aparicio, D.

    2013-07-01

    They are beginning to implement digital mammography with the possibility of acquiring in tomosynthesis, whose biggest advantage is to distinguish structures without overlapping through of pseudotridimensionals images. With these modified mammograms can acquire a planar mammography, with fixed x-ray tube, or a tomosynthesis with tube by turning. For acquire tomosynthesis is necessary a detector of high efficiency together with tungsten white tubes. The objective of this study is to know the dose received by the patient with this new imaging. (Author)

  13. Control letters and uncertainties of the kerma patterns in air, dose absorbed in water and dose absorbed in air of the LSCD; Cartas de control e incertidumbres de los patrones de kerma en aire, dosis absorbida en agua y dosis absorbida en aire del LSCD

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, M T; Tovar M, V M; Cejudo A, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-12-15

    With the purpose of characterizing the component of uncertainty of long term of the patron ionization chambers of the LSCD, for the magnitudes: speed of kerma in air {kappa}{sub {alpha}}{sub {center_dot}}, dose speed absorbed in water D{alpha}{sub {center_dot}}, and speed absorbed dose in air D{alpha}{sub {center_dot}}, it use the technique of letters of control l-MR/S. This statistical technique it estimates the component of uncertainty of short term by means of the deviation standard inside groups {sigma}{sub {omega}} and that of long term by means of the standard deviation among groups {sigma}{sub {beta}}, being this it finishes an estimator of the stability of the patterns.The letters of control l-MR/S it construct for: i) {kappa}{sub {alpha}}{sub {center_dot}}, in radiation field of {sup 60}Co for patterns: primary CC01 series 131, secondary NE 2611 series 176, secondary PTW TN30031 series 578 and Third PTW W30001 series 365. ii) D{alpha}),en radiation field of {sup 60}Co for patterns: primary CC01 series 131, Secondary PTW TN30031 series 578 and tertiary PTW W30001 series 365. iii) I-MR/S with extrapolation chamber PTW primary pattern, measurement realizes in secondary patron fields of {sup 90}Sr-{sup 90}Y. The expanded uncertainty U it is calculated of agreement with the Guide of the ISO/BIPM being observed the following thing: a. In some the cases {sigma}{sub {beta}}, is the component of the U that more contributed to this. Therefore, it is necessary to settle down technical of sampling in those mensurations that allow to reduce the value of {sigma}{sub {beta}}. For example with sizes of subgroup {eta}{sub {approx}} 30 data, or with a number of subgroups {kappa}{sub {>=}}. That which is achieved automating the mensuration processes. b.The component of the temperature is also one of those that but they contribute to the U, of there the necessity of: to recover the tracking for this magnitude of it influences and to increase the precision in the

  14. Preparation of an application for the control of the dose delivered by equipment of computed tomography (CT); Elaboracion de una aplicacion para el control de la dosis impartida por equipos de tomografia computerizada (TC)

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Agulla Otero, M.; Hernando Gonzalez, I.

    2013-07-01

    Although TC are native digital equipment, the collection and treatment of the doses given to the patients it continues to present difficulties to date, especially in the still very large number of teams that do not produce a formal report of dose (SR). This work shows the experience gained in the development of an application that allows the calculation, monitoring and control of the dose given to patients by teams of TC. (Author)

  15. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products; Sistemas dosimetricos de altas dosis, tasa de dosis y uniformidad de dosis en alimentos y producto medico

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, J.; Vivanco, M.; Castro, E., E-mail: jvargas@ipen.gob.pe [Instituto Peruano de Energia Nuclear, Av. Canada 1470, San Borja, Lima (Peru)

    2014-08-15

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  16. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  17. Experimental method for calculation of effective doses in interventional radiology; Metodo experimental para calculo de dosis efectivas en radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz Lblanca, M. D.; Diaz Romero, F.; Casares Magaz, O.; Garrido Breton, C.; Catalan Acosta, A.; Hernandez Armas, J.

    2013-07-01

    This paper proposes a method that allows you to calculate the effective dose in any interventional radiology procedure using an anthropomorphic mannequin Alderson RANDO and dosimeters TLD 100 chip. This method has been applied to an angio Radiology procedure: the biliary drainage. The objectives that have been proposed are: to) put together a method that, on an experimental basis, allows to know dosis en organs to calculate effective dose in complex procedures and b) apply the method to the calculation of the effective dose of biliary drainage. (Author)

  18. Dose and dose reduction in computed tomography; Dosis und Dosisreduktion in der Computertomografie

    Energy Technology Data Exchange (ETDEWEB)

    Lell, Michael [Klinikum Nuernberg (Germany). Inst. fuer Radiologie und Nuklearmedizin; Paracelsus Medical Univ. Nuernberg (Germany); Wucherer, Michael [Klinikum Nuernberg (Germany). Inst. fuer Medizinische Physik; Kachelriess, Marc [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany)

    2017-06-15

    CT is widely used in medical imaging due to high availability, relatively low cost, and excellent diagnostic yield. Newer applications like coronary CTA, CT colonography, and CT perfusion imaging are integrated in clinical pathways. Although there is a high level of consensus that the benefits of CT exceeds the risks of radiation exposure for appropriate indications, concerns have been raised regarding the potential of cancer induction. Keeping dose as low as reasonably achievable remains the most important task. Dose reduction strategies are presented and discussed.

  19. Efecto de diferentes dosis de aspirina sobre el precondicionamiento contra el atontamiento en ovejas Effect of different doses of aspirin on preconditioning against stunning in conscious sheep

    Directory of Open Access Journals (Sweden)

    Elena C. Lascano

    2004-02-01

    Full Text Available Se ha postulado que los antiinflamatorios no esteroides que actuan inhibiendo la ciclooxigenasa (COX podrían tener efectos nocivos sobre el corazón. Recientemente se ha demostrado que los inhibidores de la COX-2 bloquean la protección por precondicionamiento tardío (PT. Se desconoce sin embargo, el efecto que pudiera tener la aspirina, el antiinflamatorio no esteroide más ampliamente utilizado en la clínica, sobre el PT en mamíferos grandes. La aspirina actúa inhibiendo las dos isoenzimas de la ciclooxigenasa (COX-1 y COX-2, siendo empleada en dosis altas como droga antiinflamatoria y en dosis bajas como agente antitrombótico. El propósito de este estudio fue analizar qué efecto tienen distintas dosis de aspirina sobre la protección del PT contra el atontamiento y las arritmias en ovejas conscientes. Se consideraron 5 grupos; control (C: 12 min de isquemia (I y 2 hr de reperfusión (R; PT: 6 períodos de 5 min I-5 min R, 24 hr antes de la I de 12 min, y tres grupos igual que PT, pero con 1.5 (PTA1.5, 8 (PTA8 y 20 (PTA20 mg/kg de aspirina respectivamente, administrados 10 min antes de la primera I de precondicionamiento. Los resultados demostraron que la dosis antiinflamatoria de aspirina (20 mg/kg fue capaz de inhibir el PT contra el atontamiento (C vs PTA20, NS, mientras que las dosis bajas (1.5 mg/kg e intermedia (8 mg/kg no afectaron la protección (C vs PT, PT1.5 y PT8, pNon-steroid antiinflammatory drugs, inhibitors of cyclooxigenase (COX, have been postulated to have deletereous effects on the heart. Recently, COX-2 inhibitors have also been found to block late preconditioning (LP protection. Aspirin is the most widely clinically used non-steroid antiinflammatory drug; yet its effect on LP in big mammals has not been determined. It inhibits the two cyclooxigenase isoenzymes (COX-1 and COX-2, at high doses being used as an antiinflammatory drug and at low doses as an antithrombotic agent. The goal of this study was thus, to

  20. Managing patient dose in digital radiology; Gestión de la dosis al paciente en radiología digital

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission

  1. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  2. Cytogenetics dosimetry: dose-response curve for low doses of X-ray; Dosimetria citogenetica: curva dosis-respuesta para bajas dosis de rayos-X

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Virginia E. Noval; Pineda Bolivar, William R.; Riano, Victor M. Pabon, E-mail: venovall.15@hotmail.com, E-mail: wrpineda@misena.edu.co, E-mail: vmpabonr@udistrital.edu.co [Universidad Distrital Francisco Jose de Caldas (UD), Bogota (Colombia). Grupo de Investigacion en Ciencia y Tecnologia Nuclear; Ureana, Cecilia Crane, E-mail: cecicrane@yahoo.com [Instituto Nacional de Salud (INS), Bogota (Colombia). Laboratorio de Genetica

    2013-07-01

    The purpose of this study was to conduct a preliminary study for the standardization in the future, the dose-response curve for low doses of X-rays, through the analysis of in vitro cultures of peripheral blood samples of 3 men and 3 women occupationally not exposed to artificial sources of ionizing radiation, age 18-40 years, where possible nonsmokers.

  3. Dose in water or dose in tissue. Still a theme of debate; Dosis en agua o dosis en tejido-todavia un tema de debate

    Energy Technology Data Exchange (ETDEWEB)

    Andreo, P.

    2015-07-01

    It is shown that the method used so Siebers to convert to Dw Dt, or vice versa, is incorrect. Due to the substantial difference between the electron fluence in water and various tissues, an additional correction for creep, several percent for some bone tissues, which is ignored in the method Siebers needed. Correction is necessary even if an environment that clinically adopted dose in tissue due to normalization of TPS because the beams are always calibrated in terms of absorbed dose in water. (Author)

  4. Quality control and assurance for validation of DOS/I measurements

    Science.gov (United States)

    Cerussi, Albert; Durkin, Amanda; Kwong, Richard; Quang, Timothy; Hill, Brian; Tromberg, Bruce J.; MacKinnon, Nick; Mantulin, William W.

    2010-02-01

    Ongoing multi-center clinical trials are crucial for Biophotonics to gain acceptance in medical imaging. In these trials, quality control (QC) and assurance (QA) are key to success and provide "data insurance". Quality control and assurance deal with standardization, validation, and compliance of procedures, materials and instrumentation. Specifically, QC/QA involves systematic assessment of testing materials, instrumentation performance, standard operating procedures, data logging, analysis, and reporting. QC and QA are important for FDA accreditation and acceptance by the clinical community. Our Biophotonics research in the Network for Translational Research in Optical Imaging (NTROI) program for breast cancer characterization focuses on QA/QC issues primarily related to the broadband Diffuse Optical Spectroscopy and Imaging (DOS/I) instrumentation, because this is an emerging technology with limited standardized QC/QA in place. In the multi-center trial environment, we implement QA/QC procedures: 1. Standardize and validate calibration standards and procedures. (DOS/I technology requires both frequency domain and spectral calibration procedures using tissue simulating phantoms and reflectance standards, respectively.) 2. Standardize and validate data acquisition, processing and visualization (optimize instrument software-EZDOS; centralize data processing) 3. Monitor, catalog and maintain instrument performance (document performance; modularize maintenance; integrate new technology) 4. Standardize and coordinate trial data entry (from individual sites) into centralized database 5. Monitor, audit and communicate all research procedures (database, teleconferences, training sessions) between participants ensuring "calibration". This manuscript describes our ongoing efforts, successes and challenges implementing these strategies.

  5. Crystalline dose of interventional radiologists; Dosis en cristalino de radiologicos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Concepcion, E.; Diaz Romero, F.; Catalan Acosta, A.; Hernandez Armas, J.

    2013-07-01

    The measured dose area product in radiology equipment used in angio radiology during different diagnostic and therapeutic can be used to estimate the value of the dose in the lens of doctors or medical personnel carrying out such interventions. (Author)

  6. Dose evaluation in diagnostic for computerized tomography; Evaluacion de dosis en diagnostico por tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Flores, W.; Borges, J.C.; Mota, H. [Universidad Federal de Rio de Janeiro, PEN/COPPE/UFRJ. Caixa Postal 68509. 21945-970 Rio de Janeiro (Brazil)

    1998-12-31

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  7. Sources of C-14 generation and associated doses; Fuentes de generacion de C-14 y dosis asociadas

    Energy Technology Data Exchange (ETDEWEB)

    Amado, Valeria A; Biaggio, Alfredo L; Canoba, Analia C; Curti, Adriana R. [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)], E-mail: vamado@cae.arn.gov.ar

    2009-07-01

    C-14 is a radioactive isotope of C with a half-life of 5700 years that decays to N-14 by emission of beta radiation. It is naturally produced in the upper atmosphere by cosmic ray neutrons via the (n;p) reaction over N-14. Anthropogenic C-14 has been generated in the past by atmospheric nuclear weapon tests and it is currently produced during the operation of nuclear reactors. Once released this radionuclide behaves in the biosphere as the standard carbon cycle. Since the beginning of the industrial period the relationship Carbon-14/Stable Carbon has changed continuously, and so the dose incurred by the world population. In this paper the main anthropogenic activities that modified such relationship are presented and analyzed: the Suess effect and the generation of nuclear energy. It is concluded that the current trend of reduction of the total dose due to C-14 will continue during the next decades. Finally it is indicated that in order to prevent an excessive accumulation of this radionuclide in the biosphere, actions should be collectively implemented to be effective. (author) [Spanish] El C-14 es un isotopo radiactivo del C con un periodo de semidesintegracion igual a 5700 anios y que decae a N-14 por emision de radiacion beta. Se produce naturalmente en las altas capas de la atmosfera debido a la reaccion N-14(n,p)C-14 inducida por neutrones lentos de rayos cosmicos. El C-14 antropogenico se genero debido a los ensayos nucleares y actualmente es producido durante la operacion de los reactores nucleares. Una vez liberado se incorpora a la biosfera a traves del ciclo del carbono. A partir de los inicios del periodo industrial la relacion C-14/C-estable, y por ende la dosis debida a C-14 que recibiria la poblacion mundial, ha variado continuamente. El objetivo del presente trabajo es presentar y analizar los distintos factores antropogenicos que modifican la concentracion de C-14, en particular el efecto Suess y la generacion de energia nuclear. Se observa que las

  8. Dose estimation in embryo or fetus in external fields; Estimacion de dosis en embrion o feto

    Energy Technology Data Exchange (ETDEWEB)

    Gregori, Beatriz N [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)

    2001-07-01

    The embryo or the fetus can be irradiated as result of radiological procedures of diagnosis of therapy in where the beam effects directly on the same one or in tissues or peripherical organs. Some authors have suggested that in the first stages of the pregnancy the dose in ovaries can be the good estimated of the dose in embryo or fetus. In advanced conditions of the development, probably also in the early stage, is more appropriated to specify the dose in the embryo or fetus equal of the uterus. The dose in the uterus is a good estimated so much for external irradiation as for radionuclides incorporation.

  9. Dose determination in computed tomography; Determinacion de dosis en tomografia computada

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, C.; Garrigo, E.; Venencia, D. [Fundacion Marie Curie, Instituto Privado de Radioterapia, Departamento de Fisica Medica, Obispo Oro 423, X5000BFI Cordoba (Argentina); Gonzalez, M. [Universidad Nacional de Cordoba, Facultad de Ciencias Exactas, Fisicas y Naturales, Av. Velez Sarsfield 299, Corboba (Argentina); Germanier, A., E-mail: agermani@ceprocor.uncor.edu [Ministerio de Ciencia y Tecnologia, Ceprocor, Alvarez de Arenas 230, X5004AAP Barrio Juniors, Cordoba (Argentina)

    2011-10-15

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  10. The dose makes the poison. Even for radiation; Die Dosis macht das Gift. Auch bei Strahlenbelastung

    Energy Technology Data Exchange (ETDEWEB)

    Langeheine, Juergen

    2014-11-15

    The dose makes the poison, a quote by Paracelsus a doctor who lived half a millennium ago, is still valid today. Nevertheless this general accepted fact is being excluded in relation to ionizing radiation, which is wrongly considered as radioactive radiation. Here applies the LNT-Hypothesis (Linear No Threshold), agreed on by the ICRP, the Commission on Radiological Protection, a dose-to-effect relationship, which is based on the EU directives and the German Radiation Protection Ordinance. The LNT-hypothesis states, that even every smallest dose of radiation already provides a potentiality of danger and was introduced as precaution assuming that self-healing mechanisms even through weak radiation of damaged cells can be excluded and every damage caused by radiation inevitably leads to cell mutation and with it to cancer development. Without any further knowledge assumptions were made, that the same mechanism for cancer development applies for high and small doses. This assumption turned out to be wrong, as it is increasingly reported on findings which show, that smaller doses of ionized radiation demonstrably does not cause any damage, but on the contrary can even be healthy.

  11. Methodology to administer therapeutic dose of I-131; Metodologia para administrar dosis terapeutica de I-131

    Energy Technology Data Exchange (ETDEWEB)

    Basteris M, J.; Gomez D, R. [Universidad Autonoma de Yucatan, Facultad de Medicina, Merida, Yucatan (Mexico)

    2007-07-01

    The present work suggests the use of measures guided to eliminate the resulting chronic sialoadenitis of the treatment of the thyroid cancer with Iodine-131, as well as the use of citric fruits to stimulate the salivation, the post-dose administration of liquids to accelerate the gastric emptying avoiding the secondary effects as the vomit is included. (Author)

  12. Fetal dose in radiology, nuclear medicine and radiotherapy; Dosis fetal en radiodiagnostico, medicina nuclear y radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, F. J.; Martinez, L. C.; Candela, C.

    2015-07-01

    Sometimes irradiation of the fetus in the mother's womb is inevitable in the field of diagnostic radiology, nuclear medicine and radiotherapy, either through ignorance a priori status of this pregnancy, either because for clinical reasons it is necessary to perform the radiological study or treatment. In the first cases, know the dose at which it has exposed the fetus is essential when assessing the associated risk, while in the second it is when assessing the justification of the test. (Author)

  13. Dose estimation by biological methods; Estimacion de dosis por metodos biologicos

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C; David C, L; Serment G, J; Brena V, M [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The human being is exposed to strong artificial radiation sources, mainly of two forms: the first is referred to the occupationally exposed personnel (POE) and the second, to the persons that require radiological treatment. A third form less common is by accidents. In all these conditions it is very important to estimate the absorbed dose. The classical biological dosimetry is based in the dicentric analysis. The present work is part of researches to the process to validate the In situ Fluorescent hybridation (FISH) technique which allows to analyse the aberrations on the chromosomes. (Author)

  14. Analysis of fetal dose in CT procedures; Analisis de dosis fetal en procedimientos de tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Torres, A.; Plazas, M. C.

    2006-07-01

    It is the miracle of the life, that sublime formation, the given more beautiful gift for heaven's sake to our to exist, and it is consequently our responsibility to look after their protection and care. Today in day the quantity of radiation absorbed by the fetus in the treatments for radiodiagnostic, mainly in the procedures of on-line axial tomography, the fetus absorbs a considerable dose of radiation and the questions generated regarding if these doses, bear to a risk of malformations or if it is necessary the interruption of the pregnancy is very frequent. In most of the cases, the treatment with ionizing radiations that it is beneficial for the mother, is only indirectly it for the fetus that is exposed to a risk. The possibility that a fetus or a small boy contract cancer caused by the radiation it can be three times superior to that of the population in general, of there the importance of analyzing the goods of the prenatal irradiation and the main agents to consider for the estimate of the magnitude of the risk of the exhibitions in uterus. In the different circumstances in that these can happen in treatments of on-line axial tomography computerized. (Author)

  15. Tratamiento con dosis moderada de hidroxiurea en la drepanocitosis Treatment with moderate doses of hydroxyurea in drepanocytosis

    Directory of Open Access Journals (Sweden)

    Sergio Machín García

    2008-08-01

    Full Text Available En el período comprendido entre junio del 2003 y junio del 2005 se trataron con hidroxiurea 45 pacientes con anemia drepanocítica; 16 niños y 29 adultos, al menos con una de las manifestaciones siguientes: más de 3 crisis vasooclusivas (CVO dolorosas al año en los 3 años previos al estudio, uno o más episodios de síndrome torácico agudo (STA al año en los 2 años previos al estudio, o accidente vascular encefálico (AVE en el año anterior. La hidroxiurea se administró en dosis de 15mg/kg/día. El número de CVO dolorosas, STA, AVE, ingresos y transfusiones disminuyó significativamente (pFrom June 2003 to June 2005, 45 patients with drepanocytic anemia, 16 children and 29 adults, with at least one of the following manifestations were treated with hydroxyurea: more than 3 painful vasoocclusive crises (VOC at a year and 3 years before the study, one or more episodes of acute thoracic syndrome (ATS at a year and 2 years previous to the study, or vascular encephalic accident (VEA in the previous year. Hydroxyurea was administered at doses of 15mg/kg/day. The number of painful VOC, ATS, VEA, admissions and transfusions decreased significantly (p<0.001. There was not either reduction of the hematological parameters or increase of creatinin or alanine aminotransferase. An important rise of fetal hemoglobin values (p<0.008 was reported. There were no toxic manifestations and the fulfilment was good. It was proved in this paper that it is not necessary to take the maximum tolerated dose of hydroxyurea to improve the clinical picture in drepanocytic anemia. Two of its advantages are its lower toxicity and the less expensive treatment. This would make possible that a greater amount of children in those countries with scarce resources may benefit from the treatment.

  16. Dosis elevada en el dosímetro personal de una auxiliar de enfermería en Electrofisiología A high dose in the personal dosage meter of nursing assistant in Electrophysiology field

    Directory of Open Access Journals (Sweden)

    Raquel Barquero Sanz

    2012-03-01

    Full Text Available En una sala de Electrofisiología del Servicio de Cardiología en donde se efectúan procedimientos guiados con rayos X de ablación con radiofrecuencia y de implantes de desfibrilador biventricular, se registraron dosis mensuales anormalmente elevadas en el dosímetro personal de solapa de una auxiliar de enfermería que trabaja en la misma, con valores de dosis equivalente personal, Hp(10, de 125 mSv y de dosis equivalente personal superficial, Hp(0.07 de 128.1 mSv. Ante la ansiedad producida en la trabajadora al conocer las lecturas de su dosímetro, y dado que no se dispone de precedentes investigados en la instalación, se ha realizado un estudio para dilucidar si la dosis registrada ha podido ser recibida por la trabajadora o si solo ha sido recibida por el dosímetro. Se hacen medidas con un monitor ambiental en condiciones simuladas de los procedimientos, para estimar las dosis reales que pueda recibir el personal de la sala. Se comparan estos valores con los del rendimiento del equipo de RX en haz directo medidos durante la revisión anual de control de calidad del mismo, concluyéndose que ha sido el dosímetro, y no la trabajadora, el que se ha expuesto a radiación directa, siendo la situación más probable la de que dicho dosímetro cayó sobre el tubo de RX, normalmente orientado hacia el techo, un tiempo del orden de 1 minuto. Paralelamente a estas estimaciones dosimétricas, el Servicio de Prevención de Riesgos Laborales realizó la vigilancia de la salud, concluyendo que la trabajadora no tenía ningún indicio de haber recibido dosis de la magnitud registrada por su dosímetro.In a room of electrophysiology from the cardiology service where procedures are made guided with X-Rays of ablation with radiofrequency and from implants ventricular defibrillation; there were registered monthly doses usually high in the same personal dosimeter flap of a nursing assistant who works there with values of equivalent personal doses, Hp (10

  17. Efecto de la dosis de glifosato sobre la biomasa de malezas de barbecho al estado vegetativo y reproductivo Glyphosate dose effect on weed biomass at the vegetative and reproductive stage

    Directory of Open Access Journals (Sweden)

    E. Puricelli

    2009-06-01

    Full Text Available Los experimentos se condujeron en el campo experimental de la Facultad de Ciencias Agrarias ubicado en Zavalla (Argentina durante 2005 y 2006. El objetivo de este trabajo fue estudiar la eficacia de glifosato aplicado al estado vegetativo y reproductivo de Convolvulus arvensis, Oenothera indecora, Iresine diffusa, Parietaria debilis, Rumex paraguayensis y Trifolium repens. El diseño del experimento fue completamente al azar con un arreglo factorial: año, especies, estado reproductivo y vegetativo y dosis de glifosato 48% (4X, 2X, 1X, 1/2X, 1/4X, 0X siendo X la dosis recomendada 1200 g i.a. ha-1. Se estableció la relación entre la dosis de glifosato y el control de la biomasa de las malezas a través de curvas de dosis respuesta con un modelo log-logístico. Se comparó el grado de tolerancia por medio de la DL50. En ambos estados de las malezas, la mayor DL50 obtenida para I. diffusa indica que de las especies estudiadas ésta es la más tolerante a glifosato. El número de especies tolerantes al glifosato es menor al estado vegetativo que al reproductivo.Experiments were conducted at the University of Rosario Experimental Farm, Zavalla in 2005 and 2006 to study the effect of glyphosate on the control of Convolvulus arvensis, Oenothera indecora, Iresine diffusa, Parietaria debilis, Rumex paraguayensis and Trifolium repens at the vegetative and reproductive stage. The experiments were established in a complete randomized design with the following factorial arrangement of treatments: year, species, vegetative and reproductive growth stages and glyphosate 48% (4X, 2X, 1X, 1/2X, 1/4X, 0X being 1X the recommended dose (1,200 g a.i. ha-1. The relationship between glyphosate dose and weed biomass control was established with a log-logistic model. The degree of tolerance was compared by LD50. In both stages, the higher LD50 was obtained for I. diffusa indicating that this is the species most tolerant to glyphosate among those studied. The number of

  18. In vivo Tl dosimetry for the quality control in Radiotherapy with {sup 60} Co and brachytherapy of low dose rate; Dosimetria Tl in vivo para el control de calidad en Radioterapia con {sup 60} Co y Braquiterapia de baja tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Velez, G.; Bustos, S.; Balmaceda, O.; Gutierrez, S.; Ferraris, M. [Servicio de Radioterapia, Hospital San Roque. Rosario de Santa Fe 374. CP 5000. Cordoba (Argentina)

    1998-12-31

    In vivo dosimetry is used every time with more frequency as a valuable tool for the quality control in Radiotherapy. The measurements of input and output doses provide us information about the technique accuracy or the treatment procedure used; likewise the dose measurement which rectum or bladder receive in gynecologic implants contribute to the improving and adjusting the procedures in brachytherapy. Besides, it may be identify systematic errors in particular situations which allow to optimize the treatment and to minimize errors. It was realized a study at the Radiotherapy service in San Roque Hospital (Cordoba) to control the procedures used in the treatment of distinct oncologic pathologies. Its were selected patients, which were realized the routine planning with the planning system of computerized treatments Prowess 3000, that later its were controlled with In vivo thermoluminescent dosimetry using the Ceprocor Services (Cordoba). Its were realized dose skin measurements in treatments of mammary gland, pelvis, thorax, head and neck and it were measured doses in body cavities, as oral cavity, rectum, esophagus, etc. arranging the TLD inside special catheters. In the case of dose skin, the dosemeters were arranged in acrylic porta-dosemeters, at pairs, which later they were enveloped and sealed. It was founded a very good agreement among the In vivo measurements and the predicted by the planner. In some cases, the control allows to modify the treatment for to avoid over or sub dosages of the distinct organs affected by the radiation field. (Author)

  19. Evaluación de la nitazoxanida en dosis única y por tres días en parasitosis intestinal Nitazoxanide vs albendazole against intestinal parasites in a single dose and for three days

    Directory of Open Access Journals (Sweden)

    Uri Belkind-Valdovinos

    2004-08-01

    Full Text Available OBJETIVO: Evaluar la utilidad de nitazoxanida en dosis habitual con esquema de tres días y en dosis única, para la erradicación masiva de parásitos intestinales en la población pediátrica, comparando su efecto con el del albendazol en dosis única. MATERIAL Y MÉTODOS: Se realizó un ensayo clínico aleatorizado, en tres comunidades rurales de la región central de México, durante el periodo 2001-2003, para incluir tres posibles alternativas de tratamiento en 786 sujetos de entre 5 y 11 años de edad, de los cuales 92 tuvieron un examen parasitológico positivo (15.1%. El grupo 1 incluyó 27 pacientes que recibieron 400 mg de albendazol en dosis única; el grupo 2 incluyó 34 pacientes a quienes se administró nitazoxanida en dosis de 15 mg/kg/día durante tres días consecutivos; y el grupo 3 incluyó 31 pacientes que recibieron 1.2 g de nitazoxanida en dosis única. Se evaluó diferencia de proporciones mediante prueba exacta de Fisher. RESULTADOS: No existieron diferencias estadísticamente significativas en la efectividad de los tres esquemas de tratamiento: (80.5% con albendazol, comparado con las dos alternativas adicionales de nitazoxanida (67.6% y 71%, respectivamente. Se observó una mayor prevalencia de efectos secundarios con nitazoxanida por kg /día (26.5% y en dosis única (32.2%, en comparación con la dosis única de albendazol (7.4%. CONCLUSIONES: Las evidencias en cuanto a la efectividad y elevada prevalencia de efectos secundarios de la nitazoxanida no justifican aún su utilización como quimiopreventivo masivo para el control de parasitosis intestinal en áreas endémicas. En países con elevada prevalencia de parasitosis intestinal las medidas de prevención primaria que continúan vigentes, y que deben priorizarse, están relacionadas con sanidad pública, introducción de agua potable y drenaje, cloración de agua y manejo adecuado de excretas de animales domésticos, así como educación para la salud.OBJETIVE: To

  20. Precision and accuracy control of dose calibrator: CAPINTEC CRC 12 in laboratory for radiopharmacy of Nuclear Medicine Institute of Sucre, Bolivia; Control de precision y exactitud del calibrador de dosis: CAPINTEC CRC 12 del Laboratorio de Radiofarmacia del Instituto de Medicina Nuclear Sucre

    Energy Technology Data Exchange (ETDEWEB)

    Huanca Sardinas, E; Castro Sacci, O; Torrez Cabero, M; Vasquez Ibanez, M.R; Zambrana Zelada, AJ., E-mail: nuclear_sre@entelnet.bo, E-mail: ehuancasardinas@hotmail.com, E-mail: marcetorrez@hotmail.com, E-mail: maritavas@yahoo.es, E-mail: alfzambrana@gmail.com [Universidad Mayor Real y Pontifica de San Francisco Xavier de Chuquisaca, Sucre (Bolivia, Plurinational State of). Radiofarmacia - Instituto de Medicina Nuclear de Sucre. Hospital Santa Barbara

    2013-11-01

    The dose calibrator is one of the indispensable tools in radiopharmacy laboratories of a nuclear medicine department also is mandated to provide accurate readings. A very high doses produce unnecessary radiation exposure to the patient or a very low dose, prolong the acquisition time of the studies affecting the quality of the image. In the present work we did a retrospective analysis of the results of quality checks performed at precision accuracy of the Gauge CRC12 CAPINTEC dose calibrator over a period of 16 years, using sealed certified sources with low power, medium and high: Ba{sup 133} , Cs{sup 137} , Co{sup 60} and Co{sup 57}. The results showed that the lowest standard deviation value was 0.17 for Ba133, relative to Co{sup 57} of 2.97 in the control of accuracy. Accuracy over control values were also lower standard deviation for Ba{sup 133} 1.00, relative to Co{sup 57} 10.06. Being stated that the CRC12 CAPINTEC activimeter reliability is acceptable during the reporting period and under the conditions indicated. Therefore, we continue to make these quality control procedures and the professional must feel confident that the measurements obtained with it are reliable.

  1. Frequency and doses of diagnostic and interventional X-ray applications. Trends between 2007 and 2014; Haeufigkeit und Dosis diagnostischer und interventioneller Roentgenanwendungen. Trends zwischen 2007 und 2014

    Energy Technology Data Exchange (ETDEWEB)

    Nekolla, E.A. [BfS - Bundesamt fuer Strahlenschutz, Abteilung Medizinischer und Beruflicher Strahlenschutz, Neuherberg (Germany); Schegerer, A.A.; Griebel, J.; Brix, G.

    2017-07-15

    In Germany, approximately 95% of man-made radiation exposure of the population results from diagnostic and interventional X-ray procedures. Thus, radiation protection of patients in this field of application is of great importance. Quantification and evaluation of current data on the frequency and doses of X-ray procedures as well as temporal trends for the years 2007-2014. For outpatients the frequency of X-ray procedures was estimated using reimbursement data from health insurances and for inpatients by means of hospital statistics. For the years under review, representative values for the effective dose per X-ray application were determined mainly from data reported by X-ray departments to the competent authorities. In 2014 approximately 140 million X-ray procedures were performed in Germany with some 40% from dental examinations. On average 1.7 procedures per inhabitant and year were almost constantly carried out between 2007 and 2014. Besides dental diagnostics, X-ray examinations of the skeleton and thorax were performed most frequently. The number of computed tomography (CT) examinations increased by approximately 40%. The increase in magnetic resonance imaging (MRI) was even more pronounced with approximately 55% but overall CT examinations were still performed more often than MRI. The doses per X-ray procedure were only slightly reduced, despite the various dose reduction approaches established in recent years; therefore, the mean effective dose per inhabitant increased from approximately 1.4 mSv in 2007 to 1.6 mSv in 2014, mainly due to the increasing frequency of CT examinations. The principles of justification and optimization of radiological procedures are to be consistently applied in each individual instance, especially in the case of CT examinations. (orig.) [German] In Deutschland resultieren etwa 95 % der zivilisatorischen Strahlenexposition der Bevoelkerung aus diagnostischen und interventionellen Roentgenanwendungen, sodass dem Strahlenschutz

  2. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  3. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films; Control de calidad de imagen del equipo de mamografia -Mammography System MX-300- del Hospital de Docentes de la UNSA y medicion de dosis en mamas con peliculas radiograficas

    Energy Technology Data Exchange (ETDEWEB)

    Quispe F, L. K.; Vega R, J., E-mail: karinaqflores839@gmail.com [Universidad Nacional de San Agustin, Escuela Profesional de Fisica, Arequipa (Peru)

    2015-10-15

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  4. Interventional radiology simulation and measurement of patient doses; Simulacion en radiologia intervencionista y medida de dosis a pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz Lablanca, M. d.; Diaz Romero, F.; Hernandez Armas, J.

    2011-07-01

    In this paper we propose a method of work to calculate the effective dose in any interventional radiology procedure using an Alderson Rando anthropomorphic phantom and dosimeters TLD 100 chip. We applied this method in the case of biliary drainage and allowed us to establish the dose value corresponding reference in the Hospital Universitario de Canarias (HUC).

  5. Methodology for management of therapeutic dose of I-131; Metodologia para administrar dosis terapeutica de I-131

    Energy Technology Data Exchange (ETDEWEB)

    Basteris M, J.; Gomez D, R. [Universidad Autonoma de Yucatan, Facultad de Medicina, Merida, Yucatan (Mexico)

    2007-07-01

    The present work suggests the use of measures guided to eliminate the resulting chronic sialoadenitis of the treatment previously described with a therapeutic dose bigger than ablative of Iodine 131, as well as the use of citric fruits to stimulate the salivation, the administration of liquid post-dose is included to accelerate the gastric emptying avoiding the secondary effects as the vomit. (Author)

  6. Risks of low dose ionising radiation exposures Riesgos derivados de la exposición a dosis bajas de radiación ionizante

    Directory of Open Access Journals (Sweden)

    Almudena Real Gallego

    2010-12-01

    Full Text Available Although ionising radiation has been shown to have several beneficial applications for humans, it can also produce detrimental effects in humans and the environment. To adequately protect man and environment from the potential harmful effects of ionising radiation, is essential to know in detail the biological effects produced by it, its characteristics and the various factors that influence these effects. That is the objective of this article, describe the current status of knowledge about biological effects induced by ionising radiation, with special emphasis on those effects occurring after low dose exposures.La radiación ionizante ha mostrado tener diversas aplicaciones beneficiosas para el hombre, pero también puede dañar la salud de las personas y el medio ambiente. Para proteger adecuadamente al hombre de los posibles efectos nocivos de la radiación ionizante es imprescindible conocer en detalle los efectos biológicos producidos por esta, sus características y los distintos factores que influyen en dichos efectos. Ese es el objetivo de este artículo: describir el estado actual del conocimiento sobre los efectos biológicos que puede producir la radiación ionizante, con especial énfasis en aquellos efectos que se producen tras la exposición a dosis bajas.

  7. Estimated occupational dose in interventional procedures crystalline; Estimacion de la dosis ocupacional en el cristallino en procedimientos interveniconistas

    Energy Technology Data Exchange (ETDEWEB)

    Portas Ferradas, B. C.; Chapel Gomez, M. L.; Jimenez Alarcon, J. I.

    2011-07-01

    This paper present the result of the estimated doses in the eyes of workers exposed for radiology procedures and interventional cardiology from measurements made with thermoluminescent dosimeter placed near the lens.

  8. Efeitos de algumas características do solo na resposta da planta a doses de herbicidas Effect of some soil characteristics on plant response to herbicide dosis

    Directory of Open Access Journals (Sweden)

    E. M. Paulo

    1991-01-01

    Full Text Available Foram estudados em casa de vegetação o tempo de sobre vivência de oito espécies olerícolas a aplicação de atrazina nas doses correspondentes a 1,8 e 3,2 kg/ha, e de diuron nas doses de 1,2 e 2,0 kg/ ha, em três tipos de solos ácidos tropicais. Os resultados mostraram alta correlação linear entre o tempo médio de vida das plântulas com teores de matéria orgânica, capacidade de troca catiônica (CTC efetiva e pH do solo; e baixas correlações com teores de argila mais silte. Os resultados indicam ser mais adequado tomar como base a característica CTC do solo em lugar da sua classificação textural para fins de recomendação das doses dos herbicidas.A study was conducted in green house to determine the survival time of eight vegetable plant species to soil application of 1,8 and 3,2 kg/ha of atrazine, and 1,2 and 2,0 kg/ha of diuron, in three tropical soils. High line ar correlation was obtained betwe en avera ge survi val time and organic matter content, cation exchange capacity (CEC and soil pH; and low correlation with clay or clay plus silt content. The results lead to the conclusion that it seems more consistent to consider CEC inste ad of soil texture on dosis recommendation fow both herbicides.

  9. Estimation of effective dose during hysterosalpingography procedures; Estimación de dosis efectiva durante los procedimientos hysterosalpingography

    Energy Technology Data Exchange (ETDEWEB)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433, (Saudi Arabia); Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj (Saudi Arabia); Alsafi, K. [King Abdulaziz University, Faculty of Medicine, Radiology Department, Jeddah 22254 (Saudi Arabia); Omer, H., E-mail: kalzimami@ksu.edu.sa [Dammam University, Faculty of Medicine, Dammam Khobar Coastal Rd, Khobar 31982 (Saudi Arabia)

    2014-08-15

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  10. Measurement of doses to aviator pilots using thermoluminescent dosemeters; Medicion de la dosis a pilotos aviadores usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J.; Cruz C, D. [UAM-I, 09340 Mexico D.F. (Mexico); Rivera M, T. [IPN, ESIME Culhuacan (Mexico)]. e-mail: azorin@xanum.uam.mx

    2004-07-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  11. Indicators of image quality and doses in mammography; Indicadores de calidad de imagen y dosis en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Franco E, J.G. [UAM-X, Calz. del Hueso 1100, 04960 Mexico D.F. (Mexico); Azorin N, J.; Diaz G, J.A.I. [CICATA-IPN, 11500 Mexico D.F. (Mexico); Arreola, M. [Shands Hospital at UF, PO Box 100374, Gainesville FL 32610-0374 (United States)

    2007-07-01

    Full text: The purpose of the study was to determine the values of the image quality indicators and their relationship with the dose in mammography of screen-film that they allowed the detection of a bigger number of objects in the images obtained with the mannequin (phantom) authorized of the ACR/FDA. The study was carried out in four mammography services in a period of 12 months. The indicators of the image quality are the half optic density (DOM), contrast (differences of densities), the number of observed objects in the images and the dose for image. The minimum acceptable values by the ACR/FDA are a half optical density of 1.4, contrast of 0.4 and the one numbers minimum of objects observed in the image of the mannequin of mammography of 10 (4 fibers, 3 groups of calcifications and 3 masses), with a maximum dose by image of 3 mGy. The found results are half optical density of 1.9, contrast of 0.56 and the average number of objects observed in the images of 12, with a dose in the interval of 1.6 mGy to 2.4 mGy. The doses were measured by thermoluminescent dosimetry and ionization chamber. Once carried out the analysis of the tendencies of the indicators of image quality and their distributions is found that for a p < 0.05, the bigger number of objects observed in the images is in the interval from 1.8 to 1.9 of DOM. When comparing both mammography system, the system screen-film has a lower variability in the distribution of objects associated to a DOM. (Author)

  12. Development of a program for calculation of second dose and securities in brachytherapy high dose rate; Elaboracion de un programa para el segundo calculo de la dosis y seguridades en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Esteve Sanchez, S.; Martinez Albaladejo, M.; Garcia Fuentes, J. D.; Bejar Navarro, M. J.; Capuz Suarez, B.; Moris de Pablos, R.; Colmenares Fernandez, R.

    2015-07-01

    We assessed the reliability of the program with 80 patients in the usual points of prescription of each pathology. The average error of the calculation points is less than 0.3% in 95% of cases, finding the major differences in the axes of the applicators (maximum error -0.798%). The program has proved effective previously testing him with erroneous dosimetry. Thanks to the implementation of this program is achieved by the calculation of the dose and part of the process of quality assurance program in a few minutes, highlighting the case of HDR prostate due to having a limited time. Having separate data sheet allows each institution to its protocols modify parameters. (Author)

  13. Reference values in indicators of patient dose; Valores de referencia en los indicadores de dosis a paciente

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Llorente, P. L.; Hernandez Rodriguez, J.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Fernandez Bordes, M.; Martin Rincon, C.; Montes fuentes, C.; Garcia Repiso, S.; Sena Espinel, E. de; Martin Nunoz, J.

    2011-07-01

    The RD 1976/1999 on Quality Assurance in Diagnostic Radiology laid the foundation for developing the Radiological Protection of Patient compliance with the relevant Directive EURATOM. More than ten years of implementation, we consider an urgent review and update its content due to the legal implications involved as set forth therein, especially in the aspects that have to do with the measurement of patient dose indicators, and more specifically in exploration called complex and CAT.

  14. Effects of X-rays spectrum on the dose; Efectos del espectro de rayos X sobre la dosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez I, J. L.; Hernandez A, P. L.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Rivera M, T., E-mail: johann_greenday@hotmail.com [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    The X-ray equipment for diagnosis comes in different sizes and shapes depending on the scan type to perform. The X-ray spectrum is the energy distribution of the beam photons and consists of a continuous spectrum of photons braking and discrete spectrum due to the characteristic photons. The knowledge of the X-rays spectrum is important to understand like they affect the voltage changes (k Vp), current (m A), time (s) and the type of filter in the interaction mechanisms between X-rays and patient's body, the image receptor or other material that gets in the beam. Across the spectrum can be estimated the absorbed dose in any point of the patient, the quality of the image and the scattered radiation (which is related to the dose received by the equipment operator). The Monte Carlo method was used by MCNP5 code to calculate the spectrum of X-rays that occurs when a monoenergetic electron beam of 250 keV interact with targets of Mo, Rh and W. The spectra were calculated with and without filter, and the values of ambient dose equivalent were estimated, as well as the air kerma. (Author)

  15. Doses optimization to patients in computed tomography studies; Optimizacion de las dosis a pacientes en estudios de tomografia computada

    Energy Technology Data Exchange (ETDEWEB)

    Trujillo Z, F. E., E-mail: flaviotrujillo@gmail.co [Hospital Regional de Alta Especialidad de Oaxaca, Aldama s/n, Paraje El Tule, 71256 San Bartolo Coyotepec, Oaxaca (Mexico)

    2010-09-15

    in recent years the number of studies of computed tomography has been increased, as well as the technology and methodology of these, while the radiological protection to the patient has not advanced to the same step. The IAEA has implemented the Patients Radiation Protection projects, where one of the areas of more interest is the computed tomography. The present work is a brief summary of the actions to realize for the doses optimization imparted to the patients, obtaining an appropriate diagnostic quality in the images at the same time; as it was presented in the course of the project C-RLA/9/067-001. The results that were obtained between Image Quality and Dose by Radiation that is imparted to the patient are shown, as well s the exposition factors that influence in these, according to the project C-RLA/9/067-001. The main actions for the dose optimization are using tension optimized protocols (kV), of load (m As), of collimation/cut thickness, of inclination of the gantry, of the pitch/displacement by rotation, of the reconstruction algorithm (kernel), according to the diagnostic objective to reach and to the patient physical characteristics (like weight and age), as well as to use protections to shield the sensitive organs (mainly those that do not have clinical interest for the procedure). Conclusion: To establish or to begin to implement, insofar as possible, the IAEA recommendations, relating to the clinical practice of the hospitals in Mexico and to the available equipment s type. (Author)

  16. Dose levels in the hot cells area ININ; Niveles de dosis en el area de celdas calientes-ININ

    Energy Technology Data Exchange (ETDEWEB)

    Torre, J. De la; Ramirez, J.M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Solis, M.L. [UAEM, Toluca, Estado de Mexico (Mexico)]. E-mail: jto@nuclear.inin.mx

    2004-07-01

    The Laboratory of Hot Cells (LCC) located in the National Institute of Nuclear Research (ININ) is an institution, it is an area where radioactive material is managed with different activity values, in function of its original design for 10,000 curies of Co-60. Managing this materials in the installation, it implies to measure and to analyze the dose levels that the POE will receive as well as the implementation of appropriate measures of radiological protection and radiological safety, so that that is completed settled down by the concept ALARA. In this work they are carried out mensurations of the levels of the dose to receive for the POE when managing radionuclides with maximum activities that can be allowed in function of the current conditions of the cells and an evaluation of the obtained results is made comparing them with the effective international norms as well as the application of the program of surveillance and radiological protection implemented for the development of the works that are carry out in the installation. (Author)

  17. Evaluation of the enter surface dose, dose in organ and E effective dose, received by personnel and patients in studies of endoscopic retrograde cholangeopancreatography in the General Hospital of Mexico; Evaluacion de la dosis de entrada superficie, dosis en organo y dosis efectiva E, recibidas por personal y pacientes en estudios de colangiopancreatografia retrograda endoscopica en el Hospital General de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, S; Gama T, G [Calidad XXI SA de CV, Zacatecas 67-007 Col. Roma, 06700 Mexico D.F. (Mexico); Beristain, M; Espino, H [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Mexico D.F. (Mexico)

    2006-07-01

    The ESD for patient and personal is measured: gastroenterologuist endoscopist G1, A1 Assistant and A2 instrumentist that carried out 22 independent therapeutic procedures of CPRE, in a fluoroscopy equipment Toshiba trademark with tube under the table, operated in automatic exposure mode, CAE to average tensions of 80 kVp. The measurement is carried out with film dosemeters of double emulsion Kodak Type 2 trademark, calibrated in terms of H{sup *} for the energy of the {sup 137} Cs, first it is determined the films sensitivity like function of the optical density DO, and second the ESD for the effective energy of the radiation beam (50 keV), in three different points from the dosemeter (C, D and H). The films was placed for the personnel in: right hand, front (eye), thyroid and thorax (under D and out F of the lead apron); in the case of the patient three positions were used: thorax, hepatic region and pelvis. The mean values of the ESD and it standard deviation SD in mGy units are determined by: study, personnel, film position in doctor and patient, dosemeter measurement point. The calculated doses in organ are also determined for the patient in the thorax region, liverwort and pelvis its are agreement with the NRPB SR 262 report. Finally the H{sub E} and E for medical personnel and patients are estimated demonstrating that its are not exceeded the annual dose limits for the case of the OEP. In the case of the the OEP have for the D thorax an ESD{sub max} = 0.04 mGy that one corresponds an H{sub E} = 0.02 and E = 0.01 mSv. (Author)

  18. Maduración sexual en niños con diabetes mellitus tipo 1 tratados con dosis múltiples de insulina Sexual maturation in children presenting with Type 1 diabetes mellitus treated with multiple dose of insulin.

    Directory of Open Access Journals (Sweden)

    Tania Espinosa Reyes

    2007-04-01

    Full Text Available Antes de la terapia insulínica, la menarquia y menstruaciones subsecuentes aparecían raramente en niñas con diabetes mellitus tipo 1 (DM 1 desde la infancia, y en los varones se verificaba un importante retraso puberal. El objetivo del presente trabajo es evaluar el inicio de la pubertad, y la influencia de la edad de diagnóstico de la diabetes y el grado de control metabólico, sobre el desarrollo sexual en un grupo de ninos atendidos en consultas de endocrinología pediátrica. Se realizó un estudio prospectivo no concurrente a partir de las historias clínicas de pacientes tratados con dosis múltiples de insulina, de procedencia urbana (32 varones y 28 hembras, seguidos longitudinalmente por examen clínico y determinaciones bioquímicas periódicas desde el inicio de la DM 1 hasta alcanzar su talla final. El control metabólico fue evaluado a través de la hemoglobina glicosilada (HbA1 realizada trimestralmente, y clasificado según criterios de la institución en bueno (B: 10 %. La media de la edad a la que se encontró un volumen testicular de 4 mL fue 12,5 ± 0,8 años; en las niñas el inicio del desarrollo mamario se constató a la edad promedio de 11,4 ± 1,3 años y la menarquia ocurrió a los 12,9 ± 1,2 años. Se comprobó también que 31 pacientes tuvieron un control metabólico B (51,6 %, 22 R (36,7 % y 7 M (11,7 %. Se concluye que el tratamiento con dosis múltiples de insulina tiene una influencia favorable y decisiva sobre el grado de control metabólico, lo cual hace posible un desarrollo puberal adecuado en pacientes con DM 1.Before insulin therapy, menarche and subsequent menstruation rarely appear in girls presenting Type 1 diabetes mellitus (MD 1 from childhood, and in boys a significicant pubertal retardation was confirmed. Aim of present paper is to assess onset of puberty, influence of diagnosis age of diabetes, and degree of metabolic control, on sexual development in a cohort of children seen in service of

  19. Efeitos observados com diferentes doses de morfina subaracnóidea em ratos Efectos observados con diferentes dosis de morfina subaracnoidea en ratones Effects of different spinal morphine doses in rats

    Directory of Open Access Journals (Sweden)

    Neuzimar de Souza Freire Silva

    2004-02-01

    investigar los efectos observados con diferentes dosis de morfina por via subaracnoidea. MÉTODO: Fueron estudiados cinco grupos de siete ratones, 24 horas después de la colocación de catéter subaracnoideo vía cisterna magna bajo anestesia con cetamina y xilazina por la vía muscular. El G1 recibió 10 µl de solución fisiológica; los grupos G2, G3, G4, y G5 recibieron respectivamente 0,1; 0,3; 0,5 y 1 µg de morfina en 10 µl de solución fisiológica. Los animales fueron sometidos al teste de inmersión de la cola en agua caliente en el M0 (antes de la inyección, y M15, M30, M60, M120 y M180 minutos después de la inyección. RESULTADOS: Se observó analgesia en los grupos que recibieron morfina, en diversos momentos, cuando comparados con el grupo control y con el tiempo antes de la inyección de morfina. En el G1 hubo flaqueza de las patas en 4 animales. Ocurrió agitación en M15 en el G2 y en M15 y M30 en el G3. Tremor de mandíbula fue observado en M5, M15, M30, y M60 en el G2; en el G3 fue observado en M5 y M15; en el G4, en M5 y en el G5, en M5. Prurito fue observado en M5, M15, M30 y M60 en el G2; en M5, M15, M30, M60 y M120 en el G3; en M5, M15, M30, M60, y M120 en el G4; en M5, M15, M30, M60 y M120 en el G5. Ausencia de diúresis ocurrió en M60 en el G2; en el M15, M30, M60 y M120 en el G3; en el M60 y M120 en el G4; y en el M30 y M60 en el G5. Sedación ocurrió en M15, M30 y M60 en los grupos 2, 3 y 4; y en M15, M30, M60, y M120 en el G5. Alteración respiratoria fue observada en M15, M30, M60 en el G2; en M15, M30 y M60 en el G3; en M15 y M30 en los grupos 4 y 5. CONCLUSIONES: En este estudio, todas las dosis de morfina subaracnoideas administradas provocaran efectos colaterales; y dosis menores que 1 µg promovieron analgesia de corta duración.BACKGROUND AND OBJECTIVES: Spinal morphine promotes adequate pain relief, but is not free from side effects. This study aimed at investigating the effects of different spinal morphine doses. METHODS: Five

  20. High-Dose Ionizing Radiation Photographic Dosimetry; Mesure, par des Methodes Photogra Phiques, de Doses Elevees de Rayonnements Ionisants; 0424 041e 0422 041e 0413 0420 0414 ; Dosimetria Fotografica de Dosis Elevadas de Radiaciones Ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J.; Bucina, I. [Institute for Research Production and Application of Radioisotopes Prague, Czechoslovakia (Czech Republic)

    1965-06-15

    pour la detection de doses elevees de rayonnements et compare les merites respectifs des films FOMA et ORWO pour la mesure des doses elevees. Des progres ont egalement ete faits dans la mesure de doses elevees de rayonnements, a savoir la methode du developpement freine, decrite plus loin, dans laquelle des substances du type nitrobenzimidazole et benzotriazole sont utilisees a des concentrations appropriees dans le revelateur. Dans le cas d'emulsions lentes a forte teneur en argent, cette technique permet de mesurer des expositions a des doses gamma (rayons X de haute energie) allant jusqu'a 10s r ou meme davantage, si l 'on ne demande pas d'evaluations precises dans la gamme allant jusqu' a 100 r. Le memoire decrit l ' effet de freinage des produits chimiques ajoutes aux revelateurs sur les emulsions rapides et lentes a fortes teneur en argent. On a demontre que dans les emulsions utilisees pour la mesure de doses elevees de rayonnements intenses et traitees dans le revelateur auquel des produits chimiques de freinage ont ete ajoutes, les effets des variations en fonction de l'energie et l ' affaiblissement de l'image latente influent sur la precision des mesures. En conclusion, le memoire decrit les erreurs de dosimetrie photographique des rayonnements intenses qui ont ete decelees par des methodes statistiques mathematiques a partir de travaux experimentaux. Il est egalement question de l'accroissement de l'erreur dans les valeurs correspondant aux noircissements faibles et intenses. Les auteurs ont tenu compte egalement des erreurs dues a l'etalonnage des appareils, aux variations en fonction de l'energie, a l'affaiblissement de l'image latente, au traitement chimique et a la mesure du noircissement. La presomption que la dose mesuree par le detecteur a film correspond a la dose a l'organisme entier constitue une erreur qui n'est pas prise en consideration. (author) [Spanish] Los autores describen un metodo fotografico de medicion de dosis de radiaciones

  1. Following to the occupational dose in a nuclear power plant. Second part; Seguimiento de la dosis ocupacional en una central nuclear. Segunda parte

    Energy Technology Data Exchange (ETDEWEB)

    Medrano L, M A [Gerencia de Seguridad Radiologica, Instituto Nacional de Investigaciones Nucleares, Salazar (Mexico)

    1991-07-01

    The pursuit of the occupational doses in any installation where radioactive material is managed it allows to those responsible for the radiological safety, to know those practices or places in which should focus its efforts so that the doses received by their workers are controlled and minimized. In this work another form of pursuit of the occupational doses is presented making emphasis in the practices, places and devices or teams that produce the doses to the exposed personnel to diverse radiation sources inside a typical nuclear power station.

  2. Development of DosiMap: dosimetry device for radiotherapy quality assurance

    International Nuclear Information System (INIS)

    Frelin, A.M.

    2006-10-01

    This thesis deals with the development of a new dosimetry device for the control of radiotherapy beams. This device is composed of a plane plastic scintillator which is set within a polystyrene phantom. When the 'DosiMap' is irradiated, light is produced. This light is composed of scintillation and Cerenkov radiation, and is accurately measured by a C.C.D. camera. The analysis of the light distribution enables us to deduce the dose distribution in the scintillator plan. This device has many advantages such as tissue equivalence, a good spatial resolution, and a linear response with regard to energy. It also provides immediate measurements, and as a consequence, it is a very adapted tool for clinical use. After the introduction about the basic notions of radiotherapy, the different steps of the 'DosiMap' development are exposed in this thesis. In a first time, plastic scintillators have been tested to determine the best one for this application. Then, the deconvolution of scintillation and Cerenkov radiation have been studied, because we only use scintillation to calculate the dose distribution. The camera being in the irradiation room, a lead shield has also been developed to protect the C.C.D. detector from scattered radiations. Finally, the dose calibration and the dose response of 'DosiMap' are exposed. All this work made feasible the measurement of dose distributions with a precision which turns out to be better than 2% for homogeneous photon beams. Excellent results were also obtained when modulated intensity beams are used. (author)

  3. Estimation of the average glandular dose on a team of tomosynthesis; Estimacion de la dosis glandular media en un equipo de tomosintesis

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Martinez, L. M. R.; Sanchez Jimenez, J.; Pizarro trigo, F.

    2013-07-01

    Seeking to improve the information that gives us an image of mammography the manufacturers have implemented tomosynthesis. With this method of acquisition and reconstruction of image we went from having a 2D to a 3D image image, in such a way that it reduces or eliminates the effect of overlap of tissues. The estimate of the dose, which is always a fundamental parameter in the control of quality of radiology equipment, is more in the case of mammography by the radiosensitivity of this body and the frequency of their use. The objective of this work is the determination of the mean in a team glandular dose of with tomosynthesis mammography. (Author)

  4. Toxicidad oral a 60 días del aceite de sacha inchi (Plukenetia volubilis L. y linaza (Linum usitatissimum L. y determinación de la dosis letal 50 en roedores Oral toxicity at 60-days of sacha inchi oil (Plukenetia volubilis L. and linseed (Linum usitatissimum L., and determination of lethal dose 50 in rodents

    Directory of Open Access Journals (Sweden)

    Arilmi Gorriti

    2010-09-01

    Full Text Available Objetivos. Evaluar la toxicidad oral a 60 días y determinar la dosis letal 50 (DL 50 de los aceites crudos de sacha inchi (Plukenetia volubilis L. y linaza (Linum ussitatisimum en ratas Holtzman y en ratones cepa Balb C57, respectivamente. Materiales y métodos. Para la evaluación de la toxicidad oral a dosis repetida por 60 días se utilizó 24 ratas macho Holtzman divididos en tres grupos de ocho cada uno, los grupos fueron: solución salina fisiológica 4 mL/kg (SSF, aceite de sacha inchi 0,5 mL/kg (SI05 y aceite de linaza 0,5 mL/kg (L05, durante el experimento se controló semanalmente el peso corporal y signos de toxicidad en los grupos investigados, así como colesterol total, HDL, triglicéridos, glucosa, urea, TGP y fosfatasa alcalina a los 30 y 60 días de iniciado el experimento. Para la evaluación de la DL50 se usó ratones macho cepa Balb C57 en grupos de diez animales, se administró por vía oral dosis crecientes de aceites crudos hasta alcanzar 1 mL/kg (37 g/kg; Resultados. Los parámetros séricos en las ratas indican que no existe toxicidad alguna a los 60 días y que la administración de los aceites disminuyeron los niveles de colesterol, triglicéridos e incrementaron el HDL con respecto al grupo control. La DL50 muestra que los aceites crudos de sacha inchi y linaza presentan dosis por encima de los 37 g/kg de masa corporal. Conclusiones. Los aceites de sacha inchi y linaza son inocuos a 60 días y presentan una DL50 por encima de los 37 g/kg de animal.Objectives. To evaluate the oral toxicity at 60 days and to determine the lethal dose 50 (LD 50 of raw sacha inchi (Plukenetia volubilis L. and linseed (Linum ussitatisimum oils in Holtzman rats and mice of the strain Balb C57 respectively. Materials and methods. For the evaluation of the oral toxicity of repeated doses for 60 days, 24 male Holtzman rats were used, divided in three groups of 8 each, the groups were: physiologic saline solution 4 mL/kg (FSS, sacha inchi oil

  5. Patterns of Lethality and Absorbed Dose Distributions in Mice for Monoenergetic Neutrons; Letalite et Distribution de la Dose Absorbee chez la Souris pour des Neutrons Monoenergetiques; Letal'nost' i raspredelenie pogloshchennoj dozy pri obluchenii myshej monoehnergeticheskimi neitronami; Letalidad y Distribucion de las Dosis Absorbidas por el Raton para Neutrones Monoenergeticos

    Energy Technology Data Exchange (ETDEWEB)

    Frigerio, N. A.; Jordan, D. L. [Argonne National Laboratory, Argonne, IL (United States)

    1964-03-15

    The presence of strong C, N and O resonances in the 100 to 1500 keV region has permitted the study of specific neutron-nuclide interactions as reflected in lethality, RBE maxima etc. Sixty-two {mu}A of resolved Van de Graaf protons, 1882 to 2738 keV, yielded monoenergetic neutrons via Li{sup 7}(p, n)Be{sup 7}. Virgin female CF-1 mice were exposed in celluloid capsules to the mono-energetic neutrons at distances of 3.1 to 11.3 cm from the source at laboratory angles of 0 to 1 radian. Mice were exposed bilaterally while simultaneously in motion through either circular or elliptical orbits normal to the axis of the beam. Thus, control of dose distribution within the animal was possible. Absolute flux measurements were made with U{sup 235} fission counters and by absolute counting of Au wires and foils activated within Cd covers. Patterns of dose absorption were measured with micro-ionization chambers and with a specially developed FeSO{sub 4}-NH{sub 4}SCN dosimeter of high sensitivity. Relative dose measurements were made with Hurst proton-recoil gas counters and B{sup 10} , Li{sup 6} and proton-recoil scintillators. Neutron-energy distributions were measured with specially developed B{sup 10}, He{sup 3} and Li{sup 6} gas and solid-state spectrometers. Gamma contributions were measured with Ne/Ar chamber counters. These measurements showed gamma contribution to be less than 0.8%, and thermal-epithermal less than 0.01%, of the total rad dose. Animals were exposed to median midpoint doses ranging from 180 to 1200 rad at neutron energies from 396 to 658 keV {+-} 50 keV to cover the region of N and O resonances. Levels and patterns of lethality proved to be strong functions of neutron energy and equally strong, but independent, functions of dose distribution. Regardless of dose, energy or distribution, however, all animals surviving five days survived at least 144 days, dying then of the usual long-term effects. This suggests that monoenergetic fast neutrons, free of

  6. Determinación de la distribución de dosis en tratamientos de cáncer de mama con fuentes de 192 Ir HDR / Determination of doses distributions on breast cancer treatments with 192 Ir HDR sources

    OpenAIRE

    Beltrán Gómez, Cristian Camilo

    2010-01-01

    La Braquiterapia de alta tasa de dosis HDR es una moderna técnica de tratamiento que ha venido teniendo un rápido crecimiento en su uso clínico, reemplazando a la braquiterapia de baja tasa de dosis LDR. La braquiterapia HDR se caracteriza por utilizar fuentes radiactivas con tasas de dosis mayores a 12 Gy/h, por tanto con propósitos de protección radiológica debe ser realizada con equipos de carga remota, es común en los tratamientos de braquiterapia HDR depositar altas dosis por fracción, c...

  7. Dose-response relationships determined in growing rats for various platinum compounds administered with the food. Untersuchungen zu Dosis-Wirkungsbeziehungen verschiedener alimentaer zugefuehrter Platinverbindungen bei wachsenden Ratten

    Energy Technology Data Exchange (ETDEWEB)

    Bader, R.

    1991-02-08

    Forming part of a research project entitled 'Emissions of Precious Metals', this study had the aim to describe dose-related responses that occur in growing rats following administration of platinum with the food. The oral intake of diets containing up to to 50 mg platinum/kg food had no detectable influence on the food consumption of the animals, nor were there any deviations from the normal growth curves that could be related to the addition of platinum. Comparisons with the control group pointed to a decline in erythrocytes from 5.88 {+-} 0.55 x 10{sup 6}/{mu}l to 5.11 {+-} 0.50 x 10{sup 6}/{mu}l following administration of 50 ppm PtCl{sub 4} over a period of four weeks. There were no other changes in hematological parameters that attained statistical significance. The treatment group receiving platinum amounts of 50 mg/kg with the diet showed a plasma creatinine value of 1.45 {+-} 0.19 {mu}g/dl, which significantly (p < 0.05) exceeded that of the control group, where creatinine levels remained at 0.70 {+-} 0.50 {mu}g/dl. This leads to the conclusion that the possibility of renal impairment after high oral doses of PtCl{sub 4} is not very remote. (orig./VT).

  8. The Relationship between Blood Injury and Absorbed Dose in Criticality Accidents; Relations entre la Deterioration du Sang et la Dose Absorbee lors d'Accidents Dus a la Formation d'un Etat Critique; Svyaz' mezhdu velichinoj pogloshchennoj dozy pri avariyakh na reaktorakh, dostigshikh kritichnosti, i narusheniem sostava krovi; Relacion entre las Hemolesiones y la Dosis Absorbida en los Accidentes de Criticidad

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, J. A. [Health Physics and Medical Division, Atomic Energy Research Establishment, Harwell (United Kingdom)

    1964-03-15

    The neutron and gamma doses to individuals exposed in criticality accidents have been recalculated to yield the surface-absorbed dose to the trunk of the body. The relationship is examined between this dose estimate and blood-count profile scores that are based on the scoring system of N. Wald and G. E. Thoma for deviations from the normal of the lymphocyte, neutrophil and platelet-peripheral blood counts. It is shown that a quantity based on the surface-absorbed gamma dose and the Na{sup 24} activity in the blood shows a better correlation with the blood-count profile score and is a better prognostic guide for the degree of radiation injury than any of the conventional dose estimates. The R. B. E's of the heavy-particle recoil doses deduced from these observations are consistent in general with values obtained from experiments on dogs. (author) [French] L'auteur a fait un nouveau calcul des doses de neutrons et de rayons gamma delivrees aux personnes exposees lors d'accidents due a la formation d'un etat critique, pour obtenir la dose en surface absorbee par le tronc. Il a etudie la relation entre cette estimation de la dose et la 'courbe resultante de numeration globulaire' de N. Wald et G. E. Thoma du point de vue des anomalies en lymphocytes, polynucleaires neutrophiles et plaquettes. Il montre qu'une quantite fondee sur la dose absorbee en surface de rayons gamma et l'activite de {sup 24}Na dans le sang accuse une meilleure correlation avec la courbe resultante de numeration globulaire et permet de mieux prevoir le degre de radiolesion que toute autre estimation classique de la dose. Les EBR des doses dues aux particules lourdes de recul, deduites de ces observations, concordent dans l'ensemble avec les valeurs obtenues au cours d'experiences sur des chiens. (author) [Spanish] El autor reviso sus calculos sobre las dosis de neutrones y rayos gamma en los sujetos expuestos a consecuencia de accidentes de criticidad, a fin de determinar las dosis superficiales

  9. Adaptive answer to low ionizing radiation doses in Saccharomyces cerevisiae; Respuesta adaptativa a bajas dosis de radiacion ionizante en Saccharomyces cerevisiae

    Energy Technology Data Exchange (ETDEWEB)

    Durand, Jorge L. [Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Inst. Balseiro; Frati, Diego Libkind; Broock, Maria Van [Universidad Nacional del Comahue, Bariloche (Argentina). Centro Regional Universitario Bariloche; Gillette, Victor [Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico

    2001-07-01

    The aim of this work is to verify the existence of the adaptive response phenomenon induced by low doses of ionizing radiation in living cells. It is known that low doses of ionizing radiation, called conditioning doses, may induce resistance in exposed organisms to higher doses, called challenging doses, which are applied after a period of time. The involved mechanisms in this phenomenon, called Adaptive Response, are diverse and complex. Among them, the most important are the activation of DNA-repair enzymes and nuclear recombination process. As the 'target' sample, it was utilized a 'wild type' strain of Saccharomyces cerevisiae in aqueous suspension. Adaptive Response was verified in a wide range of challenging doses. Conditioning doses, inductors of radio-resistance, were (0.44{+-}0.03) Gy and the waiting time between them and challenging doses was 2 hours at room temperature.(author)

  10. Savannah River Site dose control

    International Nuclear Information System (INIS)

    Smith, L.S.

    1992-01-01

    Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits

  11. The Let Distribution of Dose in Some Tissue Cylinders; Repartition de la Dose en Fonction du TLE dans Quelques Modeles Cylindriques de Tissus; Raspredelenie linejnoj peredachi ehnergii dozy v nekotorykh tkanevykh tsilindrakh; Distribucion de la Dosis en Funcion de la TLE en Algunos Modelos Cilindricos de Tejidos

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, W. S. [Oak Ridge National Laboratory Oak Ridge, TN (United States)

    1964-03-15

    spectre de la dose delivree par des faisceaux de neutrons monoenergetiques a des modeles cylindriques de tissus simulant une souris, un rat, un cobaye, un chien et un homme. On a admis que ces tissus consistaient en H, C, N et C dans les memes proportions que pour l'homme standard. Les sections efficaces de H etaient sensiblement identiques a celles qui sont donnees dans BNL-325 et les sections efficaces de 0 ,N et C ont ete reprises de NDA 2111-3 (volume A ), ORNL-2389 et NDA 12-16, respectivement. On a calcule egalement le cas d'un modele irradie par le spectre de fission modifie utilise par Neary. Les valeurs ainsi obtenues de la repartition de la dose en fonction du TLE, associees aux valeurs de l'EBR recommandees par la CIPR, permettent d'interpreter les effets biologiques de l'exposition aux neutrons. Ces valeurs ont ete comparees aux donnees sur les effets biologiques des neutrons obtenues a la suite de certaines experiences; elles confirment, du moins en partie, les hypotheses generalement admises sur la relation fonctionnelle entre l'EBR et le TLE, par exemple que la possibilite de guerison et l'effet d'oxygene se manifestent essentiellement par les doses a faible TLE. Bien que ces interpretations revetent encore un caractere preliminaire, la repartition de la dose en fonction du TLE pourra servir de base a de nouvelles experiences sur la relation entre l'EBR et le TLE. (author) [Spanish] Cuando un modelo de tejido se expone a neutrones, los nucleos de retroceso formados presentan un espectro energetico continao. Aun en el caso de los neutrones monoenergeticos, se observaran distribuciones continuas de energia para los distintos nucleos de retroceso y, por lo tanto, tambien sera continua la distribucion de la dosis en funcion de la TLE. Utilizando un programa tipo Montecarlo en la calculadora 'Controlled Data 1604', el autor calculo, en funcion de la TLE, el espectro de la dosis proporcionada por haces monoenergeticos'de neutrones a modelos cilindricos de tejidos

  12. Determinación cromatográfica de misoprostol a dosis baja en plasma neonatal y calostro materno Chromatographic determination of misoprostol at a low dose in neonatal plasm and mother colostrum

    Directory of Open Access Journals (Sweden)

    Danilo Nápoles Méndez

    2011-05-01

    Full Text Available Se efectuó un estudio de cromatografía con el objetivo de realizar un análisis cualitativo que definiera un rango de seguridad; demostrar la presencia o no del misoprostol en sangre neonatal o calostro materno cuando se emplea a bajas dosis (25 microgramos por vía vaginal, en pacientes con distocia de fase latente del trabajo de parto, así como determinar la presencia de complicaciones en el recién nacido. Las muestras fueron analizadas en 2 momentos entre 2008 y 2009, previa coordinación del Hospital Ginecoobstétrico "Mariana Grajales Coello" de Santiago de Cuba con el Centro de Biofísica Médica de la Universidad de Oriente y el Centro Nacional de Toxicología en Ciudad de La Habana, si bien la investigación formó parte de un ensayo clínico en fase III, donde se empleó el misoprostol en 327 gestantes. Para la cromatografía se escogieron 50 muestras de plasma neonatal y 50 de calostro materno, de pacientes que parieron en las primeras 6 horas de la última dosis del medicamento, cuando supuestamente existe actividad plasmática. Los recién nacidos fueron observados clínicamente durante 72 horas, en cuyo intervalo se les indicaron pruebas de laboratorio para precisar posibles complicaciones, pero estas no se produjeron; tampoco resultó posible cuantificar señales en los tiempos de retención esperados para los derivados y el principio activo del misoprostol. Se concluyó que en las condiciones de administración establecidas en la casuística, los datos cromatográficos obtenidos muestran que la dosis empleada es segura para el neonato.A chromatography study was conducted with the aim of a qualitative analysis to define a range of safety, demonstrate the presence or absence of misoprostol in neonatal blood or mother colostrum when used at low doses (25 micrograms vaginally in patients with dystocia in latent stage of labor, as well as to determine the presence of complications in the newborn. The samples were analyzed in 2

  13. Dose budget for exposure control

    International Nuclear Information System (INIS)

    Nair, P.S.

    1999-01-01

    Dose budget is an important management tool to effectively control the collective dose incurred in a nuclear facility. The budget represents a set of yardsticks or guidelines for use in controlling the internal activities, involving radiation exposure in the organisation. The management, through budget can evaluate the radiation protection performance at every level of the organisation where a number of independent functional groups work on routine and non-routine jobs. The discrepancy between the plan and the actual performance is high lighted through the budgets. The organisation may have to change the course of its operation in a particular area or revise its plan with due focus on appropriate protective measures. (author)

  14. Measurement of effective dose in clinic radiation diagnosis with TL dosimeters developed in Mexico; Medicion de dosis efectiva en radiodiagnostico clinico con dosimetros TL desarrollados en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Martinez, Pedro R. [Instituto Nacional de Investigaciones Nucleares, Mexico, D.F. (Mexico); Azorin Nieto, Juan [Universidad Autonoma Metropolitana-Iztapalapa, Mexico D.F. (Mexico); Gonzalez Urquidi, Blanca [Universidad Veracruzana, Xalapa (Mexico); Maldonado Sanchez, Guadalupe [Instituto Mexicano del Seguro Social (IMSS), Toluca (Mexico). Hospital de Gineco Obstetricia

    2001-07-01

    At the moment the radiation diagnosis is one of the main causes of exposition to the ionizing radiations, and in many of the cases the limits to the limits of dose established by the Commission the International of Radiological safety are not applied. In this work the results obtained in the measurement of the effective dose with dosemeters Tl of LiF:Mg,Cu, P+PTFE developed in the National Institute of Nuclear Investigations (ININ), in patients to studies of clinical radiation diagnosis of urography and hysterosalpingography. The effective dose was considered in gonads, breasts and thyroid. Whereas in the radiologist physician the dose was measured in crystalline, thyroid and hands, in this work ware made whole body measurements in addition. The results showed that the dose received by patients is equivalent with the results reported in Literature; in the case of the radiologist physician, the dose considered in the made studies is below the limits recommended for POE.

  15. Coincidence in the dose estimation in a OEP by different methods; Coincidencia en la estimacion de dosis en un POE por diferentes metodos

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Arceo M, C.; Brena V, M. [ININ, Km. 36.5, Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: cgc@nuclear.inin.mx

    2007-07-01

    The case of an apparent overexposure to radiation according to that indicated for the thermoluminescent dosemeter 81.59 mSv (TLD) of a occupationally exposed hard-working (POE), for that was practiced the study of biological dosimetry. The estimated dose was 0.12 Gy with which was proven the marked dose registration by the TLD dosemeter. It was concluded that both doses are the same ones. (Author)

  16. Determination of effective dose in pediatric radiodiagnostic in Medellin-Colombia; Determinacion de la dosis efectiva en radiodiagnostico pediatrico en Medellin-Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Garzon, William J., E-mail: wjaramig@gmail.com [Instituto Tecnologico Metropolitano (ITM), Medellin (Colombia); Aramburo, Javier M.; Jimenez, Angelmiro A.; Ortiz, Anselmo P., E-mail: jmorales@unal.edu.co, E-mail: aarrieta@unal.edu.co, E-mail: japuerta@unal.edu.co [Universidad Nacional de Colombia (UNAL), Medellin (Colombia)

    2013-10-01

    In order to know the effective dose in pediatric X-ray exams of chest, entrance surface dose measurements were performed for ages 1,5 and 10 years in the largest pediatric hospital in the city of Medellin, Colombia. The effective dose was obtained from applying the conversion coefficients to measures of the entrance surface dose (ESD) in 306 radiographic studies in AP and LAT I projections. The results were validated with PCXMC 2.0 computer program and other work reported in the literature. (author)

  17. Doses in pediatric urinary studies guided by fluoroscopy: methodology oriented to the education; Dosis en estudios urinarios pediatricos guiados por fluoroscopia: metodologia orientada a la educacion

    Energy Technology Data Exchange (ETDEWEB)

    Cotelo, E; Castillo, C; Padilla, M [Escuela Universitaria de Tecnologia Medica, Facultad de Medicina, Universidad de la Republica (UdelaR) Av. Italia s/n 3er. piso CP 11600, Montevideo (Uruguay); Rabin, C [Instituto de Fisica, Facultad de Ciencias, UdelaR, Montevideo (Uruguay)

    2006-07-01

    The challenge of the Radiological Protection (RP) it is to implement Programs of Quality Guarantee without limiting them to the quality control. Radiologists and technicians should to familiarize with the dosimetry of patient, and the specialists in RP need to have clinical practice. The children (more radiosensitive that the adults) they present difficulties own to establish clinical approaches of quality due to their variations anthropomorphic (wide age range) and to specific illnesses. Also, those studies guided by fluoroscopy are of difficult standardization by the numerous ones pathologies (with anatomic-physiologic variations). It was determined the Kerma Area Product (P{sub K,A} ) in 25 subjected patients to cystourethrographies carried out by the same radiologist doctor. Its were registered anthropometric data, technical parameters, irradiated area, number radiographs, P{sub K,A} , pathologies. The complications (collaboration, delays in urinating), the radiological protocols and the learning curve of the radiologist were analyzed. When knowing the 'in situ' dose, the radiologist could relate it with those variables that determine it, optimizing immediately it practice. The hope wide range of obtained P{sub K,A} (0.17 - 1.85) Gy.cm{sup 2} deepened the analysis. The measurement of P{sub K,A} (non mandatory in all Latin America) it constitutes an incomparable educational tool in RP, should be used, at least, in reference hospitals. (Author)

  18. Doses in pediatric urinary studies guided by fluoroscopy: methodology oriented to the education; Dosis en estudios urinarios pediatricos guiados por fluoroscopia: metodologia orientada a la educacion

    Energy Technology Data Exchange (ETDEWEB)

    Cotelo, E.; Castillo, C.; Padilla, M. [Escuela Universitaria de Tecnologia Medica, Facultad de Medicina, Universidad de la Republica (UdelaR) Av. Italia s/n 3er. piso CP 11600, Montevideo (Uruguay); Rabin, C. [Instituto de Fisica, Facultad de Ciencias, UdelaR, Montevideo (Uruguay)]. e-mail: elecote@adinet.com.uy

    2006-07-01

    The challenge of the Radiological Protection (RP) it is to implement Programs of Quality Guarantee without limiting them to the quality control. Radiologists and technicians should to familiarize with the dosimetry of patient, and the specialists in RP need to have clinical practice. The children (more radiosensitive that the adults) they present difficulties own to establish clinical approaches of quality due to their variations anthropomorphic (wide age range) and to specific illnesses. Also, those studies guided by fluoroscopy are of difficult standardization by the numerous ones pathologies (with anatomic-physiologic variations). It was determined the Kerma Area Product (P{sub K,A} ) in 25 subjected patients to cystourethrographies carried out by the same radiologist doctor. Its were registered anthropometric data, technical parameters, irradiated area, number radiographs, P{sub K,A} , pathologies. The complications (collaboration, delays in urinating), the radiological protocols and the learning curve of the radiologist were analyzed. When knowing the 'in situ' dose, the radiologist could relate it with those variables that determine it, optimizing immediately it practice. The hope wide range of obtained P{sub K,A} (0.17 - 1.85) Gy.cm{sup 2} deepened the analysis. The measurement of P{sub K,A} (non mandatory in all Latin America) it constitutes an incomparable educational tool in RP, should be used, at least, in reference hospitals. (Author)

  19. National bank of occupational Doses of the Cuba Republic: main results and experiences; Banco Nacional de Dosis ocupacionales de la Republica de Cuba: principales resultados y experiencias

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Ramos, M.; Prendes Alonso, M.; Tomas Zerquera, J.; Molina Perez, D.; Soler Castro, A., E-mail: zury@cphr.edu.cu [Agencia de Energia Nuclear y Tecnologias de Avanzada (CPHR/AENTA), La Habana (Cuba). Centro de Proteccion e Higiene de las Radiaciones; De la Fuentes Puch, A. [Centro Nacional de Seguridad Nuclear (CNSN), La Habana (Cuba)

    2013-11-01

    The general objective of the development of the National Bank of Dose was to contribute for improving security monitoring in applications, by providing Cuban Regulatory Authority an effective tool to comply with the requirements that the records of individual occupational doses of Cuban workers are retained and available for competent authorities and individuals.

  20. Proposition for restriction dose levels for occupational exposition in medical practices; Propuesta de niveles de restriccion de dosis para la exposicion ocupacional en las practicas medicas

    Energy Technology Data Exchange (ETDEWEB)

    Callis, Ernesto; Cornejo, Nestor; Lopez, Gladys; Capote, Eduardo; Diaz Bernal, Efren [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba)]. E-mail: ernesto@cphr.edu.cu; Domenech, Haydee

    2001-07-01

    A study was carried out in order to propose restriction levels for occupational exposures in nuclear medicine and teletherapy. The initial data were the annual doses of occupational exposed workers reported by external dosimetry of 23 institutions since 1990 to 1999, which were analyzed by statistical processing to obtain the variation ranges of this magnitude. Dose values corresponding to the 75-percentile were then considered in this study. Simultaneously, a model of the exposure scenarios was used for the estimation of the annual effective doses, this estimation was supported with measurements of dose rates carried out in the institutions. The restriction levels were obtained by multiplying the sum of the annual doses (normal and potential) by a reserve coefficient defined in the present work. The determined restriction levels are in the range of those obtained by other similar studies. (author)

  1. Determination of effective dose for workers hemodynamics service using double dosimetry; Determinacion de la dosis efectiva para los trabajadores del servicio de hemodinamica usando doble dosimetria

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Lopez, M. A.; Lobato Munoz, M.; Jodar Lopez, C. A.; Ramirez Ros, J. C.; Jerez Sainz, M. I.; Pamos Urena, M.; Carrasco Rodriguez, J. L.

    2013-07-01

    The use of an additional dosimeter at the level of the neck above the lead apron we can provide an indication of the dose in the head (the Crystal dose). In addition, it is possible to combine the two readings of the dosimeter to provide an improved estimate of the effective dose. In the hemodynamics service of our Hospital we have maintained a worker for 3 years with the double dosimetry read monthly. With the readings from these dosimeters will do following algorithms, several estimates of the effective dose to see if, with working conditions that occur in this service, it would be necessary to extend this practice to the rest of the workers to get a better estimation of effective dose. (Author)

  2. Dose response curve of induction of MN in lymphocytes for energies Cs-137; Curva dosis respuesta de induccion de micronucleos en linfocitos para las energias Cs-137

    Energy Technology Data Exchange (ETDEWEB)

    Serna Berna, A.; Alcaraz, M.; Acevedo, C.; Vicente, V.; Fuente, I. de la; Canteras, M.

    2006-07-01

    The determination of the dose-response curve is a crucial step to use the Micronucleus assay in Lymphocytes as a biological dosimeters. The most widely used fitting function is the linear-quadratic function. The coefficients are fitted by calibration data provided by irradiations of blood from healthy donors. In our case we performed the calibration curve corresponding to gamma radiation from Cesium-137 (660 keV). Doses ranged from 0 to 16 Gy. The fitting procedure used was the iteratively re weighted least square algorithm implemented in a Matlab routine. The results of the analysis of our data show that the dose-effect curve does not follow a linear-quadratic curve at high radiation doses, diminishing the quadratic parameters as dose increases. This can be interpreted as a micronucleus saturation effect beyond a certain dose level. We conclude that the MN assay with lymphocytes can be well characterized as a biological dosimeters up to a maximum dose of 4.5 Gy. (Author)

  3. Analysis of dose to crystalline in Interventional radiology: a purpose of one case; Analisis de dosis a cristalino en Radiologia intervencionista: a proposito de un caso

    Energy Technology Data Exchange (ETDEWEB)

    Carrera M, F.; Moreno R, F.; Velazquez M, F.; Manzano M, F.J.; Moreno S, T. [Hospital `Juan Ramon Jimenez` Ronda Norte s/n 21005. Huelva, Espana (Spain)

    1998-12-31

    The present work shows the dose values to crystalline for the personnel which works in interventional radiology procedures. It was took data of 436 studies with a total of 2,133.4 minutes in fluoroscopy and 19,563 images. It was showed dose values to crystalline in three situations: without blinding, with blinding of 0.25 and 0.50 mm Pb and by type of study: fluoroscopy, graphie and total. The dose means and ranges to patient for each of these studies also are detailed. (Author)

  4. Systems automated reporting of patient dose in digital radiology; Sistema automatizado para generacion de informes de dosis a paciente en radiologia digital

    Energy Technology Data Exchange (ETDEWEB)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-07-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  5. Image and dose quality in selected studies of conventional radiology in designed hospitals; Calidad de imagen y dosis en estudios seleccionados de radiologia convencional en hospitales designados

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas H, J.; Martinez G, A. [CPHR, Calle 20 No. 4113 e/41 y 47 Playa, C.P. 11300 La Habana (Cuba); Machado T, A.; Mora M, R. de la [Centro de Control Estatal de Equipos Medicos (Cuba); Pedroso, L. [Grupo Asesor del Ministerio de Salud Publica en materia de radiologia (Cuba); Villa Z, R. [Programa de Seguridad Radiologica del Ministerio de Salud Publica (Cuba); Sotolongo C, J.A.; Rodriguez S, R.M. [Hospital Universitario Clinico Quirurgico ' Luis Diaz Soto' (Cuba); Martinez A, U.; Figueroa G, L.M. [Hospital Universitario Clinico Quirurgico ' Miguel Enriquez' (Cuba)]. e-mail: cardenas@cphr.edu.cu

    2006-07-01

    The medical exposures have a significant contribution to the received doses by the population. As they generally contribute to the patient's direct benefit during a lot of time has been paid smaller attention that to other exposure forms, in spite of existing potentialities of reducing dose to the patients as consequence of these applications. In such sense in the last years the scientific community and international organizations have defined requirements to contribute to that the doses to the patients are the minimum ones necessary to achieve its diagnostic objective. The work exposes the results obtained in the evaluation of the image quality and dose in studies of radiology of thorax posteroanterior and of lumbosacral column anteroposterior and lateral, carried out in 2 university hospitals of La Havana, as well as the contribution of this investigation to the establishment of guidance levels in our country. (Author)

  6. Glandular dose in breast tomosynthesis examinations: Preliminary study with a sample of patients; Dosis glandular en examenes de tomosintesis de mama: estudio preliminar con una muestra de pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, M.; Chevalier, M.; Calzado, A.; Valverde, J.

    2013-07-01

    The aim of this study is to analyze the mean glandular dose administered to a group of patients with a tomography system (Selenia Dimensions) service installed on a large hospital in which routine tests are done and screening. (Author)

  7. Paradigm shift in LUNG SBRT dose calculation associated with Heterogeneity correction; Cambio de paradigma en SBRT pulmonar asociada al calculo de dosis con correccion de heterogeneidad

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrilla, J.; Pinto Monedero, M.; Marti Asensjo, J.; Alonso Iracheta, L.

    2015-07-01

    Treatment of lung injury SBRT requires great dosimetric accuracy, the increasing clinical importance of dose calculation heterogeneities introducing algorithms that adequately model the transport of particles narrow beams in media of low density, as with Monte Carlo calculation. (Author)

  8. Comparative analysis of dose levels to patients in radiological procedures guided by fluoroscopy; Analisis comparativo de los niveles de dosis a paciente en procedimientos radiologicos guiados por fluoroscopia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Pablo Luis; Fernandez, Manuel; Ramos, Julio A.; Delgado, Jose Miguel; Cons, Nestor, E-mail: pablogll@eresmas.com [Hospital Universitario de Salamanca (Spain). Servicio de Radio fisica y Proteccion Radiologica

    2013-07-01

    This work presents the comparative data of the dose indicators for patient in radiological processes with respect to the values published in the ICRP document. It is analyzed the need for different strategies to communicate to different specialists mechanisms to optimize the radiation beginning with practice by training of second degree level in radiological protection and then, working with them the basics of equipment management to reduce doses without detriment to the welfare purpose.

  9. Determination of the dose index in computerized tomography using thermoluminescent dosemeters; Determinacion del indice de dosis en tomografia computada usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Azorin, J.C.; Calderon, A. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-IPN, 11500 Mexico D.F. (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  10. Commercial sugar, an alternative dosemeter for the dose determination in radiological emergency conditions; Azucar comercial, un dosimetro alternativo para la determinacion de dosis en situaciones de emergencia radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Urena N, F.; Galindo, S. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    It was carried out the dosimetric evaluation of commercial sugar, with the purpose to determine the feasibility to be able to use this type of substance as a dosimetric material in cases to present some radiological emergency cases. The studied parameters using the Electron Paramagnetic Resonance (EPR) technique were: pre-doses signal or depth signal, dose-response stability, reproducibility, reliability and signal clearing decreasing. (Author)

  11. Doses determination in UCCA treatments with LDR brachytherapy using Monte Carlo methods; Determinacion de dosis en tratamientos de CaCU con braquiterapia LDR usando metodos Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Comite de Investigacion, Calz. de la Cruz 118 sur, 63000 Tepic, Nayarit (Mexico); Vega C, H. R., E-mail: neutronesrapidos@gmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2017-10-15

    Using Monte Carlo methods, with the code MCNP5, a gynecological mannequin and a vaginal cylinder were modeled. The spatial distribution of absorbed dose rate in uterine cervical cancer (UCCA) treatments was determined under the modality of manual brachytherapy of low dose rate (B-LDR). The design of the model included the gynecological liquid water mannequin, a vaginal cylinder applicator of Lucite (PMMA) with hemisphere termination. The applicator was formed by a vaginal cylinder 10.3 cm long and 2 cm in diameter. This cylinder was mounted on a stainless steel tube 15.2 cm long by 0.6 cm in diameter. A linear array of four radioactive sources of Cesium 137 was inserted into the tube. 13 water cells of 0.5 cm in diameter were modeled around the vaginal cylinder and the absorbed dose was calculated in these. The distribution of the fluence of gamma photons in the mesh was calculated. It was found that the distribution of the absorbed dose is symmetric for cells located in the upper and lower part of the vaginal cylinder. The values of the absorbed dose rate were estimated for the date of manufacture of the sources. This result allows the use of the law of radioactive decay to determine the dose rate at any date of a gynecological treatment of B-LDR. (Author)

  12. Estimate of the dose received in crystalline lens by pediatric interventional cardiologists; Estimacion de la dosis recibida en cristalino por cardiologos intervencionistas pediatricos

    Energy Technology Data Exchange (ETDEWEB)

    Koren, C.; Alejo, L.; Serrada, A., E-mail: cristina.koren@salud.madrid.org [Hospital Universitario La Paz, Servicio de Radiofisica y Radioproteccion, Paseo de la Castellana 261, 28046 Madrid (Spain)

    2014-08-15

    The objective of this work is to estimate the maximum dose accumulated during one year in the crystalline lens of the pediatric interventional cardiologists that work in the Hospital Universitario La Paz. Optically Stimulated Luminescence Dosimeters (OSLDs) were used for to carry out this estimation, placed in the eyes of an anthropomorphic mannequin whose position in the room simulates the more habitual conditions of the clinical practice. Previously to the simulation, different tests to validate the used dosimetric system were realized, including those related with the stability, reproducibility and lector linearity, as well as the angular and energy dependence of the OSLDs. During the simulation the mannequin eyes were irradiated and were measured with OSLDs the rate of superficial equivalent dose in crystalline lens for the different qualities of beam habitually used, as much in fluoroscopy as in acquisition. With the obtained data during three years, corresponding to the fluoroscopy times and the acquisitions number of the interventional procedures carried out; as much therapeutic as diagnostic, and rate by measuring of obtained dose, has been considered the superficial equivalent dose and the equivalent dose at 3 mm deep accumulated in the crystalline lens of the pediatric interventional cardiologist with more work load of the Hospital, during the years 2011 and 2012. None of the obtained maximum values exceed the new dose annual limit in crystalline lens of 20 mSv, recommended by ICRP in April of 2011. (author)

  13. Usefulness of recombinant human TSH-aided radioiodine doses administered in patients with differentiated thyroid carcinoma Administración de dosis terapéuticas de radioyodo luego de TSH recombinante en pacientes con carcinoma diferenciado de tiroides

    Directory of Open Access Journals (Sweden)

    Fabián Pitoia

    2006-04-01

    Full Text Available The published studies confirming the safety and efficacy of rhTSH for diagnostic purposes have led to an increased interest in its use for preparation for radioiodine (RI dose administration in patients with recurrent or persistent differentiated thyroid carcinoma (DTC. In order to establish the efficacy of RI therapy after rhTSH, we have reviewed 39 rhTSH-aided radioiodine treatment in a series of 28 DTC patients. Patients were divided into two groups: GI (n=17, with previous thyroid bed uptake and undetectable thyroglobulin (Tg levels under levothyroxine treatment and GII (n=11, with proven metastatic local or distant disease. Median follow-up after the first rhTSH-aided radioiodine treatment was 32 ± 13 months (range 8 to 54 months. Sixteen patients (94% in GI were rendered disease free and one patient was shown to have persistent disease. In GII, the post therapy whole body scan showed pathological uptakes in all cases: in four patients in lungs, in four in mediastinum and in three in lateral neck. In two patients with mediastinum uptake, Tg levels were undetectable after rhTSH. In the follow-up, two patients with lateral neck uptake were rendered disease free, four patients died (three due to thyroid cancer and five out of the remaining patients have persistent disease. In conclusion, rhTSH aided therapy was helpful to eliminate normal thyroid bed remnants in 16/17 (94% patients (GI. rhTSH stimulated Tg was undetectable in two patients with mediastinal metastasis. We believe that rhTSH is a good alternative to levothyroxine withdrawal for the treatment of DTC with radioactive iodine, increasing the quality of life in these patients. Caution should be recommended in the follow-up of unselected DTC patients only with stimulated Tg levels.Los estudios publicados que confirman la seguridad y eficacia de la TSH recombinante (rhTSH llevaron a un incremento en el interés para su uso como adyuvante terapéutico en el CDT (ablación o tratamiento

  14. Dose verification by OSLDs in the irradiation of cell cultures; Verificacion de dosis mediante OSLDs, en la irradiacion de cultivos celulares

    Energy Technology Data Exchange (ETDEWEB)

    Meca C, E. A.; Bourel, V. [Ce. De. Te. Centro Especializado en Terapia Radiante, Viamonte 1861, C1056 Buenos Aires (Argentina); Notcovich, C.; Duran, H., E-mail: edarmeca@gmail.com [Comision Nacional de Energia Atomica, Departamento de Micro y Nanotecnologia, Av. Gral. Paz 1499, 1650 San Martin, Buenos Aires (Argentina)

    2015-10-15

    The determination of value of irradiation dose presents difficulties when targets are irradiated located in regions where electronic equilibrium of charged particle is not reached, as in the case of irradiation -in vitro- of cell lines monolayer-cultured, in culture dishes or flasks covered with culture medium. The present study aimed to implement a methodology for dose verification in irradiation of cells in culture media by optically stimulated luminescence dosimetry (OSLD). For the determination of the absorbed dose in terms of cell proliferation OSL dosimeters of aluminum oxide doped with carbon (Al{sub 2}O{sub 3}:C) were used, which were calibrated to the irradiation conditions of culture medium and at doses that ranged from 0.1 to 15 Gy obtained with a linear accelerator of 6 MV photons. Intercomparison measurements were performed with an ionization chamber of 6 cm{sup 3}. Different geometries were evaluated by varying the thicknesses of solid water, air and cell culture medium. The results showed deviations below 2.2% when compared with the obtained doses of OSLDs and planning system used. Also deviations were observed below 3.4% by eccentric points of the irradiation plane, finding homogeneous dose distribution. Uncertainty in the readings was less than 2%. The proposed methodology contributes a contribution in the dose verification in this type of irradiations, eliminating from the calculation uncertainties, potential errors in settling irradiation or possible equipment failure with which is radiating. It also provides certainty about the survival curves to be plotted with the experimental data. (Author)

  15. Absorbed doses received by infants subjected to panoramic dental and cephalic radiographs; Dosis absorbida recibida por infantes sometidos a radiografias dentales panoramicas y cefalicas

    Energy Technology Data Exchange (ETDEWEB)

    Carrizales, L.; Carreno, S. [Instituto Venezolano de Investigaciones Cientificas. Laboratorio Secundario de Calibracion Dosimetrica. Carretera Panamericana Km. 11. Apartado Postal 21827, Caracas (Venezuela)

    1998-12-31

    The IAEA Report No. 115 recommends that each country or region can establish levels of absorbed doses for each radiographic technique employed in diagnostic. assuming the extended and expensive of this purpose, we have been to begin in a first step with the dentistry area, in order to estimate the dose levels received at crystalline and thyroid level in infants that go to an important public institution in our country to realize panoramic and cephalic radiographs. This work will serve to justify and impel a quality assurance program in Venezuela on the dentistry area which includes aspects such as training for the medical lap referring the justification of the radiological practice, optimization of X-ray units to produce an adequate image quality that delivers to patient an absorbed dose as much lower as reasonably it can be reached without diagnostic detriment. (Author)

  16. Absorbed doses received by infants subjected to panoramic dental and cephalic radiographs; Dosis absorbida recibida por infantes sometidos a radiografias dentales panoramicas y cefalicas

    Energy Technology Data Exchange (ETDEWEB)

    Carrizales, L; Carreno, S [Instituto Venezolano de Investigaciones Cientificas. Laboratorio Secundario de Calibracion Dosimetrica. Carretera Panamericana Km. 11. Apartado Postal 21827, Caracas (Venezuela)

    1999-12-31

    The IAEA Report No. 115 recommends that each country or region can establish levels of absorbed doses for each radiographic technique employed in diagnostic. assuming the extended and expensive of this purpose, we have been to begin in a first step with the dentistry area, in order to estimate the dose levels received at crystalline and thyroid level in infants that go to an important public institution in our country to realize panoramic and cephalic radiographs. This work will serve to justify and impel a quality assurance program in Venezuela on the dentistry area which includes aspects such as training for the medical lap referring the justification of the radiological practice, optimization of X-ray units to produce an adequate image quality that delivers to patient an absorbed dose as much lower as reasonably it can be reached without diagnostic detriment. (Author)

  17. Thyroid dose of I-131 absorbed by the internal organs of a pregnant woman; Dosis tiroidea de I-131 absorbida por los organos internos de una embarazada

    Energy Technology Data Exchange (ETDEWEB)

    Arcos P, A; Manzanares A, E; Vega C, H R; Leon, C.L. de . [Cuerpo Academico de Radiobiologia de la Universidad Autonoma de Zacatecas (Mexico)

    2007-07-01

    The use of nuclear techniques, for diagnosis or treatment, generates stress in the patient and its relatives. During the pregnancy some sufferings related with the thyroid gland can be presented. If the patient is pregnant, OEP or NOEP, the stress comes from the fear to that the product can it turns affected. The dose is calculated that the Iodine 131, captured by the thyroid of a woman with three months of pregnancy, it deposits in the brain, stomach, heart, kidneys, liver, lungs, ovaries, pancreas, thymus, spleen and in the uterus. The thymus is the organ that receives the biggest dose. (Author)

  18. MYDOZE: Application Web for management and optimisation of doses to patients in tests radiodiagnostics; MYDOZE: Aplicacion Web para gestion y optimizacion de dosis a pacientes en pruebas radiodiagnosticas

    Energy Technology Data Exchange (ETDEWEB)

    Peinado Zamora, A. B.; Laguna Lobato, M. A.; Gil Agudo, A.; Zapata Jimenez, J. C.

    2013-07-01

    The service of Radiofisica y Proteccion Radiologica del Hospital general Universitario de Ciudad Real, carried out a study whose objective is to optimize the dose to patients undergoing diagnostic scans with ionizing radiation. To address this task, is required a software tool that facilitates on the one hand the acquisition of dosimetric data acquired digital equipment and the other interface of exploitation of this data for statistics and analysis of these. the computer tool to develop should allow storing parameters with information demographic and dose of the patient in medical scans thanks to called DICOM medical image standard. (Author)

  19. DOSIS: a computer program for the calculation of absorbed dose in photon and electron beams from ionization measurements in a phantom

    Energy Technology Data Exchange (ETDEWEB)

    Andreo, P [Kungliga Karolinska Mediko-Kirurgiska Inst., Stockholm (Sweden). Radiofysiska Institutionen; Zaragoza Univ. (Spain). Dept. de Radiologia)

    1983-06-15

    A computer program has been developed to facilitate the calculation of the absorbed dose in photon and electron beams from measurements with an ionization chamber in a phantom. The generalized Bragg-Gray theory, introduced in the latest recommendations of the Nordic Association of Clinical Physics (NACP), is used throughout the code, including more updated parameter values than those included in the NACP protocol. The calibration factor of the ionization chamber in units of absorbed dose in the air of the cavity can be derived for most of the chambers available today by using experimental data or fitted relations to Monte Carlo results.

  20. Analysis of the evolution of the collective dose in nuclear power plants in Spain; Analisis de la evolucion de la dosis colectiva en las centrales nucleares de Espana

    Energy Technology Data Exchange (ETDEWEB)

    Ponjuan Reyes, G.; Ruibia Rodiz, M. A. de la; Rosales Calvo, M.; Labarta Mancho, T.; Calavia Gimenez, I.

    2011-07-01

    This article presents an analysis of the evolution of occupational collective dose of the Spanish nuclear power plants during the period 2000 - 2008 within the international context, by the Nuclear Safety Council (CSN) in order to have information contrasted to assessing the extent of application of the ALARA criteria in the Spanish plants and identify areas of priority attention.

  1. Evaluation of doses received by pediatric and adult patients undergoing to CT exams; Evaluacion de la dosis recibida por pacientes adultos y pediatricos en examenes de tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Lavie, Maria F. Jimenez; Tejeda, Adalberto Machado, E-mail: felicia@cceem.sld.cu, E-mail: adalberto@cceem.sld.cu [Centro para el Control Estatal de Medicamentos, Equipos y Dispositivos Medicos (CECMED), La Habana (Cuba); Otano, Anisia; Zuniga, Dora Maya [Hospital Pediatrico Centro Habana (Cuba); Perdomo, Jorge Hing; Rodriguez, Gustavo Guadarrama [Hospital Docente Clinico Quirurgico Freyre Andrade, La Habana (Cuba)

    2013-07-01

    This paper aims to evaluated the dose to adult and pediatric patients due to the execution of tests CT scan of head, chest and abdomen, as well as establish a comparative analysis between these results and protocols involving employees to begin a process optimization in the practice.

  2. Analysis of the health of a group exposed to low doses of ionizing radiation; Analisis de salud en un grupo expuesto a dosis bajas de radiaciones ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Diaz Ledesma, F [Servicio Medico de Tecnatom, SA Madrid (Spain); Crespo, H [Hospital Gregorio Maranon de Madrid, Madrid (Spain)

    1997-11-01

    In order to evaluate the effects of exposure to low radiation doses, the health status of professional staff exposed to ionizing radiation is investigated. Based on archived material of medical and radiation exposure records taken over a time span of 13 years, a variety of medical parameters are explored. Findings of surveys made are given. (author). 1 fig.

  3. Independent dose calculation of the Tps Iplan in radiotherapy conformed with MLC; Calculo independiente de dosis del TPS Iplan en radioterapia conformada con MLC

    Energy Technology Data Exchange (ETDEWEB)

    Adrada, A.; Tello, Z.; Medina, L.; Garrigo, E.; Venencia, D., E-mail: jorge.alberto.adrada@gmail.com [Instituto Privado de Radioterapia, Obispo Oro 423, X5000BFI Cordoba (Argentina)

    2014-08-15

    The systems utilization of independent dose calculation in three dimensional-Conformal Radiation Therapy (3D-Crt) treatments allows a direct verification of the treatments times. The utilization of these systems allows diminishing the probability of errors occurrence generated by the treatment planning system (Tps), allowing a detailed analysis of the dose to delivering and review of the normalization point (Np) or prescription. The independent dose calculation is realized across the knowledge of dosimetric parameters of the treatment machine and particular characteristics of every individual field. The aim of this work is develops a calculation system of punctual doses for isocentric fields conformed with multi-leaf collimation systems (MLC), where the dose calculation is in conformity with the suggested ones by ICRU Report No. 42, 1987. Calculation software was realized in C ++ under a free platform of programming (Code::Blocks). The system uses files in format Rtp, exported from the Tps to systems of record and verification (Lantis). This file contains detailed information of the dose, Um, position of the MLC sheets and collimators for every field of treatment. The size of equivalent field is obtained from the positions of every sheet; the effective depth of calculation can be introduced from the dosimetric report of the Tps or automatically from the DFS of the field. The 3D coordinates of the isocenter and the Np for the treatment plan must be introduced manually. From this information the system looks the dosimetric parameters and calculates the Um. The calculations were realized in two accelerators a NOVALIS Tx (Varian) with 120 sheets of high definition (hd-MLC) and a PRIMUS Optifocus (Siemens) with 82 sheets. 705 patients were analyzed for a total of 1082, in plans made for both equipment s, the average uncertainty with regard to the calculation of the Tps is-0.43% ± 2.42% in a range between [-7.90 %, 7.50 %]. The major uncertainty was in Np near of the

  4. Pilot study of the dose in crystalline lens in the interventional radiology practice; Estudio piloto de la dosis en cristalino en la practica de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Castro, A.; Martinez, A.; Fernandez, A.; Molina, D. [Centro de Proteccion e Higiene de las Radiaciones, Carretera de la Cantera, Victoria II, Km. 21.5 Guanabacoa, La Habana (Cuba); Sanchez, L.; Diaz, A., E-mail: ailza@cphr.edu.cu [Hospital Clinico Quirurgico Hermanos Ameijeiras, San Lazaro 701, Centro Habana, La Habana (Cuba)

    2014-08-15

    The interventional radiology involves considerable exposure levels for the occupationally exposed personnel (OEP). The doses can encompass a wide range of values in dependence of the function that develops the personnel and the complexity of each procedure. In organs like the crystalline lens and skin values can be reached that imply the appearance of deterministic effects if is not fulfilled the appropriate measures of radiological protection. This has been demonstrated through multiple studies, among those that the retrospective study of damages in the crystalline lens and dose has been one of those most commented, known as RELID. The objective of that study was to examine the opacity prevalence in the crystalline lens in workers linked to the interventional cardiology and to correlate it with the occupational exposition. The obtained results contributed to that the ICRP recommend a new limit value of equivalent dose for crystalline lens of 20 mSv in one year. With the objective of analyzing the operational implications, in the radiological surveillance programs that they could originate with the new recommendations was developed a pilot study to evaluate the dose in crystalline lens in the OEP linked to the interventional radiology in a Cuban hospital. For this, an anthropomorphic mannequin RANDO-ALDERSON was used on which thermoluminescent dosimeters were placed below and above of the leaded apron and in different positions at level of the crystalline lens: above, below and to the sides of the leaded lenses that the personnel uses routinely. The mannequin was located on the same positions that occupy the main specialist that execute the procedure, as well as of the nurse to assist him. The measurements were made simulating the more representative procedures about complexity, duration time and exposure rate. The used dosimeters were RADOS model for whole body composed of two thermoluminescent detectors Gr-200 (LiF: Mg, Cu, P) to evaluate personal equivalent dose

  5. Dosimetric behavior of thermoluminescent dosimeters at low doses in diagnostic radiology; Comportamiento dosimetrico de dosimetros termoluminiscentes a bajas dosis en radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Del Sol F, S.; Garcia S, R.; Guzman M, J.; Sanchez G, D.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Ramirez R, G. [Hospital Juarez de Mexico, Av. IPN 5160, Col. Magdalena de las Salinas, 07760 Mexico D. F. (Mexico); Gaona, E., E-mail: susi2489@hotmail.com [Universidad Autonoma Metropolitana, Unidad Xochimilco, Calz. del Hueso 1100, Col. Villa Quietud, 04960 Mexico D. F. (Mexico)

    2015-10-15

    Thermoluminescent (Tl) characteristics of TLD-100, LiF:Mg,Cu,P, and CaSO{sub 4}: Dy the under homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescent dosimetry is presented. The irradiations were performed utilizing an X-ray beam generated by a Radiology Mexican Company: MRH-II E GMX 325-AF SBV-1 model, with Rotating Anode X-Ray Tube installed in the Hospital Juarez Norte de Mexico in Mexico City. Different thermoluminescent characteristics of dosimetric material were studied, such as, batch homogeneity, Tl glow curve, Tl response as a function of X-ray dose, reproducibility and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and positioned in a generic Phantom was used. Dose verification and comparison with the measurements made with that obtained by TLD-100 were analyzed. Preliminary results indicate the dosimetric peak appears at 243, 236 and 277 ± 5 degrees C respectively, these peaks are in agreement with that reported in the literature. Tl glow curve as a function of X-ray dose showed a linearity in the range from 1.76 mGy up to 14.70 mGy for all materials. Fading for a period of one month at room temperature showed low fading LiF:Mg,Cu,P, medium and high for TLD-100 and CaSO{sub 4}: Dy. The results suggest that the three materials are suitable for measurements at low doses in radiodiagnostic, however, for its dosimetric characteristics are most effective for individual applications: personal dosimetry and monitors limb (LiF:Mg,Cu,P), clinical dosimetry and environmental (TLD-100 and CaSO{sub 4}: Dy). (Author)

  6. Kinetics of the early adaptive response and adaptation threshold dose; Cinetica de la respuesta adaptativa temprana y dosis umbral de adaptacion

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M.T.; Morales R, P. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The expression kinetics of the adaptive response (RA) in mouse leukocytes in vivo and the minimum dose of gamma radiation that induces it was determined. The mice were exposed 0.005 or 0.02 Gy of {sup 137} Cs like adaptation and 1h later to the challenge dose (1.0 Gy), another group was only exposed at 1.0 Gy and the damage is evaluated in the DNA with the rehearsal it makes. The treatment with 0. 005 Gy didn't induce RA and 0. 02 Gy causes a similar effect to the one obtained with 0.01 Gy. The RA was show from an interval of 0.5 h being obtained the maximum expression with 5.0 h. The threshold dose to induce the RA is 0.01 Gy and in 5.0 h the biggest quantity in molecules is presented presumably that are related with the protection of the DNA. (Author) =.

  7. Determination of the dose around an ovoid for treatments in intracavitary brachytherapy Hdr; Determinacion de la dosis alrededor de un ovoide para tratamientos en braquiterapia intracavitaria HDR

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Velasco V, R. A. E. [Hospital Central Militar, Periferico y Ejercito Nacional s/n, Lomas de Sotelo, 11200 Mexico D. F. (Mexico); Serrano F, A. K. [Hospital Juarez de Mexico, Av. Instituto Politecnico Nacional No. 5190, Col. Magdalena de las Salinas, 03220 Mexico D. F. (Mexico); Azorin N, J., E-mail: trivera@ipn.m [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2010-09-15

    On this work the results of the dosimetric measurements are presented around an ovoid of 2 cm diameter. The measurements were carried out using a water mannequin, an ovoid, a radiation gamma source of {sup 192}Ir and thermoluminescent dosemeters. The dosimetry was realized in the direction of the rectum and bladder. To know the effect of the shielding of the devices type Manchester in the dose, the thermoluminescent dosemeters were irradiated to a radiation gamma source of {sup 192}Ir contained in the Gamma med Plus equipment. The planning was realized normalizing the calculation to 2.5 cm from the applicator center on the transverse plane (2.5, 0, 0). The results show that the dose distribution for an ovoid without shielding is more uniform in the transversal plane to the source axis. The results were compared with the calculated results by means of the planning system BrachyVision. While the absorbed dose distribution around an ovoid with shielding is completely anisotropic. This anisotropic is due to the shielding. (Author)

  8. Dose distribution perturbation due to a Co-Cr-Mo prosthesis; Perturbacion introducida en la distribucion de dosis por una protesis de Co-Cr-Mo

    Energy Technology Data Exchange (ETDEWEB)

    Castro Novais, J.; Rodriguez Rodriguez, C.; Cabello Murillo, E.; Fernandez Leton, P.; Perez Moreno, J. M.; Lopez Fernandez, A.; Ferrando Sanchez, A.; Martinez Gomez, L. C.

    2009-07-01

    Knowledge of the attenuation and interface effects when irradiating metallic prosthesis is necessary for the radiotherapy treatment of patients with this kind of implants. This report studies the dose distribution of a 6 MV photon beam in the vicinity of a 1,5 cm diameter Co-Cr-Mo prosthesis. Measurements with Gafchromic EBT radiochromic films have been made. Two blocks of cut films have been placed next to the prosthesis, one in each side. Forty two films reaching a height of 1 cm have been piled up in each block. A spatial resolution equal to the thickness of one film (0,24 mm) is achieved. The results show 28% attenuation and the production of a 42% overdose at the entrance interface, 12% and 3% at 1 mm and 2 mm away from the prosthesis respectively. A 5 mm build-up region is originated in the exit interface, where the under dose is less than 10%. The knowledge of the transmission factor and the interface effects allows us to assess the dose calculated by the treatment planning system. (Author) 11 refs.

  9. Measurement of personal equivalent dose Hp(3) during procedures involving in positron emission tomography; Medida del equivalente de dosis personal en cristalino Hp(3) durante los procedimientos asociados a la tomografía por emisión de positrones

    Energy Technology Data Exchange (ETDEWEB)

    Guiu Souto, J.; Sánchez García, M.; Vázquez, R.; Pardo Montero, J.; Pombar Cameán, M.

    2017-11-01

    The aim of the present study consists to determinate the personal equivalent dose Hp(3) at eye lens during the procedures involved in positron emission tomography. We have monitored the nurse's staff which is responsible of handling and dispensing 18F. We characterize the relevant stages as the preparation, the transport and the administration of monodose syringes in terms of occupational dose. We observed that the preparation presents a major contribution to the occupational doses than the other stages. In addition, during those stage there is a correlation between the dose increments and handling activity. To establish the eye lens dose we use the following dosimetry set: a direct readout solid state dosimeter for general purposes calibrated at Hp(10) and a set of thermolumiscent dosimeters specific for 18F calibrated at Hp(3). Finally, for the dose intercomparison between above dosimeters we obtain a correction factor by Monte Carlo. The eye lens dose, with a value of 2.8 ± 0.4 mSv/yr, results more critical than the dose obtained in other locations, as extremities. [Spanish] El propósito del presente trabajo consiste en la determinación del equivalente de dosis personal Hp(3) en cristalino durante los procedimientos asociados a la tomografía por emisión de positrones. Se ha monitorizado al personal de enfermería que realiza las tareas de manipulación y dispensación del 18F. Se ha realizado un estudio caracterizando la dosis en las etapas más relevantes del procedimiento: la preparación manual de las jeringuillas, el transporte de las mismas y su posterior administración al paciente. Se observó que la preparación es la etapa que más contribuye a la dosis ocupacional, además durante dicha etapa se observa una clara correlación entre el incremento de dosis y la actividad manipulada. Para determinar la dosis en cristalino se ha utilizado el siguiente equipo dosimétrico: un detector de estado sólido de lectura directa de propósito general

  10. Parameter calculation tool for the application of radiological dose projection codes; Herramienta de calculo de parametros para la aplicacion de codigos de proyeccion de dosis radiologicas

    Energy Technology Data Exchange (ETDEWEB)

    Galindo G, I. F.; Vergara del C, J. A.; Galvan A, S. J. [Instituto Nacional de Electricidad y Energias Limpias, Reforma 113, Col. Palmira, 62490 Cuernavaca, Morelos (Mexico); Tijerina S, F., E-mail: francisco.tijerina@cfe.gob.mx [CFE, Central Nucleoelectrica Laguna Verde, Carretera Federal Cardel-Nautla Km 42.5, 91476 Municipio Alto Lucero, Veracruz (Mexico)

    2016-09-15

    The use of specialized codes to estimate the radiation dose projection to an emergency postulated event at a nuclear power plant requires that certain plant data be available according to the event being simulated. The calculation of the possible radiological release is the critical activity to carry out the emergency actions. However, not all of the plant data required are obtained directly from the plant but need to be calculated. In this paper we present a computational tool that calculates the plant data required to use the radiological dose estimation codes. The tool provides the required information when there is a gas emergency venting event in the primary containment atmosphere, whether well or dry well and also calculates the time in which the spent fuel pool would be discovered in the event of a leak of water on some of the walls or floor of the pool. The tool developed has mathematical models for the processes involved such as: compressible flow in pipes considering area change and for constant area, taking into account the effects of friction and for the case of the spent fuel pool hydraulic models to calculate the time in which a container is emptied. The models implemented in the tool are validated with data from the literature for simulated cases. The results with the tool are very similar to those of reference. This tool will also be very supportive so that in postulated emergency cases can use the radiological dose estimation codes to adequately and efficiently determine the actions to be taken in a way that affects as little as possible. (Author)

  11. Monte Carlo determination of dose in crystalline and thyroid during chest tomography examinations; Determinacion Monte Carlo de dosis en cristalino y tiroides durante examenes de tomografia de torax

    Energy Technology Data Exchange (ETDEWEB)

    Quispe H, B.; Pena V, J. D.; Waldo B, G.; Leon M, M.; Ceron R, P.; Vallejo H, A.; Sosa A, M. [Universidad de Guanajuato, Campus Leon, Division de Ciencias e Ingenierias, Loma del Bosque 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Vega C, H. R., E-mail: b.quispehuillcara@ugto.mx [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas, Zac. (Mexico)

    2017-10-15

    Computed tomography is a diagnostic imaging method that deposits higher doses than other radio diagnosis methods. The knowledge of the spectrum of X-rays is important, since is in direct function with the dose absorbed by the patient. In this work we estimated the spectrum of X-rays, produced during the interaction of monoenergetic electrons of 130 KeV with Tungsten white, in order to determine their energetic characteristics at 50 cm from the focal point. The study was done using Monte Carlo methods with the code MCNP5 where the X-ray tube of a Siemens SOMATOM Perspective tomograph of the General Regional Hospital of Leon, Mexico was modeled. In the calculations, 3 x 10{sup 8} stories were used and a relative uncertainty of less than 0.1% was obtained. Also, a neck manikin with thyroid, thorax and head that included the eye, the table and gantry with 70 cm opening of the tomography was modeled. The X-ray spectrum calculated with a cut thickness of 10 mm limited by Pb collimators was used as the source term. The radiological service routine scanning protocol was used for chest computed tomography; the step-by-step or instant trigger method was simulated by moving the manikin coordinates for each cut and 360 degree continuous rotation movement. 36 positions of the X-ray tube were used in steps of 10 degrees. The radiation dispersed in the thorax deposits a dose of 2.063 mGy in crystalline and 252 mGy in thyroid. (Author)

  12. Degradation of polylactic acid (Pla) at different doses of gamma radiation; Degradacion del acido polilactico (PLA) a diferentes dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Castillo R, Y.

    2015-07-01

    The excessive use of polymers such as polyethylene (PET), polystyrene (Ps) and recently the polylactic acid (Pla) that take more than 20 years to degrade, have caused great pollution in the environment. In this study the effects of gamma radiation in the Pla to different doses were studied, in order to reduce the degradation time of this polymer. The changes in physico-chemical structure of Pla during radiation were studied by thermo-gravimetric/Mass analysis; differential scanning calorimetry; scanning electron microscopy; X-ray dispersive analysis; infrared spectroscopy; X-ray diffraction and mechanical tests of hardness, elasticity and deformation. With scanning electron microscopy, the morphology of the Pla surface unirradiated was observed, in which an apparently smooth surface was observed, after changes that had the Pla when irradiated also was observed, where the effects of radiation were observed in form of scratch, agglomeration and small fractures. By X-ray dispersive analysis was determined and verified the elemental chemical composition of the Pla; as expected the tests showed only carbon, oxygen and hydrogen. With thermo-gravimetric/Mass analysis the decomposition temperatures of Pla were determined, identifying that the degradation compounds are CO, CO{sub 2} and CH{sub 4}. With infrared spectrometry the major peaks of Pla were observed before and after being irradiated with increasing of radiation dose the intensity of the bands decreased. Also by X-ray diffraction was observed that the polymer is an amorphous material. The mechanical tests indicate that the values of each of the tests decrease significantly with increasing the radiation dose. (Author)

  13. Comparison between calculation methods of dose rates in gynecologic brachytherapy; Comparacion entre metodos de calculo de tasa de dosis en braquiterapia ginecologica8

    Energy Technology Data Exchange (ETDEWEB)

    Vianello, E.A.; Biaggio, M.F.; Dr, M.F.; Almeida, C.E. de [Laboratorio de Ciencias Radiologicas- (L.C.R.)-D.B.B.- UERJ- R. Sao Francisco Xavier, 524- Pav. HLC- sala 136- CEP 20550-013 Rio de Janeiro (Brazil)

    1998-12-31

    In treatments with radiations for gynecologic tumors is necessary to evaluate the quality of the results obtained by different calculation methods for the dose rates on the points of clinical interest (A, rectal, vesicle). The present work compares the results obtained by two methods. The Manual Calibration Method (MCM) tri dimensional (Vianello E., et.al. 1998), using orthogonal radiographs for each patient in treatment, and the Theraplan/T P-11 planning system (Thratonics International Limited 1990) this last one verified experimentally (Vianello et.al. 1996). The results show that MCM can be used in the physical-clinical practice with a percentile difference comparable at the computerized programs. (Author)

  14. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  15. Determination of optimal doses of radiation for the plant breeding of pseudo cereals; Determinacion de dosis optimas de radiacion para el mejoramiento de seudocereales

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gomez P, L [Universidad Nacional Agraria La Molina, Lima (Peru)

    2005-07-01

    With the purpose of promoting the use of the radiations for the plant breeding of pseudo cereals, it was determined a simple and economic method that allows the quick selection of radiation dose that induce in the vegetable organisms the changes wanted. For it it was work with quinua seeds (Chenopodium quinoa Willd.) an Andean pseudo cereal that, due to their nutritious and physiologic characteristics it is considered by the FAO like one of the foods of the future and for the NASA like an organism that is good to remove the carbon dioxide from the atmosphere and at the same time, to generate food, oxygen and water for the crew during the space missions of long duration and that it has already improved by means of the radiation application. The proposed method consists on the evaluation, of the embryonic structures (radicule, hypocotyl and cotyledons) in the irradiated seeds as well as of the development of root, primary shaft and true leaves in the plants. The changes in the growth, form, number and color of the structures as well as the time of appearance of each one, allow to predict the morphological changes and inclusive some physiologic ones that will have the mature organisms, so that in only three weeks it is possible to select the doses more appropriate. (Author)

  16. Hidratación oral continua o a dosis fraccionadas en niños deshidratados por diarrea aguda Oral rehydration in continuous administration or in fractionated doses in dehydrated children with acute diarrhea

    Directory of Open Access Journals (Sweden)

    Felipe Mota-Hernández

    2002-01-01

    Full Text Available Objetivo. Evaluar la seguridad y efectividad de dos técnicas de hidratación oral. Material y métodos. Ensayo clínico aleatorio, hecho en el Servicio de Hidratación Oral del Hospital Infantil de México, Federico Gómez, entre septiembre de 1998 y junio de 1999. Cuarenta pacientes deshidratados por diarrea aguda, menores de cinco años, recibieron suero oral ad libitum (grupo AL y otros cuarenta lo recibieron en dosis fraccionada (grupo DF. Las características clínicas fueron similares en ambos grupos. Los resultados se presentan como promedio y desviación estándar o mediana, según la distribución de frecuencias simples y relativas. Resultados. El promedio de gasto fecal en el grupo AL fue 11.0±7.5 g/kg/h y en el grupo DF 7.1±7.4 (p=0.03. La ingesta de suero, el tiempo de hidratación y la diuresis promedio, fueron similares entre ambos grupos (p>0.05. Seis pacientes del grupo AL y cinco del DF tuvieron gasto fecal alto (>10 g/kg/hora, mejorando con la administración de atole de arroz. Un paciente del grupo AL y dos pacientes del DF tuvieron vómitos persistentes, mejorando con gastroclisis. Ningún paciente requirió rehidratación intravenosa. Conclusiones. Estos resultados sugieren que la administración de suero oral ad libitum, bajo supervisión, es tan segura y efectiva como la técnica de dosis fraccionada para el tratamiento de niños deshidratados por diarrea aguda.Objective. To evaluate the safety and effectiveness of two oral rehydration techniques. Material and Methods. A randomized clinical trial was conducted at the oral rehydration unit of Hospital Infantil de Mexico "Federico Gomez", between September 1998 and June 1999. Forty patients five-year old and younger children, dehydrated due to acute diarrhea, were given oral rehydration solution (ORS ad libitum (AL group; another forty patients received ORS in fractionated doses (FD group. Clinical characteristics were similar in both groups. Results are presented as

  17. Dose by {sup 222} Rn in houses of the Chihuahua city; Dosis por {sup 222} Rn en casas-habitacion de la ciudad de Chihuahua

    Energy Technology Data Exchange (ETDEWEB)

    Colmenero S, L.H.; Talamantes F, C. [ITCH II, Ave. de las Industrias 11101, Chihuahua (Mexico); Villalba, M.L. [UACH, Facultad de Ingenieria, Chihuahua (Mexico); Dobson, P.F. [Laboratorio Nacional Lawrence Berkeley, California (United States); Ortalejo M, B. [UACH, Facultad de Enfermeria y Nutriologia, Chihuahua (Mexico)]. e-mail: luis.colmenero@cimav.edu.mx

    2007-07-01

    Full text: The dose equivalent that the population of the Chihuahua city receives due to the radon in air that joined to values of uranium, thorium and potassium due to the floor and radon in water was determined, they give values very above the international and national norms. The state of Chihuahua contains near 56 locations distributed by the whole state. The city of Chihuahua, capital of the state, is surrounded of rocks with great content of uranium, for what their floor also contains to the {sup 226} Ra that generates to the {sup 222} Rn. The construction of the housings of the city of Chihuahua is mainly of brick, block and adobe; the material to elaborate them is take from the rocks and floor of the surroundings, this makes that the radon is presented in a great quantity of houses of this city. As the floor and water they also contain those natural radionuclides, the total dose equivalent that the inhabitants receive is bigger to other cities of the country. Diverse international organizations dedicated to the radioactivity, indicate that the level of the {sup 222} Rn should not surpass the 148 Bq/m{sup 3}, since this gas produces lung cancer. The state of Chihuahua has an index of deaths on the average by lung cancer of double the national average, the capital of the state also has a high index. The radon concentration in a house depends on the construction material with which was made, as well as of the existent climatic conditions. During the day, this concentration depends mainly on the interior temperature, so during the night and dawn increases the radon concentration. The radon is the biggest source of radioactive dose received by the human being and it can generate a problem of public health if the concentration is high during enough time, for what the city of Chihuahua has the geologic and climatic characteristics to have it. This study was carried out in 50 house-room of the city of Chihuahua. Built houses with brick, block and adobe were

  18. Biological assay of chromatin dispersal simplified for determining absorbed dose of ionizing radiation; Ensayo biologico simplificado de dispersion de cromatina para la determinacion de dosis de radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Galaz, S.; Perez, G.; Stockert, J. C.; Blazquez-Castro, A.

    2011-07-01

    Currently, the production of nuclear halos chromatin dispersion methods is a good procedure for nuclear analysis by in situ hybridization (Wiegant et al., 1992, Gerdes et al. 1994), to detect apoptosis, DNA fragmentation and cell death rates in cell cultures (Fernandez et al., 2005, Enciso et al. 2006). It is customary to display the nuclear halos by fluorescence microscopy using propidium iodide, ethidium bromide or DAPI (Gerdes et al., 1994, Sestili et al. 2006). Using this technique based on a modified protocol of fast halo assay [FHA],(Sestili et al. 2006), has developed a simplified method to quantify the cytogenetic damage induced by ionizing radiation (dispersion test chromatin in agarose thin smear), which allows visualization of halos after staining for light microscopy or fluorescence and correlating the ratio: total area occuped by the halo nucleus / nucleus (halo-core index [IHN] ) with radiation dose.

  19. Evaluation of the dose to patients during extracorporated lithotripsy treatment (ESWL); Evaluacion de dosis a paciente durante el tratamiento con litotricia extracorporea (ESWL)

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, M F; Roman, J R [Servicio de Fisica Medica, Hospital Universitario de Valme, Sevilla (Spain)

    1997-11-01

    Litiasis urinaria is appearing more frequently with approximately 12% of the population with a stone in the urinary system at any moment of their life. The stone produces severe colics causing pain in the transit through the ureter. This is probably one of the worst pains and experiences in human beings. The treatment by extracorporated lithotripsy consists of powdering or smashing into pieces the stones in the kidney and ureter. This has been done with the help of shock waves generated from a canon and which are focused on the stone. The machine used is aimed and the procedure is monitored by way of X rays. The high number of patients treated per year and the doses applied to the patients during the diagnosis, treatment and follow-up led to this study. 7 refs, 5 figs, 4 tabs.

  20. Characterization of an absorbed dose standard in water through ionometric methods; Caracterizacion de un patron de dosis absorbida en agua mediante metodos ionometricos

    Energy Technology Data Exchange (ETDEWEB)

    Vargas V, M.X

    2003-07-01

    In this work the unit of absorbed dose at the Secondary Standard Dosimetry Laboratory (SSDL) of Mexico, is characterized by means of the development of a primary standard of absorbed dose to water, D{sub agua}. The main purpose is to diminish the uncertainty in the service of dosimetric calibration of ionization chambers (employed in radiotherapy of extemal beams) that offers this laboratory. This thesis is composed of seven chapters: In Chapter 1 the position and justification of the problem is described, as well as the general and specific objectives. In Chapter 2, a presentation of the main quantities and units used in dosimetry is made, in accordance with the recommendations of the International Commission on Radiation Units and Measurements (ICRU) that establish the necessity to have a coherent system with the international system of units and dosimetric quantities. The concepts of equilibrium and transient equilibrium of charged particles (TCPE) are also presented, which are used later in the quantitative determination of D{sub agua}. Finally, since the proposed standard of D{sub agua} is of ionometric type, an explanation of the Bragg-Gray and Spencer-Attix cavity theories is made. These theories are the foundation of this type of standards. On the other hand, to guarantee the complete validity of the conditions demanded by these theories it is necessary to introduce correction factors. These factors are determined in Chapters 5 and 6. Since for the calculation of the correction factors Monte Carlo (MC) method is used in an important way, in Chapter 3 the fundamental concepts of this method are presented; in particular the principles of the code MCNP4C [Briesmeister 2000] are detailed, making emphasis on the basis of electron transport and variance reduction techniques used in this thesis. Because a phenomenological approach is carried out in the development of the standard of D{sub agua}, in Chapter 4 the characteristics of the Picker C/9 unit, the

  1. Critical Survey of the Analysis of Microscopic Distribution of some Bone-Seeking Radionuclides and Assessment of Absorbed Dose; Analyse de la Distribution Microscopique de Radionucleides Osteophiles et Determination de la Dose Absorbee; Kriticheskij obzor dannykh analiza mikroskopicheskogo raspredeleniya otkladyvayushchikhsya v kostyakh radioizotopov i opredelenie pogloshchennoj dozy; Estudio Critico de la Distribucion Microscopica de Algunos Radionuclidos Osteofilos y Evaluacion de la Dosis Absorbida

    Energy Technology Data Exchange (ETDEWEB)

    Jee, W. S.S.

    1964-10-15

    des rayonnements emis par le plutonium depose en surface sur les diverses parties de la zone distale du femur sont les suivants: trabecule metaphysaire, 3; periode interne, 2,6; trabecule epiphysaire, 1,5; canaux de Havers, 1,2; perioste externe, 1. Le depot en surface maximum localise pour les trabecules des vertebres est 35 a 66 fois plus important que la moyenne calculee de debit de dose du a la retention dans le corps. Les auteurs discutent les modifications de la localisation initiale non uniforme du radium et du plutonium en fonction du temps dans leurs rapports avec la nature du remodelage cellulaire de l'os et avec la perte du radionucleide par echange a long terme. Enfin, dans un exemple avec des mesures de la dose de rayonnements locale du plutonium et du radium, faites compte tenu du volume des cellules irradiees, la retention du corps et l'incidence des tumeurs sont mises en correlation et utilisees pour obtenir une toxicite relative du plutonium par rapport au radium et demontrer la valeur d'une certaine connaissance de la distribution microscopique des doses de rayonnements. (author) [Spanish] Los estudios detallados sobre la distribucion microscopica de la dosis proporcionan informacion sobre la distribucion no uniforme de las radiaciones, a diferencia de la distribucion supuesta uniforme, que se deduce de los datos relativos a la retencion en todo el organismo. En ausencia de cierto conocimiento de la distribucion microscopica de la dosis, tanto en el espacio como en el tiempo, se corre el riesgo, al tratar de acopiar datos comparativos sobre la toxicidad, de llegar a deducciones erroneas y pasar por alto conclusiones importantes. A causa de la complejidad del problema, los datos publicados sobre la medicion de la distribucion microscopica de la dosis de irradiacion son muy escasos. Las tecnicas actuales recurren a la autorradiografia y son muy laboriosas. Exigen el recuento de trazas y trabajos de micro- densitometria. La determinacion de la

  2. The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cerenkov discrimination methods

    International Nuclear Information System (INIS)

    Frelin, A-M.; Fontbonne, J-M.; Ban, G.; Colin, J.; Labalme, M.; Batalla, A.; Vela, A.; Boher, P.; Braud, M.; Leroux, T.

    2008-01-01

    New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the Cerenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center Francois Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the

  3. The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: characterization of two Cerenkov discrimination methods.

    Science.gov (United States)

    Frelin, A M; Fontbonne, J M; Ban, G; Colin, J; Labalme, M; Batalla, A; Vela, A; Boher, P; Braud, M; Leroux, T

    2008-05-01

    New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the Cerenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center François Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the

  4. Effects of Variable Dose-Rates on Radiation Damage in the Rust-Red Flour Beetle, Tribolium Castaneum Herbst; Effets du debit de dose sur les dommages radioinduits chez le tenebrion roux (Tribolium Castaneum Herbst); Vliyanie razlichnykh moshchnostej doz na radiatsionnoe povrezhdenie krasnogo muchnogo zhuka, Tribolium Castaneum (Herbst); Radio lesiones que sufre el Tribolium Castaneum Herbst cuando se le somete a dosis de radiaciones de diversas intensidades

    Energy Technology Data Exchange (ETDEWEB)

    Nair, K. K.; Subramanyam, G. [Biology Division, Atomic Energy Establishment, Trombay, Bombay (India)

    1963-09-15

    In order to find out whether a change in dose-rate would significantly alter a radiation response, eggs as well as the adults of Tribolium castaneum were tested for viability and fertility respectively after exposure to gamma radiation at different dose-rates. The doses employed were 2000 and 5000 rad and the dose-rates ranged from 126 rad/h to 140 000 rad/h. It was observed that with an increase in dose-rate there was a decline in the fertility of the adults. Similarly the viability of the eggs was considerably reduced as the dose-rate increased, but at very high dose-rates there was a significant increase in viability. The significance of these findings is discussed. (author) [French] En vue de determiner si une variation du debit de dose modifie de maniere significative la reponse aux rayonnements, on a fait des essais sur des oeufs et des adultes de Tribolium castaneum, dont on a etudie respectivement la viabilite et la fecondite apres exposition a des doses de rayons gamma d'intensites differentes. On a administre des doses de 2000 et 5000 rad, le debit de dose variant de 126 a 140 000 rad/h. On a constate que la fecondite des adultes diminuait a mesure que le debit de dose augmentait. De meme, la viabilite des oeufs etait considerablement reduite a mesure que le debit de dose augmentait, mais pour des debits de dose tres eleves la viabilite augmentait sensiblement. Les auteurs analysent les donnees obtenues. (author) [Spanish] Para averiguar si un cambio en la intensidad de la dosis produce alteraciones fundamentales en la radiosensibilidad, se comprobo la viabilidad de los huevecillos y la fertilidad de los adultos de Tribolium castaneum despues de exponerlos a dosis de radiaciones gamma de intensidad diferente. Las dosis empleadas fueron 2000 y 5000 rad, y las intensidades oscilaron entre 126 rad/h y 140 000 rad/h. Al aumentar la intensidad de la dosis se produce una disminucion de la fertilidad de los adultos. De modo similar, la viabilidad de los

  5. Efecto de la administración de diferentes dosis de gonadotrofina coriónica equina sobre la respuesta ovárica y el desarrollo in vitro de embriones de ratón Effect of different doses of equine chorionic gonadotropin on ovary response and in vitro mouse embryo development

    OpenAIRE

    M. T. Teruel; R. C. Catalano; S. S. Callejas; J. A. Cabodevila; S. Gómez

    2006-01-01

    El objetivo del trabajo fue evaluar el efecto de diferentes dosis de gonadotrofina coriónica equina (eCG) (5, 7,5 o 10 UI) sobre parámetros ováricos y desarrollo in vitro de embriones de hembras ratón Balb C. El peso y diámetro ovárico fueron superiores en animales tratados con 7,5 y 10 UI de eCG que en animales controles (P

  6. Statistical Review of surface dose in the period 1995-2010, measured by different types of TLD dosimeters; Revision estadistica de las dosis superficiales, en el periodo 1995-2010, medidas mediante distintos tipos de dosimetros TLD

    Energy Technology Data Exchange (ETDEWEB)

    Pastor Antolin, S.; Munoz Blasco, J.; Llansana Arnalot, J.; Gultresa Colomer, J.

    2011-07-01

    We analyzed the evolution of the number of special controls over the period 1985 to 2010 and the evolution of the doses in the period 1995 to 2010. Comparing the standard dose extremities respect to whole body in cases where users use both types of control in the same installation.

  7. Individual dose control of workers

    International Nuclear Information System (INIS)

    Keverling Buisman, A.S.

    1990-01-01

    This publication has the character of a set of recommendations towards in practice working radiation protection specialists who are involved within their company or institute with the organization and performance of measurements in order to control the individual radiation burden caused by external exposition and internal contamination in applying radioactive materials and radiation apparatus. This publication gives information about the practical performance of personnel dosimetry at external exposure with a personnel dosimeter, which is carried on the body. The individual control of internal contamination is a much more complicated task. This publication assumes, with regard to this part, that people who are involved with it have been schooled as a radiation specialist level-3. For this part this publication contains numerical information needed for assessing of the individual effective follow-dose equivalence in occurring cases. A list with data of much used radionuclides is included. Also dosimetric data are presented which may be useful in case of contamination of skin and wounds. (author). 14 refs.; 2 figs.; 17 tabs

  8. Cambios en la presión arterial en un grupo de voluntarios normotensos después del consumo de diferentes dosis de café filtrado Changes in blood pressure in a group of normotense volunteers after consumption or different doses of filtered coffee

    Directory of Open Access Journals (Sweden)

    Gloria M Agudelo

    2008-12-01

    Full Text Available No es clara la asociación entre el consumo de café y los cambios en los niveles de presión arterial; si bien algunos estudios muestran una correlación positiva, otros no logran confirmarla. El objetivo de este estudio fue determinar el cambio en los niveles de presión arterial en un grupo de voluntarios normotensos sometidos al consumo de diferentes dosis de café filtrado. Se trata de un estudio prospectivo, clínico controlado, en el cual se conformaron cuatro grupos y se sometieron por un período de seis semanas al consumo de diferentes cantidades de café filtrado: el grupo uno no consumió café, el grupo dos consumió 200 mL, el tres 400 mL y el cuatro 600 mL. Antes y al final de la intervención, en cada sujeto se midieron los niveles de presión arterial; en el grupo control se midió la concentración de cafeína antes, durante y al final de la intervención. Los resultados mostraron grupos comparables por género, edad e índice de masa corporal, sin diferencias significativas en las condiciones basales. Después de la intervención, la presión arterial sistólica y diastólica no mostró diferencia intragrupos, excepto en el grupo cuatro en el cual disminuyó significativamente (p=0,006 la presión arterial diastólica. Entre grupos los cambios en los niveles de presión sistólica y diastólica no fueron significativos (p=0,510 y 0,430 respectivamente. En conclusión, el consumo de diferentes dosis de café filtrado no ocasionó en sujetos normotensos cambios significativos en los niveles de presión arterial; el grupo que se abstuvo de tomar café no mostró disminución significativa de la presión arterial.The association between coffee consumption and changes in blood pressure values is not clear yet. Although some studies show a positive correlation, others fail to confirm it. The aim of this study was to determine changes in blood pressure values in a group of normotense volunteers submitted to consumption of different

  9. Synthesis of Graft Copolymers by Small Doses of Irradiation; Synthese des copolymeres greffes au moyen de petites doses de rayonnements; Sintez privitykh sopolimerov s pomoshch'yu malykh doz oblucheniya; Sintesis de copolimeros de injerto mediante pequenas dosis de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Dobo, J; Somogyi, M; Kiss, L

    1960-07-15

    In addition to grafting, there is often an undesirable alteration in the properties of the original polymer when polymer monomer mixtures are irradiated. As a result of irradiation, grafting occurs not only on the original polymeric backbone, but also on the already grafted side-chains. The result is an acceleration of grafting. The effect is especially pronounced in the case of preformed polymers, if irradiation is carried out intermittently. The grafting of styrene can be accelerated by the addition of some solvents which suppress the protective effect of the styrene on the polymer. Grafting can be accelerated by other additives. The swelling properties of the irradiated films were investigated. (author) [French] Lorsque des melanges de polymeres et de monomeres sont soumis a des rayonnements, il se produit souvent, en meme temps que la greffe, une alteration facheuse des proprietes du polymere original. L'irradiation provoque une reaction de greffage, non seulement sur le polymere original, mais aussi sur les chaines laterales deja greffees. Il en resulte une acceleration du processus de greffage. L'effet est particulierement marque dans le cas des polymeres preformes, lorsque l'irradiation est effectuee par intermittence. On peut accelerer le processus de greffage du styrolene en ajoutant certains solvants qui suppriment l'action protectrice du styrolene sur le polymere. On peut aussi accelerer le processus a l'aide d'autres additifs. Les auteurs ont etudie les proprietes de gonflement des pellicules irradiees. (author) [Spanish] Simultaneamente con el injerto, bajo la accion de las radiaciones se produce frecuentemente una alteracion de las propiedades del polimero original, efecto que convendria evitar. Por lo tanto, quiza ofrezcan interes los elevados grados de injerto obtenidos en nuestros laboratorios con pequenas dosis de radiacion. La irradiacion no solo provoca una reaccion de injerto en la estructura polimerica original, sino tambien en las cadenas

  10. Metabolic dose-effect relationships of different Pt compounds on growing, pregnant, and lactating rats; Metabolische Dosis-Wirkungsbeziehungen verschiedener Pt-Verbindungen bei wachsenden, graviden und laktierenden Ratten (VPT 04)

    Energy Technology Data Exchange (ETDEWEB)

    Eder, K; Kirchgessner, M [Technische Univ. Muenchen, Freising (Germany). Lehrstuhl fuer Tierernaehrung

    1998-12-31

    The fact that humans can take up platinum via the food chain calls for an investigation of the effects of platinum ingestion on the organism. For this purpose a study was carried out on the dose-effect relationships of various platinum compounds using the rat as a model. To take due account of different physiological stages the study included growing, pregnant, and lactating rats. According to present knowledge platinum is primarily emitted in its elemental form by the catalytic converter, i.e. with the formal oxidation number zero, and to a lesser degree in ionic form. Beside elemental platinum the study therefore also involved exposure to PtCl{sub 2} and PtCl{sub 4}. Furthermore, to do justice to the fact that humans and animals take up platinum not only from its primary source but also from plants in the food chain, platinum was also administered as a Pt-II-phytochelatin complex previously isolated from Pt-contaminated material. Study criteria were chosen with a view to obtaining a general indication of potential toxic effects and included parameters such as the live weight curve, haematological status, and platinum accumulation in the body or in specific organs. Of particular interest in pregnant and lactating rats were platinum levels in foetuses and milk. [Deutsch] Ueber die Nahrungskette ist eine alimentaere Aufnahme von Platin durch den Menschen moeglich und erfordert, die Auswirkungen der ingestiven Platinzufuhr auf den Organismus zu untersuchen. Deshalb wurden am Modelltier Ratte Studien zur Dosis-Wirkungsbeziehung verschiedener Platinverbindungen durchgefuehrt. Um den verschiedenen physiologischen Stadien gerecht zu werden, wurden sowohl wachsende wie auch gravide und laktierende Ratten in die Studien einbezogen. Soweit bislang bekannt, wird Platin vorwiegend in der formalen Oxidationsstufe Null als elementares Platin, zu einem geringeren Anteil aber auch in ionischer Form aus der Katalysatoreinheit ausgetragen. Deshalb wurden in den vorliegenden

  11. Metabolic dose-effect relationships of different Pt compounds on growing, pregnant, and lactating rats; Metabolische Dosis-Wirkungsbeziehungen verschiedener Pt-Verbindungen bei wachsenden, graviden und laktierenden Ratten (VPT 04)

    Energy Technology Data Exchange (ETDEWEB)

    Eder, K.; Kirchgessner, M. [Technische Univ. Muenchen, Freising (Germany). Lehrstuhl fuer Tierernaehrung

    1997-12-31

    The fact that humans can take up platinum via the food chain calls for an investigation of the effects of platinum ingestion on the organism. For this purpose a study was carried out on the dose-effect relationships of various platinum compounds using the rat as a model. To take due account of different physiological stages the study included growing, pregnant, and lactating rats. According to present knowledge platinum is primarily emitted in its elemental form by the catalytic converter, i.e. with the formal oxidation number zero, and to a lesser degree in ionic form. Beside elemental platinum the study therefore also involved exposure to PtCl{sub 2} and PtCl{sub 4}. Furthermore, to do justice to the fact that humans and animals take up platinum not only from its primary source but also from plants in the food chain, platinum was also administered as a Pt-II-phytochelatin complex previously isolated from Pt-contaminated material. Study criteria were chosen with a view to obtaining a general indication of potential toxic effects and included parameters such as the live weight curve, haematological status, and platinum accumulation in the body or in specific organs. Of particular interest in pregnant and lactating rats were platinum levels in foetuses and milk. [Deutsch] Ueber die Nahrungskette ist eine alimentaere Aufnahme von Platin durch den Menschen moeglich und erfordert, die Auswirkungen der ingestiven Platinzufuhr auf den Organismus zu untersuchen. Deshalb wurden am Modelltier Ratte Studien zur Dosis-Wirkungsbeziehung verschiedener Platinverbindungen durchgefuehrt. Um den verschiedenen physiologischen Stadien gerecht zu werden, wurden sowohl wachsende wie auch gravide und laktierende Ratten in die Studien einbezogen. Soweit bislang bekannt, wird Platin vorwiegend in der formalen Oxidationsstufe Null als elementares Platin, zu einem geringeren Anteil aber auch in ionischer Form aus der Katalysatoreinheit ausgetragen. Deshalb wurden in den vorliegenden

  12. Measuring the absorbed dose in critical organs during low rate dose brachytherapy with {sup 137} Cs using thermoluminescent dosemeters; Medicion de la dosis absorbida en organos criticos durante braquiterapia de baja tasa de dosis con {sup 137} Cs usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Torres, A. [UAEM, Fac. de Medicina, 50180 Toluca, Estado de Mexico (Mexico); Gonzalez, P.R. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Furetta, C.; Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Andres, U.; Mendez, G. [Centro Estatal de Cancerologia de Tabasco, A. Gregorio Mendez No. 2838, Col. Atasta, 86100 Villahermosa, Tabasco (Mexico)

    2003-07-01

    Intracavitary Brachytherapy is one of the most used methods for the treatment of the cervical-uterine cancer. This treatment consists in the insertion of low rate dose {sup 137}Cs sources into the patient. The most used system for the treatment dose planning is that of Manchester. This planning is based on sources, which are considered fixed during the treatment. However, the experience has shown that, during the treatment, the sources could be displaced from its initial position, changing the dose from that previously prescribed. For this reason, it is necessary to make measurements of the absorbed dose to the surrounding organs (mainly bladder and rectum). This paper presents the results of measuring the absorbed dose using home-made LiF: Mg, Cu, P + Ptfe thermoluminescent dosimeters (TLD). Measurements were carried out in-vivo during 20 minutes at the beginning and at the end of the treatments. Results showed that the absorbed dose to the critical organs vary significantly due to the movement of the patient during the treatment. (Author)

  13. Computed tomography: influence of varying tube current on patient dose and correctness of effective dose calculations; Computertomografie: Einfluss des variablen Roehrenstroms auf die Patientendosis und die Genauigkeit von Berechnungen der effektiven Dosis

    Energy Technology Data Exchange (ETDEWEB)

    Hietschold, V. [Inst. und Poliklinik fuer Radiologische Diagnostik, Universitaetsklinikum Carl-Gustav-Carus der TU Dresden (Germany); Koch, A.; Laniado, M.; Abolmaali, N.D. [OncoRay, Molecular Imaging, TU Dresden (Germany)

    2008-05-15

    Purpose: determination of the influence of tube currents varying during a CT scan on organ doses and on the effective dose as a function of patient constitution. Evaluation of the accuracy of effective dose calculations based on summarizing parameters (effective mAs, dose length product [DLP]) compared to calculations based on slice-specific tube currents. Materials and methods: investigation of the CT datasets of 806 patients acquired from the skull base to the proximal thigh with respect to the body mass index (BMI). The effective dose was calculated by means of slice-specific as well as region-specific conversion factors. Results: dose optimization by means of variable tube current resulted in a reduction of the gonad dose in patients with BMI {<=} 20.. 21 kg/m{sup 2} and of the effective dose in patients with BMI {<=} 26 kg/m{sup 2}. Effective dose values calculated with the DLP for 90% of the patients are within an interval of {+-} 20% of the values calculated using slice-specific tube currents. Conclusion: if tube current optimization during the CT scan was applied, for the scan region under investigation, at a BMI already below the German mean value, an increased effective dose was observed. Calculations of the effective dose on the basis of summarizing values such as DLP or effective mAs are of sufficient accuracy. (orig.)

  14. Dosis de polvo de roca y sus efectos sobre el rendimiento del tomate

    Directory of Open Access Journals (Sweden)

    C. R. Enciso Garay

    2016-01-01

    Full Text Available La agricultura sustentable juega un rol muy importante en la producción continua de alimentos, donde se busca reducir la dependencia de fertilizantes minerales y el incremento del uso de fuentes naturales de nutrientes, con bajos impactos en el medio ambiente. Se ha evaluado el efecto de diferentes dosis de polvo de roca de origen basáltico en las características productivas del tomate cultivar Carina, a través de un experimento en el municipio de Caazapá, Departamento de Caazapá, Paraguay, en el periodo de 11/2012 a 04/2013. Los tratamientos consistieron en testigo sin fertilización, testigo experimental con fertilización química (basado en el análisis de suelo y diferentes dosis de polvo de roca de 0,5; 0,75; 1,0; 1,25; 1,5 y 2,0 t ha-1. El diseño experimental fue de bloques completos al azar con tres repeticiones. Cada unidad experimental estuvo constituida de 24 plantas, de las cuales fueron evaluadas ocho. Las variables medidas fueron masa media de frutos, rendimiento comercial y número comercial de frutos por planta (> 50 g. La comparación de medias por la prueba de Tukey al 5% de probabilidad arrojó que la fertilización química resultó en mayor rendimiento, masa media de frutos y número de frutos por planta. A partir de la dosis de polvo de roca de 1,0 t ha-1, se encontró efecto significativo sobre el número de frutos por planta y desde 0,75 t ha-1 sobre la masa de frutos y rendimiento, obteniéndose, los mejores resultados con las dosis más elevadas. El análisis de regresión realizado con las dosis de polvo de roca muestra una respuesta lineal creciente para las variables evaluadas.Rock dust dose and its effects on commercial performance of tomatoAbstract: Sustainable agriculture plays a very important role for continuous production of food, where it seeks to reduce the dependence of mineral fertilizers and the increase in the use of natural sources of nutrients, with low impact on the environment. The effect of

  15. Environmental equivalent dose due to radiation dispersed by the patient body in treatments with tomotherapy; Dosis equivalente ambiental debida a la radiacion dispersada por el cuerpo del paciente en tratamientos con tomoterapia

    Energy Technology Data Exchange (ETDEWEB)

    Esparza H, A.; Luna S, K. C.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Reyes R, E., E-mail: ange.es.he55@gmail.com [Universidad de Guanajuato, Division de Ciencias e Ingenieria, 37150 Leon, Guanajuato (Mexico)

    2017-09-15

    One of the important parameters of the design and evaluation of the bunker of a linear accelerator for radiotherapy is the dose at the point to be protected behind the barriers of the treatment room. In the case of primary barriers this dose is due to direct radiation and in the case of secondary barriers is the dose due to radiation that leaks from the head and the dose due to radiation scattered by the body of the patient. In Zacatecas the bunker in the oncology ward was designed for a linear accelerator of 18 MV, but an accelerator of the latest technology was installed, which is a linear accelerator of 6 MV for tomotherapy that has a better control of the applied dose. In order to determine the dose due to the scattered radiation that reaches the internal surfaces of the barriers of the room, thermoluminescent dosimeters (TLDs) of type 100 were used, which were placed on three occasions, in 9 points inside the bunker for periods of 7 days. During these periods, patients were routinely treated and treated for different tumors using different procedures. At each measurement point, 4 dosimeters were placed. The readings of the TLDs were used to calculate the environmental equivalent dose that was normalized to the applied dose. The highest doses were found on the surface of the accelerator and did not show symmetry, in the primary barriers the same doses were found and in the labyrinth the dose due to scattered radiation is influenced by the Compton dispersion that the photons scattered on the wall of the labyrinth background. (Author)

  16. Independent dose calculation in IMRT for the Tps Iplan using the Clarkson modified integral; Calculo independiente de dosis en IMRT para el TPS Iplan usando la integral modificada de Clarkson

    Energy Technology Data Exchange (ETDEWEB)

    Adrada, A.; Tello, Z.; Garrigo, E.; Venencia, D., E-mail: jorge.alberto.adrada@gmail.com [Instituto Privado de Radioterapia, Obispo Oro 423, X5000BFI Cordoba (Argentina)

    2014-08-15

    Intensity-Modulated Radiation Therapy (IMRT) treatments require a quality assurance (Q A) specific patient before delivery. These controls include the experimental verification in dose phantom of the total plan as well as dose distributions. The use of independent dose calculation (IDC) is used in 3D-Crt treatments; however its application in IMRT requires the implementation of an algorithm that allows considering a non-uniform intensity beam. The purpose of this work was to develop IDC software in IMRT with MLC using the algorithm proposed by Kung (Kung et al. 2000). The software was done using Matlab programming. The Clarkson modified integral was implemented on each flowing, applying concentric rings for the dose determination. From the integral of each field was calculated the dose anywhere. One time finished a planning; all data are exported to a phantom where a Q A plan is generated. On this is calculated the half dose in a representative volume of the ionization chamber and the dose at the center of it. Until now 230 IMRT planning were analyzed carried out ??in the treatment planning system (Tps) Iplan. For each one of them Q A plan was generated, were calculated and compared calculated dose with the Tps, IDC system and measurement with ionization chamber. The average difference between measured and calculated dose with the IDC system was 0.4% ± 2.2% [-6.8%, 6.4%]. The difference between the measured and the calculated doses by the pencil-beam algorithm (Pb) of Tps was 2.6% ± 1.41% [-2.0%, 5.6%] and with the Monte Carlo algorithm was 0.4% ± 1.5% [-4.9%, 3.7%]. The differences of the carried out software are comparable to the obtained with the ionization chamber and Tps in Monte Carlo mode. (author)

  17. Comparison of the deviation distribution in the doses administrated with and without mask in radiotherapeutic procedures; Comparacion de la distribucion de los desvios en las dosis administradas con y sin mascara en procedimientos radioterapicos

    Energy Technology Data Exchange (ETDEWEB)

    Santos Junior, S. dos; Ghilardi N, T. [Departamento de Fisica e Matematica FFCLRP-USP, Av. Bandeirantes, 3900 CEP 14040-901, Cidade Universitari, Ribeirao Preto, SP (Brazil)

    1998-12-31

    In order to guarantee that the error limit in the dose administration is inside of the recommended limit by the ICRU (the ICRU recommends that the doses administrated in radiotherapy must be inside of a total deviation {+-} 5 %), the radiotherapy services are maintaining quality control programs and dosimetry which guarantee that the equipment yield or source should be known with precision. The Quality Control Programs foresee moreover the radiation beam calibration dosimetry, the In vivo dosimetry for obtaining a greater control of the administered doses. At present it counts on greater devices for maintaining the deviations inside this margin, and one of them is the u se of masks. The present work was carried out on a Siemens equipment model Gammatron S-80 (Co-60) in the Radiotherapy Service of the Sao Paulo University Hospital where teletherapy procedures are realized. (Author)

  18. How much radiation dose, to whom? Long-term storage, surveillance, retrieval and long processes cause additional dose to employees; Wie viel Strahlendosis fuer wen? Lange Lagerung, Offenhaltung und ein langer Entsorgungsprozess bedeuten zusaetzliche Dosis fuer Beschaeftigte

    Energy Technology Data Exchange (ETDEWEB)

    Walther, Clemens [Hannover Univ. (Germany). Inst. fuer Radiooekologie und Strahlenschutz; Riemann, Moritz [Kiel Univ. (Germany). Lehrstuhl fuer Philosophie und Ethik der Umwelt

    2017-09-01

    In the case of final nuclear waste disposal there are concurrent interests with respect to radiation protection: The realization of a disposal option with minimum required follow-up care needs time causing additional radiation exposure for the employees, also the option of long-term storage, surveillance and retrieval possibilities cause additional dose to employees. The contribution discusses possible consideration of requests for the different options.

  19. Internal dose assessment in nuclear medicine: fetal doses due to radiopharmaceutical administration to the mother; Dosimetria interna en medicina nuclear: dosis absorbida en el feto por la administracion de radiofarmacos a la madre

    Energy Technology Data Exchange (ETDEWEB)

    Rojo, Ana M; Michelin, Severino C

    2004-07-01

    The objective of this publication is to present a guideline for the dose assessment through a comprehensive introduction of knowledge on ionizing radiation, radiation protection during pregnancy and fetal dosimetry for physician and other professionals involved in nuclear medicine practices. It contains tables with recommended dose estimates at all stages of pregnancy for many radiopharmaceuticals. Compounds for which some information was available regarding placental crossover are shown in shaded rows. It includes the most common diagnostic and therapy practices in nuclear medicine considering the four radioactive isotopes selected: {sup 99m}Tc, {sup 131}I, {sup 201}Tl and {sup 67}Ga. There is a special case included, it is when conception occurs after the iodine has been administered. In almost every case, the diagnostic benefit to the mother outweighs the risk of any irradiation of the fetus. However, there is one situation in which severe fetal injury can be incurred from administering a radiopharmaceutical to the mother, and that is use of iodine-131 therapy for ablation of the thyroid in cases of hyperthyroidism or carcinoma. Radioactive iodine readily crosses the placenta and concentrates in the fetal thyroid, where, because of its small organ mass, high radiation doses are received. (author)

  20. The Importance of Dosimetry to the Medical Management of Persons Accidentally Exposed to High Levels of Radiation; Le Role de la Dosimetrie Dans les Soins Medicaux a Donner aux Personnes Accidentellement Exposees a de Fortes Doses de Rayonnement; 0417 041d 0410 0427 0414 ; Importancia de la Dosimetria para el Tratamiento Medico de las Personas Accidentalmente Expuestas a Dosis Elevadas de Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, G. A.; Lushbaugh, C. C. [Medical Division, Oak Ridge Institute of Nuclear Studies (United States); Auxier, J. A. [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1965-06-15

    Radiation accidents continue to occur sporadically and it appears that there is no hope of eliminating them entirely. The management of patients exposed to large doses of radiation is constantly improving because of increasing ability to prevent and treat infection and to control haemorrhage. The possible effectiveness of temporary bone marrow grafts offers promise of a further reduction in mortality. The use of this growing biological information is closely related to, and to a large extent dependent upon, improvements in physical dosimetry for radiation accidents. (author) [French] Des accidents provoques par les rayonnements continuent a se produire de temps a autre et il ne semble guere que l'on puisse esperer les eliminer entierement. Toutefois, le traitement des sujets exposes a de fortes doses de rayonnement ne cesse de s'ameliorer; on parvient, en effet, dans une mesure croissante a empecher et a traiter l*infection ainsi qu'a arreter l'hemorragie. Comme la greffe temporaire de la moelle des os semble devoir donner des resultats, on peut s*attendre a une nouvelle reduction du taux de mortalite. L'application de ces connaissances biologiques sans cesse accrues est fonction, dans une large mesure, des ameliorations apportees a la dosimetrie physique des accidents nucleaires. (author) [Spanish] De vez en cuando se siguen produciendo accidentes de irradiacion y las perspectivas de evitarlos por completo parecen ser bastante remotas. El tratamiento de las victimas expuestas a dosis elevadas de radiaciones mejora constantemente debido a la creciente posibilidad de prevenir y tratar las infecciones, y de controlar las hemorragias. Tambien es posible que la eficacia de ios injertos temporales de medula osea se traduzca en una disminucion de la mortalidad. El aprovechamiento de estos conocimientos biologicos cada vez mas amplios guarda una estrecha relacion con los perfeccionamientos en materia de dosimetria fisica en caso de accidentes de irradiacion. (author

  1. Quantitative Evaluation of Dose-Response Relationships in Human Beings with Skeletal Burdens of Radium-226 and Radium-228; Evaluation Quantitative de la Relation entre Dose et Reponse chez des Sujets Ayant une Charge Squelettique de Radium 226 et Radium 228; 041a 041e 041b 0414 ; Evaluacion Cuantitativa de las Relaciones Dosis-Respuesta en Seres Humanos con Cargas de Radio-226 y Radio-228 en el Esqueleto

    Energy Technology Data Exchange (ETDEWEB)

    Maletskos, C. J.; Braun, A. G.; Shanahan, M. M.; Evans, R. D. [Radioactivity Center, Department of Physics. Massachusetts Institute of Technology, Cambridge, MA (United States)

    1964-11-15

    The 361 subjects with skeletal burdens of radium-226 and radium-228 studied in this laboratory now represent a large enough sample to allow the quantitative evaluation of the relationship between biological response and internal radiation dose. This report describes the procedures and preliminary results for such an analysis. The biological responses consist of a variety of-clinical results such as X-ray scores, tumours, fractures, urinalysis, haematology, blood chemistry, and protein electrophoresis. The internal radiation dose is calculated and expressed as the retained body burden in microcuries of minimum pure radium-226 equivalent (MPRE), cumulative rads, and cumulative rad-years. The first step in the analysis determines whether a relationship exists between a clinical parameter and the radiation dose. The determination is carried out by applying a contingency test, by means of which the actual data are compared with a postulated model of independence between the two variables. If no independence is found then some relationship is presumed to exist and a quantitative description of the dependence is obtained. Least-squares curve fitting procedures,are used to derive the coefficients and the, standard deviations of the coefficients of a power series. Such an expression provides an empirical quantitative description of the results along with a measure of their variability, is useful for impartial comparison with results from other laboratories, but implies no biophysical mechanism. The clinical results on these subjects are compared with results from control subjects with normal radium burdens, whether or not there is a dependence on radiation dose. Preliminary results indicate that the X-ray score shows the strongest and clearest correlation with internal radiation dose. There are definite indications of non-skeletal effects at higher burdens, particularly in lymphocyte count and sedimentation rate, which are similar to those obtained in the dog experiments at

  2. Control instrument for dose ratemeters

    International Nuclear Information System (INIS)

    Rutzki, B.

    1974-01-01

    The testing apparatus for the dose ratemeter has safety locking mechanisms for protection of the operating personnel allowing the apparatus to be opened only if the nuclear radiation source is shielded. For this purpose, the apparatus consists of a casing with an opening to be locked. The lock may be in the shape of a hollow cylinder matching with the likewise cylindrical wall of the casing through a ball bearing. The hollow-cylindrical part has an internal flange with a recess in which a shielding body in the shape of a roller is supported. The shielding body has a flattening on the jacket surface and penetrations for the nuclear radiation filled with absorbing material. Because of the eccentric bearing of the rotating shielding body with respect to the flange resp. the recess, the door connot be opened. Only after removal of the shielding block from the recess whereby the movement is caused from outside the casing by means of a knurling wheel, can the door be opened. Now, however, the shielding block is in the way of the beam from the nuclear radiation source and is shielding the door completely from it. (DG) [de

  3. Estudo comparativo entre uma e duas doses efetivas (DE95 de rocurônio para a intubação traqueal Estudio comparativo entre una y de los dosis efectivas (DE95 de rocuronio para la intubación traqueal A comparative study between one and two effective doses (ED95 of rocuronium for tracheal intubation

    Directory of Open Access Journals (Sweden)

    Luciano Carlos Gomes de Miranda

    2008-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Os bloqueadores neuromusculares (BNM são fármacos utilizados para produzir relaxamento da musculatura esquelética e facilitar a intubação traqueal (IT. A literatura descreve como sendo necessárias duas doses efetivas (DE95 o ideal para a IT. O rocurônio é um BNM não-despolarizante do tipo esteróide, sintético e de duração intermediária. O objetivo desse estudo foi avaliar e comparar as condições de intubação traqueal (IT, utilizando uma e duas doses efetivas (DE95 do rocurônio, seguindo os critérios da Conferência de Consenso de Copenhague. MÉTODO: Foram avaliados 60 pacientes divididos aleatoriamente em dois grupos de 30, de ambos os sexos, idades entre 20 e 60 anos, estado físico ASA I e II, Mallampati 1 e 2, índice de massa corporal (IMC JUSTIFICATIVA Y OBJETIVOS: Los bloqueadores neuromusculares (BNM son fármacos utilizados para producir el relajamiento de la musculatura esquelética y facilitar la intubación traqueal (IT. La literatura describe que son necesarias de los dosis efectivas (DE95 lo ideal para la IT. El rocuronio es un BNM no despolarizador del tipo esteroide, sintético y de duración intermedia. El objetivo de este estudio fue evaluar y comparar las condiciones de intubación traqueal (IT, utilizando una y de los dosis efectivas (DE95 del rocuronio, secundando los criterios de la Conferencia de Consenso de Copenhague. MÉTODO: Se estudiaron 60 pacientes divididos aleatoriamente en 2 grupos de 30, de ambos sexos, edades entre 20 y 60 años, estado físico ASA I y II, Mallampati 1 y 2, índice de masa corporal (IMC BACKGROUND AND OBJECTIVES: Neuromuscular blockers (NMB are used to induce relaxation of skeletal muscles and facilitate tracheal intubation (TI. According to the literature, two effective doses (ED95 of NMB are ideal for TI. Rocuronium is a steroid-type, synthetic, non-depolarizing neuromuscular blocker of medium duration. The objective of this study was to evaluate

  4. Fuji Amulet 1000 MS mammography system and radiation dose rate at the image receptor; El mamografo Fuji Amulet 1000 MS y la tasa de dosis de radiacion en el receptor de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Rivas Ballarin, M. A.; Ruiz Manzano, P.; Jimenez Albericio, J.

    2011-07-01

    Measurements for commissioning and for establishing the performance reference level of Fuji Amulet 1000 MS mammography digital system yielded conflicting results regarding compliance with the defined tolerances for dose rate at the receiver input defined at the Spanish Protocol for Quality Control in Diagnostic X-Ray Systems. It was found that this result is due to the pulsed nature of the radiation emitted and it is concluded by recommending that in these cases dose rate has to be measured at tube loadings typical of clinical examinations (50 mAs or higher). (Author) 2 refs.

  5. Measurement of dose to skin using TLD of several radiodiagnostic studies in San Jose, Costa Rica; Medicion de dosis a piel utilizando TLD de varios estudios radiodiagnosticos en San Jose, Costa Rica

    Energy Technology Data Exchange (ETDEWEB)

    Mora, P. [Laboratorio de Fisica Nuclear Aplicada, Escuela de Fisica, Universidad de Costa Rica, San Jose (Costa Rica)

    1998-12-31

    It is quantified the radiation doses on skin for several radiodiagnostic studies in patients of the Calderon Guardia Hospital in San Jose, Costa Rica at the period October 1997-September 1998 using thermoluminescent dosemeters TLD 100. The crystals receive the decoction standard procedures and they are arranged at the middle of the irradiation field. For a total of 973 radiodiagnostic studies it was found that the dose on skin in mGy are: 2.09 for thorax AP/AP, 5.33 for thorax LAT, 5.35 for skull AP/PA, 2.98 for skull LAT, 10.74 for abdomen, hips and pelvis, 6.20 for spines AP, 9.35 for spines LAT, 11.48 for lumbar columns AP, 29.99 for lumbar columns LAT and 6.87 for intravenous skin diagrams (first plate ap). It is produced thus the first reference bank for the national hospitals, which is compared with the orientation levels of doses for IAEA. Recommendations to diminish the collective doses through quality control programs are discussed, taking as goal to have got radiographs of excellent diagnostic quality, but with the less possible doses. (Author)

  6. Tratamiento del bocio tóxico difuso con 131I en dosis de 80 µCi/g de tejido tiroideo Treatment of diffuse toxic goiter with 131I at doses of 80 µCi/g of thyroid tissue

    Directory of Open Access Journals (Sweden)

    Francisco Ochoa Torres

    2004-12-01

    Full Text Available El 131I ha demostrado ser la terapéutica más eficaz en el tratamiento del bocio tóxico difuso (BTD. Sin embargo, no existe consenso sobre la dosis a administrar: fija o de acuerdo con la actividad funcional del tiroides y su tamaño. Con el fin de evaluar los resultados terapéuticos con una dosis de 80 µCi/g de tejido tiroideo, estimado por palpación y sin tener en cuenta la actividad funcional del tiroides, se estudiaron 61 pacientes diagnosticados por la clínica, así como las determinaciones de TSH y T4 total en edades entre 20 y 80 años, de uno y otro sexos, con tamaño de la glándula de más de 30 g y si habían recibido o no propiltiouracilo (PTU previamente. El seguimiento postratamiento se realizó cada 2 meses durante 3 años por el mismo especialista y con iguales procederes. La eficacia del tratamiento con la primera dosis fue de 85,2 %. La frecuencia de hipotiroidismo a los 3 años de evolución fue de 29,5. La edad del paciente, el sexo, el tamaño del bocio y el tratamiento con PTU no influyeron en la respuesta a este. Las ventajas mostradas por el método fueron: una eficacia alta, la dosis de 131I se calcula con facilidad, es fácil de aplicar, disminuye el costo al no tener que realizar valoración del estado funcional de la glándula y reduce las consultas.131I has proved to be the most efficient therapeutics in the treatment of diffuse toxic goiter (DTG. However, there is no consensus on the dose to be administered: fixed dose or according to the functional activity of the thyroid and its size. In order to evaluate the therapeutical results at a dose of 80 Ci/g of thyroid tissue, estimated by palpation and without having into account the functional activity of thyroid and wether they had received propylthiouracil (PTU previously , 61 patients diagnosed by the clinic, as well as determinations of TSH and total T4, were studied in individuals aged 20-80 of both sexes, with a thyroid size over 30 g. The posoperative

  7. Levels of dose in head exams by TAC in Cuba. Interrelation with parameters of image quality; Niveles de dosis en examenes de craneo por TAC en Cuba. Interrelacion con parametros de calidad de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Fleitas Estevez, Ileana; Mora Machado, Roxana de la; Guevara Ferrer, Carmen R. [Centro de Control Estatal de Equipos Medicos (CCEEM), La Habana (Cuba)

    2001-07-01

    In the last years an increment in the use of Computer Tomography (CT) has been observed as an efficient diagnostic method. On the other hand, this type of study involves high doses levels which are imparted to the patient. In Cuba, there are not reported values of that doses levels for typical CT studies. The National Control Center for Medical Devices has been developing for several years investigations for knowing the guidance doses levels for different examinations in radiodiagnosis, taking into account the recommendations made for The International Basic Safety Standards, which have been adopted in Cuba. This paper presents an study of imparted doses for typical head examinations in 10 CT scanners (6 are helical and 3 axial technology). Values of CTDI, CTDIw (weighed) and nCTDIw (weighted and normalized) were calculated. The relation between CTDI at surface and CTDI in the center of the phantom for the highest slice width was calculated for each CT scanner. Others parameters, such as CT number and its special uniformity, noise, contrast scale, sensibility profiles, MTF evaluation, table movement and alignment between lasers and radiation field, have also obtained. These parameters were evaluated by means of the manufacturer's phantom (Siemens). (author)

  8. Converting dose distributions into tumour control probability

    International Nuclear Information System (INIS)

    Nahum, A.E.

    1996-01-01

    The endpoints in radiotherapy that are truly of relevance are not dose distributions but the probability of local control, sometimes known as the Tumour Control Probability (TCP) and the Probability of Normal Tissue Complications (NTCP). A model for the estimation of TCP based on simple radiobiological considerations is described. It is shown that incorporation of inter-patient heterogeneity into the radiosensitivity parameter a through s a can result in a clinically realistic slope for the dose-response curve. The model is applied to inhomogeneous target dose distributions in order to demonstrate the relationship between dose uniformity and s a . The consequences of varying clonogenic density are also explored. Finally the model is applied to the target-volume DVHs for patients in a clinical trial of conformal pelvic radiotherapy; the effect of dose inhomogeneities on distributions of TCP are shown as well as the potential benefits of customizing the target dose according to normal-tissue DVHs. (author). 37 refs, 9 figs

  9. Converting dose distributions into tumour control probability

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, A E [The Royal Marsden Hospital, London (United Kingdom). Joint Dept. of Physics

    1996-08-01

    The endpoints in radiotherapy that are truly of relevance are not dose distributions but the probability of local control, sometimes known as the Tumour Control Probability (TCP) and the Probability of Normal Tissue Complications (NTCP). A model for the estimation of TCP based on simple radiobiological considerations is described. It is shown that incorporation of inter-patient heterogeneity into the radiosensitivity parameter a through s{sub a} can result in a clinically realistic slope for the dose-response curve. The model is applied to inhomogeneous target dose distributions in order to demonstrate the relationship between dose uniformity and s{sub a}. The consequences of varying clonogenic density are also explored. Finally the model is applied to the target-volume DVHs for patients in a clinical trial of conformal pelvic radiotherapy; the effect of dose inhomogeneities on distributions of TCP are shown as well as the potential benefits of customizing the target dose according to normal-tissue DVHs. (author). 37 refs, 9 figs.

  10. Proposal for the classification of closed indoor spaces according to concentration of {sup 222}Rn and the possible doses involved; Propuesta para la clasificacion de los espacios interiores cerrados por su concentracion de Rn-222 y las posibles dosis involucradas

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, Marco; Leon, Kety; Martinez, Jorge [Direccion de Servicios, Instituto Peruano de Energia Nuclear, Lima (Peru)

    2014-07-01

    Radon causes more than 50 % of total dose from natural background radiation per year. It is widely demonstrated the capacity of radon to induce lung cancer in people exposed to this radioactive gas for long periods. Radon emerges continuously from materials that constitute soils, building materials and minerals present in our natural environment, all over the world. In our country, it is necessary to get better regulations to control the exposition of people to this gas inside buildings, dwellings and facilities where people spend their time. Our country has very simple and scarce regulations on this respect. At present, national regulations about radon are adaptations of recommendations and guides published for international organizations but without national studies or statistics to give realistic support to those rules. This work propose a classification for closed spaces where people live and work in this country taking into consideration their {sup 222}Rn concentration and probable doses involved. (authors).

  11. Curva dose-resposta do exercício em hipertensos: análise do número de sessões para efeito hipotensor Curva dosis-respuesta del ejercicio en hipertensos: análisis del número de sesiones para efecto hipotensor Dose-response curve to exercise in hypertensive individuals: analysis of the number of sessions to the hypotensive effect

    Directory of Open Access Journals (Sweden)

    Paulo Ricardo Nazário Viecili

    2009-05-01

    Full Text Available FUNDAMENTO: O efeito do exercício na pressão arterial já é conhecido, entretanto a curva dose-resposta do efeito hipotensor do exercício em hipertensos ainda não está clara. OBJETIVO: Avaliar a curva dose-resposta do número de sessões necessárias para causar efeito hipotensor em indivíduos hipertensos. MÉTODOS: Participaram deste estudo 88 indivíduos, com 58 ± 11 anos, divididos em grupo experimental (GE - composto de 48 integrantes de um programa de exercício físico (PEF de 3 meses, 3 vezes por semana, com 40' de exercício aeróbio a 70% do VO2máx e exercícios musculares a 40% da CVM - e grupo-controle (GC - 40 indivíduos que não realizaram PEF. As pressões arteriais sistólica (PAS e diastólica (PAD foram mensuradas antes de cada uma das 36 sessões no GE e avaliadas por MAPA no GC. Observaram-se as diferenças na PA, o índice de variação (D% e o efeito hipotensor máximo (EHM% entre as sessões. Os dados foram expressos por M ± DP, e usou-se teste t e correlação, considerando p FUNDAMENTO: Ya se conoce el efecto del ejercicio en la presión arterial, sin embargo, la curva dosis-respuesta del efecto hipotensor del ejercicio en hipertensos no está aclarada aún. OBJETIVO: Evaluar la curva dosis-respuesta del número de sesiones necesarias para causar efecto hipotensor en individuos hipertensos. MÉTODOS: El estudio estaba conformado por 88 individuos, con 58 ± 11 años, divididos en grupo experimental (GE -conformado por 48 integrantes de un programa de ejercicio físico (PEF de tres meses, tres veces por semana, con 40' de ejercicio aerobio al 70% del VO2máx y ejercicios musculares al 40% de la capacidad voluntaria máxima (CVM; y grupo-control (GC con 40 individuos que no realizaron el PEF. Se midieron las presiones arteriales sistólica (PAS y diastólica (PAD del GE antes de cada una de las 36 sesiones y en el GC se las evaluaron por monitoreo ambulatorio de presión arterial (MAPA. Se observaron las

  12. Dose calibrator user and quality control guide

    International Nuclear Information System (INIS)

    Blanchis, Philippe; Amiot, Marie-Noelle; Moune, Muriel; Bellanger, Anne-Christine; Chauvenet, Bruno; Verdeau, Eric; Gardin, Isabelle; Martineau, Antoine; Ricard, Marcel; Caselles, Olivier; Guilhem, Marie-Therese; Hapdey, Sebastien; Lisbona, Albert; Bonnot-Lours, Sophie; Dumont, Agnes; Lemercier, Valerie; Rizzo-Padoin, Nathalie

    2006-06-01

    This document is a practical guide for the use and control of dose calibrators which are instruments used for radioactivity measurements. After a recall of the calibrator operation principle, the authors describe all the operations performed on this apparatus all along its lifetime: controls to be performed for device acceptance, aspects to be addressed during installation, controls to be performed before any use, daily controls, more detailed controls, and operations to be performed for maintenance, in case of dysfunctions or for re-calibration

  13. Dose measurement received by the exposed occupationally personnel of the nuclear medicine department of the INCan; Medicion de dosis recibida por el personal ocupacionalmente expuesto del departamento de medicina nuclear del INCan

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez U, N. A.

    2011-07-01

    Personal dose equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of Instituto Nacional de Cancerologia (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 67}Ga, {sup 99m}Tc, {sup 111}In and {sup 201}Tl with main gamma emission energies between 93 and 511 keV. Dosemeter calibration was performed at the metrology department of Instituto Nacional de Investigaciones Nucleares, Mexico. Every occupational worker used dark containers with three dosemeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and a maximum of 9 mSv. Two of the 16 members of the OEW receive high estimated annual doses (6-9 mSv), other 5 receive annual doses between 3 and 5 mSv, other 3 between 2.5 and 3 mSv, and the rest receive dose values consistent with background radiation. These values are dependent on their daily activities and it is clear that the maximum doses are received by those OEW who perform nursing duties and receive radiopharmaceuticals for daily use. All obtained values are well within the established annual OEW dose limit stated in the General Regulation of Radiological Protection, Mexico (50 mSv) as well as within the lower limit recommended by the International Commission on Radiation Protection, report no. 60 (20 mSv). Additionally, consistence was found between measured monthly values and those reported by the firm that performs the monthly service. These results verify the adequate compliance of the NMD at INCan, Mexico with the standards given by

  14. Automatic dose-rate controlling equipment

    International Nuclear Information System (INIS)

    Szasz, T.; Nagy Czirok, Cs.; Batki, L.; Antal, S.

    1977-01-01

    The patent of a dose-rate controlling equipment that can be attached to X-ray image-amplifiers is presented. In the new equipment the current of the photocatode of the image-amplifier is led into the regulating unit, which controls the X-ray generator automatically. The advantages of the equipment are the following: it can be simply attached to any type of X-ray image-amplifier, it accomplishes fast and sensitive regulation, it makes possible the control of both the mA and the kV values, it is attached to the most reliable point of the image-transmission chain. (L.E.)

  15. Efeitos hemodinâmicos e renais da injeção de doses elevadas de clonidina no espaço peridural do cão Efectos hemodinámicos y renales de la inyección de dosis elevadas de clonidina en el espacio peridural del perro Hemodynamic and renal effects of high epidural clonidine doses in dogs

    Directory of Open Access Journals (Sweden)

    Nilson Camargo Roso

    2005-06-01

    ébito cardíaco e aumento da relação depuração de para-aminohipurato de sódio/débito cardíaco. CONCLUSÕES: Nas condições realizadas e nas doses empregadas, pode-se concluir que a clonidina não promoveu alteração da função renal, mas diminuiu valores hemodinâmicos (freqüência e débito cardíaco.JUSTIFICATIVA Y OBJETIVOS: No existen estudios que relaten las repercusiones renales determinadas por la inyección de dosis elevadas de clonidina en el espacio peridural. La finalidad del estudio fue evaluar los efectos hemodinámicos y renales determinados por la inyección de dosis elevadas de clonidina en el espacio peridural del perro. MÉTODO: Veinte animales anestesiados con tiopental sódico y fentanil fueron distribuidos eventualmente y de forma doblemente encubierta en dos grupos: Grupo 1 ó placebo (n = 10, que recibió 0,2 mL.kg-1 de solución fisiológica, y Grupo 2 ó clonidina (n = 10, que recibió 0,2 mL.kg-1 de una solución conteniendo 50 µg.mL-1 de clonidina, en el espacio peridural. Fueron evaluados los siguientes parámetros hemodinámicos: frecuencia cardiaca (FC: lat.min-1; presión arterial media (PAM: mmHg; presión de la arteria pulmonar ocluida (PAOP: mmHg; débito cardíaco (DC: L.min-1; volumen sistólico (VS: mL; también, los siguientes parámetros de la función renal fueron evaluados: flujo sanguíneo renal (FSR: mL.min-1; resistencia vascular renal (RVR: mmHg.mL-1.min; volumen urinario minuto (VUM: mL.min-1; depuración de creatinina (DCr: mL.min-1; depuración de para-aminohipurato (DPAH: mL.min-1; fracción de filtración (FF; depuración de sodio (DNa: mL.min-1; depuración de potasio (DK: mL.min-1; excreción fraccionaria de sodio (EFNa: %; excreción urinaria de sodio (UNaV: µEq.min-1; excreción urinaria de potasio (UKV: µEq.min-1. El experimento consistió en tres momentos de 20 minutos cada uno. Los datos fueron colectados a los 10 minutos de cada momento y la diuresis, en el inicio y al final de cada momento. Al t

  16. Comparative study of patient doses calculated with two methods for breast digital tomosynthesis; Estudio de los valores de dosis a pacientes en examenes de tomosintesis de mama estimados con dos metodos distintos

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, M.; Chevalier, M.; Calzado, A.; Garayo, J.; Valverde, J.

    2015-07-01

    In this study, the average glandular doses (DG) delivered in breast tomosynthesis examinations were estimated over a sample of 150 patients using two different methods. In method 1, the conversion factors air-kerma to DG used were those tabulated by Dance et al. and in method 2 were the ones from Feng et al. The protocol for the examination followed in the unit of this study consists in two views per breast, each view composed by a 2D acquisition and a tomosynthesis scan (3D). The resulting DG values from both methods present statistically significant differences (p=0.02) for the 2D modality and were similar for the 3D scan (p=0.22). The estimated median value of DG for the most frequent breasts (thicknesses between 50 and 60 mm) delivered in a single 3D acquisition is 1.7 mGy (36% and 17% higher than the value for the 2D mode estimated with each method) which lies far below the tolerances established by the Spanish Protocol Quality Control in Radiodiagnostic (2011). The total DG for a tomosynthesis examination (6.0 mGy) is a factor 2.4 higher than the dose delivered in a 2D examination with two views (method 1). (Author)

  17. Computerization of effluent management and external dose calculation using the 'ODCM' methodology applied to Almaraz-NPP; Mecanizacion informatica de la gestion de efluentes y calculo de dosis al exterior usando la metodologia MCDE aplicada a C.N. Almaraz

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Gutierrez, M E [Empresarios Agrupados, A.I.E., Madrid (Spain); Sustacha Duo, D [C.N. Almaraz, Caceres (Spain)

    1993-12-15

    The ODCM (Offsite Dose Calculation Manual), the official operational document for all nuclear power plants develops the details for the technical specifications for discharges and governs their practical application. The use of ODCM methodology for managing and controlling data associated with radioactive discharges, as well as the subsequent processing of this data to assess the radiological impact, requires and generates a large volume of data, which demands the frequent application of laborious and complex calculation processes, making computerization necessary. The computer application created for Almaraz NPP has the capacity to store and manage data on all discharges, evaluate their effects, presents reports and copies the information to be sent periodically to the CSN (Spanish Nuclear Regulatory Commission) on a magnetic tape. The radiological impact of an actual or possible discharge can be evaluated at anytime and, furthermore, general or particular reports and graphs on the discharges and doses over time can be readily obtained. The application is run on a personal computer under a relational database management system. This interactive application is based on menus and windows. (author)

  18. Dose preparatória de atracúrio: aferição da fadiga no músculo orbicular do olho e condições de intubação orotraqueal Dosis preparatoria de atracurio: comparación de la fatiga en el músculo orbicular del ojo y condiciones de intubación orotraqueal Priming dose of atracurium: measuring orbicularis oculi muscle fade and tracheal intubation conditions

    Directory of Open Access Journals (Sweden)

    Giovani de Figueiredo Locks

    2003-12-01

    clinicamente aceitáveis (p > 0,05. CONCLUSÕES: A dose preparatória de atracúrio (0,02 mg.kg-1 não causa fadiga no músculo orbicular do olho e não há diferença entre aguardar 5 ou 7 minutos como intervalo entre as doses do bloqueador neuromuscular.JUSTIFICATIVA Y OBJETIVOS: El método de la dosis preparatoria (priming principle consiste en la inyección de una pequeña dosis del bloqueador neuromuscular minutos antes de la administración de lo que queda de la dosis preconizada para intubación traqueal para encortar el inicio de acción de los bloqueadores neuromusculares (BNM adespolarizantes. Existe, sin embargo, posibilidad de fatiga muscular y broncoaspiración. De especial interés para las maniobras de intubación orotraqueal y protección de las vías aéreas, son los músculos de la laringe. Como su monitorización directa impone dificultades técnicas, se demostró que el músculo orbicular del ojo presenta correlación con los músculos laríngeos cuanto a la sensibilidad a los BNM. El objetivo de esta pesquisa es evaluar si hay fatiga del músculo orbicular ocular después del uso de la dosis preparatoria de atracúrio y comparar las condiciones clínicas de intubación traqueal después de dos intervalos entre las dosis. MÉTODO: Fueron seleccionados 35 pacientes adultos, estado físico ASA I o II, sin factores de riesgo para broncoaspiración, sometidos a cirugía electiva. Fue inducida anestesia general con alfentanil y propofol y el paciente fue ventilado manualmente bajo máscara. En seguida, fueron posicionados los electrodos para estimular el ramo temporal del nervio facial y el transductor de aceleración en el músculo orbicular del ojo. Se administró dosis preparatoria de atracúrio (0,02 mg.kg-1 y la relación T4/T1 fue evaluada a cada minuto durante 5 minutos en 20 casos (G1 y 7 minutos en 13 casos (G2. Después de este intervalo, se administró la dosis complementar de atracúrio (0,5 mg.kg-1 y se procedió a la intubación orotraqueal despu

  19. Influence of energy dependence GafChromic XR-RV3 movies to the extent of skin dose; Influencia de la dependencia energetica de las peliculas Gafchromic XR-RV3 en la medida de dosis en piel

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Gomez, L. C.; Gilarranz Moreno, R.; Rot San Juan, M. J.; Delgado Rodriguez, J. M.; Adaimi Hernandez, P.; Milanes Gaillet, A.

    2013-07-01

    In this work we have evaluated uncertainties by comparing the calculated dose with films from a calibration reference with dose measurements ionization with chamber using beams in clinical conditions. (Author)

  20. Spatial dependence and origin of the ambient dose due to neutron activation processes in linear accelerators; Dependencia espacial y origen de la dosis ambiental debeda a procesos de activacion neutronica en aceleradores lineales

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Egea, E.; Sanchez Carrascal, M.; Torres Pozas, S.; Monja Ray, P. de la; Perez Molina, J. L.; Madan Rodriguez, C.; Luque Japon, L.; Morera Molina, A.; Hernandez Perez, A.; Barquero Bravo, Y.; Morengo Pedagna, I.; Oliva Gordillo, M. C.; Martin Olivar, R.

    2011-07-01

    In order to try to determine the high dose in the bunker of a Linear Accelerator clinical use trying to measure the spatial dependence of the same from the isocenter to gateway to the board cheeking to establish the origin of it. This dose measurements performed with an ionization chamber at different locations inside the bunker after an irradiation of 400 Monitor Units verifying the dose rate per minute for an hour, and accumulating the dose received during that period of time.

  1. Analysis of the testicular dose in patients undergoing radiotherapy for carcinoma of the prostate; Analisis de las dosis testiculares en pacientes sometidos a tratamiento radioterapico de carcinoma de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Bejar Navarro, M. J.; Ordonez Marquez, J.; Hervas Moron, A.; Alvarez Rodriguez, S.; Garcia-Galloway, E.; Sanchez Casanueva, R.; Polo Rubio, A.; Rodriguez-Patron, R.; Yanowsky, K.; Gomez Dos Santos, V.

    2013-07-01

    The objectives of this work are: -Studying comparatively the doses received in testes in patients undergoing radiotherapy of prostate carcinoma with external beam radiation and brachytherapy of low rate using I-125 seeds. -Compare doses due to images of verification using Cone Beam CT (CBCT), with doses of radiotherapy treatment itself. -Determine the seminal alterations and cytogenetic after treatment with ionizing radiation (RTE or BQT) in patients diagnosed with prostate cancer and its relation with testicular dose. (Author)

  2. Critical Consideration of the Methods of Calculation Used in the Evaluation of the Absorbed Dose to the Skin in Cases of External Contamination; Observations Critiques sur les Methodes de Calcul Utilisees pour l'Evaluacion de la Dose Absorbee par la Peau en Cas de Contamination Externe; 041a 0420 0414 ; Observaciones Criticas Sobre los Metodos de Calculo Utilizados para Evaluar la Dosis Absorbida por la Piel en Caso de Contaminacion Externa

    Energy Technology Data Exchange (ETDEWEB)

    Casnati, E.; Breuer, F. [Gruppo di Dosimetria e Standardizzazione, CNEN, Centro di Studi Nucleari della Casaccia, Rome (Italy)

    1965-06-15

    resultats permettent de conclure que, dans la geometrie consideree, on peut determiner par des formules de type exponentielle, d'une part la dose imputable aux rayons beta et, d'autre part, la dose imputable aux rayons gamma pour la couche basale de la peau;- on peut considerer les resultats comme acceptables du point de vue de la radioprotection. (author) [Spanish] La dosis absorbida, suele calcularse mediante la formula de Loevinger cuando se trate de particulas beta mientras que para las radiaciones electromagneticas se recurre habitualmente a una formula exponencial. En la memoria, los autores se proponen examinar si en el caso de contaminacion cutanea puede considerarse satisfactorio el empleo de una formula exponencial (la formula de Rossi y Ellis) y de una formula similar para calcular la dosis beta y la dosis gamma, respectivamente. Con este objeto, se han comparado los resultados.obtenidos para este tipo especial de geometria por medio de la formula de Rossi y Ellis y con la formula de Loevinger para partfculas beta; por lo que respecta a la radiacion gamma, se han comparado los valores obtenidos mediante la formula exponencial y con otras dos formulas mas complejas, que se ajustan a las condiciones de acumulacion fotonica maxima nula, respectivamente. Estos resultados permiten sacar la conclusion de que, dadas las condiciones geometricas de que se trata, pueden determinarse mediante la formula de tipo exponencial tanto la dosis de radiacion beta como la dosis de radiacion gamma en la dermis. Los resultados son aceptables desde el punto de vista de la proteccion radiologica. (author) [Russian] Obychno pri podschete dozy ispol'zuetsja formula Laevingera dlja chastic i jeksponencial'naja formula dlja jelektromagnitnyh izluchenij. V doklade rassmatrivaetsja vopros o tom, mozhno li schitat' udovletvoritel'nym ispol'zovanie jeksponencial'noj formuly (podobnoj formule Rossi i Jellisa) i analogichnyh formul pri podschete sootvetstvenno beta- i gamma-dozy. S jetoj cel

  3. Patient Safety in Drug Therapy and the Influence of the Prescription in Dose Errors Seguridad del paciente en la terapéutica medicamentosa y la influencia de la prescripción médica en los errores de dosis Segurança do paciente na terapêutica medicamentosa e a influência da prescrição médica nos erros de dose

    Directory of Open Access Journals (Sweden)

    Fernanda Raphael Escobar Gimenes

    2010-12-01

    Full Text Available The aims of this study were to analyze the redaction of the prescription in dose errors that occurred in general medical units of five Brazilian hospitals and to identify the pharmacological classes involved in these errors. This was a descriptive study that used secondary data obtained from a multicenter study conducted in 2005. The population consisted of 1,425 medication errors and the sample of 215 dose errors. Of these, 44.2% occurred in hospital E. The presence of acronyms and/or abbreviations was verified in 96.3% of prescriptions; absence of the patient registration in 54.4%; absence of posology in 18.1%; and omission of date of 0.9%. With respect to medication type, 16.8% were bronchodilators; 16.3% were analgesics; 12.1%, antihypertensives; and 8.4% were antibiotics. The absence of posology in the prescriptions may facilitate the administration of the wrong dose, resulting in inefficiency of the treatment, compromising the quality of care provided to hospitalized patients.Los objetivos fueron analizar la redacción de la prescripción médica en los errores de dosis ocurridos en unidades de clínica médica de cinco hospitales brasileños e identificar las clases farmacológicas envueltas en esos errores. Se trata de estudio descriptivo que utilizó datos secundarios obtenidos de en una investigación multicéntrica realizada en 2005. La población fue compuesta de 1.425 errores de medicación y la muestra por 215 errores de dosis. De estos, 44,2% ocurrieron en el hospital E. Se verificó: presencia de siglas y/o abreviaturas en 96,3% de las prescripciones; ausencia del registro del paciente en 54,4%; falta de posología en 18,1%, y omisión de la fecha en 0,9%. Con relación al tipo de medicamento, 16,8% eran broncodilatadores; 16,3% eran analgésicos; 12,1%, antihipertensivos y 8,4% eran antimicrobianos. La ausencia de la posología en las prescripciones puede favorecer la administración de dosis equivocadas, resultando en

  4. Determination of eye lens doses and identification of risk groups among radiation exposed workers. An Austrian pilot study; Bestimmung der Augenlinsen-Dosis und Identifizierung von Risikogruppen bei beruflich strahlenexponierten Personen. Eine Pilotstudie in Oesterreich

    Energy Technology Data Exchange (ETDEWEB)

    Stadtmann, H.; Hranitzky, C.; Willer, H. [Seibersdorf Labor GmbH, Seibersdorf (Austria). Radiation Protection Dosimetry; Strebl, F.; Ernst, G. [Seibersdorf Labor GmbH, Seibersdorf (Austria). Radiation Safety and Applications; Aspek, W. [Allgemeine Unfallversicherungsanstalt (AUVA), Wien (Austria). Abt. Unfallverhuetung und Berufskrankheitenbekaempfung (HUB)

    2015-07-01

    On European level, in 2014 the dose limit for the lens of the eye of radiation exposed workers has been reduced from 150 to 20 mSv per year (2013/59/Euratom). Data about eye lens exposition measured under realistic operational conditions of Austrian radiation exposed workers is sparse and there is no information to verify, if all professional groups identified to be at risk for elevated eye doses will remain below the new annual dose limit. Therefore, financed by the Austrian Workers Compensation Board, AUVA, a pilot study has been initiated to answer this question. Based on published information professional groups of radiation exposed workers and operational tasks with an enhanced risk of elevated eye lens doses have been identified. By dosimetric measurements with volunteers (forehead dose meters and parallel measurements with whole-body TL-dose meters above and under the lead apron) realistic lens doses will be estimated during selected radiation exposed tasks. Comparison of yielded doses will show whether a TLD outside the apron could serve as an alternative to forehead dose meters dedicated to measure eye lens doses. Measurements with leaded protective eyewear based on IEC61331 yield results for lead equivalent in good agreement with manufacturers' information. Results for eye lens doses determined by use of a RANDO head phantom and a standardized phantom simulating a body in a typical exposition situation for interventional radiologists show that wearing of leaded goggles allows for a 90% dose reduction. Under such conditions the eye lens dose is dominated by backscatter and stray radiation from the operator's head and patient body. This has to be considered for the evaluation of protective effectiveness for leaded eye wear.

  5. Effect of the dose of oral Hydrocortisone on growth rate during long-term treatment of children with salt losing congenital adrenal hyperplasia Efecto de la dosis oral de hidrocortisona sobre la velocidad de crecimiento en niños con la forma perdedora de sodio de la hiperplasia suprarrenal congénita

    Directory of Open Access Journals (Sweden)

    M. Ciaccio

    2002-12-01

    Full Text Available The effect of the dose of oral hydrocortisone on stature growth rate of patients with the salt losing form of congenital adrenal hyperplasia and adequate electrolyte balance was here assessed. Thirty patients (21 girls and 9 boys were followed longitudinally for 0.52 to 8.64 years, between chronological ages 0.35 and 8.64 years. Nine consecutive periods (Ps of follow up were defined in order to compare two auxological parameters, height (H at the end of a follow up P and DH standard deviation score (SDS. According to growth rate during a particular P, two types of Ps were defined: Ps with DH SDS > -0.5 (Group 1, satisfactory growth rate and Ps with DH SDS = or 18 mg/m²/day and grew poorly, but they were able to recover, at least temporarily, when the dose was adjusted during the following years.El propósito del estudio fue evaluar el efecto de la dosis dehidrocortisona sobre la velocidad de crecimiento en pacientes con la forma perdedora de sodio de la hiperplasia suprarrenal congénita, en adecuado balance hidroelectrolítico. Se siguieron en forma longitudinal 30 pacientes (21 niñas y 9 niños durante 0.52 a 8.64 años, con edades cronológicas entre 0.35 y 8.64 años. Se definieron 9 períodos (P consecutivos de seguimiento para comparar: el score de desviación estándar (SDS para talla (T al final del P y el DSDS T (diferencia en el SDS de talla. Se definieron dos tipos de Ps: P con DSDS T > -0.5 (Grupo 1, velocidad de crecimiento satisfactoria y P con DSDS = o 18 mg/m²/día y crecieron poco. Sin embargo, la talla se recuperó cuando la dosis fue ajustada en años posteriores.

  6. Calibration curve to establish the exposure dose at Co{sup 60} gamma radiation; Curva de calibracion para establecer dosis de exposicion a radiacion gamma de Co{sup 60}

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C; Brena V, M [Departamento de Biologia, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico)

    2000-07-01

    The biological dosimetry is an adequate method for the dose determination in cases of overexposure to ionizing radiation or doubt of the dose obtained by physical methods. It is based in the aberrations analysis produced in the chromosomes. The behavior of leisure in chromosomes is of dose-response type and it has been generated curves in distinct laboratories. Next is presented the curve for gamma radiation produced in the National Institute of Nuclear Research (ININ) laboratory. (Author)

  7. Calculation of absorbed doses in sphere volumes around the Mammosite using the Monte Carlo simulation code MCNPX; Calculo de dosis absorbida en volumenes esfericos alrededor del Mammosite utilizando el codigo de simulacion Monte Carlo MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E. L. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico)

    2008-07-01

    The objective of this study is to investigate the changes observed in the absorbed doses in mammary gland tissue when irradiated with a equipment of high dose rate known as Mammosite and introducing material resources contrary to the tissue that constitutes the mammary gland. The modeling study is performed with the code MCNPX, 2005 version, the equipment and the mammary gland and calculating the absorbed doses in tissue when introduced small volumes of air or calcium in the system. (Author)

  8. Method for evaluation of doses from ingestion of polonium, bismuth and lead as natural radioactive material(NORM); Metodo de evaluacion de dosis por ingestion de polonio, bismuto y plomo como materiales radiactivos naturales

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Vanessa; Puerta, Anselmo; Morales, Javier, E-mail: vpenam@ullal.edu.co, E-mail: japuerta@unal.edu.co, E-mail: jmorales@unal.cdu.co [Universidad Nacional de Colombia, Medellin (Colombia). Grupo de Fisica Radiologica

    2013-07-01

    In this work was carried out an evaluation of dose from ingestion of radioactive daughters of radon (lead, bismuth and polonium), taking into account ages from three months up to adult men, using the new model of the human alimentary tract HATM and methodology of calculating doses proposed by the ICRP publication 103, which allows the estimation of dose based on the concentration of the radionuclide present in the diet or in the water of consumption.

  9. Absolute dose measurement Gafchromic R EBT2 movies. Case Study of Kaposis sarcoma; Medida de dosis absoluta con peliculas Gafchromic EBT2. Caso practico de un sarcoma de Kaposi

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, L.; Moral, F. del; Meilan, E.; Azevedo Gomes, J. C. de; Tejeiro Garcia, A. G.; Andrade Alvarez, B.; Vazquez, J.; Nieto, I.; Medal, D.; Lopez Medina, A.; Francisco, S.; Salgado, M.; Munoz, V.

    2011-07-01

    Because of its high spatial resolution, low energy dependence and good response over a wide energy range, EBT2 Gafchromic films are widely used in many applications in radiotherapy for measuring relative dose. Despite being the most common use can be used to measure absolute dose. This text is an example of using films as EBT2 for in vivo absolute dose in a Kaposis sarcoma.

  10. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy; Preparacion y determinacion del kerma de fuentes de iridio-192 de baja tasa de dosis para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045-1, Salazar, Esrado de Mexico, D.F. (Mexico)

    2000-07-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 {+-} 0.531 M Bq and kerma in air 0.03200 {+-} 0.00006 m Gy m/h A. (Author)

  11. Assessment of the doses received by patients with pacemakers who have received treatment of external radiotherapy; Evaluacion de la dosis recibida por pacientes con marcapasos que han recibido tratamiento de radioterapia externa

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Alarcon, C.; Carrasco Herrera, M. A.; Vicent Grandado, D.; Gutierrez Ramos, S. M.; Herrador Cordoba, M.

    2013-07-01

    The objective of this study is to estimate with system planning, TPS the dose that would receive the pacemaker and its comparison with the dose received during the treatment a film radiochromic EBT2 located in the area where it is located. (Author)

  12. Adapting protocols of CT imaging in a pediatric emergency department. Evaluation of image quality and dose; Adaptacion de los protocolos de adquisicion de imagenes de TC pediatricos en un servicio de urgencia. Valoracion de la calidad de imagen y dosis

    Energy Technology Data Exchange (ETDEWEB)

    Batista Arce, A.; Gonzalez Lopez, S.; Catalan Acosta, A.; Casares Magaz, O.; Hernandez Armas, O.; Hernandez Armas, J.

    2011-07-01

    The purpose of this study was to assess qualitatively the picture quality in relation to the radiation dose delivered in CT studies of computer tomograph Pediatric Emergency Department of Hospital Universitario de Canarias (HUC) in order to optimize the technical parameters used these radiological examinations so as to obtain optimal image quality at the lowest possible dose.

  13. Class solution to decrease rectal dose in prostate radiotherapy treatments 3D-CRT; Solucion de clase para disminuir dosis en recto en tratamientos de prostata con radioterapia 3D-CRT

    Energy Technology Data Exchange (ETDEWEB)

    Andres Rodriguez, C.; Tortosa Oliver, R.; Alonso Hernandez, D.; Mari Palacios, A.; Castillo Belmonte, A. del

    2011-07-01

    This paper contains a method developed in our center with conventional 3D radiotherapy techniques to increase the dose conformation around the target volume in prostate cancer treatments significantly reduced the doses to the rectum. To evaluate the goodness of the method, the results are compared with two classical techniques of treatment.

  14. Analysis of the dose-response relationship observed in Sprekelia, Petunia and Impatiens treated with gamma radiation; Analisis de la relacion dosis-respuesta observada en Sprekelia, Petunia e Impatiens tratadas con radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, J [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The present investigation was carried out in order to verifying if it is possible to establish one or a dose range that directly not at random produces a specific effect independently of the species that is treated. The results show that this can be possible if the ranges settle down based on the specific stocking lethal dose for each specie. (Author)

  15. Calculations of received dose for different points in the enrichment uranium oxide warehouse at 4%; Calculos de dosis recibida para diferentes puntos en el almacen de oxido de uranio enriquecido al 4%

    Energy Technology Data Exchange (ETDEWEB)

    Alonso V, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1990-06-15

    In order to verifying that the received dose so much inside as outside of the warehouse of enriched uranium dioxide to 4% it doesn't represent risk to the personnel, the modelling of this and the corresponding calculations for the extreme case of dose at contact are made. (Author)

  16. Human population doses: Comparative analysis of CREAM code results with currently computer codes of Nuclear Regulatory Authority; Dosis en la poblacion: comparacion de los resultados del codigo CREAM con resultados de modelos vigentes en la ARN

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Jimenez, Maria Teresa; Curti, Adriana [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)]. E-mail: mtalonso@sede.arn.gov.ar; acurti@sede.arn.gov.ar

    2001-07-01

    The Nuclear Regulatory Authority is performing an analysis with PC CREAM, developed at the NRPB, for updating computer programs and models used for calculating the transfer of radionuclides through the environment. For CREAM dose assessment verification for local scenarios, this paper presents a comparison of population doses assessed with the computer codes used nowadays and with CREAM, for unitary releases of main radionuclides in nuclear power plant discharges. The results of atmospheric dispersion processes and the transfer of radionuclides through the environment for local scenarios are analysed. The programs used are PLUME for atmospheric dispersion, FARMLAND for the transfer of radionuclides into foodstuffs following atmospheric deposition in the terrestrial environment and ASSESSOR for individual and collective dose assessments.This paper presents the general assumptions made for dose assessments. The results show some differences between doses due to differences in models, in the complexity level of the same models, or in parameters. (author)

  17. Efecto del consumo de diferentes dosis de café filtrado sobre los niveles plasmáticos de homocisteína y presión arterial en un grupo de voluntarios sanos Effect of consumption of different doses of filtered coffee on homocysteine plasma levels and blood pressure in a group of healthy volunteers

    Directory of Open Access Journals (Sweden)

    Gloria M Agudelo O

    2008-04-01

    Full Text Available No está claro si el consumo de café afecta la presión arterial y los niveles de homocisteína. El objetivo fue determinar el cambio en las concentraciones plasmáticas de homocisteína y presión arterial en un grupo de voluntarios sanos. Se realizó un estudio prospectivo, clínico controlado, en el que se conformaron cuatro grupos de 29 sujetos cada uno, quienes, durante un período de seis semanas, se sometieron al consumo diario de café filtrado. El grupo 1 no consumió café, el grupo 2 consumió 200 mL de café, el grupo 3 400 mL y el 4 600 mL. Antes de la intervención se midieron: presión arterial, homocisteína, índice arterial, ácido fólico eritrocitario y vitaminas B12 y B6. Al final de la intervención, se tomó la presión arterial y se midió la concentración de homocisteína. Los resultados mostraron grupos sin diferencias significativas en las condiciones basales. Después de la intervención, el cambio en los valores de homocisteína entre los grupos, no mostró diferencia significativa y permanecieron dentro de los valores de referencia (p = 0,098. El cambio en los niveles de presión arterial sistólica y diastólica, no fue significativo (p=0,510 y 0,430 respectivamente. En conclusión, el consumo de diferentes dosis de café filtrado, no mostró cambios significativos en los niveles séricos de homocisteína como tampoco en los niveles de presión arterial sistólica y diastólica en un grupo de sujetos sanos normotensos; en el grupo que se abstuvo de tomar café, no disminuyeron de manera significativa los niveles de homocisteína y presión arterial.It is not clear if coffee consumption affects blood pressure and homocysteine levels. The objective of this study was to determine the variations in homocysteine plasma levels and blood pressure in a group of healthy volunteers. A prospective controlled clinical trial was performed; four groups of 29 patients each one were comprised and they were submitted to filtered

  18. Dose in sensitive organs during the prostate treatment with a {sup 60}Co unit; Dosis en organos sensibles durante el tratamiento de prostata con una unidad de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Apdo. Postal 336, 98000 Zacatecas (Mexico); Navarro B, J. A. [Universidad Autonoma de Zacatecas, Unidad Academica de Fisica, Carretera a la Bufa s/n, Zacatecas (Mexico); Perez A, M. L.; Perez L, L. H., E-mail: fermineutron@yahoo.com [Instituto Zacatecano del Tumor, A. C., Lago de la Encantada No. 294, Fracc. Lomas del Lago, Zacatecas (Mexico)

    2012-10-15

    The absorbed dose by the bladder, the rectum and the gland thyroid was measured during a treatment applied for prostate cancer by means of a Cobalt 60 unit. The dose was measured using thermoluminescent dosimeters of the type TLD 100, with the values of the absorbed the values of the effective dose were calculated and was determined the probability of the development of a secondary cancer. Because these measurements cannot be made -in vivo- a phantom or mannequin was built with water that represents the hip and part of the torso of the human body and to represent the neck was used polyethylene. The study was carried out in the Instituto Zacatecano del Tumor that has a -cobalt bomb- which is used to treat oncology patients, during the phantom irradiation a dose of 200 c Gy was applied of this dose the bladder received 96.7%, the rectum 100.8% and the gland thyroid 0.3%. The dose received by the rectum and the bladder is due to the therapeutic beam while the dose received by the thyroid is due to the dispersed radiation by the phantom. The probability that in these organs a new neoplasm is developed is of 0.033% for the bladder, 0.157% for the rectum and 7.8 x 10{sup -5}% for the thyroid case. (Author)

  19. First results of dose to patient in CT extracted with an automatic registration system; Primeros resultados de dosis a paciente en TC extraidas con un sistema automatico de registro

    Energy Technology Data Exchange (ETDEWEB)

    Minambres Moro, A.; Fernandez Leton, P.; Garcia Ruiz-Zorilla, J.; Perez Moreno, J. M.; Zucca Aparicio, D.

    2013-07-01

    Radiation protection of the patient in computed tomography (CT) is a priority for several reasons: the dose received during a scan is relatively high, is the diagnostic mode with greater contribution to dose to patient collective and the frequency of completion of TC is increasing rapidly the past few years. On the other hand, are currently beginning to commercially offer automated registration of dose to patient receiving dosimetric parameters of all scans performed on the equipment connected to the system. In this communication the first results are presented from two TC connected to an automatic system of this kind recently installed at our Center. (Author)

  20. Independent procedure of checking dose calculations using an independent calculus algorithm; Verificacion independiente de los parametros de planificacion, histogramas dosis volumen, y parametros radiobioligocs mediante el uso de una hoja de calculo automatizada

    Energy Technology Data Exchange (ETDEWEB)

    Perez Rozos, A.; Jerez Sainz, I.; Carrasco Rodriguez, J. L.

    2006-07-01

    In radiotherapy it is recommended the use of an independent procedure of checking dose calculations, in order to verify the main treatment planning system and double check every patient dosimetry. In this work we present and automatic spreadsheet that import data from planning system using IMPAC/RTP format and verify monitor unit calculation using an independent calculus algorithm. Additionally, it perform a personalized analysis of dose volume histograms and several radiobiological parameters like TCP and NTCP. Finally, the application automatically generate a clinical dosimetry report for every patient, including treatment fields, fractionation, independent check results, dose volume analysis, and first day forms. (Author)

  1. Study of external exposure doses received by Cuban population due to terrestrial component of the environmental radiation sources; Estudio de las dosis por exposicion externa que recibe la poblacion cubana debidas a la componente terrestre de la radiacion ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Zerquera, Juan Tomas; Prendes Alonso, Miguel [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba); Brigido Flores, Osvaldo [Laboratorio de Vigilancia Radiologica Ambiental de Camaguey (Cuba); Hernandez Perez, Alberto [Laboratorio de Vigilancia Radiologica Ambiental de Oriente, Holguin (Cuba)

    2001-07-01

    The work presents the results of the study carried out to evaluate the doses that the Cuban population receives for the external exposition to the terrestrial component of the environmental sources of radiation. Starting from the carried out measurements it was possible to estimate the doses effective representative annual stockings that the Cuban population receives for external exposition to the terrestrial radiation, considering the permanency in indoors and outdoors. The dose received due to this component was 180{+-}14 mSv/year. These values are in the range of those reported internationally. (author)

  2. Determining the optimal dose of Fenton reagent in a leachate treatment by Fenton-adsorption; Determinacion de la dosis optima de reactivo Fenton en un tratamiento de lixiviados por Fenton-adsorcion

    Energy Technology Data Exchange (ETDEWEB)

    Mendez Novelo, Roger Ivan; Pietrogiovanna Bronca, Jose Alfredo; Santos Ocampo, Beatriz; Sauri Riancho, Maria Rosa; Giacoman Vallejos, German; Castillo Borges, Elba Rene [Universidad Autonoma de Yucatan, Facultad de Ingenieria, Merida, Yucatan (Mexico)]. E-mail: mnovelo@uady.mx

    2010-07-01

    tipo Fenton-adsorcion con el que se obtuvieron mejores resultados que con otros tratamientos fisicoquimicos o biologicos reportados en la literatura. El proceso Fenton consiste en tratar la carga contaminante con una combinacion de H{sub 2}O{sub 2} y FeSO4 en condiciones acidas. Se evaluo si la filtracion de los lodos producidos durante el proceso Fenton es un proceso mas eficiente que la sedimentacion. Se determino el tiempo de contacto optimo de la oxidacion Fenton, asi como la dosis optima de los reactivos usados en funcion de la DQO del lixiviado, mediante la determinacion de las mejores relaciones [Fe{sup 2+}]/[H{sub 2}O{sub 2}] y [DQO]/[H{sub 2}O{sub 2}]. Despues de optimizar el proceso, se filtraron las muestras oxidadas y se ensayo la adsorcion mediante columnas empacadas con carbon activado granular. Se concluyo que el lodo generado por el proceso Fenton se remueve mas eficientemente mediante filtracion que por sedimentacion. Los tiempos de contacto optimos fueron de 5 min para la remocion de la DQO y una hora para la remocion de color, tiempo elegido para proteger el carbon activado. Las mejores relaciones para [Fe{sup 2+}]/[H{sub 2}O{sub 2}] y [DQO]/[H{sub 2}O{sub 2}] fueron 0.6 y 9, respectivamente. La eficiencia maxima de remocion despues del proceso de adsorcion fue de 98.9 % para la DQO y 100 % para el color. El indice de biodegradabilidad final alcanzado despues de las pruebas de Fenton-adsorcion fue de 0.24.

  3. A remotely operated drug delivery system with dose control

    KAUST Repository

    Yi, Ying; Kosel, Jü rgen

    2017-01-01

    include an effective actuation stimulus and a controllable dose release mechanism. This work focuses on remotely powering an implantable drug delivery system and providing a high degree of control over the released dose. This is accomplished by integration

  4. Calculation of dose due to exposure internal in the services of nuclear medicine of Peru; Calculo de dosis debida a la exposicion interna en los servicios de medicina nuclear del Peru

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, S.; Zapata, L.; Cardenas, A.; Velasquez, M.

    2013-07-01

    The objective of this work is to improve the radiation protection of workers occupationally exposed to open source of nuclear medicine services and train those responsible for radiation protection of such installations to carry a comprehensive record of doses. (Author)

  5. Protocol and results of the estimates of equivalent dose in utero at 500 scans radiology; Protocolo y resultados de las estimaciones de dosis equivalente en utero en 500 exploraciones de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Gago Gomez, P.; Hurtado Sanchez, A.; Gomez Cores, S.; Sierra Diaz, F.; Gonzalez Ruiz, C.; Gomez Calvar, R.; Herranz Crespo, R.

    2011-07-01

    According to Royal Decree 1976/1999, laying down the criteria of quality in diagnostic radiology, it is mandatory in utero dose estimation in the case of pregnant patients subjected to X-ray diagnostic examinations.

  6. Tail's Entropy and dose of critical annihilation: a new view of the problem radiobiological; Entropia de Tsallis y dosis de aniquilacion critica: una nueva vision del problema radiobiologico

    Energy Technology Data Exchange (ETDEWEB)

    Sotolongo Grau, O.; Rodriguez Perez, D.; Antoranz, J. C.

    2011-07-01

    The aim of this paper is to present a model based on a minimum radiobiological physical hypotheses containing known models as special cases, allowing to define operations of addition and multiplication dose survival probabilities to fit the experimental data.

  7. Dose estimation using different ways of irradiation in a group of infants from zones affected by the Chernobyl accident; Estimacion de dosis por diferentes vias de irradiacion en un grupo de infantes de areas afectadas por el accidente de Chernobil

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Suarez, R; Jova Sed, L; Corripio, J A [Centro de Proteccion e Higiene de las Radiaciones, La Habana (Cuba)

    1994-12-31

    A dosimetry study is done to 4506 children from the Republic of Ukraine (69,3%), Belarus (8,1%) and Russian (22,5%) from 659 village and with ages between 1 and 17 years old. The study covers several stages. We can mention, for example, the dose estimation of iodine 121 in thyroids, the dose estimation for contamination with strontium 90 in the field and the calculation of the effective dose integrated in 70 years for the incorporation of cesium 137 in the body of the children, assuming a model of chronic incorporation. The estimation of the effective dose due to the strontium 90 was limited to a small group of 1314 children of those zones where the values of surface contamination of the field with this radionuclide are know.

  8. Comparison in the determination of absorbed dose by biological and physical methods to patients in treatment of cardiac intervention; Comparacion en la determinacion de dosis absorbida por metodos biologicos y fisicos a pacientes en tratamiento de intervencionismo cardiaco

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Arceo M, C., E-mail: citlali.guerrero@inin.gob.mx [ININ, Departamento de Biologia, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    The use of less invasive procedures, lower risk and quick recovery as cardiac intervention have proven to be an efficient alternative to reestablish the correct bloodstream of the patient. In this case the patient is subjected to values of absorbed dose above to which is subjected in a study with X-rays for medical diagnosis, and this can cause radiation injuries to the skin. The target organ, in this case can be exposed to doses of 2 Gy above. Different methods to estimate the dose were use, physical by Radiochromic film, as biological by dicentric analysis. Both methods provided additional information demonstrating thus the risk in the target organ and the patient. The most reliable biological indicator of exposure to ionizing radiation is the study of chromosomal aberrations, specifically dicentric in human lymphocytes. This test allowed establishing the exposure dose depending of the damage. (Author)

  9. Determination of dose to patient in different teams of TC and assessment with international reference levels; Determinacion de dosis a pacientes en diferentes equipos de TC y evaluacion con niveles de referencia internacionales

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Morales, C.; Fernandez lara, A. A.; Buades Forner, M. J.; Tobarra Gonzalez, B. M.

    2013-07-01

    The increase in CT studies and the differences observed between the different equipment used in our hospital prompted us to determine the doses to patients in different studies and check the results obtained with the reference values published internationally. (Author)

  10. Comparison of dose and image quality in protocols abdominal CT using high an low KVP; Comparacion de dosis y calidad de imagen en protocolos abdominales de TC utilizando alto y bajo kilovoltaje

    Energy Technology Data Exchange (ETDEWEB)

    Mas Munoz, I.; Alejo Luque, L.; Corredoira Silva, E.; Sanchez Munoz, F. J.; Serrada Hierro, A.

    2013-07-01

    This paper compares quantitatively low kV Protocol with the conventional Protocol of abdomen, analysing the image quality with objective physical parameters and calculating the corresponding dummy dose reduction. (Author)

  11. Calculating of radiation doses in rutinary unloads of liquid wastes from Laguna Verde nuclear power plant.; Calculo de las dosis de radiacion debidas a las descargas rutinarias de desechos liquidos de la central nucleoelectrica de Laguna Verde.

    Energy Technology Data Exchange (ETDEWEB)

    Molina, G

    1986-12-31

    Utilization of nuclear energy to generate electricity is increasingly being used to replace fossil fuels. During operation of nuclear power plants, radioactive materials are produced, a small fraction of which are released to environment as liquid or gaseous effluents. Estimation of radiation doses caused by effluents release has three purposes. During design phase of a nuclear station it is useful to adapt the wastes treatment systems to acceptable limits. During licensing phase, the regulator organism verifies the design of nuclear station effectuating estimation of doses. Finally, during operation, before every unload of radioactive effluents, radiation doses should be evaluated in order to fulfill technical specifications limiting the release of radioactive materials to environment. 1. To perform calculations of individual doses due to liquid radioactive effluents unload in units 1 and 2 of Laguna Verde nuclear power plant (In licensing phase). 2. To perform a parametric study of the effect of unload recirculation over individual dose, since recirculation has two principal effects: thermodynamical effects in nuclear station and radioactivity concentration; the last can affect the fullfilment of dose limits. 3. To perform the calculation of collective doses causes by unloads of liquid effluents within a radius of 80 km of the plant caused by unload of liquid radioactive effluents during normal operation and does not include doses during accident conditions. In Mexico the organism in charge of regulation of peaceful uses of nuclear energy is Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) and for Laguna Verde licensing, the regulations of the country who manufactured the reactor (USA). In Appendix C, units are explained.

  12. Jaws calibration method to get a homogeneous distribution of dose in the junction of hemi fields; Metodo de calibracion de mandibulas para conseguir una distribucion homogenea de dosis en la zona de union de hemicampos

    Energy Technology Data Exchange (ETDEWEB)

    Cenizo de Castro, E.; Garcia Pareja, S.; Moreno Saiz, C.; Hernandez Rodriguez, R.; Bodineau Gil, C.; Martin-Viera Cueto, J. A.

    2011-07-01

    Hemi fields treatments are widely used in radiotherapy. Because the tolerance established for the positioning of each jaw is 1 mm, may be cases of overlap or separation of up to 2 mm. This implies heterogeneity of doses up to 40% in the joint area. This paper presents an accurate method of calibration of the jaws so as to obtain homogeneous dose distributions when using this type of treatment. (Author)

  13. Absorbed doses profiles vs Synovia tissue depth for the Y-90 and P-32 used in radiosynoviortesis treatment; Perfiles de dosis absorbida vs profundidad de tejido sinovial para el Y-90 y el P-32 empleados en tratamiento de radiosinoviortesis

    Energy Technology Data Exchange (ETDEWEB)

    Torres B, M.B.; Ayra P, F.E. [Centro de Isotopos (Cuba); Garcia R, E. [Hospital General Docente Enrique Cabrera (Cuba); Cornejo D, N. [CPHR, (Cuba); Yoriyaz, H. [IPEN, (Brazil)]. e-mail: nestor@cphr.edu.cu

    2006-07-01

    The radiosynoviortesis treatment has been used during more of 40 years as an alternative to the chemical and surgical synovectomy to alleviate the pain and to reduce the inflammation in suffered patients of rheumatic arthropathies, haemophilic arthropathies and other articulation disorders. It consists on the injection of radioactive isotopes inside a synovial cavity. For to evaluate the dosimetry of the radiosynoviortesis treatment is of great interest to know the absorbed dose in the volume of the target (synovia). The precise calculation of the absorbed dose in the inflamed synovia it is difficult, for numerous reasons, since the same one will depend on the thickness of the synovial membrane, the size of the articular space, the structure of the synovial membrane, the distribution in the articulation, the nature of the articular liquid, etc. Also the presence of the bone and the articular cartilage, components also of the articulation, it even complicated more the calculations. The method used to evaluate the dosimetry in radioactive synovectomy is known as the Monte Carlo method. The objective of our work consists on estimating with the Monte Carlo code MCNP4B the absorbed dose of the Y-90 and the P-32 in the depth of the synovial tissue. The results are presented as absorbed dose for injected millicurie (Gy/mCi) versus depth of synovial tissue. The simulation one carries out keeping in mind several synovia areas, of 50 cm{sup 2} to 250 cm{sup 2} keeping in mind three states of progression of the illness. Those obtained values of absorbed dose using the MCNP4B code will allow to introduce in our country an optimized method of dose prescription to the patient, to treat the rheumatic arthritis in medium and big articulations using the Y-90 and the P-32, eliminating the fixed doses and fixed radionuclides for each articulation like it happens in many clinics of Europe, as well as the empiric doses. (Author)

  14. Characterization by Monte Carlo of the dose after a glass shield lead for gamma ray; Caracterizacion por Monte Carlo de la dosis tras un blindaje de vidrio de plomo para rayos gamma

    Energy Technology Data Exchange (ETDEWEB)

    Esteve Sanchez, S.; Gil Conde, M.; Contreras Gonzalez, J. L.; Rosado, J.; Pazyi, V.

    2013-07-01

    When a gamma-ray beam crosses the border between two media characterized by atomic number very different is they produce effects on the distribution of doses near the border difficult to predict with simple models. The case of rays gamma affecting a lead glass is particularly interesting for its application to shielding of common use. interested in studying the importance of the residual dose after the shield. (Author)

  15. Dose evaluation in occupationally exposed workers through dosimeters ring and wrist type with an anthropomorphic phantom; Evaluacion de la dosis en trabajadores ocupacionalmente expuestos a traves de dosimetros tipo anillo y de muneca con un fantoma antropomorfico

    Energy Technology Data Exchange (ETDEWEB)

    Palma, R.; Gastelo, E. [Univesidad Nacional Pedro Ruiz Gallo, Huamachuco, Lambayeque (Peru); Paucar, R.; Tolentino, D.; Herrera, J. [Complejo Hospitalario San Pablo, Lima (Peru); Armas, D., E-mail: fispalma@hotmail.com [Consorcio Proxtronics del Pacifico S. A. C., Cal. Manuela Estacio Mza. D1-2 Lote 13, San Miguel, Lima (Peru)

    2014-08-15

    In the Nuclear Medicine service of the Clinica San Pablo (Peru), the occupationally exposed workers carried out the preparation and administration of radiopharmaceuticals to patients, so it is vital to measure the equivalent dose to the hands during the procedures in order to optimize the exposure to the ionizing radiation and execute the Radiological Safety Regulation (D.S. No. 009-97-Em) and the standard IR 002.2012 of radiation protection and safety in nuclear medicine. In this paper was designed and built a hand anthropomorphic phantom made of paraffin following the description given for the standard man, later were placed dosimeters ring and wrist type UD-807 model, Panasonic brand. Then we proceeded to irradiate using vial containers of Tc-99 and I-131. The obtained results showed the difference between the equivalent dose obtained among the ring and wrist dosimeter also getting a dose of 153 mSv /year when working with {sup 99m}Tc and of 61 mSv /year when working with iodine-131. Was also demonstrated that the ring dosimeter shows the average dose received in the hand with less dispersion. It was found that under the national regulation on Requirements of Radiation Protection and Nuclear Safety in Medicine article 63, indicates that higher doses of 150 mSv /year the occupationally exposed workers should have hand dosimetry. Finally the individual dose limit of 500 mSv /year in extremities can be overcome if adequate radiation protection standards do not apply. (author)

  16. Caracterização da dose letal mínima por irradiação gama para Penicillium citrinum Characterization of minimum lethal dosis of gama irradiation to Penicillium citrinum

    Directory of Open Access Journals (Sweden)

    A. N. Norberg

    1993-12-01

    Full Text Available O uso das radiações ionizantes na destruição de microrganismos responsáveis pela deterioração de alimentos ou causadores de infecções ou toxinfecções alimentares, constituiu-se aplicação da energia nuclear, para fins verdadeiramente pacíficos. Penicillium citrinum é um fungo produtor de micotoxinas, responsáveis por intoxicações em humanos e animais que se utilizam de alimentos contaminados. Há escassez de informações sobre a resistência do P. citrinum à irradiação gama; assim esta pesquisa objetivou determinar a dose letal por irradiação gama para esse microrganismo. Foram irradiadas 76 suspensões, contendo aproximadamente 100.000 esporos por mililitro, com doses entre 0,2 e 2,2 KGy (KiloGray, sendo os sobreviventes re-irradiados com doses até 3,0 KGy. O fungo foi totalmente destruído com dose de 2,2 KGy. P. citrinum descendentes dos sobreviventes de 2,0 KGy, quando re-irradiados também foram totalmente destruídos com dose de 2,2 KGy. Observou-se um aumento da resistência às doses mais baixas em relação ao fungo não irradiadoThe use of nuclear power through radiation for the destruction of microrganisms which cause food decay, and toxicosis, is specifically for peaceful purposes. Penicillium citrinum is a fungus which produce mycotoxins responsible for intoxication in humans and animals as a result of eating contaminated food. There is little informations on the resistance of P. citrinum to radiation. The objective of this research is to determine the lethal dose of gama radiation for these microrganisms. Seventy six suspensions containing approximately 100,000 spores/ml received a dose of radiation between 0.2 and 2.2 KGy (KiloGray, being one sample still alive re-irradiated with doses up to 3.0 KGy. The fungus were totally destroyed with a 2.2 KGy. Seventy six suspensions containing approximately 100,000 spores/ml received a dose of radiation between 0.2 and 2.2 KGy, being one sample still alive re

  17. Regression models in the determination of the absorbed dose with extrapolation chamber for ophthalmological applicators; Modelos de regresion en la determinacion de la dosis absorbida con camara de extrapolacion para aplicadores oftalmologicos

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T; Morales P, R

    1992-06-15

    The absorbed dose for equivalent soft tissue is determined,it is imparted by ophthalmologic applicators, ({sup 90} Sr/{sup 90} Y, 1850 MBq) using an extrapolation chamber of variable electrodes; when estimating the slope of the extrapolation curve using a simple lineal regression model is observed that the dose values are underestimated from 17.7 percent up to a 20.4 percent in relation to the estimate of this dose by means of a regression model polynomial two grade, at the same time are observed an improvement in the standard error for the quadratic model until in 50%. Finally the global uncertainty of the dose is presented, taking into account the reproducibility of the experimental arrangement. As conclusion it can infers that in experimental arrangements where the source is to contact with the extrapolation chamber, it was recommended to substitute the lineal regression model by the quadratic regression model, in the determination of the slope of the extrapolation curve, for more exact and accurate measurements of the absorbed dose. (Author)

  18. Determination of the dose in eyes lens by TLD, in PET/CT by technicians in PET/CT service; Determinacion de la dosis en cristalino por medio de TLD, en personal tecnico de servicio PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Marino, Emiliano A., E-mail: eam.marino@gmail.com [Universidad Nacional de Cuyo (UNC), Rio Negro (Argentina). Instituto Balseiro; Arenas, German M. [Fundacion Escuela de Medicina Nuclear (FUESMEN), Mendoza (Argentina)

    2013-11-01

    This work was supported, on the one hand, in a part of the project ORAMED which consisted of a design of a TLD dosimeter for measurements of Hp (3) in areas close to the lens, for interventional radiology physicians. On the other hand, Berhens work proposes using calibrated TLDs Hp (0.07) and Hp (10) to estimate Hp (3) crystal. This resulted in dosimeters calibrated using Hp (10) slab, and mount them on glasses, to estimate the dose to the lens of the technical staff of the Service PET / CT. The value obtained 29mSv/year of Lens Dose Equivalent exceeds the recommended limit. We also demonstrate that, under the current working conditions, the values of Hp (3) reported from whole body dosimeter does not represent faithfully the lens dose.

  19. Determination of the dose equivalents due to neutrons produced during therapeutic irradiations with a Varian CLINAC 2500; Determinacion de la dosis equivalente debida a neutrones producidos durante irradiaciones terapeuticas con un Varian CLINAC 2500

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo, Ricardo E [Centro de Investigacion y de Estudios Avanzados del IPN, Unidad Merida, Yucatan (Mexico)

    1991-07-01

    This experiment it was designed to quantify that so important it is the dose equivalent deposited by the neutron flow that is generated by photonuclear reactions during therapeutic irradiations with X rays of produced high-energy for an accelerator Varian CLINAC 2500. This accelerator type is routinely used in the Department of Radiotherapy of the Hospital of the University of Wisconsin, E.U. The equivalent dose was measured in diverse towns of the room of irradiations using the activation of thin sheets of gold put in the center of plastic recipients full with water. In general, the recipients were 1 m or more than the floor and at distances still bigger than the walls. The irradiations were made using photons with the highest energy that you can select with this team - 24 MeV. The due equivalent dose to neutrons taken place here by the energy photons used they were measured and reported. (author)

  20. Calculation of dose distribution in the patient for verification of plans of intensity modulated radiation therapy; Calculo de la distribucion de dosis en el paciente para la verificacion de planes de radioterapia de intensidad modulada

    Energy Technology Data Exchange (ETDEWEB)

    Perez Moreno, J. M.; Zucca Aparicio, D.; Garcia Ruiz-Zorrila, J.; Fernandez Leton, J. P.; Minambres Moro, A.

    2013-07-01

    The precision in the delivery of radiation therapy treatments intensity modulated depends on, among other things, of the proper administration of the sequence of radiation calculated on the planning system. In recent years the electronic devices of imaging portal have shown as a useful tool for the measurement of dose distribution with high resolution. An algorithm has been developed to calculate the distribution of dose in the patient's Anatomy, using the accelerator as measuring equipment electronic imaging of portal In this way the acceptance criteria can be changed in the dosimetry verifications pretreatment of radiation therapy treatments, from those based on evaluation of gamma index to others based on the evaluation of the distribution of dose in the patient. (Author)

  1. Dose absorbed in adults and children thyroid due to the I{sup 123} using the dosimetry MIRD and Marinelli; Dosis absorbida en tiroides de adultos y ninos debido al I{sup 123} utilizando las dosimetrias MIRD y Marinelli

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.; Castillo, C.; Cabrera, C.; Sarachaga, R.; Castaneda, J. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Ciudad Universitaria, Trujillo (Peru); Diaz, E., E-mail: marvva@hotmail.com [Universidade Federal do Rio Grande do Sul, Av. Paulo Gamma 110, Bairro Farropilhas, Porto Alegre, RS 90040-060 (Brazil)

    2014-08-15

    Using the dosimetry MIRD, and representation Cristy-Eckerman in the thyroid gland and organs of their bio-kinetics when I{sup 123} (Iodine) is used, the study demonstrates that the absorbed dose by the gland of an adult, children, and newly born, is their auto-dose, independent of the compartments number of their bio-kinetics. The dosimetric contributions of the organs of their bio-kinetics are insignificant. Their results are not significantly different to those obtained by the formalism MARINELLI (auto-dose) when it uses a sphere like glandular representation. In consequence, the kinetic model corresponding to the glandular representation decreases to a compartment, where the gland can also be represented like a sphere. (Author)

  2. Valorization of the GAFCHROMIC XR-R film for radiation dose estimation in the skin; Valoracion de las peliculas Gafchromic XR-R para estimacion de dosis a piel en ''ablacion por radiofrecuencia''

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Garcia, M.; Otero Martinez, C.; Camino, X. M.; Sendon del Rio, J. R.; Luna Vega, V.; Lobato Busto, R.; Mosquera Sueiro, J.; Pombar Camean, M.

    2006-07-01

    The adequacy of the couple formed by the GAFCHROMIC XR-R film and the MICROTEK Scan Maker 8700 for skin dose determination has been evaluated. The main advantages are the ease of use the films, since it can be manipulated without special care and the ability to archive it in the dosimetric history of the patient. The main limiting factors coming from the scanner are the reproducibility over time and noise in the digitization; it is shown that this last component can be minimized at the cost of resolution. From the film itself, the limiting factors are the inter and intra film uniformity. Contributing an 6,5% to the overall uncertainty in dose determination. Overall, it has been shown that skin dose determination is possible with this film with an uncertainty below 10%. (Author)

  3. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  4. Dose calculations for a simplified Mammosite system with the Monte Carlo Penelope and MCNPX simulation codes; Calculos de dosis para un sistema Mammosite simplificado con los codigos de simulacion Monte Carlo PENELOPE y MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L.; Varon T, C.F.; Pedraza N, R. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: elrc@nuclear.inin.mx

    2007-07-01

    The treatment of the breast cancer at early stages is of vital importance. For that, most of the investigations are dedicated to the early detection of the suffering and their treatment. As investigation consequence and clinical practice, in 2002 it was developed in U.S.A. an irradiation system of high dose rate known as Mammosite. In this work we carry out dose calculations for a simplified Mammosite system with the Monte Carlo Penelope simulation code and MCNPX, varying the concentration of the contrast material that it is used in the one. (Author)

  5. Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop

    Energy Technology Data Exchange (ETDEWEB)

    Tedjasari, R S; Lubis, E [Radioactive-Waste Management Technology Centre, National Atomic Energy Agency of Indonesia(Indonesia)

    1996-07-01

    Thyroid dose estimation at Radioisotope Production Centre workers using WBC and calculation based on I-131 concentration in working area has been done. The aim of this research is to get the relation between WBC result and calculation using I-131 concentration in working area. The result indicates differences in a range of 3,2% to 53,2%. These differences caused of parameters which influence the calculation are not accurate. These results also indicate that dose estimation using WBC is relatively batter and more accurate but need to have certain information about time of intake.

  6. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO); Programa de verificacion del calculo para un sistema de planificacion de braquiterapia de alta tasa de dosis (PLATO)

    Energy Technology Data Exchange (ETDEWEB)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-07-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  7. Dose on the entrance surface of thyroid, crystalline lens and gonads during the chest X-rays studies; Dosis en la superficie de entrada de tiroides, cristalino y gonadas durante los examenes radiologicos de torax

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez G, R.; Guerra M, J. A.; Pinedo S, A.; Hernandez O, M.; Duran M, H. A.; Salas L, M. A.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico); Rivera M, T. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, IPN, Av. Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolita, Unidad Iztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)], e-mail: rgg_df@hotmail.com

    2009-10-15

    There were a measurement series in General Hospital of Fresnillo in X-rays department in areas of X-1 and X-2 ray rooms and in a neonatal intensive care unit 2, the dose was determined on the entrance surface into eyes, thyroid and gonads for patients undergoing to X-rays study of tele chest by thermoluminescent dosimetry. 5 dosemeters were used in each of the scans, found the following dose ranges 20+{sub -} 23 {mu}Gy to 350 +{sub -} 41 {mu}Gy. With results we can conclude that the used procedures and the calibration equipment are adequate. (Author)

  8. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I; Dosis al personal de hospitalizacion en el tratamiento de pacientes de braquiterapia oftalmica con I-125

    Energy Technology Data Exchange (ETDEWEB)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-07-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  9. Implications of the new dose limit crystalline in operational radiation protection in interventional medicine; Implicaciones del nuevo limite de dosis en cristalino en la proteccion radiologica operacional en intervencionismo

    Energy Technology Data Exchange (ETDEWEB)

    Roch Gonzalez, M.; Garcia Castanon, P.; Giner Sala, M.; Rodriguez Martin, G.; Espana Lopez, M. L.

    2013-07-01

    The objective of this study is to evaluate the implications of this new limit of equivalent dose in the lens can be assumed in the radiation protection of cardiologists, radiologists, nursing professionals, etc. that perform their work in units of intervention, both in terms of additional protective measures and the classification of them as workers exposed. (Author)

  10. Thyroid dose measurement in patients undergoing to digital orthopantomography using optical stimulation dosimeters; Medicion de dosis en tiroides en pacientes sometidos a ortopantografia digital utilizando dosimetros de estimulacion optica

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Calz. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Avalos P, L. Y., E-mail: jggm25@yahoo.com.mx [UNAM, Facultad de Odontologia, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico)

    2016-10-15

    In this paper we present the study of the thyroid equivalent dose in 300 patients undergoing to digital orthopantomography for dental treatment purposes using optical stimulation dosimeters (OSL) as in-vivo dosimeters, in order to verify if this is within acceptable parameters to prevent stochastic risks and to evaluate the possible risks caused by the technique used for this type of study (66 kv, 5 m A, 14.1 s). Three OSL dosimeters were used per patient, which were placed by the physician on the skin above the thyroid gland (using anatomical references and palpation); the information of the patients was divided by neck size and sex, finding a slight increase in the equivalent dose for female and small size patient, this combination being the group that was submitted to a higher dose. The results obtained were compared with similar studies performed on anthropomorphic mannequins with TLD dosimeters obtaining lower results. The equivalent dose found even though is below the threshold stochastic damage must be motorized for radiological protection and registration purposes. (Author)

  11. Nuclear medicine at Camaguey, 1995-1999. Frequency of examinations and collective effective dose to the population; Medicina nuclear en Camaguey, 1995-1999. Frecuencia de examenes y dosis efectiva colectiva a la poblacion

    Energy Technology Data Exchange (ETDEWEB)

    Barreras, C. Aldo; Brigido, F. Osvaldo; Naranjo, L. Angela [Centro de Atencion a la Actividad Nuclear, Camaguey (Cuba)]. E-mail: sean@caonao.cmw.inf.cu; Lasserra, S. Oscar; Hernandez, G. Jose [Hospital Oncologico Maria Curie, Camaguey (Cuba)

    2001-07-01

    A study of the frequency of examinations for diagnosis in the territory of Camaguey-Ciego de Avila, Cuba, was made from the accumulated statistic in the period of 1995-1999 with the objective to obtain data to estimate the collective dose distributed to the population of this territory. It was determined that the annual frequency average of examinations was of 3,82 by each 1000 inhabitants. The obtained data allowed to evaluate the contribution of the different examinations from the collective dose, corresponding to the gamma radiographs of thyroid and pick up 43,73 and 43,36%, respectively, of the 54,43 Sv.man distributed to the population like annual. In this work the annual behavior of the collective dose for the studied period and its behavior in relation to the frequency of made examinations are analyzed. The smaller annual collective dose corresponded to 1996 with 39,05 Sv.man, while the greater value corresponded to 1999 with 66,67 Sv.man. The additional total damage for the studied period is considered: there would be 19,87 additional cases like result of 21073 nuclear medicine examinations, of which 13,6 correspond to mortal cancer. The obtained results are compared with the results reported for other countries.

  12. Temporal evolution of the environmental dose remaining in a clinical irradiation bunker after the cessation of irradiation; Evolucion temporal de la Dosis ambiental remanente en un bunker de irradiacion clinica tras el cese de la irradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Egea, E.; Sanchez Carrascal, M.; Torres Pozas, S.; Monja Ray, P. de la; Perez Molina, J. L.; Madan Rodriguez, C.; Luque Japon, L.; Morera Molina, A.; Hernandez Perez, A.; Barquero Bravo, Y.; Morengo Pedagna, I.; Oliva Gordillo, M. C.; Martin Olivar, R.

    2011-07-01

    In this paper we try to quantify the dose emitted by different radioactive processes that occur in the head of a clinical linear accelerator and the patient is irradiated, or walls of the bunker, converted into tertiary sources of radiation trying to establish the origin of the came in different parts of the bunker.

  13. Evaluation of dose to skin surface contamination in the factory Juzbado of fuel elements; Evaluacion de dosis a piel por contaminacion superficial en la fabrica de elementos combustibles de Juzbado

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Trujillo, D.; Agustin Perez Fonseca, A.; Alejandro Fuentes, A.

    2013-07-01

    The aim of this work is previously set a simple calculation methodology applicable to the boundary conditions surrounding the environment where skin contamination may have occurred so that you can evaluate in a simple and fast way the dose that the worker is receiving while enduring such pollution. (Author)

  14. The ferrous ammonium sulfate solid system, as dosemeter for processes at low temperatures and high doses of gamma radiation; El sistema sulfato ferroso amoniacal solido, como dosimetro para procesos a bajas temperaturas y altas dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Juarez C, J.M.; Ramos B, S.; Negron M, A. [ICN-UNAM, 04510 Mexico D.F. (Mexico)

    2005-07-01

    This paper presents the results obtained from a study of the radiation induced oxidation of crystalline ferrous ammonium sulfate with gamma rays at 295 K, 263 K and 77 K and dose from 0 to 300 kGy. The radiation induced decomposition of ferrous ammonium sulfate has been studied by the dissolution of the irradiated salt in 0,8 N sulfuric acid. The main product is Fe{sup 3+} and molar concentration of ferric ion was determined spectrophotometrically in the UV region at 304 nm. The optical density values showed a linear dependence with dose, indicating that the data obtained might be used to create a calibrating curve. Color in irradiated salt changes from blue to green, yellow and orange according to the absorbed dose. The accuracy and the reproducibility of the system were tested. In addition, some other characteristics make possible the use of this system as a dosimeter, similar to Fricke chemical dosemeter, at low temperatures and high dose. (Author)

  15. Comparative dosimetric study in the estimation of the dose rate of the Transelektro LGI-01 irradiator; Estudio dosimetrico comparativo en la estimacion de la razon de dosis del irradiador Transelektro LGI-01

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco A, H.; Urena N, F.F. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2004-07-01

    The {sup 60} Co TRANSELEKTRO, model LGI-0 1, Hungarian, is similar to the Canadian Gamma cell. The evaluation of the dose ratio in the geometric center of the exposition chamber of the LGI-0 1 is presented in this paper. In order to do this two types of dosimeters were used: the alanine, and the L8-C 1 red acrylic (Canadian). Three dosimeters of each type were irradiated at 1, 2, 3, 4, 5, 6, 7 and 8 h. The respective intensities and absorbencies were measured and used to determine the proper absorbed doses and the dose ratio. The results obtained with both dosimeters were compared with the ratio dose that was reported by the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of the ININ, which used a ionization chamber for the calibration of the LGI-0 1. The alanine dosemeter showed a {+-} 1.3% dispersion while with the acrylic dosemeter the dispersion was of {+-} 3.2%, with respect to the value reported by the authorized Calibration Laboratory. This paper was also used to update the calibration table of the L8-C1 red acrylic. (Author)

  16. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements; Determinacion del coeficiente de conversion para la dosis equivalente ambiental, H*(10), a partir de mediciones de kerma en aire

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, F. [UNAM, Facultad de Ciencias, Circuito Exterior, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D{sub PMMA}(10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K{sub a} obtaining a value of 1.20 Sv Gy{sup -1} with a u{sub c}= 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy{sup -1} with a u{sub c}= 2%. (Author)

  17. On the implementation of new versions of the algorithms of calculation of dose absorbed in radiotherapy external; Sobre la implementacion de nuevas versiones de los algoritmos de calculo de dosis absorbida en radioterapia externa

    Energy Technology Data Exchange (ETDEWEB)

    Latorre-Musoll, A.; Carrasco de Fez, P.; Lizondo Gisbert, M.; Jordi-Ollero, O.; Jornet Sala, N.; Eudaldo Puell, T.; Ruiz Martinez, A.; Ribas Morales, M.

    2015-07-01

    The changes of version of the algorithms of calculation of dose absorbed in radiotherapy external should implement in a time reduced due to the pressure care. A set reduced of checks could pass by high discrepancies significant between the stones and the measures experimental, as illustrate in this work. (Author)

  18. Use of Monte Carlo simulation software for the calculation of the effective dose in cone beam Tomography; Uso del software de simulacion Monte Carlo para el calculo de la dosis efectiva en Tomografia de haz conico

    Energy Technology Data Exchange (ETDEWEB)

    Gomes B, W. O., E-mail: wilsonottobatista@gmail.com [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Bardalho, 40301-015 Salvador, Bahia (Brazil)

    2015-10-15

    Full text: In this study irradiation geometry applicable to PCXMC and the consequent calculation of effective dose in applications of cone beam computed tomography (CBCT) was developed. Two different CBCT equipment s for dental applications were evaluated: Care Stream Cs-9000 3-Dimensional and Gendex GXCB-500 tomographs. Each protocol initially was characterized by measuring the surface kerma input and the product air kerma-area, P{sub KA}. Then, technical parameters of each of the predetermined protocols and geometric conditions in the PCXMC software were introduced to obtain the values of effective dose. The calculated effective dose is within the range of 9.0 to 15.7 μSv for Cs 9000 3-D and in the range 44.5 to 89 mSv for GXCB-500 equipment. These values were compared with dosimetric results obtained using thermoluminescent dosimeters implanted in anthropomorphic mannequin and were considered consistent. The effective dose results are very sensitive to the radiation geometry (beam position); this represents a factor of fragility software usage, but on the other hand, turns out to be a very useful tool for quick conclusions regarding the optimization process of protocols. We can conclude that the use of Monte Carlo simulation software PCXMC is useful in the evaluation of test protocols of CBCT in dental applications. (Author)

  19. System of data management in 'Dosis' personal dosimetry

    International Nuclear Information System (INIS)

    Manzano de Armas, Jose; Diaz Bernal, Efren; Capote Ferrera, Eduardo; Molina Perez, Daniel; Lopez Bejerano, Gladys

    2001-01-01

    The storage and control of the data of a service of personal dosimetry is a task that requires specify care in data handling and manipulation. This activity becomes more annoying of making manually when the volume of users of the service is significant. The External Dosimetric Laboratory of the Center for Radiation Protection and Hygiene has developed a system of administration of data that allows the storage, control and analysis of the data generated by the Service of Personal Dosimetry in an efficient and reliable way. This paper describes the characteristics of the System for Administration of Data in Personal Dosimetry 'Dosis', as well as their design and programming. The importance of this System for the laboratory and the advantages of their application are described. The characteristics of the different modules are also described. (author)

  20. Study of the radiation levels in low dose rate brachytherapy zones of the National Institute of Neoplastic Illnesses; Estudio de los Niveles de Radiacion en Zonas de Braquiterapia de Baja Tasa de Dosis del Instituto Nacional de Enfermedades Neoplasicas

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa J, N.; Mora Y, B. [Instituto Nacional de Enfermedades Neoplasicas, Lima (Peru)]. e-mail: navorf01@yahoo.es

    2006-07-01

    The present study has as objective to evaluate the radiation levels of the Brachytherapy work areas of low dose rate (Gammateque, nurses station and of hospitalization rooms of patients RIC of 4th, 5th Floor-East) and to estimate the effective dose of the occupationally exposed personnel and the public in general. The measurements of the dose rate in these areas, were registered with a radiations monitor Inspector trademark, during a period of 60 days, without altering the routinary work conditions. The more high levels of environmental dose equivalent rate registered in the different work areas its are of 1.41 and 47.78 {mu}Sv/h rooms 1 and 2 in the Gammateque environments, in the hospitalization rooms of the 4th and 5th floor in the point 1 are of 40.77 and 23.67, {mu}Sv/h respectively and in the point 2 are of 129.19 and 39.93, {mu}Sv/h respectively, and in the nurses station of the 4th and 5th floor its are respectively of 7.62 u Sv/h and 0.45 u Sv/h. According to the carried out measurements and the permanency in the work place is possible to estimate the effective dose involved to the occupationally exposed personnel. The personnel that works in Gammateque could be receiving respectively as maximum dose 0.61 mSv/month, and the personnel that works in the nurses station of 13.17 and 0.78 mSv/year in the 4th and 5th floor. These registered differences among the two floors are due to that the 5th floor counts with the shielding systems (screen) contrary to the 4th, another of the factors is the distribution form of the patient beds RIC. We should have present that the radiation levels although in some cases it is very high, however, they are below of the permissible limits according to standards, but it is still possible to reduce even more, the radiation levels in the critical points fulfilling with the ALARA principle. (Author)

  1. Vivax malaria in children: recurrences with standard total dose of primaquine administered in 3 vs. 7 days Malaria vivax en niños: recurrencias con dosis total estándar de primaquina administrada durante 3 frente a 7 días

    Directory of Open Access Journals (Sweden)

    Jaime Carmona-Fonseca

    2010-02-01

    Full Text Available

    Introduction: Worldwide, the efficacy of cloroquine-primaquine for treating acute Plasmodium vivax malarious attacks has not been thoroughly evaluated. In Latin America such studies are scarce, and in Colombia, almost nonexisting.

    Objective: To assess the efficacy of two regimens for administration of primaquine in children aged less than 18 years.

    Methodology: A clinical, controlled, unmasked study was carried out, with randomized administration of two primaquine regimens, namely: 0.50 mg/kg/day for 7 days (0.50-7 vs. 1.17 mg/kg/day for 3 days (1.17-3.

  2. EPR response of sucrose and microcrystalline cellulose to measure high doses of gamma radiation; Respuesta EPR de sacarosa y celulosa micro cristalina para medir altas dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Torijano, E.; Cruz, L.; Gutierrez, G.; Azorin, J.; Aguirre, F. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Cruz Z, E., E-mail: eftc@xanum.uam.mx [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2015-10-15

    Solid dosimeters of sucrose and microcrystalline cellulose (Avicel Ph-102) were prepared, following the same process, in order to compare their EPR response against that of the l-alanine dosimeters considered as reference. All lots of dosimeters were irradiated with gamma radiation in Gamma beam irradiator with 8 kGy/h of the Nuclear Sciences Institute of UNAM. Doses ranged from 1 to 10 kGy respectively. We found that both the response of sucrose as microcrystalline cellulose were linear; however, the response intensity was, on average, twenty times more for sucrose. Comparing this against the EPR response of l-alanine in the range of doses, it was found that the response to sucrose is a third part; and microcrystalline cellulose is a sixtieth, approximately. The results agree with those found in the literature for sucrose, leaving open the possibility of investigating other dosage ranges for cellulose. (Author)

  3. Gamma knife radio-surgery in meningiomas: decisive variables in the dose prescription during 14 years; Radiocirugia gamma knife en meningiomas: variables determinantes en la prescripcion de dosis durante 14 anos

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez O, X.; Diaz A, P.; Toledo B, V.; Zazueta L, F., E-mail: pdiaz@hospitalsanjavier.co [Hospital San Javier, Pablo Casals No. 640, Col. Prados Providencia, 44670 Guadalajara, Jalisco (Mexico)

    2010-09-15

    A comparative study is presented among the variables of dose prescription in twelve cases of treated meningiomas from 1997 to 2009 in the Gamma Knife Unit of the Hospital San Javier. An evolution is observed in the definition of the treatment volumes, collimators election and matrix of dose calculation, this evolution has been due so much to the technological advance associated to the image acquisition systems: Computerized axial tomography, Images by magnetic resonance and Angiography by digital subtraction, as well as to the indexes adoption that are used to qualify among different treatment plans. The differences among the analyzed periods demonstrate a favorable learning curve that have influenced contributing to a treatment with a minor irradiated volume due to the application of theoretical models used in this installation, attenuating the risk of peripheral unexpected complications to the treated volume. (Author)

  4. Didactic revision of the operative magnitudes system ICRU for the evaluation of the equivalent dose in radiation external fields; Revision didactica del sistema de magnitudes operativas ICRU para la evaluacion de la dosis equivalente en campos externos de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    In this work is presented in a didactic way the operative magnitudes system ICRU, showing as these magnitudes carry out an appropriate estimate of the effective equivalent doses H{sub E} and the effective dose. The objective is to present the basic concepts of the dosimetry for radiation external fields with purposes of radiological protection, because the assimilation lack and technological development of this dosimetric magnitudes system has persisted for near 50 years, in terms of practice of the radiological protection in Mexico. Also, this system is an essential part of safety basic standards of the IAEA and ICRP recommendations 26, 60, 74 and 103, as well as of the ICRU 25, 39, 43, 51 and 57. (Author)

  5. Uncertainties in the correction factors as the dose polarization and recombination at different energies; Incertidumbres en la medida de factores de correccion a la dosis por polarizacion y recombinacion a diferentes energias

    Energy Technology Data Exchange (ETDEWEB)

    Alejo Luque, L.; Rodriguez Romero, R.; Castro Tejero, P.; Fandino Lareo, J. M.

    2011-07-01

    This paper discusses the measures and uncertainties of the correction factors for dose-polarization (k, 1) and recombination (k,) of different ionization chambers plane-parallel and cylindrical. The values ??have been obtained using photon and electron beams of various energies generated by linear accelerators nominal Varian 21EX CLJNAC Tomotherapy Hi-Art and JI. We study the cases in which you can avoid the application of the factors obtained, according to the criteria proposed.

  6. Doses produced in Spain as a results of radiation-based diagnosis (Projects Dopoes{sub D}omnes); Dosis producidas en Espana como consecuencia del diagnostico con radiaciones (Proyectos Dopoes{sub D}omnes)

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Cruces, R.; Ramirez Vera, M. L.; Alvarez Garcia, C.; Ferrer, N.

    2016-08-01

    The number of medical examinations and procedures that use ionizing radiation have continuously increased in recently years. More than 90% of human-generated exposures to ionizing radiation are from medical uses and the collective dose due to patient exposures is 200 times greater than the occupational dose of exposed workers. At the same time, the emergence of new technologies, the increased use of Computerized Tomography (CT)-even for pediatric patients- the development of digital radiography, interventional radiology and the new technologies in nuclear medicine with the use of hybrid PET/CT and SPECT/CT equipment have all contributed as well to an increase in the doses received by patients. This poses a challenge to the regulatory authorities in the field of radiological protection, the goal of which is to makes sure that the risks to patients are as low as possible compared to the benefits yielded by the use of ionizing radiation for medical purposes, in accordance with ALARA criteria. (Author)

  7. Measurement of the relationship of {sup 24} Na activity and the received neutron dose; Medicion de la relacion de la actividad de {sup 24}Na y la dosis de neutrones recibida

    Energy Technology Data Exchange (ETDEWEB)

    Gossio, S.; Carrelli, J.; Villella, A.; Soppe, E., E-mail: sgossio@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    In cases of criticality accidents it is required a fast dosimetric system that allows to evaluate the doses of the personnel involved. The reaction (n,y) with sodium presented in the body ({sup 23}Na), generates {sup 24}Na, that emits two gamma of 1369KeV and 2754 KeV that can be measured using a whole body counter. The experienced were carried out with the irradiation of {sup 252} Cf of a phantom with a solution of NaCl in water. After the irradiation it was measured the {sup 24}Na activity in the whole body counter, which has a HPGe detector previously calibrated in energy and efficiency. Considering the correction by decay, the quantity of {sup 23}Na presented in the body of an adult and elimination curve of {sup 24}Na, it was established a coefficient of neutronic doses by unity of activity of {sup 24}Na measured in the whole body counter. This method is useful for the retrospective estimation of the doses, as well as to carry out a radiological sorting in case of criticality.

  8. Neutron spectra calculation and doses in a subcritical nuclear reactor based on thorium; Calculo de espectros de neutrones y dosis en un reactor nuclear subcritico a base de Torio

    Energy Technology Data Exchange (ETDEWEB)

    Medina C, D.; Hernandez A, P. L.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Sajo B, L., E-mail: dmedina_c@hotmail.com [Universidad Simon Bolivar, Laboratorio de Fisica Nuclear, Apdo. Postal 89000, Caracas 1080A (Venezuela, Bolivarian Republic of)

    2015-10-15

    This paper describes a heterogeneous subcritical nuclear reactor with molten salts based on thorium, with graphite moderator and a source of {sup 252}Cf, whose dose levels in the periphery allows its use in teaching and research activities. The design was done by the Monte Carlo method with the code MCNP5 where the geometry, dimensions and fuel was varied in order to obtain the best design. The result is a cubic reactor of 110 cm side with graphite moderator and reflector. In the central part they have 9 ducts that were placed in the direction of axis Y. The central duct contains the source of {sup 252}Cf, of 8 other ducts, are two irradiation ducts and the other six contain a molten salt ({sup 7}LiF - BeF{sub 2} - ThF{sub 4} - UF{sub 4}) as fuel. For design the k{sub eff}, neutron spectra and ambient dose equivalent was calculated. In the first instance the above calculation for a virgin fuel was called case 1, then a percentage of {sup 233}U was used and the percentage of Th was decreased and was called case 2. This with the purpose to compare two different fuels working inside the reactor. In the case 1 a value was obtained for the k{sub eff} of 0.13 and case 2 of 0.28, maintaining the subcriticality in both cases. In the dose levels the higher value is in case 2 in the axis Y with a value of 3.31 e-3 ±1.6% p Sv/Q this value is reported in for one. With this we can calculate the exposure time of personnel working in the reactor. (Author)

  9. Concentration of {sup 222}Rn in drinking water of the Zacatecas City, measured by liquid scintillation and associated dose; Concentracion de {sup 222}Rn en agua potable de la Ciudad de Zacatecas, medida por centelleo liquido y dosis asociada

    Energy Technology Data Exchange (ETDEWEB)

    Arevalo B, C. A.; Lopez del R, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.; Rios M, C.; Saucedo A, S. A., E-mail: cesar_arevalob@outlook.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2017-09-15

    A study was carried out to determine the concentration of {sup 222}Rn in samples of drinking water collected from different homes in the Zacatecas city, Mexico, whose main source of supply is groundwater. The {sup 222}Rn radioactive gas is a product of the decay series of {sup 238}U and is considered one of the main sources of natural radiation, since it contributes almost half of the radiation dose that a person will receive throughout his life. The {sup 222}Rn originates in the rocks of the aquifers and dissolves in the water, which is later integrated into the distribution network of the public supply that supplies the entire population. Exposure to ionizing radiation that {sup 222}Rn and its offspring emit can damage the DNA molecule, inducing the possible appearance of cancer. Has been demonstrated by various epidemiological studies carried out in uranium mines workers in different parts of the world, that this exposure increases the incidence of lung cancer, placing {sup 222}Rn and their offspring as the second main cause of this type of cancer, after smoking habit. Using the technique of solvent extraction of {sup 222}Rn in water and liquid scintillation spectrometry, water collected from 14 different households was sampled and analyzed. The average of the measured activity of {sup 222}Rn was 2.09 Bq/L and the annual effective dose per water intake attributable to that concentration of 6.07 mSv/a. The concentration of {sup 222}Rn in water and the annual effective dose are below 11 Bq/L and 50 mSv/a, such concentrations are the maximum limits established by the Unites States Environmental Protection Agency (US EPA) and the ICRP, respectively. The concentration of {sup 222}Rn that is transferred from the water to the air inside a house was also calculated and the radiation dose that this concentration causes by inhalation, being 0.209 Bq/m{sup 3} and 1,463 μ Sv a, respectively. (Author)

  10. PENGARUH PEMBERIAN BERBAGAI DOSIS MIKORIZA PADA KOMPOS SAMPAH KOTA TERHADAP PERTUMBUHAN DAN HASIL TANAMAN KEDELAI (Glycine max (L.) Merril) DALAM KEADAAN CEKAMAN AIR (Mycorrhizal Doses Effect of Various Cities Compost Trash on Plant Growth and Yields of S

    OpenAIRE

    Afriyon, Rendra; Soverda, Nerty; Myrna, Nyimas

    2014-01-01

    The study was conducted in order to see the effect of mycorrhiza on municipal solid waste compost on the growth and yield of soybean under water stress conditions. The research also aims to obtain doses of mycorrhiza plus municipal waste compost is best for the growth and yield of soybean in the state of water stress. The study was conducted using a completely randomized design (CRD) is a factor, giving Mycorrhizae. Media used in all treatments and so on municipal solid waste compost added 20...

  11. Spectra and absorbed dose by photo-neutrons in a solid water mannequin exposed to a Linac of 15 MV; Espectros y dosis absorbida por fotoneutrones en un maniqui de agua solida expuesta a una Linac de 15 MV

    Energy Technology Data Exchange (ETDEWEB)

    Benites R, J. [Centro Estatal de Cancerologia de Nayarit, Servicio de Seguridad Radiologica, Calz. de la Cruz 118 Sur, 63000 Tepic, Nayarit (Mexico); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Apdo. Postal 336, 98000 Zacatecas (Mexico); Velazquez F, J., E-mail: jlbenitesr@prodigy.net.mx [Universidad Autonoma de Nayarit, Posgrado en Ciencias Biologico Agropecuarias, Carretera Tepic-Compostela Km 9, 63780 Jalisco-Nayarit (Mexico)

    2012-10-15

    Using Monte Carlo methods was modeled a solid water mannequin; according to the ICRU 44 (1989), Tissue substitutes in radiation dosimetry and measurements, of the International Commission on Radiation Units and Measurements; Report 44. This material Wt 1 is made of H (8.1%), C (67.2%), N (2.4%), O (19.9%), Cl (0.1%), Ca (2.3%) and its density is of 1.02 gr/cm{sup 3}. The mannequin was put instead of the patient, inside the treatment room and the spectra and absorbed dose were determined by photo-neutrons exposed to a Linac of 15 MV. (Author)

  12. Thermal annealing of high dose radiation induced damage at room temperature in alkaline. Stored energy, thermoluminescence and coloration; Aniquilacion termica de dano inducido por irradiacion a altas dosis en haluros alcalinos a 300 k. energia almacenda. Termoluminiscencia y coloracion

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, L

    1980-07-01

    The possible relation between stored energy, thermoluminescence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminescence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KC1 samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose.Capacity of alkali halides to store energy by irradiation increases as the cation size decreases. (Author) 51 refs.

  13. 131I intake survey and effective dose calculation for personnel in a nuclear medicine department; Vigilancia de incorporaciones de 131I y estimacion de dosis efectiva comprometida en el personal de un servicio de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Laguna, A.; Estrada-Lobato, E.; Brandan, M.E.; Medina, L.A.

    2010-07-01

    The staff of a nuclear medicine department is subject to the risk of 131I intake as consequence of oversights in the radiation safety procedures, the occurrence of an accident, or malicious acts. The intake can be estimated by using a detection system based on NaI(Tl) or HpGe. This paper presents a methodological proposal for the use of a gammacamera for detection of occupational intakes of 131I in the Nuclear Medicine staff. We used a Siemens e.cam gamma camera (GC) as the radionuclide intake detection system. GC sensitivity and minimum detectable activity were determined to quantify activity retained in the thyroid gland. A whole-body anthropomorphic phantom REMCAL was also used to simulate and quantify the intake in the thyroid gland. To estimate the minimal uptake and the minimal committed effective dose E(50) that can be quantified with the gammacamera, the AIDE (Activity and Internal Dose Estimates) software was used. The gammacamera can detect 131I activity in thyroid, as low as 175 Bq without collimators, and 5948 Bq with high-energy collimators. The calculation of E(50) shows to be as low as 5% of the annual limit. This work has shown the utility of the gammacamera to detect intakes of 131I and to estimate the E(50). (Author).

  14. Dosimetric implications associated to heterogeneity dose correction in stereotactic body radiation therapy (SBRT) of lung cancer; Implicaciones dosimetricas asociadas al calculo de dosis con correccion de heterogeneidad en radioterapia estereotaxica extracraneal (SBRT) de pulmon

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrila

    2016-10-01

    Treatment of lung lesions using stereotactic body radiation therapy (SBRT) requires algorithms with corrections that adequately model the behavior of narrow beams in the presence of tissue heterogeneities, although protocols such as RTOG 0236 excluded these kind of corrections. 100 cases were evaluated retrospectively following the RTOG 0813 and RTOG 0915 guidelines, by obtaining the deviations of the relevant dosimetric indicators from Monte Carlo (MC) and Pencil Beam (PB), maintaining the same configuration and monitor units (MU). Deviations between MC and PB have been classified according to the volume and density of the lesion. The greatest variations (up to 45% difference in D50%) are found for cases with lower volume and density, where the lesion is almost equivalent to lung tissue, given the higher proportion of air surrounding the periphery of the tumor, and the reduction of the radiation fields, resulting in a lack of electronic equilibrium that must be properly considered in the treatment planning system. These deviations involve dosimetric implications which are observable in clinical outcomes, determining how to proceed in treatment planning, to ensure that the actual dose delivered is performed accordingly to the prescription dose, while requiring the use of algorithms with a proper heterogeneity correction. (Author)

  15. Evaluation of dose due to the liberation of the radioactive content present in systems of final disposal of radioactive residues; Evaluacion de la dosis debida a la liberacion del contenido radiactivo presente en sistemas de disposicion final de residuos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Amado, V; Lopez, F [Autoridad Regulatoria Nuclear, Av. Del Libertador 8250, Ciudad Autonoma de Buenos Aires (C1429BNP) (Argentina)

    2006-07-01

    The disposal systems of radioactive residuals well-known as repositories near to the surface, are used to dispose residuals that can contain high concentrations of radionuclides of period of short semi disintegration, which they would decay at levels radiologically insignificant in some few decades or in some centuries: and acceptably low concentrations of radionuclides of period of long semi disintegration. The dose that would receive the critic group due to these systems it could be increased by cause of discreet events that affect the foreseen retard time, or by the gradual degradation of the barriers. To this last case it contributes the presence of water, because it implies leaching and dissolution that can give place to radionuclide concentrations in the underground water greater to the prospective ones. The dosimetric evaluation is important because it offers useful objective information to decide if a given repository is adjusted to the purposes of its design and it fulfills the regulatory requirements. In this work a simplified evaluation of the dose that would receive the critic group due to the liberation of contained radionuclides in a hypothetical system of final disposition of radioactive residuals is presented. For it, they are considered representative values of the usually contained activities in this type of systems and they are carried out some approaches of the source term. The study is developed in two stages. In the first one, by means of the Radionuclide pollutant scattering pattern in phreatic aquifers (DRAF) it is considered the scattering of the pollutants in the phreatic aquifer, until the discharge point in the course of the nearest surface water. This model, developed originally in the regulatory branch of the National Commission of Argentine Atomic Energy (CNEA); it solves the transport equation of solutes in porous means in three dimensions, by the finite differences method having in account the soil retention and the radioactive

  16. Estimated doses related to {sup 222}Rn concentration in bunker for radiotherapy and storage of radioisotopes; Dosis estimada por concentraciones de {sup 222}Rn en bunker de radioterapia y de almacenamiento de isotopos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, Freddy; Carrizales-Silva, Lila, E-mail: freddymest@gmail.com, E-mail: lcarriza@ivic.gob.ve [Instituto Venezolano de lnvestigaciones Cientificas, Caracas (Venezuela, Bolivarian Republic of); Sajo-Bohus, Laszlo, E-mail: sajobohus@gmail.com [Universidad Simon Bolivar, Caracas (Venezuela, Bolivarian Republic of). Laboratorio de Fisica Nuclear; Diaz, Cruz, E-mail: cruzediaZ@gmail.com [Universidad Pedagogica Experimental Libertador, Barquisimeto (Venezuela, Bolivarian Republic of). Instituto Pedagogico

    2013-07-01

    It was done a survey in radiotherapy services underground hospitals and clinics of Venezuela and Paraguay in order to estimate the concentrations of radon and its possible consequences on worker occupational exposure. Passive dosimeters were used to assess nuclear traces (NTD type CR-39 Registered-Sign ). The concentration of {sup 222}Rn is determined based on the density of traces using the calibration coefficient of 1 tr/cm{sup 2} equivalent to 0,434 Bqm{sup -3} per month of exposure. Assuming the most likely environmental conditions and the dose conversion factor equal to 9.0 x 10{sup -6} mSv h {sup -1} by Bqm{sup -3}, it was determined the average values and estimated the possible risks to health that are on average 3.0 mSva{sup -1} and 150 micro risk cancer.

  17. Study of the heterogeneities effect in the dose distributions of Leksell Gamma Knife (R), through Monte Carlo simulation; Estudio del efecto de las heterogeneidades en las distribuciones de dosis del Leksell GammaKnife (R), mediante simulacion Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Al-Dweri, F.M.O.; Lallena R, A.M. [Universidad de Granada, Granada (Spain)]. e-mail: elrc@nuclear.inin.mx

    2005-07-01

    In this work they are studied, by means of Monte Carlo simulation, the effects that take place in the dose profiles that are obtained with the Leksell Gamma Knife (R), when they are kept in account heterogeneities. The considered heterogeneities simulate the skull and the spaces of air that are in the head, like they can be the nasal breasts or the auditory conduits. The calculations were made using the Monte Carlo Penelope simulation code (v. 2003). The geometry of each one of the 201 sources that this instrument is composed, as well as of the corresponding channels of collimation of the Gamma Knife (R), it was described by means of a simplified model of geometry that has been recently studied. The obtained results when they are kept in mind the heterogeneities they present non worthless differences regarding those obtained when those are not considered. These differences are maximum in the proximities of the interfaces among different materials. (Author)

  18. Toxicidad de VA-DIFTET® por administración a dosis repetida en ratones

    Directory of Open Access Journals (Sweden)

    Pablo González

    2000-06-01

    Full Text Available Una vez estudiada la toxicidad de la vacuna VA-DIFTET® (vacuna antidiftérica antitetánica por administración a dosis única en dos especies de animales, se impone la evaluación a dosis repetida, teniendo en cuenta que el esquema de inmunización en humanos prevé la aplicación de tres dosis cuando el componente pertusis de la DPT está contraindicado. Se emplearon 210 ratones OF-1 de ambos sexos. Los grupos experimentales fueron similares a los de la prueba a dosis única con la vacuna dúplex, anatoxina diftérica, anatoxina tetánica, adyuvante, tiomersal, solución salina fisiológica y un grupo control no tratado. Un grupo de hembras y otro de machos fue asignado aleatoriamente a cada tratamiento y para recibir 1, 2 ó 3 dosis por vía intramuscular. Tras cada aplicación se evaluó la aparición de síntomas clínicos, el incremento de peso, el consumo de agua y alimento y la dinámica de la respuesta inmune contra las anatoxinas tetánica y diftérica, específicamente de tipo IgG, mediante ELISA indirecto. Al término de las observaciones los animales fueron sacrificados y se realizaron estudios anatomopatológicos. Además, durante el sacrificio se evaluó el índice relativo de bazo y timo, así como la relación bazo/timo. No se comprobaron alteraciones que evidenciaran toxicidad por parte de la vacuna y sus componentes. Asimismo, se demostró una marcada respuesta inmune en los grupos vacunales e inoculados con las anatoxinas. Se considera que los resultados de la prueba fueron satisfactorios.

  19. Raquianestesia unilateral com baixa dose de bupivacaína a 0,5% hiperbárica Raquianestesia unilateral con baja dosis de bupivacaína a 0,5% hiperbárica Unilateral spinal anesthesia with low 0.5% hyperbaric bupivacaine dose

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Imbelloni

    2004-10-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A raquianestesia unilateral pode apresentar vantagens, principalmente em pacientes ambulatoriais. Baixas doses da solução anestésica, agulhas ponta de lápis ou ponta cortante, lenta velocidade de injeção e a posição lateral têm sido relatados como facilitadores da produção de raquianestesia unilateral. O presente estudo longitudinal investiga o grau de raquianestesia unilateral utilizando 5 mg de bupivacaína a 0,5% hiperbárica injetada através de agulha 27G tipo Quincke no paciente em decúbito lateral, com membro a ser operado voltado para baixo. MÉTODO: Raquianestesia com bupivacaína a 0,5% foi realizada através da agulha 27G Quincke em 30 pacientes estado físico ASA I e II, submetidos à cirurgias ortopédicas. A punção subaracnóidea foi realizada com o paciente previamente colocado com o lado a ser operado voltado para baixo e foram injetados 5 mg de bupivacaína a 0,5% hiperbárica na velocidade de 1 ml.15s-1. Bloqueios sensitivo e motor (picada de agulha e escala de 0 a 3 foram comparados entre os lados a ser operado e o contralateral. RESULTADOS: Os bloqueios motor e sensitivo entre o lado operado e o contralateral foram significativamente diferentes em todos os momentos. Raquianestesia unilateral foi obtida em 85,7% dos pacientes. Estabilidade hemodinâmica foi observada em todos os pacientes. Nenhum paciente desenvolveu cefaléia pós-raquianestesia. CONCLUSÕES: Nas condições deste estudo a bupivacaína hiperbárica a 0,5% (5 mg proporcionou um predominante bloqueio unilateral. Vinte minutos foram suficientes para a instalação do bloqueio. As principais vantagens da raquianestesia unilateral são a estabilidade hemodinâmica, a satisfação do paciente e recuperação mais rápida da anestesia.JUSTIFICATIVA Y OBJETIVOS: La raquianestesia unilateral pode presentar ventajas, principalmente en pacientes ambulatoriales. Bajas dosis de la solución anestésica, agujas punta de lápiz o

  20. Spectra and neutron dose of an 18 MV Linac using two geometric models of the head; Espectros y dosis por neutrones de un Linac de 18 MV usando dos modelos geometricos del cabezal

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, M. T.; Pino, F.; Barros, H.; Sajo-Bohus, L. [Universidad Simon Bolivar, Laboratorio de Fisica Nuclear, Sartenejas, Baruta 1080-A, Caracas (Venezuela, Bolivarian Republic of); Davila, J. [Fisica Medica C. A., Av. Francisco de Miranda s/n, Los Palos Grandes, 1060 Miranda (Venezuela, Bolivarian Republic of); Salcedo, E. [Centro Medico Docente La Trinidad, Av. de El Haltillo, Caracas (Venezuela, Bolivarian Republic of); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Benites R, J. L., E-mail: mariate9590@gmail.com [Centro de Cancerologia de Nayarit, Servicio de Seguridad Radiologica, Calz. de la Cruz 118 Sur, 63000 Tepic, Nayarit (Mexico)

    2015-10-15

    Full text: Using the Monte Carlo method, by MCNP5 code, simulations were performed with different source terms and 2 geometric models of the head to obtain spectra in energy, flow and doses of photo-neutrons at different positions on the stretcher and in the radiotherapy room. The simplest model was a spherical shell of tungsten; the second was the complete model of a heterogeneous head of an accelerator Varian ix. In both models Tosi function was used as a source term. In addition, for the second model Sheikh-Bagheri distribution was used for photons and photo-neutrons were generated. Also in both models the radiotherapy room of Gurve group of the Teaching Medical Center La Trinidad was included, which is equipped with an accelerator Varian Clinic 2100. In this Center passive detectors PADC (Cr-39) were irradiated with neutron converters, with 18 MeV photons radiation. The measured neutron flow was compared with that obtained with Monte Carlo calculations. The Monte Carlo flows are similar to those measured at the isocenter. The simplest model underestimates the neutron flow compared with the calculated flows with the heterogeneous model of the head. (Author)

  1. Evaluation of the influence of parameters that determine the mean glandular dose in mammography using different detectors; Evaluacion de la influencia de los parametros que determinan la dosis glandular media en Mamografia utilizando diferentes detectores

    Energy Technology Data Exchange (ETDEWEB)

    Costa, K.; Nogueira, M. S., E-mail: katicostabh@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear, Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: Mammography is a test used for early detection of breast cancer. The mean glandular dose (MGD) is dosimetric greatness accepted as indicative of carcinogenic risk induced by ionizing radiation in the breasts of women undergoing mammography exams. MGD value is estimated from the incident air kerma (k i), associated with conversion factors which depend on the half-value layer (HVL), the breast composition and thickness compressed breast. This study aims to evaluate the influence of the parameters used to determine the MGD using different measurement detectors. Measurements were performed on a Siemens Mammomat Model 300 Nova mammography equipment; this has the combinations Anode/Filter of Mo/Mo, Mo/Rh and W/Rh. Detectors used were the ionization chamber Model 10X6-6M manufactured by Radcal Co., two solid-state detectors, one Model AGMS-M manufactured by Radcal Co. and other Model Xi Mammo manufactured by UNFORS. The detectors measures were compared and the MGD value was estimated; differences between measurements and the reference values were higher in HVL and k i parameters. The results are displayed according to other published works. (Author)

  2. Determination of absorbed dose in crystalline and thyroid gland with irradiation protocols applied in orthopantomography equipment for dental examination; Determinacion de dosis absorbida en cristalino y glandula tiroides con protocolos de irradiacion aplicados en equipos de ortopantomografia para panoramica dental

    Energy Technology Data Exchange (ETDEWEB)

    Munoz A, A. A.; Ramirez A, L. M. [Instituto Tecnologico Metropolitano, Grupo de Investigacion e Innovacion Biomedica, Medellin, Antioquia (Colombia); Sosa A, M. A.; Azorin V, J. C.; Vallejo H, M. A. [Universidad de Guanajuato, Departamento de Fisica, Loma del Bosque 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico)

    2016-10-15

    Ionizing radiations are very useful in the medical field for the diagnostic use of different pathologies. Currently there are different technologies for diagnostic imaging using conventional X-ray, computed tomography, mammography, angiography, dental panoramic X-ray, among others. However, it should be noted that exposure to radiation in this type of diagnostic tests has increased considerably in recent years, because radiological examinations are not always carried out according to the actual clinical needs of each patient, increasing the risk to develop cancer. In this paper, the absorbed dose in the lens and thyroid gland was measured with the help of TLD-100 dosimeters located in a PMMA phantom adapted for orthopantomography (dental panoramic X-ray) equipment in 5 hospitals; using the parameters pre-configured for normal adult for irradiation. A Harshaw 3500 equipment was used to read the dosimeters, obtaining a value of 1.324 ± Sd 0.01 mGy for crystalline and 1.044 ± Sd 0.03 mGy values which are intended to be validated under other conditions and protocols. (Author)

  3. Monte Carlo design of a system for the detection of explosive materials and analysis of the dose; Diseno Monte Carlo de un sistema para la deteccion de materiales explosivos y analisis de la dosis

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez A, P. L.; Medina C, D.; Rodriguez I, J. L.; Salas L, M. A.; Vega C, H. R., E-mail: pabloyae_2@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-10-15

    The problems associated with insecurity and terrorism have forced to designing systems for detecting nuclear materials, drugs and explosives that are installed on roads, ports and airports. Organic materials are composed of C, H, O and N; similarly the explosive materials are manufactured which can be distinguished by the concentration of these elements. Its elemental composition, particularly the concentration of hydrogen and oxygen, allow distinguish them from other organic substances. When these materials are irradiated with neutrons nuclear reactions (n, γ) are produced, where the emitted photons are ready gamma rays whose energy is characteristic of each element and its abundance allows estimating their concentration. The aim of this study was designed using Monte Carlo methods a system with neutron source, gamma rays detector and moderator able to distinguish the presence of Rdx and urea. In design were used as moderators: paraffin, light water, polyethylene and graphite; as detectors were used HPGe and the NaI(Tl). The design that showed the best performance was the moderator of light water and HPGe, with a source of {sup 241}AmBe. For this design, the values of ambient dose equivalent around the system were calculated. (Author)

  4. HUBUNGAN DOSIS TEPUNG GEMBILI (Dioscorea esculenta DENGAN TINGKAT EKSPRESI ENZIM Ampk-α2 PADA MODEL TIKUS DIABETES MELITUS

    Directory of Open Access Journals (Sweden)

    neni oktiyani

    2015-06-01

    Full Text Available Abstract: Alternative methods of controlling glucose levels in patients with diabetes is by type of food, either by utilizing yam flour. At the flour contained inulin and resistant starch that can activate the enzyme AMPK-α2. Activation of these enzymes will stimulate glucose transport in skeletal muscle and liver, thus causing a decrease in glucose production. Varying doses of flour is expected to affect the expression of AMPK-α2. This study aims to dosage relationship yam flour (Dioscorea esculenta with tigkat-α2 AMPK enzyme expression in the nucleus skeletal muscle and liver in mouse models of diabetes mellitus. The study was a quasi-experimental design with Post Test Only Group Design. Rats were divided into 5 (five groups, healthy mice, the mice with type 2 diabetes, and type 2 groups of diabetic rats with dietary intake yam flour addition of 1.25 g (TG-1:25,, 2.5 g (TG -2.5, 5.0 g (TG-5.0. Yam flour is mixed into the rat diet feed with varying doses. The results showed no significant correlation between the dose of yam flour with AMPK-α2 expression levels in skeletal muscle nuclei (p = 0.312 and liver (p = 0.474 in a mouse model of DM. The need for other studies using other types of food as an alternative arrangement of food for patients with diabetes Keywords: diabetes mellitus type 2, AMPK-α2, yam flour Abstrak: Metode alternatif pengendalian kadar glukosa pada penderita DM adalah dengan pengaturan jenis makanan, salah satunya dengan memanfaatkan tepung gembili. Pada tepung terdapat inulin dan pati resisten yang dapat mengaktivasi enzim Ampk-α2. Aktivasi enzim ini akan menstimulasi transpor glukosa di otot skelet dan hepar, sehingga menyebabkan terjadinya penurunan produksi glukosa. Dosis bervariasi dari tepung diharapkan mampu berpengaruh terhadap ekspresi Ampk-α2. Penelitian ini bertujuan untuk hubungan dosis tepung gembili (Dioscorea esculenta dengan tigkat ekspresi enzim Ampk-α2 di nukleus otot skelet dan hepar pada model

  5. Estimation of dose ionizing radiation exposure by biological dosimetry; Estimación de dosis de exposición a radiaciones ionizantes mediante dosimetría biológica

    Energy Technology Data Exchange (ETDEWEB)

    Herranz Crespo, R.; Moreno Domene, M.; Prieto Rodríguez, M.J.; Lozano Barriuso, M.A.

    2014-07-01

    the Biological Dosimetry Laboratory of the Radiopathology Centre, at Hospital General Universitario Gregorio Marañón, is the only national laboratory accredited by UNE-EN ISO/IEC 17025:2005, and scope to ISO 19238:2004 (Radiation protection – Performance criteria for service laboratories performing biological dosimetry by citogenetics), for dose assessment by the dycentrics assay, has great experience with more than 100 real cases analyzed, and several population studies. This paper describes experience and results from more than 20 years of work under the Reference level II Centre for the attention of irradiated and/or contaminated people. [Spanish] El Laboratorio de Dosimetría Biológica, del Centro de Radiopatología del Hospital General Universitario Gregorio Marañón, es el único en España que dispone de acreditación internacional por la norma UNE-EN ISO/IEC 17025:2005 con alcance a la norma ISO 19238:2004 (Radiationprotection – Performance criteria for service laboratories performing biological dosimetry by citogenetics), para la realización de estimaciones dosimétricas mediante la técnica de dicéntricos, dispone de amplia experiencia en su aplicación en los 110 casos reales analizados, y en diferentes estudios de poblaciones españolas. En este trabajo se describe la experiencia del laboratorio y los resultados obtenidos en los más de 20 años de funcionamiento en el Centro de Referencia de nivel II para la atención a irradiados y/o contaminados por radiaciones ionizantes.

  6. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  7. Occupational dose control in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Viktorsson, C.; Lochard, J.; Benedittini, M.; Baum, J.; Khan, T.A.

    1990-01-01

    Reduction in occupational exposure at nuclear power plants is desirable not only in the interest of the health and safety of plant personnel, but also because it enhances the safety and reliability of the plants. This report summarises the current trends of doses to workers at nuclear power plants and the achievements and developments regarding methods for their reduction

  8. Computer Based Dose Control System on Linear Accelerator

    International Nuclear Information System (INIS)

    Taxwim; Djoko-SP; Widi-Setiawan; Agus-Budi Wiyatna

    2000-01-01

    The accelerator technology has been used for radio therapy. DokterKaryadi Hospital in Semarang use electron or X-ray linear accelerator (Linac)for cancer therapy. One of the control parameter of linear accelerator isdose rate. It is particle current or amount of photon rate to the target. Thecontrol of dose rate in linac have been done by adjusting repetition rate ofanode pulse train of electron source. Presently the control is stillproportional control. To enhance the quality of the control result (minimalstationer error, velocity and stability), the dose control system has beendesigned by using the PID (Proportional Integral Differential) controlalgorithm and the derivation of transfer function of control object.Implementation of PID algorithm control system is done by giving an input ofdose error (the different between output dose and dose rate set point). Theoutput of control system is used for correction of repetition rate set pointfrom pulse train of electron source anode. (author)

  9. Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3D); Untersuchungen zur Bildqualitaet, Hochkontrastaufloesung und Dosis am Stamm- und Gliedmassenskelett mit einem neuen dedizierten CT-System (ISO-C-3D)

    Energy Technology Data Exchange (ETDEWEB)

    Rock, C.; Kotsianos, D.; Linsenmaier, U. [Klinikum der Universitaet Muenchen, Muenchen (Germany). Inst. fuer Klinische Radiologie; Fischer, T. [Klinikum der Universitaet Muenchen, Muenchen (DE). Inst. fuer Klinische Radiologie] (and others)

    2002-02-01

    Purpose: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. Material and Methods: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3d). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). Results: Adequate image quality (mean score values 3-4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2-3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). Conclusion: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures. (orig.) [German] Zielsetzung: Evaluierung der 3D-CT-Bildgebung mit einem C-Bogen-basierten dedizierten CT-System (ISO-C-3D, Fa. Siemens) an Extremitaetengelenken und am Stammskelett. Methodik: 27 humane Leichenpraeparate der unteren und oberen Extremitaet sowie des Stammskeletts wurden am ISO-C-3D untersucht und die Bilddaten anhand eines Bildqualitaetsscores von 3 Untersuchern semiquantitativ evaluiert (Score 1: nicht

  10. Baixas doses de bupivacaína a 0,5% isobárica para raquianestesia unilateral Bajas dosis de bupivacaína a 0,5% isobárica para raquianestesia unilateral Low isobaric 0.5% bupivacaine doses for unilateral spinal anesthesia

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Imbelloni

    2004-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A raquianestesia unilateral pode apresentar diversas vantagens, principalmente no paciente ambulatorial. Baixas doses de anestésicos locais, lenta velocidade de injeção subaracnóidea e posição de decúbito lateral são relacionados com a facilidade de produzir distribuição unilateral na raquianestesia. Neste estudo, foi verificada a possibilidade de se obter raquianestesia unilateral com bupivacaína a 0,5% isobárica. MÉTODO: A raquianestesia com 1 ml de bupivacaína isobárica a 0,5% (5 mg foi realizada através de agulha 27G Quincke em 25 pacientes, estado físico ASA I e II submetidos à cirurgias ortopédicas. A punção subaracnóidea foi realizada por via lateral com o paciente em decúbito lateral, com o membro a ser operado voltado para cima, e 1 ml de bupivacaína isobárica foi injetado na velocidade de 1 ml.30s-1. Bloqueios sensitivo e motor (picada de agulha e escala de 0 a 3 foram comparados entre os lados a ser operado e o contralateral. RESULTADOS: Os bloqueios motor e sensitivo entre o lado operado e o contralateral foram significativamente diferentes em todos os tempos avaliados. No membro operado todos os pacientes apresentaram anestesia cirúrgica. No membro contralateral, aos 20 minutos, 9 pacientes apresentaram bloqueio sensitivo; aos 40 minutos 18 pacientes e aos 60 minutos 17 pacientes. Portanto, o bloqueio sensitivo unilateral ocorreu em 7 pacientes (28% e em ambos os membros em 18 pacientes (72%. Raquianestesia unilateral foi obtida em 28% dos pacientes. Estabilidade hemodinâmica foi observada em todos os pacientes. Nenhum paciente desenvolveu cefaléia pós-punção dura-máter. CONCLUSÕES: A bupivacaína isobárica (5 mg proporciona predominante bloqueio unilateral após 20 minutos na posição lateral. A solução isobárica de bupivacaína se mobiliza dentro do LCR após 20 minutos, resultando num bloqueio unilateral em apenas 28% dos pacientes. A principal vantagem da

  11. Baixa dose de bupivacaína isobárica, hiperbárica ou hipobárica para raquianestesia unilateral Baja dosis de bupivacaína isobara, hiperbara o hipobara para anestesia raquidea unilateral Low dose isobaric, hyperbaric, or hypobaric bupivacaine for unilateral spinal anesthesia

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Imbelloni

    2007-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A raquianestesia unilateral pode apresentar vantagens principalmente em pacientes em regime ambulatorial. Baixa dose da solução anestésica, velocidade lenta da injeção espinal e a posição lateral facilitam a obtenção da distribuição unilateral na raquianestesia. Foram comparadas soluções isobárica, hiperbárica e hipobárica de bupivacaína com objetivos de se obter raquianestesia unilateral em pacientes submetidos a intervenções cirúrgicas ortopédicas em regime ambulatorial. MÉTODO: Cento e cinqüenta pacientes foram aleatoriamente separados em três grupos para receberem 5 mg de bupivacaína a 0,5% isobárica (Grupo Iso, ou 5 mg de bupivacaína a 0,5% hiperbárica (Grupo Hiper, ou 5 mg de bupivacaína a 0,15% hipobárica (Grupo Hipo. As soluções foram administradas no interespaço L3-L4 com o paciente na posição lateral e permanecendo nesta posição por 20 minutos. A anestesia sensitiva foi avaliada pelo teste da picada da agulha. O bloqueio motor avaliado pela escala modificada de Bromage. Ambos os bloqueios foram comparados com o lado não operado e entre si. RESULTADOS: Existiu diferença significativa entre o lado operado e não-operado em todos os três grupos aos 20 minutos, mas maior freqüência de raquianestesia unilateral foi obtida com as soluções hiperbárica e hipobárica de bupivacaína. Bloqueio sensitivo e motor foram observados em 14 pacientes do Grupo Iso, 38 pacientes no Grupo Hiper e 40 pacientes no Grupo Hipo. Não ocorreram alterações hemodinâmicas em nenhum paciente. Não foram observados cefaléia pós-punção nem sintomas neurológicos temporários. CONCLUSÕES: A raquianestesia com soluções hipobárica e hiperbárica proporcionou maior freqüência de unilateralidade. Após 20 minutos a solução isobárica de bupivacaína mobilizou-se no líquido cefalorraquidano (LCR, resultando em apenas 28% de raquianestesia unilateral.JUSTIFICATIVA Y OBJETIVOS: La

  12. Studies on supramolecular gel formation using DOSY NMR

    Czech Academy of Sciences Publication Activity Database

    Nonappa, N.; Šaman, David; Kolehmainen, E.

    2015-01-01

    Roč. 53, č. 4 (2015), s. 256-260 ISSN 0749-1581 Institutional support: RVO:61388963 Keywords : DOSY * VT NMR * gel * diffusion coefficients Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.226, year: 2015

  13. Investigation of the impact of dose fluctuations on tumour control

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.; Royal Adelaide Hospital,; Booth, J.; Adelaide University,; Rosenfeld, A.

    2001-01-01

    Full text: The importance of spatial uniformity of the dose across the Planning Target Volume (PTV) has been investigated previously with the conclusion stated in 'uniform dose theorem' concluding that the uniform dose results in the highest Tumour Control Probability (TCP). The dose fluctuations, which appear in fractionated treatments as a result of setup errors, organ motion, treatment machine calibration and other reasons can be seen as temporal dose non-uniformity. The intuitive expectation, that the temporal dose non-uniformity would also reduce TCP, has been tested. The impact of temporal dose non-uniformity has been investigated considering intra and inter-treatment dose fluctuations. The dose was considered to be spatially uniform. The convolution technique was used and analytical expression of TCP accounting for the dose fluctuation has also been derived. Both techniques used Probability Density Function (PDF) to account for the dose fluctuations. The dose fluctuations with PDF symmetrical around its mean value (Gaussian) as well as non-symmetrical PDFs were both investigated. The symmetrical PDFs represented the fluctuations, which appear in the whole PTV as a result of day to day variation in treatment machine output. Non-symmetrical PDFs represented the dose fluctuations at the edges of PTV as a result of setup errors and organ motion. The effect of the dose fluctuations has been expressed in terms of an extra dose δ (positive or negative) which should be added to the value of temporally uniform dose in order to provide the same TCP as the one resulting from temporally non-uniform (fluctuating) dose. Intra-treatment dose fluctuations resulted in an increased TCP, though the effect is relatively small (δ<1 Gy for the treatment dose of 60 Gy). However, inter-treatment fluctuations of the dose reduced TCP for a patient population. The size of effect increases with the standard deviation of the PDF. Random ultra-treatment dose fluctuations resulted in

  14. Radiological dose and metadata management; Radiologisches Dosis- und Metadatenmanagement

    Energy Technology Data Exchange (ETDEWEB)

    Walz, M.; Madsack, B. [TUeV SUeD Life Service GmbH, Aerztliche Stelle fuer Qualitaetssicherung in der Radiologie, Nuklearmedizin und Strahlentherapie Hessen, Frankfurt (Germany); Kolodziej, M. [INFINITT Europe GmbH, Frankfurt/M (Germany)

    2016-12-15

    This article describes the features of management systems currently available in Germany for extraction, registration and evaluation of metadata from radiological examinations, particularly in the digital imaging and communications in medicine (DICOM) environment. In addition, the probable relevant developments in this area concerning radiation protection legislation, terminology, standardization and information technology are presented. (orig.) [German] Dieser Artikel stellt die aktuell in Deutschland verfuegbaren Funktionen von Managementsystemen zur Erfassung und Auswertung von Metadaten zu radiologischen Untersuchungen insbesondere im DICOM-Umfeld (Digital Imaging and Communications in Medicine) vor. Ausserdem werden die in diesem Bereich voraussichtlich relevanten Entwicklungen von Strahlenschutzgesetzgebung ueber Terminologie und Standardisierung bis zu informationstechnischen Aspekten dargestellt. (orig.)

  15. Regulatory aspects of low doses control in Albania

    International Nuclear Information System (INIS)

    Dollani, K.; Kushe, R.

    1997-01-01

    In the present paper are described the status of regulatory aspects of low doses control as well as the existing procedures for their implementation in Albania. According to new Radiological Protection Act, approved by Parliament in 1995, the establishment of the infrastructures in radiation protection area is in course, accompanied by the installation and functioning of new equipment for low dose control. Based in many years experience it is concluded that personal doses of the workers added by practices in Albania are 1/10 of dose Emits. Some particular cases of overexposured workers were investigated. Last times the elements of the optimisation procedures (QA and QC) are outlined in the frame of improving regulatory aspects of low doses control. (author)

  16. The Measurement of Integrated Gamma-Ray Doses in the Range 50 Mrad to 5 Mrad Using Phosphate Glass and Lithium Fluoride; Mesure, au Moyen de Verre au Phosphate et de Fluorure de Lithium, de Doses Integrees de Rayons Gamma de 50 Mrad a 5 Mrad; 0418 0417 041c 0414 ; Medicion de Dosis Integradas de Rayos Gamma de 50 Mrad a 5 Mrad por Medio de Vidrio al Fosfato y de Fluoruro de Litio

    Energy Technology Data Exchange (ETDEWEB)

    Webb, G. A.M. [Central Electricity Generating Board, Berkeley Nuclear Laboratories, Berkeley, Glos. (United Kingdom)

    1965-06-15

    'a pas fait l'objet de recherches aussi poussees. Le verre comme le fluorure de lithium peuvent etre recuits et reutilises, et l'auteur a essaye differents cycles de recuit pour chacun d'eux; il a egalement mesure la sensibilite en cas de reutilisation. Il a etudie pour chaque systeme les effets de la temperature d'irradiation et de la temperature d'entreposage entre 20 et 100 Degree-Sign C et a mesure les doses dans des flux mixtes de neutrons et de rayons gamma. L'auteur compare les deux systemes du point de vue de leurs usages generaux et de leurs possibilites d'application dans des cas particuliers. (author) [Spanish] Como base de sistemas dosimetricos para el intervalo de dosis de rayos y de 50 mrad a 5 Mrad, el autor ha comparado la radiofotoluminiscencia y la alteracion del color del vidrio al fosfato con la termoluminiscencia del fluoruro de litio. Midio la luminiscencia inducida en un vidrio al fosfato de bajo numero atomico, activado con plata, con ayuda de un fluorometro comercial (dosimetro Toshiba de vidrio fluorado) completado con- un espectrofotometro para medir las variaciones de la densidad optica en la region de las dosis elevadas. Estudio los efectos de diversos procedimientos para limpiar el vidrio. La termoluminiscencia del fluoruro de litio se midio con un aparato de lectura de laboratorio a fin de obtener curvas de luminosidad, integrandose seguidamente la superficie situada bajo el pico apropiado. El espectro de emision de la termoluminiscencia se determino empleando filtros opticoe que sirvieron tambien para reducir lo mas posible los efectos debidos a la radiacion infrarroja procedente de la placa calentadora. Se estudiaron los efectos ejercidos sobre el pico de tribotermoluminiscencia por los filtros opticos y por una atmosfera de nitrogeno. El funcionamiento de ambos sistemas se ha estudiado y comparado segun diversos criterios. El vidrio abarca un intervalo muy amplio, desde 5 * 10{sup -2} a 5 * 10{sup 6} rad, es decir, un intervalo dinamico

  17. 1997 N-Basin Administrative Control Level Dose Extension

    International Nuclear Information System (INIS)

    Nellesen, A.L.

    1997-04-01

    This document provides justification for extending the Administrative Control Level of 500 mrem per year to 1,000 mrem per year Total Effective Dose Equivalent for workers involved with N-Reactor Basin Deactivation in accordance with established procedures

  18. Calibration and quality control for personnel dose meter

    International Nuclear Information System (INIS)

    Wu Rongtao; Zhang Dianqin

    1999-01-01

    Calibration and quality control are the important aspects to assure thermoluminescence dose measurement compliance with the technical standards. The author discussed some problems to implement technical standards and regulations

  19. Dose control and ALARA at nuclear power plants

    International Nuclear Information System (INIS)

    Xia Yihua; Li Xutong

    1999-01-01

    With the development of NPPs in China, paying attention to dose control and ALARA at NPPs is very important. The author briefly introduces two primary tasks for exposure control at NPPs, primary consideration of ALARA and the common technical methods. It points out that adoption of some quantitative indicators is useful, but it is important to bear it in mind that these ' values of dose avoided' are situation specific

  20. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  1. DOSIS & DOSIS 3D: radiation measurements with the DOSTEL instruments onboard the Columbus Laboratory of the ISS in the years 2009-2016

    Science.gov (United States)

    Berger, Thomas; Burmeister, Sönke; Matthiä, Daniel; Przybyla, Bartos; Reitz, Günther; Bilski, Pawel; Hajek, Michael; Sihver, Lembit; Szabo, Julianna; Ambrozova, Iva; Vanhavere, Filip; Gaza, Ramona; Semones, Edward; Yukihara, Eduardo G.; Benton, Eric R.; Uchihori, Yukio; Kodaira, Satoshi; Kitamura, Hisashi; Boehme, Matthias

    2017-03-01

    The natural radiation environment in Low Earth Orbit (LEO) differs significantly in composition and energy from that found on Earth. The space radiation field consists of high energetic protons and heavier ions from Galactic Cosmic Radiation (GCR), as well as of protons and electrons trapped in the Earth's radiation belts (Van Allen belts). Protons and some heavier particles ejected in occasional Solar Particle Events (SPEs) might in addition contribute to the radiation exposure in LEO. All sources of radiation are modulated by the solar cycle. During solar maximum conditions SPEs occur more frequently with higher particle intensities. Since the radiation exposure in LEO exceeds exposure limits for radiation workers on Earth, the radiation exposure in space has been recognized as a main health concern for humans in space missions from the beginning of the space age on. Monitoring of the radiation environment is therefore an inevitable task in human spaceflight. Since mission profiles are always different and each spacecraft provides different shielding distributions, modifying the radiation environment measurements needs to be done for each mission. The experiments "Dose Distribution within the ISS (DOSIS)" (2009-2011) and "Dose Distribution within the ISS 3D (DOSIS 3D)" (2012-onwards) onboard the Columbus Laboratory of the International Space Station (ISS) use a detector suite consisting of two silicon detector telescopes (DOSimetry TELescope = DOSTEL) and passive radiation detector packages (PDP) and are designed for the determination of the temporal and spatial variation of the radiation environment. With the DOSTEL instruments' changes of the radiation composition and the related exposure levels in dependence of the solar cycle, the altitude of the ISS and the influence of attitude changes of the ISS during Space Shuttle dockings inside the Columbus Laboratory have been monitored. The absorbed doses measured at the end of May 2016 reached up to 286

  2. Efeitos da associação entre pequenas doses subaracnóideas de morfina e cetoprofeno venoso e oral em pacientes submetidas à cesariana Efectos de la asociación entre pequeñas dosis subaracnóideas de morfina y cetoprofeno venoso y oral en pacientes sometidas a cesariana Effects of low spinal morphine doses associated to intravenous and oral ketoprofen in patients submitted to cesarean sections

    Directory of Open Access Journals (Sweden)

    Eliana Marisa Ganem

    2003-08-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Pequenas doses subaracnóideas de morfina são eficazes em reduzir a dor pós-operatória de pacientes submetidas à cesariana, com menor incidência de efeitos colaterais. O objetivo desta pesquisa foi avaliar a qualidade da analgesia pós-operatória e a ocorrência de efeitos colaterais em pacientes submetidas a cesarianas, sob anestesia subaracnóidea com bupivacaína hiperbárica e morfina nas doses de 0,05 mg e 0,1 mg, associadas ao cetoprofeno pelas vias venosa e oral. MÉTODO: Participaram do estudo 60 gestantes de termo, estado físico ASA I e II, que foram submetidas à cesariana eletiva. As pacientes foram divididas em dois grupos: grupo 1 - morfina 0,1 mg, grupo 2 - 0,05 mg, associada a 15 mg de bupivacaína hiperbárica. Todas receberam cetoprofeno (100 mg por via venosa no per-operatório e por via oral a cada 8 horas no primeiro dia de pós-operatório. As pacientes foram avaliadas 6, 12 e 24 horas após o término da cirurgia, com relação à intensidade da dor e presença de efeitos colaterais (sedação, prurido, náusea e vômito. A presença destes últimos também foi avaliada no per-operatório. RESULTADOS: Ambos os grupos foram idênticos quanto aos dados antropométricos e à duração da cirurgia e da anestesia. Também foram homogêneos com relação à intensidade da dor pós-operatória e à presença de prurido, sedação, náusea e vômito. CONCLUSÕES: A morfina, nas doses de 0,05 mg e 0,1 mg administradas no espaço subaracnóideo, associada ao cetoprofeno pelas vias venosa e oral, apresentou a mesma qualidade de analgesia pós-operatória e determinou a mesma ocorrência de efeitos colaterais.JUSTIFICATIVA Y OBJETIVOS: Pequeñas dosis subaracnóideas de morfina son eficaces en reducir el dolor pos-operatorio de pacientes sometidas a cesariana, con menor incidencia de efectos colaterales. El objetivo de esta pesquisa fue evaluar la calidad de la analgesia pos-operatoria y la ocurrencia

  3. Rapid Estimation of Fast-Neutron Doses following Radiation Exposure in Criticality Accidents: The S{sup 32}(n, p)P{sup 32} Reaction in Body Hair; Prompte Evaluation des Doses de Neutrons Rapides apres une Exposition au Rayonnement a la Suite d'Accidents de Criticite: Reaction {sup 32}S(n, p){sup 32}P dans le Systeme Pileux; 0411 042b 0421 0414 ; Evaluacion Acelerada de Dosis de Neutrones Rapidos Despues de una Irradiacion Consecutiva a un Accidente de Criticidad: La Reaccion {sup 32}S(n, p){sup 32}P en el Pelo

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, D. F. [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1965-06-15

    de fission exige environ six heures pour une evaluation preliminaire. Des experiences a l'aide du spectre de fission bien defini provenant d'un assemblage critique non blinde fournissent constamment des evaluations de dose de neutrons ne s'ecartant pas plus de 10% en plus et en moins des mesures dosimetriques de reference. En outre, du fait de la position anatomique fixe des echantillons pileux, on. peut connaitre l'orientation et le parametre d'asymetrie de l'exposition en comparant les activites specifiques d'echantillons provenant de differentes regions du corps. On a constate a l'occasion de trois emballements critiques qui ont fait des victimes que, dans chaque cas, les expositions etaient nettement dissymetriques. Ainsi, le dosage du {sup 32}P sur le systeme pileux fournit des renseignements complementaires de grande valeur que l'on peut comparer avec les evaluations de l'exposition totale du corps aux neutrons par la mesure de la teneur du sang en {sup 24}Na. Des estimations du rendement de fission, fondees sur les geometries deduites dans chaque cas, concordent bien avec les evaluations independantes des fissions totales obtenues par des methodes analytiques plus classiques. Pour la determination approximative rapide de la dose des neutrons rapides, il suffit de multiplier par 0,49 l'activite du {sup 32}P dans le cheveu ou dans le poil, exprimee en desintegrations par minute et par gramme, a la temperature O, obtenue avec tout ensemble de comptage d'une sensibilite connue,- pour obtenir la dose en rad des neutrons dits de la 'bande du soufre'. (author) [Spanish] Dada su composicion quimica constante, su situacion anatomica fija y la facilidad con que pueden sacarse muestras, el pelo humano constituye un material muy util para determinar en poco tiempo las dosis de neutrones rapidos recibidas por el personal afectado por accidentes de criticidad. El contenido en azufre del cabello y del pelo humano es notablemente uniforme y no depende del sexo, del color o de

  4. Robust predictive control strategy applied for propofol dosing using BIS as a controlled variable during anesthesia

    NARCIS (Netherlands)

    Ionescu, Clara A.; De Keyser, Robin; Torrico, Bismark Claure; De Smet, Tom; Struys, Michel M. R. F.; Normey-Rico, Julio E.

    This paper presents the application of predictive control to drug dosing during anesthesia in patients undergoing surgery. The performance of a generic predictive control strategy in drug dosing control, with a previously reported anesthesia-specific control algorithm, has been evaluated. The

  5. Remote control and data processing for measurement of radiation dose

    International Nuclear Information System (INIS)

    Zhou Yu; Luo Yisheng; Guo Yong; Ji Gang; Wang Xinggong; Zhang Hong; Zhang Wenzhong

    2004-01-01

    Objective: To protect the workers from the reactor radiation and to improve the accuracy and efficiency of neutron dose measurement. Methods: With the application of remote control technology, a remote control and automatic measurement system for radiation dose measurement(especially for neutron dose) was set up. A Model 6517A electrometer was operated all automatically over RS-232 serial interface using SCPI commands with a computer. Results: The workers could stay far from the reactor and be able to control the portable computer in site though internet or LAN and then to control the 6517A electrometer to implement the dose measurement. After the measurement, the data were transferred to the remote computer near the workers and shared by many experts at the first time through the net. Conclusion: This is the first time that the remote control technology is applied in radiation dose measurement, which has so far been considered can only be performed at a near place. This new system can meet the need of neutron radiobiology researches as well as of the safety and health of the workers. (author)

  6. RESPUESTA DEL PASTO RAIGRASS AUBADE (Lolium sp. A DOSIS DE SILICIO EN INTERACCION CON DIFERENTES DOSIS DE NPK

    Directory of Open Access Journals (Sweden)

    DIANA LEGARDA - LOPEZ

    Full Text Available El presente trabajo se realizó en el corregimiento de Catambuco, municipio de Pasto, localizado a 01°06'33 N y 77°19 '07.8 WO; con el objeto de conocer El presente trabajo se realizó en el corregimiento de Catambuco, municipio de Pasto, localizado a 01°06 '33 N y 77°19´07.8 WO; con el objeto de conocer con tres repeticiones y 10 tratamientos distribuidos en dosis altas, medias y bajas de NPK (Altas: 529 kg/ha de úrea, 72 kg/ha de SFT, 160 kg/ha de KCl. Medias: 397 kg/ha de urea, 54 kg/ha de SFT, 120 kg/ha de KCl. Bajas: 265 kg/ha de úrea, 36 kg/ha de SFT, 80 kg/ha de KCl contrastadas con dosis altas, medias y bajas de Si (Alta 100 kg/ha, media 75 kg/ha, baja 50 kg/ha de SiO2 y un testigo sin fertilización con Si. El Si en dosis alta y NPK alto, presentó mejores resultados en altura de planta (101cm, producción de forraje verde (167,2 Ton/ha/año, materia seca (27,44 Ton/ha/año, concentraciones de P (parte aérea 0,53%y raíz 0,42%,de K (parte aérea 3,11% y raíz 2,27%. Al aplicar dosis altas y medias en el suelo,la concentración de P y K disminuyó. El tratamiento dosis alta de NPK y alta de Si presentó el mayor beneficio económico, seguido del tratamiento dosis media de NPK y alta de Si.

  7. Evaluación de los cambios ocasionados en espermatozoides bovinos por variaciones en el manejo de las dosis durante su manipulación en inseminación artificial Evaluation of changes ocassioned by changes in bovine sperm in the management of dose during handling artificial insemination

    OpenAIRE

    S.F. Bernardi; R. Allende; R. Mazzeo; J Monti; P.R Marini

    2011-01-01

    Considerando el disímil manejo al que las dosis son sometidas durante el descongelado y antes de la inseminación, el objetivo del presente trabajo fue determinar el efecto que estos cambios producen sobre distintas características morfológicas y funcionales de los espermatozoides afectando la calidad del semen a inseminar. Se utilizaron muestras de un toro Holando Argentino, procesadas y congeladas en pajuelas de 0,5 cc utilizando un diluyente semidefinido. El análisis de la motilidad se real...

  8. Analysis of the response dependence of Ebt3 radiochromic film with energy, dose rate, wavelength, scanning mode and humidity; Analisis de la dependencia de la respuesta de la pelicula radiocromica EBT3 con la energia, tasa de dosis, longitud de onda, modo de escaneo y con la humedad

    Energy Technology Data Exchange (ETDEWEB)

    Leon M, E. Y.; Camacho L, M. A. [Universidad Autonoma del Estado de Mexico, Facultad de Medicina, Laboratorio de Fotomedicina, Biofotonica y Espectroscopia Laser de Pulsos Ultracortos, Jesus Carranza y Paseo Tollocan s/n, 50120 Toluca, Estado de Mexico (Mexico); Herrera G, J. A.; Garcia G, O. A. [Instituto Nacional de Neurologia y Neurocirugia, Laboratorio de Fisica Medica y Unidad de Radiocirugia, 14269 Ciudad de Mexico (Mexico); Villarreal B, J. E., E-mail: yaz_3333@hotmail.com [University of Calgary, Department of Oncology, Tom Baker Cancer Centre, 1331 29th street NW Calgary, Alberta T2N 4N2 (Canada)

    2016-10-15

    With the development of new modalities in radiotherapy treatments, the use of radiochromic films has increased considerably. Because the characteristics that presented, they are suitable for quality control and dose measurement. In this work and analysis of the dependence of the response of Ebt3 radiochromic films with energy, dose rate, wavelength, scan mode and humidity, for a dose range of 0-70 Gy is presented. According to the results, the response of Ebt3 radiochromic films has low dependence on energy, dose rate, scan mode and humidity. However, the sensitivity of the response Ebt3 radiochromic films has a high dependence on the wavelength of the optical system used for reading. (Author)

  9. Dose controlled low energy electron irradiator for biomolecular films.

    Science.gov (United States)

    Kumar, S V K; Tare, Satej T; Upalekar, Yogesh V; Tsering, Thupten

    2016-03-01

    We have developed a multi target, Low Energy Electron (LEE), precise dose controlled irradiator for biomolecular films. Up to seven samples can be irradiated one after another at any preset electron energy and dose under UHV conditions without venting the chamber. In addition, one more sample goes through all the steps except irradiation, which can be used as control for comparison with the irradiated samples. All the samples are protected against stray electron irradiation by biasing them at -20 V during the entire period, except during irradiation. Ethernet based communication electronics hardware, LEE beam control electronics and computer interface were developed in house. The user Graphical User Interface to control the irradiation and dose measurement was developed using National Instruments Lab Windows CVI. The working and reliability of the dose controlled irradiator has been fully tested over the electron energy range of 0.5 to 500 eV by studying LEE induced single strand breaks to ΦX174 RF1 dsDNA.

  10. Dose controlled low energy electron irradiator for biomolecular films

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S. V. K., E-mail: svkk@tifr.res.in; Tare, Satej T.; Upalekar, Yogesh V.; Tsering, Thupten [Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400 005 (India)

    2016-03-15

    We have developed a multi target, Low Energy Electron (LEE), precise dose controlled irradiator for biomolecular films. Up to seven samples can be irradiated one after another at any preset electron energy and dose under UHV conditions without venting the chamber. In addition, one more sample goes through all the steps except irradiation, which can be used as control for comparison with the irradiated samples. All the samples are protected against stray electron irradiation by biasing them at −20 V during the entire period, except during irradiation. Ethernet based communication electronics hardware, LEE beam control electronics and computer interface were developed in house. The user Graphical User Interface to control the irradiation and dose measurement was developed using National Instruments Lab Windows CVI. The working and reliability of the dose controlled irradiator has been fully tested over the electron energy range of 0.5 to 500 eV by studying LEE induced single strand breaks to ΦX174 RF1 dsDNA.

  11. Methionine Uptake and Required Radiation Dose to Control Glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Iuchi, Toshihiko, E-mail: tiuchi@chiba-cc.jp [Division of Neurological Surgery, Chiba Cancer Center, Chiba (Japan); Hatano, Kazuo [Division of Radiation Oncology, Tokyo Bay Advanced Imaging and Radiation Oncology Clinic, Makuhari, Chiba (Japan); Uchino, Yoshio [Division of Nuclear Medicine, Chiba Ryogo Center, Chiba (Japan); Itami, Makiko [Division of Surgical Pathology, Chiba Cancer Center, Chiba (Japan); Hasegawa, Yuzo; Kawasaki, Koichiro; Sakaida, Tsukasa [Division of Neurological Surgery, Chiba Cancer Center, Chiba (Japan); Hara, Ryusuke [Division of Radiation Oncology, Chiba Cancer Center, Chiba (Japan)

    2015-09-01

    Purpose: The purpose of this study was to retrospectively assess the feasibility of radiation therapy planning for glioblastoma multiforme (GBM) based on the use of methionine (MET) positron emission tomography (PET), and the correlation among MET uptake, radiation dose, and tumor control. Methods and Materials: Twenty-two patients with GBM who underwent MET-PET prior to radiation therapy were enrolled. MET uptake in 30 regions of interest (ROIs) from 22 GBMs, biologically effective doses (BEDs) for the ROIs and their ratios (MET uptake:BED) were compared in terms of whether the ROIs were controlled for >12 months. Results: MET uptake was significantly correlated with tumor control (odds ratio [OR], 10.0; P=.005); however, there was a higher level of correlation between MET uptake:BED ratio and tumor control (OR, 40.0; P<.0001). These data indicated that the required BEDs for controlling the ROIs could be predicted in terms of MET uptake; BED could be calculated as [34.0 × MET uptake] Gy from the optimal threshold of the MET uptake:BED ratio for tumor control. Conclusions: Target delineation based on MET-PET was demonstrated to be feasible for radiation therapy treatment planning. MET-PET could not only provide precise visualization of infiltrating tumor cells but also predict the required radiation doses to control target regions.

  12. A remotely operated drug delivery system with dose control

    KAUST Repository

    Yi, Ying

    2017-05-08

    “On demand” implantable drug delivery systems can provide optimized treatments, due to their ability to provide targeted, flexible and precise dose release. However, two important issues that need to be carefully considered in a mature device include an effective actuation stimulus and a controllable dose release mechanism. This work focuses on remotely powering an implantable drug delivery system and providing a high degree of control over the released dose. This is accomplished by integration of a resonance-based wireless power transfer system, a constant voltage control circuit and an electrolytic pump. Upon the activation of the wireless power transfer system, the electrolytic actuator is remotely powered by a constant voltage regardless of movements of the device within an effective range of translation and rotation. This in turn contributes to a predictable dose release rate and greater flexibility in the positioning of external powering source. We have conducted proof-of-concept drug delivery studies using the liquid drug in reservoir approach and the solid drug in reservoir approach, respectively. Our experimental results demonstrate that the range of flow rate is mainly determined by the voltage controlled with a Zener diode and the resistance of the implantable device. The latter can be adjusted by connecting different resistors, providing control over the flow rate to meet different clinical needs. The flow rate can be maintained at a constant level within the effective movement range. When using a solid drug substitute with a low solubility, solvent blue 38, the dose release can be kept at 2.36μg/cycle within the effective movement range by using an input voltage of 10Vpp and a load of 1.5 kΩ, which indicates the feasibility and controllability of our system without any complicated closed-loop sensor.

  13. Difference in Injury Mode, Dose-Rate Dependence and RBE of 730-Mev Protons, 100-KVp X-Rays and 250-KVp X-Rays; Differences dans le Type de Lesion, l'Importance du Debit de Dose et l'EBR entre les Protons de 730 Mev, les Rayons X de 100 Kv-Crete et les Rayons X de 250 Kv-Crete; Razlichiya kharaktera porazheniya, zavisimosti ot moshchnosti dozy i obeh protonov s ehnergiej 730 mehv i rentgenovskikh luchej s pikovym napryazheniem 100 i 250 kv; Diferencias en la Modalidad de La Lesion, la Relacion con la Intensidad de Dosis y la EBR de los Protones de 730 Mev, y los Rayos X de 100 Kvp Y de 250 Kvp

    Energy Technology Data Exchange (ETDEWEB)

    Sondhaus, C. A.; Wallace, R. W.; Lyman, J. T.; Kase, K. W.; Steward, P. G. [University of California Lawrence Radiation Laboratory Berkeley (United States)

    1964-03-15

    meme effet du debit de doee que dans l'exposition a bas TLE. Les auteurs examinent les consequences pratiques de la distribution de la dose et du debit de dose. (author) [Spanish] Los autores estudiaron la mortalidad a los 6, 12 y 30 d en ratones blancos machos de la variedad Swiss Webster expuestos a protones de 730 MeV, a rayos X de 250 kVp y a rayos X de 100 kVp, con diferentes intensidades de dosis. En los ratones irradiados con protones, predomino la muerte por sindrome gastrointestinal, a los 6 a 8 d, con dosis de 100 y 1000 rad/min, y el efecto letal fue mas intenso con la intensidad de dosis mayor. En la exposicion a los rayos X, predomino la muerte por sindrome hematopoyetico, a los 12 a 14 d, con efectos de la intensidad de dosis semejantes a los del caso anterior. Comprobaron los autores que la EBR de los protones para la DL{sub 50} a los 30 d, comparada con la de los rayos X de 250 kVp, asciende a 0,8; en cuanto a la EBR para la DL{sub 50} a los 6 d, es 1,2, con igual intensidad de dosis (100 rad/min). Atribuyen la diferencia de modalidad de la lesion a las distintas distribuciones de la dosis en los tejidos. En la EBR de los protones para la muerte por sindrome intestinal a los 6 d , que asume un valor elevado pero variable, se manifiesta al parecer el efecto de intensidad de doeis caracteristico de las exposiciones de baja TLE. Los autores examinan las consecuencias practicas de los factores de distribucion de dosis y de la intensidad de dosis senalados. (author) [Russian] Izuchalas' smertnost' samcov belyh myshej linii Sviss Vebster, podvergnutyh oblucheniju protonami s jenergiej 730 Mjev, rentgenovskimi luchami s pikovym naprjazheniem 250 i 100 kv pri razlichnyh moshhnostjah dozy. Myshi, obluchennye protonami, pogibali na shestoj- vos'moj den', glavnym obrazom v rezul'tate zheludochno-kishechnyh porazhenij posle obluchenija 100 i 1000 rad/min, prichem smertnost' povyshalas' s povysheniem moshhnosti dozy. Posle rentgenovskogo obluchenija zhivotnye

  14. Problems is applying new internal dose coefficients to radiation control

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi [Oarai Laboratory, Chiyoda Technol Corporation, Ibaraki (Japan)

    1998-06-01

    The author discussed problems concerning the conceivable influence in the radiation control and those newly developing when the new internal dose coefficients are applied in the law in the future. For the conceivable influence, the occupational and public exposure was discussed: In the former, the effective dose equivalent limit (at present, 50 mSv/y) was thought to be reduced and in the latter, the limit to be obscure although it might be more greatly influenced by the new coefficients. For newly developing problems, since the new biological model which is more realistic was introduced for calculation of the internal dose and made the calculation more complicated, use of computer is requisite. The effective dose of the internal exposure in the individual monitoring should be conveniently calculated as done at present even after application of the new coefficients. For calculation of the effective dose of the internal exposure, there are such problems as correction of the inhaled particle size and of the individual personal parameter. A model calculation of residual rate in the chest where the respiratory tract alone participated was presented as an example but for the whole body, more complicated functions were pointed out necessary. The concept was concluded to be incorporated in the law in a convenient and easy manner and a software for calculation of internal dose using the new coefficients was wanted. (K.H.)

  15. Evaluation of Dose: Comparative Effect of Fast Neutrons and other Types of Radiation on the Survival of E. Coli and S. Cerevisiae; Evaluation de la Dose Delivree et Actions Comparees des Neutrons Rapides et d'Autres Radiations sur la Survie de E. Coli et S. Cerevisiae; Otsenka dozy i sravnitel'noe vliyanie bystrykh nejtronov i drugikh vidov izlucheniya na vyzhivaemost' E. Coli i S. Cerevisiae; Evaluacion de la Dosis Suministrada y Comparacion de la Accion de los Neutrones Rapidos sobre la Supervivencia del E. Coli y del S. Cerevisiae con la de Otras Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, Y.; Bocquet, C. [Centre d' Etudes Nucleaires de Saclay (France)

    1964-05-15

    diverses radiations dependent de l'organisme vivant etudie, du critere biologique choisi, mais aussi de la dose d'irradiation avec laquelle on fait la comparaison. L'efficacite biologique relative apparait dans ces experiences comme etant egalement une fonction de la dose. L'action des neutrons rapides et des rayons X releve souvent de processus radiobiologique differents. Il est arbitraire de relier entre elles les doses de ces diverses radiations par des relations lineaires. (author) [Spanish] Junto al reactor EL3 se encuentra un convertidor de uranio que permite obtener neutrones rapidos. Con una bateria de camaras de fision se mide el flujo y la distribucion espectral de los neutrones rapidos. Estos micro- detectores estan colocados en diversos puntos del volumen que se ha de irradiar y permiten evaluar experimentalmente la dosis absorbida en los tejidos. Gracias a este dispositivo y a este sistema de dosimetria, los autores han podido comparar la accion de los neutrones rapidos con las de otras radiaciones ionizantes (rayos X, rayos y) sobre organismos unicelulares. En este trabajo, estudian el porcentaje de supervivencia y la frecuencia de una mutacion morfologica en el Saccharomyces cerevisiae. Tambien han trazado la curva de supervivencia del Escherichia coli, expuesto a rayos X y a neutrones. La observacion de los resultados indica que los efectos biologicos relativos de estas diversas radiaciones dependen del organismo vivo estudiado, del criterio biologico elegido y, ademas, de la dosis de irradiacion con que se realiza la comparacion. Tambien se deduce de estos experimentos que la eficacia biologica relativa es funcion de la dosis. A menudo, la accion de los neutrones rapidos y de los rayos X depende de diferentes procesos radiobiologicos. Seria arbitrario establecer relaciones lineales entre las dosis de dichas radiaciones. (author) [Russian] Na reaktore EL-3 imeetsja uranovyj preobrazovatel, pozvoljajushhij poluchat' bystrye nejtrony. Batareja kamer delenija

  16. Point absorbed dose verification for volumetric modulated arc therapy plans. A comparative study between ionization microchamber and chamber array; Verificacion de dosis absorbida en un punto para planes de arcoterapia volumetrica modulada. Estudio comparativo entre microcamara de ionizacion y matriz de camaras

    Energy Technology Data Exchange (ETDEWEB)

    Caudepon Moreno, F.; Pizarro Trigo, F.; Sanchez Jimenez, J.; Nunez Martinez, L.; Morillas Ruiz, J.; Palomo Llinares, R.

    2016-10-01

    According to the international recommendations a quality control must be made for IMRT treatments before these can be delivered. These recommendations are applied to volumetric modulated arc therapy treatments in our Department. As a part of the verifications chain, measurements of absorbed dose in a phantom point and in the phantom volume are made for a specific patient with ionization chamber and ionization chambers array, respectively. The aim of this issue is to compare measurements of absorbed dose between these two kinds of detectors. The predictions of absorbed dose from Treatment Planning System are taken as the reference one. The differences among these measurements and the reference are calculated for 105 specific patients. A statistical analysis shows that the measurements of absorbed dose with chamber and array are strongly correlated. This result allows us to eliminate from our verifications chain the measurements of absorbed dose in a phantom point with ionization chamber because these ones are included in measurements of absorbed dose in the volume with a very small statistic risk. As a result, much time can be saved in the verifications process without any lack of quality. (Author)

  17. Determination of the dose equivalent Hp(0.07) in hands of occupationally exposed personnel in the practice of proton emission tomography (PET/CT); Determinacion de la dosis equivalente Hp(0.07) en manos de trabajadores ocupacionalmente expuestos en la practica de Tomografia por Emision de Positrones (PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Lea, D. [Servicio de Radiofisica Sanitaria, Unidad de Tecnologia Nuclear, Instituto Venezolano de Investigaciones Cientificas, Ministerio de Ciencia y Tecnologia, Km 11 Carretera Panamerican, Altos del Pipe, Caracas (Venezuela); Ruiz, N.; Esteves, L. [Centro Diagnostico Docente Las Mercedes, Calle Paris cruce con calle Caroni, Edif. CDD, Las Mercedes, Caracas (Venezuela)]. e-mail: dlea@ivic.ve

    2006-07-01

    In Venezuela recently it was implanted the Positron Emission Tomography technique (PET) with the perspective of implanting it at national level. Even when in our country practices it of nuclear medicine it exists from early of 70, there is not experience in the determination of the occupational doses by exposure to the external radiation in hands. By this reason, a concern exists in the workers of the centers of nuclear medicine where it is practiced the Positron Emission Tomography technique. In absence of the TLD dosimetry to measure dose in hands in our country, measurements of the dose equivalent of the workers of the PET national reference center were made, using a detector of hands type diode. It was determined the dose in hands in terms of dose equivalent Hp(0.07) in two work positions, that is: the corresponding to the transfer of the receiving vial of ({sup 18}F) FDG to the shield, quality control and uni doses division. The second work position corresponds the person in charge of administering, via intravenous, the ({sup 18}F) FDG. In this work it realizes the dose equivalent in hands Hp(0.07) measures in each one of the work positions before described by daily production. The informed doses correspond to a total average produced activity of 20.4 GBq (550 mCi). The results of the measurements in terms of dose equivalent in hands Hp(0.07) correspond to 2.1 {+-} 20% mSv in the work position of division and 0.4 {+-} 10% mSv in the position of injection of the radioactive material. At short term this foreseen until 4 productions per week, what means an annual dose equivalent Hp(0.07) in hands of 400 mSv approximately, without taking into account abnormal situations as its are spills of the ({sup 18}F) FDG in the work place. This work is the starting point so that the regulatory authority settles down, in Venezuela, dose restrictions in the PET practices and implant, in the centers of nuclear medicine, an optimization politics of this practice in conformity

  18. A model for automation of radioactive dose control

    International Nuclear Information System (INIS)

    Ribeiro, Carlos Henrique Calazans; Zambon, Jose Waldir; Bitelli, Ricardo; Honaiser, Eduardo Henrique Rangel

    2009-01-01

    The paper presents a proposal for automation of the personnel dose control system to be used in nuclear medicine environments. The model has considered the Standards and rules of the National Commission of Nuclear Energy (CNEN) and of the Health Ministry. The advantages of the model is a robust management of the integrated dose and technicians qualification status. The software platform selected to be used was the Lotus Notes and an analysis of the advantages, disadvantages of the use of this platform is also presented. (author)

  19. A model for automation of radioactive dose control

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Carlos Henrique Calazans; Zambon, Jose Waldir; Bitelli, Ricardo; Honaiser, Eduardo Henrique Rangel [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil)], e-mail: calazans@ctmsp.mar.mil.br, e-mail: zambon@ctmsp.mar.mil.br, e-mail: bitelli@ctmsp.mar.mil.br, e-mail: honaiser@ctmsp.mar.mil.br

    2009-07-01

    The paper presents a proposal for automation of the personnel dose control system to be used in nuclear medicine environments. The model has considered the Standards and rules of the National Commission of Nuclear Energy (CNEN) and of the Health Ministry. The advantages of the model is a robust management of the integrated dose and technicians qualification status. The software platform selected to be used was the Lotus Notes and an analysis of the advantages, disadvantages of the use of this platform is also presented. (author)

  20. Dose control in road transport of radioactive material

    International Nuclear Information System (INIS)

    Gerulis, Eduardo

    2013-01-01

    The radiation doses to workers in the transport of radioactive material should be as low as reasonably achievable. The average doses of drivers and loaders, sampled in this thesis should be decreased. The demonstration of doses control in a road vehicle with radioactive material required by the current Brazilian regulation, CNEN NE 5.01 should be written in its own printed form with exposure values obtained in normally occupied positions from workers and members of the public, even when the consignment does not need 'exclusive use' (⅀IT ≤50). Through bibliographic research, modeling and field research, this research work shows that this demonstration of the control should be done by writing the registration accumulation of load, limited (⅀IT ≤50), also in the own printed form. It is for a better control method, in order to avoid the use of measuring equipment, to build standardization with foreign regulations, to the current occupational doses of radioprotection technicians, the costs and time, (important for consignment with radiopharmaceuticals short half-life) would be all smaller. Exposure values of the parameters used with this method are smaller than regulatory limits. The segregation distances between loads and the cabins of vehicles shall be showed by Brazilian regulation updated to contribute to these aims. (author)

  1. Application and inspiration of risk control in dose control in Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Yu Shaoqing; Chen Yan; Chai Jianshe; Zhang Chunming

    2013-01-01

    The article introduced the basic concept of risk and risk control methods. Using the risk control methods, we analyzed and evaluated the actions to control dose of public and occupational radiation exposure in the Fukushima Dai-ichi nuclear power plant accident, especially found out the weak points of these actions, and finally discussed the application of the risk control methods in dose management during nuclear accidents. (authors)

  2. Association of Papillary Thyroid Carcinoma and Graves' Disease. Unexpected Development and Efficiency of Ablative Dose with Recombinant Human Thyrotropin (rhTSH); Asociación de carcinoma papilar de tiroides y enfermedad de Graves. Inesperada evolución y eficacia de la dosis ablativa con tirotrofina recombinante humana (rhTSH)

    Energy Technology Data Exchange (ETDEWEB)

    Pacenza, N. A.; Groppo, N. [Centro Médico “Enrique Tortosa”, Consultorio de Endocrinología, Buenos Aires (Argentina); Guibourg, H. C. [Sigma Imágenes Médicas S.A., Servicio de Medicina Nuclear, Buenos Aires (Argentina)

    2013-07-01

    with {sup 99m}Tc pertechnetate: {sup P}athological uptake in middle and lower cervical region right and left lower neck. He was reoperated on 4 months after his initial S: {sup R}esection of epithelial proliferation with thyroid aspect in superior mediastinum region{sup .} Pathology: {sup N}ode with extensive infiltration of neoplastic proliferation of follicular variant of papillary carcinoma with areas of connective tissue infiltrated periganglionar of papillary thyroid cancer{sup .} Lab 40 days after the second surgery: TSH 2.3 μIU/mL, FT4 0.82 ng/dL, Tg 4.7 ng/mL. Neck and chest CT showed neither pathological lesions nor lymphadenopathy. I{sup 131} uptake with 7.4 MBq was: 1st hour: 8 % and 24 hours: 12 %. Neck Scan: {sup M}ultiple areas of tracer fixation in the neck{sup .} No pathological signs on neck palpation. Ablative dose of 7.4 GBq of I{sup 131} was performed to the patient, previously using rhTSH (two doses of 0.9 mg), reaching TSH >100 μIU/mL. Scan post ablative dose: {sup I}mportant focus on right paratracheal region. Neck MRI showed: Absence of thyroid gland. Rounded image of about 10 mm at right paratracheal level. The patient initiates suppressive therapy with levothyroxine (LT4). Six months after ablation therapy (without LT4): TSH >100 μIU/mL, Tg: 13.8 ng/mL, TGA: 431 IU/mL. Body Scan with 2 mCi: {sup P}athological focus of radioiodine behind the right sternoclavicular joint. New neck MRI: Image in right pretracheal region smaller than the previous study{sup .} The patient received 5.55 GBq of I{sup 131}. The same radioiodine treatment was repeated 8 months later. At present, 4 years after the patient's initial surgery, he is in good general health, performing his normal activities, with TGA in sharp decline, negative I{sup 131}body scan and without signs of persistent or recurrent disease. Conclusions: We report a case of follicular variant papillary TC associated with GD with concomitant development of hyperthyroidism, with positive TGA, in a

  3. Controllable dose: a discussion on the control of individual doses from single sources

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1999-01-01

    Contaminated land is an issue of considerable interest in many countries. It arises as a result of accidental releases, as from Chernobyl, and from manmade activities including atmospheric testing of nuclear weapons. Contamination is also an historic liability from, for example, plants using radium, or from excessive effluent discharges. A particular issue at present is the decommissioning of nuclear facilities, old reactors and weapons fabrication facilities. These liabilities require the expenditure of considerable amounts of money and some people think that too much money is being, and will be, spent to achieve low levels of residual contamination. If contaminated land is not cleaned up there is public concern and in some countries there will be litigation, charging that the environmental risk is too great. These concerns have led to an increased pressure from some individuals to propose a threshold in the dose-response relationship in order to reduce the expenditure. It is true that, increasingly, our science is judged in the courts rather than by national academies os science. Judge and jury will decide on the issue of the threshold and it is they who must be convinced as to whether there are no risks at low doses of radiation. The issue is primarily in relation to public non occupational exposure, and because of the continuing lack of definitive scientific evidence, a new approach to protection could be considered (author)

  4. Controllable dose: a discussion on the control of individual doses from single sources

    International Nuclear Information System (INIS)

    Clarke, R.

    1999-01-01

    Contaminated land is an issue of considerable interest in many countries. It arises as a result of accidental releases, as from Chernobyl, and from manmade activities including atmospheric testing of nuclear weapons. Contamination is also an historic liability from, for example, plants using radium, or from excessive effluent discharges. A particular issue at present is the decommissioning of nuclear facilities, old reactors and weapons fabrication facilities. These liabilities require the expenditure of considerable amounts of money and some people think that too much money is being, and will be, spent to achieve low levels of residual contamination. If contaminated land is not cleaned up these is public concern and in some countries there will be litigation, charging that the environmental risk is too great. These concerns have led to an increased pressure from some individuals to propose a threshold in the dose-responses relationship in order to reduce the expenditure. It is true that, increasingly, our science is judged in the courts rather by national academies of sciences. Judge and jury decide on the issue to the threshold and it is they who must convinced as to whether there are no risks at low doses of radiation. The issue is primarily in relation to public not occupational exposure, and because of the continuing lack of definitive scientific evidence, a new approach to protection could be considered. (author)

  5. Control of hypertension with single daily doses of sotalol hydrochloride.

    Science.gov (United States)

    Gabriel, R

    A study was carried out in 12 previously untreated hypertensive patients to assess the efficacy of sotalol given in a once-daily dosage regimen. After an initial dosage titration period (mean 3 weeks) during which diastolic pressure was stabilized at less than 100 mmHg, all patients were satisfactorily maintained on a constant once-daily dose of sotalol for 3 months. Eight of the 12 patients required 320 mg or less daily (mean dose 190 mg). Whilst blood pressure remained controlled for at least 26 hours after daily doses the pulse rate, counted at the same time, showed escape from beta-blockade. Side-effects (vivid dreams) were reported in only 1 patient.

  6. Synthesis of optimal digital controller of flocculant dosing

    Directory of Open Access Journals (Sweden)

    A.V. Pismenskiy

    2013-06-01

    Full Text Available Purpose. The task of automatic process control of the slime water thickening and flotation tailings clarification is the stabilization of thicken product density within the given range and keeping up the solids content in the overflow not above the permissible level with minimum use of the flocculants. In existing systems for automatic control the flocculant dosing is carried out according to the solids content in the device input (the principle of open-loop control. This leads to the excess consumption of the flocculants and increase the dispersion density of the overflow. To perform the synthesis of the optimal digital controller in order to minimize the deviations from the master control and ensure the specified quality of the transition process. Over controlling value should not exceed 5 %. To perform the system operation modeling in order to determine the quality of transient processes. Methodology. Synthesis of the optimal digital controller is based on the method of dynamic programming. Findings. A mathematical model of the object control is represented in the normal form of Cauchy and further in the form of differential equations. The optimum period of quantization as the function from specified error of control and the output coordinate change is calculated. The differential equation of Bellman is obtained and the condition for minimization of the quality functional. Bellman function is represented as a quadratic form from the variables of the system condition. In order to limit possible control, the weight coefficients of the functional are calculated based on maximum permitted values of the system condition variables and the control actions during the transient process. Practical value. Using the modeling of ACS of the flocculant dosing it was established that the over controlling amount is 3.5%, the transient process life 5.6 sec, the transient process is aperiodical, non-static control, which meets the requirements imposed on the

  7. Dose control programme of Hot Cell facility at Isotope Wing

    International Nuclear Information System (INIS)

    Sapkal, Jyotsna A.; Suresh, Manju; Shreenivas, V.; Amruta, C.T.; Yadav, R.K.B.; Gopalkrishanan, R.K.; Patil, B.N.; Sastry, K.V.S.

    2015-01-01

    Hot Cell Facility of Board of Radiation Isotope Technology (BRIT) at Radiological Laboratories (RLG) is involved in fabrication of sealed radioisotopes like Cobalt-60, Cesium-137 and Iridium-192 radioisotopes which are widely used for various medical and industrial applications. In the field of Medicine, above radioactive sources are used for treatment procedures such as Teletherapy and Brachytherapy. 192 Ir radioisotope is widely used for industrial radiography particularly for non-destructive testing of welds in steel in the oil and gas industries. In spite of the increased production of these radioisotopes to meet the requirements from medical and industrial sector, the annual Collective Dose for BRIT facility, during 2011-2013 has shown a downward trend. This paper describes in brief the measures adopted by the facility based on the radiological safety inputs provided by Radiation Hazards Control (RHC) Unit of Isotope Wing, RLG for reducing the collective dose during year 2012 and 2013 by nearly 40% of collective dose consumed for year-2011. Strict implementation of the radiological safety measures during handling of radioactive sources, administrative controls and engineered safety measures resulted in lowering of collective dose during year 2011-2013. (author)

  8. Quality control in pulsed dose rate brachytherapy; Controle de qualite en curietherapie de debit de dose pulse

    Energy Technology Data Exchange (ETDEWEB)

    Metayer, Y.; Brunaud, C.; Peiffert, D. [Centre Alexis-Vautrin, Unite de Radiophysique, 54 - Vandoeuvre-les-Nancy (France); Meyer, P. [Centre Paul-Strauss, 67 - Strasbourg (France)

    2009-07-15

    A prospective multicenter study (P.D.R.) was leaded on pulsed dose rate brachytherapy over 2 years (2005/2006) in 20 French centres, as part of a programme entitled (Support for the innovative and expensive techniques) S.t.i.c.-P.D.R. and supported by the French ministry of health. Eight hundred and fifty patients were treated for cervix carcinoma with 2D classic or 3D innovative brachytherapy (425 in each arm). The main objectives of this study were to assess the cost of P.D.R. brachytherapy with dose optimization compared to traditional treatments, and to evaluate the complications and local control. A joint programme of quality control was established by the physicists of the different centres, concerning the software treatment planning, the source replacement, the projector and the technical parameters of the course of patient treatment. This technical note lists these controls, and their frequency. (authors)

  9. Should we routinely remove the dose delivered by the images of control?; Faut-il systematiquement retirer la dose delivree par les images de controle?

    Energy Technology Data Exchange (ETDEWEB)

    Goasduff, G. [Centre Hospitalier Universitaire Morvan, Service de Radiotherapie, 29 - Brest (France); Pene Baverez, D.; Pradier, O.; Bouchekoua, M. [Service de Radiotherapie, 29 - Brest (France)

    2009-10-15

    The constraints of doses fixed by the international commission on radiation units and measurements (ICRU) for the target volume (95-107% of the prescribed dose) are respected. for the hypo fractionated treatments, it is necessary to control the impact of the dose delivered by the control images for every patient. The dose delivered at the isocenter is estimated between 1 and 3 Gy by control image: this dose depends on the beams size and on the distance-source-skin. Protocols of the patient positioning checking must be implemented on optimizing their frequency to limit the dose received by the patient. (N.C.)

  10. Dosis de radiación ultravioleta en escolares mexicanos

    Directory of Open Access Journals (Sweden)

    Castanedo-Cázares Juan Pablo

    2003-01-01

    Full Text Available OBJETIVO: Determinar la dosis de radiación ultravioleta que reciben los niños y adolescentes durante su asistencia a la escuela primaria, secundaria o preparatoria en la ciudad de San Luis Potosí. MATERIAL Y MÉTODOS: Estudio de cohorte hecho en la ciudad de San Luis Potosí entre mayo de 2001 y abril de 2002. Se evaluaron 80 escolares escogidos al azar de 6 a 19 años de edad, de uno u otro sexo. La dosis se cuantificó durante todo un ciclo escolar mediante el registro del tiempo de exposición solar para cada uno de los alumnos, de modo simultáneo al monitoreo de radiación ultravioleta, para lo cual se utilizaron equipos de radiometría terrestre. Se excluyeron las vacaciones y los fines de semana. Los datos se analizaron en forma univariada y comparativamente, por sexo y meses de exposición; además, se buscó un modelo de regresión para explicar la dosis de exposición solar. RESULTADOS: La dosis promedio ajustada al espectro de eritematógeno acción fue de 16 456 J/m²/año.Hubo diferencias por género: 14 264 J/m²/año/mujeres vs. 18 648 J/m²/año/hombres (Kolmogorov-Smirnof, p=0.003. No hubo diferencias significativas entre grupos, pero sí entre los meses de exposición (Kruskall-Wallis, p=<0.0001. Utilizando la técnica estadística de modelos lineales generalizados, y mediante técnica escalonada y calificación del índice de Akaike se escogió el mejor modelo que explica la dosis de radiación según el mes de exposición, mediante la fórmula 587.20+438.45 (género+500.16(mes-49.65(mes². El resultado muestra mayores dosis de radiación de marzo a septiembre. CONCLUSIONES: Proponemos un marco teórico para la creación de políticas dirigidas a proteger a los alumnos de la sobrexposición solar durante su asistencia a la escuela en México. Se justifica la implantación de medidas preventivas durante al menos el periodo de mayor exposición (marzo a junio, ya que en este lapso se recibe 51% de la dosis anual de radiaci

  11. Putting aside the LNT dilemma in the controllable dose concept

    International Nuclear Information System (INIS)

    Koblinger, Laszlo

    2000-01-01

    Recently, Professor R. Clarke, ICRP Chairman has published his proposal for a renewal of the basic radiation protection concept. The two main points of his proposed system are: (1) the term Controllable Dose is introduced, and (2) the protection philosophy is based on the individual. For practical uses terms like 'Action Level', 'Investigation Level' etc. are introduced. The outline of the new system promises a really less complex frame; no distinction between practices and interventions, unified treatment for occupational, medical and public exposures. There is, however, an inconsistency within the new system: Though linearity is not assumed, the relations between the definitions of the new terms of the system of protection and the doses assigned to them are still based on the LNT hypothesis. To avoid this discrepancy a new definition of Action Level is recommended as a conservative estimate of the lowest dose where harmful effects have ever been demonstrated. Other levels should be defined by the Action Level and Safety Factors applied on the doses. (author)

  12. Program analysis and presentation of results of the profiles and depth dose rates obtained with the PTW software MC{sub 2} MEPHYSTO; Programa de analisis y presentacion de resultados de los perfiles y porcentajes de dosis en profundidad adquiridos con el software MEPHYSTO MC2 de PTW

    Energy Technology Data Exchange (ETDEWEB)

    Tato de la Cuevas, F.

    2011-07-01

    In the periodic quality control of linear accelerators is usually included acquisition and analysis of profiles and PDDs (percentage depth dose). In the protocol of Quality Control of electron accelerators for clinical use of the proposed analysis SEFM 4 Profiles for each of the energies used clinically. This involves a large number of curves to be analyzed and the subsequent introduction of the parameters in a spreadsheet or similar for your assessment as to the reference state. We have developed a program that analyzes the curves acquired by mcc Mephysto PTW software and presents the results of that analysis in a spreadsheet.

  13. Dose control during decommissioning stage 1.2 of decommissioning SGHWR facility

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, M.J. [AEA Technology (United Kingdom)

    1995-12-31

    Dose control during decommissioning stage 1.2 of the SGHWR facility, i.e preparation for an extended period of care and maintenance, is discussed. The method of control of dose uptake is described and also the systems of dose uptake review, the use of dose restraint objections and other tools for limitation of dose uptake. Dose uptake data are presented for periods of maintenance shutdowns. Finally the option of chemical clearing of the circuit following shutdown is considered. (UK).

  14. Quality control procedure of the BNCT patient dose determination

    International Nuclear Information System (INIS)

    Bjugg, H.; Kortesniemi, M.; Seppaelae, T.; Karila, J.; Perkioe, J.; Ryynaenen, P.; Savolainen, S.; Auterinen, I.; Kotiluoto, P.; Seren, T.

    2000-01-01

    The concepts used at the Finnish BNCT facility for the patient dose quality assurance are introduced here. Dose planning images are obtained using a MR scanner with MRI sensitive markers. The dose distribution is computed with BNCT Rtpe. The program and the beam (DORT) model used have been verified with measurements and validated with MCNP calculations in phantoms. Dosimetric intercomparison has been done between FiR 1 and BMRR BNCT beams. The FiR 1 beam has been characterised also by visiting teams. Before every patient irradiation the relationship between beam monitor pulse rate and neutron fluence rate in the beam is checked by activation measurements. Cross-hair lasers used in the patient positioning are checked for spatial drift prior to each treatment. Kinetic models used to estimate the time-behaviour of blood boron concentration have been verified using independent patient sample data to assess and verify the performance of the applications. Quality control guides have been developed for each step in the patient irradiation. (author)

  15. Simulation of dose deposition in heterogeneities in the human body, using the Penelope code for photons beams of energies of a linear accelerator; Simulacion de la deposicion de dosis en las heterogeneidades del cuerpo humano, usando el codigo Penelope para haces de fotones de energias de un acelerador lineal

    Energy Technology Data Exchange (ETDEWEB)

    Cardena R, A. R.; Vega R, J. L.; Apaza V, D. G., E-mail: cardroj@yahoo.es [Universidad Nacional de San Agustin, Av. Independencia s/n, Arequipa (Peru)

    2015-10-15

    The progress in cancer treatment systems in heterogeneities of human body has had obstacles by the lack of a suitable experimental model test. The only option is to develop simulated theoretical models that have the same properties in interfaces similar to human tissues, to know the radiation behavior in the interaction with these materials. In this paper we used the Monte Carlo method by Penelope code based solely on studies for the cancer treatment as well as for the calibration of beams and their various interactions in mannequins. This paper also aims the construction, simulation and characterization of an equivalent object to the tissues of the human body with various heterogeneities, we will later use to control and plan experientially doses supplied in treating tumors in radiotherapy. To fulfill the objective we study the ionizing radiation and the various processes occurring in the interaction with matter; understanding that to calculate the dose deposited in tissues interfaces (percentage depth dose) must be taken into consideration aspects such as the deposited energy, irradiation fields, density, thickness, tissue sensitivity and other items. (Author)

  16. Respuesta de frijol al Endospor 33® a dosis 50% de fertilizante nitrogenado/fosfatado en agricultura protegida

    Directory of Open Access Journals (Sweden)

    Juan Manuel Sanchez-Yañez

    2014-01-01

    Full Text Available El frijol requiere fertilización nitrogenada y fosfatada (FNP, cuya indiscriminada aplicación causa pérdida de productividad del suelo, una alternativa de solución para este problema es reducir y optimizar la dosis de FNP con un inoculante mixto con bacterias promotoras de crecimiento vegetal (BPCV y hongos micorricicos vesículo arbusculares (HMA. El objetivo de esta investigación fue analizar la respuesta del frijol al inoculante mixto Endospor 33® a dosis reducida al 50% del FNP. En un suelo ferralítico rojo pobre de Nitrógeno (N y materia orgánica. Con un diseño experimental de bloques al azar con 5 tratamientos y 6 repeticiones. Los resultados indican que el porcentaje de germinación del frijol con Endospor 33® a la dosis 20 mg/semilla fue de 100%. A plántula con 10 mg/planta, tuvo 6,13g de peso fresco total (PFT y de 0,66g de peso seco total (PST comparado con el frijol control relativo (CR con 0,28g de PST con el 100% del FNP. A floración con 30 mg/planta Endospore 33® tuvo 1,5g de PST comparado con 1,07g de PST del frijol CR. A madurez fisiológica con 30mg/planta registro 34,83g/100 semillas, en contraste a su homologo CR con 20,39g/100 semillas. Lo anterior indica que este inoculante mixto es una opción en la producción del frijol a dosis reducida del FNP, sin afectar negativamente su crecimiento y/o rendimiento.

  17. Correlação entre métodos de avaliação da qualidade da dose de diálise La correlación entre los métodos de evaluación de la calidad de la dosis de diálisis Comparison between two methods for evaluation of the dialysis dose quality

    Directory of Open Access Journals (Sweden)

    Kelly Cristina Inoue

    2009-01-01

    Full Text Available OBJETIVO: Verificar a correlação entre o Kt/V calculado e o Kt/V-OCM. MÉTODOS: Estudo transversal, retrospectivo, com 14 pacientes submetidos a 106 hemodiálises com a máquina Fresenius 4008S, realizado numa Unidade de Terapia Intensiva para adultos, de um Hospital de Ensino do noroeste do Paraná, no período de novembro/2007 a abril/2008. RESULTADOS: Através do teste de Shapiro-Wilk, (p>0,05, foi constatado que não houve distribuição normal entre o "Kt/V calculado" e o "Kt/V da máquina". CONCLUSÃO: Pelo teste de Wilcoxon concluiu-se que houve diferença significativa (pOBJETIVO: Verificar la correlación entre el Kt/V calculado y el Kt/V-OCM. MÉTODOS: Estudio transversal, retrospectivo, con 14 pacientes sometidos a 106 hemodiálisis con la máquina Fresenius 4008S, realizado en una Unidad de Cuidados Intensivos para adultos, de un Hospital Docente del noroeste del Paraná, en el período de noviembre/2007 a abril/2008. RESULTADOS: A través del test de Shapiro-Wilk, (p>0,05, se constató que no hubo distribución normal entre el "Kt/V calculado" y el "Kt/V de la máquina". Por el test de Wilcoxon hubo diferencia significativa (pPURPOSE: To compare calculated Kt/V and Kt/V-OCM methods of dialysis dose. METHODS: This was a cross-sectional retrospective study with 14 patients who underwent 106 hemodialysis using Fresenius 4008S dialysis machine in the critical care unit of the "Noroeste Parana Teaching Hospital" from November 2007 to April 2008. RESULTS: Shapiro-Wilk test indicated that there was no normal distribution between the calculated Kt/V and the machine Kt/V (p>0.05. Wilcoxon test showed a statistically significant difference between the two measurements (p <.0001. CONCLUSION: There is a need for further studies that consider all factors involved with the online calculation of the urea depuration for the utilization of the Kt/V-OCM.

  18. DOSIS & DOSIS 3D: radiation measurements with the DOSTEL instruments onboard the Columbus Laboratory of the ISS in the years 2009–2016

    Directory of Open Access Journals (Sweden)

    Berger Thomas

    2017-01-01

    Full Text Available The natural radiation environment in Low Earth Orbit (LEO differs significantly in composition and energy from that found on Earth. The space radiation field consists of high energetic protons and heavier ions from Galactic Cosmic Radiation (GCR, as well as of protons and electrons trapped in the Earth’s radiation belts (Van Allen belts. Protons and some heavier particles ejected in occasional Solar Particle Events (SPEs might in addition contribute to the radiation exposure in LEO. All sources of radiation are modulated by the solar cycle. During solar maximum conditions SPEs occur more frequently with higher particle intensities. Since the radiation exposure in LEO exceeds exposure limits for radiation workers on Earth, the radiation exposure in space has been recognized as a main health concern for humans in space missions from the beginning of the space age on. Monitoring of the radiation environment is therefore an inevitable task in human spaceflight. Since mission profiles are always different and each spacecraft provides different shielding distributions, modifying the radiation environment measurements needs to be done for each mission. The experiments “Dose Distribution within the ISS (DOSIS” (2009–2011 and “Dose Distribution within the ISS 3D (DOSIS 3D” (2012–onwards onboard the Columbus Laboratory of the International Space Station (ISS use a detector suite consisting of two silicon detector telescopes (DOSimetry TELescope = DOSTEL and passive radiation detector packages (PDP and are designed for the determination of the temporal and spatial variation of the radiation environment. With the DOSTEL instruments’ changes of the radiation composition and the related exposure levels in dependence of the solar cycle, the altitude of the ISS and the influence of attitude changes of the ISS during Space Shuttle dockings inside the Columbus Laboratory have been monitored. The absorbed doses measured at the end of May 2016

  19. Dose estimate for effective internal contamination in the occupationally exposed workers(OEW) that handling open sources for thyroid therapy using {sup 131} I (3779); Estimacion de la dosis efectiva por contaminacion interna en los trabajadores ocupacionalmente expuestos (TOE) que manipulan fuentes abiertas para el tratamiento de tiroides con {sup 131}I (3779)

    Energy Technology Data Exchange (ETDEWEB)

    Lecuna, J.A.; Carrizales, L.I., E-mail: jj1211g@yahoo.com, E-mail: lcarriza@ivic.gob.ve [Instituto Venezolano de Investigaciones Cientificas (IVIC), Caracas (Venezuela, Bolivarian Republic of); Dantas, B.M., E-mail: bmdantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    Handling of a variety of unsealed sources in Nuclear Medicine has led a significant risk of internal exposure of workers. {sup 131}I stands out among the radionuclides of frequent use due its wide application in diagnosis and treatment of thyroid diseases. The increasing radionuclide use for medical purposes and treatment of diseases creates a need for capable methodologies of controlling the internal contamination of work. Currently, in Venezuela, there are about 17 Nuclear Medicine Services between public and private, of which 5 are operating; however, individual monitoring is still limited in the control of internal exposure. This work presents the development of bioassay techniques 'in vivo', in order to quantify the incorporation of {sup 131}I used in Nuclear Medicine. It also presents the research results of internal exposure of a group of workers involved in handling of therapeutic dose of {sup 131}I . The 'in vivo' detection system was calibrated with the thyroid simulator developed at the Institute of Radiologic Protection and Dosimetry (IRD, Rio de Janeiro - Brazil) and which also has the UTN-IVIC (Caracas - Venezuela). The results showed that the bioassay method developed in this work has sufficient sensitivity for its use in routine intake survey of workers in Nuclear Medicine. Between the two workers controlled in this study, both had measurable results in terms of incorporation. Therefore, it is important to keep control of it and also gives us the possibility to evaluate the incorporations in suspected accident. The highest estimate of the effective dose was 1,28x10{sup -5} Sv by inhalation and 1,27x10{sup -5} Sv by ingestion.

  20. Effect of the dose and route of administration of butylscopolamine on the reduction of the artifacts associated with intestinal peristalsis in abdominal magnetic resonance; Efecto de la dosis y la via de administracion de butilescopolamina en la disminucion de los artefactors asociados al peristaltismo intestinal en la RM abdominal

    Energy Technology Data Exchange (ETDEWEB)

    Dosda, R.; Marti-Bonmati, L. [Hospital Universitario Dr Peset. Valencia. Clinica Quiron. Valencia (Spain); Ronchera-Oms, C. [Hospital San Pablo-CEU. Moncada Valencia (Spain)

    1999-07-01

    To compare the effect of the route of administration (intravenous and oral) and the dose (40 mg and 80 mg) of butylscopolamine, determining its efficacy in reducing the noise associated with gastrointestinal movement in magnetic resonance (MR) images and the incidence and severity of associated adverse reactions. The present prospective, controlled, double-blind study included 80 patients who underwent abdominal MR. All the patients were given oral, high-density barium sulfate and were divided randomly into 4 groups of 20 patients each: a control group and 3 groups treated with 40 mg or 80 mg of oral butylscopolamine or 40 mg of intravenous butylscopolamine. Both the barium and the oral solutions were administered 25 to 30 minutes before the examination. the MR images were obtained with a STIR sequence (1487/100/44), and qualitative analysis of the noise was carried out using regions of interest situated in the background. The gastrointestinal noise was defined both by the mean and the standard deviation of the signal intensity of the air front of an behind the patient. The standard deviation of the air beside the patient was determined to confirm the absence of variations in noise inherent to MR. The adverse reactions to MR after 2 hours (immediate) and one day (late) were recorded. There were no significant differences among the groups with respect to sex, age or time interval between administration of the oral solution and the start of the sequence. The noise inherent to MR was not significantly different from one group to another (Student-Newman-Keuls test, p=0.71). Both the mean and the standard deviation of the intensity of the air situated in anteroposterior phase-encoding direction were significantly lower in the butylscopolamine groups than in the control group (Student-Newman-Keuls test, p=0.008). The most marked reduction was observed after the oral dose of 80 mg, followed by intravenous injection of 40 mg and the oral dose of 40 mg. Adverse reaction

  1. Influence of dose distribution homogeneity on the tumor control probability in heavy-ion radiotherapy

    International Nuclear Information System (INIS)

    Wen Xiaoqiong; Li Qiang; Zhou Guangming; Li Wenjian; Wei Zengquan

    2001-01-01

    In order to estimate the influence of the un-uniform dose distribution on the clinical treatment result, the Influence of dose distribution homogeneity on the tumor control probability was investigated. Basing on the formula deduced previously for survival fraction of cells irradiated by the un-uniform heavy-ion irradiation field and the theory of tumor control probability, the tumor control probability was calculated for a tumor mode exposed to different dose distribution homogeneity. The results show that the tumor control probability responding to the same total dose will decrease if the dose distribution homogeneity gets worse. In clinical treatment, the dose distribution homogeneity should be better than 95%

  2. Measurement of the dose by dispersed radiation in a lineal accelerator using thermoluminescent dosimeters of CaSO{sub 4}:Dy; Medicion de la dosis por radiacion dispersa en un acelerador lineal usando dosimetros termoluminiscentes de CaSO{sub 4}:Dy

    Energy Technology Data Exchange (ETDEWEB)

    Chavez C, N.; Torijano, E.; Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Herrera, A. [ISSSTE, Hospital Nacional 20 de Noviembre, Eje 7 Sur Felix Cuevas Esq. Av. Coyoacan, Col. del Valle, 03229 Mexico D. F. (Mexico)

    2014-08-15

    The thermoluminescence (Tl) is based on the principle of the luminescent in a material when is heated below their incandescence temperature. Is a technique very used in dosimetry that is based on the property that have most of the crystalline materials regarding the storage of the energy that they absorb when are exposed to the ionizing radiations. When this material has been irradiated previously, the radioactive energy that contains is liberated in form of light. In general, the principles that govern the thermoluminescence are in essence the same of those responsible for all the luminescent processes and, this way, the thermoluminescence is one of the processes that are part of the luminescence phenomenon. For this work, the dispersed radiation was measured in the therapy area of the lineal accelerator of medical use type Elekta, using thermoluminescent dosimeters of CaSO{sub 4}:Dy + Ptfe developed and elaborated in the Universidad Autonoma Metropolitana, Unidad Iztapalapa. With the dosimeters already characterized and calibrated, we proceeded to measure the dispersed radiation being a patient in treatment. The results showed values for the dispersed radiation the order of a third of the dose received by the patient on the treatment table at 30 cm of the direct beam and the order of a hundredth in the control area (4 m of the direct beam, approximately). The conclusion is that the thermoluminescent dosimeters of CaSO{sub 4}: Dy + Ptfe are appropriate to measure dispersed radiation dose in radiotherapy. (author)

  3. Low-dose irradiation for controlling prostate cancer

    International Nuclear Information System (INIS)

    Cuttler, J.M.

    2003-01-01

    Prostate cancer is the second most commonly diagnosed cancer among North American men and the second leading cause of death in those aged 65 and over. The American Cancer Society recommends testing those over age 50 who are expected to live at least 10 years, even though the ability of early detection to decrease prostate cancer mortality has not been demonstrated. So controversy exists about the appropriateness of screening because of the considerable economic and social burden of diagnosing and treating prostate cancer, coupled with the projected large increase in the number of new cases as the population ages. This very important public health issue could be addressed at low cost by total-body low-dose irradiation therapy to stimulate the patient's own defences to prevent and control most cancers, including prostate cancer, with no symptomatic side effects. (author)

  4. Upgrading NASA/DOSE laser ranging system control computers

    Science.gov (United States)

    Ricklefs, Randall L.; Cheek, Jack; Seery, Paul J.; Emenheiser, Kenneth S.; Hanrahan, William P., III; Mcgarry, Jan F.

    1993-01-01

    Laser ranging systems now managed by the NASA Dynamics of the Solid Earth (DOSE) and operated by the Bendix Field Engineering Corporation, the University of Hawaii, and the University of Texas have produced a wealth on interdisciplinary scientific data over the last three decades. Despite upgrades to the most of the ranging station subsystems, the control computers remain a mix of 1970's vintage minicomputers. These encompass a wide range of vendors, operating systems, and languages, making hardware and software support increasingly difficult. Current technology allows replacement of controller computers at a relatively low cost while maintaining excellent processing power and a friendly operating environment. The new controller systems are now being designed using IBM-PC-compatible 80486-based microcomputers, a real-time Unix operating system (LynxOS), and X-windows/Motif IB, and serial interfaces have been chosen. This design supports minimizing short and long term costs by relying on proven standards for both hardware and software components. Currently, the project is in the design and prototyping stage with the first systems targeted for production in mid-1993.

  5. Evaluation of the absorbed dose to the lungs due to Xe{sup 133} and Tc{sup 99m} (MAA); Evaluacion de la dosis absorbida en los pulmones debido al Xe{sup 133} y Tc{sup 99m} (MAA)

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez A, M.; Murillo C, F.; Castillo D, C.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Rojas P, E. [Instituto Peruano de Energia Nuclear, Av. Canada 1470, Lima (Peru); Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in lungs of an adult patient has been evaluated using the biokinetics of radiopharmaceuticals containing Xe{sup 133} or Tc{sup 99m} (MAA). The absorbed dose was calculated using the MIRD formalism, and the Cristy-and Eckerman lungs model. The absorbed dose in the lungs due to {sup 133}Xe is 0.00104 mGy/MBq. Here, the absorbed dose due to remaining tissue, included in the {sup 133}Xe biokinetics is not significant. The absorbed dose in the lungs, due Tc{sup 99m} (MAA), is 0.065 mGy/MBq. Approximately, 4.6% of the absorbed dose is due to organs like liver, kidneys, bladder, and the rest of tissues, included in the Tc{sup 99m} biokinetics. Here, the absorbed dose is very significant to be overlooked. The dose contribution is mainly due to photons emitted by the liver. (Author)

  6. New dose limits and distribution of annual doses for controlled groups

    International Nuclear Information System (INIS)

    Vukcevic, M.; Stankovic, S.; Kovacevic, M.

    1993-01-01

    The new calculations of neutron doses received by the population of Hiroshima and Nagasaki, as well as the epidemiological data on the incidence of fatal cancers in the survivors, had led to the conclusion that the risk estimates should be raised by the factor 2 or 3. In this work, the distribution of monthly doses for occupationals was analysed in order to determine the percent of workers who might be considered as overexposed, on the basis of the new dose limits. (author)

  7. Should we routinely remove the dose delivered by the images of control?

    International Nuclear Information System (INIS)

    Goasduff, G.; Pene Baverez, D.; Pradier, O.; Bouchekoua, M.

    2009-01-01

    The constraints of doses fixed by the international commission on radiation units and measurements (ICRU) for the target volume (95-107% of the prescribed dose) are respected. for the hypo fractionated treatments, it is necessary to control the impact of the dose delivered by the control images for every patient. The dose delivered at the isocenter is estimated between 1 and 3 Gy by control image: this dose depends on the beams size and on the distance-source-skin. Protocols of the patient positioning checking must be implemented on optimizing their frequency to limit the dose received by the patient. (N.C.)

  8. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  9. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  10. Dynamic flow control strategies of vehicle SCR Urea Dosing System

    Science.gov (United States)

    Lin, Wei; Zhang, Youtong; Asif, Malik

    2015-03-01

    Selective Catalyst Reduction(SCR) Urea Dosing System(UDS) directly affects the system accuracy and the dynamic response performance of a vehicle. However, the UDS dynamic response is hard to keep up with the changes of the engine's operating conditions. That will lead to low NO X conversion efficiency or NH3 slip. In order to optimize the injection accuracy and the response speed of the UDS in dynamic conditions, an advanced control strategy based on an air-assisted volumetric UDS is presented. It covers the methods of flow compensation and switching working conditions. The strategy is authenticated on an UDS and tested in different dynamic conditions. The result shows that the control strategy discussed results in higher dynamic accuracy and faster dynamic response speed of UDS. The inject deviation range is improved from being between -8% and 10% to -4% and 2% and became more stable than before, and the dynamic response time was shortened from 200 ms to 150 ms. The ETC cycle result shows that after using the new strategy the NH3 emission is reduced by 60%, and the NO X emission remains almost unchanged. The trade-off between NO X conversion efficiency and NH3 slip is mitigated. The studied flow compensation and switching working conditions can improve the dynamic performance of the UDS significantly and make the UDS dynamic response keep up with the changes of the engine's operating conditions quickly.

  11. Quality control of radiopharmaceutical dose calibrators in nuclear medicine unit

    International Nuclear Information System (INIS)

    Oliveira, C.F.M.; Lucindo Junior, C.R.; Lopes Filho, F.J.

    2015-01-01

    As part of the program to ensure quality in nuclear medicine unit, in addition to diagnostic procedures, are evaluated activity meters, which is intended to measure the aliquot of radiation of radionuclides and / or radiopharmaceuticals that are administered to patients undergoing diagnostic investigation and / or therapeutic treatment. The good operating condition of dose calibrators is essential to ensure efficiency, safety and reliability of the measurements, once the lack of accuracy in the responses of these equipments can cause significant errors in the activity administered to the patient and may result in poor quality images resulting in the repetition of examis and interference in the successful treatment of the patient. This study aims to, considering the need for constant evaluation of the functioning of the activity meters and the fact that this issue be part the responsibilities of the professional of radiology, perform quality control testing of these instruments in relation to the most recent norm of National Commission of nuclear Energy (CNEN-NN 3:05) in Brazil, that is also in according to the international standards and reference values established during acceptance testing of these instruments in a nuclear medicine service. For this, was made a review of specific literature and the use of barium, cobalt and cesium to the tests in a nuclear medicine service of the state of Pernambuco in Brazil. The obtained results of the specific tests utilized to verify the correct working of the dose calibrators show coherency with the resolutions of the CNEN-NN 3:05 and are also in agreement with the international standards to that the measurement of activities be made with accurate results and thereby contribute to the proper functioning of nuclear medicine service. (authors)

  12. Estudo prospectivo das repercussões de baixas doses de remifentanil na função sinoatrial e na condução e refratariedade cardíaca Estudio prospectivo de las repercusiones de bajas dosis de remifentanil en la función sinoatrial en la conducción y refractariedad cardiaca Prospective study on the repercussions of low doses of remifentanil on sinoatrial function and in cardiac conduction and refractory period

    Directory of Open Access Journals (Sweden)

    Simone Soares Leite

    2007-10-01

    . CONCLUSÕES: O remifentanil alterou as variáveis eletrofisiológicas cardíacas, o que em doses maiores que as estudadas poderiam causar bradicardia sinusal, assistolia e distúrbios de condução.JUSTIFICATIVA Y OBJETIVOS: El remifentanil es un opioide con inicio y fin de acción rápidos, cuyo uso en procedimientos de corta duración se ha venido propagando en los últimos años. Entre los efectos colaterales descritos, hay relatos de bradicardia y asistolia. El objetivo de este estudio fue evaluar los efectos de este fármaco en la conducción y refractariedad cardíaca, en humanos. MÉTODO: Estudio prospectivo de 16 pacientes, entre 18 y 65 años, de ambos sexos, ASA I a III, que se sometieron a estudio electrofisiológico intra cardiaco electivo. Se excluyeron pacientes con enfermedades del nódulo sino-atrial y los portadores de bloqueos cardíacos graves. En el laboratorio de electrofisiologia, los pacientes fueron inicialmente sedados con midazolam (0,03 mg.kg-1, 5 minutos después (M0 se evaluó el grado de sedación e intensidad de dolor, presiones arteriales sistólica y diastólica, frecuencias cardíaca y respiratoria y saturación de oxígeno. El electrofisiologista evaluó las variables de conducción cardíaca (duración del QRS, intervalos AA, AH, HV y PA, el tiempo de recuperación del nódulo sino-atrial y las variables de refractariedad cardíaca (período refractario del atrio derecho, período refractario del ventrículo derecho y período refractario del nódulo atrio ventricular. Después de las medidas iniciales el remifentanil fue introducido (bolo de 0,5 µg.kg-1 + infusión de 0,05 µg.kg-1.min-1 y después de 20 minutos las mismas variables fueron evaluadas nuevamente (M1. RESULTADOS: Se observó disminución de las presiones sistólica y diastólica (p = 0.0001 entre M0 y M1, sin diferencia estadística significativa de la frecuencia respiratoria o de la saturación de oxígeno. Hubo aumento del intervalo atrio-His (p = 0,006 y del tiempo de

  13. Avaliação da cetamina racêmica e do isômero S(+, associados ou não a baixas doses de fentanil, na balneoterapia do grande queimado Evaluación de la cetamina racémica y del isómero S(+, asociados o no a bajas dosis de fentanil, en la balneoterapia del gran quemado Assessment of the use of racemic ketamine and its S(+ isomer, associated or not with low doses of fentanyl, in balneotherapy for major burn patients

    Directory of Open Access Journals (Sweden)

    Fernando Antônio de Freitas Cantinho

    2009-08-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: O cuidado da ferida do grande-queimado desencadeia estímulo doloroso muito intenso. Este estudo teve por objetivo avaliar a segurança e efetividade de diferentes combinações de fármacos na anestesia para balneoterapia. MÉTODO: Com a aprovação do Comitê de Ética, foram estudados 200 procedimentos de balneoterapia em 87 grandes queimados adultos. Em todos os casos foi empregado o midazolam. Foram utilizados frascos numerados da cetamina, não se conhecendo no momento do uso se era racêmica ou S(+. A cada manhã era sorteado se os procedimentos daquele dia seriam conduzidos com ou sem fentanil. Formaram-se quatro grupos: ISO/sf (isômero S(+ sem o fentanil, ISO/cf (isômero S(+ com o fentanil, RAC/sf (cetamina racêmica sem o fentanil e RAC/cf (cetamina racêmica com o fentanil. As doses iniciais propostas foram: midazolam 0,06 mg.kg-1, cetamina 1,0 a 1,1 mg.kg-1, fentanil 0,8 ¼g.kg-1; as doses adicionais eram administradas conforme necessário. RESULTADOS: Em apenas um caso houve lembrança de dor durante a balneoterapia. No grupo que recebeu a cetamina S(+, o acréscimo do fentanil não evidenciou vantagens; associado à forma racêmica, o fentanil reduziu a dose total e o número de bolus da cetamina. A extensão da superfície corporal queimada foi a principal determinante da intensidade de dor pós-procedimento. A menor intensidade de dor pós-procedimento foi o principal fator considerado pelo paciente para sua satisfação pela anestesia recebida. CONCLUSÕES: As quatro diferentes combinações de fármacos mostraram-se seguras e permitiram ausência de dor durante a balneoterapia. Características não ligadas diretamente aos anestésicos mostraram-se de maior importância na definição da dor pós-procedimento, que foi a principal característica considerada pelo grande queimado para definir sua satisfação com a anestesia recebida.JUSTIFICATIVA Y OBJETIVOS: El cuidado de la herida del gran quemado

  14. Use of neuronal networks in the modeling of the doses that receives the Cuban population by potassium-40 contained in their organism; Utilizacion de redes neuronales en la modelacion de las dosis que recibe la poblacion cubana por el potasio-40 contenido en su organismo

    Energy Technology Data Exchange (ETDEWEB)

    Zerquera, Juan Tomas; Prendes Alonso, Miguel; Lopez Bejerano, Gladys M.; Acosta Rodriguez, Nancy [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba)

    2001-07-01

    The potassium 40 constitutes the main source natural present in the organism that influences in the effective dose that people receive. With the objective of evaluating the contribution from this component to the doses received by the Cuban population, a study was developed in order to evaluate the doses for this cause. A representative sample was selected based on the distribution of Cuban population by sex and ages. The measurements were carried out in the Whole Body Counter of the Center for Radiation Protection and Hygiene. For the estimate of the doses an uniform distribution of potassium was assumed in the whole body and the methodology was used recommended by the ICRP. The values of annual effective dose varies between 93 and 209 mSv for the feminine sex and 102 and 212 mSv for the masculine sex. With the obtained values they were the adjustment coefficients for the functions dose-age for each one of the sexes. At the same time it was possible to model the estimate of the doses by means of a neural network that, trained with the obtained experimental data, it allows to estimate the due doses directly to the potassium 40 starting from the sex data, age, height and corporal weight. The effective dose mediates yearly for the public's members it was estimated in 149 {+-} 6 mSv, starting from the experimental data and the Cuban population's specific characteristics. (author)

  15. Dosimetric contribution of the organs of the I{sup 123}, I{sup 124} and I{sup 131} bio-kinetics in the dose estimate for euthyroid adults; Contribucion dosimetrica de los organos de la biocinetica de I{sup 123}, I{sup 124} y I{sup 131} en el estimado de dosis para adultos eutiroideos

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, A. M.; Rojas, A. R.; Castillo, D. C.; Idrogo, C. J.; Flores, U. H., E-mail: marvva@hotmail.com [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Ciudad Universitaria, Trujillo (Peru)

    2011-10-15

    Using the formalism MIRD and the representation of Crysty-Eckerman for the thyroid adult, is demonstrated that the dosimetric contributions of source organs of the biokinetics of the radiopharmaceuticals I{sup 123}, I{sup 124} and I{sup 131} (iodine) are not significant in the dose estimate. Therefore, the total absorbed dose by the gland is its auto-dose. Equally, the reported results do not present significant differences to the results found by the Marinelli scheme (auto-dose) for the thyroid represented by a sphere of 20 grams. (Author)

  16. Dose calibrators quality controls in Switzerland: six years of experience

    International Nuclear Information System (INIS)

    Bochud, F.; Spring, Ph.; Baechler, S.; Twerenbold, D.; Linder, R.; Leibundgut, F.

    2006-01-01

    In Switzerland, the legal use of open radioactive sources in nuclear medicine and the general requirements for quality controls are defined in a federal ordinance. The metrological traceability is guaranteed through a directive of the Swiss metrological office (M.E.T.A.S.) that requires each instrument to be monitored at least once a year through either a verification or an intercomparison. The verification is performed onsite by an accredited laboratory with a set of three gamma sources (Co-57, Cs-137 and Co-60) and - if applicable - a beta source (Sr-90/Y- 90). The intercomparison is made through conventional mail. A source of I-131 or Tc- 99 m is measured both in the nuclear medicine department and in an accredited laboratory. The maximum tolerated error is 10% for gamma sources and 20% for beta sources. This methodology guarantees that the instruments have a correct response for most of the energy range used in practice. Not all nuclides are systematically probed and manufacturers are ultimately responsible for the calibration factors. The precision of the measurements performed in Switzerland is satisfactory with only about 6% of the measurements out of the tolerances. This monitoring also allowed us to improve the skills of the personnel and update the park of instruments by getting rid of dose calibrators displaying old units. (authors)

  17. Dose calibrators quality controls in Switzerland: six years of experience

    Energy Technology Data Exchange (ETDEWEB)

    Bochud, F.; Spring, Ph.; Baechler, S. [Institut Universitaire de Radiophysique Appliquee, Lausanne (Switzerland); Twerenbold, D. [METAS, Lindenweg 50, Bern-Wabern (Switzerland); Linder, R. [Bundesamt fur Gesundheit, Abteilung Strahlenschutz, Bern (Switzerland); Leibundgut, F. [Raditec radiation and technology, Schoftland (Switzerland)

    2006-07-01

    In Switzerland, the legal use of open radioactive sources in nuclear medicine and the general requirements for quality controls are defined in a federal ordinance. The metrological traceability is guaranteed through a directive of the Swiss metrological office (M.E.T.A.S.) that requires each instrument to be monitored at least once a year through either a verification or an intercomparison. The verification is performed onsite by an accredited laboratory with a set of three gamma sources (Co-57, Cs-137 and Co-60) and - if applicable - a beta source (Sr-90/Y- 90). The intercomparison is made through conventional mail. A source of I-131 or Tc- 99 m is measured both in the nuclear medicine department and in an accredited laboratory. The maximum tolerated error is 10% for gamma sources and 20% for beta sources. This methodology guarantees that the instruments have a correct response for most of the energy range used in practice. Not all nuclides are systematically probed and manufacturers are ultimately responsible for the calibration factors. The precision of the measurements performed in Switzerland is satisfactory with only about 6% of the measurements out of the tolerances. This monitoring also allowed us to improve the skills of the personnel and update the park of instruments by getting rid of dose calibrators displaying old units. (authors)

  18. Measurement of dose speed absorbed in depth imparted by sources external secondary patterns of beta radiation. Part 1 Measurement of dose speed absorbed in the surface of soft fabric for isotopes of {sup 90}Sr/{sup 90}Y, {sup 147}Pm and {sup 204}TI; Medicion de rapidez de dosis absorbida en profundidad impartida por fuentes patrones secundarios de radiacion beta externos. Parte 1. Medicion de rapidez de dosis absorbida en la superficie de tejido blando para isotopos de {sup 90}Sr/{sup 90}Y, {sup 147}Pm y {sup 204}TI

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1993-01-15

    The dose speed was measured absorbed for depth zero, (superficial) in soft equivalent fabric, for the secondary pattern{sup s} four sources of beta radiation, (Nr. 86): {sup 90}Sr/{sup 90}Y, (1850 MBq and 74 MBq respectively); {sup 147}Pm, (518 MBq) and {sup 204}TI, (18.5 MBq). The measurement is carried out to different distances of source-detecting separation, (11.0, 30.0 and 50.0 cm for the source of 1850 MBq, 30.0 cm for that of 74 MBq; 11.00 cm for the source of {sup 147}Pmand to contact for all the sources); maintaining the radiation sheaf aligned the one axis of symmetry of the detector, ({alpha} 0 degrees). The detector employed was a extrapolation chambers of variable electrodes and electrode fixed collector, (30 mm of diameter). In accordance with the principle of Bragg-Gray the volume of the chambers is varied and they register the variations of the current of collected ionization, correcting until for a maximum of thirteen correction factors that take into account the deviation to the suppositions that it establishes this principle. The certain values of the speed of superficial absorbed dose are in the following intervals: {sup 90}Sr/{sup 90}Y, (1850 MBq, 0.0, 11.0, 30.0 and 50.0 cm): 43.164 mGy S-t, 0.544 mGy s-1 ,0.075 mGy s{sup -1} and 0.027 mGy s{sup -1}, respectively, with a Global Analysis of the order of 1.17%, 1.17%, 1.14% and 1.66%, K J; {sup 90}Sr / {sup 90}Y, (74 MBq, 0.0 and 30 cm): 1.536 mGy s{sup -1} and 0.002 mGy s{sup -1}, with Global Analysis of 1.19.0% and 5.22%, (K = 1) respectively, for the {sup 147}Pm, (0.0 and 11.0 in the interval of: 0.36 {mu}Gy s{sup -1} and 0.43 {mu}Gy s{sup -1}, with one Global Analysis of 1 .42% and 4.28%, (K = 1), respectively; and finally for the {sup 204}TI, (0.0 cm) in the interval of 0.10 {mu}Gy s{sup -1} with a Global Analysis of 1.27%. He calculates of the Global Analysis one carries out of agreement with those recommendations of the BIPM. In all the cases of source-detecting arrangement with

  19. Measurement of dose speed absorbed in depth imparted by sources external secondary patterns of beta radiation. Part 1 Measurement of dose speed absorbed in the surface of soft fabric for isotopes of {sup 90}Sr/{sup 90}Y, {sup 147}Pm and {sup 204}TI; Medicion de rapidez de dosis absorbida en profundidad impartida por fuentes patrones secundarios de radiacion beta externos. Parte 1. Medicion de rapidez de dosis absorbida en la superficie de tejido blando para isotopos de {sup 90}Sr/{sup 90}Y, {sup 147}Pm y {sup 204}TI

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1993-01-15

    The dose speed was measured absorbed for depth zero, (superficial) in soft equivalent fabric, for the secondary pattern{sup s} four sources of beta radiation, (Nr. 86): {sup 90}Sr/{sup 90}Y, (1850 MBq and 74 MBq respectively); {sup 147}Pm, (518 MBq) and {sup 204}TI, (18.5 MBq). The measurement is carried out to different distances of source-detecting separation, (11.0, 30.0 and 50.0 cm for the source of 1850 MBq, 30.0 cm for that of 74 MBq; 11.00 cm for the source of {sup 147}Pmand to contact for all the sources); maintaining the radiation sheaf aligned the one axis of symmetry of the detector, ({alpha} 0 degrees). The detector employed was a extrapolation chambers of variable electrodes and electrode fixed collector, (30 mm of diameter). In accordance with the principle of Bragg-Gray the volume of the chambers is varied and they register the variations of the current of collected ionization, correcting until for a maximum of thirteen correction factors that take into account the deviation to the suppositions that it establishes this principle. The certain values of the speed of superficial absorbed dose are in the following intervals: {sup 90}Sr/{sup 90}Y, (1850 MBq, 0.0, 11.0, 30.0 and 50.0 cm): 43.164 mGy S-t, 0.544 mGy s-1 ,0.075 mGy s{sup -1} and 0.027 mGy s{sup -1}, respectively, with a Global Analysis of the order of 1.17%, 1.17%, 1.14% and 1.66%, K J; {sup 90}Sr / {sup 90}Y, (74 MBq, 0.0 and 30 cm): 1.536 mGy s{sup -1} and 0.002 mGy s{sup -1}, with Global Analysis of 1.19.0% and 5.22%, (K = 1) respectively, for the {sup 147}Pm, (0.0 and 11.0 in the interval of: 0.36 {mu}Gy s{sup -1} and 0.43 {mu}Gy s{sup -1}, with one Global Analysis of 1 .42% and 4.28%, (K = 1), respectively; and finally for the {sup 204}TI, (0.0 cm) in the interval of 0.10 {mu}Gy s{sup -1} with a Global Analysis of 1.27%. He calculates of the Global Analysis one carries out of agreement with those recommendations of the BIPM. In all the cases of source-detecting arrangement with

  20. Dose in the uterus of a woman, with three months of pregnancy, due to the {sup 131} I accumulated in her thyroid gland; Dosis en el utero de una mujer, con tres meses de embarazo, debida la {sup 131} I acumulado en su glandula tiroides

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H R; Manzanares A, E; Hernandez D, V M; Arcos P, A [Unidades Academicas de Estudios Nucleares e Ingenieria Electrica, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2006-07-01

    In this study the absorbed dose by the uterus of a woman with three months of pregnancy to who was applied a dose of {sup 131} I that was accumulated in the thyroid gland is determined. The absorbed dose was obtained by means of Monte Carlo calculations developing a detailed three-dimensional model of the pregnant one, where they have been included most of the organs. The absorbed dose also was calculated by means of a simple procedure. To verify the calculated results it was carried out an experiment where was constructed a phantom of the neck, in this was included the thyroid with {sup 131} I and the exposure was measured at different distances of the neck; this was related with the dose. Of the Monte Carlo calculation is obtained that for each mCi of {sup 131} I that is retained in the mother's thyroid, the uterus absorbs a dose of 6.80 E(-11) Gy. When comparing the results, it was found that the simple calculation throws a result 29 times superior to that of the dose obtained by means of Monte Carlo. When applying a correction for the effect of the absorption of the gamma photons by the mother's body an absorbed dose in the uterus was obtained that is 0.16 times superior to the Monte Carlo calculation. Of the experimental phase it is verified that the values calculated by means of the simple method are equal to those experimentally measured. (Author)

  1. Feasibility of the use of PET/CT with {sup 1}8F-colina to increase the dose in traprostaticas lesions in radiotherapy of prostate cancer treatment; Viabilidad del uso de la PET/TC con {sup 1}8F-colina para aumentar la dosis en las lesiones intraprostaticas en tratamientos de radioterapia de cancer de prostata

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Hernandez, T.; Vicedo Gonzalez, A.; Pastor Peidro, J.; Lopez Torrecilla, J.; Rosello Ferrando, J.; Brualla Congalez, L.; Granero Cabanero, D.; Ferrer Rebolleda, J.; Sanchez Jurado, R.

    2013-07-01

    This paper explores the viability of an escalation of doses higher than 80 Gy in intraprostatics lesions, defined by 18FFluorocolina PET/CT, analyzing the variation of the dose in the organs of risk with respect to traditional planning with CT. (Author)

  2. Calculation of absorbed dose for skin contamination imparted by beta radiation through the VARSKIN modified code for 122 interesting isotopes for nuclear medicine, nuclear power plants and research; Calculo de dosis absorbida para contaminacion en piel impartida por radiacion beta mediante el codigo VARSKIN modificado para 122 isotopos de interes para medicina nuclear, plantas nucleares e investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T [Depto. de Metrologia, ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-07-01

    In this work the implementation of a modification of the VARSKIN code for calculation of absorbed dose for contamination in skin imparted by external radiation fields generated by Beta emitting is presented. The modification consists on the inclusion of 47 isotopes of interest even Nuclear Plants for the dose evaluation in skin generated by 'hot particles'. The approach for to add these isotopes is the correlation parameter F and the average energy of the Beta particle, with relationship to those 75 isotopes of the original code. The methodology of the dose calculation of the VARSKIN code is based on the interpolation, (and integration of the interest geometries: punctual or plane sources), of the distribution functions scaled doses in water for beta and electrons punctual sources, tabulated by Berger. Finally a brief discussion of the results for their interpretation and use with purposes of radiological protection (dose insurance in relation to the considered biological effects) is presented.

  3. Dosimetric evaluation in organs of the Tc{sup 99m}, I{sup 123} bio-kinetics to estimate dose in thyroid children 1 and 5 years; Evaluacion dosimetrica en organos de la biocinetica del Tc{sup 99m}, I{sup 123} para estimar dosis en tiroides ninos 1 y 5 anos

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, A. M.; Quispe, R.; Vasquez, D. J.; Rocha, M. D.; Morales, N. R.; Marin, R. K. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Ciudad Universitaria, Trujillo (Peru); Zelada, A. L., E-mail: marvva@hotmail.com [Universidad Cesar Vallejo, Grupo de Fisica Medica, Av. Larco s/n, Trujillo (Peru)

    2012-10-15

    Using the formalism MIRD and the representation of Cristy-Eckerman for the thyroid in children of 1 and 5 years, is demonstrated that the dosimetric contribution of the organs of I{sup 123} (iodure) bio-kinetics is not significant in the dose estimate. The total dose absorbed by the gland is its auto dose. The dosimetric contribution of the organs source of the Tc{sup 99m} (pertechnetate) bio-kinetics in the gland is significant in the dose estimate like to be ignored. The reported results for the iodure are not significantly different to the found for the Marinelli scheme (auto-dose) for thyroid represented by a sphere of 1,78 and 3,45 grams. (Author)

  4. Control of absorbed dose in radiotherapy with 60 Co units

    International Nuclear Information System (INIS)

    Penchev, V.; Constantinov, B.; Buchakliev, Z.

    2000-01-01

    A Network for External Quality Audit has been developed and established in Bulgaria by the Secondary Standard Dosimetry Laboratory (SSDL) - Sofia. The results prove the usefulness of the TL Postal Dose programme in helping Bulgarian radiotherapy departments improve and maintain the consistency of patient doses in clinically acceptable level. The participation of the SSDL-Sofia in the IAEA Quality Audit Programme confirms the quite satisfactory accuracy of the therapy level dose measurements and determination achieved. The role of the SSDL is critical in providing traceable calibration to hospitals

  5. Monte Carlo simulation of the dose distribution around the {sup 125}I model 6711 seed as function of radius of the silver cylinder using the Penelope code; Simulacion por el Metodo de Monte Carlo de la distribucion de dosis alrededor de la semilla de {sup 125}I modelo 6711 en funcion del radio del cilindro de plata usando el codigo Penelope

    Energy Technology Data Exchange (ETDEWEB)

    Nerio, U. [Universidad de Cordoba, Monteria (Colombia); Instituto Nacional de Cancerologia, Bogota (Colombia); Chica, L. [Universidad Nacional de Colombia, Bogota (Colombia); Paul, A. [Universite de la Mediterranee, Marseille (France)

    2004-07-01

    The Monte Carlo method is applied to find the dose rates distribution in tissue around {sup 125} I seeds model 6711 as a function of the silver cylinder radius, R{sub sc} (0.017, 0.021, 0.025, 0.029 and 0.033) cm are used as radius values. It is found here that the dose rate at any point within the tissue decreases as R{sub sc} increases. The relative difference of dose rate that produced by the standard R{sub sc} seed, is less than 5%, for seeds with Rsc between 0.017 and 0.033 cm. (author)

  6. Controlled platform for the radiation dose data measured in Radiation controlled area of KOMAC

    International Nuclear Information System (INIS)

    Park, Sung Kyun; Min, Yi Sub; Park, Jeong Min; Cho, Yong Sub

    2016-01-01

    Korea multi-purpose accelerator complex (KOMAC), the branch institute of Korea atomic energy research institute (KAERI), is a multi-user facility to provide a high-intensity proton beam with the energy from 20 MeV to the 100 MeV. This proton beam is accelerated via the proton linear accelerator that is comprised of a 50-keV injector, 3-MeV radio frequency quadrupole (RFQ), and 100-MeV drift tube linac (DTL). The KOMAC site is classified into General public area and Radiation controlled area, according to the dose rate of 0.25 μSv/h. The system for the data made in Radiation controlled area should have the database to save and the data in the database could be expressed on the monitor in the any form which user wants. The control platform to satisfy these conditions will be made on the basis of the Qt program and MYSQL program. The place with the maximum average values about the alpha and beta detected is the entrance of Radiation controlled area. However, their values are very small in comparison to the criteria to decide the contamination area in KOMAC. That is, KOMAC is safe from the radioactive contamination. The reason why the radiation dose value is twice the background value in Klystron gallery is the klystron to generate the radiation. However, actually the klystron gallery is controlled by the control room when the proton beam is accelerated

  7. Controlled platform for the radiation dose data measured in Radiation controlled area of KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Kyun; Min, Yi Sub; Park, Jeong Min; Cho, Yong Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Korea multi-purpose accelerator complex (KOMAC), the branch institute of Korea atomic energy research institute (KAERI), is a multi-user facility to provide a high-intensity proton beam with the energy from 20 MeV to the 100 MeV. This proton beam is accelerated via the proton linear accelerator that is comprised of a 50-keV injector, 3-MeV radio frequency quadrupole (RFQ), and 100-MeV drift tube linac (DTL). The KOMAC site is classified into General public area and Radiation controlled area, according to the dose rate of 0.25 μSv/h. The system for the data made in Radiation controlled area should have the database to save and the data in the database could be expressed on the monitor in the any form which user wants. The control platform to satisfy these conditions will be made on the basis of the Qt program and MYSQL program. The place with the maximum average values about the alpha and beta detected is the entrance of Radiation controlled area. However, their values are very small in comparison to the criteria to decide the contamination area in KOMAC. That is, KOMAC is safe from the radioactive contamination. The reason why the radiation dose value is twice the background value in Klystron gallery is the klystron to generate the radiation. However, actually the klystron gallery is controlled by the control room when the proton beam is accelerated.

  8. Comparison in the calculation of committed effective dose using the ICRP 30 and ICRP 60 models for a repeated incorporation by inhalation of I-125; Comparacion en el calculo de la dosis efectiva comprometida usando los modelos del ICRP 30 y del ICRP 60 para una incorporacion repetida por inhalacion de I-125

    Energy Technology Data Exchange (ETDEWEB)

    Carreno P, A.L.; Cortes C, A. [CNSNS, Dr. Barragan 779, Col. Narvarte, Mexico D.F. (Mexico); Alonso V, G.; Serrano P, F. [IPN, Edificio de Fisica Avanzada Zacatenco, 07300 Mexico D.F. (Mexico)

    2005-07-01

    Presently work, a comparison in the calculation of committed effective dose using the models of the ICRP 30 and those of the ICRP 60 for the analysis of internal dose due to repeated incorporation of I-125 is shown. The estimations of incorporated activity are obtained starting from the proportionate data for an exercise of inter comparison, with which it should be determined the internal dose later on. For to estimate the initial activity incorporated by repeated dose was assumed that this it was given through of multiple individual incorporations which happened in the middle points of the monitoring periods. The results using the models of the ICRP 30 and of the ICRP 60 are compared and the causes of the differences are analyzed. (Author)

  9. Calculation of dose absorbed for the verification of the calibration curves UH-Density electronic relative obtained with various mannequins; Calculo de dosis absorbida para la verificacion de las curvas de calibracion UH-Densidad electronica relativa obtenidas con distintos maniquies

    Energy Technology Data Exchange (ETDEWEB)

    Perez Alvarez, M. E.; Sena Espinel, E. de; Delgado Aparicio, J. M.; Martin Rincon, C.; Garcia Repiso, S.; Ramos Pacho, J. A.; Verde Velasco, J. M.; Gomez Gonzalez, N.; Cons Perez, N.; Saez Beltran, M.

    2013-07-01

    In order to discern with what calibration curve is obtained a more accurate dosimetry distribution, dose measurements are carried out on the treatment unit and the values found are evaluated. (Author)

  10. Dose in the uterus of a woman, with three months of pregnancy, due to the {sup 131} I accumulated in her thyroid gland; Dosis en el utero de una mujer, con tres meses de embarazo, debida la {sup 131} I acumulado en su glandula tiroides

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Arcos P, A. [Unidades Academicas de Estudios Nucleares e Ingenieria Electrica, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)]. e-mail: fermineutron@yahoo.com

    2006-07-01

    In this study the absorbed dose by the uterus of a woman with three months of pregnancy to who was applied a dose of {sup 131} I that was accumulated in the thyroid gland is determined. The absorbed dose was obtained by means of Monte Carlo calculations developing a detailed three-dimensional model of the pregnant one, where they have been included most of the organs. The absorbed dose also was calculated by means of a simple procedure. To verify the calculated results it was carried out an experiment where was constructed a phantom of the neck, in this was included the thyroid with {sup 131} I and the exposure was measured at different distances of the neck; this was related with the dose. Of the Monte Carlo calculation is obtained that for each mCi of {sup 131} I that is retained in the mother's thyroid, the uterus absorbs a dose of 6.80 E(-11) Gy. When comparing the results, it was found that the simple calculation throws a result 29 times superior to that of the dose obtained by means of Monte Carlo. When applying a correction for the effect of the absorption of the gamma photons by the mother's body an absorbed dose in the uterus was obtained that is 0.16 times superior to the Monte Carlo calculation. Of the experimental phase it is verified that the values calculated by means of the simple method are equal to those experimentally measured. (Author)

  11. Determination of the absorbed dose rate to a person exposed to a spent source of {sup 60}Co for radiotherapy; Determinacion de la rapidez de dosis absorbida a una persona expuesta a una fuente gastada de {sup 60}Co para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia M, T.; Angeles C, A.; Benitez, J. A.; Ruiz C, M. A., E-mail: teodoro.garcia@inin.gob.mx [ININ, Departamento de Proteccion Radiologica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    In this work the analysis of absorbed dose rate to a person in made due to the exposure to a spent source of {sup 60}Co of radiotherapy, which has been removed from its shielding clandestinely to sell the shielding as scrap. During the removal of the source of their shielding the people were necessarily exposed to the field of gamma radiation. The activity of the source is considered to be 2595 Ci at the exposure time and to determine the rate of absorbed dose to different organs and the velocity of effective absorbed dose to which the person (s) who manipulated the source of {sup 60}Co were considered three plausible scenarios of manipulation of the source , through modeling with MCNP5. For the execution of the scenarios and the determination of the absorbed doses, two different phantoms are considered. The results obtained for each scenario show that the dose rates to which the people who manipulated the source without the shielding were exposed are extremely high, and in short time the lethal dose is reached. (Author)

  12. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  13. Evaluation of the absorbed dose during studies of the renal function due to I{sup 123} / I{sup 131} (hippuran) and In{sup 111} (DTPA); Evaluacion de la dosis absorbida durante estudios de la funcion renal debido a I{sup 123} / I{sup 131} (hippuran) e In{sup 111} (DPTA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.; Castillo, C.; Sarachaga, R.; Rojas, R.; Zelada, L.; Melendez, J.; Gomez, M. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Ciudad Universitaria, Trujillo (Peru); Diaz, E., E-mail: marvva@hotmail.com [Universidade Federal do Rio Grande do Sul, Av. Paulo Gamma 110, Bairro Farropilhas, Porto Alegre, RS 90040-060 (Brazil)

    2014-08-15

    Using the methodology MIRD and representation Cristy-Eckerman for kidneys, bladder, and whole body as organs of the bio-kinetics of I{sup 123} / I{sup 131} (hippuran) and the In{sup 111} (D PTA), the absorbed dose for studies of the renal function of adults due to the I{sup 123} is 0,0071 mGy/MBq where 88.16% corresponds to its auto-dose and 11,96% to the organs of their bio-kinetics; while for the I{sup 131} their dose is 0,032 mGy/MBq where 95,03% corresponds to its auto-dose and 4,97% to the organs of their bio-kinetics. For the In{sup 111} their dose is 0,0168 mGy/MBq where 71,68% corresponds to their auto-dose and 28,32% to the organs of their bio-kinetics. In all the cases the dosimetric contributions of the organs of the bio-kinetics (whole body and urinary bladder) are very significant, and this fundamentally is due to the photons of the whole body. (Author)

  14. El Retículo Endoplasmático Liso en Hepatocitos Estimulados con Distintas Dosis de Láser Infrarrojo

    OpenAIRE

    Cornejo, R; Garrido, O; Bustamante, C; Muñoz, M

    2014-01-01

    Veinticuatro ratas hembras Sprague Dawley de 4 meses de vida con peso aproximado de 250 g, fueron divididas en cuatro grupos (A, B, C y D), donde el grupo A (control) no recibió estimulación infrarroja, B se irradió con láser infrarrojo 4 J/cm², C con dosis de 8 J/cm² y D con 16 J/cm². La estimulación infrarroja se realizó diariamente, por 15 días ininterrumpidos. Las ratas fueron sacrificadas y se extrajeron muestras tanto de hígado normal (control) como estimulado con las distintas dosis in...

  15. Analysis and planning of dose-finding studies with active control

    International Nuclear Information System (INIS)

    Helms, Hans-Joachim

    2014-01-01

    In the clinical development of radiopharmaceuticals the dose finding plays an important role. The contribution is focused on the evaluation and planning of dose finding studies with active control. It is of primary interest to find the lowest dose that yields the same efficacy as the active control. Besides the target dose confidence intervals are of importance to describe the quality of the target dose estimation. The calculation of case numbers and the determination of the dose steps to be studied are challenging under practical conditions. The contribution covers the demonstration of the statistical model the parameter estimation and the asymptotic properties based on maximum likelihood theory, the spline-based evaluation of nonlinear dose finding studies with active control and the planning of design and number of cases.

  16. THE RESULTS OF INDIVIDUAL DOSE CONTROL OF HEALTH INSTITUTIONS STAFF

    Directory of Open Access Journals (Sweden)

    E. N. Shleenkova

    2014-01-01

    Full Text Available The  work  provides  comparative  assessment  of  the  levels  of  occupational  exposure  of  Saint-Petersburg health institutions staff. The analysis was carried out of the 891 individual doses measurement results which have  being  obtained  during  5  years  investigations  (2009-2013.  The  comparing  of  the  average  annual effective doses was carried out for 4 groups of medical specialists: x-ray laboratory assistant, radiotherapist, radiographer of dental clinics and X-ray surgery staff (surgeons, anesthesiologists and surgical nurses who are working close to irradiation source. It is shown that the annual effective dose average value is about 0.5 mSv for the first three groups of medical specialists. The same value for X-ray surgery staff is 1.6 mSv. Individual  annual  exposure  doses  have  not  exceeded  the  main  dose  limits  required  by  Radiation  Safety Standard 99/2009. The issues are considered of the estimation exactness of the effective dose basing on the results of individual dose equivalent measurement. 

  17. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  18. Embarazo cornual: tratamiento médico con dosis única de metotrexato

    OpenAIRE

    Ricci A,Paolo; Troncoso J,José Luis; Avilés L,Guillermo; Avilés D,Raimundo

    2013-01-01

    Presentamos un caso de embarazo cornual o intersticial diagnosticado en forma precoz a través de ecografía transvaginal, tratado exitosamente, en forma conservadora, con dosis única sistémica de metotrexato.

  19. Influence of bismuth shielding use in the dose CT and the imaging quality in standard brain protocol; Influencia del uso de un protector ocular de bismuto sobre el indice de dosis TC y el ruido de la imagen en un protocolo de craneo estandar

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Carnoma, G.; Urena Llinares, A.; Santos Rubio, A.; Haro Madero, G.; Herrador Cordoba, M.

    2006-07-01

    The purpose of this work is to evaluate the reduction of lens doses, CT dose index (CTDI) and image quality when bismuth shielding is used. Dose indexes nCDTIs,p, w were measured for a head phantom (d=16 cm) in three situations: first, without shielding, second, shielded with bismuth over the phantom surface and, last, with 2 cm between both. Four regions of interest were selected, two including the theoretical eyes position and the others 4-6 cm below them. Noise and grey level in Housfield units were also measured in all geometries. A bismuth shielding in contact or 2 cm above surface provides a dose reduction of 36% y 29% respectively. In the first case an importation of image quality appears, increasing a 55% the Housfield units in the superficial regions of interest and a growth of noise 6 times greater. Bismuth protection provides an important reduction in lens dose., in the case of dire ct incidence radiation beam. (Author)

  20. Dosimetry by means of external dose rate measurements in patients undergoing 131I thyroid cancer theraphy; Dosimetria de pacientes con cancer diferenciado de tiroides en tratamiento de terapia metabolica con 131I a partir de medidas de tasa de dosis externa

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, M.A.; Ferrer, N.; Cordoba, D.; Alonso, L.; Sastre, J.M.; Arranz, L.

    2010-07-01

    Dosimetry in patients treated with radiopharmaceuticals needs to be carried out for each individual treatment. No standardized procedure is currently available. In our study, the dosimetry for each individual treatment has been calculated using the dose protocol of the Sociedad Espanola de Fisica Medica for the treatment of thyroid cancer with 131I. This protocol is currently under review, since it proposes a procedure which only uses the daily external dose rate measurements during the patient hospital stay and an external dose rate measurement performed 7-9 days after the activity administration. The results obtained seem to be consistent with those found by other authors following different procedures. Moreover, this protocol has proved to be very useful to verify the values of doses established for red marrow are not exceeded. The maximum activity that can be administered in later treatments could also be assessed with this procedure. Additionally, the activity in urine, which cannot be measured directly, was determined. The potential dose which any patients relative or any person staying close to the patient might receive during the treatment was determined as well. These results make it possible to establish more realistic criteria regarding radiation protection. (Author).

  1. Evaluation of the potential inhibitor of Ix (Pp-Ix) protoporphyrin of the genetic damage induced by gamma rays administered to different dose reasons in Drosophila melanogaster; Evaluacion del potencial inhibidor de la protoporfirina IX (PP-IX) del dano genetico inducido por rayos gama administrados a diferentes razones de dosis en Drosophila melanogaster

    Energy Technology Data Exchange (ETDEWEB)

    Flores A, J. A.

    2016-10-01

    Ionizing radiation can damage in DNA directly or indirectly by free radicals (Rl), characterized by unstable and highly reactive. To avoid damage by Rl the cell has endogenous antioxidants such as Sod, Cat, GSH or exogenous as some vitamins, but if with these mechanisms does not reach the cell homeostasis, the consequence may be the generation of chronic-disease degenerative such as cancer. This study was conducted in order to test the inhibitory role of Rl protoporphyrin Ix (Pp-Ix), induced by 20 Gy of gamma rays administered at different dose ratios using the assay of somatic mutation and recombination in the Drosophila wing. The results indicated that 20 Gy delivered at a rate of low dose (6.659 Gy/h), caused elevated frequencies of genetic damage (p <0.001), compared with those that induced a high dose reason (1111.42 Gy/h) in larvae of 48 h old. The difference is probably due to an indirect damage by Rl; when this hypothesis was approved with the possible inhibitor role of Pp-Ix (0.69 m M), damage was increased with the two reasons of tested doses. This result may be due to: 1) the Pp-Ix is not a good inhibitor of Rl, 2) the difference in the frequency of mutation found with both dose reasons, not due to Rl so that this compound did not reduce the genetic damage, and 3) that Pp-Ix acts as pro oxidant. (Author)

  2. Balance energético y capacidad gluconeogénica de vacas lecheras a pastoreo tratadas con una baja dosis de somatotropina recombinante bovina en el período de transición

    OpenAIRE

    JL Sánchez; CA Wagemann; C Strieder-Barboza; M Noro

    2014-01-01

    El objetivo del estudio fue determinar el efecto de la dosis baja (250 mg/vaca) de somatotropina recombinante bovina (rbST) en vacas lecheras a pastoreo en período de transición sobre los indicadores energético-proteínicos y capacidad gluconeogénica. Se realizaron 3 ensayos: Preparto, se utilizaron 10 vacas preparto, grupo bST (n = 5): dosis única de rbST el día (d) 26 preparto, y control (n = 5); se obtuvieron muestras de sangre y se registró la condición corporal (CC) cada 3 d desde el 26 d...

  3. Radiation apparatus with distance mapper for dose control

    International Nuclear Information System (INIS)

    Saunders, A.M.

    1990-01-01

    The patent describes apparatus for delivering a radiation dose. It comprises: radiation source means for producing a beam of ionizing gamma ray or x-ray radiation directed so as to deliver a dose of the radiation to an area of a target surface, a light source emitting a light beam in a direction transverse to the direction of the ionizing radiation beam, a photodetector, positioned to receive light scattered from the target surface, means for scanning the light beam over the area of the target surface, means for forming a three-dimensional surface profile map of the area of the target surface without movement of the radiation source means or the light source, and means responsive to the surface profile map for adjusting the dose of radiation from the radiation source over the area of the target surface, so that the radiation source means and the light source may be operated simultaneously

  4. An overview of zinc addition for BWR dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Marble, W.J. [GE Nuclear Energy, San Jose, CA (United States)

    1995-03-01

    This paper presents an overview of the BWRs employing feedwater zinc addition to reduce primary system dose rates. It identifies which BWRs are using zinc addition and reviews the mechanical injection and passive addition hardware currently being employed. The impact that zinc has on plant chemistry, including the factor of two to four reduction in reactor water Co-60 concentrations, is discussed. Dose rate results, showing the benefits of implementing zinc on either fresh piping surfaces or on pipes with existing films are reviewed. The advantages of using zinc that is isotopically enhanced by the depletion of the Zn-64 precursor to Zn-65 are identified.

  5. Calculation of the absorbed dose for contamination in skin imparted by beta radiation through the Varskin code modified for 122 isotopes of interest for nuclear medicine, nuclear plants and research; Calculo de dosis absorbida para contaminacion en piel impartida por radiacion beta mediante el codigo Varskin modificado para 122 isotopos de interes para medicina nuclear, plantas nucleares e investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T

    1992-06-15

    In this work the implementation of a modification of the Varskin code for calculation of absorbed dose by contamination in skin imparted by external radiation fields generated by beta emitting is presented. The necessary data for the execution of the code are: isotope, dose depth, isotope activity, geometry type, source radio and time of integration of the isotope, being able to execute combinations of up to five radionuclides. This program it was implemented in Fortran 5 by means of the FFSKIN source program and the executable one in binary language BFFSKIN being the maximum execution time of 5 minutes. (Author)

  6. Ambient dose equivalent and personal points due to photoneutrons outside a facility that houses a linear accelerator of 18 MV varian; Equivalente de dosis ambiental y personal debida a fotoneutrones en puntos externos a una instalacion que alberga un acelerador lineal varian de 18 MV

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, S. A.; Barquero, R.; Gomez-Ros, J. M.; Lallena, A. M.; Ponzano, P. E.

    2011-07-01

    The use of linear accelerators (linacs) with energies above 10 MV radiotherapy treatments RT and IMRT, can improve the distribution of the absorbed dose in the treated area, increasing the effectiveness of radiation treatments. However and as shown in the scientific literature, the production of photoneutrons for energies above 10 MeV can contribute to exposure of both patient and occupationally exposed workers and the public in the vicinity of the installation. It is therefore necessary to determine the value of ambient dose equivalent and staff both inside and outside the facilities that house these accelerators, especially for energies of 15 and 18 MV.

  7. Dosimetric contribution of organs of biokinetics of {sup 99m}Tc and {sup 123}I to estimate radiation doses in thyroids of children of 1 and 5 years; Contribucion dosimetrica de organos de la biocinetica del {sup 99m}Tc y {sup 123}I para estimar dosis en tiroides de ninos de 1 y 5 anos

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.V.; Castillo, C.E.; Abanto, D.M.; Rocha, D.; Garcia, W.H.; Marin, K., E-mail: marvva@hotmail.com [Universidad Nacional de Trujillo (UNT), Trujillo (Peru); Quispe, R. [Centro de Ciencias Aplicadas y Desarrollo Tecnologico, UNAM, Mexico (Mexico)

    2015-07-01

    The absorbed doses by thyroids during uptake studies through biokinetics of radiopharmaceuticals containing {sup 123}I (iodine) or {sup 99m}Tc (pertechnetate) are estimated. Using the MIRD scheme and the representation of Cristy-Eckerman for thyroids in children of 1 and 5 years, the objective of the study was to determine whether the dosimetric biokinetic contributions of the organs of {sup 123}I (iodide) and {sup 99m}Tc (pertechnetate) biokinetic are significant in the estimated of the absorbed dose for thyroid uptake studies.

  8. Dose-response relationship of induction kinetics of In vivo DNA damage and repair in mouse leukocytes exposed to gamma radiation; Relacion dosis-respuesta de la cinetica de induccion de dano y reparacion del ADN In vivo en leucocitos de raton expuestos a radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M.T.; Morales, R.P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Investigacion Basica, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The Unicellular electrophoresis in gel technique is a useful tool in the determination of simple ruptures and labile sites to the alkali in DNA of eucariontes cells. The determination of the induction kinetics of damage and repair of DNA can give more information. The objective of this work was to determine whether the analysis of the area under the damage/repair induction kinetics curve in comets percent or the comets frequency in the two peaks of maximum induction is adequate for determining the dose-response relationship. The mice were exposed at the doses of 0.5, 1.0, 2.0 Gy. (Author)

  9. Blind method of clustering for the evaluation of the dose received by personnel in two methods of administration of radiopharmaceuticals; Metodo ciego de clusterizacion para la evaluacion de la dosis recibida por el personal en dos metodos de administracion de radioformacos

    Energy Technology Data Exchange (ETDEWEB)

    VerdeVelasco, J. M.; Gonzalez Gonzalez, M.; Montes Fuentes, C.; Verde Velasco, J.; Gonzalez Blanco, F. J.; Ramos Pacho, J. A.

    2013-07-01

    The difficulty for the injection of drugs marked with radioactive isotopes while syringe is located within the lead protector does that in many cases staff do it chooses to use the syringe outside the lead protector, increasing therefore the dose of radiation received. In our service raises the possibility of using a different methodology, channeling a pathway through a catheter, which allows administer, in all cases, with the syringe within the lead guard. We will check if significant differences can be seen both in the dose absorbed by the staff as in the time it takes to perform the administration of the drug using the method proposed compared injection without guard. (Author)

  10. Dosis óptima de irradiación gamma con Co60 para inducción de mutagénesis en pastos

    Directory of Open Access Journals (Sweden)

    Alan Álvarez-Holguín

    2017-01-01

    Full Text Available La dosis letal (DL 50 y reducción media del crecimiento (RC 50 son parámetros utilizados para seleccionar dosis de irradiación adecuadas e inducir mutaciones para realizar mejoramiento genético vegetal. El objetivo fue determinar la DL 50 y RC 50 para conocer la dosis ó p tima de irradiación c on Co 60 en semilla de pasto llorón, buffel, banderita y navajita. Se evaluaron seis dosis de irradiación con Co 60 en semilla : 100, 200, 300, 450, 600 y 900 Gray (Gy y un tratamiento control (T - 0, sin irradiación. Las variables evaluadas fueron : porcentaj e de germinación (%GE, índice de velocidad de germinación (IVG, longitud de plúmula (LP y longitud de radícula (LR. Se realizó análisis de regresión y comparación de medias con la prueba de Dunnett. Mediante la ecuación de regresión se estimó la DL 50 p ara el %GE, así como RC 50 para el resto de las variables. La DL 50 se ponderó con 55%, mientras que la RC 50 se ponderó en 15% para cada una de las tres variables restantes. En general, los valores de las variables disminuyeron (P<0.05 conforme se incremen tó la dosis de irradiación, lo cual permitió determinar la DL 50 y RC 50 para cada especie. La media ponderada se obtuvo a los 628 Gy, 712 Gy, 698 Gy y 411 Gy para pasto llorón, buffel, banderita y navajita, respectivamente. Se recomiendan las dosis plantead as en este estudio, ya que esto permitirá plantear las bases para realizar mejoramiento genético a través de mutagénesis con irradiación gamma en los pastos evaluados.

  11. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  12. Differences in absorbed doses at risk organs and target tumoral of planning(PTV) in lung treatments using two algorithms of different calculations; Diferencias en las dosis absorbidas en organos de riesgo y volumen tumoral de planificacion (PTV) en tratamientos de pulmon usando dos algoritmos de calculo diferentes: pencil beam y collpased cone

    Energy Technology Data Exchange (ETDEWEB)

    Uruena Llinares, A.; Santos Rubio, A.; Luis Simon, F. J.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2006-07-01

    The objective of this paper is to compare, in thirty treatments for lung cancer,the absorbed doses at risk organs and target volumes obtained between the two used algorithms of calculation of our treatment planning system Oncentra Masterplan, that is, Pencil Beams vs Collapsed Cone. For it we use a set of measured indicators (D1 and D99 of tumor volume, V20 of lung, homogeneity index defined as (D5-D95)/D prescribed, and others). Analysing the dta, making a descriptor analysis of the results, and applying the non parametric test of the ranks with sign of Wilcoxon we find that the use of Pencil Beam algorithm underestimates the dose in the zone of the PTV including regions of low density as well as the values of maximum dose in spine cord. So, we conclude that in those treatments in which the spine dose is near the maximum permissible limit or those in which the PTV it includes a zone with pulmonary tissue must be used the Collapse Cone algorithm systematically and in any case an analysis must become to choose between time and precision in the calculation for both algorithms. (Authors)

  13. Influência de variáveis do treinamento contra-resistência sobre a força muscular de idosos: uma revisão sistemática com ênfase nas relações dose-resposta Influencia de las variables de entrenamiento contra-resistencia sobre la fuerza muscular de ancianos: una revisión sistemática con énfasis en las relaciones dosis-respuesta Influence of counter-resistance training variables on elderly muscular strength: a systematic review with emphasis on dose/response relationships

    Directory of Open Access Journals (Sweden)

    Nádia Lima da Silva

    2007-02-01

    Full Text Available A força muscular é considerada componente importante de programas de exercícios físicos. Os benefícios desse tipo de treinamento dependem da combinação do número de repetições, séries, sobrecarga, seqüência e intervalos entre as séries e exercícios. No entanto, não se tem ainda muito clara qual a melhor combinação dessas variáveis para uma ótima relação dose-resposta em pessoas idosas. O objetivo do estudo foi analisar as pesquisas sobre treinamento de força para idosos, por meio de revisão sistemática, com o propósito de identificar tendências comuns em termos de efeitos do treinamento provocados pela manipulação dessas variáveis. Após definição de critérios de inclusão, foram selecionados 22 estudos, agrupados por similaridade de tratamento (número de séries, freqüência semanal, intensidade, intervalos e ordem dos exercícios. Técnicas de estatística descritiva auxiliaram na determinação de possíveis tendências nas relações dose-resposta. Uma vez identificadas, essas tendências foram analisadas qualitativamente. De todas as variáveis revisadas, somente para a intensidade da sobrecarga foram encontradas evidências permitindo afirmar que cargas maiores seriam mais eficazes para induzir aumento de força nessa faixa etária. Quanto às demais variáveis, os resultados disponíveis na literatura não dão respaldo para inferências seguras quanto ao melhor delineamento de programas de treinamento que aliem, ao mesmo tempo, efetividade e segurança. Recomenda-se, então, que estudos sejam realizados para comparar experimentalmente os efeitos da manipulação dessas variáveis sobre a força muscular de idosos.La fuerza muscular es considerada componente importante de programas de ejercicios físicos. Los beneficios de ese tipo de entrenamiento dependen de la combinación del número de repeticiones, series, sobrecarga, secuencia e intervalos entre las series y ejercicios. A pesar de esto, no se

  14. Estimation of the contribution by neutrons to the equivalent dose for exposed occupationally personnel and people in medical use facilities: X rays of equal or superior energy to 10 MV; Estimacion de la contribucion por neutrones a la dosis equivalente para personal ocupacionalmente expuesto y publico en instalaciones de uso medico: rayos X de energia igual y/o superior a 10 MV

    Energy Technology Data Exchange (ETDEWEB)

    Ortega J, R.; Reyes S, M. A. [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan 779, Col. Narvarte, 03020 Mexico D. F. (Mexico); Moranchel y R, M., E-mail: rojimenez@cnsns.gob.mx [IPN, Escuela Superior de Fisica y Matematicas, Departamento de Ingenieria Nuclear, Av. Instituto Politecnico Nacional s/n, U. P. Adolfo Lopez Mateos, Edif. 9, Col. San Pedro Zacatenco, 07738 Mexico D. F. (Mexico)

    2013-10-15

    In Mexico the use of electron accelerators for treating cancerous tumors had grown enormously in the last decade. When the treatments are carried out with X-ray beam energy below 10 MV the design of the shielding of the radioactive facility is determined by analyzing the interaction of X-rays, which have a direct impact and dispersion, with materials of the facility. However, when it makes use of X-ray beam energy equal to or greater than 10 MV the neutrons presence is imminent due to their generation by the interaction of the primary beam X-ray with materials head of the accelerator and of the table of treatment, mainly. In these cases, the design and calculation of shielding considers the generation of high-energy neutrons which contribute the equivalent dose that public and occupationally staff exposed (POE) will receive in the areas surrounding the facility radioactive. However, very few measurements have been performed to determine the actual contribution to the neutron dose equivalent received by POE and public during working hours. This paper presents and estimate of the actual contribution of the neutron dose equivalent received by public and POE facilities in various radioactive medical use, considering many factors. To this end, measurements were made of the equivalent dose by using a neutron monitor in areas surrounding different radioactive installations (of Mexico) which used electron accelerators medical use during treatment with X-ray beam energy equal to or greater than 10 MV. The results are presented after a statistical analysis of a wide range of measures in order to estimate more reliability real contribution of the neutron dose equivalent for POE and the public. (author)

  15. Estimation of the contribution of neutrons to the equivalent dose for personnel occupationally exposed and public in medical facilities: X-ray with energy equal or greater than 10MV; Estimacion de la contribucion por neutrones a la dosis equivalente para personal ocupacionalmente expuesto y publico en instalaciones de uso medico: rayos X de energia igual y/o superior a 10MV

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Alfonso Mayer; Jimenez, Roberto Ortega; Sanchez, Mario A. Reyes, E-mail: amgesfm@hotmail.com, E-mail: rojimenez@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS), Mexico, D.F. (Mexico); Moranchel y Mejia, Mario, E-mail: mmoranchel@ipn.mx [Instituto Politecnico Nacional (ESFM/IPN), Mexico, D.F. (Mexico). Escuela Superior de Fisica y Matematicas. Departamento de lngenieria Nuclear

    2013-07-01

    In Mexico the use of electron accelerators for treating cancerous tumors had grown enormously in the last decade. When the treatments are carried out with X-ray beam energy below 10 MV the design of the shielding of the radioactive facility is determined by analyzing the interaction of X-rays, which have a direct impact and dispersion, with materials of the facility. However, when it makes use of X-ray beam energy equal to or greater than 10 MV the neutrons presence is imminent due to their generation by the interaction of the primary beam X-ray with materials head of the accelerator and of the table of treatment, mainly. In these cases, the design and calculation of shielding considers the generation of high-energy neutrons which contribute the equivalent dose that public and Occupationally Staff Exposed (POE) will receive in the areas surrounding the facility radioactive. However, very few measurements have been performed to determine the actual contribution to the neutron dose equivalent received by POE and public during working hours. This paper presents an estimate of the actual contribution of the neutron dose equivalent received by public and POE facilities in various radioactive medical use, considering many factors. To this end, measurements were made of the equivalent dose by using a neutron monitor in areas surrounding different radioactive installations (of Mexico) which used electron accelerators medical use during treatment with X-ray beam energy equal to or greater than 10 MV. The results are presented after a statistical analysis of a wide range of measures in order to estimate more reliability real contribution of the neutron dose equivalent for POE and the public. (author)

  16. The effects of radiotherapy treatment uncertainties on the delivered dose distribution and tumour control probability

    International Nuclear Information System (INIS)

    Booth, J.T.; Zavgorodni, S.F.; Royal Adelaide Hospital, SA

    2001-01-01

    Uncertainty in the precise quantity of radiation dose delivered to tumours in external beam radiotherapy is present due to many factors, and can result in either spatially uniform (Gaussian) or spatially non-uniform dose errors. These dose errors are incorporated into the calculation of tumour control probability (TCP) and produce a distribution of possible TCP values over a population. We also study the effect of inter-patient cell sensitivity heterogeneity on the population distribution of patient TCPs. This study aims to investigate the relative importance of these three uncertainties (spatially uniform dose uncertainty, spatially non-uniform dose uncertainty, and inter-patient cell sensitivity heterogeneity) on the delivered dose and TCP distribution following a typical course of fractionated external beam radiotherapy. The dose distributions used for patient treatments are modelled in one dimension. Geometric positioning uncertainties during and before treatment are considered as shifts of a pre-calculated dose distribution. Following the simulation of a population of patients, distributions of dose across the patient population are used to calculate mean treatment dose, standard deviation in mean treatment dose, mean TCP, standard deviation in TCP, and TCP mode. These parameters are calculated with each of the three uncertainties included separately. The calculations show that the dose errors in the tumour volume are dominated by the spatially uniform component of dose uncertainty. This could be related to machine specific parameters, such as linear accelerator calibration. TCP calculation is affected dramatically by inter-patient variation in the cell sensitivity and to a lesser extent by the spatially uniform dose errors. The positioning errors with the 1.5 cm margins used cause dose uncertainty outside the tumour volume and have a small effect on mean treatment dose (in the tumour volume) and tumour control. Copyright (2001) Australasian College of

  17. The DOSIS -Experiment onboard the Columbus Laboratory of the International Space Station -Overview and first mission results

    Science.gov (United States)

    Reitz, Guenther; Berger, Thomas; Kürner, Christine; Burmeister, Sünke; Hajek, Michael; Bilski, Pawel; Horwacik, Tomasz; Vanhavere, Filip; Spurny, Frantisek; Jadrnickova, Iva; Pálfalvi, József K.; O'Sullivan, Denis; Yasuda, Nakahiro; Uchihori, Yukio; Kitamura, Hisashi; Kodaira, Satoshi; Yukihara, Eduardo; Benton, Eric; Zapp, Neal; Gaza, Ramona; Zhou, Dazhuang; Semones, Edward; Roed, Yvonne; Boehme, Matthias; Haumann, Lutz

    Besides the effects of the microgravity environment, and the psychological and psychosocial problems encountered in confined spaces, radiation is the main health detriment for long dura-tion human space missions. The radiation environment encountered in space differs in nature from that on earth, consisting mostly of high energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones encountered on earth for occupational radiation workers. Accurate knowledge of the physical characteristics of the space radiation field in dependence on the solar activity, the orbital parameters and the different shielding configurations of the International Space Station ISS is therefore needed. The DOSIS (Dose Distribution inside the ISS) experiment, under the project and science lead of DLR, aims for the spatial and tempo-ral measurement of the radiation field parameters inside the European Columbus laboratory onboard the International Space Station. This goal is achieved by applying a combination of passive (Thermo-and Optical luminescence detectors and Nuclear track etch detectors) and active (silicon telescope) radiation detectors. The passive radiation detectors -so called pas-sive detector packages (PDP) are mounted at eleven positions within the Columbus laboratory -aiming for a spatial dose distribution measurement of the absorbed dose, the linear energy transfer spectra and the dose equivalent with an average exposure time of six months. Two active silicon telescopes -so called Dosimetry Telescopes (DOSTEL 1 and DOSTEL 2) together with a Data and Power Unit (DDPU) are mounted within the DOSIS Main Box at a fixed loca-tion beneath the European Physiology Module (EPM) rack. The DOSTEL 1 and DOSTEL 2 detectors are positioned at a 90 angle to each other for a precise measurement of the temporal and spatial variation of the radiation field, especially during crossing of the South Atlantic Anomaly (SAA). The DOSIS hardware was launched with the

  18. Absorbed dose in the fetus of a pregnant patient when I{sup 131} (iodide/Tc{sup 99m} (pertechnetate) is administered during thyroid studies; Dosis absorbida en el feto de una paciente embarazada cuando se administra I{sup 131} (yoduro)/Tc{sup 99m} (pertecnetato) durante estudios tiroideos

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, V.; Arbayza F, J.; Sanchez S, P.; Cabrera S, C., E-mail: marvva@hotmail.com [Universidad Nacional de Trujillo, Laboratorio de Fisica Nuclear, Trujillo (Peru)

    2016-10-15

    The radiation absorbed dose in the fetus of a pregnant woman during thyroid studies is estimated through the analysis of the bio-kinetics of radiopharmaceuticals containing I{sup 131} (iodide) or Tc{sup 99m} (pertechnetate). MIRD formalism and its representation Cristy-Eckerman are used. The results indicate that the absorbed dose by the fetus of a woman of 3, 6 and 9 months of gestation due to Tc{sup 99m} emissions is lower than that obtained by I{sup 131}; represent 34.7%, 6% and 3.5% of the dose generate by the iodide. The auto-dose in the fetus of a pregnant woman is mainly due to the local energy deposition of the beta and gamma emissions of I{sup 131}, being greater than the one reported by the gamma emissions and conversion electrons of the Tc{sup 99m}, for fetuses of 6 and 9 months. The dose incorporated to the fetus due to the organs of the maternal tissues, which are part of the bio-kinetics, are basically due to the emission of its gamma photons and correspond to 38.50% /60.52% in fetuses of 3 months, 64.71% /12.43% in fetuses of 6 months and 69.79% /10.97% in fetuses of 9 months for the radiopharmaceuticals Tc{sup 99m} (pertechnetate) / I{sup 131} (iodide). The organs of bio-kinetics that contribute to the fetus dose are mainly due to the bladder, followed by the rest, and small intestine (fetuses of 3 months); of the rest, followed by the small intestine and bladder (fetuses of 6 months); of the bladder, followed by the small intestine and stomach (fetuses of 9 months) when using I{sup 131}; while for the Tc{sup 99m} the bladder and rest contribute (fetuses of 3 months); of the placenta, followed by the rest and bladder (fetuses of 6 and 9 months). (Author)

  19. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  20. Evaluation of absorbed dose in studies of renal function due to {sup 123}I/{sup 131}I (hippuran) e {sup 111}In (DPTA); Evaluacion de la dosis absorbida durante estudios de la funcion renal debido al {sup 123}I/{sup 131}I (hippuran) e {sup 111}In (DPTA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.V.; Castillo, C.E.; Rojas, R.; Cabrera, C.; Abanto, D.; Morgan, A. [Universidad Nacional de Trujillo (UNT), Area de Fisica Medica, Trujillo (Peru); Diaz, E.E., E-mail: marvva@hotmail.com [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre (Brazil)

    2015-07-01

    The absorbed dose of the kidneys during renal function studies of adult patients is estimated through biokinetics of radiopharmaceuticals containing the {sup 123}I/{sup 131}I (hippuran) e {sup 111}In (DPTA). Using the methodology MIRD and representation Cristy-Eckerman for adult kidneys, it is shown that dosimetric contributions of organs of biokinetics {sup 123}I/{sup 131}I (hippuran) e {sup 111}In (DPTA) are significant, in estimative of dose for renal function studies. Dosimetric contributions (body and whole bladder, kidneys excluding) are given by 11.90% (for {sup 123}I), 4.97% (for {sup 131}I) and 28.32% (for {sup 111}In). In all cases, the dosimetric contributions are mainly due to photons issued by the whole body.

  1. The methodology proposed to estimate the absorbed dose at the entrance of the labyrinth in HDR brachytherapy facilities with IR-192; Propuesta de metodologia para estimar la dosis absorbida en la entrada del laberinto en instalaciones de braquiterapia HDR con Ir-192

    Energy Technology Data Exchange (ETDEWEB)

    Pujades, M. C.; Perez-Calatayud, J.; Ballester, F.

    2012-07-01

    In the absence of procedure for evaluating the design of a brachytherapy (BT) vault with maze from the point of view of radiation protection, usually formalism of external radiation is adapted. The purpose of this study is to adapt the methodology described by the National council on Radiological Protection and Measurements Report 151 (NCRP 151). Structural Shielding Design for megavoltage X-and Gamma-Ray Radiotherapy facilities, for estimating dose at the door in BT and its comparison with the results megavoltage X-and Gamma-Ray Radiotherapy Facilities, for estimating dose at the door in BT and its comparison with the results obtained by the method of Monte Carlo (MC) for a special case of bunker. (Author) 17 refs.

  2. Optimization of the dose absorbed in pediatric CT studies according to the methodology of the report n. 204 of the AAPM; Optimizacion de la dosis absorbida en estudios de TC pediatricos segun la metodologia del report n. 204 de la AAPM

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Rodriguez, J.; Arino Gil, A.; Mateos Salvador, P.; Rodriguez, B.; Font Gelabert, J. C.

    2013-07-01

    The objective of this study is to determine the SSDE for a sample of pediatric patients grouped into 4 ranges of ages for different anatomical locations: skull, thorax, and abdomen. The SSDE values obtained are compared with the diagnostic levels of reference (NDR) for different countries 4 (expressed in CTDIvol). The goodness of the SSDE as parameter is evaluated to estimate the dose in CT. (Author)

  3. Evaluation of cell death mechanisms activated by the administration of the theranostics radiopharmaceutical {sup 177}Lu-DOTA-anti-CD20 in a dose range of 1-5 Gy; Evaluacion de los mecanismos de muerte celular activados por la administracion del radiofarmaco teranostico {sup 177}Lu-DOTA-anti-CD20 en un rango de dosis de 1-5 Gy

    Energy Technology Data Exchange (ETDEWEB)

    Martinez V, B. E.

    2016-07-01

    Radio-immunotherapy with anti-CD20 antibodies significantly increases the rate of remission in patients with CD20 over expressing B-cell lymphomas. Radio-labeled antibodies directed to surface antigens allow delivering scaled doses of radiation to specific targets thus limiting the dose to healthy tissue. Anti-CD20 causes cell death by two major pathways; activating the immune system to destroy malignant cells and inducing the activation of cell death pathways. The {sup 177}Lu is a beta particle emitter (max. 0.497 MeV) with a maximum soft tissue reach of 0.7 mm and a half-life of 6.7 days. Several clinical studies have established a maximum tolerated dose (45m Ci/m{sup 2}) for {sup 177}Lu-DOTA-rituximab, which shows a favorable clinical response without hematological toxicity. However, the molecular mechanisms of synergistic activation of anti-CD20 and radionuclide have not been studied. In this work we evaluated by flow cytometry, the activation kinetics of the cell death mechanisms induced by the treatment with {sup 177}Lu-DOTA-anti-CD20 from non-Hod king lymphoma cells (Raji). The absorbed radiation dose delivered to the cell nucleus was calculated by Monte Carlo simulation, considering the contribution of the beta emissions of the radiopharmaceutical present in the cell membrane and surrounding environment, as well as crossfire. This work shows that the application of radiation doses of 1 to 5 Gy of the radiopharmaceutical {sup 177}Lu-DOTA-anti-CD20 are sufficient to induce cell death by apoptosis and arrest of the cell cycle. The combination of these factors (continuous delivery of radiation activation of repair mechanisms and increased radio-sensitivity) causes acute activation of the apoptotic program resulting in significant cell death after 96 h of treatment. The temporal analysis of cell death suggests the early activation of apoptosis that is counteracted by the activation of repair processes caused by sustained irradiation, which leads to cell arrest

  4. Evaluation of the cell death mechanisms activated by the radiopharmaceutical {sup 177}Lu-DOTA-anti-CD20 in a dose range of 1 to 5 Gy; Evaluacion de los mecanismos de muerte celular activados por el radiofarmaco {sup 177}Lu-DOTA-anti-CD20 en un intervalo de dosis de 1 a 5 Gy

    Energy Technology Data Exchange (ETDEWEB)

    Azorin V, E.P.; Rojas C, E. L.; Martinez V, B. E.; Ramos B, J. C.; Jimenez M, N. P.; Ferro F, G., E-mail: erica.azorin@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-10-15

    The radio immunotherapy with anti-CD20 antibodies significantly increases the remission rate of patients with B-cell lymphomas over expressing the CD20. The radiolabeled antibodies directed to surface antigens allow delivering scaled doses of radiation to specific targets thus limiting the dose to healthy tissue. The anti-CD20 causes cell death by two major pathways; activating the immune system to destroy malignant cells and inducing the activation of cell death pathways. The {sup 177}Lu is a beta particle emitter (max. 0.497 MeV) with a maximum reach on soft tissue of 0.7 mm and a half-life of 6.7 days. Several clinical studies have established a maximum tolerated dose (45 m Ci/m{sup 2}) for {sup 177}Lu-DOTA-rituximab, which shows a favorable clinical response without hematological toxicity. However, the molecular mechanisms of action by synergistic effect of anti-CD20 and radionuclide have not been studied. In this work was evaluated; by flow cytometry, the activation kinetics of the cell death mechanisms induced by the treatment with {sup 177}Lu-DOTA-Anti-CD20 in non-Hodgkin (Raji) lymphoma cells. The absorbed radiation dose delivered to the cell nucleus was calculated by Monte Carlo simulation, considering the contribution of the beta emissions of the radiopharmaceutical present in the cell membrane and surrounding environment, as well as crossfire. This work shows that the application of radiation doses of 1 to 5 Gy of the radiopharmaceutical {sup 177}Lu-DOTA-anti-CD20, are sufficient to induce cell death by apoptosis and arrest of the cell cycle. The combination of these factors (continuous delivery of radiation, activation of repair mechanisms and increased radio sensitivity) causes the acute activation of the apoptotic program resulting in significant cell death after 96 h of treatment. The temporal analysis of cell death suggests the early activation of apoptosis that is counteracted by the activation of repair processes caused by sustained irradiation

  5. Analysis of equivalent dose (H) starting from the exposition (X) received for patient families in myocardial perfusion study with {sup 99m}Tc-Sestamibi; Analisis de dosis equivalente (H) a partir de la exposicion (X) recibida por familiares de pacientes en estudio de perfusion miocardica con {sup 99m}Tc-Sestamibi

    Energy Technology Data Exchange (ETDEWEB)

    Martinez H, I.; Vazquez E, R.; Jimenez A, L., E-mail: irmarinc@yahoo.com.m [Instituto Nacional de Cardiologia Ignacio Chavez, Departamento de Cardiologia Nuclear, Juan Badiano No. 1, Colonia Seccion XVI, 14080 Mexico D. F. (Mexico)

    2010-09-15

    The myocardial perfusion study with {sup 99m}Tc-Sestamibi has the major indication frequency for the coronary arterial illness diagnostic, due to its high sensibility and specificity. The patient families that are exposed to this study also receive the radiation of the injected radiopharmaceutical. The punctual source model (Psm) is generally used for the absorbed dose calculation of the radiation coming from patients under any procedure with radiopharmaceuticals. The objective of this study was to compare the equivalent doses calculated theoretically (Dat) by means of Psm, regarding the measurements that routinely are made by means of a detector Geiger (Dam), as well as to quantify the maxim equivalent dose to which they are exposed the families of the subjected patients to this procedure. 30 voluntary patients were evaluated with clinical indication for myocardial perfusion study with {sup 99m}Tc-Sestamibi with acquisition protocol of 1 day: Rest-effort, with dose of 15-30 mCi (555-1110 mBq) respectively. Immediate to each injection of {sup 99m}Tc-Sestamibi was calculated the Dat, using the equation that the Psm describes, considering a distance of 1 meter; and the exposition speed was measured by means of a detector Geiger at a distance 1 meter to the heart height. The measurements comparison (Dat vs Dam) was realized by means of the test statistical t-student for independent samples, considering a significance level p{<=}0.05. For the data of the second injection, was realized a regression analysis to evaluate the lineal correlation among both measurements. Immediately after the injection of 15 mCi (555 mBq) of {sup 99m}Tc-Sestamibi, the values of the Dam (1.37{+-}0.43 mrem, 13.7{+-}4.3 {mu}Sv) they differ significantly of the Dat (1.04 mrem, p<0.05) (10.4 {mu}Sv). The second injection of 30 mCi (1110 mBq) of {sup 99m}Tc-Sestamibi was carried out in an average time of 2.57{+-}0.02 hr, having the patients group a calculated initial activity of 11.14{+-}0.76 m

  6. Avaliação do estado ácido-básico materno com o uso de sufentanil por via subaracnóidea em diferentes doses para cesarianas e suas repercussões sobre os recém-nascidos Evaluación del estado ácido-básico materno con el uso de sufentanil por vía subaracnóidea en diferentes dosis para cesáreas y sus repercusiones sobre los recién nacidos Evaluation of maternal acid-base status after different doses of spinal sufentanil for cesarean section and its effects on the neonates

    Directory of Open Access Journals (Sweden)

    Luís Fernando Lima Castro

    2003-02-01

    efecto colateral más grave la depresión respiratoria. Se objetivó en este estudio evaluar el estado ácido-básico materno con el uso de sufentanil subaracnóideo en diferentes dosis, asociado a la bupivacaína hiperbárica, para cesáreas y sus repercusiones sobre los recién nacidos. MÉTODO: Fueron evaluadas 40 gestantes a término, estado físico ASA I , con edades entre 17 y 35 años, sometidas a cesárea electiva bajo raquianestesia y divididas en 2 grupos equitativos: en el grupo I recibieron 12 mg de bupivacaína a 0,5% hiperbárica asociados a 2,5 µg de sufentanil y en el grupo II recibieron 12 mg de bupivacaína a 0,5% hiperbárica asociados a 5 µg de sufentanil. Fueron evaluados: estado ácido-básico materno a través de gasometria arterial antes de la realización de la anestesia y después del nacimiento del concepto, SpO2, alteraciones hemodinámicas, vitalidad de los recién nacidos a través del índice de Apgar y gasometria del cordón umbilical y presencia de efectos colaterales. RESULTADOS: Los grupos se mostraron homogéneos en los parámetros evaluados, observándose discreta acidosis metabólica materna compensada en ambos grupos tanto antes de la realización de la anestesia como luego después del nacimiento del concepto, no obstante, sin repercusiones clínicas. Los recién nacidos presentaron buena vitalidad y gasometrias compatibles con la normalidad. CONCLUSIONES: La asociación de bupivacaína hiperbárica en pequeñas dosis de sufentanil subaracnóideo en cesáreas mostró que es la técnica segura al binomio materno-fetal, preservando su estado hemodinámico y ácido-básico.BACKGROUND AND OBJECTIVES: Spinal sufentanil in obstetric anesthesia promotes immediate pain relief, improves anesthesia quality and prolongs postoperative analgesia, its major side effect being respiratory depression. This study aimed at evaluating maternal acid-base status after different doses of spinal sufentanil associated to hyperbaric bupivacaine for

  7. Calculus of spatial distribution of absorbed dose to cellular level by Monte Carlo simulation for a radio-labelled peptide with {sup 188}Re and with nuclear internalization : preliminary results; Calculo de la distribucion espacial de dosis absorbida a nivel celular por simulacion Monte Carlo para un peptido radiomarcado con {sup 188}Re y con internalizacion nuclear : resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E. L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Santos C, C. L. [Universidad Autonoma del Estado de Mexico, Paseo Tollocan y Jesus Carranza, Toluca 50120, Estado de Mexico (Mexico)], e-mail: leticia.rojas@inin.gob.mx

    2009-10-15

    The {sup 188}Re is a radionuclide of radiation gamma emitter, useful in obtaining of gamma-graphic images, but it is also emitter of beta radiations and Auger electrons. A bio-molecule directed to a specific receptor of a cancer cell labeled with a emitter radionuclide of beta particles and Auger electrons, as the {sup 188}Re-Tat-Bombesin, it has the potential to be used in radiotherapy of molecular targets for its capacity to penetrate to cellular nucleus. In this system, the radiation dose is distributed in way located at microscopic levels in sub cellular specific places, where Auger emissions contributes of significant way in absorbed dose. The cellular dosimetry is realized in most of cases, using analytic or semi analytical methods, for example the cellular MIRD methodology. However, it is required to complement these calculations simulating the electrons transport and considering experimental bio kinetics data. Therefore, in this work preliminary results are presented of dosimetric calculation to sub cellular level for {sup 188}Re-Tat-Bombesin by Monte Carlo simulation, using the 2008 version of PENELOPE: PENEASY code. The spatial distribution of absorbed dose in membrane, cytoplasm and nucleus, was calculated with geometry of a cell of 10 {mu}m of diameter, a nucleus of 2 {mu}m of ratio and membrane of 0.2 {mu}m of thickness, considering elementary constitution for each cellular compartment proposal in literature. The total number of disintegrations at sub cellular level was evaluated integrating the activity in function of time starting from experimental bio kinetics data in mamma cancer cells MDA-MB231. The preliminary results show that 46.4% of total disintegrations for unit of captured activity by cell occurs in nucleus, 38.4% in membrane and 15.2% in cytoplasm. The due absorbed dose to Auger electrons for 1 Bq of {sup 188}Re located in cellular membrane were respectively of 1.32E-1 and 1.43E-1 Gy in cytoplasm and nucleus. (Author)

  8. Radiotherapy with linear accelerator in a patient with permanent pacemaker, methodology and results of dose determination in a case in vivo; Radioterapia con Linac en un paciente con marcapasos permanente, metodologia y resultados de determinacion de dosis en un caso in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Diaz A, P.; Dominguez O, X.; Toledo B, V.; Nungaray, H.; Zazueta L, F., E-mail: pdiaz@hospitalsanjavier.co [Hospital San Javier, Pablo Casals No. 640, Col. Prados Providencia, 44670 Guadalajara, Jalisco (Mexico)

    2010-09-15

    This work presents the methodology used by the radiotherapy department of the Hospital San Javier in the patients handling with pacemaker. By means of dosimetry to the implant area of the pacemaker together with electrocardiography measurements during the radiotherapy sessions, the pacemaker performance is evaluated with the objective of detecting any anomaly to the same caused by electromagnetic interference and/or accumulated dose. It is necessary to follow specific protocols in these patients type that guarantee their security during the exposition to ionizing radiation since a definitive consent that allows to calculate the failure probability of pacemaker in this therapeutic condition does not exist. (Author)

  9. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt; Medicion de curvas de extrapolacion para el patron secundario de radiacion beta Nr. 86 calibrado en rapidez de dosis absorbida para tejido equivalente por el Physikalisch Technische Bundesanstalt

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T

    1988-10-15

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  10. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    Science.gov (United States)

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  11. Respuesta del garbanzo (Cicer arietinum L. a la inoculación con Azotobacter vineladii y Burkholderia cepacia a dosis reducida de fertilizante nitrogenado

    Directory of Open Access Journals (Sweden)

    Juan Manuel Sánchez-Yáñez

    2014-01-01

    Full Text Available ResumenEl cultivo de garbanzo “Cicer arietinumL.” demanda fertilizante nitrogenado (FN, que aplicado en excesoprovoca pérdida de fertilidad del suelo y contaminación ambiental. Una alternativa para este problema es lareducción y optimización de la dosis de FN, con inoculantes a base de bacteriaspromotoras de crecimientovegetal (BPCV.Así, el objetivo de este trabajo fue analizar la respuesta del garbanzo a la inoculación conAzotobactervinelandiiyBurkholderiacepaciaa la dosis 50% del FN. Para ello se utilizó un diseñoexperimental de bloques al azar. Con nitrato de amonio (NO3NH4 como FN a las dosis 100% (10g/L y 50 %(5g/L para el garbanzo inoculado con las BPCV; con las variables/respuesta en su semilla: por ciento (% degerminación; luego su fenotípia y biomasa aérea y radical, los datos experimentales se analizaron por ANOVAy Tukey. Los resultados indicaron una respuesta positiva de la semilla de garbanzo a la doble inoculación conambas BPCV, al igual que aplántula y floración, donde el garbanzo alcanzo un peso seco total (PST de 0,82g, valor estadísticamente diferente y significativo, comparado con los 0,71g de PST del garbanzo sin inocularcon el FN al 100% o control relativo (CR. Lo anterior sugiereuna respuesta positiva del garbanzo queoptimizó la dosis 50% del FN, por una acción sinérgica de los dos géneros de BPCV en sus raíces, lo quepodría evitar en parte la perdida de fertilidad del suelo y la contaminación ambiental, por la aplicación enexceso del FN.

  12. Radiological protection on interstitial brachytherapy and dose determination and exposure rate of an Ir-192 source through the MCNP-4B; Proteccion radiologica en braquiterapia intersticial y determinacion de la dosis y tasa de exposicion de una fuente de Ir-192 mediante el MCNP-4B

    Energy Technology Data Exchange (ETDEWEB)

    Morales L, M.E. [INEN, Av. Angamos Este 2520- Surquillo, Lima (Peru)

    2006-07-01

    The present work was carried out in the Neurological Sciences Institute having as objective to determine the dose and the rate of exhibition of the sources of Iridium 192, Iodine 125 and Palladium 103; which are used to carry out implant in the Interstitial Brachytherapy according to the TG43. For it we carry out a theoretical calculation, its are defined in the enter file: the geometry, materials of the problem and the radiation source, etc; in the MCNP-4B Monte Carlo code, considering a punctual source and for the dose determination we simulate thermoluminescent dosemeters (TLD): at 5 cm, 50 cm, 100 cm and 200 cm of the source. Our purpose is to analyze the radioprotection measures that should take into account in this Institute in which are carried out brain biopsies using a Micro mar stereotactic mark, and in a near future with the collaboration of a doctor and a cuban physique seeks to be carried out the Interstitial Brachytherapy technique with sources of Ir-192 for patient with tumors like glioblastoma, astrocytoma, etc. (Author)

  13. Calculations of doses for the personnel wrapped up in the radiological accident of the Specialties Hospital of the National Medical Center ''Siglo XXI''; Calculos de dosis para el personal involucrado en el accidente radiologico del Hospital de Especialidades del Centro Medico Nacional ''Siglo XXI''

    Energy Technology Data Exchange (ETDEWEB)

    Cortes C, A. [CNSNS, Dr. Barragan 779, Col Narvarte, Mexico D.F. (Mexico)]. e-mail: acortes@cnsns.gob.mx

    2004-07-01

    In this work the methodology used by the National Commission of Nuclear Safety and Safeguards for the determination of the internal dose due to the ingestion of coffee with I-131 for the personnel of the service of nuclear medicine of the Hospital of Specialties of the National Medical Center ''Siglo XXI'' of the Mexican Institute of the Social Insurance (IMSS), that was poured in the coffeepot of the service by a deliberate act before mentioned, is presented. Three different techniques were used to determine the initial activity incorporated starting from the measurements of retained activity in thyroid for 6 people of the service of nuclear medicine; the techniques employee provided consistent results. Using the results of the technique of the best estimator, it was applied the proposed methodology by the International Commission of Radioprotection in its publication 30 to determine the absorbed doses by the personnel involved in the accident, with which the Commission determines the administrative consequences to those that it should be held the personnel and the directive of the service of nuclear medicine of the one nosocome. (Author)

  14. Dose calculation in eye brachytherapy with Ir-192 threads using the Sievert integral and corrected by attenuation and scattering with the Meisberg polynomials; Calculo de dosis en braquiterapia ocular con hilos de Ir-192 utilizando la integral de Sievert y cooregida por atenuacion y dispersion con los polinomios de Meisberg

    Energy Technology Data Exchange (ETDEWEB)

    Vivanco, M.G. Bernui de; Cardenas R, A. [Instituto Nacional de Enfermedades Neoplasicas, Universidad Nacional de Ingenieria, Av. Angamos No. 2520, Surquillo, Lima (Peru)]. e-mail: gisellebdv@hotmail.com

    2006-07-01

    The ocular brachytherapy many times unique alternative to conserve the visual organ in patients of ocular cancer, one comes carrying out in the National Institute of Neoplastic Illnesses (INEN) using threads of Iridium 192; those which, they are placed in radial form on the interior surface of a spherical cap of gold of 18 K; the cap remains in the eye until reaching the prescribed dose by the doctor. The main objective of this work is to be able to calculate in a correct and practical way the one time that the treatment of ocular brachytherapy should last to reach the dose prescribed by the doctor. To reach this objective I use the Sievert integral corrected by attenuation effects and scattering (Meisberg polynomials); calculating it by the Simpson method. In the calculations by means of the Sievert integral doesn't take into account the scattering produced by the gold cap neither the variation of the constant of frequency of exposure with the distance. The calculations by means of Sievert integral are compared with those obtained using the Monte Carlo Penelope simulation code, where it is observed that they agree at distances of the surface of the cap greater or equal to 2mm. (Author)

  15. Implementation of a model of atmospheric dispersion and dose calculation in the release of radioactive effluents in the Nuclear Centre; Implementacion de un modelo de dispersion atmosferica y calculo de dosis en la liberacion de efluentes radiactivos en el Centro Nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Cruz L, C. A.

    2015-07-01

    In the present thesis, the software DERA (Dispersion of Radioactive Effluents into the Atmosphere) was developed in order to calculate the equivalent dose, external and internal, associated with the release of radioactive effluents into the atmosphere from a nuclear facility. The software describes such emissions in normal operation, and not considering the exceptional situations such as accidents. Several tools were integrated for describing the dispersion of radioactive effluents using site meteorological information (average speed and wind direction and the stability profile). Starting with the calculation of the concentration of the effluent as a function of position, DERA estimates equivalent doses using a set of EPA s and ICRP s coefficients. The software contains a module that integrates a database with these coefficients for a set of 825 different radioisotopes and uses the Gaussian method to calculate the effluents dispersion. This work analyzes how adequate is the Gaussian model to describe emissions type -puff-. Chapter 4 concludes, on the basis of a comparison of the recommended correlations of emissions type -puff-, that under certain conditions (in particular with intermittent emissions) it is possible to perform an adequate description using the Gaussian model. The dispersion coefficients (σ{sub y} and σ{sub z}), that using the Gaussian model, were obtained from different correlations given in the literature. Also in Chapter 5 is presented the construction of a particular correlation using Lagrange polynomials, which takes information from the Pasquill-Gifford-Turner curves (PGT). This work also contains a state of the art about the coefficients that relate the concentration with the equivalent dose. This topic is discussed in Chapter 6, including a brief description of the biological-compartmental models developed by the ICRP. The software s development was performed using the programming language Python 2.7, for the Windows operating system (the

  16. Evaluation of a pyrex glass shield for the dose reduction in extremities to manipulate a {sup 90} Sr- {sup 90} Y generator; Evaluacion de un blindaje de vidrio pyrex para la reduccion de las dosis en extremidades al manipular un generador de {sup 90} Sr- {sup 90} Y

    Energy Technology Data Exchange (ETDEWEB)

    Ayra P, F.E.; Xiques C, A.; Torres B, M.B. [Centro de Isotopos, Carretera La Rada, Km 3 1/2, Guanabacoa, La Habana (Cuba)]. e-mail: feayra@centis.edu.cu

    2006-07-01

    The production of Y-90 of high activity it specifies (free of payee) for their use in radioimmunotherapy uses the Strontium 90 as isotope source. Depending on the method employee for the separation of both isotopes several types of generators are described in different bibliographies. The column generator used in the facilities of the Center of Isotopes requires of a frequent manipulation causing significant dose in the skin of the extremities due to the exhibition to the radiation beta of high energy. The properties of the shieldings for this radiation type have been well studied Y they consist in several publications. To be in correspondence with requirements of radiological protection in the Cuban legislation, the column was covered with a tube of glass pyrex of 5 mm of thickness and it was monitored the exposure with an ionization chamber. At the own time, the shielding using the Monte Carlo method was evaluated. It was used the MCNP 4C code to simulate the absorption of the beta particles generated in the process of disintegration of the Sr-90 and Y-90 in the glass shielding. The column generator and the fluence of beta particles were modeled in different points inside the shielding to determine if the experimentally measured values correspond to electrons that were not absorbed or to the weak stopping radiation generated in the glass due to the deceleration of these particles. A cylinder of 4 mm of diameter simulates the source (it dilutes) and a tube of walls of 6 mm of thickness simulates the shielding more the wall of the column around the generator. This it was divided in cells of 1 mm of thickness and the energy deposited in them was evaluated. The results show that all the electrons generated in the source are absorbed in the shielding and the exposure rates decrease in more of 78 times using the 5 mm of pyrex glass. The doses in extremities to the operators of the generator don't surpass the 70 mSv by year that is the dose restriction imposed in

  17. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba; Automatizacion del monitoreo en tiempo real de la tasa de dosis absorbida en aire debido a la radiacion gamma ambiental en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez L, O; Capote F, E; Carrazana G, J A; Manzano de Armas, J F; Alonso A, D; Prendes A, M; Zerquera, J T; Caveda R, C A [CPHR, Calle 20, No. 4113 e/41 y 47, Playa, La Habana, 11300, A.P. 6195 C.P. 10600 (Cuba); Kalberg, O [Swedish Radiation Protection Institute (SSI) (Sweden); Fabelo B, O; Montalvan E, A [CIAC, Camaguey (Cuba); Cartas A, H [CEAC, Cienfuegos (Cuba); Leyva F, J C [CISAT (Cuba)

    2006-07-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  18. Measurement and monitoring of entrance exposure dose rate in X-ray image intensifier television with dose rate control

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J [Bezirkskrankenhaus Brandenburg (German Democratic Republic)

    1981-03-01

    For X-ray image intensifier television operation very low entrance dose rates (about 5.2 nA/kg) are stated and demanded, respectively. These required values are often manifold exceeded in practice so that a check seems to be necessary. It is shown and proved how these measurements can be performed with simple, generally available means of measurement in the radiological practice. For ZnCdS-image intensifiers should be considered that about 13 nA/kg for the large entrance size are not to be exceeded; for the CsI type lower values (factor 1.5) are practicable because of the twofold quantum absorption efficiency. Furthermore, some tests for a semiquantitative function check of the automatic dose rate control are proposed.

  19. Optimasi Dosis Pupuk Dolomit pada Tanaman Kelapa Sawit (Elaeis Guineensis Jacq. Belum Menghasilkan Umur Satu Tahun

    Directory of Open Access Journals (Sweden)

    - Sudradjat

    2015-09-01

    Full Text Available Kelapa sawit merupakan komoditi perkebunan utama karena sebagai sumber devisa negara dan menyediakan lapangan kerja. Indonesia adalah negara produsen terbesar kelapa sawit di dunia dengan luas areal mencapai 10.1 juta hektar. Peningkatan produktivitas dicapai dengan intensifikasi antara lain dengan melakukan rasionalisasi pemupkan. Penelitian ini bertujuan untuk menentukan dosis optimum pupuk dolomit pada tanaman kelapa sawit belum menghasilkan umur satu tahun. Penelitian ini dilaksanakan di Kebun Pendidikan dan Penelitian Kelapa Sawit IPB-Cargill, Jonggol, Bogor dari bulan Maret 2013 sampai Maret 2014. Rancangan yang digunakan adalah Faktorial Tunggal,  dosis pupuk dolomit,  yang disusun dalam lingkungan Acak Kelompok dengan tiga ulangan. Dosis pupuk dolomit yang diuji  terdiri atas 0, 200, 400, dan 600 g tanaman-1 tahun-1. Hasil penelitian menunjukkan bahwa pupuk dolomit meningkatkan secara nyata terhadap peubah tinggi tanaman, diameter batang, jumlah daun, dan kandungan khlorofil daun, namun tidak berpengaruh terhadap kandungan Mg dalam jaringan daun. Berdasarkan tanggap peubah tinggi tanaman, dosis optimum pupuk dolomit untuk tanaman kelapa sawit pada umur satu tahun adalah 306.4 g dolomit tanaman-1tahun -1. Kata kunci: dolomit, dosis optimum, kelapa sawit, respons fisiologi, respons morfologi.

  20. Control of internal exposure doses of Belarus population

    International Nuclear Information System (INIS)

    Minenko, V.; Drozdovich, V.; Ulanovski, A.; Ternov, V.I.; Vasilyeva, I.

    1997-01-01

    Starting from May 1986 instrumental control of internal exposure is being carried out in Belarus using different equipment. In earlier, iodine period, the basic aim of the control was a mass screening of the population for defining of iodine content in thyroid. After the iodine period attention of the radiological control was focused on monitoring of caesium radionuclides content in human bodies of the inhabitants of radioactively contaminated territories. Goals of the control were changing, depending on the time that passed since the day of the accident. Nowadays the National Commission of Belarus recognizes entering of the, Republic into rehabilitation period of the accident of the Chernobyl Nuclear Power Plant. Developed Conception of Protection Measures for the rehabilitation period for the population living at the territories affected by the radioactive contamination in the result of the Chernobyl catastrophe

  1. Sibutramine in weight control: a dose-ranging, efficacy study.

    Science.gov (United States)

    Weintraub, M; Rubio, A; Golik, A; Byrne, L; Scheinbaum, M L

    1991-09-01

    We tested the safety and efficacy of sibutramine, 5 and 20 mg, and placebo on weight loss. Medication was added to caloric restriction, behavior modification, and exercise in a parallel-group, double-blind clinical trial. Participants were 130% to 180% of ideal body weight and in good health. The study lasted 12 weeks over Thanksgiving, Christmas, and New Year's Day. Weight loss during 8 weeks of study medication was: placebo, 1.4 +/- 2.1 kg (n = 19); 5 mg sibutramine, 2.9 +/- 2.3 kg (n = 18); and 20 mg sibutramine, 5.0 +/- 2.7 kg (n = 18) (p less than 0.05 sibutramine, 5 and 20 mg, versus placebo; p less than 0.05 sibutramine, 20 mg versus 5 mg). There is a significant dose-effect relationship. Five participants left the study before completion, all because of adverse events; placebo (one patient), 5 mg sibutramine (one patient), and 20 mg sibutramine (three patients). Sleep difficulties were noted by eight participants (20 mg sibutramine, seven patients; 5 mg, one patient; and placebo, no patients). Six of 21 participants receiving 20 mg complained of irritability, unusual impatience, or "excitation." Sibutramine, 5 and 20 mg, added to a multimodal program assisted participants in losing weight.

  2. Dose management as a measurable criteria into the quality control programme of an imaging diagnostic clinic

    International Nuclear Information System (INIS)

    Kirova, G.; Georgiev, E.; Zasheva, C.; Georgiev, S.

    2014-01-01

    In the Radiology Department of Tokuda Hospital Sofia, a strong control over the radiation dose for all patients was accepted with the implementation of the Dose Watch software. The system allows bad practices to be discovered and improves the efficiency and quality of the CT procedures performed in the department. The article will briefly demonstrate the main steps, which have been done, and the results, which have been achieved. The purpose is to identify the challenges, the available tools, and the opportunities for improving the patients' dose in the CT sector of a general Radiology Department. Collected data was based on the information concerning the radiation dose absorbed by individual patients undergoing MDCT examinations in a general radiology department with an overall annual rate of around 7000 MDCT examinations. All of them were carried out using a single 64row MDCT system. The hospital logbook was used to identify the number of CT examinations and dose levels associated with some typical diagnostic procedures in order to make an analysis. The information was taken form the PACS and Dose Watch software and was analyzed. The article draws some measures towards improving the organization and reducing the dose, keeping the quality of the performed exams. Thanks to the supportive software for dose tracking, analyzing and reporting, some problems have been solved and some reasonable measures have been implemented into the daily practice. (authors) Key words: RADIATION DOSE. MDCT. DOSE REDUCTION. REFERRAL GUIDELINES.CTDI. DLP

  3. Dose control for internal radiation; Kawalan dos untuk sinaran dalam

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The chapter briefly discussed the following subjects: aerosol physics, relationship of surface contamination and internal contamination for workers, surface contamination control and the it`s procedures i.e. protective personnel cloth, waste management in active area, storage of radioactive materials etc.

  4. A randomised controlled trial comparing weight adjusted dose ...

    African Journals Online (AJOL)

    A prophylactic phenylephrine infusion combined with a fluid co-load is proven to be an effective and safe method of maintaining maternal hemodynamic stability. ... for non-urgent caesarean section under spinal anaesthesia were randomized into 2 groups; control group and intervention group using a computer generated ...

  5. Dose prescription complexity versus tumor control probability in biologically conformal radiotherapy

    International Nuclear Information System (INIS)

    South, C. P.; Evans, P. M.; Partridge, M.

    2009-01-01

    The technical feasibility and potential benefits of voxel-based nonuniform dose prescriptions for biologically heterogeneous tumors have been widely demonstrated. In some cases, an ''ideal'' dose prescription has been generated by individualizing the dose to every voxel within the target, but often this voxel-based prescription has been discretized into a small number of compartments. The number of dose levels utilized and the methods used for prescribing doses and assigning tumor voxels to different dose compartments have varied significantly. The authors present an investigation into the relationship between the complexity of the dose prescription and the tumor control probability (TCP) for a number of these methods. The linear quadratic model of cell killing was used in conjunction with a number of modeled tumors heterogeneous in clonogen density, oxygenation, or proliferation. Models based on simple mathematical functions, published biological data, and biological image data were investigated. Target voxels were assigned to dose compartments using (i) simple rules based on the initial biological distribution, (ii) iterative methods designed to maximize the achievable TCP, or (iii) methods based on an ideal dose prescription. The relative performance of the simple rules was found to depend on the form of heterogeneity of the tumor, while the iterative and ideal dose methods performed comparably for all models investigated. In all cases the maximum achievable TCP was approached within the first few (typically two to five) compartments. Results suggest that irrespective of the pattern of heterogeneity, the optimal dose prescription can be well approximated using only a few dose levels but only if both the compartment boundaries and prescribed dose levels are well chosen.

  6. Pré-tratamento com água e doses de ácido indolbutírico para estaquia herbácea de pitangueiras Pre-treatments with water and indole butyric acid dosis for herbaceous cuttings of Surinam cherry

    Directory of Open Access Journals (Sweden)

    Daiane Silva Lattuada

    2011-12-01

    Full Text Available No Brasil, a maioria dos pomares de pitangueira (Eugenia uniflora é formada por mudas do tipo pé-franco, o que torna os plantios com baixa uniformidade genética. A propagação vegetativa via estaquia é uma alternativa viável para propagação de diversas espécies frutíferas, podendo ser utilizada também com as espécies nativas, proporcionando a formação de pomares homogêneos, com a produção de mudas com alta sanidade, além de antecipar a produção. Nesse contexto, conduziu-se um estudo visando à multiplicação vegetativa da pitangueira, em que se testou a estaquia herbácea a partir de estacas coletadas de plantas matrizes jovens e adultas, submetidas a três períodos de imersão em água (0, 24 ou 48 horas, além da aplicação de doses de ácido indolbutírico (0, 2000, 4000 e 6000mg L-1. Foram avaliadas a sobrevivência (%, a retenção e a emissão foliar (n° folhas/ estaca, a calogênese (% e enraizamento das estacas (%. Ao final do experimento, avaliou-se massa fresca e seca de parte aérea e raiz, número de folhas e área foliar. O delineamento experimental foi o completamente casualizado, com três repetições de dez plantas por tratamento para os parâmetros não destrutivos e três repetições de cinco plantas por tratamento para os parâmetros destrutivos. A estaquia herbácea foi eficiente para produzir mudas de pitangueira, especialmente quando utilizadas estacas oriundas de plantas jovens sem necessidade de pré-lavagem nem adição de auxinas exógenas.In Brazil, most of the Surinam cherry (Eugenia uniflora orchards is formed by ungrafted plants, which makes the plantations have low genetic uniformity. The vegetative minicutting propagation is a viable alternative for the propagation of several fruit species, and can also be used with native species providing the formation of orchards with homogeneous populations of plants, with production of seedlings with high health and accelerated propagation process

  7. Single and 30 fraction tumor control doses correlate in xenografted tumor models: implications for predictive assays

    International Nuclear Information System (INIS)

    Gerweck, Leo E.; Dubois, Willum; Baumann, Michael; Suit, Herman D.

    1995-01-01

    Purpose/Objective: In a previous publication we reported that laboratory assays of tumor clonogen number, in combination with intrinsic radiosensitivity measured in-vitro, accurately predicted the rank-order of single fraction 50% tumor control doses, in six rodent and xenografted human tumors. In these studies, tumor hypoxia influenced the absolute value of the tumor control doses across tumor types, but not their rank-order. In the present study we hypothesize that determinants of the single fraction tumor control dose, may also strongly influence the fractionaled tumor control doses, and that knowledge of tumor clonogen number and their sensitivity to fractionated irradiation, may be useful for predicting the relative sensitivity of tumors treated by conventional fractionated irradiation. Methods/Materials: Five tumors of human origin were used for these studies. Special care was taken to ensure that all tumor control dose assays were performed over the same time frame, i.e., in-vitro cells of a similar passage were used to initiate tumor sources which were expanded and used in the 3rd or 4th generation. Thirty fraction tumor control doses were performed in air breathing mice, under normal blood flow conditions (two fractions/day). The results of these studies have been previously published. For studies under uniformly (clamp) hypoxic conditions, tumors arising from the same transplantation were randomized into single or fractionated dose protocols. For estimation of the fractionated TCD50 under hypoxic conditions, tumors were exposed to six 5.4 Gy fractions (∼ 2 Gy equivalent under air), followed by graded 'top-up' dose irradiation for determination of the TCD50; the time interval between doses was 6-9 hours. The single dose equivalent of the six 5.4 Gy doses was used to calculate an extrapolated 30 fraction hypoxic TCD50. Results: Fractionation substantially increased the dose required for tumor control in 4 of the 5 tumors investigated. For these 4 tumors

  8. Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

    DEFF Research Database (Denmark)

    Bertelsen, Anders; Lorenzen, Ebbe L; Brink, Carsten

    2011-01-01

    ) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency......Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR...

  9. Glycosylation intermediates studied using low temperature 1H- and 19F-DOSY NMR

    DEFF Research Database (Denmark)

    Qiao, Yan; Ge, Wenzhi; Jia, Lingyu

    2016-01-01

    Low temperature 1H- and 19F-DOSY have been used for analyzing reactive intermediates in glycosylation reactions, where a glycosyl trichloroacetimidate donor has been activated using different catalysts. The DOSY protocols have been optimized for low temperature experiments and provided new insight...

  10. Comparison of the dose results in whole body and thyroid caused by {sup 131} I using the software AIDE, DOSINT and ACCUSCAN; Comparacion de los resultados de dosis en cuerpo entero y tiroides causada por {sup 131} I utilizando los softwares AIDE, DOSINT y ACCUSCAN

    Energy Technology Data Exchange (ETDEWEB)

    Quintero P, E.; Alfaro L, M.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: eqp@nuclear.inin.mx

    2006-07-01

    Due to the sharp incorporation of 3.7 MBq of {sup 131} I via oral for a patient, with the purpose of obtaining a thyroid gamma gram, it makes later a pursuit on to carry out the calculation of effective dose committed using the software AIDE, DOSINT and Accuscan that possesses the National Institute of Nuclear Research (ININ) and to compare the results of these. For this study it was carried out a pursuit of the biokinetic behavior of the radioisotope in the patient's body, measuring the activity with a whole-body counter of vertical sweeping, Canberra, model Accuscan Canberra trademark. The calibration of the system it was carried out using a RMC-II Canberra trademark phantom. The patient was accounted to different intervals of time starting from April 5 up to June 30, 2005. The Accuscan II program Canberra trademark, it was acquired with the whole-body system in 1992 by the ININ. The DOSINT program was elaborated by the National Commission of Nuclear Safety and Safeguards of Mexico and proportionate to the ININ in 2000. So much the DOSINT program as the Accuscan are based on the ICRP-26/30. The AIDE program was provided by the IAEA through the project IAEA-ARCAL-RLA/9/049-LXXVII - Harmonization of procedures of internal dosimetry in 2005. This program is based on the ICRP-78. The present activity in the urine was measured later starting from the third day of the incorporation of {sup 131} I to different intervals of time until the 87 th day. The measurements were carried out using a gamma spectrometer with a Ge Hp detector and beryllium window, with 27.4% of relative efficiency and graduate armor-plating. The calibration of the system it was carried out using a multi nuclides pattern packed in Marinelli geometry of 0.5 L, prepared by the Laboratory of Radioactive Patterns (LPR) of the INlN starting from a certified solution. (Author)

  11. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC)

    Energy Technology Data Exchange (ETDEWEB)

    Gerard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, Francois; Aletti, Pierre [Research Center for Automatic Control (CRAN), Nancy University, CNRS, 54516 Vandoeuvre-les-Nancy (France); Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France) and DOSIsoft SA, 94230 Cachan (France); Research Laboratory for Innovative Processes (ERPI), Nancy University, EA 3767, 5400 Nancy Cedex (France); Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France); DOSIsoft SA, 94230 Cachan (France); Research Center for Automatic Control (CRAN), Nancy University, CNRS, 54516 Vandoeuvre-les-Nancy, France and Department of Medical Physics, Alexis Vautrin Cancer Center, 54511 Vandoeuvre-les-Nancy Cedex (France)

    2009-04-15

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center ({+-}4% of deviation between the calculated and measured doses) by calculating a control process capability (C{sub pc}) index. The C{sub pc} index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should

  12. A comprehensive analysis of the IMRT dose delivery process using statistical process control (SPC).

    Science.gov (United States)

    Gérard, Karine; Grandhaye, Jean-Pierre; Marchesi, Vincent; Kafrouni, Hanna; Husson, François; Aletti, Pierre

    2009-04-01

    The aim of this study is to introduce tools to improve the security of each IMRT patient treatment by determining action levels for the dose delivery process. To achieve this, the patient-specific quality control results performed with an ionization chamber--and which characterize the dose delivery process--have been retrospectively analyzed using a method borrowed from industry: Statistical process control (SPC). The latter consisted in fulfilling four principal well-structured steps. The authors first quantified the short-term variability of ionization chamber measurements regarding the clinical tolerances used in the cancer center (+/- 4% of deviation between the calculated and measured doses) by calculating a control process capability (C(pc)) index. The C(pc) index was found superior to 4, which implies that the observed variability of the dose delivery process is not biased by the short-term variability of the measurement. Then, the authors demonstrated using a normality test that the quality control results could be approximated by a normal distribution with two parameters (mean and standard deviation). Finally, the authors used two complementary tools--control charts and performance indices--to thoroughly analyze the IMRT dose delivery process. Control charts aim at monitoring the process over time using statistical control limits to distinguish random (natural) variations from significant changes in the process, whereas performance indices aim at quantifying the ability of the process to produce data that are within the clinical tolerances, at a precise moment. The authors retrospectively showed that the analysis of three selected control charts (individual value, moving-range, and EWMA control charts) allowed efficient drift detection of the dose delivery process for prostate and head-and-neck treatments before the quality controls were outside the clinical tolerances. Therefore, when analyzed in real time, during quality controls, they should improve the

  13. Efficacy of low-dose lansoprazole in the treatment of non-erosive gastroesophageal reflux disease: Influence of infection by Helicobacter pylori Eficacia de lansoprazol a dosis bajas en el tratamiento de la enfermedad por reflujo gastroesofágico no erosiva: Influencia de la infección por Helicobacter pylori

    Directory of Open Access Journals (Sweden)

    M. Castro Fernández

    2006-03-01

    Full Text Available Introduction: proton pump inhibitors (PPIs are the most effective drugs to cure peptic esophagitis and control the symptoms of gastroesophageal reflux disease (GERD. In most patients with GERD esophagitis is not detected by endoscopy, which represents GERD with a negative endoscopy or non-erosive reflux disease (NERD. The influence of infection by H. pylori in the evolution of GERD is controversial since a protective action is identified by some studies, but not all. We conducted a clinical trial to assess the efficacy of lansoprazole 15 mg/day in the initial control of NERD symptoms, and as a secondary endpoint the impact of H. pylori infection on response to treatment. Patients and methods: a pilot, single-center clinical trial was conducted -single-blind regarding the experimental medication (unknown to patients, and double-blind regarding the information concerning H. pylori infection. Sixty (60 patients with NERD were initially included, who had suffered from daytime or nocturnal heartburn for 1-2 days in each of the last two weeks. Nine patients were excluded for failing to comply with the study protocol. The 51 remaining patients, 35 women and 16 men, with a mean age of 49 years, comprised the per protocol analysis population. Patients received treatment for two weeks with a capsule of the study medication (15 mg/day of lansoprazole, with daily controls on the presence and severity of daytime and nocturnal heartburn. Treatment was considered effective when, upon completion, patients referred a maximum of one episode of mild heartburn as defined in the protocol, or answered the following question in the affirmative: "Does the medication you are receiving satisfactorily control the symptoms of your disease?". During diagnostic endoscopy we obtained biopsies of the gastric body and antrum to investigate infection by H. pylori by means of a urease test. Treatment efficacy was assessed with no patients or doctors responsible for the study

  14. DOSIS & DOSIS 3D: radiation measurements with the DOSTEL instruments onboard the Columbus Laboratory of the ISS in the years 2009-2016

    Czech Academy of Sciences Publication Activity Database

    Berger, T.; Burmeister, S.; Matthiae, D.; Przybyla, B.; Reitz, G.; Bilski, P.; Hajek, M.; Sihver, L.; Szabó, J.; Ambrožová, Iva; Vanhavere, F.; Gaza, R.; Semones, E.; Yukihara, E. G.; Benton, E.; Uchihori, Y.; Kodaira, S.; Kitamura, H.; Böhme, M.

    2017-01-01

    Roč. 7, MAR (2017), č. článku A8. ISSN 2115-7251 R&D Projects: GA ČR GJ15-16622Y Institutional support: RVO:61389005 Keywords : International Space Station * Columbus * space radiation * DOSTEL * DOSIS 3D Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics, space science) Impact factor: 2.446, year: 2016

  15. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques; Evaluacion en muestras biologicas de radionucleidos emisores beta mediante espectrometria de centelleo en fase liquida. Aplicaciones al estudio de dosis internas en tecnicas de investigacion de biologia molecular y celular

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-07-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs.

  16. Déficit de vitamina B12 asociado con altas dosis de metformina en adultos mayores diabéticos

    OpenAIRE

    Hugo Sánchez; Dominique Masferrer; Lydia Lera; Estrella Arancibia; Bárbara Ángel; Cecilia Albala

    2014-01-01

    Introducción: El objetivo del estudio es estimar si el déficit de B12 se asocia con el uso de la metformina en adultos mayores (AM) diabéticos. Métodos: Estudio de casos y controles en AM diabéticos. Los casos (n = 137) se definieron como AM con B12 221 pmol/L. Se definieron 4 categorías de uso de metformina: no usuarios, ≤ 850 mg/día; > 850 y < 2.550 mg/día; ≥ 2.550 mg/día. Se consideró altas dosis de metformina (≥ 2.550 mg/día). Se cal...

  17. Dose measurements in controlled area and laboratory of TRIGA IPR-R1 reactor

    International Nuclear Information System (INIS)

    Maretti Junior, Fausto; Alvarenga, Frederico Ladeia

    2005-01-01

    The workers doses in exposure areas to the radiation are so important for a Radioprotection Quality Program, as well as to guarantee the workers safety. For that it is necessary to raise the doses in the radiation areas, to obtain the accumulated dose in certain procedures for detailed studies. Several risings were accomplished to obtain the radiation levels in the areas where the workers are exposed due the operation of a research nuclear reactor and in the radioisotopes manipulation laboratories of a nuclear institute. The radiation levels and doses can be observed through graphs in the dependences of the Controlled Area 1 (AC-1) and the Reactor Laboratory. Those limits are in according of the CNEN-NE-3.01 work limits rules. The conclusion of the work allowed to demonstrate that the Laboratory of the Reactor and AC-1, have booth an effective radiological program with efficient operational practices that contributes with low doses to the workers. (author)

  18. Dose measurements in controlled area of TRIGA IPR-R1 reactor

    International Nuclear Information System (INIS)

    Alvarenga, F.L.; Junior, F.M.

    2005-01-01

    The workers doses in exposure areas to the radiation are so important for a Radioprotection Quality Program, as well as to guarantee the workers safety. For that it is necessary to raise the doses in the radiation areas, to obtain the accumulated dose in certain procedures for detailed studies. Several risings were accomplished to obtain the radiation levels in the areas where the workers are exposed due the operation of a research nuclear reactor and in the radioisotopes manipulation laboratories of a nuclear institute. The radiation levels and doses can be observed through graphs in the dependences of the Controlled Area 1 (AC-1) and the Reactor Laboratory. Those limits are in according of the CNEN-NE-3.01 work limits rules. The conclusion of the work allowed to demonstrate that the Laboratory of the Reactor and AC-1, have booth an effective radiological program with efficient operational practices that contributes with low doses to the workers

  19. A two isocenter IMRT technique with a controlled junction dose for long volume targets

    International Nuclear Information System (INIS)

    Zeng, G G; Heaton, R K; Catton, C N; Chung, P W; O'Sullivan, B; Lau, M; Parent, A; Jaffray, D A

    2007-01-01

    Most IMRT techniques have been designed to treat targets smaller than the field size of conventional linac accelerators. In order to overcome the field size restrictions in applying IMRT, we developed a two isocenter IMRT technique to treat long volume targets. The technique exploits an extended dose gradient throughout a junction region of 4-6 cm to minimize the impact of field match errors on a junction dose and manipulates the inverse planning and IMRT segments to fill in the dose gradient and achieve dose uniformity. Techniques for abutting both conventional fields with IMRT ('Static + IMRT') and IMRT fields ('IMRT + IMRT') using two separate isocenters have been developed. Five long volume sarcoma cases have been planned in Pinnacle (Philips, Madison, USA) using Elekta Synergy and Varian 2100EX linacs; two of the cases were clinically treated with this technique. Advantages were demonstrated with well-controlled junction target uniformity and tolerance to setup uncertainties. The junction target dose heterogeneity was controlled at a level of ±5%; for 3 mm setup errors at the field edges, the junction target dose changed less than 5% and the dose sparing to organs at risk (OARs) was maintained. Film measurements confirmed the treatment planning results

  20. Practice of radiation dose control for tech-modification items in Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zhang Yong; Chen Zhongyu; Xu Hongming; Fan Liguang; Jiang Jianqi; Bu Weidong

    2006-01-01

    In order to improve the safety and reliability of nuclear power plant operation, many tech-modifications related to system or equipment have been completed since operation in Qinshan NPP. this paper introduces radiation dose control for mainly tech-modifications items related to radiation, including radiation protection optimization measures and experience in aspects of item planning, program writing, process control, etc. (authors)

  1. Effect of quality control implementation on image quality of radiographic films and irradiation doses to patients

    International Nuclear Information System (INIS)

    Cheng Yuxi; Zhou Qipu; Ge Lijuan; Hou Changsong; Qi Xuesong; Yue Baorong; Wang Zuoling; Wei Kedao

    1999-01-01

    Objective: To study the changes in the image quality of radiographic films and the irradiation doses to patients after quality control (QC) implementation. Methods: The entrance surface doses (ESD) to patients measured with TLD and the image quality of radiographic films were evaluated on the basis of CEC image quality criteria. Results: The ESD to patients were significantly reduced after QC implementation (P 0.05), but the post-QC image quality was significantly improved in chest PA, lumbar spine AP and pelvis AP(P0.01 or P<0.05). Conclusion: Significantly reduced irradiation dose with improved image quality can be obtained by QC implementation

  2. Surface dose characterisation of the Varian Ir-192 HDR conical surface applicator set with a vertically orientated source

    Energy Technology Data Exchange (ETDEWEB)

    Buchauer, Konrad; Henke, Guido; Schiefer, Hans; Plasswilm, Ludwig [Kantonsspital St. Gallen, Department of Radiation Oncology, St. Gallen (Switzerland)

    2014-12-15

    Conical surface applicators with an Ir-192 high-dose-rate brachytherapy source are a common modality for the treatment of non-melanomatous skin cancer with high tumour control rates. Surface dose characterisation of the Varian Varisource GammaMed+ IX afterloader vertical type surface applicators is performed two dimensionally using high-resolution film dosimetry. The focus of this study was to determine if Varian surface applicators with a vertical source suffer from the dose distribution irregularities reported for comparable applicators. Our goal was to evaluate if the irregularities found affected treatment and dose output verification procedures. Ionisation chamber-based verification of applicator output was established according to guidelines provided by the manufacturer. For additional measurement of surface dose Gafchromic EBT3 film dosimetry was used. The term ''therapeutic dose'' was defined as 85 % of the prescribed dose level. For the 10 different applicator inserts evaluated, cold spots were observed. Mean cold spot size was 2.0 mm x 3.6 mm (± 0.6 mm). The cold spots were dosimetrically well below 85 % of the prescribed dose. The cold spot was situated 2.2 mm (1.4-2.7 mm) unilaterally from the central axis and caused general asymmetry in the dose profiles intersecting the cold spot area. A source tilt of approximately 8 (± 1 ) was determined for the source used for irradiation. A central underdosed area exceeding 15 % of the prescribed dose has not been previously reported. Source tilt was observed and found to affect clinical use and possibly treatment outcome in applicators using a vertically arranged source. Surface applicators with a vertically orientated source were subject to dose irregularities that could impact on chamber-based applicator output verification procedures. We recommend film dosimetry-backed applicator commissioning to avoid systematic errors. (orig.) [German] Konische Oberflaechenapplikatoren sind ein

  3. Control and monitoring of doses to patients in a team of digital mammography

    International Nuclear Information System (INIS)

    Agulla Otero, M.; Torres Cabrera, R.; Hernando Gonzalez, I.

    2013-01-01

    In recent years is widespread use of imaging devices digital mammography. One of the advantages associated with this scanning is the ability to access a large amount of information contained in the headwaters of own digital images. The exploitation of this information allows the calculation of doses received by patients. This paper describes the methodology employed for this purpose and are presented the results of the control and monitoring of doses given in a digital mammography equipment. (Author)

  4. Effect of time, dose and fractionation on local control of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lee, Anne W.M.; Chan, David K.K.; Poon, Y.F.; Foo, William; Law, Stephen C.K.; O, S.K.; Tung, Stewart Y.; Fowler, Jack F.; Chappell, Rick

    1995-01-01

    To study the effect of radiation factors on local control of nasopharyngeal carcinoma, 1008 patients with similarly staged T1N0-3M0 disease (Ho's classification) were retrospectively analyzed. All patients were treated by megavoltage irradiation alone using the same technique. Four different fractionation schedules had been used sequentially during 1976-1985: with total dose ranging from 45.6 to 60 Gy and fractional dose from 2.5 to 4.2 Gy. The median overall time was 39 days (range = 38-75 days). Both for the whole series and 763 patients with nodal control, total dose was the most important radiation factor. The hazard of local failure decreased by 9% per additional Gy (p < 0.01). Biological equivalents expressed in terms of Biologically Effective Dose or Nominal Standard Dose also showed strong correlation. Fractional dose had no significant impact. The effect of overall treatment time was insignificant for the whole series, but almost reached statistical significance for those with nodal control (p = 0.06). Further study is required for elucidation, as 85% of patients completed treatment within a very narrow range (38-42 days), and the possible hazard is clinically too significant to be ignored

  5. Characterization of Brønsted acid-base complexes by ¹⁹F DOSY.

    Science.gov (United States)

    Subramanian, Hariharaputhiran; Jasperse, Craig P; Sibi, Mukund P

    2015-03-20

    A (19)F DOSY protocol for the determination of formula weights for acid-base complexes in solution has been developed. (19)F internal standards were chosen and were used to evaluate the formula weights of complexes in solution using simple diffusion coefficient (D)-formula weight (FW) analysis. This method has potential applications in characterization of reactive intermediates in catalytic asymmetric reactions.

  6. Quality control of diagnostic radiology to reduce absorbed dose of patients in Iran

    International Nuclear Information System (INIS)

    Aghahadi, Bahman.

    1996-01-01

    In order to reduce absorbed dose, to increase the image quality and to reduce the numbers of rejected films various quality control parameters were applied to X ray machines. These parameter are Kilo Volt peak, Milli Ampere, Exposure Time Focal Film Distance, Inherent Filters, Additional Filters Half Value Layer, Processor Condition, Cassettes. To evaluate and to apply these parameters in diagnostic radiological centers, ten hospitals were selected and a total number of 12 X ray machines were kept under quality control program. Considering different kinds of diagnostic radiology examination and to compare the dose before and after implementation of a quality control program, two kinds of examinations include in chest and abdomen examinations were considered. For each X ray machine, ten patients and for all selected centers, 120 patients were selected for chest examination and 120 patients for abdomen examinations; before and after implementation of quality control program, a total of 480 patients were selected randomly to be controlled. Base on different examinations carried out, it was concluded that both exposure conditions and general situations in radiological centers were not acceptable. The dosimetry results show that the average ski dose for chest and abdomen examinations were 0.28 m Gy and 4.23 Gy respectively. Before implementation of quality control step to reduce the surface skin dose, quality control parameters were applied and the exposure conditions were imposed. On average the absorbed doses for chest and abdomen examination were decreased to 79% and 61% respectively after the implementation of the program. From dose reduction point of view, the results of a part of this project which made by co-operation of International Atomic Energy Agency showed that Iran acquired the first grade for chest examination and second grade for abdomen examination. Base on the results obtained, the number of patients under chest and abdomen examination were 4041588 and

  7. Optimization of foramsulfuron doses for post-emergence weed control in maize (Zea mays L.)

    Energy Technology Data Exchange (ETDEWEB)

    Pannacci, E.

    2016-11-01

    Four field experiments were carried out from 2011 to 2014 in order to evaluate the effects of foramsulfuron, applied at the recommended (60.8 g a.i./ha) and reduced doses (1/3 and 2/3), on the efficacy against several of the most important weeds in maize. For each “year-weed” combination, dose-response curves were applied to estimate the dose of foramsulfuron required to obtain 90% and 95% weed control (ED90 and ED95). Foramsulfuron phytotoxicity on maize and crop yield were assessed. Foramsulfuron at 1/3 of the recommended dose (20.3 g a.i./ha) provided 95% efficacy against redroot pigweed (Amaranthus retroflexus L.), green foxtail (Setaria viridis (L.) Beauv.), wild mustard (Sinapis arvensis L.) and black nightshade (Solanum nigrum L.). Velvetleaf (Abutilon theophrasti Medik.), common lambsquarters (Chenopodium album L.) and barnyardgrass (Echinochloa crus-galli (L.) Beauv.) were satisfactorily controlled (95% weed efficacy) with ED95 ranged from 20 to 50 g/ha of foramsulfuron (about from 1/3 to 5/6 of the recommended dose) depending on growth stage. The recommended dose was effective against pale smartweed (Polygonum lapathifolium L.) at 2-4 true leaves (12-14 BBCH scale), but this dose did not kill plants larger than 2-4 true leaves. The ranking among weed species based on their susceptibility to foramsulfuron was: redroot pigweed = green foxtail = wild mustard = black nightshade > velvetleaf = common lambsquarters = barnyardgrass > pale smartweed. Dose of foramsulfuron can be reduced below recommended dose depending on weed species and growth stage. Foramsulfuron showed a good crop selectivity and had no negative effect on maize yield. (Author)

  8. Radiation dose control in the mining of high grade uranium ores

    International Nuclear Information System (INIS)

    Webster, S.T.; Brown, L.D.

    1996-01-01

    The control of radiation doses received by uranium miners is an unusually complex procedure, as three separate components of their total effective dose may be significant and may have to be evaluated separately. Apart from external and internal doses evaluated in the usual way, it is also necessary to evaluate the inhalation dose from radon progeny separately. Although this essentially forms part of the internal dose received, it is not evaluated in the conventional way since the associated dose equivalent must be derived from conversion factors based on epidemiological studies, instead of by the usual approach of calculating the dose to tissue from the inhaled activity and multiplying this by a recognized conversion factor to derive a whole body effective dose. Historically the traditional unit used for monitoring the concentration of radon progeny in a workplace is the Working Level (WL), this is now defined as a concentration such that the potential alpha emission from all the short lived progeny present in the sample will total 1.3 x 108 MeV per m 3 . The corresponding unit of exposure is the Working Level Month (WLM) and is the exposure that would be received by a reference man working in such an atmosphere for a standard working month lasting 170 hours. Unfortunately the relationship between exposures, measured in WLM, and the conventional radiation dose to the target tissues is complex and calculated values depend greatly upon the assumptions made in the lung model that must be used. Risks are therefore still controlled by limiting exposures in WLM on the basis of epidemiological studies of lung cancer incidence among miners employed at a time when the magnitude of the risk was not fully appreciated, and cancer incidence was high enough to permit reasonably accurate risk estimates to be derived directly from exposures in WLM. (author)

  9. Offsite dose calculation manual guidance: Standard radiological effluent controls for boiling water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-- 01, which allows Radiological Effluent Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft form for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. 11 tabs

  10. Recuperación del epitelio germinal masculino de ratones tratados con dosis única de Busulfán

    Directory of Open Access Journals (Sweden)

    Luis Guzmán

    2013-05-01

    Full Text Available Busulfán es un agente alquilante bifuncional tipo-éster, que interfiere con la replicación del ADN. Dosis elevadas de este compuesto son aplicadas antes de los transplantes de médula ósea y de células germinales, sin embargo no han sido cuantificados el daño ni la recuperación del sistema reproductor. Para cuantificar la recuperación del efecto en la espermatogénesis, se usaron ratones de la cepa Balb C, a los que se les inyectó Busulfán intraperitonealmente, 40 mg/kg de peso corporal, y se evaluó el peso testicular y la concentración espermática en cola de epidídimo, a los 30, 54 y 72 días y se realizaron cortes histológicos de testículo. Los resultados fueron analizados con la prueba U Mann-Whitney p>0.05. A los 30 días el peso testicular, la concentración espermática y el diámetro de los túbulos seminíferos presentaron una drástica reducción del 77,8%, 97,9% y 34,3% respectivamente, comparados con el grupo control. A los 54 días, el peso testicular y el diámetro testicular muestran una recuperación del 70%. A los 72 días, la recuperación es completa en los parámetros evaluados. Por lo tanto, Busulfán aplicado en una sola dosis afecta significativamente la espermatogénesis en el ratón y se logra la recuperación completa en dos ciclos espermáticos.

  11. Intracavitary brachytherapy significantly enhances local control of early T-stage nasopharyngeal carcinoma: the existence of a dose-tumor-control relationship above conventional tumoricidal dose

    International Nuclear Information System (INIS)

    Teo, Peter Man Lung; Leung, Sing Fai; Lee, Wai Yee; Zee, Benny

    2000-01-01

    the chronic radiation complications, with the exception of chronic radiation nasopharyngeal ulceration/necrosis which occurred in 10 patients in Group A and 1 patient in Group B. Headache (n = 4) and foul smell (n = 8) consequential to ulceration/necrosis were mild and manageable by conservative means. A significant dose-tumor-control relationship existed when local failure was studied as a function of the total physical dose or the total biological equivalent dose (linear quadratic equation, α/β = 10) uncorrected for tumor repopulation during the time course of the radiotherapy. Conclusions: Supplementing ERT which delivered tumoricidal dose (uncorrected BED-10 ≥75 Gy), ICT significantly enhanced ultimate local control and avoided the necessity for morbid salvage treatments in early T-stage (T1/T2 nasal infiltration) NPC. The slight increase in chronic radiation ulceration/necrosis after ICT was acceptable with mild and manageable symptoms. Other late complications were not increased. A significant dose-tumor-control relationship exists above the conventional tumoricidal dose level

  12. Effects of different doses of skt-b vibrio probiotic bacteria addition on survival and growth rate of tiger shrimp (Penaeus monodon larva

    Directory of Open Access Journals (Sweden)

    . Widanarni

    2010-01-01

    Full Text Available Probiotic bacteria has been widely used as biocontrol agents in tiger shrimp hatcheries.  Vibrio SKT-b is one of the probiotic bacteria candidates that could suppressed the growth of pathogenic bacteria Vibrio harveyi and could increase survival rate of tiger shrimp larva. This experiment was carried out to study the effects of probiotic bacteria SKT-b Vibrio addition at different doses on survival and growth rate of tiger shrimp larva.  Experiment was conducted with five treatments and three replications, consisted of SKT-b Vibrio probiotic bacteria addition at the doses of 103 CFU/ml, 104 CFU/ml, 105 CFU/ml, and 106 CFU/ml and control (0 CFU/ml.  Results showed that optimum dose of probiotic bacteria for tiger shrimp was 104 CFU/ml with a survival rate of 94.67%. However, the addition of probiotic bacteria at this particular dose did not significantly increase shrimp growth rate as compared with control. Key words: Probiotic bacteria, SKT-b Vibrio, doses, tiger shrimp larva   ABSTRAK Bakteri probiotik telah banyak digunakan sebagai agen biokontrol dalam pembenihan udang windu.  Vibrio SKT-b merupakan salah satu jenis bakteri kandidat probiotik yang telah diuji dapat menekan pertumbuhan bakteri patogen Vibrio harveyi dan dapat meningkatkan kelangsungan hidup larva udang windu.  Tujuan dari penelitian ini adalah untuk mengetahui pengaruh pemberian bakteri probiotik Vibrio SKT-b dengan dosis yang berbeda terhadap kelangsungan hidup dan pertumbuhan larva udang windu. Penelitian ini dilakukan dalam 5 perlakuan dengan masing-masing 3 ulangan, yaitu penambahan bakteri probiotik Vibrio SKT-b dengan dosis 103 CFU/ml, 104 CFU/ml, 105 CFU/ml, dan 106 CFU/ml dan kontrol (0 CFU/ml.  Hasil penelitian menunjukkan bahwa dosis optimal untuk larva udang windu adalah 104 CFU/ml dengan nilai kelangsungan hidup 94,67%. Namun, pemberian bakteri probiotik tersebut belum menghasilkan pertumbuhan yang berbeda nyata dengan kontrol. Kata kunci: Bakteri probiotik

  13. Dose to population as a metric in the design of optimised exposure control in digital mammography

    International Nuclear Information System (INIS)

    Klausz, R.; Shramchenko, N.

    2005-01-01

    This paper describes a methods for automatic optimisation of parameter (AOP) in digital mammography systems. Using a model of the image chain, contrast to noise ratio (CNR) and average glandular dose (AGD) are computed for possible X-ray parameters and breast types. The optimisation process consists of the determination of the operating points providing the lowest possible AGD for each CNR level and breast type. The proposed metric for the dose used in the design of an AOP mode is the resulting dose to the population, computed by averaging the AGD values over the distribution of breast types in the population. This method has been applied to the automatic exposure control of new digital mammography equipment. Breast thickness and composition are estimated from a low dose pre-exposure and used to index tables containing sets of optimised operating points. The resulting average dose to the population ranges from a level comparable to state-of-the-art screen/film mammography to a reduction by a factor of two. Using this method, both CNR and dose are kept under control for all breast types, taking into consideration both individual and collective risk. (authors)

  14. The Physician Tendency in Stereotactic Radiosurgery Dose Prescription in Benign Intracranial Tumor at dr. Cipto Mangunkusumo National Hospital, Jakarta

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-09-01

    Full Text Available Stereotactic radiosurgery (SRS is one of the treatment modalities for benign intra-cranial tumor, especiallyfor the tumor located next to the critical neural structure. The prescribed dose for radiosurgery depends onthe maximal tumor diameter and surrounding normal tissue tolerance dose. This cross sectional study wasconducted to evaluate the physician’s tendency in radiosurgery dose prescription. We observed treatmentplanning data of 32 patients with benign intra-cranial tumor, which had been treated with SRS at Dr. CiptoMangunkusumo National Hospital in 2009-2010. The peripheral dose, organ at risk (OAR dose limitiationand maximum tumor diameter were recorded. We compared our SRS dose with dose limitation, whichallowed safer dosing based on maximal tumor diameter perspective and the nearest OAR dose constraint.From maximal tumor diameter perspective, we prescribed mean±SD radiosurgery doses, which were11.63±2.21Gy, 10.21±1.29Gy and 9.88±1.07Gy for the tumor size ≤2cm, 2.01-3cm and 3,01-4cm respectively.Our radiosurgery dose was the lowest than dose limitation based on the nearest OAR perspective, followedby maximal tumor diameter perspective. It was concluded that radiosurgery dose had the tendency to beinfluenced by surrounding healthy tissue tolerance rather than maximal tumor diameter. Keywords: stereotactic, radiosurgery, benign tumor, dose.   Kecenderungan Dokter dalam Menentukan Dosis StereotacticRadiosurgery untuk Tumor Jinak Intrakranial diRSUP Nasional dr. Cipto Mangunkusumo, Jakarta Abstrak Stereotactic radiosurgery (SRS merupakan salah satu modalitas pengobatan tumor jinak intra-kranialterutama untuk tumor yang berdekatan dengan struktur saraf penting. Penentuan dosis pada radiosurgerytergantung pada diameter tumor maksimal dan dosis toleransi jaringan sehat sekitarnya. Penelitian inidilakukan untuk mengevaluasi kecenderungan dokter dalam menentukan dosis radiosurgery. Penelitian crosssectional ini mengevaluasi data

  15. Respuesta de Leucaena leucocephala cv. Perú a la aplicación de diferentes dosis de MicoFert agrícola

    Directory of Open Access Journals (Sweden)

    L Ojeda

    Full Text Available Se realizó una investigación en la Empresa Pecuaria El Tablón (Cumanayagua, provincia Cienfuegos, Cuba, con el objetivo de evaluar el efecto que ejerce la aplicación de diferentes dosis de MicoFert agrícola sobre la producción de materia seca (MS y el contenido de fósforo foliar en Leucaena leucocephala cv. Perú. El diseño fue de bloques al azar, con seis tratamientos y tres réplicas. Los tratamientos estuvieron constituidos por cuatro dosis de MicoFert (250, 500, 750 y 1 000 g/m-1, una variante a razón de 25 kg de N ha-1, y el control. El experimento tuvo una duración de dos años; se realizaron cuatro cortes por año, con una frecuencia de 90 días, a una altura de 25 cm sobre el suelo. La aplicación de MicoFert agrícola incrementó el rendimiento de MS entre 13 y 40 %, de forma proporcional a las dosis aplicadas, respecto al control. El rendimiento más alto de MS (18,44 t ha-1 se obtuvo con la aplicación de nitrógeno, y difirió significativamente del resto de los tratamientos. Fue evidente el efecto que ejerció la inoculación con el biofertilizante en el contenido de fósforo foliar, el cual mostró diferencias significativas entre las variantes con MicoFert y el control. La colonización de raicillas por los hongos micorrízicos arbusculares (HMA fue proporcional al incremento de las dosis de biofertilizante, con valores de 34, 38, 44 y 49 %, respectivamente. La fertilización con nitrógeno y el control presentaron 28 y 26 % de colonización micorrízica, lo que indicó la presencia de HMA nativos.

  16. Efficacy of Single-Dose and Triple-Dose Albendazole and Mebendazole against Soil-Transmitted Helminths and Taenia spp.: A Randomized Controlled Trial

    Science.gov (United States)

    Steinmann, Peter; Utzinger, Jürg; Du, Zun-Wei; Jiang, Jin-Yong; Chen, Jia-Xu; Hattendorf, Jan; Zhou, Hui; Zhou, Xiao-Nong

    2011-01-01

    Background The control of soil-transmitted helminth (STH) infections currently relies on the large-scale administration of single-dose oral albendazole or mebendazole. However, these treatment regimens have limited efficacy against hookworm and Trichuris trichiura in terms of cure rates (CR), whereas fecal egg reduction rates (ERR) are generally high for all common STH species. We compared the efficacy of single-dose versus triple-dose treatment against hookworm and other STHs in a community-based randomized controlled trial in the People's Republic of China. Methodology/Principal findings The hookworm CR and fecal ERR were assessed in 314 individuals aged ≥5 years who submitted two stool samples before and 3–4 weeks after administration of single-dose oral albendazole (400 mg) or mebendazole (500 mg) or triple-dose albendazole (3×400 mg over 3 consecutive days) or mebendazole (3×500 mg over 3 consecutive days). Efficacy against T. trichiura, Ascaris lumbricoides, and Taenia spp. was also assessed. Albendazole cured significantly more hookworm infections than mebendazole in both treatment regimens (single dose: respective CRs 69% (95% confidence interval [CI]: 55–81%) and 29% (95% CI: 20–45%); triple dose: respective CRs 92% (95% CI: 81–98%) and 54% (95% CI: 46–71%)). ERRs followed the same pattern (single dose: 97% versus 84%; triple dose: 99.7% versus 96%). Triple-dose regimens outperformed single doses against T. trichiura; three doses of mebendazole – the most efficacious treatment tested – cured 71% (95% CI: 57–82%). Both single and triple doses of either drug were highly efficacious against A. lumbricoides (CR: 93–97%; ERR: all >99.9%). Triple dose regimens cured all Taenia spp. infections, whereas single dose applications cured only half of them. Conclusions/Significance Single-dose oral albendazole is more efficacious against hookworm than mebendazole. To achieve high CRs against both hookworm and T. trichiura, triple-dose regimens are

  17. Control of moderate-to-severe asthma with randomized ciclesonide doses of 160, 320 and 640 μg/day

    DEFF Research Database (Denmark)

    Pedersen, Søren E.; Prasad, Niyati; Goehring, Udo Michael

    2017-01-01

    Background: The inhaled corticosteroid (ICS) ciclesonide (Cic), controls asthma symptoms in the majority of patients at the recommended dose of 160 μg/day. However, the relationship between the level of asthma control and increasing doses of Cic is unknown. This study investigated whether long-te...... additional effect. Patients who experience more than one exacerbation per year may benefit from higher doses; however, further studies are necessary to confirm this. All Cic doses were well tolerated....

  18. X-ray conditions and response characteristics of automatic dose control in cinematography

    International Nuclear Information System (INIS)

    Arai, Hiroaki

    1997-01-01

    X-ray characteristics including subject thickness (copper plate), tube voltage, tube current and irradiation time were measured at stability, with an automatic dose control x-ray generator for cineangiography. Regardless of subject thickness, it is possible that the energy input to the x-ray tube in one frame may be decreased. The automatic control response was measured after rapid fluctuation in subject thickness. Two inverter-type x-ray generators with different automatic control units were studied. The older control unit changes exposure dose by tube voltage and tube current, while the newer one changes exposure dose by tube voltage, tube current and irradiation time. The maximum rate of change in tube voltage is greater with the newer control unit. In addition, the actual tube current response of the newer control unit in increasing nominal value is faster than the older one. In the new control unit, for each pulse, irradiation is cut off by means of a signal that the exposure has reached the proper value. Thus given the same differential in subject thickness, the newer control unit resumed stability faster than the older one. (author)

  19. X-ray conditions and response characteristics of automatic dose control in cinematography

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Hiroaki [Cardiovascular Institute Hospital, Tokyo (Japan)

    1997-11-01

    X-ray characteristics including subject thickness (copper plate), tube voltage, tube current and irradiation time were measured at stability, with an automatic dose control x-ray generator for cineangiography. Regardless of subject thickness, it is possible that the energy input to the x-ray tube in one frame may be decreased. The automatic control response was measured after rapid fluctuation in subject thickness. Two inverter-type x-ray generators with different automatic control units were studied. The older control unit changes exposure dose by tube voltage and tube current, while the newer one changes exposure dose by tube voltage, tube current and irradiation time. The maximum rate of change in tube voltage is greater with the newer control unit. In addition, the actual tube current response of the newer control unit in increasing nominal value is faster than the older one. In the new control unit, for each pulse, irradiation is cut off by means of a signal that the exposure has reached the proper value. Thus given the same differential in subject thickness, the newer control unit resumed stability faster than the older one. (author)

  20. Measurement of local dose rates in controlled areas of nuclear power plants. Version 6/85

    International Nuclear Information System (INIS)

    1985-01-01

    Local dose rate measurements according to this regulation, serve the following purposes: Development of preventive measures for radiation protection with respect to maintenance and modifications in controlled areas, e.g. determination of individual measures for personnel protection, development of flow charts and dose rate estimates; monitoring of the personnel's location of activity within the controlled area, including determination of time-dependence of local dose rates and determination of immediate radiation protection measures required; limitation and identification of controlled areas. Such measurements are performed to ensure that the principles of radiation protection as stated in Art. 28 (1) of the Radiation Protection Ordinance with respect to external radiation exposure of the personnel, and the requirements of Art. 61 (1) of the Radiation Protection Ordinance relating to controlled areas are met and the limitation and identification of controlled areas as prescribed in Art 57 (1) of the Radiation Protection Ordinance can be performed. They are not used to determine body doses as per Art. 63 of the Radiation Protection Ordinance. (orig./HP) [de

  1. Performance of an automatic dose control system for CT. Specifications and basic phantom tests

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, H.D. [Wissenschaft und Technik fuer die Radiolgoe, Dr. HD Nagel, Buchholz (Germany); Stumpp, P.; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2011-01-15

    Purpose: To assess the performance and to provide more detailed insight into the characteristics and limitations of devices for automatic dose control (ADC) in CT. Materials and Methods: A comprehensive study on DoseRight 2.0, the ADC system provided by Philips for its Brilliance CT scanners, was conducted. Phantom tests were carried out on a 64-slice scanner (Brilliance 64) using assorted quality control (QC) phantoms that allowed verification of the basic specifications. If feasible, the findings were verified by model calculations based on known specifications. Results: For all tests, the dose reductions and modulation characteristics fully met the values expected from the specifications. Adverse effects due to increased image noise were only moderate as a result of the 'adequate noise system' design that employs comparatively gentle modulation, and the additional use of adaptive filtration. Conclusion: Simple tests with QC phantoms allow evaluation of the most relevant characteristics of devices for ADC in CT. (orig.)

  2. Respon Imun Itik Bali terhadap Berbagai Dosis Vaksin Avian Influenza H5N1

    Directory of Open Access Journals (Sweden)

    Ida Bagus Kade Suardana

    2009-09-01

    Full Text Available A study was carried out to investigate the immune response of Bali ducks against various doses ofAvian Influenza H5N1 vaccine. The study was carried out using a complete Random-Split in Time researchdesign as many as 40 of Bali ducks of 3 months age were kept separately in 4 groups. The ducks werevaccinated twice in two week interval with AI H5N1 vaccine of 0 (as negative control, 1/2, 1, and 2 doses.Sera were collected one day before first vaccination, then every week until three weeks after the secondvaccination. All sera were tested by hemaglutination inhibition (HI test. The result shows that antibodylevel with double dose was significantly higher than single dose, half dose, and negative control (P<0.01.However antibody level in ducks vaccinated with single and half dose did not show any significant difference(P > 0.05.

  3. Low doses of ionizing radiation: Biological effects and regulatory control. Contributed papers

    International Nuclear Information System (INIS)

    1997-11-01

    The International Atomic Energy Agency and the World Health Organization, in cooperation with the United Nations Scientific Committee on the Effects of Atomic Radiation, organized an international conference on Low Doses of Ionizing Radiation: Biological Effects and Regulatory Control, held in seville, Spain, from 17 to 21 November 1997. This technical document contains concise papers submitted to the conference

  4. Low doses of ionizing radiation: Biological effects and regulatory control. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    The International Atomic Energy Agency and the World Health Organization, in cooperation with the United Nations Scientific Committee on the Effects of Atomic Radiation, organized an international conference on Low Doses of Ionizing Radiation: Biological Effects and Regulatory Control, held in seville, Spain, from 17 to 21 November 1997. This technical document contains concise papers submitted to the conference. Refs, figs, tabs.

  5. Phantoms for quality control procedures in digital breast tomosynthesis: dose assessment

    NARCIS (Netherlands)

    Bouwman, R. W.; Diaz, O.; van Engen, R. E.; Young, K. C.; den Heeten, G. J.; Broeders, M. J. M.; Veldkamp, W. J. H.; Dance, D. R.

    2013-01-01

    The recent introduction of digital breast tomosynthesis into clinical practice requires quality control procedures. In this study we have investigated whether the assessment of the average glandular dose for modelled standard breasts can be performed using a combination of polymethyl methacrylate

  6. Results of dose control and measurement plans applied for SPEAR3 commissioning year (FY04)

    Energy Technology Data Exchange (ETDEWEB)

    Khater, Hesham [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)]. E-mail: khater1@llnl.gov; Liu, James [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Prinz, Alyssa [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Allan, Jim [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Rokni, Sayed [Radiation Protection Department, Stanford Linear Accelerator Center (SLAC), 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2006-12-15

    Dose control and measurement plans for the SPEAR3 Booster and storage ring have taken place during the SPEAR3 commissioning. The initial commissioning period (SPEAR3 start-up) covered the time period from the beginning of November 2003 to the early part of March 2004. The period from the beginning of March to the beginning of August 2004 has been mostly dedicated to the scientific program. The initial commissioning period was characterized with frequent injection and significantly higher losses. In comparison, the scientific program period was characterized with more stable beam operation with limited number of injections per day and lower beam losses. Three types of dose measurements, passive, active and special measurements, were implemented around the SPEAR3 Booster and storage ring. Based on the expected radiation hazards, several dose control measures were adopted at several stages of the commissioning. In the early stages of commissioning, areas within 4.5 m from the walls of the Booster and storage ring were designated as radiation areas (RA). Areas outside RA were classified as radiologically controlled area (RCA). Access to these areas required less training than the RA. A monthly review of the accelerator operation conditions and radiation measurement results were used to determine the changes needed for the RA classification status and associated dose control measures.

  7. Controllable dose: the ICRP discussion paper does not go far enough

    International Nuclear Information System (INIS)

    Carter, M.W.

    2000-01-01

    The current ICRP recommendations and the associated dosimetry have confused the public, lawyers and politicians and have been the subject of dissension within the Health Physics Community. Currently recommended limits are different for occupational exposure, exposure of the public, exposure to radon in dwellings and exposure to radon in workplaces. Current recommendations do not cover exposure in accident situations. The recommended limits do not apply to natural background radiation exposures. This suggests that the unit of radiation dose is variable depending on the circumstances and that artificially produced radiation is more harmful than natural radiation. The use of collective dose and the LNT model has resulted, in the opinion of some, in waste of money spent in trying to reduce doses that may be already too small to produce detectable harm. The recent discussion papers (Clarke, 1998, Clarke 1999), introducing the concept of controllable dose, are a valuable starting point for changing and improving the basis on which regulations are made. It is the author's opinion that the discussion paper does not go far enough and that the confusion is largely the result of failing to separate the scientific aspects from the regulatory aspects of controlling radiation dose. Only by making such a separation can we provide understandable regulations without compromising scientific research into radiation risks. Copyright (2000) Australasian Radiation Protection Society Inc

  8. Quality-controlled dose reduction of full-leg radiography in patients with knee malalignment

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, Jost Karsten; Neumann, Regina; Stiller, Wolfram; Kauczor, Hans-Ulrich; Weber, Marc-Andre [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Stillfried, Eva von; Ewerbeck, Volker [University Hospital Heidelberg, Department of Orthopedic and Trauma Surgery, Heidelberg (Germany)

    2014-12-05

    Digital plain radiographs of the full leg are frequently performed examinations of children and young adults. Thus, the objective of this work was to reduce the radiation exposure dependent on specific indications, and to determine objective quality-control criteria to ensure accurate assessment. Institutional review board approval and informed consent of all participants were obtained. In this prospective, randomized controlled, blinded, two-armed single-center study, 288 evaluable patients underwent plain radiography of the full leg with standard and reduced doses. The evaluation of the plain radiographs was conducted using the following criteria: mechanical axis, leg length, and maturation of the epiphyseal plate. Two blinded radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more points or all criteria with 2 points, the radiograph was scored as ''not assessable''. The study was designed as a non-inferiority trial. Eleven (3.8 %) examined X-rays were scored as not assessable. The rate of non-assessable radiographs with 33 % reduced dose was significantly not inferior to the rate of non-assessable radiographs with standard dose. The evaluation of the quality criteria was dose independent. Full-leg plain radiography in patients with knee malalignment can be performed at 33 % reduced dose without loss of relevant diagnostic information. (orig.)

  9. CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study.

    Science.gov (United States)

    Greffier, Joël; Pereira, Fabricio; Macri, Francesco; Beregi, Jean-Paul; Larbi, Ahmed

    2016-04-01

    To evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR). Three anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom. The use of AEC produced a significant dose reduction (p<0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p<0.01) and reduced SNR and CNR (p<0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency. In chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. APLIKASI DOSIS FERMENTASI PROBIOTIK BERBEDA PADA BUDIDAYA UDANG VANAME (Litopenaeus vannamei POLA INTENSIF

    Directory of Open Access Journals (Sweden)

    Gunarto Gunarto

    2016-11-01

    Full Text Available Aplikasi dosis probiotik yang tepat menjadi satu di antara penentu utama dalam peningkatan produksi udang di tambak, karena berkaitan dengan kemampuannya mengurai limbah organik sisa pakan dan sisa metabolisme udang yang dibudidayakan. Penelitian bertujuan untuk mengetahui pengaruh penggunaan dosis fermentasi probiotik yang berbeda pada pertumbuhan, sintasan, produksi udang, nilai rasio konversi pakan, dan kualitas air tambak budidaya intensif udang vaname di tambak. Enam unit tambak masing-masing ukuran 4.000 m2 ditebari benur vaname PL-10 dengan padat tebar 50 ekor/m2. Pakan diberikan dengan dosis 2,5%-100% dari total biomassa udang dengan frekuensi 2–4 kali/hari selama pemeliharaan 105 hari. Tiga dosis berbeda dari aplikasi fermentasi probiotik komersial dijadikan perlakuan, yaitu A. 1 mg/L/minggu, B. 3 mg/L/minggu, dan C. 5 mg/L/minggu. Masing-masing perlakuan dengan dua ulangan. Aplikasi fermentasi probiotik di tambak dilakukan setiap minggu sekali dan dimulai seminggu sebelum tebar hingga mendekati waktu panen. Sampling pertumbuhan dan kualitas air (amoniak, nitrit, nitrat, fosfat, bahan organik total (BOT, klorofil-a, total bakteri Vibrio sp. dan total bakteri dilakukan setiap dua minggu sekali. Pengamatan fluktuasi oksigen terlarut di air tambak selama 24 jam dilakukan pada hari ke-43, 60, dan 90. Sintasan, produksi, dan nilai konversi pakan dihitung setelah udang dipanen. Untuk mengetahui pengaruh dari perlakuan, maka data yang diperoleh dianalisis menggunakan analisis varian pola Rancangan Acak Lengkap, dan dilanjutkan dengan uji BNT apabila terjadi perbedaan yang nyata. Berdasarkan hasil penelitian nampak bahwa dosis 5 mg/L fermentasi probiotik, mampu menghasilkan sintasan yang lebih baik dan juga efisien dalam pemanfaatan pakan, yang ditunjukkan dengan nilai Rasio Konversi Pakan lebih rendah apabila dibandingkan dengan nilai Rasio Konversi Pakan yang diperoleh pada dosis fermentasi probiotik 3 dan 1 mg/L, meskipun demikian

  11. Inhomogeneous dose escalation increases expected local control for NSCLC patients with lymph node involvement without increased mean lung dose

    DEFF Research Database (Denmark)

    Nielsen, Tine B; Hansen, Olfred; Schytte, Tine

    2014-01-01

    in mediastinum, and the thorax wall. The dose was escalated using a TCP model implemented into the planning system. The difference in TCP values between the homogeneous and inhomogeneous plans were evaluated using two different TCP models. RESULTS: Dose escalation was possible for all patients. TCP values based...... to the mediastinum were observed: 2.5 Gy for aorta, 4.4 Gy for the connective tissue, 1.6 Gy for the heart, and 2.6 Gy for trachea + bronchi. CONCLUSION: Increased target doses and TCP values using inhomogeneous dose distributions could be achieved for all patients, regardless of lymph node involvement, tumour stage...

  12. Quality control and patient dose from X-ray examinations in some hospitals in Estonia

    International Nuclear Information System (INIS)

    Servomaa, A.; Rannikko, S.; Parviainen, T.; Holmberg, P.; Kuus, E.; Mueuersepps, T.; Jaerv, V.

    1995-01-01

    Quality control measurements of X ray diagnostic units were carried out in four hospitals in Estonia. Measurements were focused on the unit's technical performance, on image quality and on patient dose and film processing. The main problems are in the areas of image receptors and film processing: image receptors are of low speed type causing high patient doses and manual film processing results in low contrast and high base plus fog. Spatial resolution, both in film imaging and in image intensifiers, is reasonably good. It is recommended that quality assurance programmes be established, that basic measuring equipment be acquired and personnel assigned to perform such measurements be trained. (Author)

  13. PENGARUH VARIASI DOSIS LARUTAN BUAH BELIMBING WULUH (Averrhoa bilimbi L.TERHADAP MORTALITAS LARVA NYAMUK Culex sp. SEBAGAI SUMBER BELAJAR BIOLOGI PADA MATERI INSEKTA

    Directory of Open Access Journals (Sweden)

    Bagas Rasid Sidik

    2015-11-01

    Full Text Available Control of larvae of Culex sp. can be done with larvicides. Larvicides used in an attempt to reduce the population of larvae in a breeding place or for termination of the chain of mosquito breeding. Insect repellent effective to kill mosquitoes, but that has not been come mosquito larvae will develop into mosquitoes. Insect repellent made from synthetic chemicals if used excessively will cause adverse effects to humans such as respiratory disorders, digestive, and the environment. The purpose of this study was to determine (1 Whether or not the effect of giving a solution of fruit starfruit (Averrhoa bilimbi, L. against Culex sp. mosquito larvae mortality, (2 determine the most appropriate dosage on mortality of larvae of mosquito Culex sp., (3 Compile the results of the research as a high school biology class X LKPS semester two. This study uses the method of experiment, the draft design used was completely randomized design Variety (CRD with the control (P0 and 4 treatments, namely P1: a dose of1/99 ml, P2: dose2/98 ml, P3: dose3/97 ml, and P4: a dose4/96 ml with 6 replicates each, the number of larvae 150 animals. Larva l sampling and testing conducted at Flores Street No. 19 Ganjar Supreme 14/2 City Metro. The test was analyzed using one-way Anava non-parametric Kruskall-Wallis test. The results of the analysis are obtained as follows: (1 There is a very significant influence on the administration of a solution of fruit starfruit (Averrhoa bilimbi, L. against Culex mosquito larvae mortality due to the α sp 0.05,   at α 0.01 in Chi-square table, (2 the mortality of larvae of Culex for 24 consecutive hour sare from lowest to highest mortality percentage is P0=0%, P1=60%, P2=83.33%, 83.33% =P3, andP4=86,66%. Based on the results of research and discussion we concluded that: (1 There is the effect of star fruit solution on mortality of larvae of Culex sp mosquitoes, with coefficientH=17.73>Chi-square value of7.81at α level of 0.05, 11, 3

  14. Results of film dosemeter control irradiations of German dose measurements services, 1969-1974

    International Nuclear Information System (INIS)

    Gummi, V.; Taubert, R.

    1976-01-01

    The dose measurement services of the FRG have been controlling themselves since 1961 by evaluating film dosimeters irradiated in the PTB under standard conditions. This control method is now embodied in a law by the second decree about the standardization of measuring instruments dt. 6th August 1975. During the time 1969-74 the PTB carried out more than 800 annual control irradiations of film dosimeters. In 30% of the cases the evaluation by the measuring services showed an errory higher than +50%/-30%. The dose measuring services partially diverge considerably concerning the distribution of evaluation errors. Particular difficulties seem to exist in the soft x-ray radiation with effective energies less than 30 keV, in the energy range about 100 keV, and in the evaluation of dosemeter irradiated with two different qualities of radiation (double irradiation). (orig.) [de

  15. Overcoming beta-agonist tolerance: high dose salbutamol and ipratropium bromide. Two randomised controlled trials

    Directory of Open Access Journals (Sweden)

    Haney Sarah

    2007-03-01

    Full Text Available Abstract Background Asthmatics treated with long-acting beta-agonists have a reduced bronchodilator response to moderate doses of inhaled short acting beta-agonists during acute bronchoconstriction. It is not known if the response to higher doses of nebulised beta-agonists or other bronchodilators is impaired. We assessed the effect of long-acting beta-agonist treatment on the response to 5 mg nebulised salbutamol and to ipratropium bromide. Methods Two double-blind, placebo-controlled, crossover studies of inhaled formoterol 12 μg twice daily in patients with asthma. High-dose salbutamol: 36 hours after the last dose of 1 week of formoterol or placebo treatment, 11 subjects inhaled methacholine to produce a 20% fall in FEV1. Salbutamol 5 mg was then administered via nebuliser and the FEV1 was monitored for 20 minutes. Ipratropium: 36 hours after the last dose of 1 week of formoterol or placebo treatment, 11 subjects inhaled 4.5% saline to produce a 20% fall in FEV1. Salbutamol 200 μg or ipratropium bromide 40 μg was then inhaled and the FEV1 was monitored for 30 minutes. Four study arms compared the response to each bronchodilator after formoterol and placebo. Analyses compared the area under the bronchodilator response curves, adjusting for changes in pre-challenge FEV1, dose of provocational agent and FEV1 fall during the challenge procedure. Results The response to nebulised salbutamol was 15% lower after formoterol therapy compared to placebo (95% confidence 5 to 25%, p = 0.008. The response to ipratropium was unchanged. Conclusion Long-acting beta-agonist treatment induces tolerance to the bronchodilator effect of beta-agonists, which is not overcome by higher dose nebulised salbutamol. However, the bronchodilator response to ipratropium bromide is unaffected.

  16. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, R.; McCarty, M. [Div. of Radiology, South Cleveland Hospital, South Tees Acute Hospitals NHS Trust, Marton Road, Middlesbrough, Cleveland (United Kingdom); McCallum, H.M. [Regional Medical Physics Dept., South Cleveland Hospital, Middlesbrough (United Kingdom); Montgomery, R. [Dept. of Orthopaedics, South Tees Hospitals NITS Trust, Middlesbrough (United Kingdom); Aszkenasy, M. [Tees and North East Yorkshire NHS Trust, West Lane Hospital, Middlesbrough (United Kingdom)

    2001-05-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  17. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy.

    Science.gov (United States)

    Waugh, R; McCallum, H M; McCarty, M; Montgomery, R; Aszkenasy, M

    2001-05-01

    An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83%, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving.

  18. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    International Nuclear Information System (INIS)

    Waugh, R.; McCarty, M.; McCallum, H.M.; Montgomery, R.; Aszkenasy, M.

    2001-01-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  19. Digital chest radiography: an update on modern technology, dose containment and control of image quality

    International Nuclear Information System (INIS)

    Schaefer-Prokop, Cornelia; Venema, Henk W.; Neitzel, Ulrich; Uffmann, Martin; Prokop, Mathias

    2008-01-01

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems. (orig.)

  20. Vitamin D production depends on ultraviolet-B dose but not on dose rate: a randomized controlled trial

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A

    2011-01-01

    Ultraviolet-B (UV-B) radiation increases serum vitamin D level expressed as 25-hydroxyvitamin D(3) (25(OH)D), but the dose-response relationship and the importance of dose rate is unclear. Of 172 fair-skinned persons screened for 25(OH)D, 55 with insufficient baseline 25(OH)D=50 nm (mean 31.2 nm...... exposed. Skin pigmentation and 25(OH)D were measured before and after the irradiations. The increase in 25(OH)D after UV-B exposure (adjusted for baseline 25(OH)D) was positively correlated with the UV-B dose (P=0.001; R(2) =0.176) but not to dose rate (1-20 min). 25(OH)D increased in response to four UV......-B treatments of 3 SED with 24.8 nm on average and 14.2 nm after four UV-B treatments of just 0.375 SED. In conclusion, the increase in 25(OH)D after UV-B exposure depends on the dose but not on the dose rate (1-20 min). Further, a significant increase in 25(OH)D was achieved with a very low UV-B dose....

  1. Pengaruh Pemberian Kascing (Bekas Cacing) dengan Dosis yang Berbeda dalam Kultur Skeletonema Costatum

    OpenAIRE

    Fauziah, Fauziah; Hatta, Muhammad

    2015-01-01

    Penelitian ini bertujuan untuk mengetahui dosis kascing yang baik pada Kultur sel Skeletonema costatum untuk menghasilkan kepadatan sel Skeletonema costatum yang optimal. Penelitian ini dilaksanakan pada tanggal 11 - 25 Desember 2013. Di Balai Budidaya Air Payau (BBAP) Ujoeng Batee, Kabupaten Aceh Besar, Provinsi Aceh. Metode penelitian yang digunakan adalah metode eksperiment dengan Rancangan Acak Lengkap (RAL) non faktorial yang terdiri dari 4 perlakuan dan 3 ulangan. Adapun perlakuan dalam...

  2. Irradiación de tabletas de polen: Estudio de dosis

    Directory of Open Access Journals (Sweden)

    Eloy Padrón Soler

    1995-08-01

    Full Text Available El polen constituye una fuente rica de nutrientes para el hombre; sin embargo, dado su origen los productos elaborados a partir de él suelen resultar de una inadecuada calidad higiénica, lo que los sitúa fuera de las especificaciones establecidas en el país, por lo que es necesario en estos casos la aplicación de un método de descontaminación adecuado. El presente trabjo tuvo por objetivo estudiar las posibilidades de radiodescontaminación de tabletas de polen 125 mg mediante la aplicación de diferentes niveles de dosis de radiaciones gamma (2-10 kGy. Se realizaron evaluaciones microbiológicas y fisicoquímicas pre y postratamiento y se encontró que 6 kGy como dosis mínima es la dosis adecuada de irradiación para lograr el objetivo propuesto.

  3. Offsite dose calculation manual guidance: Standard radiological effluent controls for pressurized water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-01, which allows Radiological Effect Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft from (NUREG-0471 and -0473) for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. Also included for completeness are: (1) radiological environmental monitoring program guidance previously which had been available as a Branch Technical Position (Rev. 1, November 1979); (2) existing ODCM guidance; and (3) a reproduction of generic Letter 89-01

  4. Analysis of the relationship between tumor dose inhomogeneity and local control in patients with skull base chordoma

    International Nuclear Information System (INIS)

    Terahara, Atsuro; Niemierko, Andrzej; Goitein, Michael; Finkelstein, Dianne; Hug, Eugen; Liebsch, Norbert; O'Farrell, Desmond; Lyons, Sue; Munzenrider, John

    1999-01-01

    Purpose: When irradiating a tumor that abuts or displaces any normal structures, the dose constraints to those structures (if lower than the prescribed dose) may cause dose inhomogeneity in the tumor volume at the tumor-critical structure interface. The low-dose region in the tumor volume may be one of the reasons for local failure. The aim of this study is to quantitate the effect of tumor dose inhomogeneity on local control and recurrence-free survival in patients with skull base chordoma. Methods and Materials: 132 patients with skull base chordoma were treated with combined photon and proton irradiation between 1978 and 1993. This study reviews 115 patients whose dose-volume data and follow-up data are available. The prescribed doses ranged from 66.6 Cobalt-Gray-Equivalent (CGE) to 79.2 CGE (median of 68.9 CGE). The dose to the optic structures (optic nerves and chiasma), the brain stem surface, and the brain stem center was limited to 60, 64, and 53 CGE, respectively. We used the dose-volume histogram data derived with the three-dimensional treatment planning system to evaluate several dose-volume parameters including the Equivalent Uniform Dose (EUD). We also analyzed several other patient and treatment factors in relation to local control and recurrence-free survival. Results: Local failure developed in 42 of 115 patients, with the actuarial local control rates at 5 and 10 years being 59% and 44%. Gender was a significant predictor for local control with the prognosis in males being significantly better than that in females (P 0.004, hazard ratio = 2.3). In a Cox univariate analysis, with stratification by gender, the significant predictors for local control (at the probability level of 0.05) were EUD, the target volume, the minimum dose, and the D 5cc dose. The prescribed dose, histology, age, the maximum dose, the mean dose, the median dose, the D 90% dose, and the overall treatment time were not significant factors. In a Cox multivariate analysis, the

  5. Analysis of dose rates received around the storage pool for irradiated control rods in a BWR nuclear power plant

    International Nuclear Information System (INIS)

    Rodenas, J.; Abarca, A.; Gallardo, S.

    2011-01-01

    BWR control rods are activated by neutron reactions in the reactor. The dose produced by this activity can affect workers in the area surrounding the storage pool, where activated rods are stored. Monte Carlo (MC) models for neutron activation and dose assessment around the storage pool have been developed and validated. In this work, the MC models are applied to verify the expected reduction of dose when the irradiated control rod is hanged in an inverted position into the pool.

  6. Stereotactic radiosurgery for newly diagnosed brain metastases. Comparison of three dose levels

    Energy Technology Data Exchange (ETDEWEB)

    Rades, Dirk [University of Luebeck, Department of Radiation Oncology, Luebeck (Germany); Hornung, Dagmar [University Medical Center Hamburg-Eppendorf, Department of Radiation Oncology, Hamburg (Germany); Blanck, Oliver [University of Luebeck, Department of Radiation Oncology, Luebeck (Germany); CyberKnife Center Northern Germany, Guestrow (Germany); Martens, Kristina [University of Luebeck, Department of Radiation Oncology, Luebeck (Germany); University of Luebeck, Center for Integrative Psychiatry, Luebeck (Germany); Khoa, Mai Trong [Hanoi Medical University, Department of Nuclear Medicine, Hanoi (Viet Nam); Bach Mai Hospital, Nuclear Medicine and Oncology Center, Hanoi (Viet Nam); Trang, Ngo Thuy [Bach Mai Hospital, Nuclear Medicine and Oncology Center, Hanoi (Viet Nam); Hueppe, Michael [University of Luebeck, Department of Anesthesiology, Luebeck (Germany); Terheyden, Patrick [University of Luebeck, Department of Dermatology, Luebeck (Germany); Gliemroth, Jan [University of Luebeck, Department of Neurosurgery, Luebeck (Germany); Schild, Steven E. [Mayo Clinic Scottsdale, Department of Radiation Oncology, Scottsdale (United States)

    2014-09-15

    Three doses were compared for local control of irradiated metastases, freedom from new brain metastases, and survival in patients receiving stereotactic radiosurgery (SRS) alone for one to three newly diagnosed brain metastases. In all, 134 patients were assigned to three groups according to the SRS dose given to the margins of the lesions: 13-16 Gy (n = 33), 18 Gy (n = 18), and 20 Gy (n = 83). Additional potential prognostic factors were evaluated: age (≤ 60 vs. > 60 years), gender, Karnofsky Performance Scale score (70-80 vs. 90-100), tumor type (non-small-cell lung cancer vs. melanoma vs. others), number of brain metastases (1 vs. 2-3), lesion size (< 15 vs. ≥ 15 mm), extracranial metastases (no vs. yes), RPA class (1 vs. 2), and interval of cancer diagnosis to SRS (≤ 24 vs. > 24 months). For 13-16 Gy, 18 Gy, and 20 Gy, the 1-year local control rates were 31, 65, and 79 %, respectively (p < 0.001). The SRS dose maintained significance on multivariate analysis (risk ratio: 2.25; 95 % confidence interval: 1.56-3.29; p < 0.001). On intergroup comparisons of local control, 20 Gy was superior to 13-16 Gy (p < 0.001) but not to 18 Gy (p = 0.12); 18 Gy showed a strong trend toward better local control when compared with 13-16 Gy (p = 0.059). Freedom from new brain metastases (p = 0.57) and survival (p = 0.15) were not associated with SRS dose in the univariate analysis. SRS doses of 18 Gy and 20 Gy resulted in better local control than 13-16 Gy. However, 20 Gy and 18 Gy must be compared again in a larger cohort of patients. Freedom from new brain metastases and survival were not associated with SRS dose. (orig.) [German] Drei Dosislevel bei der alleinigen stereotaktischen Radiochirurgie (SRS) von 1 bis 3 neu diagnostizierten Hirnmetastasen wurden hinsichtlich lokaler Kontrolle der bestrahlten Metastasen, Nichtauftreten neuer Hirnmetastasen und Gesamtueberleben verglichen. Nach der am Rand der Metastasen applizierten SRS-Dosis wurden 134 Patienten den Gruppen 13

  7. Study on Coagulant Dosing Control System of Micro Vortex Water Treatment

    Science.gov (United States)

    Fengping, Hu; Qi, Fan; Wenjie, Hu; Xizhen, He; Hongling, Dai

    2018-03-01

    In view of the characteristics of nonlinearity, large time delay and multi disturbance in the process of coagulant dosing in water treatment, it is difficult to control the dosage of coagulant. According to the four indexes of raw water quality parameters (raw water flow, turbidity, pH value) and turbidity of sedimentation tank, the micro vortex coagulation dosing control model is constructed based on BP neural network and GA. The forecast results of BP neural network model are ideal, and after the optimization of GA, the prediction accuracy of the model is partly improved. The prediction error of the optimized network is ±0.5 mg/L, and has a better performance than non-optimized network.

  8. Improving the quality control program for patient dose calibrator according to IEC 60580

    International Nuclear Information System (INIS)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque

    2013-01-01

    The objective of this work was to improve the program quality control of this equipment based on the International Standard IEC 60580 - Medical electrical equipment - Dose area product meters . The initial program was established following the recommendations of IEC 61674 quoting dosimeters with ionization chambers and / or semiconductor detectors used in diagnostic X-ray image, however, the IEC 60580 is referred specifically to gauges and KAP (kerma-area product) presents additional tests. Tests included: intrinsic relative error, repeatability, scanning resolution, settling time, restarting, float values, response time and spatial uniformity of response. As a rule, all measurements are within the range characteristic of equipment performance. Thus, the PDC (Patient Dose Calibrator) again shows a device with excellent functionality and reliability in characterization tests carried out to quality control as( for the test in clinical PKA meters

  9. Radiation dose to the patient and the radiologist while performing on chest computed tomography: a program of early diagnosis of lung cancer, biopsy and treatment simulation guided radiation oncologist breast cancer; Dosis de radiacion al paciente y al radiologo durante la realizacion de tomografia computarizada en torax: progrma de diagnostico precoz del cancer de pulmon, biopsia guiada y simulacion del tratamiento oncologo radioterapico del cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Pastor Sanchis, V.; Martinez Sanchez, J. M.; Palma Copete, J. D.; Crispin Contreras, V.; Casal Zamorano, E.; Dolores Alemany, V. de los; Gonzalez Perez, V.; Gimeno Olmo, J.; Guardino de la Flor, C.

    2011-07-01

    In this paper we determine the equivalent dose received by the operator and patient lung biopsies using thermoluminescence dosimeters, are established recommendations that this dose is as low as possible. It also reviews the acquisition protocols in both CT scans in early diagnosis program cited as the acquisition of CT for treatment planning dosimetric radiation oncologist in breast cancer.

  10. The influence of aspirin dose and glycemic control on platelet inhibition in patients with type 2 diabetes mellitus

    NARCIS (Netherlands)

    Lemkes, B. A.; Bahler, L.; Kamphuisen, P. W.; Stroobants, A. K.; van den Dool, E. J.; Hoekstra, J. B.; Nieuwland, R.; Gerdes, V. E.; Holleman, F.

    Background: Low-dose aspirin seems to offer no benefit in the primary prevention of cardiovascular disease in type 2 diabetes mellitus (DM2). The anti-platelet effect may be diminished by poor glycemic control or inadequate dosing of aspirin. Objectives: To study the effects of both glycemic control

  11. PERFORMA PERTUMBUHAN KRABLET KEPITING BAKAU, Scylla olivacea, YANG DIBERI PAKAN DENGAN DOSIS BERBEDA SELAMA PERIODE PENDEDERAN

    Directory of Open Access Journals (Sweden)

    Usman Usman

    2016-12-01

    Full Text Available Jumlah pemberian pakan yang tepat sangat penting dalam periode pendederan krablet kepiting bakau karena pada periode tersebut tingkat kanibalisme krablet sangat tinggi. Informasi dosis pemberian pakan pada krablet ini masih sangat kurang khususnya dengan penggunaan pakan buatan. Penelitian ini bertujuan mengevaluasi kinerja pertumbuhan dan sintasan krablet kepiting bakau yang diberi pakan buatan dengan dosis berbeda selama periode pendederan. Hewan uji yang digunakan adalah krablet kepiting bakau dengan bobot awal rata-rata 0,038 g dan lebar karapas awal rata-rata 3,25 mm. Krablet dipelihara dalam bak berukuran 1,0 m × 1,0 m × 0,5 m sebanyak sembilan unit, dengan kepadatan awal masing-masing 50 ekor/bak. Tiga level dosis pakan harian yang dicobakan yaitu: 20%, 30%, dan 40% dari biomassa dan diberikan pada pagi dan sore hari selama lima minggu. Hasil penelitian menunjukkan bahwa dua minggu pertama periode pendederan, pemberian dosis pakan 20% memiliki sintasan yang lebih rendah (P0,05 di antara perlakuan. Pada pendederan krablet kepiting bakau, dosis pemberian pakan harian sebaiknya sebanyak 30% pada dua minggu pertama hingga krablet berukuran 0,2-0,3 g (lebar karapas 8-10 mm, selanjutnya 20% pada minggu ke-3, 15% pada minggu ke-4, dan 10% pada minggu ke-5. Appropriate feeding rate applied during nursery of mud crab crablet is important due to high cannibalism occurred at this stage. The information on feeding rates for crablet during nursery is still limited, in particularly the used of artificial diet. This study aims to evaluate the growth performance and survival rate of mud crab crablet fed artificial feed at different feeding rates during the nursery. The crablets with average initial weight of 0.038 g and initial carapace width of 3.25 mm were used in this study. The crablets were stocked in nine tanks sizing of 1.0 m × 1.0 m × 0.5 m each, with the initial density of 50 crablets/tank. Three daily feeding rates were tested at 20%, 30

  12. System composition and operation of exposure dose registration and control system (Final report)

    International Nuclear Information System (INIS)

    1978-01-01

    Since November, 1976, the committee concerning the investigation of exposure dose registration and control system for employees in nuclear industries has discussed on the exposure dose registration and control system, issued the interim report (outline) in April, 1977, and continued to investigate the details organizing the working group. Here, the final report is presented. It describes first on the definition of the terms used and the basic concept of the exposure dose registration and control system, in which the name of that organization is decided as ''Central Registration Office for Radiation Works'', Radiation Influence Association, the foundational juridical person. Next, the works to be performed in the Center and nuclear energy enterprises are explained. The items concerning the business management at the time of practical execution are the major part of the report, and are over 22 items. These include the registration business, the official reporting business, inquiry and answer business about career, change and revision, and computer processing system. As the temporary measures for transfer ring to the new system, 10 items are also provided. Supplementary explanation of 9 important items is given in the appendix. (Wakatsuki, Y.)

  13. Dosis diagnóstica y umbral de resistencia de Lutzomyia evansi (Diptera: Psychodidae, a dos insecticidas utilizados en salud pública en Colombia: deltametrina y lambdacihalotrina

    Directory of Open Access Journals (Sweden)

    Caterine HENRIQUEZ

    2009-01-01

    Full Text Available Los insecticidas son una herramienta importante para el control de los insectos transmisores de microorganismos patógenos. El objetivo de este estudio fue determinar la dosis diagnóstica de deltametrina y lambdacihalotrina en el flebotomíneo Lutzomyia evansi (Núñez-Tovar, vector de Leishmania infantum en Colombia. Los insectos se recolectaron en la Estación Experimental de Fauna Silvestre de Colosó, Sucre, un área de reserva natural que no ha sido sometida a presión con insecticidas. Los bioensayos se realizaron en botellas de vidrio, siguiendo el método simplificado de determinación de resistencia del CDC. En los experimentos, se usaron hembras silvestres de L. evansi que fueron expuestas a diferentes concentraciones de los insecticidas por espacio de 80 minutos, tiempo de duración de la prueba. Los valores de dosis diagnóstica hallados fueron 0,00035% para lambdacihalotrina y 0,0007% para deltametrina, con un umbral de resistencia de diez minutos para ambos insecticidas, tiempo en el cual se alcanza una mortalidad del 100%. Los datos de tiempo-mortalidad indican que la lambdacihalotrina tiene un efecto letal sobre L. evansi en menor concentración que la deltametrina, mientras que la última fue menos tóxica.

  14. Safety margin in irradiation of colorectal liver metastases: assessment of the control dose of micrometastases

    Directory of Open Access Journals (Sweden)

    Seidensticker Max

    2010-03-01

    Full Text Available Abstract Backround Micrometastases of colorectal liver metastases are present in up to 50% of lesions. In this study we sought to determine the threshold dose for local control of occult micrometastases in patients undergoing CT (computed tomography-guided brachytherapy of colorectal liver metastases. Materials and methods Nineteen patients demonstrated 34 local tumor recurrences originating from micrometastases after CT-guided brachytherapy of 27 colorectal liver metastases. We considered a local tumor recurrence as originating from a micrometastasis if tumor regrowth occurred adjacent to a formerly irradiated lesion and the distance of the 3D isocenter of the new lesion was ≤ 23.5 mm from the previous tumor margin. Follow-up MRI was fused with the planning-CT and dosimetry data. Two reviewers independently indicated the dose exposure at the isocenter of the micrometastases. Statistical analysis included an analysis of variance (ANOVA using backward selection. 95% tolerance intervals with coverage of 87.5 and 75% of the data of the normal distribution were calculated. Results The median distance of the micrometastases to the margin of the originating colorectal metastases was 8.75 mm (1-21 mm. Dose exposure at the isocenter was 12.25 Gy (7-19.8 in median. We stratified according to the distance from the isocenter to the initial tumor margin: ≤ 9 mm, > 9-15 mm and > 15 mm. The median dose in the according isocenters was 13.18, 11.6 and 11.85 Gy. The threshold dose failing to prevent micrometastasis growth was sigificantly higher in a subgroup of lesions with ≤ 9 mm distance as compared to > 15 mm (13.18 vs 11.85 Gy. Adjuvant chemotherapy correlated with greater distance of micrometastasis growth to the tumor but not with the threshold dose. Conclusion To prevent loss of local tumor control by continuous growth of micrometastases a threshold dose of 15,4 Gy (single fraction should be delivered at a distance of 21 mm to the gross tumor

  15. Dose assessment method for control room habitability in accident condition in nuclear power plants

    International Nuclear Information System (INIS)

    Yang Dong; Tang Shaohua; Wang Jianhua

    2012-01-01

    Based on the NRC. technical requirements on NPP control room habitability assessment, and considering the characteristics of the improved second generation NPPs in China, this paper developed a complete dose assessment model for control room habitability. Contrasting to the existing model in China, this model is applicable for DBA and sever accident, and the short term atmospheric diffusion factor can be calculated using the combined wake mode. By considering the zoning of habitable area and the design characteristics of the ventilation system, the effects of un-filtrated air leakage from the building and the ventilation system on the assessment calculation can be considered. (authors)

  16. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    International Nuclear Information System (INIS)

    Lin, Pei-Jan Paul

    2009-01-01

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  17. Radiation protection philosophy and control of radiation doses from nuclear waste disposal

    International Nuclear Information System (INIS)

    Bryant, P.M.

    1981-01-01

    The author has reviewed the concurrent developments in each of the three decades from 1950 to the present day in radiation protection philosophy and in the control of radioactive waste disposals, with particular reference to the control of radiation doses to the public from disposals from nuclear installations. In addition, the author has summarised the OECD Nuclear Energy Agency's optimisation study which is a generic analysis of the quantitative factors pertinent to the management of tritium, carbon-14, krypton-85 and iodine-129, identified as being the radionuclides in fuel cycle effluents likely to be significant in the radiation exposure of large populations. (author)

  18. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan Paul [Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2009-05-15

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  19. Dose effects of dietary phytosterols on cholesterol metabolism: a controlled feeding study.

    Science.gov (United States)

    Racette, Susan B; Lin, Xiaobo; Lefevre, Michael; Spearie, Catherine Anderson; Most, Marlene M; Ma, Lina; Ostlund, Richard E

    2010-01-01

    Phytosterol supplementation of 2 g/d is recommended by the National Cholesterol Education Program to reduce LDL cholesterol. However, the effects of different intakes of phytosterol on cholesterol metabolism are uncertain. We evaluated the effects of 3 phytosterol intakes on whole-body cholesterol metabolism. In this placebo-controlled, crossover feeding trial, 18 adults received a phytosterol-deficient diet (50 mg phytosterols/2000 kcal) plus beverages supplemented w