WorldWideScience

Sample records for doppler ultrasound scan

  1. Doppler ultrasound scan during normal gestation: umbilical circulation

    International Nuclear Information System (INIS)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J.

    2002-01-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs

  2. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  3. Comparison of CT scan and colour flow doppler ultrasound in detecting venous tumour thrombous in renal cell carcinoma

    International Nuclear Information System (INIS)

    Khan, A.R.; Anwar, K.

    2008-01-01

    Renal cell carcinoma has marked tendency to spread into renal vein, inferior vena cava and right side of heart. Extension of tumour thrombus into these veins will alter the surgical approach. We have compared the CT scan with Colour flow Doppler ultrasound in detecting venous tumour thrombus in renal vein and inferior vena cava. This cross-sectional study included 30 adult patients presenting with renal tumour. Patients of either gender were included in the study. Non probability convenience sampling was used. All patients underwent colour flow Doppler ultrasound and CT scan with contrast to asses the renal vein and inferior vena cava. The results were confirmed by intra operative findings and histopathology. The data was analyzed using SPSS version 12. Out of 30 patients, 20 (66%) were males and 10 (34%) female. The tumour was predominantly on the right side (60%), as was renal venous tumour thrombus (44%). Inferior vena cava was involved in 4 cases predominantly due to right sided tumours. The sensitivity of Doppler ultrasound in detecting renal venous tumour thrombus (88% on right and 100% on left side) was higher than CT scan (63% on right and 60% on left side). Doppler ultrasound was also superior to CT scan in detecting vena caval thrombus. The overall sensitivity of Doppler sonography was higher than CT scan in detecting tumour extension into renal veins and inferior vena cava. Therefore, it can be used as a complementary tool in equivocal cases. (author)

  4. The doppler ultrasound. La ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Contreras Cecilia, E.; Lozano Setien, E.; Hernandez Montero, J.; Ganado Diaz, T.; Jorquera Moya, M.; Blasco Pascual, E. (Hospital Universitario San Carlos. Madrid (Spain))

    1994-01-01

    The discovery and development of Doppler ultrasound has had a great influence on Medical practice since it allows the noninvasive study of vascular pathology, both arterial and venous, as well as the flow patterns of the different parenchyma. This article deals with the principles, limitations and interpretation of the Doppler signal, as well as the different Doppler ultrasound systems routinely employed in Medicine.

  5. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  6. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  7. Acute pyelonephritis in pediatric age: comparative study between power Doppler ultrasound scan and DMSA; Pielonefritis aguda en la edad pediatrica: estudio comparative entre la ecografiapower-Doppler y el DMSA

    Energy Technology Data Exchange (ETDEWEB)

    Muro, M. D.; Sanguesa, C.; Otero, M. C.; Piqueras, A. I.; Lloret, M. T. [Hospital Infantil Universitario La Fe. Valencia (Spain)

    2002-07-01

    To evaluate the usefulness of power Doppler (PD) Ultrasound Scan in the study of acute pyelonephritis (APN). To compare ultrasound scan results with those obtained with renal gammagraphy (DMSA). To relate the findings to the clinical criteria and to determine the presence of vesicoureteral reflux (VUR) in the serial micturition cystography (SMC). Prospective study of 92 patients (ages between 1 month and 10 years) with suspected clinical PNA. All children were initially subjected to PD ultrasound scan and DMSA. Those under 3 years old were also subjected to SMC for the study of VUR. PNA in the PD ultrasound scan was manifested by decrease in vascularisation and in the DMSA by decrease in caption in the affected zones. 87 renal units (RU) with PNA foci were detected. Conformity between the PD ultrasound scan and DMSA was 157 RU (92%): 52 positives, 22 negatives with PNA and 83 normal RU. The sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 80% and 85%, respectively. Mode B ultrasound scan and PD can replace DMSA in the initial study of PPNA. It is non-invasive, simple, economical and just as reliable as DMSA in expert hands. it can also postpone by up to 6 months the need to perform DMSA for detection of permanent renal damage. (Author) 22 refs.

  8. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...... on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...

  9. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  10. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  11. Colour Doppler ultrasound of the penis

    International Nuclear Information System (INIS)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S.

    2003-01-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis

  12. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    –0.97). Conclusion Color Doppler ultrasound is an effective noninvasive method for the initial diagnosis of impalpable testes and for planning its subsequent management. Keywords: color Doppler ultrasound, laparoscopy, nonpalpable testes ...

  13. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were us...

  14. with Ultrasound Color Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2012-01-01

    Full Text Available Color Doppler imaging (CDI can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture.

  15. Experience in scrotal doppler ultrasound in a Nigerian tertiary hospital

    African Journals Online (AJOL)

    Background: Scrotal diseases can be diagnosed with clinical examination or radiological imaging. The use of ultrasound with Doppler application has several advantages in the evaluation of this sensitive and private organ. Objectives: To document the pattern of Doppler ultrasound findings in patients presenting with ...

  16. Accuracy of doppler ultrasound in diagnosis of endometrial carcinoma

    International Nuclear Information System (INIS)

    Batool, S.; Raza, S.; Manzur, S.

    2013-01-01

    Objective: To determine the accuracy of Doppler ultrasound in the diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding while taking histopathological findings as the gold standard. Methods: The cross-sectional study was done at the Department of Radiology, Bahawal Victoria Hospital, Bahawalpur, from April 1 to September 30, 2009, and comprised 128 patients above 50 years of age having history of post-menopausal bleeding and who were referred to the department. Name, age and hospital registration number were recorded on a proforma. Doppler ultrasound was performed and endometrial thickness and uterine artery resistive index were recorded on transabdominal ultrasonography. Patients with endometrial thickness of more than 5mm and uterine artery resistive index of less than 0.7 were considered to be having endometrial carcinoma. Histopathology findings were also recorded using the hospital registration number of the patient. The findings of Doppler ultrasound scan were validated with the findings of histopathology. Results: Of the 128 patients, 48 (37.5%) were between the ages of 51 and 55 years; 46 (35.93%) were in the 56-60 age group; and 34 (26.57%) were over 65 years. On the basis of Doppler ultrasound findings, 106 (82.8%) patients were diagnosed as having endometrial carcinoma, while 22 (17.19%) were declared negative. Ultrasonography results were compared with histopathology findings. The percentages of true positive, true negative, false positive and false negative were calculated. There were 103 (80.47%) true positive; 12 (9.37%) false positive; 10 (7.81%) true negative; and 3 (2.35%) false negative. Specificity, sensitivity, positive predictive value and negative predictive value were found to be 97.16%, 76%, 89.56% and 76.92% respectively. Conclusion: The use of Doppler ultrasonography in non-invasive diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding was quite useful with good

  17. Routine diagnostic antenatal ultrasound scan: knowledge and ...

    African Journals Online (AJOL)

    ... the management of the pregnant woman. Majority of our patients are aware of ultrasound scan service and many of them have actually used the service before. This should make compliance to doctors' request for ultrasound scan easy and patients should derive the full benefit of Ultrasound scan especially in pregnancy.

  18. Colour Doppler ultrasound in the management of a case of cranial arteritis.

    OpenAIRE

    Williamson, T H; Baxter, G; Paul, R; Dutton, G N

    1992-01-01

    Colour Doppler ultrasound allows simultaneous B scan and Doppler imaging and can be employed to determine the velocity of blood flow in the vasculature of the eye and orbit. We describe a case of cranial arteritis (giant cell arteritis) in which serial velocimetry recordings were obtained. At one stage in the disease process no blood flow was detectable in the orbit despite previously reliable recordings. This coincided with a deterioration of the clinical state of the patient as signified by...

  19. Transcranial Doppler ultrasound and cerebral angiography - alternative or complementary

    International Nuclear Information System (INIS)

    Bockenheimer, S.; Lorey, N.

    1985-01-01

    Transcranial Doppler ultrasound is a noninvasive method of recording the flow velocity of larger intracranial vessels. The impact on diagnosis of cerebravascular occlusive disease is not yet evaluated. We present 15 patients, age range 39-73 years, who suffered from completed stroke. The findings of transcranial Doppler ultrasound and of cerebral angiography are presented. The value of both methods in treatment strategy is discussed. (orig.) [de

  20. Diagnostic sensitivity and specificity of Doppler ultrasound in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Terslev, L.; Recke, P. von der; Torp-Pedersen, S.

    2008-01-01

    Objective. To evaluate the sensitivity and specificity of Doppler ultrasound (DUS) in diagnosing arthritis in the wrist and hands, and, if possible, to define a cutoff level for our ultrasound measures for inflammation, resistive index (RI), and color fraction. Methods. Using DUS, 88 patients...

  1. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  2. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  3. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  4. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  5. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  6. Analysis of 50 cases of traumatic retinal detachment diagnosed by color Doppler ultrasound and two-dimensional ultrasound

    Directory of Open Access Journals (Sweden)

    Guo-An Liu

    2014-07-01

    Full Text Available AIM: To evaluate the value of color Doppler ultrasound in the diagnosis of traumatic retinal detachment. METHODS:All 50 cases(56 eyesof suspicious traumatic retinal detachment from January to June in 2013 were enrolled in this study. All first received the two-dimensional ultrasound, then the color Doppler ultrasound, finally, these results were compared with the results of surgery. RESULTS:All 56 eyes were observed intravitreal abnormal spots by the two-dimensional ultrasound, and 39 eyes were observed color blood signal by the color Doppler ultrasound. Forty eyes were approved retinal detachment by surgery. CONCLUSION: It is better to display the intravitreal abnormal spots and color blood signal by the color Doppler ultrasound than by the two-dimensional ultrasound, so there is important clinical significance of the color Doppler ultrasound in the diagnosis of traumatic retinal detachment.

  7. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...... access blood flow measured before and after every procedure. Two methods, catheter-based thermodilution and Doppler ultrasound, were compared to the reference method of ultrasound dilution. Catheter-based thermodilution and Doppler ultrasound were performed during the endovascular procedures while flow...

  8. Meckel's Diverticulum: Doppler Ultrasound and the tree sign

    International Nuclear Information System (INIS)

    Archila, Cesar Augusto

    2007-01-01

    Mecker's diverticulum is considered the most frequent congenital anomaly of the gastrointestinal tract, affecting 2% of the popular population. Failure of the obliteration of the viteline duct in the embryogenesis age causes this alteration. Abdominal pain, hemorrhage and obstruction are the clinical expression of this entity. The case of a young 16 years old male, with acute abdomen in whom the ultrasound Doppler color tool made the diagnosis of Meckel's diverticulitis is reported. The tree sign: an ultrasonographic sign is illustrated

  9. Choroid metastasis of papillary thyroid carcinoma. Color doppler ultrasound study

    International Nuclear Information System (INIS)

    Ganado, T.; Torre, S. de la; Contreras, E.; Hernandez, J.

    1997-01-01

    The most common causes of intraocular metastases are breast and lung cancers, although many other neoplasms can metastasize to the eye. Most of the metastases are located in the posterior pole and the choroid is more often involved than the retina. We present a case of a choroidal metastasis from a papillary carcinoma of the thyroid, associated with a massive subretinal hemorrhage. Findings with color Doppler ultrasound are emphasized. (Author) 9 refs

  10. From a formal training program in musculoskeletal ultrasound (MSUS) to a high reproducibility for Doppler ultrasound in rheumatoid arthritis.

    Science.gov (United States)

    Villota, Orlando; Diaz, Mario; Ceron, Carmen; Moller, Ingrid; Naredo, Esperanza; Saaibi, Diego Luis

    2017-07-28

    To assess the intra- and inter-observer reliability of ultrasound (US) in scoring B-mode, Doppler synovitis and combined B-mode and Doppler synovitis scores in different peripheral joints of rheumatoid arthritis (RA) patients. Four rheumatologists with a formal training in musculoskeletal US (MSKUS) particularly focus on definitions and scoring synovitis on B-mode and Doppler mode participated in a patient-based reliability exercise on 16 active RA patients. The four rheumatologists independently and consecutively performed a B-mode and power Doppler (PD) US assessment of 7 joints of each patient in two rounds in a blinded fashion. Each joint was semi quantitatively scored from 0 to 3 for B-mode synovitis (BS), Doppler synovitis (DS), and combined B-mode/Doppler synovitis (CS). Intraobserver reliability was assessed by Cohen's κ. Interobserver reliability was assessed by unweight Light's κ. The mean prevalence of synovitis on B-mode was 83% of joints; scores ranging from grade 1 in 18% of joints, to grade 3 in 33%. In 55% of joints synovial PD signal was detected and the distribution of scores range from 14% of joints for grade 3, to 26% for grade 2. After a total of 448 joints scanned with 896 adquired images our intraobserver and interobserver reliability was good to excellent for most of the joints. Formal, structured and continuous training in musculoskeletal ultrasound would bring a good to excellent reproducibility in rheumatological hands with a high reliability in real time acquisition BS, DS and CS modalities for scoring synovitis in patients with active rheumatoid arthritis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  12. Blood and Wall Signal Simulator for Doppler Ultrasound Signal Analysis Algorithm Development

    National Research Council Canada - National Science Library

    Fish, P

    2001-01-01

    Doppler ultrasound instruments, used for the detection and monitoring of vascular disease, require a means of separating the large, low frequency Doppler signal from the vessel wall from the signal...

  13. Automatic Segmentation of Vessels in In-Vivo Ultrasound Scans

    DEFF Research Database (Denmark)

    Tamimi-Sarnikowski, Philip; Brink-Kjær, Andreas; Moshavegh, Ramin

    2017-01-01

    was evaluated empirically and applied to a dataset of in-vivo 1770 images recorded from 8 healthy subjects. The segmentation results were compared to manual delineation performed by two experienced users. The results showed a sensitivity and specificity of 90.41 ± 11.2 % and 97.93 ± 5.7 % (mean ± standard......Ultrasound has become highly popular to monitor atherosclerosis, by scanning the carotid artery. The screening involves measuring the thickness of the vessel wall and diameter of the lumen. An automatic segmentation of the vessel lumen, can enable the determination of lumen diameter. This paper...... presents a fully automatic segmentation algorithm, for robustly segmenting the vessel lumen in longitudinal B-mode ultrasound images. The automatic segmentation is performed using a combination of B-mode and power Doppler images. The proposed algorithm includes a series of preprocessing steps, and performs...

  14. Gray scale and Doppler ultrasound in placenta accreta: Optimization of ultrasound signs

    Directory of Open Access Journals (Sweden)

    Mohamed Shawky

    2016-09-01

    Conclusion: Ultrasound and Doppler examinations of placenta have signs highly suggestive of placenta accreta due to high sensitivity and specificity with placental lacunae of turbulent flow and retro-placental myometrial thickness ⩽1 mm are of the highest specificity.

  15. A New Approach to Teaching Human Cardiovascular Physiology Using Doppler Ultrasound.

    Science.gov (United States)

    Looker, T.

    1985-01-01

    Explains the principles of the Doppler ultrasound technique and reviews its potential applications to the teaching of cardiovascular physiology. Identifies the instrumentation needed for this technique; provides examples and illustrations of the waveforms from the ultrasound blood velocimeter. (ML)

  16. Doppler and ultrasound methods for diagnosis.

    Science.gov (United States)

    Strandness, D E

    2000-09-01

    With the availability of ultrasonic duplex scanning we now have a method of safely screening those patients who may be thought to have renal artery stenosis as the basis for hypertension or renal failure. Modern instrumentation combined with an experienced technologist makes this a reasonable and accurate screening test. One of its major advantages is that it can be used for repeat studies to document the outcome of any form of intervention designed to remove or bypass areas of stenosis. We no longer need to wonder if a reconstruction has been successful or not. Another great advantage is its role in documenting both the degree of narrowing and its effect on kidney size. It is now known, because of information obtained with this technology, that high-grade renal artery stenoses are accompanied by a decrease in kidney size. It is also possible to document disease progression with atherosclerotic involvement of the renal arteries. With more widespread use of this method, we will be able to obtain useful information on how renal artery disease should be treated and monitored.

  17. Intrahepatic portosystemic venous shunts: diagnosis by Doppler ultrasound; Cortocircuitos venosos portosistemicos intrahepaticos: diagnostico mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Garofano, M. P.; Medina, A.; Lopez, G.; Garrido, C. [Hospital Universitario Virgen de las Nieves. Granada (Spain)

    2001-07-01

    Intrahepatic portosystemic venous shunts are venous vascular lesions that allow intrahepatic portal vessels to communicate with hepatic veins. They may present in patients with portal hypertension or b discovered incidentally; it is considered that the latter may be congenital or acquired. A noninvasive methods. Doppler ultrasound aids in the diagnosis of these anomalous communications by providing images of the vessels and the direction, velocity and volume of the blood flow through the shunt. We present four cases of intrahepatic portosystemic venous shunt. (Author) 8 refs.

  18. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  19. Settings and artefacts relevant for Doppler ultrasound in large vessel vasculitis

    DEFF Research Database (Denmark)

    Terslev, L; Diamantopoulos, A P; Døhn, U Møller

    2017-01-01

    Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used...

  20. Breast ultrasound scans – surgeons’ expectations

    Directory of Open Access Journals (Sweden)

    Piotr Bednarski

    2015-06-01

    Full Text Available Recent years have witnessed a dynamic development of mammary gland imaging techniques, particularly ultrasonography and magnetic resonance imaging. A challenge related to these studies is the increase in the precision of the anatomical assessment of breast, particularly for early detection of subclinical lesions, performance of ultrasound-guided biopsy procedures, and accurate preoperative location of pathological lesions so as to optimize the surgical treatment. Ultrasound imaging is a primary and baseline diagnostic procedure the patient with suspected pathological lesions within breast is referred to by the surgeon. Lesions visualized in ultrasound scans are classifi ed according to the BI-RADS US assessment categories. The successive categories (2 through 6 encompass individual pathological lesions, estimating the risk of malignancy and provide guidelines for further diagnostic and therapeutic management. This article described the important aspects of ultrasonographic imaging of focal lesions within the breasts as signifi cant from the standpoint of surgical treatment of patients falling within BI-RADS US categories 3, 4, 5, and 6. Attention is drawn to the importance of ultrasound scans in the assessment of axillary fossa lymph nodes before the decision regarding the surgical treatment.

  1. TEACHING PHYSICS: An experiment to demonstrate the principles and processes involved in medical Doppler ultrasound

    Science.gov (United States)

    Andrews, D. G. H.

    2000-09-01

    Doppler ultrasound is widely used in medicine for measuring blood velocity. This paper describes an experiment illustrating the principles of medical Doppler ultrasound. It is designed with A-level/undergraduate physics students in mind. Ultrasound is transmitted in air and reflected from a moving target. The return signal is processed using a series of modules, so that students can discover for themselves how each stage in the instrument works. They can also obtain a quantitative value of the speed of the target.

  2. TU-A-9A-02: Analysis of Variations in Clinical Doppler Ultrasound Peak Velocity Measurements

    International Nuclear Information System (INIS)

    Zhang, Y; Stekel, S; Tradup, D; Hangiandreou, N

    2014-01-01

    Purpose: Doppler ultrasound (US) peak velocity (Vmax) measurements show considerable variations due to intrinsic spectral broadening with different scanning techniques, machines and manufacturers. We developed a semi-automated Vmax estimation method and used this method to investigate the performance of a US system for clinical Doppler Vmax measurement. Methods: Semi-automated Vmax is defined as the velocity at which the computed mean spectral profile falls to within 1 background standard deviation of the background mean. GE LOGIQ E9 system with 9L and ML6-15 probes were studied with steady flow (5.3 – 12.5 ml/s) in a Gammex OPTIMIZER 1425A phantom. All Doppler spectra were acquired by 1 operator at the distal end of 5 mm angular tube using a modified clinical carotid artery protocol. Repeatability and variation of Vmax to scanning parameters and probes were analyzed and reported as percentage, i.e. (max-min)/mean. Results: Vmax estimation had good repeatability (3.1% over 6 days for 9L, and 3.6% for ML6-15). For 9L probe, varying gain, compression, scale, SV depth and length, and frequency had minimal impact on Vmax (all variations less than 4.0%). Beam steering had slightly higher influence (largest variations across flow rates were 4.9% for 9L and 6.9% for ML6-15). For both probes, Doppler angle had the greatest effect on Vmax. Percentage increase of Vmax was largely independent of actual flow rates. For Doppler angle varied from 30 to 60°, Vmax increased 24% for 9L, and 20% for ML6-15. Vmax measured by ML6-15 were lower than that by 9L at each Doppler angle with differences less than 5%. Conclusion: The proposed Vmax estimation method is shown to be a useful tool to evaluate clinical Doppler US system performance. For the tested system and probes, Doppler angle had largest impact in measured Vmax

  3. Comparison of blood flow velocity through the internal carotid artery based on Doppler ultrasound and numerical simulation

    International Nuclear Information System (INIS)

    Hassani-Ardekani, Hajar; Ghalichi, Farzan; Niroomand-Oscuii, Hanieh; Farhoudi, Mehdi; Tarzmani, Mohammad K.

    2012-01-01

    Doppler ultrasound is a usual non-invasive method to estimate the stenosis percentage in large arteries such as carotid by measuring maximum velocity of blood flow. Based on clinical investigations, because of vessel wall motions, Doppler positioning and angle correction, some errors can arise in Doppler results which lead to incorrect diagnosis. The aim of this study was to compare the results of Doppler test and the numerical simulation of blood flow in the same case. For this evaluation, two patients including an 87-year-old man and a 72-year-old woman suffering from stenosis in the internal carotid artery were selected. First, clinical information of each patient such as CT-Angio scan images and Doppler ultrasound results on different locations of the stenosed artery were obtained. Then, the geometries were reconstructed and numerical simulations were carried out using ANSYS software. Results showed that the velocity profile of Doppler test and numerical simulation were in good agreement at the regions of pre-and post-stenosis. However, the value of maximum velocity at the stenotic region had significant differences.

  4. The value of palpation, varicoscreen contact thermography and colour Doppler ultrasound in the diagnosis of varicocele

    NARCIS (Netherlands)

    Trum, J. W.; Gubler, F. M.; Laan, R.; van der Veen, F.

    1996-01-01

    Three non-invasive methods for the detection of a varicocele were evaluated in 63 men presenting with infertility. Physical examination, varicoscreen contact thermography and colour Doppler ultrasound were compared with spermatic venography as reference strategy. Physical examination had a

  5. [Prognostic Doppler ultrasound examination of fetal arteries blood flow].

    Science.gov (United States)

    Sieroszewski, Piotr; Sabatowska, Małgorzata; Karowicz-Bilińska, Agata; Suzin, Jacek

    2002-08-01

    Early detection of fetal risk is one of the main issues in today obstetrics. Ultrasound diagnostics plays a significant role, as the introduction of Doppler imaging method in the evaluation of blood flow has enabled non-invasive assessment of uteroplacental circulation. Therefore, we have analysed foetal three arteries: umbilical artery, middle cerebral artery and renal artery after determining the normal range for the analysed parameters. 1. Comparison of the obtained blood flow indices (S/D, RI, PI) in the umbilical artery, middle cerebral artery and renal artery of foetuses from normal and complicated full-term pregnancies. 2. Determination of indices: umbilical-cerebral and renal-cerebral in normal and pathological pregnancy. 3. Evaluation of feasibility of the analysed flow parameters for the detection of intrauterine foetal hypoxia. We have examined 151 women, who were divided into control group--101 pregnant women with normal pregnancy and study group--50 pregnant women with complicated pregnancy. All pregnant women underwent ultrasound examination using the Hitachi EUB 515 C (Japan) scanner with 3.5 MHz convex probe, connected to the colour pulsed Doppler. The study consisted of the biometric measurements and evaluation of the spectrum of blood flow in the umbilical artery, middle cerebral artery and renal artery. We have determined following indices: a) systolic-diastolic ratio S/D, resistance index RI, pulsatility index PI, b) umbilical-cerebral ratio P/M. (PI ua/PI mca), renal--cerebral ratio N/M (PI ra/PI mca). Statistically significant difference was found between the study and control groups for all the flow indices assessed (S/D, RI, PI) for the middle cerebral artery, for the indices P/M and N/M. (p < 0.001) and pulsatility index in the renal artery (p < 0.01). Similar, although slightly smaller difference (p < 0.05) was seen for the values of flow parameters in the umbilical artery. 1) Evaluation of blood flow in the middle cerebral artery, and in

  6. Budd-Chiari syndrome: diagnosis with ultrasound and nuclear medicine calcium colloid liver scan following non-diagnostic contrasted CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Mulholland, J.P.; Fong, S.M.; Kafaghi, F.A.; Fong, W. [Royal Brisbane Hospital, Herston, QLD (Australia)

    1997-02-01

    Budd-Chiari syndrome is a rare condition characterized by thrombosis within the hepatic veins and inferior vena cava. A case of Budd-Chiari syndrome is presented in a patient who experienced acutely 3 days following laparoscopic cholecystectomy for a calculous cholecystitis. A discussion of pathology and findings on calcium colloid scintigram, CT scan and Doppler ultrasound is provided. 5 refs., 4 figs.

  7. The diagnostic value of transvaginal color Doppler ultrasound in obstetrical and gynecological emergency

    International Nuclear Information System (INIS)

    Mai Caitian; Su Xiaowei; Lin Meifang

    2007-01-01

    Objective: To investigate the diagnostic value of transvaginal color Doppler ultrasound in obstetrical and gynecological emergency. Methods: Cases of all kinds of obstetrical and gynecological emergency diseases diagnosed and managed in out hospital from 2003 to 2005 were included. Transvaginal color Doppler sonogr aphic findings, clinical treatments, pathologic results were followed up and analyzed. Results: Accurate diagnosis was made in 194 of 201 cases (96.5%), False diagnostic rate is 3.5%. Conclusion: Transvaginal color Doppler ultrasound may give precise diagnosis for the obstetrical and gynecological emergency diseases. It is the preferred auxiliary method for the diagnosis of gynecological emergency diseases. (authors)

  8. Endoscopic ultrasound duplex scanning for measurement of portal venous flow. Validation against transit time ultrasound flowmetry in pigs

    DEFF Research Database (Denmark)

    Hansen, Erik Feldager; Strandberg, C; Bendtsen, F

    1999-01-01

    with that of transit time ultrasound (TTU) in healthy pigs. The ability of EUS to detect changes in the portal venous flow after pharmacologic intervention was also investigated. METHODS: Six anaesthetized pigs were studied. Portal venous flow was measured simultaneously by EUS duplex scanning, using a Pentax FG-32UA...... correlated significantly (R = 0.88, P measurements. CONCLUSIONS: EUS measures portal venous flow with an acceptable correlation and agreement with TTU in anaesthetized pigs. The method is capable of monitoring the effects......BACKGROUND: Endoscopic ultrasound (EUS) is a new technique that makes it possible to measure portal venous flow when transabdominal ultrasound fails. As the technique has not been evaluated previously, we compared simultaneous measurements of portal venous flow using EUS Doppler...

  9. Contrast angiosonography: a technology to improve Doppler ultrasound examinations of the prostate

    NARCIS (Netherlands)

    Aarnink, R. G.; Beerlage, H. P.; de la Rosette, J. J.; Debruyne, F. M.; Wijkstra, H.

    1999-01-01

    OBJECTIVES: A feasibility study to evaluate whether analysis techniques adapted from X-ray angiography can be used to analyze the transient enhancement of prostate blood flow patterns in color Doppler maps as obtained after administering ultrasound contrast agents. METHODS: Injections of ultrasound

  10. Doppler ultrasound compared with strain gauge for measurement of systolic ankle blood pressure.

    Science.gov (United States)

    Joensen, J B; Juul, S; Abrahamsen, J; Henneberg, E W; Lindholt, Jes S

    2008-01-01

    This study assesses measurement variation in the measurement of ankle systolic blood pressure (ABP) when measured with Doppler ultrasound and with the strain gauge method. Ninety-seven patients were included. ABP was measured with Doppler ultrasound and with the strain gauge method. The methods were compared graphically by scatterplots and analyzed by paired t test, analysis of variance, and Pitman's paired variance ratio test. ABP was measured by strain gauge in all extremities, whereas no Doppler signal was obtainable in 7 limbs (4%). There was no systematic difference in measurements between the means of the two measurements. However, a substantial difference of more than 25 mm Hg was found in 15% of limbs and more than 20 mm Hg in 20%. In the majority of patients, measurements of ABP by Doppler ultrasound and the strain gauge method give similar results, but for a minority the discrepancy is substantial.

  11. Experience and use of ultrasound scan for fetal evaluation among ...

    African Journals Online (AJOL)

    Aim: To assess the experience and the use of ultrasound scan for fetal evaluation among obstetricians. Material and Methods: Fifty three Obstetricians who attended an international conference on Fetal Medicine and Obstetric Ultrasound scan held in May 2014 at the University of Benin Teaching Hospital were recruited for ...

  12. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  13. Use of ultrasound, color Doppler imaging and radiography to monitor periapical healing after endodontic surgery.

    Science.gov (United States)

    Tikku, Aseem P; Kumar, Sunil; Loomba, Kapil; Chandra, Anil; Verma, Promila; Aggarwal, Renu

    2010-09-01

    This study evaluated the effectiveness of ultrasound, color Doppler imaging and conventional radiography in monitoring the post-surgical healing of periapical lesions of endodontic origin. Fifteen patients who underwent periapical surgery for endodontic pathology were randomly selected. In all patients, periapical lesions were evaluated preoperatively using ultrasound, color Doppler imaging and conventional radiography, to analyze characteristics such as size, shape and dimensions. On radiographic evaluation, dimensions were measured in the superoinferior and mesiodistal direction using image-analysis software. Ultrasound evaluation was used to measure the changes in shape and dimensions on the anteroposterior, superoinferior, and mesiodistal planes. Color Doppler imaging was used to detect the blood-flow velocity. Postoperative healing was monitored in all patients at 1 week and 6 months by using ultrasound and color Doppler imaging, together with conventional radiography. The findings were then analyzed to evaluate the effectiveness of the 3 imaging techniques. At 6 months, ultrasound and color Doppler imaging were significantly better than conventional radiography in detecting changes in the healing of hard tissue at the surgical site (P radiography in monitoring the post-surgical healing of periapical lesions of endodontic origin.

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  15. Transrectal ultrasound color Doppler in the evaluation of recurrence of anal canal cancer

    International Nuclear Information System (INIS)

    Drudi, Francesco M.; Giovagnorio, Francesco; Raffetto, Nicola; Ricci, Paolo; Cascone, Fiammetta; Santarelli, Mario; Trippa, Francesca; Passariello, Roberto

    2003-01-01

    Objective: aim was to obtain elements for a differential diagnosis between post-radiation fibrosis and residual tumor or local relapse in anal canal cancer through detection of presence/absence of intralesional blood flow. Transrectal ultrasound and color Doppler were compared. Methods: 43 patients underwent transrectal ultrasound sonography and color Doppler before and after therapy to assess intralesional blood flow and flow pattern (spotty and linear signals). All diagnostic imaging results were compared to histological analysis. Specificity was submitted to statistical analysis using McNemar test. Results: before therapy 34 lesions (79%) showed color signal; no signal in 9 (21%), which were excluded from our analysis. Eighteen of the 34 patients considered, presented complete response to therapy, 14 partial response and two no response. After therapy, signal disappeared in 17 patients (94%); one false-positive (6%) presented spotty signals; 16 of 34 patients presented changed color signal. Color Doppler showed higher specificity than grey scale transrectal ultrasound in the differentiation of fibrosis from tumor. Response was confirmed by histological examination, considered gold standard. McNemar test demonstrated the significance of color Doppler (P<0.0001). Conclusion: color Doppler considerably increases transrectal ultrasound specificity in differentiating tumor relapse from fibrosis in anal canal cancer

  16. The value of mammography, color doppler ultrasound and biopsy in diagnosis of early breast cancer

    International Nuclear Information System (INIS)

    Guo Qinglu; Ye Zhiqiu; Liu Qingyu

    2001-01-01

    Objective: To study the diagnostic value of mammography, color Doppler ultrasound and biopsy in early breast cancer and to evaluate its diagnostic accuracy. Methods: 55 patients with breast cancer and 25 patients with benign breast masses, proved pathologically, were checked by mammography, color Doppler ultrasound and biopsy. Results: Mammography demonstrated breast cancer in 45 cases, the sensitivity and specificity were 82.0% and 88.0%, respectively, with the accuracy of 83.8%; Color Doppler ultrasound revealed breast cancer in 43 cases, the sensitivity, specificity and accuracy were 78.2%, 84.0% and 80.0%; Biopsy demonstrated breast cancer in 53 cases, the sensitivity, specificity and accuracy were 96.4%, 92.0% and 95.0%. When ultrasound, mammography and biopsy were combined together, the sensitivity, specificity and accuracy were 98.2%, 96.0% and 97.5%. Conclusion: Mammography, color Doppler ultrasound combined with biopsy can increase the diagnostic sensitivity and accuracy of early breast cancers

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  18. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  19. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  20. Spatial Angular Compounding Technique for H-Scan Ultrasound Imaging.

    Science.gov (United States)

    Khairalseed, Mawia; Xiong, Fangyuan; Kim, Jung-Whan; Mattrey, Robert F; Parker, Kevin J; Hoyt, Kenneth

    2018-01-01

    H-Scan is a new ultrasound imaging technique that relies on matching a model of pulse-echo formation to the mathematics of a class of Gaussian-weighted Hermite polynomials. This technique may be beneficial in the measurement of relative scatterer sizes and in cancer therapy, particularly for early response to drug treatment. Because current H-scan techniques use focused ultrasound data acquisitions, spatial resolution degrades away from the focal region and inherently affects relative scatterer size estimation. Although the resolution of ultrasound plane wave imaging can be inferior to that of traditional focused ultrasound approaches, the former exhibits a homogeneous spatial resolution throughout the image plane. The purpose of this study was to implement H-scan using plane wave imaging and investigate the impact of spatial angular compounding on H-scan image quality. Parallel convolution filters using two different Gaussian-weighted Hermite polynomials that describe ultrasound scattering events are applied to the radiofrequency data. The H-scan processing is done on each radiofrequency image plane before averaging to get the angular compounded image. The relative strength from each convolution is color-coded to represent relative scatterer size. Given results from a series of phantom materials, H-scan imaging with spatial angular compounding more accurately reflects the true scatterer size caused by reductions in the system point spread function and improved signal-to-noise ratio. Preliminary in vivo H-scan imaging of tumor-bearing animals suggests this modality may be useful for monitoring early response to chemotherapeutic treatment. Overall, H-scan imaging using ultrasound plane waves and spatial angular compounding is a promising approach for visualizing the relative size and distribution of acoustic scattering sources. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  1. Transcranial Doppler ultrasound during galvanic labyrinth polarization depicts central vestibular processing, demonstrating bilateral vestibular projection.

    Science.gov (United States)

    Schlosser, Hans-Georg; Guldin, Wolfgang; Fritzsche, Danny; Clarke, Andrew H

    2008-07-01

    The combination of galvanic labyrinth polarization and transcranial Doppler ultrasound was employed to depict the neurovascular coupling in the cerebral vestibular areas. For galvanic stimulation, surface electrodes were attached to the right and left mastoid and two further electrodes were fixed near to each shoulder blade. Thus, each pair of electrodes (mastoid to shoulder) facilitated unilateral stimulation of the ipsilateral vestibular labyrinth. Blood flow in the middle cerebral artery and the internal carotid artery in both hemispheres was measured by means of Doppler ultrasound. The transcranial Doppler ultrasound system was head-fixed and allowed continuous monitoring of the blood flow throughout the trials. Using a series of different stimulation modes (bilateral, unilateral left, unilateral right and sham), the changes in mean blood flow velocity were evaluated by comparing baseline blood flow under resting conditions to blood flow during stimulation. A total of 18 trials were performed with each of seven volunteer subjects. Galvanic labyrinth polarization elicited a clear sensation of pendular body movement in all subjects. Significant blood flow increase (P < 0.05) in both hemispheres was observed during bilateral stimulation. Of more interest is that unilateral stimulation also elicited a significant increase in flow in both the ipsilateral and the contralateral hemispheres, demonstrating the existence of bilateral projections from each vestibular labyrinth. The combination of galvanic labyrinth polarization with transcranial Doppler ultrasound blood flow measurement provides a novel approach to the functional assessment of the vestibular system (deep cerebral structures and cortical areas). This novel technique provides a useful tool for clinical examinations.

  2. CALF BLOOD-FLOW AND POSTURE - DOPPLER ULTRASOUND CALIBRATED BY PLETHYSMOGRAPHY

    NARCIS (Netherlands)

    VANLEEUWEN, BE; LUBBERS, J; BARENDSEN, GJ; DEPATER, L

    A procedure was developed that enables measurement of rapid variations in calf blood flow during voluntary rhythmic contraction of the calf muscles in supine, sitting, and standing positions. During the exercise, maximum blood velocity is measured by Doppler ultrasound equipment in the popliteal

  3. Spectral Doppler ultrasound of peripheral arteries: a pictorial review.

    Science.gov (United States)

    Nuffer, Zachary; Rupasov, Andrey; Bekal, Neel; Murtha, Jacqueline; Bhatt, Shweta

    This article reviews the pathophysiology and sonographic findings of peripheral arterial lesions, with emphasis on the spectral Doppler waveforms encountered in each. It discusses the characteristic features of the Doppler spectra in obstructive conditions, including thromboembolism, atherosclerotic disease, bypass graft occlusion, dissection, trauma, and compartment syndrome, as well as non-obstructive conditions, including hyperemia, pseudoaneurysm, and arteriovenous fistula. Familiarity with the commonly-encountered spectral waveforms in the setting of these lesions is necessary for timely and accurate diagnosis and treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Remote Electromagnetic Vibration of Steerable Needles for Imaging in Power Doppler Ultrasound

    Science.gov (United States)

    Cabreros, Sarah S.; Jimenez, Nina M.; Greer, Joseph D.; Adebar, Troy K.; Okamura, Allison M.

    2015-01-01

    Robotic needle steering systems for minimally invasive medical procedures require complementary medical imaging systems to track the needles in real time. Ultrasound is a promising imaging modality because it offers relatively low-cost, real-time imaging of the needle. Previous methods applied vibration to the base of the needle using a voice coil actuator, in order to make the needle visible in power Doppler ultrasound. We propose a new method for needle tip vibration, using electromagnetic actuation of small permanent magnets placed inside the needle to improve needle tip visibility in power Doppler imaging. Robotic needle insertion experiments using artificial tissue and ex vivo porcine liver showed that the electromagnetic tip vibration method can generate a stronger Doppler response compared to the previous base vibration method, resulting in better imaging at greater needle depth in tissue. It also eliminates previous issues with vibration damping along the shaft of the needle. PMID:26413379

  5. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    excluded from the study. Color Doppler was performed in all cases, followed by laparoscopy. Further, findings on laparoscopy were compared with those of CDUS. A 95% confidence interval for the sensitivity of CDUS was estimated considering a positive result on CDUS as the binomial variable. Results. Out of 25 patients, ...

  6. [Application of high frequency color Doppler ultrasound in anterolateral thigh flap surgery].

    Science.gov (United States)

    Xiao, Haitao; Shi, Yingyu; Wang, Huaisheng; Liu, Yong; Zhang, Yange; Cen, Ying

    2013-02-01

    To investigate the effectiveness of high frequency color Doppler ultrasound for detecting perforators in the anterolateral thigh (ALT) flap surgery. Between February 2011 and July 2012, 8 patients underwent high frequency color Doppler ultrasound to detect the perforator anatomy before ALT flap surgery. There were 5 males and 3 females, aged 21-46 years (mean, 34 years). Defects were caused by excision of squamous cell carcinoma in 2 cases, by scalp avulsion in 2 cases, by soft tissue necrosis after neck trauma in 1 case, by excision of groin fibrosarcoma in 1 case, by excision of groin melanoma in 1 case, and by malformation of the face in 1 case. The defect size varied from 12 cm x 7 cm to 22 cm x 18 cm. The perforator with wider caliber, faster flow speed, and shorter intramuscular trajectory was selected, and the flap was designed according to the observed results, which size varied from 14 cm x 9 cm to 25 cm x 20 cm. The donnor sites were repaired by free skin graft. Totally, 19 perforators in the flap area were detected by high frequency color Doppler ultrasound, and 18 were identified during operation, with an accuracy rate of 94.7%. The point going out muscle, the travel and direction of perforators observed during operation were basically in accordance with those detected by high frequency color Doppler ultrasound. The other flaps survived, and obtained healing by first intention except 1 flap which had partial fat necrosis with healing by second intention. The skin graft at donor site survived. All patients followed up 4-16 months (mean, 8 months). The flaps had good color and texture. High frequency color Doppler ultrasound is a valuable imaging modality for the preoperative assessment of the vascular supply for ALT flap.

  7. Detection of a lumbar foraminal venous varix by Color Doppler Ultrasound.

    Science.gov (United States)

    Darrieutort-Laffite, Christelle; Desal, Hubert; Berthelot, Jean-Marie; Le Goff, Benoît

    2016-07-01

    Ultrasonography is currently widely used in the rheumatology practice. Although mainly performed to study peripheral joint, several articles have underlined its interest to study spinal anatomy. However, its ability to provide diagnostic features is unknown. We studied the case of a 25-year-old woman having low back pain. Three different imaging modalities (Computed Tomography [CT], Magnetic Resonance Imaging [MRI] and Ultrasound) were used to explore it. CT and MRI showed a foraminal dilation of the lombo-ovarian vein at the L3-L4 level with a scalloping of the lateral edge of L3. We were able to detect it with Color Doppler Ultrasound and a malformation of the inferior vena cava was also found. We showed for the first time that Color Doppler Ultrasound can detect venous malformation of the spine. This imaging modality could help us in the diagnosis of atypical lesions of the spine to confirm their vascular origin. Copyright © 2016. Published by Elsevier SAS.

  8. Practical recommendations for performing ultrasound scanning in the urological and andrological fields

    Directory of Open Access Journals (Sweden)

    Pasquale Martino

    2014-03-01

    Full Text Available Aim: US scanning has been defined as the urologist’s stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Methods: Members of the Imaging Working Group of the Italian Society of Urology (SIU in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Results: Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Conclusions: Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter

  9. Ultrasound assessed thickness of burn scars in association with laser Doppler imaging determined depth of burns in paediatric patients.

    Science.gov (United States)

    Wang, Xue-Qing; Mill, Julie; Kravchuk, Olena; Kimble, Roy M

    2010-12-01

    This study describes the ultrasound assessment of burn scars in paediatric patients and the association of these scar thickness with laser Doppler imaging (LDI) determined burn depth. A total of 60 ultrasound scar assessments were conducted on 33 scars from 21 paediatric burn patients at 3, 6 and 9 months after-burn. The mean of peak scar thickness was 0.39±0.032 cm, with the thickest at 6 months (0.40±0.036 cm). There were 17 scald burn scars (0.34±0.045 cm), 4 contact burn scars (0.61±0.092 cm), and 10 flame burn scars (0.42±0.058 cm). Each group of scars followed normal distributions. Twenty-three scars had original burns successfully scanned by LDI and various depths of burns were presented by different colours according to blood perfusion units (PU), with dark blue burns, with the thinnest scars for green coloured burns and the thickest for dark blue coloured burns. Within light blue burns, grafted burns healed with significantly thinner scars than non-grafted burns. This study indicates that LDI can be used for predicting the risk of hypertrophic scarring and for guiding burn care. To our knowledge, this is the first study to correlate the thickness of burns scars by ultrasound scan with burn depth determined by LDI. Copyright © 2010 Elsevier Ltd and ISBI. All rights reserved.

  10. Preoperative imaging for DIEA perforator flaps: a comparative study of computed tomographic angiography and Doppler ultrasound.

    Science.gov (United States)

    Rozen, Warren M; Phillips, Timothy J; Ashton, Mark W; Stella, Damien L; Gibson, Robert N; Taylor, G Ian

    2008-01-01

    Abdominal donor-site flaps, including the transverse rectus abdominis musculocutaneous (TRAM) and deep inferior epigastric artery (DIEA) perforator flaps, are standard in autologous breast reconstruction. With significant variation in the vascular anatomy of the abdominal wall, preoperative imaging is essential for preoperative planning and reducing intraoperative error. Doppler and color duplex sonography have been used with varying results, and the quest continues for optimal preoperative assessment. Computed tomographic angiography has recently been proposed as a noninvasive modality for this purpose. This is the first study to formally compare preoperative Doppler ultrasound with computed tomographic angiography for imaging the DIEA. Eight consecutive patients undergoing DIEA perforator flap surgery for breast reconstruction underwent both computed tomographic angiography and Doppler ultrasound preoperatively. All investigations and procedures were performed at the same institution with the same primary and assisting surgeons and the same radiology team. Computed tomographic angiography was superior to Doppler ultrasound at identifying the course of the DIEA and its branching pattern, and in visualizing its perforators. Preoperative computed tomographic angiography was highly specific (100 percent) and more sensitive in mapping and visualizing perforators (p = 0.0078). It was also proficient at identifying the superficial epigastric arterial system and for effectively displaying the results intraoperatively. It was substantially quicker and removed the interobserver error associated with Doppler ultrasonography. The study was ceased after eight patients because of the overwhelming benefit of computed tomographic angiography over Doppler ultrasonography. Computed tomographic angiography is a valuable imaging modality for the preoperative assessment of the donor-site vascular supply for TRAM and DIEA perforator flaps.

  11. Color doppler ultrasound of hepatocellular carcinoma : evaluation of recurrence after transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Kim, Jong Min; Huh, Jin Do; Cho, Young Duk; Lee, Sang Uk

    1999-01-01

    To evaluate the efficacy of color and pulsed Doppler ultrasound (US) for the detection of arterial revascularization of hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE). One hundred and four histologically proven HCCs (0.7-12.5 cm, mean 4.14 cm) of 87 consecutive patients who had undergone TACE using a Lipiodol-chemoagent suspension were examined using color Doppler equipment. The criteria for diagnosing arterial revascularization of HCC were detection of inward blood vessels within HCC and demonstration by spectral Doppler US of pulsatile arterial flow within the vessel. Color Doppler US was prospectively performed using a multi-Hertz probe (2.5-5 Hz), and was followed by digital subtraction angiography (DSA). In 37 of 104 HCCs in 87 patients treated with TACE, color and spectral Doppler US demonstrated intratumoral arterial flows, with peak systolic velocity of 4.2-220 (mean, 59) cm/sec. DSA revealed neovascularity or tumor stains in 38 HCCs (3.4-12.5 cm, mean 5.9 cm in size) including 37 which on Doppler US showed arterial flow. The remaining 66 of 104 HCCs (0.7-6.3 cm, mean 3.2 cm) did not stain during DSA. Doppler US showed a false negative result in only one HCC (4.6 cm, located at segment VIII of the Couinaud classification), which stained faintly during DSA. The sensitivity, specificity, and accuracy of color and spectral Doppler US used for the detection of recurrent HCC were 97.4%, 100%, and 99%, respectively. Color and spectral Doppler US is an effective method for the evaluation of arterial revascularization of HCC after TACE

  12. Doppler ultrasound study of penis in men with systemic sclerosis: a correlation with Doppler indices of renal and digital arteries.

    Science.gov (United States)

    Rosato, E; Barbano, B; Gigante, A; Cianci, R; Molinaro, I; Quarta, S; Digiulio, M A; Messineo, D; Pisarri, S; Salsano, F

    2013-01-01

    Erectile dysfunction (ED) prevalence in male systemic sclerosis (SSc) is high and its pathogenesis is unclear. The aim of the study is to assess correlation between Doppler ultrasound indices of penis and kidneys or digital arteries in male systemic sclerosis. Fourteen men with systemic sclerosis were enrolled in this study. Erectile function was investigated by the International Index of Erectile Function-5. Peak systolic velocity, end diastolic velocity, resistive index, pulsative index, and systolic/diastolic ratio were measured on the cavernous arteries at the peno-scrotal junction in the flaccid state, on the interlobar artery of both kidneys and all ten proper palmar digital arteries. Ten (71 percent) patients have an International Index of Erectile Function-5 less than 21. Reduction of penis peak systolic velocity was observed in all SSc subjects. Doppler indices of cavernous arteries correlate with the International Index of Erectile Function-5. The renal and digital arteries resistive index demonstrated a good correlation (p less than 0.0001) with International Index of Erectile Function-5. A positive correlation exists between penis and kidney arteries Doppler indices: end diastolic velocity (p less than 0.05, r=0.54), resistive index (p less than 0.0001, r=0.90), systolic/diastolic ratio (p less than 0.01, r=0.69). A positive correlation was observed between penis and digital arteries Doppler indices: peak systolic velocity (p less than 0.01, r=0.68), end diastolic velocity (p less than 0.01, r=0.75), resistive index (p less than 0.001, r=0.79), systolic/diastolic ratio (p less than 0.05, r=0.59). A correlation exists between arterial impairment of penis and renal or digital arteries.

  13. Colour doppler ultrasound assessment of the normal neonatal hip

    International Nuclear Information System (INIS)

    Ortiz-Neira, C.L.; Laffan, E.; Daneman, A.; Fong, K.; Roposch, A.

    2009-01-01

    To determine the morphology and hemodynamic characteristics of the arterial vessels of the proximal femur according to specific anatomic regions in asymptomatic neonates in 2 pediatric-based health care institutions. Forty-three neonates (29 female, 14 male; age range, 2 d-3 mo; median age, 3 d) were enrolled in the study. Thirty-two (37%) of 86 hips were classified as Graf type IIA joints (mean alpha angle, 56.0 o ± 2.7 o ), and 54 (63%) were classified as type I joints (mean alpha angle, 65.0 o ± 4.6 o ). Colour and spectral Doppler imaging identified vessels running along the acetabular labrum, epiphyseal vessels, and femoral neck. We showed 4 different patterns of vascularity of the hips: radial, parallel, mixed radial-parallel, and indeterminate, however, they were not related to the hip maturity (P = .3, coronal plane; P = .62, transverse plane) or to the amount of colour pixels identified in each region (P = .35). The mean number of pixels in the ligamentum teres region was significantly higher than that in other regions of interest (P =.03). Except for the acetabular labrum arteries, Doppler spectrum waveforms of proximal femur arteries presented with low resistivity. There was a tendency towards females' acetabular arteries presenting with lower peak systolic velocities than males' acetabular arteries (P =.06). Colour Doppler spectrum waveforms and intensity of vascularity in normal neonatal hips differ according to the anatomic region under evaluation. This observation deserves further investigation on its role on the physiopathogenesis of neonatal hip disorders. (author)

  14. Sport and exercise medicine consultants are reliable in assessing tendon neovascularity using ultrasound Doppler.

    Science.gov (United States)

    Watson, James; Barker-Davies, Robert M; Bennett, Alexander N; Fong, Daniel T P; Wheeler, Patrick C; Lewis, Mark; Ranson, Craig

    2018-01-01

    Several lower limb tendinopathy treatment modalities involve identification of pathological paratendinous or intratendinous neovascularisation to target proposed co-location of painful neoneuralisation. The ability to reliably locate and assess the degree of neovascularity is therefore clinically important. The Modified Ohberg Score (MOS) is frequently used to determine degree of neovascularity, but reliability has yet to be established among Sport and Exercise Medicine (SEM) consultants. This study aims to determine inter-rater and intra-rater reliability of an SEM consultant cohort when assessing neovascularity using the 5-point MOS. Eleven participants (7 male and 4 female) provided 16 symptomatic Achilles and patella tendons. These were sequentially examined using power Doppler (PD) enabled ultrasound (US) imaging by 6 SEM consultants who rated neovascular changes seen using the MOS. Representative digital scan images were saved for rescoring 3 weeks later. Inter-rater and intra-rater reliability of the MOS was examined using intraclass correlation coefficient (ICC) and Kappa Agreement scores. Neovascular changes were reported in 65.6% of 96 scans undertaken. ICC for inter-rater reliability was 0.86 and Fleiss Kappa 0.52. ICC for intra-rater reliability was 0.95 and Weighted Kappa 0.91. Neovascular changes were present in two-thirds of symptomatic tendons. Excellent SEM consultant inter-rater and intra-rater reliability was demonstrated. These findings support the use of PD-enabled US to assess neovascularity by appropriately experienced SEM consultants. Furthermore, future interventional research using a similarly experienced SEM consultant cohort can be undertaken with assurance that assessment of neovascularity will be reliable.

  15. Local Lorentz force and ultrasound Doppler velocimetry in a vertical convection liquid metal flow

    OpenAIRE

    Zürner, Till; Vogt, Tobias; Resagk, Christian; Eckert, Sven; Schumacher, Jörg

    2017-01-01

    We report velocity measurements in a vertical turbulent convection flow cell that is filled with the eutectic liquid metal alloy gallium-indium-tin by the use of local Lorentz force velocimetry (LLFV) and ultrasound Doppler velocimetry (UDV). We demonstrate the applicability of LLFV for a thermal convection flow and reproduce a linear dependence of the measured force in the range of micronewtons on the local flow velocity magnitude. Furthermore, the presented experiment is used to explore sca...

  16. Magnetic resonance imaging in the evaluation of placental adhesive disorders: correlation with color Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Masselli, Gabriele; Casciani, Emanuele; Polettini, Elisabetta; Gualdi, Gianfranco [Umberto I Hospital-La Sapienza University, Department of Radiology DEA, Rome (Italy); Brunelli, Roberto; Piccioni, Maria G.; Anceschi, Maurizio [Umberto I Hospital-La Sapienza University, Department of Gynecology and Obstetrics, Rome (Italy)

    2008-06-15

    The purpose of this study was to compare the value of pelvic ultrasound with color Doppler and magnetic resonance imaging (MRI) in: (1) the diagnosis of placental adhesive disorders (PADs), (2) the definition of the degree of placenta invasiveness, (3) determining the topographic correlation between the diagnostic images and the surgical results. Fifty patients in the third trimester of pregnancy with a diagnosis of placenta previa and at least one previous caesarean section underwent color Doppler ultrasound (US) and MRI. The sonographic and MRI diagnoses were compared with the final pathologic or operative findings. Outcomes at delivery were as follows: normal placenta (n = 38) and PAD (n = 12). MR and US Doppler showed no statistically difference in identiyfing patients with PAD (P = 0.74), while MRI was statistically better than US Doppler in evaluating the depth of placenta infiltration (P < 0.001). MRI accurately characterized the topography of invasion in 12/12 (100%) of the cases, while US accurately characterized the topography of invasion in 9/12 (75%) of the cases. In conclusion, we confirmed that pelvic US is highly reliable to diagnose or exclude the presence of PAD and found MRI to be an excellent tool for the staging and topographic evaluation of PAD. (orig.)

  17. Ultrasound scanning in planning radiotherapy in cervix uteri cancer stump

    International Nuclear Information System (INIS)

    Nazarova, I.S.; Demidova, L.V.

    1989-01-01

    Application of ultrasound scanning for topometric preparation of 63 patients with cervix uteri cancer stump enabled to visualize clearly cervix uteri stump in a small pelvis and determine exactly its sizes and cupola thickness in particular. This enabled to improve the technique of combined radiotherapy and achieve five-year survival rate equal to 76.9%

  18. pattern of ultrasound scanning in owerri south eastern nigeria

    African Journals Online (AJOL)

    Uche

    Ultrasound waves are sound waves travelling beyond 20,000 cycles per second. At this frequency they are ... which now converts the returning waves into electrical energy which is displayed by a cathode ray tube as ... Moreover. Magnetic Resonance Imaging(MRI) and CAT scans are bulky and unaffordable to most people.

  19. Doppler ultrasound and tibial tuberosity maturation status predicts pain in adolescent male athletes with Osgood-Schlatter's disease: a case series with comparison group and clinical interpretation

    Science.gov (United States)

    Sailly, Matthieu; Whiteley, Rod; Johnson, Amanda

    2013-01-01

    Background The pathogenesis of the Osgood-Schlatter's disease (OSD) is still debated. The fragmentation of the ossification centre has been questioned as a definitive sign of OSD and has been seen as a normal development of the anterior tibial tubercle (ATT). Objectives It is unknown if such changes are present in the presumed pathological tendon insertion seen in OSD, nor the relation of Doppler-positive changes to pain on clinical examination. Methods A prospective analysis was carried out on 20 consecutive symptomatic male athletes (13.9 years±1.3) and a comparison group of asymptomatic subjects. All underwent a comparative clinical assessment and ultrasound with colour Doppler scan on both knees. Subjective pain was recorded with a visual analogue scale (VAS) during provocative manoeuvres: palpation, resisted contraction and single leg squat. Results Positive Doppler US (within the distal end of the patellar tendon) was associated with higher pain on palpation (47±24.5 vs 18±11.4, p<0.01) and resisted static contraction (59±20.2 vs 27±12.5, p<0.001) compared with Doppler-negative subjects. No Doppler activity was found in the comparison group. VAS for palpation and resisted contraction of the athletes graded as stage 2 (51.1±22.0 and 60.0±21.2) were significantly higher than stage 3 (17.8±12.0 and 18.9±16.9) and stage 4 (15.0±7.1 and 25.0±7.1; p<0.01). Conclusions More painful OSD is associated with the presence of neo-vessels. This may be linked with a particular stage of ATT maturation and applied compressive forces. A Doppler ultrasound scan adds practical information to develop the care plan of the patient. PMID:22952406

  20. Multi-centre clinical study evaluating the efficacy of SonoVue (BR1), a new ultrasound contrast agent in Doppler investigation of focal hepatic lesions.

    Science.gov (United States)

    Leen, E; Angerson, W J; Yarmenitis, S; Bongartz, G; Blomley, M; Del Maschio, A; Summaria, V; Maresca, G; Pezzoli, C; Llull, J B

    2002-03-01

    SonoVue is a new ultrasound contrast agent, which consists of stabilised microbubbles of a sulphur hexafluoride gas. The aim of the study was to assess its efficacy in the Doppler investigation of focal hepatic lesions. Seventy patients with focal liver tumours were studied. Four doses (0.3, 0.6, 1.2 and 2.4 ml) of SonoVue were administered intravenously with at least 10 min delay between each injection. A complete colour/power and spectral Doppler imaging investigation of the lesions was performed at baseline pre-dosing and after each SonoVue injection. All examinations were recorded on SVHS videotapes. Baseline and post contrast videotapes were reviewed by the on-site (un-blinded) investigators and by two off-site blinded readers (a) to grade the global quality of the Doppler scans of the focal lesions vascularity and the normal parenchymal vessels (b) to measure the duration of clinically useful Doppler signal enhancement and (c) to determine the diagnostic accuracy and performance of the enhanced versus unenhanced scans using histopathology, tumour markers, CT and/or MR as the reference standard. A statistically significant improvement was observed at all four SonoVue doses in the off site assessment of global quality of the Doppler examination of tumoral and normal parenchymal vessels in comparison with the baseline (P SonoVue is effective in improving the display of tumoral vascularisation and may be useful in the characterisation of focal liver lesions.

  1. Influence of laser frequency noise on scanning Fabry-Perot interferometer based laser Doppler velocimetry

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2014-01-01

    n this work, we study the performance of a scanning Fabry-Perot interferometer based laser Doppler velocimeter (sFPILDV) and compare two candidate 1.5 um single-frequency laser sources for the system – a fiber laser (FL) and a semiconductor laser (SL). We describe a straightforward calibration...

  2. A multipoint feedback control system for scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Johnson, C.; Kress, R.; Roemer, R.; Hynynen, K.

    1987-01-01

    A multipoint feedback control system has been developed and tested for use with a scanned focussed ultrasound hyperthermia system. Extensive in-vivo tests (using a perfused organ model) have been made to evaluate the basic performance characteristics of the feedback control scheme for control of temperature in perfused media. The results of these tests are presented and compared with the predictions of a simulation routine. The control scheme was also tested in vivo using dogs' thighs and kidneys. Thigh experiments show the control scheme responds well to the affects of vasodilation and is able to maintain the targeted temperatures. In kidney experiments, where the rate of perfusion was controllable, the power adjusting algorithm successfully maintained uniform temperature distributions across regions of varying rates of perfusion. As a conclusion, the results show that this multipoint feedback controller scheme induces uniform temperature distributions when used with scanned focussed ultrasound systems

  3. Design and Development of a Scanning Airborne Direct Detection Doppler Lidar System

    Science.gov (United States)

    Gentry, Bruce; McGill, Matthew; Schwemmer, Geary; Hardesty, Michael; Brewer, Alan; Wilkerson, Thomas; Atlas, Robert; Sirota, Marcos; Lindemann, Scott

    2006-01-01

    In the fall of 2005 we began developing an airborne scanning direct detection molecular Doppler lidar. The instrument is being built as part of the Tropospheric Wind Lidar Technology Experiment (TWiLiTE), a three year project selected by the NASA Earth Sun Technology Office under the Instrument Incubator Program. The TWiLiTE project is a collaboration involving scientists and engineers from NASA Goddard Space Flight Center, NOAA ESRL, Utah State University Space Dynamics Lab, Michigan Aerospace Corporation and Sigma Space Corporation. The TWiLiTE instrument will leverage significant research and development investments made by NASA Goddard and it's partners in the past several years in key lidar technologies and sub-systems (lasers, telescopes, scanning systems, detectors and receivers) required to enable spaceborne global wind lidar measurement. These sub-systems will be integrated into a complete molecular direct detection Doppler wind lidar system designed for autonomous operation on a high altitude aircraft, such as the NASA WB57. The WB57 flies at an altitude of 18 km and from this vantage point the nadir viewing Doppler lidar will be able to profile winds through the full troposphere. The TWiLiTE integrated airborne Doppler lidar instrument will be the first demonstration of a airborne scanning direct detection Doppler lidar and will serve as a critical milestone on the path to a future spaceborne tropospheric wind system. In addition to being a technology testbed for space based tropospheric wind lidar, when completed the TWiLiTE high altitude airborne lidar will be used for studying mesoscale dynamics and storm research (e.g. winter storms, hurricanes) and could be used for calibration and validation of satellite based wind systems such as ESA's Aeolus Atmospheric Dynamics Mission. The TWiLiTE Doppler lidar will have the capability to profile winds in clear air from the aircraft altitude of 18 km to the surface with 250 m vertical resolution and < 2mls

  4. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  5. Metrological capabilities of Scanning Long Range Doppler Lidars

    Science.gov (United States)

    Loaec, Sophie; Boquet, Matthieu; Cariou, Jean-Pierre

    2013-04-01

    Many application areas are interested in getting wind measurements within the Planetary Boundary Layer (PBL) height, and with a relatively high accuracy. These applications include meteorology like PBL studies, air traffic safety like aircraft induced wake vortices and wind shears detection or wind farming like wind resources assessment. In order to answer these demands there are recent developments and deployments of long-range vertical profiler or fully hemispherical scanning wind lidars. To validate the measurements provided by such a system, it is possible to make inter-comparisons with a met mast at short distance and with wind profilers radar or sodar at longer distance. But, there are difficulties that may arise from the implementation of this kind of methodology because of the uncertainty related to the campaign set-up and the instruments used as reference. In that perspective Leosphere is developing a method to assess the accuracy of the Leosphere's lidars. In this presentation, we will give a detail description of the method and its results.

  6. Local Lorentz force and ultrasound Doppler velocimetry in a vertical convection liquid metal flow

    Science.gov (United States)

    Zürner, Till; Vogt, Tobias; Resagk, Christian; Eckert, Sven; Schumacher, Jörg

    2018-01-01

    We report velocity measurements in a vertical turbulent convection flow cell that is filled with the eutectic liquid metal alloy gallium-indium-tin by the use of local Lorentz force velocimetry (LLFV) and ultrasound Doppler velocimetry. We demonstrate the applicability of LLFV for a thermal convection flow and reproduce a linear dependence of the measured force in the range of micronewtons on the local flow velocity magnitude. Furthermore, the presented experiment is used to explore scaling laws of the global turbulent transport of heat and momentum in this low-Prandtl-number convection flow. Our results are found to be consistent with theoretical predictions and recent direct numerical simulations.

  7. The value of ultrasound and Doppler exams after 22 weeks of gestation for the diagnosis of obstetric and perinatal pathology in low-risk pregnancy

    Directory of Open Access Journals (Sweden)

    Safonova I.M.

    2016-03-01

    Full Text Available Purpose — determining the importance of sonographic and Doppler examination after 22 weeks of gestation for the diagnosis of obstetric and perinatal complications at pregnancy low risk. Patients and methods. 4580 pregnant women from low risk subpopulation with normal results of ultrasound screenings. After 22 weeks of gestation sonographic and Doppler studies of pregnancy were performed. Perinatal outcomes of were studied as well. Results. The incidence of pathological ultrasound changes after 22 weeks of gestation in women at low risk subpopulations was 9.8%. Сritical placental violations were found in 51/4580 women (1.13%. In early fetal growth retardation cases at 26–30 weeks of gestation (44/51 or 86.2% the outcomes of pregnancies were unfavorable. In 83.9% cases of placental noncritical violations there were clinically favorable perinatal outcomes. In isolated polyhydramnios favorable outcomes were observed in 61.3% of cases. The risk of intrapartum distress after normal results of the III trimester ultrasound was high: OR 25 (95% CI 29–21, RR 83 (95% CI 77–88. The risk of premature rupture of membranes at normal results of the III trimester ultrasound was also high: OR 35 (95% CI 41–29, RR 88 (95% CI 94–80. Despite the low overall rate (2.5% of identify of uterine artery Doppler changes more than half of women with such disorders had perinatally significant complications which were observed later. An important predictor of preeclampsia and perinatal complications in low-risk pregnancy can be considered a bilateral abnormal uterine artery Doppler in conjunction with early calcification of the placenta: OR 300 (95% CI 278–335, RR 75 (95% CI 71–79. Conclusions. Features revealed by US in the second half of low-risk pregnancy in 3.2% of cases «translate» low'risk pregnancy into the high'risk, and in 6.6% — into the indefinite risk pregnancy. Medical tactics changed less than in 1% of the cases on the basis of ultrasound

  8. Deep vein thrombosis of the lower limbs: A retrospective analysis of doppler ultrasound findings

    Directory of Open Access Journals (Sweden)

    Sanjay M Khaladkar

    2014-01-01

    Full Text Available Background: Deep venous thrombosis (DVT of lower limbs is one of the most common cause for the majority of deaths caused by pulmonary embolism. Many medical and surgical disorders are complicated by DVT. Most venous thrombi are clinically silent. B-mode and color Doppler imaging is needed for early diagnosis of DVT to prevent complications and sequalae of DVT. Aim and Objectives: The objectives of the following study were to evaluate the role of Doppler as an imaging modality in diagnosing DVT of lower limbs, to study the spectrum of findings on Doppler ultrasound in patients with DVT. Materials and Methods: Retrospective descriptive analysis of 78 patients of DVT diagnosed on Doppler. Results: Nearly 74% of the patients were males and 26% were females with majority belonging to fifth decade (26%. 75 (96.1% cases showed unilateral while 3 (3.9% cases showed bilateral lower limb involvement. In our study, predominant distribution of thrombus was found to be in above knee region with 69/78 (88.5% patients having thrombus in the superficial femoral vein. Popliteal vein was involved in 54/78 (69.2% patients. Complete thrombosis was observed in 54/78 (69% cases, while partial thrombosis was observed in 24/78 (31% cases. Subacute stage was seen in 42 cases (53.8%, acute stage in 23 cases (29.5% while chronic stage in 13 cases (16.7%. 71 cases (91% had multiple contiguous segmental involvement, whereas 7 cases (9% had isolated vein involvement. Conclusion: Color Doppler is useful in diagnosing DVT in symptomatic and at risk patients and provides a non-invasive method of investigation. It is also helpful in evaluating the site, extent and stage of thrombus.

  9. The diagnosis value of color doppler ultrasound in evaluating small renal carcinoma

    International Nuclear Information System (INIS)

    Chen Gaiyi

    2009-01-01

    Objective: To characterize the ultrasound and color doppler imaging of small renal carcinoma. Methods: Ultrasound and color doppler images by convex-probe and high frequency-probe of 24 patients with renal carcinoma confirmed by surgery and histology were analyzed retrospectively. Tumor echo, halo, internal blood flow and peripheral tumor blood flow were observed. Results: Tumor echo in 9 lesions was hyper-echo, in 4 was iso-echoic, in 10 was hypo-echo, and in 1 was echoless. Halo was detected in 9 tumors, and small cyst was detected in 5 tumors. By using the convex-probe, peripheral and internal blood flow signal in 24 tumors were observed. Spot blood follow was detected in 6 tumors, half-circularity blood follow in 18 tumors and no circularity blood follow. Detection rate of internal blood flow was 20.83%. By using the high frequency-probe in 21 tumors, spot blood was detected in 1 tumor, half-circularity blood follow in 14 tumors, circularity blood follow in 6 tumors. Detection rate of internal blood flow was 90.48%. It was not satisfied for high frequency-probe in 3 patients because of obesity. Accordance of the diagnosis by high frequency-probe ultrasound was 90.48% and 91.67% by CT (P > 0.05). Conclusion: Detection of renal carcinoma is sensitive by ultrasound. The high frequency-probe is significant sensitive to detect blood follow in renal carcinoma and is helpful to correct diagnosis of renal carcinoma. (authors)

  10. B-mode and Doppler ultrasound of chronic kidney disease in dogs and cats.

    Science.gov (United States)

    Bragato, Nathália; Borges, Naida Cristina; Fioravanti, Maria Clorinda Soares

    2017-12-01

    Ultrasound is the imaging test of choice for renal evaluation, because it provides information about the position, size, shape, internal architecture and hemodynamics of the kidneys without harming the patient. In chronic kidney disease, the main findings observed in B-mode ultrasound images are increased cortical echogenicity, loss of corticomedullary differentiation, reduced renal volume and irregular renal contour, and when these changes are associated, they are indicative of end-stage renal disease. However, the cause of kidney disease cannot be determined by ultrasonography, but must be confirmed by means of biopsy, although the presence of ultrasonographic changes indicative of the end-stage of the disease may contraindicate this procedure. The Doppler ultrasound test complements the ultrasonic B-mode examination and enables the assessment of renal perfusion based on a calculation of the hemodynamic indices, which are increased in cases of chronic kidney lesions, with higher values ​​in the most severe cases. Thus, ultrasound examinations are not only useful in diagnostics but also play an important role in defining the prognosis of patients with chronic kidney disease.

  11. Wrist ultrasound examination – scanning technique and ultrasound anatomy. Part 2: Ventral wrist

    Directory of Open Access Journals (Sweden)

    Cyprian Olchowy

    2017-06-01

    Full Text Available Ultrasound imaging of the musculoskeletal system is an important element of the diagnostic and therapeutic protocol. Clinical decisions, including those regarding surgical procedures, are often based solely on ultrasound imaging. However, detailed knowledge on the anatomy and a correct scanning technique are crucial for an accurate diagnosis. Modern ultrasonographic equipment allows obtaining detailed anatomical images of muscle tendons, ligaments, nerves and vessels of the carpal area. Ventral wrist ultrasound is one of the most common diagnostic procedures in patients with suspected carpal tunnel syndrome. Ventral wrist evaluation is also often performed in patients with wrist pain of unclear etiology, rheumatic diseases, wrist injuries or symptoms of ulnar neuropathy. The aim of this paper is to present ultrasound images with corresponding anatomical schemes. The technique of ultrasound examination of the ventral wrist along with practical guidance to help obtain highly diagnostic images is also discussed. The present paper is the second part of an article devoted to ultrasound anatomy and wrist ultrasound technique – the part discussing the dorsal side of the wrist was published in the Journal of Ultrasonography, Vol. 15, No 61. The following anatomical structures should be visualized during an ultrasound examination of the ventral wrist, both in the carpal tunnel as well as proximally and distally to it: four flexor digitorum superficialis tendons, four flexor digitorum profundus tendons, flexor pollicis longus, flexor carpi radialis tendon, median nerve and flexor retinaculum; in the carpal tunnel as well as proximally and distally to it: the ulnar nerve, ulnar artery and veins; the tendon of the flexor carpi ulnaris muscle; carpal joints.

  12. DOPPLER ULTRASOUND AND ANGIOGRAPHY OF THE VASCULATURE OF THE LIVER IN CHILDREN AFTER ORTHOTOPIC LIVER-TRANSPLANTATION - A PROSPECTIVE-STUDY

    NARCIS (Netherlands)

    KOK, T; PEETERS, PMJG; HEW, JM; MARTIJN, A; KOETSE, HA; BIJLEVELD, CMA; SLOOFF, MJH

    Despite the availability of Doppler ultrasound, angiography still forms part of the protocol for evaluating children after orthotopic liver transplantation (OLT) at our department. To investigate whether Doppler ultrasound is a reliable method for evaluating the patency of the hepatic artery, portal

  13. Development of a control algorithm for the ultrasound scanning robot (NCCUSR) using ultrasound image and force feedback.

    Science.gov (United States)

    Kim, Yeoun Jae; Seo, Jong Hyun; Kim, Hong Rae; Kim, Kwang Gi

    2017-06-01

    Clinicians who frequently perform ultrasound scanning procedures often suffer from musculoskeletal disorders, arthritis, and myalgias. To minimize their occurrence and to assist clinicians, ultrasound scanning robots have been developed worldwide. Although, to date, there is still no commercially available ultrasound scanning robot, many control methods have been suggested and researched. These control algorithms are either image based or force based. If the ultrasound scanning robot control algorithm was a combination of the two algorithms, it could benefit from the advantage of each one. However, there are no existing control methods for ultrasound scanning robots that combine force control and image analysis. Therefore, in this work, a control algorithm is developed for an ultrasound scanning robot using force feedback and ultrasound image analysis. A manipulator-type ultrasound scanning robot named 'NCCUSR' is developed and a control algorithm for this robot is suggested and verified. First, conventional hybrid position-force control is implemented for the robot and the hybrid position-force control algorithm is combined with ultrasound image analysis to fully control the robot. The control method is verified using a thyroid phantom. It was found that the proposed algorithm can be applied to control the ultrasound scanning robot and experimental outcomes suggest that the images acquired using the proposed control method can yield a rating score that is equivalent to images acquired directly by the clinicians. The proposed control method can be applied to control the ultrasound scanning robot. However, more work must be completed to verify the proposed control method in order to become clinically feasible. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Visual and laser Doppler perfusion scanning assessments of Kathon CG patch test reactions.

    Science.gov (United States)

    Bjarnason, B; Fischer, T

    1998-12-01

    Testing procedure for Kathon CG (Diagnostics AB, Tygelsjö, Sweden) is not standardized. To improve test results for Kathon CG. Eleven subjects were tested with Kathon CG patch tests applied from 6 to 96 hours. Tests were read visually and by a laser Doppler perfusion scanning technique at time points ranging from 6 to 240 hours. There were large differences in the perfusion profiles of subjects tested in identical fashion. Beginning reactions were detected earlier with the laser Doppler scanning than with the visual assessment technique. There was no obvious agreement between peak perfusion values of reactions and application times. Both assessment techniques were effective at distinguishing between positive and negative subjects at an adequate dose and application time. This distinction was possible using a shorter reading time with the laser Doppler scanning for all subjects. Six-hour applications were sufficient to detect all positive subjects so tested regardless of assessment technique. With that application time, positive and negative subjects were most effectively identified using long reading times regardless of assessment technique. The shortest application time used on all subjects, 24 hours, was effective and 6-hour applications with long reading times for all subjects so tested. Doses lower than 0.0040 mg/cm2 resulted in false-negative tests.

  15. Diagnosis of hepatoma using grayscale and Doppler ultrasound in patients with chronic liver disease

    Directory of Open Access Journals (Sweden)

    Idris S

    2011-10-01

    Full Text Available Wasim A Memon, Zishan Haider, Mirza Amanullah Beg, Muhammad Idris, Tanveer-ul-Haq, Waseem Akhtar, Sidra IdrisRadiology Department, Aga Khan University Hospital, Karachi, Pakistan Every author contributed equally to the workObjective: To determine the diagnostic accuracy of liver ultrasound for the detection of hepatoma in chronic liver disease (CLD patients by either taking histopathology or serum α-fetoprotein levels or a biphasic computed tomography (CT scan (whichever is available as the gold standard.Study design: Cross-sectional.Place and duration of study: Radiology Department, The Aga Khan University Hospital, Karachi, Pakistan, from January 2007 to January 2010.Methods: A total of 239 patients (156 males and 83 females with clinical suspicion or surveillance of hepatoma in CLD referred to the radiology department for ultrasound evaluation followed by either liver biopsy and histopathology or serum α-fetoprotein level or biphasic CT scan.Results: The sensitivity of ultrasound for hepatoma detection in CLD was 65%, specificity was 85%, and accuracy was 70%, and positive predictive value and negative predictive value were 92% and 45%, respectively.Conclusion: Ultrasound is a relatively quick, safe, reasonably accurate, and noninvasive imaging modality for the detection of hepatoma in CLD and can be complemented with clinical assessment of screening high-risk patients.Keywords: hepatoma, ultrasound, radiology, chronic liver disease

  16. Neovascularity in patellar tendinopathy and the response to eccentric training: a case report using Power Doppler ultrasound.

    Science.gov (United States)

    McCreesh, Karen M; Riley, Sara J; Crotty, James M

    2013-12-01

    This report describes the case of an amateur soccer player with chronic patellar tendinopathy who underwent ultrasound imaging before and after engaging in an 8-week programme of eccentric exercise. On initial assessment, greyscale ultrasound imaging demonstrated tendon thickening and reduced echogenicity, while Power Doppler imaging demonstrated a large amount of neovascularity. After 8 weeks of an eccentric loading programme, the patient reported significantly improved symptoms and functional scores, while follow-up imaging demonstrated improvement in the echo appearance of the tendon and complete resolution of the neovascularity. The association between neovascularity and symptoms in tendinopathy research is conflicting, with a paucity of research in the area of patellar tendinopathy. While further research is needed to clarify the significance of greyscale and Power Doppler ultrasound changes in relation to symptoms in patellar tendinopathy, ultrasound imaging was shown to be a useful adjunct to diagnosis and outcome assessment in this case. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2007-09-01

    Full Text Available Abstract Morbidity and mortality rates are higher in patients with severe left ventricular (LV systolic dysfunction and ECG-derived prolonged QRS interval than in those with normal QRS duration. QRS duration is currently used on the grounds that it reflects the presence of ventricular dyssynchrony. However, 30–40% of patients selected on the basis of a prolonged QRS do not receive benefit by cardiac resynchronization therapy (CRT since they do not show any significant inverse LV remodeling and QRS duration does not accurately distinguish responders to CRT. Consequently, mechanical dyssynchrony (particularly intra-ventricular dyssynchrony seems to be much more important than electrical dyssinchrony. Pre- and post-echocardiographic assessment should require the combination of conventional and specific applications ranging from M-mode and pulsed/continuous Doppler, to pulsed Tissue Doppler, the off-line analysis of colour Tissue Velocity Imaging, Strain Rate Imaging, and real time three-dimensional reconstruction However, there is not no consensus about the best approach and the best ultrasound parameter for selecting candidates to CRT and ECG representation of abnormal cardiac conduction still remains as the main criterion in guidelines. This review is a practical update of ultrasound methods and measurements of atrio-ventricular, inter-ventricular and intra-ventricular dyssynchrony and describes experiences which used either conventional Doppler echocardiography and more advanced techniques. By these experiences, the global amount of LV dyssynchrony seems to be critical: the greater intra-ventricular dyssynchrony, the higher the possibility of significant LV inverse remodeling. After CRT, it is necessary also to evaluate the optimal atrio-ventricular delay and ventricular-ventricular delay setting that maximizes LV systolic function.

  18. A New Ka-Band Scanning Radar Facility: Polarimetric and Doppler Spectra Measurements of Snow Events

    Science.gov (United States)

    Oue, M.; Kollias, P.; Luke, E. P.; Mead, J.

    2017-12-01

    Polarimetric radar analyses offer the capability of identification of ice hydrometeor species as well as their spatial distributions. In addition to polarimetric parameter observations, Doppler spectra measurements offer unique insights into ice particle properties according to particle fall velocities. In particular, millimeter-wavelength radar Doppler spectra can reveal supercooled liquid cloud droplets embedded in ice precipitation clouds. A Ka-band scanning polarimetric radar, named KASPR, was installed in an observation facility at Stony Brook University, located 22 km west of the KOKX NEXRAD radar at Upton, NY. The KASPR can measure Doppler spectra and full polarimetric variables, including radar reflectivity, differential reflectivity (ZDR), differential phase (φDP), specific differential phase (KDP), correlation coefficient (ρhv), and linear depolarization ratio (LDR). The facility also includes a micro-rain radar and a microwave radiometer capable of measuring reflectivity profiles and integrated liquid water path, respectively. The instruments collected initial datasets during two snowstorm events and two snow shower events in March 2017. The radar scan strategy was a combination of PPI scans at 4 elevation angles (10, 20, 45, and 60°) and RHI scans in polarimetry mode, and zenith pointing with Doppler spectra collection. During the snowstorm events the radar observed relatively larger ZDR (1-1.5 dB) and enhanced KDP (1-2 ° km-1) at heights corresponding to a plate/dendrite crystal growth regime. The Doppler spectra showed that slower-falling particles ( 1 m s-1). The weakly increased ZDR could be produced by large, faster falling particles such as quasi-spherical aggregates, while the enhanced KDP could be produced by highly-oriented oblate, slowly-falling particles. Below 2 km altitude, measurements of dual wavelength ratio (DWR) based on Ka and S-band reflectivities from the KASPR and NEXRAD radars were available. Larger DWR (>10 dB) suggested

  19. Thoracodorsal artery examination with doppler ultrasound in healthy volunteers in a level three hospital

    International Nuclear Information System (INIS)

    Vasquez Rangel, Wolfgang Ignacio; Daza, Gabriel Fernando; Escobar Rojas, William

    2011-01-01

    Introduction: The thoracodorsal artery is a branch of the subscapular artery, which in turn is a branch of the axillary artery. The importance of this artery is that it supplies the latissimus dorsi muscle, used as a muscle-skin flap for breast reconstruction after mastectomy, mainly in patients with poor local tissues, in particular after receiving radiotherapy. Objective: to describe the physical characteristics of the thoracodorsal artery using Doppler ultrasound evaluation in healthy volunteers at Hospital Universitario del Valle. Materials and methods: We conducted a descriptive pilot study, because, after reviewing the medical literature, we did not find any reports assessing the thoracodorsal artery with the use of Doppler ultrasound. Results: we evaluated 51 patients, 50.9% female. The average age of the patients was 28.78 years. the axillary, subscapular and thoracodorsal arteries were identified in all patients. The characteristics of the thoracodorsal artery were as follows: Diameter 1.88 mm, peak systolic velocity 28.45 cm/s, peak diastolic velocity 2.03 cm/s, resistance index 0.94, pulsatility index 4.02. Although the study did not include anthropometric measurements, we found that the artery was more conspicuous in patients with developed muscle mass and in patients with low adiposity. Conclusions: The thoracodorsal artery was identified in all patients, and ultrasound localization is a procedure that is easy to perform and provides vital information about the presence of the vascular pedicle required to perform a latissimus dorsi muscle-skin flap. Additional studies in post mastectomy patients are required in order to assess postoperative changes associated with the presence and physical characteristics of the thoracodorsal artery.

  20. Evaluation of the Wind Flow Variability Using Scanning Doppler Lidar Measurements

    Science.gov (United States)

    Sand, S. C.; Pichugina, Y. L.; Brewer, A.

    2016-12-01

    Better understanding of the wind flow variability at the heights of the modern turbines is essential to accurately assess of generated wind power and efficient turbine operations. Nowadays the wind energy industry often utilizes scanning Doppler lidar to measure wind-speed profiles at high spatial and temporal resolution.The study presents wind flow features captured by scanning Doppler lidars during the second Wind Forecast and Improvement Project (WFIP 2) sponsored by the Department of Energy (DOE) and National Oceanic and Atmospheric Administration (NOAA). This 18-month long experiment in the Columbia River Basin aims to improve model wind forecasts complicated by mountain terrain, coastal effects, and numerous wind farms.To provide a comprehensive dataset to use for characterizing and predicting meteorological phenomena important to Wind Energy, NOAA deployed scanning, pulsed Doppler lidars to two sites in Oregon, one at Wasco, located upstream of all wind farms relative to the predominant westerly flow in the region, and one at Arlington, located in the middle of several wind farms.In this presentation we will describe lidar scanning patterns capable of providing data in conical, or vertical-slice modes. These individual scans were processed to obtain 15-min averaged profiles of wind speed and direction in real time. Visualization of these profiles as time-height cross sections allows us to analyze variability of these parameters with height, time and location, and reveal periods of rapid changes (ramp events). Examples of wind flow variability between two sites of lidar measurements along with examples of reduced wind velocity downwind of operating turbines (wakes) will be presented.

  1. Gray scale ultrasound and isotope scanning: complementary techniques for imaging the liver

    International Nuclear Information System (INIS)

    Taylor, K.J.; Sullivan, D.; Rosenfield, A.T.; Gottschalk, A.

    1977-01-01

    Technical advances in gray scale ultrasound have led to better signal-to-noise ratios and improved resolution. A display of the texture of the liver is now possible, making ultrasound an important complementary technique to radisotope scanning. In the positive radioisotope scan, ultrasound permits differentiation of isotopically cold areas into neoplasms, benign cysts, and abscesses. In addition, when the radioisotope scan is equivocal, ultrasound is invaluable in differentiating normal variants from disease states. Dilated intrahepatic ducts can also be identified. Examples of the use of ultrasound in defining radioisotope abnormalities are presented

  2. Ultrasound scan in the diagnosis of neonatal renal candidiasis

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Torres, D.; Berbel, O.; Andres, V.

    2003-01-01

    To describe the most pertinent echographic findings regarding systemic and renal candidiasis in high-risk neonates. Echographic findings and clinical histories of 40 neonates in the neonatal intensive care unit were retrospectively analyzed. Thirty-eight presented systemic candidiasis with renal participation, while two showed only renal candidiasis. Ultrasound scans were performed using 7.5 MHz probes. Alterations in renal echo structure, presence of echogenic material without acoustic shadowing in the excretory system (mycetoma), presence of lithiasis, pyonephrosis and associated renal malformations were all evaluated. Ten patients presented renal alterations in ultrasound scan. Six children had originally shown increased eye-catching in the renal parenchyma which was resolved after medical treatment. Four children presented renal mycetoma, and in two there were renal malformations. Both of these exhibited a profile for pyonephrosis. One patient with renal mycetoma without urological abnormalities developed a lithiasis. Surgical intervention was unnecessary in all cases. The most common echographic findings in immature high-risk low-weight patients with systemic and renal candidiasis were alterations in the eye-catching of renal parenchyma and the presence of mycetoma. (Author) 22 refs

  3. Instrument configuration for dual-Doppler lidar coplanar scans: METCRAX II

    Science.gov (United States)

    Cherukuru, Nihanth Wagmi; Calhoun, Ronald; Lehner, Manuela; Hoch, Sebastian W.; Whiteman, C. David

    2015-01-01

    The second Meteor Crater Experiment (METCRAX II) was designed to study downslope-windstorm-type flows occurring at the Barringer Meteorite Crater in Arizona. Two Doppler wind lidars were deployed to perform a coplanar dual-Doppler lidar analysis to capture the two-dimensional (2-D) vertical structure of these flows in the crater basin. This type of analysis allows the flow to be resolved on a 2-D Cartesian grid constructed in the range height indicator scan overlap region. Previous studies have shown that the dominant error in the coplanar dual-Doppler analysis mentioned above is due to the under sampling of radial velocities. Hence, it is necessary to optimize the setup and choose a scan strategy that minimizes the under sampling of radial velocities and provides a good spatial as well as temporal coverage of these short-lived events. A lidar simulator was developed using a large Eddy simulation wind field to optimize the lidar parameters for METCRAX II field experiment. A retrieval technique based on the weighted least squares technique with weights calculated based on the relative location of the lidar range gate centers to the grid intersection point was developed. The instrument configuration was determined by comparing the simulator retrievals to the background wind field and taking into account the limitations of commercially available lidars.

  4. Apparent diffusion coefficient of renal parenchyma and color Doppler ultrasound of intrarenal arteries in patients with cirrhosis related renal dysfunction

    Directory of Open Access Journals (Sweden)

    Mohamed M Hefeda

    2014-12-01

    Conclusion: Liver cirrhosis, even in the presence of refractory ascites, did not affect the ADC value of renal parenchyma, however ADC value is affected in renal parenchyma of patients with hepato-renal syndrome. Duplex-Doppler ultrasound of intrarenal arteries enables the early detection of renal hemodynamic disturbances in patients with liver cirrhosis.

  5. Duplex ultrasound scanning of peripheral arterial disease of the lower limb

    DEFF Research Database (Denmark)

    Eiberg, Jonas Peter; Rasmussen, John Bøje Grønvall; Hansen, Marc Allan

    2010-01-01

    To assess the reliability and applicability of duplex ultrasound scanning (DUS) of lower limb arteries, compared with digital subtraction angiography (DSA), in patients with peripheral arterial disease (PAD)....

  6. ASSESSMENT OF FOETAL COMPROMISE BY DOPPLER ULTRASOUND INVESTIGATION OF THE FOETAL CIRCULATION

    Directory of Open Access Journals (Sweden)

    Bindu Philip

    2017-09-01

    Full Text Available BACKGROUND The condition in which the foetus does not reach its growth potential is called Intrauterine Growth Restricted (IUGR. The mothers who are generally healthy and well nourished, the incidence of IUGR is 3-5%. The incidence of IUGR is 15-20% or higher in a women population with hypertension or previous growth restricted foetus. The aim of the study is to assess foetal compromise by Doppler ultrasound investigation of the foetal circulation. MATERIALS AND METHODS This study is a prospective study conducted between November 2013 to November 2016 in the Department of Radiodiagnosis and imaging of Mount Zion Medical College, Kerala. A total of 50 singleton pregnancies with suspected IUGR pregnancy attending the outpatient ward of Obstetrics and Gynaecology. Inclusion Criteria- Pregnancies from 29 weeks to 42 weeks of gestation complicated by intrauterine growth restriction and who are ultrasound confirmed. In the first trimester, gestational age determination was estimated by history of menstruation or biometry of foetus. Exclusion Criteria- Patients who had multiple gestations, congenital anomalies and history of membranes rupture. All the patients in the study were subjected to clinical history in detail to assess the risk factors of IUGR pregnancy, biometry of ultrasound and amniotic fluid assessment followed by Doppler ultrasound evaluation of uterine arteries, umbilical artery, middle cerebral artery, descending foetal thoracic aorta, ductus venous and umbilical vein. RESULTS Majority of the patients were in the age group of 21-24 years. All the patients were in the age group of 19-30 years. 45% of antenatal mothers examined were between 28-31 weeks of gestational age, 35% were between 32-36 weeks of gestation, 20% were between 37-42 weeks of gestation age. 15 antenatal mothers had elevated uterine artery resistance index (30%, 12 antenatal mothers had persistent early diagnostic notch (24%, 11 antenatal mothers had elevated systolic

  7. Combined Lorentz force and ultrasound Doppler velocimetry in a vertical convection liquid metal flow

    Science.gov (United States)

    Zürner, Till; Vogt, Tobias; Resagk, Christian; Eckert, Sven; Schumacher, Jörg

    2017-11-01

    We report experimental studies on turbulent vertical convection flow in the liquid metal alloy gallium-indium-tin. Flow measurements were conducted by a combined use of local Lorentz force velocimetry (LLFV) and ultrasound Doppler velocimetry (UDV). It is known that the forced convection flow in a duct generates a force on the LLFV magnet system, that grows proportional to the flow velocity. We show that for the slower flow of natural convection LLFV retains this linear dependence in the range of micronewtons. Furthermore experimental results on the scaling of heat and momentum transport with the thermal driving are presented. The results cover a range of Rayleigh numbers 3 ×105 walls scales with Rez Ra0.45 . Additionally a Reynolds number based on the horizontal flow component is scaling as Rex Ra0.67 . These results agree well with numerical simulations and theoretical predictions. This work is funded by the Deutsche Forschungsgemeinschaft under Grant No. GRK 1567.

  8. A brain-computer interface based on bilateral transcranial Doppler ultrasound.

    Directory of Open Access Journals (Sweden)

    Andrew J B Myrden

    Full Text Available In this study, we investigate the feasibility of a BCI based on transcranial Doppler ultrasound (TCD, a medical imaging technique used to monitor cerebral blood flow velocity. We classified the cerebral blood flow velocity changes associated with two mental tasks--a word generation task, and a mental rotation task. Cerebral blood flow velocity was measured simultaneously within the left and right middle cerebral arteries while nine able-bodied adults alternated between mental activity (i.e. word generation or mental rotation and relaxation. Using linear discriminant analysis and a set of time-domain features, word generation and mental rotation were classified with respective average accuracies of 82.9%±10.5 and 85.7%±10.0 across all participants. Accuracies for all participants significantly exceeded chance. These results indicate that TCD is a promising measurement modality for BCI research.

  9. Modelflow Estimates of Stroke Volume Do Not Correlate With Doppler Ultrasound Estimates During Upright Posture

    Science.gov (United States)

    Ferguson, Connor R.; Lee, Stuart M. C.; Stenger, Michael B.; Platts, Steven H.; Laurie, Steven S.

    2014-01-01

    Orthostatic intolerance affects 60-80% of astronauts returning from long-duration missions, representing a significant risk to completing mission-critical tasks. While likely multifactorial, a reduction in stroke volume (SV) represents one factor contributing to orthostatic intolerance during stand and head up tilt (HUT) tests. Current measures of SV during stand or HUT tests use Doppler ultrasound and require a trained operator and specialized equipment, restricting its use in the field. BeatScope (Finapres Medical Systems BV, The Netherlands) uses a modelflow algorithm to estimate SV from continuous blood pressure waveforms in supine subjects; however, evidence supporting the use of Modelflow to estimate SV in subjects completing stand or HUT tests remain scarce. Furthermore, because the blood pressure device is held extended at heart level during HUT tests, but allowed to rest at the side during stand tests, changes in the finger arterial pressure waveform resulting from arm positioning could alter modelflow estimated SV. The purpose of this project was to compare Doppler ultrasound and BeatScope estimations of SV to determine if BeatScope can be used during stand or HUT tests. Finger photoplethysmography was used to acquire arterial pressure waveforms corrected for hydrostatic finger-to-heart height using the Finometer (FM) and Portapres (PP) arterial pressure devices in 10 subjects (5 men and 5 women) during a stand test while simultaneous estimates of SV were collected using Doppler ultrasound. Measures were made after 5 minutes of supine rest and while subjects stood for 5 minutes. Next, SV estimates were reacquired while each arm was independently raised to heart level, a position similar to tilt testing. Supine SV estimates were not significantly different between all three devices (FM: 68+/-20, PP: 71+/-21, US: 73+/-21 ml/beat). Upon standing, the change in SV estimated by FM (-18+/-8 ml) was not different from PP (-21+/-12), but both were significantly

  10. The value of Doppler ultrasound in predicting delayed graft function occurrence after kidney transplantation.

    Science.gov (United States)

    Mocny, Grzegorz; Bachul, Piotr; Chang, Ea-Sle; Kulig, Piotr

    The aim of this study was to assess the predictive value of blood flow velocity and vascular resistance measured by Doppler ultrasound in terms of pulsatility index (PI) and resistive index (RI) respectively, in the occurrence of delayed graft function (DGF) after kidney transplantation. This prospective study enrolled kidney transplant recipients operated from January 2005 to April 2009 in the 1st Department of General, Oncological and Gastroenterological Surgery, Jagiellonian University Medical College, Kraków, Poland. The medical records of 53 kidney transplant recipients from deceased donors were reviewed. PI and RI values of the graft arcuate artery were calculated immediately after blood flow restoration and on the 1st, 2nd, 4th and 8th post-operative day. DGF was observed in 20 patients (37.7%), while 33 patients (62.3%) had immediate restoration of the kidney function. The mean intraoperative values of RI and PI from patients with DGF were significantly higher in comparison to patients without DGF (0.9 vs. 0.74, p PI values remained stable and significantly higher in DGF group. The highest sensitivity of RI to predict DGF occurrence was observed intraoperatively and on the first postoperative day, with values of 77.8% and 72.2%, respectively. The risk of DGF occurrence with intraoperative RI value ≥0.9 increased by 13-fold, and with intraoperative PI value ≥1.9 by 12-fold. This increase was even more prominent during the first post-operative day with RI value ≥0.9 or PI value ≥1.9 with 19-fold increase in the risk of DGF occurrence. According to our study, the utilization of Doppler ultrasound with measurement of hemodynamic parameters (PI, RI), play a crucial role in predicting the outcomes of kidney transplantation.

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  12. Doppler ultrasound compatible plastic material for use in rigid flow models.

    Science.gov (United States)

    Wong, Emily Y; Thorne, Meghan L; Nikolov, Hristo N; Poepping, Tamie L; Holdsworth, David W

    2008-11-01

    A technique for the rapid but accurate fabrication of multiple flow phantoms with variations in vascular geometry would be desirable in the investigation of carotid atherosclerosis. This study demonstrates the feasibility and efficacy of implementing numerically controlled direct-machining of vascular geometries into Doppler ultrasound (DUS)-compatible plastic for the easy fabrication of DUS flow phantoms. Candidate plastics were tested for longitudinal speed of sound (SoS) and acoustic attenuation at the diagnostic frequency of 5 MHz. Teflon was found to have the most appropriate SoS (1376 +/- 40 m s(-1) compared with 1540 m s(-1) in soft tissue) and thus was selected to construct a carotid bifurcation flow model with moderate eccentric stenosis. The vessel geometry was machined directly into Teflon using a numerically controlled milling technique. Geometric accuracy of the phantom lumen was verified using nondestructive micro-computed tomography. Although Teflon displayed a higher attenuation coefficient than other tested materials, Doppler data acquired in the Teflon flow model indicated that sufficient signal power was delivered throughout the depth of the vessel and provided comparable velocity profiles to that obtained in the tissue-mimicking phantom. Our results indicate that Teflon provides the best combination of machinability and DUS compatibility, making it an appropriate choice for the fabrication of rigid DUS flow models using a direct-machining method.

  13. Doppler ultrasound study of portal hemodynamics in patients with Gaucher disease

    Directory of Open Access Journals (Sweden)

    Šarenac-Kovač Radmila

    2015-01-01

    Full Text Available Gaucher disease is a lysosomal storage disorder caused by a deficiency of the enzyme glucocerebrosidase and characterized by the presence of pathological macrophages laden with glucosylceramide. Hepatosplenomegaly is a common manifestation of Gaucher disease, but symptomatic portal hypertension is rarely seen. The study included 20 untreated adult patients with Gaucher disease (non-neuronopathic type 1 diagnosed with the presence of Gaucher cells in the bone marrow, and 20 healthy subjects as controls. The examination of patients included color Doppler ultrasonography (pulsed Doppler mode, resistive index (RI and Doppler perfusion index (DPI using a Toshiba Xario ultrasound machine and a convex array probe PVT-375AX (1.9-6 MHz with the objective of analyzing portal hemodynamics. Results showed that all patients had enlarged liver and spleen, and their average sizes were significantly larger than those in the healthy controls (liver: 17.04 vs.14.02 cm; spleen: 22.2 vs. 10.74 cm. DPI values were significantly different between patients and controls (0.15 vs. 0.21. Considering DPI <0.15 indicates arterial liver hypoperfusion and hypoxia, it can be concluded that a number of patients had a problem with liver oxygenation, which may be linked to the high angiotensin-converting enzyme (ACE levels obtained in the patients (339.42 U/L, 10 times greater than in control subjects. Since ACE is a potent vasoconstrictor produced by spleen macrophages in Gaucher disease, we can suppose that elevated ACE is associated with effects on the blood vessels of the liver and spleen. [Projekat Ministarstva nauke Republike Srbije, br. 175056

  14. Bone surface enhancement in ultrasound images using a new Doppler-based acquisition/processing method

    Science.gov (United States)

    Yang, Xu; Tang, Songyuan; Tasciotti, Ennio; Righetti, Raffaella

    2018-01-01

    Ultrasound (US) imaging has long been considered as a potential aid in orthopedic surgeries. US technologies are safe, portable and do not use radiations. This would make them a desirable tool for real-time assessment of fractures and to monitor fracture healing. However, image quality of US imaging methods in bone applications is limited by speckle, attenuation, shadow, multiple reflections and other imaging artifacts. While bone surfaces typically appear in US images as somewhat ‘brighter’ than soft tissue, they are often not easily distinguishable from the surrounding tissue. Therefore, US imaging methods aimed at segmenting bone surfaces need enhancement in image contrast prior to segmentation to improve the quality of the detected bone surface. In this paper, we present a novel acquisition/processing technique for bone surface enhancement in US images. Inspired by elastography and Doppler imaging methods, this technique takes advantage of the difference between the mechanical and acoustic properties of bones and those of soft tissues to make the bone surface more easily distinguishable in US images. The objective of this technique is to facilitate US-based bone segmentation methods and improve the accuracy of their outcomes. The newly proposed technique is tested both in in vitro and in vivo experiments. The results of these preliminary experiments suggest that the use of the proposed technique has the potential to significantly enhance the detectability of bone surfaces in noisy ultrasound images.

  15. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact

    Science.gov (United States)

    Simon, Julianna C.; Sapozhnikov, Oleg A.; Kreider, Wayne; Breshock, Michael; Williams, James C., Jr.; Bailey, Michael R.

    2018-01-01

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  16. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  17. Arteriovenous fistulae after renal biopsy: diagnosis and outcomes using Doppler ultrasound assessment.

    Science.gov (United States)

    Sosa-Barrios, R Haridian; Burguera, Victor; Rodriguez-Mendiola, Nuria; Galeano, Cristina; Elias, Sandra; Ruiz-Roso, Gloria; Jimenez-Alvaro, Sara; Liaño, Fernando; Rivera-Gorrin, Maite

    2017-12-20

    Percutaneous renal biopsy (PRB) is an important technique providing relevant information to guide diagnosis and treatment in renal disease. As an invasive procedure it has complications. Most studies up to date have analysed complications related to bleeding. We report the largest single-center experience on routine Doppler ultrasound (US) assessment post PRB, showing incidence and natural history of arteriovenous fistulae (AVF) post PRB. We retrospectively analysed 327 consecutive adult PRB performed at Ramon Cajal University Hospital between January 2011 and December 2014. All biopsies were done under real-time US guidance by a trained nephrologist. Routine Doppler mapping and kidney US was done within 24 h post biopsy regardless of symptoms. Comorbidities, full blood count, clotting, bleeding time and blood pressure were recorded at the time of biopsy. Post biopsy protocol included vitals and urine void checked visually for haematuria. Logistic regression was used to investigate links between AVF, needle size, correcting for potential confounding variables. 46,5% were kidney transplants and 53,5% were native biopsies. Diagnostic material was obtained in 90,5% (142 grafts and 154 native). Forty-seven AVF's (14.37%) were identified with routine kidney Doppler mapping, 95% asymptomatic (n = 45), 28 in grafts (18.4%) and 17 natives (9.7%) (p-value 0.7). Both groups were comparable in terms of comorbidities, passes, cylinders or biopsy yield (p-value NS). 80% were <1 cm in size and 46.6% closed spontaneously in less than 30 days (range 3-151). Larger AVF's (1-2 cm) took a mean of 52 days to closure (range 13-151). Needle size was not statistically significant factor for AVF (p-value 0.71). Contrary to historical data published, AVF's are a common complication post PRB that can be easily missed. Routine US Doppler mapping performed by trained staff is a cost-effective, non-invasive tool to diagnose and follow up AVF's, helping to assess management.

  18. 3D model assisted fully automated scanning laser Doppler vibrometer measurements

    Science.gov (United States)

    Sels, Seppe; Ribbens, Bart; Bogaerts, Boris; Peeters, Jeroen; Vanlanduit, Steve

    2017-12-01

    In this paper, a new fully automated scanning laser Doppler vibrometer (LDV) measurement technique is presented. In contrast to existing scanning LDV techniques which use a 2D camera for the manual selection of sample points, we use a 3D Time-of-Flight camera in combination with a CAD file of the test object to automatically obtain measurements at pre-defined locations. The proposed procedure allows users to test prototypes in a shorter time because physical measurement locations are determined without user interaction. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. The proposed method is illustrated with vibration measurements of an unmanned aerial vehicle

  19. Monitoring and Quantifying Particles Emissions around Industrial Sites with Scanning Doppler Lidar

    Science.gov (United States)

    Thobois, L.; Royer, P.; Parmentier, R.; Brooks, M.; Knoepfle, A.; Alexander, J.; Stidwell, P.; Kumar, R.

    2018-04-01

    Scanning Coherent Doppler Lidars have been used over the last decade for measuring wind for applications in wind energy [1], meteorology [2] and aviation [3]. They allow for accurate measurements of wind speeds up to a distance of 10 km based on the Doppler shift effect of aerosols. The signal reflectivity (CNR or Carrier-to-Noise Ratio) profiles can also be retrieved from the strength of the Lidar signal. In this study, we will present the developments of algorithm for retrieving aerosol optical properties like the relative attenuated backscatter coefficient and the mass concentration of particles. The use of these algorithms during one operational trial in Point Samson, Western Australia to monitor fugitive emissions over a mine will be presented. This project has been initiated by the Australian Department of Environment Regulations to better determine the impact of the Port on the neighboring town. During the trial in Summer, the strong impact of turbulence refractive index on Lidar performances has been observed. Multiple methodologies have been applied to reduce this impact with more or less success. At the end, a dedicated setup and configuration have been established that allow to properly observe the plumes of the mine with the scanning Lidar. The Lidar data has also been coupled to beta attenuation in-situ sensors for retrieving mass concentration maps. A few case of dispersion of plumes will be presented showing the necessity to combine both the wind and aerosol data.

  20. Application of scanning laser Doppler vibrometry for delamination detection in composite structures

    Science.gov (United States)

    Kudela, Pawel; Wandowski, Tomasz; Malinowski, Pawel; Ostachowicz, Wieslaw

    2017-12-01

    In this paper application of scanning laser Doppler vibrometry for delamination detection in composite structures was presented. Delamination detection was based on a guided wave propagation method. In this papers results from numerical and experimental research were presented. In the case of numerical research, the Spectral Element Method (SEM) was utilized, in which a mesh was composed of 3D spectral elements. SEM model included also a piezoelectric transducer. In the experimental research guided waves were excited using the piezoelectric transducer whereas the sensing process was conducted using scanning laser Doppler vibrometer (SLDV). Analysis of guided wave propagation and its interaction with delamination was based on a full wavefield approach. Attention was focused on interactions of guided waves with delamination manifested by A0 mode reflection, A0 mode entrapment, and S0/A0 mode conversion. Delamination was simulated by a teflon insert located between plies of composite material. Results of interaction with symmetrically and nonsymmetrical placed delamination (in respect to the composite sample thickness) were presented. Moreover, the authors investigated different size of delaminations. Damage detection was based on a new signal processing algorithm proposed by the authors. In this approach the weighted RMS was utilized selectively. It means that the summation in RMS formula was performed only for a specially selected time instances. Results for simple composite panels, panel with honeycomb core, and real stiffened composite panel from the aircraft were presented.

  1. Laser Ultrasound Spectroscopy Scanning for 3D Printed Parts

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, Guendalyn Kendra [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-04

    One of the challenges of additive manufacturing is quality control due to the possibility of unseen flaws in the final product. The current methods of inspection are lacking in detail, too slow for practical use, or unable to validate internal structure. This report examines the use of laser ultrasound spectroscopy in layer by layer scans of 3D printed parts as they are created. The result is fast and detailed quality control. An additional advantage of this method is the ability to cancel a print as soon as a defect is detected, therefore saving materials and time. This technique, though simple in concept, has been a challenge to implement. I discuss tweaking the 3D printer configuration, and finding the optimal settings for laser scanning small parts made of ABS plastic, as well as the limits of how small of a detail the laser can detect. These settings include the frequency of the ultrasonic transducer, the speed of the laser, and the distance from the laser to the part.

  2. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, Joanna M. [Division of Clinical Neurosciences, Western General Hospital, Crewe Road, Edinburgh EH4 2XU (United Kingdom)]. E-mail: jmw@skull.dcn.ed.ac.uk; Lewis, Steff [Division of Clinical Neurosciences, Western General Hospital, Crewe Road, Edinburgh EH4 2XU (United Kingdom)

    2005-11-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone.

  3. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    International Nuclear Information System (INIS)

    Wardlaw, Joanna M.; Lewis, Steff

    2005-01-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone

  4. Wavelet entropy of Doppler ultrasound blood velocity flow waveforms distinguishes nitric oxide-modulated states.

    Science.gov (United States)

    Agnew, Christina E; Hamilton, Paul K; McCann, Aaron J; McGivern, R Canice; McVeigh, Gary E

    2015-05-01

    Wavelet entropy assesses the degree of order or disorder in signals and presents this complex information in a simple metric. Relative wavelet entropy assesses the similarity between the spectral distributions of two signals, again in a simple metric. Wavelet entropy is therefore potentially a very attractive tool for waveform analysis. The ability of this method to track the effects of pharmacologic modulation of vascular function on Doppler blood velocity waveforms was assessed. Waveforms were captured from ophthalmic arteries of 10 healthy subjects at baseline, after the administration of glyceryl trinitrate (GTN) and after two doses of N(G)-nitro-L-arginine-methyl ester (L-NAME) to produce vasodilation and vasoconstriction, respectively. Wavelet entropy had a tendency to decrease from baseline in response to GTN, but significantly increased after the administration of L-NAME (mean: 1.60 ± 0.07 after 0.25 mg/kg and 1.72 ± 0.13 after 0.5 mg/kg vs. 1.50 ± 0.10 at baseline, p wavelet entropy had a spectral distribution from increasing doses of L-NAME comparable to baseline, 0.07 ± 0.04 and 0.08 ± 0.03, respectively, whereas GTN had the most dissimilar spectral distribution compared with baseline (0.17 ± 0.08, p = 0.002). Wavelet entropy can detect subtle changes in Doppler blood velocity waveform structure in response to nitric-oxide-mediated changes in arteriolar smooth muscle tone. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Role of qualitative elastography in ultrasound diagnosis of small benign Doppler nonvascular breast lesions in patients with hypothyroidism

    Directory of Open Access Journals (Sweden)

    A. B. Abduraimov

    2014-01-01

    Full Text Available The article describes a role of qualitative elastography in ultrasound diagnosis small benign Doppler nonvascular lesions in patients withhypothyroidism. In 2010–2013 the study included 319 women aged 20 to 85 years who underwent breast ultrasound (US with qualitative elastography and mammography. Breast US with qualitative elastography usage is advisable combination for small dopplerographic avascular mass larger than 5 mm, both in patients with and without hypothyroidism. Breast US with qualitative elastography is more effective in patients without hypothyroidism than in patients with hypothyroidism.

  6. Non-contact measurement of facial surface vibration patterns during singing by scanning laser Doppler vibrometer.

    Science.gov (United States)

    Kitamura, Tatsuya; Ohtani, Keisuke

    2015-01-01

    This paper presents a method of measuring the vibration patterns on facial surfaces by using a scanning laser Doppler vibrometer (LDV). The surfaces of the face, neck, and body vibrate during phonation and, according to Titze (2001), these vibrations occur when aerodynamic energy is efficiently converted into acoustic energy at the glottis. A vocalist's vibration velocity patterns may therefore indicate his or her phonatory status or singing skills. LDVs enable laser-based non-contact measurement of the vibration velocity and displacement of a certain point on a vibrating object, and scanning LDVs permit multipoint measurements. The benefits of scanning LDVs originate from the facts that they do not affect the vibrations of measured objects and that they can rapidly measure the vibration patterns across planes. A case study is presented herein to demonstrate the method of measuring vibration velocity patterns with a scanning LDV. The objective of the experiment was to measure the vibration velocity differences between the modal and falsetto registers while three professional soprano singers sang sustained vowels at four pitch frequencies. The results suggest that there is a possibility that pitch frequency are correlated with vibration velocity. However, further investigations are necessary to clarify the relationships between vibration velocity patterns and phonation status and singing skills.

  7. Ultrasound-Doppler technique for monitoring blood flow in the brachial artery compared with occlusion plethysmography of the forearm.

    Science.gov (United States)

    Byström, S; Jensen, B; Jensen-Urstad, M; Lindblad, L E; Kilbom, A

    1998-11-01

    Blood flow changes in the brachial artery of seven subjects during and after submaximal static handgrip contractions were measured by duplex Doppler ultrasound technique. These measurements were compared with the results of occlusion plethysmography, measured immediately (2-3 heartbeats) after. For the combined data from all measurements, a common calibration line could be drawn (linear regression, r=0.92). The flow measurements from the two methods were tested by a four-way analysis of variance and there was no significant difference between the methods during (static) exercise, indicating acceptable coherence. Occlusion plethysmography may well be used for monitoring forearm blood flow during conditions of static exercise. In addition, the cuff occlusion pressure of the plethysmograph (50 mmHg) decreased the blood flow of the brachial artery by approximately 28% as measured by duplex Doppler ultrasound.

  8. Follow-Up of Treatment Response With Dynamic Doppler Ultrasound in Raynaud Phenomenon.

    Science.gov (United States)

    Toprak, Ugur; Ozbalkan, Zeynep; Erdugan, Murat; Parlak, Selcuk; Sandıkcı, Sevinc Can; Kaya, Tunca; Şaylısoy, Suzan

    2017-12-01

    The purpose of this study was to investigate the role of flow parameters obtained with dynamic Doppler ultrasound in the objective follow-up of treatment response in patients with Raynaud phenomenon (RP). The study included 33 patients with newly diagnosed primary RP, 31 with secondary RP, and 26 healthy participants (control subjects). Both groups of patients with RP underwent sonography before and after treatment. The control group underwent sonography once. Baseline digital arterial diameter and flow volume were measured at room temperature. After cold provocation, diameter and flow volume were measured again, and flow starting time and flow normalizing time were recorded. Data were measured as mean (± SD) values. Baseline diameter did not significantly increase in either group after treatment (p > 0.05) (primary RP pretreatment, 0.79 ± 0.17 mm; posttreatment, 0.82 ± 0.19 mm; secondary RP pretreatment, 0.66 ± 0.13 mm; posttreatment, 0.68 ± 0.14 mm). Baseline flow volume increased significantly in both groups (p 0.05), but there was a significant increase in patients with secondary RP (p < 0.05) (primary RP pretreatment, 1.15 ± 2.27 minutes; posttreatment, 0.61 ± 1.41 minutes; secondary RP pretreatment, 3.13 ± 4.81 minutes; posttreatment, 1.58 ± 2.36 minutes). After treatment, flow volume normalizing time improved significantly in both groups (p < 0.01) (primary RP pretreatment, 7.24 ± 7.60 minutes; posttreatment, 3.84 ± 3.39 minutes; secondary RP pretreatment, 9.58 ± 8.49 minutes; posttreatment, 4.32 ± 3.56 minutes). Among patients with primary RP, the posttreatment flow starting time was similar to that in the control group. Despite improvements, all remaining parameters differed in the treatment group compared with the control group. Doppler ultrasound can be used effectively to monitor RP treatment. Blood flow volume can be measured without cold provocation to facilitate follow-up care of patients with RP.

  9. Up-to-date Doppler techniques for breast tumor vascularity: superb microvascular imaging and contrast-enhanced ultrasound.

    Science.gov (United States)

    Park, Ah Young; Seo, Bo Kyoung

    2018-04-01

    Ultrasonographic Doppler techniques have improved greatly over the years, allowing more sophisticated evaluation of breast tumor vascularity. Superb microvascular imaging (SMI) and contrast-enhanced ultrasound (CEUS) with second-generation contrast agents are two representative up-to-date techniques. SMI is a sensitive Doppler technique that adopts an intelligent filter system to separate low-flow signals from artifacts. With the development of second-generation contrast agents, CEUS has also emerged as a useful Doppler technique for evaluating tumor microcirculation. Both techniques can improve the diagnostic performance of gray-scale ultrasonography by providing vascular information useful not only for the morphologic assessment of microvessels, but also for the quantitative analysis of perfusion. In this review, we explain the imaging principles and previous research underlying these two vascular techniques, and describe our clinical experiences.

  10. Doppler ultrasound velocities and resistive indexes immediately after pediatric liver transplantation: normal ranges and predictors of failure.

    Science.gov (United States)

    Jamieson, Lucy H; Arys, Bo; Low, Gavin; Bhargava, Ravi; Kumbla, Surekha; Jaremko, Jacob L

    2014-07-01

    We sought to determine the ranges of Doppler ultrasound findings immediately after pediatric liver transplantation that are associated with successful outcomes or postoperative complications. This study included consecutive children who underwent Doppler ultrasound less than 48 hours after liver transplantation from 2001 to 2011. Operative reports and clinical outcome data were recorded. We had 110 patients (54% girls) with mean age at transplantation of 2.9 years (median, 1.3 years; range, 0-14 years) and a median follow-up interval of 3.5 years. Two pediatric radiologists reviewed ultrasound images in consensus. We computed descriptive statistics, interindex correlations, and analysis of variance. Twenty-four of 110 patients had a vascular complication, most commonly hepatic arterial thrombosis (seven patients). Compared with published adult normal values, normal pediatric Doppler parameters at postoperative day 1 trended toward higher normal velocities and resistive indexes (up to 0.95). Absent or low-velocity common hepatic artery flow less than 50 cm/s or a common hepatic artery resistive index less than 0.50 were significantly associated with hepatic artery thrombosis, whereas absent or low-velocity portal venous flow less than 30 cm/s or low-velocity hepatic venous flow less than 25 cm/s were significantly associated with vascular complications and a monotonic hepatic venous waveform was significantly associated with venous complications. Flow in a pediatric liver on the first day after transplantation is normally hyperdynamic, especially in the youngest transplant recipients, and, as a result, low velocities or resistive indexes are particularly concerning for complications. The pediatric-specific ranges of expected posttransplantation Doppler ultrasound findings presented in this article should assist in identifying normal variation and potentially life-threatening complications.

  11. Doppler ultrasound of the placenta and maternal and fetal vessels during normal gestation in captive agoutis (Dasyprocta prymnolopha, Wagler, 1831).

    Science.gov (United States)

    Sousa, Francisco C A; Pessoa, Gerson T; Moura, Laecio S; Rodrigues, Renan P S; Diniz, Anaemilia N; Souza, André B; Silva, Elzivânia G; Sanches, Marina P; Silva-Filho, Osmar F; Guerra, Porfirio C; Sousa, João M; Neves, Willams C; Alves, Flávio R

    2016-11-01

    The use of ultrasound for pregnancy monitoring is critical for the evaluation of hemodynamic parameters essential to fetal viability. In the present study, using B-mode and Doppler ultrasound, we characterized the placenta, subplacenta, maternal, and fetal vessels during normal gestation of healthy agoutis raised in captivity. In total, 30 agoutis were obtained from the Center for the Study and Preservation of Wild Animals, Center of Agricultural Sciences, Federal University of Piauí (Núcleo de Estudos e Preservação de Animais Silvestres-NEPAS, Centro de Ciências Agrárias-CCA, Universidade Federal do Piauí-UFPI). These animals were subjected to B-mode and Doppler ultrasound examinations to evaluate their maternal and fetal hemodynamic profiles. The placenta was located in the mesometrial region and had a discoid, ellipsoid, or globular aspect. With spectral Doppler, characteristic systolic and diastolic flow was observed in the umbilical artery. This flow increased during pregnancy. A cross-sectional view revealed a goblet-shaped placenta. The uteroplacental blood flow was characterized by a marked increase in systolic peak velocity during pregnancy, the presence of a rapid deceleration ramp, and a relatively high diastolic speed. The fetal aortic vascular flow was predominantly systolic and diastolic. The caudal vena cava blood flow was characterized by a systolic peak followed by a decreased diastolic wave throughout pregnancy. In the present study, we characterized the morphologic and hemodynamic interactions of the placenta/subplacenta with maternal and fetal vessels in agoutis at 30, 45, 60, 75, and 90 days gestation using B-mode and Doppler ultrasound. We determined the approximation and separation of the blood flow values of the umbilical artery, subplacental flow, uteroplacental artery, fetal aorta, and fetal vena cava. We believe these values may contribute to an understanding of the gestational biology and aid delivery prediction in this species

  12. Accuracy of Gray‑scale and Three‑dimensional Power Doppler ...

    African Journals Online (AJOL)

    Two-dimensional (2D) transabdominal gray-scale ultrasound and 3D power Doppler scans were done for studied women to confirm placental location and ... Chi-square test for qualitative data to detect the accuracy of 2D transabdominal gray-scale ultrasound and 3D power Doppler parameters in the diagnosis of MAP.

  13. The usefulness of color doppler ultrasound in diagnosing venous diseases of lower extremity: a comparison with DSA

    International Nuclear Information System (INIS)

    Zhang Yamei; Wang Shuzhi; Gu Jianpig; Chen Songwang; Huang Yan

    2009-01-01

    Objective: To evaluate the color Doppler ultrasound in diagnosing venous diseases of lower extremity, and to compare it with DSA.Methods: By using color Doppler ultrasound (CDUS) apparatus, two-dimensional spectrum, color Doppler flow image, pulse wave Doppler and Valsalva examination were performed in 48 patients with suspected venous diseases of lower extremity. The CDUS findings were compared with DSA findings. Results: Of 48 cases with suspected lower extremity venous diseases, deep vein thrombosis formation was confirmed in 27, among them 15 were accompanied with lower extremity deep venous valvular incompetence, 8 were complicated by lower extremity varicosity and 2 were associated with both conditions. Another one had cyst in the left popliteal fossa and popliteal venous thrombosis. Decreased blood flow in iliac veins was found in some cases. Pure lower extremity venous valvular incompetence was seen in 5 cases and pure lower extremity superficial varicosity in 6 cases. Six cases suffered both valvular incompetence and superficial varicosity. CDUS showed normal findings in 4 cases, of them DSA demonstrated compressed iliac vein in 2. When taking DSA as golden standard, the accuracy of CDUS was 95.83%. By using the uniformity test, Kappa value was 0.65. Conclusion: CDUS is of great clinical usefulness in diagnosing venous diseases of lower extremity as well as in evaluating the therapeutic effect. (authors)

  14. Comparison of IOL Master contact and immersion A-scan ultrasound measurements of anterior chamber depth

    Directory of Open Access Journals (Sweden)

    Min Xu

    2015-07-01

    Full Text Available AIM: To compare the results of IOL Master, contact and immersion A-scan ultrasound measurements for anterior chamber depth(ACD, and evaluate the difference and consistency.METHODS:Fifty-eight cases(98 eyeswith age-related cataract during July to October in 2013 did the A-scan ultrasound with contact and immersion measurements and IOL Master to get the results of ACD. Difference in measurements between methods was assessed using the variance analysisi. Consistency was assessed using Bland-Altman.RESULTS: The ACD measured by IOL Master was 2.31~3.90mm, the mean was 3.03±0.38mm. The ACD measured by contact A-scan ultrasound was 1.51~4.06mm, the mean was 2.88±0.56mm. The ACD measured by immersion A-scan ultrasound was 1.99~4.17mm, the mean was 3.17±0.38mm. The results of IOL Master and contact A-scan ultrasound had statistical differences(P=0.022P=0.031P=0.000CONCLUSION: The rank of ACD of patients with cataract is immersion A-scan ultrasound, IOL Master and contact A-scan ultrasound. The consistency is poor, and the three methods can't be interchanged clinically.

  15. Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice

    Science.gov (United States)

    Price, Anthony N.; Jackson, Laurence H.; Taylor, Valerie; David, Anna L.; Lythgoe, Mark F.; Stuckey, Daniel J.

    2017-01-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one‐dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high‐temporal‐resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user‐independent technique. Here, we investigated the performance of high‐temporal‐resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in‐house, high‐temporal‐resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom‐made, open‐source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high‐frequency, pulsed‐wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high‐temporal‐resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high‐temporal‐resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high‐temporal‐resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. PMID:28643891

  16. Direct comparison of high-temporal-resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice.

    Science.gov (United States)

    Roberts, Thomas A; Price, Anthony N; Jackson, Laurence H; Taylor, Valerie; David, Anna L; Lythgoe, Mark F; Stuckey, Daniel J

    2017-10-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  17. Effect of low level laser therapy on revascularization of free gingival graft using ultrasound Doppler flowmetry

    Directory of Open Access Journals (Sweden)

    Lalitha T. Arunachalam

    2014-01-01

    Full Text Available Low level laser therapy (LLLT is widely used during the post-operative period to accelerate the healing process. It promotes beneficial biological action on neovascularization with anti-inflammatory and analgesic effects. Two systemically healthy patients with Miller′s grade II recession on 33 and 41, respectively, were treated with free gingival graft. After surgery, second patient received LLLT using a 830 nm diode laser, with output power of 0.1 W on the first day half hour following surgery, on the third day, seventh day, and lastly on the ninth day. Both the patients were asked to assess the pain on second, fourth and tenth day using a Numerical Rating Scale and revascularization of the grafted area was assessed using a color Doppler ultrasound imaging on the fourth and the ninth day. Neovascularization was noted in both the patients but the second patient elicited marked increase in vascularity on the fourth as well as the tenth day and drastic reduction in pain on day four, with no change on the tenth day. The results showed that LLLT was an effective adjunctive treatment in promoting reevascularization and pain control during early healing of free gingival graft.

  18. Use of Doppler ultrasound in galen vein aneurysm diagnosis in newborns and adults

    International Nuclear Information System (INIS)

    Calvo Lopez, M.J.; Lopez Barrio, A.M.

    1995-01-01

    Five cases of Galen's vein aneurysm (GVA) are reported, four occurring in newborns and one in an adult. The newborns presented anatomical differences: two GVA were located on the midline and the other two were lateralized toward the left hemisphere. All cases presented increased ventricular volume, which was less evident with those aneurysms that were situated toward the left of the midline. In three cases, associated brain atrophy was detected, being generalized in two patients and confined to left hemisphere, the site of the malformation, in the third. In the four pediatric patients, Doppler ultrasound (DU) made it possible to identify the lesion and detect the presence of high amplitude and somewhat turbulent venous flow within it. This finding is characteristic of the lesion and contributes to its identification in most of its afferent vessels, which presented high amplitudes, with elevated systolic and diastolic velocities and low resistance index (IR). In the adult patient, it disclosed and increased lumen of the cervical arteries, with high flow rate of low resistance. DU is a valid method in the initial identification of GVA, permitting a correct diagnosis in pediatric cases and serving as a pre diagnostic aid in the adult patient. (Author) 15 refs

  19. A search for arteriovenous anastomoses in human skin using ultrasound Doppler.

    Science.gov (United States)

    Bergersen, T K

    1993-02-01

    The possible existence of arteriovenous anastomoses (AVAs) in skin regions of the head and thorax has been investigated using the synchronous vasomotion of the AVAs. Simultaneous pairs of blood velocity recordings were made using pulsed, bidirectional Doppler ultrasound. In each pair of registrations, blood velocity was recorded in a reference artery supplying a skin area known to contain AVAs (the radial artery) together with one of four other arteries investigated, i.e. the facial artery, the angular artery, the temporal artery, and the cutaneous branches of the lateral thoracic artery. The typical large, regular fluctuations in blood velocities caused by synchronous vasomotion in the AVAs in the skin of the hand and fingers were observed invariably in the radial artery. Similar flow variations were found in the angular artery. The fluctuations in this and the radial artery were, in turn, found to be synchronous. However, we have not been able to find the flow pattern characteristic of AVA vasomotion in the temporal artery or in the cutaneous branches of the lateral thoracic artery. These results show that the skin area of the nose supplied by the angular artery contains AVAs. These AVAs partly may explain the important role of face skin in temperature regulation. These results also support the earlier assumptions that there are no or very few AVAs in the skin areas supplied by the temporal artery and the cutaneous branches of the lateral thoracic artery.

  20. Does pre- and post-angioplasty Doppler ultrasound evaluation help in predicting vascular access outcome?

    Science.gov (United States)

    Guedes-Marques, Maria; Maia, Pedro A; Neves, Fernando; Ferreira, Aníbal; Cruz, João; Carvalho, Dulce; Oliveira, Carlos; Barreto, Carlos; Carvalho, Telmo; Ponce, Pedro

    2016-11-02

    Kidney Disease - Improving Global Outcomes (KDIGO) recommends post-percutaneous transluminal angioplasty (PTA) access blood flow (ABF) improvement predicts vascular access (VA) outcome. Secondary: compare Doppler ultrasound (DU) and angiography diagnostic accuracy; determine how other factors predict outcome. Eighty patients. DU evaluation performed pre- and post-PTA. Several parameters recorded. Secondary patency verified after 6 months. Initial ABF 537 ± 248 mL/min; final ABF 1013 ± 354 mL/min. Number and location of stenosis was highly correlated between DU and angiography (p30% associated to better survival, p 0.038. Initial ABF0.05). A >2-fold ABF increase had no significant impact on fistulas (p>0.05) but was significantly associated with worst outcomes in grafts (23.1% vs. 73.5%, p 0.009). Grafts had lower survival (HR 3.3, p 0.034). Although less accurate for central lesions, DU has a key role on VA surveillance, allowing a morphologic and hemodynamic assessment. Angioplasty is effective in preserving VA; however, it may increase restenosis due to accelerated neointimal hyperplasia. Current parameters are not useful. Trials addressing this issue are needed.

  1. High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence

    Directory of Open Access Journals (Sweden)

    Anthony S. Podkowa

    2018-02-01

    Full Text Available The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of ± 300 mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow.

  2. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study

    International Nuclear Information System (INIS)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F.

    2000-01-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  3. The application of laparoscopic Doppler ultrasound during laparoscopic varicocelectomy in infertile men

    Directory of Open Access Journals (Sweden)

    Li-Qiang Guo

    2017-01-01

    Full Text Available The aim of this study is to evaluate the benefits of laparoscopic Doppler ultrasound (LDU application during laparoscopic varicocelectomy (LV, and to compare the surgical outcomes and complications between LDU-assisted LV (LDU-LV and conventional LV for infertile patients with varicoceles; 147 infertile patients were randomly divided into two groups. Operative and postoperative parameters, semen parameters, and the pregnancy rate were compared. There were no differences in baseline demographics. The operative time was significantly longer in LDU-LV group than LV group. The incidence of postoperative hydrocele was 1.4% (1/72 in LDU-LV group versus 10.7% (8/75 in LV group, which showed a significant difference (P 0.05. In conclusion, compared with LV, LDU-LV could safely and effectively ligate all spermatic veins and preserve spermatic arteries without leading to high varicocele recurrence and postoperative hydrocele. Given the benefits that sperm counts as well as sperm motility favoring LDU-LV, we recommend that LDU should be routinely used as an effective tool to improve outcomes and safety of laparoscopic varicocelectomy.

  4. Estimation of the viscoelastic properties of vessel walls using a computational model and Doppler ultrasound

    International Nuclear Information System (INIS)

    Balocco, Simone; Basset, Olivier; Courbebaisse, Guy; Cachard, Christian; Boni, Enrico; Tortoli, Piero; Frangi, Alejandro F

    2010-01-01

    Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.

  5. Doppler ultrasound measurement of resistance index in the diagnosis of prostate cancer.

    Science.gov (United States)

    Huang, Wei; Cen, Son; Kang, Xin-Li; Wang, Wei Fu; Wang, Yang; Chen, Xiang

    2015-01-01

    Prostate cancer (PCa) remains the second leading cause of cancer diagnosis worldwide. Early diagnosis and treatment of PCa is critical since the long-term prognosis is excellent in patients with tumors confined to the prostate gland. The current meta-analysis investigates the diagnostic value of resistive index (RI) measurement using color Doppler ultrasound in patients with PCa. Electronic literature databases were exhaustively searched for relevant studies published prior to May 31, 2014. Nine studies met our predetermined inclusion criteria for the present meta-analysis. The methodologic quality of the selected studies was independently assessed by 2 reviewers based on Quality Assessment of Diagnostic Accuracy Studies tool. Our meta-analysis results showed that RI values were significantly higher in malignant prostate tissues compared to normal prostate tissues (standardized mean difference [SMD] 0.42, 95% confidence interval [CI] 0.12~0.73, p = 0.007) and benign prostate tissues (SMD 0.41, 95% CI 0.26~0.56, pbased on the diagnostic instruments used revealed that RI values were accurate in diagnosis of PCa when compared between malignant tissue vs normal tissue and malignant tissue vs benign tissue (all pvalues in diagnosis of PCa.

  6. An online three-class Transcranial Doppler ultrasound brain computer interface.

    Science.gov (United States)

    Goyal, Anuja; Samadani, Ali-Akbar; Guerguerian, Anne-Marie; Chau, Tom

    2016-06-01

    Brain computer interfaces (BCI) can provide communication opportunities for individuals with severe motor disabilities. Transcranial Doppler ultrasound (TCD) measures cerebral blood flow velocities and can be used to develop a BCI. A previously implemented TCD BCI system used verbal and spatial tasks as control signals; however, the spatial task involved a visual cue that awkwardly diverted the user's attention away from the communication interface. Therefore, vision-independent right-lateralized tasks were investigated. Using a bilateral TCD BCI, ten participants controlled online, an on-screen keyboard using a left-lateralized task (verbal fluency), a right-lateralized task (fist motor imagery or 3D-shape tracing), and unconstrained rest. 3D-shape tracing was generally more discernible from other tasks than was fist motor imagery. Verbal fluency, 3D-shape tracing and unconstrained rest were distinguished from each other using a linear discriminant classifier, achieving a mean agreement of κ=0.43±0.17. These rates are comparable to the best offline three-class TCD BCI accuracies reported thus far. The online communication system achieved a mean information transfer rate (ITR) of 1.08±0.69bits/min with values reaching up to 2.46bits/min, thereby exceeding the ITR of previous online TCD BCIs. These findings demonstrate the potential of a three-class online TCD BCI that does not require visual task cues. Copyright © 2016 Elsevier Ireland Ltd and Japan Neuroscience Society. All rights reserved.

  7. Non-contact measurement of facial surface vibration patterns during singing by scanning laser Doppler vibrometer

    Directory of Open Access Journals (Sweden)

    Tatsuya eKitamura

    2015-11-01

    Full Text Available This paper presents a method of measuring the vibration patterns onfacial surfaces by using a scanning laser Doppler vibrometer(LDV. The surfaces of the face, neck, and body vibrate duringphonation and, according to Titze (2001, these vibrations occur whenaerodynamic energy is efficiently converted into acoustic energy atthe glottis. A vocalist's vibration velocity patterns may thereforeindicate his or her phonatory status or singing skills. LDVs enablelaser-based non-contact measurement of the vibration velocity anddisplacement of a certain point on a vibrating object, and scanningLDVs permit multipoint measurements. The benefits of scanning LDVsoriginate from the facts that they do not affect the vibrations ofmeasured objects and that they can rapidly measure the vibrationpatterns across planes. A case study is presented herein todemonstrate the method of measuring vibration velocity patterns with ascanning LDV. The objective of the experiment was to measure thevibration velocity differences between the modal and falsettoregisters while three professional soprano singers sang sustainedvowels at four pitch frequencies. The results suggest that there is apossibility that pitch frequency are correlated with vibrationvelocity. However, further investigations are necessary to clarify therelationships between vibration velocity patterns and phonation statusand singing skills.

  8. Electrostatic forward-viewing scanning probe for Doppler optical coherence tomography using a dissipative polymer catheter.

    Science.gov (United States)

    Munce, Nigel R; Mariampillai, Adrian; Standish, Beau A; Pop, Mihaela; Anderson, Kevan J; Liu, George Y; Luk, Tim; Courtney, Brian K; Wright, Graham A; Vitkin, I Alex; Yang, Victor X D

    2008-04-01

    A novel flexible scanning optical probe is constructed with a finely etched optical fiber strung through a platinum coil in the lumen of a dissipative polymer. The packaged probe is 2.2 mm in diameter with a rigid length of 6mm when using a ball lens or 12 mm when scanning the fiber proximal to a gradient-index (GRIN) lens. Driven by constant high voltage (1-3 kV) at low current (probe oscillates to provide wide forward-viewing angle (13 degrees and 33 degrees with ball and GRIN lens designs, respectively) and high-frame-rate (10-140 fps) operation. Motion of the probe tip is observed with a high-speed camera and compared with theory. Optical coherence tomography (OCT) imaging with the probe is demonstrated with a wavelength-swept source laser. Images of an IR card as well as in vivo Doppler OCT images of a tadpole heart are presented. This optomechanical design offers a simple, inexpensive method to obtain a high-frame-rate forward-viewing scanning probe.

  9. Reliability of laser Doppler, near-infrared spectroscopy and Doppler ultrasound for peripheral blood flow measurements during and after exercise in the heat.

    Science.gov (United States)

    Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R

    2017-09-01

    This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2  = 0.062) and TOI (r 2  = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.

  10. Doppler ultrasound findings in healthy wrists and finger joints before and after use of two different contrast agents

    Science.gov (United States)

    Terslev, L; Torp-Pedersen, S; Bang, N; Koenig, M; Nielsen, M; Bliddal, H

    2005-01-01

    Objective: To examine the effect of contrast agents on Doppler ultrasound findings in the synovial membrane in the wrist and fingers of healthy volunteers. Material and methods: Eleven healthy subjects were included in the study (5 women and 6 men, mean age 38 years, range (20–60)). They had no clinical signs of inflammatory or degenerative joint diseases. A total of 66 joints were examined—6 joints for each subject: wrist and metacarpophalangeal (MCP) joints 1–5—before contrast injection and after Levovist and SonoVue injection with a 30 minute interval. Results: Colour Doppler activity was detected in 10/55 (18%) MCP joints before contrast injection and in 29/55 (53%) and 28/55 (51%) joints after Levovist (pSonoVue injection (p = 0.0001), respectively. A significant increase in Doppler activity in the radial (pSonoVue injections. With spectral Doppler no difference was found in the resistive index (RI) in the vessels measured before as compared with those only detected after contrast injection. Conclusion: The number of joints with colour Doppler activity in healthy volunteers was increased by the use of contrast agents. No changes in RI were detected. The value of contrast agents remains to be demonstrated in inflammatory diagnostics. PMID:15897304

  11. Exploring the vascular smooth muscle receptor landscape in vivo: ultrasound Doppler versus near-infrared spectroscopy assessments.

    Science.gov (United States)

    Ives, Stephen J; Fadel, Paul J; Brothers, R Matthew; Sander, Mikael; Wray, D Walter

    2014-03-01

    Ultrasound Doppler and near-infrared spectroscopy (NIRS) are routinely used for noninvasive monitoring of peripheral hemodynamics in both clinical and experimental settings. However, the comparative ability of these methodologies to detect changes in microvascular and whole limb hemodynamics during pharmacological manipulation of vascular smooth muscle receptors located at varied locations within the arterial tree is unknown. Thus, in 10 healthy subjects (25 ± 2 yr), changes in resting leg blood flow (ultrasound Doppler; femoral artery) and muscle oxygenation (oxyhemoglobin + oxymyoglobin; vastus lateralis) were simultaneously evaluated in response to intra-arterial infusions of phenylephrine (PE, 0.025-0.8 μg·kg(-1)·min(-1)), BHT-933 (2.5-40 μg·kg(-1)·min(-1)), and angiotensin II (ANG II, 0.5-8 ng·kg(-1)·min(-1)). All drugs elicited significant dose-dependent reductions in leg blood flow and oxyhemoglobin + oxymyoglobin. Significant relationships were found between ultrasound Doppler and NIRS changes across doses of PE (r(2) = 0.37 ± 0.08), BHT-933 (r(2) = 0.74 ± 0.06), and ANG II (r(2) = 0.68 ± 0.13), with the strongest relationships evident with agonists for receptors located preferentially "downstream" in the leg microcirculation (BHT-933 and ANG II). Analyses of drug potency revealed similar EC50 between ultrasound Doppler and NIRS measurements for PE (0.06 ± 0.02 vs. 0.10 ± 0.01), BHT-933 (5.0 ± 0.9 vs. 4.5 ± 1.3), and ANG II (1.4 ± 0.8 vs. 1.3 ± 0.3). These data provide evidence that both ultrasound Doppler and NIRS track pharmacologically induced changes in peripheral hemodynamics and are equally capable of determining drug potency. However, considerable disparity was observed between agonist infusions targeting different levels of the arterial tree, suggesting that receptor landscape is an important consideration for proper interpretation of hemodynamic monitoring with these methodologies.

  12. Characterization of cutaneous vascular lesions by Doppler ultrasound as an adjunct method for diagnosis and classification in the Hospital Nacional de Ninos: September 2007-June 2008

    International Nuclear Information System (INIS)

    Benavides Sanchez, Milton Mauricio

    2010-01-01

    The sonographic features and the Doppler valuation are characterized and studied in the service of ultrasound of the Hospital Nacional de Ninos in the study period September 2007 - June 2008. The documented findings are correlated in each lesion with the clinical diagnosis by the attending physician. Injuries are classified based on data obtained by Doppler valuation. The classification system currently accepted is used. A basic study protocol is established by Doppler ultrasound to provide enough information and that systematically vascular lesions are evaluated [es

  13. A novel two-axis micromechanical scanning transducer for handheld 3D ultrasound and photoacoustic imaging

    Science.gov (United States)

    Huang, Chih-Hsien; Zou, Jun

    2016-03-01

    This paper reports the development of a new two-axis micromechanical scanning transducer for handheld 3D ultrasound imaging. It consists of a miniaturized single-element ultrasound transducer driven by a unique 2-axis liquid-immersible electromagnetic microactuator. With a mechanical scanning frequency of 19.532 Hz and an ultrasound pulse repetition rate of 5 kHz, the scanning transducer was scanned along 60 concentric paths with 256 detection points on each to simulate a physical 2D ultrasound transducer array of 60 × 256 elements. Using the scanning transducer, 3D pulse-echo ultrasound imaging of two silicon discs immersed in water as the imaging target was successfully conducted. The lateral resolution of the 3D ultrasound image was further improved with the synthetic aperture focusing technique (SAFT). The new two-axis micromechanical scanning transducer doesn't require complex and expensive multi-channel data acquisition (DAQ) electronics. Therefore, it could provide a new approach to achieve compact and low-cost 3D ultrasound and photoacoustic imaging systems, especially for handheld operations.

  14. Pattern of Ultrasound Scanning in Owerri South Eastern Nigeria ...

    African Journals Online (AJOL)

    BACKGROUND: The gynaecologist is called upon daily to diagnose pelvic pathologies. Ultrasound is a useful, safe and widely used method of investigation of such problems. OBJECTIVE: To determine the indications and findings of pelvic ultrasound in Owerri, South Eastern Nigeria. METHOD: Two hundred and fifty ...

  15. PE-CMOS based C-scan ultrasound for foreign object detection in soft tissue.

    Science.gov (United States)

    Liu, Chu-Chuan; Lo, Shih-Chung Ben; Freedman, Matthew T; Lasser, Marvin E; Kula, John; Sarcone, Anita; Wang, Yue

    2010-01-01

    In this paper, we introduce a C-scan ultrasound prototype and three imaging modalities for the detection of foreign objects inserted in porcine soft tissue. The object materials include bamboo, plastics, glass and aluminum alloys. The images of foreign objects were acquired using the C-scan ultrasound, a portable B-scan ultrasound, film-based radiography, and computerized radiography. The C-scan ultrasound consists of a plane wave transducer, a compound acoustic lens system, and a newly developed ultrasound sensor array based on the complementary metal-oxide semiconductor coated with piezoelectric material (PE-CMOS). The contrast-to-noise ratio (CNR) of the images were analyzed to quantitatively evaluate the detectability using different imaging modalities. The experimental results indicate that the C-scan prototype has better CNR values in 4 out of 7 objects than other modalities. Specifically, the C-scan prototype provides more detail information of the soft tissues without the speckle artifacts that are commonly seen with conventional B-scan ultrasound, and has the same orientation as the standard radiographs but without ionizing radiation.

  16. Monostatic coaxial 1.5 μm laser Doppler velocimeter using a scanning Fabry-Perot interferometer

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2013-01-01

    We present a laser Doppler velocimeter (LDV) in monostatic coaxial arrangement consisting of off-the-shelf telecom-grade components: a single frequency laser (wavelength λ = 1.5 μm) and a high-finesse scanning Fabry-Perot interferometer (sFPI). In contrast to previous 1.5 μm LDV systems based...

  17. Noninvasive measurement of acoustic field inside mother's uterus generated by ultrasound scanning

    Science.gov (United States)

    Antonets, V. A.; Kazakov, V. V.

    2015-07-01

    Sounds in the audible range arising in mother's uterus during conventional ultrasound scanning were recorded noninvasively for the first time. It was found that their level is comparable with the level of spoken language.

  18. Evaluation of the repeatability of ultrasound scanning for detection of feline polycystic kidney disease.

    Science.gov (United States)

    Wills, Sheila J; Barrett, Esther L; Barr, Frances J; Bradley, Kate J; Helps, Chris R; Cannon, Martha J; Gruffydd-Jones, Timothy J

    2009-12-01

    Polycystic kidney disease (PKD) is the most prevalent inherited genetic disease in cats with Persian and Persian-related breeds predominantly affected. Diagnosis of PKD relied on ultrasound scanning until the recent development of the PKD gene test. However, gene testing has limitations as it will only identify the autosomal dominant form of PKD and not other forms of cystic kidney disease. Ultrasound scanning also has the advantage of being able to assess the severity and progression of disease in PKD affected cats. The aim of this study was to demonstrate the repeatability of ultrasound scanning in the detection of PKD and to assess progression of the disease over time. This study demonstrated 100% repeatability of ultrasound scanning in the detection of PKD and has also demonstrated progression of disease in 75% of PKD positive cats assessed over a 1-year period.

  19. Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

    Science.gov (United States)

    Jezewski, Janusz; Wrobel, Janusz; Matonia, Adam; Horoba, Krzysztof; Martinek, Radek; Kupka, Tomasz; Jezewski, Michal

    2017-01-01

    Great expectations are connected with application of indirect fetal electrocardiography (FECG), especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR) variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US). Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D), long-term variability (LTV), as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV). The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41) and abnormal (19) fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method) enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8%) and particularly deceleration (54%) patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not depend on

  20. Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

    Directory of Open Access Journals (Sweden)

    Janusz Jezewski

    2017-05-01

    Full Text Available Great expectations are connected with application of indirect fetal electrocardiography (FECG, especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US. Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D, long-term variability (LTV, as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV. The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41 and abnormal (19 fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8% and particularly deceleration (54% patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not

  1. Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study.

    Science.gov (United States)

    Kording, Fabian; Yamamura, Jin; Lund, Gunnar; Ueberle, Friedrich; Jung, Caroline; Adam, Gerhard; Schoennagel, Bjoern Philip

    2017-04-10

    Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types. Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry]. Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (p ECG/DUS = 0.4, p ECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different. This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.

  2. Ultrasound propagation in steel piping at electric power plant using clamp-on ultrasonic pulse doppler velocity-profile flowmeter

    International Nuclear Information System (INIS)

    Tezuka, Kenichi; Mori, Michitsugu; Wada, Sanehiro; Aritomi, Masanori; Kikura, Hiroshige

    2008-01-01

    Venturi nozzles are widely used to measure the flow rates of reactor feedwater. This flow rate of nuclear reactor feedwater is an important factor in the operation of nuclear power reactors. Some other types of flowmeters have been proposed to improve measurement accuracy. The ultrasonic pulse Doppler velocity-profile flowmeter is expected to be a candidate method because it can measure the flow profiles across the pipe cross sections. For the accurate estimation of the flow velocity, the incidence angle of ultrasonic entering the fluid should be carefully estimated by the theoretical approach. However, the evaluation of the ultrasound propagation is not straightforward for the several reasons such as temperature gradient in the wedge or mode conversion at the interface between the wedge and pipe. In recent years, the simulation code for ultrasound propagation has come into use in the nuclear field for nondestructive testing. This article analyzes and discusses ultrasound propagation in steel piping and water, using the 3D-FEM simulation code and the Kirchhoff method, as it relates to the flow profile measurements in power plants with the ultrasonic pulse Doppler velocity-profile flowmeter. (author)

  3. 3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

    International Nuclear Information System (INIS)

    Sels, Seppe; Ribbens, Bart; Mertens, Luc; Vanlanduit, Steve

    2016-01-01

    Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical

  4. Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

    International Nuclear Information System (INIS)

    Weekes, B.; Ewins, D.; Acciavatti, F.

    2014-01-01

    To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics

  5. Value of color Doppler ultrasound in diagnosis of portal hypertension liver cirrhosis merged with esophageal variceal bleeding

    Directory of Open Access Journals (Sweden)

    Hai-Rong Yang

    2016-03-01

    Full Text Available Objective: To explore the value of color Doppler ultrasound in the diagnosis of portal hypertension liver cirrhosis merged with esophageal variceal bleeding. Methods: The clinical materials of 30 patients with portal hypertension liver cirrhosis merged with esophageal varices who were admitted in our hospital from August, 2014 to August, 2015 were retrospectively analyzed. According to whether there was a history of hematemesis and melena or not before and 3 months after ultrasound examination, and whether was esophageal variceal bleeding or not confirming by the electronic gastroscopy, the patients were divided into the bleeding group (17 cases and non-bleeding group (13 cases. The color Doppler ultrasonic diagnosis apparatus was used to detect the inner diameter and blood flow rate of splenic vein, portal vein, and left gastric vein. The blood flow volume of splenic vein, portal vein, and left gastric vein was calculated. Results: The inner diameter and blood flow volume of splenic vein in the bleeding group were significantly higher than those in the non-bleeding group, but the blood flow rate was significantly lower than that in the non-bleeding group (P0.05. The inner diameter of left gastric vein in the bleeding group was significantly higher than that in the non-bleeding group, but the blood flow rate was significantly lower that that in the non-bleeding group (P0.05. Conclusions: Color Doppler ultrasound can detect the inner diameter of splenic vein, portal vein, and left gastric vein, and the related hemodynamic indicators, particularly, the inner diameter, blood flow rate, and blood flow volume of splenic vein are effective in predicting the risk of esophageal variceal bleeding.

  6. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Doppler Ultrasound and Magnetic Resonance Imaging Findings of Penile Mondor’s Disease: Case Report and Literature Review

    International Nuclear Information System (INIS)

    Kantarcı, Umut Hasan; Dirik, Alper; Öztürk, Yasemin Erdem; Kiriş, İlker; Duymuş, Mahmut

    2016-01-01

    Penile involvement is a rare, self-limiting, benign genital condition. In Mondor’s disease the underlying pathology is thrombophlebitis of a superficial vein. In this case report, we want to present a rare Penile Mondor’s disease with literature review. While the diagnosis can be based on history, physical examination and Doppler ultrasound, the necessity of both MRI, MR angiography and intracavernosal vasoactive agent administration can be questioned. Both MRI and intravenous vasoactive agent administration may be helpful in suspicious cases for differential diagnosis and to eliminate other etiologies like pelvic mass or thrombosis

  8. Delamination detection by Multi-Level Wavelet Processing of Continuous Scanning Laser Doppler Vibrometry data

    Science.gov (United States)

    Chiariotti, P.; Martarelli, M.; Revel, G. M.

    2017-12-01

    A novel non-destructive testing procedure for delamination detection based on the exploitation of the simultaneous time and spatial sampling provided by Continuous Scanning Laser Doppler Vibrometry (CSLDV) and the feature extraction capability of Multi-Level wavelet-based processing is presented in this paper. The processing procedure consists in a multi-step approach. Once the optimal mother-wavelet is selected as the one maximizing the Energy to Shannon Entropy Ratio criterion among the mother-wavelet space, a pruning operation aiming at identifying the best combination of nodes inside the full-binary tree given by Wavelet Packet Decomposition (WPD) is performed. The pruning algorithm exploits, in double step way, a measure of the randomness of the point pattern distribution on the damage map space with an analysis of the energy concentration of the wavelet coefficients on those nodes provided by the first pruning operation. A combination of the point pattern distributions provided by each node of the ensemble node set from the pruning algorithm allows for setting a Damage Reliability Index associated to the final damage map. The effectiveness of the whole approach is proven on both simulated and real test cases. A sensitivity analysis related to the influence of noise on the CSLDV signal provided to the algorithm is also discussed, showing that the processing developed is robust enough to measurement noise. The method is promising: damages are well identified on different materials and for different damage-structure varieties.

  9. Motion of tympanic membrane in guinea pig otitis media model measured by scanning laser Doppler vibrometry.

    Science.gov (United States)

    Wang, Xuelin; Guan, Xiying; Pineda, Mario; Gan, Rong Z

    2016-09-01

    Otitis media (OM) is an inflammatory or infectious disease of the middle ear. Acute otitis media (AOM) and otitis media with effusion (OME) are the two major types of OM. However, the tympanic membrane (TM) motion differences induced by AOM and OME have not been quantified in animal models in the literature. In this study, the guinea pig AOM and OME models were created by transbullar injection of Streptococcus pneumoniae type 3 and lipopolysaccharide, respectively. To explore the effects of OM on the entire TM vibration, the measurements of full-field TM motions were performed in the AOM, OME and untreated control ears by using scanning laser Doppler vibrometry (SLDV). The results showed that both AOM and OME generally reduced the displacement peak and produced the traveling-wave-like motions at relatively low frequencies. Compared with the normal ear, OME resulted in a significant change of the TM displacement mainly in the inferior portion of the TM, and AOM significantly affected the surface motion across four quadrants. The SLDV measurements provide more insight into sound-induced TM vibration in diseased ears. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Modeling streamflow from coupled airborne laser scanning and acoustic Doppler current profiler data

    Science.gov (United States)

    Norris, Lam; Kean, Jason W.; Lyon, Steve

    2016-01-01

    The rating curve enables the translation of water depth into stream discharge through a reference cross-section. This study investigates coupling national scale airborne laser scanning (ALS) and acoustic Doppler current profiler (ADCP) bathymetric survey data for generating stream rating curves. A digital terrain model was defined from these data and applied in a physically based 1-D hydraulic model to generate rating curves for a regularly monitored location in northern Sweden. Analysis of the ALS data showed that overestimation of the streambank elevation could be adjusted with a root mean square error (RMSE) block adjustment using a higher accuracy manual topographic survey. The results of our study demonstrate that the rating curve generated from the vertically corrected ALS data combined with ADCP data had lower errors (RMSE = 0.79 m3/s) than the empirical rating curve (RMSE = 1.13 m3/s) when compared to streamflow measurements. We consider these findings encouraging as hydrometric agencies can potentially leverage national-scale ALS and ADCP instrumentation to reduce the cost and effort required for maintaining and establishing rating curves at gauging station sites similar to the Röån River.

  11. Wintertime Local Wind Dynamics from Scanning Doppler Lidar and Air Quality in the Arve River Valley

    Directory of Open Access Journals (Sweden)

    Tiphaine Sabatier

    2018-03-01

    Full Text Available Air quality issues are frequent in urbanized valleys, particularly in wintertime when a temperature inversion forms and the air within the valley is stably stratified over several days. In addition to pollutant sources, local winds can have a significant impact on the spatial distribution and temporal evolution of pollutant concentrations. They can be very complex and difficult to represent in numerical weather prediction models, particularly under stable conditions. Better knowledge of these local winds from observations is also a prerequisite to improving air quality prediction capability. This paper analyses local winds during the Passy-2015 field experiment that took place in a section of the Arve river valley, near Chamonix–Mont-Blanc. This location is one of the worst places in France regarding air quality. The wind analysis, which is mainly based on scanning Doppler lidar data sampling a persistent temperature inversion episode, reveals features consistent with the higher pollutant concentrations observed in this section of the valley as well as their spatial heterogeneities. In particular, an elevated down-valley jet is observed at night in the northern half of the valley, which, combined with a weak daytime up-valley wind, leads to very poor ventilation of the lowest layers. A northeast–southwest gradient in ventilation is observed on a daily-average, and is consistent with the PM10 heterogeneities observed within the valley.

  12. Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access

    International Nuclear Information System (INIS)

    Pietura, Radoslaw; Janczarek, Marzena; Zaluska, Wojciech; Szymanska, Anna; Janicka, Lucyna; Skublewska-Bednarek, Anna; Szczerbo-Trojanowska, Malgorzata

    2005-01-01

    Background: A well-functioning mature arteriovenous fistula is essential for the maintenance of haemodialysis in patients with chronic renal failure. The Brescia-Cimino arteriovenous fistula has the best survival characteristics and low rate of complications. The most common reason of fistula failure is thrombosis caused by stenosis. Colour Doppler ultrasonography has proven to be effective in the assessment of anatomical vascular features. The majority of studies were done in patients with clinically presumed arteriovenous fistula complications. However, only limited data are available about the well-functioning mature arteriovenous fistulas. The purpose of the present study was to evaluate completely asymptomatic, mature arteriovenous fistulas with colour Doppler ultrasound. Materials and methods: From July 2001 to April 2003, we examined 139 patients with the end-stage renal disease. They were in the range of 19-79 years of age (mean, 46.7 years). The study included only the patients who met the following criteria: (1) no difficulties with haemodialysis (as reported by nurses); (2) normal venous diastolic blood pressure (<150 mmHg) at monthly evaluation; (3) normal urea clearance x time/urea volume of distribution; (4) blood cells count, plasma electrolytes, and liver function at monthly evaluation. The mean fistula age was 26 months (S.D. = 21.9). The mean time of dialysis therapy was 49 months. Thirty-eight percent patients had primary fistulas, 23%-secondary, 11%-third and 11%-fourth, 4%-fifth, 5%-sixth, and 8% patients had more than sixth. Results: There was no correlation between: (1) patient's age and fistula age; (2) patient's age and number of fistulas in one patient; (3) fistula age and number of fistulas in one patient; (4) localization of fistula and fistula age. There was a strong correlation between dialysis therapy period and number of fistulas in one patient. The mean flow volume was 1204.1 ml/min (S.D. = 554). It was significantly higher in the

  13. Automated assessment of joint synovitis activity from medical ultrasound and power doppler examinations using image processing and machine learning methods

    Directory of Open Access Journals (Sweden)

    Rafal Cupek

    2016-11-01

    Full Text Available Objectives : Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. Material and methods : This paper focus on a computer aided diagnostic system that was developed within joint Polish–Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner’s experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. Results : The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Conclusions : Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner’s experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an

  14. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  15. Endoscopic ultrasound duplex scanning for measurement of portal venous flow. Validation against transit time ultrasound flowmetry in pigs

    DEFF Research Database (Denmark)

    Hansen, E F; Strandberg, C; Bendtsen, F

    1999-01-01

    with that of transit time ultrasound (TTU) in healthy pigs. The ability of EUS to detect changes in the portal venous flow after pharmacologic intervention was also investigated. METHODS: Six anaesthetized pigs were studied. Portal venous flow was measured simultaneously by EUS duplex scanning, using a Pentax FG-32UA...... echoendoscope connected to a Hitachi EUB 515-A ultrasound scanner, and by TTU with a Cardiomed CM 4000 flowmeter probe placed on the portal vein. Terlipressin, 1 mg, and placebo were administered in a blind, randomized, crossover design. Measurements were taken at base line and 30 min after each drug...

  16. Human abdomen recognition using camera and force sensor in medical robot system for automatic ultrasound scan.

    Science.gov (United States)

    Bin Mustafa, Ammar Safwan; Ishii, Takashi; Matsunaga, Yoshiki; Nakadate, Ryu; Ishii, Hiroyuki; Ogawa, Kouji; Saito, Akiko; Sugawara, Motoaki; Niki, Kiyomi; Takanishi, Atsuo

    2013-01-01

    Physicians use ultrasound scans to obtain real-time images of internal organs, because such scans are safe and inexpensive. However, people in remote areas face difficulties to be scanned due to aging society and physician's shortage. Hence, it is important to develop an autonomous robotic system to perform remote ultrasound scans. Previously, we developed a robotic system for automatic ultrasound scan focusing on human's liver. In order to make it a completely autonomous system, we present in this paper a way to autonomously localize the epigastric region as the starting position for the automatic ultrasound scan. An image processing algorithm marks the umbilicus and mammary papillae on a digital photograph of the patient's abdomen. Then, we made estimation for the location of the epigastric region using the distances between these landmarks. A supporting algorithm distinguishes rib position from epigastrium using the relationship between force and displacement. We implemented these algorithms with the automatic scanning system into an apparatus: a Mitsubishi Electric's MELFA RV-1 six axis manipulator. Tests on 14 healthy male subjects showed the apparatus located the epigastric region with a success rate of 94%. The results suggest that image recognition was effective in localizing a human body part.

  17. Doppler ultrasound surveillance in deep tunneling compressed-air work with Trimix breathing: bounce dive technique compared to saturation-excursion technique.

    Science.gov (United States)

    Vellinga, T P van Rees; Sterk, W; de Boer, A G E M; van der Beek, A J; Verhoeven, A C; van Dijk, F J H

    2008-01-01

    The Western Scheldt Tunneling Project in The Netherlands provided a unique opportunity to evaluate two deep-diving techniques with Doppler ultrasound surveillance. Divers used the bounce diving techniques for repair and maintenance of the TBM. The tunnel boring machine jammed at its deepest depth. As a result the work time was not sufficient. The saturation diving technique was developed and permitted longer work time at great depth. Thirty-one divers were involved in this project. Twenty-three divers were examined using Doppler ultrasound. Data analysis addressed 52 exposures to Trimix at 4.6-4.8 bar gauge using the bounce technique and 354 exposures to Trimix at 4.0-6.9 bar gauge on saturation excursions. No decompression incidents occurred with either technique during the described phase of the project. Doppler ultrasound revealed that the bubble loads assessed in both techniques were generally low. We find out, that despite longer working hours, shorter decompression times and larger physical workloads, the saturation-excursion technique was associated with significant lower bubble grades than in the bounce technique using Doppler Ultrasound. We conclude that the saturation-excursion technique with Trimix is a good option for deep and long exposures in caisson work. The Doppler technique proved valuable, and it should be incorporated in future compressed-air work.

  18. Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths

    DEFF Research Database (Denmark)

    Ammitzboll-Danielsen, Mads; Janta, Iustina; Torp-Pedersen, Søren

    2016-01-01

    interpretation of Doppler signals when diagnosing tenosynovitis. Method Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger...... participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). Conclusion Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers...

  19. Ultrasound elastography improves differentiation between benign and malignant breast lumps using B-mode ultrasound and color Doppler

    Directory of Open Access Journals (Sweden)

    Amany Elkharbotly

    2015-12-01

    Conclusion: Combined use of B-mode US, UE and color Doppler achieved NPV of 95% thus allowed sparing of unnecessary invasive diagnostic procedures. UE as a sole diagnostic test has high sensitivity and specificity. Mammography could be used as screening test for its high sensitivity.

  20. Thrombolytic therapy with rt-PA and transcranial color Doppler ultrasound (TCCS) combined with microbubbles for embolic thrombus.

    Science.gov (United States)

    Ren, Xinping; Wang, Yong; Wang, Yi; Chen, Hong; Chen, Li; Liu, Yi; Xue, Chengshi

    2015-11-01

    To investigate the efficacy of transcranial color Doppler ultrasound (TCCS) combined with microbubbles (MBs) and rt-PA (recombinant tissue plasminogen activator) for thrombolysis in vivo. An arterial embolization model was established in Sprague-Dawley rats by retrograde placement of autologous thrombi into the common carotid artery followed by ligation of external carotid artery and temporary occlusion of the carotid artery and internal carotid artery by clamping. The animals were divided into 5 groups with 6 rats in each group: ① untreated control group, ② rt-PA group, ③ TCCS+MBs group, ④ TCCS+MBs+rt-PA group, ⑤ TCCS+MBs+1/2 rt-PA+group. Thrombolytic effects including recanalization rate and recanalization grade were evaluated with grayscale and color Doppler ultrasound post treatment. Examination of histological change in the involved vessel was performed at the end of the experiments. Thrombolysis in terms of recanalization rate and recanalization grade was observed in the treated groups in a time-dependent manner, except the TCCS+MBs group. Addition of rt-PA remarkably enhanced the therapeutic lysis in TCCS+MBs group. However, no difference of therapeutic effects existed between TCCS+MBs+rt-PA group and TCCS+MBs+1/2 rt-PA group. TCCS+MBs combined with rt-PA is a relatively effective approach for ischemic arterial thrombosis with an additive or synergistic effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Monitoring cerebral hemodynamics with transcranial Doppler ultrasound during cognitive and exercise testing in adults following unilateral stroke.

    Science.gov (United States)

    Watt, Brian P; Burnfield, Judith M; Truemper, Edward J; Buster, Thad W; Bashford, Gregory R

    2012-01-01

    An observational study was performed as a preliminary investigation into the use of transcranial Doppler ultrasound (TCD) for recording cerebral hemodynamic changes during multiple tasks. TCD is a method of measuring cerebral blood flow (CBF) using ultrasound transducers in contact with the surface of the head. Using the maximum flow envelope of the Doppler spectrum returning from the middle cerebral artery (MCA), standard clinical flow indices can be calculated and displayed in real time providing information concerning perturbations in CBF and their potential cause. These indices as well as flow velocity measurements have been recognized as useful in measuring changes in responses to various stimulus that can be used to indicate cardiovascular health. For this study, the pulsatility index (PI) and resistivity index (RI) were chosen since they indicate composite changes indicative of vasoconstriction and vasodilatation which are normal hemodynamic responses under appropriate conditions. A total of eleven participants were recruited to take part in this study. Nine of these individuals had no known disability (Controls); two had experienced unilateral cerebrovascular accidents (Strokes) in the ipsilateral MCA distribution. Maximum velocity envelopes of the spectral Doppler data were recorded using a fixation device designed to stabilize two ultrasound probes (2 MHz) to sample the bilateral MCAs CBF. These measures were performed separately while the subject performed four activities: 1) rest, 2) cognitive challenge, 3) cardiovascular exercise, and 4) simultaneous exercise and cognitive challenge. Cardiovascular parameters were calculated from the data by extracting maximum (Vs) and minimum flow velocities (Vd), PI, RI, and time signatures for each cardiac cycle. The data for all participants shows significant changes in cardiovascular parameters between states of rest and exercise, as well as slight trends across time. Although the data are preliminary, they show

  2. Role of ultrasound scanning in community contraceptive and reproductive health clinics.

    Science.gov (United States)

    Brockmeyer, Andrea; Webb, Anne

    2008-04-01

    The role of ultrasound scanning (USS) in the community setting of contraception and reproductive health (CRH) has not yet been clearly established. Abacus Clinics use ultrasound scans prior to referral for abortion where gestation is uncertain and for location of an intrauterine device/intrauterine system (IUD/IUS). To audit the indications for USS performed in Abacus Clinics and to determine a minimum acceptable number of annual scans for each clinician. A retrospective review of case notes was performed for a period of 3 months. The majority of women (36; 64%) had a scan to determine gestation prior to referral for abortion. In 12 (21%) women the scan was performed for location of an IUD/IUS. Two (4%) women had a scan for both indications. Only six (11%) women did not comply with the indications listed above but all were related to gestation or IUD/IUS use. In 16 women the scan significantly influenced decision-making regarding referral to the appropriate abortion service provider. The number of scans performed by individual doctors varied between two and 12. The use of USS prevented unnecessary referrals to hospital and delays in clients' care. The number of scans each clinician performed was small and the indications for future USS were only slightly changed. The new special skills module in ultrasound developed by the Faculty of Sexual and Reproductive Healthcare(FSRH) (formerly the Faculty of Family Planning and Reproductive Health Care) aims to set new standards and should improve training.

  3. Power Doppler ultrasound of breast cancer: Correlation with histologic microvessel density and lymph node metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Lee, Yong Hee; Son, Hong Ju; Oh, Ki Keun; Chung, Hyun Cheol; Lee, Kyong Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate how breast cancer vascularity detected by power Doppler sonography correlates with microvessel density(MVD) and lymph node involvement. Power Doppler US was performed on 47 patients with pathologically diagnosed invasive ductal carcinoma. According to the presense or absence of vessels, power Doppler findings were categorized regarding total tumors and tumors less than 2 cm. MVD was assessed immunohistochemically using polyclonal antisera against factor VIII. Tumor vascularity was correlated with MVD and lymph node involvement. Among 47 infiltrating ductal carcinomas, 35 (74.5%) cases were vascular and 12 (25.5%) cases were avascular on power Doppler US. The mean MVD of the vascular and avascular carcinomas did not show any statistical difference. However, lymph mode involvement showed significant statistical difference between the two groups (51.4% versus 25.0%, p=0.036), even though in cancers less than 2 cm (40% versus 22.2%, p=0.047). Breast cancer vascularity detected by power Doppler sonography was not correlated with MVD but correlated with lymph node involvement. So we suggest that power Doppler sonography may be useful for predicting lymph node metastasis.

  4. The development of a combined b-mode, ARFI, and spectral Doppler ultrasound imaging system for investigating cardiovascular stiffness and hemodynamics

    Science.gov (United States)

    Doherty, Joshua R.; Dumont, Douglas M.; Trahey, Gregg E.

    2011-03-01

    The progression of atherosclerotic disease, caused by the formation of plaques within arteries, is a complex process believed to be a function of the localized mechanical properties and hemodynamic loading associated with the arterial wall. It is hypothesized that measurements of vascular stiffness and wall-shear rate (WSR) may provide important information regarding vascular remodeling, endothelial function, and the growth of soft-lipid filled plaques that could help a clinician better diagnose a patient's risk of clinical events such as stroke. To that end, the approach taken in this work was to combine conventional B-mode, Acoustic Radiation Force Impulse (ARFI), Shear Wave Elasticity Imaging (SWEI), and spectral Doppler techniques into a single imaging system capable of simultaneously measuring the tissue displacements and WSR throughout the cardiac cycle and over several heartbeats. Implemented on a conventional scanner, the carotid arteries of human subjects were scanned to demonstrate the initial in vivo feasibility of the method. Two non-invasive ultrasound based imaging methods, SAD-SWEI and SAD-Gated Imaging, were developed that measure ARF-induced on-axis tissue displacements, off-axis transverse wave velocities, and WSR throughout the cardiac cycle. Human carotid artery scans were performed in vivo on 5 healthy subjects. Statistical differences were observed in both on-axis proximal wall displacements and transverse wave velocities during diastole compared to systole.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  6. Diagnostic significance of ultrasound in dermatology

    OpenAIRE

    Stojanović Slobodan; Poljački Mirjana N.; Roš Tatjana

    2002-01-01

    Introduction Utilization of 20 MHz ultrasound probes provided application of ultrasound in dermatology - dermatosonography. As a diagnostic tool, ultrasound was first registered in the early fifties of the past century. Great progress of dermatosonography occurred in the mid-nineties with introduction of the first 20 MHz scanner. Methods of ultrasonography in dermatology Several methods of ultrasonography have been developed: method A, method B, scanning C method and Doppler ultrasound. They ...

  7. Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

    Science.gov (United States)

    Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A

    2009-06-01

    The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler. 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%). Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester. (c) 2009 ISUOG.

  8. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  9. A STUDY ON ROLE OF DOPPLER ULTRASOUND IN NORMAL AND HIGH-RISK PREGNANCIES WITH PERINATAL OUTCOME

    Directory of Open Access Journals (Sweden)

    Mozibur Rahman Laskar

    2016-09-01

    Full Text Available OBJECTIVES To evaluate the diagnostic value of various waveform of Doppler ultrasound of three vessels (uterine artery, middle cerebral artery and umbilical artery in high-risk pregnancies in compare to normal pregnancy related to perinatal outcome. MATERIALS AND METHODS 200 singleton pregnancies beyond 28 weeks of gestation were studied out of which 100 were normal and 100 were high-risk pregnancies with PIH and clinical suspicion of IUGR. Doppler examination was done after recording history, clinical ex and USG. RESULTS The PI, RI and S/D of Umbilical artery and Uterine artery were significantly higher in study group as compared to control group and the PI, RI and S/D of middle cerebral artery were significantly lower in study group as compared to control group. 70% of foetuses in study group had at least one adverse outcome in study group in contrast to only 10% of control group had adverse outcome. Doppler study of UA and UmbA together had a better sensitivity than individual vessel. The MCA/UmbA PI ratio of study group showed more foetuses to redistribute their cardiac output than the abnormal MCA PI or UmbA PI. The cerebroumbilical ratio provided a better predictor of high-risk pregnancies and adverse perinatal outcome than either MCA or UmbA. CONCLUSION Hence, we conclude that Doppler studies of multiple vessels in the foetoplacental circulation can help in the monitoring of compromised foetus and can help in predicting neonatal morbidity. This may be helpful in determining the optimal time of delivery in complicated pregnancies. ABBREVIATIONS UA-Uterine artery, UmbA-Umbilical artery, MCA-Middle cerebral artery, RI-Resistive index, PI-Pulsatility index, S/DSystolic/Diastolic ratio, IUGR-Intrauterine growth restriction, IUFD-Intrauterine fetal demise, LSCS-Lower segment caesarean section, SVD-Spontaneous vaginal delivery, PIH- Pregnancy-induced hypertension.

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... at home and wear loose, comfortable clothing. You may be asked to wear a gown. What is ... into 3-D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , ...

  11. Doppler ultrasound and magnetic resonance for evaluation of patients treated surgically for aortic coarctation. Ecografia Doppler y resonancia magnetica en la evaluacion de pacientes con coartacion de aorta operada

    Energy Technology Data Exchange (ETDEWEB)

    Canteli, B.; Saez, F.; Garcia, F.; Cabrera, A.; Galdeano, J.M.; Rodriguez, O. (Hospital de Cruzes, Vizcaya (Spain))

    1994-01-01

    Doppler ultrasound and magnetic resonance were performed in a series of 39 patients who had been treated surgically for aortic coarctation. The purpose was to assess the different Doppler gradients, comparing the findings with morphological data disclosed by magnetic resonance. The aortic caliber in the operative field was pathological in 7 patients (ratio between the caliber at the level of the lesion and that of descending aorta of less than 0.7). When the patients were considered as a group. Doppler ultrasound did not show satisfactory sensitivity (29%-43%), specificity (74%) or positive predictive value (17%-23%). Only the negative predictive value (85%-88%) presented more favorable results. When the Subgroup of patients without associated cardiac abnormalities or collateral circulation was studied alone, the following results were found: sensitivity, 100%; specificity, 81%-90%, positive predictive value, 33%-50%, negative predictive value, 100%, similar to those reported in the literature. Thus, we consider that Doppler ultrasound is a harmless and low cost diagnostic method that is highly suitable for follow-up of these patients, within certain limits. Magnetic resonance is the method of choice for the noninvasive assessment of aortic morphology. (Author)

  12. Estudo da macrovasculatura por ultra-sonografia Doppler na esclerose sistêmica Study of macrovasculature by Doppler ultrasound in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Emmanuelle Tenório Albuquerque Madruga Godoi

    2008-04-01

    Full Text Available OBJETIVO: Avaliar a ocorrência e a distribuição das alterações macrovasculares em uma população com esclerose sistêmica (ES por meio da ultra-sonografia Doppler (USG Doppler e do índice tornozelo-braço (ITB. Foi investigada a associação destes achados com as características demográficas e clínicas dos pacientes, bem como fatores de risco e antecedentes da doença ateromatosa. MÉTODOS: Estudo prospectivo, tipo série de casos, constituído de 20 pacientes, sendo 19 do sexo feminino, com idade média de 46,30 anos. A forma clínica difusa esteve presente em 85% dos pacientes. Todos tinham fenômeno de Raynaud (FR, 55% apresentaram alteração de polpas digitais, 15% úlcera atual de membros e 25% reabsorção de falange. Não houve amputação e 70% apresentaram de um a quatro fatores de risco de aterosclerose. A aorta, as carótidas, bem como as artérias dos membros superiores (MMSS e inferiores (MMII foram estudadas por USG Doppler para a avaliação de espessamento do complexo íntima-medial (CIM, presença de placas e aneurismas. Nas artérias dos MMII, foi também realizado o ITB. RESULTADOS: O ITB foi normal em todos os pacientes, entretanto 12 (60% destes apresentaram doença macrovascular (DMV, sendo 9 (45% na aorta, 7 (35% nos MMII, 6 (30% nas carótidas e 1 (5% nas artérias dos MMSS. Observou-se associação entre DMV e alterações de polpas digitais (p = 0,0045. CONCLUSÕES: A USG Doppler identificou DMV em 60% dos pacientes com ES. Nenhum paciente apresentou ITB anormal. Verificou-se associação significante da DMV com as alterações atuais de polpas digitais. As alterações macrovasculares encontradas não estão necessariamente associadas à esclerose sistêmica e podem decorrer do processo aterosclerótico.OBJECTIVE: To assess the occurrence and distribution of the macrovascular alterations in a population with Systemic Sclerosis (SS by means of Doppler ultrasound (Doppler US and ankle-arm index (AAI. To

  13. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  14. Doppler ultrasound surveillance in deep tunneling compressed-air work with Trimix breathing: bounce dive technique compared to saturation-excursion technique

    NARCIS (Netherlands)

    Vellinga, T. P. Van Rees; Sterk, W.; de Boer, A. G. E. M.; van der Beek, A. J.; Verhoeven, A. C.; van Dijk, F. J. H.

    2008-01-01

    The Western Scheldt Tunneling Project in The Netherlands provided a unique opportunity to evaluate two deep-diving techniques with Doppler ultrasound surveillance. Divers used the bounce diving techniques for repair and maintenance of the TBM. The tunnel boring machine jammed at its deepest depth.

  15. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta

    Directory of Open Access Journals (Sweden)

    Elham Naghshineh

    2015-01-01

    Conclusions: Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.

  16. Quantitative Doppler ultrasound evaluation of occlusive arterial disease in the lower limb

    DEFF Research Database (Denmark)

    Bagi, P; Sillesen, H; Hansen, H J

    1988-01-01

    Forty consecutive patients with lower limb arterial disease were evaluated using a multi-gated pulsed Doppler system. Doppler signals were sampled at 4 sites in each limb, and following spectral analysis, the pulse rise time (PRT) was measured. The value obtained at the location giving the longest...... duration of PRT was used for comparison with ankle/brachial pressure index (A/B index) and angiography. A highly significant correlation was found between PRT and A/B index (r = -0.75, P less than 0.001). Based on receiver operating characteristic curves an overall diagnostic accuracy of 90% in diagnosing...

  17. Two-dimensional power Doppler-three-dimensional ultrasound imaging of a cesarean section dehiscence with utero-peritoneal fistula: a case report

    Directory of Open Access Journals (Sweden)

    Royo Pedro

    2009-01-01

    Full Text Available Abstract Introduction An imaging diagnosis after an iterative cesarean delivery is reviewed demonstrating a fine ultrasound-pathologic correlation. Case presentation A 33-year-old woman (G3, P3 presented referring intense dysmenorrhea and intermenstrual spotting since her third cesarean delivery, 1 year before. A cesarean section dehiscence with utero-peritoneal fistula was diagnosed by transvaginal ultrasound. Conclusion We can conclude that transvaginal two-dimensional power Doppler and three-dimensional ultrasound are highly accurate in detecting cesarean section dehiscence and uterine fistula.

  18. Estimation of pulses in ultrasound B-scan images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1991-01-01

    It is shown, based on an expression for the received pressure field in pulsed medical ultrasound systems, that a common one-dimensional pulse can be estimated from individual A-lines. An autoregressive moving average (ARMA) model is suggested for the pulse, and an estimator based on the prediction...... error method is derived. The estimator is used on a segment of an A-line, assuming that the pulse does not change significantly inside the segment. Several examples of the use of the estimator on synthetic data measured from a tissue phantom and in vitro data measured from a calf's liver are given....... They show that a pulse can be estimated even at moderate signal-to-noise ratios...

  19. Doppler ultrasound evaluation of pattern of venous incompetance and relation with skin changes in varicose vein patients

    Directory of Open Access Journals (Sweden)

    HP Pant

    2015-06-01

    Full Text Available BACKGROUND Varicosity of lower limb is a common problem in agricultural country like Nepal. Doppler ultrasound is a standard investigation modality for confirmation of diagnosis, evaluation of severity and venous mapping to plan treatment. We aim to find out the epidemiology, common pattern of incompetance, severity assessment by doppler and association of the important doppler variables with skin changes. METHODOLOGY Doppler venous study was done in 56 patients from june 2013 to july 2014. Patients with deep vein thrombosis and peripheral arterial disease were excluded. Altogether 56 patients, 96 limbs were studied. Data was entered in preformed proforma. Doppler study was conducted by senior radiologist with linear probes. Data was entered in SPSS software version 16 and statistical significance was calculated using chi square test. RESULTS Bilateral limb involvement was seen in 40 patients and unilateral in 16 patuents only. Skin related changes were seen in 58 limbs. Saphenofemoral junction incompetance was seen in 79(82.2% limbs and was most common pattern of incompetance. Overall, superficial veins were involved in 88(91.7% limbs and deep in 30(31.2% limbs. Prolonged duration of varicosity (>9 year (p=0.000, bilateral limb involvement(p=0.024, reflux in deep venous system(p=0.002, larger Greater Saphenous Vein (GSV size(p=0.003, prolonged duration of reflux(p=0.000 and perforator incompetence (p=0.002 were associated with skin changes. GSV diameter more than 7 mm was associated with reflux significantly (P=0.002. CONCLUSION Superficial vein incompetance is common pattern compared to deep venous system. Sapheno Femoral Junction (SFJ incompetance is the commonest pattern. Larger caliber of vein, prolonged duration of reflux, reflux in deep venous system and perforator insufficiency are significantly associated with skin changes.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12770 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3

  20. CALF BLOOD-FLOW AND POSTURE - DOPPLER ULTRASOUND MEASUREMENTS DURING AND AFTER EXERCISE

    NARCIS (Netherlands)

    VANLEEUWEN, BE; BARENDSEN, GJ; LUBBERS, J; DEPATER, L

    To investigate the joint effects of body posture and calf muscle pump, the calf blood flow of eight healthy volunteers was measured with pulsed Doppler equipment during and after 3 min of rhythmic exercise on a calf ergometer in the supine, sitting, and standing postures. Muscle contractions

  1. Ultrasound Doppler but not temporal summation of pain predicts DAS28 response in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Christensen, Anton Wulf; Rifbjerg-Madsen, Signe; Christensen, Robin

    2016-01-01

    OBJECTIVE: Previous studies have suggested a link between inflammation and central sensitization of pain in patients with RA. We conducted a prospective cohort study to determine whether US Doppler (USD), temporal summation (TS) of pain-assessed at baseline-and the potential interaction between...

  2. Analysis of ultrasound propagation in high-temperature nuclear reactor feedwater to investigate a clamp-on ultrasonic pulse doppler flowmeter

    International Nuclear Information System (INIS)

    Tezuka, Kenichi; Mori, Michitsugu; Wada, Sanehiro; Aritomi, Masanori; Kikura, Hiroshige; Sakai, Yukihiro

    2008-01-01

    The flow rate of nuclear reactor feedwater is an important factor in the operation of a nuclear power reactor. Venturi nozzles are widely used to measure the flow rate. Other types of flowmeters have been proposed to improve measurement accuracy and permit the flow rate and reactor power to be increased. The ultrasonic pulse Doppler system is expected to be a candidate method because it can measure the flow profile across the pipe cross section, which changes with time. For accurate estimation of the flow velocity, the incidence angle of ultrasound entering the fluid should be estimated using Snell's law. However, evaluation of the ultrasound propagation is not straightforward, especially for a high-temperature pipe with a clamp-on ultrasonic Doppler flowmeter. The ultrasound beam path may differ from what is expected from Snell's law due to the temperature gradient in the wedge and variation in the acoustic impedance between interfaces. Recently, simulation code for ultrasound propagation has come into use in the nuclear field for nondestructive testing. This article analyzes and discusses ultrasound propagation, using 3D-FEM simulation code plus the Kirchhoff method, as it relates to flow profile measurement in nuclear reactor feedwater with the ultrasonic pulse Doppler system. (author)

  3. Effects of Hot Packs on Small-Intestinal Motility Measured by Doppler Ultrasound and Subjective Feelings in Normal Adults.

    Science.gov (United States)

    Makino, Yusuke; Choe, Myoung-Ae

    Constipation is a common problem in patients and the general population. Hot packs can relieve constipation, but the effect on small-intestinal motility remains unknown. We aimed to determine the effect of hot packs on small-intestinal motility and subjective feelings associated with bowel activity after removing the hot packs. Thirty-four normal adults were assigned to either an experimental group (n = 18) or a control group (n = 16). Hot and normal packs were applied for 10 minutes to the lumbar regions of the experimental and control groups, respectively. Small-intestinal motility was measured by Doppler ultrasound before, during, and after pack application. Subjective feelings were also evaluated after removing the packs. The number of small-intestinal peristalses and subjective feelings of 20 participants showing anechoic areas in the small-intestinal lumen were analyzed.

  4. Wideband Doppler Ultrasound-guided Mini-endoscopic Combined Intrarenal Surgery as an Effective and Safe Procedure for Management of Large Renal Stones: A Preliminary Report.

    Science.gov (United States)

    Inoue, Takaaki; Kinoshita, Hidefumi; Okada, Shinsuke; Hamamoto, Shuzo; Taguchi, Makoto; Murota, Takashi; Matsuda, Tadashi

    2016-09-01

    To evaluate the efficacy and safety of wideband Doppler ultrasound-guided mini-endoscopic combined intrarenal surgery (mini-ECIRS) for large renal stones. This study included 41 patients with large renal stones (>30 mm) treated by mini-ECIRS using a retrograde flexible ureteroscope and miniature nephroscope by wideband Doppler ultrasound guidance in the modified Valdivia position from January 2013 to September 2015. Surgical parameters, including the stone-free rate, operative time, complications (especially hemorrhagic complications), and hemoglobin drop were recorded and analyzed. Univariate analysis was performed to identify risk factors for a hemoglobin drop of ≥1 g/dL. The mean stone size, including staghorn calculi in 41.4% of cases, was 45.5 ± 14.7 mm. Percutaneous access into the calices using wideband Doppler ultrasound was successful in all cases. The mean total operative time was 158.4 ± 51.3 minutes. The mean mini-ECIRS time (from first percutaneous puncture to end of procedure) was 106.2 ± 36.0 minutes. The initial stone-free rate was 73.2% (n = 30). The final stone-free rate after auxiliary treatment was 97.5% (n = 40). The mean hemoglobin drop was 0.54 ± 0.65 g/dL. Three (7.3%) postoperative modified Clavien grade II complications occurred. Univariate analysis revealed no significant risk factors for a hemoglobin drop of ≥1 g/dL. Wideband Doppler ultrasound-guided renal puncture is safe and feasible. Wideband Doppler ultrasound-guided mini-ECIRS is a beneficial, versatile, and safe treatment option for management of large renal stones of >30 mm. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Evaluation of the relationship between renal function and renal volume-vascular indices using 3D power Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cansu, Aysegul, E-mail: drcansu@gmail.com; Kupeli, Ali; Kul, Sibel; Eyuboglu, Ilker; Oguz, Sukru; Ozturk, Mehmet Halil; Dinc, Hasan

    2014-07-15

    Purpose: To investigate the relationship between renal function and total renal volume-vascular indices using 3D power Doppler ultrasound (3DPDUS). Materials and methods: One hundred six patients with hypertensive proteinuric nephropathy (HPN) (49 male, 57 female) and 65 healthy controls (32 male, 33 female) were evaluated prospectively using 3DPDUS. Total renal volume (RV), vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were calculated using Virtual Organ Computer-aided Analysis (VOCAL). The estimated glomerular filtration rates (GFRs) of the patients with HPN and the control group were calculated. The patients with HPN were divided into two groups on the basis of GFR, normal (≥90) or reduced (<90). Differences between groups were compared using ANOVA. Correlations between GFR, renal volume and vascular indices were analyzed using Pearson's correlation analysis. Significance was set at p < 0.05. Results: The mean total RV, VI, FI and VFI values in the reduced GFR, normal GFR and control groups were RV (ml): 234.7, 280.7 and 294.6; VI: 17.6, 27.6 and 46.8; FI: 79.1, 88.7 and 93.9 and VFI: 7.1, 12.7 and 23.8. There were statistically significant differences between the groups (p < 0.001). Total RVs and vascular indices exhibited significant correlations with estimated GFR (r = 0.53–0.59, p < 0.001) Conclusion: Three-dimensional power Doppler ultrasound is a reliable predictive technique in renal function analysis.

  6. Doppler scans of lower limbs' DVT: experience at University of Benin ...

    African Journals Online (AJOL)

    Background: Deep Vein Thrombosis (DVT) result from coagulation of blood in the deep veins and can also lead to leg swelling and gangrene. It is a potentially lethal disorder that can lead to pulmonary embolism with resultant high mortality rate. Objectives: To document the pattern of DVT, our experiences at DVT Doppler ...

  7. Power Doppler Ultrasound Evaluation of Peripheral Joint, Entheses, Tendon, and Bursa Abnormalities in Psoriatic Patients: A Clinical Study.

    Science.gov (United States)

    Tang, Yuanjiao; Yang, Yujia; Xiang, Xi; Wang, Liyun; Zhang, Lingyan; Qiu, Li

    2018-04-15

    To evaluate the prevalence rates of peripheral joint, enthesis, tendon, and bursa abnormalities by power Doppler (PD) ultrasonic examination in patients with psoriatic arthritis (PsA), psoriatic patients without clinical signs of arthritis (non-PsA psoriasis group), and healthy individuals, to detect subclinical PsA. A total of 253 healthy volunteers, 242 non-PsA psoriatic patients, and 86 patients with PsA were assessed by 2-dimensional and power Doppler (PD) ultrasound. Peripheral joint, enthesis, tendon, and bursa abnormalities were observed, characterizing abnormal PD. The affected patients and sites with abnormalities in various ages were compared among groups; PD signal grades for the abnormalities were also compared. In the PsA group, significantly higher percentages of sites showing joint effusion/synovitis, enthesitis, and tenosynovitis in all age groups, and markedly higher rates of sites with bursitis were found in young and middle age groups, compared with the non-PsA and control groups (all p the non-PsA group showed significantly higher rates of joint effusion/synovitis and enthesitis sites, and elevated PD signal grades of synovitis, enthesitis, and tenosynovitis in comparison with the control group, both in young and middle age groups (all p tenosynovitis.

  8. A multi-dimensional approach for describing internal bleeding in an artery: implications for Doppler ultrasound guiding HIFU hemostasis

    Science.gov (United States)

    Yang, Di; Zhang, Dong; Guo, Xiasheng; Gong, Xiufen; Fei, Xingbo

    2008-09-01

    Doppler ultrasound has shown promise in detecting and localizing internal bleeding. A mathematical approach was developed to describe the internal bleeding of the injured artery surrounded by tissue. This approach consisted of a two-dimensional (2D) model describing the injured vessel and a one-dimensional model (1D) mimicking the downstream of the vessel system. The validity of this approach was confirmed by both the numerical simulation and in vivo measurement of a normal porcine femoral artery. Furthermore, the artery was injured using a 16-gauge needle to model a penetrating injury. The velocity waveform at the puncture site was modeled and compared with those at the upstream and downstream of the artery. The results demonstrated that there was a significant increase in magnitude and a phase lag for the peak systolic velocity at the injury site. These results were qualitatively in agreement with the in vivo experiment. Flow turbulence indicated by this approach was also observed in a color Doppler image in the form of a checkered color pattern. This approach might be useful for quantitative internal bleeding detection and localization. Also, the phase lag of the peak systolic velocity was indicated to be potential in the application of internal bleeding detection.

  9. A multi-dimensional approach for describing internal bleeding in an artery: implications for Doppler ultrasound guiding HIFU hemostasis

    Energy Technology Data Exchange (ETDEWEB)

    Yang Di; Zhang Dong; Guo Xiasheng; Gong Xiufen [Institute of Acoustics, Key Laboratory of Modern Acoustics (Nanjing University), Ministry of Education, Nanjing University, Nanjing 210093 (China); Fei Xingbo [Beijing Yuande Biomedical Company, Beijing 100176 (China)], E-mail: dzhang@nju.edu.cn

    2008-09-21

    Doppler ultrasound has shown promise in detecting and localizing internal bleeding. A mathematical approach was developed to describe the internal bleeding of the injured artery surrounded by tissue. This approach consisted of a two-dimensional (2D) model describing the injured vessel and a one-dimensional model (1D) mimicking the downstream of the vessel system. The validity of this approach was confirmed by both the numerical simulation and in vivo measurement of a normal porcine femoral artery. Furthermore, the artery was injured using a 16-gauge needle to model a penetrating injury. The velocity waveform at the puncture site was modeled and compared with those at the upstream and downstream of the artery. The results demonstrated that there was a significant increase in magnitude and a phase lag for the peak systolic velocity at the injury site. These results were qualitatively in agreement with the in vivo experiment. Flow turbulence indicated by this approach was also observed in a color Doppler image in the form of a checkered color pattern. This approach might be useful for quantitative internal bleeding detection and localization. Also, the phase lag of the peak systolic velocity was indicated to be potential in the application of internal bleeding detection.

  10. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  11. Spontaneous interstitial pregnancy on a tubal stump after unilateral adenectomy followed by transvaginal colour Doppler ultrasound.

    Science.gov (United States)

    Bernardini, L; Valenzano, M; Foglia, G

    1998-06-01

    Transvaginal colour and angio Doppler blood flow analysis combined with serial measurement of human chorionic gonadotrophin (HCG) concentration is reported here for the first time to study the local vascularity of a cornual pregnancy and to monitor the effectiveness of medical therapy. Interestingly, a strong relationship between morphological changes of trophoblastic tissue and the intensity of neovascularization was noted. Systemic single-dose methotrexate (MTX) therapy allowed successful treatment of an interstitial ectopic pregnancy involving part of the proximal portion of a tubal stump. We suggest that, by adding colour Doppler to conventional transvaginal ultrasonography, the outpatient surveillance of ectopic pregnancy evolution following MTX therapy is greatly enhanced. This is of particular value in cornual pregnancies which are highly likely to develop harmful complications during surgical intervention or even during puncture for local MTX injection.

  12. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  13. Stratospheric temperature measurement with scanning Fabry-Perot interferometer for wind retrieval from mobile Rayleigh Doppler lidar.

    Science.gov (United States)

    Xia, Haiyun; Dou, Xiankang; Shangguan, Mingjia; Zhao, Ruocan; Sun, Dongsong; Wang, Chong; Qiu, Jiawei; Shu, Zhifeng; Xue, Xianghui; Han, Yuli; Han, Yan

    2014-09-08

    Temperature detection remains challenging in the low stratosphere, where the Rayleigh integration lidar is perturbed by aerosol contamination and ozone absorption while the rotational Raman lidar is suffered from its low scattering cross section. To correct the impacts of temperature on the Rayleigh Doppler lidar, a high spectral resolution lidar (HSRL) based on cavity scanning Fabry-Perot Interferometer (FPI) is developed. By considering the effect of the laser spectral width, Doppler broadening of the molecular backscatter, divergence of the light beam and mirror defects of the FPI, a well-behaved transmission function is proved to show the principle of HSRL in detail. Analysis of the statistical error of the HSRL is carried out in the data processing. A temperature lidar using both HSRL and Rayleigh integration techniques is incorporated into the Rayleigh Doppler wind lidar. Simultaneous wind and temperature detection is carried out based on the combined system at Delhi (37.371°N, 97.374°E; 2850 m above the sea level) in Qinghai province, China. Lower Stratosphere temperature has been measured using HSRL between 18 and 50 km with temporal resolution of 2000 seconds. The statistical error of the derived temperatures is between 0.2 and 9.2 K. The temperature profile retrieved from the HSRL and wind profile from the Rayleigh Doppler lidar show good agreement with the radiosonde data. Specifically, the max temperature deviation between the HSRL and radiosonde is 4.7 K from 18 km to 36 km, and it is 2.7 K between the HSRL and Rayleigh integration lidar from 27 km to 34 km.

  14. Evaluation of the predictive value of fetal Doppler ultrasound for neonatal outcome from the 36th week of pregnancy

    Directory of Open Access Journals (Sweden)

    Zahra Laleh Eslamian

    2018-01-01

    Full Text Available Background: Early prediction of adverse neonatal outcome would be possible by Doppler impedance indices of middle cerebral artery (MCA, umbilical artery (UmA, and descending aortal artery (AO that result in decrease neonatal morbidity and mortality rate. The aim of the present study was a determination of optimal value for the ratio of MCA to descending aorta blood flow (MCA/AO impedance indices and its comparison with the ratio of MCA to UmA (MCA/UmA impedance indices and their relationship with neonatal outcome. Materials and Methods: This was a prospective cohort study on 212 pregnant women with gestational age 36 weeks or more, in three hospitals in Tehran, from April 2012 to April 2013. We investigated AO, MCA, and UmA impedance indices Doppler ultrasound every 2 weeks till delivery. The mother was monitored for adverse pregnancy outcome (hypertension [HTN], fetal growth retardation, and other maternal complications then infant birth weight, cord blood of pH, and Neonatal Intensive Care Unit (NICU admission during the first 24 h after delivery were assessed. Finally, we investigated relationships between Doppler indices and neonatal outcomes include neonatal body weight (NBW, cord blood of pH, and NICU admission. Results: MCA/AO resistance index (RI and MCA/AO pulsatile index (PI showed an area under the receiver operating characteristics curve (area under the curve of 0.905 (95% confidence interval (CI: 0.850, 0.959 and 0.818 (95% CI: 0.679, 0.956, respectively. The cutoff values for pH (≥7.2 vs. <7.2 based on MCA/AO RI and MCA/AO PI indices were 0.951 (sensitivity, 80% and specificity, 86% and 0.853 (sensitivity, 91% and specificity, 83%, respectively. The cutoff value for NBW (≥2500 vs. <2500 g based on MCA/UmA PI index was 1.467 (sensitivity, 73% and specificity, 63%. The cutoff value of NICU admission of child based on MCA/AO PI index was 1.114 (sensitivity, 73% and specificity, 54%. Conclusion: In the end of third

  15. Early report: Comparison of breath-hold MR excretory urography, Doppler ultrasound and isotope renography in evaluation of symptomatic hydronephrosis in pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J.A.; Tomlinson, A.J.; Weston, M.J.; Lloyd, S.N

    2000-06-01

    AIM: To compare assessment by MR excretory urography (MREU), Doppler ultrasound and isotope renography of women with symptomatic hydronephrosis in pregnancy and to define its cause. MATERIALS AND METHODS: Eleven women at 19-34 weeks of gestation were studied prospectively with gadolinium-enhanced breath-hold gradient echo MREU and transabdominal Doppler ultrasound compared with a 'gold standard' of isotope renography employing frusemide challenge. All studies were performed within 24 h, were reported independently in a blinded fashion and employed clearly defined criteria. Obstetric and infant outcomes were obtained. RESULTS: There were no adverse reactions to gadolinium administration in pregnancy and no adverse obstetric or infant outcomes. Three of the 11 women were unable to tolerate the complete MREU protocol. Ultrasound indices could not be used to predict ureteric obstruction as shown by isotope renography. MREU agreed with renographic findings in five of the six cases with obstruction and in two without obstruction. MREU directly demonstrated hydronephrosis to result from extrinsic compression of the ureter between the gravid uterus and iliopsoas muscle. CONCLUSION: MR excretory urography is a promising technique which affords equivalent functional and additional anatomical information to isotope renography. It is more accurate than Doppler ultrasound in the assessment of ureteric obstruction in pregnancy. Spencer, J. A. (2000)

  16. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  17. Is there a relationship between ultrasound scanning ability (sonography) and visuospatial perception or psychomotor ability?

    Science.gov (United States)

    Hagen, Suzanne; Gallagher, Helen

    2016-01-01

    Background Competent sonography is thought to include a unique combination of skills not yet fully defined. This presents challenges when recruiting the correct people for training. Skills are thought to include visuospatial perception and psychomotor skills, but little is known about the relationship between these aptitudes and scanning ability. This feasibility study explored such relationships, to identify evaluation techniques which may improve selection and recruitment. Methods A sample of 30 experienced ultrasound practitioners and 30 trainees at commencement and on completion of training were administered eight tests. Results No significant relationships between experienced practitioners’ or trainees’ visuospatial abilities or psychomotor abilities and scanning abilities were found. Results demonstrated that two of the visuospatial perception tests were not influenced by training and therefore, may be measuring the innate skills of ultrasound practitioners. As ultrasound practitioners had not performed any of the tests previously, ranges of scores for each of the eight tests were established for this group. This included measures for psychomotor skills which added to the current body of knowledge for sonography. Conclusions Although no significant correlations were found between participants’ visuospatial perception or psychomotor abilities and scanning ability, performance on the Obstetric Structured Assessment Test (combining all the skills required) pre-training gave the best indication of post-training scanning performance. The Obstetric Structured Assessment Test may prove a useful tool for initial assessment of potential trainees but abilities will require further investigation. PMID:27847536

  18. Is there a relationship between ultrasound scanning ability (sonography) and visuospatial perception or psychomotor ability?

    Science.gov (United States)

    Chapman, Elizabeth; Hagen, Suzanne; Gallagher, Helen

    2016-11-01

    Competent sonography is thought to include a unique combination of skills not yet fully defined. This presents challenges when recruiting the correct people for training. Skills are thought to include visuospatial perception and psychomotor skills, but little is known about the relationship between these aptitudes and scanning ability. This feasibility study explored such relationships, to identify evaluation techniques which may improve selection and recruitment. A sample of 30 experienced ultrasound practitioners and 30 trainees at commencement and on completion of training were administered eight tests. No significant relationships between experienced practitioners' or trainees' visuospatial abilities or psychomotor abilities and scanning abilities were found. Results demonstrated that two of the visuospatial perception tests were not influenced by training and therefore, may be measuring the innate skills of ultrasound practitioners. As ultrasound practitioners had not performed any of the tests previously, ranges of scores for each of the eight tests were established for this group. This included measures for psychomotor skills which added to the current body of knowledge for sonography. Although no significant correlations were found between participants' visuospatial perception or psychomotor abilities and scanning ability, performance on the Obstetric Structured Assessment Test (combining all the skills required) pre-training gave the best indication of post-training scanning performance. The Obstetric Structured Assessment Test may prove a useful tool for initial assessment of potential trainees but abilities will require further investigation.

  19. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis [Department of Radiology, Medical School, University of Ioannina, 45110, Ioannina (Greece); Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani [Neonatology Clinic, Medical School, University of Ioannina, 45110, Ioannina (Greece); Vartholomatos, Georgios A. [Department of Haematology, Medical School, University of Ioannina, 45110, Ioannina (Greece)

    2003-08-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  20. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    International Nuclear Information System (INIS)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis; Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani; Vartholomatos, Georgios A.

    2003-01-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  1. Symmetrical modified dual tree complex wavelet transform for processing quadrature Doppler ultrasound signals.

    Science.gov (United States)

    Serbes, G; Aydin, N

    2011-01-01

    Dual-tree complex wavelet transform (DTCWT), which is a shift invariant transform with limited redundancy, is an improved version of discrete wavelet transform. Complex quadrature signals are dual channel signals obtained from the systems employing quadrature demodulation. An example of such signals is quadrature Doppler signal obtained from blood flow analysis systems. Prior to processing Doppler signals using the DTCWT, directional flow signals must be obtained and then two separate DTCWT applied, increasing the computational complexity. In this study, in order to decrease computational complexity, a symmetrical modified DTCWT algorithm is proposed (SMDTCWT). A comparison between the new transform and the symmetrical phasing-filter technique is presented. Additionally denoising performance of SMDTCWT is compared with the DWT and the DTCWT using simulated signals. The results show that the proposed method gives the same output as the symmetrical phasing-filter method, the computational complexity for processing quadrature signals using DTCWT is greatly reduced and finally the SMDTCWT based denoising outperforms conventional DWT with same computational complexity.

  2. Proximal splenic artery embolization for blunt splenic injury: clinical, immunologic, and ultrasound-Doppler follow-up.

    Science.gov (United States)

    Bessoud, Bertrand; Duchosal, Michel A; Siegrist, Claire-Anne; Schlegel, Susanna; Doenz, Francesco; Calmes, Jean-Marie; Qanadli, Salah D; Schnyder, Pierre; Denys, Alban

    2007-06-01

    To evaluate the clinical, US (ultrasound)-Doppler and hematologic findings after proximal splenic artery embolization (PSAE) for blunt injury. From August 1998 to February 2003, 37 patients (28 men and 9 women; 20-89 years old, mean 40 years) underwent PSAE for blunt injuries. One patient required secondary splenectomy after PSAE. Early complications were investigated during the hospital stay. Delayed follow-up included review of the outpatient records, telephone interview, consultation, US-Doppler splenic study, Howell-Jolly body search, and serum antibody titer determinations (pneumococcus and Haemophilus influenzae B). No early postprocedural complications were depicted. Ten patients were lost on follow-up. Two patients had a telephone interview that revealed no complication. Twenty-four patients were examined 6 to 63 (mean 26) months after the embolization. No late complication was reported. Splenic measurements were in the normal range: length (53-110 mm; mean, 73), width (49-110 mm; 76), thickness (26-56 mm; 38), volume (61-508 mL; 226), standard ellipsoid formula volume (32-265 mL; 118), corrected volume (29-238 mL; 106), and splenic volumetric index (2.3-18.8; 8.4). The spleen was homogeneous in 23 patients (96%). Intrasplenic vascularization was present and splenic vein was patent in all patients. Howell-Jolly bodies were found in two patients. All patients (24 of 24) evaluated for exposure-driven immunity against Haemophilus Influenza b had sufficient immunity. Seventeen of the 18 patients (94%) evaluated for exposure-driven immunity against pneumococcus had sufficient immunity. Five of the six patients (83%) evaluated for pneumococcus vaccine response had a sufficient response. Proximal splenic artery embolization in blunt splenic injuries is a well-tolerated technique without major long-term impact on the splenic anatomy and immune function.

  3. Cluster headache: transcranial Doppler ultrasound and regional cerebral blood flow studies

    International Nuclear Information System (INIS)

    Dahl, A.; Russell, D.; Nyberg-Hansen, R.; Rootwelt, K.

    1990-01-01

    Transcranial Doppler and rCBF examinations were carried out in 25 cluster headache patients. Spontaneous glyceryl trinitrate (nitroglycerin) provoked attacks were accompanied by a bilateral decrease in middle cerebral artery blood flow velocities. This decrease was more pronounced on the symptomatic side, but the difference did not reach statistical significance. Mean hemispheric blood flow and rCBF were within normal limits during provoked attacks and similar to those found when patients were attack-free. During cluster periods middle cerebral artery velocities were significantly higher on the symptomatic side. Glyceryl trinitrate caused a bilateral middle cerebral artery velocity decrease which was significantly greater on the symptomatic side. Attacks provoked by glyceryl trinitrate appeared to begin when the vasodilatory effect of this substance was received. 17 refs., 2 figs., 5 tabs

  4. Current recommendations for the study of carotid stenosis by doppler ultrasound and other imaging techniques

    International Nuclear Information System (INIS)

    Perez Matamoros, Angelica

    2012-01-01

    Ischemic cerebrovascular disease has been one of the most frequent causes of death from chronic disease, as well as cause of long-term disabilities, in both the United States, and in Latin American countries during recent years. It is therefore, important to know about it. An updated review of international recommendations to the Costa Rican health system is performed for carotid imaging study in patients at risk of accidents and ischemic cerebrovascular disease; with special emphasis on carotid Doppler ultrasonography, due to its wide availability in the medical field Costa Rican. Furthermore, certain relevant concepts of other imaging techniques currently available are listed to determine the appropriate choice of each method according to the individual patient's condition, such as conventional angiography and tomographic angiography [es

  5. Matlab-based interface for the simultaneous acquisition of force measures and Doppler ultrasound muscular images.

    Science.gov (United States)

    Ferrer-Buedo, José; Martínez-Sober, Marcelino; Alakhdar-Mohmara, Yasser; Soria-Olivas, Emilio; Benítez-Martínez, Josep C; Martínez-Martínez, José M

    2013-04-01

    This paper tackles the design of a graphical user interface (GUI) based on Matlab (MathWorks Inc., MA), a worldwide standard in the processing of biosignals, which allows the acquisition of muscular force signals and images from a ultrasound scanner simultaneously. Thus, it is possible to unify two key magnitudes for analyzing the evolution of muscular injuries: the force exerted by the muscle and section/length of the muscle when such force is exerted. This paper describes the modules developed to finally show its applicability with a case study to analyze the functioning capacity of the shoulder rotator cuff. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  7. Midpregnancy Doppler ultrasound of the uterine artery in metformin- versus placebo-treated PCOS women: a randomized trial.

    Science.gov (United States)

    Stridsklev, Solhild; Carlsen, Sven M; Salvesen, Øyvind; Clemens, Ilka; Vanky, Eszter

    2014-03-01

    Metformin is used to reduce pregnancy complications in women with polycystic ovary syndrome (PCOS), although it is not approved for this indication and solid evidence is lacking. Midpregnancy Doppler ultrasound is one of the best methods for prediction of adverse pregnancy outcome. The objectives of the study were to investigate the following: 1) whether metformin treatment influenced the midpregnancy pulsatility index (PI) of the uterine artery; 2) whether metabolic or endocrine factors affect the PI of the uterine artery of PCOS women; and 3) whether PI predicted adverse pregnancy outcome in PCOS woman. This is a substudy of a randomized, placebo-controlled, double-blind, multicenter study conducted at 11 secondary care centers. We randomly assigned 273 pregnancies to receive metformin or placebo, from the first trimester of pregnancy to delivery. In the present substudy, 231 pregnancies are included, ie, those who completed the ultrasound examinations. Midpregnancy PI in the uterine artery related to metformin use, androgen levels, an oral glucose tolerance test, and insulin levels was measured. We found no difference in the PI between the metformin and placebo groups. In multivariate analyses, fasting serum glucose of the first and second trimester correlated positively to the midpregnancy PI. Only in univariate analyses a weak correlation between androstenedione and PI was seen. Metformin treatment did not affect uterine artery blood flow, measured by PI. High fasting blood glucose correlated inversely to uterine artery blood flow. The midpregnancy PI correlated positively to preeclampsia, hypertension, and gestational diabetes mellitus in PCOS pregnancies. Androgen levels correlated only to PI in univariate analyses.

  8. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  9. Evaluation the index of ophthalmic arteries in diabetic patients with retinopathy compared to diabetic patients without retinopathy using color Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Mohammad Ghasem Hanafi

    2016-12-01

    Full Text Available Diabetic retinopathy is the most common eye complication in diabetic patients that early detection of this complication is essential. The aim of this study was to evaluate ophthalmic artery index in diabetic retinopathy by Doppler ultrasound. . In this cross-sectional study, 64 patients were studied in 4 groups (healthy, diabetic without retinopathy, background retinopathy and proliferative retinopathy. Resistance index (RI and Pulsatile Index (PI were assessed by color Doppler ultrasound. The obtained data were analyzed by ANOVA and chi-square test and ROC curve. RI in diabetic patients with proliferative retinopathy has the highest mean (0.83 and the lowest mean was observed in healthy subjects (0.54 (P <0.001 as well as in PI, the highest rate was in diabetic patients with proliferative retinopathy (1.41 and the lowest was in healthy subjects (0.92 (P <0.001. The results of our study showed that the sensitivity, specificity, positive and negative predictive values and overall accuracy of RI and PI in diabetic patients with proliferative retinopathy in the best cut-off points (0.645 and 1.0175 respectively were 100%.Ophthalmic artery index RI and PI was significantly increased in patients with diabetic retinopathy and the sensitivity and specificity for detection retinopathy was 100%. Color Doppler ultrasound method is more efficient for screening diabetic patients with retinopathy.

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  13. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  14. A time-space synchronization of coherent Doppler scanning lidars for 3D measurements of wind fields

    DEFF Research Database (Denmark)

    Vasiljevic, Nikola

    This thesis consists of the results of a Ph.D. study that was focused on the development of the system of three time-space synchronized pulsed coherent Doppler scanning lidars, which are coordinated by a remote ’master computer’. This system has the unique capability to measure a complete three...... synchronization and time control of the emission, steering and acquisition were achieved, resulting that the complete lidar measurement process is controlled from the single hardware component. The system was formed using a novel approach, in which the master computer simultaneously coordinates the remote lidars...... through a UDP/IP and TCP/IP network by exchange of network packets. Since the size of the packets is roughly 1 kB, this approach allows an uninterrupted and fast coordination of the lidars, even in the case of mobile networks such as GSM. With this approach a maximum lag of 10 ms was observed in terms...

  15. Inferring common cognitive mechanisms from brain blood-flow lateralisation data obtained with functional transcranial Doppler ultrasound.

    Directory of Open Access Journals (Sweden)

    Georg eMeyer

    2014-06-01

    Full Text Available Current neuroimaging techniques with high spatial resolution constrain participant motion so that many natural tasks cannot be carried out. The aim of this paper is to show how a time-locked correlation-analysis of cerebral blood flow velocity (CBFV lateralisation data, obtained with functional TransCranial Doppler (fTCD ultrasound, can be used to infer cerebral activation patterns across tasks. In a first experiment we demonstrate that the proposed analysis method results in data that are comparable with the standard Lateralisation Index (LI for within-task comparisons of CBFV patterns, recorded during cued word generation (CWG at two difficulty levels.In the main experiment we demonstrate that the proposed analysis method shows correlated blood-flow patterns for two different cognitive tasks that are known to draw on common brain areas, CWG and Music Synthesis. We show that CBFV patterns for Music and CWG are correlated only for participants with prior musical training.CBFV patterns for tasks that draw on distinct brain areas, the Tower of London and CWG, are not correlated.The proposed methodology extends conventional fTCD analysis by including temporal information in the analysis of cerebral blood-flow patterns to provide a robust, non-invasive method to infer whether common brain areas are used in different cognitive tasks. It complements conventional high resolution imaging techniques.

  16. Does cerebral lateralization develop? A study using functional transcranial Doppler ultrasound assessing lateralization for language production and visuospatial memory.

    Science.gov (United States)

    Groen, Margriet A; Whitehouse, Andrew J O; Badcock, Nicholas A; Bishop, Dorothy V M

    2012-05-01

    In the majority of people, language production is lateralized to the left cerebral hemisphere and visuospatial skills to the right. However, questions remain as to when, how, and why humans arrive at this division of labor. In this study, we assessed cerebral lateralization for language production and for visuospatial memory using functional transcranial Doppler ultrasound in a group of 60 typically developing children between the ages of six and 16 years. The typical pattern of left-lateralized activation for language production and right-lateralized activation for visuospatial memory was found in the majority of the children (58%). No age-related change in direction or strength of lateralization was found for language production. In contrast, the strength of lateralization (independent of direction) for visuospatial memory function continued to increase with age. In addition, boys showed a trend for stronger right-hemisphere lateralization for visuospatial memory than girls, but there was no gender effect on language laterality. We tested whether having language and visuospatial functions in the same hemisphere was associated with poor cognitive performance and found no evidence for this "functional crowding" hypothesis. We did, however, find that children with left-lateralized language production had higher vocabulary and nonword reading age-adjusted standard scores than other children, regardless of the laterality of visuospatial memory. Thus, a link between language function and left-hemisphere lateralization exists, and cannot be explained in terms of maturational change.

  17. Polycystic Ovary Syndrome: The Correlation Between Renal Doppler Ultrasound and Laboratory Parameters

    Directory of Open Access Journals (Sweden)

    Elif Karadeli

    2014-12-01

    Full Text Available Aim: To investigate whether there is alteration both right and left kidney lenght, parenchymal thickness, renal arterial,venous blood flow measurements in normotensive reproductive age women with polycystic ovary syndrome (PCOS. Material and Method: Forty women with PCOS according to Rotterdam criteria and thirty-six healthy volunteers women were included in our study. Hormonal, biochemical analysis, renal Doppler ultrasonography were performed and were investigated in terms of both left and right renal lenght, parenchymal thickness, peak systolic velocity (PSV, resistive index (RI, venous impedance index (VI, metabolic characteristics having insulin resistance, impaired glucose tolerance, serum lipid concentration. The student t test and pearson corelation test were used for statistical analysis.Results: The measurements for kidneys were not different between women with PCOS and healthy women. The peak systolic velocity of mean renal artery was lower in PCOS group. The mean renal venous impedance also was higher in PCOS group than control group. The mean renal resistive index was slightly higher in PCOS but not statistical significant. In bivariate corelation analyse including all patients, it was seen that BMI, WHR, level of serum fasting glucose, insulin, LDL, trigliserides were positively related with mean renal length and mean parenchymal thickness measurements. Discussion: We found that there was alterations kidney blood flow in normotensive reproductive age women with PCOS. This findings may indicate results of long term renal and cardiovascular complications of PCOS.

  18. Transcranial Doppler ultrasound assessment of intracranial hemodynamics in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Dikanovic, M.; Balen, I.; Jandric, M.; Hozo, I.; Kokic, S.; Titlic, M.; Kadojic, D.

    2005-01-01

    Diabetics have a 3-fold risk for cardiovascular diseases compared with non-diabetics. This study was designed to evaluate cerebral hemodynamic changes related to type 2 diabetes mellitus (DM) with transcranial Doppler ultrasonography (TCD). TCD is a highly sensitive and specific method of quick bedside assessment of cerebrovascular circular circulation hemodynamics. In a prospective study, we compared a group of 100 patients with the diagnosis of type 2 diabetes mellitus (aged 48 to 67 years) and an age-and sex-matched control group of 100 healthy subjects without diabetes mellitus. We measured flow velocities (Vm) and the Gosling pulsatility index (PI) of the middle cerebral artery (MCA).The rate of TCD abnormalities was significantly higher in diabetic patients than in healthy control subjects (55% vs. 11%, P - 5 years, respectively. This study suggests that TCD is a useful marker for the detection of diabetic cerebrovascular changes. The duration and type of diabetes were found to have an impact on the development of pathologic cerebrovascular changes. (author)

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  1. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    Two morphological methods for quantifying the degree of stenoses in the iliac arteries, intravascular ultrasound (IVUS) and arteriography, were compared with duplex scanning, a method of evaluating the haemodynamic importance of the stenosis. A total of 38 patients, 20 women and 18 men, median age...... 66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... a blood vessel. Power Doppler is a newer technique that is more sensitive than color Doppler and ...

  4. Doppler ultrasound evaluation of cerebral blood flow pattern in neonates with congenital heart disease

    International Nuclear Information System (INIS)

    Kim, Tae Hoon; Kim, Mi Young; Kim, Yang Min; Lee, Soo Hyun; Kim, Soo Jin; Kim, Woong Han

    2003-01-01

    To evaluate intracerebral resistive index (RI) values in neonates with congenital heart disease and to investigate their changes after the corrective surgery of the congenital heart disease. Sixty nine neonates with congenital heart disease who underwent brain ultrasonography were included. Resistive index values were obtained at the genu portion of the anterior cerebral arteries through the anterior fontanelles. The patients were divided into 4 groups according to the presence of associated patent ductus arteriosus (PDA) and intracranial RI values. We evaluated the types of congenital heart disease that could influence RI values. Resistive index values were statistically higher in patients with PDA than in patients without PDA (p<0.05). RI values were higher in cases of large PDA with left-to-right shunt, but within the normal range in cases of small or nearly closing PDA or large PDA with bidirectional blood flow or with right-to-left shunt. For those patients without PDA, RI values were higher when patients had pulmonary atresia with multiple collateral vessels into the lung or when truncus arteriosus was present. RI values were also high in patients with hypoplastic left heart syndrome. RI values were normalized after the ligation of PDA, but patients with hypoplastic left heart syndrome showed persistently high RI values even after the Norwood's operation with Blalock-Taussig shunt. RI values are influenced by various congenital heart diseases except PDA. Therefore, the presences of the congenital heart disease and its hemodynamic changes should be taken into consideration in the evaluation of the intracranial RI values using Doppler ultrasonography.

  5. Using dynamic infrared thermography to optimize color Doppler ultrasound mapping of cutaneous perforators.

    Science.gov (United States)

    Muntean, Maximilian Vlad; Strilciuc, Stefan; Ardelean, Filip; Pestean, Cosmin; Lacatus, Radu; Badea, Alexandru Florin; Georgescu, Alexandru

    2015-12-01

    The high technical demands associated with perforator flaps demand a precise preoperative identification and evaluation of perforator vessels. Color Doppler Ultrasonography (CDU) and Dynamic Infrared Thermography (DIRT) are currently used for preoperative perforator mapping. Each individual technique has advantages and disadvantages. The purpose of this paper is to analyze the value of combining the two methods in order to optimize the process of preoperative perforator mapping. CDU and DIRT were used for preoperative perforator mapping in 10 pigs. The results were compared to intraoperative findings. Total number of perforators, localization, and identification of the dominant perforator was analyzed for each method. The examination time was recorded for each procedure. Both methods had a high sensitivity in determining the number and localization of perforators when compared to those identified during surgery. DIRT produced a higher number of false positive results. CDU accurately identified the emergence of the perforators in the fascia in all cases. Both methods correctly identified the dominant perforator. The sensitivity, positive predictive value, and accuracy of CDU were 93.56%, 97%, and 91.30% respectively and for DIRT 95.05%, 80.67%, and 77.41% respectively. The average examination was 39.76 minutes for CDU and 10.24 minutes for DIRT. The average time taken into account for the analysis of a single perforator in order to confirm DIRT findings was 1.83 minutes. Preoperative perforator mapping has become a compulsory step in nearly all reconstructive procedures. In our study, both CDU and DIRT correctly identified the dominant perforator in all cases. By combining the two examinations overall mapping time can be reduced significantly. A reduced examination time translates into increased patient compliance and a lower procedure cost. The combined mapping technique facilitates the selection of the ideal perforator in all cases. Correctly identifying the

  6. Processing methods for photoacoustic Doppler flowmetry with a clinical ultrasound scanner

    Science.gov (United States)

    Bücking, Thore M.; van den Berg, Pim J.; Balabani, Stavroula; Steenbergen, Wiendelt; Beard, Paul C.; Brunker, Joanna

    2018-02-01

    Photoacoustic flowmetry (PAF) based on time-domain cross correlation of photoacoustic signals is a promising technique for deep tissue measurement of blood flow velocity. Signal processing has previously been developed for single element transducers. Here, the processing methods for acoustic resolution PAF using a clinical ultrasound transducer array are developed and validated using a 64-element transducer array with a -6 dB detection band of 11 to 17 MHz. Measurements were performed on a flow phantom consisting of a tube (580 μm inner diameter) perfused with human blood flowing at physiological speeds ranging from 3 to 25 mm / s. The processing pipeline comprised: image reconstruction, filtering, displacement detection, and masking. High-pass filtering and background subtraction were found to be key preprocessing steps to enable accurate flow velocity estimates, which were calculated using a cross-correlation based method. In addition, the regions of interest in the calculated velocity maps were defined using a masking approach based on the amplitude of the cross-correlation functions. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.

  7. Utility of color Doppler transrectal ultrasound in the diagnosis of prostate cancer: a study of 101 cases; Utilidad de la ecografia transrectal con Doppler color en el diagnostico del cancer de prostata. Estudio de 101 casos

    Energy Technology Data Exchange (ETDEWEB)

    Morales, F. J.; Jornet, J.; Cervera, J.; Labrador, T. [Instituto Valenciano de Oncologia. Valencia (Spain)

    2001-07-01

    To determine the value of color Doppler ultrasound in the detection of prostate cancer. To relate asymmetries in vascularisation with the results of directed biopsy. Between May and November 2000, we studied 101 patients suspected of having prostate cancer. The selection criteria were a prostate-specific antigen level of over 3 ng/ml, suspicious digital rectal examination or both. The volume, capsule and internal architecture were assessed, focusing on nodules, suspicious hypoechoic areas and asymmetric color intensity. Sextant biopsies were carried out with an 18-gauge needle and samples were also taken of the areas of increased color intensity. (Author) 16 refs.

  8. Image analysis for beef quality prediction from serial scan ultrasound images

    Science.gov (United States)

    Zhang, Hui L.; Wilson, Doyle E.; Rouse, Gene H.; Izquierdo, Mercedes M.

    1995-01-01

    The prediction of intramuscular fat (or marbling) of live beef animals using serially scanned ultrasound images was studied in this paper. Image analysis, both in gray scale intensity domain and in frequency spectrum domain, were used to extract image features of tissue characters to get useful parameters for prediction models. One, 2 and 3 order multi-variable prediction models were developed from randomly selected data sets and tested using the remained data sets. The comparisons of prediction results between using serially scanned images and only final scanned ones showed good improvement of prediction accuracy. The correlation of predicted percent fat and actual percent fat increase from .68 to .80 and from .72 to .76 separately for two groups of data, the R squares increase from .65 to .68 and from .68 to .72, and the root of mean square errors decrease from 1.70 to 1.52 and from 1.22 to 1.12 separately. This study indicates that serially obtained ultrasound images from live beef animals have good potential for improving the prediction accuracy of percent fat.

  9. Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity

    NARCIS (Netherlands)

    Zhao, YH; Chen, ZP; Saxer, CE; Xiang, SH; de Boer, JF; Nelson, JS

    2000-01-01

    We have developed a novel phase-resolved optical coherence tomography (OCT) and optical Doppler tomography (ODT) system that uses phase information derived from a Hilbert transformation to image blood flow in human skin with fast scanning speed and high velocity sensitivity. Using the phase change

  10. Combined diagnosis of lateral cervical masses by RI-scintigraphy, ultrasound and CT-scanning

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kuang-Tsuong; Yamashita, Toshio; Sasa, Hidehiko

    1984-09-01

    Careful palpation, plain X-rays and angiography are useful in the diagnosis of lateral cervical masses, but accurate preoperative evaluation sometimes needs further examinations. Recently several new auxiliary procedures have become available such as RI-scintigraphy, Ultrasound, and CT-scanning but even these may not be sufficient when used singly. When all these procedures were combined preoperatively in the case of lateral cervical masses and the results were compared with the findings at time of surgery and the pathology of the extirpated masses, acurate preoperative diagnose were possible.

  11. Color Doppler imaging and measurements of intraovarian and intrauterine vascularization on basal ultrasound examination in spontaneous ovulatory and anovulatory cycles

    Directory of Open Access Journals (Sweden)

    Kutlešić Ranko

    2008-01-01

    Full Text Available Background/Aim. Any organs functioning directly depends on vascularization. It applies also to the uterus and ovary which go through changes of vascularization during a menstruation cycle. The aim of this investigation was to determine differences in intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4 between spontaneous ovulatory and anovulatory cycles. Methods. This prospective clinical investigation included 205 patients divided into two groups: with ovulatory and with anovulatory cycles. Results. Resistance to ovarian arterioral stromal blood flow was significantly lower in the patients with ovulatory cycles (pulsatile index - PI 0.97 ± 0.4 vs 1.93 ± 1.37; p = 0.001737; and (resistance index - RI 0.55 ± 0.12 vs 0.68 ± 0.14; p = 0.040033. There were no statistically significant differences in arcuate arterioral blood flow in the pateints with ovulatory and anovulatory cycles (PI 1.21 ± 0.34 vs 61 ± 0,61 p = 0.136161 and RI 0.64 ± 0.11 vs 0.74 ± 0.07; p = 0.136649. The patients with ovulatory cycles had lower uterine radial arterioral blood flow than the patients with anovulatory cycles (PI 1.001 ± 0.22 vs 1.61 ± 0.23 p = 0.007501 and RI 0.55 ± 0.08 vs 0.71 ± 0.12; p = 0,0460113. The patients with ovulatory cycles had lower subendometrial arterioral blood flow resistance (PI 0.69 ± 0.19 vs 1.385±0.09; p = 0.00622 and RI 0.44 ± 0.09 vs 0.65 ± 0.02; p = 0.027458. Conclusion. Color Doppler ultrasuond imaging and measurements of intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4, showed lower resistance to blood flow in ovulatory than in anovulatory cycles.

  12. Blood flow parameters in the short gastric vein and splenic vein on Doppler ultrasound reflect gastric variceal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Hitoshi, E-mail: maru-cib@umin.ac.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan); Ishihara, Takeshi, E-mail: ishihara@faculty.chiba-u.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan); Ishii, Hiroshi, E-mail: hiroshi.ishii@jfcr.or.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan); Tsuyuguchi, Toshio, E-mail: tsuyuguchi@faculty.chiba-u.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan); Yoshikawa, Masaharu, E-mail: yoshikawa@faculty.chiba-u.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan); Matsutani, Shoichi, E-mail: shoichi.matsutani@cchs.ac.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan); Yokosuka, Osamu, E-mail: yokosukao@faculty.chiba-u.j [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1, Inohana, Chuou-ku, Chiba 260-8670 (Japan)

    2010-07-15

    Purpose: Hemodynamic features associated with the bleeding from gastric fundal varices (FV) have not been fully examined. The purpose of this study was to elucidate hemodynamics in the short gastric vein (SGV) which is a major inflow route for FV and flow direction of the splenic vein (SV) in relation to bleeding FV. Materials and Methods: The subject of this retrospective study was 54 cirrhotic patients who had medium- or large-sized FV (20 bleeders, 34 non-bleeders) on endoscopy with SGV on both angiogram and sonogram. Diameter, flow velocity, flow volume of SGV and flow direction in the SV were evaluated by Doppler ultrasound. Results: Diameter, flow velocity and flow volume of SGV were significantly greater in bleeders (9.6 {+-} 3.1 mm, 11.4 {+-} 5.2 cm/s, 499 {+-} 250.1 ml/min) than non-bleeders (6.5 {+-} 2.2 mm, p = 0.0141; 7.9 {+-} 3.3 cm/s, p = 0.022; 205 {+-} 129.1 ml/min, p = 0.0031). SV showed forward flow in 37 (68.5%), to and fro in 3 (5.6%) and reversed flow in 14 patients (25.9%). The frequency of FV bleeding was significantly higher in case with reversed or 'to and fro' SV flow (11/17) than forward SV flow (9/37, p = 0.0043). The cumulative bleeding rate at 3 and 5 years was significantly higher in patients without forward SV flow (38.8% at 3 years, 59.2% at 5 years) than in patients with forward SV flow (18.7% at 3 years, 32.2% at 5 years, p = 0.0199). Conclusion: Advanced SGV blood flow and reversed SV flow direction may be a hemodynamic features closely related to the FV bleeding.

  13. The value of power Doppler ultrasound in patients with rheumatoid arthritis in clinical remission: Reclassifying disease activity?

    Science.gov (United States)

    Vergara, Facundo; Ruta, Santiago; Rosa, Javier; Marín, Josefina; García-Mónaco, Ricardo; Soriano, Enrique R

    2017-03-18

    The aim of the present study was to describe the ultrasound (US) findings in patients with rheumatoid arthritis (RA) in clinical remission, and to evaluate the ability of power Doppler (PD) US to reclassify disease activity in these patients. We included consecutive patients with RA according to 2010 American College of Rheumatology/European League Against Rheumatism criteria, who were in clinical remission by the Disease Activity Score (DAS28<2.6). Twenty joints of both hands were assessed by US. PD signal was evaluated on a semi-quantitative scale from 0 to 3. Three different US-modified DAS28 (US-DAS28) were constructed, replacing the clinical swollen joint count by the PD US joint count using PD score ≥1, ≥2 or ≥3, respectively. Eighty-six patients were included. Twenty-three (26.7%) patients had at least one joint with abnormal US-positive PD signal. Thirteen percent of patients were reclassified to low disease activity by applying the US-DAS28 when joints were considered active with a PD signal ≥1; 12%, when a PD signal ≥2 was considered, and 2% of the patients were reclassified when a PD score of 3 was considered. No patients were reclassified to a level of moderate or high activity applying US-DAS28. Although around a quarter of patients with RA in clinical remission showed PD US features indicating residual activity, only a small percentage were reclassified to a state of low activity and none to a level of moderate or high activity, applying the proposed US-DAS28. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  14. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  15. Muscle metastases: ultrasound and CT scan imaging in nine cases. Report on 9 cases

    International Nuclear Information System (INIS)

    Folinais, D.; Cluzel, Ph.; Blangy, S.; Sibert, A.; David, M.; Benacerraf, R.

    1988-01-01

    Clinical, ultrasound and CT scan examinations were carried out in 9 patients with secondary muscle lesions. All muscles can be affected but there was a marked predominance of psoas lesions (6 of the 9 cases). Two contrasting clinical pictures are seen. Secondary muscle tumors can occur during evolution of a known treated cancer (5 of the 9 cases), revealed usually by large, rarely painful, mass. CT scan imaging shows an heterogeneous mass taking up contrast and often partially necrotic, the lesions appearing hypoechogenic or heterogeneous on ultrasound exmination. Certain lesions can be totally necrotic. In some cases (4 of the 9 patients) the muscle metastases revealed the presence of a tumor. Symptomatology may be atypical and lead to a delay in diagnosis. Fine needle puncture biopsy can detect the secondary origin of the muscle lesion and also the primary tumor site (4 out of 9 cases), bronchopulmonary and colon cancer predominating. Images are however non-specific and in the absence of NMR imaging the muscle or lymph node metastases can be confused, although this has no practic consequences since treatment is identical [fr

  16. Automatic recognition of the common carotid artery in longitudinal ultrasound B-mode scans.

    Science.gov (United States)

    Rossi, Alessandro C; Brands, Peter J; Hoeks, Arnold P G

    2008-12-01

    Many morphological and dynamic properties of the common carotid artery (CCA), e.g. lumen diameter, distension and wall thickness, can be measured non-invasively with ultrasound (US) techniques. As common to other medical image segmentation processes, this requires as a preliminary step the manual recognition of the artery of interest within the ultrasound image. In real-time US imaging, such manual initialization procedure interferes with the difficult task of the sonographer to select and maintain a proper image scan plane. Even for off-line US segmentation the requirement for human supervision and interaction precludes full automation. To eliminate user interference and to speed up processing for both real-time and off-line applications, we developed an algorithm for the automatic artery recognition in longitudinal US scans of the CCA. It acts directly on the envelopes of received radio frequency echo signals, eventually composing the ultrasound image. In order to properly exploit the information content of the arterial structure the envelopes are decimated, according to the two-dimensional resolution characteristics of the echo system, thereby substantially decreasing computational load. Subsequently, based upon the expected diameter range and a priori knowledge of the typical pattern in the echo envelope of the arterial wall-lumen complex, parametrical template matching is performed, resulting in the location of the lumen position along each echo line considered. Finally, in order to reject incorrect estimates, a spatial and temporal clustering method is applied. Adequate values for the parameters involved in the processing are obtained via off-line testing of the proposed algorithm on 128 echo data recordings from 45 subjects. Using those robust parameter values, correct and fast recognition of the artery is achieved in more than 98% of the 6185 processed frames. Since these results are obtained via rigorous data decimation and using a cascade of rather simple

  17. Feasibility of dynamic 3-D color Doppler ultrasound for imaging penile vascular change in renal transplant patients with erectile dysfunction responding to sildenafil.

    Science.gov (United States)

    Chatterjee, Ratna; Deng, Jing; Pellerin, Denis; Todd-Pokropek, Andrew; Neild, Guy H; Lees, William R; Rodeck, Charles H

    2008-06-01

    Renal transplant recipients (RTRs) have a high incidence of erectile dysfunction (ED). Differentiation of penile vasculogenic impotence from other causes is important for treatment. Conventional 2-D color Doppler assessment after intracavernosal stimulant injection often fails to produce reliable results because of limited views by the cross-sectional imaging and the painful procedure. In comparison to the findings in three healthy volunteers, we determined cavernosal vascular hemodynamics in eight RTRs with ED before and after oral sildenafil by using live 3-D ultrasound and dynamic 3-D color Doppler. Results showed that, before sildenafil, penile arterial flow signals could only be reliably detected in one patient. After sildenafil, all had reliably detectable flow with grades II to III erection. Our data suggest that 3-D volumetric changes of the penis and its vasculature during erection can be studied by this technique and that this method could be useful for the evaluation of new drugs and therapeutic biofeedback.

  18. Novel Automatic Detection of Pleura and B-lines (Comet-Tail Artifacts) on In-Vivo Lung Ultrasound Scans

    DEFF Research Database (Denmark)

    Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse

    2016-01-01

    This paper presents a novel automatic method for detection of B-lines (comet-tail artifacts) in lung ultrasound scans. B-lines are the most commonly used artifacts for analyzing the pulmonary edema. They appear as laser-like vertical beams, which arise from the pleural line and spread down without...... fading to the edge of the screen. An increase in their number is associated with presence of edema. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Denmark) driving a 192-element 5.5 MHz wide linear transducer (10L2W, BK Ultrasound). The dynamic received...

  19. Ultrasound colour Doppler measurements in a single joint as measure of disease activity in patients with rheumatoid arthritis--assessment of concurrent validity

    DEFF Research Database (Denmark)

    Ellegaard, K; Torp-Pedersen, S; Terslev, L

    2009-01-01

    correlations were found. CONCLUSION: A standardized ultrasound examination of a single affected wrist joint in patients with RA may be used as a measure of disease activity. More studies are needed to identify the number of joints needed to examine by CDU to obtain the best validity of Doppler measurements...... investigated if the amount of CDU activity in a single joint can be used to quantify disease activity in RA. METHODS: A total of 109 patients with RA and affection of the wrist joint underwent a standardized CDU examination assessing three positions in their most affected wrist at start up in biological...

  20. The effect of isometric exercise of the hand on the synovial blood flow in patients with rheumatoid arthritis measured by color Doppler ultrasound

    DEFF Research Database (Denmark)

    Ellegaard, Karen; Torp-Pedersen, Søren; Lund, Hans

    2013-01-01

    made it possible to investigate the direct effect on blood supply in the synovium after training. In this case-control study, 24 patients with RA with USD activity in the wrist joint participated. The USD activity was measured by the color fraction (CF) (CF = colored pixels/total number of pixels......In 90% of patients with rheumatoid arthritis (RA), the joints of the hand are affected. Studies of grip strength training have not indicated a negative effect on disease activity after training. Introduction of ultrasound Doppler (USD) to measure increased blood flow induced by inflammation has...

  1. Novel automatic detection of pleura and B-lines (comet-tail artifacts) on in vivo lung ultrasound scans

    Science.gov (United States)

    Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Møller Sørensen, Hasse; Hemmsen, Martin Christian; Ewertsen, Caroline; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt

    2016-04-01

    This paper presents a novel automatic method for detection of B-lines (comet-tail artifacts) in lung ultrasound scans. B-lines are the most commonly used artifacts for analyzing the pulmonary edema. They appear as laser-like vertical beams, which arise from the pleural line and spread down without fading to the edge of the screen. An increase in their number is associated with presence of edema. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Denmark) driving a 192-element 5:5 MHz wide linear transducer (10L2W, BK Ultrasound). The dynamic received focus technique was employed to generate the sequences. Six subjects, among those three patients after major surgery and three normal subjects, were scanned once and Six ultrasound sequences each containing 50 frames were acquired. The proposed algorithm was applied to all 300 in-vivo lung ultrasound images. The pleural line is first segmented on each image and then the B-line artifacts spreading down from the pleural line are detected and overlayed on the image. The resulting 300 images showed that the mean lateral distance between B-lines detected on images acquired from patients decreased by 20% in compare with that of normal subjects. Therefore, the method can be used as the basis of a method of automatically and qualitatively characterizing the distribution of B-lines.

  2. Approach to treatment for obstructive jaundice of PTCD guided by combining ultrasound with X-ray scan

    International Nuclear Information System (INIS)

    Tang Huanliang; Cao Haoqian; Fei Jianguo

    2008-01-01

    Objective: To investigate the technical and clinical value of PTCD in patients with obstructive jaundice by the guiding of ultrasound combined with X-ray scan. Methods PTCD was performed in 58 patients with obstructive jaundice, with 47 patients malignant diseases and 11 patients benign diseases, guided by combining ultrasound and X-ray scan. 51 patients were punctured to right bile ducts and 7 cases were left bile ducts. Cholangiography was routinely used. Results: Technical success was obtained in all patients. No bleeding and biliary peritonitis were found after procedures. The bilirubin was reduced by 75.4ummol/L one week after operation. Conclusion: The technique of PTCD guided by combining ultrasound with X-ray scan was safe, simple, cost saving and less complications for obstructive jaundice. (authors)

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study may be part ...

  4. Penile vascular diagnostic categorization using penile duplex Doppler ultrasound: Differences in vascular hemodynamics parameters by differences in anatomic sampling location

    Directory of Open Access Journals (Sweden)

    Fabio Pezzoni

    2016-10-01

    Full Text Available Objectives. In 2013 the International Society for Sexual Medicine(ISSM published the guidelines regarding the standard operating procedure (SOP for penile duplex Doppler ultrasound (PDDU. Although ISSM-SOP have given important strides in reducing interobserver variability in PDDU by procedural protocol and parameters these guidelines do not address the anatomic location along the penis at which hemodynamic measurements have to be done. In our opinion a “double sampling” may be interesting to detect the arteriogenic or venogenic nature of the erectile dysfunction (ED. In particular sampling measurements at the “crus” (at the level of the peno-scrotal junction may be significative for detection of veno-occlusive dysfunction (VOD,whereas an evaluation at “mid penis” (1/2 distance between peno-scrotal junction and coronal sulcus, may be useful to diagnose an arterial insufficiency (AI. Material and Methods. We evalued 90 men, mean age 56.3, affected with ED of medium degree, responder to PDE5-I that urdergone to PDDU and also responder after pharmacologic intracavernosal injection (PIIof prostaglandin E1 20 mcg, with rigid erection and normal maintenance. We moreover evalued 90 men in youthful age (mean 35.2, in absence of vascular risk factors, no responder to PDE5-I that undergone to PDDU by PII at high dosage (bimix: prostaglandin E1 20 mcg, papaverine 20 mg. Results. In the first pool the sampling at “mid penis” resulted significative for arterial insuffciency (AI in 81% (73, in presence of normal or borderline end diastolic velocity (EDV. Sampling at the “crus” resulted negative for VOD in 90% (81. In the second pool, 66.6% (60 resulted responder with rigid erection and normal maintenance in presence of normal hemodynamic parameters: peak systolic velocity (PSV and end diastolic velocity (EDV both at the “crus” and at “mid penis” sampling. 33.4% (30 responded with a semirigid erection and manifested a constant

  5. Transverse cerebellar diameter on cranial ultrasound scan in preterm neonates in an Australian population.

    Science.gov (United States)

    Swaminathan, M; Davies, M; Davis, P; Betheras, F

    1999-08-01

    Fetal measurement of transverse cerebellar diameter (TCD) has been shown to correlate well with gestational age (GA), even in the presence of growth retardation. The aim of this study was to define the normal range of TCD in preterm neonates in an Australian population between 23 and 32 weeks GA. Infants admitted to the Royal Women's Hospital, Melbourne, having routine cranial ultrasound scans (asterion using a General Electric LOGIQ 500 scanner (GE Medical Systems, Waukesha, USA) and TCD measurement was taken in the coronal plane. 106 infants < 1500 g and/or of GA ultrasound in a group of preterm newborns, and forms the basis for nomograms of TCD which can be used as a tool to assist in the assessment of GA, even in growth-retarded preterm newborns, and in the diagnosis of cerebellar hypoplasia.

  6. A postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    International Nuclear Information System (INIS)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-01-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.)

  7. Postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-08-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.).

  8. Non-invasive assessment of fibrosis using color Doppler ultrasound in patients with hepatitis C virus in the Amazon rainforest, Brazil.

    Science.gov (United States)

    Leão, Jorge; Brock, Marianna; Castilho, Márcia; Scariot, André; Scariot, Ana; Braga, Wornei

    2012-02-01

    The purpose of this study was to correlate morphologic and hemodynamic Doppler ultrasound findings as indicators of the degree of inflammation and fibrosis and to diagnose chronic vital hepatitis complications and progression. A prospective, descriptive study of a case series was conducted that analyzed Doppler ultrasound images of the liver and portal system and used the portal vein congestion index, hepatic and splenic artery impedance indices, and the liver vascular index. Of 50 patients positive for antibodies against hepatitis C virus, morphologic changes highlighted increased hepatic parenchyma echogenicity in 24%, and increased gall blander echogenicity and wall thickness in 4%. The most common hemodynamic changes observed were reduced flow velocity in the portal vein trunk in 26%, congestion index changes in 12%, liver vascular index changes in 16%, and splenic and hepatic artery impedance index changes in 14%. These indices were shown to be associated with alanine aminotransferase levels, which suggested that they are important liver damage indicators in the early phase of infection with hepatitis C virus.

  9. Coronary sinus flow measured by pulsed Doppler ultrasound is a powerful indicator of coronary blood supply- a pig heart in vitro study.

    Science.gov (United States)

    Zheng, Xiao-Zhi; Wu, Jing; Hua, Jie

    2016-06-01

    To evaluate the correlation between the coronary sinus flow and the infusion volume in the coronaries and assess the performance of coronary sinus flow in predicting coronary artery occlusion in an isolated pig heart. The coronary sinus flow was measured in 16 isolated pig hearts by pulsed Doppler ultrasound. The correlation between the coronary sinus flow and the infusion volume in different coronary artery was analyzed, and the performance of coronary sinus flow in predicting different coronary artery occlusion was deducted. There were no statistically significant differences between the coronary sinus flow and the infusion volume in different coronary artery (p>0.05). The correlations between the coronary sinus flow and the infusion volume in left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), LAD and LCX, and LAD, LCX and right coronary artery (RCA) were all higher than 0.85 (p85% sensitivity and specificity. Excepting RCA mild occlusion (80% sensitivity and specificity. Conclusions The coronary sinus flow measured by pulsed Doppler ultrasound can effectively and exactly reflect the infusion volume in coronaries, which is a powerful indicator of coronary blood supply.

  10. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  11. Ultrasound colour Doppler is associated with synovial pathology in biopsies from hand joints in rheumatoid arthritis patients

    DEFF Research Database (Denmark)

    Andersen, Martin; Ellegaard, Karen; Hebsgaard, Josephine B

    2014-01-01

    -3). Data were clustered within patients, thus a linear mixed model was applied for the statistical tests. Parsimony in the statistical models was achieved omitting covariates from the model in the case of what was judged no statistical significance (p>0.1). RESULTS: Doppler colour fraction showed...... an association with the overall synovitis score (approximated Spearman, approximately r=0.43, p=0.003). The density of all immunohistochemical stainings showed a significant association with Doppler colour fraction: von Willebrand factor (approximately r=0.44, p=0.01), CD68 (approximately r=0.53, p=0.02), Ki67...... (approximately r=0.57, p=0.05) and CD3 (approximately r=0.57, p=0.0003). CONCLUSIONS: Colour Doppler activity is associated with the extent of inflammation present in the synovial biopsies from RA patients. However, synovial pathology was also seen in biopsies taken from Doppler negative sites....

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound images can help ... tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study ...

  13. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...

  14. Longitudinal microvascularity in achilles tendinopathy (power doppler ultrasound, magnetic resonance imaging time-intensity curves and the Victorian Institute of Sport Assessment-Achilles questionnaire): a pilot study

    International Nuclear Information System (INIS)

    Richards, Paula J.; McCall, Iain W.; Day, Christopher; Belcher, John; Maffulli, Nicola

    2010-01-01

    To evaluate the imaging of the natural history of Achilles tendinopathy microvascularisation in comparison with symptoms, using a validated disease-specific questionnaire [the Victorian Institute of Sport Assessment-Achilles (VISA-A)]. A longitudinal prospective pilot study of nine patients with post-contrast magnetic resonance imaging (MRI), time-intensity curve (TIC) enhancement, ultrasound (US) and power Doppler (PD) evaluation of tendinopathy of the mid-Achilles tendon undergoing conservative management (eccentric exercise) over 1 year. There were five men and four women [mean age 47 (range 30-62) years]. Six asymptomatic tendons with normal US and MRI appearance showed less enhancement than the tibial metaphysis did and showed a flat, constant, but very low rate of enhancement in the bone and Achilles tendon (9-73 arbitrary TIC units). These normal Achilles tendons on imaging showed a constant size throughout the year (mean 4.9 mm). At baseline the TIC enhancement in those with tendinopathy ranged from 90 arbitrary units to 509 arbitrary units. Over time, 11 abnormal Achilles tendons, whose symptoms settled, were associated with a reduction in MRI enhancement mirrored by a reduction in the number of vessels on power Doppler (8.0 to 2.7), with an improvement in morphology and a reduction in tendon size (mean 15-10.6 mm). One tendon did not change its abnormal imaging features, despite improving symptoms. Two patients developed contralateral symptoms and tendinopathy, and one had more abnormal vascularity on power Doppler and higher MRI TIC peaks in the asymptomatic side. In patient with conservatively managed tendinopathy of the mid-Achilles tendon over 1 year there was a reduction of MRI enhancement and number of vessels on power Doppler, followed by morphological improvements and a reduction in size. Vessels per se related to the abnormal morphology and size of the tendon rather than symptoms. Symptoms improve before the Achilles size reduces and the

  15. Longitudinal microvascularity in achilles tendinopathy (power doppler ultrasound, magnetic resonance imaging time-intensity curves and the Victorian Institute of Sport Assessment-Achilles questionnaire): a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Paula J. [University Hospital of North Staffordshire NHS Trust (UHNS), Stoke on Trent, Staffordshire (United Kingdom); Keele University, Keele, Staffordshire (United Kingdom); North Staffs. Royal Infirmary, X-ray Department, Stoke on Trent, Staffordshire (United Kingdom); McCall, Iain W. [Keele University, Keele, Staffordshire (United Kingdom); North Staffordshire NHS Trust, Stoke on Trent, Staffordshire (United Kingdom); Day, Christopher [University Hospital of North Staffordshire NHS Trust (UHNS), Stoke on Trent, Staffordshire (United Kingdom); Belcher, John [Cardiff University, Department of Primary Care and Public Health, North Wales Clinical School, Cardiff (United Kingdom); Maffulli, Nicola [Keele University, Keele, Staffordshire (United Kingdom)

    2010-06-15

    To evaluate the imaging of the natural history of Achilles tendinopathy microvascularisation in comparison with symptoms, using a validated disease-specific questionnaire [the Victorian Institute of Sport Assessment-Achilles (VISA-A)]. A longitudinal prospective pilot study of nine patients with post-contrast magnetic resonance imaging (MRI), time-intensity curve (TIC) enhancement, ultrasound (US) and power Doppler (PD) evaluation of tendinopathy of the mid-Achilles tendon undergoing conservative management (eccentric exercise) over 1 year. There were five men and four women [mean age 47 (range 30-62) years]. Six asymptomatic tendons with normal US and MRI appearance showed less enhancement than the tibial metaphysis did and showed a flat, constant, but very low rate of enhancement in the bone and Achilles tendon (9-73 arbitrary TIC units). These normal Achilles tendons on imaging showed a constant size throughout the year (mean 4.9 mm). At baseline the TIC enhancement in those with tendinopathy ranged from 90 arbitrary units to 509 arbitrary units. Over time, 11 abnormal Achilles tendons, whose symptoms settled, were associated with a reduction in MRI enhancement mirrored by a reduction in the number of vessels on power Doppler (8.0 to 2.7), with an improvement in morphology and a reduction in tendon size (mean 15-10.6 mm). One tendon did not change its abnormal imaging features, despite improving symptoms. Two patients developed contralateral symptoms and tendinopathy, and one had more abnormal vascularity on power Doppler and higher MRI TIC peaks in the asymptomatic side. In patient with conservatively managed tendinopathy of the mid-Achilles tendon over 1 year there was a reduction of MRI enhancement and number of vessels on power Doppler, followed by morphological improvements and a reduction in size. Vessels per se related to the abnormal morphology and size of the tendon rather than symptoms. Symptoms improve before the Achilles size reduces and the

  16. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  17. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  18. Risk of deep venous thrombosis in elective neurosurgical procedures: a prospective, Doppler ultrasound-based study in children 12 years of age or younger.

    Science.gov (United States)

    Scherer, Andrea G; White, Ian K; Shaikh, Kashif A; Smith, Jodi L; Ackerman, Laurie L; Fulkerson, Daniel H

    2017-07-01

    OBJECTIVE The risk of venous thromboembolism (VTE) from deep venous thrombosis (DVT) is significant in neurosurgical patients. VTE is considered a leading cause of preventable hospital deaths and preventing DVT is a closely monitored quality metric, often tied to accreditation, hospital ratings, and reimbursement. Adult protocols include prophylaxis with anticoagulant medications. Children's hospitals may adopt adult protocols, although the incidence of DVT and the risk or efficacy of treatment is not well defined. The incidence of DVT in children is likely less than in adults, although there is very little prospectively collected information. Most consider the risk of DVT to be extremely low in children 12 years of age or younger. However, this consideration is based on tradition and retrospective reviews of trauma databases. In this study, the authors prospectively evaluated pediatric patients undergoing a variety of elective neurosurgical procedures and performed Doppler ultrasound studies before and after surgery. METHODS A total of 100 patients were prospectively enrolled in this study. All of the patients were between the ages of 1 month and 12 years and were undergoing elective neurosurgical procedures. The 91 patients who completed the protocol received a bilateral lower-extremity Doppler ultrasound examination within 48 hours prior to surgery. Patients did not receive either medical or mechanical DVT prophylaxis during or after surgery. The ultrasound examination was repeated within 72 hours after surgery. An independent, board-certified radiologist evaluated all sonograms. We prospectively collected data, including potential risk factors, details of surgery, and details of the clinical course. All patients were followed clinically for at least 1 year. RESULTS There was no clinical or ultrasound evidence of DVT or VTE in any of the 91 patients. There was no clinical evidence of VTE in the 9 patients who did not complete the protocol. CONCLUSIONS In this

  19. [Uterine arteriovenous malformation as cause of uterine bleeding of sudden onset. Doppler ultrasound utility, other imaging methods and the minimally invasive treatment].

    Science.gov (United States)

    Hernández-Escobar, C E; Carrillo-Martínez, M A; Arroyo-Lemarroy, T; ZamoraMorales, M T; Garza-García, G A; Campos-Sanmiguel, E

    2016-08-01

    Uterine arteriovenous malformation is a rare disorder that can cause sudden life-threatening vaginal bleeding. To present the clinical features in addition to the use of office gynecologic ultrasound and other imaging techniques in the diagnosis and minimally-invasive treatment of a patient with sudden vaginal bleeding resulting from a uterine arteriovenous malformation. A 31 year old woman presented sudden onset vaginal bleeding requiring the transfusion of 3 units of red blood cells. An initial diagnosis of uterine arteriovenous malformation was made using an office gynecological ultrasound and Color Doppler sonography. The patient was referred to interventional radiology for confirmation of the diagnosis and patient care. The diagnosis and localization of the uterine arteriovenous malformation was confirmed using magnetic resonance imaging. Therapeutic management proceeded with superselective angiography and embolization of the supplying arteries resulting in immediate symptomatic resolution. The use of office gynecologic ultrasound in combination with other imaging techniques is an important tool in the diagnosis and localization of uterine arteriovenous malformation. Embolization of supplying arteries is considered a safe and effective therapeutic option due to advances in radiologic intervention techniques. Advantages of this procedure include a minimally-invasive technique, low morbidity and preservation of uterine function.

  20. Using the angiogenic factors sFlt-1 and PlGF with Doppler ultrasound of the uterine artery for confirming preeclampsia.

    Science.gov (United States)

    Bahlmann, Franz; Al Naimi, Ammar

    2016-11-01

    The aim of this study is to assess the value of the angiogenic factors for diagnosing preeclampsia and predicting the severity of manifestation. A secondary aim is assessing the combination of the uterine artery Doppler with the angiogenic factors for improving the diagnostic power. This is a prospective single center study in a tertiary referral hospital. This study includes 728 individual patients. Inclusion criteria were singleton pregnancies, a referral to the hospital with suspicion of preeclampsia and any one or combination of the following symptoms: headache, upper abdominal pain, edema, and hypertension. Patients with complications that would affect the course of the pregnancy, such as placenta praevia, premature preterm rupture of membranes, breech presentation, and fetal chromosomal or structural anomalies, were excluded from the study. Blood samples collection and uterine artery Doppler ultrasound were performed at time of recruitment. The differences in sFlt-1, PlGF, and their quotient among normal collective and patients with preeclampsia were analyzed. Doppler ultrasound was performed by one of four highly qualified sonographers. Wilcoxon-Mann-Whitney U test, Spearman's rank correlation, receiver operating characteristic curves, Chi-square test, and logistic regression were used in the analysis. A total of 1003 individual samples for the angiogenic factors were included in the analysis. 584 out of the recruited 728 patients had follow-up data with delivery information at the study hospital. Patients with preeclampsia show a significant increase in sFlt-1, which directly correlate with the increased severity of manifestation (Spearman's ρ 0.49). The sFlt-1 cut-off value of 5424 pg/ml confirms preeclampsia with 83.7 % sensitivity, 68.1 % specificity, and 24 % misclassification rate. Preeclampsia patients also show a significant decrease in PlGF, which negatively correlates with the increased severity of manifestation (Spearman's ρ -0.39). A Pl

  1. 3D Catheter Shape Determination for Endovascular Navigation Using a Two-Step Particle Filter and Ultrasound Scanning.

    Science.gov (United States)

    Chen, Fang; Liu, Jia; Liao, Hongen

    2017-03-01

    In endovascular catheter interventions, the determination of the three-dimensional (3D) catheter shape can increase navigation information and help reduce trauma. This study describes a shape determination method for a flexible interventional catheter using ultrasound scanning and a two-step particle filter without X-ray fluoroscopy. First, we propose a multi-feature, multi-template particle filter algorithm for accurate catheter tracking from ultrasound images. Second, we model the mechanical behavior of the catheter and apply a particle filter shape optimization algorithm to refine the results from the first step. Finally, the acquired catheter's 3D shapes are displayed together with the preoperative 3D images of the cardiac structures to provide intuitive endovascular navigation. We validated our method using ultrasound scanning of the straight and curved catheters in a water tank, and the shape determination errors were 1.44 ± 0.38 mm and 1.95 ± 0.46 mm, respectively. Further, endovascular catheter shape determination was validated in a catheter intervention experiment with a heart phantom. The error of the acquired endovascular catheter shape was 2.23 ± 0.87 mm. These results demonstrate that our two-step method is both accurate and effective. Using ultrasound scanning for shape determination of a flexible catheter will be helpful in endovascular interventions, reducing exposure to radiation and providing rich navigation information.

  2. Investigation into the quantitative and qualitative characteristics of choroidal melanoma through magnetic resonance imaging and B-scan ultrasound

    Directory of Open Access Journals (Sweden)

    Papayiannis V

    2017-08-01

    Full Text Available Vassilis Papayiannis,1 Konstantinos T Tsaousis,2,3 Constantinos A Kouskouras,4 Afroditi Haritanti,4 Vasilios F Diakonis,5 Ioannis T Tsinopoulos2 1Department of Radiology, Papageorgiou General Hospital, 2Department of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 4Department of Radiology, AHEPA Aristotle University Hospital of Thessaloniki, Thessaloniki, Greece; 5Bascom Palmer Eye Institute, Miller School of Medicine, University of Miami, Miami, FL, USA Objective: To investigate the homogeneity and vascularity of choroidal melanoma through magnetic resonance imaging (MRI and brightness modulation (B-mode ultrasound scan and their correlation with dimensions of tumor, as well as to measure the sensitivity of both modalities in retinal detachment (RD detection.Materials and methods: This retrospective chart review included patients diagnosed with choroidal melanoma. All these patients underwent MRI scans using T2-weighted (T2-WI and T1-weighted (T1-WI sequences, before and after an intravenous injection of paramagnetic contrast material. The patients were also examined using a B-mode ultrasound scan, and the results from both modalities were compared (tumor homogeneity, tumor height, tumor base diameter, and tumor vascularity.Results: Forty-two patients (mean age =65.33±12.51 years with choroidal melanoma were included in the study. Homogeneity was confirmed in 16 patients through ultrasound scan, in 19 patients through T1-WI sequence, in 21 patients through T2-WI sequence, and in 25 patients through T1-WI sequence + contrast (gadolinium. Patients with homogenous tumors presented with lower (P=0.0045 mean height than that of those with nonhomogenous tumors, whereas no statistically significant difference was found for base diameter measurements (P=0.056. Patients with tumors of high vascularity presented with greater mean height (P=0.000638 and

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... called the Doppler effect). A computer collects and processes the sounds and creates graphs or color pictures ...

  6. Correlação entre o doppler da veia hepática direita com a biópsia transcutânea guiada pela ultrassonografia em hepatopatias Correlation between doppler of the right hepatic vein with ultrasound transcutaneous guided biopsy in liver diseases

    Directory of Open Access Journals (Sweden)

    Gleim Dias de Souza

    2012-12-01

    Full Text Available OBJETIVOS: Correlacionar os achados da biópsia transcutânea hepática guiada por ultrassonografia com os dados ultrassonográficos modo B e Doppler da veia hepática direita; comparar os padrões de onda entre os grupos de estudo (hepatopatas e controle (sadios; e avaliar se o Doppler da veia hepática direita serve como marcador de hepatopatia crônica. MÉTODOS: Foram estudados 38 pacientes portadores de hepatopatia crônica comprovada por sorologia e biópsia (grupo de estudo e dez pacientes sem hepatopatia sorológica (grupo controle, avaliados pela ultrassonografia modo B e Doppler. Os critérios histológicos foram a classificação da Sociedade Brasileira de Patologia de Hepatite Crônica. RESULTADOS: A ultrassonografia modo B e o Doppler diferenciaram os indivíduos portadores de hepatopatia crônica dos normais (p=0,047. Houve diferença significativa entre o grupo de estudo e o controle na comparação entre os achados histopatológicos, ultrassonográficos modo B e o Doppler nos padrões de onda da veia hepática direita (p=0,001. CONCLUSÃO: Foi possível correlacionar a biópsia hepática com a ultrassonografia modo B e o Doppler da veia hepática direita; os hepatopatas apresentaram alteração no fluxo da veia hepática direita e os normais não, sendo que o padrão de onda nos controles saudáveis foi trifásico e nos hepatopatas bifásico ou monofásico; e o Doppler da veia hepática direita serviu como marcador de hepatopatia crônica.OBJECTIVE: To correlate chronic liver disease diagnosed by transcutaneous liver biopsy guided by ultrasound, with ultrasound findings with B-mode and Doppler of the right hepatic vein; 2 to compare the wave patterns between the study group and the control group; 3 to compare the right hepatic vein Doppler findings with histopathology findings as a possible marker of chronic liver disease. METHODS: Were studied 38 patients with chronic liver disease diagnosed by biopsy and serology (study group

  7. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    International Nuclear Information System (INIS)

    Muessig, K.; Leibniz Center for Diabetes Research, Duesseldorf; University Hospital of Tuebingen; Schraml, C.; Schwenzer, N.F.; University Hospital of Tuebingen; Rietig, R.; Balletshofer, B.; Martirosian, P.; Haering, H.U.; Schick, F.; Claussen, C.D.

    2012-01-01

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  8. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Muessig, K. [University Hospital of Duesseldorf (Germany). Dept. of Metabolic Diseases; Leibniz Center for Diabetes Research, Duesseldorf (Germany). Inst. for Clinical Diabetology; University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Schraml, C.; Schwenzer, N.F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology; Rietig, R.; Balletshofer, B. [University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Martirosian, P.; Haering, H.U.; Schick, F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; Claussen, C.D. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology

    2012-12-15

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  9. To analysis and identify various kinds of strong echo signal of ocular-perforating injury by B-scan ultrasound

    Directory of Open Access Journals (Sweden)

    Rui-Juan Wang

    2014-05-01

    Full Text Available AIM: To analysis the diagnostic value of B-scan on various kinds of strong echo signal of ocular-perforating injury.METHODS: Totally 176 patients(176 eyeswith ocular-perforating injury underwent B-scan ultrasound examination. We observed the B-scan imaging findings of the lens, vitreous cavity, eyeball wall and retrobulbar space.RESULTS: All 176 patients(176 eyesunderwent B-scan ultrasound examination had strong echo. Vitreous hemorrhage was found in 146 cases, dislocation of lens in 4 cases, intraocular foreign body in 105 cases, intravitreous bubble in 1 case, retinal detachment in 34 cases, choroidal detachment in 23 cases, posterior scleral rupture in 9 cases. Every patient had two or more signs above, and had strong echo signal. All kinds of strong echo signal of the cases were summarized as follows: thick vitreous hemorrhage; intraocular foreign body; dislocation of the lens; intravitreous bubble.CONCLUSION: Because of anterior chamber hemorrhage, cataract, vitreous hemorrhage, eyelid swelling and noncooperation of patients, we couldn't examine the posterior segment. So B-scan provides a great help to the ophthalmologist. It is very sensitive and has specific images on the detachment of retina, intraocular foreign body, posterior scleral laceration, hemorrhagic choroidal detachment. Complex perforating injury of eyeball often appears some confusing strong echo signals, but B-scan can identify those images. Thus, it is irreplaceable by other examinations.

  10. Evaluation of ovarian blood flow by colour Doppler ultrasound: practical use for reproductive management in the cow.

    Science.gov (United States)

    Matsui, Motozumi; Miyamoto, Akio

    2009-09-01

    Transrectal real-time ultrasonography (US) has been developed as a research and practical tool in bovine reproduction. Non-invasive US observations have made it possible to provide real-time and serial analyses of ovarian morphological changes and fetal development and have generated new information on reproductive physiology during the bovine oestrous cycle and pregnancy. This has greatly contributed to an understanding of the real-time dynamics of follicular development. US has also allowed for more accurate diagnosis compared with rectal palpation in reproductive management in cattle. Practical applications of US include early diagnosis of pregnancy, identification of twin fetuses, detection of ovarian and uterine pathologies and determination of fetal sex. In recent years, local blood flow has been analysed in individual ovarian follicles and the corpus luteum (CL) in the cow using colour Doppler US. From these observations, it has been found that (1) the blood supply to follicles is closely related to follicular growth, atresia and ovulation, (2) the blood supply to the CL increases in parallel with its growth, and (3) there is an acute increase in blood flow in the mature CL prior to luteal regression. Colour Doppler US may provide an estimate of the physiological status of follicles and corpora lutea. For example, images of blood flow can be used to assess the thickness of the follicular wall and provide a differential diagnosis of follicular and luteal cysts. Assessment of the area of blood flow in the CL using colour Doppler imaging may offer a useful adjunct in estimating CL function, which could be applied to the diagnosis of non-pregnancy and fetal loss. The number of small follicles which have blood flow at the start of gonadotrophin treatment may be a useful index to predict the superovulatory response. With improvements in portability and cost-effectiveness, the evaluation of ovarian blood flow by colour Doppler US is likely to become widely used as

  11. Investigation into the quantitative and qualitative characteristics of choroidal melanoma through magnetic resonance imaging and B-scan ultrasound.

    Science.gov (United States)

    Papayiannis, Vassilis; Tsaousis, Konstantinos T; Kouskouras, Constantinos A; Haritanti, Afroditi; Diakonis, Vasilios F; Tsinopoulos, Ioannis T

    2017-01-01

    To investigate the homogeneity and vascularity of choroidal melanoma through magnetic resonance imaging (MRI) and brightness modulation (B-mode) ultrasound scan and their correlation with dimensions of tumor, as well as to measure the sensitivity of both modalities in retinal detachment (RD) detection. This retrospective chart review included patients diagnosed with choroidal melanoma. All these patients underwent MRI scans using T2-weighted (T2-WI) and T1-weighted (T1-WI) sequences, before and after an intravenous injection of paramagnetic contrast material. The patients were also examined using a B-mode ultrasound scan, and the results from both modalities were compared (tumor homogeneity, tumor height, tumor base diameter, and tumor vascularity). Forty-two patients (mean age=65.33±12.51 years) with choroidal melanoma were included in the study. Homogeneity was confirmed in 16 patients through ultrasound scan, in 19 patients through T1-WI sequence, in 21 patients through T2-WI sequence, and in 25 patients through T1-WI sequence + contrast (gadolinium). Patients with homogenous tumors presented with lower ( P =0.0045) mean height than that of those with nonhomogenous tumors, whereas no statistically significant difference was found for base diameter measurements ( P =0.056). Patients with tumors of high vascularity presented with greater mean height ( P =0.000638) and greater mean base diameter compared with those with tumors of low vascularity ( P =0.019543). RD was detected in 26 patients through T1-WI sequence, in 13 patients through T2-WI sequence, in 26 patients through T1-WI sequence + contrast, and in 32 patients through ultrasound scan, which proved to be the most sensitive modality. The height of choroidal melanoma was positively correlated with tumor's homogeneity. Melanomas of greater height were found to be less homogenous, due to increased degeneration and higher occurrence of intratumoral hemorrhage. In addition, choroidal melanoma's height was also

  12. Slow fetal growth between first and early second trimester ultrasound scans and risk of small for gestational age (SGA birth.

    Directory of Open Access Journals (Sweden)

    Marija Simic

    Full Text Available To investigate the association between fetal growth between first and early second trimester ultrasound scan and the risk of severe small for gestational age (SGA birth.This cohort study included 69 550 singleton pregnancies with first trimester dating and an early second trimester growth scan in Stockholm and Gotland Counties, Sweden between 2008 and 2014. Exposure was difference in biparietal diameter growth between observed and expected at the second trimester scan, calculated by z-scores. Risk of birth of a severe SGA infant (birth weight for gestational age by fetal sex less than the 3rd centile was calculated using multivariable logistic regression analysis and presented as adjusted odds ratio (aOR.Parietal growth less than 2.5 percentile between first and second trimester ultrasound examination was associated with elevated risk of being born severe SGA. (aOR 1.67; 95% Confidence Interval 1.28-2.18. The risks of preterm severe SGA (birth before 37 weeks and term severe SGA (birth 37 weeks or later were at similar levels, and risk of severe SGA were also elevated in the absence of preeclampsia, hypertensive diseases or gestational diabetes.Fetuses with slow growth of biparietal diameter at ultrasound examination in early second trimester exhibit increased risk of being born SGA independent of gestational age at birth and presence of maternal hypertensive diseases or diabetes mellitus.

  13. Slow fetal growth between first and early second trimester ultrasound scans and risk of small for gestational age (SGA) birth.

    Science.gov (United States)

    Simic, Marija; Stephansson, Olof; Petersson, Gunnar; Cnattingius, Sven; Wikström, Anna-Karin

    2017-01-01

    To investigate the association between fetal growth between first and early second trimester ultrasound scan and the risk of severe small for gestational age (SGA) birth. This cohort study included 69 550 singleton pregnancies with first trimester dating and an early second trimester growth scan in Stockholm and Gotland Counties, Sweden between 2008 and 2014. Exposure was difference in biparietal diameter growth between observed and expected at the second trimester scan, calculated by z-scores. Risk of birth of a severe SGA infant (birth weight for gestational age by fetal sex less than the 3rd centile) was calculated using multivariable logistic regression analysis and presented as adjusted odds ratio (aOR). Parietal growth less than 2.5 percentile between first and second trimester ultrasound examination was associated with elevated risk of being born severe SGA. (aOR 1.67; 95% Confidence Interval 1.28-2.18). The risks of preterm severe SGA (birth before 37 weeks) and term severe SGA (birth 37 weeks or later) were at similar levels, and risk of severe SGA were also elevated in the absence of preeclampsia, hypertensive diseases or gestational diabetes. Fetuses with slow growth of biparietal diameter at ultrasound examination in early second trimester exhibit increased risk of being born SGA independent of gestational age at birth and presence of maternal hypertensive diseases or diabetes mellitus.

  14. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study; Insuficiencia venosa cronica primaria de los miembros inferiores. Valoracion prequirurgica con ecografia Doppler duplex color

    Energy Technology Data Exchange (ETDEWEB)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F. [Hospital Lluis Xativa. Valencia (Spain)

    2000-07-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  15. Value of Abdominal Radiography, Colonic Transit Time, and Rectal Ultrasound Scanning in the Diagnosis of Idiopathic Constipation in Children: A Systematic Review

    NARCIS (Netherlands)

    Berger, Marjolein Y.; Tabbers, Merit M.; Kurver, Miranda J.; Boluyt, Nicole; Benninga, Marc A.

    2012-01-01

    Objective To perform a systematic review evaluating the value of abdominal radiography, colonic transit time (CTT), and rectal ultrasound scanning in the diagnosis of idiopathic constipation in children. Study design Eligible studies were those assessing diagnostic accuracy of abdominal radiography,

  16. Value of Abdominal Radiography, Colonic Transit Time, and Rectal Ultrasound Scanning in the Diagnosis of Idiopathic Constipation in Children : A Systematic Review

    NARCIS (Netherlands)

    Berger, Marjolein Y.; Tabbers, Merit M.; Kurver, Miranda J.; Boluyt, Nicole; Benninga, Marc A.

    Objective To perform a systematic review evaluating the value of abdominal radiography, colonic transit time (CTT), and rectal ultrasound scanning in the diagnosis of idiopathic constipation in children. Study design Eligible studies were those assessing diagnostic accuracy of abdominal radiography,

  17. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  18. Influence of recent exercise and skin temperature on ultrasound Doppler measurements in patients with rheumatoid arthritis - an intervention study

    DEFF Research Database (Denmark)

    Ellegaard, Karen; Torp-Pedersen, Søren; Henriksen, Marius

    2009-01-01

    separate days. The interventions were (i) isometric exercise of the muscles of the hand and forearm, (ii) heating and (iii) cooling of the hand. The amount of Doppler in the wrist joint was quantified by measuring the percentage of colour in the synovium-the colour fraction (CF). The CF values estimated.......78-1.33 percentage points. The other interventions did not affect the CF significantly, with P-values of 0.65 and 0.59 in the heating intervention and 0.49 in the exercise intervention. CONCLUSIONS: Cooling of the hand should, if possible, be avoided before a USD examination of the wrist in patients with RA, because...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... called the Doppler effect). A computer collects and processes the sounds and creates graphs or color pictures ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ...

  2. Medical Ultrasound Imaging.

    Science.gov (United States)

    Hughes, Stephen

    2001-01-01

    Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... saved. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of blood cells as ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  4. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients

    International Nuclear Information System (INIS)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I.

    2003-01-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs

  5. Ultrasound

    Science.gov (United States)

    ... chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard JH, Schaefer-Prokop CM, eds. ... by: Jason Levy, MD, Northside Radiology Associates, Atlanta, GA. Also ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  7. Combined Scanning Confocal Ultrasound Diagnostic and Treatment System for Bone Quality Assessment and Fracture Healing

    Data.gov (United States)

    National Aeronautics and Space Administration — The objectives of this study are to develop a combined diagnostic and treatment ultrasound technology for early prediction of bone disorder and guided acceleration...

  8. Diagnostic Ultrasound of Diffuse-Nodu lar Pleural Mesotheliomas — Echosemiotics, Growth Characteristics, and Scanning Techniques

    OpenAIRE

    D.V. Safonov; А.А. Sozinova

    2014-01-01

    The aim of the investigation was the optimization of chest ultrasound technique in the diagnosis of diffuse-nodular pleural mesotheliomas, development and systematization of their ultrasound semiotics. Materials and Methods. We studied the ultrasonic picture of 32 mesotheliomas (31 malignant), among them 30 — diffuse-nodular, 2 — focal. Results. There were developed the assessment criteria of diffuse-nodular mesothelioma echosemiotics: significant (over 15 mm) diffuse thickening of co...

  9. Preferences for a third-trimester ultrasound scan in a low-risk obstetric population: a discrete choice experiment.

    Science.gov (United States)

    Lynn, Fiona A; Crealey, Grainne E; Alderdice, Fiona A; McElnay, James C

    2015-10-01

    Establish maternal preferences for a third-trimester ultrasound scan in a healthy, low-risk pregnant population. Cross-sectional study incorporating a discrete choice experiment. A large, urban maternity hospital in Northern Ireland. One hundred and forty-six women in their second trimester of pregnancy. A discrete choice experiment was designed to elicit preferences for four attributes of a third-trimester ultrasound scan: health-care professional conducting the scan, detection rate for abnormal foetal growth, provision of non-medical information, cost. Additional data collected included age, marital status, socio-economic status, obstetric history, pregnancy-specific stress levels, perceived health and whether pregnancy was planned. Analysis was undertaken using a mixed logit model with interaction effects. Women's preferences for, and trade-offs between, the attributes of a hypothetical scan and indirect willingness-to-pay estimates. Women had significant positive preference for higher rate of detection, lower cost and provision of non-medical information, with no significant value placed on scan operator. Interaction effects revealed subgroups that valued the scan most: women experiencing their first pregnancy, women reporting higher levels of stress, an adverse obstetric history and older women. Women were able to trade on aspects of care and place relative importance on clinical, non-clinical outcomes and processes of service delivery, thus highlighting the potential of using health utilities in the development of services from a clinical, economic and social perspective. Specifically, maternal preferences exhibited provide valuable information for designing a randomized trial of effectiveness and insight for clinical and policy decision makers to inform woman-centred care. © 2013 Blackwell Publishing Ltd.

  10. Justifiability of amniocentesis on the basis of positive findings of triple test, ultrasound scan and advanced maternal age

    Directory of Open Access Journals (Sweden)

    Dragoslav Bukvic

    2011-05-01

    Full Text Available Objective. To assess the effectiveness of antenatal screening for chromosomal abnormalities based on maternal age (≥35 years, positive ultrasound findings or a positive triple test. Materials and methods. Retrospective six-year study. The pregnant women routinely underwent established clinical and laboratory practice at the Department of Medical Genetics between 1997 and 2003. The women’s case notes were examined to identify indications for karyotyping, gestation period and the outcome of karyotyping and pregnancy. Results. Invasive antenatal tests were performed on 1440 cases, 1168 (81.11% age 35(a, 72 (5.00% positive triple test (b, 24 (1.67% positive ultrasound scanning (c and 176 (12.2% other (psychological, personal reasons, etc (d. The overall positive predictive value was 1.67% (1.6%(a, 1.4% (b, 12.5% (c, 0.0% (d. The constructed model of logistic regression gave an odds-ratio of 8.647 for the “positive ultrasound result vs. maternal age ≥35” indication, while the odds-ratio for the triple test vs. maternal age ≥35 was 0.854. Conclusions. Amniocentesis and cytogenetic analysis of foetal karyotype should be presented as a diagnostic possibility to all women over 35 years. The application of biochemical markers was far from the expected results. If we compare results for indication positive ultrasound scanning vs. maternal age, an oddsratio of ~9 was obtained. These results demonstrate that the likelihood of obtaining positive results (i.e. the presence of chromosome alterations from an amniocentesis having this indication is almost 9 times higher than from having an amniocentesis performed solely for advanced maternal age.

  11. Vector Flow Imaging Compared with Conventional Doppler Ultrasound and Thermodilution for Estimation of Blood Flow in the Ascending Aorta

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2017-01-01

    (constant and pulsatile) estimation. The correlation coefficients for all flowrig evaluations were 0.99 indicating systematic bias. After bias correction, the percentage error was reduced to 11.5%, 12.6% and 15.9% for velocity and flow rate (constant and pulsatile) estimation. In the in vivo setup, TO, TEE......, after correction for the systematic bias found in the flowrig. TO is a reliable and precise method for velocity and flow rate estimation on a flowrig. However, TO with the present setup, is not interchangeable with PACTD for cardiac volume flow estimation, but is a reliable and precise angle......-independent ultrasound alternative for velocity estimation of cardiac flow....

  12. Brain unidentified bright objects ("UBO") in systemic lupus erythematosus: sometimes they come back. A study of microembolism by cMRI and Transcranial Doppler ultrasound.

    Science.gov (United States)

    Bortoluzzi, A; Padovan, M; Azzini, C; De Vito, A; Trotta, F; Govoni, M

    2016-02-01

    The objectives of this report are to assess the occurrence of microembolic signals (MES) detected by transcranial Doppler ultrasound (TCD) in systemic lupus erythematosus (SLE) patients with (NPSLE) and without (SLE) neuropsychiatric involvement, and to verify the correlation between MES, clinical characteristics, especially the patent foramen ovale (PFO), and the presence of punctuate T2-hyperintense white matter lesions (WMHLs) detected by conventional magnetic resonance imaging (cMRI). A TCD registration to detect MES from the middle cerebral artery was carried out in SLE and NPSLE patients after exclusion of aortic and/or carotid atheromatous disease. In all patients conventional brain magnetic resonance imaging (cMRI) and transesophageal echocardiography were performed. Patients were stratified in two groups, with and without WMHLs, and compared. Twenty-three SLE patients (16 NPSLE and seven SLE) were enrolled in the study. Overall MES were detected in 12 patients (52.1%), WHMLs were detectable in 15 patients (13 NPSLE and two SLE) while eight patients had normal cMRI (three NPSLE and five SLE). Matching TCD ultrasound and neuroimaging data, MES were detected in 10 (nine NPSLE and one SLE) out of 15 patients with WHMLs and in only two out of eight patients (two NPSLE and six SLE) with normal cMRI, both with NP involvement. A PFO was confirmed in all cases of MES detection. MES are frequent findings in SLE patients, especially in those with focal WMHLs detected by cMRI and correlating with PFO. These findings should be taken into account and suggest caution in the interpretation of cMRI pictures along with a careful evaluation of MES in patients with cMRI abnormalities that should be included in the workup of SLE patients. © The Author(s) 2015.

  13. Non-invasive transcranial ultrasound therapy based on a 3D CT scan: protocol validation and in vitro results

    Energy Technology Data Exchange (ETDEWEB)

    Marquet, F; Pernot, M; Aubry, J-F; Montaldo, G; Tanter, M; Fink, M [Laboratoire Ondes et Acoustique, ESPCI, Universite Paris VII, UMR CNRS 7587, 10 rue Vauquelin, 75005 Paris (France); Marsac, L [Supersonic Imagine, Les Jardins de la Duranne, 510 rue Rene Descartes, 13857 Aix-en-Provence (France)], E-mail: fabrice.marquet@espci.org

    2009-05-07

    A non-invasive protocol for transcranial brain tissue ablation with ultrasound is studied and validated in vitro. The skull induces strong aberrations both in phase and in amplitude, resulting in a severe degradation of the beam shape. Adaptive corrections of the distortions induced by the skull bone are performed using a previous 3D computational tomography scan acquisition (CT) of the skull bone structure. These CT scan data are used as entry parameters in a FDTD (finite differences time domain) simulation of the full wave propagation equation. A numerical computation is used to deduce the impulse response relating the targeted location and the ultrasound therapeutic array, thus providing a virtual time-reversal mirror. This impulse response is then time-reversed and transmitted experimentally by a therapeutic array positioned exactly in the same referential frame as the one used during CT scan acquisitions. In vitro experiments are conducted on monkey and human skull specimens using an array of 300 transmit elements working at a central frequency of 1 MHz. These experiments show a precise refocusing of the ultrasonic beam at the targeted location with a positioning error lower than 0.7 mm. The complete validation of this transcranial adaptive focusing procedure paves the way to in vivo animal and human transcranial HIFU investigations.

  14. Conjugating precision and acquisition time in a Doppler broadening regime by interleaved frequency-agile rapid-scanning cavity ring-down spectroscopy

    Science.gov (United States)

    Gotti, Riccardo; Gatti, Davide; Masłowski, Piotr; Lamperti, Marco; Belmonte, Michele; Laporta, Paolo; Marangoni, Marco

    2017-10-01

    We propose a novel approach to cavity-ring-down-spectroscopy (CRDS) in which spectra acquired with a frequency-agile rapid-scanning (FARS) scheme, i.e., with a laser sideband stepped across the modes of a high-finesse cavity, are interleaved with one another by a sub-millisecond readjustment of the cavity length. This brings to time acquisitions below 20 s for few-GHz-wide spectra composed of a very high number of spectral points, typically 3200. Thanks to the signal-to-noise ratio easily in excess of 10 000, each FARS-CRDS spectrum is shown to be sufficient to determine the line-centre frequency of a Doppler broadened line with a precision of 2 parts over 1011, thus very close to that of sub-Doppler regimes and in a few-seconds time scale. The referencing of the probe laser to a frequency comb provides absolute accuracy and long-term reproducibility to the spectrometer and makes it a powerful tool for precision spectroscopy and line-shape analysis. The experimental approach is discussed in detail together with experimental precision and accuracy tests on the (30 012) ← (00 001) P12e line of CO2 at ˜1.57 μm.

  15. Diagnostic efficacy of SonoVue, a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study.

    Science.gov (United States)

    Sidhu, P S; Allan, P L; Cattin, F; Cosgrove, D O; Davies, A H; Do, D D; Karakagil, S; Langholz, J; Legemate, D A; Martegani, A; Llull, J-B; Pezzoli, C; Spinazzi, A

    2006-01-01

    The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (pSonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (pSonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

  16. The use of real time ultrasound scanning as a teaching method of anatomy in an undergraduate sonography and medical imaging degree in an Australian university

    International Nuclear Information System (INIS)

    Bowman, A.; Lawson, C.; McKillup, S.

    2016-01-01

    Background: Real-time ultrasound scanning is increasing in popularity as a teaching tool for human anatomy because it is non-invasive, offers real-time 3-D anatomy and is cheaper than dissections. Aim: To assess real-time ultrasound scanning as a teaching method of human anatomy, and to determine what teaching methods medical imaging and sonography students consider effective for understanding human anatomy. Method: Surveys were distributed to two consecutive cohorts of first year medical imaging and medical sonography students at CQUniversity. Participation was voluntary. Comparisons among teaching methods were made using repeated measures ANOVA. Results: Real-time ultrasound scanning was the most preferred method of delivery for anatomy classes overall especially compared to computer programs, videos, 3-D radiological images and dissection. Specifically, students indicated that ultrasound scanning was the preferred method to encourage learning from experience (F 7,231  = 2.942, p = 0.006), to develop team skills (F 7,231  = 4.550, p < 0.006), to follow complex instructions (F 7,231  = 4.656 p < 0.001) and to appreciate anatomical variation (F 7,231  = 2.067, p = 0.048). Dissection was the least favoured teaching method. Conclusion: Real-time ultrasound scanning is a useful tool for teaching anatomy, and animal dissections are a poor substitute for the use of human cadavers. - Highlights: • Real-time ultrasound scanning is a valid teaching tool for human anatomy. • Real-time ultrasound is preferred by students compared to other teaching methods. • Dissection is the least favoured method to learn anatomy. • Ultrasound encourages learning from experience and develops team skills.

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  18. Use of vascular Doppler ultrasound to detect acute estradiol vascular effect in postmenopausal women Uso do Doppler vascular para detectar o efeito agudo do estradiol em mulheres na pós-menopausa

    Directory of Open Access Journals (Sweden)

    Ruth Clapauch

    2007-01-01

    Full Text Available OBJECTIVES: To report on a simple practical test for assessing acute estradiol vascular effects on healthy and unhealthy postmenopausal women. INTRODUCTION: Estradiol acts in the endothelium to promote vasodilatation through genomic and non-genomic mechanisms, but its vascular action may be impaired in diabetes mellitus, hypertension, smoking and obesity. METHODS: Nineteen postmenopausal women (nine healthy and 10 with two or more of the above factors of similar age and time since menopause were examined with vascular Doppler ultrasound. Resistance indexes and systolic and diastolic flow velocities were determined for the brachial and internal carotid arteries at baseline and 20 minutes after administration of a nasal estradiol formulation, available on the market, which reaches 1,200-1,500 pg/ml in the serum in 10-30 minutes. Estradiol blood levels were measured at 30 minutes. RESULTS: The carotid resistance index increased 14.2% (vasoconstriction in the unhealthy group after estradiol, from a mean ± S.E. of 0.56 ± 0.016 at baseline to 0.64 ± 0.05 (p=0.033, and remained unchanged in healthy women. Brachial diastolic flow velocity increased 19.7% (vasodilatation in healthy women, from 16.2 ± 1.93 to 19.4 ± 0.64 cm/s (p=0.046, and did not change in the unhealthy subjects. Estradiol levels were similar in both groups. DISCUSSION: Healthy postmenopausal women showed brachial vasodilatation while unhealthy postmenopausal women displayed vasoconstriction at the carotid artery. Vascular responses to estradiol were divergent between the groups. CONCLUSIONS: The acute estradiol test, coupled with Doppler ultrasound, seemed to be able to differentiate women with normal and abnormal endothelial function in a simple, non-invasive manner.OBJETIVO: Descrever um teste simples e prático para avaliar o efeito vascular agudo do estradiol em mulheres saudáveis e não-saudáveis na menopausa. INTRODUÇÃO: O estradiol atua no endotélio promovendo

  19. Doppler echography and utilization of intravenous echo enhancer in the follow-up of hepato carcinoma with percutaneous radiological techniques; Ecografia Doppler y empleo del ecopotenciador intravenoso en el seguimiento del hepatocarcinoma con tecnicas radiologicas percutaneas

    Energy Technology Data Exchange (ETDEWEB)

    Forner, J.; Flored de la Torre, M.; Senis, C.; Lozano de Arnilla, M. C.; Ferrer, S.; Celma, M. I. [Hospital General Universitario de Valencia. Valencia (Spain)

    2002-07-01

    To evaluate the utilization of Doppler ultrasound scan in conjunction with echographic enhancer in the follow-up of hepato carcinomas treated by means of radiological intervention techniques. We treated 20 hepatic nodules diagnosed with hepato carcinoma either by means of chemo embolization or percutaneously (either injection of acetic acid or radio-frequency thermo-ablation). Doppler ultrasound scan was performed before and after the treatment by means of sectorial and convex multifrequency probes. Evaluated were the absence, presence and degree of vascularisation, as well as its distribution and characteristics. In all cases, a contrast-en-handed spiral CT was performed. Both studies served as a pattern for comparison before and after treatment. In post-treatment enhanced-echo-Doppler controls of the 18 patients treated with acetic acid, vascularisation was not demonstrated in 7 cases, peripheral vascularisation was detected in 4 cases, perforation vascularisation in another four, and central vascularisation was detected in 3 cases. Contrast-enhanced spiral CT demonstrated superimposed findings, except in one cases, in which the spiral CT detected central capitation of the nodule.With enhanced echo-Doppler, peripheral vascularisation was detected. In both nodules treated by means of radio-frequency thermo ablation, there was detected neither vascularisation in the echo-Doppler nor captation of contrast media in the CT. Doppler ultrasound scan is a good method of follow-up for treated hepato carcinomas. The utilization of echoenhancers increases its ability to detect vascularization it being comparable to that of contrast-enhanced CT. As such, Doppler ultrasound scan together with echoenhancers can help us both in the selection of treatment and evaluation of therapeutic response. (Author) 35 refs.

  20. Can single use negative pressure wound therapy be an alternative method to manage keloid scarring? A preliminary report of a clinical and ultrasound/colour-power-doppler study.

    Science.gov (United States)

    Fraccalvieri, Marco; Sarno, Antonino; Gasperini, Stefano; Zingarelli, Enrico; Fava, Raffaella; Salomone, Marco; Bruschi, Stefano

    2013-06-01

    Keloid scarring represents a pathological healing where primary healing phenomenon is deviated from normal. Pico is a single use negative pressure wound therapy system originally introduced to manage open or just closed wounds. Pico dressing is made of silicone, and distributes an 80 mmHg negative pressure across wound bed. Combination of silicon layer and continuous compression could be a valid method to manage keloid scarring. Since November 2011, three patients were enrolled and evaluated before negative pressure treatment, at end of treatment (1 month) and 2 months later, through Vancouver Scar Scale (VSS), Visual Analog Scale (VAS) and a scoring system for itching. Ultrasound (US) and colour-power-doppler (CPD) examination was performed to evaluate thickness and vascularisation of the scar. One patient was discharged from study after 1 week. In last two patients, VSS, VAS and itching significantly improved after 1 month therapy and the results were stable after 2 months without any therapy. At end of therapy, the 'appearance of palisade vessels' disappeared in both cases at CPD exam; US showed a thickness reduction (average 43·8%). We propose a well-tolerated, non invasive treatment to manage keloid scarring. Prospective studies are necessary to investigate whether these preliminary observations are confirmed. © 2012 The Authors. International Wound Journal © 2012 John Wiley & Sons Ltd and Medicalhelplines.com Inc.

  1. Pulsed Wave Doppler Ultrasound Is Useful to Assess Vasomotor Response in Patients with Multiple System Atrophy and Well Correlated with Tilt Table Study

    Directory of Open Access Journals (Sweden)

    Ke-Vin Chang

    2012-01-01

    Full Text Available The study aim was to assess sympathetic vasomotor response (SVR by using pulsed wave Doppler (PWD ultrasound in patients with multiple system atrophy (MSA and correlate with the tilt table study. We recruited 18 male patients and 10 healthy men as controls. The SVR of the radial artery was evaluated by PWD, using inspiratory cough as a provocative maneuver. The response to head-up tilt was studied by a tilt table with simultaneous heart rate and blood pressure recording. The hemodynamic variables were compared between groups, and were examined by correlation analysis. Regarding SVR, MSA patients exhibited a prolonged latency and less heart rate acceleration following inspiratory cough. Compared with the tilt table test, the elevation of heart rate upon SVR was positively correlated to the increase of heart rate after head-up tilt. The correlation analysis indicated that the magnitude of blood pressure drop from supine to upright was positively associated with the SVR latency but negatively correlated with the heart rate changes upon SVR. The present study demonstrated that blunted heart rate response might explain MSA's vulnerability to postural challenge. PWD may be used to predict cardiovascular response to orthostatic stress upon head-up tilt in MSA patients.

  2. Refixation of Osteochondral Fractures by an Ultrasound-Activated Pin System - An Ovine In Vivo Examination Using CT and Scanning Electron Microscope.

    Science.gov (United States)

    H, Neumann; A P, Schulz; S, Breer; A, Unger; B, Kienast

    2015-01-01

    Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants a higher anchoring is assumed. Aim of the study was to investigate, if ultrasound-activated pins can provide a secure refixation of osteochondral fractures comparing to conventional screw and conventional, resorbable pin osteosynthesis. CT scans and scanning electron microscopy should proovegood refixation results with no further tissue damage by the melting of the ultrasound-activated pins in comparison to conventional osteosynthesis. Femoral osteochondral fragments in sheep were refixated with ultrasound-activated pins (SonicPin™), Ethipins(®) and screws (Asnis™). The quality of the refixated fragments was examined after three month of full weight bearing by CT scans and scanning electron microscopy of the cartilage surface. The CT examination found almost no statistically significant difference in the quality of refixation between the three different implants used. Concerning the CT morphology, ultrasound-activated pins demonstrated at least the same quality in refixation of osteochondral fragments as conventional resorbable pins or screws. The scanning electron microscopy showed no major surface damage by the three implants, especially any postulated cartilage damage induced by the heat of the ultrasound-activated pin. The screws protruded above the cartilage surface, which may affect the opposingtibial surface. Using CT scans and scanning electron microscopy, the SonicPin™, the Ethipin(®) and screws were at least

  3. How to Measure Size of Tubal Ectopic Pregnancy on Ultrasound Scan?

    Science.gov (United States)

    Rajah, K; Goodhart, V; Zamora, K P; Amin, T; Jauniaux, E; Jurkovic, D

    2017-11-16

    To identify the preoperative ultrasound measurements for assessing the size of tubal ectopic pregnancy which correlate best with the findings at surgery. We conducted a prospective study of all women with a conclusive transvaginal ultrasound diagnosis of tubal ectopic pregnancy over a 10-month period. In each case, we measured the total size of the ectopic pregnancy by placing the calipers on the outer edges of the visible trophoblastic tissue. In ectopic pregnancies, presenting with a well-defined gestational sac we also measured the size of coelomic (chorionic) cavity using the inner borders of the trophoblastic ring as the reference points. In women with signs of intraabdominal bleeding, we measured the size of the haematosalpinx and haemoperitoneum. The surgeons were blinded to the ultrasound measurements and they were asked to estimate the size of the ectopic pregnancy and the amount of haemoperitoneum intraoperatively. A total of 105 women were diagnosed with a tubal ectopic pregnancy on ultrasound examination out of which 71/105 (67.6%) were managed surgically. We found a significant (pectopic pregnancy as reported during surgery. In the absence of a haematosalpinx, the mean total outer diameter of ectopic pregnancy had the highest positive correlation with the size of tubal ectopic at surgery (r=0.65, Pectopic pregnancy at surgery. There was a significant (pectopic pregnancy on ultrasound correlate better with the surgical findings than the size of coelomic cavity. Our findings show that the standard approach to measure the size of intrauterine pregnancy on ultrasound should be adapted in women diagnosed with tubal ectopic pregnancies to include these additional measurements. This article is protected by copyright. All rights reserved.

  4. Shared brain lateralization patterns in language and Acheulean stone tool production: a functional transcranial Doppler ultrasound study.

    Science.gov (United States)

    Uomini, Natalie Thaïs; Meyer, Georg Friedrich

    2013-01-01

    The popular theory that complex tool-making and language co-evolved in the human lineage rests on the hypothesis that both skills share underlying brain processes and systems. However, language and stone tool-making have so far only been studied separately using a range of neuroimaging techniques and diverse paradigms. We present the first-ever study of brain activation that directly compares active Acheulean tool-making and language. Using functional transcranial Doppler ultrasonography (fTCD), we measured brain blood flow lateralization patterns (hemodynamics) in subjects who performed two tasks designed to isolate the planning component of Acheulean stone tool-making and cued word generation as a language task. We show highly correlated hemodynamics in the initial 10 seconds of task execution. Stone tool-making and cued word generation cause common cerebral blood flow lateralization signatures in our participants. This is consistent with a shared neural substrate for prehistoric stone tool-making and language, and is compatible with language evolution theories that posit a co-evolution of language and manual praxis. In turn, our results support the hypothesis that aspects of language might have emerged as early as 1.75 million years ago, with the start of Acheulean technology.

  5. Changes in cerebral haemodynamics in cases of post-lumbar puncture headache: a prospective transcranial Doppler ultrasound study

    International Nuclear Information System (INIS)

    Goebel, H.; Klostermann, H.; Lindner, V.; Schenkl, S.

    1990-01-01

    Transcranial Doppler ultrasonography was used in 45 patients to investigate if changes in haemodynamics in the major arteries of the brain base occurred after lumbar puncture and whether or not patients with or without post-lumbar puncture headache differ with respect to their cerebral haemodynamic parameters before and after lumbar puncture. Before lumbar puncture, patients with post-lumbar puncture headache differed from patients withoput post-lumbar puncture headache in that they showed significantly higher flow velocities and significant asymmetry of flow velocities with lateralization to the right. Patients without post-lumbar puncture headache, on the other hand, showed non-significant flow velocity lateralization to the left. Forty-eight hours after lumbar puncture, both groups demonstrated symmetrical flow velocities. In addition, only patients with post-lumbar puncture headache showed a significant reduction in the flow velocity of the right middle cerebral artery. These findings suggest that it is not only absolute flow velocity that plays a part in the event of headache; the interhemispheric relation of cerebral haemodynamics also plays a fundamental role. 14 refs., 3 figs., 2 tabs

  6. Refractive outcomes comparison between the Lenstar LS 900® optical biometry and immersion A-scan ultrasound.

    Science.gov (United States)

    Naicker, Palanyraj; Sundralingam, Siva; Peyman, Mohammadreza; Juana, Azida; Mohamad, Nor Fadhilah; Win, Maung Maung; Loo, Angela; Subrayan, Visvaraja

    2015-08-01

    To determine the accuracy of intraocular lens (IOL) calculations in eyes undergoing phacoemulsification cataract surgery with IOL implantation using immersion A-scan ultrasound (US) and Lenstar LS 900(®) biometry. In this prospective study, 200 eyes of 200 patients were randomized to undergo either Lenstar LS 900(®) or immersion A-scan US biometry to determine the IOL dioptric power prior to phacoemulsification cataract surgery. Post-operative refractive outcomes of these two groups of patients were compared. The result showed no significant difference between the target spherical equivalent (SE) and the post-operative SE value by the Lenstar LS 900(®) (p value = 0.632) or immersion A-scan US biometry (p value = 0.438) devices. The magnitude of difference between the two biometric devices were not significantly different (p value = 0.868). There was no significant difference in the predicted post-operative refractive outcome between immersion A-scan US biometry and Lenstar LS 900(®). Based on the results, the immersion A-scan US technique is as accurate as Lenstar LS 900(®) in the hands of an experienced operator.

  7. B-lines with Lung Ultrasound: The Optimal Scan Technique at Rest and During Stress.

    Science.gov (United States)

    Scali, Maria Chiara; Zagatina, Angela; Simova, Iana; Zhuravskaya, Nadezhda; Ciampi, Quirino; Paterni, Marco; Marzilli, Mario; Carpeggiani, Clara; Picano, Eugenio

    2017-11-01

    Various lung ultrasound (LUS) scanning modalities have been proposed for the detection of B-lines, also referred to as ultrasound lung comets, which are an important indication of extravascular lung water at rest and after exercise stress echo (ESE). The aim of our study was to assess the lung water spatial distribution (comet map) at rest and after ESE. We performed LUS at rest and immediately after semi-supine ESE in 135 patients (45 women, 90 men; age 62 ± 12 y, resting left ventricular ejection fraction = 41 ± 13%) with known or suspected heart failure or coronary artery disease. B-lines were measured by scanning 28 intercostal spaces (ISs) on the antero-lateral chest, 2nd-5th IS, along with the midaxillary (MA), anterior axillary (AA), mid-clavicular (MC) and parasternal (PS) lines. Complete 28-region, 16-region (3rd and 4th IS), 8-region (3rd IS), 4-region (3rd IS, only AA and MA) and 1-region (left 3rd IS, MA) scans were analyzed. In each space, the B-lines were counted from 0 = black lung to 10 = white lung. Interpretable images were obtained in all spaces (feasibility = 100 %). B-lines (>0 in at least 1 space) were present at ESE in 93 patients (69%) and absent in 42. More B-lines were found in the 3rd IS and along AA and MA lines. The B-line cumulative distribution was symmetric at rest (right/left = 1.10) and asymmetric with left lung predominance during stress (right/left = 0.67). The correlation of per-patient B-line number between 28-S and 16-S (R 2  = 0.9478), 8-S (R 2  = 0.9478) and 4-S scan (R 2  = 0.9146) was excellent, but only good with 1-S (R 2  = 0.8101). The average imaging and online analysis time were 5 s per space. In conclusion, during ESE, the comet map of lung water accumulation follows a predictable spatial pattern with wet spots preferentially aligned with the third IS and along the AA and MA lines. The time-saving 4-region scan is especially convenient during stress, simply dismissing dry regions and

  8. Comparison of the measurements of a novel optical biometry: Nidek AL-Scan with Sirius and a ultrasound biometry.

    Science.gov (United States)

    Çağlar, Çağatay; Kocamış, Sücattin İlker; Demir, Emre; Durmuş, Mustafa

    2017-06-01

    To investigate the accuracy of the measurements of Nidek AL-Scan by comparing with Sirius (CSO, Florence, Italy), a corneal tomography which also employs the Scheimpflug principle, and a commonly used device, ultrasound biometry (UB) (Aviso A/B, Quantel Medical, MT, USA). Right eyes of 85 healthy volunteers (58 women 27 men) with a mean age of 39.24 ± 14.37 years (range 15-68) were enrolled into this comparative prospective study. Average K 2.4, average K 3.3, CCT (central corneal thickness), WTW (white to white distance), ACD (anterior chamber depth) and AL (axial length) were obtained from the AL-Scan and compared with average SimK, CCT, WTW (horizontal anterior chamber diameter) and ACD obtained from Sirius and also compared with ACD and AL obtained from UB. The statistically significant difference was found between all of the measurements (p ACD parameter of AL-Scan and UB showed a perfect correlation (ICC = 0.977), there was a moderate correlation between AL-Scan and Sirius and also between UB and Sirius (ICC = 0.608 and 0.664, respectively). There was a high correlation between the all measurements, besides ACD, of AL-Scan and Sirius and they can be used interchangeably for average keratometry and WTW confidently. However, ACD and CCT have a broader 95 % LoA (-0.039 to 0.744 and -24.985 to 3.691, respectively). In addition, AL-Scan and UB were in good agreement regarding ACD, while differences in AL measurements of UB and AL-Scan were clinically important (95 % LoA = -0.091 to 0.703). Furthermore, UB and Sirius have a moderate agreement regarding ACD (95 % LoA = -0.047 to 0.680).

  9. Ultrasound scan in the diagnosis of neonatal renal candidiasis; Ecografia en el diagnostico de la candidiasis renal neonatal

    Energy Technology Data Exchange (ETDEWEB)

    Muro, D.; Sanguesa, C.; Torres, D.; Berbel, O.; Andres, V. [Hospital Infantil La Fe. Valencia (Spain)

    2003-07-01

    To describe the most pertinent echographic findings regarding systemic and renal candidiasis in high-risk neonates. Echographic findings and clinical histories of 40 neonates in the neonatal intensive care unit were retrospectively analyzed. Thirty-eight presented systemic candidiasis with renal participation, while two showed only renal candidiasis. Ultrasound scans were performed using 7.5 MHz probes. Alterations in renal echo structure, presence of echogenic material without acoustic shadowing in the excretory system (mycetoma), presence of lithiasis, pyonephrosis and associated renal malformations were all evaluated. Ten patients presented renal alterations in ultrasound scan. Six children had originally shown increased eye-catching in the renal parenchyma which was resolved after medical treatment. Four children presented renal mycetoma, and in two there were renal malformations. Both of these exhibited a profile for pyonephrosis. One patient with renal mycetoma without urological abnormalities developed a lithiasis. Surgical intervention was unnecessary in all cases. The most common echographic findings in immature high-risk low-weight patients with systemic and renal candidiasis were alterations in the eye-catching of renal parenchyma and the presence of mycetoma. (Author) 22 refs.

  10. Assessment of the Performance of a Scanning Wind Doppler Lidar at an Urban-Mountain Site in Seoul

    Science.gov (United States)

    Park, S.; Kim, S. W.

    2017-12-01

    Winds in the planetary boundary layer (PBL) are important factors for accurate modelling of air quality, numerical weather prediction and conversion of satellite measurements to near-surface air quality information (Seibert et al., AE, 2000; Emeis et al., Meteorol. Z., 2008). In this study, we (1) evaluate wind speed (WS) and direction (WD) retrieved from Wind Doppler Lidar (WDL) measurements by two methods [so called, `sine-fitting (SF) method' and `singular value decomposition (SVD) method'] and (2) analyze the WDL data at Seoul National University (SNU), Seoul, to investigate the diurnal evolution of winds and aerosol characteristics in PBL. Evaluation of the two methods used in retrieving wind from radial velocity was done through comparison with radiosonde soundings from the same site. Winds retrieved using the SVD method from mean radial velocity of 15 minutes showed good agreement with radiosonde profiles (i.e., bias of 0.03 m s-1 and root mean square of 1.70 m s-1 in WS). However, the WDL was found to have difficulty retrieving signals under clean conditions (i.e., too small signal to noise ratio) or under the presence of near-surface optically-thick aerosol/cloud layer (i.e., strong signal attenuation). Despite this shortcoming, the WDL was able to successfully capture the diurnal variation of PBL wind. Two major wind patterns were observed at SNU; first of all, when convective boundary layer was strongly developed, thermally induced winds with large variation of vertical WS in the afternoon and a diurnal variation in WD showing characteristics of mountain and valley winds were observed. Secondly, small variation in WS and WD throughout the day was a major characteristic of cases when wind was largely influenced by the synoptic weather pattern.

  11. Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer.

    Energy Technology Data Exchange (ETDEWEB)

    Rohe, Daniel Peter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-24

    Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

  12. Ultrasound scan of the orbit with an immersion protection in patients with subatrophy and anophthalmos

    Directory of Open Access Journals (Sweden)

    E. N. Verigo

    2012-01-01

    Full Text Available We observed 73 patients with anophthalmos with different types of intraorbital implants, and subatrophy of the globe. For three- dimensional ultrasound image of the orbit we used a new immersion substation on the basis of compressed polyvinyl alcohol, which was placed between the probe and the eyelids, excluding «dead zone». Acoustic density of the orbital structure and orbital blood flowwere estimated.

  13. Model based assessment of vestibular jawbone thickness using high frequency 3D ultrasound micro-scanning

    Science.gov (United States)

    Habor, Daniel; Neuhaus, Sarah; Vollborn, Thorsten; Wolfart, Stefan; Radermacher, Klaus; Heger, Stefan

    2013-03-01

    Endosseous implants are well-established in modern dentistry. However, without appropriate therapeutic intervention, progressive peri-implant bone loss may lead to failing implants. Conventionally, the particularly relevant vestibular jawbone thickness is monitored using radiographic 3D imaging methods. Ionizing radiation, as well as imaging artifacts caused by metallic implants and superstructures are major drawbacks of these imaging modalities. In this study, a high frequency ultrasound (HFUS) based approach to assess the vestibular jawbone thickness is being introduced. It should be emphasized that the presented method does not require ultrasound penetration of the jawbone. An in-vitro study using two porcine specimens with inserted endosseous implants has been carried out to assess the accuracy of our approach. The implant of the first specimen was equipped with a gingiva former while a polymer superstructure was mounted onto the implant of the second specimen. Ultrasound data has been acquired using a 4 degree of freedom (DOF) high frequency (gingiva, gingiva former (first specimen) and superstructure (second specimen). The meshes are matched with a-priori acquired 3D models of the implant, the superstructure and the gingiva former using a best-fit algorithm. Finally, the vestibular peri-implant bone thickness has been assessed in the resulting 3D models. The accuracy of this approach has been evaluated by comparing the ultrasound based thickness measurement with a reference measurement acquired with an optical extra-oral 3D scanner prior to covering the specimens with gingiva. As a final result, the bone thicknesses of the two specimens were measured yielding an error of -46+/-89μm (first specimen) and 70+/-93μm (second specimen).

  14. Malignant hepatic tumors treated with percutaneous radio-frequency ablation: Comparison between contrast-enhanced color Doppler ultrasound and spiral CT in evaluating the therapeutic efficacy

    International Nuclear Information System (INIS)

    Yoon, Jung Hee; Han, Sang Suk; Cha, Sung Sook

    2002-01-01

    To compare contrast-enhanced color Doppler ultrasound (CECDUS) with spiral CT in the evaluation of the therapeutic efficacy of malignant hepatic tumors after radio-frequency ablation (RFA). During a recent 2 year period (April 1999 to March 2001). One hundred fifteen hepatic tumors (95 hepatocellular carcinomas and 20 metastases; mean diameter, 2.7 cm) from 83 consecutive patients (60 men and 23 women; mean age, 57 years) that were treated with RFA were included in this study. Both CECDUS and two-or three phase spiral CT were performed a day after RFA as the immediate follow-up study in most cases. Afterward, both imaging studies were alternatively performed on monthly basis, but when incomplete ablation was suspected on one follow-up imaging study, the other imaging study was performed within a week for comparison. For ultrasound contrast agent, a suspension of 2.5 g or 4.0 g Levovist (Schering AG, Berlin, Germany) with a concentration of 300 mg/mL was used. For evaluating the therapeutic efficacy, the presence of viable portion, either residual or recurrent, within the ablated tumor was determined on each imaging study. The criteria for viable portion were defined as focal or irregular enhancement at the periphery of the ablated tumor on the arterial or portal phase spiral CT images and intratumoral vascularities on CECDUS. The correspondence rate between both imaging studies was assessed to compare the diagnostic accuracy of both studies in evaluating a residual or recurrent tumor. In addition, their imaging findings were analyzed. Analyzing both imaging findings of 116 malignant hepatic tumors, the correspondence rate between CECDUS and CT obtained after 116 times of imaging studies was 91.4% (106/116). For the diagnosis of residual or recurrent tumors, the sensitivity, specificity and diagnostic accuracy of spiral CT were 71%, 99%, and 94%, respectively, while those of CECDUS were 87%, 99%, and 97%, respectively. As the immediate follow-up study, CECDUS seemed

  15. Ultrasound tissue Doppler imaging reveals no delay in abdominal muscle feed-forward activity during rapid arm movements in patients with chronic low back pain.

    Science.gov (United States)

    Gubler, Deborah; Mannion, Anne F; Schenk, Peter; Gorelick, Mark; Helbling, Daniel; Gerber, Hans; Toma, Valeriu; Sprott, Haiko

    2010-07-15

    Cross-sectional study. Comparison of the timing of onset of lateral abdominal muscle activity during rapid arm movements in patients with nonspecific chronic low back pain (cLBP) and back-pain-free controls. Rapid movements of the arm are normally associated with prior activation of trunk-stabilizing muscles in readiness for the impending postural perturbation. Using invasive intramuscular electromyography techniques, studies have shown that this feed-forward function is delayed in some patients with low back pain (LBP). Ultrasound tissue Doppler imaging (TDI) provides an ultrasound method for quantifying muscle activation in a noninvasive manner, allowing investigation of larger groups of patients and controls. Ninety-six individuals participated (48 patients with cLBP and 48 matched LBP-free controls). During rapid shoulder flexion, abduction, and extension, surface electromyographic signals from the deltoid and motion-mode TDI images from the contralateral lateral abdominal muscles were recorded simultaneously. The onset of muscle activity was given by changes in the tissue velocity of the abdominal muscles, as measured with TDI. Pain and disability in the patients were assessed using standardized questionnaires. Data were analyzed using repeated measures analysis of variance. In both groups, feed-forward activity of the lateral abdominal muscles was recorded during arm movements in all directions. The main effect of "group membership" revealed no significant difference between the groups for the earliest onset of abdominal muscle activity (P = 0.398). However, a significant "group x body side" interaction (P = 0.015) was observed, and this was the result of earlier onsets in the cLBP group than controls for the abdominal muscles on the right (but not left) body side. No relationship was found between the time of onset of the earliest abdominal muscle activity and pain intensity, pain frequency, pain medication usage, or Roland Morris disability scores. Patients

  16. Safety of thrombolytic therapy with rt-PA and transcranial color Doppler ultrasound (TCCS) combined with microbubbles: a histopathologic study on rabbit brain tissues.

    Science.gov (United States)

    Ren, Xinping; Wang, Yong; Wang, Yi; Chen, Hong; Chen, Li; Liu, Yi; Xu, Chengshi

    2015-04-01

    To evaluate effect of thrombolytic therapy with rt-PA (recombinant tissue plasminogen activator) and transcranial color Doppler ultrasound (TCCS) combined with microbubbles on histology of brain tissue. New Zealand rabbits were subjected to TCCS based thrombolytic therapy, in 8 groups depending on dose of rt-PA, exposure duration of TCCS and presence of attenuation by skull bone window, 2 animals/group: (1) skull+1/2 rt-PA+TCCS+MBs, 10 min, (2) skull+rt-PA+TCCS+MBs, 10 min, (3) skull+1/2 rt-PA+TCCS+MBs, 20 min, (4) skull+rt-PA+TCCS+MBs, 20 min, (5) skull+1/2 rt-PA+TCCS+MBs, 30 min, (6) skull+rt-PA+TCCS+MBs, 30 min, (7) 1/2 rt-PA+TCCS+MBs, 10 min, (8) 1/2 rt-PA+TCCS+MBs, 20 min. The brain tissues were harvested after therapies and submitted for microscopic, electronic microscope and immunohistochemical examination. The histological changes were scored. TCCS caused exposure duration dependent brain tissue damage. With attenuation by bone window, TCCS based therapies for 10-20 min caused minimal tissue damage. However, significant tissue damage was observed upon TCCS for 30 min in presence of skull bone window, presenting as hemorrhage, misdistribution of organelles, demyelination of nerve fibers, and thinning of basement membrane in blood-brain barrier, which was milder than that after 20 min of exposure to TCCS in absence of bone window. Dose of rt-PA did not affect brain histology in all groups. Short treatment of brain tissue with TCCS through a bone window is relative safe. And skull bone window protected brain tissue from TCCS induced damage. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Long-term Prognosis of Pulpal Status of Traumatized Teeth Exhibiting Contradictory Results between Pulp Sensibility Test and Ultrasound Doppler Flowmetry: A Retrospective Study.

    Science.gov (United States)

    Ahn, So-Yeon; Kim, Dohyun; Park, Sung-Ho

    2018-03-01

    In this retrospective study, we investigated long-term (over 3 years) follow-up results of teeth that exhibited contradictory results between the pulp sensibility test (thermal or electric pulp test) and ultrasound Doppler flowmetry (UDF) until 1 year after trauma to inspect the prognosis of the pulp. Data were collected from the records of trauma patients in our hospital between February 2012 and May 2015. The teeth that had continuously shown contrasting results on the pulp sensibility test and UDF until 1 year after trauma were chosen for the study. Cases with follow-up records of more than 3 years after trauma were finally included, and a retrospective chart review was performed. Data from 343 teeth in 147 patients who visited the hospital with traumatic dental injuries were examined. Among these, 13 teeth from 7 patients were included, and the record of each case was reviewed. All the subjects showed negative responses on the pulp sensibility test and positive responses on UDF until 1 year after trauma. Ultimately, 8 of the 13 teeth recovered pulp sensibility. Two teeth failed to recover pulp sensibility and became symptomatic; root canal treatment was performed on the teeth. The remaining 3 teeth belonged to patients suffering from nerve damage; therefore, the pulp sensibility test was not feasible. Based on this study, UDF can be effectively used for the evaluation of pulpal status in traumatized teeth. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Non-invasive assessment of bone quantity and quality in human trabeculae using scanning ultrasound imaging

    Science.gov (United States)

    Xia, Yi

    Fractures and associated bone fragility induced by osteoporosis and osteopenia are widespread health threat to current society. Early detection of fracture risk associated with bone quantity and quality is important for both the prevention and treatment of osteoporosis and consequent complications. Quantitative ultrasound (QUS) is an engineering technology for monitoring bone quantity and quality of humans on earth and astronauts subjected to long duration microgravity. Factors currently limiting the acceptance of QUS technology involve precision, accuracy, single index and standardization. The objective of this study was to improve the accuracy and precision of an image-based QUS technique for non-invasive evaluation of trabecular bone quantity and quality by developing new techniques and understanding ultrasound/tissue interaction. Several new techniques have been developed in this dissertation study, including the automatic identification of irregular region of interest (iROI) in bone, surface topology mapping (STM) and mean scattering spacing (MSS) estimation for evaluating trabecular bone structure. In vitro results have shown that (1) the inter- and intra-observer errors in QUS measurement were reduced two to five fold by iROI compared to previous results; (2) the accuracy of QUS parameter, e.g., ultrasound velocity (UV) through bone, was improved 16% by STM; and (3) the averaged trabecular spacing can be estimated by MSS technique (r2=0.72, pcurrent gold-standard method, i.e., DXA, while additional information are obtained by the QUS for predicting fracture risk by monitoring of bone's quality. The developed QUS imaging technique can be used to assess bone's quantity and quality with improved accuracy and precision.

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  1. CLINICOPATHOLOGICAL FACTORS ASSOCIATED WITH POSITIVE PREOPERATIVE AXILLARY ULTRASOUND SCANNING IN BREAST CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    Lona Jalini

    2016-01-01

    Full Text Available Background: Axillary lymph node status is the most important breast cancer prognostic factor. Preoperative axillary ultrasound examination (PAUS is used to triage patients for sentinel lymph node biopsy (SLNB or axillary lymph node dissection (ALND. We assessed the detection rate of lymph node metastases by PAUS in a screening unit and evaluated associations between clinicopathological factors and PAUS positivity. Patients and Methods: This was a single-centre retrospective analysis of data extracted from a hospital breast cancer database and clinical records. Clinical, radiological, and pathological and prognostic indices were compared between PAUS-positive and PAUS-negative patients subsequently found to have lymph node metastases on histopathological analysis. Results: Two hundred and two patients were eligible for analysis. 50.5% of lymph node-positive patients were correctly identified as PAUS positive. Patients with PAUS-positive lymph nodes had less favorable disease characteristics, namely clinically palpable lymph nodes, higher Nottingham prognostic (NPI index, high lymph node burden according to the European Society of Medical Oncology (ESMO group classification, and larger, grade 3 tumors with lymphovascular invasion and extranodal spread. Moreover, PAUS-positive patients had more macrometastases and lymph node involvement than PAUS-negative patients. Conclusion: PAUS-positive patients and PAUS-negative (SLNB-positive patients have different clinicopathological characteristics. The presence of LVI, extranodal spread, grade 3 histology, or large tumors with poor prognostic indices in PAUS-negative patients should be regarded with caution and perhaps prompt second-look ultrasound examination.

  2. Selective heating of soft tissue-bone interfaces during scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Hynynen, K.; De Young, D.; Roemer, R.; Kundrat, M.

    1987-01-01

    Bone heating has been a frequent problem with clinical hyperthermia treatments induced by plane ultrasonic transducers. In this study, detailed temperature distributions were measured in dogs' (5 dogs) thigh muscles and bone in vivo while focussed ultrasound was applied to elevate the muscle temperature next to the bone. Significantly higher temperature elevations were measured at the bone surface than in the target volume in front of the bone. The temperature distribution was sharp decreasing fast inside the bone and also in front of it. By using more sharply focussed and multiple beams the temperature elevation at the bone surface was reduced and by suitable choice of the distance between the bone surface and the acoustical focus almost uniform temperature could be induced in the overlying muscle tissue from the surface down to the bone - the bone surface being in the same temperature as the muscle. Similar result was obtained by using single, higher frequency focussed beam (3.58 MHz). Also the utilization of nonlinear ultrasonic propagation appeared to reduce bone heating. The results showed that by carefully planning ultrasound hyperthermia treatments, tissues close to bone can be heated without extensive temperature elevation at bone surface

  3. Clinical outcome and imaging changes after intraarticular (IA) application of etanercept or methylprednisolone in rheumatoid arthritis: Magnetic resonance imaging and ultrasound-Doppler show no effect of IA injections in the wrist after 4 weeks

    DEFF Research Database (Denmark)

    Boesen, M.; Boesen, L.; Jensen, K.E.

    2008-01-01

    Objective. To assess the magnetic resonance imaging (MRI) and ultrasound (US) changes in the wrist of patients with rheumatoid arthritis (RA) 4 weeks after an US guided intraarticular (IA) injection. Methods. Contrast enhanced MRI and US-Doppler were performed at baseline and 4 weeks after IA...... injection of either 40 mg methylprednisolone (n = 12) or 25 mg etanercept (n = 13) in 25 patients with RA taking disease modifying antirheumatic drugs with a therapy-resistant wrist joint. All injections were US guided. Results. There was an improvement in swollen target joint score (p .... Conclusion. In contrast to the clinical evaluation, imaging measures of relevance for the estimation of inflammation, US-Doppler, US RI, MRI synovitis, and bone-marrow edema did not change 4 weeks after a single IA injection of either methylprednisolone or etanercept in the wrist. Within the same period...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... called the Doppler effect). A computer collects and processes the sounds and creates graphs or color pictures ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Your child should wear loose, comfortable clothing and may be asked to wear a gown. What is ... within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound examination. ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... uterus and ovaries. top of page What will I experience during and after the procedure? Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is inserted into an opening of the body may produce minimal discomfort. If a Doppler ultrasound ...

  10. Quantification of iliac artery stenoses: a methodological comparative study between intravascular ultrasound, arteriography and duplex scanning

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, John Bøje Grønvall; Skovgaard, Lene T

    1998-01-01

    66 y, admitted for either PTA (n=18) or femoro-femoral crossover bypass surgery (n=20), were examined by IVUS, single plane arteriography and duplex scanning. The predictive value, sensitivity, specificity and kappa value of IVUS were higher than the corresponding values for arteriography. Logistic...... regression analysis found that IVUS had a predictive value (p=0.0003) for diagnosing significant stenosis as defined by duplex scanning, but arteriography did not (p=0.1). However, this difference in usefulness as predictors did not reach significance. The agreement between arteriography and IVUS...... was relatively good. The conclusion is that IVUS seems to be superior to single-plane arteriography in predicting hemodynamically significant stenoses as defined by duplex scanning....

  11. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in which needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as clots) narrowing of vessels tumors ...

  13. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Directory of Open Access Journals (Sweden)

    Chen Jen Shan

    2014-04-01

    Full Text Available PurposeWe developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US and computerized tomography (CT for needle´s entry angle calculation and to study factors that may interfere in this procedure.Materials and MethodsHeight, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD and ventral decubitus (VD, and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI.ResultsBMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001, whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI.ConclusionSCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined.

  14. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Chen Jen; Mazzucchi, Eduardo; Payão, Fabio; Gomes, Andrea Cavalanti; Baroni, Ronaldo Hueb; Torricelli, Fabio Cesar; Vicentini, Fabio Carvalho; Srougi, Miguel [Hospital das Clínicas, University of Sao Paulo Medical School, Sao Paulo, SP (Brazil)

    2014-03-15

    Purpose: We developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD) to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US) and computerized tomography (CT) for needle´s entry angle calculation and to study factors that may interfere in this procedure. Materials and Methods: Height, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD) and ventral decubitus (VD), and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI). Results: BMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001), whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI. Conclusion: SCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined. (author)

  15. Doppler sonographic findings in testicular microlithiasis

    Directory of Open Access Journals (Sweden)

    Selim Serter

    2008-08-01

    Full Text Available OBJECTIVE: The aim of this prospective study was to compare the resistive index (RI values, which is a parameter of testicular parenchymal perfusion, in testicular microlithiasis (TM cases and normal cases. MATERIALS AND METHODS: 2179 volunteers, all healthy men (17-42 years of age from the Annual Army Reserve Officer Training Corps training camp were included in the study. A screening scrotal ultrasound was performed and all men diagnosed with TM underwent a scrotal Doppler ultrasonography scan (US. US examinations were performed for subjects with TM and without TM as a control group and RI was determined. RESULTS: 53 men with TM were identified in the 2179 US. Spectral Doppler examination was applied to 50 randomly selected cases (100 testicles without TM and 92 testicles with TM, 39 cases (78 testicles with bilateral and 14 cases with unilateral involvement. However, 48 normal testicles (17 bilateral and 14 unilateral and 47 testicles with TM (15 bilateral and 17 unilateral, 10 of which were cases with bilateral TM where flow from the centripetal artery could be obtained and analyzed were included in the statistical analysis for resistive indices. There was no significant difference regarding the RI and spectral examinations between subjects with and without TM. An interesting finding was the twinkling artifact observed in three cases. CONCLUSION: Microliths did not alter the RI values and thus had no influence on testicular perfusion on Doppler US examination.

  16. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  17. Ovarian and uterine maturity assessed by pelvic ultrasound scanning in adolescent girls with anorexia nervosa at the start of treatment – correlation with the history of menstruation

    Directory of Open Access Journals (Sweden)

    Gabriela Jagielska

    2010-12-01

    Full Text Available In females, absence of at least three consecutive menstrual cycles when otherwise expected to occur or cessation of pubescence (primary and secondary amenorrhea are the symptoms of anorexia nervosa, secondary to hypogonadotropic hypogonadism. Disturbances in sexual organs are seen in inappropriate for age pelvic ultrasound scanning. The aim of the study was to determine the ovarian and uterine maturity at the onset of anorexia nervosa (AN in adolescence, using pelvic ultrasound scanning, and their relations to clinical factors describing the course of AN. Material and method: The group consisted of 38 adolescent girls with anorexia nervosa diagnosed acc. to ICD-10 criteria – mean age 14.3±2.1 years, mean age at the beginning of AN symptoms 13±2.3 years, mean BMI 14±1.6 kg/m2. On initial assessment, all girls underwent physical examination, clinical interview concerning AN symptoms and pelvic ultrasound scanning. Results: Sixteen patients (42% had primary amenorrhea. In 32% of patients cessation of menses occurred before a significant decrease in weight. Ovarian and uterine volumes significantly below the expected were found in 11 and 15 patients with secondary amenorrhea, respectively. The varian and uterine maturity was related to shorter duration of amenorrhea and longer duration of adequate menstruation before the onset of AN. There were no BMI differences between the groups with more and less mature ultrasound picture.

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  19. The Effect of Diacutaneous Fibrolysis on Patellar Position Measured Using Ultrasound Scanning in Patellofemoral Pain Syndrome Patients.

    Science.gov (United States)

    Fanlo-Mazas, Pablo; Bueno-Gracia, Elena; de Escudero-Zapico, Alazne Ruiz; Tricás-Moreno, José Miguel; Lucha-López, María Orosia

    2018-04-13

    Tightness or lack of flexibility of flexibility of several muscles of the thigh has been associated with patellofemoral-join pain. A tight iliotibial band can lead to laterally located patella and an abnormal patellar tracking pattern. Diacutaneous fibrolysis is commonly used to reduce muscle tightness, but no studies have evaluated the effects of this technique in the treatment of patellofemoral pain syndrome patients. To assess the effect of diacutaneous fibrolysis on patellar position in patients with patellofemoral pain syndrome. A single-group, pretest-posttest clinical trial. University of Zaragoza. 46 subjects with patellofemoral pain (20 males, 26 females (age 27.8 ± 6.9 years)). 3 sessions of diacutaneous fibrolysis. Patellar position measurement using real time ultrasound scanning, pain intensity measured with visual analogue scale and function measured with the Anterior Knee Pain Scale. The application of three sessions of diacutaneous fibrolysis significantly increased the patellar position at post-treatment evaluation (pdiacutaneous fibrolysis and at one week follow up.

  20. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some guid...

  1. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  2. Fetal cardiac stroke volume determination by four-dimensional ultrasound with spatio-temporal image correlation compared with two-dimensional and Doppler ultrasonography.

    Science.gov (United States)

    Rizzo, Giuseppe; Capponi, Alessandra; Cavicchioni, Ottavia; Vendola, Marianne; Arduini, Domenico

    2007-12-01

    To assess the agreement of stroke volume (SV) measured with two-dimensional (2D) ultrasonography with Doppler capability (vs) four-dimensional (4D) with spatiotemporal image correlation (STIC) in normal and growth restricted fetuses. 2D Doppler and 4D STIC were used to measure SV of 40 normal fetuses at 20 to 22 and 28 to 32 weeks, and 16 growth-restricted fetuses at 26 to 34 weeks of gestation. Intraclass correlation was used to evaluate the agreement between left and right SV obtained by the two techniques, and proportionate Bland-Altman plots constructed. The time necessary to obtain SV was analyzed. The intraclass correlation coefficient between 2D Doppler and 4D STIC measurements for the left ventricle were 0.977 and 0.980 for the right ventricle. The proportionate limits of agreement between the two methods were 18.7 to 23.9% for the left ventricle and - 20.9 to 21.7% for the right ventricle. The time necessary to measure SV was significantly shorter with 4D STIC (3.1 (vs) 7.9 min p < 0.0001) than with 2D Doppler. There is a good agreement between SV measured either by 2D Doppler or by 4D STIC. The 4D STIC represents a simple and rapid technique to estimate fetal SV and promises to become the method of choice. Copyright (c) 2007 John Wiley & Sons, Ltd.

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... that allows the physician to see and evaluate blood flow through arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such as the liver or kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer ...

  4. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  6. Predicting need for additional CT scan in children with a non-diagnostic ultrasound for appendicitis in the emergency department.

    Science.gov (United States)

    Nishizawa, Takuya; Maeda, Shigenobu; Goldman, Ran D; Hayashi, Hiroyuki

    2018-01-01

    This study aimed to determine which children with suspected appendicitis should be considered for a computerized tomography (CT) scan after a non-diagnostic ultrasound (US) in the Emergency Department (ED). We retrospectively reviewed patients 0-18year old, who presented to the ED with complaints of abdominal pain, during 2011-2015 and while in the hospital had both US and CT. We recorded demographic and clinical data and outcomes, and used univariate and multivariate methods for comparing patients who did and didn't have appendicitis on CT after non-diagnostic US. Multivariate analysis was performed using logistic regression to determine what variables were independently associated with appendicitis. A total of 328 patients were enrolled, 257 with non-diagnostic US (CT: 82 had appendicitis, 175 no-appendicitis). Younger children and those who reported vomiting or had right lower abdominal quadrant (RLQ) tenderness, peritoneal signs or White Blood Cell (WBC) count >10,000 in mm 3 were more likely to have appendicitis on CT. RLQ tenderness (Odds Ratio: 2.84, 95%CI: 1.07-7.53), peritoneal signs (Odds Ratio: 11.37, 95%CI: 5.08-25.47) and WBC count >10,000 in mm 3 (Odds Ratio: 21.88, 95%CI: 7.95-60.21) remained significant after multivariate analysis. Considering CT with 2 or 3 of these predictors would have resulted in sensitivity of 94%, specificity of 67%, positive predictive value of 57% and negative predictive value of 96% for appendicitis. Ordering CT should be considered after non-diagnostic US for appendicitis only when children meet at least 2 predictors of RLQ tenderness, peritoneal signs and WBC>10,000 in mm 3 . Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Fluid mechanics of human fetal right ventricles from image-based computational fluid dynamics using 4D clinical ultrasound scans.

    Science.gov (United States)

    Wiputra, Hadi; Lai, Chang Quan; Lim, Guat Ling; Heng, Joel Jia Wei; Guo, Lan; Soomar, Sanah Merchant; Leo, Hwa Liang; Biwas, Arijit; Mattar, Citra Nurfarah Zaini; Yap, Choon Hwai

    2016-12-01

    There are 0.6-1.9% of US children who were born with congenital heart malformations. Clinical and animal studies suggest that abnormal blood flow forces might play a role in causing these malformation, highlighting the importance of understanding the fetal cardiovascular fluid mechanics. We performed computational fluid dynamics simulations of the right ventricles, based on four-dimensional ultrasound scans of three 20-wk-old normal human fetuses, to characterize their flow and energy dynamics. Peak intraventricular pressure gradients were found to be 0.2-0.9 mmHg during systole, and 0.1-0.2 mmHg during diastole. Diastolic wall shear stresses were found to be around 1 Pa, which could elevate to 2-4 Pa during systole in the outflow tract. Fetal right ventricles have complex flow patterns featuring two interacting diastolic vortex rings, formed during diastolic E wave and A wave. These rings persisted through the end of systole and elevated wall shear stresses in their proximity. They were observed to conserve ∼25.0% of peak diastolic kinetic energy to be carried over into the subsequent systole. However, this carried-over kinetic energy did not significantly alter the work done by the heart for ejection. Thus, while diastolic vortexes played a significant role in determining spatial patterns and magnitudes of diastolic wall shear stresses, they did not have significant influence on systolic ejection. Our results can serve as a baseline for future comparison with diseased hearts. Copyright © 2016 the American Physiological Society.

  8. Aplicação da ultrassonografia colorida doppler em programas de transferência de embriões equinos Potential use of doppler ultrasound in equine embryo transfer programs

    Directory of Open Access Journals (Sweden)

    Jair Camargo Ferreira

    2011-06-01

    Full Text Available Os programas comerciais de transferência de embriões em éguas existem por mais de três décadas e são hoje uma das biotécnias mais utilizadas na reprodução assistida de equinos. O exame ultrassonográfico nos períodos pré e pós-cobertura de doadoras de embriões, assim como a avaliação de receptoras no momento da inovulação é de vital importância para o êxito de um programa de transferência de embriões. A ultrassonografia Doppler é uma técnica não-invasiva que permite a avaliação em tempo real da hemodinâmica do trato reprodutivo de animais de grande porte. Por fornecer detalhes anatômicos e informações imediatas sobre a fisiologia do fluxo sanguíneo de tecidos e órgãos, o exame doppler permite a avaliação do potencial ovulatório de folículos e do status funcional de corpo lúteo e útero, além de ser uma técnica auxiliar para o diagnóstico de distúrbios na hemodinâmica do sistema reprodutivo. Alterações na perfusão sanguínea dos futuros folículos dominantes são detectáveis em diferentes fases de seu desenvolvimento, como na divergência folicular e no período pré-ovulatório. A partir dessas informações, é possível determinar o princípio da atividade sexual e o momento ideal para o início de tratamentos superovulatórios e indutores de ovulação, assim como o momento mais apropriado para a realização de coberturas de éguas doadoras de embriões. A avaliação através do modo-Doppler do corpo lúteo e útero de éguas receptoras é também um instrumento auxiliar para a seleção de animais com perfil sérico de progesterona e ambiente uterino adequados para a sobrevivência do embrião e manutenção da gestação. Essa técnica pode ser útil ainda ao se avaliar a interação concepto-maternal. Apesar da aplicabilidade da tecnologia doppler dentro de programas de transferência de embriões, novos estudos visando a determinar padrões de normalidade e posterior caracterização de

  9. Ultrasonography and color Doppler in juvenile idiopathic arthritis: diagnosis and follow-up of ultrasound-guided steroid injection in the ankle region. A descriptive interventional study

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    The ankle region is frequently involved in juvenile idiopathic arthritis (JIA) but difficult to examine clinically due to its anatomical complexity. The aim of the study was to evaluate the role of ultrasonography (US) of the ankle and midfoot (ankle region) in JIA. Doppler-US detected synovial h...

  10. Contrast ultrasound using SonoVue for pelvic radiation with concurrent chemotherapy monitoring in stage I B-II cervical cancer; Apport de l'echographie Doppler avec injection de contraste pour la prise en charge des cancers du col de l'uterus de stades IB et II par chimioradiotherapie concomitante

    Energy Technology Data Exchange (ETDEWEB)

    Marret, H. [Hopital Bretonneau, Service de Gynecologie, 37 - Tours (France); Barillot, I. [Hopital Bretonneau, Service de Radiotherapie, 37 - Tours (France); Rolland, Y. [CRLCC Eugene-Marquis, 35 - Rennes (France); Leveque, J. [Hopital Anne-de-Bretagne, 35 - Rennes (France)

    2009-10-15

    The aim of the present study was to evaluate whether angiogenic parameters as assessed by trans vaginal color Doppler ultrasound and by enhanced cervix ultrasound may predict prognostic factors of stage I B greater than 4 cm and II cervical cancer treated by radio chemotherapy. A total of 40 patients with histologically proven advanced stage invasive cervical cancer will be evaluated by color Doppler, contrast ultrasound, and MRI before radiotherapy, after the second chemotherapy cycle and prior to surgery. Subjective assessment of the amount of vessels within the tumor (scanty-moderate or abundant) and resistance index (R.I.) will be recorded for Doppler, enhancement and washout period will be studied after injection of SonoVue for contrast ultrasound. All patients will have radical hysterectomy and pelvic lymph node dissection. Comparison with MRI results will be done. The main parameter studied will be persistence of tumor cells in the analysis of the radical hysterectomy. We expected to correlate contrast parameters with persistent disease in order to confirm ultrasound parameters that will be useful to monitor radio chemotherapy and to predict therapeutic answer of such treatment. (authors)

  11. Effectiveness of evaluating tumor vascularization using 3D power Doppler ultrasound with high-definition flow technology in the prediction of the response to neoadjuvant chemotherapy for T2 breast cancer: a preliminary report.

    Science.gov (United States)

    Shia, Wei-Chung; Chen, Dar-Ren; Huang, Yu-Len; Wu, Hwa-Koon; Kuo, Shou-Jen

    2015-10-07

    The aim of this study was to evaluate the effectiveness of advanced ultrasound (US) imaging of vascular flow and morphological features in the prediction of a pathologic complete response (pCR) and a partial response (PR) to neoadjuvant chemotherapy for T2 breast cancer.Twenty-nine consecutive patients with T2 breast cancer treated with six courses of anthracycline-based neoadjuvant chemotherapy were enrolled. Three-dimensional (3D) power Doppler US with high-definition flow (HDF) technology was used to investigate the blood flow in and morphological features of the tumors. Six vascularity quantization features, three morphological features, and two vascular direction features were selected and extracted from the US images. A support vector machine was used to evaluate the changes in vascularity after neoadjuvant chemotherapy, and pCR and PR were predicted on the basis of these changes.The most accurate prediction of pCR was achieved after the first chemotherapy cycle, with an accuracy of 93.1% and a specificity of 85.5%, while that of a PR was achieved after the second cycle, with an accuracy of 79.31% and a specificity of 72.22%.Vascularity data can be useful to predict the effects of neoadjuvant chemotherapy. Determination of changes in vascularity after neoadjuvant chemotherapy using 3D power Doppler US with HDF can generate accurate predictions of the patient response, facilitating early decision-making.

  12. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  13. Assessment of trabecular bone quality in human cadaver calcaneus using scanning confocal ultrasound and dual x-ray absorptiometry (DEXA) measurements

    Science.gov (United States)

    Qin, Yixian; Xia, Yi; Lin, Wei; Rubin, Clinton; Gruber, Barry

    2004-10-01

    Microgravity and aging induced bone loss is a critical skeleton complication, occurring particularly in the weight-supporting skeleton, which leads to osteoporosis and fracture. Advents in quantitative ultrasound (QUS) provide a unique method for evaluating bone strength and density. Using a newly developed scanning confocal acoustic diagnostic (SCAD) system, QUS assessment for bone quality in the real body region was evaluated. A total of 19 human cadaver calcanei, age 66 to 97 years old, were tested by both SCAD and nonscan mode. The scanning region covered an approximate 40×40 mm2 with 0.5 mm resolution. Broadband ultrasound attenuation (BUA, dB/MHz), energy attenuation (ATT, dB), and ultrasound velocity (UV, m/s) were measured. The QUS properties were then correlated to the bone mineral density (BMD) measured by DEXA. Correlations between BMD and QUS parameters were significantly improved by using SCAD as compared to nonscan mode, yielding correlations between BMD and SCAD QUS parameters as R=0.82 (BUA), and R=0.86 (est. BMD). It is suggested that SCAD is feasible for in vivo bone quality mapping. It can be potentially used for monitoring instant changes of bone strength and density. [Work supported by the National Space Biomedical Research Institute (TD00207), and New York Center for Biotechnology.

  14. Pulmonary Capillary Hemorrhage Induced by Different Imaging Modes of Diagnostic Ultrasound.

    Science.gov (United States)

    Miller, Douglas L; Dong, Zhihong; Dou, Chunyan; Raghavendran, Krishnan

    2018-05-01

    The induction of pulmonary capillary hemorrhage (PCH) is a well-established non-thermal biological effect of pulsed ultrasound in animal models. Typically, research has been done using laboratory pulsed ultrasound systems with a fixed beam and, recently, by B-mode diagnostic ultrasound. In this study, a GE Vivid 7 Dimension ultrasound machine with 10 L linear array probe was used at 6.6 MHz to explore the relative PCH efficacy of B-mode imaging, M-mode (fixed beam), color angio mode Doppler imaging and pulsed Doppler mode (fixed beam). Anesthetized rats were scanned in a warmed water bath, and thresholds were determined by scanning at different power steps, 2 dB apart, in different groups of six rats. Exposures were performed for 5 min, except for a 15-s M-mode group. Peak rarefactional pressure amplitude thresholds were 1.5 MPa for B-mode and 1.1 MPa for angio Doppler mode. For the non-scanned modes, thresholds were 1.1 MPa for M-mode and 0.6 MPa for pulsed Doppler mode with its relatively high duty cycle (7.7 × 10 -3 vs. 0.27 × 10 -3 for M-mode). Reducing the duration of M-mode to 15 s (from 300 s) did not significantly reduce PCH (area, volume or depth) for some power settings, but the threshold was increased to 1.4 MPa. Pulmonary sonographers should be aware of this unique adverse bio-effect of diagnostic ultrasound and should consider reduced on-screen mechanical index settings for potentially vulnerable patients. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  15. Aspectos morfológicos e hemodinâmicos do baço em indivíduos normais: estudo por ultra-som Doppler Morphological and hemodynamic features of the spleen in normal subjects: a Doppler ultrasound study

    Directory of Open Access Journals (Sweden)

    Denise Said Jannini

    2003-08-01

    Full Text Available ANTECEDENTES: A diversidade de técnicas de mensuração esplênica pelo ultra-som Doppler (US Doppler, a falta de valores biométricos e dopplervelocimétricos dificultam a avaliação deste órgão e de suas características hemodinâmicas. OBJETIVO: Estabelecer padrões biométricos e hemodinâmicos por US-Doppler em indivíduos adultos sadios. MATERIAIS E MÉTODOS: Estudo prospectivo de 44 indivíduos sadios, sendo 19 do sexo masculino e 25 do sexo feminino, na faixa etária de 23 a 60 anos (37,4 ± 9,6. Morfometria (US modo-B: baço: eixos longitudinal (L, transversal (T e ântero-posterior (AP; diâmetro da artéria esplênica (DAE e diâmetro da veia esplênica (DVE. Índices morfométricos do baço: uniplanar (IBU, biplanar (IBB e volume esplênico (VE. Dopplervelocimetria (US Doppler: a artéria esplênica: velocidade de pico sistólico (VPS, média das velocidades máximas de fluxo (TAMax; índices de impedância vascular: índice de resistividade (IR; índice de pulsatilidade (IP; b veia esplênica: média das velocidades máximas de fluxo (TAMax. RESULTADOS: Morfometria: L = 9,3 ± 1,3 cm; T= 3,9 ± 0,7 cm; AP = 8,4 ± 1,2 cm; DAE = 0,3 ± 0,07 cm; DVE: 0,5 ± 0,12 cm. Índices morfométricos do baço: IBU = 33,5 ± 9,9; IBB = 36,7 ± 10,3; VE = 164,3 ± 62,9 cm³. Dopplervelocimetria: a artéria esplênica: VPS = 59,8 ± 23,6 cm/s; TAMax = 40,2 ± 15,9 cm/s; IP = 0,86 ± 0,30; IR = 0,55 ± 0,09; b veia esplênica: TAMax = 16,8 ± 8,3 cm/s. CONCLUSÃO: Relato de valores biométricos e dopplervelocimétricos do baço em indivíduos sadios.BACKGROUND: The diversity of existing techniques for the measurement of the spleen using Doppler ultrasound (Doppler-US as well as the lack of biometrical and Doppler velocimetry reference values make the evaluation of this organ and its hemodynamics quite difficult. OBJECTIVES: To establish biometrical and hemodynamics Doppler-US standard values for healthy adult individuals. MATERIALS AND METHODS

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... can be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ... is full when the scan begins. top of page What does the equipment look like? Ultrasound scanners consist ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Ultrasound examinations can help to diagnose a ... the scan begins. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  19. WE-B-210-02: The Advent of Ultrafast Imaging in Biomedical Ultrasound

    International Nuclear Information System (INIS)

    Tanter, M.

    2015-01-01

    In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented

  20. WE-B-210-02: The Advent of Ultrafast Imaging in Biomedical Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Tanter, M. [Laboratoire Ondes et Acoustique (France)

    2015-06-15

    In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented

  1. The Effectiveness of Real-Time Feedback with an Audible Pulse: A Preliminary Study in Renal Doppler Ultrasonography.

    Directory of Open Access Journals (Sweden)

    Min Hee Lee

    Full Text Available The effectiveness of real-time feedback using an audible pulse in renal Doppler ultrasonography was evaluated.This study was approved by the institutional review board of our hospital. Written informed consent was provided by all volunteers at enrollment. The 26 healthy volunteers enrolled in this study underwent Doppler ultrasound of both kidneys using audible and inaudible pulses in randomized order and at 1-week intervals. Doppler waveforms were obtained at the interlobar or arcuate arteries using a 2-mm Doppler gate. Each session was considered complete when reproducible waveforms were obtained for 5 s in three predefined regions of the kidney. The scan times needed to obtain waveforms of the right and left kidneys were recorded separately. Measurements were compared using a paired t-test and a two-sample Wilcoxon rank-sum test.The total recorded Doppler sonography scan time for each kidney ranged from 33 to 146 s. The mean scan time was 56.83 s (right, 58.19 s; left, 55.46 s in the audible session and 72.58 s (right, 72.08 s; left, 73.08 s in the inaudible session. The scan times were significantly shorter in the audible than inaudible session (p<0.001, whereas the difference in the scan times between the right and left kidneys was not significant. The order of the sessions had no effect on the total scan time.Real-time feedback using an audible pulse may encourage patient cooperation during breath-holding and can shorten the time needed to perform Doppler ultrasonography.

  2. Trauma Ultrasound.

    Science.gov (United States)

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Prachanukool, Thidathit; Sricharoen, Pungkava; Saksobhavivat, Nitima; Kaewlai, Rathachai

    2015-10-01

    Ultrasound plays a pivotal role in the evaluation of acute trauma patients through the use of multi-site scanning encompassing abdominal, cardiothoracic, vascular and skeletal scans. In a high-speed polytrauma setting, because exsanguinations are the primary cause of trauma morbidity and mortality, ultrasound is used for quick and accurate detection of hemorrhages in the pericardial, pleural, and peritoneal cavities during the primary Advanced Trauma Life Support (ATLS) survey. Volume status can be assessed non-invasively with ultrasound of the inferior vena cava (IVC), which is a useful tool in the initial phase and follow-up evaluations. Pneumothorax can also be quickly detected with ultrasound. During the secondary survey and in patients sustaining low-speed or localized trauma, ultrasound can be used to help detect abdominal organ injuries. This is particularly helpful in patients in whom hemoperitoneum is not identified on an initial scan because findings of organ injuries will expedite the next test, often computed tomography (CT). Moreover, ultrasound can assist in detection of fractures easily obscured on radiography, such as rib and sternal fractures. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Endoscopic Doppler ultrasound for measurement of azygos blood flow. Validation against thermodilution and assessment of pharmacological effects of terlipressin in portal hypertension

    DEFF Research Database (Denmark)

    Hansen, Erik Feldager; Bendtsen, Flemming; Brinch, K

    2001-01-01

    administration of terlipressin, the azygos blood flow, as measured by EUS Doppler, decreased significantly by 23% from 915 to 704 ml/min (P = 0.014) and the portal venous flow decreased by 28% from 1170 to 789 ml/min (P = 0.03). No effects of placebo were detected. CONCLUSIONS: These results show that EUS...... measurement of the azygos blood flow correlate strongly to the measurements by the thermodilution technique, and EUS is moreover well tolerated by the patients. The method is applicable for monitoring pharmacological effects on the superior porto-systemic collateral circulation and portal venous flow...

  4. Ultrasonography and color Doppler in juvenile idiopathic arthritis: diagnosis and follow-up of ultrasound-guided steroid injection in the wrist region. A descriptive interventional study

    Directory of Open Access Journals (Sweden)

    Laurell Louise

    2012-04-01

    Full Text Available Abstract Background The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA, and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US with Doppler in diagnosis of synovitis, guidance of steroid injections, and follow-up examinations of the wrist in JIA. Methods In 11 patients (median age 12.5 years, range 2-16, 15 wrists with clinically active arthritis were assessed clinically by US and color Doppler (Logiq 9, GE, 16-4 MHz linear transducer prior to and 1 and 4 weeks after US-guided steroid injection. Results US detected synovitis in the radio-carpal joints, the midcarpal joints, and the tendon sheaths in 87%, 53% and 33% of the wrists, respectively. Multiple compartments were involved in 67%. US-guidance allowed accurate placement of steroid in all 21 injected compartments, with a low rate of subcutaneous atrophy. Synovial hypertrophy was normalized in 86% of the wrists, hyperemia in 91%, and clinically active arthritis in 80%. Conclusions US enabled detection of synovial inflammation in compartments that are difficult to evaluate clinically and exact guidance of injections, and it was valuable for follow-up examinations. Normalization of synovitis was achieved in most cases, which supports the notion that US is an important tool in management of wrist involvement in JIA.

  5. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening...

  6. PREDICTION OF FETAL DISTRESS AND POOR OUTCOME OF PREGNANCY BEYOND 40 WEEKS USING DOPPLER ULTRASOUND COMPARED WITH FETAL HEART RATE MONITORING WITH NST

    Directory of Open Access Journals (Sweden)

    Supriya

    2015-06-01

    Full Text Available OBJECTIVES: Postdate pregnancy is the most common indication for Antepartum . F etal heart rate testing because of its increased perinatal morbidity and perinatal mortality. Complications are stillbirth , meconium aspiration , asphyxia , and the dysmaturity syndrome , is increased in post - term pregnancies. The most recent ACOG review of the subject of "post - term" pregnancy cites estimates of 3 - 14 % of all pregna n cies . MATERIALS AND METHODS: 55 patients with pregnancy beyond 40 weeks attending antenatal out - patient department of the Rajiv Gandhi medical college in the period between October 2014 to March 2015 were included. In present study , patients were monitored with twice weekly NST and once a week Doppler. In those with either NST nonreactive or Doppler abnormal , induction was done. Cases with normal results were monitored till 42 weeks when routine induction was done . RESULTS: A reactive non stress test in prolonged pregnancy has good negative predictive value – i.e. adverse outcomes are unlikely to occur in the setting of a reactive non - stress test – but that the positive predictive values are low . W eekly measurement of Doppler waveforms from umbilical artery (PI p=0.02 for Apgar <7 at 5 min , p=0.02 NICU admissions , p=0.003 for meconium staining of amniotic fluid and S/d ratio p=0.02 for Apgar <7 at 5 min , p=0.04 for NICU admission and biweekly NST(p=0.005 for Apgar <7 at 5 min , p=0.0219 for NICU admission , p=0.0039 for meconium staining of amniotic fluid appears to be reliable method of establishing fetal health in pregnancy beyond 40 weeks. CONCLUSION: The most sensitive tests to assess the risks to the fetus of prolonged pregnancy app ear to be combinations of fetal heart rate monitoring with NST combined with umbilical PI and S/D ratio. Reactive NST is reassuring and indicates fetal wellbeing, but non - reactive NST alone cannot be taken as an indicator of fetal jeopardy. Although individual randomized trials

  7. Quantification of colour Doppler activity in the wrist in patients with rheumatoid arthritis--the reliability of different methods for image selection and evaluation

    DEFF Research Database (Denmark)

    Ellegaard, K; Torp-Pedersen, S; Lund, Hans

    2008-01-01

    measurements in the wrist of patients with rheumatoid arthritis (RA) using different selection and quantification methods. MATERIALS AND METHODS: 14 patients with RA had their wrist scanned twice by the same investigator with an interval of 30 minutes. The images for analysis were selected either......PURPOSE: The amount of colour Doppler activity in the inflamed synovium is used to quantify inflammatory activity. The measurements may vary due to image selection, quantification method, and point in cardiac cycle. This study investigated the test-retest reliability of ultrasound colour Doppler...

  8. Quantification of colour Doppler activity in the wrist in patients with rheumatoid arthritis - the reliability of different methods for image selection and evaluation

    DEFF Research Database (Denmark)

    Ellegaard, K.; Torp-Pedersen, S.; Lund, H.

    2008-01-01

    measurements in the wrist of patients with rheumatoid arthritis (RA) using different selection and quantification methods. Materials and Methods: 14 patients with RA had their wrist scanned twice by the same investigator with an interval of 30 Minutes, The images for analysis were selected either......Purpose: The amount Of colour Doppler activity in the inflamed synovium is used to quantity inflammatory activity. The measurements may vary due to image selection, quantification method, and point in cardiac cycle. This study investigated the test-retest reliability Of ultrasound colour Doppler...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  10. Appendicular Mucocele Ultrasound Scan and TC: findings indicative of malignant ethiology; Ecografia y TC del mucocele apendicular: hallazgos que sugieren etiologia maligna

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, E.; Ripolles, T.; Martinez, M. J.; Delgado, F.; Agramunt, M.

    2003-07-01

    To describe appendicular mucocele ultrasound scan and computerized tomography (CT) findings, evaluating signs that help in predicting whether or not they are malignant in nature. Clinical and radiological findings of 17 patients in our hospital diagnosed with appendicular mucocele during the last 10 years (six cystadenocarcinomas, eight mucus retention cysts, two cyst adenoma and 1 villus adenoma). The ultrasound scan showed cystic masses in the theoretical location of the appendix, with layered structure in the wall, and with variable internal echogenicity. Seven cases exhibited parietal calcification. The CT showed cystic tumors of low attenuation in the pericecal area with parietal enhancement bands, being nodular in four cases (three cyst adenocarcinomas and a villus adenoma). None of the cyst adenocarcinomas presented calcified walls. In four patients, peritoneal pseudomyxoma was observed (three cyst adenocarcinomas and one mucus retention cyst). Appendicular mucoceles present some characteristic echographic and CT findings. The CT image of a nodular enhancement in the mucocele wall is one finding that suggests a malignant nature. The absence of parietal calcium and existence of associated peritoneal pseudomyxoma also suggest malignancy through both signs can also appear in benign mucoceles. (Author) 11 refs.

  11. Ultrasonography and color Doppler in juvenile idiopathic arthritis: diagnosis and follow-up of ultrasound-guided steroid injection in the ankle region. A descriptive interventional study

    Directory of Open Access Journals (Sweden)

    Boesen Mikael

    2011-01-01

    Full Text Available Abstract Background The ankle region is frequently involved in juvenile idiopathic arthritis (JIA but difficult to examine clinically due to its anatomical complexity. The aim of the study was to evaluate the role of ultrasonography (US of the ankle and midfoot (ankle region in JIA. Doppler-US detected synovial hypertrophy, effusion and hyperemia and US was used for guidance of steroid injection and to assess treatment efficacy. Methods Forty swollen ankles regions were studied in 30 patients (median age 6.5 years, range 1-16 years with JIA. All patients were assessed clinically, by US (synovial hypertrophy, effusion and by color Doppler (synovial hyperemia before and 4 weeks after US-guided steroid injection. Results US detected 121 compartments with active disease (joints, tendon sheaths and 1 ganglion cyst. Multiple compartments were involved in 80% of the ankle regions. The talo-crural joint, posterior subtalar joint, midfoot joints and tendon sheaths were affected in 78%, 65%, 30% and 55% respectively. Fifty active tendon sheaths were detected, and multiple tendons were involved in 12 of the ankles. US-guidance allowed accurate placement of the corticosteroid in all 85 injected compartments, with a low rate of subcutaneous atrophy (4,7%. Normalization or regression of synovial hypertrophy was obtained in 89%, and normalization of synovial hyperemia in 89%. Clinical resolution of active arthritis was noted in 72% of the ankles. Conclusions US enabled exact anatomical location of synovial inflammation in the ankle region of JIA patients. The talo-crural joint was not always involved. Disease was frequently found in compartments difficult to evaluate clinically. US enabled exact guidance of steroid injections, gave a low rate of subcutaneous atrophy and was proved valuable for follow-up examinations. Normalization or regression of synovial hypertrophy and hyperemia was achieved in most cases, which supports the notion that US is an important

  12. Is the third trimester repeat ultrasound scan for placental localisation needed if the placenta is low lying but clear of the os at the mid-trimester morphology scan?

    Science.gov (United States)

    Kapoor, Shveta; Thomas, Joseph T; Petersen, Scott G; Gardener, Glenn J

    2014-10-01

    It is unclear whether women with a low-lying placenta (not overlapping the internal cervical os) at the mid-trimester scan need follow-up. The aim of the study was to determine the rate of placenta praevia, vasa praevia and cord prolapse in the third trimester in this cohort of women. A retrospective cohort study of women with a documented low-lying placenta (os) at the mid-trimester morphology ultrasound scan was done. A composite outcome of rate of placenta praevia, vasa praevia or cord prolapse at term was evaluated. Multivariate analysis was performed to investigate the variables influencing the composite outcome. In addition, a meta-analysis of methodologically similar studies was performed to investigate the effect of the placenta to os distance at the mid-trimester scan on the rate of placenta praevia at term. One hundred and eighty-one women with a low-lying placenta not overlapping the os at mid-trimester scan were identified. The composite outcome was documented in 20 (11.0%) women, including placenta praevia in 15 (8.3%). Based on multivariate analysis, multiparity, distance from os os distance at mid-trimester. Our study supports the recommendation to follow up all women with a placenta lying os at mid-trimester. © 2014 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  13. Ablation of high intensity focused ultrasound combined with SonoVue on rabbit VX2 liver tumors: assessment with conventional gray-scale US, conventional color/power Doppler US, contrast-enhanced color Doppler US, and contrast-enhanced pulse-inversion harmonic US.

    Science.gov (United States)

    Luo, Wen; Zhou, Xiaodong; He, Guangbin; Li, Qiuyang; Zheng, Xiaoying; Fan, Zhiyong; Liu, Qing; Yu, Ming; Han, Zenghui; Zhang, Jun; Qian, Yunqiu

    2008-10-01

    We investigated effects of high intensity focused ultrasound (HIFU) combined with contrast agent SonoVue on rabbit VX2 liver tumors by using conventional gray-scale ultrasonography (US), color/power Doppler (CD/PD) US, contrast-enhanced color Doppler (CE CD) US, and contrast-enhanced pulse-inversion harmonic (CE PIH) US. Fourteen days after implantation of VX2 tumors in livers of 50 rabbits, animals were randomly separated into two groups. Based on principles of HIFU, the volume of the tumor was divided into several parallel "planes" to be ablated. Before ablation on each "plane," 0.2 mL SonoVue was injected in bolus via ear veins of rabbits in group II and normal saline solution was administrated in group I. Conventional gray-scale US, CD US, PD US, CE CD US, and CE PIH US were performed before and after ablation. Twenty-three surviving rabbits in each group underwent HIFU ablation. Conventional gray-scale US showed ablated areas diffusely hyperechoic. On CE PIH US, coagulated areas presented perfusion defect. Both conventional gray-scale US and CE PIH US showed the ablated volume in group II was larger than that in group I. CD US and PD US demonstrated residual vessels in periphery ablated areas in group I, but no residual vessels in group II. CE CD US and CE PIH US depicted less residual vessels in periphery ablated areas in group II than that in group I. By enlarging ablated volume of tissue and reducing residual vessels, effects of HIFU ablation on rabbit VX2 liver tumors were enhanced by contrast agent SonoVue.

  14. Ultrasound biomicroscopy of the anterior segment.

    Science.gov (United States)

    Liebmann, J M; Ritch, R

    1996-08-01

    New imaging technologies are revolutionizing the understanding and treatment of a wide variety of ocular disorders. Confocal scanning laser ophthalmoscopy, ultrasound biomicroscopy, confocal scanning laser polarimetry, color doppler imaging of blood flow, and optical coherence tomography are providing important information regarding disease pathophysiology, diagnosis, progression, and treatment. High frequency (50 MHz), high resolution ultrasound biomicroscopy of the anterior segment was obtained in a wide variety of disorders of the anterior segment. Tissue resolution is approximately 50 microns and the penetration depth is 5 mm. Ultrasound biomicroscopy is capable of imaging the comea, iris, anterior chamber, anterior chamber angle, posterior chamber, and ciliary body with great detail. The structures surrounding the posterior chamber, previously hidden from clinical observation, can be imaged and their normal anatomic relationships assessed. The various forms of angle closure glaucoma, such as pupillary block and plateau iris configuration, can be differentiated. The concave iris found in pigment dispersion and its response to treatment can be assessed. Visualization of anterior segment anatomy in eyes with opaque media is possible. Ultrasound biomicroscopy assists in the management of eyes with disorders of the anterior segment. Future applications of this technology will yield important information regarding accommodation, normal ocular physiology and disease pathophysiology.

  15. Avaliação da maturação das fístulas arteriovenosas para hemodiálise pelo eco-Doppler colorido Evaluation of hemodialysis arteriovenous fistula maturation by color-flow Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Jeferson Freitas Toregeani

    2008-09-01

    Full Text Available CONTEXTO: Quando se confecciona uma fístula arteriovenosa para hemodiálise (FAVH autógena, é necessário que se aguarde a dilatação da veia em questão e o desenvolvimento de volume de fluxo mínimo, fenômeno chamado de maturação. Ainda hoje se discute qual o tempo necessário para ocorrer essa maturação. OBJETIVO: Avaliar a maturação de FAVH utilizando-se critérios ecográficos. MÉTODO: Entre maio de 2004 e 2005, 40 pacientes foram selecionados prospectivamente, sendo 23 homens (57,5%, com média de idade de 17,5±51,3 anos, com indicação de confecção de uma FAVH. Utilizou-se o aparelho Logic III® com transdutor de 10 MHz para a avaliação no pré-operatório e nos 7º, 14º, 21º e 28º dias de pós-operatório. Os critérios para a maturação após a cirurgia foram: veia com diâmetro médio maior que 4 mm e volume de fluxo maior que 400 mL/min. RESULTADOS: O diâmetro médio pré-operatório foi de 3,24±1,43 e 3,71±1,37 mm para fístulas de punho e de cotovelo, respectivamente. O diâmetro final foi de 5,01±0,87 mm para as FAVH de punho (p = 0,006 e de 6,15±1,16 mm para as FAVH de cotovelo (p = 0,95. O volume de fluxo no 7º dia pós-operatório foi de 493,63±257,49 mL/min e 976,33±332,90 mL/min para as FAVH de punho e cotovelo, respectivamente. Ao final do estudo, foi calculado o valor de 556,81±288,42 mL/min nas FAVH de punho (p BACKGROUND: When a hemodialysis arteriovenous fistula (HAVF is created, it is important to wait for venous dilatation and volume flow increase through the HAVF, a phenomenon called maturation. There is still some controversy as to the exact time required for this maturation to occur. OBJECTIVE: To evaluate the time required for HAVF maturation using ultrasound criteria. METHOD: From May 2004 through May 2005, 40 patients were prospectively selected. The sample was comprised of 23 men (57.5 %, mean age of 51.3±17.5 years, with indication of HAVF creation. Logic III® ultrasound with 10

  16. Syndrome of transient headache and neurological deficits with cerebrospinal fluid lymphocytosis (HaNDL) in a patient with confusional symptoms, diffuse EEG abnormalities, and bilateral vasospasm in transcranial Doppler ultrasound: A case report and literature review.

    Science.gov (United States)

    Hidalgo de la Cruz, M; Domínguez Rubio, R; Luque Buzo, E; Díaz Otero, F; Vázquez Alén, P; Orcajo Rincón, J; Prieto Montalvo, J; Contreras Chicote, A; Grandas Pérez, F

    2017-04-17

    HaNDL syndrome (transient headache and neurological deficits with cerebrospinal fluid lymphocytosis) is characterised by one or more episodes of headache and transient neurological deficits associated with cerebrospinal fluid lymphocytosis. To date, few cases of HaNDL manifesting with confusional symptoms have been described. Likewise, very few patients with HaNDL and confusional symptoms have been evaluated with transcranial Doppler ultrasound (TCD). TCD data from patients with focal involvement reveal changes consistent with vasomotor alterations. We present the case of a 42-year-old man who experienced headache and confusional symptoms and displayed pleocytosis, diffuse slow activity on EEG, increased blood flow velocity in both middle cerebral arteries on TCD, and single-photon emission computed tomography (SPECT) findings suggestive of diffuse involvement, especially in the left hemisphere. To our knowledge, this is the first description of a patient with HaNDL, confusional symptoms, diffuse slow activity on EEG, and increased blood flow velocity in TCD. Our findings suggest a relationship between cerebral vasomotor changes and the pathophysiology of HaNDL. TCD may be a useful tool for early diagnosis of HaNDL. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Cerebral laterality for language is related to adult salivary testosterone levels but not digit ratio (2D:4D) in men: A functional transcranial Doppler ultrasound study.

    Science.gov (United States)

    Papadatou-Pastou, Marietta; Martin, Maryanne

    2017-03-01

    The adequacy of three competing theories of hormonal effects on cerebral laterality are compared using functional transcranial Doppler sonography (fTCD). Thirty-three adult males participated in the study (21 left-handers). Cerebral lateralization was measured by fTCD using an extensively validated word generation task. Adult salivary testosterone (T) and cortisol (C) concentrations were measured by luminescence immunoassay and prenatal T exposure was indirectly estimated by the somatic marker of 2nd to 4th digit length ratio (2D:4D). A significant quadratic relationship between degree of cerebral laterality for language and adult T concentrations was observed, with enhanced T levels for strong left hemisphere dominance and strong right hemisphere dominance. No systematic effects on laterality were found for cortisol or 2D:4D. Findings suggest that higher levels of T are associated with a relatively attenuated degree of interhemispheric sharing of linguistic information, providing support for the callosal and the sexual differentiation hypotheses rather than the Geschwind, Behan and Galaburda (GBG) hypothesis. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Adaptive Spectral Doppler Estimation

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-01-01

    . The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to pro- vide good spectral resolution and contrast even when the ob- servation window is very short. The 2 adaptive techniques are tested......In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence...... and compared with the averaged periodogram (Welch’s method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set...

  19. The significance of inadequate transcranial Doppler studies in children with sickle cell disease.

    Directory of Open Access Journals (Sweden)

    Simon Greenwood

    Full Text Available Sickle cell disease (SCD is a common cause of cerebrovascular disease in childhood. Primary stroke prevention is effective using transcranial Doppler (TCD scans to measure intracranial blood velocities, and regular blood transfusions or hydroxycarbamide when these are abnormal. Inadequate TCD scans occur when it is not possible to measure velocities in all the main arteries. We have investigated the prevalence and significance of this in a retrospective audit of 3915 TCD scans in 1191 children, performed between 2008 and 2015. 79% scans were normal, 6.4% conditional, 2.8% abnormal and 12% inadequate. 21.6% of 1191 patients had an inadequate scan at least once. The median age of first inadequate scan was 3.3 years (0.7-19.4, with a U-shaped frequency distribution with age: 28% aged 2-3 years, 3.5% age 10 years, 25% age 16 years. In young children reduced compliance was the main reason for inadequate TCDs, whereas in older children it was due to a poor temporal ultrasound window. The prevalence of inadequate TCD was 8% in the main Vascular Laboratory at King's College Hospital and significantly higher at 16% in the outreach clinics (P<0.0001, probably due to the use of a portable ultrasound machine. Inadequate TCD scans were not associated with underlying cerebrovascular disease.

  20. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  2. Scanning Ultrasound (SUS Causes No Changes to Neuronal Excitability and Prevents Age-Related Reductions in Hippocampal CA1 Dendritic Structure in Wild-Type Mice.

    Directory of Open Access Journals (Sweden)

    Robert John Hatch

    Full Text Available Scanning ultrasound (SUS is a noninvasive approach that has recently been shown to ameliorate histopathological changes and restore memory functions in an Alzheimer's disease mouse model. Although no overt neuronal damage was reported, the short- and long-term effects of SUS on neuronal excitability and dendritic tree morphology had not been investigated. To address this, we performed patch-clamp recordings from hippocampal CA1 pyramidal neurons in wild-type mice 2 and 24 hours after a single SUS treatment, and one week and 3 months after six weekly SUS treatments, including sham treatments as controls. In both treatment regimes, no changes in CA1 neuronal excitability were observed in SUS-treated neurons when compared to sham-treated neurons at any time-point. For the multiple treatment groups, we also determined the dendritic morphology and spine densities of the neurons from which we had recorded. The apical trees of sham-treated neurons were reduced at the 3 month time-point when compared to one week; however, surprisingly, no longitudinal change was detected in the apical dendritic trees of SUS-treated neurons. In contrast, the length and complexity of the basal dendritic trees were not affected by SUS treatment at either time-point. The apical dendritic spine densities were reduced, independent of the treatment group, at 3 months compared to one week. Collectively, these data suggest that ultrasound can be employed to prevent an age-associated loss of dendritic structure without impairing neuronal excitability.

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... extract sample cells from an abnormal area for laboratory testing. Ultrasound may also be used to guide the insertion of a catheter or other drainage device and helps assure safe and accurate placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound ...

  4. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2011-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  5. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2011-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some guid...

  6. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some guid...

  7. Ultralyd farve-Doppler-undersøgelse af arteria carotis. Prospektiv sammenligning med arteriografi

    DEFF Research Database (Denmark)

    Sillesen, H H; Just, S R; Hansen, Linda

    1994-01-01

    Eleven hundred and thirty-eight patients suspected of carotid artery disease were examined prospectively by ultrasound-Doppler. In 39 cases, intra-arterial digital subtraction arteriography was performed as well as well and compared to ultrasound Doppler examination. The overall accuracy was 80% ...

  8. Doppler Sonographic Evaluation of Venogenic Extremity Swellings ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... potentially lead to many complications including life-threatening pulmonary arterial thrombosis. Screening and confirmation ... and exclusion of acute lower extremity DVT. Duplex ultrasound is considered as the ... this study evaluates the role of Doppler sonography in the clinical management of suspected.

  9. Doppler sonographic evaluation of venogenic extremity swellings ...

    African Journals Online (AJOL)

    Doppler ultrasound is very useful in the evaluation of extremity DVT. All clinically suspected cases should be evaluated with this modality due to limited sensitivity of clinical evaluation in the diagnosis of DVT. Further correlative studies in comparison to venography and hematologic indices are also recommended.

  10. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  11. Temporal summation of pain and ultrasound Doppler activity as predictors of treatment response in patients with rheumatoid arthritis: protocol for the Frederiksberg hospitals Rheumatoid Arthritis, pain assessment and Medical Evaluation (FRAME-cohort) study.

    Science.gov (United States)

    Christensen, Anton Wulf; Rifbjerg-Madsen, Signe; Christensen, Robin; Amris, Kirstine; Taylor, Peter C; Locht, Henning; Ellegaard, Karen; Torp-Pedersen, Søren; Jespersen, Anders; Bartels, Else Marie; Danneskiold-Samsøe, Bente; Bliddal, Henning

    2014-01-03

    Chronic pain is common in rheumatoid arthritis (RA) and may still persist despite regression of objective signs of inflammation. This has led researchers to hypothesise that central pain sensitisation may play a role in the generation of chronic pain in RA. Application of the disease activity score DAS28 can classify some patients with active RA solely based on a high tender joint count and poor patient global health score. In such cases, intensified treatment with anti-inflammatory drugs would be expected to yield poorer results than in cases with DAS28 elevation due to a high score for swollen joints and C reactive protein (CRP). Evaluation of central pain sensitisation in patients with few inflammatory indices may be a predictive tool regarding the effect of anti-inflammatory treatment. Computerised pneumatic cuff pressure algometry (CPA) is a method for assessing temporal summation (ie, degree of central sensitisation). The main objective of this study was to examine the prognostic values of pressure pain-induced temporal summation, ultrasound Doppler activity and the interaction between them in relation to treatment response (DAS28-CRP change) in patients with RA initiating any anti-inflammatory therapy. 120 participants ≥18 years of age will be recruited. Furthermore, they must be either (1) diagnosed with RA, untreated with disease-modifying antirheumatic drugs for at least 6 months and about to initiate disease-modifying antirheumatic drug treatment or (2) about to begin or switch treatment with any biological drug for their RA. Data (clinical, imaging, blood samples, patient reported outcomes and CPA measurements) will be collected from each participant at baseline and after 4 months of anti-inflammatory treatment. This study has been approved by the ethics committee for the Copenhagen region (H-4-2013-007). Dissemination will occur through presentations and publication in international peer-reviewed journals.

  12. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of Echovist-200 and Echovist-300, timing of the Valsalva maneuver, and general recommendations for the performance of the test.

    Science.gov (United States)

    Droste, Dirk W; Jekentaite, Ruta; Stypmann, Jörg; Grude, Matthias; Hansberg, Tjark; Ritter, Martin; Nabavi, Darius; Nam, Eun-Mi; Dittrich, Ralf; Wichter, Thomas; Ringelstein, E Bernd

    2002-01-01

    Cardiac right-to-left shunts (RLS) can be identified by transesophageal echocardiography (TEE) as well as by transcranial Doppler ultrasound (TCD) using contrast agents, such as Echovist-200 or Echovist-300 in conjunction with a Valsalva maneuver (VM) as provocation procedure. Both Echovist preparations are in use. Currently, the appropriate timing of the VM is still under debate. Sixty-four patients were investigated by both TEE and bilateral TCD of the middle cerebral arteries. The following protocol was applied in a randomized way: (1) no VM, (2) VM for 5 s starting with the beginning of Echovist-300 injection, (3) VM for 5 s starting 5 s after the beginning of Echovist-300 injection, (4) VM for 5 s starting 10 s after the beginning of Echovist-300 injection, and (5) VM for 5 s starting 5 s after the beginning of Echovist-200 injection. In 27 patients, an RLS was demonstrated by both TEE and contrast TCD (shunt-positive). Twenty-two patients were negative in both investigations, no patient was positive on TEE but negative on TCD, 15 patients were only positive on at least one TCD investigation but negative on TEE. Tests 3 and 5 were the most appropriate ones; test 3 was slightly superior to test 5. TCD using Echovist-300 or Echovist-200 is a sensitive method to identify TEE-proven cardiac RLS. To achieve the best diagnostic accuracy, the VM should be performed for a duration of 5 s starting at 5 s following the beginning of contrast injection. Copyright 2002 S. Karger AG, Basel

  13. Use of ultrasound imaging for the diagnosis of abnormal uterine bleeding in the bonnet macaque ( Macaca radiata).

    Science.gov (United States)

    Chaudhari, Uddhav K; Imran, M; Manjramkar, Dhananjay D; Metkari, Siddhanath M; Sable, Nilesh P; Gavhane, Dnyaneshwar S; Katkam, Rajendra R; Sachdeva, Geetanjali; Thakur, Meenakshi H; Kholkute, Sanjeeva D

    2017-02-01

    Ultrasound is a powerful, low-cost, non-invasive medical tool used by laboratory animal veterinarians for diagnostic imaging. Sonohysterography and transvaginal ultrasound are frequently used to assess uterine anomalies in women presenting with abnormal uterine bleeding (AUB). In the present study, we have evaluated the abdominal ultrasound of bonnet monkeys ( n = 8) showing spontaneous ovulatory ( n = 5) and anovulatory ( n = 3) AUB. The ovulatory ( n = 5) macaques showed cyclic AUB for 7-8 days. The anovulatory ( n = 3) macaques had irregular AUB with menstrual cycles of 40-45 days. The B-mode abdominal, colour Doppler and 3D ultrasound scans were performed during the proliferative phase of the menstrual cycle. Ultrasound examination revealed endometrial polyps in five macaques and endometrial hyperplasia in three animals. The width and length of endometrial polyps was around 0.5-1 cm (average 0.51 ± 0.23 cm × 0.96 ± 0.16 cm) with significant increase in endometrial thickness ( P uterine cavity and colour Doppler ultrasound showed increased vascularity in the endometrial polyps. Endometrial hyperplasia characteristically appeared as a thickened echogenic endometrium ( P < 0.0002). This study demonstrates the use of non-invasive ultrasound techniques in the diagnosis of AUB in macaques.

  14. The role of contrast-enhanced ultrasound (CEUS) in visualizing atherosclerotic carotid plaque vulnerability: Which injection protocol? Which scanning technique?

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto, E-mail: roberto.iezzi@rm.unicatt.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Petrone, Gianluigi [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Ferrante, Angela [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Lauriola, Libero [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Vincenzoni, Claudio [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Torre, Michele Fabio la [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Snider, Francesco [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Rindi, Guido [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2015-05-15

    Highlights: • CEUS is a safe and efficacious technique for the identification and characterization of carotid plaque. • CEUS represents a diagnostic tool for the management of patients with carotid plaque, particularly in asymptomatic patients. • Improved diagnostic performance is achieved with the injection of 4 mL bolus of contrast-medium. • Improved diagnostic performance is achieved with the use of Dynamic Imaging rather than late-phase imaging. - Abstract: Purpose: To correlate the degree of plaque vulnerability as determined by contrast-enhanced ultrasound (CEUS) with histological findings. Secondary objectives were to optimize the CEUS acquisition technique and image evaluation methods. Materials and methods: Fifty consecutive patients, either symptomatic and asymptomatic referring to our department in order to perform carotid endarterectomy (TEA), were enrolled. Each patient provided informed consent before undergoing CEUS. Ultrasound examination was performed using high-frequency (8–14 MHz) linear probe and a non-linear pulse inversion technique (mechanical index: 0.09–1.3). A double contrast media injection (Sonovue, 2 mL and 4 mL; Bracco, Italy) was performed. Two videotapes were recorded for every injection: early “dynamic” phase and late “flash” phase, performed with 6 high mechanical index impulses. Movies were quantitatively and qualitatively evaluated. Qualitative and quantitative evaluation were statistically compared to immunohistological diagnosis of vulnerable plaque, considered as gold standard. Results: Qualitative CEUS evaluation obtained high statistical results when compared to immunohistological results, with values of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of 94%, 68%, 87%, 85% and 86%, respectively, which became higher if considering only asymptomatic patient, with a NPV of 91%. Nevertheless, quantitative software evaluation proved less

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen is a safe, noninvasive test that uses sound waves to produce a clear picture of the ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  17. "Holy scan" or "picture of the baby?" Biomedicalization and stratification in the use of obstetric ultrasound in Rio de Janeiro.

    Science.gov (United States)

    Chazan, Lilian Krakowski; Faro, Livi F T

    2016-01-01

    Based on ethnographic studies conducted at public and private healthcare facilities in Rio de Janeiro, we argue that the dissemination of (bio)medicalization varies in accordance with the social stratum of the expectant mothers, thereby producing thoroughly distinct fetal and pregnant bodies, as well as different gestational processes. Starting from the basic premise that biomedicalization represents a transformation in the process of medicalization, characterized by the growing incorporation of technoscience into biomedicine, the observed universes displayed different stages in this transformation, consonant with the social stratification of the women who underwent the scans.

  18. The Lunula: An ultrasound imaging approach

    International Nuclear Information System (INIS)

    Choi, Soo Jung; Shin, Myung Jin; Kim, Sung Moon; Ahn, Joong Mo

    2001-01-01

    The lunula is the white, half-moon-shaped area seen on some, but not all nails. Usually the lunula is the topographic marker of the distal part of the nail matrix, and known to have the ability of nail production. Ultrasonographic imaging of the lunula has not been reported before. This study was undertaken to demonstrate normal ultrasonographic features of the lunula. Ultrasonographic examination of the lunula was performed in the right thumb of 20 healthy volunteers (10M, 10F, mean age 30, range 26-36 years) with a real-time, high-resolution ultrasound unit (Sequoia 512, Acuson, Mountain view, CA, USA) with 8-15 MHz linear transducers. Gray scale color, and special Doppler imagings were performed with longitudinal scanning. The lunula was not seen inspection in three of the 20 volunteers. The mean size of the lunula in the other 17 volumteen was 3.31 ± 1.24 mm (range 2-6.2 mm). Gray scale ultrasound imaging showed the lunula; ovoid shaped hypo-echoic zone in proximal fingernail in 18 of 20 volunteers (mean size, 6.74 ± 0.98 mm, range 5-8.8 mm). In two of 20 volunteers, the lunula was indistinct on gray scale ultrasound examination. However, all lunula were identifiable on color Doppler imaging by detecting vascularity within the lunula. Spectral wave pattern of the lunula was a bi-directional pulsatile wave. Peak velocity was within 5-15 m/sec (mean 8 m/sec). The lunula is identifiable on ultrasound examination as a hyper-vascular, ovoid shaped, hypo-echoic zone in proximal fingernail. This normal structure should not be misinterpreted as an abnormal sub-ungual lesion.

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  1. Vesico-ureteral reflux: diagnosis and staging with voiding color doppler US Preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Renato; Arena, Carmela; Pennisi, Francesco; Di Benedetto, Vincenzo; Politi, Guido; Di Benedetto, Aurelio

    2000-07-01

    Introduction: The aim of this study is to assess the accuracy of a new US examination: 'voiding color Doppler US ' in the early diagnosis and staging of vesico-ureteral reflux (VUR). The contrast agent US was SH U 508A (Levovist, Schering, Berlin), which produces a chromatic accentuation of the signals picked up by the color Doppler US. Eighteen patients (10 females, eight males) were recruited for the study. In two patients a second examination was performed for follow-up after a VUR conservative therapy. All patients were taken under examination for the evaluation of possible VUR. In all patients the voiding color Doppler US was followed by voiding cystourethrography (VCUG) and the data obtained were compared. Materials and methods: A total of 18 patients aged between 3 months and 10 years, were recruited for the study. The results of the examination were the following: urinary tract infections, follow-up of VUR after conservative or surgical therapy, miscellaneous indications. Voiding color Doppler US was performed, followed by a VCUG. The voiding color Doppler US consists in the trans-catheter introduction of a contrast agent SHU 508 A (Levovist, Schering, Ag. Berlin) into the bladder and a subsequent test with the color Doppler US to show or exclude the presence of reflux into the ureters and/or into the pyelo-caliceal cavity of the kidneys. After the introduction of the contrast agent US the ultrasound scanning of the bladder, the ureters and the pyelo-caliceal cavity was performed to examine the reflux degree. The ultrasonographic investigations were perfomed with AU 590 asyncronus US (Esaote Biomedica, Genova) with a 3.5 MHz convex probe. Results: After the trans-catheter introduction of the contrast agent US, vesico-ureteral reflux occured in 13 patients (77.2%). The reflux degree was also measured by means of ultrasound and was later confirmed by VCUG. The mean times of each examination were as follows: initial US, 10 min; catheterization, 8 min

  2. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties.

    Science.gov (United States)

    Cournane, S; Cannon, L; Browne, J E; Fagan, A J

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 µm Al(2)O(3) and 3 µm Al(2)O(3), were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s(-1), respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  3. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Cournane, S; Fagan, A J [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Cannon, L; Browne, J E [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Kevin' s Street, Dublin 8 (Ireland)

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 {mu}m Al{sub 2}O{sub 3} and 3 {mu}m Al{sub 2}O{sub 3}, were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s{sup -1}, respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  4. Ultrasound, color - normal umbilical cord (image)

    Science.gov (United States)

    ... is a normal color Doppler ultrasound of the umbilical cord performed at 30 weeks gestation. The cord is ... the cord, two arteries and one vein. The umbilical cord is connected to the placenta, located in the ...

  5. Diagnostik af arteriosklerose i arteria carotis ved hjaelp af ultralyd-Doppler. Metodebeskrivelse og prospektiv sammenligning med arteriografi

    DEFF Research Database (Denmark)

    Sillesen, H H; Just, S R; Hansen, L

    1991-01-01

    The ultrasound Doppler method for examination of the carotid artery is described. Out of a total of 370 patients examined with ultrasound Doppler for suspected arteriosclerosis in the carotid artery in 1988, 27 were also submitted to digital subtraction arteriography (DSA). The accuracy of the ul...

  6. Brain Surface Heating After Exposure to Ultrasound: An Analysis Using Thermography.

    Science.gov (United States)

    Schneider, Michal E; Lombardo, Paul

    2016-05-01

    Ultrasound is the imaging modality of choice to monitor brain pathologies in neonates after complicated deliveries. Animal studies have indicated that ultrasound may cause heating of brain tissues. To date, no study has explored brain surface heating by ultrasound during clinically relevant exposure. Hence, we investigated heating effects of B-mode and pulsed Doppler (PD) mode on ex vivo lamb brains using thermography. Five brains were scanned for 5 min in B-mode or for 3 min, 1 min, 30 s or 15 s in PD mode. Brain surface temperature was measured pre- and post-exposure using thermography. The highest mean temperature increase was recorded by B-mode (3.82 ± 0.43°C). All five PD exposure protocols were associated with surface temperature increases of 2.1-2.7°C. These outcomes highlight for the first time that B-mode ultrasound can contribute to brain surface heating during a routine cranial scan. Scan duration should be minimised whenever possible. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. Prevalence of defined ultrasound findings of unknown significance at the second trimester fetal anomaly scan and their association with adverse pregnancy outcomes: the Welsh study of mothers and babies population?based cohort

    OpenAIRE

    Hurt, Lisa; Wright, Melissa; Dunstan, Frank; Thomas, Susan; Brook, Fiona; Morris, Susan; Tucker, David; Wills, Marilyn Ann; Davies, Colin; John, Gareth; Fone, David; Paranjothy, Shantini

    2015-01-01

    Abstract Objective The aim of this article was to estimate the population prevalence of seven defined ultrasound findings of uncertain significance (?markers?) in the second trimester and the associated risk of adverse pregnancy outcomes. Method A prospective record?linked cohort study of 30?078 pregnant women who had second trimester anomaly scans between July 2008 and March 2011 in Wales was conducted. Results The prevalence of markers ranged from 43.7 per 1000 singleton pregnancies for car...

  8. Measurement of skull bone thickness for bone-anchored hearing aids: an experimental study comparing both a novel ultrasound system (SonoPointer) and computed tomographic scanning to mechanical measurements.

    Science.gov (United States)

    Federspil, Philipp A; Tretbar, Steffen H; Böhlen, Friederike H; Rohde, Stefan; Glaser, Simon; Plinkert, Peter K

    2010-04-01

    A-mode ultrasound scanning with coded signals allows bone thickness measurements at the site of bone-anchored hearing aid surgery as compared to computed tomographic scanning and mechanical measurements. Adequate bone thickness is a prerequisite for successful, long-lasting osseointegration of titanium fixtures for bone-anchored hearing aids. Computed tomography can be used to measure bone thickness but has several drawbacks. Bone thickness was measured at the site of bone-anchored hearing aids surgery in 28 formaldehyde-preserved human cadaver temporoparietal bones. Four blinded investigators used a hand-held, A-mode ultrasound system with direct coupling at 2.25 MHz transducer using coded signals (SonoPointer) and repeated the measurements twice. Comparisons were made with high-resolution computed tomographic scanning and mechanical micrometer caliper measurements. There was significant anatomical variation in the temporoparietal bones. Computed tomography was in good agreement with the mechanical reference. All specimens could be measured by the SonoPointer. The mean difference between the mechanical control and ultrasound scanning averaged for all measurements by all investigators was 0.3 mm (standard deviation, 1.2 mm). Trained ultrasound experts yielded better results (mean difference, 0.3 mm; standard deviation, 1.0 mm). Agreement was best for bone thickness up to 5 mm. Outliers occurred in bones thicker than 7.5 mm. The SonoPointer is a promising, noninvasive, hand-held tool for real-time measurement of bone thickness in bone-anchored hearing aid surgery, especially for children. Even disregarding the absolute thickness reading, the SonoPointer could be used to search intraoperatively for a local maximum of bone thickness.

  9. Ultrasound guided electrocoagulation in patients with chronic non-insertional Achilles tendinopathy

    DEFF Research Database (Denmark)

    Boesen, M Ilum; Torp-Pedersen, S; Koenig, M Juhl

    2006-01-01

    High resolution colour Doppler ultrasound shows intratendinous Doppler activity in patients with chronic Achilles tendinopathy. Treatment of this neovascularisation with sclerosing therapy seems to relieve the pain. However, the procedure often has to be repeated.......High resolution colour Doppler ultrasound shows intratendinous Doppler activity in patients with chronic Achilles tendinopathy. Treatment of this neovascularisation with sclerosing therapy seems to relieve the pain. However, the procedure often has to be repeated....

  10. Ultrasound contrast agents: An overview

    International Nuclear Information System (INIS)

    Cosgrove, David

    2006-01-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MI < 0.3) so that the microbubbles are not destroyed and scanning can continue in real time. The clinical roles of contrast enhanced ultrasound scanning are expanding rapidly. They are established in echocardiography to improve endocardial border detection and are being developed for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating

  11. Ultrasound contrast agents: an overview.

    Science.gov (United States)

    Cosgrove, David

    2006-12-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MI<0.3) so that the microbubbles are not destroyed and scanning can continue in real time. The clinical roles of contrast enhanced ultrasound scanning are expanding rapidly. They are established in echocardiography to improve endocardial border detection and are being developed for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating

  12. Stress fractures of the ankle malleoli diagnosed by ultrasound: a report of 6 cases

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, Stefano [CIM SA, Cabinet Imagerie Medicale, Geneve (Switzerland); Luong, Dien Hung [CIM SA, Cabinet Imagerie Medicale, Geneve (Switzerland); University of Montreal, Department of Physical Medicine and Rehabilitation, Montreal (Canada)

    2014-06-15

    To present the ultrasound appearance of stress fractures (SF) of the ankle malleoli. We present a retrospective review of 6 patients (4 women and 2 men, with an age range of 24-52 years, mean age of 39 years) in which ultrasound diagnosed, together with the clinical findings, an SF of the ankle malleoli. For all of these patients ultrasound was the first imaging technique applied because of a clinical suspicion of soft tissue injuries following excessive exertion. Patients were subsequently examined using standard radiographs and/or MRI. At ultrasound patients showed thickening of the periosteum in all patients, calcified bone callus was evident in 3 out of 6 patients. Cortical irregularities and subcutaneous oedema were found in all but one patient. Colour Doppler showed local hypervascular changes in all patients. Local compression with the transducers during real-time scanning increased pain in all cases. Ultrasound, together with the clinical findings, can diagnose an SF of the ankle malleoli. We suggest that sonologists should include malleolar SF in their differential diagnosis, particularly in the case of perimalleolar pain from over-solicitation. They must also include, as part of every ultrasound examination of the ankle, the evaluation of both malleoli and should be aware of the ultrasound appearance of malleolar SF. If the diagnosis remains uncertain, an MRI should be prescribed. (orig.)

  13. Stress fractures of the ankle malleoli diagnosed by ultrasound: a report of 6 cases

    International Nuclear Information System (INIS)

    Bianchi, Stefano; Luong, Dien Hung

    2014-01-01

    To present the ultrasound appearance of stress fractures (SF) of the ankle malleoli. We present a retrospective review of 6 patients (4 women and 2 men, with an age range of 24-52 years, mean age of 39 years) in which ultrasound diagnosed, together with the clinical findings, an SF of the ankle malleoli. For all of these patients ultrasound was the first imaging technique applied because of a clinical suspicion of soft tissue injuries following excessive exertion. Patients were subsequently examined using standard radiographs and/or MRI. At ultrasound patients showed thickening of the periosteum in all patients, calcified bone callus was evident in 3 out of 6 patients. Cortical irregularities and subcutaneous oedema were found in all but one patient. Colour Doppler showed local hypervascular changes in all patients. Local compression with the transducers during real-time scanning increased pain in all cases. Ultrasound, together with the clinical findings, can diagnose an SF of the ankle malleoli. We suggest that sonologists should include malleolar SF in their differential diagnosis, particularly in the case of perimalleolar pain from over-solicitation. They must also include, as part of every ultrasound examination of the ankle, the evaluation of both malleoli and should be aware of the ultrasound appearance of malleolar SF. If the diagnosis remains uncertain, an MRI should be prescribed. (orig.)

  14. Observer agreement of lower limb venous reflux assessed by duplex ultrasound scanning using manual and pneumatic cuff compression in patients with chronic venous disease and controls

    DEFF Research Database (Denmark)

    Broholm, R; Kreiner, S; Bækgaard, Niels

    2011-01-01

    The study aimed to evaluate observer agreement between two experienced ultrasound operators examining deep venous reflux assessed by duplex ultrasound (DU) using either manual or pneumatic cuff compression. In addition, the two methods were compared with each other with regard to immediate...

  15. Doppler flow patterns in pediatric pulmonary pathology

    International Nuclear Information System (INIS)

    Garcia, J.A.; Valdes, P.; Valls, E.; Alonso, I.; Ceres, L.

    1996-01-01

    To differentiate, in a number of pediatric lung diseases, a series of Doppler flow patterns according to their pulmonary or systemic origin, assessing the morphology of the spectral curve. We have reviewed the Doppler studies carried out in 22 patients with a variety of pulmonary pathologies, including several pulmonary abnormalities: three cases of sequestration, four cases of pulmonary vein drainage problems (one with no evidence of associated pulmonary abnormality, two with scimitar syndrome and one variant with accessory diaphragm), one case of cystic adenomatoid malformation, three cases of metastatic neoplastic lesion, one case of hydatid cyst and 10 cases of infections pathology and atelectasis, the underlying causes of which were unknown. We have found four basis patterns of pulmonary or systemic arterial and venous vascularization in ultrasonographic studies. We conclude that the use of Doppler ultrasound associated with standard ultrasonography is a very helpful tool in the initial diagnosis of pulmonary vascularization abnormalities. (Author)

  16. Maternal exposure to ambient air pollution and fetal growth in North-East Scotland: A population-based study using routine ultrasound scans.

    Science.gov (United States)

    Clemens, Tom; Turner, Steve; Dibben, Chris

    2017-10-01

    Maternal ambient air pollution exposure is associated with reduced birthweight. Few studies have examined the effect on growth in utero and none have examined the effect of exposure to particulates less than 2.5µm (PM 2.5 ) and possible effect modification by smoking status. Examine the effect of maternal exposure to ambient concentrations of PM 10 , PM 2.5 and nitrogen dioxide (NO 2 ) for in utero fetal growth, size at birth and effect modification by smoking status. Administratively acquired second and third trimester fetal measurements (bi-parietal diameter, femur length and abdominal circumference), birth outcomes (weight, crown heel length and occipito-frontal circumference) and maternal details were obtained from routine fetal ultrasound scans and maternity records (period 1994-2009). These were modelled against residential annual pollution concentrations (calendar year mean) adjusting for covariates and stratifying by smoking status. In the whole sample (n=13,775 pregnancies), exposure to PM 10 , PM 2.5 and NO 2 was associated with reductions in measurements at birth and biparietal diameter from late second trimester onwards. Among mothers who did not smoke at all during pregnancy (n=11,075), associations between biparietal diameter and pollution exposure remained significant but were insignificant among those who did smoke (n=2700). Femur length and abdominal circumference were not significantly associated with pollution exposure. Fetal growth is strongly associated with particulates exposure from later in second trimester onwards but the effect appears to be subsumed by smoking. Typical ambient exposures in this study were relatively low compared to other studies and given these results, it may be necessary to consider reducing recommended "safe" ambient air exposures. Copyright © 2017. Published by Elsevier Ltd.

  17. Ultrasound: Abdomen (For Parents)

    Science.gov (United States)

    ... bladder abdominal masses such as tumors, cysts, or abscesses abnormal fluid in the abdomen Abdominal ultrasounds can ... on this topic for: Parents Pyloric Stenosis Appendicitis CAT Scan: Abdomen X-Ray Exam: Abdomen View more ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  19. Skin Ultrasound in Kaposi Sarcoma.

    Science.gov (United States)

    Carrascosa, R; Alfageme, F; Roustán, G; Suarez, M D

    2016-05-01

    The use of ultrasound imaging has recently been increasing in numerous dermatologic diseases. This noninvasive technique provides additional details on the structure and vascularization of skin lesions. Kaposi sarcoma is a vascular tumor that typically arises in the skin and mucosas. It can spread to lymph nodes and internal organs. We performed B-mode and color Doppler ultrasound studies in 3 patients with a clinical diagnosis of Kaposi sarcoma confirmed by histological examination. We found differences in the ultrasound pattern between nodular and plaque lesions, in both B-mode and color Doppler. We believe that skin ultrasound imaging could be a useful technique for studying cutaneous Kaposi sarcoma, providing additional information on the structural and vascular characteristics of the lesion. Copyright © 2015 Elsevier España, S.L.U. y AEDV. All rights reserved.

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  1. Diagnostic efficacy of SonoVue, a second generation contrast agent, in the assessment of extracranial carotid or peripheral arteries using colour and spectral Doppler ultrasound: a multicentre study

    NARCIS (Netherlands)

    Sidhu, P. S.; Allan, P. L.; Cattin, F.; Cosgrove, D. O.; Davies, A. H.; Do, D. D.; Karakagil, S.; Langholz, J.; Legemate, D. A.; Martegani, A.; Llull, J.-B.; Pezzoli, C.; Spinazzi, A.

    2006-01-01

    The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with

  2. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  3. Serum YKL-40 and uterine artery Doppler – a prospective cohort study, with focus on preeclampsia and small-for-gestational-age

    DEFF Research Database (Denmark)

    Gybel-Brask, Dorte; Høgdall, Estrid; Johansen, Julia

    2014-01-01

    -week fetal growth examinations. Uterine artery Doppler was assessed and outcome was registered from medical records. MAIN OUTCOME MEASURES: Preeclampsia, hypertension, small-for-gestational age. RESULTS: Serum YKL-40 was associated with increasing maternal age (p ...OBJECTIVE: To test if serum YKL-40 is increased in women developing preeclampsia or small-for-gestational age fetuses. We also assessed the association between uterine artery pulsatility index, notching and serum YKL-40 levels. DESIGN: Prospective cohort study. SETTING: A primary referral unit...... for obstetric ultrasound. POPULATION: A total of 1214 unselected pregnant women enrolled at nuchal translucency examination between 11(+3) and 13(+6) weeks of gestation. METHODS: All women had ultrasound and blood sample collection at the nuchal translucency scan, a 20-week malformation scan and 25-week and 32...

  4. Decision Making with Ultrasound in Rheumatology

    NARCIS (Netherlands)

    M. van der Ven (Myrthe)

    2018-01-01

    markdownabstractThe _first aim_ of this thesis was to evaluate the added value of ultrasound in clinical decision making in patients with arthralgia, patients with psoriasis and monitoring RA patients. Our _second aim_ was to increase sensitivity of power Doppler ultrasound for MCP joints.

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  6. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  7. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    Energy Technology Data Exchange (ETDEWEB)

    Delgado Oliva, F., E-mail: frandelgol@hotmail.com; Arlandis Guzman, S.; Bonillo García, M.; Broseta Rico, E.; Boronat Tormo, F.

    2016-10-15

    Objectives: To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. Material and methods: A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4–20 ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Results: Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3 ± 7.01 years (95% CI, 63.75–64.70); mean total PSA was 8.9 ± 3.61 ng/mL (95% CI, 8.67–9.13) and the mean prostate volume was 56.2 ± 29 cc (95% CI, 54.2–58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16

  8. Spleen evaluation using contrast enhanced ultrasonography and Doppler in dogs with subclinical ehrlichiosis

    Directory of Open Access Journals (Sweden)

    M.C. Maronezi

    2015-12-01

    Full Text Available The aim of this study was to evaluate the splenic parenchyma of dogs with subclinical ehrlichiosis using Doppler and contrast-enhanced ultrasonography and provide reference values for this organ in affected animals. Seventeen dogs naturally infected with E. canis were selected for this study. Splenic parenchyma echotexture and echogenicity, size and borders were determined by ultrasound scan. The vascular indices of the splenic artery were determined by Doppler. SonoVue, at 0.1mL per animal, was used in microbubble contrast-enhanced ultrasonography to determine wash in, wash out and peak enhancement time in the splenic tissue. B-mode ultrasonography revealed splenomegaly with rounded borders, heterogeneous echotexture and mixed echogenicity. The vascular indices of the splenic artery were: systolic velocity of 22.59±8.07cm/s, diastolic velocity of 5.25±4.66cm/s and resistance index of 0.71±0.14; values not yet reported in Veterinary Medicine. Contrast-enhanced ultrasonography recorded wash in time of 5.31±0.7s, peak enhancement time of 18.56±2.90s and wash out time of 94.56±35.21s. The combination of conventional ultrasonography of the spleen and hemodynamic evaluation by Doppler and contrast-enhanced ultrasonography is important for the diagnosis of canine ehrlichiosis and could help monitor the clinical evolution of subclinical cases.

  9. FETAL DOPPLER VELOCIMETRY IN THE INTERNAL CAROTID AND UMBILICAL ARTERY DURING BRAXTON-HICKS CONTRACTIONS

    NARCIS (Netherlands)

    DIJKSTRA, K; AARNOUDSE, JG; Oosterhof, H.

    Using Doppler ultrasound, previous studies revealed a considerable increase in vascular resistance in the uteroplacental circulation during Braxton Hicks' contractions. Consequently, uteroplacental blood flow is reduced and this affects placental oxygen transfer to the fetus, causing a fall in fetal

  10. Obstetrical Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures of ... What are the limitations of Obstetrical Ultrasound Imaging? Obstetric ultrasound cannot identify all fetal abnormalities. Consequently, when ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  13. 4D and Doppler sonography in the diagnosis and surveillance of a true cord knot

    OpenAIRE

    Scioscia, Marco; Fornalè, Mariangela; Bruni, Francesco; Peretti, Daniela; Trivella, Giamberto

    2010-01-01

    Abstract Prenatal diagnosis of a true knot of the umbilical cord is very often an incidental observation at ultrasound with a difficult differential diagnosis between true and false knots. Furthermore, very little is known about the optimal management of these cases. We report the importance of color Doppler and four-dimensional ultrasound for the differential diagnosis in case of suspect of cord knot and the impact of Doppler flow velocimetry in the longitudinal management of such...

  14. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  15. Advances in Doppler OCT

    Science.gov (United States)

    Liu, Gangjun; Chen, Zhongping

    2014-01-01

    We review the principle and some recent applications of Doppler optical coherence tomography (OCT). The advances of the phase-resolved Doppler OCT method are described. Functional OCT algorithms which are based on an extension of the phase-resolved scheme are also introduced. Recent applications of Doppler OCT for quantification of flow, imaging of microvasculature and vocal fold vibration, and optical coherence elastography are briefly discussed. PMID:24443649

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... and helps assure safe and accurate placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as clots) narrowing of vessels tumors and ...

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... an area of tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study is performed, your child may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Once the imaging ...

  18. Frequency Diversity Technique for Space-borne Radar Doppler Measurements

    Data.gov (United States)

    National Aeronautics and Space Administration — Doppler velocity measurement has been challenging for radars onboard fast moving platforms (such as spacecrafts) or radars with rapid scanning antennas due to the...

  19. Role of Doppler US and MRI in diagnosis of placenta accreta ...

    African Journals Online (AJOL)

    The aim of this work is to evaluate the role of Doppler US and MRI in the diagnosis of placenta accreta. Patients and methods: During period between 2012 to 2013, 120 pregnant patients with previous cesarean section were investigated by ultrasound and Doppler and then in suspected cases MRI was obtained (10 cases).

  20. Added value of cerebro-placental ratio and uterine artery Doppler at routine third trimester screening as a predictor of SGA and FGR in non-selected pregnancies.

    Science.gov (United States)

    Rial-Crestelo, M; Martinez-Portilla, R J; Cancemi, A; Caradeux, J; Fernandez, L; Peguero, A; Gratacos, E; Figueras, Francesc

    2018-03-04

    The objective of this study is to determine the added value of cerebroplacental ratio (CPR) and uterine Doppler velocimetry at third trimester scan in an unselected obstetric population to predict smallness and growth restriction. We constructed a prospective cohort study of women with singleton pregnancies attended for routine third trimester screening (32 +0 -34 +6 weeks). Fetal biometry and fetal-maternal Doppler ultrasound examinations were performed by certified sonographers. The CPR was calculated as a ratio of the middle cerebral artery to the umbilical artery pulsatility indices. Both attending professionals and patients were blinded to the results, except in cases of estimated fetal weight < p10. The association between third trimester Doppler parameters and small for gestational age (SGA) (birth weight <10th centile) and fetal growth restriction (FGR) (birth weight below the third centile) was assessed by logistic regression, where the basal comparison was a model comprising maternal characteristics and estimated fetal weight (EFW). A total of 1030 pregnancies were included. The mean gestational age at scan was 33 weeks (SD 0.6). The addition of CPR and uterine Doppler to maternal characteristics plus EFW improved the explained uncertainty of the predicting models for SGA (15 versus 10%, p < .001) and FGR (12 versus 8%, p = .03). However, the addition of CPR and uterine Doppler to maternal characteristics plus EFW only marginally improved the detection rates for SGA (38 versus 34% for a 10% of false positives) and did not change the predictive performance for FGR. The added value of CPR and uterine Doppler at 33 weeks of gestation for detecting defective growth is poor.

  1. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  2. Ultrasound surveillance of endovascular aneurysm repair: a safe modality versus computed tomography.

    Science.gov (United States)

    Collins, John T; Boros, Michael J; Combs, Kristin

    2007-11-01

    Routine ultrasound surveillance is adequate and safe for monitoring endovascular aneurysm repairs (EVARs). A retrospective chart review including 160 endograft patients was performed from August 2000 to September 2005. All ultrasound examinations (n = 359) were performed by a board-certified vascular surgery group's accredited laboratory. Registered vascular technologists utilized the same equipment consisting of Siemens Antares high-definition ultrasonography with tissue harmonics and color flow Doppler. An identical protocol was followed by each technologist: scan body and both limbs of the endograft and distal iliac vessels, measure anterior-posterior aneurysm sac size, and detect intrasac pulsatility and color flow. Statistical analysis utilized Pearson's correlation coefficient and the paired t-test. Forty-one endoleaks were discovered out of the 359 exams (11.4%). There were type I (7, 17%), type II (26, 63%), and combined type I with type II (8, 20%) endoleaks. Correlation with computed tomography (CT) was obtained in 35 of these cases. CT discovered three endoleaks that were not seen with ultrasound. However, these particular ultrasound exams were inadequate due to additional factors (bowel gas, body habitus, hernia), which prompted CT investigation and, hence, endoleak discovery. Of the 41 endoleaks found on ultrasound, only 14 were seen on CT. Specifically, 26 type II endoleaks were seen with ultrasound versus only nine during CT. Additional factors addressed included comparison between ultrasound and CT of residual aneurysm sac measurements and conditions limiting ultrasound examination. Although criticized in the past, color flow ultrasonography is a safe and effective modality for surveillance of aortic endografts. Utilizing ultrasound to analyze abdominal aortic aneurysm (AAA) sac dimensions and endoleak detection is statistically sound for screening AAA status post-EVAR.

  3. Does Dopplersignal enhancement with Levovist improve the diagnostic confidence of duplex scanning of the iliac arteries?--(A pilot study with correlation to intravascular ultrasound)

    DEFF Research Database (Denmark)

    Vogt, K C; Jensen, F; Schroeder, T V

    1998-01-01

    To evaluate whether echo-enhancement with Levovist improves the diagnostic confidence of duplex scanning of the iliac arteries.......To evaluate whether echo-enhancement with Levovist improves the diagnostic confidence of duplex scanning of the iliac arteries....

  4. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  5. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  6. Valuation analysis of renal Doppler ultrasound in pediatric patients at the Hospital Nacional de Ninos: resistance indices obtained in obstructive uropathy in children of 0 to 12 years from November to July, 2011

    International Nuclear Information System (INIS)

    Quijano Solis, Rocio

    2011-01-01

    The renal resistance index found in the pediatric population of 0 to 12 years with obstructive uropathy at the Hospital Nacional de Ninos has become known by analyzing resistance indices obtained through Doppler evaluation during the period November 2010 to July 2011. A relationship is established with the degree of dilatation of the collecting system. The renal resistance index determined by interrogation Doppler of intrarenal renal arteries. A comparison is performed by sex and age with severity of obstructive uropathy and respective resistance index, normal values of resistance index in renal and intrarenal arteries were obtained, in addition, a correlation was performed between the degree of severity of dilatation of the collecting system and resistance index in pediatric patients with obstructive uropathy [es

  7. Evaluation of a point-of-care ultrasound scan list in a resource-limited emergency centre in Addis Ababa Ethiopia

    Directory of Open Access Journals (Sweden)

    Maja Stachura

    2017-09-01

    Discussion: In this urban, low-resource, academic EC in Ethiopia, POCUS provided clinically relevant information for patient management, particularly for polytrauma, undifferentiated shock and undifferentiated dyspnea. Results have subsequently been used to develop a locally relevant emergency department ultrasound curriculum for Ethiopia’s first emergency medicine residency program.

  8. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  9. Differentiation of midbrain cystic lesions by duplex Doppler US

    International Nuclear Information System (INIS)

    Horgan, J.G.; Taylor, K.J.W.; Sarwar, M.; Weltin, G.; Klier, L.

    1986-01-01

    The addition of Doppler technology to an ultrasound imaging system allows easy differentiation of vascular from nonvascular masses. In addition, the characteristic flow in different arteries, veins, and arteriovenous communications allows accurate diagnosis of vascular structures. Cystic lesions in the region of the midbrain are uncommon but not rare in neonates, and it is important to differentiate between quadrigeminal plate cysts and vein of Galen aneurysms. Six neonates with cystic midbrain structures lying above the tectum were studied over a 2-year period. All were examined with duplex Doppler imaging and followed up by CT and angiography, when indicated. In two of the six infants a highly vascular signal was demonstrated with high flow rates and low impedance. Subsequent CT and angiography revealed typical vein of Galen aneurysms. The remaining four infants had cystic lesions that were avascular on Doppler imaging and demonstrated no enhancement on CT. Duplex Doppler imaging is helpful in the initial investigation of patients with midbrain cystic lesions

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound is most often performed to evaluate the: uterus cervix ovaries fallopian tubes bladder Pelvic ultrasound exams ... to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... special ultrasound technique that allows the physician to see and evaluate blood flow through arteries and veins ... development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . Ultrasound ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... What are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and ... as the liver or kidneys. top of page What are some common uses of the procedure? In ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... What are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is ... in front of the rectum. top of page What are some common uses of the procedure? A ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  17. Proposal for standardised ultrasound descriptors of abnormally invasive placenta (AIP)

    DEFF Research Database (Denmark)

    Collins, Sally L; Ashcroft, Anna; Braun, Thorsten

    2016-01-01

    were examined for wording used to describe AIP signs. These were extracted and grouped by ultrasound modality, and synonymous or identical terms identified. The group agreed on six unified descriptors for 2D greyscale signs, four for 2D colour Doppler and one for 3D power Doppler. Four papers included...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... fitting clothing for an ultrasound exam. Other preparation depends on the type of examination. For some scans, your doctor may ask you to withhold food and drink for several hours before your child's ...

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  1. Medical Imaging with Ultrasound: Some Basic Physics.

    Science.gov (United States)

    Gosling, R.

    1989-01-01

    Discussed are medical applications of ultrasound. The physics of the wave nature of ultrasound including its propagation and production, return by the body, spatial and contrast resolution, attenuation, image formation using pulsed echo ultrasound techniques, measurement of velocity and duplex scanning are described. (YP)

  2. Wrist ultrasound analysis of patients with early rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    J.A. Mendonça

    2011-01-01

    Full Text Available In the present study, we evaluated 42 wrists using the semi-quantitative scales power Doppler ultrasound (PDUS and gray scale ultrasound (GSUS with scores ranging from 0 to 3 and correlated the results with clinical, laboratory and radiographic data. Twenty-one patients (17 women and 4 men with rheumatoid arthritis according to criteria of the American College of Rheumatology were enrolled in the study from September 2008 to July 2009 at Universidade Estadual de Campinas (UNICAMP. The average disease duration was 14 months. The patients were 66.6% Caucasians and 33.3% non-Caucasians, with a mean age of 42 and 41 years, respectively. A dorsal longitudinal scan was performed by ultrasound on the radiocarpal and midcarpal joints using GE LOGIQ XP-linear ultrasound and a high frequency (8-10 MHz transducer. All patients were X-rayed, and the Larsen score was determined for the joints, with grades ranging from 0 to V. This study showed significant correlations between clinical, sonographic and laboratory data: GSUS and swollen right wrist (r = 0.546, GSUS of right wrist and swelling of left wrist (r = 0.511, PDUS of right wrist and pain in left wrist (r = 0.436, PDUS of right wrist and C-reactive protein (r = 0.466. Ultrasound can be considered a useful tool in the diagnosis of synovitis in early rheumatoid arthritis mainly when the anti-cyclic citrullinated peptide and rheumatoid factor are negative, and can lead to an early change in the therapeutic decision.

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary bladder ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  6. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  7. [Carotid artery injury: value of Doppler screening in head injured patients].

    Science.gov (United States)

    Terminassian, A; Bonnet, F; Guerrini, P; Ricolfi, F; Delaunay, F; Beydon, L; Catoire, P

    1992-01-01

    A case is reported of a patient with a traumatic aneurysm of the intracranial part of the carotid artery occurring after a traffic accident. The patient was admitted in coma (Glasgow score 5), and presented with a depressed fracture of the frontal and parietal bones, a fracture of the left petrous pyramid and of the left anterior clinoid process, as well as of the right tympanic bone and temporomandibular joint. The borders of the left carotid canal seemed unaltered. Despite the lack of localised neurological signs, cervical and transcranial Doppler ultrasonography was carried out. Intracranial carotid blood flow was found to be altered on both sides. Angiography showed a false carotid aneurysm on the left side (carotid siphon portion C3), and a moderate irregular stenosis of the C2 part on the right. There were no brain lesions on the CT scan. Prophylactic treatment with heparin was started. The patient recovered normal consciousness within a fortnight. The false aneurysm increased in volume and was treated by embolisation. Flow speeds in the carotid siphons also returned to normal. The usefulness of routine screening of patients with petrous bone fractures with Doppler ultrasound is discussed.

  8. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    Science.gov (United States)

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (ptime of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  10. Clinical Brain Death with False Positive Radionuclide Cerebral Perfusion Scans

    Directory of Open Access Journals (Sweden)

    Sindhaghatta Venkatram

    2015-01-01

    Full Text Available Practice guidelines from the American Academy of Neurology for the determination of brain death in adults define brain death as “the irreversible loss of function of the brain, including the brainstem.” Neurological determination of brain death is primarily based on clinical examination; if clinical criteria are met, a definitive confirmatory test is indicated. The apnea test remains the gold standard for confirmation. In patients with factors that confound the clinical determination or when apnea tests cannot safely be performed, an ancillary test is required to confirm brain death. Confirmatory ancillary tests for brain death include (a tests of electrical activity (electroencephalography (EEG and somatosensory evoked potentials and (b radiologic examinations of blood flow (contrast angiography, transcranial Doppler ultrasound (TCD, and radionuclide methods. Of these, however, radionuclide studies are used most commonly. Here we present data from two patients with a false positive Radionuclide Cerebral Perfusion Scan (RCPS.

  11. [Color Doppler sonography of focal abdominal lesions].

    Science.gov (United States)

    Licanin, Zoran; Lincender, Lidija; Djurović, V; Salihefendić, Nizama; Smajlović, Fahrudin

    2004-01-01

    Color Doppler sonography (CDS--spectral, color and power), harmonic imaging techniques (THI, PHI), possibility of 3D analysis of picture, usage of contrast agents, have raised the values of ultrasound as a diagnostic method to a very high level. THI--non-linear gray scale modality, is based on the processing of higher reflected frequencies, that has improved a picture resolution, which is presented with less artifacts and limiting effects of obesity and gases. Ultrasound contrast agents improve analysis of micro and macro circulation of the examined area, and with the assessment of velocity of supply in ROI (wash in), distribution and time of signal weakening (wash out), are significantly increasing diagnostic value of ultrasound. Besides the anatomical and topographic presentation of examined region (color, power), Color Doppler sonography gives us haemodynamic-functional information on vascularisation of that region, as well as on pathologic vascularisation if present. Avascular aspect of a focal pathologic lesion corresponds to a cyst or haematoma, while coloration and positive spectral curve discover that anechogenic lesions actually represents aneurysms, pseudoaneurysms or AVF. In local inflammatory lesion, abscess in an acute phase, CDS shows first increased, and then decreased central perfusion, while in a chronic phase, a pericapsular vascularisation is present. Contribution of CDS in differentiation of hepatic tumors (hemangioma, HCC and metastasis) is very significant. Central color dots along the peripheral blood vessels and the blush phenomenon are characteristics of capillary hemangioma, peritumoral vascular ring "basket" of HCC, and "detour" sign of metastasis. The central artery, RI from 0.45 to 0.60 and radial spreading characterize FNH. Hepatic adenoma is characterized by an intratumoral vein, and rarely by a vascular hallo. Further on, blood velocity in tumor defined by Color Doppler, distinguishes malignant from benign lesion, where 40 cm/s is a

  12. [Ultrasound scanning of the distraction regenerate in case of multilocus elongation of the fragments in patients with defects of long bones].

    Science.gov (United States)

    Menshikova, T I; Borzunov, D Iu; Dolganova, T I

    2014-01-01

    It was done ultrasound examination of distraction regenerates in patients with defect of bone tissue. The first group included 4 patients who had the size of congenital bone tissue defect 15.8±8.1 cm; the second group (3 patients) included posttraumatic defects with defect size 11.75±3.6 cm; the third group (4 patients) included posttraumatic defects with defect size 11±5.3 cm. It was discovered the particularities of distraction regenerate structural condition in case of low level of reparative osteogenesis. In the first group "ischemic" regenerate was characterized by slow formation of bone trabecules. In the second group "ischemic" regenerate had one or two hypo-echogenic cystic-like formations in the intermediate regenerate area. All patients of the third group had organotypic remodeling of the regenerate according to terms of distraction and fixation.

  13. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  14. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  15. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  16. Gold nanorods as a contrast agent for Doppler optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Bo Wang

    Full Text Available To investigate gold nanorods (GNRs as a contrast agent to enhance Doppler optical coherence tomography (OCT imaging of the intrascleral aqueous humor outflow.A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×10(12 GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus.At the GNR concentration of 0.7×10(12 GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of -0.025 to 0.037 mm/s (p = 0.6435. Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system.GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes.

  17. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  18. Abscess scan - radioactive

    Science.gov (United States)

    ... blood cells are tagged with a radioactive substance ( radioisotope ) called indium. The cells are then injected back ... you have or had any of the following medical conditions, procedures, or treatments, as they can interfere with ... Often, other imaging tests such as an ultrasound or CT scan ...

  19. Cerebrovascular reactivity in migraineurs as measured by transcranial Doppler

    International Nuclear Information System (INIS)

    Thomas, T.D.; Harpold, G.J.

    1990-01-01

    Transcranial Doppler ultrasound is a relatively new diagnostic modality which allows the non-invasive assessment of intracranial circulation. A total of 10 migraine patients were studied and compared to healthy controls without headaches. Migraineurs during the headache-free interval demonstrated excessive cerebrovascular reactivity to CO 2 , evidenced by an increase in middle cerebral artery blood flow velocity of 47% ± 15% compared to 28% ± 14% in controls. Differences between the two study groups revealed no significant decrease in middle cerebral artery blood flow velocity with hypocapnia. However, the differences between middle cerebral artery blood flow velocity during hyperventilation and CO 2 inhalation were significantly different comparing migraineurs and controls. Instability of the baseline blood flow velocities was also noted in migraineurs during the interictal period. Characteristics which may allow differentiation of migraineurs from other headache populations could possibly be obtained from transcranial Doppler ultrasound flow studies. 24 refs., 2 tabs

  20. The impacts of piezoelectric element's defects on color and power doppler images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Sung [Dept. of Radiotechnology, Cheju Halla University, Cheju (Korea, Republic of)

    2015-12-15

    An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe’s defected elements on power and color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements’ defects increase in color and power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.