WorldWideScience

Sample records for distribution system connected

  1. The Newcastle connection: A software subsystem for constructing distributed UNIX systems

    International Nuclear Information System (INIS)

    Randell, B.

    1985-01-01

    The Newcastle connection is a software subsystem that can be added to each of a set of physically interconnected UNIX or UNIX look-alike systems, so as to construct a distributed system which is functionally indistinguishable at both the user and the program level from a conventional single-processor UNIX system. The techniques used are applicable to a variety and multiplicity of both local and wide area networks, and enable all issues of inter-processor communication, network protocols, etc., to be hidden. A brief account is given of experience with such distributed systems, the first of which was constructed in 1982 using a set of PDP11s running UNIX Version 7, and connected by a Cambridge Ring - since this date the Connection has been used to construct distributed systems based on various other computers and versions of UNIX, both at Newcastle and elsewhere. The final sections compare our scheme to various precursor schemes and discuss its potential relevance to other operating systems. (orig.)

  2. Impact of SONET digital cross-connect system architecture on distributed restoration

    International Nuclear Information System (INIS)

    Wu, Tsong-ho; Kobrinski, H.; Lakshman, T.V.

    1994-01-01

    The viability of distributed control restoration using Digital Cross-Connect Systems (DC's) depends on its capability for restoring services within specified time requirements, and its economics for providing restoration compared to other alternatives. In this paper, we report a Bellcore study for the impact of the DCS architecture on distributed restoration. This study concludes that currently proposed distributed control DCS self-healing schemes may not meet the 2-s restoration objective for large metropolitan Local Exchange Carrier's networks, regardless of the distributed algorithm used, if the present DCS system architecture which uses serial message processing and serial path cross-connection remains unchanged. This paper also discusses several DCS architecture enhancement options, including a parallel processing/cross-connect DCS architecture, which may improve the service restoration time. 20 refs

  3. Fuzzy comprehensive evaluation for grid-connected performance of integrated distributed PV-ES systems

    Science.gov (United States)

    Lv, Z. H.; Li, Q.; Huang, R. W.; Liu, H. M.; Liu, D.

    2016-08-01

    Based on the discussion about topology structure of integrated distributed photovoltaic (PV) power generation system and energy storage (ES) in single or mixed type, this paper focuses on analyzing grid-connected performance of integrated distributed photovoltaic and energy storage (PV-ES) systems, and proposes a comprehensive evaluation index system. Then a multi-level fuzzy comprehensive evaluation method based on grey correlation degree is proposed, and the calculations for weight matrix and fuzzy matrix are presented step by step. Finally, a distributed integrated PV-ES power generation system connected to a 380 V low voltage distribution network is taken as the example, and some suggestions are made based on the evaluation results.

  4. Global distribution of grid connected electrical energy storage systems

    Directory of Open Access Journals (Sweden)

    Katja Buss

    2016-06-01

    Full Text Available This article gives an overview of grid connected electrical energy storage systems worldwide, based on public available data. Technologies considered in this study are pumped hydroelectric energy storage (PHES, compressed air energy storage (CAES, sodium-sulfur batteries (NaS, lead-acid batteries, redox-flow batteries, nickel-cadmium batteries (NiCd and lithium-ion batteries. As the research indicates, the worldwide installed capacity of grid connected electrical energy storage systems is approximately 154 GW. This corresponds to a share of 5.5 % of the worldwide installed generation capacity. Furthermore, the article gives an overview of the historical development of installed and used storage systems worldwide. Subsequently, the focus is on each considered technology concerning the current storage size, number of plants and location. In summary it can be stated, PHES is the most commonly used technology worldwide, whereas electrochemical technologies are increasingly gaining in importance. Regarding the distribution of grid connected storage systems reveals the share of installed storage capacity is in Europe and Eastern Asia twice as high as in North America.

  5. Determining on-fault magnitude distributions for a connected, multi-fault system

    Science.gov (United States)

    Geist, E. L.; Parsons, T.

    2017-12-01

    A new method is developed to determine on-fault magnitude distributions within a complex and connected multi-fault system. A binary integer programming (BIP) method is used to distribute earthquakes from a 10 kyr synthetic regional catalog, with a minimum magnitude threshold of 6.0 and Gutenberg-Richter (G-R) parameters (a- and b-values) estimated from historical data. Each earthquake in the synthetic catalog can occur on any fault and at any location. In the multi-fault system, earthquake ruptures are allowed to branch or jump from one fault to another. The objective is to minimize the slip-rate misfit relative to target slip rates for each of the faults in the system. Maximum and minimum slip-rate estimates around the target slip rate are used as explicit constraints. An implicit constraint is that an earthquake can only be located on a fault (or series of connected faults) if it is long enough to contain that earthquake. The method is demonstrated in the San Francisco Bay area, using UCERF3 faults and slip-rates. We also invoke the same assumptions regarding background seismicity, coupling, and fault connectivity as in UCERF3. Using the preferred regional G-R a-value, which may be suppressed by the 1906 earthquake, the BIP problem is deemed infeasible when faults are not connected. Using connected faults, however, a solution is found in which there is a surprising diversity of magnitude distributions among faults. In particular, the optimal magnitude distribution for earthquakes that participate along the Peninsula section of the San Andreas fault indicates a deficit of magnitudes in the M6.0- 7.0 range. For the Rodgers Creek-Hayward fault combination, there is a deficit in the M6.0- 6.6 range. Rather than solving this as an optimization problem, we can set the objective function to zero and solve this as a constraint problem. Among the solutions to the constraint problem is one that admits many more earthquakes in the deficit magnitude ranges for both faults

  6. Analysis of the influences of grid-connected PV power system on distribution grids

    Directory of Open Access Journals (Sweden)

    Dumitru Popandron

    2013-12-01

    Full Text Available This paper presents the analysis of producing an electric power of 2.8 MW using a solar photovoltaic plant. The PV will be grid connected to the distribution network. The study is focused on the influences of connecting to the grid of a photovoltaic system, using modern software for analysis, modeling and simulation in power systems.

  7. Distributed control system for parallel-connected DC boost converters

    Science.gov (United States)

    Goldsmith, Steven

    2017-08-15

    The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

  8. Distributed Power System Virtual Inertia Implemented by Grid-Connected Power Converters

    DEFF Research Database (Denmark)

    Fang, Jingyang; Li, Hongchang; Tang, Yi

    2018-01-01

    Renewable energy sources (RESs), e.g. wind and solar photovoltaics, have been increasingly used to meet worldwide growing energy demands and reduce greenhouse gas emissions. However, RESs are normally coupled to the power grid through fast-response power converters without any inertia, leading...... to decreased power system inertia. As a result, the grid frequency may easily go beyond the acceptable range under severe frequency events, resulting in undesirable load-shedding, cascading failures, or even large-scale blackouts. To address the ever-decreasing inertia issue, this paper proposes the concept...... of distributed power system virtual inertia, which can be implemented by grid-connected power converters. Without modifications of system hardware, power system inertia can be emulated by the energy stored in the dc-link capacitors of grid-connected power converters. By regulating the dc-link voltages...

  9. The challenges of connecting generation to distribution systems: a utility perspective

    International Nuclear Information System (INIS)

    Kropp, F.

    2004-01-01

    'Full text:' This presentation discusses the technical, financial and regulatory barriers to connecting generation to Distribution Systems in Ontario. Case studies will be used to provide examples of the operational and technical challenges that impact the utility as well as a discussion on the site-specific advantages and disadvantages (to the utility) of the generation connections. These studies will include discussions on the problems and lessons learned with respect to the overall project implementation and the contractual agreements. The case studies will be complemented by an explanation of the financial constraints (both short term and long term) associated with the connections, and the regulatory issues that impact the financial recovery models including net and gross load billing. (author)

  10. Grid-connected distributed solar power systems

    Science.gov (United States)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  11. Banding of connection standards for distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-04

    This report presents the views of distributed network operators (DNOs), developers, equipment manufacturers and consultants on the current banding of distributed generation in terms of connection standards and recommendations. The Documents ER G59/1, ER G75/1, ER G83/1 and ETR 113/1 covering recommendations for the connection of embedded generating plant to distribution systems and guidance notes for the protection of embedded generating plant are examined. The way in which the recommendations are applied in practice is investigated. Multiple distribution generator installations, fault ride through, and banding are considered as well as both protection required and maximum generator sizes at respective voltage levels.

  12. DISTRIBUTED GRID-CONNECTED PHOTOVOLTAIC POWER SYSTEM EMISSION OFFSET ASSESSMENT: STATISTICAL TEST OF SIMULATED- AND MEASURED-BASED DATA

    Science.gov (United States)

    This study assessed the pollutant emission offset potential of distributed grid-connected photovoltaic (PV) power systems. Computer-simulated performance results were utilized for 211 PV systems located across the U.S. The PV systems' monthly electrical energy outputs were based ...

  13. The Impact of Connecting Distributed Generation to the Distribution System

    Directory of Open Access Journals (Sweden)

    E. V. Mgaya

    2007-01-01

    Full Text Available This paper deals with the general problem of utilizing of renewable energy sources to generate electric energy. Recent advances in renewable energy power generation technologies, e.g., wind and photovoltaic (PV technologies, have led to increased interest in the application of these generation devices as distributed generation (DG units. This paper presents the results of an investigation into possible improvements in the system voltage profile and reduction of system losses when adding wind power DG (wind-DG to a distribution system. Simulation results are given for a case study, and these show that properly sized wind DGs, placed at carefully selected sites near key distribution substations, could be very effective in improving the distribution system voltage profile and reducing power losses, and hence could  improve the effective capacity of the system

  14. Power system services provided by inverter connected distributed energy resources

    DEFF Research Database (Denmark)

    For the last few years there has been a significant increase of DER units in Denmark, of those units more and more are connected to the power system using inverters. These inverter connected units have the potential to support the electrical power system with various power system services. One...

  15. A guide to distribution network operator connection and use of system methodologies and charging

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-04

    This report aims to help those developing or planning to develop power generation schemes connected to local electricity distribution systems (distributed generation) to understand the various regional network charging schemes in the UK. It is also intended to act as a route map to understand distribution charges as they are currently applied; further changes in charging arrangements between 2005 and 2010 are indicated and signposts to sources of further information are provided. The report explains the structure of distribution networks, the outcome of the regulatory review of distribution pricing undertaken by the Office of Gas and Electricity Markets (Ofgem) applicable from 1 April 2005 and how this affects distribution network operators (DNOs) and their distribution charges. The report considers: the energy policy framework in the UK; the commercial and regulatory framework that applies to distributed generators; DNOs and their regulatory framework; network charging methodologies and principles; charging statements; and areas of likely future changes. Individual schedules and contact details are given in an appendix for each DNO.

  16. Technical guide to the connection of generation to the distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Jarrett, K.; Hedgecock, J.; Gregory, R.; Warham, T.

    2003-07-01

    This guide provides a 'route map' of the processes of getting a generation scheme connected to the network and is intended to help developers of any form of distributed generation connected to the UK's local electricity networks, eg: renewable energy schemes; waste-to-energy schemes; on-site generation and combined heat and power (CHP) schemes; and peak lopping schemes using back-up generators. Where necessary, the guide distinguishes between arrangements that apply in Scotland and those that apply in England and Wales. The guide aims to: provide background information about the electricity industry; highlight common technical issues that arise during connection negotiation and their implications for distribution network operators (DNOs) and developers; examine the main factors affecting connection costs and timescales for achieving connections; and identify the different types of contracts relating to connection. The report considers the connection process, the connection application process and timescales, costs and charges, competition in connection, the structure of the UK electricity industry, the statutory framework, the effects of distributed generation of the distribution system, earthing and protection design, safety issues and DNO network information. It includes a glossary, checklists, useful contact details and information about standards and other useful documents.

  17. Establishment of key grid-connected performance index system for integrated PV-ES system

    Science.gov (United States)

    Li, Q.; Yuan, X. D.; Qi, Q.; Liu, H. M.

    2016-08-01

    In order to further promote integrated optimization operation of distributed new energy/ energy storage/ active load, this paper studies the integrated photovoltaic-energy storage (PV-ES) system which is connected with the distribution network, and analyzes typical structure and configuration selection for integrated PV-ES generation system. By combining practical grid- connected characteristics requirements and technology standard specification of photovoltaic generation system, this paper takes full account of energy storage system, and then proposes several new grid-connected performance indexes such as paralleled current sharing characteristic, parallel response consistency, adjusting characteristic, virtual moment of inertia characteristic, on- grid/off-grid switch characteristic, and so on. A comprehensive and feasible grid-connected performance index system is then established to support grid-connected performance testing on integrated PV-ES system.

  18. CODAC systems arrangement and connectivity

    Energy Technology Data Exchange (ETDEWEB)

    Gulati, Hitesh Kumar, E-mail: hkgulati@gmail.com; Beltran, David; Kuehn, Ingo; Kotamaki, Miikka; Makijarvi, Petri; Wallander, Anders

    2013-10-15

    Highlights: •The CODAC system is a distributed system and scattered in many buildings connected with cables. Building construction for ITER project is just started so volume reservation for different CODAC component is done based on the content of this paper. •The 2-D and 3-D diagrams have been prepared which are showing the location of different CODAC equipment and their connectivity. •The different requirements regarding raised access (false) floor, power requirements, heat load, installation, maintenance, redundancy, and segregation etc. have been considered. -- Abstract: The CODAC system is responsible for integrating all ITER plant system Instrumentation and Control systems and enabling operation of ITER machine as a single integrated facility. The different ITER plant systems and their Instrumentation and Control systems are distributed in several ITER buildings on the ITER platform. The CODAC systems have to interface with all these distributed plant system I and C systems. CODAC systems will be composed of several physical systems or components like networks, servers, workstations (terminals), large displays, PSH, storage systems etc. Several rooms in different buildings have been defined to house all above equipment. The site-wide CODAC network infrastructure will be based on a dual (redundant) star topology. The two redundant star points will house the core networking switches. These redundant core switches will be installed in different buildings. Cubicles used for network infrastructure are distributed among “hutches,” where a CODAC hutch is a room or area equipped with appropriate heating, ventilation, air conditioning and uninterruptible power which will be directly connected through two star points. The responsibility of CODAC infrastructure ends up to the plant system I and C cubicles so several passive CODAC network panels have identified in all I and C rooms of different plant buildings. This CODAC Network Panel will be the physical

  19. Drinking Water Distribution Systems

    Science.gov (United States)

    Learn about an overview of drinking water distribution systems, the factors that degrade water quality in the distribution system, assessments of risk, future research about these risks, and how to reduce cross-connection control risk.

  20. Enhanced distributed energy resource system

    Science.gov (United States)

    Atcitty, Stanley [Albuquerque, NM; Clark, Nancy H [Corrales, NM; Boyes, John D [Albuquerque, NM; Ranade, Satishkumar J [Las Cruces, NM

    2007-07-03

    A power transmission system including a direct current power source electrically connected to a conversion device for converting direct current into alternating current, a conversion device connected to a power distribution system through a junction, an energy storage device capable of producing direct current connected to a converter, where the converter, such as an insulated gate bipolar transistor, converts direct current from an energy storage device into alternating current and supplies the current to the junction and subsequently to the power distribution system. A microprocessor controller, connected to a sampling and feedback module and the converter, determines when the current load is higher than a set threshold value, requiring triggering of the converter to supply supplemental current to the power transmission system.

  1. Internet services for planning distributed generation connections

    Energy Technology Data Exchange (ETDEWEB)

    Curry, D.; Morgan, A.; Barbier, C.; Reay, P.

    2005-07-01

    The required publication by distributed network operators (DNOs) of details of the current state of their network systems and future planned developments in the form of Long Term Development Statements (LTDS) are discussed. This project aims to increase the usefulness of the information in the LTDS by making it available on the internet and by providing an initial assessment of connection opportunities and the possibility of viewing existing renewable generation projects. The services developed covered data loading, data visualisation, security, connection assessment, reporting, and generation site registration. The benefits of an electronic version of the LTDS are highlighted.

  2. Adaptive Protection Scheme for a Distribution System Considering Grid-Connected and Islanded Modes of Operation

    Directory of Open Access Journals (Sweden)

    Yavuz Ates

    2016-05-01

    Full Text Available The renewable energy-based distributed generation (DG implementation in power systems has been an active research area during the last few decades due to several environmental, economic and political factors. Although the integration of DG offers many advantages, several concerns, including protection schemes in systems with the possibility of bi-directional power flow, are raised. Thus, new protection schemes are strongly required in power systems with a significant presence of DG. In this study, an adaptive protection strategy for a distribution system with DG integration is proposed. The proposed strategy considers both grid-connected and islanded operating modes, while the adaptive operation of the protection is dynamically realized considering the availability of DG power production (related to faults or meteorological conditions in each time step. Besides, the modular structure and fast response of the proposed strategy is validated via simulations conducted on the IEEE 13-node test system.

  3. Detection of contamination of municipal water distribution systems

    Science.gov (United States)

    Cooper, John F [Oakland, CA

    2012-01-17

    A system for the detection of contaminates of a fluid in a conduit. The conduit is part of a fluid distribution system. A chemical or biological sensor array is connected to the conduit. The sensor array produces an acoustic signal burst in the fluid upon detection of contaminates in the fluid. A supervisory control system connected to the fluid and operatively connected to the fluid distribution system signals the fluid distribution system upon detection of contaminates in the fluid.

  4. Going smarter in the connection of distributed generation

    International Nuclear Information System (INIS)

    Anaya, Karim L.; Pollitt, Michael G.

    2017-01-01

    This study explores and quantifies the benefits of connecting more distributed generation (DG) with and without the use of smart connections in Great Britain. We examine the impacts on different parties (Distribution Network Operators, wider society and generators). As illustration we use a specific case study. Alternative connection scenarios are proposed (with partial and full interruptible capacity quota under a mix of generation with different technology-specific curtailment levels) for integrating DG units in a constrained area of the East of England covered by the Flexible Plug and Play project. The smart (interruptible) connection option is the preferred option across all the scenarios (higher NPV/MW). The analysis of the distribution of benefits between the different parties suggests that generators capture most of the benefits while DNOs and wider society capture much less benefit. A smart connection incentive, which recreates the benefits to DNOs from an earlier losses incentive, is proposed. By contrast with other societally desirable metrics which are usually incentivised or penalised, there is currently no direct connection between more DG MWs connected and DNO incentive payments. Our proposed smart connection incentive, by charging DG for smarter connection may help to distribute more efficiently the benefits for connecting more DG. - Highlights: • Three different dimensions of going smarter to connect DG are discussed. • Benefits for connecting DG in a constrained area (FPP project) are estimated. • Different DG connection scenarios are evaluated. • Generators benefit the most and wider society the least. • A smart connection incentive may help to reallocate the benefits of DG more efficiently.

  5. Distributed generation connected to the local network - a guide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This guide provides advice to the developers and operators of small distributed generation plant (including microgenerators) in the UK about the practical issues associated with connecting their plant and trading their output. Particular attention is given to sales revenues and how to access these revenue streams, including the mechanisms for purchasing Renewable Obligation Certificates (ROCs). The guide clarifies key terms, explains the wholesale trading system and provides an overview of sales opportunities (including ROCs and Levy Exemption Certificates (LECs)). Requirements on small distributed generation (including licensing, claiming class exemptions and metering) are described and the commercial aspects of connection (including the recent reduction in the barriers to connection) examined. Microgeneration (ie generators below 10 kW) issues are covered in their own chapter. The six appendices contain: background information about the industry; a list of purchasers of electricity from small distributed generators; descriptions of the generation, transmission and supply industries; information about industry standards and their governance; the role of government departments and institutions; and a glossary and other links.

  6. An improved algorithm for connectivity analysis of distribution networks

    International Nuclear Information System (INIS)

    Kansal, M.L.; Devi, Sunita

    2007-01-01

    In the present paper, an efficient algorithm for connectivity analysis of moderately sized distribution networks has been suggested. Algorithm is based on generation of all possible minimal system cutsets. The algorithm is efficient as it identifies only the necessary and sufficient conditions of system failure conditions in n-out-of-n type of distribution networks. The proposed algorithm is demonstrated with the help of saturated and unsaturated distribution networks. The computational efficiency of the algorithm is justified by comparing the computational efforts with the previously suggested appended spanning tree (AST) algorithm. The proposed technique has the added advantage as it can be utilized for generation of system inequalities which is useful in reliability estimation of capacitated networks

  7. A Simple Adaptive Overcurrent Protection of Distribution Systems With Distributed Generation

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2011-01-01

    current when the system is connected to the grid and when it is islanded. This paper proposes the use of adaptive protection, using local information, to overcome the challenges of the overcurrent protection in distribution systems with distributed generation. The trip characteristics of the relays...... are updated by detecting operating states (grid connected or island) and the faulted section. The paper also proposes faulted section detection using the time over-current characteristics of the protective relays. Simulation results show that the operating state and faulted section can be correctly identified......A significant increase in the penetration of distributed generation has resulted in a possibility of operating distribution systems with distributed generation in islanded mode. However, over-current protection of an islanded distribution system is still an issue due to the difference in fault...

  8. Grid-Connected Distributed Generation: Compensation Mechanism Basics

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, Alexandra Y [National Renewable Energy Laboratory (NREL), Golden, CO (United States); ; ; ; Zinaman, Owen R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-02

    This short report defines compensation mechanisms for grid-connected, behind-the-meter distributed generation (DG) systems as instruments that comprise three core elements: (1) metering and billing arrangements, (2) sell rate design, and (3) retail rate design. This report describes metering and billing arrangements, with some limited discussion of sell rate design. We detail the three possible arrangements for metering and billing of DG: net energy metering (NEM); buy all, sell all; and net billing.

  9. Evaluation of a Distributed Photovoltaic System in Grid-Connected and Standalone Applications by Different MPPT Algorithms

    Directory of Open Access Journals (Sweden)

    Ru-Min Chao

    2018-06-01

    Full Text Available Due to the shortage of fossil fuel and the environmental pollution problem, solar energy applications have drawn a lot of attention worldwide. This paper reports the use of the latest patented distributed photovoltaic (PV power system design, including the two possible maximum power point tracking (MPPT algorithms, a power optimizer, and a PV power controller, in grid-connected and standalone applications. A distributed PV system with four amorphous silicon thin-film solar panels is used to evaluate both the quadratic maximization (QM and the Steepest descent (SD MPPT algorithms. The system’s design is different for the QM or the SD MPPT algorithm being used. The test result for the grid-connected silicon-based PV panels will also be reported. Considering the settling time for the power optimizer to be 20 ms, the test result shows that the tracking time for the QM method is close to 200 ms, which is faster when compared with the SD method whose tracking time is 500 ms. Besides this, the use of the QM method provides a more stable power output since the tracking is restricted by a local power optimizer rather than the global tracking the SD method uses. For a standalone PV application, a solar-powered boat design with 18 PV panels using a cascaded MPPT controller is introduced, and it provides flexibility in system design and the effective use of photovoltaic energy.

  10. Dynamic voltage stability of a distribution system with high penetration of grid-connected photovoltaic type solar generators

    Directory of Open Access Journals (Sweden)

    Zetty Adibah Kamaruzzaman

    2016-06-01

    Full Text Available This paper presents the impact of grid-connected photovoltaic (PV generator on dynamic voltage stability of a power distribution system by considering solar intermittency, PV penetration level, and contingencies such as line outage and load increase. The IEEE 13 node test feeder is used as a test system, and a solar PV of 0.48 kV/0.5 MVA is integrated into the test system. Test results show that system voltage is stable at high PV penetration levels. Increase in load causes voltage instability, in which voltage drops below its allowable operating limit. Thus, increase in PV penetration level does not improve system voltage stability because the system experiences voltage collapse during line outage.

  11. Dynamic models for transient stability analysis of transmission and distribution systems with distributed generation : an overview

    NARCIS (Netherlands)

    Boemer, J.C.; Gibescu, M.; Kling, W.L.

    2009-01-01

    Distributed Generation is increasing in nowadays power systems. Small scale systems such as photovoltaic, biomass or small cogeneration plants are connected to the distribution level, while large wind farms will be connected to the transmission level. Both trends lead to a replacement of large

  12. Control and operation of distributed generation in distribution systems

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2011-01-01

    Many distribution systems nowadays have significant penetration of distributed generation (DG)and thus, islanding operation of these distribution systems is becoming a viable option for economical and technical reasons. The DG should operate optimally during both grid-connected and island...... algorithm, which uses average rate of change off requency (Af5) and real power shift RPS), in the islanded mode. RPS will increase or decrease the power set point of the generator with increasing or decreasing system frequency, respectively. Simulation results show that the proposed method can operate...

  13. Loss Allocation in a Distribution System with Distributed Generation Units

    DEFF Research Database (Denmark)

    Lund, Torsten; Nielsen, Arne Hejde; Sørensen, Poul Ejnar

    2007-01-01

    In Denmark, a large part of the electricity is produced by wind turbines and combined heat and power plants (CHPs). Most of them are connected to the network through distribution systems. This paper presents a new algorithm for allocation of the losses in a distribution system with distributed...... generation. The algorithm is based on a reduced impedance matrix of the network and current injections from loads and production units. With the algorithm, the effect of the covariance between production and consumption can be evaluated. To verify the theoretical results, a model of the distribution system...

  14. Artificial Bee Colony Algorithm for Transient Performance Augmentation of Grid Connected Distributed Generation

    Science.gov (United States)

    Chatterjee, A.; Ghoshal, S. P.; Mukherjee, V.

    In this paper, a conventional thermal power system equipped with automatic voltage regulator, IEEE type dual input power system stabilizer (PSS) PSS3B and integral controlled automatic generation control loop is considered. A distributed generation (DG) system consisting of aqua electrolyzer, photovoltaic cells, diesel engine generator, and some other energy storage devices like flywheel energy storage system and battery energy storage system is modeled. This hybrid distributed system is connected to the grid. While integrating this DG with the onventional thermal power system, improved transient performance is noticed. Further improvement in the transient performance of this grid connected DG is observed with the usage of superconducting magnetic energy storage device. The different tunable parameters of the proposed hybrid power system model are optimized by artificial bee colony (ABC) algorithm. The optimal solutions offered by the ABC algorithm are compared with those offered by genetic algorithm (GA). It is also revealed that the optimizing performance of the ABC is better than the GA for this specific application.

  15. Embedded generation connection incentives for distribution network operators

    Energy Technology Data Exchange (ETDEWEB)

    Williams, P.; Andrews, S.

    2002-07-01

    This is the final report with respect to work commissioned by the Department of Trade and Industry (DTI) as part of the New and Renewable Energy Programme into incentives for distribution network operators (DNOs) for the connection of embedded generation. This report, which incorporates the contents of the interim report submitted in February 2002, considers the implications of changes in the structure and regulation in the UK electricity industry on the successful technical and commercial integrated of embedded generation into distribution networks. The report examines: the obligations of public electricity suppliers (PESs); current DNO practices regarding the connection of embedded generation; the changes introduced by the Utilities Act 2000, including the impact of new obligations placed on DNOs on the connection of embedded generation and the requirements of the new Electricity Distribution Standard Licence conditions; and problems and prospects for DNO incentives.

  16. Reliability assessment of distribution power systems including distributed generations

    International Nuclear Information System (INIS)

    Megdiche, M.

    2004-12-01

    Nowadays, power systems have reached a good level of reliability. Nevertheless, considering the modifications induced by the connections of small independent producers to distribution networks, there's a need to assess the reliability of these new systems. Distribution networks present several functional characteristics, highlighted by the qualitative study of the failures, as dispersed loads at several places, variable topology and some electrotechnical phenomena which must be taken into account to model the events that can occur. The adopted reliability calculations method is Monte Carlo simulations, the probabilistic method most powerful and most flexible to model complex operating of the distribution system. We devoted a first part on the case of a 20 kV feeder to which a cogeneration unit is connected. The method was applied to a software of stochastic Petri nets simulations. Then a second part related to the study of a low voltage power system supplied by dispersed generations. Here, the complexity of the events required to code the method in an environment of programming allowing the use of power system calculations (load flow, short-circuit, load shedding, management of units powers) in order to analyse the system state for each new event. (author)

  17. Relay Protection Coordination for Photovoltaic Power Plant Connected on Distribution Network

    OpenAIRE

    Nikolovski, Srete; Papuga, Vanja; Knežević, Goran

    2014-01-01

    This paper presents a procedure and computation of relay protection coordination for a PV power plant connected to the distribution network. In recent years, the growing concern for environment preservation has caused expansion of photovoltaic PV power plants in distribution networks. Numerical computer simulation is an indispensable tool for studying photovoltaic (PV) systems protection coordination. In this paper, EasyPower computer program is used with the module Power Protector. Time-curr...

  18. Future development of the electricity systems with distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Bayod-Rujula, Angel A. [Department of Electrical Engineering, Centro Politecnico Superior, University of Zaragoza, C/Maria de Luna, 3, 50018 Zaragoza (Spain)

    2009-03-15

    Electrical power systems have been traditionally designed taking energy from high-voltage levels, and distributing it to lower voltage level networks. There are large generation units connected to transmission networks. But in the future there will be a large number of small generators connected to the distribution networks. Efficient integration of this distributed generation requires network innovations. A development of active distribution network management, from centralised to more distributed system management, is needed. Information, communication, and control infrastructures will be needed with increasing complexity of system management. Some innovative concepts such as microgrids and virtual utilities will be presented. (author)

  19. Flocking of Second-Order Multiagent Systems With Connectivity Preservation Based on Algebraic Connectivity Estimation.

    Science.gov (United States)

    Fang, Hao; Wei, Yue; Chen, Jie; Xin, Bin

    2017-04-01

    The problem of flocking of second-order multiagent systems with connectivity preservation is investigated in this paper. First, for estimating the algebraic connectivity as well as the corresponding eigenvector, a new decentralized inverse power iteration scheme is formulated. Then, based on the estimation of the algebraic connectivity, a set of distributed gradient-based flocking control protocols is built with a new class of generalized hybrid potential fields which could guarantee collision avoidance, desired distance stabilization, and the connectivity of the underlying communication network simultaneously. What is important is that the proposed control scheme allows the existing edges to be broken without violation of connectivity constraints, and thus yields more flexibility of motions and reduces the communication cost for the multiagent system. In the end, nontrivial comparative simulations and experimental results are performed to demonstrate the effectiveness of the theoretical results and highlight the advantages of the proposed estimation scheme and control algorithm.

  20. Wind Power in Electrical Distribution Systems

    DEFF Research Database (Denmark)

    Chen, Zhe

    2013-01-01

    Recent years, wind power is experiencing a rapid growth, large number of wind turbines/wind farms have been installed and connected to power systems. In addition to the large centralised wind farms connected to transmission grids, many distributed wind turbines and wind farms are operated as dist...

  1. Evaluation small scale, grid connected wind and solar distributed generation systems in Jordan

    International Nuclear Information System (INIS)

    Naji, G. J.; Tahboub, K. K.; Jalham, I. S.

    2011-01-01

    In this paper, the potential of utilizing wind and solar Private Distributed Generation (PDG) for utility interactive systems is investigated for 11 selected stations (sites) in Jordan. Six customer categories are considered: residential, office, commercial mall, school, hospital and hotel. The main goal of this study was to evaluate the potential of utilizing different grid connected PDG under different conditions such as their location, size, served building category, number of people who share and own the equipment and system type whether wind, solar or hybrid based. It was found that solar systems are still not attractive for all location due to their associated high cost, while wind systems would vary widely depending on the customer category, location and the size of the equipment. Based on the Benefit to Cost ratio criterion, the most attractive sites for installing wind PDGS for residential communities are Ras Muneef, Mafraq, Aqaba, Irbid and H5, while it doesn't seem attractive at Amman,Shoubak, Ghor Essafi, Deir Alla, Maan and H4. On the other hand, the wind on-grid PDGS is very attractive at Ras Muneef, mafraq and Aqaba for commercial buildings, less attractive at H5 and irbid, while it's not attractive at the other sites. The attraction for hybrid PDG systems is closer to those of wind systems alone. (authors).

  2. Controlling Voltage Levels of Distribution Network-Radial Feeder after Connecting Wind Turbines to the Network

    Directory of Open Access Journals (Sweden)

    Muhammad Al Badri

    2017-11-01

    Full Text Available Several factors in power generation and supply need to be taken into account such as shortages of energy supply, system stability, and energy quality and system disruption due to network losses, industrial development and population expansion. The addition of wind turbines to the distribution network is of great benefit in providing additional power and solving these problems, but this addition is accompanied by the problem of low voltage network. This research found optimal solutions to the problem of low voltage distribution network after connecting wind turbines. The main idea of this paper is to optimize the low-voltage problem as a result of connecting the wind turbines to the "far end" of the radial feeder for a distribution network and to obtain a voltage level within an acceptable and stable range. The problem of low voltage solved by using the load-drop compensation, capacitor-bank and “doubly-fed” induction generators. The results of this study were based on the operation of the entire design of the simulation system which would be compatible with the reality of the energy flow of all network components by using the PSCAD program. The present analysis program revealed an optimum solution for the low voltage profile of the distribution network after connecting the wind turbine.

  3. Current Control and Performance Evaluation of Converter Interfaced Distribution Resources in Grid Connected Mode

    Directory of Open Access Journals (Sweden)

    SINGH Alka

    2012-10-01

    Full Text Available Use of distributed resources is growing in developing countries like India and in developed nations too. The increased acceptance of suchresources is mainly due to their modularity, increased reliability, good power quality and environment friendly operation. These are currently being interfaced to the existing systems using voltage source inverters (VSC’s. The control of such distributed resources is significantly different than the conventional power systems mainly because the VSC’s have no inertia unlike the synchronous generators.This paper deals with the Matlab modeling and design of control aspects of one such distributed source feeding a common load. A grid connected supply is also available. The control algorithm is developed for real and reactive power sharing of the load between thedistributed source and the grid. The developed control scheme is tested for linear (R-L load as well as nonlinear loads. With suitable modifications, the control algorithm can be extended for several distributed resources connected in parallel.

  4. Modeling and Control for Islanding Operation of Active Distribution Systems

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Wu, Qiuwei; Saleem, Arshad

    2011-01-01

    to stabilize the frequency. Different agents are defined to represent different resources in the distribution systems. A test platform with a real time digital simulator (RTDS), an OPen Connectivity (OPC) protocol server and the multi-agent based intelligent controller is established to test the proposed multi......Along with the increasing penetration of distributed generation (DG) in distribution systems, there are more resources for system operators to improve the operation and control of the whole system and enhance the reliability of electricity supply to customers. The distribution systems with DG...... are able to operate in is-landing operation mode intentionally or unintentionally. In order to smooth the transition from grid connected operation to islanding operation for distribution systems with DG, a multi-agent based controller is proposed to utilize different re-sources in the distribution systems...

  5. Identification of Synchronous Generator Electric Parameters Connected to the Distribution Grid

    Directory of Open Access Journals (Sweden)

    Frolov M. Yu.

    2017-04-01

    Full Text Available According to modern trends, the power grids with distributed generation will have an open system architecture. It means that active consumers, owners of distributed power units, including mobile units, must have free access to the grid, like when using internet, so it is necessary to have plug and play technologies. Thanks to them, the system will be able to identify the unit type and the unit parameters. Therefore, the main aim of research, described in the paper, was to develop and research a new method of electric parameters identification of synchronous generator. The main feature of the proposed method is that parameter identification is performed while the generator to the grid, so it fits in the technological process of operation of the machine and does not influence on the connection time of the machine. For the implementation of the method, it is not necessary to create dangerous operation modes for the machine or to have additional expensive equipment and it can be used for salient pole machines and round rotor machines. The parameter identification accuracy can be achieved by more accurate account of electromechanical transient process, and making of overdetermined system with many more numbers of equations. Parameter identification will be made with each generator connection to the grid. Comparing data obtained from each connection, the middle values can be find by numerical method, and thus, each subsequent identification will accurate the machine parameters.

  6. Hybrid solar lighting distribution systems and components

    Science.gov (United States)

    Muhs, Jeffrey D [Lenoir City, TN; Earl, Dennis D [Knoxville, TN; Beshears, David L [Knoxville, TN; Maxey, Lonnie C [Powell, TN; Jordan, John K [Oak Ridge, TN; Lind, Randall F [Lenoir City, TN

    2011-07-05

    A hybrid solar lighting distribution system and components having at least one hybrid solar concentrator, at least one fiber receiver, at least one hybrid luminaire, and a light distribution system operably connected to each hybrid solar concentrator and each hybrid luminaire. A controller operates all components.

  7. Internet and redefining tourism distribution system

    Directory of Open Access Journals (Sweden)

    Đelić Tanja

    2004-01-01

    Full Text Available Since the introduction, computerized systems that manage reservation systems, rapidly became inevitable distribution channel for all service companies in tourist industry. GDS in reality using communication network connects service offer, selling personnel and air companies.

  8. Quantitative Analysis Method of Output Loss due to Restriction for Grid-connected PV Systems

    Science.gov (United States)

    Ueda, Yuzuru; Oozeki, Takashi; Kurokawa, Kosuke; Itou, Takamitsu; Kitamura, Kiyoyuki; Miyamoto, Yusuke; Yokota, Masaharu; Sugihara, Hiroyuki

    Voltage of power distribution line will be increased due to reverse power flow from grid-connected PV systems. In the case of high density grid connection, amount of voltage increasing will be higher than the stand-alone grid connection system. To prevent the over voltage of power distribution line, PV system's output will be restricted if the voltage of power distribution line is close to the upper limit of the control range. Because of this interaction, amount of output loss will be larger in high density case. This research developed a quantitative analysis method for PV systems output and losses to clarify the behavior of grid connected PV systems. All the measured data are classified into the loss factors using 1 minute average of 1 second data instead of typical 1 hour average. Operation point on the I-V curve is estimated to quantify the loss due to the output restriction using module temperature, array output voltage, array output current and solar irradiance. As a result, loss due to output restriction is successfully quantified and behavior of output restriction is clarified.

  9. Synchronization Methods for Three Phase Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian Vasile; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    Nowadays, it is a general trend to increase the electricity production using Distributed Power Generation Systems (DPGS) based on renewable energy resources such as wind, sun or hydrogen. If these systems are not properly controlled, their connection to the utility network can generate problems...... on the grid side. Therefore, considerations about power generation, safe running and grid synchronization must be done before connecting these systems to the utility network. This paper is mainly dealing with the grid synchronization issues of distributed systems. An overview of the synchronization methods...

  10. A new HBMO algorithm for multiobjective daily Volt/Var control in distribution systems considering Distributed Generators

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, Taher [Electrical and Electronics Engineering Department, Shiraz University of Technology, Modars Blvd. P.O. 71555-313, Shiraz (Iran, Islamic Republic of)

    2011-03-15

    In recent years, Distributed Generators (DGs) connected to the distribution network have received increasing attention. The connection of enormous DGs into existing distribution network changes the operation of distribution systems. Because of the small X/R ratio and radial structure of distribution systems, DGs affect the daily Volt/Var control. This paper presents a new algorithm for multiobjective daily Volt/Var control in distribution systems including Distributed Generators (DGs). The objectives are costs of energy generation by DGs and distribution companies, electrical energy losses and the voltage deviations for the next day. A new optimization algorithm based on a Chaotic Improved Honey Bee Mating Optimization (CIHBMO) is proposed to determine the active power values of DGs, reactive power values of capacitors and tap positions of transformers for the next day. Since objectives are not the same, a fuzzy system is used to calculate the best solution. The plausibility of the proposed algorithm is demonstrated and its performance is compared with other methods on a 69-bus distribution feeder. Simulation results illustrate that the proposed algorithm has better outperforms the other algorithms. (author)

  11. A new HBMO algorithm for multiobjective daily Volt/Var control in distribution systems considering Distributed Generators

    International Nuclear Information System (INIS)

    Niknam, Taher

    2011-01-01

    In recent years, Distributed Generators (DGs) connected to the distribution network have received increasing attention. The connection of enormous DGs into existing distribution network changes the operation of distribution systems. Because of the small X/R ratio and radial structure of distribution systems, DGs affect the daily Volt/Var control. This paper presents a new algorithm for multiobjective daily Volt/Var control in distribution systems including Distributed Generators (DGs). The objectives are costs of energy generation by DGs and distribution companies, electrical energy losses and the voltage deviations for the next day. A new optimization algorithm based on a Chaotic Improved Honey Bee Mating Optimization (CIHBMO) is proposed to determine the active power values of DGs, reactive power values of capacitors and tap positions of transformers for the next day. Since objectives are not the same, a fuzzy system is used to calculate the best solution. The plausibility of the proposed algorithm is demonstrated and its performance is compared with other methods on a 69-bus distribution feeder. Simulation results illustrate that the proposed algorithm has better outperforms the other algorithms.

  12. Archtecture of distributed real-time systems

    OpenAIRE

    Wing Leung, Cheuk

    2013-01-01

    CRAFTERS (Constraint and Application Driven Framework for Tailoring Embedded Real-time System) project aims to address the problem of uncertainty and heterogeneity in a distributed system by providing seamless, portable connectivity and middleware. This thesis contributes to the project by investigating the techniques that can be used in a distributed real-time embedded system. The conclusion is that, there is a list of specifications to be meet in order to provide a transparent and real-time...

  13. Analysis of distribution systems with a high penetration of distributed generation

    DEFF Research Database (Denmark)

    Lund, Torsten

    Since the mid eighties, a large number of wind turbines and distributed combined heat and power plants (CHPs) have been connected to the Danish power system. Especially in the Western part, comprising Jutland and Funen, the penetration is high compared to the load demand. In some periods the wind...... power alone can cover the entire load demand. The objective of the work is to investigate the influence of wind power and distributed combined heat and power production on the operation of the distribution systems. Where other projects have focused on the modeling and control of the generators and prime...... movers, the focus of this project is on the operation of an entire distribution system with several wind farms and CHPs. Firstly, the subject of allocation of power system losses in a distribution system with distributed generation is treated. A new approach to loss allocation based on current injections...

  14. Accelerated Distributed Dual Averaging Over Evolving Networks of Growing Connectivity

    Science.gov (United States)

    Liu, Sijia; Chen, Pin-Yu; Hero, Alfred O.

    2018-04-01

    We consider the problem of accelerating distributed optimization in multi-agent networks by sequentially adding edges. Specifically, we extend the distributed dual averaging (DDA) subgradient algorithm to evolving networks of growing connectivity and analyze the corresponding improvement in convergence rate. It is known that the convergence rate of DDA is influenced by the algebraic connectivity of the underlying network, where better connectivity leads to faster convergence. However, the impact of network topology design on the convergence rate of DDA has not been fully understood. In this paper, we begin by designing network topologies via edge selection and scheduling. For edge selection, we determine the best set of candidate edges that achieves the optimal tradeoff between the growth of network connectivity and the usage of network resources. The dynamics of network evolution is then incurred by edge scheduling. Further, we provide a tractable approach to analyze the improvement in the convergence rate of DDA induced by the growth of network connectivity. Our analysis reveals the connection between network topology design and the convergence rate of DDA, and provides quantitative evaluation of DDA acceleration for distributed optimization that is absent in the existing analysis. Lastly, numerical experiments show that DDA can be significantly accelerated using a sequence of well-designed networks, and our theoretical predictions are well matched to its empirical convergence behavior.

  15. Electric distribution systems and embedded generation capacity

    International Nuclear Information System (INIS)

    Calderaro, V.; Galdi, V.; Piccolo, A.; Siano, P.

    2006-01-01

    The main policy issues of European States are sustainable energy supply promotion and liberalization of energy markets, which introduced market competition in electricity production and created support mechanisms to encourage renewable electricity production and consumption. As a result of liberalization, any generator, including small-scale and renewable energy based units, can sell electricity on the free market. In order to meet future sustainability targets, connection of a higher number of Distributed Generation (DG) units to the electrical power system is expected, requiring changes in the design and operation of distribution electricity systems, as well as changes in electricity network regulation. In order to assist distribution system operators in planning and managing DG connections and in maximizing DG penetration and renewable sources exploitation, this paper proposed a reconfiguration methodology based on a Genetic Algorithm (GA), that was tested on a 70-bus system with DG units. The simulation results confirmed that the methodology represents a suitable tool for distribution system operators when dealing with DG capacity expansion and power loss issues, providing information regarding the potential penetration network-wide and allowing maximum exploitation of renewable generation. 35 refs., 4 tabs., 6 figs

  16. Rigorous Results for the Distribution of Money on Connected Graphs

    Science.gov (United States)

    Lanchier, Nicolas; Reed, Stephanie

    2018-05-01

    This paper is concerned with general spatially explicit versions of three stochastic models for the dynamics of money that have been introduced and studied numerically by statistical physicists: the uniform reshuffling model, the immediate exchange model and the model with saving propensity. All three models consist of systems of economical agents that consecutively engage in pairwise monetary transactions. Computer simulations performed in the physics literature suggest that, when the number of agents and the average amount of money per agent are large, the limiting distribution of money as time goes to infinity approaches the exponential distribution for the first model, the gamma distribution with shape parameter two for the second model and a distribution similar but not exactly equal to a gamma distribution whose shape parameter depends on the saving propensity for the third model. The main objective of this paper is to give rigorous proofs of these conjectures and also extend these conjectures to generalizations of the first two models and a variant of the third model that include local rather than global interactions, i.e., instead of choosing the two interacting agents uniformly at random from the system, the agents are located on the vertex set of a general connected graph and can only interact with their neighbors.

  17. Combined Use of Systematic Conservation Planning, Species Distribution Modelling, and Connectivity Analysis Reveals Severe Conservation Gaps in a Megadiverse Country (Peru)

    Science.gov (United States)

    Fajardo, Javier; Lessmann, Janeth; Bonaccorso, Elisa; Devenish, Christian; Muñoz, Jesús

    2014-01-01

    Conservation planning is crucial for megadiverse countries where biodiversity is coupled with incomplete reserve systems and limited resources to invest in conservation. Using Peru as an example of a megadiverse country, we asked whether the national system of protected areas satisfies biodiversity conservation needs. Further, to complement the existing reserve system, we identified and prioritized potential conservation areas using a combination of species distribution modeling, conservation planning and connectivity analysis. Based on a set of 2,869 species, including mammals, birds, amphibians, reptiles, butterflies, and plants, we used species distribution models to represent species' geographic ranges to reduce the effect of biased sampling and partial knowledge about species' distributions. A site-selection algorithm then searched for efficient and complementary proposals, based on the above distributions, for a more representative system of protection. Finally, we incorporated connectivity among areas in an innovative post-hoc analysis to prioritize those areas maximizing connectivity within the system. Our results highlight severe conservation gaps in the Coastal and Andean regions, and we propose several areas, which are not currently covered by the existing network of protected areas. Our approach helps to find areas that contribute to creating a more representative, connected and efficient network. PMID:25479411

  18. Online Energy Management System for Distributed Generators in a Grid-Connected Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises

    2015-01-01

    A microgrid is an energy subsystem composed of generation units, energy storage, and loads that requires power management in order to supply the load properly according to defined objectives. This paper proposes an online energy management system for a storage based grid-connected microgrid...

  19. Specification of a system for planning and analysis of independent generator connection impact on the electric distribution system; Especificacao de um sistema de planeamento e analise do impacto da conexao de geradores independentes no sistema electrico da distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Proenca, Luis Miguel; Matos, Manuel Antonio [Instituto de Engenharia de Sistemas e Computadores (INESC), Porto (Portugal); Campos, Manuel Luis Borges [Centro para a Excelencia na Distribuicao (CED), Sao Paulo, SP (Brazil)

    1999-07-01

    This paper describes a system for planning and analysis of the independent generator connection impact on the electric distribution system. This system is being developed under a contract signed between the Center for Excellency in the Distribution (CED), state of Sao Paulo - Brazil and the INESC, Porto - Portugal - energy unit.

  20. Distributed redundancy and robustness in complex systems

    KAUST Repository

    Randles, Martin

    2011-03-01

    The uptake and increasing prevalence of Web 2.0 applications, promoting new large-scale and complex systems such as Cloud computing and the emerging Internet of Services/Things, requires tools and techniques to analyse and model methods to ensure the robustness of these new systems. This paper reports on assessing and improving complex system resilience using distributed redundancy, termed degeneracy in biological systems, to endow large-scale complicated computer systems with the same robustness that emerges in complex biological and natural systems. However, in order to promote an evolutionary approach, through emergent self-organisation, it is necessary to specify the systems in an \\'open-ended\\' manner where not all states of the system are prescribed at design-time. In particular an observer system is used to select robust topologies, within system components, based on a measurement of the first non-zero Eigen value in the Laplacian spectrum of the components\\' network graphs; also known as the algebraic connectivity. It is shown, through experimentation on a simulation, that increasing the average algebraic connectivity across the components, in a network, leads to an increase in the variety of individual components termed distributed redundancy; the capacity for structurally distinct components to perform an identical function in a particular context. The results are applied to a specific application where active clustering of like services is used to aid load balancing in a highly distributed network. Using the described procedure is shown to improve performance and distribute redundancy. © 2010 Elsevier Inc.

  1. On Modelling Real-time and Security properties of Distributed Systems

    NARCIS (Netherlands)

    Corin, Ricardo; Etalle, Sandro; Hartel, Pieter H.; Mader, Angelika H.

    2003-01-01

    We discuss a simplified version of the timing attack to illustrate a connection between security and real-time properties of distributed systems. We suggest several avenues for further research on this and similar connections.

  2. A multi-objective control strategy for grid connection of DG (distributed generation) resources

    Energy Technology Data Exchange (ETDEWEB)

    Pouresmaeil, Edris; Montesinos-Miracle, Daniel; Bergas-Jane, Joan [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Departament d' Enginyeria Electrica, Universitat Politecnica de Catalunya, ETS d' Enginyeria Industrial de Barcelona (Spain); Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Departament d' Enginyeria Electrica, Universitat Politecnica de Catalunya, ETS d' Enginyeria Industrial de Barcelona (Spain); Catalonia Institute for Energy Research IREC, Barcelona (Spain)

    2010-12-15

    This paper presents a flexible control technique for connection of DG (distributed generation) resources to distribution networks, especially during ride-through on faulty grid. This strategy is derived from the abc/{alpha}{beta} and {alpha}{beta}/dq transformations of the ac system variables. The active and reactive currents injected by the DG source are controlled in the synchronously rotating orthogonal dq reference frame. The transformed variables are used to control the VSI (voltage source inverter) which connects the DG to the distribution network. Using a P.L.L. (phase locked loop) in circuit of proposed control technique, the angle of positive sequence has been detected, in order to synchronize the currents to the distribution network. The proposed control technique has the capability of providing active and reactive powers and harmonic currents to nonlinear loads with a fast dynamic response. Simulation results and mathematical analysis have been completed in order to achieve a reduced THD (total harmonic distortion), increased power factor and compensated load's active and reactive powers. The analyses show the high performance of this control strategy in DG applications in comparison with other existing strategies. (author)

  3. Reliability analysis of water distribution systems under uncertainty

    International Nuclear Information System (INIS)

    Kansal, M.L.; Kumar, Arun; Sharma, P.B.

    1995-01-01

    In most of the developing countries, the Water Distribution Networks (WDN) are of intermittent type because of the shortage of safe drinking water. Failure of a pipeline(s) in such cases will cause not only the fall in one or more nodal heads but also the poor connectivity of source with various demand nodes of the system. Most of the previous works have used the two-step algorithm based on pathset or cutset approach for connectivity analysis. The computations become more cumbersome when connectivity of all demand nodes taken together with that of supply is carried out. In the present paper, network connectivity based on the concept of Appended Spanning Tree (AST) is suggested to compute global network connectivity which is defined as the probability of the source node being connected with all the demand nodes simultaneously. The concept of AST has distinct advantages as it attacks the problem directly rather than in an indirect way as most of the studies so far have done. Since the water distribution system is a repairable one, a general expression for pipeline avialability using the failure/repair rate is considered. Furthermore, the sensitivity of global reliability estimates due to the likely error in the estimation of failure/repair rates of various pipelines is also studied

  4. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional-integral, proportio......This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional......-integral, proportional-resonant, and deadbeat (DB) controllers. Additionally, an improved DB controller robust against grid impedance variation is also presented. Since the paper discusses the implementation of these controllers for grid-connected applications, their evaluation is made in three operating conditions....... First, in steady-state conditions, the contribution of controllers to the total harmonic distortion of the grid current is pursued. Further on, the behavior of controllers in the case of transient conditions like input power variations and grid voltage faults is also examined. Experimental results...

  5. GPCALMA: A Tool For Mammography With A GRID-Connected Distributed Database

    International Nuclear Information System (INIS)

    Bottigli, U.; Golosio, B.; Masala, G.L.; Oliva, P.; Stumbo, S.; Cerello, P.; Cheran, S.; Delogu, P.; Fantacci, M.E.; Retico, A.; Fauci, F.; Magro, R.; Raso, G.; Lauria, A.; Palmiero, R.; Lopez Torres, E.; Tangaro, S.

    2003-01-01

    The GPCALMA (Grid Platform for Computer Assisted Library for MAmmography) collaboration involves several departments of physics, INFN (National Institute of Nuclear Physics) sections, and italian hospitals. The aim of this collaboration is developing a tool that can help radiologists in early detection of breast cancer. GPCALMA has built a large distributed database of digitised mammographic images (about 5500 images corresponding to 1650 patients) and developed a CAD (Computer Aided Detection) software which is integrated in a station that can also be used to acquire new images, as archive and to perform statistical analysis. The images (18x24 cm2, digitised by a CCD linear scanner with a 85 μm pitch and 4096 gray levels) are completely described: pathological ones have a consistent characterization with radiologist's diagnosis and histological data, non pathological ones correspond to patients with a follow up at least three years. The distributed database is realized through the connection of all the hospitals and research centers in GRID technology. In each hospital local patients digital images are stored in the local database. Using GRID connection, GPCALMA will allow each node to work on distributed database data as well as local database data. Using its database the GPCALMA tools perform several analysis. A texture analysis, i.e. an automated classification on adipose, dense or glandular texture, can be provided by the system. GPCALMA software also allows classification of pathological features, in particular massive lesions (both opacities and spiculated lesions) analysis and microcalcification clusters analysis. The detection of pathological features is made using neural network software that provides a selection of areas showing a given 'suspicion level' of lesion occurrence. The performance of the GPCALMA system will be presented in terms of the ROC (Receiver Operating Characteristic) curves. The results of GPCALMA system as 'second reader' will also

  6. Self-Tuning Fully-Connected PID Neural Network System for Distributed Temperature Sensing and Control of Instrument with Multi-Modules.

    Science.gov (United States)

    Zhang, Zhen; Ma, Cheng; Zhu, Rong

    2016-10-14

    High integration of multi-functional instruments raises a critical issue in temperature control that is challenging due to its spatial-temporal complexity. This paper presents a multi-input multi-output (MIMO) self-tuning temperature sensing and control system for efficiently modulating the temperature environment within a multi-module instrument. The smart system ensures that the internal temperature of the instrument converges to a target without the need of a system model, thus making the control robust. The system consists of a fully-connected proportional-integral-derivative (PID) neural network (FCPIDNN) and an on-line self-tuning module. The experimental results show that the presented system can effectively control the internal temperature under various mission scenarios, in particular, it is able to self-reconfigure upon actuator failure. The system provides a new scheme for a complex and time-variant MIMO control system which can be widely applied for the distributed measurement and control of the environment in instruments, integration electronics, and house constructions.

  7. Self-Tuning Fully-Connected PID Neural Network System for Distributed Temperature Sensing and Control of Instrument with Multi-Modules

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2016-10-01

    Full Text Available High integration of multi-functional instruments raises a critical issue in temperature control that is challenging due to its spatial–temporal complexity. This paper presents a multi-input multi-output (MIMO self-tuning temperature sensing and control system for efficiently modulating the temperature environment within a multi-module instrument. The smart system ensures that the internal temperature of the instrument converges to a target without the need of a system model, thus making the control robust. The system consists of a fully-connected proportional–integral–derivative (PID neural network (FCPIDNN and an on-line self-tuning module. The experimental results show that the presented system can effectively control the internal temperature under various mission scenarios, in particular, it is able to self-reconfigure upon actuator failure. The system provides a new scheme for a complex and time-variant MIMO control system which can be widely applied for the distributed measurement and control of the environment in instruments, integration electronics, and house constructions.

  8. Assessment of detection limits of fiber-optic distributed temperature sensing for detection of illicit connections

    NARCIS (Netherlands)

    Nienhuis, J.; De Haan, C.; Langeveld, J.G.; Klootwijk, M.; Clemens, F.H.L.R.

    2012-01-01

    Distributed Temperature Sensing (DTS) with fiber-optic cables is a powerful tool to detect illicit connections in storm sewer systems. High frequency temperature measurements along the in-sewer cable create a detailed representation of temperature anomalies due to illicit discharges. The detection

  9. Rendezvous with connectivity preservation for multi-robot systems with an unknown leader

    Science.gov (United States)

    Dong, Yi

    2018-02-01

    This paper studies the leader-following rendezvous problem with connectivity preservation for multi-agent systems composed of uncertain multi-robot systems subject to external disturbances and an unknown leader, both of which are generated by a so-called exosystem with parametric uncertainty. By combining internal model design, potential function technique and adaptive control, two distributed control strategies are proposed to maintain the connectivity of the communication network, to achieve the asymptotic tracking of all the followers to the output of the unknown leader system, as well as to reject unknown external disturbances. It is also worth to mention that the uncertain parameters in the multi-robot systems and exosystem are further allowed to belong to unknown and unbounded sets when applying the second fully distributed control law containing a dynamic gain inspired by high-gain adaptive control or self-tuning regulator.

  10. A Modeling Framework for Schedulability Analysis of Distributed Avionics Systems

    DEFF Research Database (Denmark)

    Han, Pujie; Zhai, Zhengjun; Nielsen, Brian

    2018-01-01

    This paper presents a modeling framework for schedulability analysis of distributed integrated modular avionics (DIMA) systems that consist of spatially distributed ARINC-653 modules connected by a unified AFDX network. We model a DIMA system as a set of stopwatch automata (SWA) in UPPAAL...

  11. Three-Dimensional Finite Element Analysis of the Stress Distribution at the Internal Implant-Abutment Connection.

    Science.gov (United States)

    Cho, Sung-Yong; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2016-01-01

    This study investigated stress distribution in four different implant-abutment interface conditions in the internal tapered connection implant system. Four different implant diameters (3.5 mm, 4.0 mm, 4.5 mm, and 5.0 mm) and two abutment types (hexagonal and conical) were simulated. Four unique implant-abutment interface conditions were assumed based on wall thickness, mating surface length, distance to the vertical stop, and abutment shape. Axial and oblique loading was applied during abutment screw preload, and the Von Mises stresses were measured at the implant-abutment and abutment-screw interfaces. The implant-abutment interface stress decreased as the wall thickness increased. As the mating surface increased, the stress distribution trended downward, and when the distance to the implant vertical stop was 0 μm, the Von Mises stress was extremely high at the vertical stop. Despite their different shapes, the abutments showed similar stress distributions. However, the maximum Von Mises stress was higher in the conical connection than in the hexagonal connection, particularly at the contralateral side to loading. To decrease the stress distribution at the implant-abutment interface, the implant wall thickness, mating surface contact length, distance to the vertical stop, and abutment shape should be carefully considered.

  12. A role for distributed processing in advanced nuclear materials control and accountability systems

    International Nuclear Information System (INIS)

    Tisinger, R.M.; Whitty, W.J.; Ford, W.; Strittmatter, R.B.

    1986-01-01

    Networking and distributed processing hardware and software have the potential of greatly enhancing nuclear materials control and account-ability (MCandA) systems, both from safeguards and process operations perspectives while allowing timely integrated safeguards activities and enhanced computer security at reasonable cost. A hierarchical distributed system is proposed consisting of groups of terminals and instruments in plant production and support areas connected to microprocessors that are connected to either larger microprocessors or minicomputers. The structuring and development of a limited distributed MCandA prototype system, including human engineering concepts, are described. Implications of integrated safeguards and computer security concepts to the distributed system design are discussed

  13. Development of distributed measurement and control systems for application in electrical energy systems

    Directory of Open Access Journals (Sweden)

    Gajić Tomislav

    2013-01-01

    Full Text Available In this paper LPC1766 microcontroller based network capable application processor (NCAP system, is described. This system is intended to be used in modern distributed control and monitoring systems for application in power plants and industry, as well as in modern electricity distribution networks. In order to do that it is necessary to analyze different aspects of the system, like signal processing part or communication requirements. The chosen microcontroller has enough resources to satisfy requirements of an transducer interface module (TIM. Beside the realization of NCAp and TIM controllers it is necessary to develop the necessary measurement modules, in order to realize measurement-control systems. The developed layout could be connected to actuators to the local area network (LAN, as well. If the local LAN is connected to the internet it is possible to monitor and configure measurement modules form the remote site. Having in mind the growing complexity in control systems, it has been a real challenge to detect a diagnose problems in today's large scale distributed systems. Implementation of the proposed module could potentially reduce the time necessary to extract necessary information from the abundant quantity of information that are usually provided by the complex distributed systems.

  14. Fluid moderator control system reactor internals distribution system

    International Nuclear Information System (INIS)

    Fensterer, H.F.; Klassen, W.E.; Veronesi, L.; Boyle, D.E.; Salton, R.B.

    1987-01-01

    This patent describes a spectral shift pressurized water nuclear reactor employing a low neutron moderating fluid for the spectral shift including a reactor pressure vessel, a core comprising a plurality of fuel assemblies, a core support plate, apparatus comprising means for penetrating the reactor vessel for introducing the moderating fluid into the reactor vessel. Means associated with the core support plate for directly distributing the moderating fluid to and from the fuel assemblies comprises at least one inlet flow channel in the core plate; branch inlet feed lines connect to the inlet flow channel in the core plate; vertical inlet flow lines flow connected to the branch inlet feed lines; each vertical flow line communicates with a fuel assembly; the distribution means further comprise lines serving as return flow lines, each of which is connected to one of the fuel assemblies; branch exit flow lines in the core plate flow connected to the return flow lines of the fuel assembly; and at least one outlet flow channel flow connected to the branch exit flow lines; and a flow port interposed between the penetration means and the distribution means for flow connecting the penetration means with the distribution means

  15. Gas turbine control for islanding operation of distribution systems

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2009-01-01

    Danish distribution systems are characterized by a significant penetration of small gas turbine generators (GTGs) and fixed speed wind turbine generators (WTGs). Island operation of these distribution systems are becoming a viable option for economical and technical reasons. However, stabilizing...... frequency in an islanded system is one of the major challenges. This paper presents three different gas turbine governors for possible operation of distribution systems in an islanding mode. Simulation results are presented to show the performance of these governors in grid connected and islanding mode....

  16. Organization of the secure distributed computing based on multi-agent system

    Science.gov (United States)

    Khovanskov, Sergey; Rumyantsev, Konstantin; Khovanskova, Vera

    2018-04-01

    Nowadays developing methods for distributed computing is received much attention. One of the methods of distributed computing is using of multi-agent systems. The organization of distributed computing based on the conventional network computers can experience security threats performed by computational processes. Authors have developed the unified agent algorithm of control system of computing network nodes operation. Network PCs is used as computing nodes. The proposed multi-agent control system for the implementation of distributed computing allows in a short time to organize using of the processing power of computers any existing network to solve large-task by creating a distributed computing. Agents based on a computer network can: configure a distributed computing system; to distribute the computational load among computers operated agents; perform optimization distributed computing system according to the computing power of computers on the network. The number of computers connected to the network can be increased by connecting computers to the new computer system, which leads to an increase in overall processing power. Adding multi-agent system in the central agent increases the security of distributed computing. This organization of the distributed computing system reduces the problem solving time and increase fault tolerance (vitality) of computing processes in a changing computing environment (dynamic change of the number of computers on the network). Developed a multi-agent system detects cases of falsification of the results of a distributed system, which may lead to wrong decisions. In addition, the system checks and corrects wrong results.

  17. Automatic radiation measuring system connected with GPS

    International Nuclear Information System (INIS)

    Tanigaki, Minoru

    2014-01-01

    The most serious nuclear disaster in Japan has broken out at Fukushima Daiichi Nuclear Power Plant due to Great East Japan Earthquake. Prompt and exact mapping of the contamination is of great importance for radiation protection and for the environment restoration. We have developed radiation survey systems KURAMA and KURAMA-2 for rapid and exact measurement of radiation dose distribution. The system is composed of a mobile radiation monitor and the computer in office which is for the storage and visualization of the data. They are connected with internet and are operated for continuous radiation measurement while the monitor is moving. The mobile part consists of a survey meter, an interface to transform the output of the survey meter for the computer, a global positioning system, a computer to process the data for connecting to the network, and a mobile router. Thus they are effective for rapid mapping of the surface contamination. The operation and the performance of the equipment at the site are presented. (J.P.N.)

  18. Reliable file sharing in distributed operating system using web RTC

    Science.gov (United States)

    Dukiya, Rajesh

    2017-12-01

    Since, the evolution of distributed operating system, distributed file system is come out to be important part in operating system. P2P is a reliable way in Distributed Operating System for file sharing. It was introduced in 1999, later it became a high research interest topic. Peer to Peer network is a type of network, where peers share network workload and other load related tasks. A P2P network can be a period of time connection, where a bunch of computers connected by a USB (Universal Serial Bus) port to transfer or enable disk sharing i.e. file sharing. Currently P2P requires special network that should be designed in P2P way. Nowadays, there is a big influence of browsers in our life. In this project we are going to study of file sharing mechanism in distributed operating system in web browsers, where we will try to find performance bottlenecks which our research will going to be an improvement in file sharing by performance and scalability in distributed file systems. Additionally, we will discuss the scope of Web Torrent file sharing and free-riding in peer to peer networks.

  19. Identification of Requirements for Distribution Management Systems in the Smart Grid Context

    DEFF Research Database (Denmark)

    Rezkalla, Michel M.N.; Heussen, Kai; Marinelli, Mattia

    2015-01-01

    The integration of significant volumes of distributed and renewable energy resources directly connected to the distribution network raises new requirement to maintain and operate the power system in secure state. Thus the Distribution Management System (DMS) needs to be updated and integrated...

  20. Protection of Distribution Systems with Distributed Energy Resources

    DEFF Research Database (Denmark)

    Bak-Jensen, Birgitte; Browne, Matthew; Calone, Roberto

    of 17 months of work of the Joint Working Group B5/C6.26/CIRED “Protection of Distribution Systems with Distributed Energy Resources”. The working group used the CIGRE report TB421 “The impact of Renewable Energy Sources and Distributed Generation on Substation Protection and Automation”, published...... by WG B5.34 as the entry document for the work on this report. In doing so, the group aligned the content and the scope of this report, the network structures considered, possible islanding, standardized communication and adaptive protection, interface protection, connection schemes and protection...... are listed (chapter 3). The first main part of the report starts with a summary of the backgrounds on DER and current practices in protection at the distribution level (chapter 4). This chapter contains an analysis of CIGRE TB421, protection relevant characteristics of DER, a review of current practices...

  1. A current controller of grid-connected converter for harmonic damping in a distribution network

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2011-01-01

    Harmonic resonance caused by the increased use of shunt-connected capacitors in LCL-filters and power factor correction devices may become a serious power quality challenge in electric distribution systems. A voltage-detection method based on current control is developed to damp harmonic resonances....... However, it is susceptible to the mismatch between harmonic conductance and characteristic impedance of distribution feeder. This paper proposes a current controller which allows discrete adjustment of harmonic conductance for both the characteristic harmonic and the non-characteristic harmonic voltages...

  2. Expected Range of Cooperation Between Transmission System Operators and Distribution System Operators After Implementation of ENTSO-E Grid Codes

    Directory of Open Access Journals (Sweden)

    Tomasz Pakulski

    2015-06-01

    Full Text Available The authors present the prospects of cooperation between transmission system operators (TSO and distribution system operators (DSO after entry into force ENTSO-E (European Network of Transmission System Operators for Electricity grid codes. New areas of DSO activities, associated with offering TSO aggregated services for national power system regulation based on the regulation resources connected to the distribution grid, and services on the distribution system level as part of the creation of local balancing areas (LBA are presented. The paper also presents the possibilities of providing ancillary services by different types of distributed generation sources in the distribution network. The LBA concept, which involves integrated management of local regulation resources including generation, demand, and energy storage is described. The options of the renewable energy sources (RES using for voltage and reactive power control in the distribution network with the use of wind farms (WF connected to the distribution system are characterized.

  3. Laser spark distribution and ignition system

    Science.gov (United States)

    Woodruff, Steven [Morgantown, WV; McIntyre, Dustin L [Morgantown, WV

    2008-09-02

    A laser spark distribution and ignition system that reduces the high power optical requirements for use in a laser ignition and distribution system allowing for the use of optical fibers for delivering the low peak energy pumping pulses to a laser amplifier or laser oscillator. An optical distributor distributes and delivers optical pumping energy from an optical pumping source to multiple combustion chambers incorporating laser oscillators or laser amplifiers for inducing a laser spark within a combustion chamber. The optical distributor preferably includes a single rotating mirror or lens which deflects the optical pumping energy from the axis of rotation and into a plurality of distinct optical fibers each connected to a respective laser media or amplifier coupled to an associated combustion chamber. The laser spark generators preferably produce a high peak power laser spark, from a single low power pulse. The laser spark distribution and ignition system has application in natural gas fueled reciprocating engines, turbine combustors, explosives and laser induced breakdown spectroscopy diagnostic sensors.

  4. Facilitate generation connections on Orkney by automatic distribution network management

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This report summarises the results of a study assessing the capability and limitations of the Orkney Network under a variety of conditions of demand, generation connections, network configuration, and reactive compensation). A conceptual active management scheme (AMS) suitable for the conditions on Orkney is developed and evaluated. Details are given of a proposed framework for the design and evaluation of future active management schemes, logic control sequences for managed generation units, and a proposed evaluation method for the active management scheme. Implications of introducing the proposed AMS are examined, and the commercial aspects of an AMS and system security are considered. The existing Orkney network is described; and an overview of the SHEPDL (Scottish Hydro Electric Power Distribution Ltd.) SCADA system is presented with a discussion of AMS identification, selection, and development.

  5. Distributed Cognition on the road: Using EAST to explore future road transportation systems.

    Science.gov (United States)

    Banks, Victoria A; Stanton, Neville A; Burnett, Gary; Hermawati, Setia

    2018-04-01

    Connected and Autonomous Vehicles (CAV) are set to revolutionise the way in which we use our transportation system. However, we do not fully understand how the integration of wireless and autonomous technology into the road transportation network affects overall network dynamism. This paper uses the theoretical principles underlying Distributed Cognition to explore the dependencies and interdependencies that exist between system agents located within the road environment, traffic management centres and other external agencies in both non-connected and connected transportation systems. This represents a significant step forward in modelling complex sociotechnical systems as it shows that the principles underlying Distributed Cognition can be applied to macro-level systems using the visual representations afforded by the Event Analysis of Systemic Teamwork (EAST) method. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A distribution-oriented approach to support landscape connectivity for ecologically distinct bird species.

    Science.gov (United States)

    Herrera, José M; Alagador, Diogo; Salgueiro, Pedro; Mira, António

    2018-01-01

    Managing landscape connectivity is a widely recognized overarching strategy for conserving biodiversity in human-impacted landscapes. However, planning the conservation and management of landscape connectivity of multiple and ecologically distinct species is still challenging. Here we provide a spatially-explicit framework which identifies and prioritizes connectivity conservation and restoration actions for species with distinct habitat affinities. Specifically, our study system comprised three groups of common bird species, forest-specialists, farmland-specialists, and generalists, populating a highly heterogeneous agricultural countryside in the southwestern Iberian Peninsula. We first performed a comprehensive analysis of the environmental variables underlying the distributional patterns of each bird species to reveal generalities in their guild-specific responses to landscape structure. Then, we identified sites which could be considered pivotal in maintaining current levels of landscape connectivity for the three bird guilds simultaneously, as well as the number and location of sites that need to be restored to maximize connectivity levels. Interestingly, we found that a small number of sites defined the shortest connectivity paths for the three bird guilds simultaneously, and were therefore considered key for conservation. Moreover, an even smaller number of sites were identified as critical to expand the landscape connectivity at maximum for the regional bird assemblage as a whole. Our spatially-explicit framework can provide valuable decision-making support to conservation practitioners aiming to identify key connectivity and restoration sites, a particularly urgent task in rapidly changing landscapes such as agroecosystems.

  7. Network connection of distributed electricity production - a preliminary study

    International Nuclear Information System (INIS)

    Pleym, Anngjerd; Mogstad, Olve

    2002-01-01

    It will be necessary to lower the barriers for utilisation of distributed energy sources in order to increase the use of such sources in Norway. A relatively extensive R and D activity would be required for reaching this goal. Available Norwegian and international guidelines and technical requirements with respect to network connection of the distributed energy sources are studied with the aim of exposing needs for further R and D initiatives. A limited monitor is also carried out among the Norwegian network businesses with distributed units in their networks. The results show that the main focus in the R and D activities has drifted away from establishing guidelines for technical requirements for network coupling. Some verification work remains in investigating the usefulness of the existing international and the specific commercial network guidelines. For the network industry the main focus must be on the two following areas: 1) How will large concentrations of distributed production units connected to the same network influence the voltage quality and the delivery reliability in the networks. 2) How can the network businesses employ the distributed production units in their networks. A Nordic project (Finland, Sweden, Norway) which will study these problems is being established. Large national scientific institutions will be involved. The executive committee will consist of representatives from Finenergy, Elforsk and EBL Kompetanse and other financing institutions and industries. A Finnish business Merinova, is to be appointed to the project leadership

  8. Distributed Energy Resources Interconnection Systems: Technology Review and Research Needs

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, N. R.

    2002-09-01

    Interconnecting distributed energy resources (DER) to the electric utility grid (or Area Electric Power System, Area EPS) involves system engineering, safety, and reliability considerations. This report documents US DOE Distribution and Interconnection R&D (formerly Distributed Power Program) activities, furthering the development and safe and reliable integration of DER interconnected with our nation's electric power systems. The key to that is system integration and technology development of the interconnection devices that perform the functions necessary to maintain the safety, power quality, and reliability of the EPS when DER are connected to it.

  9. Connectivity of streams and wetlands to downstream waters: An integrated systems framework

    Science.gov (United States)

    Leibowitz, Scott G.; Wigington, Parker J.; Schoefield, Kate A.; Alexander, Laurie C.; Vanderhoof, Melanie; Golden, Heather E.

    2018-01-01

    Interest in connectivity has increased in the aquatic sciences, partly because of its relevance to the Clean Water Act. This paper has two objectives: (1) provide a framework to understand hydrological, chemical, and biological connectivity, focusing on how headwater streams and wetlands connect to and contribute to rivers; and (2) briefly review methods to quantify hydrological and chemical connectivity. Streams and wetlands affect river structure and function by altering material and biological fluxes to the river; this depends on two factors: (1) functions within streams and wetlands that affect material fluxes; and (2) connectivity (or isolation) from streams and wetlands to rivers that allows (or prevents) material transport between systems. Connectivity can be described in terms of frequency, magnitude, duration, timing, and rate of change. It results from physical characteristics of a system, e.g., climate, soils, geology, topography, and the spatial distribution of aquatic components. Biological connectivity is also affected by traits and behavior of the biota. Connectivity can be altered by human impacts, often in complex ways. Because of variability in these factors, connectivity is not constant but varies over time and space. Connectivity can be quantified with field‐based methods, modeling, and remote sensing. Further studies using these methods are needed to classify and quantify connectivity of aquatic ecosystems and to understand how impacts affect connectivity.

  10. Optical Fiber Connection Navigation System Using Visible Light Communication in Central Office with Economic Evaluation

    Science.gov (United States)

    Waki, Masaki; Uruno, Shigenori; Ohashi, Hiroyuki; Manabe, Tetsuya; Azuma, Yuji

    We propose an optical fiber connection navigation system that uses visible light communication for an integrated distribution module in a central office. The system realizes an accurate database, requires less skilled work to operate and eliminates human error. This system can achieve a working time reduction of up to 88.0% compared with the conventional work without human error for the connection/removal of optical fiber cords, and is economical as regards installation and operation.

  11. Sharing Real-Time Objects in Distributed Embedded Systems

    DEFF Research Database (Denmark)

    Larsen, Erland Ketil; Havn, Ib

    2015-01-01

    microcontrollers connected by a RS-485 bus. The demo system shows that it is relatively simple to implement a distributed embedded system with the provided API, and the latency of the communication service is predictable. A low coupling to hardware makes it easy to port to another platform and/or another network...

  12. Characteristic Analysis of DC Electric Railway Systems with Superconducting Power Cables Connecting Power Substations

    Science.gov (United States)

    Ohsaki, H.; Matsushita, N.; Koseki, T.; Tomita, M.

    2014-05-01

    The application of superconducting power cables to DC electric railway systems has been studied. It could leads to an effective use of regenerative brake, improved energy efficiency, effective load sharing among the substations, etc. In this study, an electric circuit model of a DC feeding system is built and numerical simulation is carried out using MATLAB-Simulink software. A modified electric circuit model with an AC power grid connection taken into account is also created to simulate the influence of the grid connection. The analyses have proved that a certain amount of energy can be conserved by introducing superconducting cables, and that electric load distribution and concentration among the substations depend on the substation output voltage distribution.

  13. Characteristic analysis of DC electric railway systems with superconducting power cables connecting power substations

    International Nuclear Information System (INIS)

    Ohsaki, H; Matsushita, N; Koseki, T; Tomita, M

    2014-01-01

    The application of superconducting power cables to DC electric railway systems has been studied. It could leads to an effective use of regenerative brake, improved energy efficiency, effective load sharing among the substations, etc. In this study, an electric circuit model of a DC feeding system is built and numerical simulation is carried out using MATLAB-Simulink software. A modified electric circuit model with an AC power grid connection taken into account is also created to simulate the influence of the grid connection. The analyses have proved that a certain amount of energy can be conserved by introducing superconducting cables, and that electric load distribution and concentration among the substations depend on the substation output voltage distribution.

  14. The Integration of Renewable Energy Sources into Electric Power Distribution Systems, Vol. II Utility Case Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Zaininger, H.W.

    1994-01-01

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: the local solar insolation and/or wind characteristics, renewable energy source penetration level, whether battery or other energy storage systems are applied, and local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kW-scale applications may be connected to three+phase secondaries, and larger hundred-kW and y-scale applications, such as MW-scale windfarms, or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. In any case, the installation of small, distributed renewable energy sources is expected to have a significant impact on local utility distribution primary and secondary system economics. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications. The

  15. Improvement of voltage stability in wind farm connection to distribution network using FACTS devices

    Energy Technology Data Exchange (ETDEWEB)

    Salehi, V.; Kahrobaee, S.; Afsharnia, S. [School of Electrical and Computer Engineering, ECE, University of Tehran (Iran)

    2006-07-01

    Increasing capacity of connected wind power generation to utilities brings new opportunities and also problems to the utilities and customers. Evolution and analyzing of the connection conditions and effects of wind farms especially on remote areas are the main aspects of developing wind power on the utilities. The problem is that these wind turbine that mostly uses induction generators, tend to drain large amounts of VARs from the grid, potentially causing low voltage and maybe voltage stability problems for the utility owner, especially in the case of large load variation on distribution feeder. To investigate the impact of large wind farms on power system voltage stability, one of the Iran's wind farms is modeled in DIgSILENT software and the simulation results shows the effect of using FACTS devices including SVC and STATCOM on power system performance. (orig.)

  16. Channel-Island Connectivity Affects Water Exposure Time Distributions in a Coastal River Delta

    Science.gov (United States)

    Hiatt, Matthew; Castañeda-Moya, Edward; Twilley, Robert; Hodges, Ben R.; Passalacqua, Paola

    2018-03-01

    The exposure time is a water transport time scale defined as the cumulative amount of time a water parcel spends in the domain of interest regardless of the number of excursions from the domain. Transport time scales are often used to characterize the nutrient removal potential of aquatic systems, but exposure time distribution estimates are scarce for deltaic systems. Here we analyze the controls on exposure time distributions using a hydrodynamic model in two domains: the Wax Lake delta in Louisiana, USA, and an idealized channel-island complex. In particular, we study the effects of river discharge, vegetation, network geometry, and tides and use a simple model for the fractional removal of nitrate. In both domains, we find that channel-island hydrological connectivity significantly affects exposure time distributions and nitrate removal. The relative contributions of the island and channel portions of the delta to the overall exposure time distribution are controlled by island vegetation roughness and network geometry. Tides have a limited effect on the system's exposure time distribution but can introduce significant spatial variability in local exposure times. The median exposure time for the WLD model is 10 h under the conditions tested and water transport within the islands contributes to 37-50% of the network-scale exposure time distribution and 52-73% of the modeled nitrate removal, indicating that islands may account for the majority of nitrate removal in river deltas.

  17. Design of Distributed Engine Control Systems with Uncertain Delay.

    Directory of Open Access Journals (Sweden)

    Xiaofeng Liu

    Full Text Available Future gas turbine engine control systems will be based on distributed architecture, in which, the sensors and actuators will be connected to the controllers via a communication network. The performance of the distributed engine control (DEC is dependent on the network performance. This study introduces a distributed control system architecture based on a networked cascade control system (NCCS. Typical turboshaft engine-distributed controllers are designed based on the NCCS framework with a H∞ output feedback under network-induced time delays and uncertain disturbances. The sufficient conditions for robust stability are derived via the Lyapunov stability theory and linear matrix inequality approach. Both numerical and hardware-in-loop simulations illustrate the effectiveness of the presented method.

  18. Design of Distributed Engine Control Systems with Uncertain Delay.

    Science.gov (United States)

    Liu, Xiaofeng; Li, Yanxi; Sun, Xu

    Future gas turbine engine control systems will be based on distributed architecture, in which, the sensors and actuators will be connected to the controllers via a communication network. The performance of the distributed engine control (DEC) is dependent on the network performance. This study introduces a distributed control system architecture based on a networked cascade control system (NCCS). Typical turboshaft engine-distributed controllers are designed based on the NCCS framework with a H∞ output feedback under network-induced time delays and uncertain disturbances. The sufficient conditions for robust stability are derived via the Lyapunov stability theory and linear matrix inequality approach. Both numerical and hardware-in-loop simulations illustrate the effectiveness of the presented method.

  19. A Performance Comparison of Tree and Ring Topologies in Distributed System

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Min [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    A distributed system is a collection of computers that are connected via a communication network. Distributed systems have become commonplace due to the wide availability of low-cost, high performance computers and network devices. However, the management infrastructure often does not scale well when distributed systems get very large. Some of the considerations in building a distributed system are the choice of the network topology and the method used to construct the distributed system so as to optimize the scalability and reliability of the system, lower the cost of linking nodes together and minimize the message delay in transmission, and simplify system resource management. We have developed a new distributed management system that is able to handle the dynamic increase of system size, detect and recover the unexpected failure of system services, and manage system resources. The topologies used in the system are the tree-structured network and the ring-structured network. This thesis presents the research background, system components, design, implementation, experiment results and the conclusions of our work. The thesis is organized as follows: the research background is presented in chapter 1. Chapter 2 describes the system components, including the different node types and different connection types used in the system. In chapter 3, we describe the message types and message formats in the system. We discuss the system design and implementation in chapter 4. In chapter 5, we present the test environment and results, Finally, we conclude with a summary and describe our future work in chapter 6.

  20. Combined operation of AC and DC distribution system with distributed generation units

    International Nuclear Information System (INIS)

    Noroozian, R.; Abedi, M.; Gharehpetian, G.

    2010-01-01

    This paper presents a DC distribution system which has been supplied by external AC systems as well as local DG units in order to demonstrate an overall solution to power quality issue. In this paper, the proposed operation method is demonstrated by simulation of power transfer between external AC systems, DG units, AC and DC loads. The power flow control in DC distribution system has been achieved by network converters and DG converters. Also, the mathematical model of the network, DG and load converters are obtained by using the average technique, which allows converter systems accurately simulated and control strategies for this converters is achieved. A suitable control strategy for network converters has been proposed that involves DC voltage droop regulator and novel instantaneous power regulation scheme. Also, a novel control technique has been proposed for DG converters. In this paper, a novel control system based on stationary and synchronously rotating reference frame has been proposed for load converters for supplying AC loads connected to the DC bus by balanced voltages. The several case studies have been studied based on proposed methods. The simulation results show that DC distribution systems including DG units can improve the power quality at the point of common coupling (PCC) in the power distribution system or industrial power system. (authors)

  1. Distribution system reliability evaluation using credibility theory

    African Journals Online (AJOL)

    Xufeng Xu, Joydeep Mitra

    have found that credibility theory, which broadens the scope of fuzzy set theory, is an effective tool for representing fuzzy events, and have developed a theoretical .... Based on the status of switches, the distribution system can be divided into multiple SPSS, which are connected with tie switches. For example, SPSS.

  2. Wide-area-distributed storage system for a multimedia database

    Science.gov (United States)

    Ueno, Masahiro; Kinoshita, Shigechika; Kuriki, Makato; Murata, Setsuko; Iwatsu, Shigetaro

    1998-12-01

    We have developed a wide-area-distribution storage system for multimedia databases, which minimizes the possibility of simultaneous failure of multiple disks in the event of a major disaster. It features a RAID system, whose member disks are spatially distributed over a wide area. Each node has a device, which includes the controller of the RAID and the controller of the member disks controlled by other nodes. The devices in the node are connected to a computer, using fiber optic cables and communicate using fiber-channel technology. Any computer at a node can utilize multiple devices connected by optical fibers as a single 'virtual disk.' The advantage of this system structure is that devices and fiber optic cables are shared by the computers. In this report, we first described our proposed system, and a prototype was used for testing. We then discussed its performance; i.e., how to read and write throughputs are affected by data-access delay, the RAID level, and queuing.

  3. Connected motorcycle system performance.

    Science.gov (United States)

    2016-01-15

    This project characterized the performance of Connected Vehicle Systems (CVS) on motorcycles based on two key components: global positioning and wireless communication systems. Considering that Global Positioning System (GPS) and 5.9 GHz Dedicated Sh...

  4. A distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Jaerventausta, P; Verho, P; Kaerenlampi, M; Pitkaenen, M [Tampere Univ. of Technology (Finland); Partanen, J [Lappeenranta Univ. of Technology (Finland)

    1998-08-01

    vendors of the other systems. In our research project this alternative is preferred and used in developing an independent distribution management system. This text describes the basic models and functions of the intelligent distribution management system, which has been developed in the research project. The basic platform was developed by the end of 1995. In 1996 and 1997 new applications (e.g automatic switchings) have been developed, the domain has been enlarged to comprise the low-voltage networks and subtransmission networks, and the computer system integration has been extended (e.g. full-duplex communication with the SCADA, open relational database connection with the AM/FM/GIS). The chapter gives a general description of the distribution management system as a whole

  5. Electricity market design requirements for DC distribution systems

    NARCIS (Netherlands)

    Piao, L.; de Weerdt, M.M.; de Vries, L.J.

    2017-01-01

    DC distribution systems (DCDS) connect local generators and loads directly. By avoiding unnecessary losses in AC-DC conversion, DCDS offers higher energy efficiency. Since different parties in a DCDS may have conflicting goals, matching between power supply and demand should be done with carefully

  6. An improved method for calculating force distributions in moment-stiff timber connections

    DEFF Research Database (Denmark)

    Ormarsson, Sigurdur; Blond, Mette

    2012-01-01

    An improved method for calculating force distributions in moment-stiff metal dowel-type timber connections is presented, a method based on use of three-dimensional finite element simulations of timber connections subjected to moment action. The study that was carried out aimed at determining how...... the slip modulus varies with the angle between the direction of the dowel forces and the fibres in question, as well as how the orthotropic stiffness behaviour of the wood material affects the direction and the size of the forces. It was assumed that the force distribution generated by the moment action...

  7. An Analytical Method for Determining the Load Distribution of Single-Column Multibolt Connection

    Directory of Open Access Journals (Sweden)

    Nirut Konkong

    2017-01-01

    Full Text Available The purpose of this research was to investigate the effect of geometric variables on the bolt load distributions of a cold-formed steel bolt connection. The study was conducted using an experimental test, finite element analysis, and an analytical method. The experimental study was performed using single-lap shear testing of a concentrically loaded bolt connection fabricated from G550 cold-formed steel. Finite element analysis with shell elements was used to model the cold-formed steel plate while solid elements were used to model the bolt fastener for the purpose of studying the structural behavior of the bolt connections. Material nonlinearities, contact problems, and a geometric nonlinearity procedure were used to predict the failure behavior of the bolt connections. The analytical method was generated using the spring model. The bolt-plate interaction stiffness was newly proposed which was verified by the experiment and finite element model. It was applied to examine the effect of geometric variables on the single-column multibolt connection. The effects were studied of varying bolt diameter, plate thickness, and the plate thickness ratio (t2/t1 on the bolt load distribution. The results of the parametric study showed that the t2/t1 ratio controlled the efficiency of the bolt load distribution more than the other parameters studied.

  8. Modeling and design of a multivariable control system for multi-paralleled grid-connected inverters with LCL filter

    DEFF Research Database (Denmark)

    Akhavan, Ali; Mohammadi, Hamid Reza; Guerrero, Josep M.

    2018-01-01

    The quality of injected current in multi-paralleled grid-connected inverters is a matter of concern. The current controlled grid-connected inverters with LCL filter are widely used in the distributed generation (DG) systems due to their fast dynamic response and better power features. However...... with resonances in the system, damping methods such as passive or active damping is necessary. Secondly and perhaps more importantly, paralleled grid-connected inverters in a microgrid are coupled due to grid impedance. Generally, the coupling effect is not taken into account when designing the control systems...

  9. Advances in the spatially distributed ages-w model: parallel computation, java connection framework (JCF) integration, and streamflow/nitrogen dynamics assessment

    Science.gov (United States)

    AgroEcoSystem-Watershed (AgES-W) is a modular, Java-based spatially distributed model which implements hydrologic and water quality (H/WQ) simulation components under the Java Connection Framework (JCF) and the Object Modeling System (OMS) environmental modeling framework. AgES-W is implicitly scala...

  10. Steps towards the universal direct current distribution system

    NARCIS (Netherlands)

    Mackay, L.J.

    2018-01-01

    The traditional ac power system is challenged by emerging distributed renewable energy sources and an increase in installed load capacity, e.g., electric vehicles. Most of these new resources use inherently dc as do more and more appliances. This poses the question, if they should still be connected

  11. Potential Distribution of Mountain Cloud Forest in Michoacán, Mexico: Prioritization for Conservation in the Context of Landscape Connectivity.

    Science.gov (United States)

    Correa Ayram, Camilo A; Mendoza, Manuel E; Etter, Andrés; Pérez Salicrup, Diego R

    2017-07-01

    Landscape connectivity is essential in biodiversity conservation because of its ability to reduce the effect of habitat fragmentation; furthermore is a key property in adapting to climate change. Potential distribution models and landscape connectivity studies have increased with regard to their utility to prioritizing areas for conservation. The objective of this study was to model the potential distribution of Mountain cloud forests in the Transversal Volcanic System, Michoacán and to analyze the role of these areas in maintaining landscape connectivity. Potential distribution was modeled for the Mountain cloud forests based on the maximum entropy approach using 95 occurrence points and 17 ecological variables at 30 m spatial resolution. Potential connectivity was then evaluated by using a probability of connectivity index based on graph theory. The percentage of variation (dPCk) was used to identify the individual contribution of each potential area of Mountain cloud forests in overall connectivity. The different ways in which the potential areas of Mountain cloud forests can contribute to connectivity were evaluated by using the three fractions derived from dPCk (dPCintrak, dPCfluxk, and dPCconnectork). We determined that 37,567 ha of the TVSMich are optimal for the presence of Mountain cloud forests. The contribution of said area in the maintenance of connectivity was low. The conservation of Mountain cloud forests is indispensable, however, in providing or receiving dispersal flows through TVSMich because of its role as a connector element between another habitat types. The knowledge of the potential capacity of Mountain cloud forests to promote structural and functional landscape connectivity is key in the prioritization of conservation areas.

  12. Distributed control system for the FMIT

    International Nuclear Information System (INIS)

    Johnson, J.A.; Machen, D.R.; Suyama, R.M.

    1979-01-01

    The control system for the Fusion Materials Irradiation Test (FMIT) Facility will provide the primary data acquisition, control, and interface components that integrate all of the individual FMIT systems into a functional facility. The control system consists of a distributed computer network, control consoles and instrumentation subsystems. The FMIT Facility will be started, operated and secured from a Central Control Room. All FMIT systems and experimental functions will be monitored from the Central Control Room. The data acquisition and control signals will be handled by a data communications network, which connects dual computers in the Central Control Room to the microcomputers in CAMAC crates near the various subsystems of the facility

  13. Biota: Providing often-overlooked connections among freshwater systems

    Science.gov (United States)

    Mushet, David M.; Christensen, Jay R.; Bennett, Michah; Alexander, Laurie C.

    2017-01-01

    When we think about connections in and among aquatic systems, we typically envision clear headwater streams flowing into downstream rivers, river floodwaters spilling out onto adjacent floodplains, or groundwater connecting wetlands to lakes and streams. However, there is another layer of connectivity moving materials among freshwater systems, one with connections that are not always tied to downgradient flows of surface waters and groundwater. These movements are those of organisms, key components of virtually every freshwater system on the planet. In their movements across the landscape, biota connect aquatic systems in often-overlooked ways.

  14. Inverter sizing of grid-connected photovoltaic systems in the light of local solar resource distribution characteristics and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Burger, Bruno [Fraunhofer-Institute for Solar Energy Systems ISE, Department of Electrical Energy Systems, Heidenhofstr. 2, 79110 Freiburg (Germany); Ruether, Ricardo [LABSOLAR-Laboratorio de Energia Solar, LabEEE-Laboratorio de Eficiencia Energetica em Edificacoes, Universidade Federal de Santa Catarina/UFSC, Caixa Postal 476, Florianopolis-SC 88040-900 (Brazil)

    2006-01-15

    Inverter sizing strategies for grid-connected photovoltaic (PV) systems often do not take into account site-dependent peculiarities of ambient temperature, inverter operating temperature and solar irradiation distribution characteristics. The operating temperature affects PV modules and inverters in different ways and PV systems will hardly ever have a DC output equal to or above their STC-rated nominal power. Inverters are usually sized with a nominal AC output power some 30% (sometimes even more) below the PV array nominal power. In this paper, we show that this practice might lead to considerable energy losses, especially in the case of PV technologies with high temperature coefficients of power operating at sites with cold climates and of PV technologies with low temperature coefficients of power operating at sites with warm climates and an energy distribution of sunlight shifted to higher irradiation levels. In energy markets where PV kWh are paid premium tariffs, like in Germany, energy yield optimization might result in a favorable payback of the extra capital invested in a larger inverter. This paper discusses how the time resolution of solar radiation data influences the correct sizing of PV plants. We demonstrate that using instant (10s) irradiation values instead of average hourly irradiation values leads to considerable differences in optimum inverter sizing. When calculating inverter yearly efficiency values using both, hourly averages and 1-min averages, we can show that with increased time resolution of solar irradiation data there are higher calculated losses due to inverter undersizing. This reveals that hourly averages hide important irradiation peaks that need to be considered. We performed these calculations for data sets from pyranometer readings from Freiburg (48{sup o}N, Germany) and Florianopolis (27{sup o}S, Brazil) to further show the peculiarities of the site-dependent distribution of irradiation levels and its effects on inverter sizing

  15. Distributed computer control system for reactor optimization

    International Nuclear Information System (INIS)

    Williams, A.H.

    1983-01-01

    At the Oldbury power station a prototype distributed computer control system has been installed. This system is designed to support research and development into improved reactor temperature control methods. This work will lead to the development and demonstration of new optimal control systems for improvement of plant efficiency and increase of generated output. The system can collect plant data from special test instrumentation connected to dedicated scanners and from the station's existing data processing system. The system can also, via distributed microprocessor-based interface units, make adjustments to the desired reactor channel gas exit temperatures. The existing control equipment will then adjust the height of control rods to maintain operation at these temperatures. The design of the distributed system is based on extensive experience with distributed systems for direct digital control, operator display and plant monitoring. The paper describes various aspects of this system, with particular emphasis on: (1) the hierarchal system structure; (2) the modular construction of the system to facilitate installation, commissioning and testing, and to reduce maintenance to module replacement; (3) the integration of the system into the station's existing data processing system; (4) distributed microprocessor-based interfaces to the reactor controls, with extensive security facilities implemented by hardware and software; (5) data transfer using point-to-point and bussed data links; (6) man-machine communication based on VDUs with computer input push-buttons and touch-sensitive screens; and (7) the use of a software system supporting a high-level engineer-orientated programming language, at all levels in the system, together with comprehensive data link management

  16. Energy storage connection system

    Science.gov (United States)

    Benedict, Eric L.; Borland, Nicholas P.; Dale, Magdelena; Freeman, Belvin; Kite, Kim A.; Petter, Jeffrey K.; Taylor, Brendan F.

    2012-07-03

    A power system for connecting a variable voltage power source, such as a power controller, with a plurality of energy storage devices, at least two of which have a different initial voltage than the output voltage of the variable voltage power source. The power system includes a controller that increases the output voltage of the variable voltage power source. When such output voltage is substantially equal to the initial voltage of a first one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the first one of the energy storage devices. The controller then causes the output voltage of the variable voltage power source to continue increasing. When the output voltage is substantially equal to the initial voltage of a second one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the second one of the energy storage devices.

  17. Metric for Calculation of System Complexity based on its Connections

    Directory of Open Access Journals (Sweden)

    João Ricardo Braga de Paiva

    2017-02-01

    Full Text Available This paper proposes a methodology based on system connections to calculate its complexity. Two study cases are proposed: the dining Chinese philosophers’ problem and the distribution center. Both studies are modeled using the theory of Discrete Event Systems and simulations in different contexts were performed in order to measure their complexities. The obtained results present i the static complexity as a limiting factor for the dynamic complexity, ii the lowest cost in terms of complexity for each unit of measure of the system performance and iii the output sensitivity to the input parameters. The associated complexity and performance measures aggregate knowledge about the system.

  18. Short circuit analysis of distribution system with integration of DG

    DEFF Research Database (Denmark)

    Su, Chi; Liu, Zhou; Chen, Zhe

    2014-01-01

    and as a result bring challenges to the network protection system. This problem has been frequently discussed in the literature, but mostly considering only the balanced fault situation. This paper presents an investigation on the influence of full converter based wind turbine (WT) integration on fault currents......Integration of distributed generation (DG) such as wind turbines into distribution system is increasing all around the world, because of the flexible and environmentally friendly characteristics. However, DG integration may change the pattern of the fault currents in the distribution system...... during both balanced and unbalanced faults. Major factors such as external grid short circuit power capacity, WT integration location, connection type of WT integration transformer are taken into account. In turn, the challenges brought to the protection system in the distribution network are presented...

  19. Development of Nuclide Recognizing Prompt Radiation Distribution Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Uk Jae; Yoo, Dong Han; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-05-15

    The geographic data such as latitude, longitude and map image can be obtained by using GPS and digital map. Radiation data can be acquired by detector. Finally simultaneous visibility system can be operated by using CDMA. Existing radiation distribution monitoring system is based on random generated data. However the radiation distribution monitoring system is developed. It is based on real detected data. Connection between the detector and laptop which are located at a site place is operated by using Bluetooth. CDMA is used to simulate visibility system between laptop in a site place and server PC in the control office. Real map image is taken from digital map. Finally radiation distribution contour map on the real map image can be shown by using MATLAB. 5 figures appear which shows natural, {sup 137}Cs, {sup 131}I, artificial and total radiation dose rate. So this system can be used in everywhere to check the distribution of radiation with geographic information.

  20. Distributed radiation data acquisition system for KAPP

    International Nuclear Information System (INIS)

    Narsaiah, A.; Anantakrishnan, T.S.; Bairi, B.R.

    1992-01-01

    Increased concern for the safety of personnel working in Nuclear Power Stations demands an efficient centralized Radiation Data Acquisition System (RADAS) to monitor different types of radiation at distributed locations of the plant. The system provides a comprehensive picture of radio-activity level distribution in the reactor building to facilitate prompt and correct decision making to take care of any emergency situation. The system is build around an industrial IBM-PC connected to remote intelligent data acquisition units using serial data communication links. To ensure high system availability and ease of maintenance the mechanical moving disk storage has been replaced by solid state memory storage (RAM Disk). Functional CRT displays have been substituted by the assembly of IBM-PC Mother Board with built-in firmware and standard TV Monitor. The computer handles a variety of processing functions which include the conversion to engineering units, checking of alarms, display/printing of plant radiation level status and system diagnostics. Intelligent terminals have been provided with graphic and text formatting capabilities. A hot standby computer connected to analog and digital inputs takes over the system functions on the failure of the host system. Modular software written in the higher level C-language runs under a standard real-time operating system Kernel. This provides for easy modification and expandability at site. Based on the experience of its commissioning at Kakrapar Power Station a new compact version is being designed for a specific application in another class of reactor. (author). 3 refs., 1 fig

  1. Distributed consensus for metamorphic systems using a gossip algorithm for CAT(0) metric spaces

    Science.gov (United States)

    Bellachehab, Anass; Jakubowicz, Jérémie

    2015-01-01

    We present an application of distributed consensus algorithms to metamorphic systems. A metamorphic system is a set of identical units that can self-assemble to form a rigid structure. For instance, one can think of a robotic arm composed of multiple links connected by joints. The system can change its shape in order to adapt to different environments via reconfiguration of its constituting units. We assume in this work that several metamorphic systems form a network: two systems are connected whenever they are able to communicate with each other. The aim of this paper is to propose a distributed algorithm that synchronizes all the systems in the network. Synchronizing means that all the systems should end up having the same configuration. This aim is achieved in two steps: (i) we cast the problem as a consensus problem on a metric space and (ii) we use a recent distributed consensus algorithm that only make use of metrical notions.

  2. CODA: A scalable, distributed data acquisition system

    International Nuclear Information System (INIS)

    Watson, W.A. III; Chen, J.; Heyes, G.; Jastrzembski, E.; Quarrie, D.

    1994-01-01

    A new data acquisition system has been designed for physics experiments scheduled to run at CEBAF starting in the summer of 1994. This system runs on Unix workstations connected via ethernet, FDDI, or other network hardware to multiple intelligent front end crates -- VME, CAMAC or FASTBUS. CAMAC crates may either contain intelligent processors, or may be interfaced to VME. The system is modular and scalable, from a single front end crate and one workstation linked by ethernet, to as may as 32 clusters of front end crates ultimately connected via a high speed network to a set of analysis workstations. The system includes an extensible, device independent slow controls package with drivers for CAMAC, VME, and high voltage crates, as well as a link to CEBAF accelerator controls. All distributed processes are managed by standard remote procedure calls propagating change-of-state requests, or reading and writing program variables. Custom components may be easily integrated. The system is portable to any front end processor running the VxWorks real-time kernel, and to most workstations supplying a few standard facilities such as rsh and X-windows, and Motif and socket libraries. Sample implementations exist for 2 Unix workstation families connected via ethernet or FDDI to VME (with interfaces to FASTBUS or CAMAC), and via ethernet to FASTBUS or CAMAC

  3. Systems configured to distribute a telephone call, communication systems, communication methods and methods of routing a telephone call to a service representative

    Science.gov (United States)

    Harris, Scott H.; Johnson, Joel A.; Neiswanger, Jeffery R.; Twitchell, Kevin E.

    2004-03-09

    The present invention includes systems configured to distribute a telephone call, communication systems, communication methods and methods of routing a telephone call to a customer service representative. In one embodiment of the invention, a system configured to distribute a telephone call within a network includes a distributor adapted to connect with a telephone system, the distributor being configured to connect a telephone call using the telephone system and output the telephone call and associated data of the telephone call; and a plurality of customer service representative terminals connected with the distributor and a selected customer service representative terminal being configured to receive the telephone call and the associated data, the distributor and the selected customer service representative terminal being configured to synchronize, application of the telephone call and associated data from the distributor to the selected customer service representative terminal.

  4. A MODEL OF HETEROGENEOUS DISTRIBUTED SYSTEM FOR FOREIGN EXCHANGE PORTFOLIO ANALYSIS

    Directory of Open Access Journals (Sweden)

    Dragutin Kermek

    2006-06-01

    Full Text Available The paper investigates the design of heterogeneous distributed system for foreign exchange portfolio analysis. The proposed model includes few separated and dislocated but connected parts through distributed mechanisms. Making system distributed brings new perspectives to performance busting where software based load balancer gets very important role. Desired system should spread over multiple, heterogeneous platforms in order to fulfil open platform goal. Building such a model incorporates different patterns from GOF design patterns, business patterns, J2EE patterns, integration patterns, enterprise patterns, distributed design patterns to Web services patterns. The authors try to find as much as possible appropriate patterns for planned tasks in order to capture best modelling and programming practices.

  5. Reliability evaluation of linear multi-state consecutively-connected systems constrained by m consecutive and n total gaps

    International Nuclear Information System (INIS)

    Yu, Huan; Yang, Jun; Peng, Rui; Zhao, Yu

    2016-01-01

    This paper extends the linear multi-state consecutively-connected system (LMCCS) to the case of LMCCS-MN, where MN denotes the dual constraints of m consecutive gaps and n total gaps. All the nodes are distributed along a line and form a sequence. The distances between the adjacent nodes are usually non-uniform. The nodes except the last one can contain statistically independent multi-state connection elements (MCEs). Each MCE can provide a connection between the node at which it is located and the next nodes along the sequence. The LMCCS-MN fails if it meets either of the two constraints. The universal generating function technique is adopted to evaluate the system reliability. The optimal allocations of LMCCS-MN with two different types of failures are solved by genetic algorithm. Finally, two examples are given for the demonstration of the proposed model. - Highlights: • A new model of multi-state consecutively-connected system (LMCCS-MN) is proposed. • The non-uniform distributed nodes are involved in the proposed LMCCS-MN model. • An algorithm for system reliability evaluation is provided by the UGF method. • The computational complexity of the proposed algorithm is discussed in detail. • Optimal element allocation problem is formulated and solved.

  6. Smoothing of Grid-connected Wind-Diesel Power Output Using Energy Capacitor System

    Directory of Open Access Journals (Sweden)

    Adel A. Elbaset

    2014-06-01

    Full Text Available This paper presents a small hybrid power system consists of two types of power generation; wind turbine and diesel generation, DG connected to power distribution system. The fluctuations like random nature of wind power, turbulent wind, and sudden changes in load demand create imbalances in power distribution that can affect the frequency and the voltage in the power system. So, addition of Energy capacitor System, ECS is useful for compensation of fluctuating power, since it is capable of controlling both active and reactive power simultaneously and can smooth the output power flow. Hence, this paper proposes herein a dynamic model and simulation of a grid connected wind/DG based-ECS with power flow controllers between load and generation. Moreover, the paper presents a study to analyze the leveling of output fluctuation of wind power with the installation of ECS. To control the power exchanged between the ECS system and the AC grid, a load Following Control, LFC based supervisor is proposed with the aim to minimize variations of the power generated by the diesel generator. The interesting performance of the proposed supervisor is shown with the help of simulations. The computer simulation program is confirmed on a realistic circuit model which implemented in the Simulink environment of Matlab and works as if on line.

  7. 46 CFR 183.376 - Grounded distribution systems (neutral grounded).

    Science.gov (United States)

    2010-10-01

    ....376 Section 183.376 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER... propulsion, power, lighting, or distribution system having a neutral bus or conductor must have the neutral... generator to ground before the generator is connected to the bus, except the neutral of an emergency power...

  8. Grid Voltage Synchronization for Distributed Generation Systems under Grid Fault Conditions

    DEFF Research Database (Denmark)

    Luna, Alvaro; Rocabert, J.; Candela, I.

    2015-01-01

    on the installation of STATCOMs and DVRs, as well as on advanced control functionalities for the existing power converters of distributed generation plants, have contributed to enhance their response under faulty and distorted scenarios and, hence, to fulfill these requirements. In order to achieve satisfactory......The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and PV systems, are becoming very demanding. The Transmission System Operators (TSOs) are especially concerned about the Low Voltage Ride Through requirements. Solutions based...

  9. Connecting protein and mRNA burst distributions for stochastic models of gene expression

    International Nuclear Information System (INIS)

    Elgart, Vlad; Jia, Tao; Fenley, Andrew T; Kulkarni, Rahul

    2011-01-01

    The intrinsic stochasticity of gene expression can lead to large variability in protein levels for genetically identical cells. Such variability in protein levels can arise from infrequent synthesis of mRNAs which in turn give rise to bursts of protein expression. Protein expression occurring in bursts has indeed been observed experimentally and recent studies have also found evidence for transcriptional bursting, i.e. production of mRNAs in bursts. Given that there are distinct experimental techniques for quantifying the noise at different stages of gene expression, it is of interest to derive analytical results connecting experimental observations at different levels. In this work, we consider stochastic models of gene expression for which mRNA and protein production occurs in independent bursts. For such models, we derive analytical expressions connecting protein and mRNA burst distributions which show how the functional form of the mRNA burst distribution can be inferred from the protein burst distribution. Additionally, if gene expression is repressed such that observed protein bursts arise only from single mRNAs, we show how observations of protein burst distributions (repressed and unrepressed) can be used to completely determine the mRNA burst distribution. Assuming independent contributions from individual bursts, we derive analytical expressions connecting means and variances for burst and steady-state protein distributions. Finally, we validate our general analytical results by considering a specific reaction scheme involving regulation of protein bursts by small RNAs. For a range of parameters, we derive analytical expressions for regulated protein distributions that are validated using stochastic simulations. The analytical results obtained in this work can thus serve as useful inputs for a broad range of studies focusing on stochasticity in gene expression

  10. Low-voltage grid-connection of photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Collinson, A.; Thornycroft, J.

    1999-07-01

    This report summarises the results of a project aimed at developing technical guidelines concerning grid connected photovoltaic (PV) inverter generators which are to be published in draft form as the {sup U}K Technical Guidelines for Inverter Connected Single Phase Photovoltaic (PV) Generators up to 5kVA{sup .} The background to the use of PV in the UK is traced, and the technical criteria for electrical integration of PV systems, and UK guidelines for grid connected PV systems are examined. The findings of the working group of the International Energy Agency (IEA) Implementing Agreement on Photovoltaic Power Systems are also presented in this report. Appendices discuss the UK technical guidelines, the IEA Task V activities,, utility aspects of grid-connected PV systems, and demonstration tests on grid-connected PV systems, and lists Task V reports.

  11. FRIB Cryogenic Distribution System and Status

    Energy Technology Data Exchange (ETDEWEB)

    Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Laverdure, Nathaniel A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Yang, Shuo [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Nellis, Timothy [Michigan State Univ., East Lansing, MI (United States); Jones, S. [Michigan State Univ., East Lansing, MI (United States); Casagrande, Fabio [Michigan State Univ., East Lansing, MI (United States)

    2015-12-01

    The MSU-FRIB cryogenic distribution system supports the 2 K primary, 4 K primary, and 35 - 55 K shield operation of more than 70 loads in the accelerator and the experimental areas. It is based on JLab and SNS experience with bayonet-type disconnects between the loads and the distribution system for phased commissioning and maintenance. The linac transfer line, which features three separate transfer line segments for additional independence during phased commissioning at 4 K and 2 K, connects the folded arrangement of 49 cryomodules and 4 superconducting dipole magnets and a fourth transfer line supports the separator area cryo loads. The pressure reliefs for the transfer line process lines, located in the refrigeration room outside the tunnel/accelerator area, are piped to be vented outdoors. The transfer line designs integrate supply and return flow paths into a combined vacuum space. The main linac distribution segments are produced in a small number of standard configurations; a prototype of one such configuration has been fabricated at Jefferson Lab and has been installed at MSU to support testing of a prototype FRIB cryomodule.

  12. Finding significantly connected voxels based on histograms of connection strengths

    DEFF Research Database (Denmark)

    Kasenburg, Niklas; Pedersen, Morten Vester; Darkner, Sune

    2016-01-01

    We explore a new approach for structural connectivity based segmentations of subcortical brain regions. Connectivity based segmentations are usually based on fibre connections from a seed region to predefined target regions. We present a method for finding significantly connected voxels based...... on the distribution of connection strengths. Paths from seed voxels to all voxels in a target region are obtained from a shortest-path tractography. For each seed voxel we approximate the distribution with a histogram of path scores. We hypothesise that the majority of estimated connections are false-positives...... and that their connection strength is distributed differently from true-positive connections. Therefore, an empirical null-distribution is defined for each target region as the average normalized histogram over all voxels in the seed region. Single histograms are then tested against the corresponding null...

  13. Distributed Synchronization Control of Multiagent Systems With Unknown Nonlinearities.

    Science.gov (United States)

    Su, Shize; Lin, Zongli; Garcia, Alfredo

    2016-01-01

    This paper revisits the distributed adaptive control problem for synchronization of multiagent systems where the dynamics of the agents are nonlinear, nonidentical, unknown, and subject to external disturbances. Two communication topologies, represented, respectively, by a fixed strongly-connected directed graph and by a switching connected undirected graph, are considered. Under both of these communication topologies, we use distributed neural networks to approximate the uncertain dynamics. Decentralized adaptive control protocols are then constructed to solve the cooperative tracker problem, the problem of synchronization of all follower agents to a leader agent. In particular, we show that, under the proposed decentralized control protocols, the synchronization errors are ultimately bounded, and their ultimate bounds can be reduced arbitrarily by choosing the control parameter appropriately. Simulation study verifies the effectiveness of our proposed protocols.

  14. Performance Monitoring of Residential Hot Water Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Anna; Lanzisera, Steven; Lutz, Jim; Fitting, Christian; Kloss, Margarita; Stiles, Christopher

    2014-08-11

    Current water distribution systems are designed such that users need to run the water for some time to achieve the desired temperature, wasting energy and water in the process. We developed a wireless sensor network for large-scale, long time-series monitoring of residential water end use. Our system consists of flow meters connected to wireless motes transmitting data to a central manager mote, which in turn posts data to our server via the internet. This project also demonstrates a reliable and flexible data collection system that could be configured for various other forms of end use metering in buildings. The purpose of this study was to determine water and energy use and waste in hot water distribution systems in California residences. We installed meters at every end use point and the water heater in 20 homes and collected 1s flow and temperature data over an 8 month period. For a typical shower and dishwasher events, approximately half the energy is wasted. This relatively low efficiency highlights the importance of further examining the energy and water waste in hot water distribution systems.

  15. Control of hybrid fuel cell/energy storage distributed generation system against voltage sag

    Energy Technology Data Exchange (ETDEWEB)

    Hajizadeh, Amin; Golkar, Masoud Aliakbar [Electrical Engineering Department, K.N. Toosi University of Technology, Seyedkhandan, Dr. Shariati Ave, P.O. Box 16315-1355, Tehran (Iran)

    2010-06-15

    Fuel cell (FC) and energy storage (ES) based hybrid distributed power generation systems appear to be very promising for satisfying high energy and high power requirements of power quality problems in distributed generation (DG) systems. In this study, design of control strategy for hybrid fuel cell/energy storage distributed power generation system during voltage sag has been presented. The proposed control strategy allows hybrid distributed generation system works properly when a voltage disturbance occurs in distribution system and hybrid system stays connected to the main grid. Hence, modeling, controller design, and simulation study of a hybrid distributed generation system are investigated. The physical model of the fuel cell stack, energy storage and the models of power conditioning units are described. Then the control design methodology for each component of the hybrid system is proposed. Simulation results are given to show the overall system performance including active power control and voltage sag ride-through capability of the hybrid distributed generation system. (author)

  16. Grid Monitoring and Advanced Control of Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian Vasile

    . As an example, the latest published grid codes stress the ability of distributed generators, especially wind turbines, to stay connected during short grid disturbances and in addition to provide active/reactive power control at the point of common coupling. Based on the above facts, the need for improving...... reported in some countries creating concerns about power system stability. This leads to a continuous evolution of grid interconnection requirements towards a better controllability of generated power and an enhanced contribution of distributed power generation systems to power system stability...... and adding more features to the control of distributed power generation systems (DPGS) arises. As a consequence, this thesis focuses on grid monitoring methods and possible approaches in control in order to obtain a more reliable and  exible power generation system during normal and faulty grid conditions...

  17. Optimal operation management of fuel cell/wind/photovoltaic power sources connected to distribution networks

    Science.gov (United States)

    Niknam, Taher; Kavousifard, Abdollah; Tabatabaei, Sajad; Aghaei, Jamshid

    2011-10-01

    In this paper a new multiobjective modified honey bee mating optimization (MHBMO) algorithm is presented to investigate the distribution feeder reconfiguration (DFR) problem considering renewable energy sources (RESs) (photovoltaics, fuel cell and wind energy) connected to the distribution network. The objective functions of the problem to be minimized are the electrical active power losses, the voltage deviations, the total electrical energy costs and the total emissions of RESs and substations. During the optimization process, the proposed algorithm finds a set of non-dominated (Pareto) optimal solutions which are stored in an external memory called repository. Since the objective functions investigated are not the same, a fuzzy clustering algorithm is utilized to handle the size of the repository in the specified limits. Moreover, a fuzzy-based decision maker is adopted to select the 'best' compromised solution among the non-dominated optimal solutions of multiobjective optimization problem. In order to see the feasibility and effectiveness of the proposed algorithm, two standard distribution test systems are used as case studies.

  18. Cardea: Dynamic Access Control in Distributed Systems

    Science.gov (United States)

    Lepro, Rebekah

    2004-01-01

    Modern authorization systems span domains of administration, rely on many different authentication sources, and manage complex attributes as part of the authorization process. This . paper presents Cardea, a distributed system that facilitates dynamic access control, as a valuable piece of an inter-operable authorization framework. First, the authorization model employed in Cardea and its functionality goals are examined. Next, critical features of the system architecture and its handling of the authorization process are then examined. Then the S A M L and XACML standards, as incorporated into the system, are analyzed. Finally, the future directions of this project are outlined and connection points with general components of an authorization system are highlighted.

  19. Are PES connection costs too high?

    International Nuclear Information System (INIS)

    Scott, N.

    1998-01-01

    Windfarm developers often have good reason to question the costs they are quoted by their local distribution company for connection to the system, and these costs can now be challenged under the 'Competition in Connection' initiative. Econnect Ltd specialise in electrical connections for renewable generation throughout the UK and Europe, and have worked on many projects where alternative connections have been designed at more competitive prices. This paper provides some examples which illustrate the importance of acquiring a thorough understanding of all power system issues and PES concerns if the most cost-effective connection is to be realised. (Author)

  20. Energy system analysis of fuel cells and distributed generation

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Lund, Henrik

    2007-01-01

    This chapter introduces Energy System Analysis methodologies and tools, which can be used for identifying the best application of different Fuel Cell (FC) technologies to different regional or national energy systems. The main point is that the benefits of using FC technologies indeed depend...... on the energy system in which they are used. Consequently, coherent energy systems analyses of specific and complete energy systems must be conducted in order to evaluate the benefits of FC technologies and in order to be able to compare alternative solutions. In relation to distributed generation, FC...... technologies are very often connected to the use of hydrogen, which has to be provided e.g. from electrolysers. Decentralised and distributed generation has the possibility of improving the overall energy efficiency and flexibility of energy systems. Therefore, energy system analysis tools and methodologies...

  1. Modeling and control of distributed energy systems during transition between grid connected and standalone modes

    Science.gov (United States)

    Arafat, Md Nayeem

    Distributed generation systems (DGs) have been penetrating into our energy networks with the advancement in the renewable energy sources and energy storage elements. These systems can operate in synchronism with the utility grid referred to as the grid connected (GC) mode of operation, or work independently, referred to as the standalone (SA) mode of operation. There is a need to ensure continuous power flow during transition between GC and SA modes, referred to as the transition mode, in operating DGs. In this dissertation, efficient and effective transition control algorithms are developed for DGs operating either independently or collectively with other units. Three techniques are proposed in this dissertation to manage the proper transition operations. In the first technique, a new control algorithm is proposed for an independent DG which can operate in SA and GC modes. The proposed transition control algorithm ensures low total harmonic distortion (THD) and less voltage fluctuation during mode transitions compared to the other techniques. In the second technique, a transition control is suggested for a collective of DGs operating in a microgrid system architecture to improve the reliability of the system, reduce the cost, and provide better performance. In this technique, one of the DGs in a microgrid system, referred to as a dispatch unit , takes the additional responsibility of mode transitioning to ensure smooth transition and supply/demand balance in the microgrid. In the third technique, an alternative transition technique is proposed through hybridizing the current and droop controllers. The proposed hybrid transition control technique has higher reliability compared to the dispatch unit concept. During the GC mode, the proposed hybrid controller uses current control. During the SA mode, the hybrid controller uses droop control. During the transition mode, both of the controllers participate in formulating the inverter output voltage but with different

  2. An improved AVC strategy applied in distributed wind power system

    Science.gov (United States)

    Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.

    2016-08-01

    Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.

  3. Agent Services for Situation Aware Control of Power Systems With Distributed Generation

    DEFF Research Database (Denmark)

    Saleem, Arshad; Heussen, Kai; Lind, Morten

    2009-01-01

    Electric Power system of Denmark exhibits some unique characteristics. An increasing part of the electricity is produced by distributed generators (DGs). Most of these DGs are connected to the network at the distribution level. At the same time the concept of vehicle to grid (V2G) is already...... in the process of realization. This situation has created an incentive in electric power industry to utilize modern information and communication technologies (ICT) for improving the distribution system automation. This paper describes our work on how significantly increased amount of distributed generation...... services. We present results from several experiments where agents offer and utilize services in order to achieve distributed and autonomous control for subgrid operation of a distribution system. Finally it is discussed how the service oriented architecture can be combined with knowledge based reasoning...

  4. Analysis of nonlocal neural fields for both general and gamma-distributed connectivities

    Science.gov (United States)

    Hutt, Axel; Atay, Fatihcan M.

    2005-04-01

    This work studies the stability of equilibria in spatially extended neuronal ensembles. We first derive the model equation from statistical properties of the neuron population. The obtained integro-differential equation includes synaptic and space-dependent transmission delay for both general and gamma-distributed synaptic connectivities. The latter connectivity type reveals infinite, finite, and vanishing self-connectivities. The work derives conditions for stationary and nonstationary instabilities for both kernel types. In addition, a nonlinear analysis for general kernels yields the order parameter equation of the Turing instability. To compare the results to findings for partial differential equations (PDEs), two typical PDE-types are derived from the examined model equation, namely the general reaction-diffusion equation and the Swift-Hohenberg equation. Hence, the discussed integro-differential equation generalizes these PDEs. In the case of the gamma-distributed kernels, the stability conditions are formulated in terms of the mean excitatory and inhibitory interaction ranges. As a novel finding, we obtain Turing instabilities in fields with local inhibition-lateral excitation, while wave instabilities occur in fields with local excitation and lateral inhibition. Numerical simulations support the analytical results.

  5. ANALYSIS OF GRID-CONNECTED PHOTOVOLTAIC SYSTEM INTEGRATON ON LOW-VOLTAGE DISTRIBUTION NETWORK

    Directory of Open Access Journals (Sweden)

    NEMES C.

    2016-03-01

    Full Text Available The introduction of new local sources on the distribution network will impact the quality of power in different ways. The low-voltage customers are strongly affected by the level of power quality, especially by harmonic distortions. In present paper, the impact on the power quality of a low-voltage utility network with an integrated PV system has been assessed at the point of common coupling of the PV system. In this order, the most representative power quality indices concerning the harmonic distortion have been monitored and compared with the limits set by the corresponding standards.

  6. First Experiences Using XACML for Access Control in Distributed Systems

    Science.gov (United States)

    Lorch, Marcus; Proctor, Seth; Lepro, Rebekah; Kafura, Dennis; Shah, Sumit

    2003-01-01

    Authorization systems today are increasingly complex. They span domains of administration, rely on many different authentication sources, and manage permissions that can be as complex as the system itself. Worse still, while there are many standards that define authentication mechanisms, the standards that address authorization are less well defined and tend to work only within homogeneous systems. This paper presents XACML, a standard access control language, as one component of a distributed and inter-operable authorization framework. Several emerging systems which incorporate XACML are discussed. These discussions illustrate how authorization can be deployed in distributed, decentralized systems. Finally, some new and future topics are presented to show where this work is heading and how it will help connect the general components of an authorization system.

  7. Impact of electric vehicles in the steady state operation of distribution systems

    OpenAIRE

    Erasmo Saraiva de Castro

    2015-01-01

    This work aims to quantify the impact in the steady state operation of a distribution system when electric vehicles are connected. It is worth noting that the connection of them may cause significant changes in the voltage profile, in the degree of voltage unbalance and in the electrical losses of the system. In order to make this analysis, a three-phase power flow program was developed in MATLAB language. This program is based on the Ladder Iterative Technique and it contains models of overh...

  8. Distribution System Reliability Analysis for Smart Grid Applications

    Science.gov (United States)

    Aljohani, Tawfiq Masad

    Reliability of power systems is a key aspect in modern power system planning, design, and operation. The ascendance of the smart grid concept has provided high hopes of developing an intelligent network that is capable of being a self-healing grid, offering the ability to overcome the interruption problems that face the utility and cost it tens of millions in repair and loss. To address its reliability concerns, the power utilities and interested parties have spent extensive amount of time and effort to analyze and study the reliability of the generation and transmission sectors of the power grid. Only recently has attention shifted to be focused on improving the reliability of the distribution network, the connection joint between the power providers and the consumers where most of the electricity problems occur. In this work, we will examine the effect of the smart grid applications in improving the reliability of the power distribution networks. The test system used in conducting this thesis is the IEEE 34 node test feeder, released in 2003 by the Distribution System Analysis Subcommittee of the IEEE Power Engineering Society. The objective is to analyze the feeder for the optimal placement of the automatic switching devices and quantify their proper installation based on the performance of the distribution system. The measures will be the changes in the reliability system indices including SAIDI, SAIFI, and EUE. The goal is to design and simulate the effect of the installation of the Distributed Generators (DGs) on the utility's distribution system and measure the potential improvement of its reliability. The software used in this work is DISREL, which is intelligent power distribution software that is developed by General Reliability Co.

  9. Connected digit speech recognition system for Malayalam language

    Indian Academy of Sciences (India)

    A connected digit speech recognition is important in many applications such as automated banking system, catalogue-dialing, automatic data entry, automated banking system, etc. This paper presents an optimum speaker-independent connected digit recognizer for Malayalam language. The system employs Perceptual ...

  10. Connecting Research to Teaching: Using Data to Motivate the Use of Empirical Sampling Distributions

    Science.gov (United States)

    Lee, Hollylynne S.; Starling, Tina T.; Gonzalez, Marggie D.

    2014-01-01

    Research shows that students often struggle with understanding empirical sampling distributions. Using hands-on and technology models and simulations of problems generated by real data help students begin to make connections between repeated sampling, sample size, distribution, variation, and center. A task to assist teachers in implementing…

  11. The Design of Distributed Micro Grid Energy Storage System

    Science.gov (United States)

    Liang, Ya-feng; Wang, Yan-ping

    2018-03-01

    Distributed micro-grid runs in island mode, the energy storage system is the core to maintain the micro-grid stable operation. For the problems that it is poor to adjust at work and easy to cause the volatility of micro-grid caused by the existing energy storage structure of fixed connection. In this paper, an array type energy storage structure is proposed, and the array type energy storage system structure and working principle are analyzed. Finally, the array type energy storage structure model is established based on MATLAB, the simulation results show that the array type energy storage system has great flexibility, which can maximize the utilization of energy storage system, guarantee the reliable operation of distributed micro-grid and achieve the function of peak clipping and valley filling.

  12. Photovoltaic systems connected to electric power like distributed generators: the recent situation at the PVPS-IEA and at the Brazilian scenario; Sistemas fotovoltaicos conectados a rede eletrica como geradores distribuidos: a situacao recente no PVPS-IEA e no cenario brasileiro

    Energy Technology Data Exchange (ETDEWEB)

    Quaglia, Renato Brito; Oliveira, Sergio Henrique Ferreira de [Universidade Federal do ABC (UFABC), Santo Andre, SP (Brazil). Centro de Engenharia, Modelagem e Ciencias Sociais Aplicadas. Programa de Pos-Graduacao em Energia], email: renato.quaglia@ufabc.edu.br

    2008-07-01

    In this paper it is considered the use of Distributed Generation (GD) as a further option to centralized generation of electricity and treats its photovoltaic systems connected to power network (SFCR's) technology as an option in this interesting 'new' model to plan the expansion of the brazilian electrical energy matrix, mainly in urban centres. For this reason, it was necessary to mention the main characteristics of this technology as distributed generators, and the profile of his generation when connected in homes and commercial buildings. Moreover, it presents the benefits that these systems can offer the electricity sector, society and the economy. In the study of Photovoltaic Power Systems Programme (PVPS), specifically the situation of this technology in Germany, realized that the creation of mechanisms of financial incentives provided to implement some of the main barriers associated with the integration of photovoltaic systems as distributed generators. In assessing the Brazilian context, there was the incipient photovoltaic market in the country, even taking some systems already installed, note that the vast majority are intended for studies of Research and Development. There is also the exploitation of photovoltaic systems connected to the network for use in homes, businesses or industries, probably because of the lack of incentive programs for SFCR's. Although there is a programme of incentives to Alternative Sources of Electricity - Proinfa, it does not consider the SFCR's in its guidelines for qualification, only the wind systems, small hydroelectric plants and systems powered by biomass. Point is, therefore, the need for the creation of an energy policy that encourages the Brazilian market photovoltaic, more precisely a policy of offering incentives conditions of maturity of this technology when connected to the network - technical standards, decrease costs, creation of hand of specialized work, installation of manufacturers

  13. Distribution system constraints and their impact on distributed generation: final report

    Energy Technology Data Exchange (ETDEWEB)

    Thornycroft, J.; Caisley, A.; Russell, T.; Willis, S.; Youssef, R.; Bawden, R.; Holden, G.; Williams, J.

    2004-05-01

    This report examines constraints due to the connection of distributed generators to the distribution network focusing on small generators with the aim of developing technical and economic models to examine the relationship between the initial investment and the ensuing cost of the constraints under different scenarios. Constraints are defined as limitations to operation of connected generators, and the types of constraints, and the allocation of reinforcement and constraint costs are considered. Details are given of the modeling of sections of urban, rural and semi-rural network at Faversham, and the current constraints on this network are described.

  14. Overvoltages related to distributed generation-power system interconnection transformer

    Energy Technology Data Exchange (ETDEWEB)

    Zamanillo, G.R.; Gomez, J.C.; Florena, E.F. [Rio Cuarto National University (IPSEP/UNRC), Cordoba (Argentina). Electric Power Systems Protection Institute], Email: jcgomez@ing.unrc.edu.ar

    2009-07-01

    The energy crisis that experiences the world drives to carry to an extreme, the use of all energy sources which are available. The sources need to be connected to the electric network in their next point, requiring of electric-electronic interfaces. The traditional electric power systems are changing their characteristics, in what concerns to structure, operation and on overvoltage generation. This change is not taking place in coordinated form among the involved sectors. The interconnection of a Distributed Generator (DG) directly with the power system is objectionable and risky. It is required of an interconnection transformer which performs several functions. Rigid specifications do not exist in this respect, for the variety of systems in use in the world, nevertheless there are utilities recommendations. Overvoltages caused by the DG, which arise due to the change of structure of the electric system, are explained. The transformer connection selection, presents positive and negative aspects that impact the utility and the user in a different or many times in an antagonistic way. The phenomenon of balanced and unbalanced ferroresonance overvoltage is studied. This phenomenon can takes place when using DG, either with synchronous or asynchronous generator, and for any type of connection of the transformer. The necessary conditions so that the phenomenon appears are presented. Eight interconnection transformer connection ways were studied. It is concluded that the solutions to reach by means of the employment of the DG, offer technical-economic advantages so much to the utility as to the user. It is also concluded in this work that the more advisable interconnection type is function of the system connection type. (author)

  15. Adaptive Harmonic Compensation in Residential Distribution Grid by Roof-Top PV Systems

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2018-01-01

    grid- connected roof-top PV inverters in residential distribution grid can be an opportunity to engage these systems in the power quality issues as custom power devices. By implementing a proper control for roof-top PV inverters, these systems may in addition to inject the fundamental current......, additionally act like a virtual harmonic resistance and dedicate their additional current capacity to compensate the harmonics of residential distribution grid. In this paper, each roof-top PV system is a grid harmonic supervisor, where it continually measures the PCC voltage harmonics by Sliding Discrete...

  16. Synaptic Dynamics and Neuronal Network Connectivity are reflected in the Distribution of Times in Up states

    Directory of Open Access Journals (Sweden)

    Khanh eDao Duc

    2015-07-01

    Full Text Available The dynamics of neuronal networks connected by synaptic dynamics can sustain long periods of depolarization that can last for hundreds of milliseconds such as Up states recorded during sleep or anesthesia. Yet the underlying mechanism driving these periods remain unclear. We show here within a mean-field model that the residence times of the neuronal membrane potential in cortical Up states does not follow a Poissonian law, but presents several peaks. Furthermore, the present modeling approach allows extracting some information about the neuronal network connectivity from the time distribution histogram. Based on a synaptic-depression model, we find that these peaks, that can be observed in histograms of patch-clamp recordings are not artifacts of electrophysiological measurements, but rather are an inherent property of the network dynamics. Analysis of the equations reveals a stable focus located close to the unstable limit cycle, delimiting a region that defines the Up state. The model further shows that the peaks observed in the Up state time distribution are due to winding around the focus before escaping from the basin of attraction. Finally, we use in vivo recordings of intracellular membrane potential and we recover from the peak distribution, some information about the network connectivity. We conclude that it is possible to recover the network connectivity from the distribution of times that the neuronal membrane voltage spends in Up states.

  17. System analysis and planning of a gas distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Salas, Edwin F.M.; Farias, Helio Monteiro [AUTOMIND, Rio de Janeiro, RJ (Brazil); Costa, Carla V.R. [Universidade Salvador (UNIFACS), BA (Brazil)

    2009-07-01

    The increase in demand by gas consumers require that projects or improvements in gas distribution networks be made carefully and safely to ensure a continuous, efficient and economical supply. Gas distribution companies must ensure that the networks and equipment involved are defined and designed at the appropriate time to attend to the demands of the market. To do that a gas distribution network analysis and planning tool should use distribution networks and transmission models for the current situation and the future changes to be implemented. These models are used to evaluate project options and help in making appropriate decisions in order to minimize the capital investment in new components or simple changes in operational procedures. Gas demands are increasing and it is important that gas distribute design new distribution systems to ensure this growth, considering financial constraints of the company, as well as local legislation and regulation. In this study some steps of developing a flexible system that attends to those needs will be described. The analysis of distribution requires geographically referenced data for the models as well as an accurate connectivity and the attributes of the equipment. GIS systems are often used as a deposit center that holds the majority of this information. GIS systems are constantly updated as distribution network equipment is modified. The distribution network modeling gathered from this system ensures that the model represents the current network condition. The benefits of this architecture drastically reduce the creation and maintenance cost of the network models, because network components data are conveniently made available to populate the distribution network. This architecture ensures that the models are continually reflecting the reality of the distribution network. (author)

  18. Advanced connection systems for architectural glazing

    CERN Document Server

    Afghani Khoraskani, Roham

    2015-01-01

    This book presents the findings of a detailed study to explore the behavior of architectural glazing systems during and after an earthquake and to develop design proposals that will mitigate or even eliminate the damage inflicted on these systems. The seismic behavior of common types of architectural glazing systems are investigated and causes of damage to each system, identified. Furthermore, depending on the geometrical and structural characteristics, the ultimate horizontal load capacity of glass curtain wall systems is defined based on the stability of the glass components. Detailed attention is devoted to the incorporation of advanced connection devices between the structure of the building and the building envelope system in order to minimize the damage to glazed components. An innovative new connection device is introduced that results in a delicate and functional system easily incorporated into different architectural glazing systems, including those demanding maximum transparency.

  19. Wireless distributed functional electrical stimulation system

    Directory of Open Access Journals (Sweden)

    Jovičić Nenad S

    2012-08-01

    Full Text Available Abstract Background The control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement. Methods The new system comprises a set of miniature battery-powered devices with stimulating and sensing functionality mounted on the body of the subject. The devices communicate wirelessly with one coordinator device, which is connected to a host computer. The control algorithm runs on the computer in open- or closed-loop form. A prototype of the system was designed using commercial, off-the-shelf components. The propagation characteristics of electromagnetic waves and the distributed nature of the system were considered during the development of a two-hop routing protocol, which was implemented in the prototype’s software. Results The outcomes of this research include a novel system architecture and routing protocol and a functional prototype based on commercial, off-the-shelf components. A proof-of-concept study was performed on a hemiplegic subject with paresis of the right arm. The subject was tasked with generating a fully functional palmar grasp (closing of the fingers. One node was used to provide this movement, while a second node controlled the activation of extensor muscles to eliminate undesired wrist flexion. The system was tested with the open- and closed-loop control algorithms. Conclusions The system fulfilled technical and application requirements. The novel communication protocol enabled reliable real-time use of the system in both closed- and open-loop forms. The testing on a patient showed that the multi-node system could operate effectively to generate functional movement.

  20. Wireless distributed functional electrical stimulation system.

    Science.gov (United States)

    Jovičić, Nenad S; Saranovac, Lazar V; Popović, Dejan B

    2012-08-09

    The control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement. The new system comprises a set of miniature battery-powered devices with stimulating and sensing functionality mounted on the body of the subject. The devices communicate wirelessly with one coordinator device, which is connected to a host computer. The control algorithm runs on the computer in open- or closed-loop form. A prototype of the system was designed using commercial, off-the-shelf components. The propagation characteristics of electromagnetic waves and the distributed nature of the system were considered during the development of a two-hop routing protocol, which was implemented in the prototype's software. The outcomes of this research include a novel system architecture and routing protocol and a functional prototype based on commercial, off-the-shelf components. A proof-of-concept study was performed on a hemiplegic subject with paresis of the right arm. The subject was tasked with generating a fully functional palmar grasp (closing of the fingers). One node was used to provide this movement, while a second node controlled the activation of extensor muscles to eliminate undesired wrist flexion. The system was tested with the open- and closed-loop control algorithms. The system fulfilled technical and application requirements. The novel communication protocol enabled reliable real-time use of the system in both closed- and open-loop forms. The testing on a patient showed that the multi-node system could operate effectively to generate functional movement.

  1. Distributed cooperative regulation for multiagent systems and its applications to power systems: a survey.

    Science.gov (United States)

    Hu, Jianqiang; Li, Yaping; Yong, Taiyou; Cao, Jinde; Yu, Jie; Mao, Wenbo

    2014-01-01

    Cooperative regulation of multiagent systems has become an active research area in the past decade. This paper reviews some recent progress in distributed coordination control for leader-following multiagent systems and its applications in power system and mainly focuses on the cooperative tracking control in terms of consensus tracking control and containment tracking control. Next, methods on how to rank the network nodes are summarized for undirected/directed network, based on which one can determine which follower should be connected to leaders such that partial followers can perceive leaders' information. Furthermore, we present a survey of the most relevant scientific studies investigating the regulation and optimization problems in power systems based on distributed strategies. Finally, some potential applications in the frequency tracking regulation of smart grids are discussed at the end of the paper.

  2. Study of Power Flow Algorithm of AC/DC Distribution System including VSC-MTDC

    Directory of Open Access Journals (Sweden)

    Haifeng Liang

    2015-08-01

    Full Text Available In recent years, distributed generation and a large number of sensitive AC and DC loads have been connected to distribution networks, which introduce a series of challenges to distribution network operators (DNOs. In addition, the advantages of DC distribution networks, such as the energy conservation and emission reduction, mean that the voltage source converter based multi-terminal direct current (VSC-MTDC for AC/DC distribution systems demonstrates a great potential, hence drawing growing research interest. In this paper, considering losses of the reactor, the filter and the converter, a mathematical model of VSC-HVDC for the load flow analysis is derived. An AC/DC distribution network architecture has been built, based on which the differences in modified equations of the VSC-MTDC-based network under different control modes are analyzed. In addition, corresponding interface functions under five control modes are provided, and a back/forward iterative algorithm which is applied to power flow calculation of the AC/DC distribution system including VSC-MTDC is proposed. Finally, by calculating the power flow of the modified IEEE14 AC/DC distribution network, the efficiency and validity of the model and algorithm are evaluated. With various distributed generations connected to the network at appropriate locations, power flow results show that network losses and utilization of transmission networks are effectively reduced.

  3. Grid-Connected Inverter for Distributed Generation in Microgrid

    DEFF Research Database (Denmark)

    Naderipour, Amirreza; Miveh, Mohammad Reza; Guerrero, Josep M.

    for power generation. DGS units can operate in parallel to the main grid or in a Microgrid (MG) mode. An MG is a discrete energy system consisting of DGSs and loads capable of operating in parallel with, or independently from, the main grid. Meanwhile, Grid-Connected Inverters (GCIs) are typically used...

  4. Overview of Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    A continuous booming installation of solar photovoltaic (PV) systems has been witnessed worldwide. It is mainly driven by the imperative demand of “clean” power generation from renewables. Grid-connected PV systems will thus become an even more active player in the future mixed power systems, which...... systems. This chapter thus gives an overview of the advancement of power electronics converters in single-phase grid-connected PV systems, being commonly used in residential applications. Demands to single-phase grid-connected PV systems and the general control strategies are also addressed...... are linked together by a vast of power electronics converters and the power grid. In order to achieve a reliable and efficient power generation from PV systems, more stringent demands have been imposed on the entire PV system. It, in return, advances the development of the power converter technology in PV...

  5. Economic performance and policies for grid-connected residential solar photovoltaic systems in Brazil

    International Nuclear Information System (INIS)

    Mitscher, Martin; Rüther, Ricardo

    2012-01-01

    We analyze the economic competitiveness of grid-connected, distributed solar photovoltaic generation through small-scale rooftop installations in five Brazilian state-capitals. The locations represent a comprehensive set of the two essential parameters for the economic viability of PV—solar irradiation and local electricity tariffs. Levelized electricity costs (LEC) for PV generation and net present values (NPV) for a specific PV system are presented. The analysis comprises three different interest rate scenarios reflecting different conditions for capital acquisition to finance the generators; subsidized, mature market and country-specific risk-adjusted interest. In the NPV analysis, revenue flow is modeled by the sale of PV electricity at current residential tariffs assuming net metering. Using subsidized interest rates, the analysis shows that solar PV electricity is already competitive in Brazil, while in the country-specific risk-adjusted rate, the declining, but still high capital costs of PV make it economically unfeasible. At a mature market interest rate, PV competitiveness is largely dependent on the residential tariff. Economic competitiveness in this scenario is given for locations with high residential tariffs. We demonstrate the high potential of distributed generation with photovoltaic installations in Brazil, and show that under certain conditions, grid-connected PV can be economically competitive in a developing country. - Highlights: ► Debt financed grid-connected PV on Brazilian rooftops can be economically feasible since 2011. ► The cost of capital in Brazil is the decisive parameter in PV competitiveness with conventional generation sources. ► Low-cost, long-term financing is an essential requirement for PV to become an economically justifiable generation alternative. ► The Brazilian market holds huge potential for distributed, residential rooftop PV systems of small size.

  6. A Multi-Functional Power Electronic Converter in Distributed Generation Power Systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Pedersen, John Kim

    2005-01-01

    of the converter interfacing a wind power generation unit is also given. The power electronic interface performs the optimal operation in the wind turbine system to extract the maximum wind power, while it also plays a key role in a hybrid compensation system that consists of the active power electronic converter......This paper presents a power electronic converter which is used as an interface for a distributed generation unit/energy storage device, and also functioned as an active power compensator in a hybrid compensation system. The operation and control of the converter have been described. An example...... and passive filters connected to each distorting load or distributed generation (DG) unit. The passive filters are distributely located to remove major harmonics and provide reactive power compensation. The active power electronic filter corrects the system unbalance, removes the remaining harmonic components...

  7. Localization, distribution, and connectivity of neuropeptide Y in the human and porcine retinas - a comparative study

    DEFF Research Database (Denmark)

    Christiansen, Anders Tolstrup; Kiilgaard, Jens Folke; Klemp, Kristian

    2018-01-01

    retinal signaling. These findings extend existing knowledge on NPY and NPY-expressing cells in the human and porcine retina showing a high degree of comparability. The extensive distribution and connectivity of NPY-ir cells described in the present study further highlights the potential importance of NPY......Neuropeptide Y (NPY) is a peptide neurotransmitter abundantly expressed in the mammalian retina. Since its discovery, NPY has been studied in retinas of several species, but detailed characterization of morphology, cell-type, and connectivity has never been conducted in larger mammals including...... humans and pigs. As the pig due to size and cellular composition is a well-suited animal for retinal research, we chose to compare the endogenous NPY system of the human retina to that of pigs to support future research in this field. In the present study, using immunohistochemistry, confocal microscopy...

  8. Fault-tolerant clock synchronization in distributed systems

    Science.gov (United States)

    Ramanathan, Parameswaran; Shin, Kang G.; Butler, Ricky W.

    1990-01-01

    Existing fault-tolerant clock synchronization algorithms are compared and contrasted. These include the following: software synchronization algorithms, such as convergence-averaging, convergence-nonaveraging, and consistency algorithms, as well as probabilistic synchronization; hardware synchronization algorithms; and hybrid synchronization. The worst-case clock skews guaranteed by representative algorithms are compared, along with other important aspects such as time, message, and cost overhead imposed by the algorithms. More recent developments such as hardware-assisted software synchronization and algorithms for synchronizing large, partially connected distributed systems are especially emphasized.

  9. Supervision and control of grid connected PV-Storage systems with the five level diode clamped inverter

    International Nuclear Information System (INIS)

    Himour, Kamal; Ghedamsi, Kaci; Berkouk, El Madjid

    2014-01-01

    Highlights: • Use of battery bank in grid connection photovoltaic system to ensure the energetic autonomy of the system. • Improve the quality of energy by the use of five-level inverter in a grid connection PV generation system. • Control of inverter by fast and simplified space vector pulse width modulation. • Control and supervision of active and reactive power in the grid. - Abstract: This paper aimed to evaluate the use of photovoltaic-battery storage systems to supply electric power in the distribution grid through a multilevel inverter. The proposed system is composed by four PV generators with MPPT (P and O) control, four battery storage systems connected to each capacitor of the DC link and a five level diode clamped inverter connected to the grid by a traditional three phase transformer. The proposed control has a hierarchical structure with both a grid side control level to regulate the power and the current injected to the grid and four input side regulation units. The system operator controls the power production of the four PV generators by sending out reference power signals to each input side regulation unit, the input side regulation units regulate the voltage of each capacitor of the DC link, regulate the voltage and the state of charge of each battery storage system

  10. Enhancing the Capacity of the AC Distribution System Using DC Interlinks - A Step Towards Future DC Grid

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Guerrero, Josep M.; Teodorescu, Remus

    2015-01-01

    The development of distributed generation system and electric vehicles is bound to strain the distribution network. A typical radial distribution feeder suffers from the voltage fluctuation and feeder overload in the presence of a large amount of variable renewable generation. This paper presents...... a concept of enhancing the power handling capacity of distribution networks using dc grid interconnections. Control of both the active and reactive power exchange between the ac feeder and the interconnecting power converter has been proposed for the voltage regulation at the ac feeder terminal. Besides......, the dc grid interconnection also allows the introduction of a common storage system which can be shared by the connected ac feeders, and the dc grid connection to other renewable energy resources. The increased power handling capacity and improved voltage profile of the ac distribution feeder using...

  11. Distributed Optimisation Algorithm for Demand Side Management in a Grid-Connected Smart Microgrid

    Directory of Open Access Journals (Sweden)

    Omowunmi Mary Longe

    2017-06-01

    Full Text Available The contributions of Distributed Energy Generation (DEG and Distributed Energy Storage (DES for Demand Side Management (DSM purposes in a smart macrogrid or microgrid cannot be over-emphasised. However, standalone DEG and DES can lead to under-utilisation of energy generation by consumers and financial investments; in grid-connection mode, though, DEG and DES can offer arbitrage opportunities for consumers and utility provider(s. A grid-connected smart microgrid comprising heterogeneous (active and passive smart consumers, electric vehicles and a large-scale centralised energy storage is considered in this paper. Efficient energy management by each smart entity is carried out by the proposed Microgrid Energy Management Distributed Optimisation Algorithm (MEM-DOA installed distributively within the network according to consumer type. Each smart consumer optimises its energy consumption and trading for comfort (demand satisfaction and profit. The proposed model was observed to yield better consumer satisfaction, higher financial savings, and reduced Peak-to-Average-Ratio (PAR demand on the utility grid. Other associated benefits of the model include reduced investment on peaker plants, grid reliability and environmental benefits. The MEM-DOA also offered participating smart consumers energy and tariff incentives so that passive smart consumers do not benefit more than active smart consumers, as was the case with some previous energy management algorithms.

  12. Low Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems connected...... to the low-voltage grid will be more active with functionalities of low voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in low voltage ride through operation in order...... to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability...

  13. Anode-cathode power distribution systems and methods of using the same for electrochemical reduction

    Science.gov (United States)

    Koehl, Eugene R; Barnes, Laurel A; Wiedmeyer, Stanley G; Williamson, Mark A; Willit, James L

    2014-01-28

    Power distribution systems are useable in electrolytic reduction systems and include several cathode and anode assembly electrical contacts that permit flexible modular assembly numbers and placement in standardized connection configurations. Electrical contacts may be arranged at any position where assembly contact is desired. Electrical power may be provided via power cables attached to seating assemblies of the electrical contacts. Cathode and anode assembly electrical contacts may provide electrical power at any desired levels. Pairs of anode and cathode assembly electrical contacts may provide equal and opposite electrical power; different cathode assembly electrical contacts may provide different levels of electrical power to a same or different modular cathode assembly. Electrical systems may be used with an electrolyte container into which the modular cathode and anode assemblies extend and are supported above, with the modular cathode and anode assemblies mechanically and electrically connecting to the respective contacts in power distribution systems.

  14. Distributed Cooperative Regulation for Multiagent Systems and Its Applications to Power Systems: A Survey

    Science.gov (United States)

    Li, Yaping; Yong, Taiyou; Yu, Jie; Mao, Wenbo

    2014-01-01

    Cooperative regulation of multiagent systems has become an active research area in the past decade. This paper reviews some recent progress in distributed coordination control for leader-following multiagent systems and its applications in power system and mainly focuses on the cooperative tracking control in terms of consensus tracking control and containment tracking control. Next, methods on how to rank the network nodes are summarized for undirected/directed network, based on which one can determine which follower should be connected to leaders such that partial followers can perceive leaders' information. Furthermore, we present a survey of the most relevant scientific studies investigating the regulation and optimization problems in power systems based on distributed strategies. Finally, some potential applications in the frequency tracking regulation of smart grids are discussed at the end of the paper. PMID:25243199

  15. DC Distributed Power Systems. Analysis, Design and Control for a Renewable Energy System

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Per

    2002-12-01

    Renewable energy systems are likely to become wide spread in the future due to environmental demands. As a consequence of the dispersed nature of renewable energy systems, this implies that there will be a distributed generation of electric power. Since most of the distributed electrical energy sources do not provide their electric power at line frequency and voltage, a DC bus is a useful common connection for several such sources. Due to the differences in output voltage among the sources, depending on both the type of source and their actual operating point, the sources are connected to the DC power system via power electronic converters. The intention behind the presented work is not to replace the existing AC power system, but to include local DC power systems. The AC and DC power systems are connected at some points in the network. The renewable energy sources are weak compared to the present hydro power and nuclear power plants, resulting in a need of power conditioning before the renewable energy is fed to the transmission lines. The benefit of such an approach is that power conditioning is applied on a central level, i.e. at the interface between the AC and DC power systems. The thesis starts with an overview of related work. Present DC transmission systems are discussed and investigated in simulations. Then, different methods for load sharing and voltage control are discussed. Especially, the voltage droop control scheme is examined thoroughly. Since the droop control method does not require any high-speed communication between sources and loads, this is considered the most suitable for DC distributed power systems. The voltage feed back design of the controller also results in a specification of the DC bus capacitors (equivalents to DC link capacitors of single converters) needed for filtering. If the converters in the DC distribution system are equipped with capacitors selected from this design criterion and if the DC bus impedance is neglected, the

  16. Complete distributed computing environment for a HEP experiment: experience with ARC-connected infrastructure for ATLAS

    International Nuclear Information System (INIS)

    Read, A; Taga, A; O-Saada, F; Pajchel, K; Samset, B H; Cameron, D

    2008-01-01

    Computing and storage resources connected by the Nordugrid ARC middleware in the Nordic countries, Switzerland and Slovenia are a part of the ATLAS computing Grid. This infrastructure is being commissioned with the ongoing ATLAS Monte Carlo simulation production in preparation for the commencement of data taking in 2008. The unique non-intrusive architecture of ARC, its straightforward interplay with the ATLAS Production System via the Dulcinea executor, and its performance during the commissioning exercise is described. ARC support for flexible and powerful end-user analysis within the GANGA distributed analysis framework is also shown. Whereas the storage solution for this Grid was earlier based on a large, distributed collection of GridFTP-servers, the ATLAS computing design includes a structured SRM-based system with a limited number of storage endpoints. The characteristics, integration and performance of the old and new storage solutions are presented. Although the hardware resources in this Grid are quite modest, it has provided more than double the agreed contribution to the ATLAS production with an efficiency above 95% during long periods of stable operation

  17. Complete distributed computing environment for a HEP experiment: experience with ARC-connected infrastructure for ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Read, A; Taga, A; O-Saada, F; Pajchel, K; Samset, B H; Cameron, D [Department of Physics, University of Oslo, P.b. 1048 Blindern, N-0316 Oslo (Norway)], E-mail: a.l.read@fys.uio.no

    2008-07-15

    Computing and storage resources connected by the Nordugrid ARC middleware in the Nordic countries, Switzerland and Slovenia are a part of the ATLAS computing Grid. This infrastructure is being commissioned with the ongoing ATLAS Monte Carlo simulation production in preparation for the commencement of data taking in 2008. The unique non-intrusive architecture of ARC, its straightforward interplay with the ATLAS Production System via the Dulcinea executor, and its performance during the commissioning exercise is described. ARC support for flexible and powerful end-user analysis within the GANGA distributed analysis framework is also shown. Whereas the storage solution for this Grid was earlier based on a large, distributed collection of GridFTP-servers, the ATLAS computing design includes a structured SRM-based system with a limited number of storage endpoints. The characteristics, integration and performance of the old and new storage solutions are presented. Although the hardware resources in this Grid are quite modest, it has provided more than double the agreed contribution to the ATLAS production with an efficiency above 95% during long periods of stable operation.

  18. Use of the BOINC system for distributed data collection in the “Internet of Things”

    Directory of Open Access Journals (Sweden)

    Handrik Marián

    2018-01-01

    Full Text Available The BOINC software package allows the creation of massive computational systems for distributed computing. The system is designed to use heterogeneous computing devices that are differing in hardware architecture and operating systems. The variability and versatility of the BOINC system allows its use to create a distributed system for measurement and data collection. This is done through the standard HTTP and HTTPS web communication protocol that is used on the Internet in connected devices, so called “Internet of things”.

  19. Climate effects on the distribution of wetland habitats and connectivity in networks of migratory waterbirds

    Science.gov (United States)

    Bellisario, Bruno; Cerfolli, Fulvio; Nascetti, Giuseppe

    2014-07-01

    The establishment and maintenance of conservation areas are among the most common measures to mitigate the loss of biodiversity. However, recent advances in conservation biology have challenged the reliability of such areas to cope with variation in climate conditions. Climate change can reshuffle the geographic distribution of species, but in many cases suitable habitats become scarce or unavailable, limiting the ability to migrate or adapt in response to modified environments. In this respect, the extent to which existing protected areas are able to compensate changes in habitat conditions to ensure the persistence of species still remains unclear. We used a spatially explicit model to measure the effects of climate change on the potential distribution of wetland habitats and connectivity of Natura 2000 sites in Italy. The effects of climate change were measured on the potential for water accumulation in a given site, as a surrogate measure for the persistence of aquatic ecosystems and their associated migratory waterbirds. Climate impacts followed a geographic trend, changing the distribution of suitable habitats for migrants and highlighting a latitudinal threshold beyond which the connectivity reaches a sudden collapse. Our findings show the relative poor reliability of most sites in dealing with changing habitat conditions and ensure the long-term connectivity, with possible consequences for the persistence of species. Although alterations of climate suitability and habitat destruction could impact critical areas for migratory waterbirds, more research is needed to evaluate all possible long-term effects on the connectivity of migratory networks.

  20. OpenID Connect as a security service in cloud-based medical imaging systems.

    Science.gov (United States)

    Ma, Weina; Sartipi, Kamran; Sharghigoorabi, Hassan; Koff, David; Bak, Peter

    2016-04-01

    The evolution of cloud computing is driving the next generation of medical imaging systems. However, privacy and security concerns have been consistently regarded as the major obstacles for adoption of cloud computing by healthcare domains. OpenID Connect, combining OpenID and OAuth together, is an emerging representational state transfer-based federated identity solution. It is one of the most adopted open standards to potentially become the de facto standard for securing cloud computing and mobile applications, which is also regarded as "Kerberos of cloud." We introduce OpenID Connect as an authentication and authorization service in cloud-based diagnostic imaging (DI) systems, and propose enhancements that allow for incorporating this technology within distributed enterprise environments. The objective of this study is to offer solutions for secure sharing of medical images among diagnostic imaging repository (DI-r) and heterogeneous picture archiving and communication systems (PACS) as well as Web-based and mobile clients in the cloud ecosystem. The main objective is to use OpenID Connect open-source single sign-on and authorization service and in a user-centric manner, while deploying DI-r and PACS to private or community clouds should provide equivalent security levels to traditional computing model.

  1. A distributed clinical decision support system architecture

    Directory of Open Access Journals (Sweden)

    Shaker H. El-Sappagh

    2014-01-01

    Full Text Available This paper proposes an open and distributed clinical decision support system architecture. This technical architecture takes advantage of Electronic Health Record (EHR, data mining techniques, clinical databases, domain expert knowledge bases, available technologies and standards to provide decision-making support for healthcare professionals. The architecture will work extremely well in distributed EHR environments in which each hospital has its own local EHR, and it satisfies the compatibility, interoperability and scalability objectives of an EHR. The system will also have a set of distributed knowledge bases. Each knowledge base will be specialized in a specific domain (i.e., heart disease, and the model achieves cooperation, integration and interoperability between these knowledge bases. Moreover, the model ensures that all knowledge bases are up-to-date by connecting data mining engines to each local knowledge base. These data mining engines continuously mine EHR databases to extract the most recent knowledge, to standardize it and to add it to the knowledge bases. This framework is expected to improve the quality of healthcare, reducing medical errors and guaranteeing the safety of patients by helping clinicians to make correct, accurate, knowledgeable and timely decisions.

  2. 30 CFR 77.806 - Connection of single-phase loads.

    Science.gov (United States)

    2010-07-01

    ... COAL MINES Surface High-Voltage Distribution § 77.806 Connection of single-phase loads. Single-phase loads, such as transformer primaries, shall be connected phase to phase in resistance grounded systems. ...

  3. Computer aided planning of distribution systems and connection with medium term load forecast

    Energy Technology Data Exchange (ETDEWEB)

    di Salvatore, F; Grattieri, W; Insinga, F; Malafarina, L; Mazzoni, M; Nicola, G

    1991-12-31

    In order to perform planning studies on HV (40-l50 kV), MV and LV networks, ENEL (Italian Electricity Board) has developed a computation system composed of a set of integrated programs which utilize the information stored in several data bases, with the aim of: providing energy consumption forecasts for each area of the country; transfering consumption for each area to the distribution network nodes and to evaluating the electric demand by using a statistical power/energy correlation model; analyzing several network development alternatives and selecting the optimum development plan by comparing the overall costs (investments, operation, risk). In order to make its utilization by planners easier, the computation system will be operated with interactive and graphic procedures made available by the use of graphic work stations. This report describes the main objectives and basic hypotheses assumed in the preparation of the computation system, as well as, the system`s general architecture.

  4. Probability of islanding in utility networks due to grid connected photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Verhoeven, B.

    2002-09-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme takes a look at the probability of islanding in utility networks due to grid-connected photovoltaic power systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This report summarises the results on a study on the probability of islanding in power networks with a high penetration level of grid connected PV-systems. The results are based on measurements performed during one year in a Dutch utility network. The measurements of active and reactive power were taken every second for two years and stored in a computer for off-line analysis. The area examined and its characteristics are described, as are the test set-up and the equipment used. The ratios between load and PV-power are discussed. The general conclusion is that the probability of islanding is virtually zero for low, medium and high penetration levels of PV-systems.

  5. Z-Source-Inverter-Based Flexible Distributed Generation System Solution for Grid Power Quality Improvement

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Vilathgamuwa, D. M.; Loh, Poh Chiang

    2009-01-01

    Distributed generation (DG) systems are usually connected to the grid using power electronic converters. Power delivered from such DG sources depends on factors like energy availability and load demand. The converters used in power conversion do not operate with their full capacity all the time......-stage buck-boost inverter, recently proposed Z-source inverter (ZSI) is a good candidate for future DG systems. This paper presents a controller design for a ZSI-based DG system to improve power quality of distribution systems. The proposed control method is tested with simulation results obtained using...

  6. Performance evaluation of a 2-mode PV grid connected system in Thailand -- Case study

    Energy Technology Data Exchange (ETDEWEB)

    Jivacate, C.; Mongconvorawan, S.; Sinratanapukdee, E.; Limsawatt, W. [Electricity Generating Authority of Thailand, Nontha Buri (Thailand)

    1994-12-31

    A PV grid connected system with small battery bank has been set up in a rural district, North Thailand in order to demonstrate a 2-mode operation concept. The objective is to gain experience on the PV grid connected concept without battery storage. However, due to the evening peak demand and a rather weak distribution grid which is typical in rural areas, small battery bank is still required to enable the maximum energy transfer to grid for the time being before moving fully to the no battery mode. The analyzed data seems to indicate possible performance improvement by re-arranging the number of PV modules and battery in the string.

  7. The structure of the clouds distributed operating system

    Science.gov (United States)

    Dasgupta, Partha; Leblanc, Richard J., Jr.

    1989-01-01

    A novel system architecture, based on the object model, is the central structuring concept used in the Clouds distributed operating system. This architecture makes Clouds attractive over a wide class of machines and environments. Clouds is a native operating system, designed and implemented at Georgia Tech. and runs on a set of generated purpose computers connected via a local area network. The system architecture of Clouds is composed of a system-wide global set of persistent (long-lived) virtual address spaces, called objects that contain persistent data and code. The object concept is implemented at the operating system level, thus presenting a single level storage view to the user. Lightweight treads carry computational activity through the code stored in the objects. The persistent objects and threads gives rise to a programming environment composed of shared permanent memory, dispensing with the need for hardware-derived concepts such as the file systems and message systems. Though the hardware may be distributed and may have disks and networks, the Clouds provides the applications with a logically centralized system, based on a shared, structured, single level store. The current design of Clouds uses a minimalist philosophy with respect to both the kernel and the operating system. That is, the kernel and the operating system support a bare minimum of functionality. Clouds also adheres to the concept of separation of policy and mechanism. Most low-level operating system services are implemented above the kernel and most high level services are implemented at the user level. From the measured performance of using the kernel mechanisms, we are able to demonstrate that efficient implementations are feasible for the object model on commercially available hardware. Clouds provides a rich environment for conducting research in distributed systems. Some of the topics addressed in this paper include distributed programming environments, consistency of persistent data

  8. Hardware-assisted software clock synchronization for homogeneous distributed systems

    Science.gov (United States)

    Ramanathan, P.; Kandlur, Dilip D.; Shin, Kang G.

    1990-01-01

    A clock synchronization scheme that strikes a balance between hardware and software solutions is proposed. The proposed is a software algorithm that uses minimal additional hardware to achieve reasonably tight synchronization. Unlike other software solutions, the guaranteed worst-case skews can be made insensitive to the maximum variation of message transit delay in the system. The scheme is particularly suitable for large partially connected distributed systems with topologies that support simple point-to-point broadcast algorithms. Examples of such topologies include the hypercube and the mesh interconnection structures.

  9. Zero-Voltage Ride-Through Capability of Single-Phase Grid-Connected Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2017-03-01

    Full Text Available Distributed renewable energy systems play an increasing role in today’s energy paradigm. Thus, intensive research activities have been centered on improving the performance of renewable energy systems, including photovoltaic (PV systems, which should be of multiple-functionality. That is, the PV systems should be more intelligent in the consideration of grid stability, reliability, and fault protection. Therefore, in this paper, the performance of single-phase grid-connected PV systems under an extreme grid fault (i.e., when the grid voltage dips to zero is explored. It has been revealed that combining a fast and accurate synchronization mechanism with appropriate control strategies for the zero-voltage ride-through (ZVRT operation is mandatory. Accordingly, the representative synchronization techniques (i.e., the phase-locked loop (PLL methods in the ZVRT operation are compared in terms of detection precision and dynamic response. It shows that the second-order generalized integrator (SOGI-PLL is a promising solution for single-phase systems in the case of fault ride-through. A control strategy by modifying the SOGI-PLL scheme is then introduced to single-phase grid-connected PV systems for ZVRT operation. Simulations are performed to verify the discussions. The results have demonstrated that the proposed method can help single-phase PV systems to temporarily ride through zero-voltage faults with good dynamics.

  10. Smart Distribution Systems

    Directory of Open Access Journals (Sweden)

    Yazhou Jiang

    2016-04-01

    Full Text Available The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. A comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD, is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs is introduced. Future research in a smart distribution environment is proposed.

  11. Simple clamped connection for bamboo truss systems

    NARCIS (Netherlands)

    Blok, R.

    2016-01-01

    “How to make fast and simple tension connections for truss systems?” The Solution: The innovation is a connection that uses only widely available base components (boltsand threaded steel bars) and simple hand tools to install it. With a handsaw and aspanner, the bamboo stems can be combined into to

  12. OpenID connect as a security service in Cloud-based diagnostic imaging systems

    Science.gov (United States)

    Ma, Weina; Sartipi, Kamran; Sharghi, Hassan; Koff, David; Bak, Peter

    2015-03-01

    The evolution of cloud computing is driving the next generation of diagnostic imaging (DI) systems. Cloud-based DI systems are able to deliver better services to patients without constraining to their own physical facilities. However, privacy and security concerns have been consistently regarded as the major obstacle for adoption of cloud computing by healthcare domains. Furthermore, traditional computing models and interfaces employed by DI systems are not ready for accessing diagnostic images through mobile devices. RESTful is an ideal technology for provisioning both mobile services and cloud computing. OpenID Connect, combining OpenID and OAuth together, is an emerging REST-based federated identity solution. It is one of the most perspective open standards to potentially become the de-facto standard for securing cloud computing and mobile applications, which has ever been regarded as "Kerberos of Cloud". We introduce OpenID Connect as an identity and authentication service in cloud-based DI systems and propose enhancements that allow for incorporating this technology within distributed enterprise environment. The objective of this study is to offer solutions for secure radiology image sharing among DI-r (Diagnostic Imaging Repository) and heterogeneous PACS (Picture Archiving and Communication Systems) as well as mobile clients in the cloud ecosystem. Through using OpenID Connect as an open-source identity and authentication service, deploying DI-r and PACS to private or community clouds should obtain equivalent security level to traditional computing model.

  13. Decentralized Observer with a Consensus Filter for Distributed Discrete-Time Linear Systems

    Science.gov (United States)

    Acikmese, Behcet; Mandic, Milan

    2011-01-01

    This paper presents a decentralized observer with a consensus filter for the state observation of a discrete-time linear distributed systems. In this setup, each agent in the distributed system has an observer with a model of the plant that utilizes the set of locally available measurements, which may not make the full plant state detectable. This lack of detectability is overcome by utilizing a consensus filter that blends the state estimate of each agent with its neighbors' estimates. We assume that the communication graph is connected for all times as well as the sensing graph. It is proven that the state estimates of the proposed observer asymptotically converge to the actual plant states under arbitrarily changing, but connected, communication and sensing topologies. As a byproduct of this research, we also obtained a result on the location of eigenvalues, the spectrum, of the Laplacian for a family of graphs with self-loops.

  14. Design of improved fuel cell controller for distributed generation systems

    Energy Technology Data Exchange (ETDEWEB)

    Olsen Berenguer, F.A. [Instituto de Energia Electrica, Universidad Nacional de San Juan, Av. Libertador San Martin Oeste, 1109, J5400ARL San Juan (Argentina); Molina, M.G. [CONICET, Instituto de Energia Electrica, Universidad Nacional de San Juan, Av. Libertador San Martin Oeste, 1109, J5400ARL San Juan (Argentina)

    2010-06-15

    The world has been undergoing a deregulation process which allowed competition in the electricity generation sector. This situation is bringing the opportunity for electricity users to generate power by using small-scale generation systems with emerging technologies, allowing the development of distributed generation (DG). A fuel cell power plant (FCPP) is a distributed generation technology with a rapid development because it has promising characteristics, such as low pollutant emissions, silent operation, high efficiency and long lifetime because of its small number of moving parts. The power conditioning system (PCS) is the interface that allows the effective connection to the electric power system. With the appropriate topology of the PCS and its control system design, the FCPP unit is capable of simultaneously performing both instantaneous active and reactive power flow control. This paper describes the design and implementation of a novel high performance PCS of an FCPP and its controller, for applications in distributed generation systems. A full detailed model of the FCPP is derived and a new three-level control scheme is designed. The dynamic performance of the proposed system is validated by digital simulation in SimPowerSystems (SPS) of MATLAB/Simulink. (author)

  15. Fault tolerant distributed real time computer systems for I and C of prototype fast breeder reactor

    Energy Technology Data Exchange (ETDEWEB)

    Manimaran, M., E-mail: maran@igcar.gov.in; Shanmugam, A.; Parimalam, P.; Murali, N.; Satya Murty, S.A.V.

    2014-03-15

    Highlights: • Architecture of distributed real time computer system (DRTCS) used in I and C of PFBR is explained. • Fault tolerant (hot standby) architecture, fault detection and switch over are detailed. • Scaled down model was used to study functional and performance requirements of DRTCS. • Quality of service parameters for scaled down model was critically studied. - Abstract: Prototype fast breeder reactor (PFBR) is in the advanced stage of construction at Kalpakkam, India. Three-tier architecture is adopted for instrumentation and control (I and C) of PFBR wherein bottom tier consists of real time computer (RTC) systems, middle tier consists of process computers and top tier constitutes of display stations. These RTC systems are geographically distributed and networked together with process computers and display stations. Hot standby architecture comprising of dual redundant RTC systems with switch over logic system is deployed in order to achieve fault tolerance. Fault tolerant dual redundant network connectivity is provided in each RTC system and TCP/IP protocol is selected for network communication. In order to assess the performance of distributed RTC systems, scaled down model was developed with 9 representative systems and nearly 15% of I and C signals of PFBR were connected and monitored. Functional and performance testing were carried out for each RTC system and the fault tolerant characteristics were studied by creating various faults into the system and observed the performance. Various quality of service parameters like connection establishment delay, priority parameter, transit delay, throughput, residual error ratio, etc., are critically studied for the network.

  16. Communication-based fault handling scheme for ungrounded distribution systems

    International Nuclear Information System (INIS)

    Yang, X.; Lim, S.I.; Lee, S.J.; Choi, M.S.

    2006-01-01

    The requirement for high quality and highly reliable power supplies has been increasing as a result of increasing demand for power. At the time of a fault occurrence in a distribution system, some protection method would be dedicated to fault section isolation and service restoration. However, if there are many outage areas when the protection method is performed, it is an inconvenience to the customer. A conventional method to determine a fault section in ungrounded systems requires many successive outage invocations. This paper proposed an efficient fault section isolation method and service restoration method for single line-to-ground fault in an ungrounded distribution system that was faster than the conventional one using the information exchange between connected feeders. The proposed algorithm could be performed without any power supply interruption and could decrease the number of switching operations, so that customers would not experience outages very frequently. The method involved the use of an intelligent communication method and a sequential switching control scheme. The proposed algorithm was also applied in both a single-tie and multi-tie distribution system. This proposed algorithm has been verified through fault simulations in a simple model of ungrounded multi-tie distribution system. The method proposed in this paper was proven to offer more efficient fault identification and much less outage time than the conventional method. The proposed method could contribute to a system design since it is valid in multi-tie systems. 5 refs., 2 tabs., 8 figs

  17. Efficient Gatherings in Wireless Sensor Networks Using Distributed Computation of Connected Dominating Sets

    Directory of Open Access Journals (Sweden)

    Vincent BOUDET

    2012-03-01

    Full Text Available In this paper, we are interested in enhancing lifetime of wireless sensor networks trying to collect data from all the nodes to a “sink”-node for non-safety critical applications. Connected Dominating Sets are used as a basis for routing messages to the sink. We present a simple distributed algorithm, which computes several CDS trying to distribute the consumption of energy over all the nodes of the network. The simulations show a significant improvement of the network lifetime.

  18. Connection between the growth rate distribution and the size dependent crystal growth

    Science.gov (United States)

    Mitrović, M. M.; Žekić, A. A.; IIić, Z. Z.

    2002-07-01

    The results of investigations of the connection between the growth rate dispersions and the size dependent crystal growth of potassium dihydrogen phosphate (KDP), Rochelle salt (RS) and sodium chlorate (SC) are presented. A possible way out of the existing confusion in the size dependent crystal growth investigations is suggested. It is shown that the size independent growth exists if the crystals belonging to one growth rate distribution maximum are considered separately. The investigations suggest possible reason for the observed distribution maxima widths, and the high data scattering on the growth rate versus the crystal size dependence.

  19. Fast Determination of Distribution-Connected PV Impacts Using a Variable Time-Step Quasi-Static Time-Series Approach: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Mather, Barry

    2017-08-24

    The increasing deployment of distribution-connected photovoltaic (DPV) systems requires utilities to complete complex interconnection studies. Relatively simple interconnection study methods worked well for low penetrations of photovoltaic systems, but more complicated quasi-static time-series (QSTS) analysis is required to make better interconnection decisions as DPV penetration levels increase. Tools and methods must be developed to support this. This paper presents a variable-time-step solver for QSTS analysis that significantly shortens the computational time and effort to complete a detailed analysis of the operation of a distribution circuit with many DPV systems. Specifically, it demonstrates that the proposed variable-time-step solver can reduce the required computational time by as much as 84% without introducing any important errors to metrics, such as the highest and lowest voltage occurring on the feeder, number of voltage regulator tap operations, and total amount of losses realized in the distribution circuit during a 1-yr period. Further improvement in computational speed is possible with the introduction of only modest errors in these metrics, such as a 91 percent reduction with less than 5 percent error when predicting voltage regulator operations.

  20. Accelerated Monte Carlo system reliability analysis through machine-learning-based surrogate models of network connectivity

    International Nuclear Information System (INIS)

    Stern, R.E.; Song, J.; Work, D.B.

    2017-01-01

    The two-terminal reliability problem in system reliability analysis is known to be computationally intractable for large infrastructure graphs. Monte Carlo techniques can estimate the probability of a disconnection between two points in a network by selecting a representative sample of network component failure realizations and determining the source-terminal connectivity of each realization. To reduce the runtime required for the Monte Carlo approximation, this article proposes an approximate framework in which the connectivity check of each sample is estimated using a machine-learning-based classifier. The framework is implemented using both a support vector machine (SVM) and a logistic regression based surrogate model. Numerical experiments are performed on the California gas distribution network using the epicenter and magnitude of the 1989 Loma Prieta earthquake as well as randomly-generated earthquakes. It is shown that the SVM and logistic regression surrogate models are able to predict network connectivity with accuracies of 99% for both methods, and are 1–2 orders of magnitude faster than using a Monte Carlo method with an exact connectivity check. - Highlights: • Surrogate models of network connectivity are developed by machine-learning algorithms. • Developed surrogate models can reduce the runtime required for Monte Carlo simulations. • Support vector machine and logistic regressions are employed to develop surrogate models. • Numerical example of California gas distribution network demonstrate the proposed approach. • The developed models have accuracies 99%, and are 1–2 orders of magnitude faster than MCS.

  1. Linear Power-Flow Models in Multiphase Distribution Networks: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, Andrey; Dall' Anese, Emiliano

    2017-05-26

    This paper considers multiphase unbalanced distribution systems and develops approximate power-flow models where bus-voltages, line-currents, and powers at the point of common coupling are linearly related to the nodal net power injections. The linearization approach is grounded on a fixed-point interpretation of the AC power-flow equations, and it is applicable to distribution systems featuring (i) wye connections; (ii) ungrounded delta connections; (iii) a combination of wye-connected and delta-connected sources/loads; and, (iv) a combination of line-to-line and line-to-grounded-neutral devices at the secondary of distribution transformers. The proposed linear models can facilitate the development of computationally-affordable optimization and control applications -- from advanced distribution management systems settings to online and distributed optimization routines. Performance of the proposed models is evaluated on different test feeders.

  2. Designing and Implementing a Distributed System Architecture for the Mars Rover Mission Planning Software (Maestro)

    Science.gov (United States)

    Goldgof, Gregory M.

    2005-01-01

    Distributed systems allow scientists from around the world to plan missions concurrently, while being updated on the revisions of their colleagues in real time. However, permitting multiple clients to simultaneously modify a single data repository can quickly lead to data corruption or inconsistent states between users. Since our message broker, the Java Message Service, does not ensure that messages will be received in the order they were published, we must implement our own numbering scheme to guarantee that changes to mission plans are performed in the correct sequence. Furthermore, distributed architectures must ensure that as new users connect to the system, they synchronize with the database without missing any messages or falling into an inconsistent state. Robust systems must also guarantee that all clients will remain synchronized with the database even in the case of multiple client failure, which can occur at any time due to lost network connections or a user's own system instability. The final design for the distributed system behind the Mars rover mission planning software fulfills all of these requirements and upon completion will be deployed to MER at the end of 2005 as well as Phoenix (2007) and MSL (2009).

  3. Computer aided planning of distribution systems and connection with medium term load forecast

    International Nuclear Information System (INIS)

    di Salvatore, F.; Grattieri, W.; Insinga, F.; Malafarina, L.; Mazzoni, M.; Nicola, G.

    1990-01-01

    In order to perform planning studies on HV (40-l50 kV), MV and LV networks, ENEL (Italian Electricity Board) has developed a computation system composed of a set of integrated programs which utilize the information stored in several data bases, with the aim of: providing energy consumption forecasts for each area of the country; transferring consumption for each area to the distribution network nodes and to evaluating the electric demand by using a statistical power/energy correlation model; analyzing several network development alternatives and selecting the optimum development plan by comparing the overall costs (investments, operation, risk). In order to make its utilization by planners easier, the computation system will be operated with interactive and graphic procedures made available by the use of graphic work stations. This report describes the main objectives and basic hypotheses assumed in the preparation of the computation system, as well as, the system's general architecture

  4. Zero-voltage ride-through capability of single-phase grid-connected photovoltaic systems

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Ma, Ruiqing

    2017-01-01

    Distributed renewable energy systems play an increasing role in today’s energy paradigm. Thus, intensive research activities have been centered on improving the performance of renewable energy systems, including photovoltaic (PV) systems, which should be of multiple-functionality. That is, the PV...... systems should be more intelligent in the consideration of grid stability, reliability, and fault protection. Therefore, in this paper, the performance of single-phase grid-connected PV systems under an extreme grid fault (i.e., when the grid voltage dips to zero) is explored. It has been revealed...... that combining a fast and accurate synchronization mechanism with appropriate control strategies for the zero-voltage ride-through (ZVRT) operation is mandatory. Accordingly, the representative synchronization techniques (i.e., the phase-locked loop (PLL) methods) in the ZVRT operation are compared in terms...

  5. Impact of Rural Grid-Connected Photovoltaic Generation Systems on Power Quality

    Directory of Open Access Journals (Sweden)

    Rita Pinto

    2016-09-01

    Full Text Available Photovoltaic (PV generation systems have been increasingly used to generate electricity from renewable sources, attracting a growing interest. Recently, grid connected PV micro-generation facilities in individual homes have increased due to governmental policies as well as greater attention by industry. As low voltage (LV distribution systems were built to make energy flow in one direction, the power feed-in of PV generation in rural low-voltage grids can influence power quality (PQ as well as facility operation and reliability. This paper presents results on PQ analysis of a real PV generation facility connected to a rural low-voltage grid. Voltage fluctuations and voltage harmonic contents were observed. Statistical analysis shows a negative impact on PQ produced by this PV facility and also that only a small fraction of the energy available during a sunny day is converted, provoking losses of revenue and forcing the converter to work in an undesirable operating mode. We discuss the disturbances imposed upon the grid and their outcome regarding technical and economic viability of the PV system, as well as possible solutions. A low-voltage grid strengthening has been suggested and implemented. After that a new PQ analysis shows an improvement in the impact upon PQ, making this facility economically viable.

  6. Methods, media and systems for managing a distributed application running in a plurality of digital processing devices

    Science.gov (United States)

    Laadan, Oren; Nieh, Jason; Phung, Dan

    2012-10-02

    Methods, media and systems for managing a distributed application running in a plurality of digital processing devices are provided. In some embodiments, a method includes running one or more processes associated with the distributed application in virtualized operating system environments on a plurality of digital processing devices, suspending the one or more processes, and saving network state information relating to network connections among the one or more processes. The method further include storing process information relating to the one or more processes, recreating the network connections using the saved network state information, and restarting the one or more processes using the stored process information.

  7. Process evaluation distributed system

    Science.gov (United States)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  8. A Simulation of Energy Storage System for Improving the Power System Stability with Grid-Connected PV using MCA Analysis and LabVIEW Tool

    Directory of Open Access Journals (Sweden)

    Jindrich Stuchly

    2015-01-01

    Full Text Available The large-scale penetration of distributed, Renewable power plants require transfers of large amounts of energy. This, in turn, puts a high strain on the energy delivery infrastructure. In particular, photovoltaic power plants supply energy with high intermittency, possibly affecting the stability of the grid by changing the voltage at the plant connection point. In this contribution, we summarize the main negative effects of selected and real-operated grid connected photovoltaic plant. Thereafter a review of suitable Energy storage systems to mitigate the negative effects has been carried out, compared and evaluated using Multi-criterion analysis. Based on this analysis, data collected at the plant and the grid, are used to design the energy storage systems to support connection of the plant to the grid. The cooperation of these systems is then analysed and evaluated using simulation tools created in LabVIEW for this purpose. The simulation results demonstrate the capability of energy storage system solutions to significantly reduce the negative feedback effects of Photovoltaic Power Plan to the low voltage grid.

  9. Distributed Secure Coordinated Control for Multiagent Systems Under Strategic Attacks.

    Science.gov (United States)

    Feng, Zhi; Wen, Guanghui; Hu, Guoqiang

    2017-05-01

    This paper studies a distributed secure consensus tracking control problem for multiagent systems subject to strategic cyber attacks modeled by a random Markov process. A hybrid stochastic secure control framework is established for designing a distributed secure control law such that mean-square exponential consensus tracking is achieved. A connectivity restoration mechanism is considered and the properties on attack frequency and attack length rate are investigated, respectively. Based on the solutions of an algebraic Riccati equation and an algebraic Riccati inequality, a procedure to select the control gains is provided and stability analysis is studied by using Lyapunov's method.. The effect of strategic attacks on discrete-time systems is also investigated. Finally, numerical examples are provided to illustrate the effectiveness of theoretical analysis.

  10. Economic Assessment of Network-Constrained Transactive Energy for Managing Flexible Demand in Distribution Systems

    Directory of Open Access Journals (Sweden)

    Junjie Hu

    2017-05-01

    Full Text Available The increasing number of distributed energy resources such as electric vehicles and heat pumps connected to power systems raises operational challenges to the network operator, for example, introducing grid congestion and voltage deviations in the distribution network level if their operations are not properly coordinated. Coordination and control of a large number of distributed energy resources requires innovative approaches. In this paper, we follow up on a recently proposed network-constrained transactive energy (NCTE method for scheduling of electric vehicles and heat pumps within a retailer’s aggregation at distribution system level. We extend this method with: (1 a new modeling technique that allows the resulting congestion price to be directly interpreted as a locational marginal pricing in the system; (2 an explicit analysis of the benefits and costs of different actors when using the NCTE method in the system, given the high penetration of distributed energy resources. This paper firstly describes the NCTE-based distribution system that introduces a new interacting scheme for actors at the distribution system level. Then, technical modeling and economic interpretation of the NCTE-based distribution system are described. Finally, we show the benefits and costs of different actors within the NCTE-based distribution system.

  11. Expansion connection of socket in flow distributed cabin of heavy water research reactor inner shell

    International Nuclear Information System (INIS)

    Jiang Zhiliang; Li Yanshui

    1995-01-01

    Expansion connection of aluminium alloy LT21 socket in flow distributed cabin of Heavy Water Research Reactor (HWRR) inner shell is described systematically. The expansion connection technology parameters of products are determined through tests. They are as following: bounce value of inner diameter after expansion, expansion degree, space between socket and plate hole, device for expanding pipes, selection of tools for enlarging or reaming holes, manufacture for socket inner hole and cleaning after expansion

  12. Grid-connected wind and photovoltaic system

    Science.gov (United States)

    Devabakthuni, Sindhuja

    The objective of this thesis is to design a grid connected wind and photovoltaic system. A new model of converter control was designed which maintains the voltage of the bus to grid as constant when combined system of solar and wind is connected to AC bus. The model is designed to track maximum power at each point irrespective of changes in irradiance, temperature and wind speed which affects the power supplied to grid. Solar power from the sun is not constant as it is affected by changes in irradiances and temperature. Even the wind power is affected by wind speed. A MPPT controller was designed for both systems. A boost converter is designed which uses the pulses from MPPT controller to boost the output. Wind system consists of wind turbine block from the MATLAB with a pitch angle controller to maintain optimum pitch angle. The output from wind turbine is connected to a permanent magnet synchronous generator. The unregulated DC output from the photovoltaic system is directly given to boost converter. The AC output from the wind system is given to an uncontrolled rectifier to get a unregulated DC output. The unregulated DC output goes to the boost converter. A voltage source inverter was designed which converts the rectified DC output from the boost converter to AC power. The inverter is designed to maintain constant AC bus voltage irrespective of the disturbances in the power supply. Photovoltaic and wind systems are individually designed for 5KW each in MATLAB-Simulink environment. In this thesis, the models were subjected to changes in irradiance, temperature and wind speed and the results were interpreted. The model was successful in tracking maximum at every instant and the AC bus voltage was maintained constant throughout the simulation.

  13. Modeling the distribution of dark matter and its connection to galaxies

    OpenAIRE

    Mao, Yao-Yuan

    2016-01-01

    Despite the mysterious nature of dark matter and dark energy, the Lambda-Cold Dark Matter (LCDM) model provides a reasonably accurate description of the evolution of the cosmos and the distribution of galaxies. Today, we are set to tackle more specific and quantitative questions about the galaxy formation physics, the nature of dark matter, and the connection between the dark and the visible components. The answers to these questions are however elusive, because dark matter is not directly ob...

  14. Nitrate, Nitrite, and Ammonium Variability in Drinking Water Distribution Systems.

    Science.gov (United States)

    Schullehner, Jörg; Stayner, Leslie; Hansen, Birgitte

    2017-03-09

    Accurate assessments of exposure to nitrate in drinking water is a crucial part of epidemiological studies investigating long-term adverse human health effects. However, since drinking water nitrate measurements are usually collected for regulatory purposes, assumptions on (1) the intra-distribution system variability and (2) short-term (seasonal) concentration variability have to be made. We assess concentration variability in the distribution system of nitrate, nitrite, and ammonium, and seasonal variability in all Danish public waterworks from 2007 to 2016. Nitrate concentrations at the exit of the waterworks are highly correlated with nitrate concentrations within the distribution net or at the consumers' taps, while nitrite and ammonium concentrations are generally lower within the net compared with the exit of the waterworks due to nitrification. However, nitrification of nitrite and ammonium in the distribution systems only results in a relatively small increase in nitrate concentrations. No seasonal variation for nitrate, nitrite, or ammonium was observed. We conclude that nitrate measurements taken at the exit of the waterworks are suitable to calculate exposures for all consumers connected to that waterworks and that sampling frequencies in the national monitoring programme are sufficient to describe temporal variations in longitudinal studies.

  15. Distributed processor systems

    International Nuclear Information System (INIS)

    Zacharov, B.

    1976-01-01

    In recent years, there has been a growing tendency in high-energy physics and in other fields to solve computational problems by distributing tasks among the resources of inter-coupled processing devices and associated system elements. This trend has gained further momentum more recently with the increased availability of low-cost processors and with the development of the means of data distribution. In two lectures, the broad question of distributed computing systems is examined and the historical development of such systems reviewed. An attempt is made to examine the reasons for the existence of these systems and to discern the main trends for the future. The components of distributed systems are discussed in some detail and particular emphasis is placed on the importance of standards and conventions in certain key system components. The ideas and principles of distributed systems are discussed in general terms, but these are illustrated by a number of concrete examples drawn from the context of the high-energy physics environment. (Auth.)

  16. Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid

    Directory of Open Access Journals (Sweden)

    Jong-Chan Choi

    2014-10-01

    Full Text Available Direct Current (DC microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a building microgrid. Therefore, a new control method is needed for a middle or large scale DC microgrid. This paper analyzes voltage drop problems in a large DC microgrid and proposes a cooperative voltage control scheme with a distributed generator (DG and a grid connected converter (GCC. For the voltage control with DGs, their location and capacity should be considered for economic operation in the systems. Accordingly, an optimal DG allocation algorithm is proposed to minimize the capacity of a DG for voltage control in DC microgrids. The proposed methods are verified with typical load types by a simulation using MATLAB and PSCAD/EMTDC.

  17. Spreading Sequence System for Full Connectivity Relay Network

    Science.gov (United States)

    Kwon, Hyuck M. (Inventor); Yang, Jie (Inventor); Pham, Khanh D. (Inventor)

    2018-01-01

    Fully connected uplink and downlink fully connected relay network systems using pseudo-noise spreading and despreading sequences subjected to maximizing the signal-to-interference-plus-noise ratio. The relay network systems comprise one or more transmitting units, relays, and receiving units connected via a communication network. The transmitting units, relays, and receiving units each may include a computer for performing the methods and steps described herein and transceivers for transmitting and/or receiving signals. The computer encodes and/or decodes communication signals via optimum adaptive PN sequences found by employing Cholesky decompositions and singular value decompositions (SVD). The PN sequences employ channel state information (CSI) to more effectively and more securely computing the optimal sequences.

  18. The Clouds distributed operating system - Functional description, implementation details and related work

    Science.gov (United States)

    Dasgupta, Partha; Leblanc, Richard J., Jr.; Appelbe, William F.

    1988-01-01

    Clouds is an operating system in a novel class of distributed operating systems providing the integration, reliability, and structure that makes a distributed system usable. Clouds is designed to run on a set of general purpose computers that are connected via a medium-of-high speed local area network. The system structuring paradigm chosen for the Clouds operating system, after substantial research, is an object/thread model. All instances of services, programs and data in Clouds are encapsulated in objects. The concept of persistent objects does away with the need for file systems, and replaces it with a more powerful concept, namely the object system. The facilities in Clouds include integration of resources through location transparency; support for various types of atomic operations, including conventional transactions; advanced support for achieving fault tolerance; and provisions for dynamic reconfiguration.

  19. Hybrid Systems of Distributed Generation with Renewable Sources: Modeling and Analysis of Their Operational Modes in Electric Power System

    Directory of Open Access Journals (Sweden)

    A. M. Gashimov

    2013-01-01

    Full Text Available The paper considers problems pertaining to modeling and simulation of operational hybrid system modes of the distributed generation comprising conventional sources – modular diesel generators, gas-turbine power units; and renewable sources – wind and solar power plants. Operational modes of the hybrid system have been investigated under conditions of electrical connection with electric power system and in case of its isolated operation. As a consequence

  20. Deterministic Properties of Serially Connected Distributed Lag Models

    Directory of Open Access Journals (Sweden)

    Piotr Nowak

    2013-01-01

    Full Text Available Distributed lag models are an important tool in modeling dynamic systems in economics. In the analysis of composite forms of such models, the component models are ordered in parallel (with the same independent variable and/or in series (where the independent variable is also the dependent variable in the preceding model. This paper presents an analysis of certain deterministic properties of composite distributed lag models composed of component distributed lag models arranged in sequence, and their asymptotic properties in particular. The models considered are in discrete form. Even though the paper focuses on deterministic properties of distributed lag models, the derivations are based on analytical tools commonly used in probability theory such as probability distributions and the central limit theorem. (original abstract

  1. Condensate clean up control system with distributed DDC

    International Nuclear Information System (INIS)

    Yoshioka, K.; Tazima, T.; Nakamura, O.; Kobayashi, S.

    1980-01-01

    In the operation of the Condensate Clean Up System in BWR plants, regeneration intervals of the demineralizer are not equal and there is no base to determine the interval, which is usually decided by operator's experience. Regeneration of resin is, therefore, sometimes performed too early, leaving much of the capacity of the resin unused. In order to improve such operations efforts were made to equalize the operating time difference of two sequential demineralizers, to control the initial flow into newly-connected demineralizers. The economic and efficient operation of this system, along with the reduction of radioactive resins and the safety supervisory function can be achieved by the distributed DDC with a microprocessor. (LL)

  2. Micro-generation network connection (renewables)

    Energy Technology Data Exchange (ETDEWEB)

    Thornycroft, J.; Russell, T.; Curran, J.

    2003-07-01

    The drive to reduce emissions of carbon dioxide will result in an increase in the number of small generation units seeking connection to the electric power distribution network. The objectives of this study were to consider connection issues relating to micro-generation from renewables and their integration into the UK distribution network. The document is divided into two sections. The first section describes the present system which includes input from micro-generation, the technical impacts and the financial considerations. The second part discusses technical, financial and governance options for the future. A summary of preferred options and recommendations is given. The study was carried out by the Halcrow Group Ltd under contract to the DTI.

  3. Design, modeling, simulation and evaluation of a distributed energy system

    Science.gov (United States)

    Cultura, Ambrosio B., II

    This dissertation presents the design, modeling, simulation and evaluation of distributed energy resources (DER) consisting of photovoltaics (PV), wind turbines, batteries, a PEM fuel cell and supercapacitors. The distributed energy resources installed at UMass Lowell consist of the following: 2.5kW PV, 44kWhr lead acid batteries and 1500W, 500W & 300W wind turbines, which were installed before year 2000. Recently added to that are the following: 10.56 kW PV array, 2.4 kW wind turbine, 29 kWhr Lead acid batteries, a 1.2 kW PEM fuel cell and 4-140F supercapacitors. Each newly added energy resource has been designed, modeled, simulated and evaluated before its integration into the existing PV/Wind grid-connected system. The Mathematical and Simulink model of each system was derived and validated by comparing the simulated and experimental results. The Simulated results of energy generated from a 10.56kW PV system are in good agreement with the experimental results. A detailed electrical model of a 2.4kW wind turbine system equipped with a permanent magnet generator, diode rectifier, boost converter and inverter is presented. The analysis of the results demonstrates the effectiveness of the constructed simulink model, and can be used to predict the performance of the wind turbine. It was observed that a PEM fuel cell has a very fast response to load changes. Moreover, the model has validated the actual operation of the PEM fuel cell, showing that the simulated results in Matlab Simulink are consistent with the experimental results. The equivalent mathematical equation, derived from an electrical model of the supercapacitor, is used to simulate its voltage response. The model is completely capable of simulating its voltage behavior, and can predict the charge time and discharge time of voltages on the supercapacitor. The bi-directional dc-dc converter was designed in order to connect the 48V battery bank storage to the 24V battery bank storage. This connection was

  4. Transactive control: a framework for operating power systems characterized by high penetration of distributed energy resources

    DEFF Research Database (Denmark)

    Hu, Junjie; Yang, Guangya; Kok, Koen

    2016-01-01

    The increasing number of distributed energy resources connected to power systems raises operational challenges for the network operator, such as introducing grid congestion and voltage deviations in the distribution network level, as well as increasing balancing needs at the whole system level......, followed by a literature review and demonstration projects that apply to transactive control. Cases are then presented to illustrate the transactive control framework. At the end, discussions and research directions are presented, for applying transactive control to operating power systems, characterized...

  5. Handbook of Brain Connectivity

    CERN Document Server

    Jirsa, Viktor K

    2007-01-01

    Our contemporary understanding of brain function is deeply rooted in the ideas of the nonlinear dynamics of distributed networks. Cognition and motor coordination seem to arise from the interactions of local neuronal networks, which themselves are connected in large scales across the entire brain. The spatial architectures between various scales inevitably influence the dynamics of the brain and thereby its function. But how can we integrate brain connectivity amongst these structural and functional domains? Our Handbook provides an account of the current knowledge on the measurement, analysis and theory of the anatomical and functional connectivity of the brain. All contributors are leading experts in various fields concerning structural and functional brain connectivity. In the first part of the Handbook, the chapters focus on an introduction and discussion of the principles underlying connected neural systems. The second part introduces the currently available non-invasive technologies for measuring struct...

  6. Distributed Ship Navigation Control System Based on Dual Network

    Science.gov (United States)

    Yao, Ying; Lv, Wu

    2017-10-01

    Navigation system is very important for ship’s normal running. There are a lot of devices and sensors in the navigation system to guarantee ship’s regular work. In the past, these devices and sensors were usually connected via CAN bus for high performance and reliability. However, as the development of related devices and sensors, the navigation system also needs the ability of high information throughput and remote data sharing. To meet these new requirements, we propose the communication method based on dual network which contains CAN bus and industrial Ethernet. Also, we import multiple distributed control terminals with cooperative strategy based on the idea of synchronizing the status by multicasting UDP message contained operation timestamp to make the system more efficient and reliable.

  7. High-Efficiency High Step-Up DC-DC Converter with Dual Coupled Inductors for Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Shen, Yanfeng; Siwakoti, Yam Prasad

    2018-01-01

    with a common ground connection of the input and output make the proposed topology a proper candidate for a transformer-less grid connected photovoltaic systems. The operating performance, analysis and mathematical derivations of the proposed dc-dc converter have been demonstrated in the paper. Moreover......This paper introduces a non-isolated high step-up dc-dc converter with dual coupled inductors suitable for distributed generation applications. By implementing an input parallel connection, the proposed dc-dc structure inherits shared input current with low ripple, which also requires small...... capacitive filter at its input. Moreover, this topology can reach high voltage gain by using dual coupled inductors in series connection at the output stage. The proposed converter uses active clamp circuits with a shared clamp capacitor for the main switches. In addition to the active clamp circuit...

  8. Development of a VxWorks-based distributed power quality monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Shin, M.J.; Kim, S.J.; Son, Y.I.; Kang, S.H. [Myongji Univ., Yongin (Korea, Republic of). Next-generation Power Technology Center

    2007-07-01

    Electric utilities are becoming increasingly concerned about power quality because end user equipment is more sensitive to disturbances within the power supply system and also within the consumer facilities. In order to improve the quality of electricity, the sources and causes of disturbances must be known. However, voltage sag and swell, wave-faults and momentary interruptions are difficult to detect and avoid unless power quality monitoring devices are installed permanently. The impact that alternative energy sources have on power quality was also discussed. When distributed generation is connected to the power grid, it can generate and supply more reliable power to the grid. For a reliable interconnection of distributed power to the grid, monitoring systems should display the status of distributed power and record power events. Lack of source stability in distributed generation such as solar-cells or wind-power creates events that should be measured and stored immediately. This paper presented a newly developed real-time power quality monitoring system for distributed power systems. The system is based on a real-time operating system (OS) and can therefore handle many events that happen simultaneously. The proposed system contains a digital signal processor (MPC7410, Motorola) and an A/D board (VMIVME3122, GE). VxWorks was used to implement the monitoring algorithm. This paper outlined the structure and the functions of the developed Distributed Power Quality Monitoring System. Some experiments were conducted to test the performance of the proposed system. According to test results, the system is compatible with standards of the Institute of Electrical and Electronics Engineers (IEEE) for power quality monitoring. 15 refs., 1 tab., 18 figs.

  9. Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection

    Directory of Open Access Journals (Sweden)

    M. Kasagi

    2016-02-01

    Full Text Available A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and investigated. In this new hybrid building system, a base-isolated building is connected to a stiffer free wall with oil dampers. It has been demonstrated in a preliminary research that the proposed hybrid system is effective both for near-fault (rather high-frequency and long-duration, long-period earthquake ground motions and has sufficient redundancy and robustness for a broad range of earthquake ground motions.An automatic generation algorithm of this kind of smart structures of base-isolation and building-connection hybrid systems is presented in this paper. It is shown that, while the proposed algorithm does not work well in a building without the connecting-damper system, it works well in the proposed smart hybrid system with the connecting damper system.

  10. Electric distribution systems

    CERN Document Server

    Sallam, A A

    2010-01-01

    "Electricity distribution is the penultimate stage in the delivery of electricity to end users. The only book that deals with the key topics of interest to distribution system engineers, Electric Distribution Systems presents a comprehensive treatment of the subject with an emphasis on both the practical and academic points of view. Reviewing traditional and cutting-edge topics, the text is useful to practicing engineers working with utility companies and industry, undergraduate graduate and students, and faculty members who wish to increase their skills in distribution system automation and monitoring."--

  11. Distributed Control in Multi-Vehicle Systems

    Directory of Open Access Journals (Sweden)

    Paul A. Avery

    2013-12-01

    Full Text Available The Southwest Research Institute (SwRI Mobile Autonomous Robotics Technology Initiative (MARTI program has enabled the development of fully-autonomous passenger-sized commercial vehicles and military tactical vehicles, as well as the development of cooperative vehicle behaviors, such as cooperative sensor sharing and cooperative convoy operations. The program has also developed behaviors to interface intelligent vehicles with intelligent road-side devices. The development of intelligent vehicle behaviors cannot be approached as stand-alone phenomena; rather, they must be understood within a context of the broader traffic system dynamics. The study of other complex systems has shown that system-level behaviors emerge as a result of the spatio-temporal dynamics within a system's constituent parts. The design of such systems must therefore account for both the system-level emergent behavior, as well as behaviors of individuals within the system. It has also become clear over the past several years, for both of these domains, that human trust in the behavior of individual vehicles is paramount to broader technology adoption. This paper examines the interplay between individual vehicle capabilities, vehicle connectivity, and emergent system behaviors, and presents some considerations for a distributed control paradigm in a multi-vehicle system.

  12. Data Distribution Service for Industrial Automation

    OpenAIRE

    Yang, Jinsong

    2012-01-01

    In industrial automation systems, there is usually large volume of data which needs to be delivered to right places at the right time. In addition, large number of nodes in the automation systems are usually distributed which increases the complexity that there needs to be more point-to-point Ethernet-connections in the network. Hence, it is necessary to apply data-centric design and reduce the connection complexity. Data Distributed Service for Real-Time Systems (DDS) is a data-centric middl...

  13. A Distributed Synchronization and Timing System on the EAST Tokamak

    Science.gov (United States)

    Luo, Jiarong; Wu, Yichun; Shu, Yantai

    2008-08-01

    A key requirement for the EAST distributed control system (EASTDCS) is time synchronization to an accuracy of RTOS). The DSTS provides the control and the data acquisition systems with reference clocks (0.01 Hz 10 MHz) and delayed trigger times ( 1 mus 4294 s). These are produced by a Core Module Unit (CMU) connected by optical fibres to many Local Synchronized Node Units (LSNU). The fibres provide immunity from electrical noise and are of equal length to match clock and trigger delays between systems. This paper describes the architecture of the DSTS on the EAST tokamak and provides an overview of the characteristics of the main and local units.

  14. Study on introduction of SN transition type FCL into looped distribution system

    International Nuclear Information System (INIS)

    Kameda, Hideyuki; Uemura, Satoshi; Ichinose, Ataru

    2012-01-01

    A large amount of distributed generations such as PV will be introduced into the future Japanese distribution systems. Although distribution systems are presently operated under radial configuration and are terminated with loads, the connection of the distributed generations may cause some problems such as the occurrence of reverse power, the sensitivity decrease of the protection relays, and the voltage rise at the ends. It is assumed that a distribution system is looped in a large city to aim at the improvement of the service reliability under the situation mentioned above. However, a countermeasure against the increase of short-circuit current may be necessary in a looped system. We think that the installation of the SN transition type superconducting fault current limiter (FCL) is effective as a measure against the increase of short-circuit capacity, so we have proposed an effective arrangement of the FCLs into a radial distribution system and the method of setting the parameters. In this paper, a new introduction of FCLs is proposed, that is the way to clear a short-circuit fault within a looped system by the protection relay and the loop switch (LS). To achieve this purpose, the FCL needs to reduce the current through the LS below the rated current of the LS. And we propose the best arrangement to achieve the purpose, and the method of setting the parameters of a SN transition type FCL. Our proposal may bring the flexibility of composing any system configuration.

  15. Distributed Data Management and Distributed File Systems

    CERN Document Server

    Girone, Maria

    2015-01-01

    The LHC program has been successful in part due to the globally distributed computing resources used for collecting, serving, processing, and analyzing the large LHC datasets. The introduction of distributed computing early in the LHC program spawned the development of new technologies and techniques to synchronize information and data between physically separated computing centers. Two of the most challenges services are the distributed file systems and the distributed data management systems. In this paper I will discuss how we have evolved from local site services to more globally independent services in the areas of distributed file systems and data management and how these capabilities may continue to evolve into the future. I will address the design choices, the motivations, and the future evolution of the computing systems used for High Energy Physics.

  16. Connect Global Positioning System RF Module

    Science.gov (United States)

    Franklin, Garth W.; Young, Lawrence E.; Ciminera, Michael A.; Tien, Jeffrey Y.; Gorelik, Jacob; Okihiro, Brian Bachman; Koelewyn, Cynthia L.

    2012-01-01

    The CoNNeCT Global Positioning System RF Module (GPSM) slice is part of the JPL CoNNeCT Software Defined Radio (SDR). CoNNeCT is the Communications, Navigation, and Net working reconfigurable Testbed project that is part of NASA's Space Communication and Nav igation (SCaN) Program. The CoNNeCT project is an experimental dem onstration that will lead to the advancement of SDRs and provide a path for new space communication and navigation systems for future NASA exploration missions. The JPL CoNNeCT SDR will be flying on the International Space Station (ISS) in 2012 in support of the SCaN CoNNeCT program. The GPSM is a radio-frequency sampler module (see Figure 1) that directly sub-harmonically samples the filtered GPS L-band signals at L1 (1575.42 MHz), L2 (1227.6 MHz), and L5 (1176.45 MHz). The JPL SDR receives GPS signals through a Dorne & Margolin antenna mounted onto a choke ring. The GPS signal is filtered against interference, amplified, split, and fed into three channels: L1, L2, and L5. In each of the L-band channels, there is a chain of bandpass filters and amplifiers, and the signal is fed through each of these channels to where the GPSM performs a one-bit analog-to-digital conversion (see Figure 2). The GPSM uses a sub-harmonic, single-bit L1, L2, and L5 sampler that samples at a clock rate of 38.656 MHz. The new capability is the down-conversion and sampling of the L5 signal when previous hardware did not provide this capability. The first GPS IIF Satellite was launched in 2010, providing the new L5 signal. With the JPL SDR flying on the ISS, it will be possible to demonstrate navigation solutions with 10-meter 3-D accuracy at 10-second intervals using a field-program mable gate array (FPGA)-based feedback loop running at 50 Hz. The GPS data bits will be decoded and used in the SDR. The GPSM will also allow other waveforms that are installed in the SDR to demonstrate various GNSS tracking techniques.

  17. Medial vestibular connections with the hypocretin (orexin) system

    Science.gov (United States)

    Horowitz, Seth S.; Blanchard, Jane; Morin, Lawrence P.

    2005-01-01

    The mammalian medial vestibular nucleus (MVe) receives input from all vestibular endorgans and provides extensive projections to the central nervous system. Recent studies have demonstrated projections from the MVe to the circadian rhythm system. In addition, there are known projections from the MVe to regions considered to be involved in sleep and arousal. In this study, afferent and efferent subcortical connectivity of the medial vestibular nucleus of the golden hamster (Mesocricetus auratus) was evaluated using cholera toxin subunit-B (retrograde), Phaseolus vulgaris leucoagglutinin (anterograde), and pseudorabies virus (transneuronal retrograde) tract-tracing techniques. The results demonstrate MVe connections with regions mediating visuomotor and postural control, as previously observed in other mammals. The data also identify extensive projections from the MVe to regions mediating arousal and sleep-related functions, most of which receive immunohistochemically identified projections from the lateral hypothalamic hypocretin (orexin) neurons. These include the locus coeruleus, dorsal and pedunculopontine tegmental nuclei, dorsal raphe, and lateral preoptic area. The MVe itself receives a projection from hypocretin cells. CTB tracing demonstrated reciprocal connections between the MVe and most brain areas receiving MVe efferents. Virus tracing confirmed and extended the MVe afferent connections identified with CTB and additionally demonstrated transneuronal connectivity with the suprachiasmatic nucleus and the medial habenular nucleus. These anatomical data indicate that the vestibular system has access to a broad array of neural functions not typically associated with visuomotor, balance, or equilibrium, and that the MVe is likely to receive information from many of the same regions to which it projects.

  18. An improved current control scheme for grid-connected DG unit based distribution system harmonic compensation

    DEFF Research Database (Denmark)

    He, Jinwei; Wei Li, Yun; Wang, Xiongfei

    2013-01-01

    In order to utilize DG unit interfacing converters to actively compensate distribution system harmonics, this paper proposes an enhanced current control approach. It seamlessly integrates system harmonic mitigation capabilities with the primary DG power generation function. As the proposed current...... controller has two well decoupled control branches to independently control fundamental and harmonic DG currents, phase-locked loops (PLL) and system harmonic component extractions can be avoided during system harmonic compensation. Moreover, a closed-loop power control scheme is also employed to derive...... the fundamental current reference. The proposed power control scheme effectively eliminates the impacts of steady-state fundamental current tracking errors in the DG units. Thus, an accurate power control is realized even when the harmonic compensation functions are activated. Experimental results from a single...

  19. Abnormally Malicious Autonomous Systems and their Internet Connectivity

    Energy Technology Data Exchange (ETDEWEB)

    Shue, Craig A [ORNL; Kalafut, Prof. Andrew [Grand Valley State University (GVSU), Michigan; Gupta, Prof. Minaxi [Indiana University

    2011-01-01

    While many attacks are distributed across botnets, investigators and network operators have recently targeted malicious networks through high profile autonomous system (AS) de-peerings and network shut-downs. In this paper, we explore whether some ASes indeed are safe havens for malicious activity. We look for ISPs and ASes that exhibit disproportionately high malicious behavior using ten popular blacklists, plus local spam data, and extensive DNS resolutions based on the contents of the blacklists. We find that some ASes have over 80% of their routable IP address space blacklisted. Yet others account for large fractions of blacklisted IP addresses. Several ASes regularly peer with ASes associated with significant malicious activity. We also find that malicious ASes as a whole differ from benign ones in other properties not obviously related to their malicious activities, such as more frequent connectivity changes with their BGP peers. Overall, we conclude that examining malicious activity at AS granularity can unearth networks with lax security or those that harbor cybercrime.

  20. Clustering analysis of water distribution systems: identifying critical components and community impacts.

    Science.gov (United States)

    Diao, K; Farmani, R; Fu, G; Astaraie-Imani, M; Ward, S; Butler, D

    2014-01-01

    Large water distribution systems (WDSs) are networks with both topological and behavioural complexity. Thereby, it is usually difficult to identify the key features of the properties of the system, and subsequently all the critical components within the system for a given purpose of design or control. One way is, however, to more explicitly visualize the network structure and interactions between components by dividing a WDS into a number of clusters (subsystems). Accordingly, this paper introduces a clustering strategy that decomposes WDSs into clusters with stronger internal connections than external connections. The detected cluster layout is very similar to the community structure of the served urban area. As WDSs may expand along with urban development in a community-by-community manner, the correspondingly formed distribution clusters may reveal some crucial configurations of WDSs. For verification, the method is applied to identify all the critical links during firefighting for the vulnerability analysis of a real-world WDS. Moreover, both the most critical pipes and clusters are addressed, given the consequences of pipe failure. Compared with the enumeration method, the method used in this study identifies the same group of the most critical components, and provides similar criticality prioritizations of them in a more computationally efficient time.

  1. An Integrated Conceptual Environment based on Collective Intelligence and Distributed Artificial Intelligence for Connecting People on Problem Solving

    Directory of Open Access Journals (Sweden)

    Vasile MAZILESCU

    2012-12-01

    Full Text Available This paper aims to analyze the different forms of intelligence within organizations in a systemic and inclusive vision, in order to conceptualize an integrated environment based on Distributed Artificial Intelligence (DAI and Collective Intelligence (CI. In this way we effectively shift the classical approaches of connecting people with people using collaboration tools (which allow people to work together, such as videoconferencing or email, groupware in virtual space, forums, workflow, of connecting people with a series of content management knowledge (taxonomies and documents classification, ontologies or thesauri, search engines, portals, to the current approaches of connecting people on the use (automatic of operational knowledge to solve problems and make decisions based on intellectual cooperation. The best way to use collective intelligence is based on knowledge mobilization and semantic technologies. We must not let computers to imitate people but to support people think and develop their ideas within a group. CI helps people to think together, while DAI tries to support people so as to limit human error. Within an organization, to manage CI is to combine instruments like Semantic Technologies (STs, knowledge mobilization methods for developing Knowledge Management (KM strategies, and the processes that promote connection and collaboration between individual minds in order to achieve collective objectives, to perform a task or to solve increasingly economic complex problems.

  2. Dynamic functional brain connectivity for face perception

    NARCIS (Netherlands)

    Yang, Yuan; Qiu, Yihong; Schouten, Alfred C.

    2015-01-01

    Face perception is mediated by a distributed brain network comprised of the core system at occipito-temporal areas and the extended system at other relevant brain areas involving bilateral hemispheres. In this study we explored how the brain connectivity changes over the time for face-sensitive

  3. Grid-connected photovoltaic power systems: survey of inverter and related protection equipments

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T

    2002-12-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme reports on a survey made on inverter and related protection equipment. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This report summarises the data obtained from survey of recent inverter technology and inverter protection equipment for grid interconnected PV systems. The results are based on the surveys using a questionnaire to identify the current status of grid-interconnection inverters. This report is to serve as a reference for those interested in installing grid-connected PV systems, electric utility company personnel, manufacturers and researchers. The results of the survey are presented and discussed. Technical and financial data is reviewed and two appendices provide details on the results obtained and those institutions involved in the survey.

  4. A single phase photovoltaic inverter control for grid connected system

    Indian Academy of Sciences (India)

    This paper presents a control scheme for single phase grid connected photovoltaic (PV) system operating under both grid connected and isolated grid mode. The control techniques include voltage and current control of grid-tie PV inverter. During grid connected mode, grid controls the amplitude and frequency of the PV ...

  5. Adaptive decoupled power control method for inverter connected DG

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Tian, Yanjun; Chen, Zhe

    2014-01-01

    an adaptive droop control method based on online evaluation of power decouple matrix for inverter connected distributed generations in distribution system. Traditional decoupled power control is simply based on line impedance parameter, but the load characteristics also cause the power coupling, and alter...

  6. Optimizing electrical load pattern in Kuwait using grid connected photovoltaic systems

    International Nuclear Information System (INIS)

    Al-Hasan, A.Y.; Ghoneim, A.A.; Abdullah, A.H.

    2004-01-01

    Grid connected photovoltaic systems is one of the most promising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because grid power may be used to supplement photovoltaic systems (PV) when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility grid. In this system, the load is the total electrical energy consumption. The main objective of the present work is to optimize the electrical load pattern in Kuwait using grid connected PV systems. In this situation, the electric load demand can be satisfied from both the photovoltaic array and the utility grid. The performance of grid connected photovoltaic systems in the Kuwait climate has been evaluated. It was found that the peak load matches the maximum incident solar radiation in Kuwait, which would emphasize the role of using the PV station to minimize the electrical load demand. In addition, a significant reduction in peak load can be achieved with grid connected PV systems

  7. A multi-agent system for distribution grid congestion management with electric vehicles

    DEFF Research Database (Denmark)

    Hu, Junjie; Saleem, Arshad; You, Shi

    2015-01-01

    Electric vehicles (EVs) are widely regarded as valuable assets in the smart grid as distributed energy resources in addition to their primary transportation function. However, connecting EVs to the distribution network and recharging the EV batteries without any control may overload the transform......Electric vehicles (EVs) are widely regarded as valuable assets in the smart grid as distributed energy resources in addition to their primary transportation function. However, connecting EVs to the distribution network and recharging the EV batteries without any control may overload...

  8. A two-stage stochastic programming model for the optimal design of distributed energy systems

    International Nuclear Information System (INIS)

    Zhou, Zhe; Zhang, Jianyun; Liu, Pei; Li, Zheng; Georgiadis, Michael C.; Pistikopoulos, Efstratios N.

    2013-01-01

    Highlights: ► The optimal design of distributed energy systems under uncertainty is studied. ► A stochastic model is developed using genetic algorithm and Monte Carlo method. ► The proposed system possesses inherent robustness under uncertainty. ► The inherent robustness is due to energy storage facilities and grid connection. -- Abstract: A distributed energy system is a multi-input and multi-output energy system with substantial energy, economic and environmental benefits. The optimal design of such a complex system under energy demand and supply uncertainty poses significant challenges in terms of both modelling and corresponding solution strategies. This paper proposes a two-stage stochastic programming model for the optimal design of distributed energy systems. A two-stage decomposition based solution strategy is used to solve the optimization problem with genetic algorithm performing the search on the first stage variables and a Monte Carlo method dealing with uncertainty in the second stage. The model is applied to the planning of a distributed energy system in a hotel. Detailed computational results are presented and compared with those generated by a deterministic model. The impacts of demand and supply uncertainty on the optimal design of distributed energy systems are systematically investigated using proposed modelling framework and solution approach.

  9. Network reconfiguration for loss reduction in electrical distribution system using genetic algorithm

    International Nuclear Information System (INIS)

    Adail, A.S.A.A.

    2012-01-01

    Distribution system is a critical links between the utility and the nuclear installation. During feeding electricity to that installation there are power losses. The quality of the network depends on the reduction of these losses. Distribution system which feeds the nuclear installation must have a higher quality power. For example, in Inshas site, electrical power is supplied to it from two incoming feeders (one from new abu-zabal substation and the other from old abu-zabal substation). Each feeder is designed to carry the full load, while the operator preferred to connect with a new abu-zabal substation, which has a good power quality. Bad power quality affects directly the nuclear reactor and has a negative impact on the installed sensitive equipment's of the operation. The thesis is Studying the electrical losses in a distribution system (causes and effected factors), feeder reconfiguration methods, and applying of genetic algorithm in an electric distribution power system. In the end, this study proposes an optimization technique based on genetic algorithms for distribution network reconfiguration to reduce the network losses to minimum. The proposed method is applied to IEEE test network; that contain 3 feeders and 16 nodes. The technique is applied through two groups, distribution have general loads, and nuclear loads. In the groups the technique applied to seven cases at normal operation state, system fault condition as well as different loads conditions. Simulated results are drawn to show the accuracy of the technique.

  10. Watershed erosion modeling using the probability of sediment connectivity in a gently rolling system

    Science.gov (United States)

    Mahoney, David Tyler; Fox, James Forrest; Al Aamery, Nabil

    2018-06-01

    Sediment connectivity has been shown in recent years to explain how the watershed configuration controls sediment transport. However, we find no studies develop a watershed erosion modeling framework based on sediment connectivity, and few, if any, studies have quantified sediment connectivity for gently rolling systems. We develop a new predictive sediment connectivity model that relies on the intersecting probabilities for sediment supply, detachment, transport, and buffers to sediment transport, which is integrated in a watershed erosion model framework. The model predicts sediment flux temporally and spatially across a watershed using field reconnaissance results, a high-resolution digital elevation models, a hydrologic model, and shear-based erosion formulae. Model results validate the capability of the model to predict erosion pathways causing sediment connectivity. More notably, disconnectivity dominates the gently rolling watershed across all morphologic levels of the uplands, including, microtopography from low energy undulating surfaces across the landscape, swales and gullies only active in the highest events, karst sinkholes that disconnect drainage areas, and floodplains that de-couple the hillslopes from the stream corridor. Results show that sediment connectivity is predicted for about 2% or more the watershed's area 37 days of the year, with the remaining days showing very little or no connectivity. Only 12.8 ± 0.7% of the gently rolling watershed shows sediment connectivity on the wettest day of the study year. Results also highlight the importance of urban/suburban sediment pathways in gently rolling watersheds, and dynamic and longitudinal distributions of sediment connectivity might be further investigated in future work. We suggest the method herein provides the modeler with an added tool to account for sediment transport criteria and has the potential to reduce computational costs in watershed erosion modeling.

  11. Development and Testing of Protection Scheme for Renewable-Rich Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    Brahma, Sukumar [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ranade, Satish [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Elkhatib, Mohamed E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reno, Matthew J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    As the penetration of renewables increases in the distribution systems, and microgrids are conceived with high penetration of such generation that connects through inverters, fault location and protection of microgrids needs consideration. This report proposes averaged models that help simulate fault scenarios in renewable-rich microgrids, models for locating faults in such microgrids, and comments on the protection models that may be considered for microgrids. Simulation studies are reported to justify the models.

  12. Planning Systems for Distributed Operations

    Science.gov (United States)

    Maxwell, Theresa G.

    2002-01-01

    This viewgraph representation presents an overview of the mission planning process involving distributed operations (such as the International Space Station (ISS)) and the computer hardware and software systems needed to support such an effort. Topics considered include: evolution of distributed planning systems, ISS distributed planning, the Payload Planning System (PPS), future developments in distributed planning systems, Request Oriented Scheduling Engine (ROSE) and Next Generation distributed planning systems.

  13. Photovoltaic system with improved AC connections and method of making same

    Energy Technology Data Exchange (ETDEWEB)

    Cioffi, Philip Michael; Todorovic, Maja Harfman; Herzog, Michael Scott; Korman, Charles Steven; Doherty, Donald M.; Johnson, Neil Anthony

    2018-02-13

    An alternating current (AC) harness for a photovoltaic (PV) system includes a wire assembly having a first end and a second end, the wire assembly having a plurality of lead wires, and at least one AC connection module positioned at a location along a length of the wire assembly between the first end and the second end. Further, the at least one AC connection module includes a first connection terminal electrically coupled to the plurality of lead wires of the wire assembly and constructed to electrically couple the wire assembly with an output of a first PV module of the PV system. The at least one AC connection module also includes a second connection terminal electrically coupled to the plurality of lead wires of the wire assembly and constructed to electrically couple the wire assembly with an output of a second PV module of the PV system.

  14. Robust Droop Control of Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Elkayam, Moria; Kuperman, Alon; Guerrero, Josep M.

    2016-01-01

    The use of distributed generation in microgrid systems is becoming a popular way to provide a reliable source of electricity to critical loads. Droop control techniques are used in power systems for the synchronization of grid-connected inverters by local measurements of active and reactive powers....... Despite the benefits of distributed generation, the drawback is that large grid-side impedance steps can cause a system to become unstable. A robust control method based on disturbance observer is proposed in this paper. When the proposed robust controller is utilized, closed loop performance remains...

  15. Frequency scanning-based stability analysis method for grid-connected inverter system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion with conside......This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion...... with consideration of the inverter nonlinearities. Small current disturbance is injected into grid-connected inverter system in a particular frequency range, and the impedance is computed according to the harmonic-frequency response using Fourier analysis, and then the stability is predicted on the basis...... of the impedance stability criterion. The stability issues of grid-connected inverters with grid-current feedback and the converter-current feedback are addressed using the proposed method. The results obtained from simulation and experiments validate the effectiveness of the method. The frequency scanning...

  16. Research on comprehensive decision-making of PV power station connecting system

    Science.gov (United States)

    Zhou, Erxiong; Xin, Chaoshan; Ma, Botao; Cheng, Kai

    2018-04-01

    In allusion to the incomplete indexes system and not making decision on the subjectivity and objectivity of PV power station connecting system, based on the combination of improved Analytic Hierarchy Process (AHP), Criteria Importance Through Intercriteria Correlation (CRITIC) as well as grey correlation degree analysis (GCDA) is comprehensively proposed to select the appropriate system connecting scheme of PV power station. Firstly, indexes of PV power station connecting system are divided the recursion order hierarchy and calculated subjective weight by the improved AHP. Then, CRITIC is adopted to determine the objective weight of each index through the comparison intensity and conflict between indexes. The last the improved GCDA is applied to screen the optimal scheme, so as to, from the subjective and objective angle, select the connecting system. Comprehensive decision of Xinjiang PV power station is conducted and reasonable analysis results are attained. The research results might provide scientific basis for investment decision.

  17. THE NEED OF CONNECTING THE TECHNOLOGY, POLITICAL AND CULTURAL SYSTEM

    Directory of Open Access Journals (Sweden)

    Marija Merdzhanovska

    2016-12-01

    Full Text Available The paper explores the need of connecting the technology, political and cultural system in the right way to achieve the companies’ goals in terms of globalization and changes. The leaders have the main role in realizing the company’s strategy. They must be strategy focused and they are responsible for connecting the employees, processes and technologies. In the beginning of the paper, the characteristics of strategy focused leadership are analyzed. The available tools of strategy focused leadership through the model are presented. The matrix of strategy management can be used like a manual which helps the management in connecting systems with managerial instruments: mission and strategy, organization structure and management of human resources. The goal of the paper is to show that with professional approach, the strategy focused leaders play the main role in connecting and changing the existing systems in companies. This is the way of reaching the best performance of companies and surviving at the global world market.

  18. World-wide distribution automation systems

    International Nuclear Information System (INIS)

    Devaney, T.M.

    1994-01-01

    A worldwide power distribution automation system is outlined. Distribution automation is defined and the status of utility automation is discussed. Other topics discussed include a distribution management system, substation feeder, and customer functions, potential benefits, automation costs, planning and engineering considerations, automation trends, databases, system operation, computer modeling of system, and distribution management systems

  19. Performance analysis for IEEE 802.11 distributed coordination function in radio-over-fiber-based distributed antenna systems.

    Science.gov (United States)

    Fan, Yuting; Li, Jianqiang; Xu, Kun; Chen, Hao; Lu, Xun; Dai, Yitang; Yin, Feifei; Ji, Yuefeng; Lin, Jintong

    2013-09-09

    In this paper, we analyze the performance of IEEE 802.11 distributed coordination function in simulcast radio-over-fiber-based distributed antenna systems (RoF-DASs) where multiple remote antenna units (RAUs) are connected to one wireless local-area network (WLAN) access point (AP) with different-length fiber links. We also present an analytical model to evaluate the throughput of the systems in the presence of both the inter-RAU hidden-node problem and fiber-length difference effect. In the model, the unequal delay induced by different fiber length is involved both in the backoff stage and in the calculation of Ts and Tc, which are the period of time when the channel is sensed busy due to a successful transmission or a collision. The throughput performances of WLAN-RoF-DAS in both basic access and request to send/clear to send (RTS/CTS) exchange modes are evaluated with the help of the derived model.

  20. High-Efficiency Photovoltaic System Using Partially-Connected DC-DC Converter

    Science.gov (United States)

    Uno, Masatoshi; Kukita, Akio; Tanaka, Koji

    Power conversion electronics for photovoltaic (PV) systems are desired to operate as efficiently as possible to exploit the power generated by PV modules. This paper proposes a novel PV system in which a dc-dc converter is partially connected to series-connected PV modules. The proposed system achieves high power-conversion efficiency by reducing the passing power and input/output voltages of the converter. The theoretical operating principle was experimentally validated. Resultant efficiency performances of the proposed and conventional systems demonstrated that the proposed system was more efficient in terms of power conversion though the identical converter was used for the both systems.

  1. A flocking algorithm for multi-agent systems with connectivity preservation under hybrid metric-topological interactions.

    Science.gov (United States)

    He, Chenlong; Feng, Zuren; Ren, Zhigang

    2018-01-01

    In this paper, we propose a connectivity-preserving flocking algorithm for multi-agent systems in which the neighbor set of each agent is determined by the hybrid metric-topological distance so that the interaction topology can be represented as the range-limited Delaunay graph, which combines the properties of the commonly used disk graph and Delaunay graph. As a result, the proposed flocking algorithm has the following advantages over the existing ones. First, range-limited Delaunay graph is sparser than the disk graph so that the information exchange among agents is reduced significantly. Second, some links irrelevant to the connectivity can be dynamically deleted during the evolution of the system. Thus, the proposed flocking algorithm is more flexible than existing algorithms, where links are not allowed to be disconnected once they are created. Finally, the multi-agent system spontaneously generates a regular quasi-lattice formation without imposing the constraint on the ratio of the sensing range of the agent to the desired distance between two adjacent agents. With the interaction topology induced by the hybrid distance, the proposed flocking algorithm can still be implemented in a distributed manner. We prove that the proposed flocking algorithm can steer the multi-agent system to a stable flocking motion, provided the initial interaction topology of multi-agent systems is connected and the hysteresis in link addition is smaller than a derived upper bound. The correctness and effectiveness of the proposed algorithm are verified by extensive numerical simulations, where the flocking algorithms based on the disk and Delaunay graph are compared.

  2. A flocking algorithm for multi-agent systems with connectivity preservation under hybrid metric-topological interactions.

    Directory of Open Access Journals (Sweden)

    Chenlong He

    Full Text Available In this paper, we propose a connectivity-preserving flocking algorithm for multi-agent systems in which the neighbor set of each agent is determined by the hybrid metric-topological distance so that the interaction topology can be represented as the range-limited Delaunay graph, which combines the properties of the commonly used disk graph and Delaunay graph. As a result, the proposed flocking algorithm has the following advantages over the existing ones. First, range-limited Delaunay graph is sparser than the disk graph so that the information exchange among agents is reduced significantly. Second, some links irrelevant to the connectivity can be dynamically deleted during the evolution of the system. Thus, the proposed flocking algorithm is more flexible than existing algorithms, where links are not allowed to be disconnected once they are created. Finally, the multi-agent system spontaneously generates a regular quasi-lattice formation without imposing the constraint on the ratio of the sensing range of the agent to the desired distance between two adjacent agents. With the interaction topology induced by the hybrid distance, the proposed flocking algorithm can still be implemented in a distributed manner. We prove that the proposed flocking algorithm can steer the multi-agent system to a stable flocking motion, provided the initial interaction topology of multi-agent systems is connected and the hysteresis in link addition is smaller than a derived upper bound. The correctness and effectiveness of the proposed algorithm are verified by extensive numerical simulations, where the flocking algorithms based on the disk and Delaunay graph are compared.

  3. Distributed Operating Systems

    NARCIS (Netherlands)

    Mullender, Sape J.

    1987-01-01

    In the past five years, distributed operating systems research has gone through a consolidation phase. On a large number of design issues there is now considerable consensus between different research groups. In this paper, an overview of recent research in distributed systems is given. In turn, the

  4. Distributed Online Learning in Social Recommender Systems

    Science.gov (United States)

    Tekin, Cem; Zhang, Simpson; van der Schaar, Mihaela

    2014-08-01

    In this paper, we consider decentralized sequential decision making in distributed online recommender systems, where items are recommended to users based on their search query as well as their specific background including history of bought items, gender and age, all of which comprise the context information of the user. In contrast to centralized recommender systems, in which there is a single centralized seller who has access to the complete inventory of items as well as the complete record of sales and user information, in decentralized recommender systems each seller/learner only has access to the inventory of items and user information for its own products and not the products and user information of other sellers, but can get commission if it sells an item of another seller. Therefore the sellers must distributedly find out for an incoming user which items to recommend (from the set of own items or items of another seller), in order to maximize the revenue from own sales and commissions. We formulate this problem as a cooperative contextual bandit problem, analytically bound the performance of the sellers compared to the best recommendation strategy given the complete realization of user arrivals and the inventory of items, as well as the context-dependent purchase probabilities of each item, and verify our results via numerical examples on a distributed data set adapted based on Amazon data. We evaluate the dependence of the performance of a seller on the inventory of items the seller has, the number of connections it has with the other sellers, and the commissions which the seller gets by selling items of other sellers to its users.

  5. Performance Parameters for Grid-Connected PV Systems

    Energy Technology Data Exchange (ETDEWEB)

    Marion, B.; Adelstein, J.; Boyle, K.; Hayden, H.; Hammond, B.; Fletcher, T.; Canada, B.; Narang, D.; Shugar, D.; Wenger, H.; Kimber, A.; Mitchell, L.; Rich, G.; Townsend, T.

    2005-02-01

    The use of appropriate performance parameters facilitates the comparison of grid-connected photovoltaic (PV) systems that may differ with respect to design, technology, or geographic location. Four performance parameters that define the overall system performance with respect to the energy production, solar resource, and overall effect of system losses are the following: final PV system yield, reference yield, performance ratio, and PVUSA rating. These performance parameters are discussed for their suitability in providing desired information for PV system design and performance evaluation and are demonstrated for a variety of technologies, designs, and geographic locations. Also discussed are methodologies for determining system a.c. power ratings in the design phase using multipliers developed from measured performance parameters.The use of appropriate performance parameters facilitates the comparison of grid-connected photovoltaic (PV) systems that may differ with respect to design, technology, or geographic location. Four performance parameters that define the overall system performance with respect to the energy production, solar resource, and overall effect of system losses are the following: final PV system yield, reference yield, performance ratio, and PVUSA rating. These performance parameters are discussed for their suitability in providing desired information for PV system design and performance evaluation and are demonstrated for a variety of technologies, designs, and geographic locations. Also discussed are methodologies for determining system a.c. power ratings in the design phase using multipliers developed from measured performance parameters.

  6. The Simulation Study of a Restructured Residential Low-Voltage Distribution System Microgrid

    Directory of Open Access Journals (Sweden)

    L. Ramesh

    2016-12-01

    Full Text Available A primary and necessary focus in creating a greener environment is the conversion of existing power-generation sources to renewable power sources in the near future. Another important focus is to develop sustainable household power generation to a low-voltage electricity grid with a power purchase and selling facility. To help with achieving the above vision, the objective of this work is to critically analyze the existing low-voltage distribution system and make suggestions for restructuring it to the low-voltage interconnected microgrid (MG. The test was carried out in the Tamil Nadu Electricity Board (TNEB 100kVA transformer feeder which was connected to supply around 100 houses with electricity. The performance analysis of the proposed system was examined through different case studies, represented as a normal operating condition of the existing distribution system and a reconstructed and interconnected MG to the TNEB grid. The project was designed and analyzed using PSCAD software. The results discussed in the project are helpful in examining the effects of multiple distributed energy resources on distributed generation. In future, knowledge of these effects may be helpful for rural area electrification.

  7. Pervasive Electricity Distribution System

    Directory of Open Access Journals (Sweden)

    Muhammad Usman Tahir

    2017-06-01

    Full Text Available Now a days a country cannot become economically strong until and unless it has enough electrical power to fulfil industrial and domestic needs. Electrical power being the pillar of any country’s economy, needs to be used in an efficient way. The same step is taken here by proposing a new system for energy distribution from substation to consumer houses, also it monitors the consumer consumption and record data. Unlike traditional manual Electrical systems, pervasive electricity distribution system (PEDS introduces a fresh perspective to monitor the feeder line status at distribution and consumer level. In this system an effort is taken to address the issues of electricity theft, manual billing, online monitoring of electrical distribution system and automatic control of electrical distribution points. The project is designed using microcontroller and different sensors, its GUI is designed in Labview software.

  8. Economic Power Dispatch of Distributed Generators in a Grid-Connected Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Andrade, Fabio

    2015-01-01

    Grid-connected microgrids with storage systems are reliable configurations for critical loads which can not tolerate interruptions of energy supply. In such cases, some of the energy resources should be scheduled in order to coordinate optimally the power generation according to a defined objective...

  9. Task 5. Grid interconnection of building integrated and other dispersed photovoltaic power systems. International guideline for the certification of photovoltaic system components and grid-connected systems

    Energy Technology Data Exchange (ETDEWEB)

    Bower, W.

    2002-02-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme presents a guideline for the certification of photovoltaic system components and grid-connected systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This generic international guideline for the certification of photovoltaic system components and complete grid-connected photovoltaic systems describes a set of recommended methods and tests that may be used to verify the integrity of hardware and installations, compliance with applicable standards/codes and can be used to provide a measure of the performance of components or of entire systems. The guideline is to help ensure that photovoltaic installations are both safe for equipment as well as for personnel when used according to the applicable installation standards and codes. The guideline may be used in any country using the rules stipulated by the applicable standards and codes and by applying them to the guideline's recommended tests. This document uses examples for some tests but does not specify exact test set-ups, equipment accuracy, equipment manufacturers or calibration procedures.

  10. Grid-Connected Photovoltaic System with Active Power Filtering Functionality

    Directory of Open Access Journals (Sweden)

    Joaquín Vaquero

    2018-01-01

    Full Text Available Solar panels are an attractive and growing source of renewable energy in commercial and residential applications. Its use connected to the grid by means of a power converter results in a grid-connected photovoltaic system. In order to optimize this system, it is interesting to integrate several functionalities into the power converter, such as active power filtering and power factor correction. Nonlinear loads connected to the grid generate current harmonics, which deteriorates the mains power quality. Active power filters can compensate these current harmonics. A photovoltaic system with added harmonic compensation and power factor correction capabilities is proposed in this paper. A sliding mode controller is employed to control the power converter, implemented on the CompactRIO digital platform from National Instruments Corporation, allowing user friendly operation and easy tuning. The power system consists of two stages, a DC/DC boost converter and a single-phase inverter, and it is able to inject active power into the grid while compensating the current harmonics generated by nonlinear loads at the point of common coupling. The operation, design, simulation, and experimental results for the proposed system are discussed.

  11. Overview of Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    A still booming installation of solar photovoltaic (PV) systems has been witnessed worldwide. It is mainly driven by the demand of “clean” power generation. Grid-connected PV systems will become an even active player in the future mixed power systems, which are linked by a vast of power electronics...

  12. Grid-connected inverter for wind power generation system

    Institute of Scientific and Technical Information of China (English)

    YANG Yong; RUAN Yi; SHEN Huan-qing; TANG Yan-yan; YANG Ying

    2009-01-01

    In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on PI-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.

  13. Microgrids and distributed generation systems: Control, operation, coordination and planning

    Science.gov (United States)

    Che, Liang

    Distributed Energy Resources (DERs) which include distributed generations (DGs), distributed energy storage systems, and adjustable loads are key components in microgrid operations. A microgrid is a small electric power system integrated with on-site DERs to serve all or some portion of the local load and connected to the utility grid through the point of common coupling (PCC). Microgrids can operate in both grid-connected mode and island mode. The structure and components of hierarchical control for a microgrid at Illinois Institute of Technology (IIT) are discussed and analyzed. Case studies would address the reliable and economic operation of IIT microgrid. The simulation results of IIT microgrid operation demonstrate that the hierarchical control and the coordination strategy of distributed energy resources (DERs) is an effective way of optimizing the economic operation and the reliability of microgrids. The benefits and challenges of DC microgrids are addressed with a DC model for the IIT microgrid. We presented the hierarchical control strategy including the primary, secondary, and tertiary controls for economic operation and the resilience of a DC microgrid. The simulation results verify that the proposed coordinated strategy is an effective way of ensuring the resilient response of DC microgrids to emergencies and optimizing their economic operation at steady state. The concept and prototype of a community microgrid that interconnecting multiple microgrids in a community are proposed. Two works are conducted. For the coordination, novel three-level hierarchical coordination strategy to coordinate the optimal power exchanges among neighboring microgrids is proposed. For the planning, a multi-microgrid interconnection planning framework using probabilistic minimal cut-set (MCS) based iterative methodology is proposed for enhancing the economic, resilience, and reliability signals in multi-microgrid operations. The implementation of high-reliability microgrids

  14. Hybrid Control System for Greater Resilience Using Multiple Isolation and Building Connection

    Directory of Open Access Journals (Sweden)

    Masaki Taniguchi

    2016-10-01

    Full Text Available An innovative hybrid control building system of multiple isolation and connection is proposed and investigated using both time-history and input energy responses for various types of ground motions together with transfer functions. It is concerned that the seismic displacement response at the base-isolation layer of the existing base-isolated buildings may extremely increase under long-period and long-duration ground motions which are getting great attention recently. In order to enhance the seismic performance of those base-isolated buildings, a novel hybrid system of multiple isolation and building-connection is proposed and compared with other structural systems such as an independent multiple isolation system, a hybrid system of base-isolation and building-connection. Furthermore, the robustness of seismic responses of the proposed hybrid system for various types of ground motion is discussed through the comparison of various structural systems including non-hybrid systems. Finally the optimal connection damper location is investigated using a sensitivity-type optimization approach.

  15. Hybrid system power generation'wind-photovoltaic' connected to the ...

    African Journals Online (AJOL)

    Hybrid system power generation'wind-photovoltaic' connected to the ... from Hybrid System, power delivered to or from grid and phase voltage of the inverter leg. ... Renewable Energy, Electrical Network 220 kV, Hybrid System, Solar, MPPT.

  16. Power take-off analysis for diagonally connected MHD channels

    International Nuclear Information System (INIS)

    Pan, Y.C.; Doss, E.D.

    1980-01-01

    The electrical loading of the power take-off region of diagonally connected MHD channels is investigated by a two-dimensional model. The study examines the loading schemes typical of those proposed for the U-25 and U-25 Bypass channels. The model is applicable for the following four cases: (1) connection with diodes only, (2) connection with diodes and equal resistors, (3) connection with diodes and variable resistances to obtain a given current distribution, and (4) connection with diodes and variable resistors under changing load. The analysis is applicable for the power take-off regions of single or multiple-output systems. The general behaviors of the current and the potential distributions in all four cases are discussed. The analytical results are in good agreement with the experimental data. It is found possible to design the electrical circuit of the channel in the take-off region so as to achieve a fairly even load current output under changing total load current

  17. Evaluation of a Connectionless NoC for a Real-Time Distributed Shared Memory Many-Core System

    NARCIS (Netherlands)

    Rutgers, J.H.; Bekooij, Marco Jan Gerrit; Smit, Gerardus Johannes Maria

    2012-01-01

    Real-time embedded systems like smartphones tend to comprise an ever increasing number of processing cores. For scalability and the need for guaranteed performance, the use of a connection-oriented network-on-chip (NoC) is advocated. Furthermore, a distributed shared memory architecture is preferred

  18. A system design for distributed energy generation in low temperature district heating (LTDH) networks

    OpenAIRE

    Jones, Sean; Gillott, Mark C.; Boukhanouf, Rabah; Walker, Gavin S.; Tunzi, Michele; Tetlow, David; Rodrigues, Lucélia Taranto; Sumner, M.

    2017-01-01

    Project SCENIC (Smart Controlled Energy Networks Integrated in Communities) involves connecting properties at the University of Nottingham’s Creative Energy Homes test site in a community scale, integrated heat and power network. Controls will be developed to allow for the most effective heat load allocation and power distribution scenarios. Furthermore, the system will develop the prosumer concept, where consumers are both buyers and sellers of energy in both heat and power systems. \\ud \\ud ...

  19. Power system reconfiguration in a radial distribution network for reducing losses and to improve voltage profile using modified plant growth simulation algorithm with Distributed Generation (DG

    Directory of Open Access Journals (Sweden)

    R. Rajaram

    2015-11-01

    Full Text Available Network reconfiguration which is constrained non linear optimization problem has been solved for loss minimization, load balancing, etc. for last two decades using various heuristic search evolutionary algorithms like binary particle swarm optimization, neuro-fuzzy techniques, etc. The contribution of this paper lies in considering distributed generation which are smaller power sources like solar photovoltaic cells or wind turbines connected in the customer roof top. This new connection in the radial network has made unidirectional current flow to become bidirectional there by increasing the efficiency but sometimes reducing stability of the system. Modified plant growth simulation algorithm has been applied here successfully to minimize real power loss because it does not require barrier factors or cross over rates because the objectives and constraints are dealt separately. The main advantage of this algorithm is continuous guiding search along with changing objective function because power from distributed generation is continuously varying so this can be applied for real time applications with required modifications. This algorithm here is tested for a standard 33 bus radial distribution system for loss minimization and test results here shows that this algorithm is efficient and suitable for real time applications.

  20. Optimizing queries in distributed systems

    Directory of Open Access Journals (Sweden)

    Ion LUNGU

    2006-01-01

    Full Text Available This research presents the main elements of query optimizations in distributed systems. First, data architecture according with system level architecture in a distributed environment is presented. Then the architecture of a distributed database management system (DDBMS is described on conceptual level followed by the presentation of the distributed query execution steps on these information systems. The research ends with presentation of some aspects of distributed database query optimization and strategies used for that.

  1. Design of Two Feeder Three Phase Four Wire Distribution System Utilizing Multi Converter UPQC with Fuzzy Logic Controller

    Directory of Open Access Journals (Sweden)

    Chandra Babu Paduchuri

    2014-01-01

    Full Text Available This paper proposes the instantaneous p-q theory based fuzzy logic controller (FLC for multi converter unified power quality conditioner (MC-UPQC to mitigate power quality issues in two feeders three-phase four-wire distribution systems. The proposed system is extended system of the existing one feeder three-phase four-wire distribution system, which is operated with UPQC. This system is employed with three voltage source converters, which are connected commonly to two feeder distribution systems. The performance of this proposed system used to compensate voltage sag, neutral current mitigation and compensation of voltage and current harmonics under linear and nonlinear load conditions. The neutral current flowing in series transformers is zero in the implementation of the proposed system. The simulation performance analysis is carried out using MATLAB.

  2. Guidelines for Implementing Advanced Distribution Management Systems-Requirements for DMS Integration with DERMS and Microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States); Chen, Chen [Argonne National Lab. (ANL), Argonne, IL (United States); Lu, Xiaonan [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-08-01

    This guideline focuses on the integration of DMS with DERMS and microgrids connected to the distribution grid by defining generic and fundamental design and implementation principles and strategies. It starts by addressing the current status, objectives, and core functionalities of each system, and then discusses the new challenges and the common principles of DMS design and implementation for integration with DERMS and microgrids to realize enhanced grid operation reliability and quality power delivery to consumers while also achieving the maximum energy economics from the DER and microgrid connections.

  3. The COSY control system, a distributed realtime operating system: First practical experience at the COSY-injector

    International Nuclear Information System (INIS)

    Stephan, M.; Hacker, U.; Henn, K.; Richert, A.; Sobotta, K.; Weinert, A.

    1991-01-01

    The COSY control system is hierarchically organized with distributed intelligence and autonomous processing units for dedicated components. Data communication is performed via LAN and over a fieldbus. The hostsystems are UNIX-based, whereas the field-controllers are running a modular realtime operating-system RT/OS which has been developed at KFA. The computer-hardware consists of RISC mini computers, VME-computers in the field and G64 equipment-control-module in geographical expansion of the controller by a fieldbus based on the PDV-standard. The man-machine interface consists of X-window based work stations. On top of X-window a graphical user interface based on object oriented methods is used. A distributed realtime data base allows access to the accelerator state from every workstation. A special highlevel language debugger hosted on the UNIX based workstation and connected over LAN to the VME targets will be used. Together with the software development system for UNIX applications an uniform view of the system appears to the programmer. First practical experience at the COSY injector is presented

  4. Distributed fiber optic moisture intrusion sensing system

    Science.gov (United States)

    Weiss, Jonathan D.

    2003-06-24

    Method and system for monitoring and identifying moisture intrusion in soil such as is contained in landfills housing radioactive and/or hazardous waste. The invention utilizes the principle that moist or wet soil has a higher thermal conductance than dry soil. The invention employs optical time delay reflectometry in connection with a distributed temperature sensing system together with heating means in order to identify discrete areas within a volume of soil wherein temperature is lower. According to the invention an optical element and, optionally, a heating element may be included in a cable or other similar structure and arranged in a serpentine fashion within a volume of soil to achieve efficient temperature detection across a large area or three dimensional volume of soil. Remediation, moisture countermeasures, or other responsive action may then be coordinated based on the assumption that cooler regions within a soil volume may signal moisture intrusion where those regions are located.

  5. A novel single-phase phase space-based voltage mode controller for distributed static compensator to improve voltage profile of distribution systems

    International Nuclear Information System (INIS)

    Shokri, Abdollah; Shareef, Hussain; Mohamed, Azah; Farhoodnea, Masoud; Zayandehroodi, Hadi

    2014-01-01

    Highlights: • A new phase space based voltage mode controller for D-STATCOM was proposed. • The proposed compensator was tested to mitigate voltage disturbances in distribution systems. • Voltage fluctuation, voltage sag and voltage swell are considered to evaluate the performance of the proposed compensator. - Abstract: Distribution static synchronous compensator (D-STATCOM) has been developed and attained a great interest to compensate the power quality disturbances of distribution systems. In this paper, a novel single-phase control scheme for D-STATCOM is proposed to improve voltage profile at the Point of Common Coupling (PCC). The proposed voltage mode (VM) controller is based on the phase space algorithm, which is able to rapidly detect and mitigate any voltage deviations from reference voltage including voltage sags and voltage swells. To investigate the efficiency and accuracy of the proposed compensator, a system is modeled using Matlab/Simulink. The simulation results approve the capability of the proposed VM controller to provide a regulated and disturbance-free voltage for the connected loads at the PCC

  6. Energy Management of Smart Distribution Systems

    Science.gov (United States)

    Ansari, Bananeh

    Electric power distribution systems interface the end-users of electricity with the power grid. Traditional distribution systems are operated in a centralized fashion with the distribution system owner or operator being the only decision maker. The management and control architecture of distribution systems needs to gradually transform to accommodate the emerging smart grid technologies, distributed energy resources, and active electricity end-users or prosumers. The content of this document concerns with developing multi-task multi-objective energy management schemes for: 1) commercial/large residential prosumers, and 2) distribution system operator of a smart distribution system. The first part of this document describes a method of distributed energy management of multiple commercial/ large residential prosumers. These prosumers not only consume electricity, but also generate electricity using their roof-top solar photovoltaics systems. When photovoltaics generation is larger than local consumption, excess electricity will be fed into the distribution system, creating a voltage rise along the feeder. Distribution system operator cannot tolerate a significant voltage rise. ES can help the prosumers manage their electricity exchanges with the distribution system such that minimal voltage fluctuation occurs. The proposed distributed energy management scheme sizes and schedules each prosumer's ES to reduce the electricity bill and mitigate voltage rise along the feeder. The second part of this document focuses on emergency energy management and resilience assessment of a distribution system. The developed emergency energy management system uses available resources and redundancy to restore the distribution system's functionality fully or partially. The success of the restoration maneuver depends on how resilient the distribution system is. Engineering resilience terminology is used to evaluate the resilience of distribution system. The proposed emergency energy

  7. Review international standards for grid connected photovoltaic systems in Malaysia

    International Nuclear Information System (INIS)

    Mekhilef, S.; Rahim, N.A.

    2006-01-01

    Grid connected PV is being applied on variety application including large centralised stations, commercial building and individual houses. There is a need for specific standard to address distinctive new issue created by grid connected PV power system. Internationally many countries are attempting to develop standards for building integration, Dc side issues and grid connection issues. This paper surveys the current development state of the major countries standards in this area, comparing and contrasting, standards and guideline under development, also addressing the need of standards for grid connected in Malaysia

  8. Radiological approach to systemic connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, W; Schneider, M

    1988-07-01

    Systemic lupus erythematosus (SLE) and progressive systemic sclerosis (PSS) represent the most frequent manifestations of systemic connective tissue diseases (collagen diseases). Radiological examinations are employed to estimate the extension and degree of the pathological process. In addition, progression of the disease can be verified. In both of the above collagen diseases, specific radiological findings can be observed that permit them to be differentiated from other entities. An algorithm for the adequate radiological work-up of collagen diseases is presented.

  9. Network integration of distributed generation: international research and development

    Energy Technology Data Exchange (ETDEWEB)

    Watson, J.

    2003-07-01

    This report provides information on privately and publicly funded research and development programmes in distributed generation (DG) in the USA, the European Union and Japan. Protection systems for the installation of DG, power electronics for the connection of DG to electricity distribution systems, reliability modelling, power quality issues, connection standards, and simulation and computer modelling are examined. The relevance of the programmes to the UK is considered.

  10. The impact of photovoltaic systems on distribution transformer: A case study

    International Nuclear Information System (INIS)

    Jimenez, Humberto; Calleja, Hugo; Gonzalez, Raul; Huacuz, Jorge; Lagunas, Javier

    2006-01-01

    In this paper, the results obtained after monitoring a distribution transformer during an 18 months period are described and discussed. The transformer fed several households, each with a grid connected photovoltaic system, and it was found that the power factor at the transformer attained unusually low levels. This was due to the fact that under some conditions, the systems provided a large portion of the active power demanded by the households, while the grid supplied all the reactive and distortion powers. The operating temperature was used as an indicator of the stress on the transformer. The temperature was at its lowest when the systems were providing the maximum energy available from the solar cells

  11. Macaque accessory optic system: II. Connections with the pretectum

    International Nuclear Information System (INIS)

    Baleydier, C.; Magnin, M.; Cooper, H.M.

    1990-01-01

    Connections of the accessory optic system (AOS) with the pretectum are described in the macaque monkey. Injections of tritiated amino acids in the pretectum demonstrate a major contralateral projection to the dorsal (DTN), lateral (LTN), and medial (MTN) terminal nuclei of the AOS and a sparser projection to the ipsilateral LTN. Injections of retrograde tracers, Fast Blue (FB), or wheat germ agglutinin horseradish peroxidase (WGA-HRP) plus nonconjugated horseradish peroxidase (HRP) in the LTN show that the pretectal-LTN projection originates from two nuclei. The main source of pretectal efferents to the LTN is from the pretectal olivary nucleus (OPN) and is entirely contralateral. This projection, which appears unique to primates, originates from the large multipolar cells of the OPN. In addition to this projection, the nucleus of the optic tract (NOT) projects to the ipsilateral LTN, as in nonprimates. Injection of WGA-HRP in the pretectum shows a reciprocal predominantely ipsilateral projection from the LTN to the pretectum. Retinas were observed after injection of FB in the LTN. The retinal ganglion cells projecting to the AOS are mainly distributed near the fovea and in the nasal region of the contralateral eye, suggesting a nasotemporal pattern of decussation. The demonstration of a direct connection between LTN and OPN forces to a reconsideration of the functional role of the AOS. Previous descriptions of luminance responsive cells in the LTN support a possible participation of this nucleus in the control of the pupillary light reflex

  12. Thermal Distribution System | Energy Systems Integration Facility | NREL

    Science.gov (United States)

    Thermal Distribution System Thermal Distribution System The Energy Systems Integration Facility's . Photo of the roof of the Energy Systems Integration Facility. The thermal distribution bus allows low as 10% of its full load level). The 60-ton chiller cools water with continuous thermal control

  13. Photovoltaic system connected to electric grid in Brazil; Sistemas fotovoltaicos conectados a rede eletrica no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Varella, Fabiana Karla de Oliveira Martins [Universidade Federal Rural do Semi-Arido (UFERSA), Mossoro, RN (Brazil)], email: fkv@ufersa.edu.br; Gomes, Rodolfo Dourado Maia; Jannuzzi, Gilberto De Martino [International Energy Initiative (IEI), Campinas, SP (Brazil)], email: rodolfo@iei-la.org

    2010-07-01

    Brazil has in the next decades the big challenge of seeking for solutions to meet its growing energy service needs and, at the same time, satisfy criteria of economics, security of supply, public health, secure universal energy access and environmental sustainability. The growing environmental pressures over the hydropower potential exploitation at the Amazon region and the energy sources even more distant from the customer load center are some of the aspects which are posed in order to seek for solutions. Several countries are betting on grid-connected PV systems. In Brazil, the initiatives to promote the use of PV energy are still a few. Even though the country is endowed with a great solar energy potential, the initiatives to create and consolidate a market for the use of such technology and to develop the national industry for equipment and services are still incipient. The lack of legislation and regulation is one of the barriers pointed out. Thus, the objective of this report is to assess the reasons why the country does not have a specific legislation to promote the use of grid-connected PV systems. For such, grid-connected PV systems installed in Brazil and the existent incentives are identified. The methodology used was based on literature review and conduction of specific questionnaires. The latter was sent to the Ministry of Mines and Energy, researchers and one power distribution company. (author)

  14. Solar System Connections to the Organic Material In the ISM

    Science.gov (United States)

    Pendleton, Yvonne J.

    2003-01-01

    The organic component of the interstellar medium (ISM) has relevance to the formation of the early solar nebula, since our solar system formed out of ISM material. Comparisons of near infrared spectra of the diffuse ISM dust with those of primitive solar system bodies (such as comets and meteorites) show a remarkable similarity, suggesting that perhaps some of the interstellar organic material made its way, unaltered, into our solar system. Tracing the interstellar organic material is necessary to understand how these materials may be important links in the development of prebiotic phenomena. Studies of the ISM reveal that the organic refractory component of the diffuse ISM is largely hydrocarbon in nature, possessing little N or O, with carbon distributed between the aromatic and aliphatic forms. There is a strong similarity in the near IR spectra of the diffuse ISM (the 3.4 micron hydrocarbon bands) and those seen in the Murchison and Orgueil meteorites, however, detailed comparisons at longer wavelengths reveal critical dissimilarities. Here we will present comparisons and discussion of relevant spectra. As we continue to explore, we will gain insight into the connection between planetesimals in the solar system and chemistry in the dusty space between the stars.

  15. Sectional pipeline bundles. Design, fabrication and testing of a subsea pipeline connection system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    The tests of the prototype system indicated that the system is applicable for connecting pipeline bundle sections. The overall performance of the system is therefore concluded to be satisfactory. Some modifications are required though, for improving the reliability of the system to the level required for offshore North Sea application. The tests showed that connection of the pipeline bundle sections can be performed for alignment tolerances larger than those expected during a typical subsea installation. Pull-in of bundle end sections can be performed with pull-in wires deployed from surface. The offshore tests showed that handling of wires must be done with great care to avoid possibility for wire entanglement, especially if a fully diverless system is to be used. The flowline connection tool was found to be suitable for final alignment of the individual spool ends. It was demonstrated that face to face contact between the hub faces in the connector was obtained after tie-in. Pressure tests showed that the connector could be sealed by the tie-in force applied by the connection tool tie-in system. However, the standard connector clamp which was used, was found to be insuficient for maintaining the connector effectively sealed after removal of the pull-in force applied by the connection tool. Based on the results proposals for improvements of the system are included. Improvements are applicable to the current system for connection of bundle sections or for tie-in operations, relating to conventional pipelines. The improvements also includes a strong connection clamp suitable for subsea use. The connection clamp will replace the standard clamp devise used in this project. (au) EFP-96. 41 refs.

  16. Connected Lighting Systems Efficiency Study$-$ PoE Cable Energy Losses, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Tuenge, Jason [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kelly, Karsten [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poplawski, Michael [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-11-30

    First report in a study of the efficiency of connected lighting systems. The report summarizes the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines recently introduced by the American National Standards Institute (ANSI) C137 Lighting Systems Committee.

  17. A New Wind Turbine Generating System Model for Balanced and Unbalanced Distribution Systems Load Flow Analysis

    Directory of Open Access Journals (Sweden)

    Ahmet Koksoy

    2018-03-01

    Full Text Available Wind turbine generating systems (WTGSs, which are conventionally connected to high voltage transmission networks, have frequently been employed as distributed generation units in today’s distribution networks. In practice, the distribution networks always have unbalanced bus voltages and line currents due to uneven distribution of single or double phase loads over three phases and asymmetry of the lines, etc. Accordingly, in this study, for the load flow analysis of the distribution networks, Conventional Fixed speed Induction Generator (CFIG based WTGS, one of the most widely used WTGS types, is modelled under unbalanced voltage conditions. The Developed model has active and reactive power expressions in terms of induction machine impedance parameters, terminal voltages and input power. The validity of the Developed model is confirmed with the experimental results obtained in a test system. The results of the slip calculation based phase-domain model (SCP Model, which was previously proposed in the literature for CFIG based WTGSs under unbalanced voltages, are also given for the comparison. Finally, the Developed model and the SCP model are implemented in the load flow analysis of the IEEE 34 bus test system with the CFIG based WTGSs and unbalanced loads. Thus, it is clearly pointed out that the results of the load flow analysis implemented with both models are very close to each other, and the Developed model is computationally more efficient than the SCP model.

  18. Syntactic processing is distributed across the language system.

    Science.gov (United States)

    Blank, Idan; Balewski, Zuzanna; Mahowald, Kyle; Fedorenko, Evelina

    2016-02-15

    Language comprehension recruits an extended set of regions in the human brain. Is syntactic processing localized to a particular region or regions within this system, or is it distributed across the entire ensemble of brain regions that support high-level linguistic processing? Evidence from aphasic patients is more consistent with the latter possibility: damage to many different language regions and to white-matter tracts connecting them has been shown to lead to similar syntactic comprehension deficits. However, brain imaging investigations of syntactic processing continue to focus on particular regions within the language system, often parts of Broca's area and regions in the posterior temporal cortex. We hypothesized that, whereas the entire language system is in fact sensitive to syntactic complexity, the effects in some regions may be difficult to detect because of the overall lower response to language stimuli. Using an individual-subjects approach to localizing the language system, shown in prior work to be more sensitive than traditional group analyses, we indeed find responses to syntactic complexity throughout this system, consistent with the findings from the neuropsychological patient literature. We speculate that such distributed nature of syntactic processing could perhaps imply that syntax is inseparable from other aspects of language comprehension (e.g., lexico-semantic processing), in line with current linguistic and psycholinguistic theories and evidence. Neuroimaging investigations of syntactic processing thus need to expand their scope to include the entire system of high-level language processing regions in order to fully understand how syntax is instantiated in the human brain. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Experimental grid connected PV system power analysis

    Science.gov (United States)

    Semaoui, Smail; Abdeladim, Kamel; Arab, Amar Hadj; Boulahchich, Saliha; Amrouche, Said Ould; Yassaa, Noureddine

    2018-05-01

    Almost 80 % of Algerian territory is appropriate for the exploitation of solar energy. The Algerian energetic strategy provides a substantial injection of PV electricity to the national grid. Currently, about 344 MWp of PV arrays which corresponds approximately to 2,34 km2 of module surfaces, are connected on electricity grid over the national territory. The Algerian Northern regions are characterized by strong pollution and high humidity. These phenomena affect the energetic productivity of PV generator. The objective of our study is to analyze experimental grid connected PV system power in coastal locations. Hence, experiments have been conducted on three identical PV systems to determine the electrical performances. Transformer-less inverters are the most attractive for the ground-based photovoltaic (PV) system due to their efficiencies, reduced cost and weight. Besides, the absence of the galvanic isolation generates problems of capacitive leakage current on the AC side and the degradation of the insulation resistance on the DC side of the inverter. In this work, experimental study of the behavior of single-phase inverters without transformers is presented. The main objective of this work is to study the degradation of the insulation resistance at the input of the inverter, and the capacitive leakage current at the output of the inverter. This study was achieved at the CDER on a rainy day of 15/03/2017, on the first PV plant connected to the low voltage network in Algeria. This investigation can help forecasting the PV array energetic production by taking into account natural conditions.

  20. Radiological approach to systemic connective tissue diseases

    International Nuclear Information System (INIS)

    Wiesmann, W.; Schneider, M.

    1988-01-01

    Systemic lupus erythematosus (SLE) and progressive systemic sclerosis (PSS) represent the most frequent manifestations of systemic connective tissue diseases (collagen diseases). Radiological examinations are employed to estimate the extension and degree of the pathological process. In addition, progression of the disease can be verified. In both of the above collagen diseases, specific radiological findings can be observed that permit them to be differentiated from other entities. An algorithm for the adequate radiological work-up of collagen diseases is presented. (orig.) [de

  1. Distributed patterns of occipito-parietal functional connectivity predict the precision of visual working memory.

    Science.gov (United States)

    Galeano Weber, Elena M; Hahn, Tim; Hilger, Kirsten; Fiebach, Christian J

    2017-02-01

    Limitations in visual working memory (WM) quality (i.e., WM precision) may depend on perceptual and attentional limitations during stimulus encoding, thereby affecting WM capacity. WM encoding relies on the interaction between sensory processing systems and fronto-parietal 'control' regions, and differences in the quality of this interaction are a plausible source of individual differences in WM capacity. Accordingly, we hypothesized that the coupling between perceptual and attentional systems affects the quality of WM encoding. We combined fMRI connectivity analysis with behavioral modeling by fitting a variable precision and fixed capacity model to the performance data obtained while participants performed a visual delayed continuous response WM task. We quantified functional connectivity during WM encoding between occipital and parietal brain regions activated during both perception and WM encoding, as determined using a conjunction of two independent experiments. The multivariate pattern of voxel-wise inter-areal functional connectivity significantly predicted WM performance, most specifically the mean of WM precision but not the individual number of items that could be stored in memory. In particular, higher occipito-parietal connectivity was associated with higher behavioral mean precision. These results are consistent with a network perspective of WM capacity, suggesting that the efficiency of information flow between perceptual and attentional neural systems is a critical determinant of limitations in WM quality. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Proceedings: Distributed digital systems, plant process computers, and networks

    International Nuclear Information System (INIS)

    1995-03-01

    These are the proceedings of a workshop on Distributed Digital Systems, Plant Process Computers, and Networks held in Charlotte, North Carolina on August 16--18, 1994. The purpose of the workshop was to provide a forum for technology transfer, technical information exchange, and education. The workshop was attended by more than 100 representatives of electric utilities, equipment manufacturers, engineering service organizations, and government agencies. The workshop consisted of three days of presentations, exhibitions, a panel discussion and attendee interactions. Original plant process computers at the nuclear power plants are becoming obsolete resulting in increasing difficulties in their effectiveness to support plant operations and maintenance. Some utilities have already replaced their plant process computers by more powerful modern computers while many other utilities intend to replace their aging plant process computers in the future. Information on recent and planned implementations are presented. Choosing an appropriate communications and computing network architecture facilitates integrating new systems and provides functional modularity for both hardware and software. Control room improvements such as CRT-based distributed monitoring and control, as well as digital decision and diagnostic aids, can improve plant operations. Commercially available digital products connected to the plant communications system are now readily available to provide distributed processing where needed. Plant operations, maintenance activities, and engineering analyses can be supported in a cost-effective manner. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  3. System performance of a three-phase PV-grid-connected system installed in Thailand. Data monitored analysis

    International Nuclear Information System (INIS)

    Boonmee, Chaiyant; Watjanatepin, Napat; Plangklang, Boonyang

    2009-01-01

    PV-grid-connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid and to feed the surplus energy back into the grid. The system needs no battery so therefore the system price is very cheap comparing to other PV systems. PV-grid-connected systems are used in buildings that already hooked up to the electrical grid. Finding efficiency of the PV-grid-connected system can be done by using a standard instrument which needs to disconnect the PV arrays from the grid before measurement. The measurement is also difficult and we lose energy during the measurement. This paper will present the system performance of a PV-grid-connected system installed in Thailand by using a monitoring system. The monitored data are installed by acquisition software into a computer. Analysis of monitored data will be done to find out the system performance without disconnecting the PV arrays from the system. The monitored data include solar radiation, PV voltage, PV current, and PV power which has been recorded from a 5 kWp system installed of amorphous silicon PV at Rajamangala University of Technology Suvarnabhumi, Nonthaburi, Thailand. The system performance of the system by using the data monitored is compared to the standard instrument measurement. The paper will give all details about system components, monitoring system, and monitored data. The result of data analysis will be fully given. (author)

  4. Report on a field-portable VME-based distributed data acquisition system

    International Nuclear Information System (INIS)

    Drigert, M.W.; Cole, J.D.; Reber, E.L.; Young, J.M.

    1996-01-01

    A development effort was started two years ago to develop a portable data acquisition system which could be used for performing arms control verification and environmental monitoring measurements with complex multi-detector systems in the field. A field portable data acquisition system has been developed around a VMEbus based micro-processor and standard TCP/IP network protocols. The hardware consists of a compact VME crate and a single CAMAC crate containing the signal processing electronics. The component processes of the data acquisition system transfer control and event data over a set of TCP/IP socket connections. The use of network sockets for the interprocess communications allows the data acquisition system to be operated transparently on one workstation or on a number of workstations distributed around a local network

  5. Stability and performance of propulsion control systems with distributed control architectures and failures

    Science.gov (United States)

    Belapurkar, Rohit K.

    Future aircraft engine control systems will be based on a distributed architecture, in which, the sensors and actuators will be connected to the Full Authority Digital Engine Control (FADEC) through an engine area network. Distributed engine control architecture will allow the implementation of advanced, active control techniques along with achieving weight reduction, improvement in performance and lower life cycle cost. The performance of a distributed engine control system is predominantly dependent on the performance of the communication network. Due to the serial data transmission policy, network-induced time delays and sampling jitter are introduced between the sensor/actuator nodes and the distributed FADEC. Communication network faults and transient node failures may result in data dropouts, which may not only degrade the control system performance but may even destabilize the engine control system. Three different architectures for a turbine engine control system based on a distributed framework are presented. A partially distributed control system for a turbo-shaft engine is designed based on ARINC 825 communication protocol. Stability conditions and control design methodology are developed for the proposed partially distributed turbo-shaft engine control system to guarantee the desired performance under the presence of network-induced time delay and random data loss due to transient sensor/actuator failures. A fault tolerant control design methodology is proposed to benefit from the availability of an additional system bandwidth and from the broadcast feature of the data network. It is shown that a reconfigurable fault tolerant control design can help to reduce the performance degradation in presence of node failures. A T-700 turbo-shaft engine model is used to validate the proposed control methodology based on both single input and multiple-input multiple-output control design techniques.

  6. Generic FPGA-Based Platform for Distributed IO in Proton Therapy Patient Safety Interlock System

    Science.gov (United States)

    Eichin, Michael; Carmona, Pablo Fernandez; Johansen, Ernst; Grossmann, Martin; Mayor, Alexandre; Erhardt, Daniel; Gomperts, Alexander; Regele, Harald; Bula, Christian; Sidler, Christof

    2017-06-01

    At the Paul Scherrer Institute (PSI) in Switzerland, cancer patients are treated with protons. Proton therapy at PSI has a long history and started in the 1980s. More than 30 years later, a new gantry has recently been installed in the existing facility. This new machine has been delivered by an industry partner. A big challenge is the integration of the vendor's safety system into the existing PSI environment. Different interface standards and the complexity of the system made it necessary to find a technical solution connecting an industry system to the existing PSI infrastructure. A novel very flexible distributed IO system based on field-programmable gate array (FPGA) technology was developed, supporting many different IO interface standards and high-speed communication links connecting the device to a PSI standard versa module eurocard-bus input output controller. This paper summarizes the features of the hardware technology, the FPGA framework with its high-speed communication link protocol, and presents our first measurement results.

  7. Deployment strategy for battery energy storage system in distribution network based on voltage violation regulation

    Science.gov (United States)

    Wu, H.; Zhou, L.; Xu, T.; Fang, W. L.; He, W. G.; Liu, H. M.

    2017-11-01

    In order to improve the situation of voltage violation caused by the grid-connection of photovoltaic (PV) system in a distribution network, a bi-level programming model is proposed for battery energy storage system (BESS) deployment. The objective function of inner level programming is to minimize voltage violation, with the power of PV and BESS as the variables. The objective function of outer level programming is to minimize the comprehensive function originated from inner layer programming and all the BESS operating parameters, with the capacity and rated power of BESS as the variables. The differential evolution (DE) algorithm is applied to solve the model. Based on distribution network operation scenarios with photovoltaic generation under multiple alternative output modes, the simulation results of IEEE 33-bus system prove that the deployment strategy of BESS proposed in this paper is well adapted to voltage violation regulation invariable distribution network operation scenarios. It contributes to regulating voltage violation in distribution network, as well as to improve the utilization of PV systems.

  8. A conceptual connectivity framework for understanding geomorphic change in human-impacted fluvial systems

    Science.gov (United States)

    Pöppl, Ronald; Keesstra, Saskia; Maroulis, Jerry

    2017-04-01

    Human-induced landscape change is difficult to predict due to the complexity inherent in both geomorphic and social systems as well as due to emerging coupling relationships between them. To better understand system complexity and system response to change, connectivity has become an important research paradigm within various disciplines including geomorphology, hydrology and ecology. With the proposed conceptual connectivity framework on geomorphic change in human-impacted fluvial systems a cautionary note is flagged regarding the need (i) to include and to systematically conceptualise the role of different types of human agency in altering connectivity relationships in geomorphic systems and (ii) to integrate notions of human-environment interactions to connectivity concepts in geomorphology to better explain causes and trajectories of landscape change. Underpinned by case study examples, the presented conceptual framework is able to explain how geomorphic response of fluvial systems to human disturbance is determined by system-specific boundary conditions (incl. system history, related legacy effects and lag times), vegetation dynamics and human-induced functional relationships (i.e. feedback mechanisms) between the different spatial dimensions of connectivity. It is further demonstrated how changes in social systems can trigger a process-response feedback loop between social and geomorphic systems that further governs the trajectory of landscape change in coupled human-geomorphic systems.

  9. Distributed photovoltaic systems - Addressing the utility interface issues

    Science.gov (United States)

    Firstman, S. I.; Vachtsevanos, G. J.

    This paper reviews work conducted in the United States on the impact of dispersed photovoltaic sources upon utility operations. The photovoltaic (PV) arrays are roof-mounted on residential houses and connected, via appropriate power conditioning equipment, to the utility grid. The presence of such small (4-6 Kw) dispersed generators on the distribution network raises questions of a technical, economic and institutional nature. After a brief identification of utility interface issues, the paper addresses such technical concerns as protection of equipment and personnel safety, power quality and utility operational stability. A combination of experimental and analytical approaches has been adopted to arrive at solutions to these problems. Problem areas, under various PV system penetration scenarios, are identified and conceptual designs of protection and control equipment and operating policies are developed so that system reliability is maintained while minimizing capital costs. It is hoped that the resolution of balance-of-system and grid interface questions will ascertain the economic viability of photovoltaic systems and assist in their widespread utilization in the future.

  10. Modeling and power system stability of VSC-HVDC systems for grid-connection of large offshore windfarms

    Energy Technology Data Exchange (ETDEWEB)

    Xue Yijing [Vestas China, Beijing (China); Akhmatov, Vladislav [Technical Univ. of Denmark, Lyngby (Denmark). Centre for Electric Technology

    2009-07-01

    Utilization of Voltage Source Converter (VSC) - High Voltage Direct Current (HVDC) systems for grid-connection of large offshore windfarms becomes relevant as installed power capacities as well as distances to the connection points of on-land transmission systems increase. At the same time, the grid code requirements of the Transmission System Operators (TSO), including ancillary system services and Low-Voltage Fault-Ride-Through (LVFRT) capability of large offshore windfarms, become more demanding. This paper presents a general-level model of and a LVFRT solution for a VSC-HVDC system for grid-connection of large offshore windfarms. The VSC-HVDC model is implemented using a general approach of independent control of active and reactive power in normal operations. The on-land VSC inverter, i.e. a grid-side inverter, provides voltage support to the transmission system and comprises a LVFRT solution in short-circuit faults. The presented model, LVFRT solution and impact on the system stability are investigated as a case study of a 1,000 MW offshore windfarm grid-connected through a VSC-HVDC system. The investigation is carried out on a model of the west Danish, with some elements of the north German, 400 kV, 220 kV and 150 kV transmission systems stage 2005-2006 using the DIgSILENT PowerFactory simulation program. In the investigation, a thermal power plant just south to the Danish border has been substituted by this 1,000 MW offshore windfarm utilizing the VSC-HVDC system. The investigation has shown that the substitution of a thermal power plant by a VSC-HVDC connected offshore windfarm should not have any negative impact on the short-term stability of the west Danish transmission system. The investigation should be repeated applying updated system model stages and offshore wind power commissioning schedules in the North and Baltic Seas. (orig.)

  11. Fault Ride-Through of a Grid-connected Photovoltaic System with Quasi Z Source Inverter

    DEFF Research Database (Denmark)

    Al-Durra, Ahmed; Fayyad, Yara; Muyeen, S.M.

    2016-01-01

    This article presents fault ride-through schemes for a three-phase quasi Z source single-stage photovoltaic (PV) inverter that is connected to the grid after the distribution network. The quasi Z source inverter employs a unique LC network to couple the inverter main circuit to the input of the PV...... the grid side so that the grid fault ride-through requirements can be fulfilled. Scheme A involves control modification in the system; Schemes B and C involve hardware modification in the circuit topology by adding a chopper circuit across the DC link in Scheme B and across the quasi Z source inverter...

  12. Induced singularities of mass distributions of unstable particles connected with cascade decay and the CP-problem

    International Nuclear Information System (INIS)

    Khalfin, L.A.

    1975-01-01

    On the basis of the strong energy-momentum conservation law, the induced singularities of mass distributions of unstable particles connected with cascade decay are investigated. The possible solution of the CP-problem in the decay of Kaon neutral - Antikaon neutral mesons based on the mechanism of the induced singularities is proposed

  13. Distributed systems

    CERN Document Server

    Van Steen, Maarten

    2017-01-01

    For this third edition of "Distributed Systems," the material has been thoroughly revised and extended, integrating principles and paradigms into nine chapters: 1. Introduction 2. Architectures 3. Processes 4. Communication 5. Naming 6. Coordination 7. Replication 8. Fault tolerance 9. Security A separation has been made between basic material and more specific subjects. The latter have been organized into boxed sections, which may be skipped on first reading. To assist in understanding the more algorithmic parts, example programs in Python have been included. The examples in the book leave out many details for readability, but the complete code is available through the book's Website, hosted at www.distributed-systems.net.

  14. Economic connection consolidation by means of a small district heating house connection; Wirtschaftliche Anschlussverdichtung durch einen kleinen Fernwaermehausanschluss

    Energy Technology Data Exchange (ETDEWEB)

    John, Dietmar [enercity Netzgesellschaft mbH, Hannover (Germany); Kraft, Soenke [Fernwaerme-Forschungsinstitut GmbH, Hemmingen (Germany); Weidlich, Ingo [AGFW e.V., Frankfurt am Main (Germany)

    2013-02-01

    There a lot of technical opportunities and competing systems at the market for the last meter to the customer. These technical opportunities and competing systems enable a cost-effective construction under the prevailing general conditions. With decreasing installed power the pressure of cost increases. In the past, the enhanced number of potential customers within the lower power range up to nearly 100 kW could not be connected due to economic reasons. Thus a project with the title 'Development of an economic district heating house connection for low thermal output' was initiated. The findings supply important components for the economic expansion of district heating and are pioneering for the further development in the area of the house-installed load for heat distribution systems.

  15. Digitalized distribution system for the power supply. Internet of the energy; Digitalisiertes Verteilungsnetz fuer die Stromversorgung. Internet der Energie

    Energy Technology Data Exchange (ETDEWEB)

    Reifenhaeuser, Bernd; Ebbes, Alexander [GIP AG, Mainz (Germany)

    2013-05-13

    Current power distribution systems are highly connected with each other, redundantly designed with respect to the security of supply and require a central planning. Due to the close interlocking, disturbances may spread quickly and lead to a large-scale blackout. In order to counteract failures in the face of an increasing share of renewable energy, energy has to be hold out - an inefficient and expensive reserve. A decentralized, digital power distribution system may handle the task much better.

  16. The Integration and Control of Multifunctional Stationary PV-Battery Systems in Smart Distribution Grid

    DEFF Research Database (Denmark)

    Khan, Mohammad Rezwan; Mulder, Grietus; Van Mierlo, Joeri

    2013-01-01

    The paper investigates the potential of using lumped stationary battery energy storage systems (BESS) in the public low-voltage distribution grid in order to defer upgrades needed in case of large penetration of electric vehicle (EV), electrified heat pump (HP) in presence of photovoltaic (PV....... The objective of this paper is to develop and detail the method of optimum sizing energy storage for grid connected distribution systems using newly devised BESS control protocol and investigate its sensitivity to factors which are known to influence energy system performance and hence storage requirements......) panel on the view of techno economic optimal sizing taking the consideration of season-based diurnal dynamics. The BESS is primarily dimensioned for the peak shaving operation targeted for the counterbalance of overloading of transformer; BESS also participates in arbitrage (buy low, sell high...

  17. Model Predictive Control of Grid Connected Modular Multilevel Converter for Integration of Photovoltaic Power Systems

    DEFF Research Database (Denmark)

    Hajizadeh, Amin; Shahirinia, Amir

    2017-01-01

    Investigation of an advanced control structure for integration of Photovoltaic Power Systems through Grid Connected-Modular Multilevel Converter (GC-MMC) is proposed in this paper. To achieve this goal, a non-linear model of MMC regarding considering of negative and positive sequence components has...... been presented. Then, due to existence of unbalance voltage faults in distribution grid, non-linarites and uncertainties in model, model predictive controller which is developed for GC-MMC. They are implemented based upon positive and negative components of voltage and current to mitigate the power...

  18. Fundamentals of Grid Connected Photo-Voltaic Power Electronic Converter Design

    OpenAIRE

    Evju, Svein Erik

    2007-01-01

    In this master thesis the basic theory of grid connected photo-voltaic systems is explained, giving an introduction to the different aspects of system design. Starting with a look at the standards concerning grid connection of distributed resources, and working its way through how the photo-voltaic cells work, to how photo-voltaic modules with electrical converters can be arranged. Some different converter topologies suitable for use with photo-voltaics are found, and based on these topologie...

  19. Distributed security in closed distributed systems

    DEFF Research Database (Denmark)

    Hernandez, Alejandro Mario

    properties. This is also restricted to distributed systems in which the set of locations is known a priori. All this follows techniques borrowed from both the model checking and the static analysis communities. In the end, we reach a step towards solving the problem of enforcing security in distributed...... systems. We achieve the goal of showing how this can be done, though we restrict ourselves to closed systems and with a limited set of enforceable security policies. In this setting, our approach proves to be efficient. Finally, we achieve all this by bringing together several fields of Computer Science......The goal of the present thesis is to discuss, argue and conclude about ways to provide security to the information travelling around computer systems consisting of several known locations. When developing software systems, security of the information managed by these plays an important role...

  20. Design and Realization of Online Monitoring System of Distributed New Energy and Renewable Energy

    Science.gov (United States)

    Tang, Yanfen; Zhou, Tao; Li, Mengwen; Zheng, Guotai; Li, Hao

    2018-01-01

    Aimed at difficult centralized monitoring and management of current distributed new energy and renewable energy generation projects due to great varieties, different communication protocols and large-scale difference, this paper designs a online monitoring system of new energy and renewable energy characterized by distributed deployment, tailorable functions, extendible applications and fault self-healing performance. This system is designed based on international general standard for grid information data model, formulates unified data acquisition and transmission standard for different types of new energy and renewable energy generation projects, and can realize unified data acquisition and real-time monitoring of new energy and renewable energy generation projects, such as solar energy, wind power, biomass energy, etc. within its jurisdiction. This system has applied in Beijing. At present, 576 projects are connected to the system. Good effect is achieved and stability and reliability of the system have been validated.

  1. Distribution system modeling and analysis

    CERN Document Server

    Kersting, William H

    2001-01-01

    For decades, distribution engineers did not have the sophisticated tools developed for analyzing transmission systems-often they had only their instincts. Things have changed, and we now have computer programs that allow engineers to simulate, analyze, and optimize distribution systems. Powerful as these programs are, however, without a real understanding of the operating characteristics of a distribution system, engineers using the programs can easily make serious errors in their designs and operating procedures. Distribution System Modeling and Analysis helps prevent those errors. It gives readers a basic understanding of the modeling and operating characteristics of the major components of a distribution system. One by one, the author develops and analyzes each component as a stand-alone element, then puts them all together to analyze a distribution system comprising the various shunt and series devices for power-flow and short-circuit studies. He includes the derivation of all models and includes many num...

  2. Synchronization in single-phase grid-connected photovoltaic systems under grid faults

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2012-01-01

    The highly increasing penetration of single-phase photovoltaic (PV) systems pushes the grid requirements related to the integration of PV power systems to be updated. These upcoming regulations are expected to direct the grid-connected renewable generators to support the grid operation and stabil......The highly increasing penetration of single-phase photovoltaic (PV) systems pushes the grid requirements related to the integration of PV power systems to be updated. These upcoming regulations are expected to direct the grid-connected renewable generators to support the grid operation...

  3. Development of a software application to evaluate the performance and energy losses of grid-connected photovoltaic systems

    International Nuclear Information System (INIS)

    Trillo-Montero, D.; Santiago, I.; Luna-Rodriguez, J.J.; Real-Calvo, R.

    2014-01-01

    Highlights: • Software application to perform an automated analysis of grid-connected PV systems. • It integrates data from all devices registering data on typical PV installations. • Flexible to analyze installations with different configurations and components. • An analysis of two grid-connected PV systems located in Andalusia, was performed. • Temperature losses in summer months varying between 15% and 25% of energy production. - Abstract: The aim of this paper was to design and develop a software application that enables users to perform an automated analysis of data from the monitoring of grid-connected photovoltaic (PV) systems. This application integrates data from all devices already in operation such as environmental sensors, inverters and meters, which record information on typical PV installations. This required the development of a Relational Database Management System (RDBMS), consisting of a series of linked databases, enabling all PV system information to be stored; and a software, called S·lar, which enables all information from the monitoring to be automatically migrated to the database as well as determining some standard magnitudes related to performances and losses of PV installation components at different time scales. A visualization tool, which is both graphical and numerical, makes access to all of the information be a simple task. Moreover, the application enables relationships between parameters and/or magnitudes to be easily established. Furthermore, it can perform a preliminary analysis of the influence of PV installations on the distribution grids where the produced electricity is injected. The operation of such a software application was implemented by performing the analysis of two grid-connected PV installations located in Andalusia, Spain, via data monitoring therein. The monitoring took place from January 2011 to May 2012

  4. Automatic generation of water distribution systems based on GIS data.

    Science.gov (United States)

    Sitzenfrei, Robert; Möderl, Michael; Rauch, Wolfgang

    2013-09-01

    In the field of water distribution system (WDS) analysis, case study research is needed for testing or benchmarking optimisation strategies and newly developed software. However, data availability for the investigation of real cases is limited due to time and cost needed for data collection and model setup. We present a new algorithm that addresses this problem by generating WDSs from GIS using population density, housing density and elevation as input data. We show that the resulting WDSs are comparable to actual systems in terms of network properties and hydraulic performance. For example, comparing the pressure heads for an actual and a generated WDS results in pressure head differences of ±4 m or less for 75% of the supply area. Although elements like valves and pumps are not included, the new methodology can provide water distribution systems of varying levels of complexity (e.g., network layouts, connectivity, etc.) to allow testing design/optimisation algorithms on a large number of networks. The new approach can be used to estimate the construction costs of planned WDSs aimed at addressing population growth or at comparisons of different expansion strategies in growth corridors.

  5. Overview of Single-Phase Grid-Connected Photovoltaic Systems

    OpenAIRE

    Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    A still booming installation of solar photovoltaic (PV) systems has been witnessed worldwide. It is mainly driven by the demand of “clean” power generation. Grid-connected PV systems will become an even active player in the future mixed power systems, which are linked by a vast of power electronics converters. In order to achieve a reliable and efficient power generation from PV systems, stringent demands have been imposed on the entire PV system. It in return advances the development of powe...

  6. Increased functional connectivity between prefrontal cortex and reward system in pathological gambling.

    Directory of Open Access Journals (Sweden)

    Saskia Koehler

    Full Text Available Pathological gambling (PG shares clinical characteristics with substance-use disorders and is thus discussed as a behavioral addiction. Recent neuroimaging studies on PG report functional changes in prefrontal structures and the mesolimbic reward system. While an imbalance between these structures has been related to addictive behavior, whether their dysfunction in PG is reflected in the interaction between them remains unclear. We addressed this question using functional connectivity resting-state fMRI in male subjects with PG and controls. Seed-based functional connectivity was computed using two regions-of-interest, based on the results of a previous voxel-based morphometry study, located in the prefrontal cortex and the mesolimbic reward system (right middle frontal gyrus and right ventral striatum. PG patients demonstrated increased connectivity from the right middle frontal gyrus to the right striatum as compared to controls, which was also positively correlated with nonplanning aspect of impulsiveness, smoking and craving scores in the PG group. Moreover, PG patients demonstrated decreased connectivity from the right middle frontal gyrus to other prefrontal areas as compared to controls. The right ventral striatum demonstrated increased connectivity to the right superior and middle frontal gyrus and left cerebellum in PG patients as compared to controls. The increased connectivity to the cerebellum was positively correlated with smoking in the PG group. Our results provide further evidence for alterations in functional connectivity in PG with increased connectivity between prefrontal regions and the reward system, similar to connectivity changes reported in substance use disorder.

  7. Cooling water distribution system

    Science.gov (United States)

    Orr, Richard

    1994-01-01

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  8. Research on simulated devices for Solar photovoltaic grid-connected generation system

    Directory of Open Access Journals (Sweden)

    quan-zhu Zhang

    2017-01-01

    Full Text Available On the standpoint of energy conservation and emission reduction, one device simulated photovoltaic grid-connected generation system based on SPWM was designed in the paper. And DC/AC inverter could transduce efficiently direct current to alternating current. The MCU(Micro-Control-Unit, in this system could achieve the control method for maximum-power-point and tracking for frequency and phase. Moreover, the MCU could implement PWM (Plus-Width Modulating through programming. The system showed clearly the whole photovoltaic grid-connected generation system using simulated methods and ways.

  9. Grid-connected photovoltaic system design for local government ...

    African Journals Online (AJOL)

    Grid-connected photovoltaic system design for local government offices in Nigeria. ... Nigerian Journal of Technology. Journal Home ... It is neat, silent and elegant process of generating electric power in environmentally friendly manner. In this ...

  10. Systemic inflammation and resting state connectivity of the default mode network.

    Science.gov (United States)

    Marsland, Anna L; Kuan, Dora C-H; Sheu, Lei K; Krajina, Katarina; Kraynak, Thomas E; Manuck, Stephen B; Gianaros, Peter J

    2017-05-01

    The default mode network (DMN) encompasses brain systems that exhibit coherent neural activity at rest. DMN brain systems have been implicated in diverse social, cognitive, and affective processes, as well as risk for forms of dementia and psychiatric disorders that associate with systemic inflammation. Areas of the anterior cingulate cortex (ACC) and surrounding medial prefrontal cortex (mPFC) within the DMN have been implicated specifically in regulating autonomic and neuroendocrine processes that relate to systemic inflammation via bidirectional signaling mechanisms. However, it is still unclear whether indicators of inflammation relate directly to coherent resting state activity of the ACC, mPFC, or other areas within the DMN. Accordingly, we tested whether plasma interleukin (IL)-6, an indicator of systemic inflammation, covaried with resting-state functional connectivity of the DMN among 98 adults aged 30-54 (39% male; 81% Caucasian). Independent component analyses were applied to resting state fMRI data to generate DMN connectivity maps. Voxel-wise regression analyses were then used to test for associations between IL-6 and DMN connectivity across individuals, controlling for age, sex, body mass index, and fMRI signal motion. Within the DMN, IL-6 covaried positively with connectivity of the sub-genual ACC and negatively with a region of the dorsal medial PFC at corrected statistical thresholds. These novel findings offer evidence for a unique association between a marker of systemic inflammation (IL-6) and ACC and mPFC functional connectivity within the DMN, a network that may be important for linking aspects of immune function to psychological and behavioral states in health and disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Development of an Advanced Grid-Connected PV-ECS System Considering Solar Energy Estimation

    Science.gov (United States)

    Rahman, Md. Habibur; Yamashiro, Susumu; Nakamura, Koichi

    In this paper, the development and the performance of a viable distributed grid-connected power generation system of Photovoltaic-Energy Capacitor System (PV-ECS) considering solar energy estimation have been described. Instead of conventional battery Electric Double Layer Capacitors (EDLC) are used as storage device and Photovoltaic (PV) panel to generate power from solar energy. The system can generate power by PV, store energy when the demand of load is low and finally supply the stored energy to load during the period of peak demand. To realize the load leveling function properly the system will also buy power from grid line when load demand is high. Since, the power taken from grid line depends on the PV output power, a procedure has been suggested to estimate the PV output power by calculating solar radiation. In order to set the optimum value of the buy power, a simulation program has also been developed. Performance of the system has been studied for different load patterns in different weather conditions by using the estimated PV output power with the help of the simulation program.

  12. Grey matter connectivity within and between auditory, language and visual systems in prelingually deaf adolescents.

    Science.gov (United States)

    Li, Wenjing; Li, Jianhong; Wang, Zhenchang; Li, Yong; Liu, Zhaohui; Yan, Fei; Xian, Junfang; He, Huiguang

    2015-01-01

    Previous studies have shown brain reorganizations after early deprivation of auditory sensory. However, changes of grey matter connectivity have not been investigated in prelingually deaf adolescents yet. In the present study, we aimed to investigate changes of grey matter connectivity within and between auditory, language and visual systems in prelingually deaf adolescents. We recruited 16 prelingually deaf adolescents and 16 age-and gender-matched normal controls, and extracted the grey matter volume as the structural characteristic from 14 regions of interest involved in auditory, language or visual processing to investigate the changes of grey matter connectivity within and between auditory, language and visual systems. Sparse inverse covariance estimation (SICE) was utilized to construct grey matter connectivity between these brain regions. The results show that prelingually deaf adolescents present weaker grey matter connectivity within auditory and visual systems, and connectivity between language and visual systems declined. Notably, significantly increased brain connectivity was found between auditory and visual systems in prelingually deaf adolescents. Our results indicate "cross-modal" plasticity after deprivation of the auditory input in prelingually deaf adolescents, especially between auditory and visual systems. Besides, auditory deprivation and visual deficits might affect the connectivity pattern within language and visual systems in prelingually deaf adolescents.

  13. Harmonic resonance assessment of multiple paralleled grid-connected inverters system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    This paper presents an eigenvalue-based impedance stability analytical method of multiple paralleled grid-connected inverter system. Different from the conventional impedance-based stability criterion, this work first built the state-space model of paralleled grid-connected inverters. On the basis...... of this, a bridge between the state-space-based modelling and impedance-based stability criterion is presented. The proposed method is able to perform stability assessment locally at the connection points of the component. Meanwhile, the eigenvalue-based sensitivity analysis is adopted to identify...

  14. Evolving hydrologic connectivity in discontinuous permafrost lowlands: what it means for lake systems

    Science.gov (United States)

    Walvoord, M. A.; Jepsen, S. M.; Rover, J.; Voss, C. I.; Briggs, M. A.

    2015-12-01

    Permafrost influence on the hydrologic connectivity of surface water bodies in high-latitude lowlands is complicated by subsurface heterogeneity and the propensity of the system to change over time. In general, permafrost limits the subsurface exchange of water, solute, and nutrients between lakes and rivers. It follows that permafrost thaw could enhance subsurface hydrologic connectivity among surface water bodies, but the impact of this process on lake distribution is not well known. Changes in the extent of lakes in interior Alaska have important ecological and societal impacts since lakes provide (1) critical habitat for migratory arctic shorebirds and waterfowl, fish, and wildlife, and (2) provisional, recreational, and cultural resources for local communities. We utilize electromagnetic imaging of the shallow subsurface and remote sensing of lake level dynamics in the Yukon Flats of interior Alaska, USA, together with water balance modeling, to gain insight into the influence of discontinuous permafrost on lowland lake systems. In the study region with relatively low precipitation, observations suggest that lakes that are hydrologically isolated during normal conditions are sustained by periodic river flooding events, including ice-jam floods that occur during river ice break-up. Climatically-influenced alterations in flooding frequency and intensity, as well as depth to permafrost, are quantitatively assessed in the context of lake maintenance. Scenario modeling is used to evaluate lake level evolution under plausible changing conditions. Model results demonstrate how permafrost degradation can reduce the dependence of typical lowland lakes on flooding events. Study results also suggest that river flooding may recharge a more spatially widespread zone of lakes and wetlands under future scenarios of permafrost table deepening and enhanced subsurface hydrologic connectivity.

  15. A Modular Framework for Modeling Hardware Elements in Distributed Engine Control Systems

    Science.gov (United States)

    Zinnecker, Alicia M.; Culley, Dennis E.; Aretskin-Hariton, Eliot D.

    2015-01-01

    Progress toward the implementation of distributed engine control in an aerospace application may be accelerated through the development of a hardware-in-the-loop (HIL) system for testing new control architectures and hardware outside of a physical test cell environment. One component required in an HIL simulation system is a high-fidelity model of the control platform: sensors, actuators, and the control law. The control system developed for the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) provides a verifiable baseline for development of a model for simulating a distributed control architecture. This distributed controller model will contain enhanced hardware models, capturing the dynamics of the transducer and the effects of data processing, and a model of the controller network. A multilevel framework is presented that establishes three sets of interfaces in the control platform: communication with the engine (through sensors and actuators), communication between hardware and controller (over a network), and the physical connections within individual pieces of hardware. This introduces modularity at each level of the model, encouraging collaboration in the development and testing of various control schemes or hardware designs. At the hardware level, this modularity is leveraged through the creation of a SimulinkR library containing blocks for constructing smart transducer models complying with the IEEE 1451 specification. These hardware models were incorporated in a distributed version of the baseline C-MAPSS40k controller and simulations were run to compare the performance of the two models. The overall tracking ability differed only due to quantization effects in the feedback measurements in the distributed controller. Additionally, it was also found that the added complexity of the smart transducer models did not prevent real-time operation of the distributed controller model, a requirement of an HIL system.

  16. High Voltage Distribution System (HVDS) as a better system compared to Low Voltage Distribution System (LVDS) applied at Medan city power network

    Science.gov (United States)

    Dinzi, R.; Hamonangan, TS; Fahmi, F.

    2018-02-01

    In the current distribution system, a large-capacity distribution transformer supplies loads to remote locations. The use of 220/380 V network is nowadays less common compared to 20 kV network. This results in losses due to the non-optimal distribution transformer, which neglected the load location, poor consumer profile, and large power losses along the carrier. This paper discusses how high voltage distribution systems (HVDS) can be a better system used in distribution networks than the currently used distribution system (Low Voltage Distribution System, LVDS). The proposed change of the system into the new configuration is done by replacing a large-capacity distribution transformer with some smaller-capacity distribution transformers and installed them in positions that closest to the load. The use of high voltage distribution systems will result in better voltage profiles and fewer power losses. From the non-technical side, the annual savings and payback periods on high voltage distribution systems will also be the advantage.

  17. MODELS AND SOLUTIONS FOR THE IMPLEMENTATION OF DISTRIBUTED SYSTEMS

    Directory of Open Access Journals (Sweden)

    Tarca Naiana

    2011-07-01

    Full Text Available Software applications may have different degrees of complexity depending on the problems they try to solve and can integrate very complex elements that bring together functionality that sometimes are competing or conflicting. We can take for example a mobile communications system. Functionalities of such a system are difficult to understand, and they add to the non-functional requirements such as the use in practice, performance, cost, durability and security. The transition from local computer networks to cover large networks that allow millions of machines around the world at speeds exceeding one gigabit per second allowed universal access to data and design of applications that require simultaneous use of computing power of several interconnected systems. The result of these technologies has enabled the evolution from centralized to distributed systems that connect a large number of computers. To enable the exploitation of the advantages of distributed systems one had developed software and communications tools that have enabled the implementation of distributed processing of complex solutions. The objective of this document is to present all the hardware, software and communication tools, closely related to the possibility of their application in integrated social and economic level as a result of globalization and the evolution of e-society. These objectives and national priorities are based on current needs and realities of Romanian society, while being consistent with the requirements of Romania's European orientation towards the knowledge society, strengthening the information society, the target goal representing the accomplishment of e-Romania, with its strategic e-government component. Achieving this objective repositions Romania and gives an advantage for sustainable growth, positive international image, rapid convergence in Europe, inclusion and strengthening areas of high competence, in line with Europe 2020, launched by the

  18. Three-phase electronic power converter for photovoltaic system connected to power line; Conversor eletronico de potencia trifasico para sistema fotovoltaico conectado a rede eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Villalva, Marcelo Gradella

    2010-10-15

    This work is a contribution to the study of power converters for photovoltaic distributed generation systems. The main objective is to present the development and results of a three phase power converter for a grid-connected photovoltaic plant. The work presents experimental results and theoretical studies on the modeling and simulation of photovoltaic devices, regulation of the photovoltaic voltage, maximum power point tracking, and the modeling and control of a two-stage grid-connected power converter. (author)

  19. Control strategies for gas turbine generators for grid connected and islanding operations

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    fine while a DG is connected to a grid, might not work as desired while it is islanded and vise versa. This paper presents a strategy to operate distribution systems with a small gas turbine generator (GTG), which is capable of supplying local loads, in both islanding and grid connected conditions...

  20. System Modeling and Trust Evaluation of Distributed Systems

    OpenAIRE

    Alhadad , Nagham; Serrano-Alvarado , Patricia; Busnel , Yann; Lamarre , Philippe

    2015-01-01

    International audience; Nowadays, digital systems are connected through complex architectures. These systems involve persons, physical and digital resources such that we can consider that a system consists of elements from two worlds, the social world and the digital world, and their relations. Users perform activities like chatting, buying, sharing data, etc. Evaluating and choosing appropriate systems involve aspects like functionality, performance, QoS, ease of use, or price. Recently, tru...

  1. FY 2000 report on the demonstrative research for photovoltaic power generation system in Thailand. Demonstrative study on photovoltaic power generation grid-connected system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    In relation to the demonstrative study of the photovoltaic power system that is planned in Libong island, Thailand, the FY 2000 results were reported. In this R and D, construction/demonstrative operation were planned for a photovoltaic power station with a generation output of 100kW, photovoltaic power system in school facilities, and system for transmitting/distributing power to houses by connecting the power station and power system. In this fiscal year, the field survey was conducted together with the alteration from Yao Yai island, for which the demonstrative study was planned at first, to Libong island. The electric equipment was selected which met the requests from Thailand and the results of the field survey, and the basic design of the photovoltaic power generation/transmission/distribution system was completed. Based on this, the design/manufacture of photovoltaic power generation modules, power control equipment, measuring equipment, etc. were made. At the construction site of photovoltaic power station, construction work such as land formation was conducted. Further, Thai engineers who visited Japan did the following: discussions about power system, presence at test/inspection of photovoltaic power generation modules, visits to photovoltaic power stations, wind power stations, etc. (NEDO)

  2. Decentralized electricity generation by using photovoltaic grid-connected solar system

    International Nuclear Information System (INIS)

    Tyutyundziev, N.; Vitanov, P.; Radkov, R.; Grottke, M.

    2006-01-01

    AcadPV is the first demonstration installation connected permanently to LV grid in Sofia, Bulgaria aiming at assessment of PV efficiencies and cost-effectiveness. A thorough analysis has been carried out in order to select PV system site, supporting construction design and orientation. The PV generator is divided to 3 PV subfields equipped by 3 SUNPOWER inverters connected to 3 separated phases of the grid. The performance of 10kWp PV system has been evaluated during the first year of operation and compared to PV simulation software results

  3. Electrical system studies for the grid connection of wind farms

    International Nuclear Information System (INIS)

    Arp, K.; Hanson, J.; Hopp, S.; Zimmermann, W.

    2007-01-01

    Wind power is gaining momentum in the world's energy balance. Several issues have to be addressed whenever power-generating devices are connected to the grid. The paper describes studies needed to evaluate the influence of wind farms on the connected transmission system and how faults in the system impact on induction generators in a wind farm. Some generalized results of studies for an offshore wind farm in the North Sea and a Bulgarian wind farm show how studies can influence the layout of the internal network and the electrical equipment. (authors)

  4. Snaps to Connect Coaxial and Microstrip Lines in Wearable Systems

    Directory of Open Access Journals (Sweden)

    Tiiti Kellomäki

    2012-01-01

    Full Text Available Commercial snaps (clothing fasteners can be used to connect a coaxial cable to a microstrip line. This is useful in the context of wearable antennas, especially in consumer applications and disposable connections. The measured S-parameters of the transition are presented, and an equivalent circuit and approximate equations are derived for system design purposes. The proposed connection is usable up to 1.5 GHz (10 dB return loss condition, and the frequency range can be extended to 2 GHz if a thinner, more flexible coaxial cable is used.

  5. Distributed Cooperative Control of Multi Flywheel Energy Storage System for Electrical Vehicle Fast Charging Stations

    DEFF Research Database (Denmark)

    Sun, Bo; Dragicevic, Tomislav; Quintero, Juan Carlos Vasquez

    2015-01-01

    Plug-in electrical vehicles will play a critical role in future smart grid and sudden connection of electrical vehicles chargers may cause huge power-peaks with high slew-rates on grid. In order to cope with this issue, this paper applies a distributed cooperative control for fast charging station...... with dedicated paralleled flywheel-based energy storage system. The distributed DC-bus signaling method is employed in the power coordination of grid and flywheel converters, and a distributed secondary controller generates DC voltage correction term to adjust the local voltage set-point through a dynamic...... consensus based voltage observer by communicating with its neighbors. The control system can realize the power balancing and DC voltage regulation with low reliance on communications. Finally, real-time hardware-in-the-loop results have been reported in order to verify the feasibility of proposed approach....

  6. The DFBX cryogenic distribution boxes for the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Green, Michael A.; Kajiyama, Y.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    The DFBX distribution boxes are designed to connect the LHC cryogenic distribution system to the interaction region quadrupoles [1] and dipoles for the Large Hadron Collider (LHC). The DFBX distribution boxes also have the current leads for the superconducting interaction region magnets and the LHC interaction region correction coils. The DFBX boxes also connect the magnet and cryogenic instrumentation to the CERN data collection system. The DFBX boxes serve as the cryogenic circulation center and the nerve center for four of the LHC straight sections. This report describes primarily the cryogenic function of the DFBXs

  7. Factorization and the synthesis of optimal feedback gains for distributed parameter systems

    Science.gov (United States)

    Milman, Mark H.; Scheid, Robert E.

    1990-01-01

    An approach based on Volterra factorization leads to a new methodology for the analysis and synthesis of the optimal feedback gain in the finite-time linear quadratic control problem for distributed parameter systems. The approach circumvents the need for solving and analyzing Riccati equations and provides a more transparent connection between the system dynamics and the optimal gain. The general results are further extended and specialized for the case where the underlying state is characterized by autonomous differential-delay dynamics. Numerical examples are given to illustrate the second-order convergence rate that is derived for an approximation scheme for the optimal feedback gain in the differential-delay problem.

  8. Basis for a new product programme for fluid connections in

    DEFF Research Database (Denmark)

    Voigt, Kristian

    1999-01-01

    If one decides to make a new product programme for fluid connections (known as tubes, hoses, fittings) certain conditions should be taken into consideration. This include which functionality that is needed, what the different stakeholders demand from the product programme, how the functionality...... is distributed between the fluid connections and other system components, which phenomena there is of interest and how to deal with them. This paper can provide help when a specification has to be set up for a new product programme for fluid connections....

  9. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  10. Economic Model Predictive Control for Large-Scale and Distributed Energy Systems

    DEFF Research Database (Denmark)

    Standardi, Laura

    Sources (RESs) in the smart grids is increasing. These energy sources bring uncertainty to the production due to their fluctuations. Hence,smart grids need suitable control systems that are able to continuously balance power production and consumption.  We apply the Economic Model Predictive Control (EMPC......) strategy to optimise the economic performances of the energy systems and to balance the power production and consumption. In the case of large-scale energy systems, the electrical grid connects a high number of power units. Because of this, the related control problem involves a high number of variables......In this thesis, we consider control strategies for large and distributed energy systems that are important for the implementation of smart grid technologies.  An electrical grid has to ensure reliability and avoid long-term interruptions in the power supply. Moreover, the share of Renewable Energy...

  11. A distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Verho, P.; Jaerventausta, P.; Kaerenlampi, M.; Paulasaari, H. [Tampere Univ. of Technology (Finland); Partanen, J. [Lappeenranta Univ. of Technology (Finland)

    1996-12-31

    The development of new distribution automation applications is considerably wide nowadays. One of the most interesting areas is the development of a distribution management system (DMS) as an expansion of the traditional SCADA system. At the power transmission level such a system is called an energy management system (EMS). The idea of these expansions is to provide supporting tools for control center operators in system analysis and operation planning. The needed data for new applications is mainly available in some existing systems. Thus the computer systems of utilities must be integrated. The main data source for the new applications in the control center are the AM/FM/GIS (i.e. the network database system), the SCADA, and the customer information system (CIS). The new functions can be embedded in some existing computer system. This means a strong dependency on the vendor of the existing system. An alternative strategy is to develop an independent system which is integrated with other computer systems using well-defined interfaces. The latter approach makes it possible to use the new applications in various computer environments, having only a weak dependency on the vendors of the other systems. In the research project this alternative is preferred and used in developing an independent distribution management system

  12. A distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Verho, P; Jaerventausta, P; Kaerenlampi, M; Paulasaari, H [Tampere Univ. of Technology (Finland); Partanen, J [Lappeenranta Univ. of Technology (Finland)

    1997-12-31

    The development of new distribution automation applications is considerably wide nowadays. One of the most interesting areas is the development of a distribution management system (DMS) as an expansion of the traditional SCADA system. At the power transmission level such a system is called an energy management system (EMS). The idea of these expansions is to provide supporting tools for control center operators in system analysis and operation planning. The needed data for new applications is mainly available in some existing systems. Thus the computer systems of utilities must be integrated. The main data source for the new applications in the control center are the AM/FM/GIS (i.e. the network database system), the SCADA, and the customer information system (CIS). The new functions can be embedded in some existing computer system. This means a strong dependency on the vendor of the existing system. An alternative strategy is to develop an independent system which is integrated with other computer systems using well-defined interfaces. The latter approach makes it possible to use the new applications in various computer environments, having only a weak dependency on the vendors of the other systems. In the research project this alternative is preferred and used in developing an independent distribution management system

  13. New Approaches for Very Short-term Steady-State Analysis of An Electrical Distribution System with Wind Farms

    Directory of Open Access Journals (Sweden)

    Antonio Bracale

    2010-04-01

    Full Text Available Distribution networks are undergoing radical changes due to the high level of penetration of dispersed generation. Dispersed generation systems require particular attention due to their incorporation of uncertain energy sources, such as wind farms, and due to the impacts that such sources have on the planning and operation of distribution networks. In particular, the foreseeable, extensive use of wind turbine generator units in the future requires that distribution system engineers properly account for their impacts on the system. Many new technical considerations must be addressed, including protection coordination, steady-state analysis, and power quality issues. This paper deals with the very short-term, steady-state analysis of a distribution system with wind farms, for which the time horizon of interest ranges from one hour to a few hours ahead. Several wind-forecasting methods are presented in order to obtain reliable input data for the steady-state analysis. Both deterministic and probabilistic methods were considered and used in performing deterministic and probabilistic load-flow analyses. Numerical applications on a 17-bus, medium-voltage, electrical distribution system with various wind farms connected at different busbars are presented and discussed.

  14. RBAC Administration in Distributed Systems

    NARCIS (Netherlands)

    Dekker, M.A.C.; Crampton, J.; Etalle, Sandro

    2007-01-01

    Despite a large body of literature on the administration of RBAC policies in centralized systems, the problem of the administration of a distributed system has hardly been addressed. We present a formal system for modelling a distributed RBAC system and its administration. We define two basic

  15. Study concerning the power plant control and safety equipment by integrated distributed systems

    International Nuclear Information System (INIS)

    Optea, I.; Oprea, M.; Stanescu, P.

    1995-01-01

    The paper deals with the trends existing in the field of nuclear control and safety equipment and systems, proposing a high-efficiency integrated system. In order to enhance the safety of the plant and reliability of the structure system and components, we present a concept based on the latest computer technology with an open, distributed system, connected by a local area network with high redundancy. A modern conception for the control and safety system is to integrate all the information related to the reactor protection, active engineered safeguard and auxiliary systems parameters, offering a fast flow of information between all the agencies concerned so that situations can be quickly assessed. The integrated distributed control is based on a high performance operating system for realtime applications, flexible enough for transparent networking and modular for demanding configurations. The general design considerations for nuclear reactors instrumentation reliability and testing methods for real-time functions under dynamic regime are presented. Taking into account the fast progress in information technology, we consider the replacement of the old instrumentation of Cernavoda-1 NPP by a modern integrated system as an economical and efficient solution for the next units. (Author) 20 Refs

  16. Design of distributed systems of hydrolithosphere processes management. A synthesis of distributed management systems

    Science.gov (United States)

    Pershin, I. M.; Pervukhin, D. A.; Ilyushin, Y. V.; Afanaseva, O. V.

    2017-10-01

    The paper considers an important problem of designing distributed systems of hydrolithosphere processes management. The control actions on the hydrolithosphere processes under consideration are implemented by a set of extractive wells. The article shows the method of defining the approximation links for description of the dynamic characteristics of hydrolithosphere processes. The structure of distributed regulators, used in the management systems by the considered processes, is presented. The paper analyses the results of the synthesis of the distributed management system and the results of modelling the closed-loop control system by the parameters of the hydrolithosphere process.

  17. Communication Facilities for Distributed Systems

    Directory of Open Access Journals (Sweden)

    V. Barladeanu

    1997-01-01

    Full Text Available The design of physical networks and communication protocols in Distributed Systems can have a direct impact on system efficiency and reliability. This paper tries to identify efficient mechanisms and paradigms for communication in distributed systems.

  18. Modeling Of Components Of A Photovoltaic System With Voltage Inverter For Connection To The Electrical Grid

    International Nuclear Information System (INIS)

    Ferreira, Andreza C.; Blasques, Luis C. M.; Galhardo, Marcos A. B.; Pinho, João T.

    2017-01-01

    This paper describes the modeling of the electrical equipment and control mechanisms used in the power conditioning system of a grid-connected photovoltaic system (GCPVS), such as the photovoltaic generator, the DC/DC converter, the voltage inverter with PWM control, its output filter, as well as the converter controls and their functionalities, and the interconnection of the system with the distribution grid and load. In addition to the modeling of the grid-tie inverter, the main equipment of the power conditioning system, this paper describes the synchronization form of the photovoltaic (PV) generation with the electricity distribution grid, considering the power injection control method, the maximum power point tracking technique for maximizing the energy supplied by the photovoltaic generator, and the complete topology of the proposed PV system. The main objective is to provide a computational model capable of simulating the behavior of the GCPVS elements, varying the climatic conditions and the power demand on the AC side, presenting consistent results for different operating conditions, such as variations of climatic parameters (solar irradiance, wind speed, and ambient temperature) and load. In these cases, it is possible to evaluate the behavior of the system, sometimes supplying both the active and reactive power of the load, according to the need. (author)

  19. Understanding ecohydrological connectivity in savannas: A system dynamics modeling approach

    Science.gov (United States)

    Ecohydrological connectivity is a system-level property that results from the linkages in the networks of water transport through ecosystems, by which feedback effects and other emergent system behaviors may be generated. We created a systems dynamic model that represents primary ecohydrological net...

  20. Studying the Impact of Distributed Solar PV on Power Systems using Integrated Transmission and Distribution Models: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Himanshu [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Palmintier, Bryan S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Krad, Ibrahim [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Krishnamurthy, Dheepak [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-24

    This paper presents the results of a distributed solar PV impact assessment study that was performed using a synthetic integrated transmission (T) and distribution (D) model. The primary objective of the study was to present a new approach for distributed solar PV impact assessment, where along with detailed models of transmission and distribution networks, consumer loads were modeled using the physics of end-use equipment, and distributed solar PV was geographically dispersed and connected to the secondary distribution networks. The highlights of the study results were (i) increase in the Area Control Error (ACE) at high penetration levels of distributed solar PV; and (ii) differences in distribution voltages profiles and voltage regulator operations between integrated T&D and distribution only simulations.

  1. Underfrequency Load Shedding for an Islanded Distribution System With Distributed Generators

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    Significant penetration of distributed generation in many distribution systems has opened an option of operating distribution systems in island mode for economical and technical reasons. However, balancing frequency of the islanded system is still an issue to be solved, especially when the demand...

  2. Vegetation Patchiness Enhances Hydrological Connectivity in River Deltas Below the Percolation Threshold

    Science.gov (United States)

    Wright, K. A.; Hiatt, M. R.; Passalacqua, P.

    2017-12-01

    The humanitarian and ecological importance of coastal deltas has led many to research the factors influencing their ecogeomorphic evolution, in hopes of predicting the response of these regions to the growing number of natural and anthropogenic threats they face. One area of this effort, in which many unresolved questions remain, concerns the hydrological connectivity between the distributary channels and interdistributary islands, which field observations and numerical modeling have shown to be significant. Island vegetation is known to affect the degree of connectivity, but the effect of the spatial distribution of vegetation on connectivity remains an important question. This research aims to determine to what extent vegetation percent cover, patch size, and plant density affect connectivity in an idealized deltaic system. A 2D hydrodynamic model was used to numerically solve the shallow water equations in an idealized channel-island complex, modeled after Wax Lake Delta in Louisiana. For each model run, vegetation patches were distributed randomly throughout the islands according to a specified percent cover and patch size. Vegetation was modeled as a modified bed roughness, which was varied to represent a range of sparse-to-dense vegetation. To determine the effect of heterogeneity, the results of each patchy scenario were compared to results from a uniform run with the same spatially-averaged roughness. It was found that, while all patchy model runs demonstrated more channel-island connectivity than comparable uniform runs, this was particularly true when vegetation patches were dense and covered distributions in the deltaic islands, which can have implications for the fate and transport of sediment/nutrients. These results indicate that the spatial distribution of vegetation can have a notable impact on our ability to model connectivity in deltaic systems.

  3. Research on Connection and Function Reliability of the Oil&Gas Pipeline System

    Directory of Open Access Journals (Sweden)

    Xu Bo

    2017-01-01

    Full Text Available Pipeline transportation is the optimal way for energy delivery in terms of safety, efficiency and environmental protection. Because of the complexity of pipeline external system including geological hazards, social and cultural influence, it is a great challenge to operate the pipeline safely and reliable. Therefore, the pipeline reliability becomes an important issue. Based on the classical reliability theory, the analysis of pipeline system is carried out, then the reliability model of the pipeline system is built, and the calculation is addressed thereafter. Further the connection and function reliability model is applied to a practical active pipeline system, with the use of the proposed methodology of the pipeline system; the connection reliability and function reliability are obtained. This paper firstly presented to considerate the connection and function reliability separately and obtain significant contribution to establish the mathematical reliability model of pipeline system, hence provide fundamental groundwork for the pipeline reliability research in the future.

  4. A Distributed Control Strategy Based on DC Bus Signaling for Modular Photovoltaic Generation Systems With Battery Energy Storage

    DEFF Research Database (Denmark)

    Sun, Kai; Zhang, Li; Xing, Yan

    2011-01-01

    on improved dc bus signaling is proposed for a modular photovoltaic (PV) generation system with battery energy storage elements. In this paper, the modular PV generation system is composed of three modular dc/dc converters for PV arrays, two grid-connected dc/ac converters, and one dc/dc converter for battery......, grid-connected inversion, and islanding with constant voltage (CV) generation.The power balance of the system under extreme conditions such as the islanding operation with a full-charged battery is taken into account in this control strategy. The dc bus voltage level is employed as an information......Modular generation system, which consists of modular power conditioning converters, is an effective solution to integrate renewable energy sources with conventional utility grid to improve reliability and efficiency, especially for photovoltaic generation. A distributed control strategy based...

  5. Hidden Connectivity in Networks with Vulnerable Classes of Nodes

    Directory of Open Access Journals (Sweden)

    Sebastian M. Krause

    2016-10-01

    Full Text Available In many complex systems representable as networks, nodes can be separated into different classes. Often these classes can be linked to a mutually shared vulnerability. Shared vulnerabilities may be due to a shared eavesdropper or correlated failures. In this paper, we show the impact of shared vulnerabilities on robust connectivity and how the heterogeneity of node classes can be exploited to maintain functionality by utilizing multiple paths. Percolation is the field of statistical physics that is generally used to analyze connectivity in complex networks, but in its existing forms, it cannot treat the heterogeneity of multiple vulnerable classes. To analyze the connectivity under these constraints, we describe each class as a color and develop a “color-avoiding” percolation. We present an analytic theory for random networks and a numerical algorithm for all networks, with which we can determine which nodes are color-avoiding connected and whether the maximal set percolates in the system. We find that the interaction of topology and color distribution implies a rich critical behavior, with critical values and critical exponents depending both on the topology and on the color distribution. Applying our physics-based theory to the Internet, we show how color-avoiding percolation can be used as the basis for new topologically aware secure communication protocols. Beyond applications to cybersecurity, our framework reveals a new layer of hidden structure in a wide range of natural and technological systems.

  6. Hysteresis, phase transitions, and dangerous transients in electrical power distribution systems.

    Science.gov (United States)

    Duclut, Charlie; Backhaus, Scott; Chertkov, Michael

    2013-06-01

    The majority of dynamical studies in power systems focus on the high-voltage transmission grids where models consider large generators interacting with crude aggregations of individual small loads. However, new phenomena have been observed indicating that the spatial distribution of collective, nonlinear contribution of these small loads in the low-voltage distribution grid is crucial to the outcome of these dynamical transients. To elucidate the phenomenon, we study the dynamics of voltage and power flows in a spatially extended distribution feeder (circuit) connecting many asynchronous induction motors and discover that this relatively simple 1+1 (space+time) dimensional system exhibits a plethora of nontrivial spatiotemporal effects, some of which may be dangerous for power system stability. Long-range motor-motor interactions mediated by circuit voltage and electrical power flows result in coexistence and segregation of spatially extended phases defined by individual motor states, a "normal" state where the motors' mechanical (rotation) frequency is slightly smaller than the nominal frequency of the basic ac flows and a "stalled" state where the mechanical frequency is small. Transitions between the two states can be initiated by a perturbation of the voltage or base frequency at the head of the distribution feeder. Such behavior is typical of first-order phase transitions in physics, and this 1+1 dimensional model shows many other properties of a first-order phase transition with the spatial distribution of the motors' mechanical frequency playing the role of the order parameter. In particular, we observe (a) propagation of the phase-transition front with the constant speed (in very long feeders) and (b) hysteresis in transitions between the normal and stalled (or partially stalled) phases.

  7. Industry consultation on grid connection of small PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Knight, J.; Thorneycroft, J.; Cotterell, M.; Gambro, S.

    2000-07-01

    This report presents the results of consultation within the PV industry and the electricity supply industry concerning guidelines for the connection of small PV systems to the electricity network. (author)

  8. Security credentials management system (SCMS) design and analysis for the connected vehicle system : draft.

    Science.gov (United States)

    2013-12-27

    This report presents an analysis by Booz Allen Hamilton (Booz Allen) of the technical design for the Security Credentials Management System (SCMS) intended to support communications security for the connected vehicle system. The SCMS technical design...

  9. The PWM strategies of grid-connected distributed generation active NPC inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Xinmin, Jin; Kerekes, Tamas

    2009-01-01

    The Neutral Point Clamped topology due to high efficiency, low leakage current and EMI, its integration is widely used in the distributed generation (DG) systems. However the main disadvantage of the NPC inverter is given by an unequal distribution of the losses in the semiconductor devices, which...... leads to an unequal distribution of temperature. By using the Active NPC topology, the power losses distribution problem is alleviated. The modulation strategy is a key issue for losses distribution in this topology. In this paper two known strategies are discussed and a new proposed PWM strategy......, namely the Adjustable Losses Distribution (ALD) PWM strategy is proposed for better losses distribution in the Active NPC (ANPC) topology. Simulations using Simulink and the PLECS toolbox have been done for evaluating efficiency of different NPC topologies and some experimental results are presented...

  10. How to secure the connection between thoracostomy tube and drainage system?

    Science.gov (United States)

    Li, Ka Ki Pat; Wong, Kit Shing John; Wong, Yau Hang Henry; Cheng, Ka Lok; So, Fung Ling; Lau, Chu Leung; Kam, Chak Wah

    2014-01-01

    Thoracostomy tube insertion is one of the common bedside procedures in emergency medicine and many acute specialties. Dislodgement of thoracostomy tube from the connection tube of chest drainage system is an important problem with potential complications such as contamination, infection and pneumothorax. Besides, mere loosening can also lead to malfunction. It is a common practice to tape the connection of the system. This study aimed to evaluate the materials and methods of connection of chest drain system to minimize drainage dislodgement. We conducted an experimental study to assess the tightness of the connection with various taping materials and methods. We selected three commonly used adhesive materials (3M™ Transpore™ Medical tape, 3M™ Micropore™ Medical tape, 3M™ Soft Cloth Tape on Liner) and three different methods (cross method, straight method, nylon band) to secure the junction between the thoracostomy tube and the bi-conical adaptor in the drainage system. The measured outcome was the weight causing visible loosening of the junction between thoracotomy tube and the adaptor. For each taping material and taping method, 10 trials were performed. The median weight required to disconnect the junction is 26.22 lb for Transpore™, 31.29 lb for Micropore™ and 32.44 lb for Soft Cloth Tape on Liner. A smaller force was required to disconnect if Transpore™ is used (Ptube to the chest drainage system. Transpore™ is not a recommended material for thoracostomy tube taping.

  11. Motor imagery learning modulates functional connectivity of multiple brain systems in resting state.

    Science.gov (United States)

    Zhang, Hang; Long, Zhiying; Ge, Ruiyang; Xu, Lele; Jin, Zhen; Yao, Li; Liu, Yijun

    2014-01-01

    Learning motor skills involves subsequent modulation of resting-state functional connectivity in the sensory-motor system. This idea was mostly derived from the investigations on motor execution learning which mainly recruits the processing of sensory-motor information. Behavioral evidences demonstrated that motor skills in our daily lives could be learned through imagery procedures. However, it remains unclear whether the modulation of resting-state functional connectivity also exists in the sensory-motor system after motor imagery learning. We performed a fMRI investigation on motor imagery learning from resting state. Based on previous studies, we identified eight sensory and cognitive resting-state networks (RSNs) corresponding to the brain systems and further explored the functional connectivity of these RSNs through the assessments, connectivity and network strengths before and after the two-week consecutive learning. Two intriguing results were revealed: (1) The sensory RSNs, specifically sensory-motor and lateral visual networks exhibited greater connectivity strengths in precuneus and fusiform gyrus after learning; (2) Decreased network strength induced by learning was proved in the default mode network, a cognitive RSN. These results indicated that resting-state functional connectivity could be modulated by motor imagery learning in multiple brain systems, and such modulation displayed in the sensory-motor, visual and default brain systems may be associated with the establishment of motor schema and the regulation of introspective thought. These findings further revealed the neural substrates underlying motor skill learning and potentially provided new insights into the therapeutic benefits of motor imagery learning.

  12. Repetitive controller for improving grid-connected photovoltaic systems

    NARCIS (Netherlands)

    Almeida, de P.M.; Duarte, J.L.; Ribeiro, P.F.; Barbosa, P.G.

    2014-01-01

    This study presents the modelling and design steps of a discrete time recursive repetitive controller (RC) to be used in a grid-connected photovoltaic (PV) system. It is shown that the linear synchronous reference frame proportional-integral controller, originally designed to control the converter's

  13. Distributed Robotics Education

    DEFF Research Database (Denmark)

    Lund, Henrik Hautop; Pagliarini, Luigi

    2011-01-01

    Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept of a distribu......Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept...... to be changed, related to multirobot control and human-robot interaction control from virtual to physical representation. The proposed system is valuable for bringing a vast number of issues into education – such as parallel programming, distribution, communication protocols, master dependency, connectivity...

  14. Influence of parafunctional loading and prosthetic connection on stress distribution: a 3D finite element analysis.

    Science.gov (United States)

    Torcato, Leonardo Bueno; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos; Falcón-Antenucci, Rosse Mary; Santiago Júnior, Joel Ferreira; de Faria Almeida, Daniel Augusto

    2015-11-01

    Clinicians should consider parafunctional occlusal load when planning treatment. Prosthetic connections can reduce the stress distribution on an implant-supported prosthesis. The purpose of this 3-dimensional finite element study was to assess the influence of parafunctional loading and prosthetic connections on stress distribution. Computer-aided design software was used to construct 3 models. Each model was composed of a bone and an implant (external hexagon, internal hexagon, or Morse taper) with a crown. Finite element analysis software was used to generate the finite element mesh and establish the loading and boundary conditions. A normal force (200-N axial load and 100-N oblique load) and parafunctional force (1000-N axial and 500-N oblique load) were applied. Results were visualized as the maximum principal stress. Three-way analysis of variance and Tukey test were performed, and the percentage of contribution of each variable to the stress concentration was calculated from sum-of squares-analysis. Stress was concentrated around the implant at the cortical bone, and models with the external hexagonal implant showed the highest stresses (PProsthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Control scheme towards enhancing power quality and operational efficiency of single-phase two-stage grid-connected photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Mahmoud Salem

    2015-12-01

    Full Text Available Achieving high reliable grid-connected photovoltaic (PV systems with high power quality and high operation efficiency is highly required for distributed generation units. A double grid-frequency voltage ripple is found on the dc-link voltage in single-phase photovoltaic grid-connected systems due to the unbalance of the instantaneous dc input and ac output powers. This voltage ripple has undesirable effects on the power quality and operational efficiency of the whole system. Harmonic distortion in the injected current to the grid is one of the problems caused by this double grid-frequency voltage ripple. The double grid frequency ripple propagates to the PV voltage and current which disturb the extracted maximum power from the PV array. This paper introduces intelligent solutions towards mitigate the side effects of the double grid-frequency voltage ripple on the transferred power quality and the operational efficiency of single-phase two-stage grid-connected PV system. The proposed system has three control loops: MPPT control loop, dc-link voltage control loop and inverter current control loop. Solutions are introduced for all the three control loops in the system. The current controller cancels the dc-link voltage effect on the total harmonic distortion of the output current. The dc-link voltage controller is designed to generate a ripple free reference current signal that leads to enhance the quality of the output power. Also a modified MPPT controller is proposed to optimize the extracted power from the PV array. Simulation results show that higher injected power quality is achieved and higher efficiency of the overall system is realized.

  16. Symmetry of interactions rules in incompletely connected random replicator ecosystems.

    Science.gov (United States)

    Kärenlampi, Petri P

    2014-06-01

    The evolution of an incompletely connected system of species with speciation and extinction is investigated in terms of random replicators. It is found that evolving random replicator systems with speciation do become large and complex, depending on speciation parameters. Antisymmetric interactions result in large systems, whereas systems with symmetric interactions remain small. A co-dominating feature is within-species interaction pressure: large within-species interaction increases species diversity. Average fitness evolves in all systems, however symmetry and connectivity evolve in small systems only. Newcomers get extinct almost immediately in symmetric systems. The distribution in species lifetimes is determined for antisymmetric systems. The replicator systems investigated do not show any sign of self-organized criticality. The generalized Lotka-Volterra system is shown to be a tedious way of implementing the replicator system.

  17. An overview of the EOSDIS V0 information management system: Lessons learned from the implementation of a distributed data system

    Science.gov (United States)

    Ryan, Patrick M.

    1994-01-01

    The EOSDIS Version 0 system, released in July, 1994, is a working prototype of a distributed data system. One of the purposes of the V0 project is to take several existing data systems and coordinate them into one system while maintaining the independent nature of the original systems. The project is a learning experience and the lessons are being passed on to the architects of the system which will distribute the data received from the planned EOS satellites. In the V0 system, the data resides on heterogeneous systems across the globe but users are presented with a single, integrated interface. This interface allows users to query the participating data centers based on a wide set of criteria. Because this system is a prototype, we used many novel approaches in trying to connect a diverse group of users with the huge amount of available data. Some of these methods worked and others did not. Now that V0 has been released to the public, we can look back at the design and implementation of the system and also consider some possible future directions for the next generation of EOSDIS.

  18. Distributed systems status and control

    Science.gov (United States)

    Kreidler, David; Vickers, David

    1990-01-01

    Concepts are investigated for an automated status and control system for a distributed processing environment. System characteristics, data requirements for health assessment, data acquisition methods, system diagnosis methods and control methods were investigated in an attempt to determine the high-level requirements for a system which can be used to assess the health of a distributed processing system and implement control procedures to maintain an accepted level of health for the system. A potential concept for automated status and control includes the use of expert system techniques to assess the health of the system, detect and diagnose faults, and initiate or recommend actions to correct the faults. Therefore, this research included the investigation of methods by which expert systems were developed for real-time environments and distributed systems. The focus is on the features required by real-time expert systems and the tools available to develop real-time expert systems.

  19. Active and reactive power neurocontroller for grid-connected photovoltaic generation system

    Directory of Open Access Journals (Sweden)

    I. Abadlia

    2016-03-01

    Full Text Available Many researchers have contributed to the development of a firm foundation for analysis and design of control applications in grid-connected renewable energy sources. This paper presents an intelligent control algorithm fond on artificial neural networks for active and reactive power controller in grid-connected photovoltaic generation system. The system is devices into two parts in which each part contains an inverter with control algorithm. A DC/DC converter in output voltage established by control magnitude besides maximum power point tracker algorithm always finds optimal power of the PV array in use. A DC/AC hysteresis inverter designed can synchronize a sinusoidal current output with the grid voltage and accurate an independent active and reactive power control. Simulation results confirm the validation of the purpose. Neurocontroller based active and reactive power presents an efficiency control that guarantees good response to the steps changing in active and reactive power with an acceptable current/voltage synchronism. In this paper the power circuit and the control system of the presented grid-connected photovoltaic generation system is simulated and tested by MatLab/Simulink.

  20. Multicriterion problem of allocation of resources in the heterogeneous distributed information processing systems

    Science.gov (United States)

    Antamoshkin, O. A.; Kilochitskaya, T. R.; Ontuzheva, G. A.; Stupina, A. A.; Tynchenko, V. S.

    2018-05-01

    This study reviews the problem of allocation of resources in the heterogeneous distributed information processing systems, which may be formalized in the form of a multicriterion multi-index problem with the linear constraints of the transport type. The algorithms for solution of this problem suggest a search for the entire set of Pareto-optimal solutions. For some classes of hierarchical systems, it is possible to significantly speed up the procedure of verification of a system of linear algebraic inequalities for consistency due to the reducibility of them to the stream models or the application of other solution schemes (for strongly connected structures) that take into account the specifics of the hierarchies under consideration.

  1. Improvement of Protection Coordination for a Distribution System Connected to a Microgrid using Unidirectional Fault Current Limiter

    Directory of Open Access Journals (Sweden)

    Mazen Abdel-Salam

    2017-09-01

    Full Text Available The presence of distributed generation (DG units in distribution systems increases the fault current level, which disrupts the existing coordination time interval of the protective overcurrent relays. One of the ways for decreasing DG effects on the coordination of protective devices is re-coordination of the relays by installing unidirectional fault current limiter (UFCL between the main grid (upstream network and the microgrid (downstream network. The UFCL does not limit fault current contribution of the upstream network when fault occurs in downstream but limits fault current contribution of the downstream network when fault occurs in the upstream. Moreover, it preserves the coordination between all of the relays. Several case studies are carried out for illustrating the performance of the UFCL in maintaining the relay coordination.

  2. Performance of Grid-Connected Photovoltaic System in Two Sites in Kuwait

    Directory of Open Access Journals (Sweden)

    Ali Hajiah

    2012-01-01

    Full Text Available This paper presents an assessment of the electricity generated by photovoltaic (PV grid-connected systems in Kuwait. Three years of meteorological data are provided for two main sites in Kuwait, namely, Al-Wafra and Mutla. These data and a PV grid-connected system mathematical model are used to assist a 100 kWp grid-connected PV system proposed for both sites. The proposed systems show high energy productivity whereas the annual capacity factors for Mutla and Al-Wafra are 22.25% and 21.6%, respectively. Meanwhile the annual yield factors for Mutla and Al-Wafra are 1861 kWh/kWp/year and 1922.7 kWh/kWp/year, respectively. On the other hand the cost of the energy generated by both systems is about 0.1 USD/kWh which is very close to the price of the energy sold by the Ministry of Electricity and Water (MEW. Furthermore the invested money is recovered during the assumed life cycle time whereas the payback period for both sites is about 15 years. This work contains worthwhile technical information for those who are interested in PV technology investment in Kuwait.

  3. Developmental Changes in Brain Network Hub Connectivity in Late Adolescence.

    Science.gov (United States)

    Baker, Simon T E; Lubman, Dan I; Yücel, Murat; Allen, Nicholas B; Whittle, Sarah; Fulcher, Ben D; Zalesky, Andrew; Fornito, Alex

    2015-06-17

    The human brain undergoes substantial development throughout adolescence and into early adulthood. This maturational process is thought to include the refinement of connectivity between putative connectivity hub regions of the brain, which collectively form a dense core that enhances the functional integration of anatomically distributed, and functionally specialized, neural systems. Here, we used longitudinal diffusion magnetic resonance imaging to characterize changes in connectivity between 80 cortical and subcortical anatomical regions over a 2 year period in 31 adolescents between the ages of 15 and 19 years. Connectome-wide analysis indicated that only a small subset of connections showed evidence of statistically significant developmental change over the study period, with 8% and 6% of connections demonstrating decreased and increased structural connectivity, respectively. Nonetheless, these connections linked 93% and 90% of the 80 regions, respectively, pointing to a selective, yet anatomically distributed pattern of developmental changes that involves most of the brain. Hub regions showed a distinct tendency to be highly connected to each other, indicating robust "rich-club" organization. Moreover, connectivity between hubs was disproportionately influenced by development, such that connectivity between subcortical hubs decreased over time, whereas frontal-subcortical and frontal-parietal hub-hub connectivity increased over time. These findings suggest that late adolescence is characterized by selective, yet significant remodeling of hub-hub connectivity, with the topological organization of hubs shifting emphasis from subcortical hubs in favor of an increasingly prominent role for frontal hub regions. Copyright © 2015 the authors 0270-6474/15/359078-10$15.00/0.

  4. Optimal Placement and Sizing of Fault Current Limiters in Distributed Generation Systems Using a Hybrid Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    N. Bayati

    2017-02-01

    Full Text Available Distributed Generation (DG connection in a power system tends to increase the short circuit level in the entire system which, in turn, could eliminate the protection coordination between the existing relays. Fault Current Limiters (FCLs are often used to reduce the short-circuit level of the network to a desirable level, provided that they are dully placed and appropriately sized. In this paper, a method is proposed for optimal placement of FCLs and optimal determination of their impedance values by which the relay operation time, the number and size of the FCL are minimized while maintaining the relay coordination before and after DG connection. The proposed method adopts the removal of low-impact FCLs and uses a hybrid Genetic Algorithm (GA optimization scheme to determine the optimal placement of FCLs and the values of their impedances. The suitability of the proposed method is demonstrated by examining the results of relay coordination in a typical DG network before and after DG connection.

  5. Monte Carlo Simulations of Phosphate Polyhedron Connectivity in Glasses

    Energy Technology Data Exchange (ETDEWEB)

    ALAM,TODD M.

    1999-12-21

    Monte Carlo simulations of phosphate tetrahedron connectivity distributions in alkali and alkaline earth phosphate glasses are reported. By utilizing a discrete bond model, the distribution of next-nearest neighbor connectivities between phosphate polyhedron for random, alternating and clustering bonding scenarios was evaluated as a function of the relative bond energy difference. The simulated distributions are compared to experimentally observed connectivities reported for solid-state two-dimensional exchange and double-quantum NMR experiments of phosphate glasses. These Monte Carlo simulations demonstrate that the polyhedron connectivity is best described by a random distribution in lithium phosphate and calcium phosphate glasses.

  6. Distributed Treatment Systems.

    Science.gov (United States)

    Zgonc, David; Plante, Luke

    2017-10-01

    This section presents a review of the literature published in 2016 on topics relating to distributed treatment systems. This review is divided into the following sections with multiple subsections under each: constituent removal; treatment technologies; and planning and treatment system management.

  7. Performance of a grid connected PV system used as active filter

    International Nuclear Information System (INIS)

    Calleja, Hugo; Jimenez, Humberto

    2004-01-01

    In this paper, the performance of a grid connected photovoltaic (PV) system used as an active filter is presented. Its main feature is the capability to compensate the reactive and harmonic currents drawn by nonlinear loads while simultaneously injecting into the grid the maximum power available from the cells. The system can also operate as a stand alone active filter. The system was connected to a 1 kW PV array and tested with the loads typically found in households: small motors, personal computers and electronic ballasts. The results show that the system can correct the power factor to values close to unity for all the cases tested, thereby improving the efficiency of the electric energy supply

  8. Distributed Operations Planning

    Science.gov (United States)

    Fox, Jason; Norris, Jeffrey; Powell, Mark; Rabe, Kenneth; Shams, Khawaja

    2007-01-01

    Maestro software provides a secure and distributed mission planning system for long-term missions in general, and the Mars Exploration Rover Mission (MER) specifically. Maestro, the successor to the Science Activity Planner, has a heavy emphasis on portability and distributed operations, and requires no data replication or expensive hardware, instead relying on a set of services functioning on JPL institutional servers. Maestro works on most current computers with network connections, including laptops. When browsing down-link data from a spacecraft, Maestro functions similarly to being on a Web browser. After authenticating the user, it connects to a database server to query an index of data products. It then contacts a Web server to download and display the actual data products. The software also includes collaboration support based upon a highly reliable messaging system. Modifications made to targets in one instance are quickly and securely transmitted to other instances of Maestro. The back end that has been developed for Maestro could benefit many future missions by reducing the cost of centralized operations system architecture.

  9. Level of Service Considerations in Connection with Capacity Adjustment by ITS Systems

    DEFF Research Database (Denmark)

    Jensen, Peder; Andersen, Claus Lund

    1998-01-01

    The paper explores the level of service definition in connection with urban traffic and ITS systems. In addition a new definition is suggested to account for problems encountered with the traditional definition.......The paper explores the level of service definition in connection with urban traffic and ITS systems. In addition a new definition is suggested to account for problems encountered with the traditional definition....

  10. Comparative Analysis of Inversors for Small PV Systems Grid Connected

    International Nuclear Information System (INIS)

    Sidrach de Cardona, M.; Ramirez, L.

    2001-01-01

    The energy produced by a grid connected photovoltaic system is a function of weather conditions, mainly available radiation and temperature, photovoltaic array efficiency and inverter characteristics. The results obtained in experimental measurements with four small grid-connected inverters are described in this work. The main goal is to know the inverter performance in real operation conditions. For this purpose a 2 kW photovoltaic system has been used. These results allow us to know both the inverter efficiency and its output power quality. The following parameters have been evaluated as a function of output inverter power: efficiency, point of maximum power tracking, intensity and voltage waveform, total harmonic distortion and harmonic values to 31 order, frequency, power factor and reactive power. Other interesting parameters like stand-by energy consumption and daily losses due to the inverter threshold have also been analyzed. The results allow us to know the inverter features as a function of its real work point. In our comparative study it is possible to observe remarkable differences between the inverters; these results show how important it is to have a unique standard for inverters to photovoltaic grid-connected systems. (Author) 10 refs

  11. RELIABILITY ANALYSIS OF POWER DISTRIBUTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    Popescu V.S.

    2012-04-01

    Full Text Available Power distribution systems are basic parts of power systems and reliability of these systems at present is a key issue for power engineering development and requires special attention. Operation of distribution systems is accompanied by a number of factors that produce random data a large number of unplanned interruptions. Research has shown that the predominant factors that have a significant influence on the reliability of distribution systems are: weather conditions (39.7%, defects in equipment(25% and unknown random factors (20.1%. In the article is studied the influence of random behavior and are presented estimations of reliability of predominantly rural electrical distribution systems.

  12. Policy incentives and grid-connected photovoltaics system development in China

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jing; Xu Yugao

    2007-07-01

    China has made considerable progress in solar PV generation technology. However, compared with conventional generation technologies or even other renewables such as wind and biomass, grid-connected PV technology is in its early stage and has not reached an adequate level of economic performance. Therefore, policy incentives will play important roles in attracting more social investments to facilitate the development of grid-connected PV generation. This paper is focused on analyzing the role of incentive policies in enhancing the market competitiveness of grid-connected solar PV systems in the context of China with an economic model and some policy suggestions are given based on simulation modeling efforts. (auth)

  13. Online Monitoring System of Air Distribution in Pulverized Coal-Fired Boiler Based on Numerical Modeling

    Directory of Open Access Journals (Sweden)

    Żymełka Piotr

    2017-12-01

    Full Text Available Balanced distribution of air in coal-fired boiler is one of the most important factors in the combustion process and is strongly connected to the overall system efficiency. Reliable and continuous information about combustion airflow and fuel rate is essential for achieving optimal stoichiometric ratio as well as efficient and safe operation of a boiler. Imbalances in air distribution result in reduced boiler efficiency, increased gas pollutant emission and operating problems, such as corrosion, slagging or fouling. Monitoring of air flow trends in boiler is an effective method for further analysis and can help to appoint important dependences and start optimization actions. Accurate real-time monitoring of the air distribution in boiler can bring economical, environmental and operational benefits. The paper presents a novel concept for online monitoring system of air distribution in coal-fired boiler based on real-time numerical calculations. The proposed mathematical model allows for identification of mass flow rates of secondary air to individual burners and to overfire air (OFA nozzles. Numerical models of air and flue gas system were developed using software for power plant simulation. The correctness of the developed model was verified and validated with the reference measurement values. The presented numerical model for real-time monitoring of air distribution is capable of giving continuous determination of the complete air flows based on available digital communication system (DCS data.

  14. Online Monitoring System of Air Distribution in Pulverized Coal-Fired Boiler Based on Numerical Modeling

    Science.gov (United States)

    Żymełka, Piotr; Nabagło, Daniel; Janda, Tomasz; Madejski, Paweł

    2017-12-01

    Balanced distribution of air in coal-fired boiler is one of the most important factors in the combustion process and is strongly connected to the overall system efficiency. Reliable and continuous information about combustion airflow and fuel rate is essential for achieving optimal stoichiometric ratio as well as efficient and safe operation of a boiler. Imbalances in air distribution result in reduced boiler efficiency, increased gas pollutant emission and operating problems, such as corrosion, slagging or fouling. Monitoring of air flow trends in boiler is an effective method for further analysis and can help to appoint important dependences and start optimization actions. Accurate real-time monitoring of the air distribution in boiler can bring economical, environmental and operational benefits. The paper presents a novel concept for online monitoring system of air distribution in coal-fired boiler based on real-time numerical calculations. The proposed mathematical model allows for identification of mass flow rates of secondary air to individual burners and to overfire air (OFA) nozzles. Numerical models of air and flue gas system were developed using software for power plant simulation. The correctness of the developed model was verified and validated with the reference measurement values. The presented numerical model for real-time monitoring of air distribution is capable of giving continuous determination of the complete air flows based on available digital communication system (DCS) data.

  15. Motor Imagery Learning Modulates Functional Connectivity of Multiple Brain Systems in Resting State

    Science.gov (United States)

    Zhang, Hang; Long, Zhiying; Ge, Ruiyang; Xu, Lele; Jin, Zhen; Yao, Li; Liu, Yijun

    2014-01-01

    Background Learning motor skills involves subsequent modulation of resting-state functional connectivity in the sensory-motor system. This idea was mostly derived from the investigations on motor execution learning which mainly recruits the processing of sensory-motor information. Behavioral evidences demonstrated that motor skills in our daily lives could be learned through imagery procedures. However, it remains unclear whether the modulation of resting-state functional connectivity also exists in the sensory-motor system after motor imagery learning. Methodology/Principal Findings We performed a fMRI investigation on motor imagery learning from resting state. Based on previous studies, we identified eight sensory and cognitive resting-state networks (RSNs) corresponding to the brain systems and further explored the functional connectivity of these RSNs through the assessments, connectivity and network strengths before and after the two-week consecutive learning. Two intriguing results were revealed: (1) The sensory RSNs, specifically sensory-motor and lateral visual networks exhibited greater connectivity strengths in precuneus and fusiform gyrus after learning; (2) Decreased network strength induced by learning was proved in the default mode network, a cognitive RSN. Conclusions/Significance These results indicated that resting-state functional connectivity could be modulated by motor imagery learning in multiple brain systems, and such modulation displayed in the sensory-motor, visual and default brain systems may be associated with the establishment of motor schema and the regulation of introspective thought. These findings further revealed the neural substrates underlying motor skill learning and potentially provided new insights into the therapeutic benefits of motor imagery learning. PMID:24465577

  16. An Efficient Connected Component Labeling Architecture for Embedded Systems

    Directory of Open Access Journals (Sweden)

    Fanny Spagnolo

    2018-03-01

    Full Text Available Connected component analysis is one of the most fundamental steps used in several image processing systems. This technique allows for distinguishing and detecting different objects in images by assigning a unique label to all pixels that refer to the same object. Most of the previous published algorithms have been designed for implementation by software. However, due to the large number of memory accesses and compare, lookup, and control operations when executed on a general-purpose processor, they do not satisfy the speed performance required by the next generation high performance computer vision systems. In this paper, we present the design of a new Connected Component Labeling hardware architecture suitable for high performance heterogeneous image processing of embedded designs. When implemented on a Zynq All Programmable-System on Chip (AP-SOC 7045 chip, the proposed design allows a throughput rate higher of 220 Mpixels/s to be reached using less than 18,000 LUTs and 5000 FFs, dissipating about 620 μJ.

  17. Congestion management in Smart Distribution Network

    NARCIS (Netherlands)

    Haque, A.N.M.M.; Nguyen, P.H.; Kling, W.L.; Bliek, F.W.

    2014-01-01

    The accelerating use of Distributed Energy Resources (DERs) and new forms of loads connected in the Medium Voltage (MV) and Low Voltage (LV) networks are posing a great challenge for the Distribution System Operators (DSOs) in the near future. The bidirectional and uncertain flow of power may result

  18. Quantum correction and ordering parameter for systems connected by a general point canonical transformation

    International Nuclear Information System (INIS)

    Yeon, Kyu Hwang; Hong, Suc Kyoung; Um, Chung In; George, Thomas F.

    2006-01-01

    With quantum operators corresponding to functions of the canonical variables, Schroedinger equations are constructed for systems corresponding to classical systems connected by a general point canonical transformation. Using the operator connecting quantum states between systems before and after the transformation, the quantum correction term and ordering parameter are obtained

  19. Localization, distribution, and connectivity of neuropeptide Y in the human and porcine retinas-A comparative study.

    Science.gov (United States)

    Christiansen, Anders Tolstrup; Kiilgaard, Jens Folke; Klemp, Kristian; Woldbye, David Paul Drucker; Hannibal, Jens

    2018-04-17

    Neuropeptide Y (NPY) is a peptide neurotransmitter abundantly expressed in the mammalian retina. Since its discovery, NPY has been studied in retinas of several species, but detailed characterization of morphology, cell-type, and connectivity has never been conducted in larger mammals including humans and pigs. As the pig due to size and cellular composition is a well-suited animal for retinal research, we chose to compare the endogenous NPY system of the human retina to that of pigs to support future research in this field. In the present study, using immunohistochemistry, confocal microscopy and 3D reconstructions, we found NPY to be expressed in GABAergic and calretinin-immunoreactive (-ir) amacrine cells of both species as well as parvalbumin-ir amacrine cells of humans. Furthermore, we identified at least two different types of medium- to wide-field NPY-ir amacrine cells. Finally, we detected likely synaptic appositions between the NPY-ir amacrine cells and melanopsin- and nonmelanopsin-ir ganglion cells, GABAergic and dopaminergic amacrine cells, rod bipolar cells, and horizontal cells, suggesting that NPY-ir cells play diverse roles in modulation of both image and non-image forming retinal signaling. These findings extend existing knowledge on NPY and NPY-expressing cells in the human and porcine retina showing a high degree of comparability. The extensive distribution and connectivity of NPY-ir cells described in the present study further highlights the potential importance of NPY signaling in retinal function. © 2018 Wiley Periodicals, Inc.

  20. Simple and Low-Cost Wireless Distributed Measurement System

    Directory of Open Access Journals (Sweden)

    Alessandra Flammini

    2007-07-01

    Full Text Available This paper describes the design and realization of a simple and low-cost system for distributed measurements. Traditional handheld digital multimeters have been equipped with a radio-frequency interface in order to implement what the authors call WDMM, the basic block of a wireless multi-probe data logger. New functionalities require very few components and result in a cost increase of less than 10$. In addition, also maintenance has been facilitated since tracking data such as working state or last calibration time are available to the user. Data inquiry can be performed by a purposely designed module that has the same hardware of the WDMM but a different user interface or by a PDA (Personal Digital Assistant or a traditional personal computer thanks to a USB connection. Simple supervisory software has been realized under the LabVIEW graphical programming environment.

  1. Control of Grid Connected Photovoltaic Systems with Microinverters

    DEFF Research Database (Denmark)

    Yahya, Abdelhafid; El Fadil, Hassan; Oulcaid, Mustapha

    2018-01-01

    This paper addresses the problem of controlling grid connected photovoltaic (PV) systems that are driven with microinverters. The systems to be controlled consist of a solar panel, a boost dc–dc converter, a DC link capacitor, a single-phase full-bridge inverter, a filter inductor, and an isolation...... transformer. We seek controllers that are able to simultaneously achieve four control objectives, namely: (i) asymptotic stability of the closed loop control system; (ii) maximum power point tracking (MPPT) of the PV module; (iii) tight regulation of the DC bus voltage; and (iv) unity power factor (PF...

  2. Intermittent Theta-Burst Stimulation of the Lateral Cerebellum Increases Functional Connectivity of the Default Network

    Science.gov (United States)

    Farzan, Faranak; Eldaief, Mark C.; Schmahmann, Jeremy D.; Pascual-Leone, Alvaro

    2014-01-01

    Cerebral cortical intrinsic connectivity networks share topographically arranged functional connectivity with the cerebellum. However, the contribution of cerebellar nodes to distributed network organization and function remains poorly understood. In humans, we applied theta-burst transcranial magnetic stimulation, guided by subject-specific connectivity, to regions of the cerebellum to evaluate the functional relevance of connections between cerebellar and cerebral cortical nodes in different networks. We demonstrate that changing activity in the human lateral cerebellar Crus I/II modulates the cerebral default mode network, whereas vermal lobule VII stimulation influences the cerebral dorsal attention system. These results provide novel insights into the distributed, but anatomically specific, modulatory impact of cerebellar effects on large-scale neural network function. PMID:25186750

  3. A QCQP Approach for OPF in Multiphase Radial Networks with Wye and Delta Connections: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zamzam, Ahmed, S.; Zhaoy, Changhong; Dall' Anesey, Emiliano; Sidiropoulos, Nicholas D.

    2017-06-27

    This paper examines the AC Optimal Power Flow (OPF) problem for multiphase distribution networks featuring renewable energy resources (RESs). We start by outlining a power flow model for radial multiphase systems that accommodates wye-connected and delta-connected RESs and non-controllable energy assets. We then formalize an AC OPF problem that accounts for both types of connections. Similar to various AC OPF renditions, the resultant problem is a non convex quadratically-constrained quadratic program. However, the so-called Feasible Point Pursuit-Successive Convex Approximation algorithm is leveraged to obtain a feasible and yet locally-optimal solution. The merits of the proposed solution approach are demonstrated using two unbalanced multiphase distribution feeders with both wye and delta connections.

  4. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  5. Interharmonics from Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    As the penetration level of grid-connected Photovoltaic (PV) systems increases, the power quality is one of the major concerns for system operators and the demands are becoming even stricter. The impact of interharmonics on the grid has been acknowledged in recent research when considering a large......-scale adoption of PV inverters. However, the origins of interharmonics remain unclear. Thus, this paper performs tests on a commercial PV inverter to explore interharmonic generation and more important investigates the mechanism of interharmonic emission. The investigation reveals that the perturbation...... of the solutions. Simulation results indicate that the constant-voltage MPPT method is the most suitable solution to the mitigation of interharmonics introduced by the MPPT operation, as it avoids the perturbation in the PV voltage during operation....

  6. Operating cost minimization of a radial distribution system in a deregulated electricity market through reconfiguration using NSGA method

    International Nuclear Information System (INIS)

    Chandramohan, S.; Atturulu, Naresh; Devi, R.P. Kumudini; Venkatesh, B.

    2010-01-01

    In the future, mechanisms for trade in ancillary services such as reactive power will be implemented in many deregulated power systems. In such an operating framework, a Distribution Corporation (DisCo) would have to purchase reactive power along with real power from the connected transmission corporation. A DisCo would want to minimize its operating costs by minimizing the total amount of real and reactive power drawn from the connected transmission system. Optimally reconfiguring the network will achieve such a goal. In this work, we use a non-dominated sorting genetic algorithm (NSGA) for reconfiguring a radial DisCo to minimize its operating costs considering real and reactive power costs while maximizing its operating reliability and satisfying the regular operating constraints. This method is tested on sample test systems and reported. (author)

  7. Distributed optimal coordination for distributed energy resources in power systems

    DEFF Research Database (Denmark)

    Wu, Di; Yang, Tao; Stoorvogel, A.

    2017-01-01

    Driven by smart grid technologies, distributed energy resources (DERs) have been rapidly developing in recent years for improving reliability and efficiency of distribution systems. Emerging DERs require effective and efficient coordination in order to reap their potential benefits. In this paper......, we consider an optimal DER coordination problem over multiple time periods subject to constraints at both system and device levels. Fully distributed algorithms are proposed to dynamically and automatically coordinate distributed generators with multiple/single storages. With the proposed algorithms...

  8. Functional requirements for an intelligent RPC. [remote power controller for spaceborne electrical distribution system

    Science.gov (United States)

    Aucoin, B. M.; Heller, R. P.

    1990-01-01

    An intelligent remote power controller (RPC) based on microcomputer technology can implement advanced functions for the accurate and secure detection of all types of faults on a spaceborne electrical distribution system. The intelligent RPC will implement conventional protection functions such as overcurrent, under-voltage, and ground fault protection. Advanced functions for the detection of soft faults, which cannot presently be detected, can also be implemented. Adaptive overcurrent protection changes overcurrent settings based on connected load. Incipient and high-impedance fault detection provides early detection of arcing conditions to prevent fires, and to clear and reconfigure circuits before soft faults progress to a hard-fault condition. Power electronics techniques can be used to implement fault current limiting to prevent voltage dips during hard faults. It is concluded that these techniques will enhance the overall safety and reliability of the distribution system.

  9. Distributed system for parallel data processing of ECT signals for electromagnetic flaw detection in materials

    International Nuclear Information System (INIS)

    Guliashki, Vassil; Marinova, Galia

    2002-01-01

    The paper proposes a distributed system for parallel data processing of ECT signals for flaw detection in materials. The measured data are stored in files on a host computer, where a JAVA server is located. The host computer is connected through Internet to a set of client computers, distributed geographically. The data are distributed from the host computer by means of the JAVA server to the client computers according their requests. The software necessary for the data processing is installed on each client computer in advance. The organization of the data processing on many computers, working simultaneously in parallel, leads to great time reducing, especially in cases when huge amount of data should be processed in very short time. (Author)

  10. Cognitive Connected Vehicle Information System Design Requirement for Safety: Role of Bayesian Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    Ata Khan

    2013-04-01

    Full Text Available Intelligent transportation systems (ITS are gaining acceptance around the world and the connected vehicle component of ITS is recognized as a high priority research and development area in many technologically advanced countries. Connected vehicles are expected to have the capability of safe, efficient and eco-driving operations whether these are under human control or in the adaptive machine control mode of operations. The race is on to design the capability to operate in connected traffic environment. The operational requirements can be met with cognitive vehicle design features made possible by advances in artificial intelligence-supported methodology, improved understanding of human factors, and advances in communication technology. This paper describes cognitive features and their information system requirements. The architecture of an information system is presented that supports the features of the cognitive connected vehicle. For better focus, information processing capabilities are specified and the role of Bayesian artificial intelligence is defined for data fusion. Example applications illustrate the role of information systems in integrating intelligent technology, Bayesian artificial intelligence, and abstracted human factors. Concluding remarks highlight the role of the information system and Bayesian artificial intelligence in the design of a new generation of cognitive connected vehicle.

  11. Multiple effects of hydrological connectivity on floodplain processes in human modified river systems

    Science.gov (United States)

    Hein, Thomas; Bondar-Kunze, Elisabeth; Preiner, Stefan; Reckendorfer, Walter; Tritthart, Michael; Weigelhofer, Gabriele; Welti, Nina

    2014-05-01

    Floodplain and riparian ecosystems provide multiple functions and services of importance for human well-being and are of strategic importance for different sectors at catchment scale. Especially floodplains in the vicinity of urban areas can be areas of conflicting interests ranging from different land use types, flood water retention, drinking water production and recreation to conservation of last remnants of former riverine landscape, as it is the case in floodplains in the Danube Nationalpark downstream Vienna. Many of these ecosystem functions and services are controlled by the exchange conditions between river main channel and floodplain systems, the hydrological connectivity. At the same time these systems have been highly altered and especially the connectivity has been severely impaired. Thus, far ranging effects of changes in hydrological connectivity at various levels can be expected in altered floodplain systems. The aim of this presentation is to explore the complex control of different ecosystem functions and associated services by different parameters of hydrological connectivity, ranging from nutrient, sediment and matter dynamics and biodiversity aspects. Increasing connectivity will be shown to impact microbial dynamics, sediment-water interactions, carbon dynamics and trophic conditions, thus affecting the fundamental functions of particular floodplain systems at various spatial and temporal scales. Based on these changes also the provision of ecosystem services of floodplains is affected. The results clearly show that hydrological connectivity needs to be considered in a sustainable management approach.

  12. Research in Distributed Real-Time Systems

    Science.gov (United States)

    Mukkamala, R.

    1997-01-01

    This document summarizes the progress we have made on our study of issues concerning the schedulability of real-time systems. Our study has produced several results in the scalability issues of distributed real-time systems. In particular, we have used our techniques to resolve schedulability issues in distributed systems with end-to-end requirements. During the next year (1997-98), we propose to extend the current work to address the modeling and workload characterization issues in distributed real-time systems. In particular, we propose to investigate the effect of different workload models and component models on the design and the subsequent performance of distributed real-time systems.

  13. Restoration of lost connectivity of partitioned wireless sensor networks

    Directory of Open Access Journals (Sweden)

    Virender Ranga

    2016-05-01

    Full Text Available The lost connectivity due to failure of large scale nodes plays major role to degrade the system performance by generating unnecessary overhead or sometimes totally collapse the active network. There are many issues and challenges to restore the lost connectivity in an unattended scenario, i.e. how many recovery nodes will be sufficient and on which locations these recovery nodes have to be placed. A very few centralized and distributed approaches have been proposed till now. The centralized approaches are good for a scenario where information about the disjoint network, i.e. number of disjoint segments and their locations are well known in advance. However, for a scenario where such information is unknown due to the unattended harsh environment, a distributed approach is a better solution to restore the partitioned network. In this paper, we have proposed and implemented a semi-distributed approach called Relay node Placement using Fermat Point (RPFP. The proposed approach is capable of restoring lost connectivity with small number of recovery relay nodes and it works for any number of disjoint segments. The simulation experiment results show effectiveness of our approach as compared to existing benchmark approaches.

  14. Elastin Cables Define the Axial Connective Tissue System in the Murine Lung.

    Science.gov (United States)

    Wagner, Willi; Bennett, Robert D; Ackermann, Maximilian; Ysasi, Alexandra B; Belle, Janeil; Valenzuela, Cristian D; Pabst, Andreas; Tsuda, Akira; Konerding, Moritz A; Mentzer, Steven J

    2015-11-01

    The axial connective tissue system is a fiber continuum of the lung that maintains alveolar surface area during changes in lung volume. Although the molecular anatomy of the axial system remains undefined, the fiber continuum of the lung is central to contemporary models of lung micromechanics and alveolar regeneration. To provide a detailed molecular structure of the axial connective tissue system, we examined the extracellular matrix of murine lungs. The lungs were decellularized using a 24 hr detergent treatment protocol. Systematic evaluation of the decellularized lungs demonstrated no residual cellular debris; morphometry demonstrated a mean 39 ± 7% reduction in lung dimensions. Scanning electron microscopy (SEM) demonstrated an intact structural hierarchy within the decellularized lung. Light, fluorescence, and SEM of precision-cut lung slices demonstrated that alveolar duct structure was defined by a cable line element encased in basement membrane. The cable line element arose in the distal airways, passed through septal tips and inserted into neighboring blood vessels and visceral pleura. The ropelike appearance, collagenase resistance and anti-elastin immunostaining indicated that the cable was an elastin macromolecule. Our results indicate that the helical line element of the axial connective tissue system is composed of an elastin cable that not only defines the structure of the alveolar duct, but also integrates the axial connective tissue system into visceral pleura and peripheral blood vessels. © 2015 Wiley Periodicals, Inc.

  15. The DIAS/CEOS Water Portal, distributed system using brokering architecture

    Science.gov (United States)

    Miura, Satoko; Sekioka, Shinichi; Kuroiwa, Kaori; Kudo, Yoshiyuki

    2015-04-01

    The DIAS/CEOS Water Portal is a one of the DIAS (Data Integration and Analysis System, http://www.editoria.u-tokyo.ac.jp/projects/dias/?locale=en_US) systems for data distribution for users including, but not limited to, scientists, decision makers and officers like river administrators. This portal has two main functions; one is to search and access data and the other is to register and share use cases which use datasets provided via this portal. This presentation focuses on the first function, to search and access data. The Portal system is distributed in the sense that, while the portal system is located in Tokyo, the data is located in archive centers which are globally distributed. For example, some in-situ data is archived at the National Center for Atmospheric Research (NCAR) Earth Observing Laboratory in Boulder, Colorado, USA. The NWP station time series and global gridded model output data is archived at the Max Planck Institute for Meteorology (MPIM) in cooperation with the World Data Center for Climate in Hamburg, Germany. Part of satellite data is archived at DIAS storage at the University of Tokyo, Japan. This portal itself does not store data. Instead, according to requests made by users on the web page, it retrieves data from distributed data centers on-the-fly and lets them download and see rendered images/plots. Although some data centers have unique meta data format and/or data search protocols, our portal's brokering function enables users to search across various data centers at one time, like one-stop shopping. And this portal is also connected to other data brokering systems, including GEOSS DAB (Discovery and Access Broker). As a result, users can search over thousands of datasets, millions of files at one time. Our system mainly relies on the open source software GI-cat (http://essi-lab.eu/do/view/GIcat), Opensearch protocol and OPeNDAP protocol to enable the above functions. Details on how it works will be introduced during the

  16. Interconnecting PV on New York City's Secondary Network Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, K; Coddington, M; Burman, K; Hayter, S; Kroposki, B; Watson, and A

    2009-11-01

    The U.S. Department of Energy (DOE) has teamed with cities across the country through the Solar America Cities (SAC) partnership program to help reduce barriers and accelerate implementation of solar energy. The New York City SAC team is a partnership between the City University of New York (CUNY), the New York City Mayor s Office of Long-term Planning and Sustainability, and the New York City Economic Development Corporation (NYCEDC).The New York City SAC team is working with DOE s National Renewable Energy Laboratory (NREL) and Con Edison, the local utility, to develop a roadmap for photovoltaic (PV) installations in the five boroughs. The city set a goal to increase its installed PV capacity from1.1 MW in 2005 to 8.1 MW by 2015 (the maximum allowed in 2005). A key barrier to reaching this goal, however, is the complexity of the interconnection process with the local utility. Unique challenges are associated with connecting distributed PV systems to secondary network distribution systems (simplified to networks in this report). Although most areas of the country use simpler radial distribution systems to distribute electricity, larger metropolitan areas like New York City typically use networks to increase reliability in large load centers. Unlike the radial distribution system, where each customer receives power through a single line, a network uses a grid of interconnected lines to deliver power to each customer through several parallel circuits and sources. This redundancy improves reliability, but it also requires more complicated coordination and protection schemes that can be disrupted by energy exported from distributed PV systems. Currently, Con Edison studies each potential PV system in New York City to evaluate the system s impact on the network, but this is time consuming for utility engineers and may delay the customer s project or add cost for larger installations. City leaders would like to streamline this process to facilitate faster, simpler, and

  17. Model for teaching distributed computing in a distance-based educational environment

    CSIR Research Space (South Africa)

    le Roux, P

    2010-10-01

    Full Text Available Due to the prolific growth in connectivity, the development and implementation of distributed systems receives a lot of attention. Several technologies and languages exist for the development and implementation of such distributed systems; however...

  18. A Distribution-class Locational Marginal Price (DLMP) Index for Enhanced Distribution Systems

    Science.gov (United States)

    Akinbode, Oluwaseyi Wemimo

    The smart grid initiative is the impetus behind changes that are expected to culminate into an enhanced distribution system with the communication and control infrastructure to support advanced distribution system applications and resources such as distributed generation, energy storage systems, and price responsive loads. This research proposes a distribution-class analog of the transmission LMP (DLMP) as an enabler of the advanced applications of the enhanced distribution system. The DLMP is envisioned as a control signal that can incentivize distribution system resources to behave optimally in a manner that benefits economic efficiency and system reliability and that can optimally couple the transmission and the distribution systems. The DLMP is calculated from a two-stage optimization problem; a transmission system OPF and a distribution system OPF. An iterative framework that ensures accurate representation of the distribution system's price sensitive resources for the transmission system problem and vice versa is developed and its convergence problem is discussed. As part of the DLMP calculation framework, a DCOPF formulation that endogenously captures the effect of real power losses is discussed. The formulation uses piecewise linear functions to approximate losses. This thesis explores, with theoretical proofs, the breakdown of the loss approximation technique when non-positive DLMPs/LMPs occur and discusses a mixed integer linear programming formulation that corrects the breakdown. The DLMP is numerically illustrated in traditional and enhanced distribution systems and its superiority to contemporary pricing mechanisms is demonstrated using price responsive loads. Results show that the impact of the inaccuracy of contemporary pricing schemes becomes significant as flexible resources increase. At high elasticity, aggregate load consumption deviated from the optimal consumption by up to about 45 percent when using a flat or time-of-use rate. Individual load

  19. Systems Measures of Water Distribution System Resilience

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  20. Structural and Functional Connectivity from Unmanned-Aerial System Data

    Science.gov (United States)

    Masselink, Rens; Heckmann, Tobias; Casalí, Javier; Giménez, Rafael; Cerdá, Artemi; Keesstra, Saskia

    2017-04-01

    Over the past decade there has been an increase in both connectivity research and research involving Unmanned-Aerial systems (UASs). In some studies, UASs were successfully used for the assessment of connectivity, but not yet to their full potential. We present several ways to use data obtained from UASs to measure variables related to connectivity, and use these to assess both structural and functional connectivity. These assessments of connectivity can aid us in obtaining a better understanding of the dynamics of e.g. sediment and nutrient transport. We identify three sources of data obtained from a consumer camera mounted on a fixed-wing UAS, which can be used separately or combined: Visual and near-infrared imagery, point clouds, and digital elevation models (DEMs). Imagery (or: orthophotos) can be used for (automatic) mapping of connectivity features like rills, gullies and soil and water conservation measures using supervised or unsupervised classification methods with e.g. Object-Based Image Analysis. Furthermore, patterns of soil moisture in the top layers can be extracted from visual and near-infrared imagery. Point clouds can be analysed for vegetation height and density, and soil surface roughness. Lastly, DEMs can be used in combination with imagery for a number of tasks, including raster-based (e.g. DEM derivatives) and object-based (e.g., feature detection) analysis: Flow routing algorithms can be used to analyse potential pathways of surface runoff and sediment transport. This allows for the assessment of structural connectivity through indices that are based, for example, on morphometric and other properties of surfaces, contributing areas, and pathways. Third, erosion and deposition can be measured by calculating elevation changes from repeat surveys. From these "intermediate" variables like roughness, vegetation density and soil moisture, structural connectivity and functional connectivity can be assessed by combining them into a dynamic index of

  1. Grid Interaction of MV-connected CHP-plants during disturbances

    NARCIS (Netherlands)

    Coster, E.J.; Myrzik, J.M.A.; Kling, W.L.

    2009-01-01

    Nowadays the amount of distributed generation (DG) units is increasing rapidly. Most dominant are combined heat and power (CHP) plants and wind turbines. At this moment, in most systems, there are no requirements defined for short-circuit behavior of such generators connected to the medium voltage

  2. State Electricity Regulatory Policy and Distributed Resources: Distributed Resources and Electric System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Cowart, R.; Harrington, C.; Moskovitz, D.; Shirley, W.; Weston, F.; Sedano, R.

    2002-10-01

    Designing and implementing credit-based pilot programs for distributed resources distribution is a low-cost, low-risk opportunity to find out how these resources can help defer or avoid costly electric power system (utility grid) distribution upgrades. This report describes implementation options for deaveraged distribution credits and distributed resource development zones. Developing workable programs implementing these policies can dramatically increase the deployment of distributed resources in ways that benefit distributed resource vendors, users, and distribution utilities. This report is one in the State Electricity Regulatory Policy and Distributed Resources series developed under contract to NREL (see Annual Technical Status Report of the Regulatory Assistance Project: September 2000-September 2001, NREL/SR-560-32733). Other titles in this series are: (1) Accommodating Distributed Resources in Wholesale Markets, NREL/SR-560-32497; (2) Distributed Resources and Electric System Re liability, NREL/SR-560-32498; (3) Distribution System Cost Methodologies for Distributed Generation, NREL/SR-560-32500; (4) Distribution System Cost Methodologies for Distributed Generation Appendices, NREL/SR-560-32501.

  3. A Sensorless Power Reserve Control Strategy for Two-Stage Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    Due to the still increasing penetration of grid-connected Photovoltaic (PV) systems, advanced active power control functionalities have been introduced in grid regulations. A power reserve control, where namely the active power from the PV panels is reserved during operation, is required for grid...... support. In this paper, a cost-effective solution to realize the power reserve for two-stage grid-connected PV systems is proposed. The proposed solution routinely employs a Maximum Power Point Tracking (MPPT) control to estimate the available PV power and a Constant Power Generation (CPG) control...... performed on a 3-kW two-stage single-phase grid-connected PV system, where the power reserve control is achieved upon demands....

  4. Suggested Grid Code Modifications to Ensure Wide-Scale Adoption of Photovoltaic Energy in Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Enjeti, Prasad; Blaabjerg, Frede

    2013-01-01

    Current grid standards seem to largely require low power (e.g. several kilowatts) single-phase photovoltaic (PV) systems to operate at unity power factor with maximum power point tracking, and disconnect from the grid under grid faults. However, in case of a wide-scale penetration of single......-phase PV systems in the distributed grid, the disconnection under grid faults can contribute to: a) voltage flickers, b) power outages, and c) system instability. In this paper, grid code modifications are explored for wide-scale adoption of PV systems in the distribution grid. More recently, Italy...... and Japan, have undertaken a major review of standards for PV power conversion systems connected to low voltage networks. In view of this, the importance of low voltage ride-through for single-phase PV power systems under grid faults along with reactive power injection is studied in this paper. Three...

  5. Reliability Evaluation of Distribution System Considering Sequential Characteristics of Distributed Generation

    Directory of Open Access Journals (Sweden)

    Sheng Wanxing

    2016-01-01

    Full Text Available In allusion to the randomness of output power of distributed generation (DG, a reliability evaluation model based on sequential Monte Carlo simulation (SMCS for distribution system with DG is proposed. Operating states of the distribution system can be sampled by SMCS in chronological order thus the corresponding output power of DG can be generated. The proposed method has been tested on feeder F4 of IEEE-RBTS Bus 6. The results show that reliability evaluation of distribution system considering the uncertainty of output power of DG can be effectively implemented by SMCS.

  6. Linear Approach for Synchronous State Stability in Fully Connected PLL Networks

    Directory of Open Access Journals (Sweden)

    José R. C. Piqueira

    2008-01-01

    Full Text Available Synchronization is an essential feature for the use of digital systems in telecommunication networks, integrated circuits, and manufacturing automation. Formerly, master-slave (MS architectures, with precise master clock generators sending signals to phase-locked loops (PLLs working as slave oscillators, were considered the best solution. Nowadays, the development of wireless networks with dynamical connectivity and the increase of the size and the operation frequency of integrated circuits suggest that the distribution of clock signals could be more efficient if distributed solutions with fully connected oscillators are used. Here, fully connected networks with second-order PLLs as nodes are considered. In previous work, how the synchronous state frequency for this type of network depends on the node parameters and delays was studied and an expression for the long-term frequency was derived (Piqueira, 2006. Here, by taking the first term of the Taylor series expansion for the dynamical system description, it is shown that for a generic network with N nodes, the synchronous state is locally asymptotically stable.

  7. Height system connection between island and mainland using a hydrodynamic model: a case study connecting the Dutch Wadden islands to the Amsterdam ordnance datum (NAP)

    Science.gov (United States)

    Slobbe, D. C.; Klees, R.; Verlaan, M.; Zijl, F.; Alberts, B.; Farahani, H. H.

    2018-03-01

    We present an efficient and flexible alternative method to connect islands and offshore tide gauges with the height system on land. The method uses a regional, high-resolution hydrodynamic model that provides total water levels. From the model, we obtain the differences in mean water level (MWL) between tide gauges at the mainland and at the islands or offshore platforms. Adding them to the MWL relative to the national height system at the mainland's tide gauges realizes a connection of the island and offshore platforms with the height system on the mainland. Numerical results are presented for the connection of the Dutch Wadden islands with the national height system (Normaal Amsterdams Peil, NAP). Several choices of the period over which the MWLs are computed are tested and validated. The best results were obtained when we computed the MWL only over the summer months of our 19-year simulation period. Based on this strategy, the percentage of connections for which the absolute differences between the observation- and model-derived MWL differences are ≤ 1 cm is about 34% (46 out of 135 possible leveling connections). In this case, for each Wadden island we can find several connections that allow the transfer of NAP with (sub-)centimeter accuracy.

  8. Management tools for distributed control system in KSTAR

    International Nuclear Information System (INIS)

    Sangil Lee; Jinseop Park; Jaesic Hong; Mikyung Park; Sangwon Yun

    2012-01-01

    The integrated control system of the Korea Superconducting Tokamak Advanced Research (KSTAR) has been developed with distributed control systems based on Experimental Physics and Industrial Control System (EPICS) middle-ware. It has the essential role of remote operation, supervising of tokamak device and conducting of plasma experiments without any interruption. Therefore, the availability of the control system directly impacts on the entire device performance. For the non-interrupted operation of the KSTAR control system, we have developed a tool named as Control System Monitoring (CSM) to monitor the resources of EPICS Input/Output Controller (IOC) servers (utilization of memory, cpu, disk, network, user-defined process and system-defined process), the soundness of storage systems (storage utilization, storage status), the status of network switches using Simple Network Management Protocol (SNMP), the network connection status of every local control sever using Internet Control Message Protocol (ICMP), and the operation environment of the main control room and the computer room (temperature, humidity, electricity) in real time. When abnormal conditions or faults are detected by the CSM, it alerts abnormal or fault alarms to operators. Especially, if critical fault related to the data storage occurs, the CSM sends the simple messages to operator's mobile phone. The operators then quickly restored the problems according to the emergency procedure. As a result of this process, KSTAR was able to perform continuous operation and experiment without interruption for 4 months

  9. Distributed processing in receivers based on tensor for cooperative communications systems

    OpenAIRE

    Igor FlÃvio SimÃes de Sousa

    2014-01-01

    In this dissertation, we present a distributed data estimation and detection approach for the uplink of a network that uses CDMA at transmitters (users). The analyzed network can be represented by an undirected and connected graph, where the nodes use a distributed estimation algorithm based on consensus averaging to perform joint channel and symbol estimation using a receiver based on tensor signal processing. The centralized receiver, developed for a central base station, and the distribute...

  10. Islanding Operation of Distribution System with Distributed Generations

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    The growing interest in distributed generations (DGs) due to environmental concern and various other reasons have resulted in significant penetration of DGs in many distribution system worldwide. DGs come with many benefits. One of the benefits is improved reliability by supplying load during power...

  11. Altered resting-state functional connectivity of the frontal-striatal reward system in social anxiety disorder.

    Science.gov (United States)

    Manning, Joshua; Reynolds, Gretchen; Saygin, Zeynep M; Hofmann, Stefan G; Pollack, Mark; Gabrieli, John D E; Whitfield-Gabrieli, Susan

    2015-01-01

    We investigated differences in the intrinsic functional brain organization (functional connectivity) of the human reward system between healthy control participants and patients with social anxiety disorder. Functional connectivity was measured in the resting-state via functional magnetic resonance imaging (fMRI). 53 patients with social anxiety disorder and 33 healthy control participants underwent a 6-minute resting-state fMRI scan. Functional connectivity of the reward system was analyzed by calculating whole-brain temporal correlations with a bilateral nucleus accumbens seed and a ventromedial prefrontal cortex seed. Patients with social anxiety disorder, relative to the control group, had (1) decreased functional connectivity between the nucleus accumbens seed and other regions associated with reward, including ventromedial prefrontal cortex; (2) decreased functional connectivity between the ventromedial prefrontal cortex seed and lateral prefrontal regions, including the anterior and dorsolateral prefrontal cortices; and (3) increased functional connectivity between both the nucleus accumbens seed and the ventromedial prefrontal cortex seed with more posterior brain regions, including anterior cingulate cortex. Social anxiety disorder appears to be associated with widespread differences in the functional connectivity of the reward system, including markedly decreased functional connectivity between reward regions and between reward regions and lateral prefrontal cortices, and markedly increased functional connectivity between reward regions and posterior brain regions.

  12. Research on Distributed PV Storage Virtual Synchronous Generator System and Its Static Frequency Characteristic Analysis

    Directory of Open Access Journals (Sweden)

    Xiangwu Yan

    2018-03-01

    Full Text Available The increasing penetration rate of grid connected renewable energy power generation reduces the primary frequency regulation capability of the system and poses a challenge to the security and stability of the power grid. In this paper, a distributed photovoltaic (PV storage virtual synchronous generator system is constructed, which realizes the external characteristics of synchronous generator/motor. For this kind of input/output bidirectional devices (e.g., renewable power generation/storage combined systems, pumped storage power stations, battery energy storage systems, and vehicle-to-grid electric vehicles, a synthesis analysis method for system power-frequency considering source-load static frequency characteristics (S-L analysis method is proposed in order to depict the system’s power balance dynamic adjustment process visually. Simultaneously, an inertia matching method is proposed to solve the problem of inertia matching in the power grid. Through the simulation experiment in MATLAB, the feasibility of the distributed PV storage synchronous virtual machine system is verified as well as the effectiveness of S-L analysis method and inertia matching method.

  13. System Efficiency of a Tap Transformer Based Grid Connection Topology Applied on a Direct Driven Generator for Wind Power

    Directory of Open Access Journals (Sweden)

    Senad Apelfröjd

    2014-01-01

    Full Text Available Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed.

  14. System efficiency of a tap transformer based grid connection topology applied on a direct driven generator for wind power.

    Science.gov (United States)

    Apelfröjd, Senad; Eriksson, Sandra

    2014-01-01

    Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed.

  15. System Efficiency of a Tap Transformer Based Grid Connection Topology Applied on a Direct Driven Generator for Wind Power

    Science.gov (United States)

    2014-01-01

    Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed. PMID:25258733

  16. Quantum-Classical Connection for Hydrogen Atom-Like Systems

    Science.gov (United States)

    Syam, Debapriyo; Roy, Arup

    2011-01-01

    The Bohr-Sommerfeld quantum theory specifies the rules of quantization for circular and elliptical orbits for a one-electron hydrogen atom-like system. This article illustrates how a formula connecting the principal quantum number "n" and the length of the major axis of an elliptical orbit may be arrived at starting from the quantum…

  17. Connecting two jumplike unravelings for non-Markovian open quantum systems

    Energy Technology Data Exchange (ETDEWEB)

    Luoma, Kimmo; Suominen, Kalle-Antti; Piilo, Jyrki [Turku Centre for Quantum Physics, Department of Physics and Astronomy, University of Turku, FI-20014 Turun Yliopisto (Finland)

    2011-09-15

    The development and use of Monte Carlo algorithms plays a visible role in the study of non-Markovian quantum dynamics due to the provided insight and powerful numerical methods for solving the system dynamics. In the Markovian case, the connections between the various types of methods are fairly well understood while, for the non-Markovian case, there has so far been only a few studies. We focus here on two jumplike unravelings of non-Markovian dynamics: the non-Markovian quantum jump (NMQJ) method and the property state method by Gambetta, Askerud, and Wiseman (GAW). The results for simple quantum optical systems illustrate the connections between the realizations of the two methods and also highlight how the probability currents between the system and environment, or between the property states of the total system, are associated with the decay rates of time-local master equations and, consequently, with the jump rates of the NMQJ method.

  18. Connecting two jumplike unravelings for non-Markovian open quantum systems

    International Nuclear Information System (INIS)

    Luoma, Kimmo; Suominen, Kalle-Antti; Piilo, Jyrki

    2011-01-01

    The development and use of Monte Carlo algorithms plays a visible role in the study of non-Markovian quantum dynamics due to the provided insight and powerful numerical methods for solving the system dynamics. In the Markovian case, the connections between the various types of methods are fairly well understood while, for the non-Markovian case, there has so far been only a few studies. We focus here on two jumplike unravelings of non-Markovian dynamics: the non-Markovian quantum jump (NMQJ) method and the property state method by Gambetta, Askerud, and Wiseman (GAW). The results for simple quantum optical systems illustrate the connections between the realizations of the two methods and also highlight how the probability currents between the system and environment, or between the property states of the total system, are associated with the decay rates of time-local master equations and, consequently, with the jump rates of the NMQJ method.

  19. The equipment access software for a distributed UNIX-based accelerator control system

    International Nuclear Information System (INIS)

    Trofimov, Nikolai; Zelepoukine, Serguei; Zharkov, Eugeny; Charrue, Pierre; Gareyte, Claire; Poirier, Herve

    1994-01-01

    This paper presents a generic equipment access software package for a distributed control system using computers with UNIX or UNIX-like operating systems. The package consists of three main components, an application Equipment Access Library, Message Handler and Equipment Data Base. An application task, which may run in any computer in the network, sends requests to access equipment through Equipment Library calls. The basic request is in the form Equipment-Action-Data and is routed via a remote procedure call to the computer to which the given equipment is connected. In this computer the request is received by the Message Handler. According to the type of the equipment connection, the Message Handler either passes the request to the specific process software in the same computer or forwards it to a lower level network of equipment controllers using MIL1553B, GPIB, RS232 or BITBUS communication. The answer is then returned to the calling application. Descriptive information required for request routing and processing is stored in the real-time Equipment Data Base. The package has been written to be portable and is currently available on DEC Ultrix, LynxOS, HPUX, XENIX, OS-9 and Apollo domain. ((orig.))

  20. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.

    Science.gov (United States)

    Carvalho, Marco Aurélio; Sotto-Maior, Bruno Salles; Del Bel Cury, Altair Antoninha; Pessanha Henriques, Guilherme Elias

    2014-11-01

    Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections

  1. Flexible Mode Control of Grid Connected Wind Energy Conversion System Using Wavelet

    Directory of Open Access Journals (Sweden)

    Bhavna Jain

    2015-01-01

    Full Text Available Small wind turbine systems offer services to critical loads during grid faults and also connected back to grid in normal condition. The connection of a wind energy conversion system to the grid requires a robust phase locked loop (PLL and continuous monitoring of the grid conditions such as overvoltage, undervoltage, overfrequency, underfrequency, and grid outages. This paper describes a flexible control operation to operate a small wind turbine in both stand-alone mode via planned islanding and grid connected mode as well. In particular, a proper monitoring and control algorithm is required for transition between the modes. A wavelet based energy function is used for detection of grid disturbances as well as recovery of grid so that transition between the modes is made. To obtain good power quality LCL filter is used to reduce ripples. PLL is used for synchronization whenever mode changes from stand-alone to grid connected. Simulation results from a 10 kW wind energy conversion system are included to show the usefulness of the proposed methods. The control method is tested by generated gate pulses for single phase bridge inverter using field programmable gate array (FPGA.

  2. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, F.; Sørensen, Poul Ejnar; Hansen, A.D.

    2005-01-01

    Currently, there is an increasing trend to connect large MW wind farms to the transmission system. Requirements that focus on the influence of the farms on the grid stability and power quality, and on the control capabilities of wind farms have already been established. The main trends of modern...... wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly fed induction generators. Using power electronics the control capabilities of these wind turbines/farms are extended and thus the grid requirements...... are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...

  3. Distributed photovoltaic generation in Brazil: An economic viability analysis of small-scale photovoltaic systems in the residential and commercial sectors

    International Nuclear Information System (INIS)

    Holdermann, Claudius; Kissel, Johannes; Beigel, Jürgen

    2014-01-01

    This paper examines the economic viability of small-scale, grid-connected photovoltaics in the Brazilian residential and commercial sectors after the introduction of the net metering regulation in April 2012. This study uses the discounted cash flow method to calculate the specific investment costs that are necessary for photovoltaic systems to be economically viable for each of the 63 distribution networks in Brazil. We compare these values to the system costs that are estimated in the comprehensive study on photovoltaics that was developed by the Brazilian Association of Electric and Electronic Industries (ABINEE). In our calculation, we utilize the current electricity tariffs, including fees and taxes, which we obtained through telephone interviews and publicly available information. We obtained a second important parameter by simulating PV-systems with the program PV ⁎ Sol at the distribution company headquarters' locations. In our base case scenario that reflects the current situation, in none of the distribution networks photovoltaics is economically viable in either the commercial or residential sectors. We improved the environment for grid-connected photovoltaics in our scenarios by assuming both lower PV-system costs and a lower discount rate to determine the effect on photovoltaics viability. - Highlights: • We calculate the economic viability of photovoltaics in the residential and commercial sectors in Brazil. • The PV ⁎ Sol simulations are carried out at the headquarter locations for the 63 distribution companies. • Currently in none of the distribution networks, photovoltaics is economically viable in either the commercial or residential sectors. • We analyze how the variation of the specific investment costs and of the discount rate affects the economic viability

  4. Adaptive Curtailment Plan with Energy Storage for AC/DC Combined Distribution Systems

    Directory of Open Access Journals (Sweden)

    Seungmin Jung

    2016-08-01

    Full Text Available For developing a large-scale combined system with a number of distributed resources, an appropriate compensation strategy based on the system components and changeable condition must be configured to handle the characteristics of the internal systems. Since renewable sources generate various fluctuations, the compensation plans for the storage device connected along with the sources should be supported by a precise expectation method. A cooperative strategy involving the sharing of the DC section with environmentally sensitive generators, like photovoltaic system (PVs or waves, demands appropriate ESS compensation solutions, owing to its complexity. An active power-control algorithm with voltage-expectation based on the DC power flow is introduced in this paper and is applied in the designed case studies performed on the electromagnetic transient simulation. DC based multi-generation system is composed by applying tidal generator and super capacitor. To utilize wind energy, an offshore wind–wave generation system was utilized in the verification process.

  5. Advanced Distribution Management System

    OpenAIRE

    Avazov, Artur; Sobinova, Lubov Anatolievna

    2016-01-01

    This article describes the advisability of using advanced distribution management systems in the electricity distribution networks area and considers premises of implementing ADMS within the Smart Grid era. Also, it gives the big picture of ADMS and discusses the ADMS advantages and functionalities.

  6. Advanced Distribution Management System

    Science.gov (United States)

    Avazov, Artur R.; Sobinova, Liubov A.

    2016-02-01

    This article describes the advisability of using advanced distribution management systems in the electricity distribution networks area and considers premises of implementing ADMS within the Smart Grid era. Also, it gives the big picture of ADMS and discusses the ADMS advantages and functionalities.

  7. System modelling and energy management for grid connected PV systems associated with storage

    OpenAIRE

    Riffonneau , Yann; DELAILLE , Arnaud; Barruel , Franck; Bacha , Seddik

    2008-01-01

    International audience; This paper presents the modelling and energy management of a grid connected PV system associatedwith storage. Within the economic, energetic and environmental context, objective of the system is to ensure loadssupply at the least cost by optimising the use of solar power. Therefore, due to the complicated operating patterns, anenergy management system which decides on energy flow for any moment is necessary. First, we present the systemstudied. Based on an AC bus typol...

  8. Flexible Mode Control of Grid Connected Wind Energy Conversion System Using Wavelet

    OpenAIRE

    Jain, Bhavna; Singh, Sameer; Jain, Shailendra; Nema, R. K.

    2015-01-01

    Small wind turbine systems offer services to critical loads during grid faults and also connected back to grid in normal condition. The connection of a wind energy conversion system to the grid requires a robust phase locked loop (PLL) and continuous monitoring of the grid conditions such as overvoltage, undervoltage, overfrequency, underfrequency, and grid outages. This paper describes a flexible control operation to operate a small wind turbine in both stand-alone mode via planned islanding...

  9. Nevos de tejido conectivo Connective tissue nevi

    Directory of Open Access Journals (Sweden)

    RE Achenbach

    Full Text Available Comunicamos dos casos de nevo del tejido conectivo, el primero con patrón histológico mixto y el segundo con predominio de alteraciones en las fibras elásticas. No se constataron síndromes ni patología sistémica asociada. Un caso presentó disposición linear y un nevo acrómico asociado.Two cases of connective tissue nevi are reported, one of them with a mixed histopatologic pattern and one with elastin fibers diminished. None of the patients had systemic involvement or associated syndromes. The mixed connective tissue nevi type showed a linear distribution and has associated an acromic nevi.

  10. Control and Operation of Islanded Distribution System

    DEFF Research Database (Denmark)

    Mahat, Pukar

    deviation and real power shift. When a distribution system, with all its generators operating at maximum power, is islanded, the frequency will go down if the total load is more than the total generation. An under-frequency load shedding procedure for islanded distribution systems with DG unit(s) based...... states. Short circuit power also changes when some of the generators in the distribution system are disconnected. This may result in elongation of fault clearing time and hence disconnection of equipments (including generators) in the distribution system or unnecessary operation of protective devices...... operational challenges. But, on the other hand, it has also opened up some opportunities. One opportunity/challenge is an islanded operation of a distribution system with DG unit(s). Islanding is a situation in which a distribution system becomes electrically isolated from the remainder of the power system...

  11. Water Treatment Technology - Distribution Systems.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on distribution systems provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pipe for distribution systems, types…

  12. Integrating photovoltaics into utility distribution systems

    International Nuclear Information System (INIS)

    Zaininger, H.W.; Barnes, P.R.

    1995-01-01

    Electric utility distribution system impacts associated with the integration of distributed photovoltaic (PV) energy sources vary from site to site and utility to utility. The objective of this paper is to examine several utility- and site-specific conditions which may affect economic viability of distributed PV applications to utility systems. Assessment methodology compatible with technical and economic assessment techniques employed by utility engineers and planners is employed to determine PV benefits for seven different utility systems. The seven case studies are performed using utility system characteristics and assumptions obtained from appropriate utility personnel. The resulting site-specific distributed PV benefits increase nonsite-specific generation system benefits available to central station PV plants as much as 46%, for one utility located in the Southwest

  13. Bolted Flanged Connection for Critical Plant/Piping Systems

    International Nuclear Information System (INIS)

    Efremov, Anatoly

    2006-01-01

    A novel type of Bolted Flanged Connection with bolts and gasket manufactured on a basis of advanced Shape Memory Alloys is examined. Presented approach combined with inverse flexion flange design of plant/piping joint reveals a significant increase of internal pressure under conditions of a variety of operating temperatures relating to critical plant/piping systems. (author)

  14. Planning and Optimization Methods for Active Distribution Systems

    DEFF Research Database (Denmark)

    Abbey, Chad; Baitch, Alex; Bak-Jensen, Birgitte

    distribution planning. Active distribution networks (ADNs) have systems in place to control a combination of distributed energy resources (DERs), defined as generators, loads and storage. With these systems in place, the AND becomes an Active Distribution System (ADS). Distribution system operators (DSOs) have...

  15. Electric power distribution handbook

    CERN Document Server

    Short, Thomas Allen

    2014-01-01

    Of the ""big three"" components of electrical infrastructure, distribution typically gets the least attention. In fact, a thorough, up-to-date treatment of the subject hasn't been published in years, yet deregulation and technical changes have increased the need for better information. Filling this void, the Electric Power Distribution Handbook delivers comprehensive, cutting-edge coverage of the electrical aspects of power distribution systems. The first few chapters of this pragmatic guidebook focus on equipment-oriented information and applications such as choosing transformer connections,

  16. Distributed Power-Generation Systems and Protection

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng; Yang, Dongsheng

    2017-01-01

    the challenging issues and, more importantly, to leverage the energy generation, stringent demands from both utility operators and consumers have been imposed on the DPGS. Furthermore, as the core of energy conversion, numerous power electronic converters employing advanced control techniques have been developed...... for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS...

  17. Coordination control of distributed systems

    CERN Document Server

    Villa, Tiziano

    2015-01-01

    This book describes how control of distributed systems can be advanced by an integration of control, communication, and computation. The global control objectives are met by judicious combinations of local and nonlocal observations taking advantage of various forms of communication exchanges between distributed controllers. Control architectures are considered according to  increasing degrees of cooperation of local controllers:  fully distributed or decentralized control,  control with communication between controllers,  coordination control, and multilevel control.  The book covers also topics bridging computer science, communication, and control, like communication for control of networks, average consensus for distributed systems, and modeling and verification of discrete and of hybrid systems. Examples and case studies are introduced in the first part of the text and developed throughout the book. They include: control of underwater vehicles, automated-guided vehicles on a container terminal, contro...

  18. Study on optimal configuration of the grid-connected wind-solar-battery hybrid power system

    Science.gov (United States)

    Ma, Gang; Xu, Guchao; Ju, Rong; Wu, Tiantian

    2017-08-01

    The capacity allocation of each energy unit in the grid-connected wind-solar-battery hybrid power system is a significant segment in system design. In this paper, taking power grid dispatching into account, the research priorities are as follows: (1) We establish the mathematic models of each energy unit in the hybrid power system. (2) Based on dispatching of the power grid, energy surplus rate, system energy volatility and total cost, we establish the evaluation system for the wind-solar-battery power system and use a number of different devices as the constraint condition. (3) Based on an improved Genetic algorithm, we put forward a multi-objective optimisation algorithm to solve the optimal configuration problem in the hybrid power system, so we can achieve the high efficiency and economy of the grid-connected hybrid power system. The simulation result shows that the grid-connected wind-solar-battery hybrid power system has a higher comprehensive performance; the method of optimal configuration in this paper is useful and reasonable.

  19. Representing connectivity: quantifying effective habitat availability based on area and connectivity for conservation status assessment and recovery.

    Science.gov (United States)

    Neel, Maile; Tumas, Hayley R; Marsden, Brittany W

    2014-01-01

    We apply a comprehensive suite of graph theoretic metrics to illustrate how landscape connectivity can be effectively incorporated into conservation status assessments and in setting conservation objectives. These metrics allow conservation practitioners to evaluate and quantify connectivity in terms of representation, resiliency, and redundancy and the approach can be applied in spite of incomplete knowledge of species-specific biology and dispersal processes. We demonstrate utility of the graph metrics by evaluating changes in distribution and connectivity that would result from implementing two conservation plans for three endangered plant species (Erigeron parishii, Acanthoscyphus parishii var. goodmaniana, and Eriogonum ovalifolium var. vineum) relative to connectivity under current conditions. Although distributions of the species differ from one another in terms of extent and specific location of occupied patches within the study landscape, the spatial scale of potential connectivity in existing networks were strikingly similar for Erigeron and Eriogonum, but differed for Acanthoscyphus. Specifically, patches of the first two species were more regularly distributed whereas subsets of patches of Acanthoscyphus were clustered into more isolated components. Reserves based on US Fish and Wildlife Service critical habitat designation would not greatly contribute to maintain connectivity; they include 83-91% of the extant occurrences and >92% of the aerial extent of each species. Effective connectivity remains within 10% of that in the whole network for all species. A Forest Service habitat management strategy excluded up to 40% of the occupied habitat of each species resulting in both range reductions and loss of occurrences from the central portions of each species' distribution. Overall effective network connectivity was reduced to 62-74% of the full networks. The distance at which each CHMS network first became fully connected was reduced relative to the full

  20. Modal analysis of a grid-connected direct-drive permanent magnet synchronous generator wind turbine system

    DEFF Research Database (Denmark)

    Tan, Jin; Wang, Xiao Ru; Chen, Zhe

    2013-01-01

    In order to study the stability of a grid-connected direct-drive permanent magnet synchronous generator (PMSG) wind turbine systems, this paper presents the modal analysis of a PMSG wind turbine system. A PMSG model suitable for small signal stability analysis is presented. The modal properties...... of a grid-connected PMSG wind turbine system are studied. Then the comprehensive impacts of the shaft model, shaft parameters, operation points and lengths of the transmission line on the modal characteristic of the system are investigated by the eigenvalue analysis method. Meanwhile, the corresponding...... analysis. It offers a better understanding about the essence of the stability of grid-connected PMSG wind turbine system....

  1. Estimating time-dependent connectivity in marine systems

    Science.gov (United States)

    Defne, Zafer; Ganju, Neil K.; Aretxabaleta, Alfredo

    2016-01-01

    Hydrodynamic connectivity describes the sources and destinations of water parcels within a domain over a given time. When combined with biological models, it can be a powerful concept to explain the patterns of constituent dispersal within marine ecosystems. However, providing connectivity metrics for a given domain is a three-dimensional problem: two dimensions in space to define the sources and destinations and a time dimension to evaluate connectivity at varying temporal scales. If the time scale of interest is not predefined, then a general approach is required to describe connectivity over different time scales. For this purpose, we have introduced the concept of a “retention clock” that highlights the change in connectivity through time. Using the example of connectivity between protected areas within Barnegat Bay, New Jersey, we show that a retention clock matrix is an informative tool for multitemporal analysis of connectivity.

  2. On the Distribution of Lightning Current among Interconnected Grounding Systems in Medium Voltage Grids

    Directory of Open Access Journals (Sweden)

    Guido Ala

    2018-03-01

    Full Text Available This paper presents the results of a first investigation on the effects of lightning stroke on medium voltage installations’ grounding systems, interconnected with the metal shields of the Medium Voltage (MV distribution grid cables or with bare buried copper ropes. The study enables us to evaluate the distribution of the lightning current among interconnected ground electrodes in order to estimate if the interconnection, usually created to reduce ground potential rise during a single-line-to-ground fault, can give place to dangerous situations far from the installation hit by the lightning stroke. Four different case studies of direct lightning stroke are presented and discussed: (1 two secondary substations interconnected by the cables’ shields; (2 two secondary substations interconnected by a bare buried conductor; (3 a high voltage/medium voltage station connected with a secondary substation by the medium voltage cables’ shields; (4 a high voltage/medium voltage station connected with a secondary substation by a bare buried conductor. The results of the simulations show that a higher peak-lowering action on the lighting-stroke current occurs due to the use of bare conductors as interconnection elements in comparison to the cables’ shields.

  3. Advanced Distribution Management System

    Directory of Open Access Journals (Sweden)

    Avazov Artur R.

    2016-01-01

    Full Text Available This article describes the advisability of using advanced distribution management systems in the electricity distribution networks area and considers premises of implementing ADMS within the Smart Grid era. Also, it gives the big picture of ADMS and discusses the ADMS advantages and functionalities.

  4. Devaney chaos plus shadowing implies distributional chaos.

    Science.gov (United States)

    Li, Jian; Li, Jie; Tu, Siming

    2016-09-01

    We explore connections among the regional proximal relation, the asymptotic relation, and the distal relation for a topological dynamical system with the shadowing property and show that if a Devaney chaotic system has the shadowing property then it is distributionally chaotic.

  5. Agent-Based Modelling of the Evolution of the Russian Party System Based on Pareto and Hotelling Distributions. Part II

    Directory of Open Access Journals (Sweden)

    Владимир Геннадьевич Иванов

    2015-12-01

    Full Text Available The given article presents research of the evolution of the Russian party system. The chosen methodology is based on the heuristic potential of agent-based modelling. The author analyzes various scenarios of parties’ competition (applying Pareto distribution in connection with recent increase of the number of political parties. In addition, the author predicts the level of ideological diversity of the parties’ platforms (applying the principles of Hotelling distribution in order to evaluate their potential competitiveness in the struggle for voters.

  6. Optimizing electrical distribution systems

    International Nuclear Information System (INIS)

    Scott, W.G.

    1990-01-01

    Electrical utility distribution systems are in the middle of an unprecedented technological revolution in planning, design, maintenance and operation. The prime movers of the revolution are the major economic shifts that affect decision making. The major economic influence on the revolution is the cost of losses (technical and nontechnical). The vehicle of the revolution is the computer, which enables decision makers to examine alternatives in greater depth and detail than their predecessors could. The more important elements of the technological revolution are: system planning, computers, load forecasting, analytical systems (primary systems, transformers and secondary systems), system losses and coming technology. The paper is directed towards the rather unique problems encountered by engineers of utilities in developing countries - problems that are being solved through high technology, such as the recent World Bank-financed engineering computer system for Sri Lanka. This system includes a DEC computer, digitizer, plotter and engineering software to model the distribution system via a digitizer, analyse the system and plot single-line diagrams. (author). 1 ref., 4 tabs., 6 figs

  7. Trend chart: bio-methane injected in gas distribution systems. Third quarter 2017

    International Nuclear Information System (INIS)

    Moreau, Sylvain

    2017-11-01

    This publication presents the bio-methane industry situation of continental France and overseas territories during the third quarter 2017: bio-methane production facilities, new connected facilities, regional distribution of facilities, evolution of quarterly production, distribution of facilities versus capacity and type, evolution forecasts of bio-methane production, detailed regional results

  8. Trend chart: bio-methane injected in gas distribution systems. Second quarter 2017

    International Nuclear Information System (INIS)

    2017-08-01

    This publication presents the bio-methane industry situation of continental France and overseas territories during the first quarter 2017: bio-methane production facilities, new connected facilities, regional distribution of facilities, evolution of quarterly production, distribution of facilities versus capacity and type, evolution forecasts of bio-methane production, detailed regional results

  9. Trend chart: bio-methane injected in gas distribution systems. Fourth quarter 2017

    International Nuclear Information System (INIS)

    Moreau, Sylvain

    2018-02-01

    This publication presents the bio-methane industry situation of continental France and overseas territories during the fourth quarter 2017: bio-methane production facilities, new connected facilities, regional distribution of facilities, evolution of quarterly production, distribution of facilities versus capacity and type, evolution forecasts of bio-methane production, detailed regional results

  10. The German experience with grid-connected PV-systems

    International Nuclear Information System (INIS)

    Erge, T.; Hoffmann, V.U.; Kiefer, K.

    2001-01-01

    Grid-connected photovoltaics experienced increasing attention in Germany in recent years and are expected to face a major boost at the beginning of the new millennium. Highlights like the German 100,000-Roofs-Solar-Programme, PV programmes at schools financed by utilities and governments (e.g. 'SONNEonline' by PreussenElektra, 'Sonne in der Schule' by BMWi and 'Sonne in der Schule' by Bayernwerk) and large centralised installations of MW size ('Neue Messe Munchen' by Bayernwerk and 'Energiepark Mont-Cenis' by state Nordrhein-Westfalen, Stadtwerke Herne and European Union) count for the potential of grid-connected PV. Today in Germany a typical grid-connected PV installation of 1 kW nominal power produces average annual energy yields of 700 kWh (dependent on location and system components) and shows a high operating availability. The price per kWh from PV installations is still significantly higher than the price for conventional energy, but new funding schemes and cost models (like the large increase of feed-in tariff in Germany due to the Act on Granting Priority to Renewable Energy Sources in 2000) give optimism about the future. (Author)

  11. A New Power Calculation Method for Single-Phase Grid-Connected Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    A new method to calculate average active power and reactive power for single-phase systems is proposed in this paper. It can be used in different applications where the output active power and reactive power need to be calculated accurately and fast. For example, a grid-connected photovoltaic...... system in low voltage ride through operation mode requires a power feedback for the power control loop. Commonly, a Discrete Fourier Transform (DFT) based power calculation method can be adopted in such systems. However, the DFT method introduces at least a one-cycle time delay. The new power calculation...... method, which is based on the adaptive filtering technique, can achieve a faster response. The performance of the proposed method is verified by experiments and demonstrated in a 1 kW single-phase grid-connected system operating under different conditions.Experimental results show the effectiveness...

  12. Hydrodynamic modeling of hydrologic surface connectivity within a coastal river-floodplain system

    Science.gov (United States)

    Castillo, C. R.; Guneralp, I.

    2017-12-01

    Hydrologic surface connectivity (HSC) within river-floodplain environments is a useful indicator of the overall health of riparian habitats because it allows connections amongst components/landforms of the riverine landscape system to be quantified. Overbank flows have traditionally been the focus for analyses concerned with river-floodplain connectivity, but recent works have identified the large significance from sub-bankfull streamflows. Through the use of morphometric analysis and a digital elevation model that is relative to the river water surface, we previously determined that >50% of the floodplain for Mission River on the Coastal Bend of Texas becomes connected to the river at streamflows well-below bankfull conditions. Guided by streamflow records, field-based inundation data, and morphometric analysis; we develop a two-dimensional hydrodynamic model for lower portions of Mission River Floodplain system. This model not only allows us to analyze connections induced by surface water inundation, but also other aspects of the hydrologic connectivity concept such as exchanges of sediment and energy between the river and its floodplain. We also aggregate hydrodynamic model outputs to an object/landform level in order to analyze HSC and associated attributes using measures from graph/network theory. Combining physically-based hydrodynamic models with object-based and graph theoretical analyses allow river-floodplain connectivity to be quantified in a consistent manner with measures/indicators commonly used in landscape analysis. Analyzes similar to ours build towards the establishment of a formal framework for analyzing river-floodplain interaction that will ultimately serve to inform the management of riverine/floodplain environments.

  13. Harmonic Interaction Analysis in Grid Connected Converter using Harmonic State Space (HSS) Modeling

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    -model, are introduced to analyze these problems. However, it is found that Linear Time Invariant (LTI) base model analysis makes it difficult to analyze these phenomenon because of time varying system operation trajectories, varying output impedance seen by grid connected systems and neglected switching component......An increasing number of power electronics based Distributed Generation (DG) systems and loads generate coupled harmonic as well as non-characteristic harmonic with each other. Several methods like impedance based analysis, which is derived from conventional small signal- and average...... during the modeling process. This paper investigates grid connected converter by means of Harmonic State Space (HSS) small signal model, which is modeled from Linear Time varying Periodically (LTP) system. Further, a grid connected converter harmonic matrix is investigated to analyze the harmonic...

  14. Energy efficient distributed computing systems

    CERN Document Server

    Lee, Young-Choon

    2012-01-01

    The energy consumption issue in distributed computing systems raises various monetary, environmental and system performance concerns. Electricity consumption in the US doubled from 2000 to 2005.  From a financial and environmental standpoint, reducing the consumption of electricity is important, yet these reforms must not lead to performance degradation of the computing systems.  These contradicting constraints create a suite of complex problems that need to be resolved in order to lead to 'greener' distributed computing systems.  This book brings together a group of outsta

  15. Bluetooth-based distributed measurement system

    International Nuclear Information System (INIS)

    Tang Baoping; Chen Zhuo; Wei Yuguo; Qin Xiaofeng

    2007-01-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit

  16. Bluetooth-based distributed measurement system

    Science.gov (United States)

    Tang, Baoping; Chen, Zhuo; Wei, Yuguo; Qin, Xiaofeng

    2007-07-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  17. Bluetooth-based distributed measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Tang Baoping; Chen Zhuo; Wei Yuguo; Qin Xiaofeng [Department of Mechatronics, College of Mechanical Engineering, Chongqing University, Chongqing, 400030 (China)

    2007-07-15

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  18. Allocation of losses in distribution system with dispersed generation of electricity

    International Nuclear Information System (INIS)

    Atanasovski, Metodija B.

    2005-01-01

    The problem of allocation of losses in distribution systems with dispersed generation (DG) of electricity is considered in this work. Definition of category DG, overview of technologies which belongs to this category and main features of each technology are given. Modeling of DG in steady state analysis of distribution networks is completely elaborated. Requirements for ideal allocation of losses are summarized. Methods from the literature, for allocation of losses in distribution systems with DG, are elaborated, as: classical distribution pricing method, substitution method, marginal loss coefficients method and nodal factors pricing method. In this work a new method for allocation of losses in distribution systems with DG is also presented. The new method is based on branches and resolves the problems of implementation of branch based methods for transmission networks to distribution networks. The method establishes direct relationship between losses in each branch of the network and injected active and reactive power in the nodes on which path to the root node the branch is placed. Reactive power is considered in the loss allocation process in this method and allocation of crossed terms of active and reactive power is performed using quadratic allocation of crossed terms. DG in this method is treated as negative power injection. It is assumed that the network is radial and the power flow in each branch of the, distribution network is constant and equal to the sum of injected active and reactive power in each node on which path to the root node, the branch is placed. The network is considered loss less. The new proposed method is applied and tested on real distribution network which is a part of Distribution company-Bitola. One distribution feeder of power station 110/10 kV/kV Bitola 4 is considered. Different types of consumers and two small hydro power plants in property of JP Strezevo as typical representatives of DG are connected to the feeder. Results

  19. Evaluating online data of water quality changes in a pilot drinking water distribution system with multivariate data exploration methods.

    Science.gov (United States)

    Mustonen, Satu M; Tissari, Soile; Huikko, Laura; Kolehmainen, Mikko; Lehtola, Markku J; Hirvonen, Arja

    2008-05-01

    The distribution of drinking water generates soft deposits and biofilms in the pipelines of distribution systems. Disturbances in water distribution can detach these deposits and biofilms and thus deteriorate the water quality. We studied the effects of simulated pressure shocks on the water quality with online analysers. The study was conducted with copper and composite plastic pipelines in a pilot distribution system. The online data gathered during the study was evaluated with Self-Organising Map (SOM) and Sammon's mapping, which are useful methods in exploring large amounts of multivariate data. The objective was to test the usefulness of these methods in pinpointing the abnormal water quality changes in the online data. The pressure shocks increased temporarily the number of particles, turbidity and electrical conductivity. SOM and Sammon's mapping were able to separate these situations from the normal data and thus make those visible. Therefore these methods make it possible to detect abrupt changes in water quality and thus to react rapidly to any disturbances in the system. These methods are useful in developing alert systems and predictive applications connected to online monitoring.

  20. Large scale network-centric distributed systems

    CERN Document Server

    Sarbazi-Azad, Hamid

    2014-01-01

    A highly accessible reference offering a broad range of topics and insights on large scale network-centric distributed systems Evolving from the fields of high-performance computing and networking, large scale network-centric distributed systems continues to grow as one of the most important topics in computing and communication and many interdisciplinary areas. Dealing with both wired and wireless networks, this book focuses on the design and performance issues of such systems. Large Scale Network-Centric Distributed Systems provides in-depth coverage ranging from ground-level hardware issu

  1. Distribution network strengthens sales systems

    International Nuclear Information System (INIS)

    Janoska, J.

    2003-01-01

    Liberalisation of the electricity market pushes Slovak distribution companies to upgrade their sale technologies. The first one to invest into a complex electronic sales system will be Stredoslovenska energetika, a.s., Zilina. The system worth 200 million Sk (4,83 million Euro) will be supplied by Polish software company Winuel. The company should also supply a software that would allow forecasting and planning of sales. The system should be fully operational by 2006. TREND has not managed to obtain information regarding plans Zapadoslovenska energetika - the largest and most active distribution company - might have in this area. In eastern Slovakia distribution company Vychodoslovenska energetika, a.s., Kosice has also started addressing this issue. (Author)

  2. THE RATIONALE FOR THE USE OF TWO-PHASE SWITCHES FOR THREE-PHASE CONNECTIONS OF DISTRIBUTIVE DEVICE 27.5 KV

    Directory of Open Access Journals (Sweden)

    Yu. Ya. Sheika

    2008-12-01

    Full Text Available On the basis of materials of scientists of Moscow and Petersburg State Universities of C Ways and NIIEFAENERGO Ltd.» the author of this article with additions has considered a practical possibility of us bipolar switches on three-phase connections of distributive device 27,5 кV.

  3. Trend chart: bio-methane injected in gas distribution systems. First quarter 2017

    International Nuclear Information System (INIS)

    2017-05-01

    This publication presents the bio-methane industry situation of continental France and overseas territories during the first quarter 2017: bio-methane production facilities, new connected facilities, regional distribution of facilities, evolution of quarterly production, distribution of facilities versus capacity and type, evolution forecasts of bio-methane production, detailed regional results, methodology used

  4. Novel deadbeat power control strategy for grid connected systems

    Directory of Open Access Journals (Sweden)

    Yousry Atia

    2015-09-01

    Full Text Available This paper introduces a novel approach for power control of three phase voltage source inverter (VSI in grid connected distribution generation system. In this approach, the control of active and reactive power is based on deadbeat control strategy. First, the difference between the reference and actual currents are introduced in different approach. Then current to power substitutions are carried out to obtain direct relationship between the required inverter voltage and instantaneous power errors. There is no need for coordinate transformation or PLL, where the required inverter voltage vector calculations carried out in α–β stationary reference frame. The proposed technique introduces two cross coupling components in the control function. Including these two components, the controller can achieve nearly zero steady-state tracking error of the controlled variables. To obtain fixed switching frequency operations, space vector modulation (SVM is used to synthesize the required inverter voltage vector and to generate the switching pulses for the VSI. The proposed strategy has the simplicity of the direct power control (DPC technique and doesn’t require any current control loops. The proposed strategy is experimentally implemented using fixed-point microcontroller. Simulation and experimental results are presented to confirm the superiority of the proposed strategy.

  5. Probabilistic analysis in normal operation of distribution system with distributed generation

    DEFF Research Database (Denmark)

    Villafafila-Robles, R.; Sumper, A.; Bak-Jensen, B.

    2011-01-01

    Nowadays, the incorporation of high levels of small-scale non-dispatchable distributed generation is leading to the transition from the traditional 'vertical' power system structure to a 'horizontally-operated' power system, where the distribution networks contain both stochastic generation...... and load. This fact increases the number of stochastic inputs and dependence structures between them need to be considered. The deterministic analysis is not enough to cope with these issues and a new approach is needed. Probabilistic analysis provides a better approach. Moreover, as distribution systems...

  6. Modern Embedded Computing Designing Connected, Pervasive, Media-Rich Systems

    CERN Document Server

    Barry, Peter

    2012-01-01

    Modern embedded systems are used for connected, media-rich, and highly integrated handheld devices such as mobile phones, digital cameras, and MP3 players. All of these embedded systems require networking, graphic user interfaces, and integration with PCs, as opposed to traditional embedded processors that can perform only limited functions for industrial applications. While most books focus on these controllers, Modern Embedded Computing provides a thorough understanding of the platform architecture of modern embedded computing systems that drive mobile devices. The book offers a comprehen

  7. The THUDSOS Distributed Operating System

    Institute of Scientific and Technical Information of China (English)

    廖先Zhi; 刘旭峰; 等

    1991-01-01

    The THUDSOS is a distributed operating system modeled as an abstract machine which provides decentralized control,transparency,availability,and reliability,as welol as a good degree of autonomy at each node,that makes our distributed system usable.Our operating system supports transparent access to data through network wide filesystem.The simultaneous access to any device is discussed for the case when the peripherals are treated as files.This operating system allows spawning of parallel application programs to solve problems in the fields,such as numerical analysis and artificial intelligence.

  8. Reactive power balance in a distribution network with wind farms and CHPS

    DEFF Research Database (Denmark)

    Lund, Torsten; Nielsen, John Eli; Hylle, Per

    2007-01-01

    In Denmark, a large part of the electricity is generated by wind turbines and combined heat and power plants. Most of them are connected to the distribution systems. In periods with high wind speeds, large flows of reactive power have been observed between the 150kV and the 60 kV systems. The tra......In Denmark, a large part of the electricity is generated by wind turbines and combined heat and power plants. Most of them are connected to the distribution systems. In periods with high wind speeds, large flows of reactive power have been observed between the 150kV and the 60 kV systems....... The transfer of reactive power reduces the capacity of the lines, causes thermal losses and can in some cases reduce the voltage stability margin of the system. To identify the origin of the problem, an actual distribution system with a high penetration of wind power and distributed generation has been...

  9. Systemic Analysis of Food Supply and Distribution Systems in City-Region Systems—An Examination of FAO’s Policy Guidelines towards Sustainable Agri-Food Systems

    Directory of Open Access Journals (Sweden)

    Vanessa Armendáriz

    2016-12-01

    Full Text Available The world is continuously transforming to supply growing cities and urbanization processes are still driving important changes in our current food systems. Future sustainability constraints are emphasizing that Food Supply and Distribution Systems (FSDS are deeply embedded in city-region systems with specific technical and socio-ecological characteristics. This paper aims to provide a systemic understanding on FSDS focusing the integration of urban and rural structures considering the system biophysical boundaries and societal targets. A qualitative framework model, based on the Food and Agriculture Organization of the United Nations (FAO’s FSDS literature, has been developed by using Systems Thinking (ST and System Dynamics (SD approaches. The model analysis suggested that to increase sustainability and resilience of food systems large emphasis has to be maintained on: (i estimation of local territorial carrying capacities; (ii land use planning to enhance connections among rural supplies and city needs; (iii city policies, to regulate emergent market size and local scale of production; (iv technological efficiency at farm, distribution and market levels; (v urban, peri-urban and rural functional linkages that considers social metabolic balances; (vi rural development as a core point for building sustainable food systems and counteracting the urbanization growth. These key areas are relevant to test new paths of cities-regions reconfiguration towards the transition to resilient agri-food systems.

  10. Strategy Guideline. Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-06-01

    This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  11. A Desktop Screen Sharing System based on Various Connection Methods

    Science.gov (United States)

    Negishi, Yuya; Kawaguchi, Nobuo

    Recently it became very common to use information devices such as PCs during presentations and discussions. In these situations, a need arises for techniques that allow a smooth switch of presenters without changing cables, or an easy screen sharing in case of remote videoconferences. In this paper, we propose a desktop screen sharing system that can be used for such purposes and situations. For that, we designed an automatic control of connections in the VNC system that can be operated remotely over the network. We also suggested an interface that assigns a role such as “Screen sender" or “Screen receiver" to each terminal. In the proposed system, while sharing a screen between multiple terminals, one can easily display and browse the screen without having to understand how the others are connected. We also implemented a “role card" using contactless IC card, where roles are assigned only by placing the card in the IC reader.

  12. Integrating Resources into Curriculum with the Systems Connect Planning Guide

    Science.gov (United States)

    Oshry, A.; Bean, J. R.

    2017-12-01

    A broadly applicable and guided approach for planning curriculum and instruction around new academic standards or initiatives is critical for implementation success. Curriculum and assessment differs across schools and districts, so built-in adaptability is important for maximal adoption and ease of use by educators. The Systems Connect Planning Guide directs the flow of instruction for building conceptual links between topics in a unit/curriculum through critical vetting and integration of relevant resources. This curricular template is flexible for use in any setting or subject area, and ensures applicability, high impact and responsiveness to academic standards while providing inquiry-based, real-world investigations and action that incorporate authentic research and data. These needs are what informed the creation of the three components of the planning guide:• Curriculum Anchor: alignment with academic standards & learning outcomes and setting the context of the topic• Issues Investigations: informing how students explore topics, and incorporate authentic research and data into learning progressions• Civic Action: development of how students could apply their knowledgeThe Planning Guide also incorporates criteria from transdisciplinary practices, cross-cutting concepts, and organizational charts for outlining guiding questions and conceptual links embedded in the guide. Integration of experiential learning and real-world connections into curricula is important for proficiency and deeper understanding of content, replacing discrete, stand-alone experiences which are not explicitly connected. Rather than information being dispelled through individual activities, relying on students to make the connections, intentionally documenting explicit connections provides opportunities to foster deeper understanding by building conceptual links between topics, which is how fundamental knowledge about earth and living systems is gained. Through the critical vetting

  13. Coordinated Optimization of Distributed Energy Resources and Smart Loads in Distribution Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui; Zhang, Yingchen

    2016-08-01

    Distributed energy resources (DERs) and smart loads have the potential to provide flexibility to the distribution system operation. A coordinated optimization approach is proposed in this paper to actively manage DERs and smart loads in distribution systems to achieve the optimal operation status. A three-phase unbalanced Optimal Power Flow (OPF) problem is developed to determine the output from DERs and smart loads with respect to the system operator's control objective. This paper focuses on coordinating PV systems and smart loads to improve the overall voltage profile in distribution systems. Simulations have been carried out in a 12-bus distribution feeder and results illustrate the superior control performance of the proposed approach.

  14. Equilibrium distribution function in collisionless systems

    International Nuclear Information System (INIS)

    Pergamenshchik, V.M.

    1988-01-01

    Collisionless systems of a large number of N particles interacting by Coulomb forces are widely spread in cosmic and laboratory plasma. A statistical theory of equilibrium state of collisionless Coulomb systems which evolution obeys Vlasov equation is proposed. The developed formalism permits a sequential consideration of such distributed in one-particle six-dimensional phase space of a system and to obtain a simple result: equilibrium distribution function has the form of Fermi-Dirac distribution and doesn't depend on initial state factors

  15. On Distributed Port-Hamiltonian Process Systems

    NARCIS (Netherlands)

    Lopezlena, Ricardo; Scherpen, Jacquelien M.A.

    2004-01-01

    In this paper we use the term distributed port-Hamiltonian Process Systems (DPHPS) to refer to the result of merging the theory of distributed Port-Hamiltonian systems (DPHS) with the theory of process systems (PS). Such concept is useful for combining the systematic interconnection of PHS with the

  16. Distributed gas sensing with optical fibre photothermal interferometry.

    Science.gov (United States)

    Lin, Yuechuan; Liu, Fei; He, Xiangge; Jin, Wei; Zhang, Min; Yang, Fan; Ho, Hoi Lut; Tan, Yanzhen; Gu, Lijuan

    2017-12-11

    We report the first distributed optical fibre trace-gas detection system based on photothermal interferometry (PTI) in a hollow-core photonic bandgap fibre (HC-PBF). Absorption of a modulated pump propagating in the gas-filled HC-PBF generates distributed phase modulation along the fibre, which is detected by a dual-pulse heterodyne phase-sensitive optical time-domain reflectometry (OTDR) system. Quasi-distributed sensing experiment with two 28-meter-long HC-PBF sensing sections connected by single-mode transmission fibres demonstrated a limit of detection (LOD) of ∼10 ppb acetylene with a pump power level of 55 mW and an effective noise bandwidth (ENBW) of 0.01 Hz, corresponding to a normalized detection limit of 5.5ppb⋅W/Hz. Distributed sensing experiment over a 200-meter-long sensing cable made of serially connected HC-PBFs demonstrated a LOD of ∼ 5 ppm with 62.5 mW peak pump power and 11.8 Hz ENBW, or a normalized detection limit of 312ppb⋅W/Hz. The spatial resolution of the current distributed detection system is limited to ∼ 30 m, but it is possible to reduce down to 1 meter or smaller by optimizing the phase detection system.

  17. Traffic Congestion Detection System through Connected Vehicles and Big Data

    OpenAIRE

    Néstor Cárdenas-Benítez; Raúl Aquino-Santos; Pedro Magaña-Espinoza; José Aguilar-Velazco; Arthur Edwards-Block; Aldo Medina Cass

    2016-01-01

    This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO2 and decreasing travel time. This system monitors, processes and stores large amounts of data, which ...

  18. A Heuristic Approach to Distributed Generation Source Allocation for Electrical Power Distribution Systems

    Directory of Open Access Journals (Sweden)

    M. Sharma

    2010-12-01

    Full Text Available The recent trends in electrical power distribution system operation and management are aimed at improving system conditions in order to render good service to the customer. The reforms in distribution sector have given major scope for employment of distributed generation (DG resources which will boost the system performance. This paper proposes a heuristic technique for allocation of distribution generation source in a distribution system. The allocation is determined based on overall improvement in network performance parameters like reduction in system losses, improvement in voltage stability, improvement in voltage profile. The proposed Network Performance Enhancement Index (NPEI along with the heuristic rules facilitate determination of feasible location and corresponding capacity of DG source. The developed approach is tested with different test systems to ascertain its effectiveness.

  19. Experimental evaluation of 8kW grid-connected photovoltaic system in Egypt

    OpenAIRE

    Elkholy, A.; Fahmy, F.H.; Abou El-Ela, A.A.; Nafeh, Abd El-Shafy A.; Spea, S.R.

    2016-01-01

    An experimental observation study of 8 kW grid-connected photovoltaic (PV) system that is installed at Electronics Research Institute (ERI), Giza, Egypt (Latitude 30.04°N, Longitude 31.21°E), is presented. This study includes the quality of the electrical power generated and injected into the network. The considered system consists of 28 × 295 Wp multicrystalline PV modules, StecaGrid three-phase 8 kW grid-connected inverter and a Solar-Log 300 PM+ for data acquisition and remote monitoring. ...

  20. Review on Islanding Operation of Distribution System with Distributed Generation

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2011-01-01

    The growing environmental concern and various benefits of distributed generation (DG) have resulted in significant penetration of DG in many distribution systems worldwide. One of the major expected benefits of DG is the improvement in the reliability of power supply by supplying load during power...... outage by operating in an island mode. However, there are many challenges to overcome before islanding operation of a distribution system with DG can become a viable solution in future. This paper reviews some of the major challenges with islanding operation and explores some possible solutions...