WorldWideScience

Sample records for distinct ecg patterns

  1. New methodologies for measuring Brugada ECG patterns cannot differentiate the ECG pattern of Brugada syndrome from Brugada phenocopy.

    Science.gov (United States)

    Gottschalk, Byron H; Garcia-Niebla, Javier; Anselm, Daniel D; Jaidka, Atul; De Luna, Antoni Bayés; Baranchuk, Adrian

    2016-01-01

    Brugada phenocopies (BrP) are clinical entities characterized by ECG patterns that are identical to true Brugada syndrome (BrS), but are elicited by various clinical circumstances. A recent study demonstrated that the patterns of BrP and BrS are indistinguishable under the naked eye, thereby validating the concept that the patterns are identical. The aim of our study was to determine whether recently developed ECG criteria would allow for discrimination between type-2 BrS ECG pattern and type-2 BrP ECG pattern. Ten ECGs from confirmed BrS (aborted sudden death, transformation into type 1 upon sodium channel blocking test and/or ventricular arrhythmias, positive genetics) cases and 9 ECGs from confirmed BrP were included in the study. Surface 12-lead ECGs were scanned, saved in JPEG format for blind measurement of two values: (i) β-angle; and (ii) the base of the triangle. Cut-off values of ≥58° for the β-angle and ≥4mm for the base of the triangle were used to determine the BrS ECG pattern. Mean values for the β-angle in leads V1 and V2 were 66.7±25.5 and 55.4±28.1 for BrS and 54.1±26.5 and 43.1±16.1 for BrP respectively (p=NS). Mean values for the base of the triangle in V1 and V2 were 7.5±3.9 and 5.7±3.9 for BrS and 5.6±3.2 and 4.7±2.7 for BrP respectively (p=NS). The β-angle had a sensitivity of 60%, specificity of 78% (LR+ 2.7, LR- 0.5). The base of the triangle had a sensitivity of 80%, specificity of 40% (LR+ 1.4, LR- 0.5). New ECG criteria presented relatively low sensitivity and specificity, positive and negative predictive values to discriminate between BrS and BrP ECG patterns, providing further evidence that the two patterns are identical. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Methods for Improving the Diagnosis of a Brugada ECG Pattern.

    Science.gov (United States)

    Gottschalk, Byron H; Garcia-Niebla, Javier; Anselm, Daniel D; Glover, Benedict; Baranchuk, Adrian

    2016-03-01

    Brugada syndrome (BrS) is an inherited channelopathy that predisposes individuals to malignant arrhythmias and can lead to sudden cardiac death. The condition is characterized by two electrocardiography (ECG) patterns: the type-1 or "coved" ECG and the type-2 or "saddleback" ECG. Although the type-1 Brugada ECG pattern is diagnostic for the condition, the type-2 Brugada ECG pattern requires differential diagnosis from conditions that produce a similar morphology. In this article, we present a case that is suspicious but not diagnostic for BrS and discuss the application of ECG methodologies for increasing or decreasing suspicion for a diagnosis of BrS. © 2015 Wiley Periodicals, Inc.

  3. Identifying drug-induced repolarization abnormalities from distinct ECG patterns in congenital long QT syndrome: a study of sotalol effects on T-wave morphology

    DEFF Research Database (Denmark)

    Graff, Claus; Andersen, Mads P; Xue, Joel Q

    2009-01-01

    BACKGROUND: The electrocardiographic QT interval is used to identify drugs with potential harmful effects on cardiac repolarization in drug trials, but the variability of the measurement can mask drug-induced ECG changes. The use of complementary electrocardiographic indices of abnormal repolariz......BACKGROUND: The electrocardiographic QT interval is used to identify drugs with potential harmful effects on cardiac repolarization in drug trials, but the variability of the measurement can mask drug-induced ECG changes. The use of complementary electrocardiographic indices of abnormal...... are typical ECG patterns in LQT2. Blinded to labels, the new morphology measures were tested in a third group of 39 healthy subjects receiving sotalol. Over 3 days the sotalol group received 0, 160 and 320 mg doses, respectively, and a 12-lead Holter ECG was recorded for 22.5 hours each day. Drug...... with QTcF, p ECG patterns in LQT2 carriers effectively quantified repolarization changes induced by sotalol. Further studies are needed to validate whether this measure has...

  4. Resting ECG findings in elite football players.

    Science.gov (United States)

    Bohm, Philipp; Ditzel, Roman; Ditzel, Heribert; Urhausen, Axel; Meyer, Tim

    2013-01-01

    The purpose of the study was to evaluate ECG abnormalities in a large sample of elite football players. Data from 566 elite male football players (57 of them of African origin) above 16 years of age were screened retrospectively (age: 20.9 ± 5.3 years; BMI: 22.9 ± 1.7 kg · m(-2), training history: 13.8 ± 4.7 years). The resting ECGs were analysed and classified according to the most current ECG categorisation of the European Society of Cardiology (ESC) (2010) and a classification of Pelliccia et al. (2000) in order to assess the impact of the new ESC-approach. According to the classification of Pelliccia, 52.5% showed mildly abnormal ECG patterns and 12% were classified as distinctly abnormal ECG patterns. According to the classification of the ESC, 33.7% showed 'uncommon ECG patterns'. Short-QT interval was the most frequent ECG pattern in this group (41.9%), followed by a shortened PR-interval (19.9%). When assessed with a QTc cut-off-point of 340 ms (instead of 360 ms), only 22.2% would have had 'uncommon ECG patterns'. Resting ECG changes amongst elite football players are common. Adjustment of the ESC criteria by adapting proposed time limits for the ECG (e.g. QTc, PR) should further reduce the rate of false-positive results.

  5. Efficacy and safety of dextrose-insulin in unmasking non-diagnostic Brugada ECG patterns.

    Science.gov (United States)

    Velázquez-Rodríguez, Enrique; Rodríguez-Piña, Horacio; Pacheco-Bouthillier, Alex; Jiménez-Cruz, Marcelo Paz

    Typical diagnostic, coved-type 1, Brugada ECG patterns fluctuate spontaneously over time with a high proportion of non-diagnostic ECG patterns. Insulin modulates ion transport mechanisms and causes hyperpolarization of the resting potential. We report our experience with unmasking J-ST changes in response to a dextrose-insulin test. Nine patients, mean age 40.5±19.4years (range: 15-65years), presented initially with a non-diagnostic ECG pattern, which was suggestive of Brugada syndrome (group I). They were compared with 10 patients with normal ECG patterns (group II). Participants received an infusion of 50g of 50% dextrose, followed by 10IU of intravenous regular insulin. Positive changes were defined by conversion to a diagnostic ECG pattern. The dextrose-insulin test was positive in six of seven (85.7%) patients (kappa 0.79, p=0.02) that was confirmed with a pharmacologic test (kappa 1, p=0.003). One had an inconclusive test, and two with a negative test had an early repolarization ECG pattern. All subjects in group II had a negative test (pECG patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Usefulness of ST elevation score by using vector-projected virtual 187-channel ECG for risk stratification in patients with Brugada-type ECG pattern

    Directory of Open Access Journals (Sweden)

    Shoko Ishikawa

    2012-08-01

    Conclusion: The ST elevation score in VP-ECG objectively documented the degree of ST elevation in surface ECG in Brugada-type ECG patterns. The ST-elevation score might be useful for risk stratification in patients with asymptomatic Brugada syndrome.

  7. Is screening for abnormal ECG patterns justified in long-term follow-up of childhood cancer survivors treated with anthracyclines?

    NARCIS (Netherlands)

    Pourier, M.S.; Mavinkurve-Groothuis, A.M.C.; Loonen, J.J.; Bokkerink, J.P.M.; Roeleveld, N.; Beer, G.; Bellersen, L.; Kapusta, L.

    2017-01-01

    BACKGROUND: ECG and echocardiography are noninvasive screening tools to detect subclinical cardiotoxicity in childhood cancer survivors (CCSs). Our aims were as follows: (1) assess the prevalence of abnormal ECG patterns, (2) determine the agreement between abnormal ECG patterns and

  8. Specificity of elevated intercostal space ECG recording for the type 1 Brugada ECG pattern

    DEFF Research Database (Denmark)

    Holst, Anders G; Tangø, Mogens; Batchvarov, Velislav

    2012-01-01

    Right precordial (V1-3) elevated electrode placement ECG (EEP-ECG) is often used in the diagnosis of Brugada syndrome (BrS). However, the specificity of this has only been studied in smaller studies in Asian populations. We aimed to study this in a larger European population.......Right precordial (V1-3) elevated electrode placement ECG (EEP-ECG) is often used in the diagnosis of Brugada syndrome (BrS). However, the specificity of this has only been studied in smaller studies in Asian populations. We aimed to study this in a larger European population....

  9. Common ECG Lead Placement Errors. Part I: Limb Lead Reversals

    Directory of Open Access Journals (Sweden)

    Allison V. Rosen

    2015-10-01

    Full Text Available Background: Electrocardiography (ECG is a very useful diagnostic tool. However, errors in placement of ECG leads can create artifacts, mimic pathologies, and hinder proper ECG interpretation. It is important for members of the health care team to be able to recognize the common patterns resulting from lead placement errors. Methods: 12-lead ECGs were recorded in a single male healthy subject in his mid 20s. Six different limb lead reversals were compared to ECG recordings from correct lead placement. Results: Classic ECG patterns were observed when leads were reversed. Methods of discriminating these ECG patterns from true pathologic findings were described. Conclusion: Correct recording and interpretation of ECGs is key to providing optimal patient care. It is therefore crucial to be able to recognize common ECG patterns that are indicative of lead reversals.

  10. An integrated on-line system for the evaluation of ECG patterns with a small process computer

    International Nuclear Information System (INIS)

    Schoffa, G.; Eggenberger, O.; Krueger, G.; Karlsruhe Univ.

    1975-01-01

    This paper describes an on-line system for ECG processing with a small computer (8K memory) and a magnetic tape cassette for mass storage capable to evaluate 30 ECG patterns in a twelfe lead system per day. The use of a small computer was possible by a compact and easy-to-handle operating system and space-saving programs. The system described was specifically intended for use in smaller hospitals with a low number of ECG's per day which do not allow an economic operation of greater DP installations. The economy calculations, based on the 'Break-even-point method' with special regard to the installations, mainennance and personnel costs already grant an economic operation of a small computer at a rate of 5 ECG's per day. (orig.) [de

  11. Coronary artery calcification and ECG pattern of left ventricular hypertrophy or strain identify different healthy individuals at risk

    DEFF Research Database (Denmark)

    Diederichsen, Søren Zöga; Gerke, Oke; Olsen, Michael Hecht

    2013-01-01

    PURPOSE:: To improve risk stratification for development of ischaemic heart disease, several markers have been proposed. Both the presence of coronary artery calcification (CAC) and ECG pattern of left ventricular hypertrophy/strain have been shown to provide independent prognostic information....... In this study, we investigated the association between established risk factors, ECG measurements and the presence of coronary artery calcification. METHOD:: A random sample of healthy men and women aged 50 or 60 years were invited to the screening study. Established risk factors were measured. A noncontrast...... computed tomographic (CT) scan was performed to assess the CAC score. ECG analysis included left ventricular hypertrophy (LVH) using the Sokolow-Lyon criteria and the Cornell voltage × QRS duration product, and strain pattern based on ST segment depression and T-wave abnormalities. The association between...

  12. Human Identification by Cross-Correlation and Pattern Matching of Personalized Heartbeat: Influence of ECG Leads and Reference Database Size.

    Science.gov (United States)

    Jekova, Irena; Krasteva, Vessela; Schmid, Ramun

    2018-01-27

    Human identification (ID) is a biometric task, comparing single input sample to many stored templates to identify an individual in a reference database. This paper aims to present the perspectives of personalized heartbeat pattern for reliable ECG-based identification. The investigations are using a database with 460 pairs of 12-lead resting electrocardiograms (ECG) with 10-s durations recorded at time-instants T1 and T2 > T1 + 1 year. Intra-subject long-term ECG stability and inter-subject variability of personalized PQRST (500 ms) and QRS (100 ms) patterns is quantified via cross-correlation, amplitude ratio and pattern matching between T1 and T2 using 7 features × 12-leads. Single and multi-lead ID models are trained on the first 230 ECG pairs. Their validation on 10, 20, ... 230 reference subjects (RS) from the remaining 230 ECG pairs shows: (i) two best single-lead ID models using lead II for a small population RS = (10-140) with identification accuracy AccID = (89.4-67.2)% and aVF for a large population RS = (140-230) with AccID = (67.2-63.9)%; (ii) better performance of the 6-lead limb vs. the 6-lead chest ID model-(91.4-76.1)% vs. (90.9-70)% for RS = (10-230); (iii) best performance of the 12-lead ID model-(98.4-87.4)% for RS = (10-230). The tolerable reference database size, keeping AccID > 80%, is RS = 30 in the single-lead ID scenario (II); RS = 50 (6 chest leads); RS = 100 (6 limb leads), RS > 230-maximal population in this study (12-lead ECG).

  13. Clinical characteristics in genetically distinct forms of the congenital long QT syndrome

    International Nuclear Information System (INIS)

    Kawahara, Yosuke; Sawayama, Toshitami; Samukawa, Masanobu; Nezuo, Shoso; Tanaka, Junji; Suetsuna, Ryoji; Kamiyama, Norio

    1998-01-01

    The clinical characteristics in genetically distinct forms of the congenital long QT syndrome (LQTs) were examined on the balance of bilateral sympathetic nerves, and ECG findings. The subjects (mean: 19.4 years old) were three genetically distinct forms of LQTs, including 3 patients in A-family (the high risk family with sudden death), 2 patients in B-family and 3 patients in C-family. All patients met the standard diagnostic criteria according to Schwartz. As the index of the balance of bilateral sympathetic nerves, the dissociation of Tl and MIBG uptake (D) was examined and the radioactivity ratio (the A/L ratio) of anteroseptal wall to posterolateral wall was calculated. The T-wave patterns of ECG and the situation at syncope were examined. In A-family, all 3 patients showed the lowered A/L ratio, D(+), and similar T-wave patterns in ECG. The syndrome developed at exercise, and their QTc extended at exercise. In B-family, all 2 patients showed normal A/L ratio and long T-wave at QT onset, and their QTc shortened at exercise. All patients had developed syncope at rest. In C-family, all 3 patients showed a little decrease of A/L ratio and similar T-wave patterns. Their QTc extended at exercise. These results suggest that the characteristics of the sympathetic nerve balance, ECG wave patterns and the syndrome may depend on each family. (K.H.)

  14. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  15. Distinctive Left Ventricular Activations Associated With ECG Pattern in Heart Failure Patients.

    Science.gov (United States)

    Derval, Nicolas; Duchateau, Josselin; Mahida, Saagar; Eschalier, Romain; Sacher, Frederic; Lumens, Joost; Cochet, Hubert; Denis, Arnaud; Pillois, Xavier; Yamashita, Seigo; Komatsu, Yuki; Ploux, Sylvain; Amraoui, Sana; Zemmoura, Adlane; Ritter, Philippe; Hocini, Mélèze; Haissaguerre, Michel; Jaïs, Pierre; Bordachar, Pierre

    2017-06-01

    In contrast to patients with left bundle branch block (LBBB), heart failure patients with narrow QRS and nonspecific intraventricular conduction delay (NICD) display a relatively limited response to cardiac resynchronization therapy. We sought to compare left ventricular (LV) activation patterns in heart failure patients with narrow QRS and NICD to patients with LBBB using high-density electroanatomic activation maps. Fifty-two heart failure patients (narrow QRS [n=18], LBBB [n=11], NICD [n=23]) underwent 3-dimensional electroanatomic mapping with a high density of mapping points (387±349 LV). Adjunctive scar imaging was available in 37 (71%) patients and was analyzed in relation to activation maps. LBBB patients typically demonstrated (1) a single LV breakthrough at the septum (38±15 ms post-QRS onset); (2) prolonged right-to-left transseptal activation with absence of direct LV Purkinje activity; (3) homogeneous propagation within the LV cavity; and (4) latest activation at the basal lateral LV. In comparison, both NICD and narrow QRS patients demonstrated (1) multiple LV breakthroughs along the posterior or anterior fascicles: narrow QRS versus LBBB, 5±2 versus 1±1; P =0.0004; NICD versus LBBB, 4±2 versus 1±1; P =0.001); (2) evidence of early/pre-QRS LV electrograms with Purkinje potentials; (3) rapid propagation in narrow QRS patients and more heterogeneous propagation in NICD patients; and (4) presence of limited areas of late activation associated with LV scar with high interindividual heterogeneity. In contrast to LBBB patients, narrow QRS and NICD patients are characterized by distinct mechanisms of LV activation, which may predict poor response to cardiac resynchronization therapy. © 2017 American Heart Association, Inc.

  16. Pattern recognition in paediatric ecgs: the hidden secrets to clinical ...

    African Journals Online (AJOL)

    remain as important as ever, but may play only secondary roles in the diagnostic value of ... the more complex ones are best left to the experts. This article ... ECG 1 is a normal ECG of an 8-year-old child, showing sinus rhythm, a heart rate of ...

  17. Electrocardiogram (ECG Signal Modeling and Noise Reduction Using Hopfield Neural Networks

    Directory of Open Access Journals (Sweden)

    F. Bagheri

    2013-02-01

    Full Text Available The Electrocardiogram (ECG signal is one of the diagnosing approaches to detect heart disease. In this study the Hopfield Neural Network (HNN is applied and proposed for ECG signal modeling and noise reduction. The Hopfield Neural Network (HNN is a recurrent neural network that stores the information in a dynamic stable pattern. This algorithm retrieves a pattern stored in memory in response to the presentation of an incomplete or noisy version of that pattern. Computer simulation results show that this method can successfully model the ECG signal and remove high-frequency noise.

  18. Assessing ECG signal quality indices to discriminate ECGs with artefacts from pathologically different arrhythmic ECGs.

    Science.gov (United States)

    Daluwatte, C; Johannesen, L; Galeotti, L; Vicente, J; Strauss, D G; Scully, C G

    2016-08-01

    False and non-actionable alarms in critical care can be reduced by developing algorithms which assess the trueness of an arrhythmia alarm from a bedside monitor. Computational approaches that automatically identify artefacts in ECG signals are an important branch of physiological signal processing which tries to address this issue. Signal quality indices (SQIs) derived considering differences between artefacts which occur in ECG signals and normal QRS morphology have the potential to discriminate pathologically different arrhythmic ECG segments as artefacts. Using ECG signals from the PhysioNet/Computing in Cardiology Challenge 2015 training set, we studied previously reported ECG SQIs in the scientific literature to differentiate ECG segments with artefacts from arrhythmic ECG segments. We found that the ability of SQIs to discriminate between ECG artefacts and arrhythmic ECG varies based on arrhythmia type since the pathology of each arrhythmic ECG waveform is different. Therefore, to reduce the risk of SQIs classifying arrhythmic events as noise it is important to validate and test SQIs with databases that include arrhythmias. Arrhythmia specific SQIs may also minimize the risk of misclassifying arrhythmic events as noise.

  19. A model-based Bayesian framework for ECG beat segmentation

    International Nuclear Information System (INIS)

    Sayadi, O; Shamsollahi, M B

    2009-01-01

    The study of electrocardiogram (ECG) waveform amplitudes, timings and patterns has been the subject of intense research, for it provides a deep insight into the diagnostic features of the heart's functionality. In some recent works, a Bayesian filtering paradigm has been proposed for denoising and compression of ECG signals. In this paper, it is shown that this framework may be effectively used for ECG beat segmentation and extraction of fiducial points. Analytic expressions for the determination of points and intervals are derived and evaluated on various real ECG signals. Simulation results show that the method can contribute to and enhance the clinical ECG beat segmentation performance

  20. ECG strain pattern in hypertension is associated with myocardial cellular expansion and diffuse interstitial fibrosis: a multi-parametric cardiac magnetic resonance study.

    Science.gov (United States)

    Rodrigues, Jonathan C L; Amadu, Antonio Matteo; Ghosh Dastidar, Amardeep; McIntyre, Bethannie; Szantho, Gergley V; Lyen, Stephen; Godsave, Cattleya; Ratcliffe, Laura E K; Burchell, Amy E; Hart, Emma C; Hamilton, Mark C K; Nightingale, Angus K; Paton, Julian F R; Manghat, Nathan E; Bucciarelli-Ducci, Chiara

    2017-04-01

    In hypertension, the presence of left ventricular (LV) strain pattern on 12-lead electrocardiogram (ECG) carries adverse cardiovascular prognosis. The underlying mechanisms are poorly understood. We investigated whether hypertensive ECG strain is associated with myocardial interstitial fibrosis and impaired myocardial strain, assessed by multi-parametric cardiac magnetic resonance (CMR). A total of 100 hypertensive patients [50 ± 14 years, male: 58%, office systolic blood pressure (SBP): 170 ± 30 mmHg, office diastolic blood pressure (DBP): 97 ± 14 mmHg) underwent ECG and 1.5T CMR and were compared with 25 normotensive controls (46 ± 14 years, 60% male, SBP: 124 ± 8 mmHg, DBP: 76 ± 7 mmHg). Native T1 and extracellular volume fraction (ECV) were calculated with the modified look-locker inversion-recovery sequence. Myocardial strain values were estimated with voxel-tracking software. ECG strain (n = 20) was associated with significantly higher indexed LV mass (LVM) (119 ± 32 vs. 80 ± 17 g/m2, P ECG strain (n = 80). ECG strain subjects had significantly impaired circumferential strain compared with hypertensive subjects without ECG strain and controls (-15.2 ± 4.7 vs. -17.0 ± 3.3 vs. -17.3 ± 2.4%, P ECG strain subjects to hypertensive subjects with elevated LVM but no ECG strain, a significantly higher ECV (30 ± 4 vs. 28 ± 3%, P ECG strain in multivariate logistic regression analysis [odds ratio (95th confidence interval): 1.07 (1.02-1.12), P ECG strain is a marker of advanced LVH associated with increased interstitial fibrosis and associated with significant myocardial circumferential strain impairment. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  1. Matrix of regularity for improving the quality of ECGs

    International Nuclear Information System (INIS)

    Xia, Henian; Garcia, Gabriel A; Zhao, Xiaopeng; Bains, Jujhar; Wortham, Dale C

    2012-01-01

    The 12-lead electrocardiography (ECG) is the gold standard for diagnosis of abnormalities of the heart. However, the ECG is susceptible to artifacts, which may lead to wrong diagnosis and thus mistreatment. It is a clinical challenge of great significance differentiating ECG artifacts from patterns of diseases. We propose a computational framework, called the matrix of regularity, to evaluate the quality of ECGs. The matrix of regularity is a novel mechanism to fuse results from multiple tests of signal quality. Moreover, this method can produce a continuous grade, which can more accurately represent the quality of an ECG. When tested on a dataset from the Computing in Cardiology/PhysioNet Challenge 2011, the algorithm achieves up to 95% accuracy. The area under the receiver operating characteristic curve is 0.97. The developed framework and computer program have the potential to improve the quality of ECGs collected using conventional and portable devices. (paper)

  2. Unveiling the Biometric Potential of Finger-Based ECG Signals

    Science.gov (United States)

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications. PMID:21837235

  3. Unveiling the biometric potential of finger-based ECG signals.

    Science.gov (United States)

    Lourenço, André; Silva, Hugo; Fred, Ana

    2011-01-01

    The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications.

  4. ECG De-noising

    DEFF Research Database (Denmark)

    Kærgaard, Kevin; Jensen, Søren Hjøllund; Puthusserypady, Sadasivan

    2015-01-01

    Electrocardiogram (ECG) is a widely used noninvasive method to study the rhythmic activity of the heart and thereby to detect the abnormalities. However, these signals are often obscured by artifacts from various sources and minimization of these artifacts are of paramount important. This paper...... proposes two adaptive techniques, namely the EEMD-BLMS (Ensemble Empirical Mode Decomposition in conjunction with the Block Least Mean Square algorithm) and DWT-NN (Discrete Wavelet Transform followed by Neural Network) methods in minimizing the artifacts from recorded ECG signals, and compares...... their performance. These methods were first compared on two types of simulated noise corrupted ECG signals: Type-I (desired ECG+noise frequencies outside the ECG frequency band) and Type-II (ECG+noise frequencies both inside and outside the ECG frequency band). Subsequently, they were tested on real ECG recordings...

  5. Electrocardiographic patterns in African University strength and endurance athletes of Zulu descent.

    Science.gov (United States)

    Grace, J; Duvenage, E; Jordaan, J P

    2015-11-01

    There is concern over the effect of training on heart function of athletes as recorded by 12-lead electrocardiography (ECG). Although ECG abnormalities with respect to ethnic origin of black athletes from the Caribbean, West Africa and East Africa have been reported, black athletes from southern Africa, specifically participating in different sports, have never been investigated before. The purpose of this study was to analyze the ECG patterns in South African students of Zulu descent, who represented our university in boxing (endurance modality) and body building (resistance modality) at a regional level. Fifteen subjects each were assigned to an endurance (E), resistance (R) or control (C) group, respectively. ECG patterns were recorded with a 12-lead ECG. Our subjects indicated no significant differences in ECG patterns in relation to whether they participate in strength or endurance related sport. However, 80% of the endurance group and 67% of the resistance displayed ECG criteria indicative of left ventricular hypertrophy (LVH), group E displays higher R5/S1-wave voltages (E=43.3 mm; R=36.8 mm; C=37.1 mm) as well distinctly abnormal ECG patterns (E=87%; R=73%; C=53%), raising clinical suspicion of structural heart disease. Our cohort presented with non-significant, marked ST-segment elevation (53% of both the E and R groups) and inverted T-waves in 27% of the E group. Similar to findings in other ethnic Africans, a large proportion of our Zulu study population displayed ECG criteria indicative of LVH on the evidence of a marked increase of R5/S1-wave voltage and ST/T-segment changes with no differences in relation to whether they participate in strength or endurance related sport.

  6. Cohort Study of ECG Left Ventricular Hypertrophy Trajectories: Ethnic Disparities, Associations With Cardiovascular Outcomes, and Clinical Utility.

    Science.gov (United States)

    Iribarren, Carlos; Round, Alfred D; Lu, Meng; Okin, Peter M; McNulty, Edward J

    2017-10-05

    ECG left ventricular hypertrophy (LVH) is a well-known predictor of cardiovascular disease. However, no prior study has characterized patterns of presence/absence of ECG LVH ("ECG LVH trajectories") across the adult lifespan in both sexes and across ethnicities. We examined: (1) correlates of ECG LVH trajectories; (2) the association of ECG LVH trajectories with incident coronary heart disease, transient ischemic attack, ischemic stroke, hemorrhagic stroke, and heart failure; and (3) reclassification of cardiovascular disease risk using ECG LVH trajectories. We performed a cohort study among 75 412 men and 107 954 women in the Northern California Kaiser Permanente Medical Care Program who had available longitudinal exposures of ECG LVH and covariates, followed for a median of 4.8 (range ECG LVH was measured by Cornell voltage-duration product. Adverse trajectories of ECG LVH (persistent, new development, or variable pattern) were more common among blacks and Native American men and were independently related to incident cardiovascular disease with hazard ratios ranging from 1.2 for ECG LVH variable pattern and transient ischemic attack in women to 2.8 for persistent ECG LVH and heart failure in men. ECG LVH trajectories reclassified 4% and 7% of men and women with intermediate coronary heart disease risk, respectively. ECG LVH trajectories were significant indicators of coronary heart disease, stroke, and heart failure risk, independently of level and change in cardiovascular disease risk factors, and may have clinical utility. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    Science.gov (United States)

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  8. Are ECG abnormalities in Noonan syndrome characteristic for the syndrome?

    Science.gov (United States)

    Raaijmakers, R; Noordam, C; Noonan, J A; Croonen, E A; van der Burgt, C J A M; Draaisma, J M T

    2008-12-01

    Of all patients with Noonan syndrome, 50-90% have one or more congenital heart defects. The most frequent occurring are pulmonary stenosis (PS) and hypertrophic cardiomyopathy. The electrocardiogram (ECG) of a patient with Noonan syndrome often shows a characteristic pattern, with a left axis deviation, abnormal R/S ratio over the left precordium, and an abnormal Q wave. The objective of this study was to determine if these ECG characteristics are an independent feature of the Noonan syndrome or if they are related to the congenital heart defect. A cohort study was performed with 118 patients from two university hospitals in the United States and in The Netherlands. All patients were diagnosed with definite Noonan syndrome and had had an ECG and echocardiography. Sixty-nine patients (58%) had characteristic abnormalities of the ECG. In the patient group without a cardiac defect (n = 21), ten patients had a characteristic ECG abnormality. There was no statistical relationship between the presence of a characteristic ECG abnormality and the presence of a cardiac defect (p = 0.33). Patients with hypertrophic cardiomyopathy had more ECG abnormalities in total (p = 0.05), without correlation with a specific ECG abnormality. We conclude that the ECG features in patients with Noonan syndrome are characteristic for the syndrome and are not related to a specific cardiac defect. An ECG is very useful in the diagnosis of Noonan syndrome; every child with a Noonan phenotype should have an ECG and echocardiogram for evaluation.

  9. Global Ischemia ECG pattern for diagnosis of acute left main occlusion: prevalence and associated mortality in patients with suspected acute myocardial infarction

    DEFF Research Database (Denmark)

    Stengaard, Carsten; Sørensen, Jacob Thorsted; Andersen, M.P.

    2011-01-01

    .J. Terkelsen2, 1Aarhus University Hospital, Aarhus, Department of medicine and Cardiology A - Aarhus - Denmark, 2Aarhus University Hospital, Skejby, Department of Cardiology - Aarhus - Denmark, 3Aalborg University, Department of Health Science and Technology - Aalborg - Denmark, 4Tampere University Hospital...... ischemia ECG pattern (GIP) has been proposed for diagnosis of acute left main stem (LM) occlusion. The GIP is defined by ST-elevation of 1mm in lead aVR and ST-depression of 0.5mm in seven or more ECG leads. Previous studies focus on the sensitivity of GIP in patients with confirmed LM occlusion. We...

  10. WaveformECG: A Platform for Visualizing, Annotating, and Analyzing ECG Data.

    Science.gov (United States)

    Winslow, Raimond L; Granite, Stephen; Jurado, Christian

    2016-01-01

    The electrocardiogram (ECG) is the most commonly collected data in cardiovascular research because of the ease with which it can be measured and because changes in ECG waveforms reflect underlying aspects of heart disease. Accessed through a browser, WaveformECG is an open source platform supporting interactive analysis, visualization, and annotation of ECGs.

  11. [ECG for non-competitive sports in childhood: strengths and disputes].

    Science.gov (United States)

    Poggi, Elena; Giannattasio, Alessandro; Bolloli, Sara; Beccaria, Andrea; Mezzano, Paola; Rocca, Paola; Del Vecchio, Cecilia

    2016-11-01

    Sport is very important for health promotion and conservation. Active lifestyle and regular exercise reduce cardiovascular disease incidence. The Italian Ministry of Health issued the Law Decree no. 243 (10/18/2014) concerning "guidelines for certification about non-competitive sports" to promote safety in sports. This regulation defines the activities for which a certificate is required, the professional actors involved and the clinical exams to be performed according to the patient's health status. In particular, the Law Decree recommends to perform an electrocardiogram (ECG) "at least once in a lifetime", introducing much greater news into pediatric practice. We proposed a survey evaluating frequency of ECG implementation for non-competitive sports and cardiovascular diseases incidence was administered to 7 Ligurian pediatricians. The number of ECG/year for pediatrician increased from 10 ECG/year to 50 ECG/year with an indication of suitability to non-competitive sports. One case of QT prolongation and 2 cases of type 1 Brugada ECG pattern were diagnosed. In addition, 3 patients had an atrial septal defect and 3 children had a ventricular septal defect. Forty-three percent of the pediatricians considered useful performing the ECG. ECG in children has enhanced the positive effects on the community health. However, it remains to be defined in agreement with scientific societies the age at which to perform ECG, the sports for which ECG is required and the cost-benefit ratio for the National Health System and families.

  12. Deep Arm/Ear-ECG Image Learning for Highly Wearable Biometric Human Identification.

    Science.gov (United States)

    Zhang, Qingxue; Zhou, Dian

    2018-01-01

    In this study, to advance smart health applications which have increasing security/privacy requirements, we propose a novel highly wearable ECG-based user identification system, empowered by both non-standard convenient ECG lead configurations and deep learning techniques. Specifically, to achieve a super wearability, we suggest situating all the ECG electrodes on the left upper-arm, or behind the ears, and successfully obtain weak but distinguishable ECG waveforms. Afterwards, to identify individuals from weak ECG, we further present a two-stage framework, including ECG imaging and deep feature learning/identification. In the former stage, the ECG heartbeats are projected to a 2D state space, to reveal heartbeats' trajectory behaviors and produce 2D images by a split-then-hit method. In the second stage, a convolutional neural network is introduced to automatically learn the intricate patterns directly from the ECG image representations without heavy feature engineering, and then perform user identification. Experimental results on two acquired datasets using our wearable prototype, show a promising identification rate of 98.4% (single-arm-ECG) and 91.1% (ear-ECG), respectively. To the best of our knowledge, it is the first study on the feasibility of using single-arm-ECG/ear-ECG for user identification purpose, which is expected to contribute to pervasive ECG-based user identification in smart health applications.

  13. ECG Wave-Maven: An Internet-based Electrocardiography Self-Assessment Program for Students and Clinicians

    Directory of Open Access Journals (Sweden)

    Ary L. Goldberger

    2003-02-01

    Full Text Available Purpose: To create a multimedia internet-based ECG teaching tool, with the ability to rapidly incorporate new clinical cases. Method: We created ECG Wave-Maven (http://ecg.bidmc.harvard.edu, a novel teaching tool with a direct link to an institution-wide clinical repository. We analyzed usage data from the web between December, 2000 and May 2002. Results: In 17 months, there have been 4105 distinct uses of the program. A majority of users are physicians or medical students (2605, 63%, and almost half report use as an educational tool. Conclusions: The internet offers an opportunity to provide easily-expandable, open access resources for ECG pedagogy which may be used to complement traditional methods of instruction

  14. ECG Wave-Maven: An Internet-based Electrocardiography Self-Assessment Program for Students and Clinicians.

    Science.gov (United States)

    McClennen, Seth; Nathanson, Larry A; Safran, Charles; Goldberger, Ary L

    2003-12-01

    To create a multimedia internet-based ECG teaching tool, with the ability to rapidly incorporate new clinical cases. We created ECG Wave-Maven ( http://ecg.bidmc.harvard.edu ), a novel teaching tool with a direct link to an institution-wide clinical repository. We analyzed usage data from the web between December, 2000 and May 2002. In 17 months, there have been 4105 distinct uses of the program. A majority of users are physicians or medical students (2605, 63%), and almost half report use as an educational tool. The internet offers an opportunity to provide easily-expandable, open access resources for ECG pedagogy which may be used to complement traditional methods of instruction.

  15. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs.

    Directory of Open Access Journals (Sweden)

    Emily C Hodkinson

    2016-04-01

    Full Text Available INTRODUCTIONThe resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters.METHODS and RESULTSHolter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modelling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters.CONCLUSIONSHere we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic – environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease.

  16. Improving ECG Services at a Children’s Hospital: Implementation of a Digital ECG System

    Directory of Open Access Journals (Sweden)

    Frank A. Osei

    2015-01-01

    Full Text Available Background. The use of digital ECG software and services is becoming common. We hypothesized that the introduction of a completely digital ECG system would increase the volume of ECGs interpreted at our children’s hospital. Methods. As part of a hospital wide quality improvement initiative, a digital ECG service (MUSE, GE was implemented at the Children’s Hospital at Montefiore in June 2012. The total volume of ECGs performed in the first 6 months of the digital ECG era was compared to 18 months of the predigital era. Predigital and postdigital data were compared via t-tests. Results. The mean ECGs interpreted per month were 53 ± 16 in the predigital era and 216 ± 37 in the postdigital era (p<0.001, a fourfold increase in ECG volume after introduction of the digital system. There was no significant change in inpatient or outpatient service volume during that time. The mean billing time decreased from 21 ± 27 days in the postdigital era to 12 ± 5 days in the postdigital era (p<0.001. Conclusion. Implementation of a digital ECG system increased the volume of ECGs officially interpreted and reported.

  17. ECG Electrocardiogram (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español ECG (Electrocardiogram) KidsHealth / For Parents / ECG (Electrocardiogram) Print en ... whether there is any damage. How Is an ECG Done? There is nothing painful about getting an ...

  18. Multi-purpose ECG telemetry system.

    Science.gov (United States)

    Marouf, Mohamed; Vukomanovic, Goran; Saranovac, Lazar; Bozic, Miroslav

    2017-06-19

    The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device's mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject's chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal's abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results

  19. A cancelable biometric scheme based on multi-lead ECGs.

    Science.gov (United States)

    Peng-Tzu Chen; Shun-Chi Wu; Jui-Hsuan Hsieh

    2017-07-01

    Biometric technologies offer great advantages over other recognition methods, but there are concerns that they may compromise the privacy of individuals. In this paper, an electrocardiogram (ECG)-based cancelable biometric scheme is proposed to relieve such concerns. In this scheme, distinct biometric templates for a given beat bundle are constructed via "subspace collapsing." To determine the identity of any unknown beat bundle, the multiple signal classification (MUSIC) algorithm, incorporating a "suppression and poll" strategy, is adopted. Unlike the existing cancelable biometric schemes, knowledge of the distortion transform is not required for recognition. Experiments with real ECGs from 285 subjects are presented to illustrate the efficacy of the proposed scheme. The best recognition rate of 97.58 % was achieved under the test condition N train = 10 and N test = 10.

  20. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2007-01-01

    Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. (orig.)

  1. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG.

    Science.gov (United States)

    Lee, Kwang Jin; Lee, Boreom

    2016-07-01

    Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.

  2. ECG signal processing

    NARCIS (Netherlands)

    2009-01-01

    A system extracts an ECG signal from a composite signal (308) representing an electric measurement of a living subject. Identification means (304) identify a plurality of temporal segments (309) of the composite signal corresponding to a plurality of predetermined segments (202,204,206) of an ECG

  3. The acquisition and retention of ECG interpretation skills after a standardized web-based ECG tutorial

    DEFF Research Database (Denmark)

    Rolskov Bojsen, Signe; Räder, Sune Bernd Emil Werner; Holst, Anders Gaardsdal

    2015-01-01

    BACKGROUND: Electrocardiogram (ECG) interpretation is of great importance for patient management. However, medical students frequently lack proficiency in ECG interpretation and rate their ECG training as inadequate. Our aim was to examine the effect of a standalone web-based ECG tutorial...... and to assess the retention of skills using multiple follow-up intervals. METHODS: 203 medical students were included in the study. All participants completed a pre-test, an ECG tutorial, and a post-test. The participants were also randomised to complete a retention-test after short (2-4 weeks), medium (10.......6), respectively). When comparing the pre-test to retention-test delta scores, junior students had learned significantly more than senior students (junior students improved 10.7 points and senior students improved 4.7 points, p = 0.003). CONCLUSION: A standalone web-based ECG tutorial can be an effective means...

  4. MYBPC3 hypertrophic cardiomyopathy can be detected by using advanced ECG in children and young adults.

    Science.gov (United States)

    Fernlund, E; Liuba, P; Carlson, J; Platonov, P G; Schlegel, T T

    2016-01-01

    The conventional ECG is commonly used to screen for hypertrophic cardiomyopathy (HCM), but up to 25% of adults and possibly larger percentages of children with HCM have no distinctive abnormalities on the conventional ECG, whereas 5 to 15% of healthy young athletes do. Recently, a 5-min resting advanced 12-lead ECG test ("A-ECG score") showed superiority to pooled criteria from the strictly conventional ECG in correctly identifying adult HCM. The purpose of this study was to evaluate whether in children and young adults, A-ECG scoring could detect echocardiographic HCM associated with the MYBPC3 genetic mutation with greater sensitivity than conventional ECG criteria and distinguish healthy young controls and athletes from persons with MYBPC3 HCM with greater specificity. Five-minute 12-lead ECGs were obtained from 15 young patients (mean age 13.2years, range 0-30years) with MYBPC3 mutation and phenotypic HCM. The conventional and A-ECG results of these patients were compared to those of 198 healthy children and young adults (mean age 13.2, range 1month-30years) with unremarkable echocardiograms, and to those of 36 young endurance-trained athletes, 20 of whom had athletic (physiologic) left ventricular hypertrophy. Compared with commonly used, age-specific pooled criteria from the conventional ECG, a retrospectively generated A-ECG score incorporating results from just 2 derived vectorcardiographic parameters (spatial QRS-T angle and the change in the vectorcardiographic QRS azimuth angle from the second to the third eighth of the QRS interval) increased the sensitivity of ECG for identifying MYBPC3 HCM from 46% to 87% (pyoung endurance-trained athletes (100% vs. 69% for conventional ECG criteria, pyoung adults, a 2-parameter 12-lead A-ECG score is retrospectively significantly more sensitive and specific than pooled, age-specific conventional ECG criteria for detecting MYBPC3-HCM and in distinguishing such patients from healthy controls, including endurance

  5. Recognition of distinctive patterns of gallium-67 distribution in sarcoidosis

    International Nuclear Information System (INIS)

    Sulavik, S.B.; Spencer, R.P.; Weed, D.A.; Shapiro, H.R.; Shiue, S.T.; Castriotta, R.J.

    1990-01-01

    Assessment of gallium-67 ( 67 Ga) uptake in the salivary and lacrimal glands and intrathoracic lymph nodes was made in 605 consecutive patients including 65 with sarcoidosis. A distinctive intrathoracic lymph node 67 Ga uptake pattern, resembling the Greek letter lambda, was observed only in sarcoidosis (72%). Symmetrical lacrimal gland and parotid gland 67 Ga uptake (panda appearance) was noted in 79% of sarcoidosis patients. A simultaneous lambda and panda pattern (62%) or a panda appearance with radiographic bilateral, symmetrical, hilar lymphadenopathy (6%) was present only in sarcoidosis patients. The presence of either of these patterns was particularly prevalent in roentgen Stages I (80%) or II (74%). We conclude that simultaneous (a) lambda and panda images, or (b) a panda image with bilateral symmetrical hilar lymphadenopathy on chest X-ray represent distinctive patterns which are highly specific for sarcoidosis, and may obviate the need for invasive diagnostic procedures

  6. Biometric security based on ECG

    NARCIS (Netherlands)

    Ma, L.; Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Recently the electrocardiogram (ECG) has been proposed as a novel biometric. This paper aims to construct a reliable ECG verification system, in terms of privacy protection. To this end, an improved expression to estimate the capacity in the autocorrelation (AC) of the ECG is derived, which not only

  7. Competency in ECG Interpretation Among Medical Students

    Science.gov (United States)

    Kopeć, Grzegorz; Magoń, Wojciech; Hołda, Mateusz; Podolec, Piotr

    2015-01-01

    Background Electrocardiogram (ECG) is commonly used in diagnosis of heart diseases, including many life-threatening disorders. We aimed to assess skills in ECG interpretation among Polish medical students and to analyze the determinants of these skills. Material/Methods Undergraduates from all Polish medical schools were asked to complete a web-based survey containing 18 ECG strips. Questions concerned primary ECG parameters (rate, rhythm, and axis), emergencies, and common ECG abnormalities. Analysis was restricted to students in their clinical years (4th–6th), and students in their preclinical years (1st–3rd) were used as controls. Results We enrolled 536 medical students (females: n=299; 55.8%), aged 19 to 31 (23±1.6) years from all Polish medical schools. Most (72%) were in their clinical years. The overall rate of good response was better in students in years 4th–5th than those in years 1st–3rd (66% vs. 56%; pECG interpretation was higher in students who reported ECG self-learning (69% vs. 62%; pECG classes (66% vs. 66%; p=0.99). On multivariable analysis (pECG interpretation. Conclusions Polish medical students in their clinical years have a good level of competency in interpreting the primary ECG parameters, but their ability to recognize ECG signs of emergencies and common heart abnormalities is low. ECG interpretation skills are determined by self-education but not by attendance at regular ECG classes. Our results indicate qualitative and quantitative deficiencies in teaching ECG interpretation at medical schools. PMID:26541993

  8. Quality assessment of digital annotated ECG data from clinical trials by the FDA ECG Warehouse.

    Science.gov (United States)

    Sarapa, Nenad

    2007-09-01

    The FDA mandates that digital electrocardiograms (ECGs) from 'thorough' QTc trials be submitted into the ECG Warehouse in Health Level 7 extended markup language format with annotated onset and offset points of waveforms. The FDA did not disclose the exact Warehouse metrics and minimal acceptable quality standards. The author describes the Warehouse scoring algorithms and metrics used by FDA, points out ways to improve FDA review and suggests Warehouse benefits for pharmaceutical sponsors. The Warehouse ranks individual ECGs according to their score for each quality metric and produces histogram distributions with Warehouse-specific thresholds that identify ECGs of questionable quality. Automatic Warehouse algorithms assess the quality of QT annotation and duration of manual QT measurement by the central ECG laboratory.

  9. WAVELET ANALYSIS OF ABNORMAL ECGS

    Directory of Open Access Journals (Sweden)

    Vasudha Nannaparaju

    2014-02-01

    Full Text Available Detection of the warning signals by the heart can be diagnosed from ECG. An accurate and reliable diagnosis of ECG is very important however which is cumbersome and at times ambiguous in time domain due to the presence of noise. Study of ECG in wavelet domain using both continuous Wavelet transform (CWT and discrete Wavelet transform (DWT, with well known wavelet as well as a wavelet proposed by the authors for this investigation is found to be useful and yields fairly reliable results. In this study, Wavelet analysis of ECGs of Normal, Hypertensive, Diabetic and Cardiac are carried out. The salient feature of the study is that detection of P and T phases in wavelet domain is feasible which are otherwise feeble or absent in raw ECGs.

  10. Ecg manifestations in dengue infection

    International Nuclear Information System (INIS)

    Tarique, S.; Murtaza, G.; Asif, S.; Qureshi, I.H.

    2013-01-01

    To determine the frequency of ECG changes in patients with dengue fever and dengue hemorrhagic fever. Place of study: Department of Medicine, Mayo Hospital Lahore Duration of study: September to November 201 Study design: Cross sectional analytical study Patient and methods: 116 patients with dengue infection were enrolled in the study. Their clinical presentation and examination was duly noted. Each patient had baseline and then regular monitoring of blood counts, metabolic profile and fluid status. Patients with Dengue Hemorrhagic fever underwent radiological examination in form of chest radiograph and ultrasound abdomen. ECG was carried out in all patients. Results: Out of 116 patients, 61(52.6%) suffered from Dengue Fever and 55(47.4%) had Dengue Hemorrhagic Fever. Overall 78 patients had normal ECG. Abnormal ECG findings like tachycardia, bradycardia, supraventricular tachycardia, left bundle branch block, ST depression, poor progression of R wave were noted. There was no significant relationship of ECG findings with the disease. Conclusion: ECG changes can occur in dengue infection with or without cardiac symptoms. Commonly noted findings were ST depression and bradycardia. (author)

  11. Utility of the CORD ECG Database in Evaluating ECG Interpretation by Emergency Medicine Residents

    Directory of Open Access Journals (Sweden)

    Wong, Hubert E

    2002-10-01

    Full Text Available OBJECTIVES: Electrocardiograph (ECG interpretation is a vital component of Emergency Medicine (EM resident education, but few studies have formally examined ECG teaching methods used in residency training. Recently, the Council of EM Residency Directors (CORD developed an Internet database of 395 ECGs that have been extensively peer-reviewed to incorporate all findings and abnormalities. We examined the efficacy of this database in assessing EM residents' skills in ECG interpretation. METHODS: We used the CORD ECG database to evaluate residents at our academic three-year EM residency. Thirteen residents participated, including four first-year, four second-year, and five third-year residents. Twenty ECGs were selected using 14 search criteria representing a broad range of abnormalities, including infarction, rhythm, and conduction abnormalities. Exams were scored based on all abnormalities and findings listed in the teaching points accompanying each ECG. We assigned points to each abnormal finding based on clinical relevance. RESULTS: Out of a total of 183 points in our clinically weighted scoring system, first-year residents scored an average of 99 points (54.1% [9 1- 1191, second-year residents 11 1 points (60.4% [97-1261, and third-year residents 130 points (7 1.0% [94- 1501, p = 0.12. Clinically relevant abnormalities, including anterior and inferior myocardial infarctions, were most frequently diagnosed correctly, while posterior infarction was more frequently missed. Rhythm abnormalities including ventricular and supraventricular tachycardias were most frequently diagnosed correctly, while conduction abnormalities including left bundle branch block and atrioventricular (AV block were more frequently missed. CONCLUSION: The CORD database represents a valuable resource in the assessment and teaching of ECG skills, allowing more precise identification of areas upon which instruction should be further focused or individually tailored. Our

  12. Individual Biometric Identification Using Multi-Cycle Electrocardiographic Waveform Patterns

    Directory of Open Access Journals (Sweden)

    Wonki Lee

    2018-03-01

    Full Text Available The electrocardiogram (ECG waveform conveys information regarding the electrical property of the heart. The patterns vary depending on the individual heart characteristics. ECG features can be potentially used for biometric recognition. This study presents a new method using the entire ECG waveform pattern for matching and demonstrates that the approach can potentially be employed for individual biometric identification. Multi-cycle ECG signals were assessed using an ECG measuring circuit, and three electrodes can be patched on the wrists or fingers for considering various measurements. For biometric identification, our-fold cross validation was used in the experiments for assessing how the results of a statistical analysis will generalize to an independent data set. Four different pattern matching algorithms, i.e., cosine similarity, cross correlation, city block distance, and Euclidean distances, were tested to compare the individual identification performances with a single channel of ECG signal (3-wire ECG. To evaluate the pattern matching for biometric identification, the ECG recordings for each subject were partitioned into training and test set. The suggested method obtained a maximum performance of 89.9% accuracy with two heartbeats of ECG signals measured on the wrist and 93.3% accuracy with three heartbeats for 55 subjects. The performance rate with ECG signals measured on the fingers improved up to 99.3% with two heartbeats and 100% with three heartbeats of signals for 20 subjects.

  13. Individual Biometric Identification Using Multi-Cycle Electrocardiographic Waveform Patterns.

    Science.gov (United States)

    Lee, Wonki; Kim, Seulgee; Kim, Daeeun

    2018-03-28

    The electrocardiogram (ECG) waveform conveys information regarding the electrical property of the heart. The patterns vary depending on the individual heart characteristics. ECG features can be potentially used for biometric recognition. This study presents a new method using the entire ECG waveform pattern for matching and demonstrates that the approach can potentially be employed for individual biometric identification. Multi-cycle ECG signals were assessed using an ECG measuring circuit, and three electrodes can be patched on the wrists or fingers for considering various measurements. For biometric identification, our-fold cross validation was used in the experiments for assessing how the results of a statistical analysis will generalize to an independent data set. Four different pattern matching algorithms, i.e., cosine similarity, cross correlation, city block distance, and Euclidean distances, were tested to compare the individual identification performances with a single channel of ECG signal (3-wire ECG). To evaluate the pattern matching for biometric identification, the ECG recordings for each subject were partitioned into training and test set. The suggested method obtained a maximum performance of 89.9% accuracy with two heartbeats of ECG signals measured on the wrist and 93.3% accuracy with three heartbeats for 55 subjects. The performance rate with ECG signals measured on the fingers improved up to 99.3% with two heartbeats and 100% with three heartbeats of signals for 20 subjects.

  14. Evaluation of a novel portable capacitive ECG system in the clinical practice for a fast and simple ECG assessment in patients presenting with chest pain: FIDET (Fast Infarction Diagnosis ECG Trial)

    OpenAIRE

    Rasenack, Eva C. L.; Oehler, Martin; Els?sser, Albrecht; Schilling, Meinhard; Maier, Lars S.

    2012-01-01

    Background Electrocardiogram (ECG) assessment plays a crucial role in patients presenting with chest pain and suspected acute coronary syndrome (ACS). In a pilot study, we previously evaluated a capacitive ECG system (cECG) as a novel ECG technique for a fast and simple ECG assessment in patients with ST-elevation myocardial infarction (STEMI). In a next step, the sensitivity and specificity of this novel ECG technique have to be assessed in patients with ACS. Hypothesis The Fast Infarction D...

  15. Are ECG abnormalities in Noonan syndrome characteristic for the syndrome?

    NARCIS (Netherlands)

    Raaijmakers, R.; Noordam, C.; Noonan, J.A.; Croonen, E.A.; Burgt, C.J.A.M. van der; Draaisma, J.M.T.

    2008-01-01

    Of all patients with Noonan syndrome, 50-90% have one or more congenital heart defects. The most frequent occurring are pulmonary stenosis (PS) and hypertrophic cardiomyopathy. The electrocardiogram (ECG) of a patient with Noonan syndrome often shows a characteristic pattern, with a left axis

  16. Deep Learning for ECG Classification

    Science.gov (United States)

    Pyakillya, B.; Kazachenko, N.; Mikhailovsky, N.

    2017-10-01

    The importance of ECG classification is very high now due to many current medical applications where this problem can be stated. Currently, there are many machine learning (ML) solutions which can be used for analyzing and classifying ECG data. However, the main disadvantages of these ML results is use of heuristic hand-crafted or engineered features with shallow feature learning architectures. The problem relies in the possibility not to find most appropriate features which will give high classification accuracy in this ECG problem. One of the proposing solution is to use deep learning architectures where first layers of convolutional neurons behave as feature extractors and in the end some fully-connected (FCN) layers are used for making final decision about ECG classes. In this work the deep learning architecture with 1D convolutional layers and FCN layers for ECG classification is presented and some classification results are showed.

  17. An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment.

    Science.gov (United States)

    Rundo, Francesco; Conoci, Sabrina; Ortis, Alessandro; Battiato, Sebastiano

    2018-01-30

    Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG "combo" pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting "clean" PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach.

  18. Comparative study of measured heart cycle phase durations: standard lead ECG versus original ascending aorta lead ECG

    Directory of Open Access Journals (Sweden)

    Sergey V. Kolmakov

    2012-11-01

    Full Text Available Aims The present paper aims at evaluating the existing difference in duration measurements of the same heart cycle phases in the standard V3, V4, V5, V6 leads ECG versus original HDA lead ECG of the ascending aorta. Materials and methods The method of changing the filter pass band is used. Its essence is in artificial changing of the conditions of the signal recording carrying the informative indications of the initial information used in hemodynamic equations. The method also enables calculating the percentage deviation from the initial values. The principle of balance of the blood volume entering the heart and the blood volume leaving the heart is used to trace the minimal deviations and their respective recording conditions. Results In each of the V3, V4, V5, V6 ECG leads durations of the same phases have different values. The values measured on the ECG of the ascending aorta and those measured using the standard V4 ECG lead differ slightly. Conclusion For heart cycle phase analysis it is possible to use only the ECG of the ascending aorta and V4 standard lead ECG. Using conventional standard ECG leads causes an error up to 25%.

  19. Experimental evaluations of wearable ECG monitor.

    Science.gov (United States)

    Ha, Kiryong; Kim, Youngsung; Jung, Junyoung; Lee, Jeunwoo

    2008-01-01

    Healthcare industry is changing with ubiquitous computing environment and wearable ECG measurement is one of the most popular approaches in this healthcare industry. Reliability and performance of healthcare device is fundamental issue for widespread adoptions, and interdisciplinary perspectives of wearable ECG monitor make this more difficult. In this paper, we propose evaluation criteria considering characteristic of both ECG measurement and ubiquitous computing. With our wearable ECG monitors, various levels of experimental analysis are performed based on evaluation strategy.

  20. 3D Finite Element Electrical Model of Larval Zebrafish ECG Signals

    Science.gov (United States)

    Crowcombe, James; Dhillon, Sundeep Singh; Hurst, Rhiannon Mary; Egginton, Stuart; Müller, Ferenc; Sík, Attila; Tarte, Edward

    2016-01-01

    Assessment of heart function in zebrafish larvae using electrocardiography (ECG) is a potentially useful tool in developing cardiac treatments and the assessment of drug therapies. In order to better understand how a measured ECG waveform is related to the structure of the heart, its position within the larva and the position of the electrodes, a 3D model of a 3 days post fertilisation (dpf) larval zebrafish was developed to simulate cardiac electrical activity and investigate the voltage distribution throughout the body. The geometry consisted of two main components; the zebrafish body was modelled as a homogeneous volume, while the heart was split into five distinct regions (sinoatrial region, atrial wall, atrioventricular band, ventricular wall and heart chambers). Similarly, the electrical model consisted of two parts with the body described by Laplace’s equation and the heart using a bidomain ionic model based upon the Fitzhugh-Nagumo equations. Each region of the heart was differentiated by action potential (AP) parameters and activation wave conduction velocities, which were fitted and scaled based on previously published experimental results. ECG measurements in vivo at different electrode recording positions were then compared to the model results. The model was able to simulate action potentials, wave propagation and all the major features (P wave, R wave, T wave) of the ECG, as well as polarity of the peaks observed at each position. This model was based upon our current understanding of the structure of the normal zebrafish larval heart. Further development would enable us to incorporate features associated with the diseased heart and hence assist in the interpretation of larval zebrafish ECGs in these conditions. PMID:27824910

  1. 'Brugada ECG' elicited by imipramine overdose

    NARCIS (Netherlands)

    van den Berg, M. P.; Tulleken, J. E.; Wilde, A. A. M.

    2004-01-01

    The ECG hallmark of the Brugada syndrome is ST-segment elevation in the right precordial leads. However, a 'Brugada ECG' may also occasionally be caused by other conditions. We report a case of a Brugada ECG due to an overdose of imipramine, a tricyclic antidepressant. The patient, a 66-year-old

  2. e-SCP-ECG+ Protocol: An Expansion on SCP-ECG Protocol for Health Telemonitoring—Pilot Implementation

    Directory of Open Access Journals (Sweden)

    George J. Mandellos

    2010-01-01

    Full Text Available Standard Communication Protocol for Computer-assisted Electrocardiography (SCP-ECG provides standardized communication among different ECG devices and medical information systems. This paper extends the use of this protocol in order to be included in health monitoring systems. It introduces new sections into SCP-ECG structure for transferring data for positioning, allergies, and five additional biosignals: noninvasive blood pressure (NiBP, body temperature (Temp, Carbon dioxide (CO2, blood oxygen saturation (SPO2, and pulse rate. It also introduces new tags in existing sections for transferring comprehensive demographic data. The proposed enhanced version is referred to as e-SCP-ECG+ protocol. This paper also considers the pilot implementation of the new protocol as a software component in a Health Telemonitoring System.

  3. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    International Nuclear Information System (INIS)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T.

    2004-01-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P [de

  4. [Analysis of pacemaker ECGs].

    Science.gov (United States)

    Israel, Carsten W; Ekosso-Ejangue, Lucy; Sheta, Mohamed-Karim

    2015-09-01

    The key to a successful analysis of a pacemaker electrocardiogram (ECG) is the application of the systematic approach used for any other ECG without a pacemaker: analysis of (1) basic rhythm and rate, (2) QRS axis, (3) PQ, QRS and QT intervals, (4) morphology of P waves, QRS, ST segments and T(U) waves and (5) the presence of arrhythmias. If only the most obvious abnormality of a pacemaker ECG is considered, wrong conclusions can easily be drawn. If a systematic approach is skipped it may be overlooked that e.g. atrial pacing is ineffective, the left ventricle is paced instead of the right ventricle, pacing competes with intrinsic conduction or that the atrioventricular (AV) conduction time is programmed too long. Apart from this analysis, a pacemaker ECG which is not clear should be checked for the presence of arrhythmias (e.g. atrial fibrillation, atrial flutter, junctional escape rhythm and endless loop tachycardia), pacemaker malfunction (e.g. atrial or ventricular undersensing or oversensing, atrial or ventricular loss of capture) and activity of specific pacing algorithms, such as automatic mode switching, rate adaptation, AV delay modifying algorithms, reaction to premature ventricular contractions (PVC), safety window pacing, hysteresis and noise mode. A systematic analysis of the pacemaker ECG almost always allows a probable diagnosis of arrhythmias and malfunctions to be made, which can be confirmed by pacemaker control and can often be corrected at the touch of the right button to the patient's benefit.

  5. Distinct patterns of epigenetic marks and transcription factor binding ...

    Indian Academy of Sciences (India)

    Distinct patterns of epigenetic marks and transcription factor binding sites across promoters of sense-intronic long noncoding RNAs. Sourav Ghosh, Satish Sati, Shantanu Sengupta and Vinod Scaria. J. Genet. 94, 17–25. Gencode V9 lncRNA gene : 11004. Known lncRNA : 1175. Novel lncRNA : 5898. Putative lncRNA :.

  6. Multi detector computed tomography (MDCT) of the aortic root; ECG-gated verses non-ECG-gated examinations

    International Nuclear Information System (INIS)

    Kristiansen, Joanna; Guenther, Anne; Aalokken, Trond Mogens; Andersen, Rune

    2011-01-01

    Purpose: Motion artifacts may degrade a conventional CT examination of the ascending aorta and hinder accurate diagnosis. We quantitatively compared retrospectively electrocardiographic (ECG) -gated multi detector computed tomography (MDCT) with non-ECG-gated MDCT in order to demonstrate whether or not one of the methods should be preferred. Method: The study included seventeen patients with surgically reconstructed aortic root and reimplanted coronary arteries. All patients had undergone both non-gated MDCT and retrospectively ECG-gated MDCT employing a stringently modulated tube current with single phase image reconstruction. The incidence of motion artifacts in the left main coronary artery (LM), proximal right coronary artery (RCA), and aortic root and ascending aorta were rated using a four point scale. The effective dose for each scan was calculated and normalized to a 15 cm scan length. Statistical analysis of motion artifacts and radiation dose was performed using Wilcoxon matched pairs signed rank sum test. Results: A significant reduction in motion artifacts was found in all three vessels in images from the retrospectively ECG-gated scans (LM: P = 0.005, RCA: P = 0.015, aorta: P = 0.003). The mean normalized effective radiation dose was 3.69 mSv (±1.03) for the non-ECG-gated scans and 16.37 mSv (±2.53) for the ECG-gated scans. Conclusion: Retrospective ECG-gating with single phase reconstruction significantly reduces the incidence of motion artifacts in the aortic root and the proximal portion of the coronary arteries but at the expense of a fourfold increase in radiation dose.

  7. ECG acquisition and automated remote processing

    CERN Document Server

    Gupta, Rajarshi; Bera, Jitendranath

    2014-01-01

    The book is focused on the area of remote processing of ECG in the context of telecardiology, an emerging area in the field of Biomedical Engineering Application. Considering the poor infrastructure and inadequate numbers of physicians in rural healthcare clinics in India and other developing nations, telemedicine services assume special importance. Telecardiology, a specialized area of telemedicine, is taken up in this book considering the importance of cardiac diseases, which is prevalent in the population under discussion. The main focus of this book is to discuss different aspects of ECG acquisition, its remote transmission and computerized ECG signal analysis for feature extraction. It also discusses ECG compression and application of standalone embedded systems, to develop a cost effective solution of a telecardiology system.

  8. Heartbeat Classification Using Abstract Features From the Abductive Interpretation of the ECG.

    Science.gov (United States)

    Teijeiro, Tomas; Felix, Paulo; Presedo, Jesus; Castro, Daniel

    2018-03-01

    This paper aims to prove that automatic beat classification on ECG signals can be effectively solved with a pure knowledge-based approach, using an appropriate set of abstract features obtained from the interpretation of the physiological processes underlying the signal. A set of qualitative morphological and rhythm features are obtained for each heartbeat as a result of the abductive interpretation of the ECG. Then, a QRS clustering algorithm is applied in order to reduce the effect of possible errors in the interpretation. Finally, a rule-based classifier assigns a tag to each cluster. The method has been tested with the MIT-BIH Arrhythmia Database records, showing a significantly better performance than any other automatic approach in the state-of-the-art, and even improving most of the assisted approaches that require the intervention of an expert in the process. The most relevant issues in ECG classification, related to a large extent to the variability of the signal patterns between different subjects and even in the same subject over time, will be overcome by changing the reasoning paradigm. This paper demonstrates the power of an abductive framework for time-series interpretation to make a qualitative leap in the significance of the information extracted from the ECG by automatic methods.

  9. Correlation of resting ECG, stress ECG and thallium scan in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Amin, W.; Khan, M.Z.A.; Ahmed, A.; Kiani, M.R.

    1987-01-01

    This study includes 70 cases who underwent myocardial perfusion studies with thallium 201 during the year 1984-85. They were studied clinically, had their resting ECGs, stress ECGs and coronary angiograms. Majority of these patients were males, their ages ranged between 34-70 years. The patients population included with typical/atypical chest pain, some with resting ECG abnormalities, after coronary angiography and a few after coronary artery bypass graft surgery. The result of all the modalities were compared with the conventional gold standard for ischaemic heart disease, i.e. coronary angiogram. It is concluded that the sensitivity of resting ECG in the diagnosis of ischaemic heart disease is very low. The exercise test alone was found conclusive in about 74% of patients while sensitivity of thallium scan was 66% in this particular group of patients. (author)

  10. Ecg changes after dipyridamole infusion in patients undergoing myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Taherpour, M.; Zakavi, R.; Ariana, K.

    2002-01-01

    Dipyridamole is used as the main pharmacological stress agent in patient referred for myocardial perfusion imaging. This vasodilator agent makes difference between normal and abnormal coronary perfusion. Some authors believe that post-Dipyridamole Ecg changes have low sensitivity and relatively high specificity for ischemic detection. This study tries to evaluate this issue. All patients who referred to nuclear medicine department for Myocardial Perfusion Imaging and were not suitable for treadmill E T T, and had no L BBB pattern in basal Ecg were included in the study. Basal and post Dipyridamole Ecg were interpreted with a cardiologist after infusion of 142 u g/kg/min of Dipyridamole and all changes as well as basal Ecg abnormalities were recorded. Also Q Tc were calculated in all Ecg records: M P Is were interpreted by a nuclear medicine specialist and summed stress and rest scores were determined. Two hundred patients including 89 female (44.5%) and 111 male (55.5%) with a mean age of 55.2 years and age range of 30-85 years were studied. Mean basal and post Dipyridamole heart rates were 72.2/min and 84.8/min and mean basal and post Dipyridamole Qt Cs were 419.6 msec and 435.7 msec respectively. New Ecg changes were noted in 22.5% of cases and consisted of 1% T-wave flattening, 1% T-wave inversion, 16.5% St depression and 4% Pseudo normalization. Horizontal pattern was the main type of St segment depression (83.%) among new S T changes. Mean St depression severity was 0.8 mm with a range of 0.5-2 mm. New St depression was noted in lateral leads (Excluding high lateral) in 62.5% of new S T changes. M P I was interpreted normal in 4% of cases and showed some degrees of ischemia in 42% of the cases. The mean post Dipyridamole heart rate increment, was 11.2/ min patients with abnormal scintigraphy (infarct and/or ischemia) compared to 14.5/ min in normal cases. (P=0.009). Also Qt c increment in patients with ischemia was significantly more than patients with simple

  11. Variable threshold method for ECG R-peak detection.

    Science.gov (United States)

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  12. ECG-gating in non-cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Cairo, F.

    1987-01-01

    This paper reports the results of the ECG-gating in non-cardiac digital subtraction angiography (DSA). One hundred and fifteen patients underwent DSA (126 examinations); ECG-gating was applied in 66/126 examinations: images recorded at 70% of R wave were subtracted. Artifacts produced by vascular movements were evaluated in all patients: only 40 examinations, carried out whithout ECG-gating, showed vascular artifacts. The major advantage of the ECG-gated DSA is the more efficent subtraction because of the better images superimposition: therefore, ECG-gating can be clinically helpful. On the contrary, it could be a problem in arrhytmic or bradycardic patients. ECG-gating is helpful in DSA imaging of the thoracic and abdominal aorta and of the cervical and renal arteries. In the examinations of peripheral vessels of the limbs it is not so efficent as in the trunk or in the neck

  13. Reliability of Computer Analysis of Electrocardiograms (ECG) of ...

    African Journals Online (AJOL)

    Background: Computer programmes have been introduced to electrocardiography (ECG) with most physicians in Africa depending on computer interpretation of ECG. This study was undertaken to evaluate the reliability of computer interpretation of the 12-Lead ECG in the Black race. Methodology: Using the SCHILLER ...

  14. Changes in blood pressure, bmi and ecg patterns in women using low-dose contraceptives

    International Nuclear Information System (INIS)

    Syed, S.; Rahim, M.; Javed, M.; Qureshi, M.A.

    2008-01-01

    To determine the cardiovascular risk factors in users of second generation contraceptives by recording changes in body mass index, blood pressure and electrocardiogram. Sixty four women volunteered for this study (age range 20-35 years), belonging to low-income group with similar socio-cultural background. The Body Mass Index (BMI) was calculated by measuring height and weight of the subjects, systolic and diastolic blood pressure and ECG recording by standard method. The group means, standard deviations and coefficient correlation for interrelationship among variables in respective groups of subjects were calculated using relevant statistical method and software program. There was no significant difference between BMI of two types of contraceptive users as compared to non users, but BMI was significantly correlated with both systolic and diastolic blood pressures in injectable users as compared to controls. ECG alterations frequently observed in contraceptive users (40%) as compared to controls were normal findings. It was observed that women aged < 30 years and using contraceptives for more than three years had a tendency to gain weight and developed a mild increase in systolic and diastolic blood pressures. (author)

  15. Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cunguang Lou

    2016-11-01

    Full Text Available This paper describes the development of a graphene-based dry flexible electrocardiography (ECG electrode and a portable wireless ECG measurement system. First, graphene films on polyethylene terephthalate (PET substrates and graphene paper were used to construct the ECG electrode. Then, a graphene textile was synthesized for the fabrication of a wearable ECG monitoring system. The structure and the electrical properties of the graphene electrodes were evaluated using Raman spectroscopy, scanning electron microscopy (SEM, and alternating current impedance spectroscopy. ECG signals were then collected from healthy subjects using the developed graphene electrode and portable measurement system. The results show that the graphene electrode was able to acquire the typical characteristics and features of human ECG signals with a high signal-to-noise (SNR ratio in different states of motion. A week-long continuous wearability test showed no degradation in the ECG signal quality over time. The graphene-based flexible electrode demonstrates comfortability, good biocompatibility, and high electrophysiological detection sensitivity. The graphene electrode also combines the potential for use in long-term wearable dynamic cardiac activity monitoring systems with convenience and comfort for use in home health care of elderly and high-risk adults.

  16. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used to...

  17. Expert knowledge for computerized ECG interpretation

    NARCIS (Netherlands)

    J.A. Kors (Jan)

    1992-01-01

    textabstractIn this study, two main questions are addressed: (1) Can the time consuming and cumbersome development and refinement of (heuristic) ECG classifiers be alleviated, and (2) Is it possible to increase diagnostic performance of ECG computer programs by combining knowledge from multiple

  18. Atrial flutter: from ECG to electroanatomical 3D mapping

    Directory of Open Access Journals (Sweden)

    Livio Dei Cas

    2009-08-01

    Full Text Available Atrial flutter is a common arrhythmia that may cause significant symptoms, including palpitations, dyspnea, chest pain and even syncope. Frequently it’s possible to diagnose atrial flutter with a 12-lead surface ECG, looking for distinctive waves in leads II, III, aVF, aVL, V1,V2. Puech and Waldo developed the first classification of atrial flutter in the 1970s. These authors divided the arrhythmia into type I and type II. Therefore, in 2001 the European Society of Cardiology and the North American Society of Pacing and Electrophysiology developed a new classification of atrial flutter, based not only on the ECG, but also on the electrophysiological mechanism. New developments in endocardial mapping, including the electroanatomical 3D mapping system, have greatly expanded our understanding of the mechanism of arrhythmias. More recently, Scheinman et al, provided an updated classification and nomenclature. The terms like common, uncommon, typical, reverse typical or atypical flutter are abandoned because they may generate confusion. The authors worked out a new terminology, which differentiates atrial flutter only on the basis of electrophysiological mechanism. (Heart International 2006; 3-4: 161-70

  19. ECG authentication in post-exercise situation.

    Science.gov (United States)

    Dongsuk Sung; Jeehoon Kim; Myungjun Koh; Kwangsuk Park

    2017-07-01

    Human authentication based on electrocardiogram (ECG) has been a remarkable issue for recent ten years. This paper proposed an authentication technology with the ECG data recorded after the harsh exercise. 55 subjects voluntarily attended to this experiment. A stepper was used as an exercise equipment. The subjects are asked to do stepper for 5 minutes and their ECG signals are acquired before and after the exercise in rest, sitting posture. Linear discriminant analysis (LDA) was used for both feature extraction and classification. Even though, within the first 1 minute recording, the subject recognition accuracy was 59.64%, which is too low to utilize, after one minute the accuracy was higher than 90% and it increased up to 96.22% within 5 minutes, which is plausible to use in authentication circumstances. Therefore, we have concluded that ECG authentication techniques will be able to be used after 1 minute of catching breath.

  20. Sparse Matrix for ECG Identification with Two-Lead Features

    Directory of Open Access Journals (Sweden)

    Kuo-Kun Tseng

    2015-01-01

    Full Text Available Electrocardiograph (ECG human identification has the potential to improve biometric security. However, improvements in ECG identification and feature extraction are required. Previous work has focused on single lead ECG signals. Our work proposes a new algorithm for human identification by mapping two-lead ECG signals onto a two-dimensional matrix then employing a sparse matrix method to process the matrix. And that is the first application of sparse matrix techniques for ECG identification. Moreover, the results of our experiments demonstrate the benefits of our approach over existing methods.

  1. A capacitive ECG array with visual patient feedback.

    Science.gov (United States)

    Eilebrecht, Benjamin; Schommartz, Antje; Walter, Marian; Wartzek, Tobias; Czaplik, Michael; Leonhardt, Steffen

    2010-01-01

    Capacitive electrocardiogram (ECG) sensing is a promising technique for less constraining vital signal measurement and close to a commercial application. Even bigger trials testing the diagnostic significance were already done with single lead systems. Anyway, most applications to be found in research are limited to one channel and thus limited in its diagnostic relevance as only diseases coming along with a change of the heart rate can be diagnosed adequately. As a consequence the need for capacitive multi-channel ECGs combining the diagnostic relevance and the advantages of capacitive ECG sensing emerges. This paper introduces a capacitive ECG measurement system which allows the recording of standardized ECG leads according to Einthoven and Goldberger by means of an electrode array with nine electrodes.

  2. A cloud computing based 12-lead ECG telemedicine service.

    Science.gov (United States)

    Hsieh, Jui-Chien; Hsu, Meng-Wei

    2012-07-28

    Due to the great variability of 12-lead ECG instruments and medical specialists' interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists' decision making support in emergency telecardiology. We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan.

  3. Research on comparison of exposure with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode in coronary multi-slice spiral CT angiography

    International Nuclear Information System (INIS)

    Liu Bin; Guo Senlin; Wei Lan; Fei Xiaolu; Bai Mei

    2009-01-01

    Objective: The objective of this article was to compare patients dose with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode during coronary MSCT angiography. Methods: The research was based on phantom experiment and computer simulation to get the mean value of peak skin dose data and effective dose data respectively and to analyze deterministic and stochastic radiation risk. Results: The peak skin dose using ECG mode alone and using ECG and CAREDose 4D mode with the same image noise level was (87.4 ± 0.9) and (45.9 ± 1.2) mGy respectively. Effective dose was 17 and 10 rosy for ECG mode and ECG and CAREDose 4D mode respectively. Comparing with ECG mode alone, ECG and CAREDose 4D mode reduced organ dose of gonad, red marrow, lung, stomach, breast and thyroid by 40.0%, 36.7%, 39.3%, 37.7%, 38.8% and 38.9%, respectively. Conclusion: Results showed that ECG and CAREDose 4D mode can reduce radiation dose effectively comparing using ECG mode alone, and that ECG and CAREDose 4D mode should be widely applied clinically with appropriate initial settings. (authors)

  4. Wearable Textile Electrodes for ECG Measurement

    Directory of Open Access Journals (Sweden)

    Lukas Vojtech

    2013-01-01

    Full Text Available The electrocardiogram (ECG is one of the most important parameters for monitoring of the physiological state of a person. Currently available systems for ECG monitoring are both stationary and wearable, but the comfort of the monitored person is not at a satisfactory level because these systems are not part of standard clothing. This article is therefore devoted to the development and measurement of wearable textile electrodes for ECG measurement device with high comfort for the user. The electrode material is made of electrically conductive textile. This creates a textile composite that guarantees high comfort for the user while ensuring good quality of ECG measurements. The composite is implemented by a carrier (a T-shirt with flame retardant and sensing electrodes embroidered with yarn based on a mixture of polyester coated with silver nanoparticles and cotton. The electrodes not only provide great comfort but are also antibacterial and antiallergic due to silver nanoparticles.

  5. A Novel 12-Lead ECG T-Shirt with Active Electrodes

    Directory of Open Access Journals (Sweden)

    Anna Boehm

    2016-11-01

    Full Text Available We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403. The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.

  6. Automatic ECG quality scoring methodology: mimicking human annotators

    International Nuclear Information System (INIS)

    Johannesen, Lars; Galeotti, Loriano

    2012-01-01

    An algorithm to determine the quality of electrocardiograms (ECGs) can enable inexperienced nurses and paramedics to record ECGs of sufficient diagnostic quality. Previously, we proposed an algorithm for determining if ECG recordings are of acceptable quality, which was entered in the PhysioNet Challenge 2011. In the present work, we propose an improved two-step algorithm, which first rejects ECGs with macroscopic errors (signal absent, large voltage shifts or saturation) and subsequently quantifies the noise (baseline, powerline or muscular noise) on a continuous scale. The performance of the improved algorithm was evaluated using the PhysioNet Challenge database (1500 ECGs rated by humans for signal quality). We achieved a classification accuracy of 92.3% on the training set and 90.0% on the test set. The improved algorithm is capable of detecting ECGs with macroscopic errors and giving the user a score of the overall quality. This allows the user to assess the degree of noise and decide if it is acceptable depending on the purpose of the recording. (paper)

  7. Basic principles of the ECG. The normal ECG

    African Journals Online (AJOL)

    Angel_D

    Southern Sudan Medical Journal vol 3. no 2. 26. How to read an ... Reduce some of the anxiety juniors often experience when faced with an ECG. ... This overall direction of travel of the electrical .... Anne Lancey, Education Centre, St Mary's Hospital, Isle of Wight, UK. .... 'method' section explains how the literature search.

  8. Freeware eLearning Flash-ECG for learning electrocardiography.

    Science.gov (United States)

    Romanov, Kalle; Kuusi, Timo

    2009-06-01

    Electrocardiographic (ECG) analysis can be taught in eLearning programmes with suitable software that permits the effective use of basic tools such as a ruler and a magnifier, required for measurements. The Flash-ECG (Research & Development Unit for Medical Education, University of Helsinki, Finland) was developed to enable teachers and students to use scanned and archived ECGs on computer screens and classroom projectors. The software requires only a standard web browser with a Flash plug-in and can be integrated with learning environments (Blackboard/WebCT, Moodle). The Flash-ECG is freeware and is available to medical teachers worldwide.

  9. A cloud computing based 12-lead ECG telemedicine service

    Science.gov (United States)

    2012-01-01

    Background Due to the great variability of 12-lead ECG instruments and medical specialists’ interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists’ decision making support in emergency telecardiology. Methods We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG) service to realize ubiquitous 12-lead ECG tele-diagnosis. Results This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. Conclusions This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan. PMID:22838382

  10. A cloud computing based 12-lead ECG telemedicine service

    Directory of Open Access Journals (Sweden)

    Hsieh Jui-chien

    2012-07-01

    Full Text Available Abstract Background Due to the great variability of 12-lead ECG instruments and medical specialists’ interpretation skills, it remains a challenge to deliver rapid and accurate 12-lead ECG reports with senior cardiologists’ decision making support in emergency telecardiology. Methods We create a new cloud and pervasive computing based 12-lead Electrocardiography (ECG service to realize ubiquitous 12-lead ECG tele-diagnosis. Results This developed service enables ECG to be transmitted and interpreted via mobile phones. That is, tele-consultation can take place while the patient is on the ambulance, between the onsite clinicians and the off-site senior cardiologists, or among hospitals. Most importantly, this developed service is convenient, efficient, and inexpensive. Conclusions This cloud computing based ECG tele-consultation service expands the traditional 12-lead ECG applications onto the collaboration of clinicians at different locations or among hospitals. In short, this service can greatly improve medical service quality and efficiency, especially for patients in rural areas. This service has been evaluated and proved to be useful by cardiologists in Taiwan.

  11. Ischemic ECG abnormalities are associated with an increased risk for death among subjects with COPD, also among those without known heart disease.

    Science.gov (United States)

    Nilsson, Ulf; Blomberg, Anders; Johansson, Bengt; Backman, Helena; Eriksson, Berne; Lindberg, Anne

    2017-01-01

    An abstract, including parts of the results, has been presented at an oral session at the European Respiratory Society International Conference, London, UK, September 2016. Cardiovascular comorbidity contributes to increased mortality among subjects with COPD. However, the prognostic value of ECG abnormalities in COPD has rarely been studied in population-based surveys. To assess the impact of ischemic ECG abnormalities (I-ECG) on mortality among individuals with COPD, compared to subjects with normal lung function (NLF), in a population-based study. During 2002-2004, all subjects with FEV 1 /VC ECG in COPD (n=635) and referents [n=991, whereof 786 had NLF]. All ECGs were Minnesota-coded. Mortality data were collected until December 31, 2010. I-ECG was equally common in COPD and NLF. The 5-year cumulative mortality was higher among subjects with I-ECG in both groups (29.6% vs 10.6%, P ECG had increased risk for death assessed as the mortality risk ratio [95% confidence interval (CI)] when compared with NLF without I-ECG, 2.36 (1.45-3.85) and 1.65 (0.94-2.90) when adjusted for common confounders. When analyzed separately among the COPD cohort, the increased risk for death associated with I-ECG persisted after adjustment for FEV 1 % predicted, 1.89 (1.20-2.99). A majority of those with I-ECG had no previously reported heart disease (74.2% in NLF and 67.3% in COPD) and the pattern was similar among them. I-ECG was associated with an increased risk for death in COPD, independent of common confounders and disease severity. I-ECG was of prognostic value also among those without previously known heart disease.

  12. ECG telemetry in conscious guinea pigs.

    Science.gov (United States)

    Ruppert, Sabine; Vormberge, Thomas; Igl, Bernd-Wolfgang; Hoffmann, Michael

    2016-01-01

    During preclinical drug development, monitoring of the electrocardiogram (ECG) is an important part of cardiac safety assessment. To detect potential pro-arrhythmic liabilities of a drug candidate and for internal decision-making during early stage drug development an in vivo model in small animals with translatability to human cardiac function is required. Over the last years, modifications/improvements regarding animal housing, ECG electrode placement, and data evaluation have been introduced into an established model for ECG recordings using telemetry in conscious, freely moving guinea pigs. Pharmacological validation using selected reference compounds affecting different mechanisms relevant for cardiac electrophysiology (quinidine, flecainide, atenolol, dl-sotalol, dofetilide, nifedipine, moxifloxacin) was conducted and findings were compared with results obtained in telemetered Beagle dogs. Under standardized conditions, reliable ECG data with low variability allowing largely automated evaluation were obtained from the telemetered guinea pig model. The model is sensitive to compounds blocking cardiac sodium channels, hERG K(+) channels and calcium channels, and appears to be even more sensitive to β-blockers as observed in dogs at rest. QT interval correction according to Bazett and Sarma appears to be appropriate methods in conscious guinea pigs. Overall, the telemetered guinea pig is a suitable model for the conduct of early stage preclinical ECG assessment. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Empirical mode decomposition of the ECG signal for noise removal

    Science.gov (United States)

    Khan, Jesmin; Bhuiyan, Sharif; Murphy, Gregory; Alam, Mohammad

    2011-04-01

    Electrocardiography is a diagnostic procedure for the detection and diagnosis of heart abnormalities. The electrocardiogram (ECG) signal contains important information that is utilized by physicians for the diagnosis and analysis of heart diseases. So good quality ECG signal plays a vital role for the interpretation and identification of pathological, anatomical and physiological aspects of the whole cardiac muscle. However, the ECG signals are corrupted by noise which severely limit the utility of the recorded ECG signal for medical evaluation. The most common noise presents in the ECG signal is the high frequency noise caused by the forces acting on the electrodes. In this paper, we propose a new ECG denoising method based on the empirical mode decomposition (EMD). The proposed method is able to enhance the ECG signal upon removing the noise with minimum signal distortion. Simulation is done on the MIT-BIH database to verify the efficacy of the proposed algorithm. Experiments show that the presented method offers very good results to remove noise from the ECG signal.

  14. Biometric and Emotion Identification: An ECG Compression Based Method.

    Science.gov (United States)

    Brás, Susana; Ferreira, Jacqueline H T; Soares, Sandra C; Pinho, Armando J

    2018-01-01

    We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG). The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1) conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2) conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3) identification of the ECG record class, using a 1-NN (nearest neighbor) classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model.

  15. Hyperkalemia on ECG

    Directory of Open Access Journals (Sweden)

    Bryson Hicks

    2016-09-01

    Full Text Available History of present illness: A 34-year-old diabetic female presented to the emergency department with chest pain status-post AICD firing. She described the pain as a “12 out of 10” which woke her from sleep at 0200, one hour prior to arrival. Vitals were unremarkable. She had no known history of renal failure. Due to frequent ED visits for chronic pain, patient had difficult vascular access and nursing was initially unable to obtain IV access. An abnormal rhythm was noted on the cardiac monitor, and ECG was ordered. Significant findings: Initial ECG shows tall, peaked T waves, most prominently in V3 and V4, as well as QRS widening. These findings are consistent with hyperkalemia, which was promptly treated. Follow-up ECG post-treatment shows narrowing of the QRS complexes and normalization of peaked T waves. Discussion: The etiology of hyperkalemia may be due to an acute insult such as crush injury, drug side effect, or in acute renal failure, but may also occur in the setting of a chronic insult such as chronic kidney disease.1 As potassium rises, several abnormalities can be identified on ECG. Initially the T waves become peaked and the QRS complexes widen.2,3 This can devolve into a wide complex rhythm, ventricular tachycardia, ventricular fibrillation, or asystole. Patients may also experience systemic symptoms such as weakness or paralysis.1 In this particular case, labs showed a potassium of 7.6-mmol/L after initial treatment (see repeat EKG. While the incidence of hyperkalemia in the general population is not defined, the incidence in hospitalized patients is 1.3-10%.4-8 Impaired kidney function is the most common risk factor found in 33-83% of affected patients.4,5,8,9 Treatment for hyperkalemia generally includes IV insulin and IV dextrose and nebulized albuterol for intracellular shift of potassium, IV furosemide and IV fluids for dilution and renal excretion of furosemide, and IV calcium for stabilization of cardiac membranes.2,3

  16. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    Science.gov (United States)

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  17. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  18. ECG abnormalities in patients with chronic kidney disease

    International Nuclear Information System (INIS)

    Shafi, S.; Saleem, M.; Anjum, R.; Abdullah, W.; Shafi, T.

    2017-01-01

    Chronic kidney disease (CKD) is associated with increased risk of cardiovascular disease. Electrocardiographic (ECG) abnormalities are common in CKD patients. However, there is variation in literature regarding frequency of ECG abnormalities in CKD patients and limited information in local population. Methods: The study design was cross-sectional in nature. All patients between ages of 20-80 years with CKD not previously on renal replacement therapy who were admitted to nephrology ward at a tertiary care facility over a 6-month period were included. All patients underwent 12 lead electrocardiograms (ECG). ECG abnormalities were defined based on accepted standard criteria. Results: Total number of patients included in the study was 124. Mean age of all patients was 49.9+-13.8 years, 106 (84.8%) had hypertension, 84 (70%) had diabetes mellitus, and 35 (29.9%) had known cardiovascular disease. Mean serum creatinine was 7.2+-3.4 mg/dl, mean eGFR was 10.6+-9.2 ml/min/1.73 m/sup 2/. Overall 78.4% of all CKD patients have one or more ECG abnormality. Left ventricular hypertrophy (40%), Q waves (27.2%), ST segment elevation or depression (23.4%), prolonged QRS duration (19.2%), tachycardia (17.6%) and left and right atrial enlargement (17.6%) were the most common abnormalities. Conclusion: ECG abnormalities are common in hospitalized CKD patients in local population. All hospitalized CKD patients should undergo ECG to screen for cardiovascular disease. (author)

  19. The PLR-DTW method for ECG based biometric identification.

    Science.gov (United States)

    Shen, Jun; Bao, Shu-Di; Yang, Li-Cai; Li, Ye

    2011-01-01

    There has been a surge of research on electrocardiogram (ECG) signal based biometric for person identification. Though most of the existing studies claimed that ECG signal is unique to an individual and can be a viable biometric, one of the main difficulties for real-world applications of ECG biometric is the accuracy performance. To address this problem, this study proposes a PLR-DTW method for ECG biometric, where the Piecewise Linear Representation (PLR) is used to keep important information of an ECG signal segment while reduce the data dimension at the same time if necessary, and the Dynamic Time Warping (DTW) is used for similarity measures between two signal segments. The performance evaluation was carried out on three ECG databases, and the existing method using wavelet coefficients, which was proved to have good accuracy performance, was selected for comparison. The analysis results show that the PLR-DTW method achieves an accuracy rate of 100% for identification, while the one using wavelet coefficients achieved only around 93%.

  20. A novel biometric authentication approach using ECG and EMG signals.

    Science.gov (United States)

    Belgacem, Noureddine; Fournier, Régis; Nait-Ali, Amine; Bereksi-Reguig, Fethi

    2015-05-01

    Security biometrics is a secure alternative to traditional methods of identity verification of individuals, such as authentication systems based on user name and password. Recently, it has been found that the electrocardiogram (ECG) signal formed by five successive waves (P, Q, R, S and T) is unique to each individual. In fact, better than any other biometrics' measures, it delivers proof of subject's being alive as extra information which other biometrics cannot deliver. The main purpose of this work is to present a low-cost method for online acquisition and processing of ECG signals for person authentication and to study the possibility of providing additional information and retrieve personal data from an electrocardiogram signal to yield a reliable decision. This study explores the effectiveness of a novel biometric system resulting from the fusion of information and knowledge provided by ECG and EMG (Electromyogram) physiological recordings. It is shown that biometrics based on these ECG/EMG signals offers a novel way to robustly authenticate subjects. Five ECG databases (MIT-BIH, ST-T, NSR, PTB and ECG-ID) and several ECG signals collected in-house from volunteers were exploited. A palm-based ECG biometric system was developed where the signals are collected from the palm of the subject through a minimally intrusive one-lead ECG set-up. A total of 3750 ECG beats were used in this work. Feature extraction was performed on ECG signals using Fourier descriptors (spectral coefficients). Optimum-Path Forest classifier was used to calculate the degree of similarity between individuals. The obtained results from the proposed approach look promising for individuals' authentication.

  1. A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for Male.

    Science.gov (United States)

    Cho, Hakyung; Lee, Joo Hyeon

    2015-09-01

    Smart clothing is a sort of wearable device used for ubiquitous health monitoring. It provides comfort and efficiency in vital sign measurements and has been studied and developed in various types of monitoring platforms such as T-shirt and sports bra. However, despite these previous approaches, smart clothing for electrocardiography (ECG) monitoring has encountered a serious shortcoming relevant to motion artifacts caused by wearer movement. In effect, motion artifacts are one of the major problems in practical implementation of most wearable health-monitoring devices. In the ECG measurements collected by a garment, motion artifacts are usually caused by improper location of the electrode, leading to lack of contact between the electrode and skin with body motion. The aim of this study was to suggest a design for ECG-monitoring clothing contributing to reduction of motion artifacts. Based on the clothing science theory, it was assumed in this study that the stability of the electrode in a dynamic state differed depending on the electrode location in an ECG-monitoring garment. Founded on this assumption, effects of 56 electrode positions were determined by sectioning the surface of the garment into grids with 6 cm intervals in the front and back of the bodice. In order to determine the optimal locations of the ECG electrodes from the 56 positions, ECG measurements were collected from 10 participants at every electrode position in the garment while the wearer was in motion. The electrode locations indicating both an ECG measurement rate higher than 80.0 % and a large amplitude during motion were selected as the optimal electrode locations. The results of this analysis show four electrode locations with consistently higher ECG measurement rates and larger amplitudes amongst the 56 locations. These four locations were abstracted to be least affected by wearer movement in this research. Based on this result, a design of the garment-formed ECG monitoring platform

  2. PIC microcontroller-based RF wireless ECG monitoring system.

    Science.gov (United States)

    Oweis, R J; Barhoum, A

    2007-01-01

    This paper presents a radio-telemetry system that provides the possibility of ECG signal transmission from a patient detection circuit via an RF data link. A PC then receives the signal through the National Instrument data acquisition card (NIDAQ). The PC is equipped with software allowing the received ECG signals to be saved, analysed, and sent by email to another part of the world. The proposed telemetry system consists of a patient unit and a PC unit. The amplified and filtered ECG signal is sampled 360 times per second, and the A/D conversion is performed by a PIC16f877 microcontroller. The major contribution of the final proposed system is that it detects, processes and sends patients ECG data over a wireless RF link to a maximum distance of 200 m. Transmitted ECG data with different numbers of samples were received, decoded by means of another PIC microcontroller, and displayed using MATLAB program. The designed software is presented in a graphical user interface utility.

  3. A wearable 12-lead ECG acquisition system with fabric electrodes.

    Science.gov (United States)

    Haoshi Zhang; Lan Tian; Huiyang Lu; Ming Zhou; Haiqing Zou; Peng Fang; Fuan Yao; Guanglin Li

    2017-07-01

    Continuous electrocardiogram (ECG) monitoring is significant for prevention of heart disease and is becoming an important part of personal and family health care. In most of the existing wearable solutions, conventional metal sensors and corresponding chips are simply integrated into clothes and usually could only collect few leads of ECG signals that could not provide enough information for diagnosis of cardiac diseases such as arrhythmia and myocardial ischemia. In this study, a wearable 12-lead ECG acquisition system with fabric electrodes was developed and could simultaneously process 12 leads of ECG signals. By integrating the fabric electrodes into a T-shirt, the wearable system would provide a comfortable and convenient user interface for ECG recording. For comparison, the proposed fabric electrode and the gelled traditional metal electrodes were used to collect ECG signals on a subject, respectively. The approximate entropy (ApEn) of ECG signals from both types of electrodes were calculated. The experimental results show that the fabric electrodes could achieve similar performance as the gelled metal electrodes. This preliminary work has demonstrated that the developed ECG system with fabric electrodes could be utilized for wearable health management and telemedicine applications.

  4. Biometric and Emotion Identification: An ECG Compression Based Method

    Directory of Open Access Journals (Sweden)

    Susana Brás

    2018-04-01

    Full Text Available We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG. The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1 conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2 conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3 identification of the ECG record class, using a 1-NN (nearest neighbor classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model.

  5. Biometric and Emotion Identification: An ECG Compression Based Method

    Science.gov (United States)

    Brás, Susana; Ferreira, Jacqueline H. T.; Soares, Sandra C.; Pinho, Armando J.

    2018-01-01

    We present an innovative and robust solution to both biometric and emotion identification using the electrocardiogram (ECG). The ECG represents the electrical signal that comes from the contraction of the heart muscles, indirectly representing the flow of blood inside the heart, it is known to convey a key that allows biometric identification. Moreover, due to its relationship with the nervous system, it also varies as a function of the emotional state. The use of information-theoretic data models, associated with data compression algorithms, allowed to effectively compare ECG records and infer the person identity, as well as emotional state at the time of data collection. The proposed method does not require ECG wave delineation or alignment, which reduces preprocessing error. The method is divided into three steps: (1) conversion of the real-valued ECG record into a symbolic time-series, using a quantization process; (2) conditional compression of the symbolic representation of the ECG, using the symbolic ECG records stored in the database as reference; (3) identification of the ECG record class, using a 1-NN (nearest neighbor) classifier. We obtained over 98% of accuracy in biometric identification, whereas in emotion recognition we attained over 90%. Therefore, the method adequately identify the person, and his/her emotion. Also, the proposed method is flexible and may be adapted to different problems, by the alteration of the templates for training the model. PMID:29670564

  6. The Development of a Portable ECG Monitor Based on DSP

    Science.gov (United States)

    Nan, CHI Jian; Tao, YAN Yan; Meng Chen, LIU; Li, YANG

    With the advent of global information, researches of Smart Home system are in the ascendant, the ECG real-time detection, and wireless transmission of ECG become more useful. In order to achieve the purpose we developed a portable ECG monitor which achieves the purpose of cardiac disease remote monitoring, and will be used in the physical and psychological disease surveillance in smart home system, we developed this portable ECG Monitor, based on the analysis of existing ECG Monitor, using TMS320F2812 as the core controller, which complete the signal collection, storage, processing, waveform display and transmission.

  7. An ECG simulator for generating maternal-foetal activity mixtures on abdominal ECG recordings

    International Nuclear Information System (INIS)

    Behar, Joachim; Andreotti, Fernando; Li, Qiao; Oster, Julien; Clifford, Gari D; Zaunseder, Sebastian

    2014-01-01

    Accurate foetal electrocardiogram (FECG) morphology extraction from non-invasive sensors remains an open problem. This is partly due to the paucity of available public databases. Even when gold standard information (i.e derived from the scalp electrode) is present, the collection of FECG can be problematic, particularly during stressful or clinically important events. In order to address this problem we have introduced an FECG simulator based on earlier work on foetal and adult ECG modelling. The open source foetal ECG synthetic simulator, fecgsyn, is able to generate maternal-foetal ECG mixtures with realistic amplitudes, morphology, beat-to-beat variability, heart rate changes and noise. Positional (rotation and translation-related) movements in the foetal and maternal heart due to respiration, foetal activity and uterine contractions were also added to the simulator. The simulator was used to generate some of the signals that were part of the 2013 PhysioNet Computing in Cardiology Challenge dataset and has been posted on Physionet.org (together with scripts to generate realistic scenarios) under an open source license. The toolbox enables further research in the field and provides part of a standard for industry and regulatory testing of rare pathological scenarios. (paper)

  8. Usefulness of exercise ECG test with nitroglycerin and exercise cardiac scintigraphy in patients with false positive exercise ECG test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro

    1984-01-01

    The purpose of this study is to evaluate the clinical usefulness of exercise (Ex) ECG test with sublingual nitroglycerin (NTG) and Ex cardiac scintigraphy in differentiating false positive responses from true positive responses of Ex ECG test. We examined 7 pts (age : 46+-7 years) with true positive Ex ECG test (TP) and 8 pts (age : 55+-10 years) with false positive Ex ECG test (FP). TP had significant coronary artery disease and FP did not. Ex test was done by multistage ergometer test. In 5 pts of TP and all pts of FP, Ex cardiac scintigraphy was performed. In TP, Ex cardiac scintigraphy revealed reversible perfusion deficit, but not in FP. NTG was administered 3 minutes before Ex test was started. Ex test with NTG was terminated at the same load as Ex test without NTG. Pressure-rate products at the end point of Ex test did not show significant difference between Ex test without NTG and that with NTG (TP: 203x10 2 , 213x10 2 , FP: 196x10 2 , 206x10 2 , respectively). In 7 pts of FP, ST depression in Ex test without NTG was not improved in Ex test with NTG. On the other hand, in all pts of TP, ST depression seen in Ex test without NTG, was not observed in Ex test with NTG. It may be concluded that Ex cardiac scintigraphy is diagnostic for differentiation of false positive responses from true positive responses of Ex ECG test, as well as Ex ECG test with NTG is. (author)

  9. Enhancement of Twins Fetal ECG Signal Extraction Based on Hybrid Blind Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Ahmed Kareem Abdullah

    2017-07-01

    Full Text Available ECG machines are noninvasive system used to measure the heartbeat signal. It’s very important to monitor the fetus ECG signals during pregnancy to check the heat activity and to detect any problem early before born, therefore the monitoring of ECG signals have clinical significance and importance. For multi-fetal pregnancy case the classical filtering algorithms are not sufficient to separate the ECG signals between mother and fetal. In this paper the mixture consists of mixing from three ECG signals, the first signal is the mother ECG (M-ECG signal, second signal the Fetal-1 ECG (F1-ECG, and third signal is the Fetal-2 ECG (F2-ECG, these signals are extracted based on modified blind source extraction (BSE techniques. The proposed work based on hybridization between two BSE techniques to ensure that the extracted signals separated well. The results demonstrate that the proposed work very efficiently to extract the useful ECG signals

  10. From Pacemaker to Wearable: Techniques for ECG Detection Systems.

    Science.gov (United States)

    Kumar, Ashish; Komaragiri, Rama; Kumar, Manjeet

    2018-01-11

    With the alarming rise in the deaths due to cardiovascular diseases (CVD), present medical research scenario places notable importance on techniques and methods to detect CVDs. As adduced by world health organization, technological proceeds in the field of cardiac function assessment have become the nucleus and heart of all leading research studies in CVDs in which electrocardiogram (ECG) analysis is the most functional and convenient tool used to test the range of heart-related irregularities. Most of the approaches present in the literature of ECG signal analysis consider noise removal, rhythm-based analysis, and heartbeat detection to improve the performance of a cardiac pacemaker. Advancements achieved in the field of ECG segments detection and beat classification have a limited evaluation and still require clinical approvals. In this paper, approaches on techniques to implement on-chip ECG detector for a cardiac pacemaker system are discussed. Moreover, different challenges regarding the ECG signal morphology analysis deriving from medical literature is extensively reviewed. It is found that robustness to noise, wavelet parameter choice, numerical efficiency, and detection performance are essential performance indicators required by a state-of-the-art ECG detector. Furthermore, many algorithms described in the existing literature are not verified using ECG data from the standard databases. Some ECG detection algorithms show very high detection performance with the total number of detected QRS complexes. However, the high detection performance of the algorithm is verified using only a few datasets. Finally, gaps in current advancements and testing are identified, and the primary challenge remains to be implementing bullseye test for morphology analysis evaluation.

  11. Bivariate empirical mode decomposition for ECG-based biometric identification with emotional data.

    Science.gov (United States)

    Ferdinando, Hany; Seppanen, Tapio; Alasaarela, Esko

    2017-07-01

    Emotions modulate ECG signals such that they might affect ECG-based biometric identification in real life application. It motivated in finding good feature extraction methods where the emotional state of the subjects has minimum impacts. This paper evaluates feature extraction based on bivariate empirical mode decomposition (BEMD) for biometric identification when emotion is considered. Using the ECG signal from the Mahnob-HCI database for affect recognition, the features were statistical distributions of dominant frequency after applying BEMD analysis to ECG signals. The achieved accuracy was 99.5% with high consistency using kNN classifier in 10-fold cross validation to identify 26 subjects when the emotional states of the subjects were ignored. When the emotional states of the subject were considered, the proposed method also delivered high accuracy, around 99.4%. We concluded that the proposed method offers emotion-independent features for ECG-based biometric identification. The proposed method needs more evaluation related to testing with other classifier and variation in ECG signals, e.g. normal ECG vs. ECG with arrhythmias, ECG from various ages, and ECG from other affective databases.

  12. A method of ECG template extraction for biometrics applications.

    Science.gov (United States)

    Zhou, Xiang; Lu, Yang; Chen, Meng; Bao, Shu-Di; Miao, Fen

    2014-01-01

    ECG has attracted widespread attention as one of the most important non-invasive physiological signals in healthcare-system related biometrics for its characteristics like ease-of-monitoring, individual uniqueness as well as important clinical value. This study proposes a method of dynamic threshold setting to extract the most stable ECG waveform as the template for the consequent ECG identification process. With the proposed method, the accuracy of ECG biometrics using the dynamic time wraping for difference measures has been significantly improved. Analysis results with the self-built electrocardiogram database show that the deployment of the proposed method was able to reduce the half total error rate of the ECG biometric system from 3.35% to 1.45%. Its average running time on the platform of android mobile terminal was around 0.06 seconds, and thus demonstrates acceptable real-time performance.

  13. Global patterns of evolutionary distinct and globally endangered amphibians and mammals.

    Science.gov (United States)

    Safi, Kamran; Armour-Marshall, Katrina; Baillie, Jonathan E M; Isaac, Nick J B

    2013-01-01

    Conservation of phylogenetic diversity allows maximising evolutionary information preserved within fauna and flora. The "EDGE of Existence" programme is the first institutional conservation initiative that prioritises species based on phylogenetic information. Species are ranked in two ways: one according to their evolutionary distinctiveness (ED) and second, by including IUCN extinction status, their evolutionary distinctiveness and global endangerment (EDGE). Here, we describe the global patterns in the spatial distribution of priority ED and EDGE species, in order to identify conservation areas for mammalian and amphibian communities. In addition, we investigate whether environmental conditions can predict the observed spatial pattern in ED and EDGE globally. Priority zones with high concentrations of ED and EDGE scores were defined using two different methods. The overlap between mammal and amphibian zones was very small, reflecting the different phylo-biogeographic histories. Mammal ED zones were predominantly found on the African continent and the neotropical forests, whereas in amphibians, ED zones were concentrated in North America. Mammal EDGE zones were mainly in South-East Asia, southern Africa and Madagascar; for amphibians they were in central and south America. The spatial pattern of ED and EDGE was poorly described by a suite of environmental variables. Mapping the spatial distribution of ED and EDGE provides an important step towards identifying priority areas for the conservation of mammalian and amphibian phylogenetic diversity in the EDGE of existence programme.

  14. Development of a portable wireless system for bipolar concentric ECG recording

    International Nuclear Information System (INIS)

    Prats-Boluda, G; Ye-Lin, Y; Bueno Barrachina, J M; Senent, E; Rodriguez de Sanabria, R; Garcia-Casado, J

    2015-01-01

    Cardiovascular diseases (CVDs) remain the biggest cause of deaths worldwide. ECG monitoring is a key tool for early diagnosis of CVDs. Conventional monitors use monopolar electrodes resulting in poor spatial resolution surface recordings and requiring extensive wiring. High-spatial resolution surface electrocardiographic recordings provide valuable information for the diagnosis of a wide range of cardiac abnormalities, including infarction and arrhythmia. The aim of this work was to develop and test a wireless recording system for acquiring high spatial resolution ECG signals, based on a flexible tripolar concentric electrode (TCE) without cable wiring or external reference electrode which would make more comnfortable its use in clinical practice. For this, a portable, wireless sensor node for analogue conditioning, digitalization and transmission of a bipolar concentric ECG signal (BC-ECG) using a TCE and a Mason-likar Lead-I ECG (ML-Lead-I ECG) signal was developed. Experimental results from a total of 32 healthy volunteers showed that the ECG fiducial points in the BC-ECG signals, recorded with external and internal reference electrode, are consistent with those of simultaneous ML-Lead-I ECG. No statistically significant difference was found in either signal amplitude or morphology, regardless of the reference electrode used, being the signal-to-noise similar to that of ML-Lead-I ECG. Furthermore, it has been observed that BC-ECG signals contain information that could not available in conventional records, specially related to atria activity. The proposed wireless sensor node provides non-invasive high-local resolution ECG signals using only a TCE without additional wiring, which would have great potential in medical diagnosis of diseases such as atrial or ventricular fibrillations or arrhythmias that currently require invasive diagnostic procedures (catheterization). (paper)

  15. FastICA peel-off for ECG interference removal from surface EMG.

    Science.gov (United States)

    Chen, Maoqi; Zhang, Xu; Chen, Xiang; Zhu, Mingxing; Li, Guanglin; Zhou, Ping

    2016-06-13

    Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surface EMG signals. Although demonstrating spatial variability in waveform shape, the ECG interference in different channels shares the same firing instants. Utilizing the firing information estimated from FastICA, ECG interference can be separated from surface EMG by a "peel off" processing. The performance of the method was quantified with synthetic signals by combining a series of experimentally recorded "clean" surface EMG and "pure" ECG interference. It was demonstrated that the new method can remove ECG interference efficiently with little distortion to surface EMG amplitude and frequency. The proposed method was also validated using experimental surface EMG signals contaminated by ECG interference. The proposed FastICA peel-off method can be used as a new and practical solution to eliminating ECG interference from multichannel EMG recordings.

  16. [Study for portable dynamic ECG monitor and recorder].

    Science.gov (United States)

    Yang, Pengcheng; Li, Yongqin; Chen, Bihua

    2012-09-01

    This Paper presents a portable dynamic ECG monitor system based on MSP430F149 microcontroller. The electrocardiogram detecting system consists of ECG detecting circuit, man-machine interaction module, MSP430F149 and upper computer software. The ECG detecting circuit including a preamplifier, second-order Butterworth low-pass filter, high-pass filter, and 50Hz trap circuit to detects electrocardiogram and depresses various kinds of interference effectively. A microcontroller is used to collect three channel analog signals which can be displayed on TFT LCD. A SD card is used to record real-time data continuously and implement the FTA16 file system. In the end, a host computer system interface is also designed to analyze the ECG signal and the analysis results can provide diagnosis references to clinical doctors.

  17. Extraction of ECG signal with adaptive filter for hearth abnormalities detection

    Science.gov (United States)

    Turnip, Mardi; Saragih, Rijois. I. E.; Dharma, Abdi; Esti Kusumandari, Dwi; Turnip, Arjon; Sitanggang, Delima; Aisyah, Siti

    2018-04-01

    This paper demonstrates an adaptive filter method for extraction ofelectrocardiogram (ECG) feature in hearth abnormalities detection. In particular, electrocardiogram (ECG) is a recording of the heart's electrical activity by capturing a tracingof cardiac electrical impulse as it moves from the atrium to the ventricles. The applied algorithm is to evaluate and analyze ECG signals for abnormalities detection based on P, Q, R and S peaks. In the first phase, the real-time ECG data is acquired and pre-processed. In the second phase, the procured ECG signal is subjected to feature extraction process. The extracted features detect abnormal peaks present in the waveform. Thus the normal and abnormal ECG signal could be differentiated based on the features extracted.

  18. Improving ECG classification accuracy using an ensemble of neural network modules.

    Directory of Open Access Journals (Sweden)

    Mehrdad Javadi

    Full Text Available This paper illustrates the use of a combined neural network model based on Stacked Generalization method for classification of electrocardiogram (ECG beats. In conventional Stacked Generalization method, the combiner learns to map the base classifiers' outputs to the target data. We claim adding the input pattern to the base classifiers' outputs helps the combiner to obtain knowledge about the input space and as the result, performs better on the same task. Experimental results support our claim that the additional knowledge according to the input space, improves the performance of the proposed method which is called Modified Stacked Generalization. In particular, for classification of 14966 ECG beats that were not previously seen during training phase, the Modified Stacked Generalization method reduced the error rate for 12.41% in comparison with the best of ten popular classifier fusion methods including Max, Min, Average, Product, Majority Voting, Borda Count, Decision Templates, Weighted Averaging based on Particle Swarm Optimization and Stacked Generalization.

  19. Near Field Communication-based telemonitoring with integrated ECG recordings.

    Science.gov (United States)

    Morak, J; Kumpusch, H; Hayn, D; Leitner, M; Scherr, D; Fruhwald, F M; Schreier, G

    2011-01-01

    Telemonitoring of vital signs is an established option in treatment of patients with chronic heart failure (CHF). In order to allow for early detection of atrial fibrillation (AF) which is highly prevalent in the CHF population telemonitoring programs should include electrocardiogram (ECG) signals. It was therefore the aim to extend our current home monitoring system based on mobile phones and Near Field Communication technology (NFC) to enable patients acquiring their ECG signals autonomously in an easy-to-use way. We prototypically developed a sensing device for the concurrent acquisition of blood pressure and ECG signals. The design of the device equipped with NFC technology and Bluetooth allowed for intuitive interaction with a mobile phone based patient terminal. This ECG monitoring system was evaluated in the course of a clinical pilot trial to assess the system's technical feasibility, usability and patient's adherence to twice daily usage. 21 patients (4f, 54 ± 14 years) suffering from CHF were included in the study and were asked to transmit two ECG recordings per day via the telemonitoring system autonomously over a monitoring period of seven days. One patient dropped out from the study. 211 data sets were transmitted over a cumulative monitoring period of 140 days (overall adherence rate 82.2%). 55% and 8% of the transmitted ECG signals were sufficient for ventricular and atrial rhythm assessment, respectively. Although ECG signal quality has to be improved for better AF detection the developed communication design of joining Bluetooth and NFC technology in our telemonitoring system allows for ambulatory ECG acquisition with high adherence rates and system usability in heart failure patients.

  20. Deep ECGNet: An Optimal Deep Learning Framework for Monitoring Mental Stress Using Ultra Short-Term ECG Signals.

    Science.gov (United States)

    Hwang, Bosun; You, Jiwoo; Vaessen, Thomas; Myin-Germeys, Inez; Park, Cheolsoo; Zhang, Byoung-Tak

    2018-02-08

    Stress recognition using electrocardiogram (ECG) signals requires the intractable long-term heart rate variability (HRV) parameter extraction process. This study proposes a novel deep learning framework to recognize the stressful states, the Deep ECGNet, using ultra short-term raw ECG signals without any feature engineering methods. The Deep ECGNet was developed through various experiments and analysis of ECG waveforms. We proposed the optimal recurrent and convolutional neural networks architecture, and also the optimal convolution filter length (related to the P, Q, R, S, and T wave durations of ECG) and pooling length (related to the heart beat period) based on the optimization experiments and analysis on the waveform characteristics of ECG signals. The experiments were also conducted with conventional methods using HRV parameters and frequency features as a benchmark test. The data used in this study were obtained from Kwangwoon University in Korea (13 subjects, Case 1) and KU Leuven University in Belgium (9 subjects, Case 2). Experiments were designed according to various experimental protocols to elicit stressful conditions. The proposed framework to recognize stress conditions, the Deep ECGNet, outperformed the conventional approaches with the highest accuracy of 87.39% for Case 1 and 73.96% for Case 2, respectively, that is, 16.22% and 10.98% improvements compared with those of the conventional HRV method. We proposed an optimal deep learning architecture and its parameters for stress recognition, and the theoretical consideration on how to design the deep learning structure based on the periodic patterns of the raw ECG data. Experimental results in this study have proved that the proposed deep learning model, the Deep ECGNet, is an optimal structure to recognize the stress conditions using ultra short-term ECG data.

  1. ECG Markers of Hemodynamic Improvement in Patients with Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    Marcin Waligóra

    2018-01-01

    Full Text Available Introduction. Several diagnostic tests have been recommended for risk assessment in pulmonary hypertension (PH, but the role of electrocardiography (ECG in monitoring of PH patients has not been yet established. Therefore the aim of the study was to evaluate which ECG patterns characteristic for pulmonary hypertension can predict hemodynamic improvement in patients treated with targeted therapies. Methods. Consecutive patients with pulmonary arterial hypertension (PAH or chronic thromboembolic pulmonary hypertension (CTEPH were eligible to be included if they had had performed two consecutive right heart catheterization (RHC procedures before and after starting of targeted therapies. Patients were followed up from June 2009 to July 2017. ECG patterns of right ventricular hypertrophy according to American College of Cardiology Foundation were assessed. Results. We enrolled 80 patients with PAH and 11 patients with inoperable CTEPH. The follow-up RHC was performed within 12.6±10.0 months after starting therapy. Based on median change of pulmonary vascular resistance, we divided our patients into two subgroups: with and without significant hemodynamic improvement. RV1, max⁡RV1,2 + max⁡SI,aVL-SV1, and PII improved along with the improvement of hemodynamic parameters including PVR. They predicted hemodynamic improvement with similarly good accuracy as shown in ROC analysis: RV1 (AUC: 0.75; 95% CI: 0.63–0.84, PII (AUC: 0.67, 95% CI: 0.56–0.77, and max⁡RV1,2+max⁡SI,aVL-SV1 (0.73; 95% CI: 0.63–0.82. In Cox regression only change in RV1 remained significant mortality predictor (HR: 1.12, 95% CI: 1.01–1.24. Conclusion. Electrocardiogram may be useful in predicting hemodynamic effects of targeted therapy in precapillary pulmonary hypertension. Decrease of RV1, max⁡RV1,2+max⁡SI,aVL-SV1, and PII corresponds with hemodynamic improvement after treatment. Of these changes a decrease of R wave amplitude in V1 is associated with better

  2. [Implementation of ECG Monitoring System Based on Internet of Things].

    Science.gov (United States)

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  3. QRS detection based ECG quality assessment

    International Nuclear Information System (INIS)

    Hayn, Dieter; Jammerbund, Bernhard; Schreier, Günter

    2012-01-01

    Although immediate feedback concerning ECG signal quality during recording is useful, up to now not much literature describing quality measures is available. We have implemented and evaluated four ECG quality measures. Empty lead criterion (A), spike detection criterion (B) and lead crossing point criterion (C) were calculated from basic signal properties. Measure D quantified the robustness of QRS detection when applied to the signal. An advanced Matlab-based algorithm combining all four measures and a simplified algorithm for Android platforms, excluding measure D, were developed. Both algorithms were evaluated by taking part in the Computing in Cardiology Challenge 2011. Each measure's accuracy and computing time was evaluated separately. During the challenge, the advanced algorithm correctly classified 93.3% of the ECGs in the training-set and 91.6 % in the test-set. Scores for the simplified algorithm were 0.834 in event 2 and 0.873 in event 3. Computing time for measure D was almost five times higher than for other measures. Required accuracy levels depend on the application and are related to computing time. While our simplified algorithm may be accurate for real-time feedback during ECG self-recordings, QRS detection based measures can further increase the performance if sufficient computing power is available. (paper)

  4. ECG fiducial point extraction using switching Kalman filter.

    Science.gov (United States)

    Akhbari, Mahsa; Ghahjaverestan, Nasim Montazeri; Shamsollahi, Mohammad B; Jutten, Christian

    2018-04-01

    In this paper, we propose a novel method for extracting fiducial points (FPs) of the beats in electrocardiogram (ECG) signals using switching Kalman filter (SKF). In this method, according to McSharry's model, ECG waveforms (P-wave, QRS complex and T-wave) are modeled with Gaussian functions and ECG baselines are modeled with first order auto regressive models. In the proposed method, a discrete state variable called "switch" is considered that affects only the observation equations. We denote a mode as a specific observation equation and switch changes between 7 modes and corresponds to different segments of an ECG beat. At each time instant, the probability of each mode is calculated and compared among two consecutive modes and a path is estimated, which shows the relation of each part of the ECG signal to the mode with the maximum probability. ECG FPs are found from the estimated path. For performance evaluation, the Physionet QT database is used and the proposed method is compared with methods based on wavelet transform, partially collapsed Gibbs sampler (PCGS) and extended Kalman filter. For our proposed method, the mean error and the root mean square error across all FPs are 2 ms (i.e. less than one sample) and 14 ms, respectively. These errors are significantly smaller than those obtained using other methods. The proposed method achieves lesser RMSE and smaller variability with respect to others. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Study of heart-brain interactions through EEG, ECG, and emotions

    Science.gov (United States)

    Ramasamy, Mouli; Varadan, Vijay K.

    2017-04-01

    Neurocardiology is the exploration of neurophysiological, neurological and neuroanatomical facets of neuroscience's influence in cardiology. The paraphernalia of emotions on the heart and brain are premeditated because of the interaction between the central and peripheral nervous system. This is an investigative attempt to study emotion based neurocardiology and the factors that influence this phenomenon. The factors include: interaction between sleep EEG (electroencephalogram) and ECG (electrocardiogram), relationship between emotion and music, psychophysiological coherence between the heart and brain, emotion recognition techniques, and biofeedback mechanisms. Emotions contribute vitally to the mundane life and are quintessential to a numerous biological and everyday-functional modality of a human being. Emotions are best represented through EEG signals, and to a certain extent, can be observed through ECG and body temperature. Confluence of medical and engineering science has enabled the monitoring and discrimination of emotions influenced by happiness, anxiety, distress, excitement and several other factors that influence the thinking patterns and the electrical activity of the brain. Similarly, HRV (Heart Rate Variability) widely investigated for its provision and discerning characteristics towards EEG and the perception in neurocardiology.

  6. Designing ECG-based physical unclonable function for security of wearable devices.

    Science.gov (United States)

    Shihui Yin; Chisung Bae; Sang Joon Kim; Jae-Sun Seo

    2017-07-01

    As a plethora of wearable devices are being introduced, significant concerns exist on the privacy and security of personal data stored on these devices. Expanding on recent works of using electrocardiogram (ECG) as a modality for biometric authentication, in this work, we investigate the possibility of using personal ECG signals as the individually unique source for physical unclonable function (PUF), which eventually can be used as the key for encryption and decryption engines. We present new signal processing and machine learning algorithms that learn and extract maximally different ECG features for different individuals and minimally different ECG features for the same individual over time. Experimental results with a large 741-subject in-house ECG database show that the distributions of the intra-subject (same person) Hamming distance of extracted ECG features and the inter-subject Hamming distance have minimal overlap. 256-b random numbers generated from the ECG features of 648 (out of 741) subjects pass the NIST randomness tests.

  7. ECG changes after a session of regional intraarterial hyperglycemia

    International Nuclear Information System (INIS)

    Korobchenko, Z.A.; Livshits, L.I.

    1988-01-01

    ECG changes after a session of regional intraarterial hyperglycemia (RIH) in 13 patients (the mean age of 49 years) with locally advanced cancer of the tongue, oral mucosa and oropharynx were presented. Taking into account the mean age of patients and the negative ECG time course after a RIH session, the necessity of patients' examination (including ECG after a RIH session and, when indicated, a consultation by a cardiologist) was emphasized

  8. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Bastarrika, Gorka [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Cardiac Imaging Unit, Clinica Univ. de Navarra, Pamplona (Spain)], e-mail: bastarrika@unav.es

    2012-06-15

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 {+-} 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 {+-} 58.3 mL) with respect to ECG-gated CT (142.7 {+-} 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 {+-} 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.

  9. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria; Bastarrika, Gorka

    2012-01-01

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 ± 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 ± 58.3 mL) with respect to ECG-gated CT (142.7 ± 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 ± 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols

  10. Advanced ECG in 2016: is there more than just a tracing?

    Science.gov (United States)

    Reichlin, Tobias; Abächerli, Roger; Twerenbold, Raphael; Kühne, Michael; Schaer, Beat; Müller, Christian; Sticherling, Christian; Osswald, Stefan

    2016-01-01

    The 12-lead electrocardiogram (ECG) is the most frequently used technology in clinical cardiology. It is critical for evidence-based management of patients with most cardiovascular conditions, including patients with acute myocardial infarction, suspected chronic cardiac ischaemia, cardiac arrhythmias, heart failure and implantable cardiac devices. In contrast to many other techniques in cardiology, the ECG is simple, small, mobile, universally available and cheap, and therefore particularly attractive. Standard ECG interpretation mainly relies on direct visual assessment. The progress in biomedical computing and signal processing, and the available computational power offer fascinating new options for ECG analysis relevant to all fields of cardiology. Several digital ECG markers and advanced ECG technologies have shown promise in preliminary studies. This article reviews promising novel surface ECG technologies in three different fields. (1) For the detection of myocardial ischaemia and infarction, QRS morphology feature analysis, the analysis of high frequency QRS components (HF-QRS) and methods using vectorcardiography as well as ECG imaging are discussed. (2) For the identification and management of patients with cardiac arrhythmias, methods of advanced P-wave analysis are discussed and the concept of ECG imaging for noninvasive localisation of cardiac arrhythmias is presented. (3) For risk stratification of sudden cardiac death and the selection of patients for medical device therapy, several novel markers including an automated QRS-score for scar quantification, the QRS-T angle or the T-wave peak-to-end-interval are discussed. Despite the existing preliminary data, none of the advanced ECG markers and technologies has yet accomplished the transition into clinical practice. Further refinement of these technologies and broader validation in large unselected patient cohorts are the critical next step needed to facilitate translation of advanced ECG technologies

  11. Artifact reduction in maternal abdominal ECG recordings for fetal ECG estimation.

    NARCIS (Netherlands)

    Vullings, R.; Peters, C.H.L.; Mischi, M.; Sluijter, R.J.; Oei, S.G.; Bergmans, J.W.M.

    2010-01-01

    Monitoring the fetal electrocardiogram (1ECG) is currently one of the most promising methods to assess fetal health. However, the main problem associated with this method is that the signals recorded from the maternal abdomen are affected by noise and interferences: the maternal electrocardiogram

  12. Robust and Accurate Anomaly Detection in ECG Artifacts Using Time Series Motif Discovery

    Science.gov (United States)

    Sivaraks, Haemwaan

    2015-01-01

    Electrocardiogram (ECG) anomaly detection is an important technique for detecting dissimilar heartbeats which helps identify abnormal ECGs before the diagnosis process. Currently available ECG anomaly detection methods, ranging from academic research to commercial ECG machines, still suffer from a high false alarm rate because these methods are not able to differentiate ECG artifacts from real ECG signal, especially, in ECG artifacts that are similar to ECG signals in terms of shape and/or frequency. The problem leads to high vigilance for physicians and misinterpretation risk for nonspecialists. Therefore, this work proposes a novel anomaly detection technique that is highly robust and accurate in the presence of ECG artifacts which can effectively reduce the false alarm rate. Expert knowledge from cardiologists and motif discovery technique is utilized in our design. In addition, every step of the algorithm conforms to the interpretation of cardiologists. Our method can be utilized to both single-lead ECGs and multilead ECGs. Our experiment results on real ECG datasets are interpreted and evaluated by cardiologists. Our proposed algorithm can mostly achieve 100% of accuracy on detection (AoD), sensitivity, specificity, and positive predictive value with 0% false alarm rate. The results demonstrate that our proposed method is highly accurate and robust to artifacts, compared with competitive anomaly detection methods. PMID:25688284

  13. Dynamics and rate-dependence of the spatial angle between ventricular depolarization and repolarization wave fronts during exercise ECG.

    Science.gov (United States)

    Kenttä, Tuomas; Karsikas, Mari; Kiviniemi, Antti; Tulppo, Mikko; Seppänen, Tapio; Huikuri, Heikki V

    2010-07-01

    QRS/T angle and the cosine of the angle between QRS and T-wave vectors (TCRT), measured from standard 12-lead electrocardiogram (ECG), have been used in risk stratification of patients. This study assessed the possible rate dependence of these variables during exercise ECG in healthy subjects. Forty healthy volunteers, 20 men and 20 women, aged 34.6 +/- 3.4, underwent an exercise ECG testing. Twelve-lead ECG was recorded from each test subject and the spatial QRS/T angle and TCRT were automatically analyzed in a beat-to-beat manner with custom-made software. The individual TCRT/RR and QRST/RR patterns were fitted with seven different regression models, including a linear model and six nonlinear models. TCRT and QRS/T angle showed a significant rate dependence, with decreased values at higher heart rates (HR). In individual subjects, the second-degree polynomic model was the best regression model for TCRT/RR and QRST/RR slopes. It provided the best fit for both exercise and recovery. The overall TCRT/RR and QRST/RR slopes were similar between men and women during exercise and recovery. However, women had predominantly higher TCRT and QRS/T values. With respect to time, the dynamics of TCRT differed significantly between men and women; with a steeper exercise slope in women (women, -0.04/min vs -0.02/min in men, P exercise. The individual patterns of TCRT and QRS/T angle are affected by HR and gender. Delayed rate adaptation creates hysteresis in the TCRT/RR slopes.

  14. Global patterns of evolutionary distinct and globally endangered amphibians and mammals.

    Directory of Open Access Journals (Sweden)

    Kamran Safi

    Full Text Available BACKGROUND: Conservation of phylogenetic diversity allows maximising evolutionary information preserved within fauna and flora. The "EDGE of Existence" programme is the first institutional conservation initiative that prioritises species based on phylogenetic information. Species are ranked in two ways: one according to their evolutionary distinctiveness (ED and second, by including IUCN extinction status, their evolutionary distinctiveness and global endangerment (EDGE. Here, we describe the global patterns in the spatial distribution of priority ED and EDGE species, in order to identify conservation areas for mammalian and amphibian communities. In addition, we investigate whether environmental conditions can predict the observed spatial pattern in ED and EDGE globally. METHODS AND PRINCIPAL FINDINGS: Priority zones with high concentrations of ED and EDGE scores were defined using two different methods. The overlap between mammal and amphibian zones was very small, reflecting the different phylo-biogeographic histories. Mammal ED zones were predominantly found on the African continent and the neotropical forests, whereas in amphibians, ED zones were concentrated in North America. Mammal EDGE zones were mainly in South-East Asia, southern Africa and Madagascar; for amphibians they were in central and south America. The spatial pattern of ED and EDGE was poorly described by a suite of environmental variables. CONCLUSIONS: Mapping the spatial distribution of ED and EDGE provides an important step towards identifying priority areas for the conservation of mammalian and amphibian phylogenetic diversity in the EDGE of existence programme.

  15. A low-power portable ECG sensor interface with dry electrodes

    International Nuclear Information System (INIS)

    Pu Xiaofei; Wan Lei; Zhang Hui; Qin Yajie; Hong Zhiliang

    2013-01-01

    This paper describes a low-power portable sensor interface dedicated to sensing and processing electrocardiogram (ECG) signals. Dry electrodes were employed in this ECG sensor, which eliminates the need of conductive gel and avoids complicated and mandatory skin preparation before electrode attachment. This ECG sensor system consists of two ICs, an analog front-end (AFE) and a successive approximation register analog-to-digital converter (SAR ADC) containing a relaxation oscillator. This proposed design was fabricated in a 0.18 μm 1P6M standard CMOS process. The AFE for extracting the biopotential signals is essential in this ECG sensor. In measurements, the AFE obtains a mid-band gain of 45 dB, a bandwidth from 0.6 to 160 Hz, and a total input referred noise of 2.8 μV rms while consuming 1 μW from the 1.8 V supply. The noise efficiency factor (NEF) of our design is 3.4. After conditioning, the amplified ECG signal is digitized by a 12-bit SAR ADC with 61.8 dB SNDR and 220 fJ/conversion-step. Finally, a complete ECG sensor interface with three dry copper electrodes is demonstrated in real-word setting, showing successful recordings of a capture ECG waveform. (semiconductor integrated circuits)

  16. Low-power analog integrated circuits for wireless ECG acquisition systems.

    Science.gov (United States)

    Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh

    2012-09-01

    This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs.

  17. Diagnostic Role of ECG Recording Simultaneously With EEG Testing.

    Science.gov (United States)

    Kendirli, Mustafa Tansel; Aparci, Mustafa; Kendirli, Nurten; Tekeli, Hakan; Karaoglan, Mustafa; Senol, Mehmet Guney; Togrol, Erdem

    2015-07-01

    Arrhythmia is not uncommon in the etiology of syncope which mimics epilepsy. Data about the epilepsy induced vagal tonus abnormalities have being increasingly reported. So we aimed to evaluate what a neurologist may gain by a simultaneous electrocardiogram (ECG) and electroencephalogram (EEG) recording in the patients who underwent EEG testing due to prediagnosis of epilepsy. We retrospectively evaluated and detected ECG abnormalities in 68 (18%) of 376 patients who underwent EEG testing. A minimum of 20 of minutes artifact-free recording were required for each patient. Standard 1-channel ECG was simultaneously recorded in conjunction with the EEG. In all, 28% of females and 14% of males had ECG abnormalities. Females (mean age 49 years, range 18-88 years) were older compared with the male group (mean age 28 years, range 16-83 years). Atrial fibrillation was more frequent in female group whereas bradycardia and respiratory sinus arrhythmia was higher in male group. One case had been detected a critical asystole indicating sick sinus syndrome in the female group and treated with a pacemaker implantation in the following period. Simultaneous ECG recording in conjunction with EEG testing is a clinical prerequisite to detect and to clarify the coexisting ECG and EEG abnormalities and their clinical relevance. Potentially rare lethal causes of syncope that mimic seizure or those that could cause resistance to antiepileptic therapy could effectively be distinguished by detecting ECG abnormalities coinciding with the signs and abnormalities during EEG recording. © EEG and Clinical Neuroscience Society (ECNS) 2014.

  18. Live ECG readings using Google Glass in emergency situations.

    Science.gov (United States)

    Schaer, Roger; Salamin, Fanny; Jimenez Del Toro, Oscar Alfonso; Atzori, Manfredo; Muller, Henning; Widmer, Antoine

    2015-01-01

    Most sudden cardiac problems require rapid treatment to preserve life. In this regard, electrocardiograms (ECG) shown on vital parameter monitoring systems help medical staff to detect problems. In some situations, such monitoring systems may display information in a less than convenient way for medical staff. For example, vital parameters are displayed on large screens outside the field of view of a surgeon during cardiac surgery. This may lead to losing time and to mistakes when problems occur during cardiac operations. In this paper we present a novel approach to display vital parameters such as the second derivative of the ECG rhythm and heart rate close to the field of view of a surgeon using Google Glass. As a preliminary assessment, we run an experimental study to verify the possibility for medical staff to identify abnormal ECG rhythms from Google Glass. This study compares 6 ECG rhythms readings from a 13.3 inch laptop screen and from the prism of Google Glass. Seven medical residents in internal medicine participated in the study. The preliminary results show that there is no difference between identifying these 6 ECG rhythms from the laptop screen versus Google Glass. Both allow close to perfect identification of the 6 common ECG rhythms. This shows the potential of connected glasses such as Google Glass to be useful in selected medical applications.

  19. Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (''ECG pulsing''): phantom measurements

    International Nuclear Information System (INIS)

    Poll, L.W.; Cohnen, M.; Brachten, S.; Moedder, U.; Ewen, K.

    2002-01-01

    To evaluate the effect of ECG-controlled tube current modulation on radiation exposure in retrospectively-ECG-gated multislice CT (MSCT) of the heart. Material and methods: Three different cardiac MSCT protocols with different slice collimation (4 x 1, and 4 x 2.5 mm), and a pitch-factor of 1.5 and 1.8 were investigated at a multi-slice CT scanner Somatom Volume Zoom, Siemens. An anthropomorphic Alderson-Rando phantom was equipped with LiF-Thermoluminescence dosimeters at several organ sites, and effective doses were calculated using ICRP-weighting factors. Scan protocols were performed with ECG-controlled tube current modulation ('ECG pulsing') at two different heart rates (60 and 80 bpm). These data were compared to previous data from MSCT of the heart without use of 'ECG pulsing'. Results: Radiation exposure with (60 bpm) and without tube current modulation using a 2.5 mm collimation was 1.8 mSv and 2.9 mSv for females, and 1.5 mSv and 2.4 mSv for males, respectively. For protocols using a 1 mm collimation with a pitch-factor of 1.5 (1.8), radiation exposure with and without tube current modulation was 5.6 (6.3) mSv and 9.5 (11.2) mSv for females, and 4.6 (5.2) mSv and 7.7 (9.2) mSv for males, respectively. At higher heart rates (80 bpm) radiation exposure is increased from 1.5-1.8 mSv to 1.8-2.1 mSv, using the 2.5 mm collimation, and from 4.6-5.6 mSv to 5.9-7.2 mSv, for protocols using 1 mm collimation. Conclusions: The ECG-controlled tube current modulation allows a dose reduction of 37% to 44% when retrospectively ECG-gated MSCT of the heart is performed. The tube current - as a function over time - and therefore the radiation exposure is dependent on the heart rate. (orig.) [de

  20. Threshold-based system for noise detection in multilead ECG recordings

    International Nuclear Information System (INIS)

    Jekova, Irena; Krasteva, Vessela; Christov, Ivaylo; Abächerli, Roger

    2012-01-01

    This paper presents a system for detection of the most common noise types seen on the electrocardiogram (ECG) in order to evaluate whether an episode from 12-lead ECG is reliable for diagnosis. It implements criteria for estimation of the noise corruption level in specific frequency bands, aiming to identify the main sources of ECG quality disruption, such as missing signal or limited dynamics of the QRS components above 4 Hz; presence of high amplitude and steep artifacts seen above 1 Hz; baseline drift estimated at frequencies below 1 Hz; power–line interference in a band ±2 Hz around its central frequency; high-frequency and electromyographic noises above 20 Hz. All noise tests are designed to process the ECG series in the time domain, including 13 adjustable thresholds for amplitude and slope criteria which are evaluated in adjustable time intervals, as well as number of leads. The system allows flexible extension toward application-specific requirements for the noise levels in acceptable quality ECGs. Training of different thresholds’ settings to determine different positive noise detection rates is performed with the annotated set of 1000 ECGs from the PhysioNet database created for the Computing in Cardiology Challenge 2011. Two implementations are highlighted on the receiver operating characteristic (area 0.968) to fit to different applications. The implementation with high sensitivity (Se = 98.7%, Sp = 80.9%) appears as a reliable alarm when there are any incidental problems with the ECG acquisition, while the implementation with high specificity (Sp = 97.8%, Se = 81.8%) is less susceptible to transient problems but rather validates noisy ECGs with acceptable quality during a small portion of the recording. (paper)

  1. Multistage principal component analysis based method for abdominal ECG decomposition

    International Nuclear Information System (INIS)

    Petrolis, Robertas; Krisciukaitis, Algimantas; Gintautas, Vladas

    2015-01-01

    Reflection of fetal heart electrical activity is present in registered abdominal ECG signals. However this signal component has noticeably less energy than concurrent signals, especially maternal ECG. Therefore traditionally recommended independent component analysis, fails to separate these two ECG signals. Multistage principal component analysis (PCA) is proposed for step-by-step extraction of abdominal ECG signal components. Truncated representation and subsequent subtraction of cardio cycles of maternal ECG are the first steps. The energy of fetal ECG component then becomes comparable or even exceeds energy of other components in the remaining signal. Second stage PCA concentrates energy of the sought signal in one principal component assuring its maximal amplitude regardless to the orientation of the fetus in multilead recordings. Third stage PCA is performed on signal excerpts representing detected fetal heart beats in aim to perform their truncated representation reconstructing their shape for further analysis. The algorithm was tested with PhysioNet Challenge 2013 signals and signals recorded in the Department of Obstetrics and Gynecology, Lithuanian University of Health Sciences. Results of our method in PhysioNet Challenge 2013 on open data set were: average score: 341.503 bpm 2 and 32.81 ms. (paper)

  2. One-Dimensional Signal Extraction Of Paper-Written ECG Image And Its Archiving

    Science.gov (United States)

    Zhang, Zhi-ni; Zhang, Hong; Zhuang, Tian-ge

    1987-10-01

    A method for converting paper-written electrocardiograms to one dimensional (1-D) signals for archival storage on floppy disk is presented here. Appropriate image processing techniques were employed to remove the back-ground noise inherent to ECG recorder charts and to reconstruct the ECG waveform. The entire process consists of (1) digitization of paper-written ECGs with an image processing system via a TV camera; (2) image preprocessing, including histogram filtering and binary image generation; (3) ECG feature extraction and ECG wave tracing, and (4) transmission of the processed ECG data to IBM-PC compatible floppy disks for storage and retrieval. The algorithms employed here may also be used in the recognition of paper-written EEG or EMG and may be useful in robotic vision.

  3. ECG-triggered MDR-CT for the detection of pulmonary metastases

    International Nuclear Information System (INIS)

    Pauls, S.; Wahl, J.; Aschoff, A.J.; Brambs, H.J.; Fleiter, T.R.

    2003-01-01

    Purpose: Comparison of multidetector-row CT (MDR-CT) of the chest with and without ECG triggering for the detection of pulmonary metastases. Materials and Methods: Fifty patients with malignant tumors underwent CT of the chest. The unenhanced phase was performed with ECG-triggered MDR-CT and the contrast-enhanced phase with helical MDR-CT. The ECG-triggered and standard helical scans were interpreted in separate sessions, with the analysis determining the number and demarcation of the intrapulmonary nodules and the delineation of the mediastinal structure (rated 1 = excellent to 5 = poor). Results: ECG-MDR-CT images detected 38% more pulmonary nodules than MDR-CT. The detection rate for tumors [de

  4. ECG Identification System Using Neural Network with Global and Local Features

    Science.gov (United States)

    Tseng, Kuo-Kun; Lee, Dachao; Chen, Charles

    2016-01-01

    This paper proposes a human identification system via extracted electrocardiogram (ECG) signals. Two hierarchical classification structures based on global shape feature and local statistical feature is used to extract ECG signals. Global shape feature represents the outline information of ECG signals and local statistical feature extracts the…

  5. Heart rhythm analysis using ECG recorded with a novel sternum based patch technology

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Fauerskov, Inge; Osmanagic, Armin

    2013-01-01

    , reliable long-term ECG recordings. The device is designed for high compliance and low patient burden. This novel patch technology is CE approved for ambulatory ECG recording of two ECG channels on the sternum. This paper describes a clinical pilot study regarding the usefulness of these ECG signals...... for heart rhythm analysis. A clinical technician with experience in ECG interpretation selected 200 noise-free 7 seconds ECG segments from 25 different patients. These 200 ECG segments were evaluated by two medical doctors according to their usefulness for heart rhythm analysis. The first doctor considered...... 98.5% of the segments useful for rhythm analysis, whereas the second doctor considered 99.5% of the segments useful for rhythm analysis. The conclusion of this pilot study indicates that two channel ECG recorded on the sternum is useful for rhythm analysis and could be used as input to diagnosis...

  6. Low-cost compact ECG with graphic LCD and phonocardiogram system design.

    Science.gov (United States)

    Kara, Sadik; Kemaloğlu, Semra; Kirbaş, Samil

    2006-06-01

    Till today, many different ECG devices are made in developing countries. In this study, low cost, small size, portable LCD screen ECG device, and phonocardiograph were designed. With designed system, heart sounds that take synchronously with ECG signal are heard as sensitive. Improved system consist three units; Unit 1, ECG circuit, filter and amplifier structure. Unit 2, heart sound acquisition circuit. Unit 3, microcontroller, graphic LCD and ECG signal sending unit to computer. Our system can be used easily in different departments of the hospital, health institution and clinics, village clinic and also in houses because of its small size structure and other benefits. In this way, it is possible that to see ECG signal and hear heart sounds as synchronously and sensitively. In conclusion, heart sounds are heard on the part of both doctor and patient because sounds are given to environment with a tiny speaker. Thus, the patient knows and hears heart sounds him/herself and is acquainted by doctor about healthy condition.

  7. Risk stratifying asymptomatic aortic stenosis: role of the resting 12-lead ECG.

    Science.gov (United States)

    Greve, Anders M

    2014-02-01

    Despite being routinely performed in the clinical follow-up of asymptomatic AS patients, little or no evidence describes the prognostic value of ECG findings in asymptomatic AS populations. This PhD thesis examined the correlates of resting 12-lead ECG variables with echocardiographic measures of AS severity and cardiovascular outcomes in the till date largest cohort (n=1,563) of asymptomatic patients with mild-to-moderate AS. Most importantly, this PhD thesis demonstrated that QRS-duration adds independent predictive value of sudden cardiac death and that the additional presence of ECG LVH/strain for fixed AS severity represents a lethal risk attribute. Finally, ECG abnormalities displayed low/moderate concordance with echocardiographic parameters. This argues that the ECG should be regarded as a separate tool for obtaining prognostically important information. Treatment was not randomized by ECG findings, future studies should therefore examine if and which ECG variables should elicit closer follow-up and/or earlier intervention to improve prognosis in asymptomatic AS populations.

  8. Bedside identification of patients at risk for PVC-induced cardiomyopathy: Is ECG useful?

    Science.gov (United States)

    Garster, Noelle C; Henrikson, Charles A

    2017-07-01

    Premature ventricular complexes (PVCs) are an underrecognized cause of cardiomyopathy. Standard 12-lead electrocardiogram (ECG) has potential to direct attention toward at-risk patients. We performed a single-center, retrospective chart review of 1,240 patients who completed ECG and Holter monitoring at Oregon Health and Science University Hospital between January 1, 2011 and December 31, 2013 to investigate the relationship of PVC frequency on ECG with burden on Holter. Primary outcome measures included PVC quantity on ECG, mean PVC quantity on Holter, and percentage of total beats on Holter recorded as PVCs. High PVC burden was defined as ≥10% of total beats. Weighted mean percentages of total beats on Holter monitor recorded as PVCs were calculated for 0, 1, 2, and ≥3 PVCs on ECG and found to be 1.4% (n = 1,128), 3.5% (n = 32), 4.3% (n = 25), and 16.6% (n = 55), respectively, which represent statistically significant differences (P ECG for ≥10% PVC Holter burden was 58%. Negative predictive value for 0 PVCs on ECG was 98%. The sensitivity and specificity of ECG to identify high PVC burden on Holter was 72% and 93.6%, respectively, when utilizing a positive ECG result as one PVC or more, and 44% and 98.9%, respectively, with ≥3 PVCs on ECG. The positive likelihood ratio corresponding to ≥3 PVCs on ECG was 40. These findings demonstrate that the number of PVCs on ECG can be utilized for quick bedside estimation of high PVC burden. © 2017 Wiley Periodicals, Inc.

  9. Dynamic segmentation and linear prediction for maternal ECG removal in antenatal abdominal recordings

    International Nuclear Information System (INIS)

    Vullings, R; Sluijter, R J; Mischi, M; Bergmans, J W M; Peters, C H L; Oei, S G

    2009-01-01

    Monitoring the fetal heart rate (fHR) and fetal electrocardiogram (fECG) during pregnancy is important to support medical decision making. Before labor, the fHR is usually monitored using Doppler ultrasound. This method is inaccurate and therefore of limited clinical value. During labor, the fHR can be monitored more accurately using an invasive electrode; this method also enables monitoring of the fECG. Antenatally, the fECG and fHR can also be monitored using electrodes on the maternal abdomen. The signal-to-noise ratio of these recordings is, however, low, the maternal electrocardiogram (mECG) being the main interference. Existing techniques to remove the mECG from these non-invasive recordings are insufficiently accurate or do not provide all spatial information of the fECG. In this paper a new technique for mECG removal in antenatal abdominal recordings is presented. This technique operates by the linear prediction of each separate wave in the mECG. Its performance in mECG removal and fHR detection is evaluated by comparison with spatial filtering, adaptive filtering, template subtraction and independent component analysis techniques. The new technique outperforms the other techniques in both mECG removal and fHR detection (by more than 3%)

  10. Validation of a Novel Digital Tool in Automatic Scoring of an Online ECG Examination at an International Cardiology Meeting.

    Science.gov (United States)

    Quinn, Kieran L; Crystal, Eugene; Lashevsky, Ilan; Arouny, Banafsheh; Baranchuk, Adrian

    2016-07-01

    We have previously developed a novel digital tool capable of automatically recognizing correct electrocardiography (ECG) diagnoses in an online exam and demonstrated a significant improvement in diagnostic accuracy when utilizing an inductive-deductive reasoning strategy over a pattern recognition strategy. In this study, we sought to validate these findings from participants at the International Winter Arrhythmia School meeting, one of the foremost electrophysiology events in Canada. Preregistration to the event was sent by e-mail. The exam was administered on day 1 of the conference. Results and analysis were presented the following morning to participants. Twenty-five attendees completed the exam, providing a total of 500 responses to be marked. The online tool accurately identified 195 of a total of 395 (49%) correct responses (49%). In total, 305 responses required secondary manual review, of which 200 were added to the correct responses pool. The overall accuracy of correct ECG diagnosis for all participants was 69% and 84% when using pattern recognition or inductive-deductive strategies, respectively. Utilization of a novel digital tool to evaluate ECG competency can be set up as a workshop at international meetings or educational events. Results can be presented during the sessions to ensure immediate feedback. © 2015 Wiley Periodicals, Inc.

  11. Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology

    Directory of Open Access Journals (Sweden)

    José Vicente Lidón-Roger

    2018-01-01

    Full Text Available Among many of the electrode designs used in electrocardiography (ECG, concentric ring electrodes (CREs are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene polystyrene sulfonate; PEDOT:PSS. Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining

  12. Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology.

    Science.gov (United States)

    Lidón-Roger, José Vicente; Prats-Boluda, Gema; Ye-Lin, Yiyao; Garcia-Casado, Javier; Garcia-Breijo, Eduardo

    2018-01-21

    Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records

  13. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor [University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany)

    2010-08-15

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 {+-} 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI (<25 kg/m{sup 2}: 100 kV, >25 kg/m{sup 2}: 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 {+-} 11.1 bpm, variability 1.0 {+-} 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 {+-} 16.6 bpm, variability 17.9 {+-} 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 {+-} 0.3 and 3.0 {+-} 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  14. A system for intelligent home care ECG upload and priorisation.

    Science.gov (United States)

    D'Angelo, Lorenzo T; Tarita, Eugeniu; Zywietz, Tosja K; Lueth, Tim C

    2010-01-01

    In this contribution, a system for internet based, automated home care ECG upload and priorisation is presented for the first time. It unifies the advantages of existing telemonitoring ECG systems adding functionalities such as automated priorisation and usability for home care. Chronic cardiac diseases are a big group in the geriatric field. Most of them can be easily diagnosed with help of an electrocardiogram. A frequent or long-term ECG analysis allows early diagnosis of e.g. a cardiac infarction. Nevertheless, patients often aren't willing to visit a doctor for prophylactic purposes. Possible solutions of this problem are home care devices, which are used to investigate patients at home without the presence of a doctor on site. As the diffusion of such systems leads to a huge amount of data which has to be managed and evaluated, the presented approach focuses on an easy to use software for ECG upload from home, a web based management application and an algorithm for ECG preanalysis and priorisation.

  15. ECG-gated interventional cardiac reconstruction for non-periodic motion.

    Science.gov (United States)

    Rohkohl, Christopher; Lauritsch, Günter; Biller, Lisa; Hornegger, Joachim

    2010-01-01

    The 3-D reconstruction of cardiac vasculature using C-arm CT is an active and challenging field of research. In interventional environments patients often do have arrhythmic heart signals or cannot hold breath during the complete data acquisition. This important group of patients cannot be reconstructed with current approaches that do strongly depend on a high degree of cardiac motion periodicity for working properly. In a last year's MICCAI contribution a first algorithm was presented that is able to estimate non-periodic 4-D motion patterns. However, to some degree that algorithm still depends on periodicity, as it requires a prior image which is obtained using a simple ECG-gated reconstruction. In this work we aim to provide a solution to this problem by developing a motion compensated ECG-gating algorithm. It is built upon a 4-D time-continuous affine motion model which is capable of compactly describing highly non-periodic motion patterns. A stochastic optimization scheme is derived which minimizes the error between the measured projection data and the forward projection of the motion compensated reconstruction. For evaluation, the algorithm is applied to 5 datasets of the left coronary arteries of patients that have ignored the breath hold command and/or had arrhythmic heart signals during the data acquisition. By applying the developed algorithm the average visibility of the vessel segments could be increased by 27%. The results show that the proposed algorithm provides excellent reconstruction quality in cases where classical approaches fail. The algorithm is highly parallelizable and a clinically feasible runtime of under 4 minutes is achieved using modern graphics card hardware.

  16. New approach to ECG's features recognition involving neural network

    International Nuclear Information System (INIS)

    Babloyantz, A.; Ivanov, V.V.; Zrelov, P.V.

    2001-01-01

    A new approach for the detection of slight changes in the form of the ECG signal is proposed. It is based on the approximation of raw ECG data inside each RR-interval by the expansion in polynomials of special type and on the classification of samples represented by sets of expansion coefficients using a layered feed-forward neural network. The transformation applied provides significantly simpler data structure, stability to noise and to other accidental factors. A by-product of the method is the compression of ECG data with factor 5

  17. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    Directory of Open Access Journals (Sweden)

    Hongqiang Li

    2016-10-01

    Full Text Available Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  18. Disease Classification and Biomarker Discovery Using ECG Data

    Directory of Open Access Journals (Sweden)

    Rong Huang

    2015-01-01

    Full Text Available In the recent decade, disease classification and biomarker discovery have become increasingly important in modern biological and medical research. ECGs are comparatively low-cost and noninvasive in screening and diagnosing heart diseases. With the development of personal ECG monitors, large amounts of ECGs are recorded and stored; therefore, fast and efficient algorithms are called for to analyze the data and make diagnosis. In this paper, an efficient and easy-to-interpret procedure of cardiac disease classification is developed through novel feature extraction methods and comparison of classifiers. Motivated by the observation that the distributions of various measures on ECGs of the diseased group are often skewed, heavy-tailed, or multimodal, we characterize the distributions by sample quantiles which outperform sample means. Three classifiers are compared in application both to all features and to dimension-reduced features by PCA: stepwise discriminant analysis (SDA, SVM, and LASSO logistic regression. It is found that SDA applied to dimension-reduced features by PCA is the most stable and effective procedure, with sensitivity, specificity, and accuracy being 89.68%, 84.62%, and 88.52%, respectively.

  19. Distinctive research patterns on public sector performance measurement of public administration and accounting disciplines

    NARCIS (Netherlands)

    van Helden, G. Jan; Johnsen, Age; Vakkuri, Jarmo

    2008-01-01

    This article explores distinctive research patterns of public administration and accounting disciplines concerning public sector performance measurement (PSPM). Our review shows that accounting researchers from Europe investigate reasons for limited PM use and factors explaining a rational or

  20. ECG-Based Measurements of Drug-induced Repolarization Changes

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed

    The purpose of this thesis is to investigate the abnormal repolarization both in the cellular and the surface ECG along with their relationship. It has been identified that the certain morphological changes of the monophasic action potential are predictor of TdP arrhythmia. Therefore the proporti......The purpose of this thesis is to investigate the abnormal repolarization both in the cellular and the surface ECG along with their relationship. It has been identified that the certain morphological changes of the monophasic action potential are predictor of TdP arrhythmia. Therefore...... the proportional changes of the surface ECG which corresponds to the arrhythmia-triggering MAP morphology is warranted to increase the confidence of determining cardiotoxicity of drugs....

  1. ECG changes in gamma-therapy of esophagus cancer

    International Nuclear Information System (INIS)

    Khajrushev, Zh.A.; Abdrakhmanov, Zh.N.

    1978-01-01

    Effect of ionizing radiation dose distribution with time in gamma therapy of esophagus cancer has been studied on the basis of the results obtained with electrocardiography. 700 persons were examined before treatment and after completing the full course of irradiation, 426 persons were examined repeatedly. Radiation treatment methods used are given. In most cases ECG changes result in the quickened systole rhythm and diffuse changes in the myocardium due to intoxication. ECG changes associated with the irradiation for patients with esophagus cancer amounted to 16%. Frequency of postirradiation ECG changes depends on the position of esophagus area under irradiation. Different variants of mean dose fractionation were the most sparing with respect to the heart

  2. Microprocessor-based simulator of surface ECG signals

    International Nuclear Information System (INIS)

    MartInez, A E; Rossi, E; Siri, L Nicola

    2007-01-01

    In this work, a simulator of surface electrocardiogram recorded signals (ECG) is presented. The device, based on a microcontroller and commanded by a personal computer, produces an analog signal resembling actual ECGs, not only in time course and voltage levels, but also in source impedance. The simulator is a useful tool for electrocardiograph calibration and monitoring, to incorporate as well in educational tasks and in clinical environments for early detection of faulty behaviour

  3. Enhancement of low sampling frequency recordings for ECG biometric matching using interpolation.

    Science.gov (United States)

    Sidek, Khairul Azami; Khalil, Ibrahim

    2013-01-01

    Electrocardiogram (ECG) based biometric matching suffers from high misclassification error with lower sampling frequency data. This situation may lead to an unreliable and vulnerable identity authentication process in high security applications. In this paper, quality enhancement techniques for ECG data with low sampling frequency has been proposed for person identification based on piecewise cubic Hermite interpolation (PCHIP) and piecewise cubic spline interpolation (SPLINE). A total of 70 ECG recordings from 4 different public ECG databases with 2 different sampling frequencies were applied for development and performance comparison purposes. An analytical method was used for feature extraction. The ECG recordings were segmented into two parts: the enrolment and recognition datasets. Three biometric matching methods, namely, Cross Correlation (CC), Percent Root-Mean-Square Deviation (PRD) and Wavelet Distance Measurement (WDM) were used for performance evaluation before and after applying interpolation techniques. Results of the experiments suggest that biometric matching with interpolated ECG data on average achieved higher matching percentage value of up to 4% for CC, 3% for PRD and 94% for WDM. These results are compared with the existing method when using ECG recordings with lower sampling frequency. Moreover, increasing the sample size from 56 to 70 subjects improves the results of the experiment by 4% for CC, 14.6% for PRD and 0.3% for WDM. Furthermore, higher classification accuracy of up to 99.1% for PCHIP and 99.2% for SPLINE with interpolated ECG data as compared of up to 97.2% without interpolation ECG data verifies the study claim that applying interpolation techniques enhances the quality of the ECG data. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  5. Human brain basis of musical rhythm perception: common and distinct neural substrates for meter, tempo, and pattern.

    Science.gov (United States)

    Thaut, Michael H; Trimarchi, Pietro Davide; Parsons, Lawrence M

    2014-06-17

    Rhythm as the time structure of music is composed of distinct temporal components such as pattern, meter, and tempo. Each feature requires different computational processes: meter involves representing repeating cycles of strong and weak beats; pattern involves representing intervals at each local time point which vary in length across segments and are linked hierarchically; and tempo requires representing frequency rates of underlying pulse structures. We explored whether distinct rhythmic elements engage different neural mechanisms by recording brain activity of adult musicians and non-musicians with positron emission tomography (PET) as they made covert same-different discriminations of (a) pairs of rhythmic, monotonic tone sequences representing changes in pattern, tempo, and meter, and (b) pairs of isochronous melodies. Common to pattern, meter, and tempo tasks were focal activities in right, or bilateral, areas of frontal, cingulate, parietal, prefrontal, temporal, and cerebellar cortices. Meter processing alone activated areas in right prefrontal and inferior frontal cortex associated with more cognitive and abstract representations. Pattern processing alone recruited right cortical areas involved in different kinds of auditory processing. Tempo processing alone engaged mechanisms subserving somatosensory and premotor information (e.g., posterior insula, postcentral gyrus). Melody produced activity different from the rhythm conditions (e.g., right anterior insula and various cerebellar areas). These exploratory findings suggest the outlines of some distinct neural components underlying the components of rhythmic structure.

  6. Alexander fractional differential window filter for ECG denoising.

    Science.gov (United States)

    Verma, Atul Kumar; Saini, Indu; Saini, Barjinder Singh

    2018-06-01

    The electrocardiogram (ECG) non-invasively monitors the electrical activities of the heart. During the process of recording and transmission, ECG signals are often corrupted by various types of noises. Minimizations of these noises facilitate accurate detection of various anomalies. In the present paper, Alexander fractional differential window (AFDW) filter is proposed for ECG signal denoising. The designed filter is based on the concept of generalized Alexander polynomial and the R-L differential equation of fractional calculus. This concept is utilized to formulate a window that acts as a forward filter. Thereafter, the backward filter is constructed by reversing the coefficients of the forward filter. The proposed AFDW filter is then obtained by averaging of the forward and backward filter coefficients. The performance of the designed AFDW filter is validated by adding the various type of noise to the original ECG signal obtained from MIT-BIH arrhythmia database. The two non-diagnostic measure, i.e., SNR, MSE, and one diagnostic measure, i.e., wavelet energy based diagnostic distortion (WEDD) have been employed for the quantitative evaluation of the designed filter. Extensive experimentations on all the 48-records of MIT-BIH arrhythmia database resulted in average SNR of 22.014 ± 3.806365, 14.703 ± 3.790275, 13.3183 ± 3.748230; average MSE of 0.001458 ± 0.00028, 0.0078 ± 0.000319, 0.01061 ± 0.000472; and average WEDD value of 0.020169 ± 0.01306, 0.1207 ± 0.061272, 0.1432 ± 0.073588, for ECG signal contaminated by the power line, random, and the white Gaussian noise respectively. A new metric named as morphological power preservation measure (MPPM) is also proposed that account for the power preservance (as indicated by PSD plots) and the QRS morphology. The proposed AFDW filter retained much of the original (clean) signal power without any significant morphological distortion as validated by MPPM measure that were 0

  7. A protocol for a prospective observational study using chest and thumb ECG: transient ECG assessment in stroke evaluation (TEASE) in Sweden.

    Science.gov (United States)

    Magnusson, Peter; Koyi, Hirsh; Mattsson, Gustav

    2018-04-03

    Atrial fibrillation (AF) causes ischaemic stroke and based on risk factor evaluation warrants anticoagulation therapy. In stroke survivors, AF is typically detected with short-term ECG monitoring in the stroke unit. Prolonged continuous ECG monitoring requires substantial resources while insertable cardiac monitors are invasive and costly. Chest and thumb ECG could provide an alternative for AF detection poststroke.The primary objective of our study is to assess the incidence of newly diagnosed AF during 28 days of chest and thumb ECG monitoring in cryptogenic stroke. Secondary objectives are to assess health-related quality of life (HRQoL) using short-form health survey (SF-36) and the feasibility of the Coala Heart Monitor in patients who had a stroke. Stroke survivors in Region Gävleborg, Sweden, will be eligible for the study from October 2017. Patients with a history of ischaemic stroke without documented AF before or during ECG evaluation in the stroke unit will be evaluated by the chest and thumb ECG system Coala Heart Monitor. The monitoring system is connected to a smartphone application which allows for remote monitoring and prompt advice on clinical management. Over a period of 28 days, patients will be monitored two times a day and may activate the ECG recording at symptoms. On completion, the system is returned by mail. This system offers a possibility to evaluate the presence of AF poststroke, but the feasibility of this system in patients who recently suffered from a stroke is unknown. In addition, HRQoL using SF-36 in comparison to Swedish population norms will be assessed. The feasibility of the Coala Heart Monitor will be assessed by a self-developed questionnaire. The study was approved by The Regional Ethical Committee in Uppsala (2017/321). The database will be closed after the last follow-up, followed by statistical analyses, interpretation of results and dissemination to a scientific journal. NCT03301662; Pre-results. © Article author

  8. Brugada-like Precordial ST Elevation on ECG by Anterior Mediastinal Infective Mass Lesion

    Directory of Open Access Journals (Sweden)

    Yuji Nakazato

    2003-07-01

    Full Text Available Several causes are known to induce the right precordial ST elevation mimicking Brugada syndrome. Right ventricular outflow area is assumed to be responsible for such ECG changes. We experienced a case of anterior mediastinal infective mass lesion with a Brugada-like ECG. A 52-year-old female, who has pulmonary stenosis and recurrent episodes of right ventricular heart failure, complained of high fever, abdominal discomfort, and edema. On physical examination, jugular vein dilation, hepatomegaly, and facial and leg edema were noted. Leucocytosis was also noted on blood examination. An ECG showed right ventricular hypertrophy, incomplete right bundle branch block pattern and marked ST elevation on precordial leads mimicking Brugada syndrome. Magnetic resonance imaging revealed an abnormal mass shadow located on the anterior mediastinum and compressing the right ventricle (Figure 1A. Trans-thoracic echocardiography also showed the high echogenic mass lesion at the anterior side of right ventricle and the vicinity of pulmonary valve. After treatment with antibiotics, the mass lesion gradually shrunk. Concomitantly, the ST elevation disappeared with improvement of inflammatory markers (Figure 1B. The symptoms suggesting right ventricular failure were also ameliorated. The mechanism of Brugada-like ST elevation in this patient was considered to be compression, by the abnormal infective mass, of the right ventricular outflow tract with/without focal pericardial inflammation.

  9. Left Ventricular Hypertrophy: An allometric comparative analysis of different ECG markers

    International Nuclear Information System (INIS)

    Bonomini, MP; Valentinuzzi, M E; Arini, P D; Ingallina, F; Barone, V

    2011-01-01

    Allometry, in general biology, measures the relative growth of a part in relation to the whole living organism. Left ventricular hypertrophy (LVH) is the heart adaptation to excessive load (systolic or diastolic). The increase in left ventricular mass leads to an increase in the electrocardiographic voltages. Based on clinical data, we compared the allometric behavior of three different ECG markers of LVH. To do this, the allometric fit AECG δ + β (VM) relating left ventricular mass (estimated from ecocardiographic data) and ECG amplitudes (expressed as the Cornell-Voltage, Sokolow and the ECG overall voltage indexes) were compared. Besides, sensitivity and specificity for each index were analyzed. The more sensitive the ECG criteria, the better the allometric fit. In conclusion: The allometric paradigm should be regarded as the way to design new and more sensitive ECG-based LVH markers.

  10. A Pilot Study Assessing ECG versus ECHO Ventriculoventricular Optimization in Pediatric Resynchronization Patients.

    Science.gov (United States)

    Punn, Rajesh; Hanisch, Debra; Motonaga, Kara S; Rosenthal, David N; Ceresnak, Scott R; Dubin, Anne M

    2016-02-01

    Cardiac resynchronization therapy indications and management are well described in adults. Echocardiography (ECHO) has been used to optimize mechanical synchrony in these patients; however, there are issues with reproducibility and time intensity. Pediatric patients add challenges, with diverse substrates and limited capacity for cooperation. Electrocardiographic (ECG) methods to assess electrical synchrony are expeditious but have not been extensively studied in children. We sought to compare ECHO and ECG CRT optimization in children. Prospective, pediatric, single-center cross-over trial comparing ECHO and ECG optimization with CRT. Patients were assigned to undergo either ECHO or ECG optimization, followed for 6 months, and crossed-over to the other assignment for another 6 months. ECHO pulsed-wave tissue Doppler and 12-lead ECG were obtained for 5 VV delays. ECG optimization was defined as the shortest QRSD and ECHO optimization as the lowest dyssynchrony index. ECHOs/ECGs were interpreted by readers blinded to optimization technique. After each 6 month period, these data were collected: ejection fraction, velocimetry-derived cardiac index, quality of life, ECHO-derived stroke distance, M-mode dyssynchrony, study cost, and time. Outcomes for each optimization method were compared. From June 2012 to December 2013, 19 patients enrolled. Mean age was 9.1 ± 4.3 years; 14 (74%) had structural heart disease. The mean time for optimization was shorter using ECG than ECHO (9 ± 1 min vs. 68 ± 13 min, P cost for charges was $4,400 ± 700 less for ECG. No other outcome differed between groups. ECHO optimization of synchrony was not superior to ECG optimization in this pilot study. ECG optimization required less time and cost than ECHO optimization. © 2015 Wiley Periodicals, Inc.

  11. [An Algorithm to Eliminate Power Frequency Interference in ECG Using Template].

    Science.gov (United States)

    Shi, Guohua; Li, Jiang; Xu, Yan; Feng, Liang

    2017-01-01

    Researching an algorithm to eliminate power frequency interference in ECG. The algorithm first creates power frequency interference template, then, subtracts the template from the original ECG signals, final y, the algorithm gets the ECG signals without interference. Experiment shows the algorithm can eliminate interference effectively and has none side effect to normal signal. It’s efficient and suitable for practice.

  12. ECG biometric identification: A compression based approach.

    Science.gov (United States)

    Bras, Susana; Pinho, Armando J

    2015-08-01

    Using the electrocardiogram signal (ECG) to identify and/or authenticate persons are problems still lacking satisfactory solutions. Yet, ECG possesses characteristics that are unique or difficult to get from other signals used in biometrics: (1) it requires contact and liveliness for acquisition (2) it changes under stress, rendering it potentially useless if acquired under threatening. Our main objective is to present an innovative and robust solution to the above-mentioned problem. To successfully conduct this goal, we rely on information-theoretic data models for data compression and on similarity metrics related to the approximation of the Kolmogorov complexity. The proposed measure allows the comparison of two (or more) ECG segments, without having to follow traditional approaches that require heartbeat segmentation (described as highly influenced by external or internal interferences). As a first approach, the method was able to cluster the data in three groups: identical record, same participant, different participant, by the stratification of the proposed measure with values near 0 for the same participant and closer to 1 for different participants. A leave-one-out strategy was implemented in order to identify the participant in the database based on his/her ECG. A 1NN classifier was implemented, using as distance measure the method proposed in this work. The classifier was able to identify correctly almost all participants, with an accuracy of 99% in the database used.

  13. Real-Time ECG Simulation for Hybrid Mock Circulatory Loops.

    Science.gov (United States)

    Korn, Leonie; Rüschen, Daniel; Zander, Niklas; Leonhardt, Steffen; Walter, Marian

    2018-02-01

    Classically, mock circulatory loops only simulate mechanical properties of the circulation. To connect the hydraulic world with electrophysiology, we present a real-time electrical activity model of the heart and show how to integrate this model into a real-time mock loop simulation. The model incorporates a predefined conduction pathway and a simplified volume conductor to solve the bidomain equations and the forward problem of electrocardiography, resulting in a physiological simulation of the electrocardiogram (ECG) at arbitrary electrode positions. A complete physiological simulation of the heart's excitation would be too CPU intensive. Thus, in our model, complexity was reduced to allow real-time simulation of ECG-triggered medical systems in vitro; this decreases time and cost in the development process. Conversely, the presented model can still be adapted to various pathologies by locally changing the properties of the heart's conduction pathway. To simulate the ECG, the heart is divided into suitable areas, which are innervated by the hierarchically structured conduction system. To distinguish different cardiac regions, a segmentation of the heart was performed. In these regions, Prim's algorithm was applied to identify the directed minimal spanning trees for conduction orientation. Each node of the tree was assigned to a cardiac action potential generated by its hybrid automaton to represent the heart's conduction system by the spatial distribution of action potentials. To generate the ECG output, the bidomain equations were implemented and a simple model of the volume conductor of the body was used to solve the forward problem of electrocardiography. As a result, the model simulates potentials at arbitrary electrode positions in real-time. To verify the developed real-time ECG model, measurements were made within a hybrid mock circulatory loop, including a simple ECG-triggered ventricular assist device control. The model's potential value is to simulate

  14. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Directory of Open Access Journals (Sweden)

    G. Carrault

    2008-09-01

    Full Text Available Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA. The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  15. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Science.gov (United States)

    Kachenoura, A.; Porée, F.; Hernández, A. I.; Carrault, G.

    2008-12-01

    Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs) are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG) from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA). The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  16. ECG-cryptography and authentication in body area networks.

    Science.gov (United States)

    Zhang, Zhaoyang; Wang, Honggang; Vasilakos, Athanasios V; Fang, Hua

    2012-11-01

    Wireless body area networks (BANs) have drawn much attention from research community and industry in recent years. Multimedia healthcare services provided by BANs can be available to anyone, anywhere, and anytime seamlessly. A critical issue in BANs is how to preserve the integrity and privacy of a person's medical data over wireless environments in a resource efficient manner. This paper presents a novel key agreement scheme that allows neighboring nodes in BANs to share a common key generated by electrocardiogram (ECG) signals. The improved Jules Sudan (IJS) algorithm is proposed to set up the key agreement for the message authentication. The proposed ECG-IJS key agreement can secure data communications over BANs in a plug-n-play manner without any key distribution overheads. Both the simulation and experimental results are presented, which demonstrate that the proposed ECG-IJS scheme can achieve better security performance in terms of serval performance metrics such as false acceptance rate (FAR) and false rejection rate (FRR) than other existing approaches. In addition, the power consumption analysis also shows that the proposed ECG-IJS scheme can achieve energy efficiency for BANs.

  17. Development of a portable Linux-based ECG measurement and monitoring system.

    Science.gov (United States)

    Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng

    2011-08-01

    This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.

  18. Stomatal cell wall composition: distinctive structural patterns associated with different phylogenetic groups.

    Science.gov (United States)

    Shtein, Ilana; Shelef, Yaniv; Marom, Ziv; Zelinger, Einat; Schwartz, Amnon; Popper, Zoë A; Bar-On, Benny; Harpaz-Saad, Smadar

    2017-04-01

    Stomatal morphology and function have remained largely conserved throughout ∼400 million years of plant evolution. However, plant cell wall composition has evolved and changed. Here stomatal cell wall composition was investigated in different vascular plant groups in attempt to understand their possible effect on stomatal function. A renewed look at stomatal cell walls was attempted utilizing digitalized polar microscopy, confocal microscopy, histology and a numerical finite-elements simulation. The six species of vascular plants chosen for this study cover a broad structural, ecophysiological and evolutionary spectrum: ferns ( Asplenium nidus and Platycerium bifurcatum ) and angiosperms ( Arabidopsis thaliana and Commelina erecta ) with kidney-shaped stomata, and grasses (angiosperms, family Poaceae) with dumbbell-shaped stomata ( Sorghum bicolor and Triticum aestivum ). Three distinct patterns of cellulose crystallinity in stomatal cell walls were observed: Type I (kidney-shaped stomata, ferns), Type II (kidney-shaped stomata, angiosperms) and Type III (dumbbell-shaped stomata, grasses). The different stomatal cell wall attributes investigated (cellulose crystallinity, pectins, lignin, phenolics) exhibited taxon-specific patterns, with reciprocal substitution of structural elements in the end-walls of kidney-shaped stomata. According to a numerical bio-mechanical model, the end walls of kidney-shaped stomata develop the highest stresses during opening. The data presented demonstrate for the first time the existence of distinct spatial patterns of varying cellulose crystallinity in guard cell walls. It is also highly intriguing that in angiosperms crystalline cellulose appears to have replaced lignin that occurs in the stomatal end-walls of ferns serving a similar wall strengthening function. Such taxon-specific spatial patterns of cell wall components could imply different biomechanical functions, which in turn could be a consequence of differences in

  19. Integrated processing of ECG's in a hospital information system

    NARCIS (Netherlands)

    Helder, J.C.; Schram, P.H.; Verwey, H.; Meijler, F.L.; Robles de Medina, E.O.

    The ECG handling in the University Hospital of Utrecht is composed by a system consisting of acquisition and storage of ECG signals, computer analysis, data management, and storage of readings in a patient data base. The last two modules are part of a Hospital Information System (HIS). The modular

  20. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    International Nuclear Information System (INIS)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor

    2010-01-01

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 ± 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI ( 2 : 100 kV, >25 kg/m 2 : 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 ± 11.1 bpm, variability 1.0 ± 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 ± 16.6 bpm, variability 17.9 ± 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 ± 0.3 and 3.0 ± 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  1. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  2. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  3. Smartphone ECG for evaluation of STEMI: results of the ST LEUIS Pilot Study.

    Science.gov (United States)

    Muhlestein, Joseph Boone; Le, Viet; Albert, David; Moreno, Fidela Ll; Anderson, Jeffrey L; Yanowitz, Frank; Vranian, Robert B; Barsness, Gregory W; Bethea, Charles F; Severance, Harry W; Ramo, Barry; Pierce, John; Barbagelata, Alejandro; Muhlestein, Joseph Brent

    2015-01-01

    12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. ECG denoising with adaptive bionic wavelet transform.

    Science.gov (United States)

    Sayadi, Omid; Shamsollahi, Mohammad Bagher

    2006-01-01

    In this paper a new ECG denoising scheme is proposed using a novel adaptive wavelet transform, named bionic wavelet transform (BWT), which had been first developed based on a model of the active auditory system. There has been some outstanding features with the BWT such as nonlinearity, high sensitivity and frequency selectivity, concentrated energy distribution and its ability to reconstruct signal via inverse transform but the most distinguishing characteristic of BWT is that its resolution in the time-frequency domain can be adaptively adjusted not only by the signal frequency but also by the signal instantaneous amplitude and its first-order differential. Besides by optimizing the BWT parameters parallel to modifying a new threshold value, one can handle ECG denoising with results comparing to those of wavelet transform (WT). Preliminary tests of BWT application to ECG denoising were constructed on the signals of MIT-BIH database which showed high performance of noise reduction.

  5. Behavioral states may be associated with distinct spatial patterns in electrocorticogram.

    Science.gov (United States)

    Panagiotides, Heracles; Freeman, Walter J; Holmes, Mark D; Pantazis, Dimitrios

    2011-03-01

    To determine if behavioral states are associated with unique spatial electrocorticographic (ECoG) patterns, we obtained recordings with a microgrid electrode array applied to the cortical surface of a human subject. The array was constructed with the intent of extracting maximal spatial information by optimizing interelectrode distances. A 34-year-old patient with intractable epilepsy underwent intracranial ECoG monitoring after standard methods failed to reveal localization of seizures. During the 8-day period of invasive recording, in addition to standard clinical electrodes a square 1 × 1 cm microgrid array with 64 electrodes (1.25 mm separation) was placed on the right inferior temporal gyrus. Careful review of video recordings identified four extended naturalistic behaviors: reading, conversing on the telephone, looking at photographs, and face-to-face interactions. ECoG activity recorded with the microgrid that corresponded to these behaviors was collected and ECoG spatial patterns were analyzed. During periods of ECoG selected for analysis, no electrographic seizures or epileptiform patterns were present. Moments of maximal spatial variance are shown to cluster by behavior. Comparisons between conditions using a permutation test reveal significantly different spatial patterns for each behavior. We conclude that ECoG recordings obtained on the cortical surface with optimal high spatial frequency resolution reveal distinct local spatial patterns that reflect different behavioral states, and we predict that similar patterns will be found in many if not most cortical areas on which a microgrid is placed.

  6. Statistical performance evaluation of ECG transmission using wireless networks.

    Science.gov (United States)

    Shakhatreh, Walid; Gharaibeh, Khaled; Al-Zaben, Awad

    2013-07-01

    This paper presents simulation of the transmission of biomedical signals (using ECG signal as an example) over wireless networks. Investigation of the effect of channel impairments including SNR, pathloss exponent, path delay and network impairments such as packet loss probability; on the diagnosability of the received ECG signal are presented. The ECG signal is transmitted through a wireless network system composed of two communication protocols; an 802.15.4- ZigBee protocol and an 802.11b protocol. The performance of the transmission is evaluated using higher order statistics parameters such as kurtosis and Negative Entropy in addition to the common techniques such as the PRD, RMS and Cross Correlation.

  7. AUDITORY NUCLEI: DISTINCTIVE RESPONSE PATTERNS TO WHITE NOISE AND TONES IN UNANESTHETIZED CATS.

    Science.gov (United States)

    GALIN, D

    1964-10-09

    Electrical responses to "white" noise and tonal stimuli were recorded from unanesthetized cats with permanently implanted bipolar electrodes. The cochlear nucleus, inferior colliculus, and medial geniculate each showed distinctive patterns of evoked activity. White noise and tones produced qualitatively different types of response. A decrease in activity characterized the response of the inferior colliculus to tonal stimuli.

  8. Mobile application development for Tele-ECG

    International Nuclear Information System (INIS)

    Srivastava, Shikha; Bharade, Sandeep; Sinha, Vineet; Sarade, Bhagyashree; Jindal, G.D.; Ananthakrishnan, T.S.; Pithawa, C.K.

    2010-01-01

    Mobile computing has caught the attention of research community for quite some time. The constant improvement of hardware and software related to mobile computing (e.g. better computing power, larger wireless network bandwidth) clearly enhance capabilities of mobile devices. The acceptance of mobile technology by the population at large would suggest that this could be the basis of a system for the communication of medical data from patients to remote physician and vice versa. This paper presents a mobile solution, which makes use of a Tele-ECG unit with a mobile phone to collect, store and forward ECG data to a cardiologist for diagnosis and recommendation. (author)

  9. Decomposition of ECG by linear filtering.

    Science.gov (United States)

    Murthy, I S; Niranjan, U C

    1992-01-01

    A simple method is developed for the delineation of a given electrocardiogram (ECG) signal into its component waves. The properties of discrete cosine transform (DCT) are exploited for the purpose. The transformed signal is convolved with appropriate filters and the component waves are obtained by computing the inverse transform (IDCT) of the filtered signals. The filters are derived from the time signal itself. Analysis of continuous strips of ECG signals with various arrhythmias showed that the performance of the method is satisfactory both qualitatively and quantitatively. The small amplitude P wave usually had a high percentage rms difference (PRD) compared to the other large component waves.

  10. [Experience in the use of equipment for ECG system analysis in municipal polyclinics].

    Science.gov (United States)

    Bondarenko, A A

    2006-01-01

    Two electrocardiographs, an analog-digital electrocardiograph with preliminary analog filtering of signal and a smart cardiograph implemented as a PC-compatible device without preliminary analog filtering, are considered. Advantages and disadvantages of ECG systems based on artificial intelligence are discussed. ECG interpretation modes provided by the two electrocardiographs are considered. The reliability of automatic ECG interpretation is assessed. Problems of rational use of automated ECG processing systems are discussed.

  11. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    Science.gov (United States)

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  12. An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare.

    Science.gov (United States)

    Yang, Zhe; Zhou, Qihao; Lei, Lei; Zheng, Kan; Xiang, Wei

    2016-12-01

    Public healthcare has been paid an increasing attention given the exponential growth human population and medical expenses. It is well known that an effective health monitoring system can detect abnormalities of health conditions in time and make diagnoses according to the gleaned data. As a vital approach to diagnose heart diseases, ECG monitoring is widely studied and applied. However, nearly all existing portable ECG monitoring systems cannot work without a mobile application, which is responsible for data collection and display. In this paper, we propose a new method for ECG monitoring based on Internet-of-Things (IoT) techniques. ECG data are gathered using a wearable monitoring node and are transmitted directly to the IoT cloud using Wi-Fi. Both the HTTP and MQTT protocols are employed in the IoT cloud in order to provide visual and timely ECG data to users. Nearly all smart terminals with a web browser can acquire ECG data conveniently, which has greatly alleviated the cross-platform issue. Experiments are carried out on healthy volunteers in order to verify the reliability of the entire system. Experimental results reveal that the proposed system is reliable in collecting and displaying real-time ECG data, which can aid in the primary diagnosis of certain heart diseases.

  13. Improving Remote Health Monitoring: A Low-Complexity ECG Compression Approach.

    Science.gov (United States)

    Elgendi, Mohamed; Al-Ali, Abdulla; Mohamed, Amr; Ward, Rabab

    2018-01-16

    Recent advances in mobile technology have created a shift towards using battery-driven devices in remote monitoring settings and smart homes. Clinicians are carrying out diagnostic and screening procedures based on the electrocardiogram (ECG) signals collected remotely for outpatients who need continuous monitoring. High-speed transmission and analysis of large recorded ECG signals are essential, especially with the increased use of battery-powered devices. Exploring low-power alternative compression methodologies that have high efficiency and that enable ECG signal collection, transmission, and analysis in a smart home or remote location is required. Compression algorithms based on adaptive linear predictors and decimation by a factor B / K are evaluated based on compression ratio (CR), percentage root-mean-square difference (PRD), and heartbeat detection accuracy of the reconstructed ECG signal. With two databases (153 subjects), the new algorithm demonstrates the highest compression performance ( CR = 6 and PRD = 1.88 ) and overall detection accuracy (99.90% sensitivity, 99.56% positive predictivity) over both databases. The proposed algorithm presents an advantage for the real-time transmission of ECG signals using a faster and more efficient method, which meets the growing demand for more efficient remote health monitoring.

  14. Improving Remote Health Monitoring: A Low-Complexity ECG Compression Approach

    Directory of Open Access Journals (Sweden)

    Mohamed Elgendi

    2018-01-01

    Full Text Available Recent advances in mobile technology have created a shift towards using battery-driven devices in remote monitoring settings and smart homes. Clinicians are carrying out diagnostic and screening procedures based on the electrocardiogram (ECG signals collected remotely for outpatients who need continuous monitoring. High-speed transmission and analysis of large recorded ECG signals are essential, especially with the increased use of battery-powered devices. Exploring low-power alternative compression methodologies that have high efficiency and that enable ECG signal collection, transmission, and analysis in a smart home or remote location is required. Compression algorithms based on adaptive linear predictors and decimation by a factor B / K are evaluated based on compression ratio (CR, percentage root-mean-square difference (PRD, and heartbeat detection accuracy of the reconstructed ECG signal. With two databases (153 subjects, the new algorithm demonstrates the highest compression performance ( CR = 6 and PRD = 1.88 and overall detection accuracy (99.90% sensitivity, 99.56% positive predictivity over both databases. The proposed algorithm presents an advantage for the real-time transmission of ECG signals using a faster and more efficient method, which meets the growing demand for more efficient remote health monitoring.

  15. An Adaptive and Time-Efficient ECG R-Peak Detection Algorithm.

    Science.gov (United States)

    Qin, Qin; Li, Jianqing; Yue, Yinggao; Liu, Chengyu

    2017-01-01

    R-peak detection is crucial in electrocardiogram (ECG) signal analysis. This study proposed an adaptive and time-efficient R-peak detection algorithm for ECG processing. First, wavelet multiresolution analysis was applied to enhance the ECG signal representation. Then, ECG was mirrored to convert large negative R-peaks to positive ones. After that, local maximums were calculated by the first-order forward differential approach and were truncated by the amplitude and time interval thresholds to locate the R-peaks. The algorithm performances, including detection accuracy and time consumption, were tested on the MIT-BIH arrhythmia database and the QT database. Experimental results showed that the proposed algorithm achieved mean sensitivity of 99.39%, positive predictivity of 99.49%, and accuracy of 98.89% on the MIT-BIH arrhythmia database and 99.83%, 99.90%, and 99.73%, respectively, on the QT database. By processing one ECG record, the mean time consumptions were 0.872 s and 0.763 s for the MIT-BIH arrhythmia database and QT database, respectively, yielding 30.6% and 32.9% of time reduction compared to the traditional Pan-Tompkins method.

  16. Accurate Interpretation of the 12-Lead ECG Electrode Placement: A Systematic Review

    Science.gov (United States)

    Khunti, Kirti

    2014-01-01

    Background: Coronary heart disease (CHD) patients require monitoring through ECGs; the 12-lead electrocardiogram (ECG) is considered to be the non-invasive gold standard. Examples of incorrect treatment because of inaccurate or poor ECG monitoring techniques have been reported in the literature. The findings that only 50% of nurses and less than…

  17. Alterations of the ECG after frationated radiotherapy of the mediastine

    International Nuclear Information System (INIS)

    Alheit, C.; Alheit, H.D.; Herrmann, T.

    1986-01-01

    In 72 patients with irradiation of the mediastine the ECGs were examined before, immediately after, and 3-6 months after termination of radiotherapy. In comparison with starting findings 41.7% ECG alterations were found at the end of irradiation and 40.1% in control examinations. Mainly it was the question of alterations in ST-lines, in type of position, in P-waves, and an increase of the heart rate. However, in result of uni- and multivariant variance analyses it could be shown, that extracardiac factors and general reactions of the irradiated organism resulted in ECG alterations too. Considering the correlation of ECG alterations to the heart dose however, a direct influence of the capillary system of the heart has also to be discussed and an adequate after-care of patients with irradiation of the mediastine must be recommended. (author)

  18. Can Functional Cardiac Age be Predicted from ECG in a Normal Healthy Population

    Science.gov (United States)

    Schlegel, Todd; Starc, Vito; Leban, Manja; Sinigoj, Petra; Vrhovec, Milos

    2011-01-01

    In a normal healthy population, we desired to determine the most age-dependent conventional and advanced ECG parameters. We hypothesized that changes in several ECG parameters might correlate with age and together reliably characterize the functional age of the heart. Methods: An initial study population of 313 apparently healthy subjects was ultimately reduced to 148 subjects (74 men, 84 women, in the range from 10 to 75 years of age) after exclusion criteria. In all subjects, ECG recordings (resting 5-minute 12-lead high frequency ECG) were evaluated via custom software programs to calculate up to 85 different conventional and advanced ECG parameters including beat-to-beat QT and RR variability, waveform complexity, and signal-averaged, high-frequency and spatial/spatiotemporal ECG parameters. The prediction of functional age was evaluated by multiple linear regression analysis using the best 5 univariate predictors. Results: Ignoring what were ultimately small differences between males and females, the functional age was found to be predicted (R2= 0.69, P ECGs, functional cardiac age can be estimated by multiple linear regression analysis of mostly advanced ECG results. Because some parameters in the regression formula, such as QTcorr, high frequency QRS amplitude and P-wave width also change with disease in the same direction as with increased age, increased functional age of the heart may reflect subtle age-related pathologies in cardiac electrical function that are usually hidden on conventional ECG.

  19. A Mobile Device System for Early Warning of ECG Anomalies

    Directory of Open Access Journals (Sweden)

    Adam Szczepański

    2014-06-01

    Full Text Available With the rapid increase in computational power of mobile devices the amount of ambient intelligence-based smart environment systems has increased greatly in recent years. A proposition of such a solution is described in this paper, namely real time monitoring of an electrocardiogram (ECG signal during everyday activities for identification of life threatening situations. The paper, being both research and review, describes previous work of the authors, current state of the art in the context of the authors’ work and the proposed aforementioned system. Although parts of the solution were described in earlier publications of the authors, the whole concept is presented completely for the first time along with the prototype implementation on mobile device—a Windows 8 tablet with Modern UI. The system has three main purposes. The first goal is the detection of sudden rapid cardiac malfunctions and informing the people in the patient’s surroundings, family and friends and the nearest emergency station about the deteriorating health of the monitored person. The second goal is a monitoring of ECG signals under non-clinical conditions to detect anomalies that are typically not found during diagnostic tests. The third goal is to register and analyze repeatable, long-term disturbances in the regular signal and finding their patterns.

  20. Performance of human body communication-based wearable ECG with capacitive coupling electrodes.

    Science.gov (United States)

    Sakuma, Jun; Anzai, Daisuke; Wang, Jianqing

    2016-09-01

    Wearable electrocardiogram (ECG) is attracting much attention in daily healthcare applications, and human body communication (HBC) technology provides an evident advantage in making the sensing electrodes of ECG also working for transmission through the human body. In view of actual usage in daily life, however, non-contact electrodes to the human body are desirable. In this Letter, the authors discussed the ECG circuit structure in the HBC-based wearable ECG for removing the common mode noise when employing non-contact capacitive coupling electrodes. Through the comparison of experimental results, they have shown that the authors' proposed circuit structure with the third electrode directly connected to signal ground can provide an effect on common mode noise reduction similar to the usual drive-right-leg circuit, and a sufficiently good acquisition performance of ECG signals.

  1. Evaluation of a web-based ECG-interpretation programme for undergraduate medical students.

    Science.gov (United States)

    Nilsson, Mikael; Bolinder, Gunilla; Held, Claes; Johansson, Bo-Lennart; Fors, Uno; Ostergren, Jan

    2008-04-23

    Most clinicians and teachers agree that knowledge about ECG is of importance in the medical curriculum. Students at Karolinska Institute have asked for more training in ECG-interpretation during their undergraduate studies. Clinical tutors, however, have difficulties in meeting these demands due to shortage of time. Thus, alternative ways to learn and practice ECG-interpretation are needed. Education offered via the Internet is readily available, geographically independent and flexible. Furthermore, the quality of education may increase and become more effective through a superior educational approach, improved visualization and interactivity. A Web-based comprehensive ECG-interpretation programme has been evaluated. Medical students from the sixth semester were given an optional opportunity to access the programme from the start of their course. Usage logs and an initial evaluation survey were obtained from each student. A diagnostic test was performed in order to assess the effect on skills in ECG interpretation. Students from the corresponding course, at another teaching hospital and without access to the ECG-programme but with conventional teaching of ECG served as a control group. 20 of the 32 students in the intervention group had tested the programme after 2 months. On a five-graded scale (1- bad to 5 - very good) they ranked the utility of a web-based programme for this purpose as 4.1 and the quality of the programme software as 3.9. At the diagnostic test (maximal points 16) by the end of the 5-month course at the 6th semester the mean result for the students in the intervention group was 9.7 compared with 8.1 for the control group (p = 0.03). Students ranked the Web-based ECG-interpretation programme as a useful instrument to learn ECG. Furthermore, Internet-delivered education may be more effective than traditional teaching methods due to greater immediacy, improved visualisation and interactivity.

  2. Performance evaluation of carbon black based electrodes for underwater ECG monitoring.

    Science.gov (United States)

    Reyes, Bersain A; Posada-Quintero, Hugo F; Bales, Justin R; Chon, Ki H

    2014-01-01

    Underwater electrocardiogram (ECG) monitoring currently uses Ag/AgCl electrodes and requires sealing of the electrodes to avoid water intrusion, but this procedure is time consuming and often results in severe irritations or even tearing of the skin. To alleviate these problems, our research team developed hydrophobic electrodes comprised of a mixture of carbon black powder (CB) and polydimethylsiloxane (PDMS) that provide all morphological waveforms without distortion of an ECG signal for dry and water-immersed conditions. Performance comparison of CB/PDMS electrodes to adhesive Ag/AgCl hydrogel electrodes was carried out in three different scenarios which included recordings from a dry surface, water immersion, and post-water immersion conditions. CB/PDMS electrodes were able to acquire ECG signals highly correlated with those from adhesive Ag/AgCl electrodes during all conditions. Statistical reduction in ECG amplitude (pelectrodes when compared to Ag/AgCl electrodes sealed with their waterproof adhesive tape. Besides this reduction readability of the recordings was not obscured and all morphological waveforms of the ECG signal were discernible. The advantages of our CB/PDMS electrodes are that they are reusable, can be fabricated economically, and most importantly, high-fidelity underwater ECG signals can be acquired without relying on the heavy use of waterproof sealing.

  3. Cancelable ECG biometrics using GLRT and performance improvement using guided filter with irreversible guide signal.

    Science.gov (United States)

    Kim, Hanvit; Minh Phuong Nguyen; Se Young Chun

    2017-07-01

    Biometrics such as ECG provides a convenient and powerful security tool to verify or identify an individual. However, one important drawback of biometrics is that it is irrevocable. In other words, biometrics cannot be re-used practically once it is compromised. Cancelable biometrics has been investigated to overcome this drawback. In this paper, we propose a cancelable ECG biometrics by deriving a generalized likelihood ratio test (GLRT) detector from a composite hypothesis testing in randomly projected domain. Since it is common to observe performance degradation for cancelable biometrics, we also propose a guided filtering (GF) with irreversible guide signal that is a non-invertibly transformed signal of ECG authentication template. We evaluated our proposed method using ECG-ID database with 89 subjects. Conventional Euclidean detector with original ECG template yielded 93.9% PD1 (detection probability at 1% FAR) while Euclidean detector with 10% compressed ECG (1/10 of the original data size) yielded 90.8% PD1. Our proposed GLRT detector with 10% compressed ECG yielded 91.4%, which is better than Euclidean with the same compressed ECG. GF with our proposed irreversible ECG template further improved the performance of our GLRT with 10% compressed ECG up to 94.3%, which is higher than Euclidean detector with original ECG. Lastly, we showed that our proposed cancelable ECG biometrics practically met cancelable biometrics criteria such as efficiency, re-usability, diversity and non-invertibility.

  4. SUPPRESSION OF POWERLINE INTERFERENCE IN ECG USING ADAPTIVE DIGITAL FILTER BY

    OpenAIRE

    Mbachu C.B; Onoh G. N; Idigo V.E; Oguejiofor O.S

    2011-01-01

    Artifacts in electrocardiogram (ECG) records are caused by various factors, such as powerline interference, electroencephalogram (EEG), electromyogram (EMG) and baseline wander. These noise sources increase the difficulty in analyzing the ECG and to obtaining clinical information. For that reason, it is necessary to designspecific filters to decrease such artifacts in ECG records. In this paper, FIR adaptive filter based on a least mean square (LMS) algorithm for eliminating 50Hz powerline in...

  5. A new feature detection mechanism and its application in secured ECG transmission with noise masking.

    Science.gov (United States)

    Sufi, Fahim; Khalil, Ibrahim

    2009-04-01

    With cardiovascular disease as the number one killer of modern era, Electrocardiogram (ECG) is collected, stored and transmitted in greater frequency than ever before. However, in reality, ECG is rarely transmitted and stored in a secured manner. Recent research shows that eavesdropper can reveal the identity and cardiovascular condition from an intercepted ECG. Therefore, ECG data must be anonymized before transmission over the network and also stored as such in medical repositories. To achieve this, first of all, this paper presents a new ECG feature detection mechanism, which was compared against existing cross correlation (CC) based template matching algorithms. Two types of CC methods were used for comparison. Compared to the CC based approaches, which had 40% and 53% misclassification rates, the proposed detection algorithm did not perform any single misclassification. Secondly, a new ECG obfuscation method was designed and implemented on 15 subjects using added noises corresponding to each of the ECG features. This obfuscated ECG can be freely distributed over the internet without the necessity of encryption, since the original features needed to identify personal information of the patient remain concealed. Only authorized personnel possessing a secret key will be able to reconstruct the original ECG from the obfuscated ECG. Distribution of the would appear as regular ECG without encryption. Therefore, traditional decryption techniques including powerful brute force attack are useless against this obfuscation.

  6. ECG Signal Processing, Classification and Interpretation A Comprehensive Framework of Computational Intelligence

    CERN Document Server

    Pedrycz, Witold

    2012-01-01

    Electrocardiogram (ECG) signals are among the most important sources of diagnostic information in healthcare so improvements in their analysis may also have telling consequences. Both the underlying signal technology and a burgeoning variety of algorithms and systems developments have proved successful targets for recent rapid advances in research. ECG Signal Processing, Classification and Interpretation shows how the various paradigms of Computational Intelligence, employed either singly or in combination, can produce an effective structure for obtaining often vital information from ECG signals. Neural networks do well at capturing the nonlinear nature of the signals, information granules realized as fuzzy sets help to confer interpretability on the data and evolutionary optimization may be critical in supporting the structural development of ECG classifiers and models of ECG signals. The contributors address concepts, methodology, algorithms, and case studies and applications exploiting the paradigm of Comp...

  7. Performance Analysis of Ten Common QRS Detectors on Different ECG Application Cases

    Directory of Open Access Journals (Sweden)

    Feifei Liu

    2018-01-01

    Full Text Available A systematical evaluation work was performed on ten widely used and high-efficient QRS detection algorithms in this study, aiming at verifying their performances and usefulness in different application situations. Four experiments were carried on six internationally recognized databases. Firstly, in the test of high-quality ECG database versus low-quality ECG database, for high signal quality database, all ten QRS detection algorithms had very high detection accuracy (F1 >99%, whereas the F1 results decrease significantly for the poor signal-quality ECG signals (all 95% except RS slope algorithm with 94.24% on normal ECG database and 94.44% on arrhythmia database. Thirdly, for the paced rhythm ECG database, all ten algorithms were immune to the paced beats (>94% except the RS slope method, which only output a low F1 result of 78.99%. At last, the detection accuracies had obvious decreases when dealing with the dynamic telehealth ECG signals (all <80% except OKB algorithm with 80.43%. Furthermore, the time costs from analyzing a 10 s ECG segment were given as the quantitative index of the computational complexity. All ten algorithms had high numerical efficiency (all <4 ms except RS slope (94.07 ms and sixth power algorithms (8.25 ms. And OKB algorithm had the highest numerical efficiency (1.54 ms.

  8. Step-and-shoot prospectively ECG-gated vs. retrospectively ECG-gated with tube current modulation coronary CT angiography using 128-slice MDCT patients with chest pain: diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Kim, Jeong Su; Choo, Ki Seok; Jeong, Dong Wook

    2011-01-01

    Background With increasing awareness for radiation exposure, the study of diagnostic accuracy of coronary CT angiography (CCTA) with low radiation dose techniques is mandatory to both radiologist and clinician. Purpose To compare diagnostic performance and effective radiation dose between step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with tube current modulation (TCM) CCTA using 128-slice multidetector computed tomography (MDCT). Material and Methods We retrospectively evaluated 60 patients who underwent CCTA with either of two different low-dose techniques using 128-slice MDCT (23 patients for step-and shoot-prospectively ECG-gated and 37 patients for retrospectively ECG-gated with TCM CCTA) followed by conventional coronary angiography. All coronary arteries and all segments thereof, except anatomical variants or small size (< 1.5 mm) ones, were included in analysis. Results In per-segment analysis, sensitivity, specificity, positive predictive value, and negative predictive value were 91/96%, 95/94%, 75/73%, and 98/99% for step-and-shoot prospectively ECG-gated and retrospectively ECG gated with TCM CCTA, respectively, relative to conventional coronary angiography. Effective radiation dose were 1.75 ± 0.83 mSv, 4.91 ± 1.71 mSv in the step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with TCM CCTA groups, respectively. Conclusion The two low-radiation dose CCTA techniques using 128-slice MDCT yields comparable diagnostic performance for coronary artery disease in symptomatic patients with low heart rates

  9. A comprehensive survey of wearable and wireless ECG monitoring systems for older adults.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid; Connolly, Martin J

    2013-05-01

    Wearable health monitoring is an emerging technology for continuous monitoring of vital signs including the electrocardiogram (ECG). This signal is widely adopted to diagnose and assess major health risks and chronic cardiac diseases. This paper focuses on reviewing wearable ECG monitoring systems in the form of wireless, mobile and remote technologies related to older adults. Furthermore, the efficiency, user acceptability, strategies and recommendations on improving current ECG monitoring systems with an overview of the design and modelling are presented. In this paper, over 120 ECG monitoring systems were reviewed and classified into smart wearable, wireless, mobile ECG monitoring systems with related signal processing algorithms. The results of the review suggest that most research in wearable ECG monitoring systems focus on the older adults and this technology has been adopted in aged care facilitates. Moreover, it is shown that how mobile telemedicine systems have evolved and how advances in wearable wireless textile-based systems could ensure better quality of healthcare delivery. The main drawbacks of deployed ECG monitoring systems including imposed limitations on patients, short battery life, lack of user acceptability and medical professional's feedback, and lack of security and privacy of essential data have been also discussed.

  10. Fetal ECG extraction using independent component analysis by Jade approach

    Science.gov (United States)

    Giraldo-Guzmán, Jader; Contreras-Ortiz, Sonia H.; Lasprilla, Gloria Isabel Bautista; Kotas, Marian

    2017-11-01

    Fetal ECG monitoring is a useful method to assess the fetus health and detect abnormal conditions. In this paper we propose an approach to extract fetal ECG from abdomen and chest signals using independent component analysis based on the joint approximate diagonalization of eigenmatrices approach. The JADE approach avoids redundancy, what reduces matrix dimension and computational costs. Signals were filtered with a high pass filter to eliminate low frequency noise. Several levels of decomposition were tested until the fetal ECG was recognized in one of the separated sources output. The proposed method shows fast and good performance.

  11. The role of the ECG in diagnosis, risk estimation, and catheterization laboratory activation in patients with acute coronary syndromes: a consensus document.

    Science.gov (United States)

    Birnbaum, Yochai; Nikus, Kjell; Kligfield, Paul; Fiol, Miguel; Barrabés, Jose Antonio; Sionis, Alessandro; Pahlm, Olle; Niebla, J Garcia; de Luna, Antonio Bayès

    2014-09-01

    The electrocardiogram (ECG) is the most widely used imaging tool helping in diagnosis and initial management of patients presenting with symptoms compatible with acute coronary syndrome. Acute ischemia affects the configuration of the QRS complexes, the ST segments and the T waves. The ECG should be read along with the clinical assessment of the patient. ST segment elevation (and ST depression in leads V1 -V3 ) in patients with active symptoms usually indicates acute occlusion of an epicardial artery with ongoing transmural ischemia. These patients should be triaged for emergent reperfusion therapy per current guidelines. However, many patients have ST segment elevation secondary to nonischemic causes. ST depression in leads other than V1 -V3 usually are indicative of subendocardial ischemia secondary to subocclusion of the epicardial artery, distal embolization to small arteries or spasm supply/demand mismatch. ST depression may also be secondary to nonischemic etiologies, such as left ventricular hypertrophy, cardiomyopathies, etc. Knowing the clinical scenario, comparison to previous ECG and subsequent ECGs (in cases that there are changes in the quality or severity of symptoms) may add in the diagnosis and interpretation in difficult cases. This review addresses the different ECG patterns, typically seen in patients with active symptoms, after resolution of symptoms and the significance of such changes when seen in asymptomatic patients. © 2014 Wiley Periodicals, Inc.

  12. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring.

    Science.gov (United States)

    Jung, Ha-Chul; Moon, Jin-Hee; Baek, Dong-Hyun; Lee, Jae-Hee; Choi, Yoon-Young; Hong, Joung-Sook; Lee, Sang-Hoon

    2012-05-01

    We fabricated a carbon nanotube (CNT)/ polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

  13. The ECG component of thallium-201 exercise testing significantly alters patient management

    International Nuclear Information System (INIS)

    Deague, J.; Salehi, N.; Grigg, L.; Lichtenstein, M.; Better, N.

    1998-01-01

    Full text: Thallium exercise testing (Tlex) offers superior sensitivity and specificity to exercise electrocardiography (ECG), but the value of the ECG data in Tlex remains poorly studied. While a normal Tlex is associated with an excellent prognosis, patients with a positive Tlex have a higher cardiac event rate. We aimed to see if a negative ECG component of the Tlex (ECGTI) was associated with an improved outcome compared with a positive ECGTI, in those patients with a reversible Tlex defect. We followed 100 consecutive patients retrospectively with a reversible defect on Tlex (50 with negative and 50 with positive (ECGTI) for 12 months. The ECG was reviewed as positive (1 mm ST depression 0.08 seconds after J point or > 2 mm if on digoxin or prior ECG changes), negative, equivocal or uninterpretable. We excluded patients with pharmacological testing, and those with equivocal or uninterpretable ECGs. Over the ensuing 12 months no patients with negative ECGTl was admitted with unstable angina, myocardium infarction or had a cardiac death. It is concluded that in patients with reversible defects on Tlex, a negative ECGTl is associated with a low incidence of cardiac events and a decreased incidence of a cardiac intervention

  14. A novel ECG data compression method based on adaptive Fourier decomposition

    Science.gov (United States)

    Tan, Chunyu; Zhang, Liming

    2017-12-01

    This paper presents a novel electrocardiogram (ECG) compression method based on adaptive Fourier decomposition (AFD). AFD is a newly developed signal decomposition approach, which can decompose a signal with fast convergence, and hence reconstruct ECG signals with high fidelity. Unlike most of the high performance algorithms, our method does not make use of any preprocessing operation before compression. Huffman coding is employed for further compression. Validated with 48 ECG recordings of MIT-BIH arrhythmia database, the proposed method achieves the compression ratio (CR) of 35.53 and the percentage root mean square difference (PRD) of 1.47% on average with N = 8 decomposition times and a robust PRD-CR relationship. The results demonstrate that the proposed method has a good performance compared with the state-of-the-art ECG compressors.

  15. Evaluation of a web-based ECG-interpretation programme for undergraduate medical students

    Directory of Open Access Journals (Sweden)

    Johansson Bo-Lennart

    2008-04-01

    Full Text Available Abstract Background Most clinicians and teachers agree that knowledge about ECG is of importance in the medical curriculum. Students at Karolinska Institutet have asked for more training in ECG-interpretation during their undergraduate studies. Clinical tutors, however, have difficulties in meeting these demands due to shortage of time. Thus, alternative ways to learn and practice ECG-interpretation are needed. Education offered via the Internet is readily available, geographically independent and flexible. Furthermore, the quality of education may increase and become more effective through a superior educational approach, improved visualization and interactivity. Methods A Web-based comprehensive ECG-interpretation programme has been evaluated. Medical students from the sixth semester were given an optional opportunity to access the programme from the start of their course. Usage logs and an initial evaluation survey were obtained from each student. A diagnostic test was performed in order to assess the effect on skills in ECG interpretation. Students from the corresponding course, at another teaching hospital and without access to the ECG-programme but with conventional teaching of ECG served as a control group. Results 20 of the 32 students in the intervention group had tested the programme after 2 months. On a five-graded scale (1- bad to 5 – very good they ranked the utility of a web-based programme for this purpose as 4.1 and the quality of the programme software as 3.9. At the diagnostic test (maximal points 16 by the end of the 5-month course at the 6th semester the mean result for the students in the intervention group was 9.7 compared with 8.1 for the control group (p = 0.03. Conclusion Students ranked the Web-based ECG-interpretation programme as a useful instrument to learn ECG. Furthermore, Internet-delivered education may be more effective than traditional teaching methods due to greater immediacy, improved visualisation and

  16. ECG changes in epilepsy patients

    DEFF Research Database (Denmark)

    Tigaran, S; Rasmussen, V; Dam, M

    1997-01-01

    To investigate the frequency of ECG abnormalities suggestive of myocardial ischaemia in patients with severe drug resistant epilepsy and without any indication of previous cardiac disease, assuming that these changes may be of significance for the group of epileptic patients with sudden unexpected...

  17. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  18. Change detection for synthetic aperture radar images based on pattern and intensity distinctiveness analysis

    Science.gov (United States)

    Wang, Xiao; Gao, Feng; Dong, Junyu; Qi, Qiang

    2018-04-01

    Synthetic aperture radar (SAR) image is independent on atmospheric conditions, and it is the ideal image source for change detection. Existing methods directly analysis all the regions in the speckle noise contaminated difference image. The performance of these methods is easily affected by small noisy regions. In this paper, we proposed a novel change detection framework for saliency-guided change detection based on pattern and intensity distinctiveness analysis. The saliency analysis step can remove small noisy regions, and therefore makes the proposed method more robust to the speckle noise. In the proposed method, the log-ratio operator is first utilized to obtain a difference image (DI). Then, the saliency detection method based on pattern and intensity distinctiveness analysis is utilized to obtain the changed region candidates. Finally, principal component analysis and k-means clustering are employed to analysis pixels in the changed region candidates. Thus, the final change map can be obtained by classifying these pixels into changed or unchanged class. The experiment results on two real SAR images datasets have demonstrated the effectiveness of the proposed method.

  19. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  20. Assessment of the stability of morphological ECG features and their potential for person verification/identification

    Directory of Open Access Journals (Sweden)

    Matveev Mikhail

    2017-01-01

    Full Text Available This study investigates the potential of a set of ECG morphological features for person verification/identification. The measurements are done over 145 pairs of ECG recordings from healthy subjects, acquired 5 years apart (T1, T2 = T1+5 years. Time, amplitude, area and slope descriptors of the QRS-T pattern are analysed in 4 ECG leads, forming quasi-orthogonal lead system (II&III, V1, V5. The correspondence between feature values in T1 and T2 is verified via factor analysis by principal components extraction method; correlation analysis applied over the measurements in T1 and T2; synthesis of regression equations for prediction of features’ values in T2 based on T1 measurements; and cluster analysis for assessment of the correspondence between measured and predicted feature values. Thus, 11 amplitude descriptors of the QRS complex are highlighted as stable, i.e. keeping their strong correlation (≥0.7 within a certain factor, weak correlation (<0.3 with the features from the remaining factors and presenting high correlation in the two measurement periods that is a sign for their person verification/identification potential. The observed coincidence between feature values measured in T2 and predicted via the designed regression models (r=0.93 suggests about the confidence of person identification via the proposed morphological features.

  1. Extraction of the fetal ECG in noninvasive recordings by signal decompositions

    International Nuclear Information System (INIS)

    Christov, I; Simova, I; Abächerli, R

    2014-01-01

    No signal processing technique has been able to reliably deliver an undistorted fetal electrocardiographic (fECG) signal from electrodes placed on the maternal abdomen because of the low signal-to-noise ratio of the fECG recorded from the maternal body surface. As a result, this led to increased rates of Caesarean deliveries of healthy infants. In an attempt to solve the problem, Physionet/Computing in Cardiology announced the 2013 Challenge: noninvasive fetal ECG. We are suggesting a method for cancellation of the maternal ECG consisting of: maternal QRS detection, heart rate dependant P-QRS-T interval selection, location of the fiducial points inside this interval for best matching by cross correlation, superimposition of the intervals, calculation of the mean signal of the P-QRS-T interval, and sequential subtraction of the mean signal from the whole fECG recording. Three signal decomposition methods were further applied in order to enhance the fetal QRSs (fQRS): principal component analysis, root-mean-square and Hotelling’s T-squared. A combined lead of all decompositions was synthesized and fQRS detection was performed on it. The current research differs from the Challenge in that it uses three signal decomposition methods to enhance the fECG. The new results for 97 recordings of test set B are: 305.657 for Event 4: Fetal heart rate (FHR) and 23.062 for Event 5: Fetal RR interval (FRR). (paper)

  2. A Novel Approach to ECG Classification Based upon Two-Layered HMMs in Body Sensor Networks

    Science.gov (United States)

    Liang, Wei; Zhang, Yinlong; Tan, Jindong; Li, Yang

    2014-01-01

    This paper presents a novel approach to ECG signal filtering and classification. Unlike the traditional techniques which aim at collecting and processing the ECG signals with the patient being still, lying in bed in hospitals, our proposed algorithm is intentionally designed for monitoring and classifying the patient's ECG signals in the free-living environment. The patients are equipped with wearable ambulatory devices the whole day, which facilitates the real-time heart attack detection. In ECG preprocessing, an integral-coefficient-band-stop (ICBS) filter is applied, which omits time-consuming floating-point computations. In addition, two-layered Hidden Markov Models (HMMs) are applied to achieve ECG feature extraction and classification. The periodic ECG waveforms are segmented into ISO intervals, P subwave, QRS complex and T subwave respectively in the first HMM layer where expert-annotation assisted Baum-Welch algorithm is utilized in HMM modeling. Then the corresponding interval features are selected and applied to categorize the ECG into normal type or abnormal type (PVC, APC) in the second HMM layer. For verifying the effectiveness of our algorithm on abnormal signal detection, we have developed an ECG body sensor network (BSN) platform, whereby real-time ECG signals are collected, transmitted, displayed and the corresponding classification outcomes are deduced and shown on the BSN screen. PMID:24681668

  3. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    Directory of Open Access Journals (Sweden)

    Thomas Penzel

    2016-10-01

    Full Text Available The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave.

  4. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    Science.gov (United States)

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  5. Application of Handheld Tele-ECG for Health Care Delivery in Rural India

    Directory of Open Access Journals (Sweden)

    Meenu Singh

    2014-01-01

    Full Text Available Telemonitoring is a medical practice that involves remotely monitoring patients who are not at the same location as the health care provider. The purpose of our study was to use handheld tele-electrocardiogram (ECG developed by Bhabha Atomic Research Center (BARC to identify heart conditions in the rural underserved population where the doctor-patient ratio is low and access to health care is difficult. The objective of our study was clinical validation of handheld tele-ECG as a screening tool for evaluation of cardiac diseases in the rural population. ECG was obtained in 450 individuals (mean age 31.49 ± 20.058 residing in the periphery of Chandigarh, India, from April 2011 to March 2013, using the handheld tele-ECG machine. The data were then transmitted to physicians in Postgraduate Institute of Medical Education and Research (PGIMER, Chandigarh, for their expert opinion. ECG was interpreted as normal in 70% individuals. Left ventricular hypertrophy (9.3% was the commonest abnormality followed closely by old myocardial infarction (5.3%. Patient satisfaction was reported to be ~95%. Thus, it can be safely concluded that tele-ECG is a portable, cost-effective, and convenient tool for diagnosis and monitoring of heart diseases and thus improves quality and accessibility, especially in rural areas.

  6. A Novel Automatic Detection System for ECG Arrhythmias Using Maximum Margin Clustering with Immune Evolutionary Algorithm

    Directory of Open Access Journals (Sweden)

    Bohui Zhu

    2013-01-01

    Full Text Available This paper presents a novel maximum margin clustering method with immune evolution (IEMMC for automatic diagnosis of electrocardiogram (ECG arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias.

  7. Pertinence between the tombstoning electrocardiographic pattern of ST-segment change and infarcted artery orientation in acute myocardial infarction

    International Nuclear Information System (INIS)

    Deng Min; Ma Qianjun; Song Jianping

    2005-01-01

    Objective: The aim of this study is to address the pertinence between the tombstoning electrocardiographic pattern of ST-segment change and infracted artery orientation in acute myocardial infarction. Methods: The study investigated 104 patients with AMI, who subsequently underwent angiography. In this population, 19 patients had a definite tombstoning pattern on their admission ECG. Results: Between tombstoning ECGs and non-tombstoning, campared CAG, the results were as follows: tombstoning ECGs were more strongly associated with anterior infarction and significantly influence the left anterior descending (LAD) artery (P<0.001); LAD occlusions were significantly more severe, mostly proximal (P<0.05, P<0.01); tombstoning ECGs were significantly greater incidence of occlusion of multivessel coronary artery (P<0.05). Conclusions: Although tombstoning ECGs correlates with the occlusion of a high-grade stenosis of the proximal LAD and severe abnormal ventricle wall motion, it is still greatly necessary to reperfuse and revascularize so as to ameliorate the prognosis. (authors)

  8. Portable ECG design and application based on wireless sensor network

    Directory of Open Access Journals (Sweden)

    Gül Fatma TÜRKER

    2016-05-01

    Full Text Available In this study, in order to follow the heart signals of patients that needs to be monitored instantly and continuously without mobility restrictions, a portable electrocardiogram circuit is designed. After performing the detection, upgrading, cleaning and digitizing of ECG signal received from patient via disposable electrodes, ECG signals was performed that transmit to a central node with Wireless Sensor Network (WSN based on ZigBee 802.11.4 standard. Central node is connected to the serial port of a computer. Received data from the central node is processed on computer and continuous flow graph is obtained. The obligation to use wires for tracing patients’ ECG has been removed with this portable system. As it can be seen in this study, thanks to WSN’s property of forming network by itself and its augmentable loop property, the restrain of ECG signals to reach far away distances can be surmounted. The transmission of biological signals with WSN will light on many studies that follow of patients from a distance.

  9. A Novel Approach to ECG Classification Based upon Two-Layered HMMs in Body Sensor Networks

    Directory of Open Access Journals (Sweden)

    Wei Liang

    2014-03-01

    Full Text Available This paper presents a novel approach to ECG signal filtering and classification. Unlike the traditional techniques which aim at collecting and processing the ECG signals with the patient being still, lying in bed in hospitals, our proposed algorithm is intentionally designed for monitoring and classifying the patient’s ECG signals in the free-living environment. The patients are equipped with wearable ambulatory devices the whole day, which facilitates the real-time heart attack detection. In ECG preprocessing, an integral-coefficient-band-stop (ICBS filter is applied, which omits time-consuming floating-point computations. In addition, two-layered Hidden Markov Models (HMMs are applied to achieve ECG feature extraction and classification. The periodic ECG waveforms are segmented into ISO intervals, P subwave, QRS complex and T subwave respectively in the first HMM layer where expert-annotation assisted Baum-Welch algorithm is utilized in HMM modeling. Then the corresponding interval features are selected and applied to categorize the ECG into normal type or abnormal type (PVC, APC in the second HMM layer. For verifying the effectiveness of our algorithm on abnormal signal detection, we have developed an ECG body sensor network (BSN platform, whereby real-time ECG signals are collected, transmitted, displayed and the corresponding classification outcomes are deduced and shown on the BSN screen.

  10. Making Sense of the ECG - Cases for Self-Assessment Houghton Andrew R Gray David Making Sense of the ECG - Cases for Self-Assessment 290pp Hodder Education 9780340946893 034094689X [Formula: see text].

    Science.gov (United States)

    2010-10-27

    This practical, pocket-book approach to ECG interpretation accompanies the well-known text Making Sense of the ECG, by the same authors. It is also designed to be used alone to test knowledge of ECG interpretation and to make clinical decisions based on presented scenarios.

  11. Reliability of the exercise ECG in detecting silent ischemia in patients with prior myocardial infarction

    International Nuclear Information System (INIS)

    Yamagishi, Takashi; Matsuda, Yasuo; Satoh, Akira

    1991-01-01

    To assess the reliability of the exercise ECG in detecting silent ischemia, ECG results were compared with those of stress-redistribution thallium-201 single-photon emission computed tomography (SPECT) in 116 patients with prior myocardial infarction and in 20 normal subjects used as a control. The left ventricle (LV) was divided into 20 segmental images, which were scored blindly on a 5-point scale. The redistribution score was defined as thallium defect score of exercise subtracted by that of redistribution image and was used as a measure of amount of ischemic but viable myocardium. The upper limit of normal redistribution score (=4.32) was defined as mean+2 standard deviations derived from 20 normal subjects. Of 116 patients, 47 had the redistribution score above the normal range. Twenty-five (53%) of the 47 patients showed positive ECG response. Fourteen (20%) of the 69 patients, who had the normal redistribution score, showed positive ECG response. Thus, the ECG response had a sensitivity of 53% and a specificity of 80% in detecting transient ischemia. Furthermore, the 116 patients were subdivided into 4 groups according to the presence or absence of chest pain and ECG change during exercise. Fourteen patients showed both chest pain and ECG change and all these patients had the redistribution score above the normal range. Twenty-five patients showed ECG change without chest pain and 11 (44%) of the 25 patients had the abnormal redistribution. Three (43%) of 7 patients who showed chest pain without ECG change had the abnormal redistribution score. Of 70 patients who had neither chest pain nor ECG change, 19 (27%) had the redistribution score above the normal range. Thus, limitations exist in detecting silent ischemia by ECG in patients with a prior myocardial infarction, because the ECG response to the exercise test may have a low degree of sensitivity and a high degree of false positive and false negative results in detecting silent ischemia. (author)

  12. Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

    Science.gov (United States)

    Schlegel, Todd T.

    2012-01-01

    Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward

  13. Simultaneous ECG-gated PET imaging of multiple mice

    International Nuclear Information System (INIS)

    Seidel, Jurgen; Bernardo, Marcelino L.; Wong, Karen J.; Xu, Biying; Williams, Mark R.; Kuo, Frank; Jagoda, Elaine M.; Basuli, Falguni; Li, Changhui; Griffiths, Gary L.

    2014-01-01

    Introduction: We describe and illustrate a method for creating ECG-gated PET images of the heart for each of several mice imaged at the same time. The method is intended to increase “throughput” in PET research studies of cardiac dynamics or to obtain information derived from such studies, e.g. tracer concentration in end-diastolic left ventricular blood. Methods: An imaging bed with provisions for warming, anesthetic delivery, etc., was fabricated by 3D printing to allow simultaneous PET imaging of two side-by-side mice. After electrode attachment, tracer injection and placement of the animals in the scanner field of view, ECG signals from each animal were continuously analyzed and independent trigger markers generated whenever an R-wave was detected in each signal. PET image data were acquired in “list” mode and these trigger markers were inserted into this list along with the image data. Since each mouse is in a different spatial location in the FOV, sorting of these data using trigger markers first from one animal and then the other yields two independent and correctly formed ECG-gated image sequences that reflect the dynamical properties of the heart during an “average” cardiac cycle. Results: The described method yields two independent ECG-gated image sequences that exhibit the expected properties in each animal, e.g. variation of the ventricular cavity volumes from maximum to minimum and back during the cardiac cycle in the processed animal with little or no variation in these volumes during the cardiac cycle in the unprocessed animal. Conclusion: ECG-gated image sequences for each of several animals can be created from a single list mode data collection using the described method. In principle, this method can be extended to more than two mice (or other animals) and to other forms of physiological gating, e.g. respiratory gating, when several subjects are imaged at the same time

  14. Distinct Fracture Patterns in Construction Steels for Reinforced Concrete under Quasistatic Loading— A Review

    Directory of Open Access Journals (Sweden)

    Fernando Suárez

    2018-03-01

    Full Text Available Steel is one of the most widely used materials in construction. Nucleation growth and coalescence theory is usually employed to explain the fracture process in ductile materials, such as many metals. The typical cup–cone fracture pattern has been extensively studied in the past, giving rise to numerical models able to reproduce this pattern. Nevertheless, some steels, such as the eutectoid steel used for manufacturing prestressing wires, does not show this specific shape but a flat surface with a dark region in the centre of the fracture area. Recent studies have deepened the knowledge on these distinct fracture patterns, shedding light on some aspects that help to understand how damage begins and propagates in each case. The numerical modelling of both fracture patterns have also been discussed and reproduced with different approaches. This work reviews the main recent advances in the knowledge on this subject, particularly focusing on the experimental work carried out by the authors.

  15. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  16. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    Science.gov (United States)

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  17. ECG Based Heart Arrhythmia Detection Using Wavelet Coherence and Bat Algorithm

    Science.gov (United States)

    Kora, Padmavathi; Sri Rama Krishna, K.

    2016-12-01

    Atrial fibrillation (AF) is a type of heart abnormality, during the AF electrical discharges in the atrium are rapid, results in abnormal heart beat. The morphology of ECG changes due to the abnormalities in the heart. This paper consists of three major steps for the detection of heart diseases: signal pre-processing, feature extraction and classification. Feature extraction is the key process in detecting the heart abnormality. Most of the ECG detection systems depend on the time domain features for cardiac signal classification. In this paper we proposed a wavelet coherence (WTC) technique for ECG signal analysis. The WTC calculates the similarity between two waveforms in frequency domain. Parameters extracted from WTC function is used as the features of the ECG signal. These features are optimized using Bat algorithm. The Levenberg Marquardt neural network classifier is used to classify the optimized features. The performance of the classifier can be improved with the optimized features.

  18. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    Science.gov (United States)

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. ECG movement artefacts can be greatly reduced with the aid of a movement absorbing device

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Wandall, Kirsten; Thorball, Jørgen

    2007-01-01

    Accurate ECG signal analysis can be confounded by electric lead, and/or electrode movements varying in origin from, for example, hiccups, tremor or patient restlessness. ECG signals recorded using either a conventional electrode holder or with the aid of an electrode holder capable of absorbing...... movement artefacts, were measured on a healthy human subject. Results show a greatly improved stability of the ECG signal recorded using an electrode holder capable of absorbing movement artefacts during periods of lead disturbance, and highlight the movement artefacts that develop when the recording lead...... of a conventional ECG electrode holder is tugged or pulled during theperiod of monitoring. It is concluded that the new design of ECG electrode holder will not only enable clearer signal recordings for clinical assessment, but will reduce the ECG artefacts associated with the transportation of patients, and may...

  20. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Sleep disorders are typically investigated by means of polysomnographic recordings. We have analyzed 70 eight-hour single-channel ECG recordings to find out to which extent sleep apneas may be detected from the ECG alone...

  1. Chaos control applied to cardiac rhythms represented by ECG signals

    International Nuclear Information System (INIS)

    Borem Ferreira, Bianca; Amorim Savi, Marcelo; Souza de Paula, Aline

    2014-01-01

    The control of irregular or chaotic heartbeats is a key issue in cardiology. In this regard, chaos control techniques represent a good alternative since they suggest treatments different from those traditionally used. This paper deals with the application of the extended time-delayed feedback control method to stabilize pathological chaotic heart rhythms. Electrocardiogram (ECG) signals are employed to represent the cardiovascular behavior. A mathematical model is employed to generate ECG signals using three modified Van der Pol oscillators connected with time delay couplings. This model provides results that qualitatively capture the general behavior of the heart. Controlled ECG signals show the ability of the strategy either to control or to suppress the chaotic heart dynamics generating less-critical behaviors. (paper)

  2. ECG scaling properties of cardiac arrhythmias using detrended fluctuation analysis

    International Nuclear Information System (INIS)

    Rodriguez, E; Echeverria, J C; Alvarez-Ramirez, J; Lerma, C

    2008-01-01

    We applied detrended fluctuation analysis to characterize at very short time scales during episodes of cardiac arrhythmias the raw electrocardiogram (ECG) waveform, aiming to get a global insight into its dynamical behaviour in patients who experienced sudden death. We found that in 15 recordings involving different types of arrhythmias (taken from PhysioNet's Sudden Cardiac Death Holter Database), the ECG waveform, besides showing a less-random dynamics, becomes more regular during bigeminy, ventricular tachycardia or even atrial fibrillation and ventricular fibrillation. The ECG waveform scaling properties thus suggest that reduced complexity dominates the underlying mechanisms of arrhythmias. Among other explanations, this may result from shorted or restricted (i.e. less diverse) pathways of conduction of the electrical activity within ventricles

  3. Classification of a Driver's cognitive workload levels using artificial neural network on ECG signals.

    Science.gov (United States)

    Tjolleng, Amir; Jung, Kihyo; Hong, Wongi; Lee, Wonsup; Lee, Baekhee; You, Heecheon; Son, Joonwoo; Park, Seikwon

    2017-03-01

    An artificial neural network (ANN) model was developed in the present study to classify the level of a driver's cognitive workload based on electrocardiography (ECG). ECG signals were measured on 15 male participants while they performed a simulated driving task as a primary task with/without an N-back task as a secondary task. Three time-domain ECG measures (mean inter-beat interval (IBI), standard deviation of IBIs, and root mean squared difference of adjacent IBIs) and three frequencydomain ECG measures (power in low frequency, power in high frequency, and ratio of power in low and high frequencies) were calculated. To compensate for individual differences in heart response during the driving tasks, a three-step data processing procedure was performed to ECG signals of each participant: (1) selection of two most sensitive ECG measures, (2) definition of three (low, medium, and high) cognitive workload levels, and (3) normalization of the selected ECG measures. An ANN model was constructed using a feed-forward network and scaled conjugate gradient as a back-propagation learning rule. The accuracy of the ANN classification model was found satisfactory for learning data (95%) and testing data (82%). Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. ECG-manifest and ECG-silent dipyridamole technetium-99m sestamibi SPET perfusion defects in patients with ischaemic heart disease

    International Nuclear Information System (INIS)

    Galli, M.; Marcassa, C.; Bosimini, E.; Zoccarato, O.; Comazzi, F.; Giannuzzi, P.

    1997-01-01

    To investigate the relationship between ECG changes and perfusion abnormalities, body surface maps were recorded during dipyridamole infusion in 55 subjects (11 normals and 44 patients with ischaemic heart disease) undergoing dipyridamole technetium-99m sestamibi single-photon emission tomography (SPET). All had a normal resting ECG. The extent and severity of the sestamibi defect were quantified. New negative areas in the isointegral maps and rest-dipyridamole map differences >2 SD from normal limits were considered abnormal. After dipyridamole in normals, neither perfusion defects nor ≥1 mm ST segment depression on 12-lead ECG nor new negative areas in isointegral maps occurred. In patients, dipyridamole induced new perfusion defects in 35 (80%) but ST segment depression in only 18 (41%, P<0.001). Of the 35 patients with perfusion defects, 17 (49%, group 1) showed ST segment depression, while the other 18 (51%, group 2) did not. Abnormal body surface maps were found in 100% of group 1 and 88% of group 2 patients (NS). In group 1, the provoked hypoperfusion was of greater extent (P=0.007) and severity (P=0.01) and the onset of map abnormalities was significantly earlier (P<0.001) than in group 2; time to map abnormalities was also significantly shorter than time to ST segment depression (P=0.01). In the 35 patients with complete scintigraphic, body map and angiographic data, the severity of reversible perfusion defect proved to be the strongest correlate of ST segment depression upon logistic regression analysis. Thus, sestamibi SPET abnormalities after dipyridamole are almost always associated with electrical changes on body surface maps, suggesting myocardial ischaemia as their cause. The much less common 12-lead ECG changes are slower to appear and reflect a more severe hypoperfusion. (orig./MG). With 5 figs., 4 tabs

  5. Evaluating ECG and carboxyhemoglobin changes due to smoking narghile.

    Science.gov (United States)

    Yıldırım, Fazıl; Çevik, Yunsur; Emektar, Emine; Çorbacıoğlu, Şeref Kerem; Katırcı, Yavuz

    2016-10-01

    This study aimed to investigate whether increased carboxyhemoglobin (COHB) levels and ECG changes, which associated with fatal ventricular dysrhythmias, including increased QT, P-wave and T peak (Tp)-Tend (Te) dispersion, can be detected after smoking narghile, which is a traditional method of smoking tobacco that is smoked from hookah device. After local ethics committee approval, this prospective study was conducted using healthy volunteer subjects at a "narghile café," which is used by people smoking narghile in an open area. Before beginning to smoke narghile, all subjects' 12-lead electrocardiographs (ECG), measurements of COHB levels, and vital signs were recorded. After smoking narghile for 30 min, the recording of the 12-lead ECGs and the measurements of COHB level and all vital signs were repeated. The mean age of subjects was 26.8 ± 6.2 years (min-max: 18-40), and 28 subjects (84.8%) were male. Before smoking narghile, the median value of subjects' COHB levels was 1.3% (min-max: 0-6), whereas after smoking, the median value of COHB was 23.7% (min-max: 6-44), a statistically significant increase (p < 0.001). Analysis of the subjects' ECG changes after smoking narghile showed that dispersions of QT, QTc, P-wave and Tp-Te were increased, and all changes were statistically significant (p < 0.001 for all parameters). Although, especially among young people, it is commonly thought that smoking narghile has less harmful or toxic effects than other tobacco products. The results of this study and past studies clearly demonstrated that smoking narghile can cause several ECG changes - including increased QT, P-wave and Tp-Te dispersion - which can be associated with ventricular dysrhythmias.

  6. Association between obesity and ECG variables in children and adolescents: A cross-sectional study.

    Science.gov (United States)

    Sun, Guo-Zhe; Li, Yang; Zhou, Xing-Hu; Guo, Xiao-Fan; Zhang, Xin-Gang; Zheng, Li-Qiang; Li, Yuan; Jiao, Yun-DI; Sun, Ying-Xian

    2013-12-01

    Obesity exhibits a wide variety of electrocardiogram (ECG) abnormalities in adults, which often lead to cardiovascular events. However, there is currently no evidence of an association between obesity and ECG variables in children and adolescents. The present study aimed to explore the associations between obesity and ECG intervals and axes in children and adolescents. A cross-sectional observational study of 5,556 students aged 5-18 years was performed. Anthropometric data, blood pressure and standard 12-lead ECGs were collected for each participant. ECG variables were measured manually based on the temporal alignment of simultaneous 12 leads using a CV200 ECG Work Station. Overweight and obese groups demonstrated significantly longer PR intervals, wider QRS durations and leftward shifts of frontal P-wave, QRS and T-wave axes, while the obese group also demonstrated significantly higher heart rates, compared with normal weight groups within normotensive or hypertensive subjects (Pobesity was also associated with longer PR intervals, wider QRS duration and a leftward shift of frontal ECG axes compared with normal waist circumference (WC) within normotensive or hypertensive subjects (Paffecting the ECG variables. Furthermore, the ECG variables, including PR interval, QRS duration and frontal P-wave, QRS and T-wave axes, were significantly linearly correlated with body mass index, WC and waist-to-height ratio adjusted for age, gender, ethnicity and blood pressure. However, there was no significant association between obesity and the corrected QT interval (P>0.05). The results of the current study indicate that in children and adolescents, general and abdominal obesity is associated with longer PR intervals, wider QRS duration and a leftward shift of frontal P-wave, QRS and T-wave axes, independent of age, gender, ethnicity and blood pressure.

  7. The Telemetric and Holter ECG Warehouse Initiative (THEW): a Data Repository for the Design, Implementation and Validation of ECG-related Technologies

    Science.gov (United States)

    Couderc, Jean-Philippe

    2011-01-01

    We present an initiative supported by the National Heart Lung, and Blood Institute and the Food and Drug Administration for the development of a repository containing continuous electrocardiographic information to be shared with the worldwide scientific community. We believe that sharing data reinforces open scientific inquiry. It encourages diversity of analysis and opinion while promoting new research and facilitating the education of new researchers. In this paper, we present the resources available in this initiative for the scientific community. We describe the set of ECG signals currently hosted and we briefly discuss the associated clinical information (medical history. Disease and study-specific endpoints) and software tools we propose. Currently, the repository contains more than 250GB of data from eight clinical studies including healthy individuals and cardiac patients. This data is available for the development, implementation and validation of technologies related to body-surface ECGs. To conclude, the Telemetric and Holter ECG Warehouse (THEW) is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. PMID:21097349

  8. Measurement of ventricular function by ECG gating during atrial fibrillation

    International Nuclear Information System (INIS)

    Bacharach, S.L.; Green, M.V.; Bonow, R.O.; Findley, S.L.; Ostrow, H.G.; Johnston, G.S.

    1981-01-01

    The assumptions necessary to perform ECG-gated cardiac studies are seemingly not valid for patients in atrial fibrillation (AF). To evaluate the effect of AF on equilibrium gated scintigraphy, beat-by-beat measurements of left-ventricular function were made on seven subjects in AF (mean heart rate 64 bpm), using a high-efficiency nonimaging detector. The parameters evaluated were ejection fraction (EF), time to end-systole (TES), peak rates of ejection and filling (PER,PFR), and their times of occurrence (TPER, TPFR). By averaging together single-beat values of EF, PER, etc., it was possible to determine the true mean values of these parameters. The single-beam mean values were compared with the corresponding parameters calculated from one ECG-gated time-activity curve (TAC) obtained by superimposing all the single-beat TACs irrespective of their length. For this population with slow heart rates, we find that the values for EF, etc., produced from ECG-gated time-activity curves, are very similar to those obtained from the single-beat data. Thus use of ECG gating at low heart rates may allow reliable estimation of average cardiac function even in subjects with AF

  9. Wireless and Non-contact ECG Measurement System – the “Aachen SmartChair”

    Directory of Open Access Journals (Sweden)

    A. Aleksandrowicz

    2007-01-01

    Full Text Available This publication describes a measurement system that obtains an electrocardiogram (ECG by capacitively coupled electrodes. Fordemonstration purposes, this measurement system was integrated into an off-the-shelf office chair (so-called “Aachen SmartChair”.Whereas in usual clinical applications adhesive, conductively-coupled electrodes have to be attached to the skin, the described system is able to measure an ECG without direct skin contact through the cloth. A wireless communication module was integrated for transmitting theECG data to a PC or to an ICU patient monitor. For system validation, a classical ECG with conductive electrodes and an oxygensaturation signal (SpO2 were obtained simultaneously. Finally, system-specific problems of the presented device are discussed.

  10. Comparing IM Residents with EM Resident for Their Skills of ECG Interpretation and Outlining Management Plan Accordingly

    Directory of Open Access Journals (Sweden)

    Hamid Reza Karimpoor Tari

    2009-06-01

    Full Text Available Background and Purpose: Electrocardiogram (ECG is one of the most commonly performed investigations in cardiac diseases and ECG abnormalities can reveal the early manifestations of cardiac ischemia, metabolic disorders, or life-threatening disrhythmias. Misinterpretation of ECG and its consequent mistreatment or performing inessential  interventions may cause life-threatening cardiac events. Since EM residents and internal medicine (IM residents are usually the first to visit at bedside and start treatments based on patient’s ECG, we intended to evaluate the ability of EM residents to interpret ECGs and to compare it with that of IM residents using various ECG samples.Method: 63 participants including 33 IM residents and 30 EM residents from two education hospitals of Shahid Beheshti University of Medical Sciences were enrolled in our study. A diagnosis test consisting of 15 ECG samples associated with a questionnaire containing questions about gender, academic year and proficiency in ECG interpretation was taken from all participants. This study was conducted under the supervision of a cardiologist and an emergency specialist who supervised the ECG selection, answers and scoring of each ECG. The maximum score for each ECG was 6 which were given to a completely correct diagnosis and -0.25 negative point was given if the answer was wrong or any differential diagnosis was mentioned. After the test, the answer sheets were collected and wereanalyzed with SPSS program, by two of study authors who were kept blind to the real identities of participants.Results: After classification of groups, the overall mean score was 45.5/100 (38-60. The mean score of IM and EM residents was 56.0/100 (44.9-72 and 38.9/100 (31.5-45.5, respectively (p< 0.001.No significant correlation was found between the diagnosis scores and participant’s self-judgment on her/his ECG interpretation skills (p=0.897, r=0.017. Five ECGs were considered as the most important and

  11. Locally-adaptive Myriad Filters for Processing ECG Signals in Real Time

    Directory of Open Access Journals (Sweden)

    Nataliya Tulyakova

    2017-03-01

    Full Text Available The locally adaptive myriad filters to suppress noise in electrocardiographic (ECG signals in almost in real time are proposed. Statistical estimates of efficiency according to integral values of such criteria as mean square error (MSE and signal-to-noise ratio (SNR for the test ECG signals sampled at 400 Hz embedded in additive Gaussian noise with different values of variance are obtained. Comparative analysis of adaptive filters is carried out. High efficiency of ECG filtering and high quality of signal preservation are demonstrated. It is shown that locally adaptive myriad filters provide higher degree of suppressing additive Gaussian noise with possibility of real time implementation.

  12. Real-time QRS detection using integrated variance for ECG gated cardiac MRI

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2016-09-01

    Full Text Available During magnetic resonance imaging (MRI, a patient’s vital signs are required for different purposes. In cardiac MRI (CMR, an electrocardiogram (ECG of the patient is required for triggering the image acquisition process. However, a reliable QRS detection of an ECG signal acquired inside an MRI scanner is a challenging task due to the magnetohydrodynamic (MHD effect which interferes with the ECG. The aim of this work was to develop a reliable QRS detector usable inside the MRI which also fulfills the standards for medical devices (IEC 60601-2-27. Therefore, a novel real-time QRS detector based on integrated variance measurements is presented. The algorithm was trained on ANSI/AAMI EC13 test waveforms and was then applied to two databases with 12-lead ECG signals recorded inside and outside an MRI scanner. Reliable results for both databases were achieved for the ECG signals recorded inside (DBMRI: sensitivity Se = 99.94%, positive predictive value +P = 99.84% and outside (DBInCarT: Se = 99.29%, +P = 99.72% the MRI. Due to the accurate R-peak detection in real-time this can be used for monitoring and triggering in MRI exams.

  13. Distinct longitudinal patterns of absenteeism and their antecedents in full-time Australian employees.

    Science.gov (United States)

    Magee, Christopher A; Caputi, Peter; Lee, Jeong Kyu

    2016-01-01

    This paper investigated distinct longitudinal trajectories of absenteeism over time, and underlying demographic, work, and health antecedents. Data from the Household, Income, and Labor Dynamics in Australia Survey were used; this is a panel study of a representative sample of Australian households. This paper focused on 2,481 full-time employees across a 5-year period. Information on annual sick leave and relevant sociodemographic, work, and health-related factors was collected through interviews and self-completed surveys. Growth mixture modeling indicated 4 distinct longitudinal patterns of absenteeism over time. The moderate absenteeism trajectory (34.8%) of the sample had 4-5 days of sick leave per year and was used as the reference group. The low absenteeism trajectory (33.5%) had 1-2 days of absenteeism per year, while the no absenteeism trajectory (23.6%) had very low rates of absenteeism (absenteeism (>11 days per year). Compared with the moderate absenteeism trajectory, the high absenteeism trajectory was characterized by poor health; the no absenteeism and low absenteeism trajectories had better health but may also reflect processes relating to presenteeism. These results provide important insights into the nature of absenteeism in Australian employees, and suggest that different patterns of absenteeism over time could reflect a range of demographic, work, and health related factors. (c) 2016 APA, all rights reserved).

  14. ECG Sensor Verification System with Mean-Interval Algorithm for Handling Sport Issue

    Directory of Open Access Journals (Sweden)

    Kuo-Kun Tseng

    2016-01-01

    Full Text Available With the development of biometric verification, we proposed a new algorithm and personal mobile sensor card system for ECG verification. The proposed new mean-interval approach can identify the user quickly with high accuracy and consumes a small amount of flash memory in the microprocessor. The new framework of the mobile card system makes ECG verification become a feasible application to overcome the issues of a centralized database. For a fair and comprehensive evaluation, the experimental results have been tested on public MIT-BIH ECG databases and our circuit system; they confirm that the proposed scheme is able to provide excellent accuracy and low complexity. Moreover, we also proposed a multiple-state solution to handle the heat rate changes of sports problem. It should be the first to address the issue of sports in ECG verification.

  15. ECG signal performance de-noising assessment based on threshold tuning of dual-tree wavelet transform.

    Science.gov (United States)

    El B'charri, Oussama; Latif, Rachid; Elmansouri, Khalifa; Abenaou, Abdenbi; Jenkal, Wissam

    2017-02-07

    Since the electrocardiogram (ECG) signal has a low frequency and a weak amplitude, it is sensitive to miscellaneous mixed noises, which may reduce the diagnostic accuracy and hinder the physician's correct decision on patients. The dual tree wavelet transform (DT-WT) is one of the most recent enhanced versions of discrete wavelet transform. However, threshold tuning on this method for noise removal from ECG signal has not been investigated yet. In this work, we shall provide a comprehensive study on the impact of the choice of threshold algorithm, threshold value, and the appropriate wavelet decomposition level to evaluate the ECG signal de-noising performance. A set of simulations is performed on both synthetic and real ECG signals to achieve the promised results. First, the synthetic ECG signal is used to observe the algorithm response. The evaluation results of synthetic ECG signal corrupted by various types of noise has showed that the modified unified threshold and wavelet hyperbolic threshold de-noising method is better in realistic and colored noises. The tuned threshold is then used on real ECG signals from the MIT-BIH database. The results has shown that the proposed method achieves higher performance than the ordinary dual tree wavelet transform into all kinds of noise removal from ECG signal. The simulation results indicate that the algorithm is robust for all kinds of noises with varying degrees of input noise, providing a high quality clean signal. Moreover, the algorithm is quite simple and can be used in real time ECG monitoring.

  16. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    Science.gov (United States)

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  17. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Wang Rui; Zhang Zhaoqi; Xu Lei; Ma Qin; He Yi; Lu Dongxu; Yu Wei; Fan Zhanming

    2011-01-01

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 ± 9.57 HU vs. 72.63 ± 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 ± 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  18. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Rui, E-mail: rui_wang1979@yahoo.cn [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Qin, E-mail: tel1367@gmail.com [Department of Emergency, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); He Yi, E-mail: heyi139@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lu Dongxu, E-mail: larry.hi@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2011-11-15

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 {+-} 9.57 HU vs. 72.63 {+-} 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 {+-} 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  19. Unobtrusive ECG monitoring in the NICU using a capacitive sensing array

    International Nuclear Information System (INIS)

    Atallah, L; Meftah, M; Schellekens, M; Serteyn, A; Vullings, R; Bergmans, J W M; Osagiator, A; Oetomo, S Bambang

    2014-01-01

    The thin skin of preterm babies is easily damaged by adhesive electrodes, tapes, chest drains and needle-marks. The scars caused could be disfiguring or disabling to 10% of preterm newborns. Capacitive sensors present an attractive option for pervasively monitoring neonatal ECG, and can be embedded in a support system or even a garment worn by the neonate. This could improve comfort and reduce pain aiding better recovery as well as avoiding the scars caused by adhesive electrodes. In this work, we investigate the use of an array of capacitive sensors unobtrusively embedded in a mattress and used in a clinical environment for 15 preterm neonates. We also describe the analysis framework including the fusion of information from all sensors to provide a more accurate ECG signal. We propose a channel selection strategy as well as a method using physiological information to obtain a reliable ECG signal. When sensor coverage is well attained, results for both instantaneous heart rate and ECG signal shape analysis are very encouraging. The study also provides several insights on important factors affecting the results. These include the effect of textile type, number of layers, interferences (e.g. people walking by), motion severity and interventions. Incorporating this knowledge in the design of a capacitive sensing system would be crucial in ensuring that these sensors provide a reliable ECG signal when embedded in a neonatal support system. (paper)

  20. ECG interpretation in Emergency Department residents: an update and e-learning as a resource to improve skills.

    Science.gov (United States)

    Barthelemy, Francois X; Segard, Julien; Fradin, Philippe; Hourdin, Nicolas; Batard, Eric; Pottier, Pierre; Potel, Gilles; Montassier, Emmanuel

    2017-04-01

    ECG interpretation is a pivotal skill to acquire during residency, especially for Emergency Department (ED) residents. Previous studies reported that ECG interpretation competency among residents was rather low. However, the optimal resource to improve ECG interpretation skills remains unclear. The aim of our study was to compare two teaching modalities to improve the ECG interpretation skills of ED residents: e-learning and lecture-based courses. The participants were first-year and second-year ED residents, assigned randomly to the two groups. The ED residents were evaluated by means of a precourse test at the beginning of the study and a postcourse test after the e-learning and lecture-based courses. These evaluations consisted of the interpretation of 10 different ECGs. We included 39 ED residents from four different hospitals. The precourse test showed that the overall average score of ECG interpretation was 40%. Nineteen participants were then assigned to the e-learning course and 20 to the lecture-based course. Globally, there was a significant improvement in ECG interpretation skills (accuracy score=55%, P=0.0002). However, this difference was not significant between the two groups (P=0.14). Our findings showed that the ECG interpretation was not optimal and that our e-learning program may be an effective tool for enhancing ECG interpretation skills among ED residents. A large European study should be carried out to evaluate ECG interpretation skills among ED residents before the implementation of ECG learning, including e-learning strategies, during ED residency.

  1. A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications.

    Science.gov (United States)

    Kim, Hyejung; Van Hoof, Chris; Yazicioglu, Refet Firat

    2011-01-01

    This paper describes a mixed-signal ECG processing platform with an 12-bit ADC architecture that can adapt its sampling rate according to the input signals rate of change. This enables the sampling of ECG signals with significantly reduced data rate without loss of information. The presented adaptive sampling scheme reduces the ADC power consumption, enables the processing of ECG signals with lower power consumption, and reduces the power consumption of the radio while streaming the ECG signals. The test results show that running a CWT-based R peak detection algorithm using the adaptively sampled ECG signals consumes only 45.6 μW and it leads to 36% less overall system power consumption.

  2. IDENTIFIKASI SINYAL ECG IRAMA MYOCARDIAL ISCHEMIA DENGAN PENDEKATAN FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    Azhar A N

    2009-07-01

    Full Text Available The heart is one of vital organs in human body. Incidence of heart disease can be fatal for the patient. Myocardial ischemia, the disease that is often suffered by the human, is a disease due to clogged heart arteries blood vessels. One of the ways to detect this disease is by reading the graph output of electrocardiogram (ECG signal. ECG signal represents the condition and activity of the heart. Specialized knowledge, accuration and expertise are required to read ECG graph. To help expert or doctor, expert system based on artificial intelligent, such as Fuzzy Logic approach, can be applied to improve diagnostic accuracy and thoroughness. Fuzzy logic can be applied because of it flexibility to understand the linguistic variables used in identifying myocardial ischemia disease.

  3. Novel technical solutions for wireless ECG transmission & analysis in the age of the internet cloud.

    Science.gov (United States)

    Al-Zaiti, Salah S; Shusterman, Vladimir; Carey, Mary G

    2013-01-01

    Current guidelines recommend early reperfusion therapy for ST-elevation myocardial infarction (STEMI) within 90 min of first medical encounter. Telecardiology entails the use of advanced communication technologies to transmit the prehospital 12-lead electrocardiogram (ECG) to offsite cardiologists for early triage to the cath lab; which has been shown to dramatically reduce door-to-balloon time and total mortality. However, hospitals often find adopting ECG transmission technologies very challenging. The current review identifies seven major technical challenges of prehospital ECG transmission, including: paramedics inconvenience and transport delay; signal noise and interpretation errors; equipment malfunction and transmission failure; reliability of mobile phone networks; lack of compliance with the standards of digital ECG formats; poor integration with electronic medical records; and costly hardware and software pre-requisite installation. Current and potential solutions to address each of these technical challenges are discussed in details and include: automated ECG transmission protocols; annotatable waveform-based ECGs; optimal routing solutions; and the use of cloud computing systems rather than vendor-specific processing stations. Nevertheless, strategies to monitor transmission effectiveness and patient outcomes are essential to sustain initial gains of implementing ECG transmission technologies. © 2013.

  4. Distinct eye movement patterns enhance dynamic visual acuity.

    Science.gov (United States)

    Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.

  5. Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.

    Science.gov (United States)

    Al-Busaidi, Asiya M; Khriji, Lazhar; Touati, Farid; Rasid, Mohd Fadlee; Mnaouer, Adel Ben

    2017-09-12

    One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.

  6. Compressed ECG biometric: a fast, secured and efficient method for identification of CVD patient.

    Science.gov (United States)

    Sufi, Fahim; Khalil, Ibrahim; Mahmood, Abdun

    2011-12-01

    Adoption of compression technology is often required for wireless cardiovascular monitoring, due to the enormous size of Electrocardiography (ECG) signal and limited bandwidth of Internet. However, compressed ECG must be decompressed before performing human identification using present research on ECG based biometric techniques. This additional step of decompression creates a significant processing delay for identification task. This becomes an obvious burden on a system, if this needs to be done for a trillion of compressed ECG per hour by the hospital. Even though the hospital might be able to come up with an expensive infrastructure to tame the exuberant processing, for small intermediate nodes in a multihop network identification preceded by decompression is confronting. In this paper, we report a technique by which a person can be identified directly from his / her compressed ECG. This technique completely obviates the step of decompression and therefore upholds biometric identification less intimidating for the smaller nodes in a multihop network. The biometric template created by this new technique is lower in size compared to the existing ECG based biometrics as well as other forms of biometrics like face, finger, retina etc. (up to 8302 times lower than face template and 9 times lower than existing ECG based biometric template). Lower size of the template substantially reduces the one-to-many matching time for biometric recognition, resulting in a faster biometric authentication mechanism.

  7. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  8. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring

    OpenAIRE

    Amale Ankhili; Xuyuan Tao; Cédric Cochrane; David Coulon; Vladan Koncar

    2018-01-01

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The ...

  9. The event synchronous canceller algorithm removes maternal ECG from abdominal signals without affecting the fetal ECG

    NARCIS (Netherlands)

    Ungureanu, G.M.; Bergmans, J.W.M.; Oei, S.G.; Ungureanu, A.; Wolf, W.

    2009-01-01

    Fetal monitoring using abdominally recorded signals (ADS) allows physicians to detect occurring changes in the well-being state of the fetus from the beginning of pregnancy. Mainly based on the fetal electrocardiogram (fECG), it provides the long-term fetal heart rate (fHR) and assessment of the

  10. Scuba diving, acute left anterior descending artery occlusion and normal ECG

    Science.gov (United States)

    Doll, Sébastien Xavier; Rigamonti, Fabio; Roffi, Marco; Noble, Stéphane

    2013-01-01

    We report the case of an acute proximal occlusion of the left anterior descending coronary (LAD) artery following a scuba diving decompression accident and associated with normal ECG. Following uneventful thromboaspiration and coronary stenting, the patient was discharged on day  4 with secondary preventative therapies. A transthoracic echocardiography performed at this point showed a complete recovery compared with an initial localised akinesia involving the anterior and apical portion of the left ventricle upon admission. This case highlights that significant acute coronary lesions involving the LAD can occur without any ECG anomaly. The presence of acute and persistent angina associated with troponin elevation should prompt physicians to consider coronary angiography without delay, independently of the ECG results. PMID:23376677

  11. A configurable and low-power mixed signal SoC for portable ECG monitoring applications.

    Science.gov (United States)

    Kim, Hyejung; Kim, Sunyoung; Van Helleputte, Nick; Artes, Antonio; Konijnenburg, Mario; Huisken, Jos; Van Hoof, Chris; Yazicioglu, Refet Firat

    2014-04-01

    This paper describes a mixed-signal ECG System-on-Chip (SoC) that is capable of implementing configurable functionality with low-power consumption for portable ECG monitoring applications. A low-voltage and high performance analog front-end extracts 3-channel ECG signals and single channel electrode-tissue-impedance (ETI) measurement with high signal quality. This can be used to evaluate the quality of the ECG measurement and to filter motion artifacts. A custom digital signal processor consisting of 4-way SIMD processor provides the configurability and advanced functionality like motion artifact removal and R peak detection. A built-in 12-bit analog-to-digital converter (ADC) is capable of adaptive sampling achieving a compression ratio of up to 7, and loop buffer integration reduces the power consumption for on-chip memory access. The SoC is implemented in 0.18 μm CMOS process and consumes 32 μ W from a 1.2 V while heart beat detection application is running, and integrated in a wireless ECG monitoring system with Bluetooth protocol. Thanks to the ECG SoC, the overall system power consumption can be reduced significantly.

  12. Distinct neural patterns enable grasp types decoding in monkey dorsal premotor cortex

    Science.gov (United States)

    Hao, Yaoyao; Zhang, Qiaosheng; Controzzi, Marco; Cipriani, Christian; Li, Yue; Li, Juncheng; Zhang, Shaomin; Wang, Yiwen; Chen, Weidong; Chiara Carrozza, Maria; Zheng, Xiaoxiang

    2014-12-01

    Objective. Recent studies have shown that dorsal premotor cortex (PMd), a cortical area in the dorsomedial grasp pathway, is involved in grasp movements. However, the neural ensemble firing property of PMd during grasp movements and the extent to which it can be used for grasp decoding are still unclear. Approach. To address these issues, we used multielectrode arrays to record both spike and local field potential (LFP) signals in PMd in macaque monkeys performing reaching and grasping of one of four differently shaped objects. Main results. Single and population neuronal activity showed distinct patterns during execution of different grip types. Cluster analysis of neural ensemble signals indicated that the grasp related patterns emerged soon (200-300 ms) after the go cue signal, and faded away during the hold period. The timing and duration of the patterns varied depending on the behaviors of individual monkey. Application of support vector machine model to stable activity patterns revealed classification accuracies of 94% and 89% for each of the two monkeys, indicating a robust, decodable grasp pattern encoded in the PMd. Grasp decoding using LFPs, especially the high-frequency bands, also produced high decoding accuracies. Significance. This study is the first to specify the neuronal population encoding of grasp during the time course of grasp. We demonstrate high grasp decoding performance in PMd. These findings, combined with previous evidence for reach related modulation studies, suggest that PMd may play an important role in generation and maintenance of grasp action and may be a suitable locus for brain-machine interface applications.

  13. The electrocardiographic "triangular QRS-ST-T waveform" pattern in patients with ST-segment elevation myocardial infarction: Incidence, pathophysiology and clinical implications.

    Science.gov (United States)

    Cipriani, Alberto; D'Amico, Gianpiero; Brunello, Giulia; Perazzolo Marra, Martina; Migliore, Federico; Cacciavillani, Luisa; Tarantini, Giuseppe; Bauce, Barbara; Iliceto, Sabino; Corrado, Domenico; Zorzi, Alessandro

    A specific ECG pattern of presentation of ST-segment elevation acute myocardial infarction (STEMI), characterized by "triangular QRS-ST-T waveform" (TW), has been associated with poor in-hospital prognosis but longitudinal data on its incidence and clinical impact are lacking. We prospectively evaluated the incidence and prognostic meaning of the TW pattern in a cohort of consecutive STEMI patients. All STEMI patients who presented within 12h of symptoms onset and showed no complete bundle branch block or paced ventricular rhythm were included. The TW pattern was defined as a unique, giant wave (amplitude≥1mV) resulting from the fusion of the QRS complex, the ST-segment and the T-wave and showing a "triangular" morphology with a positive polarity in the leads exploring the ischemic region. Among 428 consecutive STEMI patients, 367 fulfilled the enrollment criteria. The TW pattern was identified in 5 of 367 patients (1.4%) on the admission ECG. This subset of STEMI patients with TW pattern significantly more often showed a left main coronary artery involvement (2/4, 50% vs 2/322, 0.6%; p<0.001), experienced ventricular fibrillation (5/5, 100% vs 35/362, 9.6% p<0.001), had cardiogenic shock (4/5, 80% vs. 14/362, 3.8%, p<0.001) and died during hospitalization (2/5, 40% vs 15/362, 4.1% p=0.02), compared with those with other ST-segment elevation ECG patterns. The TW pattern is an uncommon ECG finding, which reflects the presence of a large area of transmural myocardial ischemia and predicts cardiogenic shock accounting for high in-hospital mortality. When present, this ECG pattern should prompt aggressive therapeutic strategies, including mechanical support of circulation. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. ECG based biometrics verification system using LabVIEW

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Singla

    2010-07-01

    Full Text Available Biometric based authentication systems provide solutions to the problems in high security which remain with conventionalsecurity systems. In a biometric verification system, human’s biological parameters (such as voice, finger print,palm print or hand geometry, face, iris etc. are used to verify the authenticity of a person. These parameters are good to beused as biometric parameters but do not provide the guarantee that the person is present and alive. As voice can be copied,finger print can be picked from glass on synthetic skin and in face recognition system due to genetic factors identical twinsor father-son may have the same facial appearance. ECG does not have these problems. It can not be recorded without theknowledge of the person and ECG of every person is unique even identical twins have different ECG. In this paper an ECGbasedbiometrics verification system which was developed using Laboratory Virtual Instruments Engineering Workbench(LabVIEW version 7.1 is discussed. Experiments were conducted on the database stored in the laboratory of 20 individualshaving 10 samples each and the results revealed a false rejection rate (FRR of 3% and false acceptance rate (FAR of 3.21%.

  15. Self-organized neural network for the quality control of 12-lead ECG signals

    International Nuclear Information System (INIS)

    Chen, Yun; Yang, Hui

    2012-01-01

    Telemedicine is very important for the timely delivery of health care to cardiovascular patients, especially those who live in the rural areas of developing countries. However, there are a number of uncertainty factors inherent to the mobile-phone-based recording of electrocardiogram (ECG) signals such as personnel with minimal training and other extraneous noises. PhysioNet organized a challenge in 2011 to develop efficient algorithms that can assess the ECG signal quality in telemedicine settings. This paper presents our efforts in this challenge to integrate multiscale recurrence analysis with a self-organizing map for controlling the ECG signal quality. As opposed to directly evaluating the 12-lead ECG, we utilize an information-preserving transform, i.e. Dower transform, to derive the 3-lead vectorcardiogram (VCG) from the 12-lead ECG in the first place. Secondly, we delineate the nonlinear and nonstationary characteristics underlying the 3-lead VCG signals into multiple time-frequency scales. Furthermore, a self-organizing map is trained, in both supervised and unsupervised ways, to identify the correlations between signal quality and multiscale recurrence features. The efficacy and robustness of this approach are validated using real-world ECG recordings available from PhysioNet. The average performance was demonstrated to be 95.25% for the training dataset and 90.0% for the independent test dataset with unknown labels. (paper)

  16. ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Funke, M.; Obenauer, S.; Baum, F.; Grabbe, E.

    2003-01-01

    AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted κ statistics, extended κ statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended κ=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended κ=0.91 and 0.73, respectively), weighted κ=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not

  17. Making sense of the ECG: cases for self-assessment Making Sense of the ECG: Cases for Self-Assessment Houghton Andrew and Gray David Hodder Education £18.99 290pp 9780340946893 034094689X [Formula: see text].

    Science.gov (United States)

    2011-02-10

    This practical pocket-book approach to electrocardiogram (ECG) interpretation accompanies Making sense of the eCg by the same authors. it is also designed to be used alone to test knowledge of ECG interpretation and to make clinical decisions based on presented scenarios.

  18. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cristina Soguero-Ruiz

    2018-03-01

    Full Text Available Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT, and a complex-domain (heart rate variability (HRV. Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT. The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain.

  19. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Science.gov (United States)

    Mora-Jiménez, Inmaculada; Ramos-López, Javier; Quintanilla Fernández, Teresa; García-García, Antonio; Díez-Mazuela, Daniel; García-Alberola, Arcadi

    2018-01-01

    Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT)), and a complex-domain (heart rate variability (HRV)). Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages) and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT). The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain. PMID:29494497

  20. Noise Suppression in ECG Signals through Efficient One-Step Wavelet Processing Techniques

    Directory of Open Access Journals (Sweden)

    E. Castillo

    2013-01-01

    Full Text Available This paper illustrates the application of the discrete wavelet transform (DWT for wandering and noise suppression in electrocardiographic (ECG signals. A novel one-step implementation is presented, which allows improving the overall denoising process. In addition an exhaustive study is carried out, defining threshold limits and thresholding rules for optimal wavelet denoising using this presented technique. The system has been tested using synthetic ECG signals, which allow accurately measuring the effect of the proposed processing. Moreover, results from real abdominal ECG signals acquired from pregnant women are presented in order to validate the presented approach.

  1. Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

    Directory of Open Access Journals (Sweden)

    Minho Choi

    2016-05-01

    Full Text Available Non-intrusive electrocardiogram (ECG monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.

  2. Anatomic distribution of culprit lesions in patients with non-ST-segment elevation myocardial infarction and normal ECG.

    Science.gov (United States)

    Moustafa, Abdelmoniem; Abi-Saleh, Bernard; El-Baba, Mohammad; Hamoui, Omar; AlJaroudi, Wael

    2016-02-01

    In patients presenting with non-ST-elevation myocardial infarction (NSTEMI), left anterior descending (LAD) coronary artery and three-vessel disease are the most commonly encountered culprit lesions in the presence of ST depression, while one third of patients with left circumflex (LCX) artery related infarction have normal ECG. We sought to determine the predictors of presence of culprit lesion in NSTEMI patients based on ECG, echocardiographic, and clinical characteristics. Patients admitted to the coronary care unit with the diagnosis of NSTEMI between June 2012 and December 2013 were retrospectively identified. Admission ECG was interpreted by an electrophysiologist that was blinded to the result of the coronary angiogram. Patients were dichotomized into either normal or abnormal ECG group. The primary endpoint was presence of culprit lesion. Secondary endpoints included length of stay, re-hospitalization within 60 days, and in-hospital mortality. A total of 118 patients that were identified; 47 with normal and 71 with abnormal ECG. At least one culprit lesion was identified in 101 patients (86%), and significantly more among those with abnormal ECG (91.5% vs. 76.6%, P=0.041).The LAD was the most frequently detected culprit lesion in both groups. There was a higher incidence of two and three-vessel disease in the abnormal ECG group (P=0.041).On the other hand, there was a trend of higher LCX involvement (25% vs. 13.8%, P=0.18) and more normal coronary arteries in the normal ECG group (23.4% vs. 8.5%, P=0.041). On multivariate analysis, prior history of coronary artery disease (CAD) [odds ratio (OR) 6.4 (0.8-52)], male gender [OR 5.0 (1.5-17)], and abnormal admission ECG [OR 3.6 (1.12-12)], were independent predictors of a culprit lesion. There was no difference in secondary endpoints between those with normal and abnormal ECG. Among patients presenting with NSTEMI, prior history of CAD, male gender and abnormal admission ECG were independent predictors of a

  3. A Digital Compressed Sensing-Based Energy-Efficient Single-Spot Bluetooth ECG Node

    Directory of Open Access Journals (Sweden)

    Kan Luo

    2018-01-01

    Full Text Available Energy efficiency is still the obstacle for long-term real-time wireless ECG monitoring. In this paper, a digital compressed sensing- (CS- based single-spot Bluetooth ECG node is proposed to deal with the challenge in wireless ECG application. A periodic sleep/wake-up scheme and a CS-based compression algorithm are implemented in a node, which consists of ultra-low-power analog front-end, microcontroller, Bluetooth 4.0 communication module, and so forth. The efficiency improvement and the node’s specifics are evidenced by the experiments using the ECG signals sampled by the proposed node under daily activities of lay, sit, stand, walk, and run. Under using sparse binary matrix (SBM, block sparse Bayesian learning (BSBL method, and discrete cosine transform (DCT basis, all ECG signals were essentially undistorted recovered with root-mean-square differences (PRDs which are less than 6%. The proposed sleep/wake-up scheme and data compression can reduce the airtime over energy-hungry wireless links, the energy consumption of proposed node is 6.53 mJ, and the energy consumption of radio decreases 77.37%. Moreover, the energy consumption increase caused by CS code execution is negligible, which is 1.3% of the total energy consumption.

  4. A Digital Compressed Sensing-Based Energy-Efficient Single-Spot Bluetooth ECG Node.

    Science.gov (United States)

    Luo, Kan; Cai, Zhipeng; Du, Keqin; Zou, Fumin; Zhang, Xiangyu; Li, Jianqing

    2018-01-01

    Energy efficiency is still the obstacle for long-term real-time wireless ECG monitoring. In this paper, a digital compressed sensing- (CS-) based single-spot Bluetooth ECG node is proposed to deal with the challenge in wireless ECG application. A periodic sleep/wake-up scheme and a CS-based compression algorithm are implemented in a node, which consists of ultra-low-power analog front-end, microcontroller, Bluetooth 4.0 communication module, and so forth. The efficiency improvement and the node's specifics are evidenced by the experiments using the ECG signals sampled by the proposed node under daily activities of lay, sit, stand, walk, and run. Under using sparse binary matrix (SBM), block sparse Bayesian learning (BSBL) method, and discrete cosine transform (DCT) basis, all ECG signals were essentially undistorted recovered with root-mean-square differences (PRDs) which are less than 6%. The proposed sleep/wake-up scheme and data compression can reduce the airtime over energy-hungry wireless links, the energy consumption of proposed node is 6.53 mJ, and the energy consumption of radio decreases 77.37%. Moreover, the energy consumption increase caused by CS code execution is negligible, which is 1.3% of the total energy consumption.

  5. Arrhythmia recognition and classification using combined linear and nonlinear features of ECG signals.

    Science.gov (United States)

    Elhaj, Fatin A; Salim, Naomie; Harris, Arief R; Swee, Tan Tian; Ahmed, Taqwa

    2016-04-01

    Arrhythmia is a cardiac condition caused by abnormal electrical activity of the heart, and an electrocardiogram (ECG) is the non-invasive method used to detect arrhythmias or heart abnormalities. Due to the presence of noise, the non-stationary nature of the ECG signal (i.e. the changing morphology of the ECG signal with respect to time) and the irregularity of the heartbeat, physicians face difficulties in the diagnosis of arrhythmias. The computer-aided analysis of ECG results assists physicians to detect cardiovascular diseases. The development of many existing arrhythmia systems has depended on the findings from linear experiments on ECG data which achieve high performance on noise-free data. However, nonlinear experiments characterize the ECG signal more effectively sense, extract hidden information in the ECG signal, and achieve good performance under noisy conditions. This paper investigates the representation ability of linear and nonlinear features and proposes a combination of such features in order to improve the classification of ECG data. In this study, five types of beat classes of arrhythmia as recommended by the Association for Advancement of Medical Instrumentation are analyzed: non-ectopic beats (N), supra-ventricular ectopic beats (S), ventricular ectopic beats (V), fusion beats (F) and unclassifiable and paced beats (U). The characterization ability of nonlinear features such as high order statistics and cumulants and nonlinear feature reduction methods such as independent component analysis are combined with linear features, namely, the principal component analysis of discrete wavelet transform coefficients. The features are tested for their ability to differentiate different classes of data using different classifiers, namely, the support vector machine and neural network methods with tenfold cross-validation. Our proposed method is able to classify the N, S, V, F and U arrhythmia classes with high accuracy (98.91%) using a combined support

  6. A Portable ECG Recorder for Shipboard Use

    National Research Council Canada - National Science Library

    Ryack, Bernard L

    1989-01-01

    ...) that would serve as a medical consultant to the Independent Duty Corpsman. The system was designed for use on submarines where such common tools as x-rays and electrocardiograms (ECGs) are not available...

  7. Biosignal integrated circuit with simultaneous acquisition of ECG and PPG for wearable healthcare applications.

    Science.gov (United States)

    Kim, Hyungseup; Park, Yunjong; Ko, Youngwoon; Mun, Yeongjin; Lee, Sangmin; Ko, Hyoungho

    2018-01-01

    Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). The proposed IC is fabricated by using a standard 0.18 μm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 μA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 μVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.

  8. Fault Tolerant Neural Network for ECG Signal Classification Systems

    Directory of Open Access Journals (Sweden)

    MERAH, M.

    2011-08-01

    Full Text Available The aim of this paper is to apply a new robust hardware Artificial Neural Network (ANN for ECG classification systems. This ANN includes a penalization criterion which makes the performances in terms of robustness. Specifically, in this method, the ANN weights are normalized using the auto-prune method. Simulations performed on the MIT ? BIH ECG signals, have shown that significant robustness improvements are obtained regarding potential hardware artificial neuron failures. Moreover, we show that the proposed design achieves better generalization performances, compared to the standard back-propagation algorithm.

  9. Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT

    International Nuclear Information System (INIS)

    Xue Yuejun; Qian Nong; Shao Yanhui; Pan Changjie; Rong Weiliang; Xu Yiqun

    2012-01-01

    Objective: To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot, SAS). Methods: A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot, SAS). Data acquisition was at 60% R-R interval of the ECG presentation mode. The post-processing included maximum intensity projection (MIP), multiplanar reformation (MPR) and volume rendering (VR). The CTA image quality, radiation dose and rates of excellent images were evaluated. Results: The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images. The average effective dose of SAS-CTA was (0.22 ± 0.01)mSv, which was lower by 76.31% than that of DE-CTA. Conclusions: Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality. (authors)

  10. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.

    Science.gov (United States)

    Vandecasteele, Kaat; De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Paesschen, Wim Van; Huffel, Sabine Van; Hunyadi, Borbála

    2017-10-13

    Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.

  11. ECG dispersion mapping predicts clinical deterioration, measured by increase in the Simple Clinical Score.

    LENUS (Irish Health Repository)

    Kellett, J

    2012-01-01

    Objective: ECG dispersion mapping (ECG-DM) is a novel technique that reports abnormal ECG microalternations. We report the ability of ECG-DM to predict clinical deterioration of acutely ill medical patients, as measured by an increase in the Simple Clinical Score (SCS) the day after admission to hospital. Methods: 453 acutely ill medical patients (mean age 69.7 +\\/- 14.0 years) had the SCS recorded and ECGDM performed immediately after admission to hospital. Results: 46 patients had an SCS increase 20.8 +\\/- 7.6 hours after admission. Abnormal micro-alternations during left ventricular re-polarization had the highest association with SCS increase (p=0.0005). Logistic regression showed that only nursing home residence and abnormal micro-alternations during re-polarization of the left ventricle were independent predictors of SCS increase with an odds ratio of 2.84 and 3.01, respectively. Conclusion: ECG-DM changes during left ventricular re-polarization are independent predictors of clinical deterioration the day after hospital admission.

  12. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment

    Directory of Open Access Journals (Sweden)

    Kaat Vandecasteele

    2017-10-01

    Full Text Available Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG and photoplethysmography (PPG, are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.

  13. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    Science.gov (United States)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the

  14. Optimisation algorithms for ECG data compression.

    Science.gov (United States)

    Haugland, D; Heber, J G; Husøy, J H

    1997-07-01

    The use of exact optimisation algorithms for compressing digital electrocardiograms (ECGs) is demonstrated. As opposed to traditional time-domain methods, which use heuristics to select a small subset of representative signal samples, the problem of selecting the subset is formulated in rigorous mathematical terms. This approach makes it possible to derive algorithms guaranteeing the smallest possible reconstruction error when a bounded selection of signal samples is interpolated. The proposed model resembles well-known network models and is solved by a cubic dynamic programming algorithm. When applied to standard test problems, the algorithm produces a compressed representation for which the distortion is about one-half of that obtained by traditional time-domain compression techniques at reasonable compression ratios. This illustrates that, in terms of the accuracy of decoded signals, existing time-domain heuristics for ECG compression may be far from what is theoretically achievable. The paper is an attempt to bridge this gap.

  15. Automatic screening of obstructive sleep apnea from the ECG based on empirical mode decomposition and wavelet analysis

    International Nuclear Information System (INIS)

    Mendez, M O; Cerutti, S; Bianchi, A M; Corthout, J; Van Huffel, S; Matteucci, M; Penzel, T

    2010-01-01

    This study analyses two different methods to detect obstructive sleep apnea (OSA) during sleep time based only on the ECG signal. OSA is a common sleep disorder caused by repetitive occlusions of the upper airways, which produces a characteristic pattern on the ECG. ECG features, such as the heart rate variability (HRV) and the QRS peak area, contain information suitable for making a fast, non-invasive and simple screening of sleep apnea. Fifty recordings freely available on Physionet have been included in this analysis, subdivided in a training and in a testing set. We investigated the possibility of using the recently proposed method of empirical mode decomposition (EMD) for this application, comparing the results with the ones obtained through the well-established wavelet analysis (WA). By these decomposition techniques, several features have been extracted from the ECG signal and complemented with a series of standard HRV time domain measures. The best performing feature subset, selected through a sequential feature selection (SFS) method, was used as the input of linear and quadratic discriminant classifiers. In this way we were able to classify the signals on a minute-by-minute basis as apneic or nonapneic with different best-subset sizes, obtaining an accuracy up to 89% with WA and 85% with EMD. Furthermore, 100% correct discrimination of apneic patients from normal subjects was achieved independently of the feature extractor. Finally, the same procedure was repeated by pooling features from standard HRV time domain, EMD and WA together in order to investigate if the two decomposition techniques could provide complementary features. The obtained accuracy was 89%, similarly to the one achieved using only Wavelet analysis as the feature extractor; however, some complementary features in EMD and WA are evident

  16. Pain patterns during adolescence can be grouped into four pain classes with distinct profiles

    DEFF Research Database (Denmark)

    Holden, Sinead; Rathleff, Michael Skovdal; Roos, E. M.

    2018-01-01

    L (assessed by Euro-QoL 5D-3L). Latent class analysis was used to classify spatial pain patterns, based on the pain sites. The analysis included 2953 adolescents. RESULTS: Four classes were identified as follows: (1) little or no pain (63% of adolescents), (2) majority lower extremity pain (10%), (3) multi......-site bodily pain (22%) and (4) head and stomach pain (3%). The lower extremity multi-site pain group reported highest weekly sports participation (p ....001). Males were more likely to belong to the little or no pain class, whereas females were more likely to belong to the multi-site bodily pain class. CONCLUSIONS: Latent class analysis identified distinct classes of pain patterns in adolescents, characterized by sex, differences in HRQoL and sports...

  17. Manifold learning based ECG-free free-breathing cardiac CINE MRI.

    Science.gov (United States)

    Usman, Muhammad; Atkinson, David; Kolbitsch, Christoph; Schaeffter, Tobias; Prieto, Claudia

    2015-06-01

    To present and validate a manifold learning (ML)-based method that can estimate both cardiac and respiratory navigator signals from electrocardiogram (ECG)-free free-breathing cardiac magnetic resonance imaging (MRI) data to achieve self-gated retrospective CINE reconstruction. In this work the use of the ML method is demonstrated for 2D cardiac CINE to achieve both cardiac and respiratory self-gating without the need of an external navigator or ECG signal. This is achieved by sequentially applying ML to two sets of retrospectively reconstructed real-time images with differing temporal resolutions. A 1D cardiac signal is estimated by applying ML to high temporal resolution real-time images reconstructed from the acquired data. Using the estimated cardiac signal, a 1D respiratory signal was obtained by applying the ML method to low temporal resolution images reconstructed from the same acquired data for each cardiac cycle. Data were acquired in five volunteers with a 2D golden angle radial trajectory in a balanced steady-state free precession (b-SSFP) acquisition. The accuracy of the estimated cardiac signal was calculated as the standard deviation of the temporal difference between the estimated signal and the recorded ECG. The correlation between the estimated respiratory signal and standard pencil beam navigator signal was evaluated. Gated CINE reconstructions (20 cardiac phases per cycle, temporal resolution ∼30 msec) using the estimated cardiac and respiratory signals were qualitatively compared against conventional ECG-gated breath-hold CINE acquisitions. Accurate cardiac signals were estimated with the proposed method, with an error standard deviation in comparison to ECG lower than 20 msec. Respiratory signals estimated with the proposed method achieved a mean cross-correlation of 94% with respect to standard pencil beam navigator signals. Good quality visual scores of 2.80 ± 0.45 (scores from 0, bad, to 4, excellent quality) were observed for the

  18. Analysis of the cardiac motion in myocardial infarction by the ECG-synchronized CT

    International Nuclear Information System (INIS)

    Watanabe, Shigeru; Shimizu, Masahiko; Yoshida, Hideo; Morooka, Nobuhiro; Shukuya, Masaki

    1981-01-01

    The cardiac motion in patients with myocardial infarction was analyzed by the ECG-synchronized computed tomography (CT). For ECG synchronization, the ECG gating method and the data sorting method were used. By the ECG gating method, the gated cardiac images during 0.1 msec intervals at end-diastolic and the end-systolic phases were obtained. By the data sorting method, phasic CT images were reconstructed retrospectively by selecting appropriate data from a series of consecutive scans taken with simultaneous continuous ECG recordings. Six normal subjects and eight patients with myocardial infarction were studied by the ECG gating method, and 14 normal subjects and 25 patients with myocardial infarction were studied by the data sorting method. The end-diastolic and the end-systolic pictures at mid left ventricular level were superimposed and the cardiac borders were traced for the analysis (Fig. 4). Then the cardiac cross-sectional areas at each cardiac phase (40 msec) were calculated, and a cardiac area curve was obtained by plotting them consecutively. The cross-sectional images were divided into right anterior, right posterior, left anterior and left posterior segments. Cardiac area curves of the each segment were also obtained for further analysis. From these curves, the changing ratio of cardiac areas (maximum area - minimum area/maximum area) and the maximum area velocity in systole and diastole were calculated. On the images and the cardiac area curves in myocardial infarction patients, abnormal myocardial movements such as partial akinesis, hypokinesis or paradoxical movement were apparent asd the area of abnormal motions corresponded well with the location of infarction determined by ECG, RI scanning and angiography. A decrease of the changing ratio and the velocity in the infarction area were shown (Fig. 6, 7) and the functional disturbances were suggested during not only systole but diastole also. (author)

  19. Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems

    Science.gov (United States)

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290

  20. An evaluation of the ECG gated cardiac CT on old myocardial infarction

    International Nuclear Information System (INIS)

    Tanegashima, Kazuhiro; Tejima, Yasuaki; Nakasone, Noriyo; Hyodo, Haruo

    1984-01-01

    In order to examine the accuracy of ECG gated cardiac CT (G-CCT), G-CCT findings were compared with ECG and cardiac echographic findings in 25 cases of old myocardial infarction. From the detection rate according to the infarct area, abnormal findings in the anterior wall and the septum obtained from G-CCT were in good accordance with those from ECG. Although all of the G-CCT findings did not agree with those of cardiac echography in cases in which abnormal findings were seen in multiple areas, the detection rate of cardiac abnormal findings as a whole by G-CCT was the same as that by cardiac echography. (Namekawa K.)

  1. Noise Maps for Quantitative and Clinical Severity Towards Long-Term ECG Monitoring.

    Science.gov (United States)

    Everss-Villalba, Estrella; Melgarejo-Meseguer, Francisco Manuel; Blanco-Velasco, Manuel; Gimeno-Blanes, Francisco Javier; Sala-Pla, Salvador; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2017-10-25

    Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported

  2. Triagem pré-participação com ECG em recrutas militares

    Directory of Open Access Journals (Sweden)

    Alon Grossman

    2013-03-01

    Full Text Available FUNDAMENTO: Os achados e investigações adicionais necessários com base na triagem pré-participação com eletrocardiograma (ECG entre os recrutas militares estão mal definidos na literatura. OBJETIVOS: Este estudo foi elaborado para avaliar a taxa de achados anormais na triagem pré-participação com ECG em adultos jovens e as avaliações adicionais necessárias com base nestes resultados. MÉTODOS: Um estudo de coorte retrospectivo foi realizado no centro aero-médico da Força Aérea de Israel (IAF, para candidatos das unidades das academias de voo e de tropa s de elite. Os candidatos das unidades das Academias de voo e de elite passam por uma triagem pré-participação com ECG antes do alistamento nas Forças de Defesa de Israel (IDF. Desde 2010, todos os ECGs são realizados no centro aero-médico da IAF. Todos os ECGs realizados desde janeiro de 2010 foram analisados por um de três cardiologistas e todos aqueles nos quais resultados significativos foram identificados foram encaminhados para uma avaliação mais detalhada, a pedido do cardiologista. As causas de encaminhamento para avaliação posterior, as avaliações realizadas e os resultados dessas avaliações são notificados para a população de estudo. RESULTADOS: 1.455 ECGs foram realizados nos anos 2010-2011. Desses, 1.388 (95,39% foram interpretadas como normais. 67 indivíduos foram encaminhados para uma avaliação mais detalhada com base nos achados do ECG. Os achados mais comuns levando a uma avaliação mais detalhada foram alterações da onda T (16 casos, 23,88%, padrão de pré-excitação (14, 20,89% e critérios de voltagem para hipertrofia ventricular esquerda (11; 16,41%. Apenas 7 indivíduos (10,44% tinham resultados anormais que foram considerados clinicamente significativos no final da avaliação médica. CONCLUSÕES: A taxa de achados significantes levando à desqualificação para a atividade militar é extremamente baixa e o encaminhamento para

  3. Automatic detection of ECG electrode misplacement: a tale of two algorithms

    International Nuclear Information System (INIS)

    Xia, Henian; Garcia, Gabriel A; Zhao, Xiaopeng

    2012-01-01

    Artifacts in an electrocardiogram (ECG) due to electrode misplacement can lead to wrong diagnoses. Various computer methods have been developed for automatic detection of electrode misplacement. Here we reviewed and compared the performance of two algorithms with the highest accuracies on several databases from PhysioNet. These algorithms were implemented into four models. For clean ECG records with clearly distinguishable waves, the best model produced excellent accuracies (> = 98.4%) for all misplacements except the LA/LL interchange (87.4%). However, the accuracies were significantly lower for records with noise and arrhythmias. Moreover, when the algorithms were tested on a database that was independent from the training database, the accuracies may be poor. For the worst scenario, the best accuracies for different types of misplacements ranged from 36.1% to 78.4%. A large number of ECGs of various qualities and pathological conditions are collected every day. To improve the quality of health care, the results of this paper call for more robust and accurate algorithms for automatic detection of electrode misplacement, which should be developed and tested using a database of extensive ECG records. (paper)

  4. Interactive Videoconference Supported Teaching in Undergraduate Nursing: A Case Study for ECG

    Science.gov (United States)

    Celikkan, Ufuk; Senuzun, Fisun; Sari, Dilek; Sahin, Yasar Guneri

    2013-01-01

    This paper describes how interactive videoconference can benefit the Electrocardiography (ECG) skills of undergraduate nursing students. We have implemented a learning system that interactively transfers the visual and practical aspects of ECG from a nursing skills lab into a classroom where the theoretical part of the course is taught. The…

  5. Design of Low Power Algorithms for Automatic Embedded Analysis of Patch ECG Signals

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt

    , several different cable-free wireless patch-type ECG recorders have recently reached the market. One of these recorders is the ePatch designed by the Danish company DELTA. The extended monitoring period available with the patch recorders has demonstrated to increase the diagnostic yield of outpatient ECG....... Such algorithms could allow the real-time transmission of clinically relevant information to a central monitoring station. The first step in embedded ECG interpretation is the automatic detection of each individual heartbeat. An important part of this project was therefore to design a novel algorithm...

  6. A 58 nW ECG ASIC With Motion-Tolerant Heartbeat Timing Extraction for Wearable Cardiovascular Monitoring.

    Science.gov (United States)

    Da He, David; Sodini, Charles G

    2015-06-01

    An ASIC for wearable cardiovascular monitoring is implemented using a topology that takes advantage of the electrocardiogram's (ECG) waveform to replace the traditional ECG instrumentation amplifier, ADC, and signal processor with a single chip solution. The ASIC can extract heartbeat timings in the presence of baseline drift, muscle artifact, and signal clipping. The circuit can operate with ECGs ranging from the chest location to remote locations where the ECG magnitude is as low as 30 μV. Besides heartbeat detection, a midpoint estimation method can accurately extract the ECG R-wave timing, enabling the calculations of heart rate variability. With 58 nW of power consumption at 0.8 V supply voltage and 0.76 mm (2) of active die area in standard 0.18 μm CMOS technology, the ECG ASIC is sufficiently low power and compact to be suitable for long term and wearable cardiovascular monitoring applications under stringent battery and size constraints.

  7. Soil Bacterial and Fungal Communities Show Distinct Recovery Patterns during Forest Ecosystem Restoration.

    Science.gov (United States)

    Sun, Shan; Li, Song; Avera, Bethany N; Strahm, Brian D; Badgley, Brian D

    2017-07-15

    Bacteria and fungi are important mediators of biogeochemical processes and play essential roles in the establishment of plant communities, which makes knowledge about their recovery after extreme disturbances valuable for understanding ecosystem development. However, broad ecological differences between bacterial and fungal organisms, such as growth rates, stress tolerance, and substrate utilization, suggest they could follow distinct trajectories and show contrasting dynamics during recovery. In this study, we analyzed both the intra-annual variability and decade-scale recovery of bacterial and fungal communities in a chronosequence of reclaimed mined soils using next-generation sequencing to quantify their abundance, richness, β-diversity, taxonomic composition, and cooccurrence network properties. Bacterial communities shifted gradually, with overlapping β-diversity patterns across chronosequence ages, while shifts in fungal communities were more distinct among different ages. In addition, the magnitude of intra-annual variability in bacterial β-diversity was comparable to the changes across decades of chronosequence age, while fungal communities changed minimally across months. Finally, the complexity of bacterial cooccurrence networks increased with chronosequence age, while fungal networks did not show clear age-related trends. We hypothesize that these contrasting dynamics of bacteria and fungi in the chronosequence result from (i) higher growth rates for bacteria, leading to higher intra-annual variability; (ii) higher tolerance to environmental changes for fungi; and (iii) stronger influence of vegetation on fungal communities. IMPORTANCE Both bacteria and fungi play essential roles in ecosystem functions, and information about their recovery after extreme disturbances is important for understanding whole-ecosystem development. Given their many differences in phenotype, phylogeny, and life history, a comparison of different bacterial and fungal recovery

  8. A novel application of deep learning for single-lead ECG classification.

    Science.gov (United States)

    Mathews, Sherin M; Kambhamettu, Chandra; Barner, Kenneth E

    2018-06-04

    Detecting and classifying cardiac arrhythmias is critical to the diagnosis of patients with cardiac abnormalities. In this paper, a novel approach based on deep learning methodology is proposed for the classification of single-lead electrocardiogram (ECG) signals. We demonstrate the application of the Restricted Boltzmann Machine (RBM) and deep belief networks (DBN) for ECG classification following detection of ventricular and supraventricular heartbeats using single-lead ECG. The effectiveness of this proposed algorithm is illustrated using real ECG signals from the widely-used MIT-BIH database. Simulation results demonstrate that with a suitable choice of parameters, RBM and DBN can achieve high average recognition accuracies of ventricular ectopic beats (93.63%) and of supraventricular ectopic beats (95.57%) at a low sampling rate of 114 Hz. Experimental results indicate that classifiers built into this deep learning-based framework achieved state-of-the art performance models at lower sampling rates and simple features when compared to traditional methods. Further, employing features extracted at a sampling rate of 114 Hz when combined with deep learning provided enough discriminatory power for the classification task. This performance is comparable to that of traditional methods and uses a much lower sampling rate and simpler features. Thus, our proposed deep neural network algorithm demonstrates that deep learning-based methods offer accurate ECG classification and could potentially be extended to other physiological signal classifications, such as those in arterial blood pressure (ABP), nerve conduction (EMG), and heart rate variability (HRV) studies. Copyright © 2018. Published by Elsevier Ltd.

  9. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J.; Xu, J.

    2010-01-01

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 ± 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  10. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J. [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Xu, J., E-mail: xujianr@hotmail.co [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China)

    2010-10-15

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 {+-} 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  11. Pre-participation examination of competitive athletes: role of the ECG.

    Science.gov (United States)

    Hirzinger, Corinna; Froelicher, Victor F; Niebauer, Josef

    2010-08-01

    Sudden cardiac death in athletes is rare but has a wide social impact because it confronts the general population with the paradox that athletes perceived and admired as the fittest and healthiest suddenly drop dead during their sport. Mass media coverage is guaranteed in the case of sudden cardiac death of a top athlete, while other competitive and noncompetitive athletes of all ages, team members, sponsors, as well as huge parts of society remain puzzled and frightened. Therefore, debate is ongoing regarding how to minimize the number of fatalities, and the search continues for a cost-effective preparticipation screening for competitive athletes. Despite the fact that routine ECG screening would be widely available and rather inexpensive, debate continues regarding whether this should be part of initial screening for every athlete before starting to train at high intensity as well as during annual checkups. The role of ECGs in preparticipation examinations of competitive athletes is intensively discussed because there is a lack of strict criteria for which ECG findings should generate further workup. In this article, we analyze the main publications on sudden cardiac death, focusing on the benefit of ECG screening in preparticipation examination as it has been shown to be feasible and effective in identifying athletes at risk of sudden cardiac death. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Systematic analysis of ECG predictors of sinus rhythm maintenance after electrical cardioversion for persistent atrial fibrillation.

    Science.gov (United States)

    Lankveld, Theo; de Vos, Cees B; Limantoro, Ione; Zeemering, Stef; Dudink, Elton; Crijns, Harry J; Schotten, Ulrich

    2016-05-01

    Electrical cardioversion (ECV) is one of the rhythm control strategies in patients with persistent atrial fibrillation (AF). Unfortunately, recurrences of AF are common after ECV, which significantly limits the practical benefit of this treatment in patients with AF. The objectives of this study were to identify noninvasive complexity or frequency parameters obtained from the surface electrocardiogram (ECG) to predict sinus rhythm (SR) maintenance after ECV and to compare these ECG parameters with clinical predictors. We studied a wide variety of ECG-derived time- and frequency-domain AF complexity parameters in a prospective cohort of 502 patients with persistent AF referred for ECV. During 1-year follow-up, 161 patients (32%) maintained SR. The best clinical predictor of SR maintenance was antiarrhythmic drug (AAD) treatment. A model including clinical parameters predicted SR maintenance with a mean cross-validated area under the receiver operating characteristic curve (AUC) of 0.62 ± 0.05. The best single ECG parameter was the dominant frequency (DF) on lead V6. Combining several ECG parameters predicted SR maintenance with a mean AUC of 0.64 ± 0.06. Combining clinical and ECG parameters improved prediction to a mean AUC of 0.67 ± 0.05. Although the DF was affected by AAD treatment, excluding patients taking AADs did not significantly lower the predictive performance captured by the ECG. ECG-derived parameters predict SR maintenance during 1-year follow-up after ECV at least as good as known clinical predictors of rhythm outcome. The DF proved to be the most powerful ECG-derived predictor. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. A sub-nJ CMOS ECG classifier for wireless smart sensor.

    Science.gov (United States)

    Chollet, Paul; Pallas, Remi; Lahuec, Cyril; Arzel, Matthieu; Seguin, Fabrice

    2017-07-01

    Body area sensor networks hold the promise of more efficient and cheaper medical care services through the constant monitoring of physiological markers such as heart beats. Continuously transmitting the electrocardiogram (ECG) signal requires most of the wireless ECG sensor energy budget. This paper presents the analog implantation of a classifier for ECG signals that can be embedded onto a sensor. The classifier is a sparse neural associative memory. It is implemented using the ST 65 nm CMOS technology and requires only 234 pJ per classification while achieving a 93.6% classification accuracy. The energy requirement is 6 orders of magnitude lower than a digital accelerator that performs a similar task. The lifespan of the resulting sensor is 191 times as large as that of a sensor sending all the data.

  14. Automatic ECG analysis using principal component analysis and wavelet transformation

    OpenAIRE

    Khawaja, Antoun

    2007-01-01

    The main objective of this book is to analyse and detect small changes in ECG waves and complexes that indicate cardiac diseases and disorders. Detecting predisposition to Torsade de Points (TDP) by analysing the beat-to-beat variability in T wave morphology is the main core of this work. The second main topic is detecting small changes in QRS complex and predicting future QRS complexes of patients. Moreover, the last main topic is clustering similar ECG components in different groups.

  15. Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model

    International Nuclear Information System (INIS)

    Mäntynen, Ville; Konttila, Teijo; Stenroos, Matti

    2014-01-01

    Solving the inverse problem of electrocardiography (ECG) and magnetocardiography (MCG) is often referred to as cardiac source imaging. Spatial properties of ECG and MCG as imaging systems are, however, not well known. In this modelling study, we investigate the sensitivity and point-spread function (PSF) of ECG, MCG, and combined ECG+MCG as a function of source position and orientation, globally around the ventricles: signal topographies are modelled using a realistically-shaped volume conductor model, and the inverse problem is solved using a distributed source model and linear source estimation with minimal use of prior information. The results show that the sensitivity depends not only on the modality but also on the location and orientation of the source and that the sensitivity distribution is clearly reflected in the PSF. MCG can better characterize tangential anterior sources (with respect to the heart surface), while ECG excels with normally-oriented and posterior sources. Compared to either modality used alone, the sensitivity of combined ECG+MCG is less dependent on source orientation per source location, leading to better source estimates. Thus, for maximal sensitivity and optimal source estimation, the electric and magnetic measurements should be combined. (paper)

  16. Check your biosignals here: a new dataset for off-the-person ECG biometrics.

    Science.gov (United States)

    da Silva, Hugo Plácido; Lourenço, André; Fred, Ana; Raposo, Nuno; Aires-de-Sousa, Marta

    2014-02-01

    The Check Your Biosignals Here initiative (CYBHi) was developed as a way of creating a dataset and consistently repeatable acquisition framework, to further extend research in electrocardiographic (ECG) biometrics. In particular, our work targets the novel trend towards off-the-person data acquisition, which opens a broad new set of challenges and opportunities both for research and industry. While datasets with ECG signals collected using medical grade equipment at the chest can be easily found, for off-the-person ECG data the solution is generally for each team to collect their own corpus at considerable expense of resources. In this paper we describe the context, experimental considerations, methods, and preliminary findings of two public datasets created by our team, one for short-term and another for long-term assessment, with ECG data collected at the hand palms and fingers. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Conditional Random Fields for Morphological Analysis of Wireless ECG Signals

    Science.gov (United States)

    Natarajan, Annamalai; Gaiser, Edward; Angarita, Gustavo; Malison, Robert; Ganesan, Deepak; Marlin, Benjamin

    2015-01-01

    Thanks to advances in mobile sensing technologies, it has recently become practical to deploy wireless electrocardiograph sensors for continuous recording of ECG signals. This capability has diverse applications in the study of human health and behavior, but to realize its full potential, new computational tools are required to effectively deal with the uncertainty that results from the noisy and highly non-stationary signals collected using these devices. In this work, we present a novel approach to the problem of extracting the morphological structure of ECG signals based on the use of dynamically structured conditional random field (CRF) models. We apply this framework to the problem of extracting morphological structure from wireless ECG sensor data collected in a lab-based study of habituated cocaine users. Our results show that the proposed CRF-based approach significantly out-performs independent prediction models using the same features, as well as a widely cited open source toolkit. PMID:26726321

  18. Hazardous situation in the MR bore: induction in ECG leads causes fire

    International Nuclear Information System (INIS)

    Kugel, Harald; Bremer, Christoph; Fischbach, Roman; Lenzen, Horst; Tombach, Bernd; Heindel, Walter; Pueschel, Marco; Aken, Hugo van

    2003-01-01

    There is a potential hazard during examinations of patients with attached or implanted long conductors, e.g. ECG leads: an MR exam of the lumbar spine of a patient was performed in a 1.5-T scanner under ECG monitoring using equipment marked as MR compatible. Standard cabling of 370-cm length was guided without loops from the electrodes through the caudal opening of the magnet bore. During a sagittal T1-weighted turbo-spin-echo scan suddenly a flame of approximately 3 cm arose from the patient's shirt, close to the position of the electrodes. The supervising anaesthesiologist extinguished the flames with his hands. A subsequent physical examination revealed second- to third-degree burns. The analysis of the incident revealed that high voltages can be induced in straight conductors without loops as ECG cables by coupling with the electric component of the HF field. Local heating or sparking can cause an open flame at the position of the electrodes. This danger exists even with ECG equipment that is specifically marked as MR compatible. (orig.)

  19. Association between use of pre-hospital ECG and 30-day mortality: A large cohort study of patients experiencing chest pain.

    Science.gov (United States)

    Rawshani, Nina; Rawshani, Araz; Gelang, Carita; Herlitz, Johan; Bång, Angela; Andersson, Jan-Otto; Gellerstedt, Martin

    2017-12-01

    In the assessment of patients with chest pain, there is support for the use of pre-hospital ECG in the literature and in the care guidelines. Using propensity score methods, we aim to examine whether the mere acquisition of a pre-hospital ECG among patients with chest pain affects the outcome (30-day mortality). The association between pre-hospital ECG and 30-day mortality was studied in the overall cohort (n=13151), as well as in the one-to-one matched cohort with 2524 patients not examined with pre-hospital ECG and 2524 patients examined with pre-hospital ECG. In the overall cohort, 21% (n=2809) did not undergo an ECG tracing in the pre-hospital setting. Among those who had pain during transport, 14% (n=1159) did not undergo a pre-hospital ECG while 32% (n=1135) of those who did not have pain underwent an ECG tracing. In the overall cohort, the OR for 30-day mortality in patients who had a pre-hospital ECG, as compared with those who did not, was 0.63 (95% CI 0.05-0.79; pECG was used. The PH-ECG is underused among patients with chest discomfort and the mere acquisition of a pre-hospital ECG may reduce mortality. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Fusion of ECG and ABP signals based on wavelet transform for cardiac arrhythmias classification.

    Science.gov (United States)

    Arvanaghi, Roghayyeh; Daneshvar, Sabalan; Seyedarabi, Hadi; Goshvarpour, Atefeh

    2017-11-01

    Each of Electrocardiogram (ECG) and Atrial Blood Pressure (ABP) signals contain information of cardiac status. This information can be used for diagnosis and monitoring of diseases. The majority of previously proposed methods rely only on ECG signal to classify heart rhythms. In this paper, ECG and ABP were used to classify five different types of heart rhythms. To this end, two mentioned signals (ECG and ABP) have been fused. These physiological signals have been used from MINIC physioNet database. ECG and ABP signals have been fused together on the basis of the proposed Discrete Wavelet Transformation fusion technique. Then, some frequency features were extracted from the fused signal. To classify the different types of cardiac arrhythmias, these features were given to a multi-layer perceptron neural network. In this study, the best results for the proposed fusion algorithm were obtained. In this case, the accuracy rates of 96.6%, 96.9%, 95.6% and 93.9% were achieved for two, three, four and five classes, respectively. However, the maximum classification rate of 89% was obtained for two classes on the basis of ECG features. It has been found that the higher accuracy rates were acquired by using the proposed fusion technique. The results confirmed the importance of fusing features from different physiological signals to gain more accurate assessments. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Efficient ECG Signal Compression Using Adaptive Heart Model

    National Research Council Canada - National Science Library

    Szilagyi, S

    2001-01-01

    This paper presents an adaptive, heart-model-based electrocardiography (ECG) compression method. After conventional pre-filtering the waves from the signal are localized and the model's parameters are determined...

  2. Analysis Spectrum of ECG Signal and QRS Detection during Running on Treadmill

    Science.gov (United States)

    Agung Suhendra, M.; Ilham R., M.; Simbolon, Artha I.; Faizal A., M.; Munandar, A.

    2018-03-01

    The heart is an important organ in our metabolism in which it controls circulatory and oxygen. The heart exercise is needed one of them using the treadmill to prevent health. To analysis, it using electrocardiograph (ECG) to investigating and diagnosing anomalies of the heart. In this paper, we would like to analysis ECG signals during running on the treadmill with kinds of speeds. There are two analysis ECG signals i.e. QRS detection and power spectrum density (PSD). The result of PSD showed that subject 3 has highly for all subject and the result of QRS detection using pan Tomkins algorithm that a percentage of failed detection is an approaching to 0 % for all subject.

  3. Improving Door-to-balloon Time by Decreasing Door-to-ECG time for Walk-in STEMI Patients

    Directory of Open Access Journals (Sweden)

    Coyne, Christopher J.

    2014-12-01

    Full Text Available Introduction: The American Heart Association/American College of Cardiology guidelines recommend rapid door-to-electrocardiography (ECG times for patients with ST-segment elevation myocardial infarction (STEMI. Previous quality improvement research at our institution revealed that we were not meeting this benchmark for walk-in STEMI patients. The objective is to investigate whether simple, directed changes in the emergency department (ED triage process for potential cardiac patients could decrease door-to-ECG times and secondarily door-to-balloon times. Methods: We conducted an interventional study at a large, urban, public teaching hospital from April 2010 to June 2012. All patients who walked into the ED with a confirmed STEMI were enrolled in the study. The primary intervention involved creating a chief complaint-based “cardiac triage” designation that streamlined the evaluation of potential cardiac patients. A secondary intervention involved moving our ECG technician and ECG station to our initial triage area. The primary outcome measure was door-to-ECG time and the secondary outcome measure was door-to-balloon time. Results: We enrolled 91 walk-in STEMI patients prior to the intervention period and 141 patients after the invention. We observed statistically significant reductions in door-to-ECG time (43±93 to 30±72 minutes, median 23 to 14 minutes p<0.01, ECG-to-activation time (87±134 to 52±82 minutes, median 43 to 31 minutes p<0.01, and door-to-balloon time (134±146 to 84±40 minutes, median 85 -75 minutes p=0.03. Conclusion: By creating a chief complaint-based cardiac triage protocol and by streamlining ECG completion, walk-in STEMI patients are systematically processed through the ED. This is not only associated with a decrease in door-to-balloon time, but also a decrease in the variability of the time sensitive intervals of door-to-ECG and ECG-to-balloon time. [West J Emerg Med. 2015;16(1:184–189.

  4. Transform Domain Robust Variable Step Size Griffiths' Adaptive Algorithm for Noise Cancellation in ECG

    Science.gov (United States)

    Hegde, Veena; Deekshit, Ravishankar; Satyanarayana, P. S.

    2011-12-01

    The electrocardiogram (ECG) is widely used for diagnosis of heart diseases. Good quality of ECG is utilized by physicians for interpretation and identification of physiological and pathological phenomena. However, in real situations, ECG recordings are often corrupted by artifacts or noise. Noise severely limits the utility of the recorded ECG and thus needs to be removed, for better clinical evaluation. In the present paper a new noise cancellation technique is proposed for removal of random noise like muscle artifact from ECG signal. A transform domain robust variable step size Griffiths' LMS algorithm (TVGLMS) is proposed for noise cancellation. For the TVGLMS, the robust variable step size has been achieved by using the Griffiths' gradient which uses cross-correlation between the desired signal contaminated with observation or random noise and the input. The algorithm is discrete cosine transform (DCT) based and uses symmetric property of the signal to represent the signal in frequency domain with lesser number of frequency coefficients when compared to that of discrete Fourier transform (DFT). The algorithm is implemented for adaptive line enhancer (ALE) filter which extracts the ECG signal in a noisy environment using LMS filter adaptation. The proposed algorithm is found to have better convergence error/misadjustment when compared to that of ordinary transform domain LMS (TLMS) algorithm, both in the presence of white/colored observation noise. The reduction in convergence error achieved by the new algorithm with desired signal decomposition is found to be lower than that obtained without decomposition. The experimental results indicate that the proposed method is better than traditional adaptive filter using LMS algorithm in the aspects of retaining geometrical characteristics of ECG signal.

  5. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl [Sahlgrenska University Hospital, Department of Radiology, Gothenburg (Sweden); Perrotta, Sossio [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); Bech-Hanssen, Odd [Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Cardiology, Gothenburg (Sweden); Olaison, Lars [Sahlgrenska University Hospital, Department of Infectious Diseases, Gothenburg (Sweden); Svensson, Gunnar [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); The Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Institute of Medicine, Gothenburg (Sweden)

    2012-11-15

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  6. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    International Nuclear Information System (INIS)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl; Perrotta, Sossio; Bech-Hanssen, Odd; Olaison, Lars; Svensson, Gunnar

    2012-01-01

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  7. ECG Denoising Using Marginalized Particle Extended Kalman Filter With an Automatic Particle Weighting Strategy.

    Science.gov (United States)

    Hesar, Hamed Danandeh; Mohebbi, Maryam

    2017-05-01

    In this paper, a model-based Bayesian filtering framework called the "marginalized particle-extended Kalman filter (MP-EKF) algorithm" is proposed for electrocardiogram (ECG) denoising. This algorithm does not have the extended Kalman filter (EKF) shortcoming in handling non-Gaussian nonstationary situations because of its nonlinear framework. In addition, it has less computational complexity compared with particle filter. This filter improves ECG denoising performance by implementing marginalized particle filter framework while reducing its computational complexity using EKF framework. An automatic particle weighting strategy is also proposed here that controls the reliance of our framework to the acquired measurements. We evaluated the proposed filter on several normal ECGs selected from MIT-BIH normal sinus rhythm database. To do so, artificial white Gaussian and colored noises as well as nonstationary real muscle artifact (MA) noise over a range of low SNRs from 10 to -5 dB were added to these normal ECG segments. The benchmark methods were the EKF and extended Kalman smoother (EKS) algorithms which are the first model-based Bayesian algorithms introduced in the field of ECG denoising. From SNR viewpoint, the experiments showed that in the presence of Gaussian white noise, the proposed framework outperforms the EKF and EKS algorithms in lower input SNRs where the measurements and state model are not reliable. Owing to its nonlinear framework and particle weighting strategy, the proposed algorithm attained better results at all input SNRs in non-Gaussian nonstationary situations (such as presence of pink noise, brown noise, and real MA). In addition, the impact of the proposed filtering method on the distortion of diagnostic features of the ECG was investigated and compared with EKF/EKS methods using an ECG diagnostic distortion measure called the "Multi-Scale Entropy Based Weighted Distortion Measure" or MSEWPRD. The results revealed that our proposed

  8. E-Bra system for women ECG measurement with GPRS communication, Nanosensor, and motion artifact remove algorithm

    Science.gov (United States)

    Kwon, Hyeokjun; Oh, Sechang; Kumar, Prashanth S.; Varadan, Vijay K.

    2012-10-01

    CardioVascular Disease(CVD)s lead the sudden cardiac death due to irregular phenomenon of the cardiac signal by the abnormal case of blood vessel and cardiac structure. For last two decades, cardiac disease research for man is under active discussion. As a result, the death rate by cardiac disease in men has been falling gradually compared with relatively increasing the women death rate due to CVD[2]. The main reason of this phenomenon causes the lack a sense of the seriousness to female CVD and different symptom of female CVD compared with the symptoms of male CVD. Usually, because the women CVD accompanies with ordinary symptoms unrecognizing the heart abnormality signal such as unusual fatigue, sleep disturbances, shortness of breath, anxiety, chest discomfort, and indigestion dyspepsia, most women CVD patients do not realize that these symptoms are related to the CVD symptoms. Therefore, periodic ECG signal observation is required for women cardiac disease patients. ElectroCardioGram(ECG) detection, treadmill test/exercise ECG, nuclear scan, coronary angiography, and intracoronary ultrasound are used to diagnose abnormality of heart. Among the medical checkup methods for CVDs checkup, it is very effective method for the diagnosis of cardiac disease and the early detection of heart abnormality to monitor ECG periodically. This paper suggests the effective ECG monitoring system for woman by attaching the system on woman's brassiere by using augmented chest lead attachment method. The suggested system in this paper consists of ECG signal transmission system and a server program to display and analyze the transmitted ECG. The ECG signal transmission system consists of three parts such as ECG physical signal detection part with two electrodes made by gold nanowire structure, data acquisition with AD converter, and data transmission part with GPRS(General Packet Radio Service) communication. Usually, to detect human bio signal, Ag/AgCl or gold cup electrodes are used

  9. ECG Changes In Patients On Chronic Psychotropic medication

    African Journals Online (AJOL)

    2006-08-31

    Aug 31, 2006 ... The use of psychotropic drugs is associated with. ECG changes in ... impact, while the secondary tricyclic antidepressants (nortriptyline, desipramine) ... Human Research Ethics Committee approved the study. Procedures.

  10. Position difference regularity of corresponding R-wave peaks for maternal ECG components from different abdominal points

    International Nuclear Information System (INIS)

    Zhang Jie-Min; Liu Hong-Xing; Huang Xiao-Lin; Si Jun-Feng; Guan Qun; Tang Li-Ming; Liu Tie-Bing

    2014-01-01

    We collected 343 groups of abdominal electrocardiogram (ECG) data from 78 pregnant women and deleted the channels unable for experts to determine R-wave peaks from them; then, based on these filtered data, the statistics of position difference of corresponding R-wave peaks for different maternal ECG components from different points were studied. The resultant statistics showed the regularity that the position difference of corresponding maternal R-wave peaks between different abdominal points does not exceed the range of 30 ms. The regularity was also proved using the fECG data from MIT—BIH PhysioBank. Additionally, the paper applied the obtained regularity, the range of position differences of the corresponding maternal R-wave peaks, to accomplish the automatic detection of maternal R-wave peaks in the recorded all initial 343 groups of abdominal signals, including the ones with the largest fetal ECG components, and all 55 groups of ECG data from MIT—BIH PhysioBank, achieving the successful separation of the maternal ECGs. (interdisciplinary physics and related areas of science and technology)

  11. A wavelet-based ECG delineation algorithm for 32-bit integer online processing.

    Science.gov (United States)

    Di Marco, Luigi Y; Chiari, Lorenzo

    2011-04-03

    Since the first well-known electrocardiogram (ECG) delineator based on Wavelet Transform (WT) presented by Li et al. in 1995, a significant research effort has been devoted to the exploitation of this promising method. Its ability to reliably delineate the major waveform components (mono- or bi-phasic P wave, QRS, and mono- or bi-phasic T wave) would make it a suitable candidate for efficient online processing of ambulatory ECG signals. Unfortunately, previous implementations of this method adopt non-linear operators such as root mean square (RMS) or floating point algebra, which are computationally demanding. This paper presents a 32-bit integer, linear algebra advanced approach to online QRS detection and P-QRS-T waves delineation of a single lead ECG signal, based on WT. The QRS detector performance was validated on the MIT-BIH Arrhythmia Database (sensitivity Se = 99.77%, positive predictive value P+ = 99.86%, on 109010 annotated beats) and on the European ST-T Database (Se = 99.81%, P+ = 99.56%, on 788050 annotated beats). The ECG delineator was validated on the QT Database, showing a mean error between manual and automatic annotation below 1.5 samples for all fiducial points: P-onset, P-peak, P-offset, QRS-onset, QRS-offset, T-peak, T-offset, and a mean standard deviation comparable to other established methods. The proposed algorithm exhibits reliable QRS detection as well as accurate ECG delineation, in spite of a simple structure built on integer linear algebra.

  12. Wearable technology and ECG processing for fall risk assessment, prevention and detection.

    Science.gov (United States)

    Melillo, Paolo; Castaldo, Rossana; Sannino, Giovanna; Orrico, Ada; de Pietro, Giuseppe; Pecchia, Leandro

    2015-01-01

    Falls represent one of the most common causes of injury-related morbidity and mortality in later life. Subjects with cardiovascular disorders (e.g., related to autonomic dysfunctions and postural hypotension) are at higher risk of falling. Autonomic dysfunctions increasing the risk of falling in the short and mid-term could be assessed by Heart Rate Variability (HRV) extracted by electrocardiograph (ECG). We developed three trials for assessing the usefulness of ECG monitoring using wearable devices for: risk assessment of falling in the next few weeks; prevention of imminent falls due to standing hypotension; and fall detection. Statistical and data-mining methods are adopted to develop classification and regression models, validated with the cross-validation approach. The first classifier based on HRV features enabled to identify future fallers among hypertensive patients with an accuracy of 72% (sensitivity: 51.1%, specificity: 80.2%). The regression model to predict falls due to orthostatic dropdown from HRV recorded before standing achieved an overall accuracy of 80% (sensitivity: 92%, specificity: 90%). Finally, the classifier to detect simulated falls using ECG achieved an accuracy of 77.3% (sensitivity: 81.8%, specificity: 72.7%). The evidence from these three studies showed that ECG monitoring and processing could achieve satisfactory performances compared to other system for risk assessment, fall prevention and detection. This is interesting as differently from other technologies actually employed to prevent falls, ECG is recommended for many other pathologies of later life and is more accepted by senior citizens.

  13. Modeling of hydroecological feedbacks predicts distinct classes of landscape pattern, process, and restoration potential in shallow aquatic ecosystems

    Science.gov (United States)

    Larsen, Laurel G.; Harvey, Judson W.

    2011-01-01

    It is widely recognized that interactions between vegetation and flow cause the emergence of channel patterns that are distinct from the standard Schumm classification of river channels. Although landscape pattern is known to be linked to ecosystem services such as habitat provision, pollutant removal, and sustaining biodiversity, the mechanisms responsible for the development and stability of different landscape patterns in shallow, vegetated flows have remained poorly understood. Fortunately, recent advances have made possible large-scale models of flow through vegetated environments that can be run over a range of environmental variables and over timescales of millennia. We describe a new, quasi-3D cellular automata model that couples simulations of shallow-water flow, bed shear stresses, sediment transport, and vegetation dynamics in an efficient manner. That efficiency allowed us to apply the model widely in order to determine how different hydroecological feedbacks control landscape pattern and process in various types of wetlands and floodplains. Distinct classes of landscape pattern were uniquely associated with specific types of allogenic and autogenic drivers in wetland flows. Regular, anisotropically patterned wetlands were dominated by allogenic processes (i.e., processes driven by periodic high water levels and flow velocities that redistribute sediment), relative to autogenic processes (e.g., vegetation production, peat accretion, and gravitational erosion). These anistropically patterned wetlands are therefore particularly prone to hydrologic disturbance. Other classes of wetlands that emerged from simulated interactions included maze-patterned, amorphous, and topographically noisy marshes, open marsh with islands, banded string-pool sequences perpendicular to flow, parallel deep and narrow channels flanked by marsh, and ridge-and-slough patterned marsh oriented parallel to flow. Because vegetation both affects and responds to the balance between the

  14. Comparison of JADE and canonical correlation analysis for ECG de-noising.

    Science.gov (United States)

    Kuzilek, Jakub; Kremen, Vaclav; Lhotska, Lenka

    2014-01-01

    This paper explores differences between two methods for blind source separation within frame of ECG de-noising. First method is joint approximate diagonalization of eigenmatrices, which is based on estimation of fourth order cross-cummulant tensor and its diagonalization. Second one is the statistical method known as canonical correlation analysis, which is based on estimation of correlation matrices between two multidimensional variables. Both methods were used within method, which combines the blind source separation algorithm with decision tree. The evaluation was made on large database of 382 long-term ECG signals and the results were examined. Biggest difference was found in results of 50 Hz power line interference where the CCA algorithm completely failed. Thus main power of CCA lies in estimation of unstructured noise within ECG. JADE algorithm has larger computational complexity thus the CCA perfomed faster when estimating the components.

  15. The ECG vertigo in diabetes and cardiac autonomic neuropathy.

    Science.gov (United States)

    Voulgari, Christina; Tentolouris, Nicholas; Stefanadis, Christodoulos

    2011-01-01

    The importance of diabetes in the epidemiology of cardiovascular diseases cannot be overemphasized. About one third of acute myocardial infarction patients have diabetes, and its prevalence is steadily increasing. The decrease in cardiac mortality in people with diabetes is lagging behind that of the general population. Cardiovascular disease is a broad term which includes any condition causing pathological changes in blood vessels, cardiac muscle or valves, and cardiac rhythm. The ECG offers a quick, noninvasive clinical and research screen for the early detection of cardiovascular disease in diabetes. In this paper, the clinical and research value of the ECG is readdressed in diabetes and in the presence of cardiac autonomic neuropathy.

  16. Prolonged corrected QT interval is predictive of future stroke events even in subjects without ECG-diagnosed left ventricular hypertrophy.

    Science.gov (United States)

    Ishikawa, Joji; Ishikawa, Shizukiyo; Kario, Kazuomi

    2015-03-01

    We attempted to evaluate whether subjects who exhibit prolonged corrected QT (QTc) interval (≥440 ms in men and ≥460 ms in women) on ECG, with and without ECG-diagnosed left ventricular hypertrophy (ECG-LVH; Cornell product, ≥244 mV×ms), are at increased risk of stroke. Among the 10 643 subjects, there were a total of 375 stroke events during the follow-up period (128.7±28.1 months; 114 142 person-years). The subjects with prolonged QTc interval (hazard ratio, 2.13; 95% confidence interval, 1.22-3.73) had an increased risk of stroke even after adjustment for ECG-LVH (hazard ratio, 1.71; 95% confidence interval, 1.22-2.40). When we stratified the subjects into those with neither a prolonged QTc interval nor ECG-LVH, those with a prolonged QTc interval but without ECG-LVH, and those with ECG-LVH, multivariate-adjusted Cox proportional hazards analysis demonstrated that the subjects with prolonged QTc intervals but not ECG-LVH (1.2% of all subjects; incidence, 10.7%; hazard ratio, 2.70, 95% confidence interval, 1.48-4.94) and those with ECG-LVH (incidence, 7.9%; hazard ratio, 1.83; 95% confidence interval, 1.31-2.57) had an increased risk of stroke events, compared with those with neither a prolonged QTc interval nor ECG-LVH. In conclusion, prolonged QTc interval was associated with stroke risk even among patients without ECG-LVH in the general population. © 2014 American Heart Association, Inc.

  17. Threshold Research on Highway Length under Typical Landscape Patterns Based on Drivers’ Physiological Performance

    Directory of Open Access Journals (Sweden)

    Xia Zhao

    2015-01-01

    Full Text Available The appropriately landscaped highway scenes may not only help improve road safety and comfort but also help protect ecological environment. Yet there is very little research data on highway length threshold with consideration of distinctive landscape patterns. Against this backdrop, the paper aims to quantitatively analyze highway landscape’s effect on driving behavior based on drivers’ physiological performance and quantify highway length thresholds under three typical landscape patterns, namely, “open,” “semiopen,” and “vertical” ones. The statistical analysis was based on data collected in a driving simulator and electrocardiograph. Specifically, vehicle-related data, ECG data, and supplemental subjective stress perception were collected. The study extracted two characteristic indices, lane deviation and LF/HF, and extrapolated the drivers’ U-shaped physiological response to landscape patterns. Models on highway length were built based on LF/HF’s variation trend with highway length. The results revealed that the theoretical highway length threshold tended to increase when the landscape pattern was switched to open, semiopen, and vertical ones. And the reliability and accuracy of the results were validated by questionnaires and field operational tests. Findings from this research will assist practitioners in taking active environmental countermeasures pertaining to different roadside landscape patterns.

  18. On the application of optimal wavelet filter banks for ECG signal classification

    International Nuclear Information System (INIS)

    Hadjiloucas, S; Jannah, N; Hwang, F; Galvão, R K H

    2014-01-01

    This paper discusses ECG signal classification after parametrizing the ECG waveforms in the wavelet domain. Signal decomposition using perfect reconstruction quadrature mirror filter banks can provide a very parsimonious representation of ECG signals. In the current work, the filter parameters are adjusted by a numerical optimization algorithm in order to minimize a cost function associated to the filter cut-off sharpness. The goal consists of achieving a better compromise between frequency selectivity and time resolution at each decomposition level than standard orthogonal filter banks such as those of the Daubechies and Coiflet families. Our aim is to optimally decompose the signals in the wavelet domain so that they can be subsequently used as inputs for training to a neural network classifier

  19. An Investigation on the Effect of Extremely Low Frequency Pulsed Electromagnetic Fields on Human Electrocardiograms (ECGs).

    Science.gov (United States)

    Fang, Qiang; Mahmoud, Seedahmed S; Yan, Jiayong; Li, Hui

    2016-11-23

    For this investigation, we studied the effects of extremely low frequency pulse electromagnetic fields (ELF-PEMF) on the human cardiac signal. Electrocardiograms (ECGs) of 22 healthy volunteers before and after a short duration of ELF-PEMF exposure were recorded. The experiment was conducted under single-blind conditions. The root mean square (RMS) value of the recorded data was considered as comparison criteria. We also measured and analysed four important ECG time intervals before and after ELF-PEMF exposure. Results revealed that the RMS value of the ECG recordings from 18 participants (81.8% of the total participants) increased with a mean value of 3.72%. The increase in ECG voltage levels was then verified by a second experimental protocol with a control exposure. In addition to this, we used hyperbolic T-distributions (HTD) in the analysis of ECG signals to verify the change in the RR interval. It was found that there were small shifts in the frequency-domain signal before and after EMF exposure. This shift has an influence on all frequency components of the ECG signals, as all spectrums were shifted. It is shown from this investigation that a short time exposure to ELF-PEMF can affect the properties of ECG signals. Further study is needed to consolidate this finding and discover more on the biological effects of ELF-PEMF on human physiological processes.

  20. Clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease

    International Nuclear Information System (INIS)

    Tian Xinhua; Liu Jianhua; Gong Tingting; Geng Lili; Sun Yong

    2011-01-01

    Objective: To investigate the clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease, and to evaluate the relationship of the image quality and radiation dose between prospective ECG-gated and retrospective ECG-gated cardiac CT angiography (CTA). Methods: Sixty patients who doubt congenital heart disease underwent cardiac CTA, and they were randomly divided into two groups. Thirty patients in group A underwent prospective ECG-gated cardiac CTA, and thirty patients in group B underwent retrospective ECG-gated cardiac CTA. Then the homogeneous enhancement of vascular structures, stair-step artifact, overall image quality and radiation dose were evaluated. Results: The homogeneous enhancement of vascular structures were 2.8±0.3 and 2.7±0.6, respectively, in two groups; and there was no statistical significance (P>0.05). The stair-step artifact were 3.0±0.9 and 3.1±0.9, respectively, in two groups; and there was also no statistical significance (P>0.05). The overall image quality were 3.0±0.8 and 3.1±0.9, respectively, in two group; and there was statistical significance (P>0.05). However, the effective dose were (5.24±0.52) mSv and (16.68±1.49) mSv, respectively, in two groups; and there was statistical significance (P<0.001). Conclusion: Compared with retrospective ECG-gated cardiac CTA, prospective ECG-gated cardiac CTA can reduce radiation dose about 68.6% , while maintaining the image quality which could be made diagnosis. (authors)

  1. Are ECG monitoring recommendations before prescription of QT-prolonging drugs applied in daily practice?

    DEFF Research Database (Denmark)

    Warnier, Miriam Jacoba; Rutten, Frans Hendrik; Souverein, Patrick Cyriel

    2015-01-01

    PURPOSE: Monitoring of the QT duration by electrocardiography (ECG) prior to treatment is frequently recommended in the label of QT-prolonging drugs. It is, however, unknown how often general practitioners in daily clinical practice are adhering to these risk-minimization measures. We assessed...... the frequency of ECG measurements in patients where haloperidol was initiated in primary care. METHODS: Patients (≥18 years) with a first prescription of haloperidol in the UK Clinical Practice Research Datalink (2009-2013) were included. The proportion of ECGs made was determined in two blocks of 4 weeks......: during the exposure period when haloperidol was initiated, and during the control period, 1 year before. Conditional logistic regression analysis was applied to calculate the relative risk of having an ECG in the exposure period compared with the control period. Subgroup analyses were performed to assess...

  2. Distinct pattern of TP53 mutations in human immunodeficiency virus-related head and neck squamous cell carcinoma.

    Science.gov (United States)

    Gleber-Netto, Frederico O; Zhao, Mei; Trivedi, Sanchit; Wang, Jiping; Jasser, Samar; McDowell, Christina; Kadara, Humam; Zhang, Jiexin; Wang, Jing; William, William N; Lee, J Jack; Nguyen, Minh Ly; Pai, Sara I; Walline, Heather M; Shin, Dong M; Ferris, Robert L; Carey, Thomas E; Myers, Jeffrey N; Pickering, Curtis R

    2018-01-01

    Human immunodeficiency virus-infected individuals (HIVIIs) have a higher incidence of head and neck squamous cell carcinoma (HNSCC), and clinical and histopathological differences have been observed in their tumors in comparison with those of HNSCC patients without a human immunodeficiency virus (HIV) infection. The reasons for these differences are not clear, and molecular differences between HIV-related HNSCC and non-HIV-related HNSCC may exist. This study compared the mutational patterns of HIV-related HNSCC and non-HIV-related HNSCC. The DNA of 20 samples of HIV-related HNSCCs and 32 samples of non-HIV-related HNSCCs was sequenced. DNA libraries covering exons of 18 genes frequently mutated in HNSCC (AJUBA, CASP8, CCND1, CDKN2A, EGFR, FAT1, FBXW7, HLA-A, HRAS, KEAP1, NFE2L2, NOTCH1, NOTCH2, NSD1, PIK3CA, TGFBR2, TP53, and TP63) were prepared and sequenced on an Ion Personal Genome Machine sequencer. DNA sequencing data were analyzed with Ion Reporter software. The human papillomavirus (HPV) status of the tumor samples was assessed with in situ hybridization, the MassARRAY HPV multiplex polymerase chain reaction assay, and p16 immunostaining. Mutation calls were compared among the studied groups. HIV-related HNSCC revealed a distinct pattern of mutations in comparison with non-HIV-related HNSCC. TP53 mutation frequencies were significantly lower in HIV-related HNSCC. Mutations in HIV+ patients tended to be TpC>T nucleotide changes for all mutated genes but especially for TP53. HNSCC in HIVIIs presents a distinct pattern of genetic mutations, particularly in the TP53 gene. HIV-related HNSCC may have a distinct biology, and an effect of the HIV virus on the pathogenesis of these tumors should not be ruled out. Cancer 2018;124:84-94. © 2017 American Cancer Society. © 2017 American Cancer Society.

  3. ECG contamination of EEG signals: effect on entropy.

    Science.gov (United States)

    Chakrabarti, Dhritiman; Bansal, Sonia

    2016-02-01

    Entropy™ is a proprietary algorithm which uses spectral entropy analysis of electroencephalographic (EEG) signals to produce indices which are used as a measure of depth of hypnosis. We describe a report of electrocardiographic (ECG) contamination of EEG signals leading to fluctuating erroneous Entropy values. An explanation is provided for mechanism behind this observation by describing the spread of ECG signals in head and neck and its influence on EEG/Entropy by correlating the observation with the published Entropy algorithm. While the Entropy algorithm has been well conceived, there are still instances in which it can produce erroneous values. Such erroneous values and their cause may be identified by close scrutiny of the EEG waveform if Entropy values seem out of sync with that expected at given anaesthetic levels.

  4. Intelligent classification of electrocardiogram (ECG) signal using extended Kalman Filter (EKF) based neuro fuzzy system.

    Science.gov (United States)

    Meau, Yeong Pong; Ibrahim, Fatimah; Narainasamy, Selvanathan A L; Omar, Razali

    2006-05-01

    This study presents the development of a hybrid system consisting of an ensemble of Extended Kalman Filter (EKF) based Multi Layer Perceptron Network (MLPN) and a one-pass learning Fuzzy Inference System using Look-up Table Scheme for the recognition of electrocardiogram (ECG) signals. This system can distinguish various types of abnormal ECG signals such as Ventricular Premature Cycle (VPC), T wave inversion (TINV), ST segment depression (STDP), and Supraventricular Tachycardia (SVT) from normal sinus rhythm (NSR) ECG signal.

  5. Bayesian Classification Models for Premature Ventricular Contraction Detection on ECG Traces.

    Science.gov (United States)

    Casas, Manuel M; Avitia, Roberto L; Gonzalez-Navarro, Felix F; Cardenas-Haro, Jose A; Reyna, Marco A

    2018-01-01

    According to the American Heart Association, in its latest commission about Ventricular Arrhythmias and Sudden Death 2006, the epidemiology of the ventricular arrhythmias ranges from a series of risk descriptors and clinical markers that go from ventricular premature complexes and nonsustained ventricular tachycardia to sudden cardiac death due to ventricular tachycardia in patients with or without clinical history. The premature ventricular complexes (PVCs) are known to be associated with malignant ventricular arrhythmias and sudden cardiac death (SCD) cases. Detecting this kind of arrhythmia has been crucial in clinical applications. The electrocardiogram (ECG) is a clinical test used to measure the heart electrical activity for inferences and diagnosis. Analyzing large ECG traces from several thousands of beats has brought the necessity to develop mathematical models that can automatically make assumptions about the heart condition. In this work, 80 different features from 108,653 ECG classified beats of the gold-standard MIT-BIH database were extracted in order to classify the Normal, PVC, and other kind of ECG beats. Three well-known Bayesian classification algorithms were trained and tested using these extracted features. Experimental results show that the F1 scores for each class were above 0.95, giving almost the perfect value for the PVC class. This gave us a promising path in the development of automated mechanisms for the detection of PVC complexes.

  6. On the resolution of ECG acquisition systems for the reliable analysis of the P-wave

    International Nuclear Information System (INIS)

    Censi, Federica; Calcagnini, Giovanni; Mattei, Eugenio; Triventi, Michele; Bartolini, Pietro; Corazza, Ivan; Boriani, Giuseppe

    2012-01-01

    The analysis of the P-wave on surface ECG is widely used to assess the risk of atrial arrhythmias. In order to provide reliable results, the automatic analysis of the P-wave must be precise and reliable and must take into account technical aspects, one of those being the resolution of the acquisition system. The aim of this note is to investigate the effects of the amplitude resolution of ECG acquisition systems on the P-wave analysis. Starting from ECG recorded by an acquisition system with a less significant bit (LSB) of 31 nV (24 bit on an input range of 524 mVpp), we reproduced an ECG signal as acquired by systems with lower resolution (16, 15, 14, 13 and 12 bit). We found that, when the LSB is of the order of 128 µV (12 bit), a single P-wave is not recognizable on ECG. However, when averaging is applied, a P-wave template can be extracted, apparently suitable for the P-wave analysis. Results obtained in terms of P-wave duration and morphology revealed that the analysis of ECG at lowest resolutions (from 12 to 14 bit, LSB higher than 30 µV) could lead to misleading results. However, the resolution used nowadays in modern electrocardiographs (15 and 16 bit, LSB <10 µV) is sufficient for the reliable analysis of the P-wave. (note)

  7. The effect of 50/60 Hz notch filter application on human and rat ECG recordings

    International Nuclear Information System (INIS)

    Vale-Cardoso, A S; Guimarães, H N

    2010-01-01

    Power-line interference is always present in indoor biopotential measurements, even when its extremely low magnitude makes it imperceptible. In special situations, this kind of interference can be neglected, but this is not a general rule. In laboratory experiments and clinical analysis, it is hard (and expensive) to isolate the subject of measurement from electrical fields produced by a power line. In human biopotential recordings, it is common practice to apply a 50/60 Hz notch filter to reduce this kind of interference. In such cases, there is no considerable distortion observed on the recorded signal. However, experiments showed that it is not true for rat ECG recordings. Several kinds of notch filters (analog and digital) were implemented for evaluation of the distortion caused on ECG signals. These filters were applied to ECGs of humans and rats and then distortion estimates were computed from their resulting signals. The comparison of these estimates showed that, as experimentally observed, rat ECG signals are significantly distorted and deformed when a 50/60 Hz notch filter is applied to them, while human ECGs are not. The major goal of this paper is to show that the use of a notch filter for power-line interference rejection, when applied to rat ECG recordings, can severely deform the QRS complex of such signals, warning researchers against its non-deliberate usage

  8. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    Science.gov (United States)

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the

  9. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals

    Directory of Open Access Journals (Sweden)

    Prasan Kumar Sahoo

    2018-01-01

    Full Text Available Cardiovascular disease (CVD is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI, computerized tomography scan (CT scan, and echocardiography (Echo are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL. In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to

  10. The ECG Vertigo in Diabetes and Cardiac Autonomic Neuropathy

    Directory of Open Access Journals (Sweden)

    Christina Voulgari

    2011-01-01

    Full Text Available The importance of diabetes in the epidemiology of cardiovascular diseases cannot be overemphasized. About one third of acute myocardial infarction patients have diabetes, and its prevalence is steadily increasing. The decrease in cardiac mortality in people with diabetes is lagging behind that of the general population. Cardiovascular disease is a broad term which includes any condition causing pathological changes in blood vessels, cardiac muscle or valves, and cardiac rhythm. The ECG offers a quick, noninvasive clinical and research screen for the early detection of cardiovascular disease in diabetes. In this paper, the clinical and research value of the ECG is readdressed in diabetes and in the presence of cardiac autonomic neuropathy.

  11. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Amale Ankhili

    2018-02-01

    Full Text Available A medical quality electrocardiogram (ECG signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate (PEDOT:PSS in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras, by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  12. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    Science.gov (United States)

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  13. Extracting the respiration cycle lengths from ECG signal recorded with bed sheet electrodes

    International Nuclear Information System (INIS)

    Vehkaoja, A; Peltokangas, M; Lekkala, J

    2013-01-01

    A method for recognizing the respiration cycle lengths from the electrocardiographic (ECG) signal recorded with textile electrodes that are attached to a bed sheet is proposed. The method uses two features extracted from the ECG that are affected by the respiration: respiratory sinus arrhythmia and the amplitude of the R-peaks. The proposed method was tested in one hour long recordings with ten healthy young adults. A relative mean absolute error of 5.6 % was achieved when the algorithm was able to provide a result for approximately 40 % of the time. 90 % of the values were within 0.5 s and 97 % within 1 s from the reference respiration value. In addition to the instantaneous respiration cycle lengths, also the mean values during 1 and 5 minutes epochs are calculated. The effect of the ECG signal source is evaluated by calculating the result also from the simultaneously recorded reference ECG signal. The acquired respiration information can be used in the estimation of sleep quality and the detection of sleep disorders

  14. Radiotherapy-induced Early ECG Changes and Their Comparison with Echocardiography in Patients with Early-stage Breast Cancer.

    Science.gov (United States)

    Tuohinen, Suvi Sirkku; Keski-Pukkila, Konsta; Skyttä, Tanja; Huhtala, Heini; Virtanen, Vesa; Kellokumpu-Lehtinen, Pirkko-Liisa; Raatikainen, Pekka; Nikus, Kjell

    2018-04-01

    Early electrocardiogram (ECG) changes after breast cancer radiotherapy (RT) have been reported, but their characteristics and associated factors are largely unknown. This study aimed to explore early RT-induced ECG changes and to compare them with echocardiography changes. Sixty eligible patients with chemotherapy-naïve left-sided and 20 with right-sided breast cancer were evaluated with echocardiography, blood samples and ECG before and after RT. RT-induced ECG changes in the anterior leads. T-Wave changes were most frequent. T-Wave decline was associated independently with patient age (β=-0.245, p=0.005), mean heart radiation dose (β=1.252, p=0.001) and global systolic strain rate change (β=7.943, p=0.002). T-Wave inversion was associated independently with mean heart radiation dose (β=0.143, pECG changes were prevalent and associated with functional and structural changes in echocardiography. ECG could be used for post-RT cardiac screening. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  15. Dry Electrode Harness System For Wireless 12-LEAD ECG

    Data.gov (United States)

    National Aeronautics and Space Administration — Human spaceflight requires the ability to obtain diagnostic quality 12-lead electrocardiograms (ECGs). Current systems require significant upmass, volume, and crew...

  16. Implementation of a wireless ECG acquisition SoC for IEEE 802.15.4 (ZigBee) applications.

    Science.gov (United States)

    Wang, Liang-Hung; Chen, Tsung-Yen; Lin, Kuang-Hao; Fang, Qiang; Lee, Shuenn-Yuh

    2015-01-01

    This paper presents a wireless biosignal acquisition system-on-a-chip (WBSA-SoC) specialized for electrocardiogram (ECG) monitoring. The proposed system consists of three subsystems, namely, 1) the ECG acquisition node, 2) the protocol for standard IEEE 802.15.4 ZigBee system, and 3) the RF transmitter circuits. The ZigBee protocol is adopted for wireless communication to achieve high integration, applicability, and portability. A fully integrated CMOS RF front end containing a quadrature voltage-controlled oscillator and a 2.4-GHz low-IF (i.e., zero-IF) transmitter is employed to transmit ECG signals through wireless communication. The low-power WBSA-SoC is implemented by the TSMC 0.18-μm standard CMOS process. An ARM-based displayer with FPGA demodulation and an RF receiver with analog-to-digital mixed-mode circuits are constructed as verification platform to demonstrate the wireless ECG acquisition system. Measurement results on the human body show that the proposed SoC can effectively acquire ECG signals.

  17. Value of the electrocardiogram in the diagnosis and prognosis of Brugada syndrome

    International Nuclear Information System (INIS)

    Perez-Riera, A; Femenia, F.; Baranchuk Facc, A

    2011-01-01

    Twelve-lead ECG associated to high right para sternal accessory leads is the resource that yields a greatest number of diagnostic and prognostic information in patients carriers of Brugada (Br S). By this simple, cheap, reproducible, and operator-independent method, depolarization alterations can be studied as well as ventricular re polarization aspects. The method allows diagnosing frequent episodes of atrial fibrillation and other supraventricular arrhythmias, as well as characterizing the different ventricular tachyarrhythmias. The analysis of the Frank VCG (F-VCG) of patients with Br S suggests the duality of the underlying pathophysiologic mechanisms of the Brugada Type-1 ECG pattern. F-VCG of patients with Brugada type-1 ECG pattern has distinctive characteristics from the F-VCG of individuals with R BBB pattern. The understanding of these mechanisms may help to guide future therapeutic efforts to control the channels dysfunction associated with this intriguing channelopaty

  18. Robust electrocardiogram (ECG) beat classification using discrete wavelet transform

    International Nuclear Information System (INIS)

    Minhas, Fayyaz-ul-Amir Afsar; Arif, Muhammad

    2008-01-01

    This paper presents a robust technique for the classification of six types of heartbeats through an electrocardiogram (ECG). Features extracted from the QRS complex of the ECG using a wavelet transform along with the instantaneous RR-interval are used for beat classification. The wavelet transform utilized for feature extraction in this paper can also be employed for QRS delineation, leading to reduction in overall system complexity as no separate feature extraction stage would be required in the practical implementation of the system. Only 11 features are used for beat classification with the classification accuracy of ∼99.5% through a KNN classifier. Another main advantage of this method is its robustness to noise, which is illustrated in this paper through experimental results. Furthermore, principal component analysis (PCA) has been used for feature reduction, which reduces the number of features from 11 to 6 while retaining the high beat classification accuracy. Due to reduction in computational complexity (using six features, the time required is ∼4 ms per beat), a simple classifier and noise robustness (at 10 dB signal-to-noise ratio, accuracy is 95%), this method offers substantial advantages over previous techniques for implementation in a practical ECG analyzer

  19. Study on a Biometric Authentication Model based on ECG using a Fuzzy Neural Network

    Science.gov (United States)

    Kim, Ho J.; Lim, Joon S.

    2018-03-01

    Traditional authentication methods use numbers or graphic passwords and thus involve the risk of loss or theft. Various studies are underway regarding biometric authentication because it uses the unique biometric data of a human being. Biometric authentication technology using ECG from biometric data involves signals that record electrical stimuli from the heart. It is difficult to manipulate and is advantageous in that it enables unrestrained measurements from sensors that are attached to the skin. This study is on biometric authentication methods using the neural network with weighted fuzzy membership functions (NEWFM). In the biometric authentication process, normalization and the ensemble average is applied during preprocessing, characteristics are extracted using Haar-wavelets, and a registration process called “training” is performed in the fuzzy neural network. In the experiment, biometric authentication was performed on 73 subjects in the Physionet Database. 10-40 ECG waveforms were tested for use in the registration process, and 15 ECG waveforms were deemed the appropriate number for registering ECG waveforms. 1 ECG waveforms were used during the authentication stage to conduct the biometric authentication test. Upon testing the proposed biometric authentication method based on 73 subjects from the Physionet Database, the TAR was 98.32% and FAR was 5.84%.

  20. Construction of a Resting High Fidelity ECG "SuperScore" for Management and Screening of Heart Disease

    Science.gov (United States)

    Schlegel, Todd T.; Delgado, Reynolds; Poulin, Greg; Starc, Vito; Arenare, Brian; Rahman, M. A.

    2006-01-01

    Resting conventional ECG is notoriously insensitive for detecting coronary artery disease (CAD) and only nominally useful in screening for cardiomyopathy (CM). Similarly, conventional exercise stress test ECG is both time- and labor-consuming and its accuracy in identifying CAD is suboptimal for use in population screening. We retrospectively investigated the accuracy of several advanced resting electrocardiographic (ECG) parameters, both alone and in combination, for detecting CAD and cardiomyopathy (CM).

  1. Educational technology improves ECG interpretation of acute myocardial infarction among medical students and emergency medicine residents.

    Science.gov (United States)

    Pourmand, Ali; Tanski, Mary; Davis, Steven; Shokoohi, Hamid; Lucas, Raymond; Zaver, Fareen

    2015-01-01

    Asynchronous online training has become an increasingly popular educational format in the new era of technology-based professional development. We sought to evaluate the impact of an online asynchronous training module on the ability of medical students and emergency medicine (EM) residents to detect electrocardiogram (ECG) abnormalities of an acute myocardial infarction (AMI). We developed an online ECG training and testing module on AMI, with emphasis on recognizing ST elevation myocardial infarction (MI) and early activation of cardiac catheterization resources. Study participants included senior medical students and EM residents at all post-graduate levels rotating in our emergency department (ED). Participants were given a baseline set of ECGs for interpretation. This was followed by a brief interactive online training module on normal ECGs as well as abnormal ECGs representing an acute MI. Participants then underwent a post-test with a set of ECGs in which they had to interpret and decide appropriate intervention including catheterization lab activation. 148 students and 35 EM residents participated in this training in the 2012-2013 academic year. Students and EM residents showed significant improvements in recognizing ECG abnormalities after taking the asynchronous online training module. The mean score on the testing module for students improved from 5.9 (95% CI [5.7-6.1]) to 7.3 (95% CI [7.1-7.5]), with a mean difference of 1.4 (95% CI [1.12-1.68]) (p<0.0001). The mean score for residents improved significantly from 6.5 (95% CI [6.2-6.9]) to 7.8 (95% CI [7.4-8.2]) (p<0.0001). An online interactive module of training improved the ability of medical students and EM residents to correctly recognize the ECG evidence of an acute MI.

  2. Study design and rationale for biomedical shirt-based electrocardiography monitoring in relevant clinical situations: ECG-shirt study.

    Science.gov (United States)

    Balsam, Paweł; Lodziński, Piotr; Tymińska, Agata; Ozierański, Krzysztof; Januszkiewicz, Łukasz; Główczyńska, Renata; Wesołowska, Katarzyna; Peller, Michał; Pietrzak, Radosław; Książczyk, Tomasz; Borodzicz, Sonia; Kołtowski, Łukasz; Borkowski, Mariusz; Werner, Bożena; Opolski, Grzegorz; Grabowski, Marcin

    2018-01-01

    Today, the main challenge for researchers is to develop new technologies which may help to improve the diagnoses of cardiovascular disease (CVD), thereby reducing healthcare costs and improving the quality of life for patients. This study aims to show the utility of biomedical shirt-based electrocardiography (ECG) monitoring of patients with CVD in different clinical situations using the Nuubo® ECG (nECG) system. An investigator-initiated, multicenter, prospective observational study was carried out in a cardiology (adult and pediatric) and cardiac rehabilitation wards. ECG monitoring was used with the biomedical shirt in the following four independent groups of patients: 1) 30 patients after pulmonary vein isolation (PVI), 2) 30 cardiac resynchronization therapy (CRT) recipients, 3) 120 patients during cardiac rehabilitation after myocardial infarction, and 4) 40 pediatric patients with supraventricular tachycardia (SVT) before electrophysiology study. Approval for all study groups was obtained from the institutional review board. The biomedical shirt captures the electrocardiographic signal via textile electrodes integrated into a garment. The software allows the visualization and analysis of data such as ECG, heart rate, arrhythmia detecting algorithm and relative position of the body is captured by an electronic device. The major advantages of the nECG system are continuous ECG monitoring during daily activities, high quality of ECG recordings, as well as assurance of a proper adherence due to adequate comfort while wearing the shirt. There are only a few studies that have examined wearable systems, especially in pediatric populations. This study is registered in ClinicalTrials.gov: Identifier NCT03068169. (Cardiol J 2018; 25, 1: 52-59).

  3. Wavelet-Based Watermarking and Compression for ECG Signals with Verification Evaluation

    Directory of Open Access Journals (Sweden)

    Kuo-Kun Tseng

    2014-02-01

    Full Text Available In the current open society and with the growth of human rights, people are more and more concerned about the privacy of their information and other important data. This study makes use of electrocardiography (ECG data in order to protect individual information. An ECG signal can not only be used to analyze disease, but also to provide crucial biometric information for identification and authentication. In this study, we propose a new idea of integrating electrocardiogram watermarking and compression approach, which has never been researched before. ECG watermarking can ensure the confidentiality and reliability of a user’s data while reducing the amount of data. In the evaluation, we apply the embedding capacity, bit error rate (BER, signal-to-noise ratio (SNR, compression ratio (CR, and compressed-signal to noise ratio (CNR methods to assess the proposed algorithm. After comprehensive evaluation the final results show that our algorithm is robust and feasible.

  4. THE ROLE OF ECG IN LOCALIZING THE CULPRIT VESSEL OCCLUSION IN ACUTE ST SEGMENT ELEVATION MYOCARDICAL INFARCTION WITH ANGIOGRAPHIC CORRELATION

    Directory of Open Access Journals (Sweden)

    Markandeya Rao

    2015-12-01

    Full Text Available BACKGROUND & OBJECTIVES The Electrocardiogram remains a crucial tool in the identification and management of acute myocardial infarction. A detailed analysis of patterns of ST-segment elevation may influence decisions regarding the perfusion therapy. This study was undertaken to identify the culprit vessel from ECG in patients with acute ST elevation myocardial infarction and correlate with coronary angiogram. MATERIALS & METHODS This is a prospective study, conducted on 126 patients in Osmania General Hospital, Hyderabad. Patients with ST segment elevation from ECG was evaluated to identify culprit vessel and later correlated with coronary angiogram. RESULTS Amongst 126 patients in this study, 70 patients had anterior wall and 56 patients had inferior wall myocardial infarction. ST> 1mm in V4R, ST  V3/ST  LIII Lead II was the most sensitive and ratio of STV3/STLIII >1.2 was the most specific criteria. ST in inferior leads > 1mm had maximum sensitivity in localizing occlusion in proximal D1 occlusion proximal to S1 as well. Absence of ST i in inferior leads is the most sensitive criteria in occlusion distal to S1 as well as in distal D1 in AWMI. CONCLUSION The admission ECG in patients with ST elevation AMI is valuable not only for determining early reperfusion treatment, but also provides important information to guide clinical decision-making.

  5. ECG-derived Cheyne-Stokes respiration and periodic breathing in healthy and hospitalized populations.

    Science.gov (United States)

    Tinoco, Adelita; Drew, Barbara J; Hu, Xiao; Mortara, David; Cooper, Bruce A; Pelter, Michele M

    2017-11-01

    Cheyne-Stokes respiration (CSR) has been investigated primarily in outpatients with heart failure. In this study we compare CSR and periodic breathing (PB) between healthy and cardiac groups. We compared CSR and PB, measured during 24 hr of continuous 12-lead electrocardiographic (ECG) Holter recording, in a group of 90 hospitalized patients presenting to the emergency department with symptoms suggestive of acute coronary syndrome (ACS) to a group of 100 healthy ambulatory participants. We also examined CSR and PB in the 90 patients presenting with ACS symptoms, divided into a group of 39 (43%) with confirmed ACS, and 51 (57%) with a cardiac diagnosis but non-ACS. SuperECG software was used to derive respiration and then calculate CSR and PB episodes from the ECG Holter data. Regression analyses were used to analyze the data. We hypothesized SuperECG software would differentiate between the groups by detecting less CSR and PB in the healthy group than the group of patients presenting to the emergency department with ACS symptoms. Hospitalized patients with suspected ACS had 7.3 times more CSR episodes and 1.6 times more PB episodes than healthy ambulatory participants. Patients with confirmed ACS had 6.0 times more CSR episodes and 1.3 times more PB episodes than cardiac non-ACS patients. Continuous 12-lead ECG derived CSR and PB appear to differentiate between healthy participants and hospitalized patients. © 2017 Wiley Periodicals, Inc.

  6. Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

    OpenAIRE

    Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner

    2014-01-01

    Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the...

  7. Cost-effectiveness analysis of computerized ECG interpretation system in an ambulatory health care organization.

    Science.gov (United States)

    Carel, R S

    1982-04-01

    The cost-effectiveness of a computerized ECG interpretation system in an ambulatory health care organization has been evaluated in comparison with a conventional (manual) system. The automated system was shown to be more cost-effective at a minimum load of 2,500 patients/month. At larger monthly loads an even greater cost-effectiveness was found, the average cost/ECG being about $2. In the manual system the cost/unit is practically independent of patient load. This is primarily due to the fact that 87% of the cost/ECG is attributable to wages and fees of highly trained personnel. In the automated system, on the other hand, the cost/ECG is heavily dependent on examinee load. This is due to the relatively large impact of equipment depreciation on fixed (and total) cost. Utilization of a computer-assisted system leads to marked reduction in cardiologists' interpretation time, substantially shorter turnaround time (of unconfirmed reports), and potential provision of simultaneous service at several remotely located "heart stations."

  8. Noise-aware dictionary-learning-based sparse representation framework for detection and removal of single and combined noises from ECG signal.

    Science.gov (United States)

    Satija, Udit; Ramkumar, Barathram; Sabarimalai Manikandan, M

    2017-02-01

    Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal.

  9. Acute ECG changes and chest pain induced by neck motion in patients with cervical hernia--a case report.

    Science.gov (United States)

    Güler, N; Bilge, M; Eryonucu, B; Cirak, B

    2000-10-01

    We report two cases of acute cervical angina and ECG changes induced by anteflexion of the head. Cervical angina is defined as chest pain that resembles true cardiac angina but originates from cervical discopathy with nerve root compression. In these patients, Prinzmetal's angina, valvular heart disease, congenital heart disease, left ventricular aneurysm, and cardiomyopathy were excluded. After all, the patient's chest pain was reproduced by anteflexion of head, at this time, their ECGs showed nonspecific ST-T changes in the inferior and anterior leads different from the basal ECG. ECG changes returned to normal when the patient's neck moved to the neutral position. To our knowledge, these are the first cases of cervical angina associated with acute ECG changes by neck motion.

  10. What adult electrocardiogram (ECG) diagnoses and/or findings do residents in emergency medicine need to know?

    Science.gov (United States)

    Patocka, Catherine; Turner, Joel; Wiseman, Jeffrey

    2015-11-01

    There is no evidence-based description of electrocardiogram (ECG) interpretation competencies for emergency medicine (EM) trainees. The first step in defining these competencies is to develop a prioritized list of adult ECG findings relevant to EM contexts. The purpose of this study was to categorize the importance of various adult ECG diagnoses and/or findings for the EM trainee. We developed a list of potentially important adult ECG diagnoses/findings and conducted a Delphi opinion-soliciting process. Participants used a 4-point Likert scale to rate the importance of each diagnosis for EM trainees. Consensus was defined as a minimum of 75% agreement at the second round or later. In the absence of consensus, stability was defined as a shift of 20% or less after successive rounds. A purposive sampling of 22 emergency physicians participated in the Delphi process, and 16 (72%) completed the process. Of those, 15 were from 11 different EM training programs across Canada and one was an expert in EM electrocardiography. Overall, 78 diagnoses reached consensus, 42 achieved stability and one diagnosis achieved neither consensus nor stability. Out of 121 potentially important adult ECG diagnoses, 53 (44%) were considered "must know" diagnoses, 61 (50%) "should know" diagnoses, and 7 (6%) "nice to know" diagnoses. We have categorized adult ECG diagnoses within an EM training context, knowledge of which may allow clinical EM teachers to establish educational priorities. This categorization will also facilitate the development of an educational framework to establish EM trainee competency in ECG interpretation.

  11. Relationship between echocardiographic LV mass and ECG based left ventricular voltages in an adolescent population: related or random?

    Science.gov (United States)

    Czosek, Richard J; Cnota, James F; Knilans, Timothy K; Pratt, Jesse; Guerrier, Karine; Anderson, Jeffrey B

    2014-09-01

    In attempts to detect diseases that may place adolescents at risk for sudden death, some have advocated for population-based screening. Controversy exists over electrocardiography (ECG) screening due to the lack of specificity, cost, and detrimental effects of false positive or extraneous outcomes. Analyze the relationship between precordial lead voltage on ECG and left ventricle (LV) mass by echocardiogram in adolescent athletes. Retrospective cohort analysis of a prospectively obtained population of self-identified adolescent athletes during sports screening with ECG and echocardiogram. Correlation between ECG LV voltages (R wave in V6 [RV6] and S wave in lead V1 [SV1]) was compared to echocardiogram-based measurements of left ventricular mass. Potential effects on ECG voltages by body anthropometrics, including weight, body mass index (BMI), and body surface area were analyzed, and ECG voltages indexed to BMI were compared to LV mass indices to analyze for improved correlation. A total of 659 adolescents enrolled in this study (64% male). The mean age was 15.4 years (14-18). The correlations between LV mass and RV6, SV1, and RV6 + SV1 were all less than 0.20. The false positive rate for abnormal voltages was relatively high (5.5%) but improved if abnormal voltages in both RV6 and SV1 were mandated simultaneously (0%). Indexing ECG voltages to BMI significantly improved correlation to LV mass, though false positive findings were increased (12.9%). There is poor correlation between ECG precordial voltages and echocardiographic LV mass. This relationship is modified by BMI. This finding may contribute to the poor ECG screening characteristics. ©2014 Wiley Periodicals, Inc.

  12. Feasibility of Using Mobile ECG Recording Technology to Detect Atrial Fibrillation in Low-Resource Settings.

    Science.gov (United States)

    Evans, Grahame F; Shirk, Arianna; Muturi, Peter; Soliman, Elsayed Z

    2017-12-01

    Screening for atrial fibrillation (AF), a major risk factor for stroke that is on the rise in Africa, is becoming increasingly critical. This study sought to examine the feasibility of using mobile electrocardiogram (ECG) recording technology to detect AF. In this prospective observational study, we used a mobile ECG recorder to screen 50 African adults (66% women; mean age 54.3 ± 20.5 years) attending Kijabe Hospital (Kijabe, Kenya). Five hospital health providers involved in this study's data collection process also completed a self-administered survey to obtain information on their access to the Internet and mobile devices, both factors necessary to implement ECG mobile technology. Outcome measures included feasibility (completion of the study and recruitment of the patients on the planned study time frame) and the yield of the screening by the mobile ECG technology (ability to detect previously undiagnosed AF). Patients were recruited in a 2-week period as planned; only 1 of the 51 patients approached refused to participate (98% acceptance rate). All of the 50 patients who agreed to participate completed the test and produced readable ECGs (100% study completion rate). ECG tracings of 4 of the 50 patients who completed the study showed AF (8% AF yield), and none had been previously diagnosed with AF. When asked about continuous access to Internet and personal mobile devices, almost all of the health care providers surveyed answered affirmatively. Using mobile ECG technology in screening for AF in low-resource settings is feasible, and can detect a significant proportion of AF cases that will otherwise go undiagnosed. Further study is needed to examine the cost-effectiveness of this approach for detection of AF and its effect on reducing the risk of stroke in developing countries. Copyright © 2016 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.

  13. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology

    OpenAIRE

    Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M. B.

    2015-01-01

    This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has ...

  14. Study of ECG changes and its relation to mortality in cases of cerebrovascular accidents.

    Science.gov (United States)

    Purushothaman, Suja; Salmani, Deepalaxmi; Prarthana, Kaleramma Gopalakrishna; Bandelkar, Srinidhi Muddanna Gundappa; Varghese, Sarah

    2014-07-01

    Its being long recognized about the highly debilitating and destructive nature of cerebrovascular accidents (CVAs). Around the world CVAs has posed as a major factor in medical morbidity and mortality. It has thrown up challenges with regards to their medical management and also towards posttreatment rehabilitation. It is well-known that neurologic disorder contributes variously towards varied electrocardiogram (ECG) changes and stroke is no exception. To study the ECG changes and its relation to mortality in cases of CVA. A total of 100 patients with acute stroke were enrolled in the study. All the 100 patients underwent ECG recording within first 24 h of admission. The patients were divided into ischemic and hemorrhagic group depending on the nature of lesion. Out of 100 cases, 58 were ischemic and 42 were hemorrhagic. The ECG changes were noted in 78 patients. Among the ischemic group, the changes noted in the ECG were: T wave inversion (34.48%), ST segment depression (32.75%), QTc prolongation (29.31%), and presence of U waves (27.58%). In cases of hemorrhagic stroke, it was: T wave inversion (33.33%), arrhythmias (33.33%), U waves (30.95%), and ST segment depression (23.80%). Mortality was higher in patients with ST-T changes in ischemic group (66.66%) and in patients with positive U waves (60%) in hemorrhagic group. In acute stroke patients, changes in ECG were commonly seen. The changes varied from T-wave inversion to ST segment depression in ischemic stroke. In hemorrhagic stroke it consisted of T wave inversion and arrhythmias. Overall mortality was high in cases of hemorrhagic compared to ischemic group.

  15. Fetal electrocardiogram (ECG) for fetal monitoring during labour.

    Science.gov (United States)

    Neilson, James P

    2015-12-21

    Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average

  16. Automatic detection of slow-wave sleep and REM-sleep stages using polysomnographic ECG signals

    International Nuclear Information System (INIS)

    Khemiri, S.; Aloui, K.; Naceur, M. S.

    2011-01-01

    We describe in this paper a new approach of classifying the different sleep stages only by focusing on the polysomnographic ECG signals. We show the pre-processing technique of the ECG signals. At the same time the identifcation and elimination of the different types of artifacts which contain the signal and its reconstruction are shown. The automatic classification of the slow-deep sleep and the rapid eye movement sleep called in this work REM-sleep consists in extracting physiological indicators that characterize these two sleep stages through the polysomnographic ECG signal. In other words, this classification is based on the analysis of the cardiac rhythm during a night's sleep.

  17. Future cardiac events in patients with ischemic ECG changes during adenosine infusion as a myocardial stress agent and normal cardiac scan.

    Science.gov (United States)

    Amer, Hamid; Niaz, Khalid; Hatazawa, Jun; Gasmelseed, Ahmed; Samiri, Hussain Al; Al Othman, Maram; Hammad, Mai Al

    2017-11-01

    We sought to determine the prognostic importance of adenosine-induced ischemic ECG changes in patients with normal single-photon emission computed tomography myocardial perfusion images (MPI). We carried out a retrospective analysis of 765 patients undergoing adenosine MPI between January 2013 and January 2015. Patients with baseline ECG abnormalities and/or abnormal scan were excluded. Overall, 67 (8.7%) patients had ischemic ECG changes during adenosine infusion in the form of ST depression of 1 mm or more. Of these, 29 [43% (3.8% of all patients)] had normal MPI (positive ECG group). An age-matched and sex-matched group of 108 patients with normal MPI without ECG changes served as control participants (negative ECG group). During a mean follow-up duration of 33.3±6.1 months, patients in the positive ECG group did not have significantly more adverse cardiac events than those in the negative ECG group. One (0.9%) patient in the negative ECG group had a nonfatal myocardial infarction (0.7% annual event rate after a negative MPI). Also in this group, two (1.8%) patients admitted with a diagnosis of CAD where they have been ruled out by angiography. A fourth case in this, in the negative ECG group, was admitted because of heart failure that proved to be secondary to a pulmonary cause and not CAD. A case only in the positive ECG group was admitted as a CAD that was ruled out by coronary angiography. Patients with normal myocardial perfusion scintigraphy in whom ST-segment depression develops during adenosine stress test appear to have no increased risk for future cardiac events compared with similar patients without ECG evidence of ischemia.

  18. Spatiotemporal Characteristics of QRS Complexes Enable the Diagnosis of Brugada Syndrome Regardless of the Appearance of a Type 1 ECG.

    Science.gov (United States)

    Guillem, Maria S; Climent, Andreu M; Millet, José; Berne, Paola; Ramos, Rafael; Brugada, Josep; Brugada, Ramon

    2016-05-01

    The diagnosis of Brugada syndrome based on the ECG is hampered by the dynamic nature of its ECG manifestations. Brugada syndrome patients are only 25% likely to present a type 1 ECG. The objective of this study is to provide an ECG diagnostic criterion for Brugada syndrome patients that can be applied consistently even in the absence of a type 1 ECG. We recorded 67-lead body surface potential maps from 94 Brugada syndrome patients and 82 controls (including right bundle branch block patients and healthy individuals). The spatial propagation direction during the last r' wave and the slope at the end of the QRS complex were measured and compared between patients groups. Receiver-operating characteristic curves were constructed for half of the database to identify optimal cutoff values; sensitivity and specificity for these cutoff values were measured in the other half of the database. A spontaneous type 1 ECG was present in only 30% of BrS patients. An orientation in the sagittal plane ECG recordings can enable a robust identification of BrS even without the presence of a type 1 ECG. © 2016 Wiley Periodicals, Inc.

  19. Estimating actigraphy from motion artifacts in ECG and respiratory effort signals.

    Science.gov (United States)

    Fonseca, Pedro; Aarts, Ronald M; Long, Xi; Rolink, Jérôme; Leonhardt, Steffen

    2016-01-01

    Recent work in unobtrusive sleep/wake classification has shown that cardiac and respiratory features can help improve classification performance. Nevertheless, actigraphy remains the single most discriminative modality for this task. Unfortunately, it requires the use of dedicated devices in addition to the sensors used to measure electrocardiogram (ECG) or respiratory effort. This paper proposes a method to estimate actigraphy from the body movement artifacts present in the ECG and respiratory inductance plethysmography (RIP) based on the time-frequency analysis of those signals. Using a continuous wavelet transform to analyze RIP, and ECG and RIP combined, it provides a surrogate measure of actigraphy with moderate correlation (for ECG+RIP, ρ = 0.74, p  <  0.001) and agreement (mean bias ratio of 0.94 and 95% agreement ratios of 0.11 and 8.45) with reference actigraphy. More important, it can be used as a replacement of actigraphy in sleep/wake classification: after cross-validation with a data set comprising polysomnographic (PSG) recordings of 15 healthy subjects and 25 insomniacs annotated by an external sleep technician, it achieves a statistically non-inferior classification performance when used together with respiratory features (average κ of 0.64 for 15 healthy subjects, and 0.50 for a dataset with 40 healthy and insomniac subjects), and when used together with respiratory and cardiac features (average κ of 0.66 for 15 healthy subjects, and 0.56 for 40 healthy and insomniac subjects). Since this method eliminates the need for a dedicated actigraphy device, it reduces the number of sensors needed for sleep/wake classification to a single sensor when using respiratory features, and to two sensors when using respiratory and cardiac features without any loss in performance. It offers a major benefit in terms of comfort for long-term home monitoring and is immediately applicable for legacy ECG and RIP monitoring devices already used in clinical

  20. Pre-Hospital ECG E-Transmission for Patients with Suspected Myocardial Infarction in the Highlands of Scotland

    Directory of Open Access Journals (Sweden)

    Gordon F. Rushworth

    2014-02-01

    Full Text Available Patients with ST elevation myocardial infarction (STEMI require prompt treatment, best done by primary percutaneous coronary intervention (PPCI. However, for patients unable to receive PPCI, immediate pre-hospital thrombolysis (PHT is the best alternative. Evidence indicates that diagnostic and management support for staff increases the use of PHT. This study aimed to describe the patient demographics and management of patients, to determine any potential inter-area differences in referral rates to the ECG e-transmission service and to explore the views and experiences of key staff involved in ECG e-transmission within NHS Highland. Data from 2,025 patient episodes of ECG e-transmission identified a statistically significant geographical variation in ECG e-transmission and PHT delivery. Scottish Ambulance Service (SAS staff were more likely than GPs to deliver PHT overall, however, GPs were more likely to deliver in remote areas. Interviews with six Cardiac Care Unit (CCU nurses and six SAS staff highlighted their positive views of ECG e-transmission, citing perceived benefits to patients and interprofessional relationships. Poor access to network signal was noted to be a barrier to engaging in the system. This study has demonstrated that a specialist triage service based on e-transmission of ECGs in patients with suspected STEMI can be implemented in a diverse geographical setting. Work is needed to ensure equity of the service for all patients.

  1. A first approach to Arrhythmogenic Cardiomyopathy detection through ECG and Hidden Markov Models

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Serrano, S.; Sanz Sanchez, J.; Martínez Hinarejos, C.D.; Igual Muñoz, B.; Millet Roig, J.; Zorio Grima, Z.; Castells, F.

    2016-07-01

    Arrhythmogenic Cardiomyopathy (ACM) is a heritable cardiac disease causing sudden cardiac death in young people. Its clinical diagnosis includes major and minor criteria based on alterations of the electrocardiogram (ECG). The aim of this study is to evaluate Hidden Markov Models (HMM) in order to assess its possible potential of classification among subjects affected by ACM and those relatives who do not suffer the disease through 12-lead ECG recordings. Database consists of 12-lead ECG recordings from 32 patients diagnosed with ACM, and 37 relatives of those affected, but without gene mutation. Using the HTK toolkit and a hold-out strategy in order to train and evaluate a set of HMM models, we performed a grid search through the number of states and Gaussians across these HMM models. Results show that two different HMM models achieved the best balance between sensibility and specificity. The first one needed 35 states and 2 Gaussians and its performance was 0.7 and 0.8 in sensibility and specificity respectively. The second one achieved a sensibility and specificity values of 0.8 and 0.7 respectively with 50 states and 4 Gaussians. The results of this study show that HMM models can achieve an acceptable level of sensibility and specificity in the classification among ECG registers between those affected by ACM and the control group. All the above suggest that this approach could help to detect the disease in a non-invasive way, especially within the context of family screening, improving sensitivity in detection by ECG. (Author)

  2. Response of the ECG to short-term diuresis in patients with heart failure.

    Science.gov (United States)

    Madias, John E; Song, Jessica; White, C Michael; Kalus, James S; Kluger, Jeffrey

    2005-07-01

    Increase in the amplitude of electrocardiogram (ECG) QRS complexes has been observed in patients treated for heart failure (HF), but the underlying mechanism has not been delineated. Also, correlation of augmentation of the QRS potentials with loss of weight has been noted in patients recovering from anasarca of varying etiology, or after hemodialysis. We assessed the effect of diuresis-based fluid loss in patients treated for HF on the amplitude of ECG QRS complexes. This is a cohort study based on ECG and other data from a previously published investigation of patients with HF conducted at a university affiliated hospital, which used new measurements and analysis, performed by a totally blinded investigator based at another institution. Twenty-one patients (10 men) aged 70.5+/-12.7 years, 13 with ischemic, and 8 with nonischemic cardiomyopathy, were admitted to the hospital for management of exacerbated HF and were observed for 48 hours. The patients received diuresis, and had routine laboratory testing, documentation of the net fluid lost, and recording of ECGs prior to the initiation of therapy and at 24 and 48 hours. Percent change (%Delta) over the course of observation in the sums of the amplitude of QRS complexes from 12 leads (SigmaQRS12), 6-limb leads (SigmaQRS6), and leads 1+2 (SigmaQRS2) in mm of standard ECGs were correlated with net fluid loss corrected for admission weight in mL/kg. Fluid loss amounted to 3204.9+/-1399.5 mL in the course of 40+/-23 hours of diuresis. SigmaQRS12 was 160.9+/-42.3 mm before and 170.0+/-50.7 mm after diuresis (P=0. 024). Percent change in SigmaQRS12, SigmaQRS6, and SigmaQRS2 correlated well with the net fluid loss (r=-0.70, -0.82, -0.61, and P=0.002, 0.0005, 0.001) correspondingly. Changes in sums of the amplitude of QRS complexes of the standard ECG correlates well with net fluid loss in response to short-term diuresis in patients with HF. Change in the SigmaQRS12, SigmaQRS6, and SigmaQRS2 from ECGs before and after

  3. Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun; Fujioka, Chikako; Kiguchi, Masao; Kohno, Shingo [Hiroshima University Hospital, Department of Clinical Radiology, Hiroshima (Japan); Yamamoto, Hideya; Kitagawa, Toshiro [Hiroshima University, Department of Molecular and Internal Medicine, Division of Clinical Medical Science, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan); Ito, Katsuhide [Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan)

    2009-10-15

    The purpose of this study was to compare coronary 64-slice CT angiography (CTA) protocols, specifically prospective electrocardiograph (ECG)-triggered and retrospective ECG-gated CT acquisition performed using a tube voltage of 140 kV and 120 kV, regarding intracoronary stent imaging. Coronary artery stents (n=12) with artificial in-stent restenosis (50% luminal reduction, 40 HU) on a cardiac phantom were examined by CT at heart rates of 50-75 beats per minute (bpm). The subjective visibility of in-stent restenosis was evaluated with a three-point scale (1 clearly visible, 2 visible, and 3 not visible), and artificial lumen narrowing [(inner stent diameter - measured lumen diameter)/inner stent diameter], lumen attenuation increase ratio [(in-stent attenuation - coronary lumen attenuation)/coronary lumen attenuation], and signal-to-noise ratio of in-stent lumen were determined. The effective dose was estimated. The artificial lumen narrowing (mean 43%), the increase of lumen attenuation (mean 46%), and signal-to-noise ratio (mean 7.8) were not different between CT acquisitions (p=0.12-0.91). However, the visibility scores of in-stent restenosis were different (p<0.05) between ECG-gated CTA techniques: (a) 140-kV prospective (effective dose 4.6 mSv), 1.6; (b) 120-kV prospective (3.3 mSv), 1.8; (c) 140-kV retrospective (16.4-18.8 mSv), 1.9; and (d) 120-kV retrospective (11.0-13.4 mSv), 1.9. Thus, 140-kV prospective ECG-triggered CTA improves coronary in-stent restenosis visibility at a lower radiation dose compared with retrospective ECG-gated CTA. (orig.)

  4. A Modular Low-Complexity ECG Delineation Algorithm for Real-Time Embedded Systems.

    Science.gov (United States)

    Bote, Jose Manuel; Recas, Joaquin; Rincon, Francisco; Atienza, David; Hermida, Roman

    2018-03-01

    This work presents a new modular and low-complexity algorithm for the delineation of the different ECG waves (QRS, P and T peaks, onsets, and end). Involving a reduced number of operations per second and having a small memory footprint, this algorithm is intended to perform real-time delineation on resource-constrained embedded systems. The modular design allows the algorithm to automatically adjust the delineation quality in runtime to a wide range of modes and sampling rates, from a ultralow-power mode when no arrhythmia is detected, in which the ECG is sampled at low frequency, to a complete high-accuracy delineation mode, in which the ECG is sampled at high frequency and all the ECG fiducial points are detected, in the case of arrhythmia. The delineation algorithm has been adjusted using the QT database, providing very high sensitivity and positive predictivity, and validated with the MIT database. The errors in the delineation of all the fiducial points are below the tolerances given by the Common Standards for Electrocardiography Committee in the high-accuracy mode, except for the P wave onset, for which the algorithm is above the agreed tolerances by only a fraction of the sample duration. The computational load for the ultralow-power 8-MHz TI MSP430 series microcontroller ranges from 0.2% to 8.5% according to the mode used.

  5. Antimyotonic therapy with tocainide under ECG control in the myotonic dystrophy of Curschmann-Steinert.

    Science.gov (United States)

    Mielke, U; Haass, A; Sen, S; Schmidt, W

    1985-01-01

    Ten patients suffering from advanced myotonic dystrophy with severe myotonic symptoms were treated with 800-1200 mg/day of the anti-arrhythmic drug tocainide (Xylotocan). All patients reported a marked subjective improvement of myotonia, which was confirmed by objective tests. Except for a slight QT-prolongation in one patient, the ECG was not significantly altered by the treatment. Twenty-four-hour ECG after treatment disclosed that pre-existing ventricular arrhythmia disappeared in three cases. The occurrence of complex ventricular arrhythmia in two patients under treatment was not necessarily due to specific effects of the drug but might be explained by the high spontaneous variability of rhythm disorders. In these patients suffering from myotonic dystrophy with typical cardiomyopathy no deleterious effects of the drug were observed, especially no cardiac arrhythmias which would have necessitated interruption of treatment. Therefore, the authors recommend symptomatic therapy with tocainide for myotonia and paramyotonia congenita, as well as in myotonic dystrophy patients suffering from marked myotonic stiffness. ECG and 24-h ECG should be carefully recorded as necessary in any treatment with anti-arrhythmic drugs.

  6. Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis.

    Science.gov (United States)

    Lee, W K; Yoon, H; Park, K S

    2016-07-01

    Since heart rate variability (HRV) analysis is widely used to evaluate the physiological status of the human body, devices specifically designed for such applications are needed. To this end, we developed a smart electrocardiography (ECG) patch. The smart patch measures ECG using three electrodes integrated into the patch, filters the measured signals to minimize noise, performs analog-to-digital conversion, and detects R-peaks. The measured raw ECG data and the interval between the detected R-peaks can be recorded to enable long-term HRV analysis. Experiments were performed to evaluate the performance of the built-in R-wave detection, robustness of the device under motion, and applicability to the evaluation of mental stress. The R-peak detection results obtained with the device exhibited a sensitivity of 99.29%, a positive predictive value of 100.00%, and an error of 0.71%. The device also exhibited less motional noise than conventional ECG recording, being stable up to a walking speed of 5 km/h. When applied to mental stress analysis, the device evaluated the variation in HRV parameters in the same way as a normal ECG, with very little difference. This device can help users better understand their state of health and provide physicians with more reliable data for objective diagnosis.

  7. NInFEA: an embedded framework for the real-time evaluation of fetal ECG extraction algorithms.

    Science.gov (United States)

    Pani, Danilo; Barabino, Gianluca; Raffo, Luigi

    2013-02-01

    Fetal electrocardiogram (ECG) extraction from non-invasive biopotential recordings is a long-standing research topic. Despite the significant number of algorithms presented in the scientific literature, it is difficult to find information about embedded hardware implementations able to provide real-time support for the required features, bridging the gap between theory and practice. This article presents the NInFEA (non-invasive fetal ECG analysis) tool, an embedded hardware/software framework based on the hybrid dual-core OMAP-L137 low-power processor for the real-time evaluation of fetal ECG extraction algorithms. The hybrid platform, including a digital signal processor (DSP) and a general-purpose processor (GPP), allows achieving the best performance compared with single-core architectures. The GPP provides a portable graphical user interface, whereas the DSP is extensively used for advanced signal processing tasks. As a case study, three state-of-the-art fetal ECG extraction algorithms have been ported onto NInFEA, along with some support routines needed to provide the additional information required by the clinicians and supported by the user interface. NInFEA can be regarded both as a reference design for similar applications and as a common embedded low-power testbed for real-time fetal ECG extraction algorithms.

  8. Effect of Cardiac Phases and Conductivity Inhomogeneities of the Thorax Models on ECG Lead Selection and Reconstruction

    National Research Council Canada - National Science Library

    Takano, Noriyuki

    2001-01-01

    ECG lead selection and reconstruction were investigated in the present study using ECG source-to-measurement transfer matrices computed in inhomogeneous and homogeneous conductor thorax-heart models...

  9. Comparison between retrospective gating and ECG triggering in magnetic resonance velocity mapping

    DEFF Research Database (Denmark)

    Søndergaard, L; Ståhlberg, F; Thomsen, C

    1993-01-01

    ECG-triggered cinematographic studies of the cardiovascular system are hampered by several technical restrictions such as the inability to image end-diastole, ghosting, varying signal intensity, and phase contributions from eddy currents. Retrospective gating may solve these problems, but involves...... of flow pulses. However, by reducing the time window retrospectively gated flow measurements were in good agreement with those that are ECG triggered. When fulfilling the demand of a narrow time window for interpolation, retrospective gating offers several advantages in MR velocity mapping....

  10. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study.

    Science.gov (United States)

    Rossetti, Francesca; Pittiruti, Mauro; Lamperti, Massimo; Graziano, Ugo; Celentano, Davide; Capozzoli, Giuseppe

    2015-01-01

    The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.

  11. A ECG Signal Gathering and Displaying System Based on AVR

    Science.gov (United States)

    Ning, Li; Ruilan, Zhang; Jian, Liu; Xiaochen, Wang; Shuying, Chen; Zhuolin, Lang

    2017-12-01

    This article introduces a kind of system which is based on the AVR to acquire the data of ECG. Such system using the A/D function of ATmega8 chip and the lattice graph LCD to design ECG heart acquisition satisfies the demands above. This design gives a composition of hardware and programming of software about the system in detail which has mainly realized the real-time gathering, the amplifier, the filter, the A/D transformation and the LCD display. Since the AVR includes A/D transformation function and support embedded C language programming, it reduces the peripheral circuit, further more it also decreases the time to design and debug this system.

  12. Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology.

    Science.gov (United States)

    Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M B

    2015-01-01

    This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet.

  13. Multiple ECG Fiducial Points-Based Random Binary Sequence Generation for Securing Wireless Body Area Networks.

    Science.gov (United States)

    Zheng, Guanglou; Fang, Gengfa; Shankaran, Rajan; Orgun, Mehmet A; Zhou, Jie; Qiao, Li; Saleem, Kashif

    2017-05-01

    Generating random binary sequences (BSes) is a fundamental requirement in cryptography. A BS is a sequence of N bits, and each bit has a value of 0 or 1. For securing sensors within wireless body area networks (WBANs), electrocardiogram (ECG)-based BS generation methods have been widely investigated in which interpulse intervals (IPIs) from each heartbeat cycle are processed to produce BSes. Using these IPI-based methods to generate a 128-bit BS in real time normally takes around half a minute. In order to improve the time efficiency of such methods, this paper presents an ECG multiple fiducial-points based binary sequence generation (MFBSG) algorithm. The technique of discrete wavelet transforms is employed to detect arrival time of these fiducial points, such as P, Q, R, S, and T peaks. Time intervals between them, including RR, RQ, RS, RP, and RT intervals, are then calculated based on this arrival time, and are used as ECG features to generate random BSes with low latency. According to our analysis on real ECG data, these ECG feature values exhibit the property of randomness and, thus, can be utilized to generate random BSes. Compared with the schemes that solely rely on IPIs to generate BSes, this MFBSG algorithm uses five feature values from one heart beat cycle, and can be up to five times faster than the solely IPI-based methods. So, it achieves a design goal of low latency. According to our analysis, the complexity of the algorithm is comparable to that of fast Fourier transforms. These randomly generated ECG BSes can be used as security keys for encryption or authentication in a WBAN system.

  14. An optimized compression algorithm for real-time ECG data transmission in wireless network of medical information systems.

    Science.gov (United States)

    Cho, Gyoun-Yon; Lee, Seo-Joon; Lee, Tae-Ro

    2015-01-01

    Recent medical information systems are striving towards real-time monitoring models to care patients anytime and anywhere through ECG signals. However, there are several limitations such as data distortion and limited bandwidth in wireless communications. In order to overcome such limitations, this research focuses on compression. Few researches have been made to develop a specialized compression algorithm for ECG data transmission in real-time monitoring wireless network. Not only that, recent researches' algorithm is not appropriate for ECG signals. Therefore this paper presents a more developed algorithm EDLZW for efficient ECG data transmission. Results actually showed that the EDLZW compression ratio was 8.66, which was a performance that was 4 times better than any other recent compression method widely used today.

  15. Clinical usefullness of ECG-triggered single photon emission comuter tomography of blood-pool

    International Nuclear Information System (INIS)

    Eilles, Chr.; Boerner, W.; Strauss, P.; Gerhards, W.; Reiners, Ch.

    1982-01-01

    ECT allows direct measurement of the volume of an organ and imaging without disturbing background-superposition. This makes ECT to an useful instrument for ECG-gated blood-pool imaging. Acquisition is made after the injection of 25 mCi Tc-99m HSA with a rotating Anger-Camera-System. ECG-gated imaging is done for each projection; herewith 50-70 cycles per projection are added according to the phase of the heart-cycle. Transversal-Sections of the heart are reconstructed with filtered-back-projection. For each slice a representative cycle, consisting of 10-16 frames, is computed. As shown by our group before a good quality of the reconstructed images can be obtained. Comparison is made with the results of the ECG-gated blood-pool-ECT, the results of the conventional blood-pool-studies and with the results of Laevo-Cardiography. (Author)

  16. Continuous control systems for non-contact ECG

    Science.gov (United States)

    Kodkin, Vladimir L.; Yakovleva, Galina V.; Smirnov, Alexey S.

    2017-03-01

    South Ural State University is still conducting the research work dedicated to innovations in biomedicine. Development of system for continuous control and diagnosis of the functional state in large groups of people is based on studies of non-contact ECG recording reported by the authors at the SPIE conference in 2016. The next stage of studies has been performed this year.

  17. ECG-gated myocardial imaging with 201Tl

    International Nuclear Information System (INIS)

    Baehre, M.

    1980-01-01

    ECG-gated myocardial scintigraphy by means of 201 TI was performed in 11 patients. Good scintigrams could be gained by using long imaging times, but there was no additional information when compared with static images. Disadvantages were long imaging time, higher technical expenditure, and the smaller number of projections. Furthermore, there is no possibility of performing myocardial imaging under stress. (orig.) [de

  18. Electrocardiogram Pattern Recognition and Analysis Based on Artificial Neural Networks and Support Vector Machines: A Review

    Directory of Open Access Journals (Sweden)

    Mario Sansone

    2013-01-01

    Full Text Available Computer systems for Electrocardiogram (ECG analysis support the clinician in tedious tasks (e.g., Holter ECG monitored in Intensive Care Units or in prompt detection of dangerous events (e.g., ventricular fibrillation. Together with clinical applications (arrhythmia detection and heart rate variability analysis, ECG is currently being investigated in biometrics (human identification, an emerging area receiving increasing attention. Methodologies for clinical applications can have both differences and similarities with respect to biometrics. This paper reviews methods of ECG processing from a pattern recognition perspective. In particular, we focus on features commonly used for heartbeat classification. Considering the vast literature in the field and the limited space of this review, we dedicated a detailed discussion only to a few classifiers (Artificial Neural Networks and Support Vector Machines because of their popularity; however, other techniques such as Hidden Markov Models and Kalman Filtering will be also mentioned.

  19. Prevalence and prognostic significance of ECG abnormalities in HIV-infected patients: results from the Strategies for Management of Antiretroviral Therapy study

    DEFF Research Database (Denmark)

    Soliman, Elsayed Z; Prineas, Ronald J; Roediger, Mollie P

    2011-01-01

    BACKGROUND: It remains debated whether to include resting electrocardiogram (ECG) in the routine care of human immunodeficiency virus (HIV)-infected patients. METHODS: This analysis included 4518 HIV-infected patients (28% women and 29% blacks) from the Strategies for Management of Antiretroviral...... Therapy study, a clinical trial aimed to compare 2 HIV treatment strategies. ECG abnormalities were classified using the Minnesota Code. Cox proportional hazards analysis was used to examine the association between baseline ECG abnormalities and incident cardiovascular disease (CVD). RESULTS: More than...... half of the participants (n = 2325, or 51.5%) had either minor or major ECG abnormalities. Minor ECG abnormalities (48.6%) were more common than major ECG abnormalities (7.7%). During a median follow-up of 28.7 months, 155 participants (3.4%) developed incident CVD. After adjusting for the study...

  20. Automated detection of heart ailments from 12-lead ECG using complex wavelet sub-band bi-spectrum features.

    Science.gov (United States)

    Tripathy, Rajesh Kumar; Dandapat, Samarendra

    2017-04-01

    The complex wavelet sub-band bi-spectrum (CWSB) features are proposed for detection and classification of myocardial infarction (MI), heart muscle disease (HMD) and bundle branch block (BBB) from 12-lead ECG. The dual tree CW transform of 12-lead ECG produces CW coefficients at different sub-bands. The higher-order CW analysis is used for evaluation of CWSB. The mean of the absolute value of CWSB, and the number of negative phase angle and the number of positive phase angle features from the phase of CWSB of 12-lead ECG are evaluated. Extreme learning machine and support vector machine (SVM) classifiers are used to evaluate the performance of CWSB features. Experimental results show that the proposed CWSB features of 12-lead ECG and the SVM classifier are successful for classification of various heart pathologies. The individual accuracy values for MI, HMD and BBB classes are obtained as 98.37, 97.39 and 96.40%, respectively, using SVM classifier and radial basis function kernel function. A comparison has also been made with existing 12-lead ECG-based cardiac disease detection techniques.

  1. Classification of Multichannel ECG Signals Using a Cross-Distance Analysis

    National Research Council Canada - National Science Library

    Shahram, Morteza

    2001-01-01

    This paper presents a multi-stage algorithm for multi-channel ECG beat classification into normal and abnormal categories using a sequential beat clustering and a cross- distance analysis algorithm...

  2. ECG-ViEW II, a freely accessible electrocardiogram database

    Science.gov (United States)

    Park, Man Young; Lee, Sukhoon; Jeon, Min Seok; Yoon, Dukyong; Park, Rae Woong

    2017-01-01

    The Electrocardiogram Vigilance with Electronic data Warehouse II (ECG-ViEW II) is a large, single-center database comprising numeric parameter data of the surface electrocardiograms of all patients who underwent testing from 1 June 1994 to 31 July 2013. The electrocardiographic data include the test date, clinical department, RR interval, PR interval, QRS duration, QT interval, QTc interval, P axis, QRS axis, and T axis. These data are connected with patient age, sex, ethnicity, comorbidities, age-adjusted Charlson comorbidity index, prescribed drugs, and electrolyte levels. This longitudinal observational database contains 979,273 electrocardiograms from 461,178 patients over a 19-year study period. This database can provide an opportunity to study electrocardiographic changes caused by medications, disease, or other demographic variables. ECG-ViEW II is freely available at http://www.ecgview.org. PMID:28437484

  3. Ventricular short-axis measurements in patients with pulmonary embolism: Effect of ECG-gating on variability, accuracy, and risk prediction

    International Nuclear Information System (INIS)

    Scheffel, Hans; Stolzmann, Paul; Leschka, Sebastian; Desbiolles, Lotus; Seifert, Burkhardt; Marincek, Borut; Alkadhi, Hatem

    2012-01-01

    Objective: To assess prospectively the intra- and interobserver variability, accuracy, and prognostic value of right and left ventricular short-axis diameter (RVd and LVd) measurements for risk stratification in patients with pulmonary embolism (PE) using ECG-gated compared to non-gated CT. Materials and methods: Sixty consecutive patients (33 women; mean age 58.7 ± 10.3 years) with suspicion of PE underwent both non-gated and ECG-gated chest CT. RVd and LVd on four-chamber views and intra- and interobserver agreements were calculated for both protocols. RVd/LVd ratios were calculated and were related to 30-days adverse clinical events using receiver operating characteristics with area-under-the-curve (AUC) analyses. Results: Both inter- and intraobserver variability showed narrower limits of agreement for all measurements with ECG-gated as compared to non-gated CT. Diameter measurements were significantly lower using non-ECG-gated CT as compared to ECG-gated CT for RVd and LVd (both p < .05). The AUC for the RVd/LVd ratio from ECG-gated CT was significantly larger than that from non-gated CT (0.956, 95% CI: 0.768–0.999 versus 0.675, 95% CI: 0.439–0.860; p = .048). Conclusion: RVd and LVd measurements from ECG-gated chest CT show less intra- and interobserver variability and more accurately reflect ventricular function. In our patient cohort ECG-gated chest CT allows better prediction of short-term outcome of patients with acute PE that needs to be validated in a larger outcome study

  4. Surface ECG and Fluoroscopy are Not Predictive of Right Ventricular Septal Lead Position Compared to Cardiac CT.

    Science.gov (United States)

    Rowe, Matthew K; Moore, Peter; Pratap, Jit; Coucher, John; Gould, Paul A; Kaye, Gerald C

    2017-05-01

    Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG. Eighteen patients with permanent RV leads were prospectively enrolled. Leads were placed in the RV septum (RVS) in 10 and the RV apex (RVA) in eight using fluoroscopy with anteroposterior and left anterior oblique 30° views. All patients underwent MDCT imaging and paced ECG analysis. ECG criteria were: QRS duration; QRS axis; positive or negative net QRS amplitude in leads I, aVL, V1, and V6; presence of notching in the inferior leads; and transition point in precordial leads at or after V4. Of the 10 leads implanted in the RVS, computed tomography (CT) imaging revealed seven to be at the anterior RV wall, two at the anteroseptal junction, and one in the true septum. For the eight RVA leads, four were anterior, two septal, and two anteroseptal. All leads implanted in the RVS met at least one ECG criteria (median 3, range 1-6). However, no criteria were specific for septal position as judged by MDCT. Mean QRS duration was 160 ± 24 ms in the RVS group compared with 168 ± 14 ms for RVA pacing (P = 0.38). We conclude that the surface ECG is not sufficiently accurate to determine RV septal lead tip position compared to cardiac CT. © 2017 Wiley Periodicals, Inc.

  5. Are 12-lead ECG findings associated with the risk of cardiovascular events after ischemic stroke in young adults?

    Science.gov (United States)

    Pirinen, Jani; Putaala, Jukka; Aarnio, Karoliina; Aro, Aapo L; Sinisalo, Juha; Kaste, Markku; Haapaniemi, Elena; Tatlisumak, Turgut; Lehto, Mika

    2016-11-01

    Ischemic stroke (IS) in a young patient is a disaster and recurrent cardiovascular events could add further impairment. Identifying patients with high risk of such events is therefore important. The prognostic relevance of ECG for this population is unknown. A total of 690 IS patients aged 15-49 years were included. A 12-lead ECG was obtained 1-14 d after the onset of stroke. We adjusted for demographic factors, comorbidities, and stroke characteristics, Cox regression models were used to identify independent ECG parameters associated with long-term risks of (1) any cardiovascular event, (2) cardiac events, and (3) recurrent stroke. Median follow-up time was 8.8 years. About 26.4% of patients experienced a cardiovascular event, 14.5% had cardiac events, and 14.6% recurrent strokes. ECG parameters associated with recurrent cardiovascular events were bundle branch blocks, P-terminal force, left ventricular hypertrophy, and a broader QRS complex. Furthermore, more leftward P-wave axis, prolonged QTc, and P-wave duration >120 ms were associated with increased risks of cardiac events. No ECG parameters were independently associated with recurrent stroke. A 12-lead ECG can be used for risk prediction of cardiovascular events but not for recurrent stroke in young IS patients. KEY MESSAGES ECG is an easy, inexpensive, and useful tool for identifying young ischemic stroke patients with a high risk for recurrent cardiovascular events and it has a statistically significant association with these events even after adjusting for confounding factors. Bundle branch blocks, P-terminal force, broader QRS complex, LVH according to Cornell voltage duration criteria, more leftward P-wave axis, prolonged QTc, and P-wave duration >120 ms are predictors for future cardiovascular or cardiac events in these patients. No ECG parameters were independently associated with recurrent stroke.

  6. Prospective versus retrospective ECG-gated multislice CT coronary angiography: A systematic review of radiation dose and diagnostic accuracy

    International Nuclear Information System (INIS)

    Sun Zhonghua; Ng, Kwan-Hoong

    2012-01-01

    Purpose: To perform a systematic review of the radiation dose and diagnostic accuracy of prospective versus retrospective ECG-gated multislice CT coronary angiography. Materials and methods: A search of Pubmed/Medline and Sciencedirect databases for English literature was performed to identify studies comparing prospective and retrospective ECG-gated multislice CT angiography in the diagnosis of coronary artery disease. Effective dose, dose length product, image quality and diagnostic value were compared between two groups of studies. Results: 22 studies were included for analysis. The mean effective dose of prospective ECG-gated scans was 4.5 mSv (95% CI: 3.6, 5.3 mSv), which is significantly lower than that of retrospective scans, which is 13.8 mSv (95% CI: 11.5, 16.0 mSv) (p < 0.001). The mean dose length product was 225 mGy cm (95% CI: 188, 262 mGy cm) and 822 mGy cm (95% CI: 630, 1013 mGy cm) for the prospective and retrospective ECG-gated scans, respectively, indicating a statistically significant difference between these two protocols (p < 0.0001). The mean sensitivity and specificity of multislice CT angiography in the diagnosis of coronary artery disease was 97.7% (95% CI: 93.7%, 100%) and 92.1% (95% CI: 87.2%, 97%) for prospective ECG-gated scans; 95.2% (95% CI: 91%, 99.5%) and 94.4% (95% CI: 88.5%, 100%) for retrospective ECG-gated scans, respectively, with no significant difference for sensitivity but significant difference for specificity (p = 0.047). Conclusion: Multislice CT coronary angiography with prospective ECG-gating leads to a significant reduction of radiation dose when compared to that of retrospective ECG-gating, while offering comparable image quality and diagnostic value.

  7. Prehospital ECG transmission: comparison of advanced mobile phone and facsimile devices in an urban Emergency Medical Service System.

    Science.gov (United States)

    Väisänen, Olli; Mäkijärvi, Markku; Silfvast, Tom

    2003-05-01

    To compare the speed and reliability of electrocardiogram (ECG) transmissions from the prehospital setting to a conventional table facsimile device and to an advanced mobile phone in a Helicopter Emergency Medical Service System (HEMS). Eighteen authentic ECGs stored in the memory module of a monitor defibrillator were used. The ECGs were (1) sent directly from the monitor defibrillator to a table fax and an advanced mobile phone at the HEMS base; (2) printed out and sent from a mobile fax connected to an ordinary mobile phone to the table fax and the advanced mobile phone at the HEMS base; (3) printed out and sent from an ordinary table fax as well as from a table fax connected to a satellite phone system to the receiving devices at the HEMS base. When the ECGs were sent from the table fax via satellite, the transmission times were longer to the advanced mobile phone than to the table fax at the HEMS base (1 min 54 s+/-0 min 21 s vs. 1 min 37 s+/-0 min 20 s, (mean+/-SD), (Ptransmission from the other fax devices, there were no differences in transmission times between the two receiving devices. The fastest way to transmit ECGs to the advanced mobile phone was to send it from conventional table fax (1 min 22 s+/-0 min 18 s) and the longest transmission times were with mobile fax connected to mobile phone (5 min 23 s+/-3 min 5 s). In all ECGs transmitted except one the cardiac rhythm and ST-changes could be recognised. An advanced mobile phone is as fast and reliable as a conventional table fax in receiving ECGs. A mobile phone with advanced features is a practical tool for HEMS physicians who need to evaluate ECGs in the prehospital setting.

  8. ECG denoising and fiducial point extraction using an extended Kalman filtering framework with linear and nonlinear phase observations.

    Science.gov (United States)

    Akhbari, Mahsa; Shamsollahi, Mohammad B; Jutten, Christian; Armoundas, Antonis A; Sayadi, Omid

    2016-02-01

    In this paper we propose an efficient method for denoising and extracting fiducial point (FP) of ECG signals. The method is based on a nonlinear dynamic model which uses Gaussian functions to model ECG waveforms. For estimating the model parameters, we use an extended Kalman filter (EKF). In this framework called EKF25, all the parameters of Gaussian functions as well as the ECG waveforms (P-wave, QRS complex and T-wave) in the ECG dynamical model, are considered as state variables. In this paper, the dynamic time warping method is used to estimate the nonlinear ECG phase observation. We compare this new approach with linear phase observation models. Using linear and nonlinear EKF25 for ECG denoising and nonlinear EKF25 for fiducial point extraction and ECG interval analysis are the main contributions of this paper. Performance comparison with other EKF-based techniques shows that the proposed method results in higher output SNR with an average SNR improvement of 12 dB for an input SNR of -8 dB. To evaluate the FP extraction performance, we compare the proposed method with a method based on partially collapsed Gibbs sampler and an established EKF-based method. The mean absolute error and the root mean square error of all FPs, across all databases are 14 ms and 22 ms, respectively, for our proposed method, with an advantage when using a nonlinear phase observation. These errors are significantly smaller than errors obtained with other methods. For ECG interval analysis, with an absolute mean error and a root mean square error of about 22 ms and 29 ms, the proposed method achieves better accuracy and smaller variability with respect to other methods.

  9. EP-based wavelet coefficient quantization for linear distortion ECG data compression.

    Science.gov (United States)

    Hung, King-Chu; Wu, Tsung-Ching; Lee, Hsieh-Wei; Liu, Tung-Kuan

    2014-07-01

    Reconstruction quality maintenance is of the essence for ECG data compression due to the desire for diagnosis use. Quantization schemes with non-linear distortion characteristics usually result in time-consuming quality control that blocks real-time application. In this paper, a new wavelet coefficient quantization scheme based on an evolution program (EP) is proposed for wavelet-based ECG data compression. The EP search can create a stationary relationship among the quantization scales of multi-resolution levels. The stationary property implies that multi-level quantization scales can be controlled with a single variable. This hypothesis can lead to a simple design of linear distortion control with 3-D curve fitting technology. In addition, a competitive strategy is applied for alleviating data dependency effect. By using the ECG signals saved in MIT and PTB databases, many experiments were undertaken for the evaluation of compression performance, quality control efficiency, data dependency influence. The experimental results show that the new EP-based quantization scheme can obtain high compression performance and keep linear distortion behavior efficiency. This characteristic guarantees fast quality control even for the prediction model mismatching practical distortion curve. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. FPGA-based electrocardiography (ECG signal analysis system using least-square linear phase finite impulse response (FIR filter

    Directory of Open Access Journals (Sweden)

    Mohamed G. Egila

    2016-12-01

    Full Text Available This paper presents a proposed design for analyzing electrocardiography (ECG signals. This methodology employs highpass least-square linear phase Finite Impulse Response (FIR filtering technique to filter out the baseline wander noise embedded in the input ECG signal to the system. Discrete Wavelet Transform (DWT was utilized as a feature extraction methodology to extract the reduced feature set from the input ECG signal. The design uses back propagation neural network classifier to classify the input ECG signal. The system is implemented on Xilinx 3AN-XC3S700AN Field Programming Gate Array (FPGA board. A system simulation has been done. The design is compared with some other designs achieving total accuracy of 97.8%, and achieving reduction in utilizing resources on FPGA implementation.

  11. Adaptive Fourier decomposition based R-peak detection for noisy ECG Signals.

    Science.gov (United States)

    Ze Wang; Chi Man Wong; Feng Wan

    2017-07-01

    An adaptive Fourier decomposition (AFD) based R-peak detection method is proposed for noisy ECG signals. Although lots of QRS detection methods have been proposed in literature, most detection methods require high signal quality. The proposed method extracts the R waves from the energy domain using the AFD and determines the R-peak locations based on the key decomposition parameters, achieving the denoising and the R-peak detection at the same time. Validated by clinical ECG signals in the MIT-BIH Arrhythmia Database, the proposed method shows better performance than the Pan-Tompkin (PT) algorithm in both situations of a native PT and the PT with a denoising process.

  12. Data on association between QRS duration on prehospital ECG and mortality in patients with confirmed STEMI

    DEFF Research Database (Denmark)

    Hansen, Rikke; Frydland, Martin; Møller-Helgestad, Ole Kristian

    2017-01-01

    Data presented in this article relates to the research article entitled “Association between QRS duration on prehospital ECG and mortality in patients with suspected STEMI” (Hansen et al., in press) [1]. Data on the prognostic effect of automatically recoded QRS duration on prehospital ECG...

  13. Comparative study of T-amplitude features for fitness monitoring using the ePatch® ECG recorder

    DEFF Research Database (Denmark)

    Thorpe, Julia Rosemary; Saida, Trine; Mehlsen, Jesper

    2014-01-01

    This study investigates ECG features, focusing on T-wave amplitude, from a wearable ECG device as a potential method for fitness monitoring in exercise rehabilitation. An automatic T-peak detection algorithm is presented that uses local baseline detection to overcome baseline drift without the need...

  14. High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

    Science.gov (United States)

    Zupet, Petra; Finderle, Zarko; Schlegel, Todd T.; Princi, Tanja; Starc, Vito

    2010-01-01

    High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function

  15. New system for digital to analog transformation and reconstruction of 12-lead ECGs.

    Science.gov (United States)

    Kothadia, Roshni; Kulecz, Walter B; Kofman, Igor S; Black, Adam J; Grier, James W; Schlegel, Todd T

    2013-01-01

    We describe initial validation of a new system for digital to analog conversion (DAC) and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer's 12-lead ECG hardware/software into that of any other. To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long) in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data. The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer's analog to digital converter (ADC) as the original digitization, and 28.4 µV per channel when it involved a different manufacturer's ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout. Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud-based servers.

  16. New system for digital to analog transformation and reconstruction of 12-lead ECGs.

    Directory of Open Access Journals (Sweden)

    Roshni Kothadia

    Full Text Available INTRODUCTION: We describe initial validation of a new system for digital to analog conversion (DAC and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer's 12-lead ECG hardware/software into that of any other. MATERIALS AND METHODS: To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data. RESULTS: The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer's analog to digital converter (ADC as the original digitization, and 28.4 µV per channel when it involved a different manufacturer's ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout. CONCLUSION: Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud

  17. The evolution of ambulatory ECG monitoring.

    Science.gov (United States)

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health. © 2013.

  18. Conventional QT Variability Measurement vs. Template Matching Techniques: Comparison of Performance Using Simulated and Real ECG

    Science.gov (United States)

    Baumert, Mathias; Starc, Vito; Porta, Alberto

    2012-01-01

    Increased beat-to-beat variability in the QT interval (QTV) of ECG has been associated with increased risk for sudden cardiac death, but its measurement is technically challenging and currently not standardized. The aim of this study was to investigate the performance of commonly used beat-to-beat QT interval measurement algorithms. Three different methods (conventional, template stretching and template time shifting) were subjected to simulated data featuring typical ECG recording issues (broadband noise, baseline wander, amplitude modulation) and real short-term ECG of patients before and after infusion of sotalol, a QT interval prolonging drug. Among the three algorithms, the conventional algorithm was most susceptible to noise whereas the template time shifting algorithm showed superior overall performance on simulated and real ECG. None of the algorithms was able to detect increased beat-to-beat QT interval variability after sotalol infusion despite marked prolongation of the average QT interval. The QTV estimates of all three algorithms were inversely correlated with the amplitude of the T wave. In conclusion, template matching algorithms, in particular the time shifting algorithm, are recommended for beat-to-beat variability measurement of QT interval in body surface ECG. Recording noise, T wave amplitude and the beat-rejection strategy are important factors of QTV measurement and require further investigation. PMID:22860030

  19. Conventional QT variability measurement vs. template matching techniques: comparison of performance using simulated and real ECG.

    Directory of Open Access Journals (Sweden)

    Mathias Baumert

    Full Text Available Increased beat-to-beat variability in the QT interval (QTV of ECG has been associated with increased risk for sudden cardiac death, but its measurement is technically challenging and currently not standardized. The aim of this study was to investigate the performance of commonly used beat-to-beat QT interval measurement algorithms. Three different methods (conventional, template stretching and template time shifting were subjected to simulated data featuring typical ECG recording issues (broadband noise, baseline wander, amplitude modulation and real short-term ECG of patients before and after infusion of sotalol, a QT interval prolonging drug. Among the three algorithms, the conventional algorithm was most susceptible to noise whereas the template time shifting algorithm showed superior overall performance on simulated and real ECG. None of the algorithms was able to detect increased beat-to-beat QT interval variability after sotalol infusion despite marked prolongation of the average QT interval. The QTV estimates of all three algorithms were inversely correlated with the amplitude of the T wave. In conclusion, template matching algorithms, in particular the time shifting algorithm, are recommended for beat-to-beat variability measurement of QT interval in body surface ECG. Recording noise, T wave amplitude and the beat-rejection strategy are important factors of QTV measurement and require further investigation.

  20. Association between QRS duration on prehospital ECG and mortality in patients with suspected STEMI

    DEFF Research Database (Denmark)

    Hansen, Rikke; Frydland, Martin; Møller-Helgestad, Ole Kristian

    2017-01-01

    BACKGROUND: QRS duration has previously shown association with mortality in patients with acute myocardial infarction treated with thrombolytics, less is known in patients with suspected ST segment elevation myocardial infarction (STEMI) when assessing QRS duration on prehospital ECG. Thus......, the objective was to investigate the prognostic effect of QRS duration on prehospital ECG and presence of classic left and right bundle branch block (LBBB/RBBB) for all-cause mortality in patients with suspected STEMI. METHOD: In total 2105 consecutive patients (mean age 64±13years, 72% men) with suspected...... STEMI were prospectively included. QRS duration was registered from automated QRS measurement on prehospital ECG and patients were divided according to quartiles of QRS duration (111ms). Primary endpoint was all-cause 30-day mortality. Predictors of all-cause mortality were...

  1. T wave abnormalities, high body mass index, current smoking and high lipoprotein (a levels predict the development of major abnormal Q/QS patterns 20 years later. A population-based study

    Directory of Open Access Journals (Sweden)

    Sundstrom Johan

    2006-03-01

    Full Text Available Abstract Background Most studies on risk factors for development of coronary heart disease (CHD have been based on the clinical outcome of CHD. Our aim was to identify factors that could predict the development of ECG markers of CHD, such as abnormal Q/QS patterns, ST segment depression and T wave abnormalities, in 70-year-old men, irrespective of clinical outcome. Methods Predictors for development of different ECG abnormalities were identified in a population-based study using stepwise logistic regression. Anthropometrical and metabolic factors, ECG abnormalities and vital signs from a health survey of men at age 50 were related to ECG abnormalities identified in the same cohort 20 years later. Results At the age of 70, 9% had developed a major abnormal Q/QS pattern, but 63% of these subjects had not been previously hospitalized due to MI, while 57% with symptomatic MI between age 50 and 70 had no major Q/QS pattern at age 70. T wave abnormalities (Odds ratio 3.11, 95% CI 1.18–8.17, high lipoprotein (a levels, high body mass index (BMI and smoking were identified as significant independent predictors for the development of abnormal major Q/QS patterns. T wave abnormalities and high fasting glucose levels were significant independent predictors for the development of ST segment depression without abnormal Q/QS pattern. Conclusion T wave abnormalities on resting ECG should be given special attention and correlated with clinical information. Risk factors for major Q/QS patterns need not be the same as traditional risk factors for clinically recognized CHD. High lipoprotein (a levels may be a stronger risk factor for silent myocardial infarction (MI compared to clinically recognized MI.

  2. Reliability of Left Ventricular Hypertrophy by ECG Criteria in Children with Syncope: Do the Criteria Need to be Revised?

    Science.gov (United States)

    Banerjee, Maalika M; Ramesh Iyer, V; Nandi, Deipanjan; Vetter, Victoria L; Banerjee, Anirban

    2016-04-01

    In the outpatient setting, children who present with syncope routinely undergo electrocardiograms (ECG). Because of concerns for hypertrophic cardiomyopathy, children with syncope meeting ECG criteria for left ventricular hypertrophy (LVH) will frequently undergo an echocardiogram. Our objectives were to determine whether Davignon criteria for ECG waves overestimate LVH in children presenting with syncope, and to study the usefulness of echocardiography in these children. We hypothesize that the Davignon criteria presently used for interpretation of ECGs overestimate LVH, resulting in unnecessary echocardiography in this clinical setting. The clinical database of The Children's Hospital of Philadelphia was evaluated from 2002 to 2012 to identify children between 9 and 16 years of age, who presented with non-exercise-induced, isolated syncope. From this group of patients, only those with clear-cut evidence of LVH (by Davignon criteria), who also underwent an echocardiogram, were selected. A total of 136 children with syncope were identified as having LVH by Davignon ECG criteria. None of these patients manifested any evidence of hypertrophic cardiomyopathy, with normal ventricular septum (average Z-score -0.68 ± 0.84), LV posterior wall (average Z-score -0.66 ± 1.18) and LV mass (average Z-score 0.52 ± 1.29). No significant correlation was found between summed RV6 plus SV1 and LV mass. Correlations between additional ECG parameters and measures of LVH by echocardiography were similarly poor. In children presenting with syncope and LVH by ECG, there was no evidence of true LVH by echocardiography. We propose that the Davignon ECG criteria for interpreting LVH in children overestimate the degree of hypertrophy in these children and the yield of echocardiography is extremely low.

  3. Closed-Loop Control of Humidification for Artifact Reduction in Capacitive ECG Measurements.

    Science.gov (United States)

    Leicht, Lennart; Eilebrecht, Benjamin; Weyer, Soren; Leonhardt, Steffen; Teichmann, Daniel

    2017-04-01

    Recording biosignals without the need for direct skin contact offers new opportunities for ubiquitous health monitoring. Electrodes with capacitive coupling have been shown to be suitable for the monitoring of electrical potentials on the body surface, in particular ECG. However, due to triboelectric charge generation and motion artifacts, signal and thus diagnostic quality is inferior to galvanic coupling. Active closed-loop humidification of capacitive electrodes is proposed in this work as a new concept to improve signal quality. A capacitive ECG recording system integrated into a common car seat is presented. It can regulate the micro climate at the interface of electrode and patient by actively dispensing water vapour and monitoring humidity in a closed-loop approach. As a regenerative water reservoir, silica gel is used. The system was evaluated with respect to subjective and objective ECG signal quality. Active humidification was found to have a significant positive effect in case of previously poor quality. Also, it had no diminishing effect in case of already good signal quality.

  4. Investigating the effect of traditional Persian music on ECG signals in young women using wavelet transform and neural networks.

    Science.gov (United States)

    Abedi, Behzad; Abbasi, Ataollah; Goshvarpour, Atefeh

    2017-05-01

    In the past few decades, several studies have reported the physiological effects of listening to music. The physiological effects of different music types on different people are different. In the present study, we aimed to examine the effects of listening to traditional Persian music on electrocardiogram (ECG) signals in young women. Twenty-two healthy females participated in this study. ECG signals were recorded under two conditions: rest and music. For each ECG signal, 20 morphological and wavelet-based features were selected. Artificial neural network (ANN) and probabilistic neural network (PNN) classifiers were used for the classification of ECG signals during and before listening to music. Collected data were separated into two data sets: train and test. Classification accuracies of 88% and 97% were achieved in train data sets using ANN and PNN, respectively. In addition, the test data set was employed for evaluating the classifiers, and classification rates of 84% and 93% were obtained using ANN and PNN, respectively. The present study investigated the effect of music on ECG signals based on wavelet transform and morphological features. The results obtained here can provide a good understanding on the effects of music on ECG signals to researchers.

  5. The Comparative Study of ECG Findings in the Patients Suffered from Subarachnoid Hemorrhage and Control Group in Northeastern Iran

    Directory of Open Access Journals (Sweden)

    Karim Nikkhah

    2015-04-01

    Full Text Available Introduction: Subarachnoid Hemorrhage (SAH which accounts for (5% to 10% of cerebrovascular accidents is an important cause of mortality and disability. It can be complicated by many neurological and medical conditions including cardiovascular complications. During the course of SAH morphologic Electrocardiography (ECG changes, arrhythmias, myocardial injury and elevation of cardiac enzymes, subendocardial hemorrhage and necrosis may be observed. Materials and Methods:102 SAH patients, without any history of Ischemic heart Disease (IHD, admitted in Ghaem Hospital were studied. Their clinical and radiological parameters were evaluated. Three serial ECGs were performed within the first 72 hours for each patient and the ECG findings were analyzed. The control group consisted of 102 elective patients of Ghaem hospital without any expected heart disease. Results: ECG changes were observed in 60.8% of SAH patients with average age of (53.4±14.2 years and in (2.9% of control group. The ECG findings were as follows: chamber abnormalities (6.9%, conduction abnormalities (7.8%, repolarization abnormalities (49%, rhythm abnormalities (22.5% and pathologic Q wave (6.9%. According to this study, ECG changes are related to subarachnoid hemorrhage (p

  6. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    Science.gov (United States)

    Schwemmer, C.; Rohkohl, C.; Lauritsch, G.; Müller, K.; Hornegger, J.

    2013-06-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D-2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average.

  7. Mobile Cloud-Computing-Based Healthcare Service by Noncontact ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Ee-May Fong

    2013-12-01

    Full Text Available Noncontact electrocardiogram (ECG measurement technique has gained popularity these days owing to its noninvasive features and convenience in daily life use. This paper presents mobile cloud computing for a healthcare system where a noncontact ECG measurement method is employed to capture biomedical signals from users. Healthcare service is provided to continuously collect biomedical signals from multiple locations. To observe and analyze the ECG signals in real time, a mobile device is used as a mobile monitoring terminal. In addition, a personalized healthcare assistant is installed on the mobile device; several healthcare features such as health status summaries, medication QR code scanning, and reminders are integrated into the mobile application. Health data are being synchronized into the healthcare cloud computing service (Web server system and Web server dataset to ensure a seamless healthcare monitoring system and anytime and anywhere coverage of network connection is available. Together with a Web page application, medical data are easily accessed by medical professionals or family members. Web page performance evaluation was conducted to ensure minimal Web server latency. The system demonstrates better availability of off-site and up-to-the-minute patient data, which can help detect health problems early and keep elderly patients out of the emergency room, thus providing a better and more comprehensive healthcare cloud computing service.

  8. Low flip angle spin-echo MR imaging to obtain better Gd-DTPA enhanced imaging with ECG gating

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Kawamitsu, Hideaki; Yoshikawa, Kazuaki; Kasai, Toshifumi; Yuasa, Koji; Ishida, Tetsuya

    1992-01-01

    ECG-gated spin-echo imaging (ECG-SE) can reduce physiological motion artifact. However, ECG-SE does not provide strong T1-weighted images because repetition time (TR) depends on heart rate (HR). We investigated the usefulness of low flip angle spin-echo imaging (LFSE) in obtaining more T1-dependent contrast with ECG gating. In computer simulation, the predicted image contrast and single-to-noise ratio (SNR) obtained for each flip angle (0-180deg) and each TR (300 msec-1200 msec) were compared with those obtained by conventional T1-weighted spin-echo imaging (CSE: TR=500 msec, TE=20 msec). In clinical evaluation, tissue contrast [contrast index (CI): (SI of lesion-SI of muslce) 2* 100/SI of muscle] obtained by CSE and LFSE were compared in 17 patients. At a TR of 1,000 msec, T1-dependent contrast increased with decreasing flip angle and that at 38deg was identical to that with T1-weighted spin-echo. SNR increased with the flip angle until 100deg, and that at 53deg was identical to that with T1-weighted spin-echo. CI on LFSE (74.0±52.0) was significantly higher than CI on CSE (40.9±35.9). ECG-gated LFSE imaging provides better T1-dependent contrast than conventional ECG-SE. This method was especially useful for Gd-DTPA enhanced MR imaging. (author)

  9. Pseudo-real-time low-pass filter in ECG, self-adjustable to the frequency spectra of the waves.

    Science.gov (United States)

    Christov, Ivaylo; Neycheva, Tatyana; Schmid, Ramun; Stoyanov, Todor; Abächerli, Roger

    2017-09-01

    The electrocardiogram (ECG) acquisition is often accompanied by high-frequency electromyographic (EMG) noise. The noise is difficult to be filtered, due to considerable overlapping of its frequency spectrum to the frequency spectrum of the ECG. Today, filters must conform to the new guidelines (2007) for low-pass filtering in ECG with cutoffs of 150 Hz for adolescents and adults, and to 250 Hz for children. We are suggesting a pseudo-real-time low-pass filter, self-adjustable to the frequency spectra of the ECG waves. The filter is based on the approximation procedure of Savitzky-Golay with dynamic change in the cutoff frequency. The filter is implemented pseudo-real-time (real-time with a certain delay). An additional option is the automatic on/off triggering, depending on the presence/absence of EMG noise. The analysis of the proposed filter shows that the low-frequency components of the ECG (low-power P- and T-waves, PQ-, ST- and TP-segments) are filtered with a cutoff of 14 Hz, the high-power P- and T-waves are filtered with a cutoff frequency in the range of 20-30 Hz, and the high-frequency QRS complexes are filtered with cutoff frequency of higher than 100 Hz. The suggested dynamic filter satisfies the conflicting requirements for a strong suppression of EMG noise and at the same time a maximal preservation of the ECG high-frequency components.

  10. Endemic versus epidemic viral spreads display distinct patterns of HTLV-2b replication

    International Nuclear Information System (INIS)

    Gabet, Anne-Sophie; Moules, Vincent; Sibon, David; Nass, Catharie C.; Mortreux, Franck; Mauclere, Philippe; Gessain, Antoine; Murphy, Edward L.; Wattel, Eric

    2006-01-01

    As the replication pattern of leukemogenic PTLVs possesses a strong pathogenic impact, we investigated HTLV-2 replication in vivo in asymptomatic carriers belonging into 2 distinct populations infected by the same HTLV-2b subtype. They include epidemically infected American blood donors, in whom HTLV-2b has been present for only 30 years, and endemically infected Bakola Pygmies from Cameroon, characterized by a long viral endemicity (at least few generations). In blood donors, both the circulating proviral loads and the degree of infected cell proliferation were largely lower than those characterizing asymptomatic carriers infected with leukemogenic PTLVs (HTLV-1, STLV-1). This might contribute to explain the lack of known link between HTLV-2b infection and the development of malignancies in this population. In contrast, endemically infected individuals displayed high proviral loads resulting from the extensive proliferation of infected cells. The route and/or the duration of infection, viral genetic drift, host immune response, genetic background, co-infections or a combination thereof might have contributed to these differences between endemically and epidemically infected subjects. As the clonality pattern observed in endemically infected individuals is very reminiscent of that of leukemogenic PTLVs at the pre-leukemic stage, our results highlight the possible oncogenic effect of HTLV-2b infection in such population

  11. Distinct perfusion patterns in Alzheimer's disease, frontotemporal dementia and dementia with Lewy bodies

    International Nuclear Information System (INIS)

    Binnewijzend, Maja A.A.; Wattjes, Mike P.; Berckel, Bart N.M. van; Barkhof, Frederik; Kuijer, Joost P.A.; Flier, Wiesje M. van der; Benedictus, Marije R.; Moeller, Christiane M.; Pijnenburg, Yolande A.L.; Lemstra, Afina W.; Prins, Niels D.; Scheltens, Philip

    2014-01-01

    To compare pseudo-continuous arterial spin-labelled (PCASL) magnetic resonance imaging (MRI) measured quantitative cerebral blood flow (CBF) of patients with frontotemporal dementia (FTD), dementia with Lewy Bodies (DLB), Alzheimer's disease (AD) and controls, in a region of interest (ROI) and voxel-wise fashion. We analysed whole-brain 3D fast-spin-echo PCASL images of 20 FTD patients, 14 DLB patients, 48 AD patients and 50 controls from the Amsterdam Dementia Cohort. Regional CBF patterns were compared using analyses of variance for repeated measures. Permutation tests were used for voxel-wise comparisons. Analyses were performed using uncorrected and partial volume corrected (PVC) maps. All analyses were corrected for age and sex. There was an interaction between diagnosis and region (p < 0.001), implying differences in regional CBF changes between diagnostic groups. In AD patients, CBF was decreased in all supratentorial regions, most prominently so in the posterior regions. DLB patients showed lowest CBF values throughout the brain, but temporal CBF was preserved. Supratentorial PVC cortical CBF values were lowest in the frontal lobes in FTD patients, and in the temporal lobes in AD patients. Patients with AD, FTD and DLB display distinct patterns of quantitative regional CBF changes. 3D-PCASL may provide additional value in the workup of dementia patients. (orig.)

  12. ECG-derived respiration methods: adapted ICA and PCA.

    Science.gov (United States)

    Tiinanen, Suvi; Noponen, Kai; Tulppo, Mikko; Kiviniemi, Antti; Seppänen, Tapio

    2015-05-01

    Respiration is an important signal in early diagnostics, prediction, and treatment of several diseases. Moreover, a growing trend toward ambulatory measurements outside laboratory environments encourages developing indirect measurement methods such as ECG derived respiration (EDR). Recently, decomposition techniques like principal component analysis (PCA), and its nonlinear version, kernel PCA (KPCA), have been used to derive a surrogate respiration signal from single-channel ECG. In this paper, we propose an adapted independent component analysis (AICA) algorithm to obtain EDR signal, and extend the normal linear PCA technique based on the best principal component (PC) selection (APCA, adapted PCA) to improve its performance further. We also demonstrate that the usage of smoothing spline resampling and bandpass-filtering improve the performance of all EDR methods. Compared with other recent EDR methods using correlation coefficient and magnitude squared coherence, the proposed AICA and APCA yield a statistically significant improvement with correlations 0.84, 0.82, 0.76 and coherences 0.90, 0.91, 0.85 between reference respiration and AICA, APCA and KPCA, respectively. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. The application of root mean square electrocardiography (RMS ECG) for the detection of acquired and congenital long QT syndrome.

    Science.gov (United States)

    Lux, Robert L; Sower, Christopher Todd; Allen, Nancy; Etheridge, Susan P; Tristani-Firouzi, Martin; Saarel, Elizabeth V

    2014-01-01

    Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS). RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II. All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3. These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements.

  14. Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy

    Directory of Open Access Journals (Sweden)

    Istvan Peterfi

    2014-01-01

    Full Text Available Objective. The aim of the study was to develop a complex electrophysiological measurement system (hardware and software which uses the methods of electrophysiology and provides significant information about the intrauterine status of the fetus, intending to obtain true-to-form, morphologically evaluated fetal ECG from transabdominal maternal lead. Results. The present method contains many novel ideas that allow creating true-to-form noninvasive fetal ECG in the third trimester of the pregnancy in 80% of the cases. Such ideas are the telemetric data collection, the “cleanse” of the real time recording from the maternal ECG, and the use of the cardiotocograph (CTG that allows identifying the fetal heart events. The advantage of this developed system is that it does not require any qualified staff, because both the extraction of the information from the abdominal recording and the processing of the data are automatic. Discussion. Although the idea of a noninvasive fetal electrocardiography is more than 100 years old still there is no simple, effective, and cheap method available that would enable an extensive use. This developed system can be used in the third trimester of the pregnancy efficiently. It can produce true-to-form fetal ECGs with amplitude less than 10 µV.

  15. Common and distinct patterns of grey-matter volume alteration in major depression and bipolar disorder: evidence from voxel-based meta-analysis.

    Science.gov (United States)

    Wise, T; Radua, J; Via, E; Cardoner, N; Abe, O; Adams, T M; Amico, F; Cheng, Y; Cole, J H; de Azevedo Marques Périco, C; Dickstein, D P; Farrow, T F D; Frodl, T; Wagner, G; Gotlib, I H; Gruber, O; Ham, B J; Job, D E; Kempton, M J; Kim, M J; Koolschijn, P C M P; Malhi, G S; Mataix-Cols, D; McIntosh, A M; Nugent, A C; O'Brien, J T; Pezzoli, S; Phillips, M L; Sachdev, P S; Salvadore, G; Selvaraj, S; Stanfield, A C; Thomas, A J; van Tol, M J; van der Wee, N J A; Veltman, D J; Young, A H; Fu, C H; Cleare, A J; Arnone, D

    2017-10-01

    Finding robust brain substrates of mood disorders is an important target for research. The degree to which major depression (MDD) and bipolar disorder (BD) are associated with common and/or distinct patterns of volumetric changes is nevertheless unclear. Furthermore, the extant literature is heterogeneous with respect to the nature of these changes. We report a meta-analysis of voxel-based morphometry (VBM) studies in MDD and BD. We identified studies published up to January 2015 that compared grey matter in MDD (50 data sets including 4101 individuals) and BD (36 data sets including 2407 individuals) using whole-brain VBM. We used statistical maps from the studies included where available and reported peak coordinates otherwise. Group comparisons and conjunction analyses identified regions in which the disorders showed common and distinct patterns of volumetric alteration. Both disorders were associated with lower grey-matter volume relative to healthy individuals in a number of areas. Conjunction analysis showed smaller volumes in both disorders in clusters in the dorsomedial and ventromedial prefrontal cortex, including the anterior cingulate cortex and bilateral insula. Group comparisons indicated that findings of smaller grey-matter volumes relative to controls in the right dorsolateral prefrontal cortex and left hippocampus, along with cerebellar, temporal and parietal regions were more substantial in major depression. These results suggest that MDD and BD are characterised by both common and distinct patterns of grey-matter volume changes. This combination of differences and similarities has the potential to inform the development of diagnostic biomarkers for these conditions.

  16. Amnesia, rehearsal, and temporal distinctiveness models of recall.

    Science.gov (United States)

    Brown, Gordon D A; Della Sala, Sergio; Foster, Jonathan K; Vousden, Janet I

    2007-04-01

    Classical amnesia involves selective memory impairment for temporally distant items in free recall (impaired primacy) together with relative preservation of memory for recency items. This abnormal serial position curve is traditionally taken as evidence for a distinction between different memory processes, with amnesia being associated with selectively impaired long-term memory. However recent accounts of normal serial position curves have emphasized the importance of rehearsal processes in giving rise to primacy effects and have suggested that a single temporal distinctiveness mechanism can account for both primacy and recency effects when rehearsal is considered. Here we explore the pattern of strategic rehearsal in a patient with very severe amnesia. When the patient's rehearsal pattern is taken into account, a temporal distinctiveness model can account for the serial position curve in both amnesic and control free recall. The results are taken as consistent with temporal distinctiveness models of free recall, and they motivate an emphasis on rehearsal patterns in understanding amnesic deficits in free recall.

  17. V–V delay interval optimization in CRT using echocardiography compared to QRS width in surface ECG

    Directory of Open Access Journals (Sweden)

    Amr Nawar

    2012-09-01

    Conclusion: Significant correlation appeared to exist during optimization of CRT between VV programming based on the shortest QRS interval at 12-lead ECG pacing and that based on highest LVOT VTI by echocardiography. A combined ECG and echocardiographic approach could be a more convenient solution in performing V–V optimization.

  18. Tc-99m Glu-Cys-Gly-His-Gly-Lys (ECG-HGK), a novel Tc-99m labeled hexapeptide for molecular tumor imaging.

    Science.gov (United States)

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    Domain 5 of kinin-free high molecular weight kininogen inhibits the adhesion of many tumor cell lines, and it has been reported that the histidine-glycine-lysine (HGK)-rich region might be responsible for inhibition of cell adhesion. The authors developed HGK-containing hexapeptide, glutamic acid-cysteine-glycine (ECG)-HGK, and evaluated the utility of Tc-99m ECG-HGK for tumor imaging. Hexapeptide, ECG-HGK was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling efficiency was evaluated. The uptake of Tc-99m ECG-HGK within HT-1080 cells was evaluated in vitro. In HT-1080 tumor-bearing mice, gamma imaging and biodistribution studies were performed. The complexes Tc-99m ECG-HGK was prepared in high yield. The uptake of Tc-99m ECG-HGK within the HT-1080 tumor cells had been demonstrated by in vitro studies. The gamma camera imaging in the murine model showed that Tc-99m ECG-HGK was accumulated substantially in the HT-1080 tumor (tumor-to-muscle ratio = 5.7 ± 1.4 at 4 h), and the tumoral uptake was blocked by the co-injection of excess HGK (tumor-to-muscle ratio = 2.8 ± 0.6 at 4 h). In the present study, Tc-99m ECG-HGK was developed as a new tumor imaging agents. Our in vitro and in vivo studies revealed specific function of Tc-99m ECG-HGK for tumor imaging. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Gustatory stimuli representing different perceptual qualities elicit distinct patterns of neuropeptide secretion from taste buds.

    Science.gov (United States)

    Geraedts, Maartje C P; Munger, Steven D

    2013-04-24

    Taste stimuli that evoke different perceptual qualities (e.g., sweet, umami, bitter, sour, salty) are detected by dedicated subpopulations of taste bud cells that use distinct combinations of sensory receptors and transduction molecules. Here, we report that taste stimuli also elicit unique patterns of neuropeptide secretion from taste buds that are correlated with those perceptual qualities. We measured tastant-dependent secretion of glucagon-like peptide-1 (GLP-1), glucagon, and neuropeptide Y (NPY) from circumvallate papillae of Tas1r3(+/+), Tas1r3(+/-) and Tas1r3 (-/-) mice. Isolated tongue epithelia were mounted in modified Ussing chambers, permitting apical stimulation of taste buds; secreted peptides were collected from the basal side and measured by specific ELISAs. Appetitive stimuli (sweet: glucose, sucralose; umami: monosodium glutamate; polysaccharide: Polycose) elicited GLP-1 and NPY secretion and inhibited basal glucagon secretion. Sweet and umami stimuli were ineffective in Tas1r3(-/-) mice, indicating an obligatory role for the T1R3 subunit common to the sweet and umami taste receptors. Polycose responses were unaffected by T1R3 deletion, consistent with the presence of a distinct polysaccharide taste receptor. The effects of sweet stimuli on peptide secretion also required the closing of ATP-sensitive K(+) (KATP) channels, as the KATP channel activator diazoxide inhibited the effects of glucose and sucralose on both GLP-1 and glucagon release. Both sour citric acid and salty NaCl increased NPY secretion but had no effects on GLP-1 or glucagon. Bitter denatonium showed no effects on these peptides. Together, these results suggest that taste stimuli of different perceptual qualities elicit unique patterns of neuropeptide secretion from taste buds.

  20. Distinct RNA transcriptome patterns are potentially associated with angiogenesis in Tie2-expressing monocytes.

    Science.gov (United States)

    Wang, Xinjing; Dai, Zhiyuan; Wu, Xiaoli; Wang, Kai; Wang, Xipeng

    2016-04-10

    Tie2-expressing Monocytes (TEMs) were previously identified as a novel subset of monocytes and were believed to have prominent pro-angiogenesis activities in human tumors. While the molecular mechanism of the angiogenesis promoting capacity of TEMs remains unclear. RNA transcriptome pattern, including non-coding RNAs as microRNA (miRNA) and long non-coding RNA (lncRNA), plays important role in cell differentiation and functions. However, little is known about the transcriptome patterns of TEMs, including those non-coding RNAs. We explore the transcriptome of TEMs and the matched monocytes that do not express Tie2 (Tie2(-)monocytes) isolated from peripheral blood of healthy adults employing the Agilent Human miRNA(8*60K,Design ID: 046064)microarray and the Agilent lncRNA Gene Expression(4*180K, Design ID: 042818)microarray. A total of 141 mRNAs, 142 lncRNAs and 75 miRNAs were found dysregulated in TEMs compared to Tie2(-)monocytes. TEMs have the distinct RNA transcriptome patterns according to the Hierarchical clustering and then the gene expression patterns were confirmed by quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR). Functional annotation by Gene Ontology (GO) analyses showed that the up-regulated mRNAs in TEMs were associated to blood vessel remodeling and positive regulation of epithelial cell proliferation, and the up-regulated insulin like growth factor 1(IGF1) mRNA was involved in both pathways. For functional analysis of those dysregulated non-coding RNAs, target genes of the miRNAs were predicted and cis/trans-regulation analysis of the lncRNAs were performed. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Improving the Lung Delivery of Nasally Administered Aerosols During Noninvasive Ventilation—An Application of Enhanced Condensational Growth (ECG)

    Science.gov (United States)

    Tian, Geng; Hindle, Michael

    2011-01-01

    Abstract Background Aerosol drug delivery during noninvasive ventilation (NIV) is known to be inefficient due to high depositional losses. To improve drug delivery efficiency, the concept of enhanced condensational growth (ECG) was recently proposed in which a submicrometer or nanoaerosol reduces extrathoracic deposition and subsequent droplet size increase promotes lung retention. The objective of this study was to provide proof-of-concept that the ECG approach could improve lung delivery of nasally administered aerosols under conditions consistent with NIV. Methods Aerosol deposition and size increase were evaluated in an adult nose–mouth–throat (NMT) replica geometry using both in vitro experiments and CFD simulations. For the ECG delivery approach, separate streams of a submicrometer aerosol and warm (39°C) saturated air were generated and delivered to the right and left nostril inlets, respectively. A control case was also considered in which an aerosol with a mass median aerodynamic diameter (MMAD) of 4.67 μm was delivered to the model. Results In vitro experiments showed that the ECG approach significantly reduced the drug deposition fraction in the NMT geometry compared with the control case [14.8 (1.83)%—ECG vs. 72.6 (3.7)%—control]. Aerosol size increased from an initial MMAD of 900 nm to a size of approximately 2 μm at the exit of the NMT geometry. Results of the CFD model were generally in good agreement with the experimental findings. Based on CFD predictions, increasing the delivery temperature of the aerosol stream from 21 to 35°C under ECG conditions further reduced the total NMT drug deposition to 5% and maintained aerosol growth by ECG to approximately 2 μm. Conclusions Application of the ECG approach may significantly improve the delivery of pharmaceutical aerosols during NIV and may open the door for using the nasal route to routinely deliver pulmonary medications. PMID:21410327

  2. Distinct patterns of brain activity characterise lexical activation and competition in spoken word production.

    Directory of Open Access Journals (Sweden)

    Vitória Piai

    Full Text Available According to a prominent theory of language production, concepts activate multiple associated words in memory, which enter into competition for selection. However, only a few electrophysiological studies have identified brain responses reflecting competition. Here, we report a magnetoencephalography study in which the activation of competing words was manipulated by presenting pictures (e.g., dog with distractor words. The distractor and picture name were semantically related (cat, unrelated (pin, or identical (dog. Related distractors are stronger competitors to the picture name because they receive additional activation from the picture relative to other distractors. Picture naming times were longer with related than unrelated and identical distractors. Phase-locked and non-phase-locked activity were distinct but temporally related. Phase-locked activity in left temporal cortex, peaking at 400 ms, was larger on unrelated than related and identical trials, suggesting differential activation of alternative words by the picture-word stimuli. Non-phase-locked activity between roughly 350-650 ms (4-10 Hz in left superior frontal gyrus was larger on related than unrelated and identical trials, suggesting differential resolution of the competition among the alternatives, as reflected in the naming times. These findings characterise distinct patterns of activity associated with lexical activation and competition, supporting the theory that words are selected by competition.

  3. Parametric modelling of cardiac system multiple measurement signals: an open-source computer framework for performance evaluation of ECG, PCG and ABP event detectors.

    Science.gov (United States)

    Homaeinezhad, M R; Sabetian, P; Feizollahi, A; Ghaffari, A; Rahmani, R

    2012-02-01

    The major focus of this study is to present a performance accuracy assessment framework based on mathematical modelling of cardiac system multiple measurement signals. Three mathematical algebraic subroutines with simple structural functions for synthetic generation of the synchronously triggered electrocardiogram (ECG), phonocardiogram (PCG) and arterial blood pressure (ABP) signals are described. In the case of ECG signals, normal and abnormal PQRST cycles in complicated conditions such as fascicular ventricular tachycardia, rate dependent conduction block and acute Q-wave infarctions of inferior and anterolateral walls can be simulated. Also, continuous ABP waveform with corresponding individual events such as systolic, diastolic and dicrotic pressures with normal or abnormal morphologies can be generated by another part of the model. In addition, the mathematical synthetic PCG framework is able to generate the S4-S1-S2-S3 cycles in normal and in cardiac disorder conditions such as stenosis, insufficiency, regurgitation and gallop. In the PCG model, the amplitude and frequency content (5-700 Hz) of each sound and variation patterns can be specified. The three proposed models were implemented to generate artificial signals with varies abnormality types and signal-to-noise ratios (SNR), for quantitative detection-delineation performance assessment of several ECG, PCG and ABP individual event detectors designed based on the Hilbert transform, discrete wavelet transform, geometric features such as area curve length (ACLM), the multiple higher order moments (MHOM) metric, and the principal components analysed geometric index (PCAGI). For each method the detection-delineation operating characteristics were obtained automatically in terms of sensitivity, positive predictivity and delineation (segmentation) error rms and checked by the cardiologist. The Matlab m-file script of the synthetic ECG, ABP and PCG signal generators are available in the Appendix.

  4. hESC Differentiation toward an Autonomic Neuronal Cell Fate Depends on Distinct Cues from the Co-Patterning Vasculature

    Directory of Open Access Journals (Sweden)

    Lisette M. Acevedo

    2015-06-01

    Full Text Available To gain insight into the cellular and molecular cues that promote neurovascular co-patterning at the earliest stages of human embryogenesis, we developed a human embryonic stem cell model to mimic the developing epiblast. Contact of ectoderm-derived neural cells with mesoderm-derived vasculature is initiated via the neural crest (NC, not the neural tube (NT. Neurovascular co-patterning then ensues with specification of NC toward an autonomic fate requiring vascular endothelial cell (EC-secreted nitric oxide (NO and direct contact with vascular smooth muscle cells (VSMCs via T-cadherin-mediated homotypic interactions. Once a neurovascular template has been established, NT-derived central neurons then align themselves with the vasculature. Our findings reveal that, in early human development, the autonomic nervous system forms in response to distinct molecular cues from VSMCs and ECs, providing a model for how other developing lineages might coordinate their co-patterning.

  5. How to Diagnose and Classify Tattoo Complications in the Clinic: A System of Distinctive Patterns.

    Science.gov (United States)

    Serup, Jørgen

    2017-01-01

    Tattoo complications represent a broad spectrum of clinical entities and disease mechanisms. Infections are known, but chronic inflammatory reactions have hitherto been inconsistently reported and given many interpretations and terms. A clinical classification system of distinct patterns with emphasis on inflammatory tattoo reactions is introduced. Allergic reactions prevalent in red tattoos and often associated with azo pigments are manifested as the 'plaque elevation', 'excessive hyperkeratosis', and 'ulceronecrotic' patterns. The allergen is a hapten. Nonallergic reactions prevalent in black tattoos and associated with carbon black are manifested as the 'papulonodular' pattern. Carbon black nanoparticles agglomerate in the dermis over time forming foreign bodies that elicit reactions. Many black tattoos even develop sarcoid granuloma, and the 'papulonodular' pattern is strongly associated with sarcoidosis affecting other organs. Tattoo complications include a large group of less frequent but nevertheless specific entities, i.e. irritant and toxic local events, photosensitivity, urticaria, eczematous rash due to soluble allergen, neurosensitivity and pain syndrome, lymphopathies, pigment diffusion or fan, scars, and other sequels of tattooing or tattoo removal. Keratoacanthoma occurs in tattoos. Carcinoma and melanoma are rare and occur by coincidence only. Different tattoo complications require different therapeutic approaches, and precise diagnosis is thus important as a key to therapy. The proposed new classification with characteristic patterns relies on simple tools, namely patient history, objective findings, and supplementary punch biopsy. By virtue of simplicity and broad access, these methods make the proposed classification widely applicable in clinics and hospitals. The system is reported to the 11th revision of the WHO diagnosis classification used as international standard. © 2017 S. Karger AG, Basel.

  6. Evaluation of Digital Compressed Sensing for Real-Time Wireless ECG System with Bluetooth low Energy.

    Science.gov (United States)

    Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan

    2016-07-01

    In this paper, a wearable and wireless ECG system is firstly designed with Bluetooth Low Energy (BLE). It can detect 3-lead ECG signals and is completely wireless. Secondly the digital Compressed Sensing (CS) is implemented to increase the energy efficiency of wireless ECG sensor. Different sparsifying basis, various compression ratio (CR) and several reconstruction algorithms are simulated and discussed. Finally the reconstruction is done by the android application (App) on smartphone to display the signal in real time. The power efficiency is measured and compared with the system without CS. The optimum satisfying basis built by 3-level decomposed db4 wavelet coefficients, 1-bit Bernoulli random matrix and the most suitable reconstruction algorithm are selected by the simulations and applied on the sensor node and App. The signal is successfully reconstructed and displayed on the App of smartphone. Battery life of sensor node is extended from 55 h to 67 h. The presented wireless ECG system with CS can significantly extend the battery life by 22 %. With the compact characteristic and long term working time, the system provides a feasible solution for the long term homecare utilization.

  7. Telemetry-assisted early detection of STEMI in patients with atypical symptoms by paramedic-performed 12-lead ECG with subsequent cardiological analysis.

    Science.gov (United States)

    Campo Dell' Orto, Marco; Hamm, Christian; Liebetrau, Christoph; Hempel, Dorothea; Merbs, Reinhold; Cuca, Colleen; Breitkreutz, Raoul

    2017-08-01

    ECG is an essential diagnostic tool in patients with acute coronary syndrome. We aimed to determine how many patients presenting with atypical symptoms for an acute myocardial infarction show ST-segment elevations on prehospital ECG. We also aimed to study the feasibility of telemetric-assisted prehospital ECG analysis. Between April 2010 and February 2011, consecutive emergency patients presenting with atypical symptoms such as nausea, vomiting, atypical chest pain, palpitations, hypertension, syncope, or dizziness were included in the study. After basic measures were completed, a 12-lead ECG was written and telemetrically transmitted to the cardiac center, where it was analyzed by attending physicians. Any identification of an ST-elevation myocardial infarction resulted in patient admission at the closest coronary angiography facility. A total of 313 emergency patients presented with the following symptoms: dyspnea, nausea, vomiting, dizziness/collapse, or acute hypertension. Thirty-four (11%) patients of this cohort were found to show ST-segment elevations on the 12-lead ECG. These patients were directly admitted to the closest coronary catheterization facility rather than the closest hospital. The time required for transmission and analysis of the ECG was 3.6±1.2 min. Telemetry-assisted 12-lead ECG analysis in a prehospital setting may lead to earlier detection of ST-elevation myocardial infarction in patients with atypical symptoms. Thus, a 12-lead ECG should be considered in all prehospital patients both with typical and atypical symptoms.

  8. High Resolution of the ECG Signal by Polynomial Approximation

    Directory of Open Access Journals (Sweden)

    G. Rozinaj

    2006-04-01

    Full Text Available Averaging techniques as temporal averaging and space averaging have been successfully used in many applications for attenuating interference [6], [7], [8], [9], [10]. In this paper we introduce interference removing of the ECG signal by polynomial approximation, with smoothing discrete dependencies, to make up for averaging methods. The method is suitable for low-level signals of the electrical activity of the heart often less than 10 m V. Most low-level signals arising from PR, ST and TP segments which can be detected eventually and their physiologic meaning can be appreciated. Of special importance for the diagnostic of the electrical activity of the heart is the activity bundle of His between P and R waveforms. We have established an artificial sine wave to ECG signal between P and R wave. The aim focus is to verify the smoothing method by polynomial approximation if the SNR (signal-to-noise ratio is negative (i.e. a signal is lower than noise.

  9. Distinct multivariate brain morphological patterns and their added predictive value with cognitive and polygenic risk scores in mental disorders

    Directory of Open Access Journals (Sweden)

    Nhat Trung Doan

    2017-01-01

    Full Text Available The brain underpinnings of schizophrenia and bipolar disorders are multidimensional, reflecting complex pathological processes and causal pathways, requiring multivariate techniques to disentangle. Furthermore, little is known about the complementary clinical value of brain structural phenotypes when combined with data on cognitive performance and genetic risk. Using data-driven fusion of cortical thickness, surface area, and gray matter density maps (GMD, we found six biologically meaningful patterns showing strong group effects, including four statistically independent multimodal patterns reflecting co-occurring alterations in thickness and GMD in patients, over and above two other independent patterns of widespread thickness and area reduction. Case-control classification using cognitive scores alone revealed high accuracy, and adding imaging features or polygenic risk scores increased performance, suggesting their complementary predictive value with cognitive scores being the most sensitive features. Multivariate pattern analyses reveal distinct patterns of brain morphology in mental disorders, provide insights on the relative importance between brain structure, cognitive and polygenetic risk score in classification of patients, and demonstrate the importance of multivariate approaches in studying the pathophysiological substrate of these complex disorders.

  10. ECG based Atrial Fibrillation detection using Sequency Ordered Complex Hadamard Transform and Hybrid Firefly Algorithm

    Directory of Open Access Journals (Sweden)

    Padmavathi Kora

    2017-06-01

    Full Text Available Electrocardiogram (ECG, a non-invasive diagnostic technique, used for detecting cardiac arrhythmia. From last decade industry dealing with biomedical instrumentation and research, demanding an advancement in its ability to distinguish different cardiac arrhythmia. Atrial Fibrillation (AF is an irregular rhythm of the human heart. During AF, the atrial moments are quicker than the normal rate. As blood is not completely ejected out of atria, chances for the formation of blood clots in atrium. These abnormalities in the heart can be identified by the changes in the morphology of the ECG. The first step in the detection of AF is preprocessing of ECG, which removes noise using filters. Feature extraction is the next key process in this research. Recent feature extraction methods, such as Auto Regressive (AR modeling, Magnitude Squared Coherence (MSC and Wavelet Coherence (WTC using standard database (MIT-BIH, yielded a lot of features. Many of these features might be insignificant containing some redundant and non-discriminatory features that introduce computational burden and loss of performance. This paper presents fast Conjugate Symmetric Sequency Ordered Complex Hadamard Transform (CS-SCHT for extracting relevant features from the ECG signal. The sparse matrix factorization method is used for developing fast and efficient CS-SCHT algorithm and its computational performance is examined and compared to that of the HT and NCHT. The applications of the CS-SCHT in the ECG-based AF detection is also discussed. These fast CS-SCHT features are optimized using Hybrid Firefly and Particle Swarm Optimization (FFPSO to increase the performance of the classifier.

  11. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul, E-mail: paul.stolzmann@usz.ch [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetti, Robert; Baumueller, Stephan [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Plass, Andre; Falk, Volkmar [Clinic for Cardiovascular Surgery, University Hospital Zurich (Switzerland); Scheffel, Hans; Feuchtner, Gudrun; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Alkadhi, Hatem [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Leschka, Sebastian [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2011-07-15

    Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates {<=}70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 {+-} 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 {+-} 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates {<=}70 bpm

  12. Development and validation of a novel algorithm based on the ECG magnet response for rapid identification of any unknown pacemaker.

    Science.gov (United States)

    Squara, Fabien; Chik, William W; Benhayon, Daniel; Maeda, Shingo; Latcu, Decebal Gabriel; Lacaze-Gadonneix, Jonathan; Tibi, Thierry; Thomas, Olivier; Cooper, Joshua M; Duthoit, Guillaume

    2014-08-01

    Pacemaker (PM) interrogation requires correct manufacturer identification. However, an unidentified PM is a frequent occurrence, requiring time-consuming steps to identify the device. The purpose of this study was to develop and validate a novel algorithm for PM manufacturer identification, using the ECG response to magnet application. Data on the magnet responses of all recent PM models (≤15 years) from the 5 major manufacturers were collected. An algorithm based on the ECG response to magnet application to identify the PM manufacturer was subsequently developed. Patients undergoing ECG during magnet application in various clinical situations were prospectively recruited in 7 centers. The algorithm was applied in the analysis of every ECG by a cardiologist blinded to PM information. A second blinded cardiologist analyzed a sample of randomly selected ECGs in order to assess the reproducibility of the results. A total of 250 ECGs were analyzed during magnet application. The algorithm led to the correct single manufacturer choice in 242 ECGs (96.8%), whereas 7 (2.8%) could only be narrowed to either 1 of 2 manufacturer possibilities. Only 2 (0.4%) incorrect manufacturer identifications occurred. The algorithm identified Medtronic and Sorin Group PMs with 100% sensitivity and specificity, Biotronik PMs with 100% sensitivity and 99.5% specificity, and St. Jude and Boston Scientific PMs with 92% sensitivity and 100% specificity. The results were reproducible between the 2 blinded cardiologists with 92% concordant findings. Unknown PM manufacturers can be accurately identified by analyzing the ECG magnet response using this newly developed algorithm. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Refined staging in hilar bronchial neoplasms with ECG-gated multislice-CT. Case report

    International Nuclear Information System (INIS)

    Ohlmann, S.; Daliri, A.; Froelich, J.J.; Nowak, R.; Michulla, R.

    2008-01-01

    Equivocal initial CT-based staging in 2 patients with hilar bronchial neoplasms was reassessed with retrospective ECG-gated Multislice-CT and optimized examination parameters prior to definition of treatment. An initially suspected irresectable T 4 tumor with mediastinal infiltration was downstaged to T 2 in one case, while tumor infiltration into the left atrium could be confirmed in the other case. In doubtful conditions, ECG-gated multislice CT with optimized examination parameters may be helpful for refined staging in patients with hilar bronchial neoplasma, thus possibly influencing treatment strategies. (orig.)

  14. Creating fair lineups for suspects with distinctive features.

    Science.gov (United States)

    Zarkadi, Theodora; Wade, Kimberley A; Stewart, Neil

    2009-12-01

    In their descriptions, eyewitnesses often refer to a culprit's distinctive facial features. However, in a police lineup, selecting the only member with the described distinctive feature is unfair to the suspect and provides the police with little further information. For fair and informative lineups, the distinctive feature should be either replicated across foils or concealed on the target. In the present experiments, replication produced more correct identifications in target-present lineups--without increasing the incorrect identification of foils in target-absent lineups--than did concealment. This pattern, and only this pattern, is predicted by the hybrid-similarity model of recognition.

  15. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    International Nuclear Information System (INIS)

    Schwemmer, C; Müller, K; Hornegger, J; Rohkohl, C; Lauritsch, G

    2013-01-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D–2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average. (paper)

  16. ECG and enzymatic indicators of therapeutic success after intravenous streptokinase for acute myocardial infarction

    DEFF Research Database (Denmark)

    Clemmensen, P; Grande, P; Pedersen, F

    1990-01-01

    Thrombolytic therapy has been documented to result in reperfusion of jeopardized myocardium and reduction in the size of the acute myocardial infarction (AMI). The effect of intravenous streptokinase on a creatine kinase-MB (CK-MB) reperfusion index and an ECG estimate of myocardial salvage...... was therefore studied in 65 patients with a first AMI, randomized to treatment with streptokinase (n = 33) or placebo (control group, n = 32). Reperfusion was defined as a CK-MB appearance rate constant (k1) greater than 0.185. The final AMI size was first predicted from the admission standard ECG by previously...... developed formulas based on ST segment elevation. The final AMI size was estimated from the QRS score on the predischarge ECG. Myocardial salvage was defined as a greater than or equal to 20% decrease from predicted to final AMI size. The k1 value in the control group was significantly lower than...

  17. Wavelet compression of multichannel ECG data by enhanced set partitioning in hierarchical trees algorithm.

    Science.gov (United States)

    Sharifahmadian, Ershad

    2006-01-01

    The set partitioning in hierarchical trees (SPIHT) algorithm is very effective and computationally simple technique for image and signal compression. Here the author modified the algorithm which provides even better performance than the SPIHT algorithm. The enhanced set partitioning in hierarchical trees (ESPIHT) algorithm has performance faster than the SPIHT algorithm. In addition, the proposed algorithm reduces the number of bits in a bit stream which is stored or transmitted. I applied it to compression of multichannel ECG data. Also, I presented a specific procedure based on the modified algorithm for more efficient compression of multichannel ECG data. This method employed on selected records from the MIT-BIH arrhythmia database. According to experiments, the proposed method attained the significant results regarding compression of multichannel ECG data. Furthermore, in order to compress one signal which is stored for a long time, the proposed multichannel compression method can be utilized efficiently.

  18. Distinct brain metabolic patterns separately associated with cognition, motor function, and aging in Parkinson's disease dementia.

    Science.gov (United States)

    Ko, Ji Hyun; Katako, Audrey; Aljuaid, Maram; Goertzen, Andrew L; Borys, Andrew; Hobson, Douglas E; Kim, Seok Min; Lee, Chong Sik

    2017-12-01

    We explored whether patients with Parkinson's disease dementia (PDD) show a distinct spatial metabolic pattern that characterizes cognitive deficits in addition to motor dysfunction. Eighteen patients with PDD underwent 3 separate positron emission tomography sessions with [ 18 F]fluorodeoxyglucose (for glucose metabolism), fluorinated N-3-fluoropropyl-2-beta-carboxymethoxy-3-beta-(4-iodophenyl) nortropane (for dopamine transporter density) and Pittsburgh compound-B (for beta-amyloid load). We confirmed in PDD versus normal controls, overall hypometabolism in the posterior and prefrontal brain regions accompanied with hypermetabolism in subcortical structures and the cerebellar vermis. A multivariate network analysis then revealed 3 metabolic patterns that are separately associated with cognitive performance (p = 0.042), age (p = 0.042), and motor symptom severity (p = 0.039). The age-related pattern's association with aging was replicated in healthy controls (p = 0.047) and patients with Alzheimer's disease (p = 0.002). The cognition-related pattern's association with cognitive performance was observed, with a trend-level of correlation, in patients with dementia with Lewy bodies (p = 0.084) but not in patients with Alzheimer's disease (p = 0.974). We found no association with fluorinated N-3-fluoropropyl-2-beta-carboxymethoxy-3-beta-(4-iodophenyl) nortropane and Pittsburgh compound-B positron emission tomography with patients' cognitive performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Wireless ECG and PCG Portable Telemedicine Kit for Rural Areas of Colombia

    Directory of Open Access Journals (Sweden)

    Miguel Jimeno

    2014-07-01

    Full Text Available Telemedicine is always a popular topic thanks to the constants advancements of technology. The focus on development of new devices has been mainly on decreasing size to increase portability. Our research focused on improving functionality but not giving up on portability and cost. In this paper we are presenting the first prototype device that measures 4-leads electrocardiogram (ECG and phonocardiogram (PCG signals with low cost, high portability and wireless connectivity features in mind. We designed and developed a prototype that measures ECG using a standard ECG cable; we designed and developed a digital stethoscope prototype and also the necessary hardware for both medical signals to be transmitted through Bluetooth to a computer. We present here the hardware design, a new communication protocol for transmission of both signals from the device to the computer, and the software system to enable remote consultations. We designed the prototype with the main purpose of using low cost parts without sacrificing functionality, with the purpose of using it in remote zones of the Caribbean coast of Colombia. We show open issues and prepare a field implementation of the kit in the target zone.

  20. Graphite Based Electrode for ECG Monitoring: Evaluation under Freshwater and Saltwater Conditions

    Directory of Open Access Journals (Sweden)

    Tharoeun Thap

    2016-04-01

    Full Text Available We proposed new electrodes that are applicable for electrocardiogram (ECG monitoring under freshwater- and saltwater-immersion conditions. Our proposed electrodes are made of graphite pencil lead (GPL, a general-purpose writing pencil. We have fabricated two types of electrode: a pencil lead solid type (PLS electrode and a pencil lead powder type (PLP electrode. In order to assess the qualities of the PLS and PLP electrodes, we compared their performance with that of a commercial Ag/AgCl electrode, under a total of seven different conditions: dry, freshwater immersion with/without movement, post-freshwater wet condition, saltwater immersion with/without movement, and post-saltwater wet condition. In both dry and post-freshwater wet conditions, all ECG-recorded PQRST waves were clearly discernible, with all types of electrodes, Ag/AgCl, PLS, and PLP. On the other hand, under the freshwater- and saltwater-immersion conditions with/without movement, as well as post-saltwater wet conditions, we found that the proposed PLS and PLP electrodes provided better ECG waveform quality, with significant statistical differences compared with the quality provided by Ag/AgCl electrodes.

  1. Comparative study of image quality and radiation dose between prospective and retrospective ECG gating technique in coronary artery imaging with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Liu Jianxin; Liu Jian; Dou Yanbin; Wang Jichen; Sun Hongyue

    2009-01-01

    Objective: To compare the image quality and radiation dose between prospective ECG-trigering and retrospective ECG gating technique in coronary artery imaging. Methods: 33 patients suspected coronary artery disease were included in this study and divided into experimental group (prospective ECG-triggering coronary artery imaging, heart rate 0.05). The mean DLP of experimental group (234.4 mGy · cm) was DLP of control group (974.4 mGy · cm) 24.1%. The mean effective dose of prospective ECG gating coronary artery imaging was 3.2 mSv. Effective dose reduced 76.47 %. Conclusions: Prospective ECG gating coronary artery imaging can obtain the similar image quality compared with prospective ECG gating coronary artery imaging but the effective dose reduced 76.47 %. Prospective ECG gating coronary artery imaging has clinical value to peoples who are able to not accept high radiation dose and with low heart rate. (authors)

  2. A New Method to Detect Driver Fatigue Based on EMG and ECG Collected by Portable Non-Contact Sensors

    Directory of Open Access Journals (Sweden)

    Lin Wang

    2017-11-01

    Full Text Available Recently, detection and prediction on driver fatigue have become interest of research worldwide. In the present work, a new method is built to effectively evaluate driver fatigue based on electromyography (EMG and electrocardiogram (ECG collected by portable real-time and non-contact sensors. First, under the non-disturbance condition for driver’s attention, mixed physiological signals (EMG, ECG and artefacts are collected by non-contact sensors located in a cushion on the driver’s seat. EMG and ECG are effectively separated by FastICA, and de-noised by empirical mode decomposition (EMD. Then, three physiological features, complexity of EMG, complexity of ECG, and sample entropy (SampEn of ECG, are extracted and analysed. Principal components are obtained by principal components analysis (PCA and are used as independent variables. Finally, a mathematical model of driver fatigue is built, and the accuracy of the model is up to 91%. Moreover, based on the questionnaire, the calculation results of model are consistent with real fatigue felt by the participants. Therefore, this model can effectively detect driver fatigue.

  3. Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

    Directory of Open Access Journals (Sweden)

    Dragoş-Daniel Ţarălungă

    2014-01-01

    Full Text Available Interference of power line (PLI (fundamental frequency and its harmonics is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG, electroencephalograms (EEG, and electrocardiograms (ECG. When analyzing the fetal ECG (fECG recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios, based on five quantitative performance indices.

  4. Fetal ECG extraction from abdominal signals: a review on suppression of fundamental power line interference component and its harmonics.

    Science.gov (United States)

    Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner

    2014-01-01

    Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices.

  5. Performance of short ECG recordings twice daily to detect paroxysmal atrial fibrillation in stroke and transient ischemic attack patients

    DEFF Research Database (Denmark)

    Poulsen, Mai Bang; Binici, Zeynep; Domínguez, Helena

    2017-01-01

    Aims Prolonged cardiac monitoring after stroke is recommended though there is no consensus on optimal methods. Short-term ECG recordings with a "thumb-ECG" device have shown promising preliminary results regarding effectiveness and cost benefit. We aimed to examine the performance of thumb...... methods was poor and the trial was not powered to detect a minor difference between the devices. The inter-observer agreement for the thumb-ECG was substantial. www.clinicalTrials.gov UI: NCT02261766....

  6. Accuracy of ECG indices for diagnosis of left ventricular hypertrophy in people >65 years: results from the ActiFE study.

    Science.gov (United States)

    Laszlo, Roman; Kunz, Katia; Dallmeier, Dhayana; Klenk, Jochen; Denkinger, Michael; Koenig, Wolfgang; Rothenbacher, Dietrich; Steinacker, Juergen Michael

    2017-10-01

    The detection of left ventricular hypertrophy (LVH) is still a common objective of electrocardiography (ECG) in clinical practice. The aim of our study was to evaluate the accuracy of LVH ECG indices in people older than 65 recruited from a population-based cohort (ActiFE-Ulm study). In 432 subjects (mean age 76.2 ± 5.5 years, 51% male), left ventricular mass was echocardiographically determined (Devereux formula) and indexed (LVMI) to body surface area. Several LVH ECG indices (Lewis voltage, Gubner-Ungerleider voltage, Sokolow-Lyon voltage/product, Cornell voltage/product) were calculated with the help of resting ECG data and compared with the echocardiographic assessment. Despite echocardiographic signs of LVH [LVMI > 115 (♂) or >95 g/m 2 (♀)] in 47.5% of all subjects, diagnostic performance of all ECG indices was generally low. Magnitude of all LVH-indices was mainly predicted by frontal QRS axis in multivariate linear regression analysis. In comparison with the literature data from younger subjects, average frontal QRS axis turned counterclockwise. Most probably, age-related counterclockwise turn of frontal QRS axis is mainly explanatory for the decreased magnitude of LVH ECG indices and consecutive worse diagnostic performance of these indices in the elderly. ECG indices for detection of LVH have insufficient predictive values in geriatric subjects and should therefore not be used clinically for this purpose. Nevertheless, due to its established relevancy in cardiac risk stratification in this age group, usage of some established ECG indices might keep its significance even in the age of modern cardiac imaging.

  7. Measurement of ECG abnormalities and cardiovascular risk classification: a cohort study of primary care patients in the Netherlands

    NARCIS (Netherlands)

    de Groot, A.; Bots, M.L.; Rutten, F.H.; den Ruijter, H.M.; Numans, M.E.; Vaartjes, I.

    2015-01-01

    Background: GPs need accurate tools for cardiovascular (CV) risk assessment. Abnormalities in resting electrocardiograms (ECGs) relate to increased CV risk. Aim: To determine whether measurement of ECG abnormalities on top of established risk estimation (SCORE) improves CV risk classification in a

  8. Predictable and reliable ECG monitoring over IEEE 802.11 WLANs within a hospital.

    Science.gov (United States)

    Park, Juyoung; Kang, Kyungtae

    2014-09-01

    Telecardiology provides mobility for patients who require constant electrocardiogram (ECG) monitoring. However, its safety is dependent on the predictability and robustness of data delivery, which must overcome errors in the wireless channel through which the ECG data are transmitted. We report here a framework that can be used to gauge the applicability of IEEE 802.11 wireless local area network (WLAN) technology to ECG monitoring systems in terms of delay constraints and transmission reliability. For this purpose, a medical-grade WLAN architecture achieved predictable delay through the combination of a medium access control mechanism based on the point coordination function provided by IEEE 802.11 and an error control scheme based on Reed-Solomon coding and block interleaving. The size of the jitter buffer needed was determined by this architecture to avoid service dropout caused by buffer underrun, through analysis of variations in transmission delay. Finally, we assessed this architecture in terms of service latency and reliability by modeling the transmission of uncompressed two-lead electrocardiogram data from the MIT-BIH Arrhythmia Database and highlight the applicability of this wireless technology to telecardiology.

  9. 201Th chloride scintiscanning in myocardial infarction - correlation with ECG findings - diagnostic potential

    International Nuclear Information System (INIS)

    Kostka, I.

    1980-01-01

    The author intended to find out in how far myocardial scintiscanning with 201 Th chloride is a necessary auxiliary investigation in diagnosing acute myocardial infarction and whether there are correlations between ECG, increase of enzyme levels, and pressure measured in the lesser circulatory system. The scintiscans were evaluated by a new method: Defect sizes were determined using a transparent template and recorded in angular degrees. Also the reduced activity was considered. Especially posterior myocardial infarctions can be localized more easily and clearly by means of myocardial scintiscanning at rest, and also infarction sizes can be judged more easily. For a diagnosis of small myocardial infarctions or in patients with a block in their ECG picture, scintiscanning is a necessary part of the diagnostic spectrum. The findings of myocardial scintiscanning correspond well with those of other methods. As for the pressure increase in the lesser circulatory system, it is well correlated with the defect size shown by the scintiscan. 201 Th scintiscanning offers a good diagnostic possibility in those myocardial infarctions where ECG findings are ambiguous. (orig./MG) [de

  10. Super Memory Bros.: going from mirror patterns to concordant patterns via similarity enhancements.

    Science.gov (United States)

    Ozubko, Jason D; Joordens, Steve

    2008-12-01

    When memory is contrasted for stimuli belonging to distinct stimulus classes, one of two patterns is observed: a mirror pattern, in which one stimulus gives rise to higher hits but lower false alarms (e.g., the frequency-based mirror effect) or a concordant pattern, in which one stimulus class gives rise both to higher hits and to higher false alarms (e.g., the pseudoword effect). On the basis of the dual-process account proposed by Joordens and Hockley (2000), we predict that mirror patterns occur when one stimulus class is more familiar and less distinctive than another, whereas concordant patterns occur when one stimulus class is more familiar than another. We tested these assumptions within a video game paradigm using novel stimuli that allow manipulations in terms of distinctiveness and familiarity (via similarity). When more distinctive, less familiar items are contrasted with less distinctive, more familiar items, a mirror pattern is observed. Systematically enhancing the familiarity of stimuli transforms the mirror pattern to a concordant pattern as predicted. Although our stimuli differ considerably from those used in examinations of the frequency-based mirror effect and the pseudoword effect, the implications of our findings with respect to those phenomena are also discussed.

  11. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    Science.gov (United States)

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Cost-effectiveness of myocardial perfusion SPECT for diagnosis of coronary artery disease in Korea: comparison with exercise ECG and coronary angiography

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Kang, Keon Wook; Cheon, Gi Jeong; Jang, Myung Jin; Lee, Myoung Mook; Chung, June Key; Lee, Myung Chul

    2000-01-01

    Cost-effectiveness of myocardial SPECT for the diagnosis of coronary artery disease was investigated considering the present and amended costs of myocardial SPECT and exercise ECG in Korea. Four diagnostic tactics such as 1) coronary angiography (CAG) after exercise ECG, 2) CAG after myocardial SPECT, 3) direct CAG, and 4) CAG after myocardial SPECT following exercise ECG were chosen. Costs were calculated using the present costs of various tests and effects represented by Quality Adjusted Life Year (QALY) were estimated. Difference of QALY (ΔQALY) was calculated by subtracting QALY of diagnosed/treated cases from QALY of undiagnosed cases. Cost/ΔQALY was calculated and compared between four different tactics according to pre-test probability. When pre-test probability was equal to or larger than 0.6, direct CAG was the most cost-effective. When pre-test probability was between 0.2 and 0.6, CAG after myocardial SPECT following exercise ECG was the most cost-effective. CAG after myocardial SPECT was the second most cost-effective. Cost-effectiveness was similar when the costs of exercise ECG were doubled or quadrupled. CAG after exercise ECG was always the least cost-effective. Myocardial SPECT with or without preceding exercise ECG was the most cost-effective method to diagnose coronary artery disease in the present or expected amended cost system

  13. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    International Nuclear Information System (INIS)

    Luecke, Christian; Andres, Claudia; Foldyna, Borek; Nagel, Hans Dieter; Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas

    2012-01-01

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p 8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols

  14. Automatic recognition of cardiac arrhythmias based on the geometric patterns of Poincaré plots

    International Nuclear Information System (INIS)

    Zhang, Lijuan; Guo, Tianci; Xi, Bin; Fan, Yang; Wang, Kun; Bi, Jiacheng; Wang, Ying

    2015-01-01

    The Poincaré plot emerges as an effective tool for assessing cardiovascular autonomic regulation. It displays nonlinear characteristics of heart rate variability (HRV) from electrocardiographic (ECG) recordings and gives a global view of the long range of ECG signals. In the telemedicine or computer-aided diagnosis system, it would offer significant auxiliary information for diagnosis if the patterns of the Poincaré plots can be automatically classified. Therefore, we developed an automatic classification system to distinguish five geometric patterns of the Poincaré plots from four types of cardiac arrhythmias. The statistics features are designed on measurements and an ensemble classifier of three types of neural networks is proposed. Aiming at the difficulty to set a proper threshold for classifying the multiple categories, the threshold selection strategy is analyzed. 24 h ECG monitoring recordings from 674 patients, which have four types of cardiac arrhythmias, are adopted for recognition. For comparison, Support Vector Machine (SVM) classifiers with linear and Gaussian kernels are also applied. The experiment results demonstrate the effectiveness of the extracted features and the better performance of the designed classifier. Our study can be applied to diagnose the corresponding sinus rhythm and arrhythmia substrates disease automatically in the telemedicine and computer-aided diagnosis system. (paper)

  15. An Autonomous Wireless Sensor Node With Asynchronous ECG Monitoring in 0.18 μ m CMOS.

    Science.gov (United States)

    Mansano, Andre L; Li, Yongjia; Bagga, Sumit; Serdijn, Wouter A

    2016-06-01

    The design of a 13.56 MHz/402 MHz autonomous wireless sensor node with asynchronous ECG monitoring for near field communication is presented. The sensor node consists of an RF energy harvester (RFEH), a power management unit, an ECG readout, a data encoder and an RF backscattering transmitter. The energy harvester supplies the system with 1.25 V and offers a power conversion efficiency of 19% from a -13 dBm RF source at 13.56 MHz. The power management unit regulates the output voltage of the RFEH to supply the ECG readout with VECG = 0.95 V and the data encoder with VDE = 0.65 V . The ECG readout comprises an analog front-end (low noise amplifier and programmable voltage to current converter) and an asynchronous level crossing ADC with 8 bits resolution. The ADC output is encoded by a pulse generator that drives a backscattering transmitter at 402 MHz. The total power consumption of the sensor node circuitry is 9.7 μ W for a data rate of 90 kb/s and a heart rate of 70 bpm. The chip has been designed in a 0.18 μm CMOS process and shows superior RF input power sensitivity and lower power consumption when compared to previous works.

  16. Isolated T Wave Inversion in Lead aVL: An ECG Survey and a Case Report

    Directory of Open Access Journals (Sweden)

    Getaw Worku Hassen

    2015-01-01

    Full Text Available Background. Computerized electrocardiogram (ECG analysis has been of tremendous help for noncardiologists, but can we rely on it? The importance of ST depression and T wave inversions in lead aVL has not been emphasized and not well recognized across all specialties. Objective. This study’s goal was to analyze if there is a discrepancy of interpretation by physicians from different specialties and a computer-generated ECG reading in regard to a TWI in lead aVL. Methods. In this multidisciplinary prospective study, a single ECG with isolated TWI in lead aVL that was interpreted by the computer as normal was given to all participants to interpret in writing. The readings by all physicians were compared by level of education and by specialty to one another and to the computer interpretation. Results. A total of 191 physicians participated in the study. Of the 191 physicians 48 (25.1% identified and 143 (74.9% did not identify the isolated TWI in lead aVL. Conclusion. Our study demonstrated that 74.9% did not recognize the abnormality. New and subtle ECG findings should be emphasized in their training so as not to miss significant findings that could cause morbidity and mortality.

  17. Food and Insulin Effect on QT/QTC Interval of ECG

    Science.gov (United States)

    2014-08-19

    Effects of Different Meals on the QT/QTc Interval; Insulin and Oral Hypoglycemic [Antidiabetic] Drugs Causing Adverse Effects in Therapeutic Use; C-Peptide Effects on the QT/QTc Interval; Moxifloxacin ECG Profile in Fed and Fasted State; Japanese vs. Caucasian TQT Comparison

  18. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  19. Influence of the trigger technique on ventricular function measurements using 3-Tesla magnetic resonance imaging: comparison of ECG versus pulse wave triggering

    International Nuclear Information System (INIS)

    Sievers, Burkhard; Wiesner, Marco; Kiria, Nino; Speiser, Uwe; Schoen, Steffen; Strasser, Ruth H.

    2011-01-01

    Background Three Tesla cardiovascular magnetic resonance imaging (3T-CMR) is increasingly used in clinical practice. Despite many advantages one drawback is that ECG signal disturbances and artifacts increase with higher magnetic field strength resulting in trigger problems and false gating. This particularly affects cardiac imaging because most pulse sequences require ECG triggering. Pulse wave (PW) triggering is robust and might have advantages over ECG triggering. Purpose To evaluate differences in left ventricular (LV) function as an integral part of most CMR studies between ECG- and PW-triggered short-axis imaging using 3T-CMR. Material and Methods Forty-three patients underwent multiple short-axis cine imaging for LV-function assessment with ECG and PW triggering using standard multi breath hold steady-state free precession. LV-volumes (EDV, ESV), ejection fraction (EF), and mass were determined by slice summation. LV-wall motion was assessed by using a 4-point scoring scale. Bland Altman statistics for inter-observer variability were performed. Results ECG triggering failed in 15 patients (34.8%). Thus, analysis was performed in 28 patients (13 with impaired LV function). Difference in volumes (EDV 0.13 ± 1.8 mL, ESV 0.59 ± 1.1 mL), EF (-0.32 ± 0.6%) and mass (0.01 ± 1.1 g) between ECG and PW triggering were very small and significant only for ESV and EF (p 0.011). In patients with impaired LV function (n = 19) differences were not significant (p = 0.128). Wall motion scores did not differ between ECG and PW triggering (p = 0.295). Inter-observer variability for function measurements was low. Conclusion Short-axis cine imaging for LV-function assessment can accurately be performed using PW triggering on 3T magnets, and may be used in clinical practice when ECG triggering is disturbed

  20. Mapping Phylogenetic Trees to Reveal Distinct Patterns of Evolution.

    Science.gov (United States)

    Kendall, Michelle; Colijn, Caroline

    2016-10-01

    Evolutionary relationships are frequently described by phylogenetic trees, but a central barrier in many fields is the difficulty of interpreting data containing conflicting phylogenetic signals. We present a metric-based method for comparing trees which extracts distinct alternative evolutionary relationships embedded in data. We demonstrate detection and resolution of phylogenetic uncertainty in a recent study of anole lizards, leading to alternate hypotheses about their evolutionary relationships. We use our approach to compare trees derived from different genes of Ebolavirus and find that the VP30 gene has a distinct phylogenetic signature composed of three alternatives that differ in the deep branching structure. phylogenetics, evolution, tree metrics, genetics, sequencing. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  1. ECG Changes in Young Healthy Smokers: A Simple and Cost-Effective Method to Assess Cardiovascular Risk According to Pack-Years of Smoking.

    Science.gov (United States)

    Sharma, Nirmal Kumar; Jaiswal, Kapil Kumar; Meena, S R; Chandel, Rahul; Chittora, Saurabh; Goga, Prem Singh; Harish, H B; Sagar, Rajesh

    2017-06-01

    To document the prevalence of ECG abnormalities in young healthy smokers and compare ECG changes in smokers, young healthy non-smokers and amongst smokers with different pack years. This was a prospective case-control study consisting of 200 young healthy male and female individuals, 150 smokers and 50 non-smokers between ages 25-40 years, further categorized and compared according to age, sex and pack years of smoking. The ECG recordings were analyzed for different ECG parameters like heart rate, P-wave duration, P-wave amplitude, PR interval, QRS duration, RR-interval, ST-segment duration, QT interval and QTc interval. The results were compared using statistical tools. In present study abnormalities in ECG parameters were significantly more prevalent in smokers as compared to non-smokers (56.66 % Vs 6.00 %) (p non-invasive and cost effective it is potentially an effective and yet a simple method for cardiovascular risk evaluation in smokers. Furthermore, such ECG abnormalities may guide the clinician for risk evaluation in smokers and may be used to convince the smokers to quit smoking.

  2. Efficient Skin Temperature Sensor and Stable Gel-Less Sticky ECG Sensor for a Wearable Flexible Healthcare Patch.

    Science.gov (United States)

    Yamamoto, Yuki; Yamamoto, Daisuke; Takada, Makoto; Naito, Hiroyoshi; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu

    2017-09-01

    Wearable, flexible healthcare devices, which can monitor health data to predict and diagnose disease in advance, benefit society. Toward this future, various flexible and stretchable sensors as well as other components are demonstrated by arranging materials, structures, and processes. Although there are many sensor demonstrations, the fundamental characteristics such as the dependence of a temperature sensor on film thickness and the impact of adhesive for an electrocardiogram (ECG) sensor are yet to be explored in detail. In this study, the effect of film thickness for skin temperature measurements, adhesive force, and reliability of gel-less ECG sensors as well as an integrated real-time demonstration is reported. Depending on the ambient conditions, film thickness strongly affects the precision of skin temperature measurements, resulting in a thin flexible film suitable for a temperature sensor in wearable device applications. Furthermore, by arranging the material composition, stable gel-less sticky ECG electrodes are realized. Finally, real-time simultaneous skin temperature and ECG signal recordings are demonstrated by attaching an optimized device onto a volunteer's chest. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.

    Science.gov (United States)

    Gao, Wei; Zhong, Yu Min; Sun, Ai Min; Wang, Qian; Ouyang, Rong Zhen; Hu, Li Wei; Qiu, Han Sheng; Wang, Shi Yu; Li, Jian Ying

    2016-06-01

    To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.

  4. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks.

    Science.gov (United States)

    Peter, Steffen; Reddy, Bhanu Pratap; Momtaz, Farshad; Givargis, Tony

    2016-04-22

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system.

  5. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks

    Science.gov (United States)

    Peter, Steffen; Pratap Reddy, Bhanu; Momtaz, Farshad; Givargis, Tony

    2016-01-01

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system. PMID:27110785

  6. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks

    Directory of Open Access Journals (Sweden)

    Steffen Peter

    2016-04-01

    Full Text Available Body area sensor networks (BANs utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system.

  7. [Stress-ECG is adequate to detect myocardial ischemia: when are additional diagnostic tests needed?].

    Science.gov (United States)

    Baer, F M

    2007-09-01

    The stress-ECG is the most often adopted and most cost effective initial diagnostic test for the assessment of myocardial ischemia in patients with suspected coronary artery disease (CAD). Prerequisites for the diagnostic usefullness of stress-ECG are a clearly interpretable ST-segment, ability to reach the predicted work load, an intermediate pretest probability for CAD ranging between 10% and 90% and the absence of any contraindications for dynamic exercise. Because of the limited diagnostic sensitivity of about 70%, and a high percentage of patients, who are unable to exercise, a negative stress ECG can definitely not exclude hemodynamically significant CAD. Therefore, stress imaging techniques like myocardial scintigraphy, stress-echocardiography and stress magnetic resonance imaging play a major role in the stepwise diagnostic work-up of patients with suspected CAD. These stress imaging techniques are basically interchangeable since no method is definitely superior to one of the others. However, each method has its specific pros and cons and inherent contraindications. Therefore the choice of the stress imaging method and the form of stress applied should be based on the individual patients characteristics to gain optimal image quality and diagnostic accuracy. Moreover, the decision for one method should take the local availability and institutional expertise of diagnostic centers into account. Although partly substituted by stress imaging techniques the stress-ECG still remains the workhorse for a stepwise diagnostic work-up of patients with suspected CAD.

  8. An intelligent telecardiology system using a wearable and wireless ECG to detect atrial fibrillation.

    Science.gov (United States)

    Lin, Chin-Teng; Chang, Kuan-Cheng; Lin, Chun-Ling; Chiang, Chia-Cheng; Lu, Shao-Wei; Chang, Shih-Sheng; Lin, Bor-Shyh; Liang, Hsin-Yueh; Chen, Ray-Jade; Lee, Yuan-Teh; Ko, Li-Wei

    2010-05-01

    This study presents a novel wireless, ambulatory, real-time, and autoalarm intelligent telecardiology system to improve healthcare for cardiovascular disease, which is one of the most prevalent and costly health problems in the world. This system consists of a lightweight and power-saving wireless ECG device equipped with a built-in automatic warning expert system. This device is connected to a mobile and ubiquitous real-time display platform. The acquired ECG signals are instantaneously transmitted to mobile devices, such as netbooks or mobile phones through Bluetooth, and then, processed by the expert system. An alert signal is sent to the remote database server, which can be accessed by an Internet browser, once an abnormal ECG is detected. The current version of the expert system can identify five types of abnormal cardiac rhythms in real-time, including sinus tachycardia, sinus bradycardia, wide QRS complex, atrial fibrillation (AF), and cardiac asystole, which is very important for both the subjects who are being monitored and the healthcare personnel tracking cardiac-rhythm disorders. The proposed system also activates an emergency medical alarm system when problems occur. Clinical testing reveals that the proposed system is approximately 94% accurate, with high sensitivity, specificity, and positive prediction rates for ten normal subjects and 20 AF patients. We believe that in the future a business-card-like ECG device, accompanied with a mobile phone, can make universal cardiac protection service possible.

  9. An Adaptive Particle Weighting Strategy for ECG Denoising Using Marginalized Particle Extended Kalman Filter: An Evaluation in Arrhythmia Contexts.

    Science.gov (United States)

    Hesar, Hamed Danandeh; Mohebbi, Maryam

    2017-11-01

    Model-based Bayesian frameworks have a common problem in processing electrocardiogram (ECG) signals with sudden morphological changes. This situation often happens in the case of arrhythmias where ECGs do not obey the predefined state models. To solve this problem, in this paper, a model-based Bayesian denoising framework is proposed using marginalized particle-extended Kalman filter (MP-EKF), variational mode decomposition, and a novel fuzzy-based adaptive particle weighting strategy. This strategy helps MP-EKF to perform well even when the morphology of signal does not comply with the predefined dynamic model. In addition, this strategy adapts MP-EKF's behavior to the acquired measurements in different input signal to noise ratios (SNRs). At low input SNRs, this strategy decreases the particles' trust level to the measurements while increasing their trust level to a synthetic ECG constructed with the feature parameters of ECG dynamic model. At high input SNRs, the particles' trust level to the measurements is increased and the trust level to synthetic ECG is decreased. The proposed method was evaluated on MIT-BIH normal sinus rhythm database and compared with EKF/EKS frameworks and previously proposed MP-EKF. It was also evaluated on ECG segments extracted from MIT-BIH arrhythmia database, which contained ventricular and atrial arrhythmia. The results showed that the proposed algorithm had a noticeable superiority over benchmark methods from both SNR improvement and multiscale entropy based weighted distortion (MSEWPRD) viewpoints at low input SNRs.

  10. A robust physiology-based source separation method for QRS detection in low amplitude fetal ECG recordings

    International Nuclear Information System (INIS)

    Vullings, R; Bergmans, J W M; Peters, C H L; Hermans, M J M; Wijn, P F F; Oei, S G

    2010-01-01

    The use of the non-invasively obtained fetal electrocardiogram (ECG) in fetal monitoring is complicated by the low signal-to-noise ratio (SNR) of ECG signals. Even after removal of the predominant interference (i.e. the maternal ECG), the SNR is generally too low for medical diagnostics, and hence additional signal processing is still required. To this end, several methods for exploiting the spatial correlation of multi-channel fetal ECG recordings from the maternal abdomen have been proposed in the literature, of which principal component analysis (PCA) and independent component analysis (ICA) are the most prominent. Both PCA and ICA, however, suffer from the drawback that they are blind source separation (BSS) techniques and as such suboptimum in that they do not consider a priori knowledge on the abdominal electrode configuration and fetal heart activity. In this paper we propose a source separation technique that is based on the physiology of the fetal heart and on the knowledge of the electrode configuration. This technique operates by calculating the spatial fetal vectorcardiogram (VCG) and approximating the VCG for several overlayed heartbeats by an ellipse. By subsequently projecting the VCG onto the long axis of this ellipse, a source signal of the fetal ECG can be obtained. To evaluate the developed technique, its performance is compared to that of both PCA and ICA and to that of augmented versions of these techniques (aPCA and aICA; PCA and ICA applied on preprocessed signals) in generating a fetal ECG source signal with enhanced SNR that can be used to detect fetal QRS complexes. The evaluation shows that the developed source separation technique performs slightly better than aPCA and aICA and outperforms PCA and ICA and has the main advantage that, with respect to aPCA/PCA and aICA/ICA, it performs more robustly. This advantage renders it favorable for employment in automated, real-time fetal monitoring applications

  11. Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

    Science.gov (United States)

    Dolezal, B. A.; Storer, T. W.; Abrazado, M.; Watne, R.; Schlegel, T. T.; Batalin, M.; Kaiser, W.; Smith, D. L.; Cooper, C. B.

    2011-01-01

    INTRODUCTION Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. Screening for cardiovascular risk factors is recommended but not always followed in this population. PHASER is a project charged with identifying and prioritizing risk factors in emergency responders. We have deployed an advanced ECG (A-ECG) system developed at NASA for improved sensitivity and specificity in the detection of cardiac risk. METHODS Forty-four professional firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance and laboratory tests for fasting lipid profiles and glucose. Heart rate and conventional 12-lead ECG were obtained at rest and during incremental treadmill exercise testing (XT). In addition, a 5-min resting 12-lead A-ECG was obtained in a subset of firefighters (n=18) and transmitted over a secure networked system to a physician collaborator at NASA for advanced-ECG analysis. This A-ECG system has been proven, using myocardial perfusion and other imaging, to accurately identify a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, non-ischemic cardiomyopathy, and ischemic cardiomyopathy. RESULTS Subjects mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI of 28 (3) kg/square meter. Maximum oxygen uptake (VO2max) was 39 (9) ml/kg/min. This compares with the 45th %ile in healthy reference values and a recommended standard of 42 ml/kg/min for firefighters. The metabolic threshold (VO

  12. Impact of diagnostic ECG to wire delay in STEMI patients treated with primary PCI - a DANAMI-3 substudy

    DEFF Research Database (Denmark)

    Nepper-Christensen, Lars; Lønborg, Jacob; Høfsten, Dan Eik

    2018-01-01

    AIMS: We evaluated the impact of delay from diagnostic pre-hospital electrocardiogram (ECG) to wiring of the infarct related vessel (ECG-to-wire) >120 minutes on cardiovascular magnetic resonance (CMR) markers of reperfusion success and clinical outcome in patients with ST-segment elevation...... myocardial infarction (STEMI). METHODS AND RESULTS: We included 1492 patients in the analyses of clinical outcome. CMR was performed in 748 patients to evaluate infarct size and myocardial salvage. In total, 304 patients (20%) had ECG-to-wire >120 minutes, which was associated with larger acute infarct size...... (18% [interquartile range (IQR), 10-28] vs. 15% [8-24]; p=0.022) and smaller myocardial salvage (0.42 [IQR 0.28-0.57] vs. 0.50 [IQR 0.34-0.70]; p=0.002). However, 33% of the patients with ECG-to-wire >120 minutes still had a substantial myocardial salvage of more than 0.50. In a multivariable analysis...

  13. Instant noodle intake and dietary patterns are associated with distinct cardiometabolic risk factors in Korea.

    Science.gov (United States)

    Shin, Hyun Joon; Cho, Eunyoung; Lee, Hae-Jeung; Fung, Teresa T; Rimm, Eric; Rosner, Bernard; Manson, JoAnn E; Wheelan, Kevin; Hu, Frank B

    2014-08-01

    The consumption of instant noodles is relatively high in Asian populations. It is unclear whether a higher intake of instant noodles is associated with cardiometabolic risk independent of overall dietary patterns. We therefore investigated the association using the Korean National Health and Nutrition Examination Survey IV 2007-2009, a nationally representative cross-sectional survey of the Korean population with a clustered, multistage, stratified, and rolling sampling design. A total of 10,711 adults (54.5% women) 19-64 y of age were analyzed, with adjustment for sampling design complexity. Diet was assessed by using a 63-item food-frequency questionnaire. We identified 2 major dietary patterns with the use of principal components analysis: the "traditional dietary pattern" (TP), rich in rice, fish, vegetables, fruit, and potatoes, and the "meat and fast-food pattern" (MP), with less rice intake but rich in meat, soda, fried food, and fast food including instant noodles. The highest MP quintile was associated with increased prevalence of abdominal obesity (OR: 1.41; 95% CI: 1.05, 1.90), LDL cholesterol ≥130 mg/dL (1.3 g/L) (OR: 1.57, 95% CI 1.26, 1.95), decreased prevalence of low HDL cholesterol (OR: 0.65; 95% CI: 0.53, 0.80), and high triglycerides [≥150 mg/dL (1.5 g/L); OR: 0.73; 95% CI: 0.57, 0.93]. The highest quintile for the TP was associated with decreased prevalence of elevated blood pressure (OR: 0.73; 95% CI: 0.59, 0.90) and marginally lower trends for abdominal obesity (OR: 0.76; 95% CI: 0.58, 0.98; P-trend = 0.06), but neither of the dietary patterns was associated with prevalence of metabolic syndrome. The consumption of instant noodles ≥2 times/wk was associated with a higher prevalence of metabolic syndrome (OR: 1.68; 95% CI: 1.10, 2.55) in women but not in men (OR: 0.93; 95% CI: 0.58, 1.49; P-interaction = 0.04). The 2 major dietary patterns were associated with distinct cardiometabolic risk factors. The consumption of instant noodles was

  14. A novel method for the detection of R-peaks in ECG based on K-Nearest Neighbors and Particle Swarm Optimization

    Science.gov (United States)

    He, Runnan; Wang, Kuanquan; Li, Qince; Yuan, Yongfeng; Zhao, Na; Liu, Yang; Zhang, Henggui

    2017-12-01

    Cardiovascular diseases are associated with high morbidity and mortality. However, it is still a challenge to diagnose them accurately and efficiently. Electrocardiogram (ECG), a bioelectrical signal of the heart, provides crucial information about the dynamical functions of the heart, playing an important role in cardiac diagnosis. As the QRS complex in ECG is associated with ventricular depolarization, therefore, accurate QRS detection is vital for interpreting ECG features. In this paper, we proposed a real-time, accurate, and effective algorithm for QRS detection. In the algorithm, a proposed preprocessor with a band-pass filter was first applied to remove baseline wander and power-line interference from the signal. After denoising, a method combining K-Nearest Neighbor (KNN) and Particle Swarm Optimization (PSO) was used for accurate QRS detection in ECGs with different morphologies. The proposed algorithm was tested and validated using 48 ECG records from MIT-BIH arrhythmia database (MITDB), achieved a high averaged detection accuracy, sensitivity and positive predictivity of 99.43, 99.69, and 99.72%, respectively, indicating a notable improvement to extant algorithms as reported in literatures.

  15. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, Christian, E-mail: neep@gmx.de [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Andres, Claudia; Foldyna, Borek [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Nagel, Hans Dieter [Wissenschaft and Technik für die Radiologie, Buchhholz i.d.N (Germany); Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany)

    2012-09-15

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p < 0.05) were bifocal pacemaker (61%), pacemaker dysfunction (22%), SVES (20%), ventricular salvo (20%), and atrial fibrillation (14%). Significantly (p < 0.05) prolonged scan time (>8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols.

  16. Use of electrocardiogram (ECG) electrodes for Bioelectrical Impedance Analysis (BIA)

    International Nuclear Information System (INIS)

    Caicedo-Eraso, J C; González-Correa, C H; González-Correa, C A

    2012-01-01

    BIA is a safe, noninvasive, portable and relatively inexpensive method of estimating body composition that is practical and suitable for individual use and large-scale studies. However, the cost of the electrodes recommended by some BIA manufacturers is too high for developing countries; where very often the long and complicated process of importation reduces the time they can be used. The purpose of this study was to evaluate the use of two types of ECG electrodes (2290 and 2228 by 3M ® ) in BIA measurements to decrease the costs of the test. The results showed that the 2228 ECG electrodes can be used in BIA measurements for adult's body composition assessment. These electrodes are available in the domestic market and their costs are 92% lower than the electrodes recommended by manufacturer. The results show a new cost-benefit relation for BIA method and make this a more accessible tool for individual tests, large-scale researches and studies in the community.

  17. Autophagic effects of Hibiscus sabdariffa leaf polyphenols and epicatechin gallate (ECG) against oxidized LDL-induced injury of human endothelial cells.

    Science.gov (United States)

    Chen, Jing-Hsien; Lee, Ming-Shih; Wang, Chi-Ping; Hsu, Cheng-Chin; Lin, Hui-Hsuan

    2017-08-01

    Oxidized low-density lipoprotein (ox-LDL) contributes to the pathogenesis of atherosclerosis by promoting vascular endothelial cell injury. Hibiscus sabdariffa leaf polyphenols (HLP), rich in flavonoids, have been shown to possess antioxidant and antiatherosclerotic activities. In this study, we examined the protective role of HLP and its main compound (-)-epicatechin gallate (ECG) in human umbilical vein endothelial cells (HUVECs) exposed to ox-LDL in vitro. In a model of ox-LDL-impaired HUVECs, assessments of cell viability, cytotoxicity, cell proliferation, apoptosis, and autophagy were detected. To highlight the mechanisms of the antiapoptotic effects of HLP and ECG, the expressions of molecular proteins were measured by Western blotting, real-time PCR, and so on. HLP or ECG improved the survival of HUVECs from ox-LDL-induced viability loss. In addition, HLP or ECG showed potential in reducing ox-LDL-dependent apoptosis. Next, the ox-LDL-induced formation of acidic vesicular organelles and upregulation of the autophagy-related genes were increased by HLP or ECG. The HLP-triggered autophagic flux was further confirmed by increasing the LC3-II level under the pretreatment of an autophagy inhibitor chloroquine. Molecular data indicated the autophagic effect of HLP or ECG might be mediated via class III PI3K/Beclin-1 and PTEN/class I PI3K/Akt cascade signaling, as demonstrated by the usage of a class III PI3K inhibitor 3-methyladenine (3-MA) and a PTEN inhibitor SF1670. Our data imply that ECG-enriched HLP upregulates the autophagic pathway, which in turn led to reduce ox-LDL-induced HUVECs injury and apoptosis and provide a new mechanism for its antiatherosclerotic activity.

  18. The effect of administering equine chorionic gonadotropin (eCG) and human chorionic gonadotropin (hCG) post artificial insemination on fertility of lactating dairy cows.

    Science.gov (United States)

    Bartolome, J A; Wallace, S Perez; de la Sota, R L; Thatcher, W W

    2012-09-15

    The objective was to evaluate the effect of equine chorionic gonadotropin (eCG) and hCG post artificial insemination (AI) on fertility of lactating dairy cows. In Experiment 1, cows were either treated with eCG on Day 22 post AI (400 IU; n = 80) or left untreated (n = 84). On Day 29, pregnant cows were either treated with hCG (2500 IU; n = 32) or left untreated (n = 36). Pregnancy and progesterone were evaluated on Days 29 and 45. In Experiment 2, cows (n = 28) were either treated with eCG on Day 22 (n = 13) or left untreated (n = 15) and either treated with hCG on Day 29 (n = 14) or left untreated (n = 14). Blood sampling and ultrasonography were conducted between Days 22 and 45. In Experiment 3, cows were either treated with eCG on Day 22 post AI (n = 229) or left untreated (n = 241). Pregnancy was evaluated on Days 36 and 85. In Experiment 1, eCG on Day 22 increased (P cows on Day 29 (50.0 vs. 33.3%) and on Day 45, the increase was higher (P cows with timed AI (41.2 vs. 6.5%) than in cows AI at detected estrus (50.0 vs. 37.8%). Pregnancy losses were reduced by eCG and hCG, but increased in cows that did not receive eCG but were given hCG (P cows, but not in cows treated with eCG. In Experiment 2, hCG increased (P cows (P cows with low body condition (eCG = 45.6 and 43.5%; Control = 22.9 and 22.9%). In conclusion, eCG at 22 days post insemination increased fertility, primarily in cows with low body condition and reduced pregnancy losses when given 7 days before hCG; hCG induced accessory CLs and slightly increased progesterone, but hCG given in the absence of a prior eCG treatment reduced fertility. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    Science.gov (United States)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  20. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    International Nuclear Information System (INIS)

    O’Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-01-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact.This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface. (paper)