WorldWideScience

Sample records for distal biceps tendon

  1. Ultrasound demonstration of distal biceps tendon bifurcation: normal and abnormal findings

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Capaccio, Enrico; Derchi, Lorenzo E.; Martinoli, Carlo; Michaud, Johan

    2010-01-01

    We demonstrate the US appearance of the distal biceps tendon bifurcation in normal cadavers and volunteers and in those affected by various disease processes. Three cadaveric specimens, 30 normal volunteers, and 75 patients were evaluated by means of US. Correlative MR imaging was obtained in normal volunteers and patients. In all cases US demonstrated the distal biceps tendon shaped by two separate tendons belonging to the short and long head of the biceps brachii muscle. Four patients had a complete rupture of the distal insertion of the biceps with retraction of the muscle belly. Four patients had partial tear of the distal biceps tendon with different US appearance. In two patients the partial tear involved the short head of the biceps brachii tendon, while in the other two patients, the long head was involved. Correlative MR imaging is also presented both in normal volunteers and patients. US changed the therapeutic management in the patients with partial tears involving the LH of the biceps. This is the first report in which ultrasound considers the distal biceps tendon bifurcation in detail. Isolated tears of one of these components can be identified by US. Knowledge of the distal biceps tendon bifurcation ultrasonographic anatomy and pathology has important diagnostic and therapeutic implications. (orig.)

  2. Surgical treatment of distal biceps tendon rupture: a case report

    Directory of Open Access Journals (Sweden)

    Cristina N. Cozma

    2017-11-01

    Full Text Available Objectives. Distal biceps tendon rupture affects the functional upperextremity movement, impairing supination and flexion strength. According to age, profession and additional risks treatment might be nonoperative or surgical. Methods. We describe the case of a 43 years old male patient who sustained an injury to his right distal biceps and was diagnosed with acute right distal biceps rupture. Surgical treatment was decided and biceps tendon was reinserted to the radius tuberosity using a combination of a cortical button fixation associated with an interference screw. Results. Postoperative functional result was favorable with no complications and with no movement limitation after one month. Conclusions. When possible, distal biceps tendon repair should be realized surgically because this permits restoring of the muscle strength to near normal levels with no loss of motion. Nerve complications are common; therefore the surgery should be realized by experienced upper extremity surgeons.

  3. Complete rupture of the long head of the biceps tendon and the distal biceps tendon

    Directory of Open Access Journals (Sweden)

    Pieter J. Oberholzer

    2014-12-01

    Full Text Available The most common injury to the biceps muscle is rupture of the long head of the biceps tendon. A tear can occur proximally, distally or at the musculotendinous junction. Two cases are discussed, in both of which the patients felt a sudden sharp pain in the upper arm, at the shoulder and elbow respectively, and presented with a biceps muscle bump (Popeye deformity.

  4. Simultaneous bilateral distal biceps tendon repair: case report

    Directory of Open Access Journals (Sweden)

    Thiago Medeiros Storti

    Full Text Available ABSTRACT Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  5. Simultaneous bilateral distal biceps tendon repair: case report.

    Science.gov (United States)

    Storti, Thiago Medeiros; Paniago, Alexandre Firmino; Faria, Rafael Salomon Silva

    2017-01-01

    Simultaneous bilateral rupture of the distal biceps tendon is a rare clinical entity, seldom reported in the literature and with unclear therapeutic setting. The authors report the case of a 39-year-old white man who suffered a simultaneous bilateral rupture while working out. When weightlifting with elbows at 90° of flexion, he suddenly felt pain on the anterior aspect of the arms, coming for evaluation after two days. He presented bulging contour of the biceps muscle belly and ecchymosis in the antecubital fossa, extending distally to the medial aspect of the forearm, as well as a marked decrease of supination strength and pain in active elbow flexion. MRI confirmed the rupture with retraction of the distal biceps bilaterally. The authors opted for performing the tendon repairs simultaneously through the double incision technique and fixation to the bicipital tuberosity with anchors. The patient progressed quite well, with full return to labor and sports activities, being satisfied with the result after two years of surgery. In the literature search, few reports of simultaneous bilateral rupture of the distal biceps were retrieved, with only one treated in the acute phase of injury. Therefore, the authors consider this procedure to be a good option to solve this complex condition.

  6. Partial tears of the distal biceps tendon: MR appearance and associated clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Williams, B.D.; Schweitzer, M.E.; Weishaupt, D.; Miller, L.S. [Thomas Jefferson Univ., Philadelphia, PA (United States). Dept. of Radiology; Lerman, J. [Lerman Imaging, Brooklyn, NY (United States); Rubenstein, D.L. [Orthopaedic Surgery, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Rosenberg, Z.S. [Dept. of Diagnostic Radiology, New York Univ. Medical Center, NY (United States)

    2001-10-01

    Purpose: To describe the magnetic resonance (MR) appearance and associated clinical findings of partial distal biceps tendon tears. Design: Twenty elbow MR images at 1.5 T, performed over a 7 year period, were reviewed for an appearance of partial tears in the distal biceps. These images were assessed by two musculoskeletal radiologists for the extent of: (a) abnormal signal intensity within the tendon, and the presence of (b) bicipitoradial bursitis, and (c) bony microavulsive injury of the radial tuberosity. Medical records for nine of the 20 cases were reviewed for the clinical findings of ecchymosis, trauma, sensation of a ''pop'', loss of function, and acuity of onset. Results: Twenty partial distal biceps tendon tears were seen. All displayed an abnormally increased signal in the distal biceps tendon. Three of 20 (15%) showed a 25% to 50% tear, ten of 20 (50%) showed a 50% tear, and seven of 20 (35%) showed a 75% to 90% tear. Bicipitoradial bursitis was seen in 11 of 20 (55%) cases. Bony microavulsive injury of the radial tuberosity was observed in 10 of 20 (50%). Of the nine cases reviewed for associated clinical findings, surprisingly, only three (33%) experienced an acute traumatic episode with an abrupt onset of pain. An insidious onset was reported in four of nine (44%). Sensation of a ''pop'' was recorded in only two of nine (22%) cases. Ecchymosis and loss of function were not seen in any of the cases. Finally, surgical conformation was obtained for three cases. Conclusion: Partial distal biceps tendon tears have a characteristic MR appearance, demonstrate little functional deficit, and may be attritional in their etiology due to the observation of a low number of patients reporting trauma or an acute onset. (orig.)

  7. Partial tears of the distal biceps tendon: MR appearance and associated clinical findings

    International Nuclear Information System (INIS)

    Williams, B.D.; Schweitzer, M.E.; Weishaupt, D.; Miller, L.S.; Rubenstein, D.L.; Rosenberg, Z.S.

    2001-01-01

    Purpose: To describe the magnetic resonance (MR) appearance and associated clinical findings of partial distal biceps tendon tears. Design: Twenty elbow MR images at 1.5 T, performed over a 7 year period, were reviewed for an appearance of partial tears in the distal biceps. These images were assessed by two musculoskeletal radiologists for the extent of: (a) abnormal signal intensity within the tendon, and the presence of (b) bicipitoradial bursitis, and (c) bony microavulsive injury of the radial tuberosity. Medical records for nine of the 20 cases were reviewed for the clinical findings of ecchymosis, trauma, sensation of a ''pop'', loss of function, and acuity of onset. Results: Twenty partial distal biceps tendon tears were seen. All displayed an abnormally increased signal in the distal biceps tendon. Three of 20 (15%) showed a 25% to 50% tear, ten of 20 (50%) showed a 50% tear, and seven of 20 (35%) showed a 75% to 90% tear. Bicipitoradial bursitis was seen in 11 of 20 (55%) cases. Bony microavulsive injury of the radial tuberosity was observed in 10 of 20 (50%). Of the nine cases reviewed for associated clinical findings, surprisingly, only three (33%) experienced an acute traumatic episode with an abrupt onset of pain. An insidious onset was reported in four of nine (44%). Sensation of a ''pop'' was recorded in only two of nine (22%) cases. Ecchymosis and loss of function were not seen in any of the cases. Finally, surgical conformation was obtained for three cases. Conclusion: Partial distal biceps tendon tears have a characteristic MR appearance, demonstrate little functional deficit, and may be attritional in their etiology due to the observation of a low number of patients reporting trauma or an acute onset. (orig.)

  8. Rupture of the Distal Biceps Tendon Combined with a Supinator Muscle Tear in a 51-Year-Old Woman: A Case Report

    Directory of Open Access Journals (Sweden)

    Samir Nayyar

    2011-01-01

    Full Text Available Distal biceps tendon rupture is a relatively uncommon occurrence in the general female population, and to our knowledge, has not been reported in association with a supinator muscle tear. We report a case of 51-year-old woman who experienced sharp pain in her forearm and elbow after lifting a heavy object. History and physical examination raised suspicion for a distal biceps tendon rupture. MRI imaging determined a combined distal biceps tendon tear with a supinator muscle tear with subsequent confirmation at surgery. Surgical repair was performed for the distal biceps tendon only through a single incision approach using the Endobutton technique.

  9. Rupture of the Distal Biceps Tendon Combined with a Supinator Muscle Tear in a 51-Year-Old Woman: A Case Report

    OpenAIRE

    Nayyar, Samir; Quirno, Martin; Hasan, Saqib; Rybak, Leon; Meislin, Robert J.

    2011-01-01

    Distal biceps tendon rupture is a relatively uncommon occurrence in the general female population, and to our knowledge, has not been reported in association with a supinator muscle tear. We report a case of 51-year-old woman who experienced sharp pain in her forearm and elbow after lifting a heavy object. History and physical examination raised suspicion for a distal biceps tendon rupture. MRI imaging determined a combined distal biceps tendon tear with a supinator muscle tear with subsequen...

  10. Simultaneous bilateral distal biceps tendon rupture during a preacher curl exercise: a case report.

    Science.gov (United States)

    Rokito, Andrew S; lofin, Ilya

    2008-01-01

    Complete rupture of the distal biceps tendon is a rare injury, the overwhelming majority occurring in the dominant arm of males during the fourth to sixth decades of life. Simultaneous bilateral rupture of the distal biceps tendon is an extremely rare occurrence, with only three cases reported in the literature. This unusual injury occurred in a recreational weightlifter during a preacher curl exercise. In this particular case, a 6-week delay in presentation necessitated a staged procedure in which a primary repair was feasible in one elbow, while reconstruction using allograft tissue was required in the contralateral elbow. Satisfactory results for both elbows were achieved, with return to weightlifting by one year following surgery.

  11. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    Science.gov (United States)

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon

  12. Repair of the torn distal biceps tendon by endobutton fixation

    Directory of Open Access Journals (Sweden)

    Ravi K Gupta

    2012-01-01

    Full Text Available Background: A number of techniques have been described to reattach the torn distal biceps tendon to the bicipital tuberosity. We report a retrospective analysis of single incision technique using an endobutton fixation in sports persons. Materials and Methods: The present series include nine torn distal biceps tendons in eight patients, fixed anatomically to the radial tuberosity with an endobutton by using a single incision surgical technique; seven patients had suffered the injuries during contact sports. The passage of the endobutton was facilitated by using a blunt tipped pin in order to avoid injury to the posterior interosseous nerve. The patients were evaluated by Disabilities of the Arm, Shoulder and Hand (DASH score and Mayo elbow score. Results: The average age of the patients was 27.35 years (range 21-42 years. Average follow-up was 41.5 months (range 24-102 months. The final average flexion extension arc was 0°-143°, while the average pronation and supination angles were 77° (range 70°-82° and 81° (range 78°-85°, respectively at the last followup. All the patients had a Disabilities of the Arm, Shoulder and Hand (DASH score of 0 and a Mayo elbow score of 100 each. All the seven active sports persons were able to get back to their respective game. There was no nerve injury or any other complication. Conclusions: The surgical procedure used by us is a simple, safe and reproducible technique giving minimal morbidity and better cosmetic results.

  13. Clinical relevance of distal biceps insertional and footprint anatomy

    NARCIS (Netherlands)

    van den Bekerom, Michel P J; Kodde, Izaäk F.; Aster, Asir; Bleys, Ronald L A W; Eygendaal, Denise

    2016-01-01

    Purpose: The aim of this review was to present an overview, based on a literature search, of surgical anatomy for distal biceps tendon repairs, based on the current literature. Methods: A narrative review was performed using Pubmed/Medline using key words: Search terms were distal biceps,

  14. REHABILITATION OF A SURGICALLY REPAIRED RUPTURE OF THE DISTAL BICEPS TENDON IN AN ACTIVE MIDDLE AGED MALE: A CASE REPORT

    Science.gov (United States)

    Sayers, Stephen P.; LaFontaine, Tom; Scheussler, Scott

    2012-01-01

    Background: Complete rupture of the distal tendon of the biceps brachii is relatively rare and there is little information to guide therapists in rehabilitation after this injury. The purposes of this case report are to review the rehabilitation concepts used for treating such an injury, and discuss how to modify exercises during rehabilitation based on patient progression while adhering to physician recommended guidelines and standard treatment protocols. Case Presentation: The patient was an active 38‐year old male experienced in weight‐training. He presented with a surgically repaired right distal biceps tendon following an accident on a trampoline adapted with a bungee suspension harness. The intervention focused on restoring range of motion and strengthening of the supporting muscles of the upper extremity without placing undue stress on the biceps brachii. Outcomes: The patient was able to progress from a moderate restriction in ROM to full AROM two weeks ahead of the physician's post‐operative orders and initiate a re‐strengthening protocol by the eighth week of rehabilitation. At the eighth post‐operative week the patient reported no deficits in functional abilities throughout his normal daily activities with his affected upper extremity. Discussion: The results of this case report strengthen current knowledge regarding physical therapy treatment for a distal biceps tendon repair while at the same time providing new insights for future protocol considerations in active individuals. Most current protocols do not advocate aggressive stretching, AROM, or strengthening of a surgically repaired biceps tendon early in the rehabilitation process due to the fear of a re‐rupture. In the opinion of the authors, if full AROM can be achieved before the 6th week of rehabilitation, initiating a slow transition into light strengthening of the biceps brachii may be possible. Level of evidence: 4‐Single Case report PMID:23316429

  15. Simultaneous acute rotator cuff tear and distal biceps rupture in a strongman competitor.

    Science.gov (United States)

    George, Michael S

    2010-04-01

    Acute rotator cuff tear is commonly associated with tearing of the proximal biceps tendon, but has never been reported to occur simultaneously with a distal biceps tendon rupture. A 38-year-old right-hand-dominant strongman competitor attempted a 300-pound overhead axle press and experienced immediate pain in the right shoulder and elbow. He had no known systemic risk factors for tendon ruptures including hyperparathyroidism, hemodialysis, alcoholism, rheumatoid arthritis, statin medications, fluoroquinolones, and steroid use.Right shoulder magnetic resonance imaging (MRI) showed a full-thickness supraspinatus tear with 3 cm of retraction. There was minimal fatty infiltration of the supraspinatus on the sagittal cuts consistent with acute rupture. The subscapularis was intact. The long head of the biceps tendon had mild medial subluxation but was completely within the bicipital groove. Right elbow MRI showed a complete distal biceps tendon rupture. Thirteen days after his injury, the patient underwent arthroscopic supraspinatus repair and proximal biceps tenodesis. Distal biceps tendon repair was performed using the modified 2-incision muscle-splitting technique. At 24-month follow-up, the patient was pain free and had returned to full activity including weightlifting but had not returned to strongman competition.This is the first report of simultaneous acute full thickness ruptures of the rotator cuff and distal biceps tendon. This case report underscores the importance of a complete physical examination and a high index of suspicion for additional concomitant injuries, particularly in athletes with unusually high stresses to the body. Copyright 2010, SLACK Incorporated.

  16. Surgical treatment of partial biceps tendon ruptures at the elbow.

    Science.gov (United States)

    Dellaero, David T; Mallon, William J

    2006-01-01

    We present the treatment and results of a consecutive series of 7 patients (mean age, 42.7 years) with partial ruptures of the distal biceps tendon. All injuries occurred as the result of either heavy labor or weightlifting. Diagnosis in all cases was made with magnetic resonance imaging. After failure of conservative therapy, the patients were treated with repair of the distal biceps tendon. Mean follow-up was 30.6 months (range, 25-39 months). Results were uniformly good, with all patients satisfied with the outcome. All patients maintained their preoperative range of motion, with none reporting significant postoperative pain. The only complication was transient neurapraxias of the lateral antebrachial cutaneous nerve in 2 cases. We conclude that patients presenting with chronic pain in the cubital fossa should be evaluated for possible partial biceps tendon tear. If the diagnosis of partial tendon tear is made, surgical repair is a safe and effective method of treatment.

  17. Acute distal biceps rupture in an adolescent weightlifter on chronic steroid suppression: a case report.

    Science.gov (United States)

    Ding, David Y; LaMartina, Joey A; Zhang, Alan L; Pandya, Nirav K

    2016-09-01

    Distal biceps tendon ruptures are uncommon events in the adult population and exceedingly rare in the adolescent population. To the best of our knowledge, this is the first and only report of a distal biceps tendon rupture in an adolescent with a history of chronic corticosteroid suppression. We present a case of a 17-year-old male on chronic corticosteroid suppression who underwent a successful distal biceps tendon repair after an acute rupture following weightlifting. At the 1-year follow-up, the patient reports full range of motion and strength, and is able to return to his preinjury activity level with sports and weightlifting. Acute distal biceps ruptures are uncommon injuries in the pediatric population, but may occur in conjunction with chronic corticosteroid use. Anatomic repair, when possible, can restore function and strength. level IV, case report.

  18. MR imaging findings in flexed abducted supinated (FABS) position and clinical presentation following refixation of distal biceps tendon rupture using bioabsorbable suture anchors

    International Nuclear Information System (INIS)

    Marnitz, T.; Steffen, I.G.; Denecke, T.; Elgeti, F.A.; Spiegel, D.; Hug, K.; Hueper, M.; Gerhardt, C; Greiner, S.; Scheibel, M.

    2012-01-01

    Purpose: To correlate MRI findings after suture anchor repair of distal biceps tendons with symptoms. Materials and Methods: 24 men with 25 distal biceps tendon ruptures (one bilateral) treated with suture anchor repair were retrospectively included. Follow-up after a mean of 31 months (range, 12 - 74) included clinical examination and MRI. The pain level and flexion strength compared to the uninvolved arm were recorded. MRI was performed at 1.5 T obtaining FABS position images (both elbows in 7 patients) and evaluated for artifacts, signal abnormalities, and rerupture by two experienced readers in consensus and blinded to symptoms. Pain and loss of flexion strength > 20 % were tested against MRI findings as dichotomous data using Fisher's exact chi-square tests (p 0.05). There was a 2.7-fold mean increase of the tendon cross-sectional area on the repaired side compared to the uninvolved contralateral tendon (p = 0.02). Conclusion: We found good MRI visualization of postoperative tendons, but no correlation between symptoms and MRI signal abnormalities or rerupture. The increase in caliber of the repaired tendon might promote an impingement in pronation. (orig.)

  19. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  20. Calcific tendinitis of the long head of the biceps brachii distal to the glenohumeral joint: plain film radiographic findings.

    Science.gov (United States)

    Goldman, A B

    1989-11-01

    Calcific tendinitis is a painful condition related to deposition of hydroxyapatite crystals; it favors large joints. The shoulder, specifically the tendons of the rotator cuff and the insertion of the long head of the biceps on the superior glenoid rim, is a well-recognized location for this abnormality. The purpose of this article is to describe a second site of calcific tendinitis of the biceps, distal to the joint and corresponding to the junction of the tendon and muscle. Radiographs in 119 cases of calcific tendinitis of the shoulder, obtained between 1980 and 1988, were reviewed. Twenty had calcific tendinitis in the region of the tendon of the long head of the biceps (nine at the glenoid insertion and 11 adjacent to the humeral shaft). All 11 patients with calcific tendinitis at the more distal site had a small, homogeneous deposit adjacent to the proximal humeral shaft. The densities in these 11 cases followed the normal course of the tendon of the long head of the biceps and were therefore medial to the proximal humeral shaft on the internal rotation view, lateral to the proximal humeral shaft on the external rotation view, and anterior to the proximal humeral shaft on the axillary projection. The major differential diagnosis of calcific tendinitis of the tendon of the long head of the biceps is loose bodies trapped in the biceps tendon sheath. Although the position of the soft-tissue densities in these two entities is similar, loose bodies have an appearance of bone, and their source (degenerative arthritis or recurrent dislocations) is usually apparent. A site of calcific tendinitis distal to the glenohumeral joint that is detectable on plain films is reviewed. Accurate diagnosis depends on understanding the anatomy of the tendon of the long head of the biceps brachii. The clinical charts of the 11 patients also are summarized, with emphasis on the association between the roentgen finding and bicipital tendinitis and impingement syndrome.

  1. Distal biceps brachii tendon repair: a systematic review of patient outcome determination using modified Coleman methodology score criteria.

    Science.gov (United States)

    Nyland, John; Causey, Brandon; Wera, Jeff; Krupp, Ryan; Tate, David; Gupta, Amit

    2017-07-01

    This systematic literature review evaluated the methodological research design quality of studies that evaluated patient outcomes following distal biceps brachii tendon repair and developed evidence-based recommendations for future patient clinical outcomes research. Following the preferred reporting items for systematic reviews and meta-analyses criteria, and using "biceps brachii", "tendon", "repair" and "outcome assessment" search terms, the CINAHL, Academic Search Premier and MEDLINE databases were searched from January 1960-October 2015. The modified Coleman methodology score (MCMS) served as the primary outcome measure. Descriptive statistical analysis was performed for composite and component MCMS and for patient outcome assessment methodology use frequency. A total of 93 studies were evaluated. Overall MCMS was low (57.1 ± 14). Only 12 (12.9 %) had prospective cohort or randomized controlled trial designs. There was a moderate relationship between publication year and MCMS (r = 0.53, P research study methodological scores improved on average since 2008, generally low MCMS scores, retrospective designs, lack of eccentric elbow flexor or supinator strength testing, and poorly described surgical and rehabilitation descriptions remain commonplace. These findings decrease clinical study validity and generalizability. III.

  2. Cadaveric Study of Insertional Anatomy of Distal Biceps Tendon and its Relationship to the Dynamic Proximal Radioulnar Space.

    Science.gov (United States)

    Bhatia, Deepak N; Kandhari, Vikram; DasGupta, Bibhas

    2017-01-01

    To quantify and assess the relationship between the insertional dimensions of the distal biceps tendon (DBT) and radioulnar space (RUS) in 3 rotational positions. We hypothesized that in all positions RUS would be adequate for the DBT and would remain adequate even after an incremental increase (1 to 3 mm) in tendon thickness. Eleven fresh-frozen cadaveric elbows were dissected; DBT dimensions and bicipital tuberosity measurements were performed and insertional footprints were quantified using a distal biceps footprint index. The RUS was measured at 3 levels of the bicipital tuberosity and in 3 positions of forearm rotation. We performed statistical analysis to analyze differences in RUS (positional and inter-level). In addition, significant differences between DBT thickness (native and incremental) and RUS were analyzed to identify potential sites of radioulnar impingement. The DBT had a mean length of 92 mm; thickness ranged from 2.9 to 6.1 mm. Three variations in DBT insertional footprint were observed and quantified. The RUS linear distance reduced significantly from a supinated to a pronated position at each of 3 bicipital tuberosity levels; the reduction was statistically significant at the lower tuberosity level (45%). Pronation RUS distance was adequate for native DBT thickness and was significantly less when DBT thickness increased by 2 and 3 mm. Radioulnar space reduces significantly from the supinated to the pronated position and is most evident in the lower aspect of the tuberosity. In addition, the RUS in pronation is inadequate for incremental increases in DBT thickness. Postoperative DBT impingement in the RUS may be prevented by avoiding techniques that increase the thickness of the tendon and by using a reattachment site at the proximal aspect of the tuberosity. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Disorders of the long head of the biceps tendon.

    Science.gov (United States)

    Sethi, N; Wright, R; Yamaguchi, K

    1999-01-01

    Without a clear understanding of the functional role of the biceps tendon, treatment recommendations have been a subject of controversy. An objective review of the available information would suggest that some humeral head stability may be imparted through the tendon. However, the magnitude of this function is likely to be small and possibly insignificant. In contrast, the symptomatic significance of the long head of the biceps is less controversial, and it has become increasingly recognized as an important source of persistent shoulder pain when not specifically addressed. When present, persistent pain from the long head of the biceps is likely to have more negative functional consequences than loss of the tendon itself. Given these concerns, evaluation and treatment of patients with long head of the biceps disorders should be individualized, based on the likelihood that biceps-related pain will resolve. Although not universally accepted, we recommend tenodesis of the long head of the biceps in those cases in which there are either chronic inflammatory or structural changes, which would make it unlikely that the pain would resolve. These clinical situations in which tenodesis would be required include greater than 25% partial thickness tearing of the tendon, chronic atrophic changes of the tendon, any luxation of the biceps tendon from the bicipital groove, any disruption of associated bony or ligamentous anatomy of the bicipital groove that would make autotenodesis likely (i.e., 4-part fracture), and any significant reduction or atrophy of the size of the tendon that is more than 25% of the normal tendon width. Relative indications for biceps tenodesis also include biceps disease in the context of a failed decompression for rotator cuff tendinitis. It should be emphasized that routine tenodesis is not recommended during operative treatment for the rotator cuff. Rather, we avoid tenodesis whenever it is believed that inflammatory changes to the biceps tendon are

  4. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    Directory of Open Access Journals (Sweden)

    Streit JJ

    2015-03-01

    Full Text Available Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Methods: Twenty-six consecutive patients (mean age 45.4±13.7 years underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Results: Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Conclusion: Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body. Keywords: biceps tendinitis, biceps tendinopathy, tenosynovium, anterior shoulder pain, long head biceps

  5. Is nonoperative management of partial distal biceps tears really successful?

    Science.gov (United States)

    Bauer, Tyler M; Wong, Justin C; Lazarus, Mark D

    2018-04-01

    The current treatment of partial distal biceps tears is a period of nonoperative management, followed by surgery, if symptoms persist. Little is known about the success rate and outcomes of nonoperative management of this illness. We identified 132 patients with partial distal biceps tears through an International Classification of Diseases, Ninth Revision code query of our institution's database. Patient records were reviewed to abstract demographic information and confirm partial tears of the distal biceps tendon based on clinical examination findings and confirmatory magnetic resonance imaging (MRI). Seventy-four patients completed an outcome survey. In our study, 55.7% of the contacted patients who tried a nonoperative course (34 of 61 patients) ultimately underwent surgery, and 13 patients underwent immediate surgery. High-need patients, as defined by occupation, were more likely to report that they recovered ideally if they underwent surgery, as compared with those who did not undergo surgery (odds ratio, 11.58; P = .0138). For low-need patients, the same analysis was not statistically significant (P = .139). There was no difference in satisfaction scores between patients who tried a nonoperative course before surgery and those who underwent immediate surgery (P = .854). An MRI-diagnosed tear of greater than 50% was a predictor of needing surgery (odds ratio, 3.0; P = .006). This study has identified clinically relevant information for the treatment of partial distal biceps tears, including the following: the failure rate of nonoperative treatment, the establishment of MRI percent tear as a predictor of failing nonoperative management, the benefit of surgery for the high-need occupational group, and the finding that nonoperative management does not negatively affect outcome if subsequent surgery is necessary. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Evaluation of the Effusion within Biceps Long Head Tendon Sheath Using Ultrasonography

    Science.gov (United States)

    Park, In; Lee, Hyo-Jin; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Kwang-Yeol; Park, Kwang-Sun

    2015-01-01

    Background Many shoulder diseases are related to glenohumeral joint synovitis and effusion. The purpose of the present study is to detect effusion within the biceps long head tendon sheath as the sign of glenohumeral joint synovitis using ultrasonography, and to evaluate the clinical meaning of effusion within the biceps long head tendon sheath. Methods A consecutive series of 569 patients who underwent ultrasonography for shoulder pain were reviewed retrospectively and ultimately, 303 patients were included. The authors evaluated the incidence and amount of the effusion within the biceps long head tendon sheath on the ultrasonographic short axis view. Furthermore, the authors evaluated the correlation between the amount of effusion within the biceps long head tendon sheath and the range of motion and the functional score. Results The effusion within the biceps long head tendon sheath was detected in 58.42% of the patients studied: 69.23% in adhesive capsulitis, 56.69% in rotator cuff tear, 41.03% in calcific tendinitis, and 33.33% in biceps tendinitis. The average amount of the effusion within the biceps long head tendon sheath was 1.7 ± 1.6 mm, and it was measured to be the largest in adhesive capsulitis. The amount of effusion within biceps long head tendon sheath showed a moderate to high degree of correlation with the range of motion, and a low degree of correlation with the functional score and visual analogue scale for pain in each type of shoulder disease. Conclusions The effusion within the biceps long head tendon sheath is closely related to the range of motion and clinical scores in patients with painful shoulders. Ultrasonographic detection of the effusion within the biceps long head tendon sheath might be a simple and easy method to evaluate shoulder function. PMID:26330958

  7. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  8. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium.

    Science.gov (United States)

    Streit, Jonathan J; Shishani, Yousef; Rodgers, Mark; Gobezie, Reuben

    2015-01-01

    Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon and synovial sheath in order to compare those findings to known histologic changes seen in other tendinopathies. Twenty-six consecutive patients (mean age 45.4±13.7 years) underwent an open subpectoral biceps tenodesis for anterior shoulder pain localized to the bicipital groove. Excised tendons were sent for histologic analysis. Specimens were graded using a semiquantitative scoring system to evaluate tenocyte morphology, the presence of ground substance, collagen bundle characteristics, and vascular changes. Chronic inflammation was noted in only two of 26 specimens, and no specimen demonstrated acute inflammation. Tenocyte enlargement and proliferation, characterized by increased roundness and size of the cell and nucleus with proteoglycan matrix expansion and myxoid degenerative changes, was found in all 26 specimens. Abundant ground substance, collagen bundle changes, and increased vascularization were visualized in all samples. Anterior shoulder pain attributed to the biceps tendon does not appear to be due to an inflammatory process in most cases. The histologic findings of the extra-articular portion of the LHB tendon and synovial sheath are similar to the pathologic findings in de Quervain tenosynovitis at the wrist, and may be due to a chronic degenerative process similar to this and other tendinopathies of the body.

  9. Bilateral congenital absence of the long head of the biceps tendon

    Energy Technology Data Exchange (ETDEWEB)

    Koplas, Monica C. [Cleveland Clinic, Imaging Institute/HB6, Cleveland, OH (United States); Winalski, Carl S. [Cleveland Clinic, Imaging Institute/A21, Cleveland, OH (United States); Ulmer, William H. [Orthopedic and Spine Specialists, York, PA (United States); Recht, Michael [NYU Langone Medical Center, Department of Radiology, New York, NY (United States)

    2009-07-15

    Absence of the long head of the biceps tendon is a rare anomaly particularly when it occurs bilaterally. We present the magnetic resonance and arthroscopy findings in a patient with bilateral congenital absence of the long head of the biceps who presented with bilateral shoulder pain. Identification of a shallow or absent intertubercular groove may aid in differentiating congenital absence of the long head of the biceps from a traumatic tendon rupture. (orig.)

  10. Tendinopathy of the long head of the biceps tendon: histopathologic analysis of the extra-articular biceps tendon and tenosynovium

    OpenAIRE

    Shishani, Yousef; Streit,Jonathan; Rodgers,Mark; Gobezie,Reuben

    2015-01-01

    Jonathan J Streit,1 Yousef Shishani,1 Mark Rodgers,2 Reuben Gobezie1 1The Cleveland Shoulder Institute, 2Department of Pathology, University Hospitals of Cleveland, Cleveland, OH, USA Background: Bicipital tendinitis is a common cause of anterior shoulder pain, but there is no evidence that acute inflammation of the extra-articular long head of the biceps (LHB) tendon is the root cause of this condition. We evaluated the histologic findings of the extra-articular portion of the LHB tendon an...

  11. Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome

    Energy Technology Data Exchange (ETDEWEB)

    Alemann, Guillaume; Dietsch, Emmanuel [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Gallinet, David; Obert, Laurent [University Hospital of Besancon, Department of Orthopedic Surgery, Besancon (France); Kastler, Bruno; Aubry, Sebastien [University Hospital of Besancon, Department of Musculoskeletal Imaging, Besancon (France); Franche Comte University, I4S Laboratory-EA 4268-IFR 133, Besancon (France)

    2015-05-01

    Objectives were to study the MRI appearance of the repaired distal biceps tendon (DBT), anatomically reinserted, and to search for a correlation between tendon measurements and functional results. Twenty-five patients (mean age, 49 ± 4.9 years old) who benefited from 3-T MRI follow-up of the elbow after surgical reinsertion of the DBT were retrospectively included and compared to a control group (n = 25; mean age, 48 ± 10 years old). MRI was performed during the month of clinical follow-up and on average 22 months after surgery. Delayed complications (secondary avulsion, new rupture), intratendinous osteoma, tendinous signal on T1-weighted (T1{sub w}) and fat-suppressed proton density-weighted (FS-PD{sub w}) images as well as DBT measurements were recorded. The maximum isometric elbow flexion strength (MEFS) and range of motion of the elbow were assessed. Repaired DBT demonstrated a heterogeneous but normally fibrillar structure. Its low T1{sub w} signal was less pronounced than that of normal tendons, and the FS-PD{sub W} image signal was similar to that of T1{sub w} images. MRI detected seven osteomas (Se = 53 % vs. plain radiography), one textiloma and one secondary avulsion. Repaired DBT measurements were significantly correlated with MEFS (dominant arm R2: 0.38; nondominant arm R2: 0.54); this correlation involved the insertion surface (Δ = -75.7 mm{sup 2}, p = 0.046), transverse diameter (Δ = -2.6 mm, p = 0.018), anteroposterior diameter at the level of the radial head (Δ = -3.9 mm, p = 0.001) and DBT cross-sectional area (Δ = -50.2 mm{sup 2}, p = 0.003). The quality of functional outcome after anatomical elbow rehabilitation of DBT correlates with the extent of tendinous hypertrophy during the healing process. (orig.)

  12. Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome

    International Nuclear Information System (INIS)

    Alemann, Guillaume; Dietsch, Emmanuel; Gallinet, David; Obert, Laurent; Kastler, Bruno; Aubry, Sebastien

    2015-01-01

    Objectives were to study the MRI appearance of the repaired distal biceps tendon (DBT), anatomically reinserted, and to search for a correlation between tendon measurements and functional results. Twenty-five patients (mean age, 49 ± 4.9 years old) who benefited from 3-T MRI follow-up of the elbow after surgical reinsertion of the DBT were retrospectively included and compared to a control group (n = 25; mean age, 48 ± 10 years old). MRI was performed during the month of clinical follow-up and on average 22 months after surgery. Delayed complications (secondary avulsion, new rupture), intratendinous osteoma, tendinous signal on T1-weighted (T1 w ) and fat-suppressed proton density-weighted (FS-PD w ) images as well as DBT measurements were recorded. The maximum isometric elbow flexion strength (MEFS) and range of motion of the elbow were assessed. Repaired DBT demonstrated a heterogeneous but normally fibrillar structure. Its low T1 w signal was less pronounced than that of normal tendons, and the FS-PD W image signal was similar to that of T1 w images. MRI detected seven osteomas (Se = 53 % vs. plain radiography), one textiloma and one secondary avulsion. Repaired DBT measurements were significantly correlated with MEFS (dominant arm R2: 0.38; nondominant arm R2: 0.54); this correlation involved the insertion surface (Δ = -75.7 mm 2 , p = 0.046), transverse diameter (Δ = -2.6 mm, p = 0.018), anteroposterior diameter at the level of the radial head (Δ = -3.9 mm, p = 0.001) and DBT cross-sectional area (Δ = -50.2 mm 2 , p = 0.003). The quality of functional outcome after anatomical elbow rehabilitation of DBT correlates with the extent of tendinous hypertrophy during the healing process. (orig.)

  13. Fibroma of the tendon sheath of the long head of the biceps tendon

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Shahabpour, Maryam; Isacker, Tom van; Lenchik, Leon; Caillie, Marie-Astrid van

    2014-01-01

    Fibroma of the tendon sheath is a benign tumor that is less common than giant cell tumor of the tendon sheath. Both tumors may present as a painless, slowly enlarging mass. Radiological findings may be similar for both tumors. Histologically, fibroma of the tendon sheath lacks the hemosiderin-laden macrophages that are typical for giant cell tumor of the tendon sheath. We report on a 49-year-old woman with fibroma of the tendon sheath of the long head of the biceps tendon. In our case, on MR images, we observed band-like hypointense areas centrally in the tumor, mild patchy contrast enhancement, and most importantly, no decrease of signal intensity on gradient echo images. These characteristics reflected histological findings. (orig.)

  14. Degeneration of the long biceps tendon: comparison of MRI with gross anatomy and histology.

    Science.gov (United States)

    Buck, Florian M; Grehn, Holger; Hilbe, Monika; Pfirrmann, Christian W A; Manzanell, Silvana; Hodler, Jürg

    2009-11-01

    The objective of our study was to relate alterations in biceps tendon diameter and signal on MR images to gross anatomy and histology. T1-weighted, T2-weighted fat-saturated, and proton density-weighted fat-saturated spin-echo sequences were acquired in 15 cadaveric shoulders. Biceps tendon diameter (normal, flattened, thickened, and partially or completely torn) and signal intensity (compared with bone, fat, muscle, and joint fluid) were graded by two readers independently and in a blinded fashion. The distance of tendon abnormalities from the attachment at the glenoid were noted in millimeters. MRI findings were related to gross anatomic and histologic findings. On the basis of gross anatomy, there were six normal, five flattened, two thickened, and two partially torn tendons. Reader 1 graded nine diameter changes correctly, missed two, and incorrectly graded four. The corresponding values for reader 2 were seven, one, and five, respectively, with kappa = 0.75. Histology showed mucoid degeneration (n = 13), lipoid degeneration (n = 7), and fatty infiltration (n = 6). At least one type of abnormality was found in each single tendon. Mucoid degeneration was hyperintense compared with fatty infiltration on T2-weighted fat-saturated images and hyperintense compared with magic-angle artifacts on proton density-weighted fat-saturated images. MRI-based localization of degeneration agreed well with histologic findings. Diameter changes are specific but not sensitive in diagnosing tendinopathy of the biceps tendon. Increased tendon signal is most typical for mucoid degeneration but should be used with care as a sign of tendon degeneration.

  15. Assessment of instability of the long head of the biceps tendon by MRI

    International Nuclear Information System (INIS)

    Spritzer, C.E.; Collins, A.J.; Cooperman, A.; Speer, K.P.

    2001-01-01

    Objective. To determine whether MRI can identify instability of the long head of the biceps tendon (LBT) in the rotator interval.Design and patients. A retrospective review was carried out of 19 patients, all arthroscopically examined, nine of whom had surgically confirmed instability of the LBT.Results. A LBT perched on the lesser tuberosity correctly indicated all nine cases of instability with one false positive. In six of seven cases where the LBT was oval in shape, no instability of the biceps tendon existed, whereas LBT instability was present in eight of 12 patients with a flat long head of the biceps tendon. In seven of eight acutely angled intertubercular sulci there was no instability of the LBT while eight of 11 obtusely angled sulci were associated with LBT instability. By consensus impression, instability of the LBT could be determined with 67% sensitivity, 90% specificity, 86% positive predictive value, and 75% negative predictive value.Conclusions. A flat LBT perched on the lesser tuberosity with an obtusely angled intertubercular sulcus suggests the diagnosis of instability of the LBT in the correct clinical setting. (orig.)

  16. Common Peroneal Nerve Palsy with Multiple-Ligament Knee Injury and Distal Avulsion of the Biceps Femoris Tendon

    Directory of Open Access Journals (Sweden)

    Takeshi Oshima

    2015-01-01

    Full Text Available A multiple-ligament knee injury that includes posterolateral corner (PLC disruption often causes palsy of the common peroneal nerve (CPN, which occurs in 44% of cases with PLC injury and biceps femoris tendon rupture or avulsion of the fibular head. Approximately half of these cases do not show functional recovery. This case report aims to present a criteria-based approach to the operation and postoperative management of CPN palsy that resulted from a multiple-ligament knee injury in a 22-year-old man that occurred during judo. We performed a two-staged surgery. The first stage was to repair the injuries to the PLC and biceps femoris. The second stage involved anterior cruciate ligament reconstruction. The outcomes were excellent, with a stable knee, excellent range of motion, and improvement in the palsy. The patient was able to return to judo competition 27 weeks after the injury. To the best of our knowledge, this is the first case report describing a return to sports following CPN palsy with multiple-ligament knee injury.

  17. US Findings of Biceps Tendinitis: Cross Sectional Area Measurements of Long Head of Biceps Brachii

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jong Soo; Seo, Kyung Mook; Lee, Hwa Yeon; Song, In Sup [ChungAng University College of Medicine, Seoul (Korea, Republic of); Yoo, Seung Min [Bundang Cha Hospital, Bundang (Korea, Republic of)

    2009-12-15

    The purpose of this study was to describe typical sonographic findings in patients with biceps tendinitis. Seventy five patients who had been clinically diagnosed with biceps tendinitis were included. Of the 75, 37 were male, 38 were female, and their mean age was 56 {+-} 9.74. The patients complained of shoulder pain and ultrasonography was performed for bilateral shoulders in all patients. The cross sectional area of the biceps tendon was measured. The status of fluid collection around the biceps tendon and accompanying rotator cuff disease were also investigated. The cross sectional areas of the diseased biceps tendon were 0.18 {+-} 0.09 cm2 (range: 0.07-0.42), and the areas of the normal side was 0.11 {+-} 0.05 cm2 (0.03-0.24). The cross sectional area of the diseased biceps tendon was 0.075 {+-} 0.062 cm2 greater, on average, than the uninvolved site (p < 0.01). Thirty six patients(48%) had fluid collection around the inflamed biceps tendon, and 30 patients had accompanied rotator cuff disease. During US examination of the shoulder in patients complaining of shoulder pain, if the cross sectional area of the biceps tendon in the painful shoulder is asymmetrically and larger than the contralateral tendon, biceps tendonitis is suggested

  18. US Findings of Biceps Tendinitis: Cross Sectional Area Measurements of Long Head of Biceps Brachii

    International Nuclear Information System (INIS)

    Shin, Jong Soo; Seo, Kyung Mook; Lee, Hwa Yeon; Song, In Sup; Yoo, Seung Min

    2009-01-01

    The purpose of this study was to describe typical sonographic findings in patients with biceps tendinitis. Seventy five patients who had been clinically diagnosed with biceps tendinitis were included. Of the 75, 37 were male, 38 were female, and their mean age was 56 ± 9.74. The patients complained of shoulder pain and ultrasonography was performed for bilateral shoulders in all patients. The cross sectional area of the biceps tendon was measured. The status of fluid collection around the biceps tendon and accompanying rotator cuff disease were also investigated. The cross sectional areas of the diseased biceps tendon were 0.18 ± 0.09 cm2 (range: 0.07-0.42), and the areas of the normal side was 0.11 ± 0.05 cm2 (0.03-0.24). The cross sectional area of the diseased biceps tendon was 0.075 ± 0.062 cm2 greater, on average, than the uninvolved site (p < 0.01). Thirty six patients(48%) had fluid collection around the inflamed biceps tendon, and 30 patients had accompanied rotator cuff disease. During US examination of the shoulder in patients complaining of shoulder pain, if the cross sectional area of the biceps tendon in the painful shoulder is asymmetrically and larger than the contralateral tendon, biceps tendonitis is suggested

  19. Brachial biceps tendon injuries in young female high-level tennis players.

    Science.gov (United States)

    Tsur, A; Gillson, S

    2000-06-01

    To evaluate brachial biceps tendon lesions in four young female tennis players who complained about anterior shoulder pain on their dominant side. Medical and sport's activity history, palpation of the painful zone, Ghilchrist (palm-up) test, and brachial biceps contraction against resistance were performed. The two girls who suffered from mild tenderness in the bicipital groove and over the anterior aspect of the upper arm and the shoulder joint, had tendinitis of the long biceps head. The two girls who suffered from severe tenderness just under the groove, had a partial tear in the long head of the biceps. Ghilchrist test was positive in all girls. Tennis players can have shoulder pain without clear history of trauma. Pain occurred probably as a result of technical errors or use of inadequate equipment.

  20. Rupture Following Biceps-to-Triceps Tendon Transfer in Adolescents and Young Adults With Spinal Cord Injury:

    Science.gov (United States)

    Merenda, Lisa A.; Rutter, Laure; Curran, Kimberly; Kozin, Scott H.

    2012-01-01

    Background: Tendon transfer surgery can restore elbow extension in approximately 70% of persons with tetraplegia and often results in antigravity elbow extension strength. However, we have noted an almost 15% rupture/attenuation rate. Objective: This investigation was conducted to analyze potential causes in adolescents/young adults with spinal cord injury (SCI) who experienced tendon rupture or attenuation after biceps-to-triceps transfer. Methods: Medical charts of young adults with SCI who underwent biceps-to-triceps transfer and experienced tendon rupture or attenuation were reviewed. Data collected by retrospective chart review included general demographics, surgical procedure(s), use and duration of antibiotic treatment, time from tendon transfer surgery to rupture/attenuation, and method of diagnosis. Results: Twelve subjects with tetraplegia (mean age, 19 years) who underwent biceps-to-triceps reconstruction with subsequent tendon rupture or attenuation were evaluated. Mean age at time of tendon transfer was 18 years (range, 14-21 years). A fluoroquinolone was prescribed for 42% (n=5) of subjects. Tendon rupture was noted in 67% (n=8), and attenuation was noted in 33% (n=4). Average length of time from surgery to tendon rupture/attenuation was 5.7 months (range, 3-10 months). Conclusion: Potential contributing causes of tendon rupture/attenuation after transfer include surgical technique, rehabilitation, co-contraction of the transfer, poor patient compliance, and medications. In this cohort, 5 subjects were prescribed fluoroquinolones that have a US Food and Drug Administration black box concerning tendon ruptures. Currently, all candidates for upper extremity tendon transfer reconstruction are counseled on the effects of fluoroquinolones and the potential risk for tendon rupture. PMID:23459326

  1. Biceps tendinitis and subluxation.

    Science.gov (United States)

    Patton, W C; McCluskey, G M

    2001-07-01

    Since the 17th century, the long head of the biceps tendon as a source of shoulder pain and its functional significance has been a source of debate. Although the term tendinitis is commonly used, overuse tendon injuries infrequently demonstrate inflammatory cells; instead, degenerative changes resulting from the failure of self-repair usually are found. Bicipital tendinitis or bicipital tenosynovitis is most often secondary to impingement beneath the coracoacromical arch. Primary bicipital tendinitis and tendinitis secondary to instability are possible, however. Through a careful history, physical examination, and appropriate imaging studies, the clinician can establish the diagnosis of disorders of the biceps tendon Arthroscopic evaluation greatly improves the diagnosis and treatment of biceps tendon and related shoulder pathology. Although the exact functional role of the biceps tendon remains incompletely defined, a growing body of evidence supports its role as a stabilizer of the glenohumeral joint. This stabilizing function should be incorporated into the treatment of biceps tendon disorders. Routine tenodesis has been replaced by a more individualized approach, taking into consideration physiologic age, activity level, expectations, and exact shoulder pathology present. New repair techniques are under development, and preservation of the biceps-labral complex is now preferred when possible.

  2. Diagnosis and treatment of biceps tendinitis and tendinosis.

    Science.gov (United States)

    Churgay, Catherine A

    2009-09-01

    Biceps tendinitis is inflammation of the tendon around the long head of the biceps muscle. Biceps tendinosis is caused by degeneration of the tendon from athletics requiring overhead motion or from the normal aging process. Inflammation of the biceps tendon in the bicipital groove, which is known as primary biceps tendinitis, occurs in 5 percent of patients with biceps tendinitis. Biceps tendinitis and tendinosis are commonly accompanied by rotator cuff tears or SLAP (superior labrum anterior to posterior) lesions. Patients with biceps tendinitis or tendinosis usually complain of a deep, throbbing ache in the anterior shoulder. Repetitive overhead motion of the arm initiates or exacerbates the symptoms. The most common isolated clinical finding in biceps tendinitis is bicipital groove point tenderness with the arm in 10 degrees of internal rotation. Local anesthetic injections into the biceps tendon sheath may be therapeutic and diagnostic. Ultrasonography is preferred for visualizing the overall tendon, whereas magnetic resonance imaging or computed tomography arthrography is preferred for visualizing the intra-articular tendon and related pathology. Conservative management of biceps tendinitis consists of rest, ice, oral analgesics, physical therapy, or corticosteroid injections into the biceps tendon sheath. Surgery should be considered if conservative measures fail after three months, or if there is severe damage to the biceps tendon.

  3. Nonoperative treatment of distal biceps brachii musculotendinous partial rupture: a report of two cases.

    Science.gov (United States)

    López-Zabala, I; Fernández-Valencia, J A

    2013-01-01

    Musculotendinous ruptures of the distal biceps brachii are extremely rare injuries whose clinical presentation is similar to distal biceps avulsion. We describe two cases of patients who suffered a distal biceps brachii musculotendinous partial rupture. The first patient was playing soccer as goalkeeper and experienced sudden pain while throwing the ball overhead with his left arm. The second patient experienced sudden pain while weightlifting with his right arm. The mechanism of injury was the same in the two cases, as both involved glenohumeral elevation with elbow extension and forearm supination. Neither of these two patients underwent surgical repair or rehabilitation, and both had perfect scores of 100 on the Mayo Clinic Performance Index for the Elbow at one-year followup.

  4. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex.

    Science.gov (United States)

    Taylor, Samuel A; Khair, M Michael; Gulotta, Lawrence V; Pearle, Andrew D; Baret, Nikolas J; Newman, Ashley M; Dy, Christopher J; O'Brien, Stephen J

    2015-02-01

    The purpose of this study was to define the limits of diagnostic glenohumeral arthroscopy and determine the prevalence and frequency of hidden extra-articular "bicipital tunnel" lesions among chronically symptomatic patients. Eight fresh-frozen cadaveric specimens underwent diagnostic glenohumeral arthroscopy with percutaneous tagging of the long head of the biceps tendon (LHBT) during maximal tendon excursion. The percentage of visualized LHBT was calculated relative to the distal margin of subscapularis tendon and the proximal margin of the pectoralis major tendon. Then, a retrospective review of 277 patients who underwent subdeltoid transfer of the LHBT to the conjoint tendon were retrospectively analyzed for lesions of the biceps-labral complex. Lesions were categorized by anatomic location (inside, junctional, or bicipital tunnel). Inside lesions were labral tears. Junctional lesions were LHBT tears visualized during glenohumeral arthroscopy. Bicipital tunnel lesions were extra-articular lesions hidden from view during standard glenohumeral arthroscopy. Seventy-eight percent of LHBT were visualized relative to the distal margin of the subscapularis tendon and only 55% relative to the proximal margin of the pectoralis major tendon. No portion of the LHBT inferior to the subscapularis tendon was visualized. Forty-seven percent of patients had hidden bicipital tunnel lesions. Scarring was most common and accounted for 48% of all such lesions. Thirty-seven percent of patients had multiple lesion locations. Forty-five percent of patients with junctional lesions also had hidden bicipital tunnel lesions. The only offending lesion was in the bicipital tunnel for 18% of patients. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex because it visualizes only 55% of the LHBT relative to the proximal margin of the pectoralis major tendon and did not identify extra-articular bicipital tunnel lesions present in 47% of chronically

  5. Physical examination tests and imaging studies based on arthroscopic assessment of the long head of biceps tendon are invalid.

    Science.gov (United States)

    Jordan, Robert W; Saithna, Adnan

    2017-10-01

    The aim of this study was to evaluate whether glenohumeral arthroscopy is an appropriate gold standard for the diagnosis of long head of biceps (LHB) tendon pathology. The objectives were to evaluate whether the length of tendon that can be seen at arthroscopy allows visualisation of areas of predilection of pathology and also to determine the rates of missed diagnoses at arthroscopy when compared to an open approach. A systematic review of cadaveric and clinical studies was performed. The search strategy was applied to MEDLINE, PubMed and Google Scholar databases. All relevant articles were included. Critical appraisal of clinical studies was performed using a validated quality assessment scale. Five articles were identified for inclusion in the review. This included both clinical and cadaveric studies. The overall population comprised 18 cadaveric specimens and 575 patients. Out of the five included studies, three reported the length of LHB tendon visualised during arthroscopy and four reported the rate of missed LHB diagnosis. Cadaveric studies showed that the use of a hook probe allowed arthroscopic visualisation of between 34 and 48 % of the overall length of the LHB. In the clinical series, the rate of missed diagnoses at arthroscopy when compared to open exploration ranged between 33 and 49 %. Arthroscopy allows visualisation of only a small part of the extra-articular LHB tendon. This leads to a high rate of missed pathology in the distal part of the tendon. Published figures for sensitivities and specificities of common physical examination and imaging tests for LHB pathology that are based on arthroscopy as the gold standard are therefore invalid. In clinical practice, it is important to note that a "negative" arthroscopic assessment does not exclude a lesion of the LHB tendon as this technique does not allow visualisation of common sites of distal pathology. IV.

  6. [Bursitis with severe tendon and muscle necrosis on the lateral stifle area in cattle].

    Science.gov (United States)

    Nuss, K; Räber, M; Sydler, T; Muggli, E; Hässig, M; Guscetti, F

    2011-11-01

    In 21 animals, chronic swelling on the lateral aspect of the stifle also known as «perigonitis», «stable-syndrome» or «bursitis bicipitalis femoris» were evaluated. Ultrasonography showed increased fluid in the distal subtendinous bursa of the biceps femoris muscle and structural changes in the tendons, muscles, subcutis and fasciae. Soft tissue swelling and an irregular contour of the lateral tibial condyle were typical signs on radiographs. Macroscopic changes were found at the insertion of the biceps femoris muscle, the distal subtendinous bursa of the biceps femoris muscle, the lateral collateral ligament of the stifle, the origin of muscles on the lateral femoral condyle and the lateral tibial condyle. They mainly consisted of tendon and muscle tissue necrosis with granulation tissue. Histology revealed areas of coagulation necrosis in tendons and ligaments, in which occasionally Onchocerca spp. were seen. The severity of lesions correlated well with the clinical signs, which were associated with a poor prognosis in advanced cases.

  7. Rupture of the long tendon of the biceps brachi muscle. An unusual case related to use of the pneumatic tourniquet.

    Science.gov (United States)

    Logel, R J

    1976-01-01

    Tourniquet paralysis, arterial spasm, aneurysm formation, and the post-ischemic hand syndrome are all complications of penumatic tourniquet use in surgery of the extremities. This is a case report of another complication of tourniquet use, rupture of the long tendon of the biceps brachii muscle. Some underlying pathologic or degenerative condition usually exists before rupture can occur. Both rheumatoid arthritis and local corticosteroid injections into the long tendon of the biceps probably accounted for weakening the tensile strength of the tendon and subsequent rupture in the case described.

  8. Systematics of injuries of the rotator cuff and biceps tendon

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Pones, M.; Breitenseher, J.B.

    2015-01-01

    Injuries of the rotator cuff and the biceps tendon demonstrate different patterns, which can be recognized clinically and radiologically. These patterns are impingement syndrome with additional trauma, isolated trauma of the rotator cuff and shoulder dislocation causing rotator cuff tears. Furthermore, it is clinically crucial to evaluate the extent of a rotator cuff injury. Magnetic resonance imaging (MRI) is the modality of choice to differentiate these patterns. (orig.) [de

  9. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  10. Visualization of the extra-articular portion of the long head of the biceps tendon during intra-articular shoulder arthroscopy.

    Science.gov (United States)

    Festa, Anthony; Allert, Jesse; Issa, Kimona; Tasto, James P; Myer, Jonathan J

    2014-11-01

    To quantify the amount of the extra-articular long head of the biceps tendon (LHBT) seen during intra-articular shoulder arthroscopy by pulling the tendon into the joint with a probe through an anterior portal while viewing through a standard posterior portal. Intra-articular shoulder arthroscopy was performed on 10 forequarter cadaveric specimens. The extra-articular portion of the LHBT was evaluated by pulling the tendon into the joint with an arthroscopic probe inserted through an anterior portal. The tendon was marked at the pulley insertion on the humerus with a vascular clip before and after the tendon was pulled into the joint. An open deltopectoral approach was performed, and the amount of extra-articular tendon visualized was calculated as an absolute amount and in relation to nearby anatomic structures. An additional 1.9 cm (range, 1.4 to 2.6 cm) of extra-articular LHBT was viewed by pulling the tendon into the joint with an arthroscopic probe through an anterior portal during shoulder arthroscopy. This represented 30.8% of the extra-articular portion of the tendon, 47.7% of tendon in the bicipital groove, and 76.3% of the tendon that lies under the area from the pulley insertion to the distal edge of the transverse humeral ligament. During intra-articular shoulder arthroscopy, the extra-articular portion of the LHBT is incompletely visualized by pulling the tendon into the joint with a probe placed through an anterior portal while viewing through a standard posterior portal. An additional extra-articular portion of the LHBT may be viewed by pulling the tendon into the joint with an arthroscopic probe during shoulder arthroscopy. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits.

    Science.gov (United States)

    Al-Qattan, Mohammad M; Mawlana, Ola Helmi; Mohammed Ahmed, Raeesa Abdel-Twab; Hawary, Khalid

    2016-05-01

    To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. An experimental study. King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings.

  12. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits

    International Nuclear Information System (INIS)

    Al-Qattan, M. M.; Hawary, K.; Mawlana, O. H.; Ahmed, R. A. M.

    2016-01-01

    Objective: To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. Study Design: An experimental study. Place and Duration of Study: King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Methodology: Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Result: Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Conclusion: Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings. (author)

  13. Association between distal ulnar morphology and extensor carpi ulnaris tendon pathology

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Kattapuram, Susan V.; Torriani, Martin

    2014-01-01

    The purpose of this study was to evaluate the association between distal ulnar morphology and extensor carpi ulnaris (ECU) tendon pathology. We retrospectively reviewed 71 adult wrist MRI studies with ECU tendon pathology (tenosynovitis, tendinopathy, or tear), and/or ECU subluxation. Subjects did not have a history of trauma, surgery, infection, or inflammatory arthritis. MRI studies from 46 subjects without ECU tendon pathology or subluxation were used as controls. The following morphological parameters of the distal ulna were measured independently by two readers: ulnar variance relative to radius, ulnar styloid process length, ECU groove depth and length. Subjects and controls were compared using Student's t test. Inter-observer agreement (ICC) was calculated. There was a significant correlation between negative ulnar variance and ECU tendon pathology (reader 1 [R1], P = 0.01; reader 2 [R2], P 0.64 for all parameters. Distal ulnar morphology may be associated with ECU tendon abnormalities. (orig.)

  14. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  15. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    International Nuclear Information System (INIS)

    De Maeseneer, Michel; Brigido, Monica Kalume; Antic, Marijana; Lenchik, Leon; Milants, Annemieke; Vereecke, Evie; Jager, Tjeerd; Shahabpour, Maryam

    2015-01-01

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  16. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    De Maeseneer, Michel, E-mail: Michel.demaeseneer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Brigido, Monica Kalume, E-mail: Mbrigido@med.umich.edu [Department of Radiology, University of Michigan, Ann Arbor, MI (United States); Antic, Marijana, E-mail: Misscroa@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Lenchik, Leon, E-mail: Llenchik@wakehealth.edu [Department of Radiology, Wake Forest University, Winston-Salem, NC (United States); Milants, Annemieke, E-mail: Annemieke.Milants@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Vereecke, Evie, E-mail: Evie.Vereecke@kuleuven-kulak.be [Department of Anatomy, KULAK, Katholieke Universiteit Leuven, Campus Kortrijk, Kortrijk (Belgium); Jager, Tjeerd [Aalsters Stedelijk Ziekenhuis, Aalst (Belgium); Shahabpour, Maryam, E-mail: Maryam.Shahabpour@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium)

    2015-04-15

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  17. Highly Unusual Tendon Abnormality: Spontaneous Rupture of the Distal Iliopsoas Tendon

    Directory of Open Access Journals (Sweden)

    Gokcen Coban

    2014-06-01

    Full Text Available Iliopsoas tendon injuries are not common and usually occur due to avulsion of the iliopsoas tendon with detachment of the lesser trochanter, secondary to an athletic injury or trauma. In the absence of a trauma, avulsion of the lesser trochanter in an adult is regarded as a sign of metastatic disease until proven otherwise. Complete iliopsoas tendon tears have thus far only been described in elderly women, and without trauma or an underlying systemic disease, a hormonal basis may be a reason for the gender differences. In this article, we present an 87-year-old woman with spontaneous rupture of the left distal iliopsoas tendon unassociated with fracture of the lesser trochanter and in the absence of a recent trauma history. This elderly patient presented with acute groin pain and normal plain radiographs. Magnetic resonance imaging must be kept in mind as a modality of choice for identifying iliopsoas tendon abnormalities.

  18. Distal insertions of the semimembranosus tendon: MR imaging with anatomic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Maeseneer, Michel de [Universitair Ziekenhuis Brussel, Department of Radiology, Jette, Brussels (Belgium); Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium); Shahabpour, Maryam; Milants, Annemieke; Ridder, Filip de; Mey, Johan de [Universitair Ziekenhuis Brussel, Department of Radiology, Jette, Brussels (Belgium); Lenchik, Leon [Wake Forest University, Department of Radiology, Winston-Salem, NC (United States); Cattrysse, Erik [Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium)

    2014-06-15

    The purpose of this study is to investigate the distal insertions of the semimembranosus tendon with MR imaging, correlated with findings in cadavers. Four fresh cadaveric specimens were studied with 3-T MR imaging. Sequences included proton density (PD) sequences (TE, 13; TR, 4957; FOV, 170 x 170; matrix, 424 x 413; NA, 2; slice thickness, 2.5 mm) in the axial, coronal, and sagittal planes and 3D fast field echo (FFE) sequences (TR 9.4; TE 6.9; FOV, 159 x 105; matrix, 200 x 211; NA, 2; slice thickness, 0.57 mm). One specimen was dissected and three specimens were sectioned with a bandsaw in the axial, coronal, and sagittal plane. The sections were photographed and correlated with MR images. To standardize the analysis, the semimembranosus muscle and tendon were assessed at seven levels for the axial sections, and at three levels for the coronal and sagittal sections. Anatomic dissection revealed six insertions of the distal semimembranosus tendon: direct arm, anterior arm, posterior oblique ligament extension, oblique popliteal ligament extension, distal tibial expansion (popliteus aponeurosis), and meniscal arm. Axial MR images showed five of six insertions: direct arm, anterior arm, oblique popliteal ligament extension, posterior oblique ligament extension, and distal tibial expansion. Sagittal MR images showed four of six insertions: direct arm, anterior arm, oblique popliteal ligament arm, and distal tibial expansion. Sagittal MR images were ideal for showing the direct arm insertion, but were less optimal than the axial images for showing the other insertions. The anterior arm was seen but volume averaging was present with the gracilis tendon. Coronal MR images optimally revealed the anterior arm, although magic angle artifact was present at its posterior aspect. The common semimembranosus tendon and meniscal arm were also well depicted. The division in anterior arm, direct arm, and oblique popliteal ligament arm was poorly seen on coronal images due to

  19. Association between distal ulnar morphology and extensor carpi ulnaris tendon pathology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Kattapuram, Susan V.; Torriani, Martin [General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Massachusetts, Boston, MA (United States)

    2014-06-15

    The purpose of this study was to evaluate the association between distal ulnar morphology and extensor carpi ulnaris (ECU) tendon pathology. We retrospectively reviewed 71 adult wrist MRI studies with ECU tendon pathology (tenosynovitis, tendinopathy, or tear), and/or ECU subluxation. Subjects did not have a history of trauma, surgery, infection, or inflammatory arthritis. MRI studies from 46 subjects without ECU tendon pathology or subluxation were used as controls. The following morphological parameters of the distal ulna were measured independently by two readers: ulnar variance relative to radius, ulnar styloid process length, ECU groove depth and length. Subjects and controls were compared using Student's t test. Inter-observer agreement (ICC) was calculated. There was a significant correlation between negative ulnar variance and ECU tendon pathology (reader 1 [R1], P = 0.01; reader 2 [R2], P < 0.0001; R1 and R2 averaged data, P < 0.0001) and ECU tendon subluxation (P = 0.001; P = 0.0001; P < 0.0001). In subjects with ECU tendon subluxation there was also a trend toward a shorter length (P = 0.3; P <0.0001; P = 0.001) and a shallower ECU groove (P = 0.01; P = 0.03; P = 0.01; R1 and R2 averaged data with Bonferroni correction, P = 0.08). ECU groove depth (P = 0.6; P = 0.8; P = 0.9) and groove length (P = 0.1; P = 0.4; P = 0.7) showed no significant correlation with ECU tendon pathology, and length of the ulnar styloid process showed no significant correlation with ECU tendon pathology (P = 0.2; P = 0.3; P = 0.2) or subluxation (P = 0.4; P = 0.5; P = 0.5). Inter-observer agreement (ICC) was >0.64 for all parameters. Distal ulnar morphology may be associated with ECU tendon abnormalities. (orig.)

  20. Abnormal origins of the long head of the biceps tendon can lead to rotator cuff pathology: a report of two cases.

    Science.gov (United States)

    Zhang, Alan L; Gates, Cameron H; Link, Thomas M; Ma, C Benjamin

    2014-11-01

    Previous case reports have highlighted various anomalous origins of the long head of the biceps tendon (LHBT) that do not originate from the superior glenoid labrum or supraglenoid tubercle. Yet, these cases were all reported as incidental findings and were not thought to cause any significant shoulder pathology. We present the magnetic resonance (MR) imaging and clinical treatment of two cases where aberrant intra-articular origins of the long head of the biceps tendon from the anterior edge of the supraspinatus tendon may have contributed to symptomatic rotator cuff pathology. Arthroscopy confirmed MR findings of partial articular-sided supraspinatus lesions in close proximity to the anomalous origins and treatment with tenodesis of the LHBT successfully relieved symptoms. Although rare occurrences with subtle and potentially misleading imaging findings, it is important to be aware of aberrant origins of the LHBT that may contribute to concomitant rotator cuff pathology.

  1. Evaluation of the clinical-functional results from repairing extensive rotator cuff injury with inclusion of the tendon of the long head of the biceps

    Directory of Open Access Journals (Sweden)

    Roberto Yukio Ikemoto

    2013-04-01

    Full Text Available OBJECTIVES: To assess the outcomes of the arthroscopic margin convergence of the posterior cuff to the biceps tendon. METHODS: From October 2003 to December 2007, 20 patients with massive rotator cuff tear which include the rotator interval were treated with arthroscopic margin convergence of the posterior cuff to biceps tendon. Sixteen patients were female and four were male. The mean age was 58.95 years old. The dominant side was affected in 16 cases (80%. The outcomes were analysed according to the UCLA Score with a minimum follow-up period of two years. RESULTS: The UCLA score improved, on average, 14 points (p < 0.001. Six patients had excellent results; nine good; three fair and two poor results. The mean improvement of forward flexion was 33º (p < 0.001, 3º of external rotation (p < 0.396 and two vertebral levels for internal rotation (p < 0.025. CONCLUSION: The arthroscopic margin convergence of the posterior cuff to the biceps tendon leads to satisfactory results.

  2. Spontaneous rupture of the distal iliopsoas tendon: clinical and imaging findings, with anatomic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E.; Vande Berg, Bruno C.; Malghem, Jacques [Universite Catholique de Louvain, Department of Radiology and Medical Imaging, Saint Luc University Hospital, Brussels (Belgium); Demondion, Xavier [Centre Hospitalier Universitaire de Lille, Department of Bone Radiology and Laboratory of Anatomy, Lille (France); Leemrijse, Thibaut [Universite Catholique de Louvain, Department of Orthopedic Surgery, Saint Luc University Hospital, Brussels (Belgium); Devogelaer, Jean-Pierre [Universite Catholique de Louvain, Department of Rheumatology, Saint Luc University Hospital, Brussels (Belgium)

    2005-11-01

    We report the clinical and imaging findings in two elderly female patients with spontaneous rupture of the distal iliopsoas tendon from the lesser trochanter of the femur. We emphasize the key contribution of magnetic resonance (MR) imaging to this diagnosis and provide an anatomic correlation. Spontaneous rupture of the distal iliopsoas tendon should be kept in mind in the differential diagnosis of acute groin pain in the elderly. MR imaging enables positive diagnosis, by showing mass effect on the anterior aspect of the hip joint, proximal muscle thickening, and abnormal signal intensity, and by demonstrating interruption of the psoas tendon, whereas the distal insertion of the lateral portion of the iliacus muscle remains muscular and is preserved. (orig.)

  3. Tendon patch grafting using the long head of the biceps for irreparable massive rotator cuff tears

    International Nuclear Information System (INIS)

    Sano, Hirotaka; Itoi, Eiji; Mineta, Mitsuyoshi; Kita, Atsushi

    2010-01-01

    Surgical treatment of massive rotator cuff tears is challenging for shoulder surgeons. The purpose of this study was to investigate both clinical outcomes and cuff integrity after tendon patch grafting using the long head of the biceps (LHB) tendon for irreparable massive rotator cuff tears. A short deltoid splitting approach was used to expose the torn cuff tendon stump. After tenodesis of the LHB tendon, its intraarticular portion was resected. If the size of the harvested tendon was smaller than that of the cuff defect, it was split into two layers. Then, the LHB tendon was sutured to the remnant cuff tendons and fixed to the footprint using the transosseous suture technique. A total of 14 patients (12 men, 2 women; average age 64 years) underwent this procedure. The average postoperative follow-up period was 28 months (range 12-51 months). Active elevation angle of the shoulder as well as the Japanese Orthopaedic Association (JOA) score were assessed before surgery and at the time of follow-up. Postoperative cuff integrity was assessed using T2-weighted magnetic resonance imaging (MRI). All cuff defects were successfully closed with this technique. Average active elevation angle improved from 69deg to 149deg. Total JOA score also improved from 54.7 points to 83.1 points. Thirteen shoulders showed no re-tearing on T2-weighted MRI; a minor discontinuity of the repaired cuff tendon was observed in the other shoulder. The LHB tendon is available in case tenodesis or tenotomy is needed. The resected tendon may be used as a graft for rotator cuff repair without any additional skin incision, which could reduce both the surgical invasion and the risk of infection. The LHB tendon patch grafting may be one of the useful options for surgical treatment of irreparable massive rotator cuff tears. (author)

  4. Extraarticular variants of the long head of the biceps brachii: a reminder of embryology.

    Science.gov (United States)

    Audenaert, Emmanuel A; Barbaix, Erik J; Van Hoonacker, Petrus; Berghs, Bart M

    2008-01-01

    Developmental anomalies of the long head of the biceps tendon are rare and have been described in the literature mainly dealing with anatomy and embryology. Because most basic embryologic research on this topic was conducted before 1966, a literature search was performed from archived anatomy textbooks and manuscript references. These data were compared with the scarce case descriptions of developmental anomalies of the long head of the biceps tendon. An additional case illustration from our own experience was provided. From the literature, it appears that during the embryologic phase of development, a staged migration of the long head of the biceps tendon occurs from a position between the fibrous capsule and synovial layer to an intraarticular position. Recent anatomic and arthroscopic case reports have shown that interruption of this migration can occur in any of these stages. Given the recent increase in arthroscopic shoulder surgery, anomalies of the long head of the biceps tendon will be encountered more frequently. Knowledge of their existence and origin can help in evaluating unexpected anatomic variations or the absence of the biceps tendon in preoperative medical imaging or during an arthroscopic procedure.

  5. Achilles Tendonitis

    Science.gov (United States)

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  6. Measurement of the tendon of the biceps brachii after tenotomy: study on cadavers

    Directory of Open Access Journals (Sweden)

    Anderson Cunha Machado

    2015-08-01

    Full Text Available ABSTRACTOBJECTIVE: To evaluate the influence of elbow and forearm range of motion on the distal excursion of the long head of the biceps (LHB. METHODS: The distal excursion of the LHB after tenotomy of the shoulders of eight cadavers was ascertained by measuring the distance between a point marked out on the LHB, 3 cm from the anterolateral border of the acromion, and its position at different degrees of elbow flexion, using a digital pachymeter. The measurements at elbow flexion of 135°, 90°, 45° and 0° were noted: these angles were established using a goniometer. The measurements were made with the forearm in neutral, supination and pronation positions. RESULTS: Differences between the mean measurements of the distal excursion of the LHB (total sample were observed between the degrees of elbow flexion ( p< 0.01. However, no statistical differences were observed between the different forearm positions, between the sides, genders and ages of the cadavers studied. CONCLUSION: Progressive extension of the elbow caused progressive distal excursion of the LHB, but without interference in the forearm position, gender, side or age of the cadavers studied.

  7. Biceps tendinitis caused by an osteochondroma in the bicipital groove: a rare cause of shoulder pain in a baseball player.

    Science.gov (United States)

    Onga, Takafumi; Yamamoto, Tetsuji; Akisue, Toshihiro; Marui, Takashi; Kurosaka, Masahiro

    2005-02-01

    Tendinitis of the long head of the biceps brachii muscle is commonly seen in athletes who do repetitive overhead motions. Common causes of biceps tendinitis include impingement syndrome, subluxation of the biceps tendon, and attrition tendinitis, whereas biceps tendinitis secondary to a bone neoplasm is rare. A case of biceps tendinitis caused by an osteochondroma arising in the left humeral bicipital groove in a 25-year-old male baseball player is reported. The tumor was hook-shaped, originated from the inferomedial portion of the humeral lesser tubercle, and surrounded the biceps tendon. Symptoms of increasing pain and inability to throw resulted from direct irritation of the biceps tendon by the tumor. Total excision of the tumor relieved the symptoms within 3 weeks. To our knowledge, there have been no reported cases in the English-language literature of biceps tendinitis caused by an osteochondroma.

  8. ARTHROSCOPIC CORRECTION OF THE INJURIES OF THE COMPLEX «TENDON OF THE BICEPS LONG HEAD - THE ARTICULAR LIP» IN TREATMENT OF PATIENTS WITH FULL-LAYER RUPTURES OF THE ROTATOR CUFF

    Directory of Open Access Journals (Sweden)

    S. Y. Dokolin

    2013-01-01

    Full Text Available Damage of the long head of the biceps at the place of attachment to the articular tubercle supraglenoidal lip of shoulder, to the entrance and throughout intertubercle furrows are common causes of pain and dysfunction of the shoulder joint. At the same clinical manifestations of the morphology of such lesions may be different. The current literature discusses various options of surgical correction of the biceps injury. Variety of methods of surgical treatment and the lack of consensus in support of their application in different patients in different types of injuries were the basis for the present study. A prospective analysis of the functional results of surgical treatment of the 34 - year’s patients with associated rotator cuff (SSP+ISP+SSC+ and the tendon of the biceps muscle in age from 34 to 75 years. Options for surgical correction of the damaged part of the biceps were: biceps tenotomy, biceps tenotomy with intraarticular tenodez of the shoulder to the head before entering intertubercle furrow, biceps tenotomy and extraarticular subpectorialtenodez to the proximal humerus is intertubercle interferrent screw groove, as well as its attachment to the tendon suture large pectoral muscle. Choice of surgical approach depended on the patient's age, level of daily physical activity, morphology and localization of lesions. The best results were obtained when the extra-articular subpectorialtenodez of long head of the biceps to the proximal humerus interferrent screw and suture fixation to the pectoralis major muscle, the average follow-up was 16,6 ± 4,7 months.

  9. Biceps Autograft Augmentation for Rotator Cuff Repair : A Systematic Review

    NARCIS (Netherlands)

    Veen, Egbert J D; Stevens, Martin; Diercks, Ronald L

    Purpose: To improve surgical outcomes in patients with massive cuff defects, different techniques and augmentations are proposed. The biceps tendon is easily available as an autograft. Our aim was to conduct a qualitative systematic review of various methods and surgical techniques that use a biceps

  10. Can osseous landmarks in the distal medial humerus be used to identify the attachment sites of ligaments and tendons: paleopathologic-anatomic imaging study in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M. [Veterans Administration Medical Center, Department of Radiology, San Diego, CA (United States); Institut fuer Diagnostische Radiologie, Uniklinik Balgrist, Zurich (Switzerland); Zoner, Cristiane S.; Cardoso, Fabiano; Gheno, Ramon; Nico, Marcelo A.C.; Trudell, Debra J.; Resnick, Donald [Veterans Administration Medical Center, Department of Radiology, San Diego, CA (United States); Randall, Tori D. [San Diego Museum of Man, Physical Anthropology, San Diego, CA (United States)

    2010-09-15

    To describe osseous landmarks that allow identification of the attachments of the ligaments and tendons in the distal medial aspect of the humerus. Reliable osseous landmarks in the distal medial aspect of the humerus were identified in 34 well-preserved specimens from a paleopathologic collection. These osseous landmarks were then sought in magnetic resonance (MR) images of ten cadaveric elbow specimens so that the ease of their visualization and optimal imaging plane could be assessed. To assign these osseous landmarks to specific attachments of the tendons and ligaments in the distal medial humerus, we cut the specimens in slices and photographed and examined them. Subsequently, the prevalence of these osseous landmarks as well as the attachment sites of the tendons and ligaments in this location was determined. We determined ten reliable osseous landmarks in the distal medial aspect of the humerus, their prevalence and ease of identification, and their relationship to the attachments of the tendons and ligaments at the medial distal humerus. It is possible to use osseous landmarks at the distal medial humerus to facilitate identification of the different attachments of tendons and ligaments when MR images of the elbow are assessed. (orig.)

  11. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    Science.gov (United States)

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  12. Rare muscular variations identified in a single cadaveric upper limb: a four-headed biceps brachii and muscular elevator of the latissimus dorsi tendon.

    Science.gov (United States)

    Moore, Colin W; Rice, Charles L

    2018-03-01

    Supernumerary or accessory heads of the biceps brachii are persistent muscular structures which can vary in number and location in the arm. Variations in other arm muscles, such as the coracobrachialis, can accompany supernumerary biceps brachii musculature in the upper limb. In this case report, we describe two rare muscular variants in a single adult male: a four-headed biceps brachii and the muscular elevator of the latissimus dorsi tendon. Additionally, accessory muscles of the brachialis and flexor digiti minimi brevis were identified in the upper limb. To our knowledge, the muscular variants identified here are considered rare, and their co-occurrence in a single upper limb has not been described previously. Also, a four-headed biceps brachii consisting of both the infero-medial and infero-lateral humeral heads has not been described previously to our knowledge. We postulate that the simultaneous appearance of several muscular variations may indicate a signaling disruption in embryogenesis during muscle patterning of the ventral limb bud. Knowledge of variant musculature in the arm is important for surgeons and clinicians as these muscles and their aberrant innervation patterns can complicate surgical procedures and may compress arteries and nerves producing upper limb pain and paresthesia. The clinical, functional and embryological implications of the upper limb variants are discussed.

  13. Primary tendinitis of the long head of the biceps.

    Science.gov (United States)

    Post, M; Benca, P

    1989-09-01

    Seventeen patients with chronic painful shoulders who showed evidence of isolated bicipital tendinitis involving only the extracapsular, intertubercular portion of the long head of the biceps were chosen for surgical treatment when conservative treatment failed. The patients were thought to have primary bicipital tendinitis. The latter condition is secondary to other shoulder pathologies. Thirteen patients had tenodeses and four patients had transfer of the long head of the biceps to the origin of the conjoined tendon. Overall, excellent and good results were noted in 94% of both groups of patients when the long head of the biceps was tenodesed or transferred. Whether or not the long head of the biceps is a significant depressor of the humeral head requires further investigation.

  14. The fibrocartilaginous sesamoid: a cause of size and signal variation in the normal distal posterior tibial tendon

    Energy Technology Data Exchange (ETDEWEB)

    Delfaut, E.M.; Bieganski, A.; Cotten, A. [Department of Skeletal Radiology, Roger Salengro Hospital, CHRU of Lille, Bd du Professeur Jules Leclercq, 59037, Lille Cedex (France); Demondion, X. [Department of Skeletal Radiology, Roger Salengro Hospital, CHRU of Lille, Bd du Professeur Jules Leclercq, 59037, Lille Cedex (France); Department of Anatomy, Faculty of Medicine, Place de Verdun, 59037, Lille Cedex (France); Cotten, H. [Pathology Laboratory, 128 Bd de la Liberte, 59000, Lille Cedex (France); Mestdagh, H. [Department of Orthopaedic Surgery, Roger Salengro Hospital, CHRU of Lille, Bd du Professeur Jules Leclercq, 59037, Lille Cedex (France)

    2003-12-01

    The aim of this study was to investigate the presence of fibrocartilage within the distal posterior tibial tendon (PTT) before its division correlating with size and signal variation on MR images through a radio-anatomic and pathologic study. Eight fresh cadaveric feet underwent MR imaging were cut into 4-mm slices in the axial plane. The PTT specimens were harvested at the tendon distal portion before its division and sent to pathology. Thirty-three asymptomatic subjects underwent axial double-echo turbo-spin-echo MR imaging. Proximal and distal PTT signal and diameter were evaluated. In cadavers, every PTT flared distally. Intratendinous fibrocartilage and ossified sesamoid were found in, respectively, 87.5 and 12.5% of the cases. Distal PTT flaring was demonstrated in 100% of the asymptomatic subjects (mean diameter 8 mm). An intratendinous high signal intensity on proton-density-weighted images and sesamoid bone were evidenced in, respectively, 36 and 33% of the cases. Proximally, PTT presented a 4-mm mean diameter and was hypointense in 100% of the cases. Only one accessory navicular bone was detected. Laterally off-centered increased intratendinous signal intensity as well as PTT distal widening with otherwise normal MR imaging features are related to an intratendinous fibrocartilage. (orig.)

  15. Increased muscle belly and tendon stiffness in patients with Parkinson's disease, as measured by myotonometry.

    Science.gov (United States)

    Marusiak, Jarosław; Jaskólska, Anna; Budrewicz, Sławomir; Koszewicz, Magdalena; Jaskólski, Artur

    2011-09-01

    Based on Davis's law, greater tonus of the muscle belly in individuals with Parkinson's disease can create greater tension in the tendon, leading to structural adjustment and an increase in tendon stiffness. Our study aimed to separately assess passive stiffness in the muscle belly and tendon in medicated patients with Parkinson's disease, using myotonometry. We tested 12 patients with Parkinson's disease and 12 healthy matched controls. Passive stiffness of muscle belly and tendon was estimated by myotonometry, electromyography, and mechanomyography in relaxed biceps and triceps brachii muscles. Compared with controls, patients with Parkinson's disease had higher stiffness in the muscle belly and tendon of the biceps brachii and in the tendon of the triceps brachii. In patients with Parkinson's disease, there was a positive correlation between muscle belly stiffness and parkinsonian rigidity in the biceps brachii. Patients with Parkinson's disease have higher passive stiffness of the muscle belly and tendon than healthy matched controls. Copyright © 2011 Movement Disorder Society.

  16. Vascular abnormalities of the distal deep digital flexor tendon in 8 draught horses identified on histological examination.

    Science.gov (United States)

    Crişan, Melania Ioana; Damian, Aurel; Gal, Adrian; Miclăuş, Viorel; Cernea, Cristina L; Denoix, Jean-Marie

    2013-08-01

    The purpose of this study was to provide a detailed description of the vascular changes in the distal part of deep digital flexor tendon (DDFT). Eight isolated forelimbs were collected from 8 horses with DDF tendinopathy diagnosed post-mortem by ultrasound and gross anatomopathological examination. The samples were fixed in 10% neutral buffered formalin, softened in 4% phenol and dehydrated with ethylic alcohol. Goldner's Trichrome staining method was used. The histopathological examination revealed vascular proliferation associated with structural disorders of blood vessels. Angiogenesis, fibroplasia and consecutive hypertrophy of the vascular wall with or without vascular occlusion were the most common findings. Other histopathological findings were: endothelial cell edema, progressive metaplasia from squamous to cubic cells, vascular wall hyalinization, endothelial cells apoptosis/necrosis and endothelial desquamation. These results demonstrated damage of the distal deep digital flexor tendon vasculature which may progressively alter the structural integrity of the tendon and contribute to degenerative lesions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Mapping the Articular Contact Area of the Long Head of the Biceps Tendon on the Humeral Head

    Directory of Open Access Journals (Sweden)

    Brent J. Morris

    2014-01-01

    Full Text Available The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P=0.002 with a median ratio of 41% (36%, 47.5%. Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho=1, P=0.017 as were ratios of abduction area to full articular surface area (rho= 0.97, P=0.005. The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  18. Does Additional Biceps Augmentation Improve Rotator Cuff Healing and Clinical Outcomes in Anterior L-Shaped Rotator Cuff Tears? Clinical Comparisons With Arthroscopic Partial Repair.

    Science.gov (United States)

    Jeon, Yoon Sang; Lee, Juyeob; Kim, Rag Gyu; Ko, Young-Won; Shin, Sang-Jin

    2017-11-01

    The repair of anterior L-shaped tears is usually difficult because of the lack of anterior rotator cuff tendon to cover the footprint. The biceps tendon is usually exposed from the retracted anterolateral corner of the torn tendon and can be easily used to augment rotator cuff repair. Hypothesis/Purpose: This study compared the clinical outcomes of the biceps augmentation technique with those of partial tendon repair for the arthroscopic treatment of large anterior L-shaped rotator cuff tears to evaluate the role of additional biceps augmentation in tendon healing. We hypothesized that the biceps augmentation technique would lead to a lower rotator cuff tendon retear rate and provide satisfactory functional outcomes. Cohort study; Level of evidence, 3. This study included 64 patients with anterior L-shaped rotator cuff tears who underwent arthroscopic repair. Patients were divided into 2 groups: group A (31 patients) underwent repair of an anterior L-shaped tear combined with biceps augmentation, and group B (33 patients) had a partially repaired tendon whose footprint was exposed after repair without undue tension on the retracted tendon. Clinical evaluations were performed using the American Shoulder and Elbow Surgeons (ASES) score, Constant score, muscle strength, visual analog scale for pain, and patient satisfaction. Magnetic resonance imaging (MRI) was performed for tendon integrity at 6 months postoperatively. The mean period of follow-up was 29.1 ± 3.5 months (range, 24-40 months). The mean ASES and Constant scores significantly improved from 52.8 ± 10.6 and 43.2 ± 9.9 preoperatively to 88.2 ± 6.9 and 86.8 ± 6.2 at final follow-up in group A ( P rotation [ER]: 57.5 ± 9.9 to 86.8 ± 9.3; internal rotation [IR]: 68.1 ± 10.8 to 88.1 ± 8.4; P rotator cuff tendon on postoperative MRI. The retear rate between the 2 groups showed no significant difference ( P = .552). Regarding clinical outcomes, both groups had no significant difference in the ASES score

  19. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  20. Systematics of injuries of the rotator cuff and biceps tendon; Systematik der Verletzungen von Rotatorenmanschette und Bizepssehne

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Landesklinikum Horn, Institut fuer Radiologie und interventionelle Radiologie, Horn (Austria); Pones, M.; Breitenseher, J.B. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria)

    2015-03-01

    Injuries of the rotator cuff and the biceps tendon demonstrate different patterns, which can be recognized clinically and radiologically. These patterns are impingement syndrome with additional trauma, isolated trauma of the rotator cuff and shoulder dislocation causing rotator cuff tears. Furthermore, it is clinically crucial to evaluate the extent of a rotator cuff injury. Magnetic resonance imaging (MRI) is the modality of choice to differentiate these patterns. (orig.) [German] Bei der Verletzung von Rotatorenmanschette und Bizepssehne koennen verschiedene Muster klinisch und radiologisch erkannt werden. Diese Muster sind das Impingementsyndrom mit einem zusaetzlichen Trauma, das isolierte Trauma und die Verletzung der Rotatorenmanschette im Rahmen einer Schulterluxation. Darueber hinaus ist die Beurteilung des Ausmasses einer Verletzung von zentraler klinischer Relevanz. Die MRT kann die Differenzierung dieser Muster bestmoeglich durchfuehren. (orig.)

  1. Direct lentiviral-cyclooxygenase 2 application to the tendon-bone interface promotes osteointegration and enhances return of the pull-out tensile strength of the tendon graft in a rat model of biceps tenodesis.

    Directory of Open Access Journals (Sweden)

    Charles H Rundle

    Full Text Available This study sought to determine if direct application of the lentiviral (LV-cyclooxygenase 2 (COX2 vector to the tendon-bone interface would promote osteointegration of the tendon graft in a rat model of biceps tenodesis. The LV-COX2 gene transfer strategy was chosen for investigation because a similar COX2 gene transfer strategy promoted bony bridging of the fracture gap during bone repair, which involves similar histologic transitions that occur in osteointegration. Briefly, a 1.14-mm diameter tunnel was drilled in the mid-groove of the humerus of adult Fischer 344 rats. The LV-COX2 or βgal control vector was applied directly into the bone tunnel and onto the end of the tendon graft, which was then pulled into the bone tunnel. A poly-L-lactide pin was press-fitted into the tunnel as interference fixation. Animals were sacrificed at 3, 5, or 8 weeks for histology analysis of osteointegration. The LV-COX2 gene transfer strategy enhanced neo-chondrogenesis at the tendon-bone interface but with only marginal effect on de novo bone formation. The tendon-bone interface of the LV-COX2-treated tenodesis showed the well-defined tendon-to-fibrocartilage-to-bone histologic transitions that are indicative of osteointegration of the tendon graft. The LV-COX2 in vivo gene transfer strategy also significantly enhanced angiogenesis at the tendon-bone interface. To determine if the increased osteointegration was translated into an improved pull-out mechanical strength property, the pull-out tensile strength of the LV-COX2-treated tendon grafts was determined with a pull-out mechanical testing assay. The LV-COX2 strategy yielded a significant improvement in the return of the pull-out strength of the tendon graft after 8 weeks. In conclusion, the COX2-based in vivo gene transfer strategy enhanced angiogenesis, osteointegration and improved return of the pull-out strength of the tendon graft. Thus, this strategy has great potential to be developed into an

  2. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon [University of Ulsan, College of Medicine, Department of Radiology, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of); Lee, Man Ho [Andong Medical Center, Department of Radiology, Andong-si, Gyeongsangbuk-do (Korea, Republic of); Lee, Ki Won [University of Ulsan, College of Medicine, Department of Orthopedic Surgery, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of)

    2016-12-15

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  3. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    International Nuclear Information System (INIS)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Man Ho; Lee, Ki Won

    2016-01-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  4. The incidence of pathologic changes of the long head of the biceps tendon.

    Science.gov (United States)

    Murthi, A M; Vosburgh, C L; Neviaser, T J

    2000-01-01

    The incidence of primary and secondary bicipital tendinitis remains unknown. In our prospective study, 200 consecutive shoulders underwent arthroscopic subacromial decompression for impingement syndrome. A biceps tenodesis was performed in 80 shoulders (40%) featuring macroscopic degeneration of the long head of the biceps; rotator cuff tears were apparent in 91% of these shoulders, the mean patient age being 55 years. In each of 120 shoulders (60%), an extraarticular tenosynovectomy was performed, and histopathologic studies revealed chronic inflammation in 63% and fibrotic degeneration in 13% of the specimens; rotator cuff tears were evident in 70% (23% full thickness) of these cases, the mean patient age being 47 years. In addition, when glenohumeral arthritis was present, it was uniformly associated with pathologic biceps tenosynovium. In summary, the high incidence of chronic inflammation of the long head of the biceps in shoulders with benign-appearing intraarticular portions viewed arthroscopically is significant, and long head of the biceps disease should also be considered in patients with painful rotator cuff disease and arthritic shoulder conditions.

  5. MR arthrographic findings in tenosynovitis of the long bicipital tendon of the shoulder

    International Nuclear Information System (INIS)

    Gueckel, C.; Nidecker, A.

    1998-01-01

    Purpose. To assess the MR arthrographic findings of bicipital tenosynovitis in correlation with arthroscopy. Design and patients. The shoulder MR arthrographies of 500 consecutive patients were retrospectively analyzed for signs of bicipital tenosynovitis and associated pathologies. Forty patients (8%) had MR evidence of bicipital tenosynovitis, but only 17 (3%) with arthroscopic confirmation were included in the study. The MR findings in these patients were compared with those of 10 patients with rotator cuff lesions but arthroscopically normal long biceps tendons. MR arthrography was performed with 10-15 ml of a 250 mmol/l gadoterate meglumine (Gd-DOTA) solution injected under fluoroscopic guidance, and transaxial, oblique coronal and sagittal MR sequences were obtained. Results. All 17 patients showed one or more abnormal findings: signal increase in the tendon with or without fusiform distension was seen in 12, surface irregularities in six, adhesions in 11 and noncommunicating effusions of the tendon sheath in six. Associated abnormalities of the rotator cuff were present in 16 while the seventeenth patient had glenohumeral synovitis without rotator cuff pathology. MR arthrograms correlated with arthroscopic findings in the joint but comparison was not possible in the intertubercular groove portion of the biceps tendon. None of the 10 patients with an arthroscopically normal biceps tendon showed any of the MR findings of bicipital tenosynovitis. Conclusion. Bicipital tenosynovitis is detectable by MR arthrography. In most cases it is an associated finding of rotator cuff abnormalities and likely to have a similar etiology. When lesions of the anterior rotator cuff are recognized, the biceps tendon should be scrutinized for inflammatory changes. (orig.)

  6. Instability of the long head of the biceps tendon in patients with rotator cuff tear: evaluation on magnetic resonance arthrography of the shoulder with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yusuhn; Lee, Joon Woo; Ahn, Joong Mo; Lee, Eugene; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of)

    2017-10-15

    To evaluate the diagnostic value of MR arthrography (MRA) in diagnosing instability of the LHBT in patients with rotator cuff tendon tear. The MR arthrograms of 101 patients were retrospectively reviewed and correlated with arthroscopic findings as the standard reference. Images were evaluated for (1) the integrity of the LHBT, (2) the position of the LHBT (subluxation/dislocation on axial images, inferior displacement on oblique sagittal image) and (3) the integrity of the biceps pulley (SGHL, supraspinatus and subscapularis tendon adjacent to the rotator interval). The integrity of the LHBT was correctly classified in 74.3% (75/101) and 66.3% (67/101) by readers 1 and 2, respectively. The diagnosis of LHBT instability could be made on axial images with a sensitivity of 82.6% and 73.9% and specificity of 69.9% and 87.7%, whereas the displacement sign on sagittal images had a sensitivity of 73.9% and 78.3% and a specificity of 64.4% and 61.6%, respectively. Assessing the integrity of the SGHL had a sensitivity of 60.9 and 93.3% and a specificity of 70.4 and 75.0%, respectively. By combining the different image findings, the accuracy in assessing LHBT instability was 80.9 and 90.5% with a sensitivity of 60.9 and 86.7% and specificity of 83.1 and 91.8%, respectively. Individual image findings may have a limited role in diagnosing LHBT instability in patients with rotator cuff tendon tear. The accuracy of MRA may be improved by assessing the integrity of the biceps pulley structures along with the position of the LHBT on both axial and sagittal images. (orig.)

  7. MR arthrographic findings in tenosynovitis of the long bicipital tendon of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Gueckel, C. [Department of Radiology, University Hospital of Basel, Petersgraben 4, CH-4031 Basel (Switzerland); Nidecker, A. [MRI Institut Rebgasse, Untere Rebgasse 18, CH-4058 Basel (Switzerland)

    1998-01-01

    Purpose. To assess the MR arthrographic findings of bicipital tenosynovitis in correlation with arthroscopy. Design and patients. The shoulder MR arthrographies of 500 consecutive patients were retrospectively analyzed for signs of bicipital tenosynovitis and associated pathologies. Forty patients (8%) had MR evidence of bicipital tenosynovitis, but only 17 (3%) with arthroscopic confirmation were included in the study. The MR findings in these patients were compared with those of 10 patients with rotator cuff lesions but arthroscopically normal long biceps tendons. MR arthrography was performed with 10-15 ml of a 250 mmol/l gadoterate meglumine (Gd-DOTA) solution injected under fluoroscopic guidance, and transaxial, oblique coronal and sagittal MR sequences were obtained. Results. All 17 patients showed one or more abnormal findings: signal increase in the tendon with or without fusiform distension was seen in 12, surface irregularities in six, adhesions in 11 and noncommunicating effusions of the tendon sheath in six. Associated abnormalities of the rotator cuff were present in 16 while the seventeenth patient had glenohumeral synovitis without rotator cuff pathology. MR arthrograms correlated with arthroscopic findings in the joint but comparison was not possible in the intertubercular groove portion of the biceps tendon. None of the 10 patients with an arthroscopically normal biceps tendon showed any of the MR findings of bicipital tenosynovitis. Conclusion. Bicipital tenosynovitis is detectable by MR arthrography. In most cases it is an associated finding of rotator cuff abnormalities and likely to have a similar etiology. When lesions of the anterior rotator cuff are recognized, the biceps tendon should be scrutinized for inflammatory changes. (orig.) With 4 figs., 4 tabs., 22 refs.

  8. Disorders of the long head of the biceps: tenotomy versus tenodesis.

    Science.gov (United States)

    Ribeiro, Fabiano Rebouças; Ursolino, André Petry Sandoval; Ramos, Vinicius Ferreira Lima; Takesian, Fernando Hovaguim; Tenor Júnior, Antonio Carlos; Costa, Miguel Pereira da

    2017-01-01

    Disorders of the long head of biceps tendon are common in clinical practice. Their causes could be degenerative, inflammatory, instability (subluxation or luxation) or traumatic. They are generally associated to other diseases of the shoulder, mainly rotator cuff injuries. Currently, there is controversy in the literature regarding the indications for surgical treatment and the choice of the best technique for each case, due to the possibility of esthetic deformity, loss of muscle strength, and residual pain. The objective of this study was to identify the indications for surgical treatment, the best surgical technique, and the advantages and disadvantages of each technique described in the orthopedic literature for the treatment of long head of biceps tendon injuries. A revision of the orthopedic medical literature on the following databases: Biblioteca Regional de Medicina (BIREME), Medline, PubMed, Cochrane Library and Google Scholar, comprising articles published in the period from 1991 to 2015.

  9. Bursitis with severe tendom and muscle necrosis on the lateral stifle area in cattle

    International Nuclear Information System (INIS)

    Nuss, K.; Muggli, E.; Hässig, M.; Räber, M.; Sydler, T.; Guscetti, F.

    2011-01-01

    In 21 animals, chronic swelling on the lateral aspect of the stifle also known as perigonitis, stable-syndrome or bursitis bicipitalis femoris were evaluated. Ultrasonography showed increased fluid in the distal subtendinous bursa of the biceps femoris muscle and structural changes in the tendons, muscles, subcutis and fasciae. Soft tissue swelling and an irregular contour of the lateral tibial condyle were typical signs on radiographs. Macroscopic changes were found at the insertion of the biceps femoris muscle, the distal subtendinous bursa of the biceps femoris muscle, the lateral collateral ligament of the stifle, the origin of muscles on the lateral femoral condyle and the lateral tibial condyle. They mainly consisted of tendon and muscle tissue necrosis with granulation tissue. Histology revealed areas of coagulation necrosis in tendons and ligaments, in which occasionally Onchocerca spp. were seen. The severity of lesions correlated well with the clinical signs, which were associated with a poor prognosis in advanced cases

  10. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    Directory of Open Access Journals (Sweden)

    Maria-Elissavet Nikolaidou

    2014-01-01

    Full Text Available Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports.

  11. Synthetic Augmented Suture Anchor Reconstruction for a Complete Traumatic Distal Triceps Tendon Rupture in a Male Professional Bodybuilder with Postoperative Biomechanical Assessment

    Science.gov (United States)

    Nikolaidou, Maria-Elissavet; Banke, Ingo J.; Laios, Thomas; Petsogiannis, Konstantinos; Mourikis, Anastasios

    2014-01-01

    Bodybuilding is a high-risk sport for distal triceps tendon ruptures. Management, especially in high-demanding athletes, is operative with suture anchor refixation technique being frequently used. However, the rate of rerupture is high due to underlying poor tendon quality. Thus, additional augmentation could be useful. This case report presents a reconstruction technique for a complete traumatic distal triceps tendon rupture in a bodybuilder with postoperative biomechanical assessment. A 28-year-old male professional bodybuilder was treated with a synthetic augmented suture anchor reconstruction for a complete triceps tendon rupture of his right dominant elbow. Postoperative biomechanical assessment included isokinetic elbow strength and endurance testing by using multiple angular velocities to simulate the “off-season” and “precompetition” phases of training. Eighteen months postoperatively and after full return to training, the biomechanical assessment indicated that the strength and endurance of the operated elbow joint was fully restored with even higher ratings compared to the contralateral healthy arm. The described reconstruction technique can be considered as an advisable option in high-performance athletes with underlying poor tendon quality due to high tensile strength and lack of donor site morbidity, thus enabling them to restore preinjury status and achieve safe return to sports. PMID:24711944

  12. A comparison of physical examinations with musculoskeletal ultrasound in the diagnosis of biceps long head tendinitis.

    Science.gov (United States)

    Chen, Hung-Sheng; Lin, Shu-Hsien; Hsu, Yen-Hsia; Chen, Shih-Ching; Kang, Jiunn-Horng

    2011-09-01

    Provocative tests are useful in diagnosing biceps tendon tendinitis. This is the first study to establish the reliability of these tests by comparing the resuts with musculoskeletal ultrasound (US) findings. This study examined 125 patients (69 women and 56 men) and 143 shoulders with shoulder pain. Yergason's test, Speed's test and a bicipital groove tenderness test were performed and musculoskeletal US findings were used as standard reference. Biceps tendon tendinitis was diagnosed with US in 39.1% of the patients and, of those, 55.3% had coexisting rotator cuff injury. The sensitivity and specificity of Yergason's test were 32% and 78%, respectively. The sensitivity and specificity of Speed's test were 63% and 58%, respectively. In conclusion, all three tests are limited by poor sensitivity. US can be an image modality choice in diagnosing biceps pathology. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Influence of the position of the foot on MRI signal in the deep digital flexor tendon and collateral ligaments of the distal interphalangeal joint in the standing horse.

    Science.gov (United States)

    Spriet, M; Zwingenberger, A

    2009-05-01

    Hyperintense signal is sometimes observed in ligaments and tendons of the equine foot on standing magnetic resonance examination without associated changes in size and shape. In such cases, the presence of a true lesion or an artifact should be considered. A change in position of a ligament or tendon relative to the magnetic field can induce increased signal intensity due to the magic angle effect. To assess if positional rotation of the foot in the solar plane could be responsible for artifactual changes in signal intensity in the collateral ligaments of the distal interphalangeal joint and in the deep digital flexor tendon. Six isolated equine feet were imaged with a standing equine magnetic resonance system in 9 different positions with different degrees of rotation in the solar plane. Rotation of the limb induced a linear hyperintense signal on all feet at the palmar aspect of one of the lobes of the deep digital flexor tendon and at the dorsal aspect of the other lobe. Changes in signal intensity in the collateral ligaments of the distal interphalangeal joint occurred with rotation of the limb only in those feet where mediolateral hoof imbalance was present. The position and conformation of the foot influence the signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint. The significance of increased signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint should be interpreted with regard to the position and the conformation of the foot.

  14. MRI of the rotator interval of the shoulder

    International Nuclear Information System (INIS)

    Lee, J.C.; Guy, S.; Connell, D.; Saifuddin, A.; Lambert, S.

    2007-01-01

    The rotator interval of the shoulder joint is located between the distal edges of the supraspinatus and subscapularis tendons and contains the insertions of the coracohumeral and superior glenohumeral ligaments. These structures form a complex pulley system that stabilizes the long head of the biceps tendon as it enters the bicipital groove of the humeral head. The rotator interval is the site of a variety of pathological processes including biceps tendon lesions, adhesive capsulitis and anterosuperior internal impingement. This article describes the anatomy, function and pathology of the rotator interval using magnetic resonance imaging (MRI)

  15. Complete rupture of the distal semimembranosus tendon with secondary hamstring muscles atrophy: MR findings in two cases

    International Nuclear Information System (INIS)

    Varela, J.R.; Rodriguez, E.; Soler, R.; Gonzalez, J.; Pombo, S.

    2000-01-01

    Complete rupture of the hamstring muscles is a rare injury. The proximal musculo-tendinous junction is the most frequent site of rupture. We present two cases of complete rupture of the distal semimenbranosus tendon, which clinically presented as soft-tissue masses. MR imaging permitted the correct diagnosis. There has been only one other such case reported. (orig.)

  16. Complete rupture of the distal semimembranosus tendon with secondary hamstring muscles atrophy: MR findings in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Varela, J.R.; Rodriguez, E.; Soler, R.; Gonzalez, J.; Pombo, S. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain)

    2000-06-01

    Complete rupture of the hamstring muscles is a rare injury. The proximal musculo-tendinous junction is the most frequent site of rupture. We present two cases of complete rupture of the distal semimenbranosus tendon, which clinically presented as soft-tissue masses. MR imaging permitted the correct diagnosis. There has been only one other such case reported. (orig.)

  17. Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.

    Science.gov (United States)

    Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron

    2012-01-01

    Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Arthroscopic proximal versus open subpectoral biceps tenodesis with arthroscopic repair of small- or medium-sized rotator cuff tears.

    Science.gov (United States)

    Yi, Young; Lee, Jong-Myoung; Kwon, Seok Hyun; Kim, Jeong-Woo

    2016-12-01

    The study was aimed to compare arthroscopic proximal biceps tenodesis and open subpectoral biceps tenodesis in repair of small or medium rotator cuff tears. Eighty-five patients underwent biceps tenodesis with arthroscopic repair of a rotator cuff tear, and 66 patients were followed for median of 26.8 (18-42) months with ultrasonography were reviewed. The arthroscopic biceps tenodesis group included 34 cases, and the open subpectoral biceps group included 32 cases. Patients were evaluated using visual analogue scale (VAS), American Shoulder and Elbow Surgeons (ASES), and constant scores. Rotator cuff repair and fixation of the biceps tendon were assessed by ultrasonography. Fixation failure and degree of deformity were evaluated by the pain in the bicipital groove and biceps apex distance (BAD). VAS score and tenderness at the bicipital groove decreased significantly in the open subpectoral group at 3 months postoperative. In both groups, the range of motion, ASES score, and constant score increased significantly (P tendinitis and using intra-bicipital groove tenodesis technique. III.

  19. Long bicipital tendon of the shoulder: normal anatomy and pathologic findings on MR imaging.

    Science.gov (United States)

    Erickson, S J; Fitzgerald, S W; Quinn, S F; Carrera, G F; Black, K P; Lawson, T L

    1992-05-01

    The tendon of the long head of the biceps muscle (long bicipital tendon) has a complex course from its muscle belly to its insertion onto the supraglenoid tubercle/glenoid labrum. It is stabilized by numerous tendinous and ligamentous structures and is, in turn, partly responsible for maintenance of normal glenohumeral function. In this report we describe the anatomy of this tendon, correlating high-resolution MR images with cryomicrotome sections. We illustrate typical MR findings in pathologic conditions affecting the long bicipital tendon sheath, the substance of the tendon, and finally the tendon position.

  20. Reconstrucción y restauración de la rotura aguda del tendón rotuliano con aumento del tendon semitendinoso preservando su inserción distal. Reporte de un caso.[Reconstruction and repair of acute patellar tendon ruptures with semitendinosus autograft].

    Directory of Open Access Journals (Sweden)

    Víctor Andres Ciccarello

    2016-11-01

    Full Text Available Se presenta un caso de ruptura aguda de tendon rotuliano con mala calidad de tejido remanente , en la que se realiza una tecnica de restauración y aumentación con injerto del tendon semitendinoso ipsilateral , preservando su inseríón distal.

  1. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Tadros, Anthony S.; Huang, Brady K. [University of California, Department of Radiology, San Diego, CA (United States); Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan [Scripps Clinic, Department of Orthopedic Surgery, La Jolla, CA (United States); Chang, Eric Y. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California, Department of Radiology, San Diego, CA (United States)

    2015-09-15

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  2. Long head of the biceps brachii tendon: unenhanced MRI versus direct MR arthrography

    International Nuclear Information System (INIS)

    Tadros, Anthony S.; Huang, Brady K.; Wymore, Lucas; Hoenecke, Heinz; Fronek, Jan; Chang, Eric Y.

    2015-01-01

    We sought to determine the diagnostic accuracy of unenhanced MRI and direct MR arthrography (MRA) for evaluation of the intra-articular long head of the biceps brachii tendon (LHBT) using arthroscopy as the gold standard. A retrospective review of patients who underwent shoulder MRI (n = 132) and MRA (n = 67) within 12 months prior to arthroscopy was performed. MR images were independently reviewed by two blinded musculoskeletal radiologists. Routinely recorded arthroscopic photos/videos were reviewed by an orthopedic surgeon. The LHBT was graded as normal, tendinosis, partial thickness tear less or greater than 50 %, and complete tear. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for tendinosis and tear detection were calculated. MRI correctly diagnosed fewer normal LHBTs compared to MRA (39-54 % versus 74-84 %, respectively; p < 0.005). MRI and MRA did not differ significantly in the diagnosis of tendinosis (18-36 % and 15-38 %, respectively; p > 0.05) and tears (75-83 % and 64-73 %, respectively; p > 0.05). For tendinosis, MRI versus MRA showed 18-36 % and 15-38 % sensitivity, 69-79 % and 83-91 % specificity, 22-28 % and 18-50 % PPV, 74-76 % and 80-86 % NPV, and 61-64 % and 70-81 % accuracy; respectively. For tears, MRI versus MRA showed 75-83 % and 64-73 % sensitivity, 73-75 % and 82-91 % specificity, 66-69 % and 41-62 % PPV, 82-87 % and 92-94 % NPV, and 74-78 % and 79-88 % accuracy; respectively. No significant difference was found between unenhanced MRI and direct MRA for the detection of tendinosis and tears of LHBTs. (orig.)

  3. MRI study of associated shoulder pathology in patients with full-thickness subscapularis tendon tears.

    Science.gov (United States)

    Li, Xinning; Fallon, Jonathan; Egge, Natalie; Curry, Emily J; Patel, Ketan; Owens, Brett D; Busconi, Brian D

    2013-01-01

    Subscapularis tendon tears are a well-established cause of shoulder pain. The objective of the current study was to evaluate the associated shoulder pathology in patients with full-thickness subscapularis tendon tears using magnetic resonance imaging. Forty-seven magnetic resonance imaging studies taken between 2008 and 2009 with a diagnosis of full-thickness subscapularis tendon tears were reviewed. The size of the subscapularis tendon tear, amount of muscle volume loss, Goutallier grade, biceps tendon pathology, coracohumeral distance, and associated rotator cuff tears were recorded. Statistical analysis was performed. Patients 55 years and older vs those 54 years and younger had an average subscapularis tear size of 35 vs 19 mm, an average Goutallier grade of 2.7 vs 0.8, and a total muscle volume loss of 25% vs 5%, respectively. Patients with a dislocated vs normal biceps tendons had an average subscapularis tear size of 37 vs 23 mm, an average Goutallier grade of 3 vs 0.9, and a total muscle volume loss of 28% vs 7%, respectively. Patients with vs without concomitant rotator cuff tears had an average subscapularis tear size of 32 vs 17 mm, an average Goutallier grade of 2.3 vs 0.6, and a total muscle volume loss of 21% vs 3%, respectively. Overall average coracohumeral distance measured in the axial plane was 10.8±4.6 mm. Average coracaohumeral distance was 14.8 vs 8.1 mm in patients with a Goutallier grade of 0 vs 3 or 4, resepectively, and 13.6 vs 8.5 mm in patients with no rotator cuff tear vs those with a supra- and infraspinatus tear, respectively. Increased age, dislocated biceps tendons, and concomitant rotator cuff tears in patients with full-thickness subscapularis tendon tears are associated with larger subscapularis tendon tear size, higher Goutallier grades, and increased subscapularis muscle volume loss. Decreased coracohumeral distance is associated with a higher Goutallier grade and rotator cuff tears. Copyright 2013, SLACK Incorporated.

  4. Magnetic Resonance Imaging Currently Fails to Fully Evaluate the Biceps-Labrum Complex and Bicipital Tunnel.

    Science.gov (United States)

    Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J

    2016-02-01

    To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. Slap Lesions in Middle-aged Patients: Biceps Repair or Tenodesis? What Should We Perform for Long Biceps Tendon?

    Directory of Open Access Journals (Sweden)

    Sergi Sastre

    2015-12-01

    Conclusion: Biceps tenodesis is a feasible therapeutic alternative to anatomical repair for the treatment of SLAP lesions in middle-aged patients; the reinsertion failure rates for this type of lesion are rather discouraging due to the high percentage of revision surgeries that must be carried out after the primary intervention.

  6. Free Biceps Tendon Autograft to Augment Arthroscopic Rotator Cuff Repair

    OpenAIRE

    Obma, Padraic R.

    2013-01-01

    Arthroscopic rotator cuff repairs have become the standard of treatment for all sizes of tears over the past several years. Current healing rates reported in the literature are quite good, but improving the healing potential of rotator cuff repairs remains a challenging problem. There has been an increase recently in the use of augmentation of rotator cuff repairs with xenografts or synthetics for large and massive tears. Biceps tenodesis is often indicated as part of the treatment plan while...

  7. Regional strain variations in the human patellar tendon.

    Science.gov (United States)

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  8. A Review of Recent Advances in the Diagnosis and Treatment Modalities for Long Head of Bicep Tendinopathy

    Directory of Open Access Journals (Sweden)

    Robert B. Lewis

    2016-01-01

    Full Text Available This article reviews the assessment and management of the pathology of the long head of the biceps tendon, a disease commonly encountered by primary care physicians and orthopedic surgeons. We include a discussion of relevant anatomy, function, pathoanatomy, natural history of the disease, diagnostic methods, and treatment options. Recent literature on the function of the long head of the bicep (LHB is reviewed. Literature on our evolving understanding of the pathoanatomy behind LHB tendinopathy is discussed. We also discuss the effectiveness of current diagnostic and treatment modalities.

  9. Hypertrophy of the extra-articular tendon of the long head of biceps correlates with the location and size of a rotator cuff tear.

    Science.gov (United States)

    Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y

    2017-06-01

    The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.

  10. Anatomic relationship of the proximal nail matrix to the extensor hallucis longus tendon insertion.

    Science.gov (United States)

    Palomo López, P; Becerro de Bengoa Vallejo, R; López López, D; Prados Frutos, J C; Alfonso Murillo González, J; Losa Iglesias, M E

    2015-10-01

    The purpose of this study was to delineate the relationship of the terminal extensor hallucis longus tendon insertion to the proximal limit of the nail matrix of the great toe. Fifty fresh-frozen human cadaver great toes with no evidence of trauma (average age, 62.5 years; 29 males and 21 females) were used for this study. Under 25X magnification, the proximal limit of the nail matrix and the terminal bony insertion of the extensor hallucis longus tendons were identified. The distance from the terminal tendon insertion to the nail matrix was ascertained using precision calipers, an optical microscope, and autocad(®) software for windows. Twenty-five great toes were placed in a neutral formalin solution and further analysed by histological longitudinal-sections. The specimens were stained with haematoxylin and eosin and examined microscopically to determine the presence of the extensor hallucis longus tendon along the dorsal aspect of the distal phalanx of each great toe. The main result we found in great toes was that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx in all, 100%, specimens. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of the distal phalanx as is the case for fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. We have found that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of distal phalanx as is the case in fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. Our anatomic study demonstrates that the proximal limit of the matrix and nail bed of the human great toe are dorsal and

  11. Differences in tendon properties in elite badminton players with or without patellar tendinopathy.

    Science.gov (United States)

    Couppé, C; Kongsgaard, M; Aagaard, P; Vinther, A; Boesen, M; Kjaer, M; Magnusson, S P

    2013-03-01

    The aim of this study was to examine the structural and mechanical properties of the patellar tendon in elite male badminton players with and without patellar tendinopathy. Seven players with unilateral patellar tendinopathy (PT group) on the lead extremity (used for forward lunge) and nine players with no current or previous patellar tendinopathy (CT group) were included. Magnetic resonance imaging was used to assess distal patellar tendon dimensions. Patellar tendon mechanical properties were assessed using simultaneous tendon force and deformation measurements. Distal tendon cross-sectional area (CSA) normalized for body weight (mm(2) /kg(2/3) ) was lower in the PT group compared with the CT group on both the non-lead extremity (6.1 ± 0.3 vs 7.4 ± 0.2, P < 0.05) and the lead extremity (6.5 ± 0.6 vs 8.4 ± 0.3, P < 0.05). Distal tendon stress was higher in the PT group compared with the CT group for both the non-lead extremity (31 ± 1 vs 27 ± 1 MPa, P < 0.05) and the lead extremity (32 ± 3 vs 21 ± 3 MPa, P < 0.01). Conclusively, the PT group had smaller distal patellar tendon CSA on both the injured (lead extremity) and the uninjured side (non-lead extremity) compared with the CT group. Subsequently, the smaller CSA yielded a greater distal patellar tendon stress in the PT group. Therefore, a small tendon CSA may predispose to the development of tendinopathy. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  12. Can Achilles tendon be used as a new distal landmark for coronal tibial component alignment in total knee replacement surgery? An observational MRI study

    Directory of Open Access Journals (Sweden)

    Tiftikçi U

    2017-01-01

    Full Text Available Uğur Tiftikçi,1 Sancar Serbest,1 Veysel Burulday2 1Department of Orthopaedics and Traumatology, 2Department of Radiology, Faculty of Medicine, Kırıkkale University, Kırıkkale, Turkey Background: In total knee arthroplasty, it is better to use more than one reference point for correct alignment of the components. By measuring the distances of Achilles tendon (AT and other conventional landmarks from the mechanical axis in magnetic resonance imaging (MRI of the ankle, we aimed to demonstrate that, as a novel landmark which can help for correct alignment in the coronal plane, AT is a better option than other landmarks. Materials and methods: This retrospective study was done on 53 ankle MRIs that met the criteria for inclusion to the study among 158 ankle MRIs. After identification of the mechanical axis, the distances of distal landmarks, which were extensor hallucis longus tendon (EHLT, tibialis anterior tendon (TAT, dorsalis pedis artery (DPA, AT, extensor digitorum longus tendon (EDLT, and malleoli, were measured from the mechanical axis and were statistically evaluated. Results: In proximal measurements, the distances of the landmarks to the mechanical axis (on average were AT, 2.64±1.62 mm lateral; EHLT, 3.89±2.45 mm medial; DPA, 4.69±2.39 mm medial; TAT, 8.24±3.60 mm medial; and EDLT, 14.2±4.14 mm lateral (P<0.001. In distal measurements, the distances of the landmarks to the mechanical axis (on average were AT, 1.99±1.24 mm medial; EHLT, 4.27±2.49 mm medial; DPA, 4.79±2.10 mm medial; TAT, 12.9±4.07 mm medial; and EDLT, 12.18±4.17 mm lateral (P<0.001. Conclusion: In this study, the mechanical axis line, which is the center of talus, passes through the AT. Our MRI investigations showed that the AT, EHLT, DPA, and malleolar center (3–5 mm medial may help in correct alignment. Keywords: total knee arthroplasty, tibial component, alignment, distal references, landmark, MRI, Achilles tendon

  13. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    Science.gov (United States)

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  14. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    Science.gov (United States)

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  15. The MR arthrographic anatomy of the biceps labral insertion and its morphological significance with labral tears in patients with shoulder instability

    International Nuclear Information System (INIS)

    Jakanani, G.C.; Botchu, R.; Rennie, W.J.

    2012-01-01

    Introduction: Most of the fibres of the long head of biceps tendon attach on the superior labrum just posterior to the supraglenoid tubercle. Aim: Our hypothesis was that posteriorly attached biceps tendons predispose to posterior superior labral tears and SLAP lesions. Methods and materials: A prospective analysis of all MR shoulder arthrograms for shoulder instability referred from the shoulder specialist clinics, performed during a one year period were reviewed by two independent observers who were blinded to clinical history. The biceps attachment was classified into four groups according to the method described in an earlier cadaveric study into four groups; posterior-type 1, predominantly posterior-type 2, equal contributions to both anterior and posterior labrum-type 3 and predominantly anterior labral attachment-type 4. Data was analysed using Kappa statistics and Fischer's exact test. Results: 48 patients (33 males and 15 females) were included in this study with a mean age of 32 years. Majority, 22 patients (46%) had a type 1 attachment of the biceps on the superior labrum. There was moderate intra-observer and good interobserver agreement with a Kappa of 0.58 and 0.63 respectively. There was a significant association between a type 2 attachment and posterior tears (p ≤ 0.04) and also between a type 2 attachment and SLAP tears (p ≤ 0.04). Conclusion: Our results suggest that variation in anatomy of biceps origin influences the type of labral tears that occur in patients with shoulder instability. The importance of these findings could influence selection of individuals in throwing sports like cricket and baseball.

  16. The MR arthrographic anatomy of the biceps labral insertion and its morphological significance with labral tears in patients with shoulder instability

    Energy Technology Data Exchange (ETDEWEB)

    Jakanani, G.C., E-mail: gcjakanani@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom); Botchu, R., E-mail: drrajeshb@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom); Rennie, W.J., E-mail: winston.rennie@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom)

    2012-11-15

    Introduction: Most of the fibres of the long head of biceps tendon attach on the superior labrum just posterior to the supraglenoid tubercle. Aim: Our hypothesis was that posteriorly attached biceps tendons predispose to posterior superior labral tears and SLAP lesions. Methods and materials: A prospective analysis of all MR shoulder arthrograms for shoulder instability referred from the shoulder specialist clinics, performed during a one year period were reviewed by two independent observers who were blinded to clinical history. The biceps attachment was classified into four groups according to the method described in an earlier cadaveric study into four groups; posterior-type 1, predominantly posterior-type 2, equal contributions to both anterior and posterior labrum-type 3 and predominantly anterior labral attachment-type 4. Data was analysed using Kappa statistics and Fischer's exact test. Results: 48 patients (33 males and 15 females) were included in this study with a mean age of 32 years. Majority, 22 patients (46%) had a type 1 attachment of the biceps on the superior labrum. There was moderate intra-observer and good interobserver agreement with a Kappa of 0.58 and 0.63 respectively. There was a significant association between a type 2 attachment and posterior tears (p {<=} 0.04) and also between a type 2 attachment and SLAP tears (p {<=} 0.04). Conclusion: Our results suggest that variation in anatomy of biceps origin influences the type of labral tears that occur in patients with shoulder instability. The importance of these findings could influence selection of individuals in throwing sports like cricket and baseball.

  17. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    Science.gov (United States)

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  18. Changes in hip joint muscle-tendon lengths with mode of locomotion.

    Science.gov (United States)

    Riley, Patrick O; Franz, Jason; Dicharry, Jay; Kerrigan, D Casey

    2010-02-01

    We have reported that peak hip extension is nearly identical in walking and running, suggesting that anatomical constraints, such as flexor muscle tightness may limit the range of hip extension. To obtain a more mechanistic insight into mobility at the hip and pelvis we examined the lengths of the muscle-tendons units crossing the hip joint. Data defining the three-dimensional kinematics of 26 healthy runners at self-selected walking and running speeds were obtained. These data were used to scale and drive musculoskeletal models using OpenSIM. Muscle-tendon unit (MTU) lengths were calculated for the trailing limb illiacus, rectus femoris, gluteus maximus, and biceps femoris long head and the advancing limb biceps femoris and gluteus maximus. The magnitude and timing of MTU length peaks were each compared between walking and running. The peak length of the right (trailing limb) illiacus MTU, a pure hip flexor, was nearly identical between walking and running, while the maximum length of the rectus femoris MTU, a hip flexor and knee extensor, increased during running. The maximum length of the left (leading limb) biceps femoris was also unchanged between walking and running. Further, the timing of peak illiacus MTU length and peak contralateral biceps femoris MTU length occurred essentially simultaneously during running, at a time during gait when the hamstrings are most vulnerable to stretch injury. This latter finding suggests exploring the role for hip flexor stretching in combination with hamstring stretching to treat and/or prevent running related hamstring injury. Copyright 2009 Elsevier B.V. All rights reserved.

  19. Separation and estimation of muscle spindle and tension receptor populations by vibration of the biceps muscle in the frog.

    Science.gov (United States)

    Giszter, S F; Kargo, W J

    2002-10-01

    Frog spinal cord reflex behaviors have been used to test the idea of spinal primitives. We have suggested a significant role for proprioception in regulation of primitives. However the in vivo behavior of spindle and golgi tendon receptors in frogs in response to vibration are not well described and the proportions of these proprioceptors are not established. In this study, we examine the selectivity of muscle vibration in the spinal frog. The aim of the study was (1) to examine how hindlimb muscle spindles and GTO receptors are activated by muscle vibration and (2) to estimate the relative numbers of GTO receptors and spindle afferents in a selected muscle, for comparison with the mammal. Single muscle afferents from the biceps muscle were identified in the dorsal roots. These were tested in response to biceps vibration, intramuscular stimulation and biceps nerve stimulation. Biceps units were categorized into two types: First, spindle afferents which had a high conduction velocity (approximately 20-30 m/s), responded reliably (were entrained 1:1) to muscle vibration, and exhibited distinct pauses to shortening muscle contractions. Second, golgi tendon organ afferents, which had a lower conduction velocity (approximately 10-20 m/s), responded less reliably to muscle vibration at physiologic muscle lengths, but responded more reliably at extended lengths or with background muscle contraction, and exhibited distinct bursts to shortening muscle contractions. Vibration responses of these units were tested with and without muscle curarization. Ensemble (suction electrode) recordings from the dorsal roots were used to provide rough estimates of the proportions of the two muscle afferent types.

  20. Evaluation of the hamstring muscles after injury

    International Nuclear Information System (INIS)

    Koulouris, G.; Connell, D.; Burke, F.; Young, D.

    2002-01-01

    Full text: The aim of this study was to describe the imaging findings following acute hamstring injury. We retrospectively reviewed the imaging findings of 224 examinations in 208 patients (192 male, 16 female, mean age 28.2 years). MR imaging was performed in 102 cases and sonography in 156 cases (both modalities were performed in 34 examinations). The mean duration of symptoms was 4.7 days (range 1-10 days). Attention was directed to the frequency of muscle movement, the location of the injury within the musculotendinous unit, the extent of the injury and discriminating avulsion from musculotendinous injury. Sixteen patients underwent surgery. The biceps femoris was the most common muscle injured (150/224). Sixteen patients with surgical confirmation of a hamstring avulsion from the ischial tuberosity (14 conjoint, 2 biceps alone) were reliably diagnosed with MR imaging (16/16), but less so with ultrasound (7/12). Eighty-six patients (86/150) had injuries of the musculotendinous junction of biceps, 51/150 myofascial injuries and 13/150 muscle belly alone. Proximal injuries of the biceps were more common that the distal. Sixty-eight patients had injuries of semitendinosus and eight patients semimebranosus.The semitendinosus muscle was more often injured in the distal half of the muscle (42/68) as was semimebranosus (7/8). Three patients had a distal rupture of semitendinosus muscle with retraction. Haematoma was a common finding (170/224) and often tracked around the myofascial layer.This was felt to be a reliable sign for hamstring injury. Discriminating a hamstring tendon avulsion from myotendinous strain is important as these patients necessitate surgical management as opposed to conservative treatment. MR imaging is the preferred modality in the investigation of hamstring muscle and tendon injury. Ultrasound has a complimentary role and may be used to monitor hamstring tendon injuries prior to return to competitive sport. Copyright (2002) Blackwell Science Pty

  1. A functional-anatomical approach to the spine-pelvis mechanism: interaction between the biceps femoris muscle and the sacrotuberous ligament.

    Science.gov (United States)

    van Wingerden, J P; Vleeming, A; Snijders, C J; Stoeckart, R

    1993-10-01

    Summary. Sacroiliac joint dysfunction is often overlooked as a possible cause of low back pain. This is due to the use of reductionistic anatomical models. From a kinematic point of view, topographic anatomical models are generally inadequate since they categorize pelvis, lower vertebral column and legs as distinct entities. This functional-anatomical study focuses on the question whether anatomical connections between the biceps femoris muscle and the sacrotuberous ligament are kinematically useful. Forces applied to the tendon of the biceps femoris muscle, simulating biceps femoris muscle force, were shown to influence sacrotuberous ligament tension. Since sacrotuberous ligament tension influences sacroiliac joint kinematics, hamstring training could influence the sacroiliac joint and thus low back kinematics. The clinical implications with respect to 'short' hamstrings, pelvic instability and walking are discussed.

  2. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  3. Histochemistry profile of the biceps brachii muscle fibres of capuchin monkeys (Cebus apella, Linnaeus, 1758

    Directory of Open Access Journals (Sweden)

    CHF Bortoluci

    Full Text Available A general analysis of the behaviour of “Cebus” shows that when this primate moves position to feed or perform another activity, it presents different ways of locomotion. This information shows that the brachial biceps muscle of this animal is frequently used in their locomotion activities, but it should also be remembered that this muscle is also used for other development activities like hiding, searching for objects, searching out in the woods, and digging in the soil. Considering the above, it was decided to research the histoenzimologic characteristics of the brachial biceps muscle to observe whether it is better adpted to postural or phasic function. To that end, samples were taken from the superficial and deep regions, the inserts proximal (medial and lateral and distal brachial biceps six capuchin monkeys male and adult, which were subjected to the reactions of m-ATPase, NADH-Tr. Based on the results of these reactions fibres were classified as in Fast Twitch Glycolitic (FG, Fast Twitch Oxidative Glycolitic (FOG and Slow Twitc (SO. In general, the results, considering the muscle as a whole, show a trend of frequency FOG> FG> SO. The data on the frequency were studied on three superficial regions FOG=FG>SO; the deep regions of the inserts proximal FOG=FG=SO and inserting the distal FOG>FG=SO. In conclusion, the biceps brachii of the capuchin monkey is well adapted for both postural and phasic activities.

  4. Histochemistry profile of the biceps brachii muscle fibres of capuchin monkeys (Cebus apella, Linnaeus, 1758).

    Science.gov (United States)

    Bortoluci, C H F; Simionato, L H; Rosa Junior, G M; Oliveira, J A; Lauris, J R P; Moraes, L H R; Rodrigues, A C; Andreo, J C

    2014-08-01

    A general analysis of the behaviour of "Cebus" shows that when this primate moves position to feed or perform another activity, it presents different ways of locomotion. This information shows that the brachial biceps muscle of this animal is frequently used in their locomotion activities, but it should also be remembered that this muscle is also used for other development activities like hiding, searching for objects, searching out in the woods, and digging in the soil. Considering the above, it was decided to research the histoenzimologic characteristics of the brachial biceps muscle to observe whether it is better adpted to postural or phasic function. To that end, samples were taken from the superficial and deep regions, the inserts proximal (medial and lateral) and distal brachial biceps six capuchin monkeys male and adult, which were subjected to the reactions of m-ATPase, NADH-Tr. Based on the results of these reactions fibres were classified as in Fast Twitch Glycolitic (FG), Fast Twitch Oxidative Glycolitic (FOG) and Slow Twitc (SO). In general, the results, considering the muscle as a whole, show a trend of frequency FOG> FG> SO. The data on the frequency were studied on three superficial regions FOG=FG>SO; the deep regions of the inserts proximal FOG=FG=SO and inserting the distal FOG>FG=SO. In conclusion, the biceps brachii of the capuchin monkey is well adapted for both postural and phasic activities.

  5. A practical, evidence-based, comprehensive (PEC) physical examination for diagnosing pathology of the long head of the biceps.

    Science.gov (United States)

    Rosas, Samuel; Krill, Michael K; Amoo-Achampong, Kelms; Kwon, KiHyun; Nwachukwu, Benedict U; McCormick, Frank

    2017-08-01

    Clinical examination of the shoulder joint has gained attention as clinicians aim to use an evidence-based examination of the biceps tendon, with the desire for a proper diagnosis while minimizing costly imaging procedures. The purpose of this study is to create a decision tree analysis that enables the development of a clinical algorithm for diagnosing long head of biceps (LHB) pathology. A literature review of Level I and II diagnostic studies was conducted to extract characteristics of clinical tests for LHB pathology through a systematic review of PubMed, Medline, Ovid, and Cochrane Review databases. Tests were combined in series and parallel to determine sensitivities and specificities, and positive and negative likelihood ratios were determined for each combination using a subjective pretest probability. The "gold standard" for diagnosis in all included studies was arthroscopy or arthrotomy. The optimal testing modality was use of the uppercut test combined with the tenderness to palpation of the biceps tendon test. This combination achieved a sensitivity of 88.4% when performed in parallel and a specificity of 93.8% when performed in series. These tests used in combination optimize post-test probability accuracy greater than any single individual test. Performing the uppercut test and biceps groove tenderness to palpation test together has the highest sensitivity and specificity of known physical examinations maneuvers to aid in the diagnosis of LHB pathology compared with diagnostic arthroscopy (practical, evidence-based, comprehensive examination). A decision tree analysis aides in the practical, evidence-based, comprehensive examination diagnostic accuracy post-testing based on the ordinal scale pretest probability. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Biceps Tendon Lengthening Surgery for Failed Serial Casting Patients With Elbow Flexion Contractures Following Brachial Plexus Birth Injury.

    Science.gov (United States)

    Nath, Rahul K; Somasundaram, Chandra

    2016-01-01

    Assessment of surgical outcomes of biceps tendon lengthening (BTL) surgery in obstetric brachial plexus injury (OBPI) patients with elbow flexion contractures, who had unsuccessful serial casting. Serial casting and splinting have been shown to be effective in correcting elbow flexion contractures in OBPI. However, the possibilities of radial head dislocations and other complications have been reported in serial casting and splinting. Literature indicates surgical intervention when such nonoperative techniques and range-of-motion exercises fail. Here, we demonstrated a significant reduction of the contractures of the affected elbow and improvement in arm length to more normal after BTL in these patients, who had unsuccessful serial casting. Ten OBPI patients (6 girls and 4 boys) with an average age of 11.2 years (4-17.7 years) had BTL surgery after unsuccessful serial casting. Mean elbow flexion contracture was 40° before and 37° (average) after serial casting. Mean elbow flexion contracture was reduced to 8° (0°-20°) post-BTL surgical procedure with an average follow-up of 11 months. This was 75% improvement and statistically significant (P casting. These OBPI patients in our study had 75% significant reduction in elbow flexion contractures and achieved an improved and more normal length of the affected arm after the BTL surgery when compared to only 7% insignificant reduction and no improvement in arm length after serial casting.

  7. Tenodesis of the long head of the biceps brachii for chronic bicipital tendinitis. Long-term results.

    Science.gov (United States)

    Becker, D A; Cofield, R H

    1989-03-01

    Fifty-four shoulders in fifty-one patients were followed for an average of thirteen years (range, two to twenty-three years) after surgical tenodesis of the long head of the biceps brachii for the treatment of chronic tendinitis. At an average of six months postoperatively, in all but three shoulders (forty-eight patients) some benefit was evident. However, after a longer follow-up, a satisfactory result was achieved in only twenty-eight shoulders (approximately 50 per cent). About one-third of the shoulders continued to be pain-free, and in eight shoulders (15 per cent) an additional operation was performed. Tenodesis of the long head of the biceps tendon, therefore, was not an effective treatment for tendinitis over the long term.

  8. Magnetic resonance imaging of the elbow. Part II: Abnormalities of the ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Tuite, Michael; Sanford, Matthew [University of Wisconsin Hospital, Department of Radiology, Madison, WI (United States)

    2005-01-01

    Part II of this comprehensive review on magnetic resonance imaging of the elbow discusses the role of magnetic resonance imaging in evaluating patients with abnormalities of the ligaments, tendons, and nerves of the elbow. Magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the soft tissue structures of the elbow. Magnetic resonance imaging can detect tears of the ulnar collateral ligament and lateral collateral ligament of the elbow with high sensitivity and specificity. Magnetic resonance imaging can determine the extent of tendon pathology in patients with medial epicondylitis and lateral epicondylitis. Magnetic resonance imaging can detect tears of the biceps tendon and triceps tendon and can distinguishing between partial and complete tendon rupture. Magnetic resonance imaging is also helpful in evaluating patients with nerve disorders at the elbow. (orig.)

  9. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    Science.gov (United States)

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P tendon length and strain at all contraction intensities after eccentric exercise (P tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Trauma and sports injuries of the elbow

    NARCIS (Netherlands)

    Kodde, I.F.

    2016-01-01

    This thesis deals with current issues in the management of trauma and sports injuries of the elbow. Common sports injuries of the elbow involve ruptures of the distal biceps tendon and the ulnar collateral ligament. We evaluated one of the current thoughts, that the height of the radial bicipital

  11. Complex distal insertions of the tibialis posterior tendon: detailed anatomic and MR imaging investigation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Pastore, Daniel; Cerri, Giovanni G. [University of Sao Paulo, Department of Radiology, Sao Paulo, Sao Paulo (Brazil); VA Medical Center, University of California, Department of Radiology, San Diego, CA (United States); Dirim, Berna; Wangwinyuvirat, Mani; Belentani, Clarissa L.; Trudell, Debra J.; Resnick, Donald L. [VA Medical Center, University of California, Department of Radiology, San Diego, CA (United States); Haghighi, Parviz [VA Medical Center, University of California, Department of Radiology, San Diego, CA (United States); VA Medical Center, University of California, Department of Histology, San Diego, CA (United States)

    2008-09-15

    The purpose of this report was to demonstrate the normal complex insertional anatomy of the tibialis posterior tendon (TPT) in cadavers using magnetic resonance (MR) imaging with anatomic and histologic correlation. Ten cadaveric ankles were used according to institutional guidelines. MR T1-weighted spin echo imaging was performed to demonstrate aspects of the complex anatomic distal insertions of the TPT in cadaveric specimens. Findings on MR imaging were correlated with those derived from anatomic and histologic study. Generally, the TPT revealed a low signal in all MR images, except near the level of the medial malleolus, where the TPT suddenly changed direction and ''magic angle'' artifact could be observed. In five out of ten specimens (50%), a type I accessory navicular bone was found in the TPT. In all cases with a type I accessory navicular bone, the TPT had an altered signal in this area. Axial and coronal planes on MR imaging were the best in identifying the distal insertions of the TPT. A normal division of the TPT was observed just proximal to the insertion into the navicular bone in five specimens (100%) occurring at a maximum proximal distance from its attachment to the navicular bone of approximately 1.5 to 2 cm. In the other five specimens, in which a type I accessory navicular bone was present, the TPT directly inserted into the accessory bone and a slip less than 1.5 mm in thickness could be observed attaching to the medial aspect of the navicular bone (100%). Anatomic inspection confirmed the sites of the distal insertions of the components of the TPT. MR imaging enabled detailed analysis of the complex distal insertions of the TPT as well as a better understanding of those features of its insertion that can simulate a lesion. (orig.)

  12. Correlation of the SLAP lesion with lesions of the medial sheath of the biceps tendon and intra-articular subscapularis tendon

    Directory of Open Access Journals (Sweden)

    Bennett William

    2009-01-01

    Full Text Available Background: Superior labral anterior to posterior (SLAP lesions have been well described in the literature and are thought to be secondary to traction injuries to the biceps anchor and/or falls on the outstretched arm. The pulley has recently been described as a structure that aids in the prevention of biceps instability. The intra-articular subscapularis insertion (IASS has been noted to contribute to the robust nature of the medial sheath. The purpose of the study was to determine a potential correlation of SLAP lesions and pulley lesions with/without IASS lesions, (hereafter referred to as medial sheath as forces that can disrupt the biceps anchor and may also disrupt structures of the medial sheath or vice-versa. Materials and Methods: Three hundred and sixteen consecutive shoulder arthroscopies performed by one surgeon were reviewed retrospectively. Operative reports and arthroscopic pictures were carefully reviewed with particular attention paid to the labral and pulley pathology. Selection bias was noted as the author had never operated primarily for a Type 1 SLAP lesion. Following, however, and as such, the exclusion criteria, was a Type 1 SLAP. Results: There were a total of 30 SLAP lesions and a total of 126 medial sheath lesions. There were 13 patients who had both SLAP and medial sheath lesions. There were 17 patients who had a SLAP lesion without a medial sheath lesion. There were 96 medial sheath lesions without a SLAP. A comparison of rates between patients who had a medial sheath lesion with a SLAP and those who had a medial sheath lesion without a SLAP, for the 316 patients, and when tested with a Fisher exact test revealed that there was no statistical significance, P = 0.673. The prevalence of SLAP lesions in this population of 316 patients was 9.4%, Buford 1%, medial sheath lesions 39%, and SLAP and medial sheath lesions 4%. Interestingly, there were three Buford complexes, all associated with a SLAP and one Buford complex

  13. Effects of implant material and plate design on tendon function and morphology.

    Science.gov (United States)

    Cohen, Mark S; Turner, Thomas M; Urban, Robert M

    2006-04-01

    Titanium implants are an alternative to stainless steel implants for internal fixation after fracture. The advantages of titanium include decreased implant stiffness, increased bio-compatibility, and diminished stress shielding. However, titanium has been implicated in tendon irritation and adhesions when used in the hand and wrist. We evaluated the relationship between extensor tendon morphology and dorsal plating of the distal radius in a canine model using distal radius pi plates made of stainless steel, titanium, and titanium alloy with a modified ramped edge design. We found marked histologic changes in the tendons and surrounding soft tissues including tendon deformation and degeneration (fibrillation, cartilage metaplasia, hypocellularity and hyalinization of blood vessels), peritendonous adhesions and neovascularity in the parenchyma. Only a minimal inflammatory cell infiltrate was identified and was limited to the tenosynovium and/or paratenon. No differences were identified between titanium and stainless steel implants and those with a ramped design. Although all animals lost wrist motion with time, no differences were observed between groups. Our results suggest that pi plate placement on the dorsal surface of the distal radius may lead to extensor tendon irritation and dysfunction. There is no evidence to suggest that this is specifically related to titanium or plate edge design.

  14. Anterior Interosseous Nerve Neuropraxia Secondary to Shoulder Arthroscopy and Open Subpectoral Long Head Biceps Tenodesis

    Directory of Open Access Journals (Sweden)

    Jeremiah T. Steed

    2017-01-01

    Full Text Available Arthroscopic rotator cuff tendon repair is a common elective procedure performed by trained orthopaedic surgeons with a relatively low complication rate. Specifically, isolated neuropraxia of the anterior interosseous nerve (AIN is a very rare complication of shoulder arthroscopy. An analysis of peer-reviewed published literature revealed only three articles reporting a total of seven cases that describe this specific complication following standard shoulder arthroscopic procedures. This article reports on three patients diagnosed with AIN neuropraxia following routine shoulder arthroscopy done by a single surgeon within a three-year period. All three patients also underwent open biceps tenodesis immediately following completion of the arthroscopic procedures. The exact causal mechanism of AIN neuropraxia following shoulder arthroscopy with biceps tenodesis is not known. This case report reviews possible mechanisms with emphasis on specific factors that make a traction injury the most likely etiology in these cases. We critically analyze our operating room setup and patient positioning practices in light of the existing biomechanical and cadaveric research to propose changes to our standard practices that may help to reduce the incidence of this specific postoperative complication in patients undergoing elective shoulder arthroscopy with biceps tenodesis.

  15. Distal Oblique Bundle Reinforcement for Treatment of DRUJ Instability.

    Science.gov (United States)

    Brink, Peter R G; Hannemann, Pascal F W

    2015-08-01

    Background Chronic, dynamic bidirectional instability in the distal radioulnar joint (DRUJ) is diagnosed clinically, based on the patient's complaints and the finding of abnormal laxity in the vicinity of the distal ulna. In cases where malunion is ruled out or treated and there are no signs of osteoarthritis, stabilization of the DRUJ may offer relief. To this end, several different techniques have been investigated over the past 90 years. Materials and Methods In this article we outline the procedure for a new technique using a tendon graft to reinforce the distal edge of the interosseous membrane. Description of Technique A percutaneous technique is used to harvest the palmaris longus tendon and to create a tunnel, just proximal to the sigmoid notch, through the ulna and radius in an oblique direction. By overdrilling the radial cortex, the knotted tendon can be pulled through the radius and ulna and the knot blocked at the second radial cortex, creating a strong connection between the radius and ulna at the site of the distal oblique bundle (DOB). The tendon is fixed in the ulna with a small interference screw in full supination, preventing subluxation of the ulna out of the sigmoid notch during rotation. Results Fourteen patients were treated with this novel technique between 2011 and October 2013. The QuickDASH score at 25 months postoperatively (range 16-38 months) showed an improvement of 32 points. Similarly, an improvement of 33 points (67-34 months) was found on the PRWHE. Only one recurrence of chronic, dynamic bidirectional instability in the DRUJ was observed. Conclusion This simple percutaneous tenodesis technique between radius and ulna at the position of the distal edge of the interosseous membrane shows promise in terms of both restoring stability and relieving complaints related to chronic subluxation in the DRUJ.

  16. Distal radioulnar joint: functional anatomy, including pathomechanics.

    Science.gov (United States)

    Haugstvedt, J R; Langer, M F; Berger, R A

    2017-05-01

    The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.

  17. No Telescoping Effect with Dual Tendon Vibration.

    Directory of Open Access Journals (Sweden)

    Valeria Bellan

    Full Text Available The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect. Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow, but no evidence of a contraction of the perceived arm length.

  18. Effect of acute exercise on patella tendon protein synthesis and gene expression

    DEFF Research Database (Denmark)

    Dideriksen, Kasper; Sindby, Ann Kathrine Ryberg; Krogsgaard, Michael

    2013-01-01

    Evidence suggests that habitual loading can result in patellar tendon hypertrophy, especially at the proximal and distal parts of the patellar tendon. The underlying protein kinetic changes and its regulation remains controversial and human data, investigating this topic, are limited. The present...

  19. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  20. Endoscopic Treatment of Intrasheath Peroneal Tendon Subluxation

    Directory of Open Access Journals (Sweden)

    Frederick Michels

    2013-01-01

    Full Text Available Intrasheath subluxation of the peroneal tendons within the peroneal groove is an uncommon problem. Open exploration combined with a peroneal groove-deepening procedure and retinacular reefing is the recommended treatment. This extensive lateral approach needs incision of the intact superior peroneal retinaculum and repair afterwards. We treated three patients with a painful intrasheath subluxation using an endoscopic approach. During this tendoscopy both tendons were inspected. The distal muscle fibers of the peroneus brevis tendon were resected in two patients. A partial tear was debrided in the third patient. All patients had a good result. No wound-healing problems or other complications occurred. Early return to work and sports was possible. An endoscopic approach was successful in treatment of an intrasheath subluxation of the peroneal tendons.

  1. Is Z Division of the Achilles Tendon always Necessary in Wide ...

    African Journals Online (AJOL)

    Method: From 15/12/1997 to 30/12/2006 sixteen patients required surgical management of distal tibia fractures involving articular surfaces. Posterior approach with. Achilles tendon division was indicated for satisfactory access to the back of tibia and ankle. In equal number of these patients division of the Achilles tendon ...

  2. Evaluation of the hamstring muscle complex following acute injury

    International Nuclear Information System (INIS)

    Koulouris, George; Connell, David

    2003-01-01

    To evaluate the imaging findings following acute hamstring injury. We retrospectively reviewed the imaging findings of hamstring muscle complex (HMC) strain in 170 patients referred to our institution over a 3-year period. A total of 179 injuries to the HMC were demonstrated in 170 patients (154 male, 16 female, mean age 28.2 years). The mean duration of symptoms was 4.7 days (range 1-10 days). MR imaging was performed in 97 cases and sonography in 102 cases (both modalities were performed in 20 examinations). Attention was directed to the frequency of muscle involvement, the location of the injury within the muscle-tendon unit, the extent of the injury and discriminating avulsion from muscle injury. Twenty-one patients had proximal tendon injury, with sixteen avulsions and five partial tears. Sixteen of these patients had surgical confirmation of hamstring avulsion from the ischial tuberosity (14 conjoint, 2 biceps femoris alone) and all were reliably diagnosed with MR imaging (16/16), but less so with sonography (7/12). Four distal tendon avulsions were also observed (three semitendinosus, one biceps femoris). With respect to muscle injury, the biceps femoris was most commonly injured (124/154). Semimembranosus was an uncommon muscle injury (21/154) and semitendinosus rare (9/154). Imaging can discriminate a hamstring tendon avulsion from musculotendinous strain and helps identify which patients necessitate surgical management as opposed to conservative treatment. (orig.)

  3. Evaluation of the hamstring muscle complex following acute injury

    Energy Technology Data Exchange (ETDEWEB)

    Koulouris, George; Connell, David [Department of Radiology, St Francis X Cabrini, Wattletree Rd, 3144, Malvern, Victoria (Australia)

    2003-10-01

    To evaluate the imaging findings following acute hamstring injury. We retrospectively reviewed the imaging findings of hamstring muscle complex (HMC) strain in 170 patients referred to our institution over a 3-year period. A total of 179 injuries to the HMC were demonstrated in 170 patients (154 male, 16 female, mean age 28.2 years). The mean duration of symptoms was 4.7 days (range 1-10 days). MR imaging was performed in 97 cases and sonography in 102 cases (both modalities were performed in 20 examinations). Attention was directed to the frequency of muscle involvement, the location of the injury within the muscle-tendon unit, the extent of the injury and discriminating avulsion from muscle injury. Twenty-one patients had proximal tendon injury, with sixteen avulsions and five partial tears. Sixteen of these patients had surgical confirmation of hamstring avulsion from the ischial tuberosity (14 conjoint, 2 biceps femoris alone) and all were reliably diagnosed with MR imaging (16/16), but less so with sonography (7/12). Four distal tendon avulsions were also observed (three semitendinosus, one biceps femoris). With respect to muscle injury, the biceps femoris was most commonly injured (124/154). Semimembranosus was an uncommon muscle injury (21/154) and semitendinosus rare (9/154). Imaging can discriminate a hamstring tendon avulsion from musculotendinous strain and helps identify which patients necessitate surgical management as opposed to conservative treatment. (orig.)

  4. Passive Muscle-Tendon Unit Gearing is Joint Dependent in Human Medial Gastrocnemius

    Directory of Open Access Journals (Sweden)

    Emma F Hodson-Tole

    2016-03-01

    Full Text Available Skeletal muscles change length and develop force both passively and actively. Gearing allows muscle fibre length changes to be uncoupled from those of the whole muscle-tendon unit. During active contractions this process allows muscles to operate at mechanically favorable conditions for power or economical force production. Here we ask whether gearing is constant in passive muscle; determining the relationship between fascicle and muscle-tendon unit length change in the bi-articular medial gastrocnemius and investigating the influence of whether motion occurs at the knee or ankle joint. Specifically, the same muscle-tendon unit length changes were elicited by rotating either the ankle or knee joint whilst simultaneously measuring fascicle lengths in proximal and distal muscle regions using B-mode ultrasound. In both the proximal and distal muscle region, passive gearing values differed depending on whether ankle or knee motion occurred. Fascicle length changes were greater with ankle motion, likely reflecting anatomical differences in proximal and distal passive tendinous tissues, as well as shape changes of the adjacent mono-articular soleus. This suggests that there is joint-dependent dissociation between the mechanical behaviour of muscle fibres and the muscle-tendon unit during passive joint motions that may be important to consider when developing accurate models of bi-articular muscles.

  5. Distal finger replantation.

    Science.gov (United States)

    Scheker, Luis R; Becker, Giles W

    2011-03-01

    Reconstruction of the fingertip distal to the flexor tendon insertion by replantation remains controversial and technically challenging, but the anatomy of the fingertip has been well described and provides help in surgical planning. The open-book surgical technique is described with potential complications and is illustrated with clinical cases. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. A mini-invasive adductor magnus tendon transfer technique for medial patellofemoral ligament reconstruction: a technical note.

    Science.gov (United States)

    Sillanpää, Petri J; Mäenpää, Heikki M; Mattila, Ville M; Visuri, Tuomo; Pihlajamäki, Harri

    2009-05-01

    Patellar dislocations are associated with injuries to the medial patellofemoral ligament (MPFL). Several techniques for MPFL reconstruction have been recently published with some disadvantages involved, including large skin incisions and donor site morbidity. Arthroscopic stabilizing techniques carry the potential of inadequate restoration of MPFL function. We present a minimally invasive technique for MPFL reconstruction using adductor magnus tendon autograft. This technique is easily performed, safe, and provides a stabilizing effect equal to current MPFL reconstructions. Skin incision of only 3-4 cm is located at the level of the proximal half of the patella. After identifying the distal insertion of the adductor magnus tendon, a tendon harvester is introduced to harvest the medial two-thirds of the tendon, while the distal insertion is left intact. The adductor magnus tendon is cut at 12-14 cm from its distal insertion and transferred into the patellar medial margin. Two suture anchors are inserted through the same incision at the superomedial aspect of the patella in the anatomic MPFL origin. The graft is tightened at 30 degrees knee flexion. Aftercare includes 4 weeks of brace treatment with restricted range of motion.

  7. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    Science.gov (United States)

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  8. The anatomy and histology of the bicipital tunnel of the shoulder.

    Science.gov (United States)

    Taylor, Samuel A; Fabricant, Peter D; Bansal, Manjula; Khair, M Michael; McLawhorn, Alexander; DiCarlo, Edward F; Shorey, Mary; O'Brien, Stephen J

    2015-04-01

    The bicipital tunnel is the extra-articular, fibro-osseous structure that encloses the long head of the biceps tendon. Twelve cadaveric shoulder specimens underwent in situ casting of the bicipital tunnel with methyl methacrylate cement to demonstrate structural competence (n = 6) and en bloc harvest with gross and histologic evaluation (n = 6). The percentage of empty tunnel was calculated histologically by subtracting the proportion of cross-sectional area of the long head of the biceps tendon from that of the bicipital tunnel for each zone. Cement casting demonstrated that the bicipital tunnel was a closed space. Zone 1 extended from the articular margin to the distal margin of the subscapularis tendon. Zone 2 extended from the distal margin of the subscapularis tendon to the proximal margin of the pectoralis major tendon. Zone 3 was the subpectoral region. Zones 1 and 2 were both enclosed by a dense connective tissue sheath and demonstrated the presence of synovium. Zone 3 had significantly greater percentage of empty tunnel than zones 1 and 2 did (P < .01). The bicipital tunnel is a closed space with 3 distinct zones. Zones 1 and 2 have similar features, including the presence of synovium, but differ from zone 3. A significant bottleneck occurs between zone 2 and zone 3, most likely at the proximal margin of the pectoralis major tendon. The bicipital tunnel is a closed space where space-occupying lesions may produce a bicipital tunnel syndrome. Careful consideration should be given to surgical techniques that decompress both zones 1 and 2 of the bicipital tunnel. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  10. Segond fracture: involvement of the iliotibial band, anterolateral ligament, and anterior arm of the biceps femoris in knee trauma

    Energy Technology Data Exchange (ETDEWEB)

    Maeseneer, Michel de; Boulet, Cedric; Willekens, Inneke; Mey, Johan de; Shahabpour, Maryam [Universitair Ziekenhuis Brussel, Department of Radiology, Brussels (Belgium); Lenchik, Leon [Wake Forest University, Department of Radiology, Winston Salem, NC (United States); Cattrysse, Erik [Vrije Universiteit Brussel, Department of Experimental Anatomy, Brussels (Belgium)

    2014-12-04

    To evaluate the involvement of the iliotibial band (ITB), the anterolateral ligament (ALL), and the anterior arm of the biceps femoris in MRI-diagnosed Segond fracture and to evaluate other associated findings of Segond fracture. We retrospectively reviewed the MRI of 13 cases of Segond fracture. The studies included proton density-weighted, T2-weighted, and proton density-weighted with fat saturation images in the three planes. We studied 2 cadaveric specimens with emphasis on the ALL. One cadaveric specimen was dissected while the other was sectioned in the sagittal plane. The mean age of the patients was 36 years (range, 17-52). There were 7 men and 6 women. The mean size of the Segond bone fragment was 8 x 10 x 2 mm. The distance from the tibia varied from 2 to 6 mm. Associated findings included anterior cruciate ligament (ACL) tear (n = 13), medial collateral ligament (MCL) tear (n = 8), meniscocapsular tear of the posterior horn of the medial meniscus (n = 5), and posterolateral corner involvement (n = 4). Bone marrow edema involved the mid-lateral femoral condyle and the posterior tibial plateau on both the medial and the lateral side. Edema at the Segond area was seen, but was limited. Fibular head edema was also seen. The ITB (11 out of 13) and ALL (10 out of 13) inserted on the Segond bone fragment. The anterior arm of the biceps tendon did not insert on the Segond fracture. Associated findings of Segond fracture include ACL tear, MCL tear, medial meniscus tear, and posterolateral corner injury. Both the ITB and the ALL may be involved in the Segond avulsion. The anterior arm of the biceps femoris tendon is not involved. (orig.)

  11. Segond fracture: involvement of the iliotibial band, anterolateral ligament, and anterior arm of the biceps femoris in knee trauma

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Boulet, Cedric; Willekens, Inneke; Mey, Johan de; Shahabpour, Maryam; Lenchik, Leon; Cattrysse, Erik

    2015-01-01

    To evaluate the involvement of the iliotibial band (ITB), the anterolateral ligament (ALL), and the anterior arm of the biceps femoris in MRI-diagnosed Segond fracture and to evaluate other associated findings of Segond fracture. We retrospectively reviewed the MRI of 13 cases of Segond fracture. The studies included proton density-weighted, T2-weighted, and proton density-weighted with fat saturation images in the three planes. We studied 2 cadaveric specimens with emphasis on the ALL. One cadaveric specimen was dissected while the other was sectioned in the sagittal plane. The mean age of the patients was 36 years (range, 17-52). There were 7 men and 6 women. The mean size of the Segond bone fragment was 8 x 10 x 2 mm. The distance from the tibia varied from 2 to 6 mm. Associated findings included anterior cruciate ligament (ACL) tear (n = 13), medial collateral ligament (MCL) tear (n = 8), meniscocapsular tear of the posterior horn of the medial meniscus (n = 5), and posterolateral corner involvement (n = 4). Bone marrow edema involved the mid-lateral femoral condyle and the posterior tibial plateau on both the medial and the lateral side. Edema at the Segond area was seen, but was limited. Fibular head edema was also seen. The ITB (11 out of 13) and ALL (10 out of 13) inserted on the Segond bone fragment. The anterior arm of the biceps tendon did not insert on the Segond fracture. Associated findings of Segond fracture include ACL tear, MCL tear, medial meniscus tear, and posterolateral corner injury. Both the ITB and the ALL may be involved in the Segond avulsion. The anterior arm of the biceps femoris tendon is not involved. (orig.)

  12. Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienböck’s Disease: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Background. The optimal surgical treatment for Kienböck’s disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienböck’s disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.

  13. Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

    Science.gov (United States)

    Ayad, K. E.; El Gohary, H. M.; Abd Elrahman, M.; Abd El Mejeed, S. F.; Bekheet, A. B.

    2009-09-01

    Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) received low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.

  14. Giant Cell Tumour of the Distal Ulna: A Rare Presentation

    Directory of Open Access Journals (Sweden)

    Ruben Jaya Kumar

    2011-07-01

    Full Text Available Giant-cell tumour (GCT of bone, a primary yet locally aggressive benign tumour, commonly affects patients between the ages of 20 and 40 years, with the peak incidence occurring in the third decade. Women are affected slightly more than men. The distal end of the ulna is an extremely uncommon site for primary bone tumours in general and giant cell tumours in particular. Wide resection of the distal ulna is the recommended treatment for GCT in such locations. Radio-ulna convergence and dorsal displacement of the ulna stump are known complications following ulna resection proximal to the insertion of the pronator quadratus. This leads to reduction in grip power and forearm rotatory motion. Stabilization of the ulna stump with extensor carpi ulnaris (ECU tendon after wide resection of the tumour has been described in the literature. We report a case of GCT of distal end of ulna treated with wide resection and stabilization with ECU tendon.

  15. Rehabilitation of the elbow extension with motor imagery in a patient with quadriplegia after tendon transfer.

    Science.gov (United States)

    Grangeon, Murielle; Guillot, Aymeric; Sancho, Pierre-Olivier; Picot, Marion; Revol, Patrice; Rode, Gilles; Collet, Christian

    2010-07-01

    To test the effect of a postsurgical motor imagery program in the rehabilitation of a patient with quadriplegia. Crossover design with kinematic analysis. Rehabilitation Hospital of Lyon. Study approved by the local Human Research Ethics Committee. C6-level injured patient (American Spinal Injury Association Impairment Scale grade A) with no voluntary elbow extension (triceps brachialis score 1). The surgical procedure was to transfer the distal insertion of the biceps brachii onto the triceps tendon of both arms. The postsurgical intervention on the left arm included 10 sessions of physical rehabilitation followed by 10 motor imagery sessions of 30 minutes each. The patient underwent 5 sessions a week during 2 consecutive weeks. The motor imagery content included mental representations based on elbow extension involved in goal-directed movements. The rehabilitation period of the right arm was reversed, with motor imagery performed first, followed by physical therapy. The kinematics of upper-limb movements was recorded (movement time and variability) before and after each type of rehabilitation period. A long-term retention test was performed 1 month later. Motor imagery training enhanced motor recovery by reducing hand trajectory variability-that is, improving smoothness. Motor performance then remained stable over 1 month. Motor imagery improved motor recovery when associated with physical therapy, with motor performance remaining stable over the 1-month period. We concluded that motor imagery should be successfully associated with classic rehabilitation procedure after tendon transfer. Physical sessions may thus be shortened if too stressful or painful. Copyright 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Young [Dept. of Radiology, Saint Paul' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of); Yoon, Young Cheol; Cha, Dong Ik [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ, School of Medicine, Seoul (Korea, Republic of)], e-mail: ycyoon@skku.edu; Yoo, Jae-Chul [Dept. of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Jung, Jee Young [Dept. of Radiology, School of Medicine, Chung-Ang Univ., Seoul (Korea, Republic of)

    2013-02-15

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of

  17. Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.

    Science.gov (United States)

    Luchetti, R; Atzei, A

    2017-05-01

    We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.

  18. Region specific patella tendon hypertrophy in humans following resistance training

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Reitelseder, S; Pedersen, T.G.

    2007-01-01

    AIM: To examine if cross-sectional area (CSA) differs along the length of the human patellar tendon (PT), and if there is PT hypertrophy in response to resistance training. METHODS: Twelve healthy young men underwent baseline and post-training assessments. Maximal isometric knee extension strength...... (MVC) was determined unilaterally in both legs. PT CSA was measured at the proximal-, mid- and distal PT level and quadriceps muscle CSA was measured at mid-thigh level using magnetic resonance imaging. Mechanical properties of the patellar tendons were determined using ultrasonography. Subsequently....... CONCLUSIONS: To our knowledge, this study is the first to report tendon hypertrophy following resistance training. Further, the data show that the human PT CSA varies along the length of the tendon....

  19. Effect of Basic Fibroblast Growth Factor on Achilles Tendon Healing in Rabbit.

    Science.gov (United States)

    Najafbeygi, Arash; Fatemi, Mohammad Javad; Lebaschi, Amir Hussein; Mousavi, Seyed Jaber; Husseini, Seyed Abouzar; Niazi, Mitra

    2017-01-01

    Tendon injuries are common and it takes a long time for an injured tendon to heal. Adverse phenomena such as adhesion and rupture are associated with these injuries. Finding a method to reduce the time required for healing which improves the final outcome, will lead to decreased frequency and intensity of adverse consequences. This study was designed to investigate the effects of basic fibroblast growth factor on the healing of the Achilles tendon in rabbits. In 10 New Zealand white rabbits, Achilles tendon was cut at the intersection of the distal and middle thirds on both hind legs. One microgram of recombinant basic fibroblast growth factor (bFGF) was injected in the proximal and distal stumps of the cut tendon on the right side (study group). Normal saline of equal volume was injected on the left side in the same way (control group). Then the tendons were repaired with 5/0 nylon using modified Kessler technique. A cast was made to immobilize each leg. On day 42, rabbits were euthanized and both hind legs were amputated. Tensometry and histopathologic examination were done on specimens. In tensometric studies, more force was required to rupture the repair site in study group. In histopathologic examination, collagen fibers had significantly better orientation and organization in the study group. No difference was noted regarding number of fibroblast and fibrocytes, and degree of angiogenesis in the two groups. Application of basic fibroblast growth factor at tendon repair site improves the healing process through improvement of collagen fiber orientation and increase in biomechanical resistance.

  20. Coracoclavicular ligament reconstruction with the autogenous anterior half of the peroneus longus tendon for distal clavicle fracture (Neer type Ⅱ-b: A report of 26 cases

    Directory of Open Access Journals (Sweden)

    Guang-you YANG

    2017-12-01

    Full Text Available Objective To explore the clinical effect of coracoclavicular ligament reconstruction with the autogenous anterior half of peroneus longus tendon (AHPLT for distal clavicle fracture (Neer type Ⅱ-b. Methods The clinical data were retrospectively analyzed of 26 Neer type Ⅱ-b distal clavicle fracture surgically treated by coracoclavicular ligament reconstruction with autogenous AHPLT in Ganyu District People's Hospital of Lianyungang from June 2012 to May 2015. Among the 26 cases, 16 males and 10 females, aged from 19-56 years (average 38.7 years. Fracture occurred in left side in 18 cases and in right side in 8 cases. Postoperative observations were done on fracture healing, shoulder and ankle-foot function recovery. Results For all the 26 cases, surgical incisions were healed well, and no infection, vascular and peroneal nerve injury and iatrogenic fracture occurred. Follow-up was carried out for 10-24 months with average of 15.3 months. All the fractures were healed within 12-20 weeks with an average of 14.6 weeks. One patient was found of losing the fracture reduction part during the follow-up process, and then got eventual healing by extending the limb brake time. Another patient was found of slight tendon sensation disorder with no significant effect on daily life and exercise, and the symptoms disappeared 6 months later. At the last follow-up, the Constant-Murley score was 92-100 with an average of 97.8 points. The ankle-hind foot score of American Society of Ankle and Orthopedics was excellent. Conclusion Reconstruction of coracoclavicular ligament with autogenous AHPLT is an effective treatment for Neer type Ⅱ-b distal clavicle fracture with good safety and without negative effect on the ankle-foot function, and thus it is worthy of wider clinical use. DOI: 10.11855/j.issn.0577-7402.2017.12.12

  1. Attrition tendinitis of long head of biceps brachii in relation to humeral head osteonecrosis: case report.

    Science.gov (United States)

    Wiesler, Ethan R; Sarlikiotis, Thomas; Mavrogenis, Andreas F; Kokkalis, Zinon T

    2013-01-01

    This case report identifies a 41-year-old male patient who developed anterior shoulder pain in the setting of humeral head osteonecrosis. As a consequence of the cartilage degeneration, multiple loose bodies formed and migrated into the bicipital tendon sheath, causing attrition tendinitis, which was a feature of the clinical presentation. The patient was treated by a combination of arthroscopic glenohumeral joint debridement and open tenodesis of the biceps using a suture anchor. Follow-up revealed asymptomatic shoulder function by 18 months. This is the first report in the literature of bicipital tendinitis in the context of avascular necrosis of the shoulder.

  2. Distal intersection tenosynovitis of the wrist: a lesser-known extensor tendinopathy with characteristic MR imaging features

    International Nuclear Information System (INIS)

    Parellada, Antoni J.; Gopez, Angela G.; Morrison, William B.; Sweet, Stephanie; Leinberry, Charles F.; Reiter, Sean B.; Kohn, Mark

    2007-01-01

    To present the MRI imaging findings of extensor tenosynovitis at the distal intersection or crossover between the second (extensor carpi radialis longus (ECRL) and brevis (ECRB)) and third (extensor pollicis longus (EPL)) extensor compartment tendons, and the anatomical details that may play a role in the pathogenesis of this condition. The imaging studies and clinical records of five patients (three females and two males, with ages ranging between 22 and 78 years; mean age, 49 years) presenting with pain on the dorsal and radial aspect of the wrist were reviewed by two musculoskeletal radiologists in consensus. Three cases were identified serendipitously during routine clinical reading sessions; a follow-up computerized database search for additional cases reported in the prior two years yielded two additional cases. The overall number of cases screened was 1,031. The diagnosis of tendinopathy affecting the second and third compartment extensor tendons was made on the basis of MRI findings and clinical follow-up, or synovectomy. All patients showed signs of tenosynovitis: in four patients both the tendons of the second and third extensor compartments were affected; the fifth patient showed signs of tenosynovitis of the EPL tendon, and tendinosis of the extensor carpi radialis tendons. Three patients showed tenosynovitis proximal and distal to the point of intersection; and in two of them, a discrete point of constriction was appreciated at the crossover site in relation to the extensor retinaculum. Two patients showed tenosynovitis limited to the segment distal to the point of decussation. Tendinosis tended to follow the presence of tenosynovitis. In one of the patients, subtendinous reactive marrow edema in Lister's tubercle was noted. Distal intersection tenosynovitis may be related to the biomechanical pulley effect exerted by Lister's tubercle on the EPL tendon as it leaves the third compartment and crosses over the extensor carpi radialis tendons, as well as

  3. Distal intersection tenosynovitis of the wrist: a lesser-known extensor tendinopathy with characteristic MR imaging features

    Energy Technology Data Exchange (ETDEWEB)

    Parellada, Antoni J. [DII - Diagnostic Imaging, Inc., Philadelphia, PA (United States); Frankford Hospitals - Torresdale Campus, Department of Radiology, Philadelphia, PA (United States); Gopez, Angela G.; Morrison, William B. [Thomas Jefferson University, Department of Radiology, Philadelphia, PA (United States); Sweet, Stephanie [Thomas Jefferson University, Philadelphia Hand Center, Philadelphia, PA (United States); Leinberry, Charles F. [Thomas Jefferson University, Department of Orthopedic Surgery - Hand Surgery, Philadelphia, PA (United States); Reiter, Sean B.; Kohn, Mark [DII - Diagnostic Imaging, Inc., Philadelphia, PA (United States)

    2007-03-15

    To present the MRI imaging findings of extensor tenosynovitis at the distal intersection or crossover between the second (extensor carpi radialis longus (ECRL) and brevis (ECRB)) and third (extensor pollicis longus (EPL)) extensor compartment tendons, and the anatomical details that may play a role in the pathogenesis of this condition. The imaging studies and clinical records of five patients (three females and two males, with ages ranging between 22 and 78 years; mean age, 49 years) presenting with pain on the dorsal and radial aspect of the wrist were reviewed by two musculoskeletal radiologists in consensus. Three cases were identified serendipitously during routine clinical reading sessions; a follow-up computerized database search for additional cases reported in the prior two years yielded two additional cases. The overall number of cases screened was 1,031. The diagnosis of tendinopathy affecting the second and third compartment extensor tendons was made on the basis of MRI findings and clinical follow-up, or synovectomy. All patients showed signs of tenosynovitis: in four patients both the tendons of the second and third extensor compartments were affected; the fifth patient showed signs of tenosynovitis of the EPL tendon, and tendinosis of the extensor carpi radialis tendons. Three patients showed tenosynovitis proximal and distal to the point of intersection; and in two of them, a discrete point of constriction was appreciated at the crossover site in relation to the extensor retinaculum. Two patients showed tenosynovitis limited to the segment distal to the point of decussation. Tendinosis tended to follow the presence of tenosynovitis. In one of the patients, subtendinous reactive marrow edema in Lister's tubercle was noted. Distal intersection tenosynovitis may be related to the biomechanical pulley effect exerted by Lister's tubercle on the EPL tendon as it leaves the third compartment and crosses over the extensor carpi radialis tendons

  4. Upper extremity weightlifting injuries: Diagnosis and management.

    Science.gov (United States)

    Golshani, Kayvon; Cinque, Mark E; O'Halloran, Peter; Softness, Kenneth; Keeling, Laura; Macdonell, J Ryan

    2018-03-01

    Common upper extremity injuries in resistance training athletes include muscle strains, ligament sprains, pectoralis major tendon ruptures, distal biceps tendon ruptures, and chronic shoulder pain and capsulolabral injuries. While each injury is unique in its specific anatomic location and mechanism, each is preventable with proper exercise technique, safety and maintenance of muscle balance. Conservative treatment is the therapeutic modality of choice and these injuries generally resolve with workout modification, appropriate recovery, anti-inflammatory medication, and physical therapy. If conservative treatment fails, surgical intervention is often successful and can return the weightlifter to a level of performance near their pre-injury level.

  5. Ossifying tendinitis of the rotator cuff after arthroscopic excision of calcium deposits: report of two cases and literature review.

    Science.gov (United States)

    Merolla, Giovanni; Dave, Arpit C; Paladini, Paolo; Campi, Fabrizio; Porcellini, Giuseppe

    2015-03-01

    Ossifying tendinitis (OT) is a type of heterotopic ossification, characterized by deposition of hydroxyapatite crystals in a histologic pattern of mature lamellar bone. It is usually associated with surgical intervention or trauma and is more commonly seen in Achilles or distal biceps tendons, and also in the gluteus maximus tendon. To our knowledge, there is no description of OT as a complication of calcifying tendinitis of the rotator cuff. In this report, we describe two cases in which the patients developed an OT of the supraspinatus after arthroscopic removal of calcium deposits. The related literature is reviewed.

  6. The energetic benefits of tendon springs in running: is the reduction of muscle work important?

    Science.gov (United States)

    Holt, Natalie C; Roberts, Thomas J; Askew, Graham N

    2014-12-15

    The distal muscle-tendon units of cursorial species are commonly composed of short muscle fibres and long, compliant tendons. It is assumed that the ability of these tendons to store and return mechanical energy over the course of a stride, thus avoiding the cyclic absorption and regeneration of mechanical energy by active muscle, offers some metabolic energy savings during running. However, this assumption has not been tested directly. We used muscle ergometry and myothermic measurements to determine the cost of force production in muscles acting isometrically, as they could if mechanical energy was stored and returned by tendon, and undergoing active stretch-shorten cycles, as they would if mechanical energy was absorbed and regenerated by muscle. We found no detectable difference in the cost of force production in isometric cycles compared with stretch-shorten cycles. This result suggests that replacing muscle stretch-shorten work with tendon elastic energy storage and recovery does not reduce the cost of force production. This calls into question the assumption that reduction of muscle work drove the evolution of long distal tendons. We propose that the energetic benefits of tendons are derived primarily from their effect on muscle and limb architecture rather than their ability to reduce the cyclic work of muscle. © 2014. Published by The Company of Biologists Ltd.

  7. Contribution of full-thickness supraspinatus tendon tears to acquired subcoracoid impingement

    Energy Technology Data Exchange (ETDEWEB)

    MacMahon, P.J. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland)]. E-mail: petermacmahon@yahoo.com; Taylor, D.H. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); Duke, D. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); Brennan, D.D. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); O' Brien, J. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland); Eustace, S.J. [Department of Radiology, Cappagh National Orthopaedic Hospital, Finglas, Dublin (Ireland)

    2007-06-15

    Aim: To assess the relationship between the severity of full-thickness supraspinatus tendon tears and the development of subcoracoid impingement. Materials and methods: Fifty-one magnetic resonance imaging (MRI) shoulder examination reports with full-thickness supraspinatus tears were retrospectively identified and reviewed by two dedicated musculoskeletal radiologists. The appearances of the rotator cuff muscles, biceps tendon and the lesser tubercle were recorded. The acromio-humeral distance and the axial coraco-humeral distance were measured. The data were recorded and analysed electronically. Results: The kappa values for inter-observer agreement were: 0.91 for acromio-humeral distance and 0.85 for coraco-humeral distance measurements. Twenty-six patients had significant retraction of the supraspinatus tendon, 85% (22 cases) of this group had imaging evidence of tear or tendonopathy of the subscapularis tendon. Twenty-five patients had no significant retraction of the supraspinatus, 56% (14 cases) of this group had imaging evidence of a subscapularis tear or tendonopathy. The acromio-humeral distance was significantly less in patients with supraspinatus tears and retraction (p < 0.05). The subscapularis tendon was significantly more likely to be abnormal if the supraspinatus was retracted than if no retraction was present (p < 0.05). There were no significant differences in coraco-humeral distances between the groups. Conclusion: Subscapularis tendon signal and structural changes are frequently associated with full-thickness supraspinatus tendon tears, particularly if the supraspinatus is significantly retracted. In this static MRI series, the data do not support the occurrence of classical subcoracoid impingement as an aetiology; however, they may support the possibility of a dynamic mechanism, to which future studies could be directed.

  8. Contribution of full-thickness supraspinatus tendon tears to acquired subcoracoid impingement

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Taylor, D.H.; Duke, D.; Brennan, D.D.; O'Brien, J.; Eustace, S.J.

    2007-01-01

    Aim: To assess the relationship between the severity of full-thickness supraspinatus tendon tears and the development of subcoracoid impingement. Materials and methods: Fifty-one magnetic resonance imaging (MRI) shoulder examination reports with full-thickness supraspinatus tears were retrospectively identified and reviewed by two dedicated musculoskeletal radiologists. The appearances of the rotator cuff muscles, biceps tendon and the lesser tubercle were recorded. The acromio-humeral distance and the axial coraco-humeral distance were measured. The data were recorded and analysed electronically. Results: The kappa values for inter-observer agreement were: 0.91 for acromio-humeral distance and 0.85 for coraco-humeral distance measurements. Twenty-six patients had significant retraction of the supraspinatus tendon, 85% (22 cases) of this group had imaging evidence of tear or tendonopathy of the subscapularis tendon. Twenty-five patients had no significant retraction of the supraspinatus, 56% (14 cases) of this group had imaging evidence of a subscapularis tear or tendonopathy. The acromio-humeral distance was significantly less in patients with supraspinatus tears and retraction (p < 0.05). The subscapularis tendon was significantly more likely to be abnormal if the supraspinatus was retracted than if no retraction was present (p < 0.05). There were no significant differences in coraco-humeral distances between the groups. Conclusion: Subscapularis tendon signal and structural changes are frequently associated with full-thickness supraspinatus tendon tears, particularly if the supraspinatus is significantly retracted. In this static MRI series, the data do not support the occurrence of classical subcoracoid impingement as an aetiology; however, they may support the possibility of a dynamic mechanism, to which future studies could be directed

  9. Novel fiber-based pure chitosan scaffold for tendon augmentation: biomechanical and cell biological evaluation.

    Science.gov (United States)

    Nowotny, J; Aibibu, D; Farack, J; Nimtschke, U; Hild, M; Gelinsky, M; Kasten, P; Cherif, Ch

    2016-07-01

    One possibility to improve the mechanical properties after tendon ruptures is augmentation with a scaffold. Based on wet spinning technology, chitosan fibres were processed to a novel pure high-grade multifilament yarn with reproducible quality. The fibres were braided to obtain a 3D tendon scaffold. The CS fibres and scaffolds were evaluated biomechanically and compared to human supraspinatus (SSP) tendons. For the cytobiological characterization, in vitro cell culture experiments with human mesenchymal stem cells (hMSC) were performed. Three types of 3D circular braided scaffolds were fabricated. Significantly, higher ultimate stress values were measured for scaffold with larger filament yarn, compared to scaffold with smaller filament yarn. During cultivation over 28 days, the cells showed in dependence of isolation method and/or donor a doubling or tripling of the cell number or even a six-fold increase on the CS scaffold, which was comparable to the control (polystyrene) or in the case of cells obtained from human biceps tendon even higher proliferation rates. After 14 days, the scaffold surface was covered homogeneously with a cell layer. In summary, the present work demonstrates that braided chitosan scaffolds constitute a straightforward approach for designing tendon analogues, maintaining important flexibility in scaffold design and providing favourable mechanical properties of the resulting construct.

  10. The distal semimembranosus complex: normal MR anatomy, variants, biomechanics and pathology

    International Nuclear Information System (INIS)

    Beltran, Javier; Jbara, Marlena; Maimon, Ron; Matityahu, Amir; Hwang, Ki; Padron, Mario; Mota, Javier; Beltran, Luis; Sundaram, Murali

    2003-01-01

    To describe the normal MR anatomy and variations of the distal semimembranosus tendinous arms and the posterior oblique ligament as seen in the three orthogonal planes, to review the biomechanics of this complex and to illustrate pathologic examples. The distal semimembranosus tendon divides into five tendinous arms named the anterior, direct, capsular, inferior and the oblique popliteal ligament. These arms intertwine with the branches of the posterior oblique ligament in the posterior medial aspect of the knee, providing stability. This tendon-ligamentous complex also acts synergistically with the popliteus muscle and actively pulls the posterior horn of the medial meniscus during knee flexion. Pathologic conditions involving this complex include complete and partial tears, insertional tendinosis, avulsion fractures and bursitis. (orig.)

  11. The distal semimembranosus complex: normal MR anatomy, variants, biomechanics and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, Javier; Jbara, Marlena; Maimon, Ron [Department of Radiology, Maimonides Medical Center, 4802 Tenth Avenue, NY 11219, Brooklyn (United States); Matityahu, Amir; Hwang, Ki [Department of Orthopedic Surgery, Maimonides Medical Center, Brooklyn, NY (United States); Padron, Mario [Department of Radiology, Clinica CEMTRO, Madrid (Spain); Mota, Javier [Department of Radiology, Instituto Clinica Corachan, Barcelona (Spain); Beltran, Luis [New York Medical College, Valhalla, NY (United States); Sundaram, Murali [Department of Radiology, Mayo Clinic, Rochester, MN (United States)

    2003-08-01

    To describe the normal MR anatomy and variations of the distal semimembranosus tendinous arms and the posterior oblique ligament as seen in the three orthogonal planes, to review the biomechanics of this complex and to illustrate pathologic examples. The distal semimembranosus tendon divides into five tendinous arms named the anterior, direct, capsular, inferior and the oblique popliteal ligament. These arms intertwine with the branches of the posterior oblique ligament in the posterior medial aspect of the knee, providing stability. This tendon-ligamentous complex also acts synergistically with the popliteus muscle and actively pulls the posterior horn of the medial meniscus during knee flexion. Pathologic conditions involving this complex include complete and partial tears, insertional tendinosis, avulsion fractures and bursitis. (orig.)

  12. MRI findings in Kirner deformity: normal insertion of the flexor digitorum profundus tendon without soft-tissue enhancement

    International Nuclear Information System (INIS)

    Lee, Jaejoon; Ahn, Joong Kyong; Koh, Eun-Mi; Cha, Hoon-Suk; Choi, Sang-Hee

    2010-01-01

    Kirner deformity is characterized by volar and radial incurvature of the distal phalanx of the 5th finger. A proposed causative mechanism includes abnormal distal insertion of the flexor digitorum profundus tendon along the volar surface of the distal phalanx of the 5th finger. A chronic inflammatory process or altered vascularisation of the soft tissues has also been suggested as the underlying causative mechanism based on MRI findings. We present a teenage boy with Kirner deformity, along with supplementary imaging of his father who also has the deformity, to illustrate MRI findings that dispute the above hypotheses. MRI in both son and father show normal insertion of the deep flexor tendon and no signs of inflammation. (orig.)

  13. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  14. Regional molecular and cellular differences in the female rabbit Achilles tendon complex: potential implications for understanding responses to loading.

    Science.gov (United States)

    Huisman, Elise S; Andersson, Gustav; Scott, Alexander; Reno, Carol R; Hart, David A; Thornton, Gail M

    2014-05-01

    The aim of this study was: (i) to analyze the morphology and expression of extracellular matrix genes in six different regions of the Achilles tendon complex of intact normal rabbits; and (ii) to assess the effect of ovariohysterectomy (OVH) on the regional expression of these genes. Female New Zealand White rabbits were separated into two groups: (i) intact normal rabbits (n = 4); and (ii) OVH rabbits (n = 8). For each rabbit, the Achilles tendon complex was dissected into six regions: distal gastrocnemius (DG); distal flexor digitorum superficialis; proximal lateral gastrocnemius (PLG); proximal medial gastrocnemius; proximal flexor digitorum superficialis; and paratenon. For each of the regions, hematoxylin and eosin staining was performed for histological evaluation of intact normal rabbit tissues and mRNA levels for proteoglycans, collagens and genes associated with collagen regulation were assessed by real-time reverse transcription-quantitative polymerase chain reaction for both the intact normal and OVH rabbit tissues. The distal regions displayed a more fibrocartilaginous phenotype. For intact normal rabbits, aggrecan mRNA expression was higher in the distal regions of the Achilles tendon complex compared with the proximal regions. Collagen Type I and matrix metalloproteinase-2 expression levels were increased in the PLG compared to the DG in the intact normal rabbit tissues. The tendons from OVH rabbits had lower gene expressions for the proteoglycans aggrecan, biglycan, decorin and versican compared with the intact normal rabbits, although the regional differences of increased aggrecan expression in distal regions compared with proximal regions persisted. The tensile and compressive forces experienced in the examined regions may be related to the regional differences found in gene expression. The lower mRNA expression of the genes examined in the OVH group confirms a potential effect of systemic estrogen on tendon. © 2014 Anatomical Society.

  15. Ultrasonographic Tendon Alteration in Relation to Parathyroid Dysfunction in Chronic Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Dahlia A. Hussein

    2015-01-01

    Full Text Available Objective To find the nature of tendon involvement in chronic kidney disease (CKD patients on regular hemodialysis (RD, and its relationship to parathyroid hormone (PTH level using ultrasonography (US. Method A total of 50 CKD patients on RD subjected to musculoskeletal examination of knee and ankle, laboratory evaluation, and US of quadriceps tendon and Achilles tendon were involved. Results Ankle joint tenderness was the most frequent sign on examination. US of the Achilles tendons showed tenderness during probing in 44% patients, calcific deposition in 24% patients, abnormal peritendon tissue in 20% patients, and abnormal anteroposterior (A-P middle and distal one-third thicknesses of the Achilles tendon in 20% and 18% patients, respectively. PTH positively correlated with the duration of dialysis, serum phosphorus level, presence of calcific deposit, and increased thickness of the Achilles tendon. Conclusion The most common ultrasonographic finding in CKD patients on RD was Achilles tendon tenderness during probing. PTH level positively correlated with the duration of dialysis, presence of calcific deposit, and increased thickness of Achilles tendon.

  16. MR anatomy study of the elbow, with emphasis in ligaments and tendons structure - methodology

    International Nuclear Information System (INIS)

    Vilela, Sonia de Aguiar; Fernandes, Artur da Rocha Correa; Barbieri, Antonio; Turrini, Elisabete; Juliano, Yara

    1999-01-01

    Seventeen MR exams of the elbow joints of fifteen healthy volunteers were obtained on T1 spin-echo sequences in the transversal, coronal and sagital planes. Eight anatomic structures were selected and evaluated by three independent blind readers. The aim of this study was to establish the frequency of visibility as well to determine the best plane to characterize these anatomic structures and also to analyze the interobserver variability. The readers analyzed the exams using the same criteria: degree 0 (structure not visible); degree 1 (structure visible and partially delineated); degree 2 (structure well visible and well delineated). The structure visibility showed variability close related to the degree (1 or 2) chosen by the readers to define the structure visualization and mainly in the transverse plane. The coronal plane was showed to be the ideal to evaluate the collateral ligaments, the common extensor tendon and the com,mon flexor tendon, otherwise the sagital plane was useful to define triceps and braquial tendons. The biceps tendon and annular ligament were well defined in the transverse plane. The usefulness of this study is to establish the ideal planes to evaluate these anatomic structures, and develop faster protocols. (author)

  17. Evaluation of the results from arthroscopic tenodesis of the long head of the biceps brachii on the tendon of the subscapularis muscle

    Directory of Open Access Journals (Sweden)

    Marcelo Baggio

    2016-04-01

    Full Text Available OBJECTIVES: The aim of this study was to evaluate the results from arthroscopic tenodesis of the long head of the biceps brachii (LHBB on the tendon of the subscapularis muscle, with regard to the presence of pain, subscapularis lesion, presence of Popeye's sign and patient satisfaction. METHODS: A prospective cohort study was conducted on 32 patients with LHBB lesions, through preoperative interviews and physical examinations, which were repeated six months after the operation. The main variables studied were the belly press, bear hug and lift-off tests, Popeye's sign, anterior pain and satisfaction. The data were entered into Epi Info 3.5.4 and SPSS 18.0. In order to investigate the variables of interest, the chi-square, Student t and Kruskal-Wallis tests were used. The confidence interval was 95% and p values less than 0.05 were taken to be statistically significant. RESULTS: 32 patients of median age 57.5 years were evaluated. Anterior pain was reported by one interviewee after the operation. The tests for evaluating subscapularis lesions did not show any damage to this musculature after the surgery. Popeye's sign was negative in all the patients. The patient satisfaction rate reached 90.6% of the interviewees. CONCLUSION: This study showed that the new surgical technique described here presented excellent performance, without any subscapularis lesion and without identifying Popeye's sign. Only 3.1% of the patients had complaints of residual pain. The high level of satisfaction among the patients after the surgery confirms the results presented.

  18. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  19. Distal triceps injuries (including snapping triceps): A systematic review of the literature.

    Science.gov (United States)

    Shuttlewood, Kimberley; Beazley, James; Smith, Christopher D

    2017-06-18

    To review current literature on types of distal triceps injury and determine diagnosis and appropriate management. We performed a systematic review in PubMed, Cochrane and EMBASE using the terms distal triceps tears and snapping triceps on the 10 th January 2017. We excluded all animal, review, foreign language and repeat papers. We reviewed all papers for relevance and of the papers left we were able to establish the types of distal triceps injury, how these injuries are diagnosed and investigated and the types of management of these injuries including surgical. The results are then presented in a review paper format. Three hundred and seventy-nine papers were identified of which 65 were relevant to distal triceps injuries. After exclusion we had 47 appropriate papers. The papers highlighted 2 main distal triceps injuries: Distal triceps tears and snapping triceps. Triceps tear are more common in males than females occurring in the 4 th -5 th decade of life and often due to a direct trauma but are also strongly associated with weightlifting and American football. The tears are diagnosed by history and clinically with a palpable gap. Diagnosis can be confirmed with the use of ultrasound (US) and magnetic resonance imaging. Treatment depends on type of tear. Partial tears can be treated conservatively with bracing and physio whereas acute tears need repair either open or arthroscopic using suture anchor or bone tunnel techniques with similar success. Chronic tears often need augmenting with tendon allograft or autograft. Snapping triceps are also seen more in men than women but at a mean age of 32 years. They are characterized by a snapping sensation mostly medially and can be associated with ulna nerve subluxation and ulna nerve symptoms. US is the diagnostic modality of choice due to its dynamic nature and to differentiate between snapping triceps tendon or ulna nerve. Treatment is conservative initially with activity avoidance and if that fails surgical

  20. Prolonged passive static stretching-induced innervation zone shift in biceps brachii.

    Science.gov (United States)

    Ye, Xin; Beck, Travis W; Wages, Nathan P

    2015-05-01

    The purpose of this study was to examine the influence of a bout of repeated and prolonged passive static stretching on the innervation zone (IZ) location of the human biceps brachii muscle. Eleven men performed 12 sets of 100-s passive stretches on their biceps brachii. Before (Pre) and immediately after (Post) the stretching intervention, isometric strength was tested during the maximal voluntary contractions (MVCs) of the forearm flexors. The subjects also performed several separate isometric forearm flexion muscle actions at 30%, 50%, and 70% of their predetermined MVCs for examining the locations of the IZ at different contraction intensities. The IZ was identified through multi-channel surface electromyographic (EMG) recordings from a linear electrode array. The stretching intervention induced an average of 10% isometric strength loss for the forearm flexors (mean±SD: Pre-MVC vs. Post-MVC=332.12±59.40 N vs. 299.53±70.51 N; p<0.001). In addition, the average IZ shift was nearly 4.5 mm in average in the proximal direction. However, this shift was not specific to the contraction intensity. We believe that the IZ shift was caused by the elongation of the entire muscle-tendon unit in the proximal direction. Therefore, caution should be taken when using surface EMG technique to examine possible changes in the EMG variables after a stretching protocol, as these variables can be contaminated by the shift of the IZ.

  1. Effect of patient age on accuracy of primary MRI signs of long head of biceps tearing and instability in the shoulder. An MRI-arthroscopy correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Borrero, Camilo G.; Costello, Joanna; Vyas, Dharmesh [University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Bertolet, Marnie [University of Pittsburgh School of Medicine, Pittsburgh, PA (United States)

    2018-02-15

    To determine the effect of patient age on the accuracy of primary MRI signs of long head of biceps (LHB) tendon tearing and instability in the shoulder using arthroscopy as a reference standard. Subjects with MRI studies and subsequent arthroscopy documenting LHB tendon pathology were identified and organized into three age groups (18-40, 41-60, 61-87). Normal and tendinopathic tendons were labeled grade 0, partial tears grade 1 and full tears grade 2. Two radiologists blinded to arthroscopic data graded MRI studies independently. Prevalence of disease, MRI accuracy for outcomes of interest, and inter-reader agreement were calculated. Eighty-nine subjects fulfilled inclusion criteria with 36 grade 0, 36 grade 1 and 17 grade 2 tendons found at arthroscopy. MRI sensitivity, regardless of age, ranged between 67-86% for grade 0, 72-94% for grade 1 and 82-94% for grade 2 tendons. Specificity ranged between 83-96% for grade 0, 75-85% for grade 1 and 99-100% for grade 2 tendons. MRI accuracy for detection of each LHB category was calculated for each age group. MRI was found to be least sensitive for grade 0 and 1 LHB tendons in the middle-aged group with sensitivity between 55-85% for grade 0 and 53-88% for grade 1 tendons. Agreement between MRI readers was moderate with an unweighted kappa statistic of 62%. MRI accuracy was moderate to excellent and agreement between MRI readers was moderate. MRI appears to be less accurate in characterizing lower grades of LHB tendon disease in middle-aged subjects. (orig.)

  2. Spontaneous Extensor Tendon Rupture in the Rheumatoid Wrist: Risk Factors and Preventive Role of Extended Tenosynovectomy.

    Science.gov (United States)

    Hsueh, Jung-Hua; Liu, Wen-Chung; Yang, Kuo-Chung; Hsu, Kuei-Chang; Lin, Cheng-Ta; Chen, Lee-Wei

    2016-03-01

    Spontaneous extensor tendon rupture is often seen in rheumatoid arthritis (RA) patients, but the risk factors are not clearly defined. We therefore collected the data of RA patients with previous extensor tendon rupture and those with tenosynovitis and analyzed the relationship between extended tenosynovectomy and spontaneous extensor tendon rupture. We retrospectively reviewed 17 spontaneous extensor tendon rupture episodes in 15 RA patients and 14 tenosynovitis episodes that required tenosynovectomy in 12 RA patients from 1997 to 2013. Correlations between the incidence of tendon rupture, X-ray findings, and clinical findings in the affected wrists before tendon rupture were analyzed statistically using the test for proportion. The following parameters were significantly correlated with spontaneous extensor tendon rupture: disease duration longer than 8 years, persistent tenosynovitis longer than 1 year duration, and Larsen grade greater than 4 (P = 0.02, 0.03, and 0.01, respectively). Dislocation of the distal end of the ulna, carpal collapse, and the scallop sign on X-ray contributed to a higher spontaneous extensor tendon rupture rate among RA patients (P = 0.01, 0.05, and 0.03, respectively). Extended tenosynovectomy was performed on 14 wrists in 12 RA patients with persistent tenosynovitis longer than 6 months, and Larsen grade did not deteriorate in this group compared with those who did not undergo the surgery. No spontaneous extensor tendon rupture occurred following the surgery. Risk factors of spontaneous extensor tendon rupture included disease duration longer than 8 years, persistent tenosynovitis longer than 1 year, and wrist Larsen grade greater than 4. Dislocation of the distal end of the ulna, carpal collapse, and the scallop sign on X-ray indicated a higher probability of extensor tendon rupture. Rheumatologists should consult with hand surgeons promptly to preserve hand function before tendon rupture. Prophylactic extended tenosynovectomy

  3. MR imaging of delamination tears of the rotator cuff tendons

    International Nuclear Information System (INIS)

    Walz, Daniel M.; Chen, Steven; Miller, Theodore T.; Hofman, Josh

    2007-01-01

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  4. MR imaging of delamination tears of the rotator cuff tendons

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Daniel M.; Chen, Steven [North Shore University Hospital, Department of Radiology, Manhasset, NY (United States); Miller, Theodore T. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States); Hofman, Josh [Long Island Jewish Medical Center, New Hyde Park, NY (United States)

    2007-05-15

    The objective was to describe the imaging appearances and location of delamination tears of the rotator cuff tendons on non-contrast conventional MR imaging. This study was reviewed and approved by our Institutional Review Board. The reports of 548 consecutive MR examinations of the shoulder were reviewed, looking for mention or description of delamination tears of the rotator cuff. The images of the identified cases were then reviewed by two radiologists to confirm the findings. Correlation with surgical and arthroscopic information was then performed. Delamination tears were defined as horizontal retraction of either the bursal or articular surface of the tendon, manifest as thickening of the torn retracted edge, and/or interstitial splitting of the tendon, manifest as fluid-like high signal intensity on fat-suppressed T2-weighted oblique coronal images. Fourteen cases of delamination tears were identified in 13 patients. Ten of the cases involved the supraspinatus tendon, all with articular surface involvement. Nine of these supraspinatus cases were isolated tears and one occurred as part of a full thickness tear. All 10 of these supraspinatus cases showed medial retraction of the articular surface of the tendon, with thickening of the retracted edge, and 5 of the 10 had a demonstrable horizontal cleft in the interstitium. Four cases involved the subscapularis tendon, with articular surface disruption in three and pure interstitial delamination in one. Medial subluxation of the tendon of the long head of the biceps was present in all four cases. No delamination tears occurred on the bursal surface. Only three of the 14 shoulders underwent surgical repair with one confirmation of supraspinatus delamination, one confirmation of a subscapularis tear that had become a full thickness tear 10 months after initial imaging and another interstitial subscapularis delamination that was not identified arthroscopically. Delamination tears occur most often in the

  5. bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R.; Hui, H. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Bradford, K. J.; Buder, I. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [Université Grenoble Alpes, CEA INAC-SBT, F-38000 Grenoble (France); Fliescher, S. [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Hilton, G. C., E-mail: avieregg@kicp.uchicago.edu [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Collaboration: bicep2 and Keck Array Collaborations; and others

    2015-06-20

    bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

  6. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    Directory of Open Access Journals (Sweden)

    Tanujan Thangarajah

    Full Text Available Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds.In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5, or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5 were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery.Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047, 9 (P = 0.028, and 12 weeks (P = 0.009. In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015, and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039. No failures of tendon-bone healing were noted in either group.Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  7. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    Science.gov (United States)

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  8. The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

    Science.gov (United States)

    Sinicropi, Stefano M; Su, Brian W; Raia, Frank J; Parisien, May; Strauch, Robert J; Rosenwasser, Melvin P

    2005-03-01

    Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model. An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration. Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-A16-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group. Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants.

  9. The prevalence and clinical significance of sonographic tendon abnormalities in asymptomatic ballet dancers: a 24-month longitudinal study.

    Science.gov (United States)

    Comin, Jules; Cook, Jill L; Malliaras, Peter; McCormack, Moira; Calleja, Michelle; Clarke, Andrew; Connell, David

    2013-01-01

    Sonographic abnormalities of the achilles and patellar tendons are common findings in athletes, and tendinopathy is a common cause of pain and disability in athletes. However, it is unclear whether the sonographic changes are pathological or adaptive, or if they predict future injury. We undertook a cohort study to determine what sonographic features of the achilles and patellar tendons are consistent with changes as a result of ballet training, and which may be predictive of future development of disabling tendon symptoms. The achilles and patellar tendons of 79 (35 male, 44 female) professional ballet dancers (members of the English Royal Ballet) were examined with ultrasound, measuring proximal and distal tendon diameters and assessing for the presence of hypoechoic change, intratendon defects, calcification and neovascularity. All subjects were followed for 24 months for the development of patellar tendon or achilles-related pain or injury severe enough to require time off from dancing. Sonographic abnormalities were common among dancers, both male and female, and in both achilles and patellar tendons. Disabling tendon-related symptoms developed in 10 dancers and 14 tendons: 7 achilles (3 right, 4 left) and 7 patellar (2 right, 5 left). The presence of moderate or severe hypoechoic defects was weakly predictive for the development of future disabling tendon symptoms (p=0.0381); there was no correlation between any of the other sonographic abnormalities and the development of symptoms. There was no relationship between achilles or patellar tendons' diameter, either proximal or distal, with an increased likelihood of developing tendon-related disability. The presence of sonographic abnormalities is common in ballet dancers, but only the presence of focal hypoechoic changes predicts the development of future tendon-related disability. This suggests that screening of asymptomatic individuals may be of use in identifying those who are at higher risk of developing

  10. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient

    Directory of Open Access Journals (Sweden)

    James Williams

    2018-06-01

    Full Text Available Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients. Keywords: Acute, Flexor, Tendon, Fracture, Radius, Paediatric

  11. Sonography findings in tears of the extensor pollicis longus tendon and correlation with CT, MRI and surgical findings

    International Nuclear Information System (INIS)

    Ruiz Santiago, Fernando; Garofano Plazas, Pilar; Fernandez, Juan Miguel Tristan

    2008-01-01

    We present our experience in the diagnosis of extensor pollicis longus tendon tears using different imaging methods. In the past 2 years, 12 patients (7 males, 5 females) with extension deficit of distal phalanx of thumb were diagnosed with extensor pollicis longus tendon (EPL) rupture by means of different imaging methods. The ultrasound pattern consisted of a gap between tendon stumps occupied by a continuous (eight cases) or discontinuous (four cases) attenuated hypoechoic string. In nine cases, the tendon ends were identified as a thickened stump-like structure. In the other three cases, tendon stumps were attenuated and mixed with atrophic muscle or wrist subcutaneous fat. All ultrasound findings were confirmed by CT, MR and/or surgical findings

  12. Floating fat in the wrist joint and in the tendon sheaths

    Energy Technology Data Exchange (ETDEWEB)

    Le Corroller, Thomas; Zink, Jean-Vincent; Champsaur, Pierre [Hopital Sainte-Marguerite, Radiology Department, Marseille (France); Parratte, Sebastien; Argenson, Jean-Noel [Hopital Sainte-Marguerite, Orthopaedic Surgery Department, Marseille (France)

    2010-09-15

    A traumatic fat effusion in a tendon sheath is an unreported entity. We report on the clinical and imaging features, including radiography and computed tomography (CT), of a fat-density effusion in the wrist joint and tendon sheaths of the extensor pollicis longus, extensor carpi radialis longus, and extensor carpi radialis brevis in a 28-year-old patient after a roller-skating accident. Radiographs showed a fracture of the distal radius and a wrist joint effusion. Preoperative CT examination exhibited two distinct layers resulting in a fat-fluid level pathognomonic of lipohemarthrosis in the radiocarpal joint. In addition, a fat-density effusion was noted in the sheaths of the second and third compartment extensor tendons. The lipohemarthrosis depicted on imaging classically results from the extrusion of fat from bone marrow into the joint space after an intraarticular fracture. Similarly, a traumatic fat effusion in a tendon sheath presents characteristic imaging features that may help to diagnose a potentially overlooked fracture. (orig.)

  13. Floating fat in the wrist joint and in the tendon sheaths

    International Nuclear Information System (INIS)

    Le Corroller, Thomas; Zink, Jean-Vincent; Champsaur, Pierre; Parratte, Sebastien; Argenson, Jean-Noel

    2010-01-01

    A traumatic fat effusion in a tendon sheath is an unreported entity. We report on the clinical and imaging features, including radiography and computed tomography (CT), of a fat-density effusion in the wrist joint and tendon sheaths of the extensor pollicis longus, extensor carpi radialis longus, and extensor carpi radialis brevis in a 28-year-old patient after a roller-skating accident. Radiographs showed a fracture of the distal radius and a wrist joint effusion. Preoperative CT examination exhibited two distinct layers resulting in a fat-fluid level pathognomonic of lipohemarthrosis in the radiocarpal joint. In addition, a fat-density effusion was noted in the sheaths of the second and third compartment extensor tendons. The lipohemarthrosis depicted on imaging classically results from the extrusion of fat from bone marrow into the joint space after an intraarticular fracture. Similarly, a traumatic fat effusion in a tendon sheath presents characteristic imaging features that may help to diagnose a potentially overlooked fracture. (orig.)

  14. A new surgical technique for traumatic dislocation of posterior tibial tendon with avulsion fracture of medial malleolus.

    Science.gov (United States)

    Jeong, Soon-Taek; Hwang, Sun-Chul; Kim, Dong-Hee; Nam, Dae-Cheol

    2015-01-01

    We introduce a case of traumatic dislocation of the posterior tibial tendon with avulsion fracture of the medial malleolus in a 52-year-old female patient who was treated surgically with periosteal flap and suture anchor fixation. Based in the posteromedial ridge of the distal tibia, a quadrilateral periosteal flap was created and folded over the tendon, followed by fixation on the lateral aspect of the groove by use of multiple suture anchors. Clinical and radiological findings 25 months postoperatively showed well-preserved function of the ankle joint with stable tendon gliding.

  15. Vibration sensitivity of human muscle spindles and Golgi tendon organs.

    Science.gov (United States)

    Fallon, James B; Macefield, Vaughan G

    2007-07-01

    The responses of the various muscle receptors to vibration are more complicated than a naïve categorization into stretch (muscle spindle primary ending), length (muscle spindle secondary endings), and tension (Golgi tendon organs) receptors. To emphasize the similarity of responses to small length changes, we recorded from 58 individual muscle afferents subserving receptors in the ankle or toe dorsiflexors of awake human subjects (32 primary endings, 20 secondary endings, and six Golgi tendon organs). Transverse sinusoidal vibration was applied to the distal tendon of the receptor-bearing muscle, while subjects either remained completely relaxed or maintained a weak isometric contraction of the appropriate muscle. In relaxed muscle, few units responded in a 1:1 manner to vibration, and there was no evidence of a preferred frequency of activation. In active muscle the response profiles of all three receptor types overlapped, with no significant difference in threshold between receptor types. These results emphasize that when intramuscular tension increases during a voluntary contraction, Golgi tendon organs and muscle spindle secondary endings, not just muscle spindle primary endings, can effectively encode small imposed length changes.

  16. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    International Nuclear Information System (INIS)

    Belentani, Clarissa; Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald; Haghighi, Parviz

    2009-01-01

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  17. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Belentani, Clarissa [University of California, Department of Radiology, San Diego, CA (United States); Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald [University of California, Department of Radiology, San Diego, CA (United States); University of California, VA Medical Center, San Diego, CA (United States); Haghighi, Parviz [University of California, VA Medical Center, San Diego, CA (United States); University of California, Department of Histology, San Diego (United States)

    2009-02-15

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  18. Composite inflation confronts BICEP2 and PLANCK

    International Nuclear Information System (INIS)

    Karwan, Khamphee; Channuie, Phongpichit

    2014-01-01

    We examine observational constraints on single-field inflation in which the inflaton is a composite field stemming from a four-dimensional strongly interacting field theory. We confront the predictions with the Planck and very recent BICEP2 data. In the large non-minimal coupling regions, we discover for the minimal composite inflationary model that the predictions lie well inside the joint 68% CL for the Planck data, but is in tension with the recent BICEP2 observations. In the case of the glueball inflationary model, the predictions satisfy the Planck results. However, this model can produce a large tensor-to-scalar ratio consistent with the recent BICEP2 observations if the number of e-foldings is slightly smaller than the range commonly used. For a super Yang-Mills paradigm, we discover that the predictions satisfy the Planck data, and surprisingly a large tensor-to-scalar ratio consistent with the BICEP2 results can also be produced for an acceptable range of the number of e-foldings and of the confining scale. In the small non-minimal coupling regions, all of the models can satisfy the BICEP2 results. However, the predictions of the glueball and superglueball inflationary models cannot satisfy the observational bound on the amplitude of the curvature perturbation launched by Planck, and the techni-inflaton self-coupling in the minimal composite inflationary model is constrained to be extremely small

  19. Proximal Biceps Tendonitis

    Science.gov (United States)

    ... you to have an X-ray , ultrasound, or magnetic resonance imaging (MRI) scan . How Can I Prevent ... to avoid using your injured arm for any lifting or reaching. Ice the affected area. Apply ice ...

  20. Diagnosing Snapping Sartorius Tendon Secondary to a Meniscal Cyst Using Dynamic Ultrasound Avoids Incorrect Surgical Procedure

    Directory of Open Access Journals (Sweden)

    Vipin Asopa

    2013-01-01

    Full Text Available We describe a case of painful snapping in the medial aspect of the knee of a 40-year-old man, following a knee hyperflexion injury. Dynamic real-time ultrasonography determined that the snapping was due to the distal tendon of sartorius passing over a medial meniscal cyst. The patient subsequently underwent arthroscopic decompression of the cyst instead of an inappropriate hamstring tendon harvest procedure, with complete resolution of symptoms.

  1. Ulnar-sided pain due to extensor carpi ulnaris tendon subluxation: a case report

    Directory of Open Access Journals (Sweden)

    Cift Hakan

    2012-11-01

    Full Text Available Abstract Introduction We present the case of a patient with extensor carpi ulnaris tendon subluxation who was first treated for distal radioulnar joint sprain. Case presentation A 25-year-old Caucasian man was seen at our policlinic one month after he had fallen on his outstretched hand. A diagnosis of extensor carpi ulnaris subluxation was made clinically but we also had the magnetic resonance imaging scan of the patient’s wrist which displayed an increased signal on T2-weighted images consistent with inflammation around the extensor carpi ulnaris tendon. The extensor carpi ulnaris tendon was found to be dislocating during supination and relocating during pronation. The sheath was reconstructed using extensor retinaculum due to attenuation of subsheath. Conclusion There was no recurrent dislocation of the extensor carpi ulnaris tendon of the patient at his last follow up 12 months after the operation.

  2. Isolated Tuberculous Tenosynovitis of the Anterior Tibial and Extensor Digitorum Longus Tendons

    Directory of Open Access Journals (Sweden)

    Berhan Genç

    2013-01-01

    Full Text Available Musculoskeletal system is involved in 1-5% of extrapulmonary cases of tuberculosis. Tuberculous tenosynovitis is a rare form of musculoskeletal tuberculosis. Tuberculosis of the tendon sheath in the hand has been seen in a few cases. Involvement of the tendons of the leg is less common. Diagnosis is not easy as there are no specific clinical symptoms or signs. A 33-year-old male presented with painful swelling in the distal right lower limb that caused restriction of movement. Imaging studies showed inflammation and infection of the extensor digitorium longus and tibialis anterior tendons. Histopathological studies showed a necrotizing granulomatous inflammation in the synovial tissue. A diagnosis of tuberculosis was made and medical treatment was initiated that proved successful. Patient remained infection-free at 26-month follow-up examination.

  3. bicep2/ KECK ARRAY . IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P.A.R.; Aikin, R.W.; Barkats, D.; Benton, S.J.; Bischoff, C.A.; Bock, J.J.; Bradford, K.J.; Brevik, J.A.; Buder, I.; Bullock, E.; Dowell, C.D.; Duband, L.; Filippini, J.P.; Fliescher, S.; Golwala, S.R.; Halpern, M.; Hasselfield, M.; Hildebrandt, S.R.; Hilton, G.C.; Hui, H.; Irwin, K.D.

    2015-06-18

    bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS P. A. R. Ade1, R. W. Aikin2, D. Barkats3, S. J. Benton4, C. A. Bischoff5, J. J. Bock2,6, K. J. Bradford5, J. A. Brevik2, I. Buder5, E. Bullock7Show full author list Published 2015 June 18 • © 2015. The American Astronomical Society. All rights reserved. The Astrophysical Journal, Volume 806, Number 2 Article PDF Figures Tables References Citations 273 Total downloads Cited by 6 articles Turn on MathJax Share this article Get permission to re-use this article Article information Abstract bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

  4. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    OpenAIRE

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen ca...

  5. Tendon surveillance requirements - average tendon force

    International Nuclear Information System (INIS)

    Fulton, J.F.

    1982-01-01

    Proposed Rev. 3 to USNRC Reg. Guide 1.35 discusses the need for comparing, for individual tendons, the measured and predicted lift-off forces. Such a comparison is intended to detect any abnormal tendon force loss which might occur. Recognizing that there are uncertainties in the prediction of tendon losses, proposed Guide 1.35.1 has allowed specific tolerances on the fundamental losses. Thus, the lift-off force acceptance criteria for individual tendons appearing in Reg. Guide 1.35, Proposed Rev. 3, is stated relative to a lower bound predicted tendon force, which is obtained using the 'plus' tolerances on the fundamental losses. There is an additional acceptance criterion for the lift-off forces which is not specifically addressed in these two Reg. Guides; however, it is included in a proposed Subsection IWX to ASME Code Section XI. This criterion is based on the overriding requirement that the magnitude of prestress in the containment structure be sufficeint to meet the minimum prestress design requirements. This design requirement can be expressed as an average tendon force for each group of vertical hoop, or dome tendons. For the purpose of comparing the actual tendon forces with the required average tendon force, the lift-off forces measured for a sample of tendons within each group can be averaged to construct the average force for the entire group. However, the individual lift-off forces must be 'corrected' (normalized) prior to obtaining the sample average. This paper derives the correction factor to be used for this purpose. (orig./RW)

  6. Using of Tendinous Plasty in Treatment of Patients with Flexor Tendons of 2–5 Fingers Injury in “Critical” Zone

    Directory of Open Access Journals (Sweden)

    S.I. Kireev

    2009-06-01

    Full Text Available Injury of both superficial and deep tendons of fingers flexors needs to carry out tendinous plasty with excision of distal part of superficial flexor muscle tendon. Use of length measuring method for tendinous transplant allows us to avoid the flexion contracture in future and appearance of functional insufficiency of flexion during postoperative period and rehabilitation of patient.

  7. Articular Cartilage Increases Transition Zone Regeneration in Bone-tendon Junction Healing

    Science.gov (United States)

    Qin, Ling; Lee, Kwong Man; Leung, Kwok Sui

    2008-01-01

    The fibrocartilage transition zone in the direct bone-tendon junction reduces stress concentration and protects the junction from failure. Unfortunately, bone-tendon junctions often heal without fibrocartilage transition zone regeneration. We hypothesized articular cartilage grafts could increase fibrocartilage transition zone regeneration. Using a goat partial patellectomy repair model, autologous articular cartilage was harvested from the excised distal third patella and interposed between the residual proximal two-thirds bone fragment and tendon during repair in 36 knees. We evaluated fibrocartilage transition zone regeneration, bone formation, and mechanical strength after repair at 6, 12, and 24 weeks and compared them with direct repair. Autologous articular cartilage interposition resulted in more fibrocartilage transition zone regeneration (69.10% ± 14.11% [mean ± standard deviation] versus 8.67% ± 7.01% at 24 weeks) than direct repair at all times. There was no difference in the amount of bone formation and mechanical strength achieved. Autologous articular cartilage interposition increases fibrocartilage transition zone regeneration in bone-tendon junction healing, but additional research is required to ascertain the mechanism of stimulation and to establish the clinical applicability. PMID:18987921

  8. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  9. BICEP2. II. Experiment and three-year data set

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Amiri, M.; Davis, G.; Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Buder, I. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Day, P. K.; Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [Université Grenoble Alpes, CEA INAC-SBT, F-38000 Grenoble (France); Fliescher, S., E-mail: ogburn@stanford.edu [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Collaboration: Bicep2 Collaboration; and others

    2014-09-01

    We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

  10. Iliopsoas Tendon Reformation after Psoas Tendon Release

    Directory of Open Access Journals (Sweden)

    K. Garala

    2013-01-01

    Full Text Available Internal snapping hip syndrome, or psoas tendonitis, is a recognised cause of nonarthritic hip pain. The majority of patients are treated conservatively; however, occasionally patients require surgical intervention. The two surgical options for iliopsoas tendinopathy are step lengthening of the iliopsoas tendon or releasing the tendon at the lesser trochanter. Although unusual, refractory snapping usually occurs soon after tenotomy. We report a case of a 47-year-old active female with internal snapping and pain following an open psoas tenotomy. Postoperatively she was symptom free for 13 years. An MRI arthrogram revealed reformation of a pseudo iliopsoas tendon reinserting into the lesser trochanter. The pain and snapping resolved after repeat iliopsoas tendon release. Reformation of tendons is an uncommon sequela of tenotomies. However the lack of long-term studies makes it difficult to calculate prevalence rates. Tendon reformation should be included in the differential diagnosis of failed tenotomy procedures after a period of symptom relief.

  11. Effects of aging and resistance training in rat tendon remodeling.

    Science.gov (United States)

    Marqueti, Rita C; Durigan, João L Q; Oliveira, Anderson José S; Mekaro, Marcelo Shinyu; Guzzoni, Vinicius; Aro, Andrea A; Pimentel, Edson Rosa; Selistre-de-Araujo, Heloisa S

    2018-01-01

    In elderly persons, weak tendons contribute to functional limitations, injuries, and disability, but resistance training can attenuate this age-related decline. We evaluated the effects of resistance training on the extracellular matrix (ECM) of the calcaneal tendon (CT) in young and old rats and its effect on tendon remodeling. Wistar rats aged 3 mo (young, n = 30) and 20 mo (old, n = 30) were divided into 4 groups: young sedentary, young trained, old sedentary (OS), and old trained (OT). The training sessions were conducted over a 12-wk period. Aging in sedentary rats showed down-regulation in key genes that regulated ECM remodeling. Moreover, the OS group showed a calcification focus in the distal region of the CT, with reduced blood vessel volume density. In contrast, resistance training was effective in up-regulating connective tissue growth factor, VEGF, and decorin gene expression in old rats. Resistance training also increased proteoglycan content in young and old rats in special small leucine-rich proteoglycans and blood vessels and prevented calcification in OT rats. These findings confirm that resistance training is a potential mechanism in the prevention of aging-related loss in ECM and that it attenuates the detrimental effects of aging in tendons, such as ruptures and tendinopathies.-Marqueti, R. C., Durigan, J. L. Q., Oliveira, A. J. S., Mekaro, M. S., Guzzoni, V., Aro, A. A., Pimentel, E. R., Selistre-de-Araujo, H. S. Effects of aging and resistance training in rat tendon remodeling. © FASEB.

  12. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.

    Science.gov (United States)

    Wurtzel, Caroline N Wolfe; Burns, Geoffrey T; Zhu, Andy F; Ozer, Kagan

    2017-12-01

    Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Efficacy of labral repair, biceps tenodesis, and diagnostic arthroscopy for SLAP Lesions of the shoulder: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Mowinckel Petter

    2010-10-01

    Full Text Available Abstract Background Surgery for type II SLAP (superior labral anterior posterior lesions of the shoulder is a promising but unproven treatment. The procedures include labral repair or biceps tenodesis. Retrospective cohort studies have suggested that the benefits of tenodesis include pain relief and improved function, and higher patient satisfaction, which was reported in a prospective non-randomised study. There have been no completed randomised controlled trials of surgery for type II SLAP lesions. The aims of this participant and observer blinded randomised placebo-controlled trial are to compare the short-term (6 months and long-term (2 years efficacy of labral repair, biceps tenodesis, and placebo (diagnostic arthroscopy for alleviating pain and improving function for type II SLAP lesions. Methods/Design A double-blind randomised controlled trial are performed using 120 patients, aged 18 to 60 years, with a history for type II SLAP lesions and clinical signs suggesting type II SLAP lesion, which were documented by MR arthrography and arthroscopy. Exclusion criteria include patients who have previously undergone operations for SLAP lesions or recurrent shoulder dislocations, and ruptures of the rotator cuff or biceps tendon. Outcomes will be assessed at baseline, three, six, 12, and 24 months. Primary outcome measures will be the clinical Rowe Score (1988-version and the Western Ontario Instability Index (WOSI at six and 24 months. Secondary outcome measures will include the Shoulder Instability Questionnaire (SIQ, the generic EuroQol (EQ-5 D and EQ-VAS, return to work and previous sports activity, complications, and the number of reoperations. Discussion The results of this trial will be of international importance and the results will be translatable into clinical practice. Trial Registration [ClinicalTrials.gov NCT00586742

  14. Bicep2. III. INSTRUMENTAL SYSTEMATICS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Buder, I.; Karkare, K. S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [SBT, Commissariat à l’Energie Atomique, Grenoble (France); Fliescher, S. [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Hilton, G. C.; Irwin, K. D., E-mail: csheehy@uchicago.edu [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Collaboration: Bicep2 Collaboration; and others

    2015-12-01

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10{sup −3}.

  15. Bicep2. III. INSTRUMENTAL SYSTEMATICS

    International Nuclear Information System (INIS)

    Ade, P. A. R.; Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R.; Barkats, D.; Benton, S. J.; Bischoff, C. A.; Buder, I.; Karkare, K. S.; Bullock, E.; Dowell, C. D.; Duband, L.; Fliescher, S.; Halpern, M.; Hasselfield, M.; Hilton, G. C.; Irwin, K. D.

    2015-01-01

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10 −3

  16. Stiffness analysis of spring mechanism for semi automatic gripper motion of tendon driven remote manipulator

    International Nuclear Information System (INIS)

    Yu, Seung Nam; Lee, Jong Kwang

    2012-01-01

    Remote handling manipulators are widely used for performing hazardous tasks, and it is essential to ensure the reliable performance of such systems. Toward this end, tendon driven mechanisms are adopted in such systems to reduce the weight of the distal parts of the manipulator while maintaining the handling performance. In this study, several approaches for the design of a gripper system for a tendon driven remote handling system are introduced. Basically, this gripper has an underactuated spring mechanism that is combined with a slave manipulator triggered by a master operator. Based on the requirements under the specified tendon driven mechanism, the connecting position of the spring system on the gripper mechanism and kinematic influence coefficient (KIC) analysis are performed. As a result, a suitable combination of components for the proper design of the target system is presented and verified

  17. A Misdiagnosis of Traumatic Hypersupination of the Distal Radioulnar Joint: A Case Report

    Directory of Open Access Journals (Sweden)

    Vipin Asopa

    2013-01-01

    Full Text Available Traumatic hypersupination injury of the distal radioulnar joint is a rare injury, and occurs when sufficient supination force is applied to the joint so as to tear the volar radioulnar ligament, resulting in separation of the triangular fibrocartilage complex, and subluxation of the tendon of extensor carpi ulnaris. This allows the distal ulna to rotate such that the ulnar styloid comes to lie adjacent to the ulna notch of the radius. Treatment of this injury requires manipulation of the joint, under anaesthesia or sedation. We describe a case where posttraumatic radiological investigation of a patient with an anatomical variation of the wrist when in supination resembled a traumatic hypersupination injury of the distal radioulnar joint. A review of the literature has revealed this to be the first reported case of this type.

  18. Toward an understanding of foreground emission in the BICEP2 region

    International Nuclear Information System (INIS)

    Flauger, Raphael; Hill, J. Colin; Spergel, David N.

    2014-01-01

    BICEP2 has reported the detection of a degree-scale B-mode polarization pattern in the Cosmic Microwave Background (CMB) and has interpreted the measurement as evidence for primordial gravitational waves. Motivated by the profound importance of the discovery of gravitational waves from the early Universe, we examine to what extent a combination of Galactic foregrounds and lensed E-modes could be responsible for the signal. We reanalyze the BICEP2 results and show that the 100 ×150 GHz and 150 ×150 GHz data are consistent with a cosmology with r=0.2 and negligible foregrounds, but also with a cosmology with r=0 and a significant dust polarization signal. We give independent estimates of the dust polarization signal in the BICEP2 region using a number of different approaches: (1) data-driven models based on Planck 353 GHz intensity, polarization fractions inferred from the same Planck data used by the BICEP2 team but corrected for CMB and CIB contributions, and polarization angles from starlight polarization data or the Planck sky model; (2) the same set of pre-Planck models used by the BICEP2 team but taking into account the higher polarization fractions observed in the CMB- and CIB-corrected map; (3) a measurement of neutral hydrogen gas column density N HI in the BICEP2 region combined with an extrapolation of a relation between HI column density and dust polarization derived by Planck; and (4) a dust polarization map based on digitized Planck data, which we only use as a final cross-check. While these approaches are consistent with each other, the expected amplitude of the dust polarization power spectrum remains uncertain by about a factor of three. The lower end of the prediction leaves room for a primordial contribution, but at the higher end the dust in combination with the standard CMB lensing signal could account for the BICEP2 observations, without requiring the existence of primordial gravitational waves. By measuring the cross-correlations between the

  19. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog.

    Science.gov (United States)

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures.

  20. Tendons in the plantar aspect of the foot: MR imaging and anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Rodrigo [University of California San Diego, Radiology, San Diego, CA (United States); Fleury Medical Center, Radiology, Sao Paulo, SP (Brazil); Aguiar, Rodrigo; Trudell, Debra; Resnick, Donald [University of California San Diego, Radiology, San Diego, CA (United States)

    2007-02-15

    The purpose of this anatomic imaging study was to illustrate the normal complex anatomy of tendons of the plantar aspect of the ankle and foot using magnetic resonance (MR) imaging with anatomic correlation in cadavers. Seven fresh cadaveric feet (obtained and used according to institutional guidelines, with informed consent from relatives of the deceased) were studied with intermediate-weighted fast-spin-echo MR imaging. For anatomic analysis, cadaveric specimens were sectioned in 3-mm-thick slices in the coronal and axial planes that approximated the sections acquired at MR imaging. The entire courses of the tendons into the plantar aspect of the foot were analyzed. The tibialis posterior tendon has a complex distal insertion. The insertions in the navicular, second, and third cuneiforms bones were identify in all cases using axial and coronal planes. A tendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons was identified in five of our specimens (71%). The coronal plane provided the best evaluation. The peroneus longus tendon changes its direction at three points then obliquely crosses the sole and inserts in the base of the first metatarsal bone and the plantar aspect of the first cuneiform. MR imaging provides detailed information about the anatomy of tendons in the plantar aspect of the ankle and foot. It allows analysis of their insertions and the intertendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons. (orig.)

  1. [Distal soft-tissue procedure in hallux valgus deformity].

    Science.gov (United States)

    Arbab, D; Wingenfeld, C; Frank, D; Bouillon, B; König, D P

    2016-04-01

    Distal, lateral soft tissue release to restore mediolateral balance of the first metatarsophalangeal (MTP) joint in hallux valgus deformity. Incision of the adductor hallucis tendon from the fibular sesamoid, the lateral capsule, the lateral collateral ligament, and the lateral metatarsosesamoid ligament. Hallux valgus deformities or recurrent hallux valgus deformities with an incongruent MTP joint. General medical contraindications to surgical interventions. Painful stiffness of the MTP joint, osteonecrosis, congruent joint. Relative contraindications: connective tissue diseases (Marfan syndrome, Ehler-Danlos syndrome). Longitudinal, dorsal incision in the first intermetatarsal web space between the first and second MTP joint. Blunt dissection and identification of the adductor hallucis tendon. Release of the adductor tendon from the fibular sesamoid. Incision of the lateral capsule, the lateral collateral ligament, and the lateral metatarsosesamoid ligament. Postoperative management depends on bony correction. In joint-preserving procedures, dressing for 3 weeks in corrected position. Subsequently hallux valgus orthosis at night and a toe spreader for a further 3 months. Passive mobilization of the first MTP joint. Postoperative weight-bearing according to the osteotomy. A total of 31 patients with isolated hallux valgus deformity underwent surgery with a Chevron and Akin osteotomy and a distal medial and lateral soft tissue balancing. The mean preoperative intermetatarsal (IMA) angle was 12.3° (range 11-15°); the hallux valgus (HV) angle was 28.2° (25-36°). The mean follow-up was 16.4 months (range 12-22 months). The mean postoperative IMA correction ranged between 2 and 7° (mean 5.2°); the mean HV correction was 15.5° (range 9-21°). In all, 29 patients (93%) were satisfied or very satisfied with the postoperative outcome, while 2 patients (7%) were not satisfied due to one delayed wound healing and one recurrent hallux valgus deformity. There were no

  2. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  3. Treatment of acute achilles tendon rupture with the panda rope bridge technique.

    Science.gov (United States)

    Yin, Liangjun; Wu, Yahong; Ren, Changsong; Wang, Yizhong; Fu, Ting; Cheng, Xiangjun; Li, Ruidong; Nie, Mao; Mu, Yuan

    2018-03-01

    Although nonsurgical methods and many surgical techniques have been developed for repairing a ruptured Achilles tendon, there is no consensus on its best treatment. In this article, a novel minimally invasive technique called the Panda Rope Bridge Technique (PRBT) is described. Patient with acute Achilles tendon rupture was operated on in the prone position. The PRBT begin with making the proximal bridge anchor (Krackow sutures in the myotendinous junction), the distal bridge anchor (two suture anchors in the calcaneus bone) and the ropes (threads of the suture anchors) stretched between the anchor sites. Then a small incision was made to debride and reattach the stumps of ruptured tendon. After the surgery, no cast or splint fixation was applied. All patients performed enhanced recovery after surgery (ERAS), which included immediate ankle mobilisation from day 1, full weight-bearing walking from day 5 to 7, and gradually take part in athletic exercises from 8 weeks postoperatively. PBRT was performed in 11patients with acute Achilles tendon rupture between June 2012 and June 2015. No wound infection, fistula, skin necrosis, sural nerve damage, deep venous thrombosis or tendon re-rupture was found. One year after the surgery, all patients reported 100 AOFAS ankle-hindfoot score points and the mean ATRS was 96.6. The PRBT is a simple, effective and minimally invasive technique, with no need for immobilisation of the ankle, making possible immediate and aggressive postoperative rehabilitation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.

    Science.gov (United States)

    Huh, Jeannie; Easley, Mark E; Nunley, James A

    2016-06-01

    An Achilles sleeve avulsion occurs when the tendon ruptures distally from its calcaneal insertion as a continuous "sleeve." This relatively rare injury pattern may not be appreciated until the time of surgery and can be challenging to treat because, unlike a midsubstance rupture, insufficient tendon remains on the calcaneus to allow for end-to-end repair, and unlike a tuberosity avulsion fracture, any bony element avulsed with the tendon is inadequate for internal fixation. This study aimed to highlight the characteristics of Achilles sleeve avulsions and present the outcomes of operative repair using suture anchor fixation. A retrospective analysis was conducted on 11 consecutive Achilles tendon sleeve avulsions (10 males, 1 female; mean age 44 years) that underwent operative repair between 2008 and 2014. Patient demographics, injury presentation, and operative details were reviewed. Postoperative outcomes were collected at a mean follow-up of 38.4 (range, 12-83.5) months, including the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score, visual analog scale (VAS) for pain, plantarflexion strength, patient satisfaction, and complications. Eight patients (72.7%) had preexisting symptoms of insertional Achilles disease. Ten of 11 (90.9%) injuries were sustained during recreational athletic activity. An Achilles sleeve avulsion was recognized preoperatively in 7 of 11 (64%) cases, where lateral ankle radiographs demonstrated a small radiodensity several centimeters proximal to the calcaneal insertion. Intraoperatively, 90.9% of sleeve avulsions had a concomitant Haglund deformity and macroscopic evidence of insertional tendinopathy. All patients healed after suture anchor repair. The average AOFAS score was 92.8 and VAS score was 0.9. Ten patients (90.9%) were completely satisfied. One complication occurred, consisting of delayed wound healing. Achilles tendon sleeve avulsions predominantly occurred in middle-aged men with preexisting insertional

  5. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  6. Ultrasonographic evaluation of the canine shoulder.

    Science.gov (United States)

    Long, C D; Nyland, T G

    1999-01-01

    The aim of this study was to determine the normal ultrasonographic anatomy of the canine shoulder. Fourteen shoulders from 7 clinically normal mid-sized dogs were radiographed and imaged using high frequency ultrasound. Each shoulder was isolated postmortem, and the ultrasonographic and gross anatomy was studied during dissection. The ultrasonographic appearance of the shoulder specimens was similar to that found in the live dogs. Twenty-four shoulders isolated postmortem from 12 variably sized dogs were also used to characterize the normal ultrasound anatomy over a range of sizes. Important anatomic structures that could be consistently evaluated were the biceps tendon and bursa, the bicipital groove surface, the supraspinatous tendon, the infraspinatous tendon, the teres minor tendon, and the caudal aspect of the humeral head. Results of ultrasonographic examination of 4 dogs with shoulder lameness are described to illustrate some applications of canine shoulder ultrasonography in the evaluation of the canine shoulder. In these dogs, ultrasound was a valuable tool to evaluate effusion and synovial proliferation within the bicipital bursa, supraspinatous and biceps tendinitis, biceps tendon strain, and dystrophic calcification.

  7. An unusual metastasis of lung adenocarcinoma: Biceps brachii muscle

    Directory of Open Access Journals (Sweden)

    Muzaffer Sariaydin

    2016-01-01

    Full Text Available Skeletal muscle metastasis of nonsmall cell lung carcinoma (NSCLC is a rare occurrence, and the most effective treatment modality is currently unknown. In this case presentation, we report a patient with NSCLC who underwent palliative radiotherapy for biceps muscle metastasis of NSLCS. Our case was a 49-year-old woman who had lung adenocarcinoma with biceps muscle metastasis. She had been followed up for 2 years due to Stage IV lung adenocarcinoma from whom a biopsy was taken from a painful mass in right arm that was found to be compatible with metastasis of lung adenocarcinoma. She had palliative radiotherapy for her painful mass and systemic chemotherapy was planned. After palliative radiotherapy, the pain originating from the metastatic mass in right biceps muscle alleviated. Palliative radiotherapy can be a valuable treatment option for cases with skeletal muscle metastasis.

  8. A radiographic study of the distal interphalangeal joint and navicular bursa of the horse

    International Nuclear Information System (INIS)

    Gibson, K.T.; McIlwraith, C.W.; Park, R.D.

    1990-01-01

    Radiographic contrast studies were used in 50 forelimbs from 13 live horses and 12 fresh adult cadavers to determine the frequency of communication between the navicular bursa and the distal interphalangeal joint. Injections of contrast medium were made into the dorsal aspect of the distal interphalangeal joint of one limb and into the navicular bursa of the other forelimb of each horse. In 25 limbs in which contrast medium was injected into the distal interphalangeal joint, no communication was demonstrated between the joint and the navicular bursa. In 20 of the 25 limbs in which injection was made into the navicular bursa, no communication between joint and bursa was seen. In five horses, contrast medium was visible in both the distal interphalangeal joint and the navicular bursa. However, in four of five horses the communication was clearly iatrogenic. In both limbs of one horse, contrast medium was seen to enter the digital flexor tendon sheath after injection into the navicular bursa.There is probably no naturally occurring communication between the navicular bursa and distal interphalangeal joint in the horse

  9. Distribution of skeletal muscle involvement in autosomal recessive distal muscular dystrophy

    International Nuclear Information System (INIS)

    Mizusawa, Hidehiro; Nakanishi, Takao; Kobayashi, Fumie.

    1987-01-01

    Distribution of skeletal muscle involvement in 5 cases with autosomal recessive distal muscular dystrophy was studied clinically and by computed tomography (CT). Manual muscle test showed muscle involvement with a predilection for flexors in the lower leg and adductors in the thigh. Flexion and extension of the thigh and the lower leg was impaired to similar degree. In progressed cases, neck flexors and trunk muscles were also affected mildly. CT disclosed more clearly the preferential involvement of flexors in the lower leg, and involvement of both hamstrings · adductors group and extensors group of the thigh to similar degree. However, m. popliteus was curiously well preserved. In addition, there was a stage showing high density and hypertrophy of m. sartorius, m. gracilis, m. adductor, m. biceps femoris, m. semimenbranosus, m. semitendinosus or m. rectus femoris, which in thought to be compensatory hypertrophy. M. gluteus minimus in the pelvic girdle and m. dorsi proprii in the trunk were also liable to be affected. The CT findings are regarded as characteristic features noted clearly before muscle weakness and atrophy become apparent clinically. CT is very useful for distinguishing distal muscular dystrophy from rimmed vacuolar distal myopathy in which m. quadriceps femoris and flexors of the lower leg are usually well preserved without compensatory hypertrophy on CT. (author)

  10. Bicipital tendinitis and tenosynovitis in the dog: a study of 15 cases.

    Science.gov (United States)

    Bruce, W J; Burbidge, H M; Bray, J P; Broome, C J

    2000-04-01

    To describe the clinical, radiographic, and sonographic features of 15 dogs with bicipital tendinitis and tenosynovitis, classify them according to cause, and evaluate the long-term efficacy of treatment. Dogs exhibiting forelimb lameness with pain localised to the biceps tendon were included in the study. Sonographic examination of the tendon and tendon sheath, and radiographic examination including positive contrast arthrograms of the shoulder joint were performed, and assessed for features consistent with biceps tendon disease. In some cases, synovial-fluid analysis and surgical investigation were also undertaken. The causes of the conditions were classified as either traumatic, mechanical, neoplastic or inflammatory. Dogs were treated conservatively with rest and anti-inflammatory drugs, or surgically by either transection of the transverse humeral ligament or tenodesis of the biceps tendon. Assessment of the effects of treatment was made by re-examination at six weeks and from information gained by telephone interview with the dog's owner at longer-term follow-up. Bicipital tendinitis and tenosynovitis were common causes of forelimb lameness in active, middle-aged or older, medium to large-breed dogs. The most sensitive physical tests for localising pain to the biceps apparatus were shoulder flexion with the elbow extended, focal digital pressure applied directly to the biceps origin, and the biceps retraction test. Sonographic assessment was found to be more sensitive than shoulder radiography or arthrography for characterising the lesion. Conservative treatment of 11 traumatic cases resulted in good or excellent function at long-term follow-up. One mechanical bicipital tendinitis secondary to mineral deposits within the supraspinatus tendon improved following transection of the transverse humeral ligament and removal of the deposits. One of two cases of inflammatory tendinitis/ tenosynovitis improved following tenodesis. One dog with neoplastic disease did

  11. Toward an Understanding of Foreground Emission in the BICEP2 Region

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    BICEP2 has reported the detection of a degree-scale B-mode polarization pattern in the Cosmic Microwave Background (CMB) and has interpreted the measurement as evidence for primordial gravitational waves. Motivated by the profound importance of the discovery of gravitational waves from the early Universe, I will discuss to what extent a combination of Galactic foregrounds and lensed E-modes could be responsible for the signal. I will present independent estimates of the dust polarization signal in the BICEP2 region using several different approaches. These estimates of the dust polarization signal in the BICEP2 region are consistent with each other, but the expected amplitude of the dust polarization power spectrum is uncertain by about a factor of three. The lower end of the prediction leaves room for a primordial contribution, but at the higher end the dust in combination with the standard CMB lensing signal could account for the BICEP2 observations, without requiring the existence of primordial gravitatio...

  12. Extensor and flexor digit synovial sheath, sac and synovial capsule in the distal part of the limbs in buffalos and camels and its relation of surgical interference

    Directory of Open Access Journals (Sweden)

    S. AL-sadi

    2010-01-01

    Full Text Available Sixty one samples of the distal parts of limbs were obtained from different ages of buffalo and camels of both sex to study the synovial structures to determine the suitable sites for injection of surgical interference. The result showed that extensor digit synovial sheath was extend between middle or distal part of metacarpal (metatarsal to the extensor processes and this formed with synovial capsule dorsal pouches which serve in surgical interference. The flexor digit synovial sheath extended to palmar (planter between distal extremity of metacarpal (metatarsal to the middle of second phalanx in buffalo while in camel it extended to the proximal extremity of second phalanx, that sheath was formed with suspensory ligament and sessamoid bone palmar or planter pouches which were serve the surgical interference. Fourth synovial bursa observed situated dorsally between the extensor digit laterals tendon and capsule of fetlock joint, forms site of injection during surgical interference, while the other two synovial bursa were located to palmer (planter between deep flexor tendon and distal sessamoid bone in buffalo while in camel these bursa were located between deep flexor tendon and cartilage of the second phalanx, these bursa were served for surgical interference. The synovial capsule which serve the surgical interference through digit cushion these were shown extended from the claw capsule. The result show that surgical interference was form six pouches in buffalo and eight pouches in camel, which formed by synovial structures and the tissue associated with them.

  13. Faraday scaling and the Bicep2 observations

    CERN Document Server

    Giovannini, Massimo

    2014-01-01

    As repeatedly speculated in the past, the linear polarization of the Cosmic Microwave Background can be rotated via the Faraday effect. An economic explanation of the recent Bicep2 observations, not relying on long-wavelength tensor modes of the geometry, would stipulate that the detected B mode comes exclusively from a Faraday rotated E mode polarization. We show hereunder that this interpretation is ruled out by the existing upper limits on the B mode polarization obtained by independent experiments at observational frequencies much lower than the operating frequency of the Bicep2 experiment. We then derive the fraction of the observed B mode polarization ascribable to the Faraday effect and suggest a dedicated experimental strategy for its detection.

  14. A histologic analysis of the effects of stainless steel and titanium implants adjacent to tendons: an experimental rabbit study.

    Science.gov (United States)

    Nazzal, Adam; Lozano-Calderón, Santiago; Jupiter, Jesse B; Rosenzweig, Jaime S; Randolph, Mark A; Lee, Sang Gil P

    2006-09-01

    The current trend is to treat distal radius fractures with open reduction and internal fixation with either titanium or stainless steel plates. Both provide stable fixation; however, there is minimal evidence concerning the soft-tissue response to these materials. Our objective was to evaluate the response of adjacent extensor tendons to titanium and stainless steel in a rabbit in vivo model and to evaluate the influence of time. Forty rabbits were divided into 5 groups of 8 rabbits each. Groups I and II had unilateral osteotomy of the distal radius followed by dorsal fixation with titanium and stainless steel plates, respectively. Groups III and IV had fixation with titanium and stainless steel, respectively, but without osteotomy. Group V had surgical dissection without osteotomy or plates. Two animals per group were killed at 1, 4, 12, and 24 weeks. The specimens (distal radius, plate, overlying soft tissue, and extensor tendon) were harvested en bloc for histologic analysis. For interface preservation between implant and tissues the specimens were embedded in methylmethacrylate, sectioned, and stained with hematoxylin-eosin. Histologic analysis showed a fibrous tissue layer formed over both implants between the plate and the overlying extensor tendons in the groups treated with plating independently of the material and the presence or absence of osteotomy. This fibrous layer contained the majority of debris. Metallic particles were not observed in the tendon or muscle substance of any animals; however, they were visualized in the tenosynovium. Hematoxylin-eosin-stained sections of groups I through IV showed proliferative fibroblasts and metallic particles; however, this layer was not observed in group V. Statistical analysis did not show differences between the groups regarding the number of cells or metallic particles. Our results indicate that both implants generated adjacent reactive inflammatory tissue and particulate debris. There was no difference in cell

  15. Voluntary activation of biceps-to-triceps and deltoid-to-triceps transfers in quadriplegia.

    Science.gov (United States)

    Peterson, Carrie L; Bednar, Michael S; Bryden, Anne M; Keith, Michael W; Perreault, Eric J; Murray, Wendy M

    2017-01-01

    The biceps or the posterior deltoid can be transferred to improve elbow extension function for many individuals with C5 or C6 quadriplegia. Maximum strength after elbow reconstruction is variable; the patient's ability to voluntarily activate the transferred muscle to extend the elbow may contribute to the variability. We compared voluntary activation during maximum isometric elbow extension following biceps transfer (n = 5) and deltoid transfer (n = 6) in three functional postures. Voluntary activation was computed as the elbow extension moment generated during maximum voluntary effort divided by the moment generated with full activation, which was estimated via electrical stimulation. Voluntary activation was on average 96% after biceps transfer and not affected by posture. Individuals with deltoid transfer demonstrated deficits in voluntary activation, which differed by posture (80% in horizontal plane, 69% in overhead reach, and 70% in weight-relief), suggesting inadequate motor re-education after deltoid transfer. Overall, individuals with a biceps transfer better activated their transferred muscle than those with a deltoid transfer. This difference in neural control augmented the greater force-generating capacity of the biceps leading to increased elbow extension strength after biceps transfer (average 9.37 N-m across postures) relative to deltoid transfer (average 2.76 N-m across postures) in our study cohort.

  16. Isocurvature perturbations and tensor mode in light of Planck and BICEP2

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, Masahiro; Yokoyama, Shuichiro [Institute for Cosmic Ray Research, University of Tokyo, Kashiwa 277-8582 (Japan); Sekiguchi, Toyokazu [Helsinki Institute of Physics, University of Helsinki, PO Box 64, FIN-00014 (Finland); Takahashi, Tomo, E-mail: kawasaki@icrr.u-tokyo.ac.jp, E-mail: toyokazu.sekiguchi@helsinki.fi, E-mail: tomot@cc.saga-u.ac.jp, E-mail: shu@icrr.u-tokyo.ac.jp [Department of Physics, Saga University, Saga 840-8502 (Japan)

    2014-08-01

    We investigate the degeneracy of the isocurvature perturbations and the primordial gravitational waves, by using recent observations of the cosmic microwave background (CMB) reported by Planck and BICEP2 collaborations. We show that the tension in the bound on the tensor-to-scalar ratio r between Planck and BICEP2 can be resolved by introducing the anti-correlated isocurvature perturbations. Quantitatively, we find that with the anti-correlated isocurvature perturbations the constraints on r from Planck alone and BICEP2 results can be consistent at 68 % C.L.

  17. FIBRILLINS IN TENDON

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    2016-10-01

    Full Text Available Tendons among connective tissue, mainly collagen, contain also elastic fibres made of fibrillin 1, fibrillin 2 and elastin that are broadly distributed in tendons and represent 1-2% of the dried mass of the tendon. Only in the last years, studies on structure and function of elastic fibres in tendons have been performed. Aim of this review is to revise data on the organization of elastic fibres in tendons, in particular fibrillin structure and function, and on the clinical manifestations associated to alterations of elastic fibres in tendons. Indeed, microfibrils may contribute to tendon mechanics; therefore, their alterations may cause joint hypermobility and contractures which have been found to be clinical features in patients with Marfan syndrome and Beals syndrome. The two diseases are caused by mutations in genes FBN1 and FBN2 encoding fibrillin 1 and fibrillin 2, respectively.

  18. Orthotopic Transplantation of Achilles Tendon Allograft in Rats

    Science.gov (United States)

    Aynardi, Michael; Zahoor, Talal; Mitchell, Reed; Loube, Jeffrey; Feltham, Tyler; Manandhar, Lumanti; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-01-01

    The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at −80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully

  19. Location of Rotator Cuff Tear Initiation: A Magnetic Resonance Imaging Study of 191 Shoulders.

    Science.gov (United States)

    Jeong, Jeung Yeol; Min, Seul Ki; Park, Keun Min; Park, Yong Bok; Han, Kwang Joon; Yoo, Jae Chul

    2018-03-01

    Degenerative rotator cuff tears (RCTs) are generally thought to originate at the anterior margin of the supraspinatus tendon. However, a recent ultrasonography study suggested that they might originate more posteriorly than originally thought, perhaps even from the isolated infraspinatus (ISP) tendon, and propagate toward the anterior supraspinatus. Hypothesis/Purpose: It was hypothesized that this finding could be reproduced with magnetic resonance imaging (MRI). The purpose was to determine the most common location of degenerative RCTs by using 3-dimensional multiplanar MRI reconstruction. It was assumed that the location of the partial-thickness tears would identify the area of the initiation of full-thickness tears. Cross-sectional study; Level of evidence, 3. A retrospective analysis was conducted including 245 patients who had RCTs (nearly full- or partial-thickness tears) at the outpatient department between January 2011 and December 2013. RCTs were measured on 3-dimensional multiplanar reconstruction MRI with OsiriX software. The width and distance from the biceps tendon to the anterior margin of the tear were measured on T2-weighted sagittal images. In a spreadsheet, columns of consecutive numbers represented the size of each tear (anteroposterior width) and their locations with respect to the biceps brachii tendon. Data were pooled to graphically represent the width and location of all tears. Frequency histograms of the columns were made to visualize the distribution of tears. The tears were divided into 2 groups based on width (group A, location related to size. The mean width of all RCTs was 11.9 ± 4.1 mm, and the mean length was 11.1 ± 5.0 mm. Histograms showed the most common location of origin to be 9 to 10 mm posterior to the biceps tendon. The histograms of groups A and B showed similar tear location distributions, indicating that the region approximately 10 mm posterior to the biceps tendon is the most common site of tear initiation. These

  20. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration.

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-12-15

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7-21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy.

  1. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration☆

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-01-01

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7–21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy. PMID:25317130

  2. Pectoralis Major Tear with Retracted Tendon: How to Fill the Gap? Reconstruction with Hamstring Autograft and Fixation with an Interference Screw

    Directory of Open Access Journals (Sweden)

    L. Baverel

    2017-01-01

    Full Text Available Rupture of the pectoralis major tendon is considered an uncommon injury and a significant number of ruptures are missed or diagnosed late, leading to a chronic tear. We report an open reconstruction technique and its outcomes in a case of chronic and retracted PM tear. At the last follow-up (12 months, the patient was pain-free, with a visual analogic scale at 0 all the time. He was very satisfied concerning the cosmetic and clinical results. The constant score was 93%, the SST value 95%, and the Quick DASH score 4.5. MRI performed one year postoperatively confirmed the continuity between PM tendon and graft, even if the aspect of the distal tendon seemed to be thinner than normal PM tendon. The excellent clinical outcomes at one-year follow-up suggest that PM tear with major tendon retraction can be reliably reconstructed with hamstring autograft, using a bioabsorbable screw to optimize the fixation device. This technique has proven its simplicity and efficiency to fill the gap.

  3. Results of treatment of the calcific tendinitis of the shoulder supraspinatus muscle tendon

    Directory of Open Access Journals (Sweden)

    S. S. Strafun

    2017-12-01

    Full Text Available The aim of the study was to identify and compare the results of conservative and surgical treatment of the calcific tendinitis of the shoulder supraspinatus muscle tendon. Materials and methods. The clinical group consisted of 120 patients with calcific tendinitis of supraspinatus tendon. All patients were divided into two groups, according to the operative or conservative treatment, each of these groups have been subdivided into two (with calcific deposits less or more than 1.5 cm in length according to Bosworth radiological classification. Conservative treatment ("needling" included: evacuation of calcific deposits with saline under ultrasound control with subsequent injection of prolonged corticosteroid into the subacromial space, use of nonsteroid anti-inflammatory drugs, physiotherapy. Surgical treatment included: evacuation of calcium deposits from the tendon followed by rotator cuff repair and biceps tendon tenodesis at the proximal third of the intertubercular groove. Results. In the majority of patients, after the "needling" of little - 1.5 cm calcific deposits (55 patients - 45.8% clinical and radiographic healing occurred in 2 weeks after procedure. The level of pain in average was 2,39 ± 0,39 points according to VAS scale and function of the shoulder joint has increased in average to 40,26 ± 4,39 points on Oxford Shoulder Score. In 3 months after treatment begining, the best average results were obtained in patients with calcific deposits less than 1.5 cm - 43 ± 3,8 points on Oxford Shoulder Score, the worst 26 ± 4,8 points - in patients with calcific deposits bigger than 1.5 cm who underwent conservative treatment (р≤0,05. Conclusions. In group of patients after surgical treatment, size of calcific deposits did not significantly affect the treatment result (р≤0,01. Slightly better results were obtained in patients with calcific deposits size less than1.5 cm - 39 ± 3,8 points on Oxford Shoulder Score.

  4. BICEP2, Planck, spinorial space-time, pre-Big Bang.

    Directory of Open Access Journals (Sweden)

    Gonzalez-Mestres Luis

    2015-01-01

    Full Text Available The field of Cosmology is currently undergoing a positive and constructive crisis. Controversies concerning inflation are not really new. But after the 2013-2014 Planck and BICEP2 announcements, and the more recent joint analysis by Planck, BICEP2 and the Keck Array (PBKA, the basic issues can involve more direct links between the Mathematical Physics aspects of cosmological patterns and the interpretation of experimental results. Open questions and new ideas on the foundations of Cosmology can emerge, while future experimental and observational programs look very promising. The BICEP2 result reporting an excess of B-mode polarization signal of the cosmic microwave background (CMB radiation was initially presented as a signature of primordial gravitational waves from cosmic inflation. But polarized dust emission can be at the origin of such a signal, and the evidence claimed by BICEP2 is no longer secure after the PBKA analysis. Furthermore, even assuming that significant CMB B-mode polarization has indeed been generated by the early Universe, its theoretical and cosmological interpretation would be far from obvious. Inflationary gravitational waves are not the only possible source of primordial CMB B-modes. Alternative cosmologies such as pre-Big Bang patterns and the spinorial space-time (SST we introduced in 1996-97 can naturally produce this polarization. Furthermore, the SST automatically generates for each comoving observer a local privileged space direction (PSD whose existence may have been confirmed by Planck data. If such a PSD exists, vector perturbations have most likely been strong in the early Universe and may have produced CMB B-modes. Pre-Big Bang cosmologies can also generate gravitational waves in the early Universe without inflation. After briefly describing detectors devoted to the study of the CMB polarization, we discuss the situation emerging from BICEP2 results, Planck results and the PBKA analysis. In particular, we

  5. EFFECT OF THE SHOULDER POSITION ON THE BICEPS BRACHII EMG IN DIFFERENT DUMBBELL CURLS

    Directory of Open Access Journals (Sweden)

    Taian M.M. Vieira

    2009-03-01

    Full Text Available Incline Dumbbell Curl (IDC and Dumbbell Preacher Curl (DPC are two variations of the standard Dumbbell Biceps Curl (DBC, generally applied to optimize biceps brachii contribution for elbow flexion by fixing shoulder at a specific angle. The aim of this study is to identify changes in the neuromuscular activity of biceps brachii long head for IDC, DPC and DBC exercises, by taking into account the changes in load moment arm and muscle length elicited by each dumbbell curl protocol. A single cycle (concentric-eccentric of DBC, IDC and DPC, was applied to 22 subjects using a submaximal load of 40% estimated from an isometric MVC test. The neuromuscular activity of biceps brachii long head was compared by further partitioning each contraction into three phases, according to individual elbow joint range of motion. Although all protocols elicited a considerable level of activation of the biceps brachii muscle (at least 50% of maximum RMS, the contribution of this muscle for elbow flexion/extension varied among exercises. The submaximal elbow flexion (concentric elicited neuro muscular activity up to 95% of the maximum RMS value during the final phase of IDC and DBC and 80% for DPC at the beginning of the movement. All exercises showed significant less muscle activity for the elbow extension (eccentric. The Incline Dumbbell Curl and the classical Dumbbell Biceps Curl resulted in similar patterns of biceps brachii activation for the whole range of motion, whereas Dumbbell Preacher Curl elicited high muscle activation only for a short range of elbow joint angle

  6. Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft.

    Science.gov (United States)

    Rhee, Sung Min; Oh, Joo Han

    2017-12-01

    Few comparative studies have reported on the use of biologic grafts for irreparable massive rotator cuff tears. The purpose of this study was to assess the results of arthroscopic bridging graft in irreparable massive rotator cuff tears using an autogenic long head of biceps tendon (LHBT) or an allogenic dermal patch (ADP). We retrospectively reviewed 24 patients treated using the LHBT (group I) and eight patients with complete rupture of the LHBT treated using an ADP (group II) since 2011. Preoperative Goutallier's fatty degeneration, range of motion (ROM), visual analogue scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score were assessed and healing failure was evaluated at 1 year after surgery by ultrasonography or magnetic resonance imaging. The mean fatty degeneration in groups I and II was 3.9 and 3.6 for the supraspinatus ( p = 0.288), 2.7 and 2.9 for the infraspinatus ( p = 0.685), 0.9 and 1.3 for the subscapularis ( p = 0.314), and 1.3 and 3.0 for the teres minor ( p = 0.005), respectively. Subscapularis tears were found in 8 patients (33.3%) in group I and in 7 patients (87.5%) in group II ( p = 0.023). Mean ROMs and functional scores improved significantly in group I (forward flexion: 121.7° to 153.3°, p = 0.010; external rotation: 32.7° to 52.7°, p = 0.001; external rotation at 90°: 63.3° to 74.5°, p = 0.031; internal rotation: T10.5 to T9.3, p = 0.045; VAS: 7.0 to 1.1, p rotator cuff tears, especially in patients with severe fatty degeneration in the teres minor or combined biceps and subscapularis tears.

  7. A Modified Method for Reconstruction of Chronic Rupture of the Quadriceps Tendon after Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    S Singh

    2008-11-01

    Full Text Available We describe herein a modified technique for reconstruction of chronic rupture of the quadriceps tendon in a patient with bilateral total knee replacement and distal realignment of the patella. The surgery involved the application of a Dacron graft and the ‘double eights’ technique. The patient achieved satisfactory results after surgery and we believe that this technique of reconstruction offers advantages over other methods.

  8. US of the shoulder

    International Nuclear Information System (INIS)

    Gardellin, G.; Perin, B.

    1987-01-01

    Twenty five healty people and 25 patients with shoulder pain underwent US control over a 12-month period: 24 patients with shoulder pain had rotator cuff and/or biceps tendon lesions. The US findings on rotator cuff and biceps tendon lesions are compared with those of arthrography and/or surgery (96% sensitivity). US is rapid, safe, non invasive, inexpensive and often more accurate, and its use is recommended for the routine examination of the shoulder joint insteat of arthrography

  9. Tendon Transfer Surgery

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The tendon is the strong cord at either end of a muscle that is attached to bone. Tendons , combined with ...

  10. Palmar reconstruction of the triangular fibrocartilage complex for instability of the distal radioulnar joint: a biomechanical study.

    Science.gov (United States)

    Kataoka, T; Moritomo, H; Omokawa, S; Iida, A; Wada, T; Aoki, M

    2013-06-01

    We developed a new triangular fibrocartilage complex reconstruction technique for distal radioulnar joint instability in which the palmar portion of the triangular fibrocartilage complex was predominantly reconstructed, and evaluated whether such reconstruction can restore stability of the distal radioulnar joint in seven fresh cadaver upper extremities. Distal radioulnar joint instability was induced by cutting all soft-tissue stabilizers around the distal ulna. Using a palmar approach, a palmaris longus tendon graft was sutured to the remnant of the palmar radioulnar and ulnocarpal ligaments. The graft was then passed through a bone tunnel created at the fovea and was sutured. Loads were applied to the radius, and dorsopalmar displacements of the radius relative to the ulna were measured using an electromagnetic tracking device in neutral rotation, 60° supination and 60° pronation. We compared the dorsopalmar displacements before sectioning, before reconstruction and after reconstruction. Dorsopalmar instability produced by sectioning significantly improved in all forearm positions after reconstruction.

  11. CT evaluation of extensor tendon entrapment as a complication of a distal radial fracture in a child

    International Nuclear Information System (INIS)

    Frawley, Kieran J.; Anton, Christopher G.; Zbojniewicz, Andrew M.; Cornwall, Roger

    2011-01-01

    Extensor indicis proprius (EIP) entrapment is a rare complication of a distal radial fracture. We report an 11-year-old with limited flexion of her index finger 1 year after a distal radial fracture. The utility of cross-sectional imaging in the diagnosis and preoperative planning of this complication is presented. (orig.)

  12. Proximal biceps rupture: management of an unusual injury in an arm wrestler

    OpenAIRE

    Pratt, D A; Tennent, T D

    2007-01-01

    Arm wrestling may cause unusual injuries, which may require operative repair in the sporting individual. Injury to the proximal biceps as a consequence of arm wrestling has not been reported previously. The diagnosis and treatment of a 36‐year‐old man who sustained a proximal biceps rupture while arm wrestling and his operative management are described.

  13. Anatomical study of the proximal origin of hamstring muscles.

    Science.gov (United States)

    Sato, Kengo; Nimura, Akimoto; Yamaguchi, Kumiko; Akita, Keiichi

    2012-09-01

    It is relatively well accepted that the long head of the biceps femoris and the semitendinosus both originate from the ischial tuberosity as a common tendon. However, it is also widely known that the biceps femoris is consistently injured more than the semitendinosus. The purpose of this study was to examine the origins of the hamstring muscles, to find an anatomic basis for diagnosis and treatment of injuries of the posterior thigh regions. Twenty-eight hips of fourteen adult Japanese cadavers were used in this study. In twenty hips of ten cadavers, the positional relationships among the origins on the ischial tuberosity were examined. In eight hips of four cadavers, histological examination of the origins of the hamstrings was also performed. The origin of the long head of the biceps femoris adjoined that of the semitendinosus. In the proximal regions of these muscles, the long head consisted of the tendinous part; however, the semitendinosus mainly consisted of the muscular part. Some of the fibers of the biceps tendon extended to fuse with the sacrotuberous ligament. The semimembranosus muscle broadly originated from the lateral surface of the ischial tuberosity. The origins of the long head of the biceps femoris and the semitendinosus are found to be almost independent, and the tendon of the long head is partly fused with the sacrotuberous ligament. The high incidence of injuries to the long head of the biceps femoris could be explained by these anatomical configurations.

  14. A repeated carpal tunnel syndrome due to tophaceous gout in flexor tendon

    Science.gov (United States)

    Lu, Hui; Chen, Qiang; Shen, Hui

    2017-01-01

    Abstract Rationale: Gouty tophi is a rare cause of CTS. We first report a unique case of repeated CTS with gouty tophi in flexor tendon. In the previous literature, the symptoms cases of CTS were gradually increased. Patient concerns: We report a 44-year-old male porter presented with mass on his left distal forearm combined a repeated carpal tunnel syndrome for 5 years. He felt numbness in fingers and his left palmar. The CTS symptoms had been eased through rest and dugs medication. It recurred twice. Diagnoses: Monosodium urate crystal deposits were found in surgery. Histologic findings confirmed the diagnosis of gout. Interventions: We removed partial of gouty tophus and retained the integrity of the tendon. Outcomes: Two years after the surgery, the patient had not experienced any symptom recurrence. Lessons: Early diagnosis and control of gout are necessary to avoid irreversible complications. The surgery combined with decreasing trioxypurine treatment can improve the treatment outcome of gouty tophus. PMID:28248892

  15. The Superior Labrum, Anterior-to-Posterior ’SLAP’ Lesion

    Science.gov (United States)

    2006-10-01

    motion and equal sensation bilaterally. Testing was negative for impingement, rotator cuff disease, biceps tendon pathology, acromioclavicular ...impingement syndrome, acromioclavicular joint pain, bicipital tendonitis or symptomatic shoulder instability. The original description of SLAP

  16. Lipoma arborescens of the bicipitoradial bursa

    Energy Technology Data Exchange (ETDEWEB)

    Kord Valeshabad, Ali [University of Illinois, Department of Radiology, Chicago, IL (United States); University of Illinois, Division of Interventional Radiology, Chicago, IL (United States); De la Vara, Dallas; Shamim, Ejaz; Xie, Karen L. [University of Illinois, Department of Radiology, Chicago, IL (United States); Alsadi, Alaa [University of Illinois, Department of Pathology, Chicago, IL (United States)

    2018-04-15

    Lipoma arborescens (LA) is a rare, benign articular lesion that is most commonly found within the suprapatellar recess of the knee. An extremely rare case of LA involving unilateral bicipitoradial bursa is described in this study. A 58-year-old male presented with a superficial soft mass on the volar aspect of the left forearm. The magnetic resonance imaging (MRI) examination demonstrated a lobulated complex mass containing multiple frond-like fatty nodules, along the distal biceps tendon in the bicipitoradial bursa. Ultrasound-guided biopsy of the lesion confirmed the diagnosis of LA and patient was scheduled for surgical excision. Recognizing the characteristic imaging of LA, particularly on MRI, is essential for accurate pre-procedural diagnosis. (orig.)

  17. Lipoma arborescens of the bicipitoradial bursa

    International Nuclear Information System (INIS)

    Kord Valeshabad, Ali; De la Vara, Dallas; Shamim, Ejaz; Xie, Karen L.; Alsadi, Alaa

    2018-01-01

    Lipoma arborescens (LA) is a rare, benign articular lesion that is most commonly found within the suprapatellar recess of the knee. An extremely rare case of LA involving unilateral bicipitoradial bursa is described in this study. A 58-year-old male presented with a superficial soft mass on the volar aspect of the left forearm. The magnetic resonance imaging (MRI) examination demonstrated a lobulated complex mass containing multiple frond-like fatty nodules, along the distal biceps tendon in the bicipitoradial bursa. Ultrasound-guided biopsy of the lesion confirmed the diagnosis of LA and patient was scheduled for surgical excision. Recognizing the characteristic imaging of LA, particularly on MRI, is essential for accurate pre-procedural diagnosis. (orig.)

  18. Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

    DEFF Research Database (Denmark)

    Svensson, Rene Brüggebusch; Hansen, Philip; Hassenkam, Tue

    2012-01-01

    Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its...... distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n=5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young...... that of tendon supports that fibrillar rather than interfibrillar properties govern sub-failure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition...

  19. "Popeye muscle" morphology in OBPI elbow flexion contracture.

    Science.gov (United States)

    Coroneos, Christopher J; Maizlin, Zeev V; DeMatteo, Carol; Gjertsen, Deborah; Bain, James R

    2015-01-01

    The pathophysiology of elbow flexion contracture (EFC) in obstetrical brachial plexus injury (OBPI) is not established. In basic science models, neonatal denervation leads to impaired muscle growth. In clinical studies, diminished growth is correlated with extent of denervation, and improved with surgical repair. In EFC, the biceps are clinically short and round vs the contralateral size, termed the "Popeye muscle". The objective of this study was to determine if the biceps morphology (muscle belly and tendon length) in arms with EFC secondary to OBPI is different vs the contralateral. This is a retrospective matched-cohort study. Patients with unilateral EFC (>20°) secondary to OBPI were identified (median = 6.6 years, range = 4.7-16.8). A blinded radiologist used computed tomography to measure length of the biceps short head muscle belly, and tendon bilaterally using standardised anatomical landmarks. Twelve patients were analyzed. The biceps muscle belly in the injured arm was shorter in all patients vs contralateral, mean difference = 3.6 cm (80%), p muscle belly and overall length, but longer tendon vs normal. This is termed the "Popeye muscle" for its irregular morphology. Findings are consistent with impaired limb growth in denervation.

  20. Long head of biceps: from anatomy to treatment

    Directory of Open Access Journals (Sweden)

    Marco Sarmento

    2015-01-01

    Full Text Available The long head of the biceps (LHB, tendinous structure of the proximal brachial biceps, has its well-known anatomy, which contrasts with its current functional characterization. Various forms of proximal anchor and intra–articular route, important for the correct interpretation of its contribution to the pathology of the shoulder as well as the treatment methodology, are described. Knowledge of its biomechanics results mainly from cadaveric studies that contradict each other. Already the few studies in vivo indicate a depressant and stabilizing action, anterior, for the humeral head. Its pathology is rarely isolated because it is almost always correlated with rotator cuff or labrum pathology. It can be divided into 3 major groups (inflammatory, instability and traumatic and subdivided according to its location. The anterior shoulder pain is the initial symptom of pathology of LHB Its perfect characterization is dependent on the associated injuries. Clinical tests are multiple and only their combination allows better sensitivity and specificity for LHB pathology. The arthro-MRI and dynamic ultrasound are able to increase proper diagnostic of the pathology of LHB. Treatment ranges from conservative and surgical. The latter includes the repair, tenotomy and tenodesis of LHB which can be performed by open or arthroscopic methodology. The author intends to review existing literature on all aspects related to the long head of the biceps from anatomy to treatment, presenting the latest results.

  1. Achilles tendon and sports

    International Nuclear Information System (INIS)

    Ulreich, N.; Kainberger, F.; Huber, W.; Nehrer, S.

    2002-01-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [de

  2. Giant-Cell Tumor of the Distal Ulna Treated by Wide Resection and Ulnar Support Reconstruction: A Case Report

    Directory of Open Access Journals (Sweden)

    Akio Minami

    2010-01-01

    Full Text Available Giant-cell tumor of bone occurred in the distal end of the ulna is extremely uncommon. A 23-year-old male had a giant-cell tumor occurred in the distal end of the ulna. After wide resection of the distal segment of the ulna including giant-cell tumor, ulnar components of the wrist joint were reconstructed with modified Sauvé-Kapandji procedure using the iliac bone graft, preserving the triangular fibrocartilage complex and ulnar collateral ligament in order to maintain ulnar support of the wrist, and the proximal stump of the resected ulna was stabilized by tenodesis using the extensor carpi ulnaris tendon. One year after operation, the patient's wrist was pain-free and had a full range of motion. Postoperative X-rays showed no abnormal findings including recurrence of the giant-cell tumor and ulnar translation of the entire carpus. The stability of the proximal stump of the distal ulna was also maintained.

  3. Supernumerary head of biceps brachii and branching pattern of the musculocutaneous nerve

    Directory of Open Access Journals (Sweden)

    Mohan Basavaraj Angadi

    2016-01-01

    Full Text Available During routine dissection by medical undergraduates, third head of the biceps brachii muscle was found on the left side of a 75-year-old male cadaver in a total of 48 arms dissected in Department of Anatomy Armed Forces Medical College, Pune. Biceps brachii is a muscle of arm having two heads hence the name. The most frequent variation of the muscle is in the number of heads with a prevalence range of 9.1-22.9%. The origin of the supernumerary head in this case was from the humerus, between the insertion of the coracobrachialis and the upper part of the origin of the brachialis, and also from the medial intermuscular septum. The supernumerary head joined the common belly. It was supplied by the musculocutaneous nerve which after emerging from brachialis pierced it near the middle and terminated by finally supplying the biceps belly. In our study, 2.08% (1 of 48 of male cadavers were found to have the third head of biceps. The incidence of this variation can be as much as 10% as, shown in previous studies on Indian population, as reported in standard textbooks of anatomy.

  4. Adaptive tracking for pneumatic muscle actuators in bicep and tricep configurations.

    Science.gov (United States)

    Lilly, John H

    2003-09-01

    Adaptive tracking techniques are applied to pneumatic muscle actuators arranged in bicep and tricep configurations. The control objective is to force the joint angle to track a specified reference path. Mathematical models are derived for the bicep and tricep configurations. The models are nonlinear and in general time-varying, making adaptive control desirable. Stability results are derived, and the results of simulation studies are presented, contrasting the nonlinear adaptive control to a nonadaptive PID control approach.

  5. Open extensor tendon injuries: an epidemiologic study.

    Science.gov (United States)

    Patillo, Dominic; Rayan, Ghazi M

    2012-01-01

    To report the epidemiology, mechanism, anatomical location, distribution, and severity of open extensor tendon injuries in the digits, hand, and forearm as well as the frequency of associated injuries to surrounding bone and soft tissue. Retrospective chart review was conducted for patients who had operative repair of open digital extensor tendon injuries in all zones within an 11-year period. Data was grouped according to patient characteristics, zone of injury, mechanism of injury, and presence of associated injury. Statistical analysis was used to determine the presence of relevant associations. Eighty-six patients with 125 severed tendons and 105 injured digits were available for chart reviews. Patients were predominantly males (83%) with a mean age of 34.2 years and the dominant extremity was most often injured (60%). The thumb was the most commonly injured (25.7%), followed by middle finger (24.8), whereas small finger was least affected (10.5%). Sharp laceration was the most common mechanism of injury (60%), and most of these occurred at or proximal to the metacarpophalangeal joints. Most saw injuries occurred distal to the metacarpophalangeal joint. Zone V was the most commonly affected in the fingers (27%) while zone VT was the most commonly affected in the thumb (69%). Associated injuries to bone and soft tissue occurred in 46.7% of all injuries with saw and crush/avulsions being predictive of fractures and damage to the underlying joint capsule. The extensor mechanism is anatomically complex, and open injuries to the dorsum of the hand, wrist, and forearm, especially of crushing nature and those inflicted by saws, must be thoroughly evaluated. Associated injuries should be ruled out in order to customize surgical treatment and optimize outcome.

  6. Extracorporeal shockwave therapy and therapeutic exercise for supraspinatus and biceps tendinopathies in 29 dogs.

    Science.gov (United States)

    Leeman, J J; Shaw, K K; Mison, M B; Perry, J A; Carr, A; Shultz, R

    2016-10-15

    Supraspinatus tendinopathy (ST) and biceps tendinopathy (BT) are common causes of forelimb lameness in large-breed dogs and have historically been treated with conservative management or surgery. Extracorporeal shockwave therapy (ESWT) and therapeutic exercise (TE) are thought to be treatment options for these conditions. The objectives of this study were to report the clinical presentations of dogs treated with ESWT for shoulder tendinopathies, to determine the association between shoulder lesion severity identified on ultrasonography or MRI and outcome, and to compare the outcomes of dogs treated with ESWT with and without TE. Medical records of 29 dogs diagnosed with shoulder tendinopathies and treated with ESWT were reviewed, and 24 dogs were diagnosed with either unilateral BT or BT and ST. None were found to have unilateral ST. Five dogs were diagnosed with bilateral disease. Eighty-five per cent of dogs had good or excellent outcomes determined by owner assessment 11-220 weeks after therapy. Outcomes were found to be better as tendon lesion severity increased (P=0.0497), regardless if ESWT was performed with or without TE (P=0.92). ESWT should be considered a safe primary therapeutic option for canine shoulder tendinopathies. Larger controlled prospective studies are needed to adequately assess these findings. British Veterinary Association.

  7. S-dual inflation: BICEP2 data without unlikeliness

    International Nuclear Information System (INIS)

    Anchordoqui, Luis A.; Barger, Vernon; Goldberg, Haim; Huang, Xing; Marfatia, Danny

    2014-01-01

    We show that S-dual inflationary potentials solve the unlikeliness problem manifested in Planck data and explain the excess B-mode power observed by the BICEP2 experiment as arising from primordial tensor fluctuations

  8. Tendon vibration attenuates superficial venous vessel response of the resting limb during static arm exercise

    Directory of Open Access Journals (Sweden)

    Ooue Anna

    2012-11-01

    Full Text Available Abstract Background The superficial vein of the resting limb constricts sympathetically during exercise. Central command is the one of the neural mechanisms that controls the cardiovascular response to exercise. However, it is not clear whether central command contributes to venous vessel response during exercise. Tendon vibration during static elbow flexion causes primary muscle spindle afferents, such that a lower central command is required to achieve a given force without altering muscle force. The purpose of this study was therefore to investigate whether a reduction in central command during static exercise with tendon vibration influences the superficial venous vessel response in the resting limb. Methods Eleven subjects performed static elbow flexion at 35% of maximal voluntary contraction with (EX + VIB and without (EX vibration of the biceps brachii tendon. The heart rate, mean arterial pressure, and rating of perceived exertion (RPE in overall and exercising muscle were measured. The cross-sectional area (CSAvein and blood velocity of the basilic vein in the resting upper arm were assessed by ultrasound, and blood flow (BFvein was calculated using both variables. Results Muscle tension during exercise was similar between EX and EX + VIB. However, RPEs at EX + VIB were lower than those at EX (P P vein in the resting limb at EX decreased during exercise from baseline (P vein at EX + VIB did not change during exercise. CSAvein during exercise at EX was smaller than that at EX + VIB (P vein did not change during the protocol under either condition. The decreases in circulatory response and RPEs during EX + VIB, despite identical muscle tension, showed that activation of central command was less during EX + VIB than during EX. Abolishment of the decrease in CSAvein during exercise at EX + VIB may thus have been caused by a lower level of central command at EX + VIB rather than EX. Conclusion Diminished central command induced by tendon

  9. Tuberculose refratária disseminada com acometimento do tendão bicipital em paciente imunocompetente Disseminated refractary tuberculosis with biceps tendon involvement in an immunocompetent patient

    Directory of Open Access Journals (Sweden)

    Marcelo dos Reis Oliveira

    2009-06-01

    Full Text Available OBJETIVO: Relatar um caso raro de tuberculose disseminada em paciente imunocompetente, que evoluiu, durante o tratamento medicamentoso padrão, com envolvimento do tendão da porção longa do bíceps e da articulação do ombro. MÉTODOS: À primeira avaliação, o diagnóstico correto não foi feito e o paciente foi tratado com fisioterapia para tendinopatia do manguito rotador. Entretanto, apresentou rápida formação de massa na região anterior do terço proximal do braço e piora da dor. A punção da massa revelou líquido amarelado, cuja análise laboratorial confirmou tratar-se de infecção por M. tuberculosis. RESULTADOS: O paciente foi tratado com desbridamento cirúrgico e troca do esquema medicamentoso e evoluiu com resolução do quadro infeccioso e melhora completa da função do ombro direito. CONCLUSÃO: Devido a sua alta prevalência no Brasil, a tuberculose deve sempre ser considerada no diagnóstico diferencial dos casos de comprometimento crônico e progressivo das articulações, ossos, músculos, tendões e bursas, mesmo em indivíduos imunocompetentes.OBJECTIVE: The authors report a rare case of disseminated tuberculosis which had compromised the long head of biceps tendon and shoulder joint, during standard drug therapy. METHODS: On a first sight, the accurate diagnosis wasn't accomplished and the patient had been treated with physiotherapy for rotator cuff tear. However, the patient presented with a fast growing mass in anterior region of the proximal third of the arm, complaining of pain increase. Aspirative punction of the mass revealed a yellow fluid and the laboratorial analysis confirmed infection by M. Tuberculosis. The patient was treated with surgical debridement and his drug therapy was changed. RESULTS: Resolution of infectious status and complete shoulder function restoration was succeeded. CONCLUSION: Due to its high prevalence in Brazil, tuberculosis must always be considered as a possible cause of

  10. POSSIBLE ENTRAPMENT OF THE ULNAR ARTERY BY THE THIRD HEAD OF PRONATOR TERES MUSCLE. El posible atrapamiento de la arteria ulnar por el tercer fascículo del músculo pronador teres

    Directory of Open Access Journals (Sweden)

    Naveen Kumar

    2016-03-01

    Full Text Available El conocimiento de las variaciones en los alrededores de la fosa cubital es útil para cirujanos ortopédicos, cirujanos plásticos y médicos en general. Observamos las variaciones arteriales y musculares en y alrededor de la fosa cubital. La arteria braquial terminó 2 pulgadas por encima de la base de la fosa cubital. Las arterias radiales y cubitales entraron en la fosa cubital  pasando delante de los tendones de los músculos braquial y bíceps braquial respectivamente. La arteria cubital estaba rodeada por el tercer fascículo del pronador teres, que tuvo su origen en la fascia cubriendo la parte distal del músculo braquial. Este músculo se unió a tendón de pronador teres distalmente y fue suministrado por una rama del nervio mediano. Este músculo podría alterar el flujo sanguíneo en la arteria cubital y puede causar dificultades para el registro de la presión sanguínea. Knowledge of variations at and in the surroundings of cubital fossa is useful for the orthopedic surgeons, plastic surgeons and medical practitioners in general. During routine dissection, we observed arterial and muscular variations in and around the cubital fossa. The brachial artery terminated 2 inches above the base of the cubital fossa. The radial and ulnar arteries entered the cubital fossa by passing in front of the tendons of brachialis and biceps brachii respectively. The ulnar artery was surrounded by the third head of pronator teres which took its origin from the fascia covering the distal part of the brachialis muscle. This muscle joined pronator teres tendon distally and was supplied by a branch of median nerve. This muscle could alter the blood flow in the ulnar artery and may cause difficulties in recording the blood pressure.

  11. POSSIBLE ENTRAPMENT OF THE ULNAR ARTERY BY THE THIRD HEAD OF PRONATOR TERES MUSCLE. EL POSIBLE ATRAPAMIENTO DE LA ARTERIA ULNAR POR EL TERCER FASCÍCULO DEL MÚSCULO PRONADOR TERES

    Directory of Open Access Journals (Sweden)

    Satheesha Nayak B

    2012-11-01

    Full Text Available Knowledge of variations at and in the surroundings of cubital fossa is useful for the orthopedic surgeons, plastic surgeons and medical practitioners in general. During routine dissection, we observed arterial and muscular variations in and around the cubital fossa. The brachial artery terminated 2 inches above the base of the cubital fossa. The radial and ulnar arteries entered the cubital fossa by passing in front of the tendons of brachialis and biceps brachii respectively. The ulnar artery was surrounded by the third head of pronator teres which took its origin from the fascia covering the distal part of the brachialis muscle. This muscle joined pronator teres tendon distally and was supplied by a branch of median nerve. This muscle could alter the blood flow in the ulnar artery and may cause difficulties in recording the blood pressure.El conocimiento de las variaciones en los alrededores de la fosa cubital es útil para cirujanos ortopédicos, cirujanos plásticos y médicos en general. Observamos las variaciones arteriales y musculares en y alrededor de la fosa cubital. La arteria braquial terminó 2 pulgadas por encima de la base de la fosa cubital. Las arterias radiales y cubitales entraron en la fosa cubital pasando delante de los tendones de los músculos braquial y bíceps braquial respectivamente. La arteria cubital estaba rodeada por el tercer fascículo del pronador teres, que tuvo su origen en la fascia cubriendo la parte distal del músculo braquial. Este músculo se unió a tendón de pronador teres distalmente y fue suministrado por una rama del nervio mediano. Este músculo podría alterar el flujo sanguíneo en la arteria cubital y puede causar dificultades para el registro de la presión sanguínea.

  12. Calcaneal tendon: imaging findings

    International Nuclear Information System (INIS)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos

    2003-01-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  13. Containment structure tendon investigation

    International Nuclear Information System (INIS)

    Fulton, J.F.; Murray, K.H.

    1983-01-01

    The paper describes an investigation into the possible causes of lower-than-predicted tendon forces which were measured during past tendon surveillances for a concrete containment. The containment is post tensioned by vertical tendons which are anchored into a rock foundation. The tendons were originally stressed in 1969, and lift-off tests were performed on six occasions subsequent to this date over a period of 11 years. The tendon forces measured in these tests were generally lower than predicted, and by 1979 the prestress level in the containment was only marginally above the design requirement. The tendons were retensioned in 1980, and by this time an investigation into the possible causes was underway. Potential causes investigated include the rock anchors and surrounding rock, elastomeric pad creep, wire stresses, thermal effects, stressing equipment and lift-off procedures, and wire stress relaxation. The investigation activities included stress relaxation testing of wires pulled from actual tendons. The stress relaxation test program included wire specimens at several different temperature and initial stress levels and the effect of a varying temperature history on the stress relaxation property of the wires. For purpose of future force predictions of the retensioned tendons, the test program included tests to determine the effect on stress relaxation due to restressing the wires after they had relaxed for 1000 hours and 10,000 hours. (orig./GL)

  14. The boomerang flap in managing injuries of the dorsum of the distal phalanx.

    Science.gov (United States)

    Chen, S L; Chou, T D; Chen, S G; Cheng, T Y; Chen, T M; Wang, H J

    2000-09-01

    Finding an appropriate soft-tissue grafting material to close a wound located over the dorsum of a finger, especially the distal phalanx, can be a difficult task. The boomerang flap mobilized from the dorsum of the proximal phalanx of an adjacent digit can be useful when applied as an island pedicle skin flap. The vascular supply to the skin flap is derived from the retrograde perfusion of the dorsal digital artery. Mobilization and lengthening of the vascular pedicle are achieved by dividing the distal end of the dorsal metacarpal artery at the bifurcation and incorporating two adjacent dorsal digital arteries into one. The boomerang flap was used in seven individuals with injuries involving the dorsal aspect of the distal phalanx over the past year. Skin defects in all patients were combined with bone,joint, or tendon exposure. The authors found that the flap was reliable and technically simple to design and execute. This one-step procedure preserves the proper palmar digital artery to the fingertip and has proven valuable for the coverage of wide and distal defects because it has the advantages of an extended skin paddle and a lengthened vascular pedicle. When conventional local flaps are inadequate, the boomerang flap should be considered for its reliability and low associated morbidity.

  15. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  16. Reliability of biceps femoris and semitendinosus muscle architecture measurements obtained with ultrasonography

    Directory of Open Access Journals (Sweden)

    Viviane Bastos de Oliveira

    Full Text Available Introduction Currently, little attention is given to the muscle architecture reliability studies of the hamstring using a robust statistical. Our purpose was to determine the reliability of ultrasound measurements of muscle thickness, fascicle length and pennation angle of the biceps femoris and semitendinosus muscles, including heteroskedasticity and internal consistency analyses. Methods Two images of biceps femoris and semitendinosus at 50% of the thigh length were acquired from 21 volunteers, in two visits. The parameters were measured three times in each image, and for each muscle. The reliability was analyzed by the intraclass correlation coefficient (ICC and Cronbach’s alpha (αCronbach. The relative standard error of the measurements (%SEM were calculated and Bland-Altman plots were generated. Results All parameters presented excellent ICC for the three repeated measurements (ICC from 0.93 ‒ 0.99 and moderate to excellent reliability intraday (ICC from 0.70 ‒ 0.95 for both muscles. The present study indicates that ultrasound is a reliable tool to estimate the biceps femoris fascicle length (ICC = 0.97, αCronbach = 0.98, %SEM = 7.86 and semitendinosus (ICC = 0.90, αCronbach = 0.95, %SEM = 7.55, as well as the biceps femoris muscle thickness (ICC = 0.89, αCronbach = 0.94, %SEM = 10.23 and semitendinosus muscle thickness (ICC = 0.87, αCronbach = 0.93, %SEM = 1.35. At last, biceps femoris pennation angle (ICC = 0.93, αCronbach = 0.96 and %SEM = 4.36 and semitendinosus (ICC = 0.96, αCronbach = 0.98 and %SEM = 4.25 also had good repeatability. Conclusion Ultrasonography show good repeatability in estimating of muscle architecture parameters.

  17. Effect of cooling on thixotropic position-sense error in human biceps muscle.

    Science.gov (United States)

    Sekihara, Chikara; Izumizaki, Masahiko; Yasuda, Tomohiro; Nakajima, Takayuki; Atsumi, Takashi; Homma, Ikuo

    2007-06-01

    Muscle temperature affects muscle thixotropy. However, it is unclear whether changes in muscle temperature affect thixotropic position-sense errors. We studied the effect of cooling on thixotropic position-sense errors induced by short-length muscle contraction (hold-short conditioning) in the biceps of 12 healthy men. After hold-short conditioning of the right biceps muscle in a cooled (5.0 degrees C) or control (36.5 degrees C) environment, subjects perceived greater extension of the conditioned forearm at 5.0 degrees C. The angle differences between the two forearms following hold-short conditioning of the right biceps muscle in normal or cooled conditions were significantly different (-3.335 +/- 1.680 degrees at 36.5 degrees C vs. -5.317 +/- 1.096 degrees at 5.0 degrees C; P=0.043). Induction of a tonic vibration reflex in the biceps muscle elicited involuntary forearm elevation, and the angular velocities of the elevation differed significantly between arms conditioned in normal and cooled environments (1.583 +/- 0.326 degrees /s at 36.5 degrees C vs. 3.100 +/- 0.555 degrees /s at 5.0 degrees C, P=0.0039). Thus, a cooled environment impairs a muscle's ability to provide positional information, potentially leading to poor muscle performance.

  18. Structural tendon changes in patients with acromegaly: assessment of Achilles tendon with sonoelastography.

    Science.gov (United States)

    Onal, Eda Demil; Ipek, Ali; Evranos, Berna; Idilman, Ilkay Sedakat; Cakir, Bekir; Ersoy, Reyhan

    2016-03-01

    To describe the sonoelastographic appearance of the Achilles tendon in acromegalic patients and to determine whether the blood concentrations of growth hormone (GH) and insulin-like growth factor (IGF-1) are associated with the various sonographic elasticity types of Achilles tendons. Eighty-four Achilles tendons of 42 acromegaly patients and 84 Achilles tendons of 42 healthy volunteers were assessed with sonoelastography. The tendons were classified into two main types according to the elasticity features: type 1 blue/green (hard tissue) and type 2 yellow/red within green (intermediate-soft tissue). Two subtypes of these types were also defined. According to the definition, the elasticity of the tissue was in a spectrum ranging from hard to soft as the type progressed from 1a to 2b. The mean thickness of Achilles tendons in patients with acromegaly was significantly higher compared with healthy Achilles tendons (5.1+/-0.7 mm vs. 4.4+/-0.5, pacromegaly patients had type 2 sonoelastographic appearance of the Achilles tendon (124/252 third; 49.2% vs. 81/252 third; 32.1%, p=0.0001). Activity status of acromegaly and GH/IGF-I levels were similar in patients with different types of elasticity (p>0.05). Sonoelastography revealed structural changes in the tendinous tissue of patients with acromegaly, but it was not sensitive enough to reflect changes in the serum levels of GH/IGF-1.

  19. Steroid injection for painful shoulder: Usefulness of ultrasound-guided approach

    International Nuclear Information System (INIS)

    Lee, Min Hee

    2004-01-01

    To evaluate the efficacy of steroid injection into the subacromial bursa and biceps tendon sheath for painful shoulders and the usefulness of ultrasound-guided approach. Seventeen shoulders of twelve patients with shoulder pain and limited motion were included, and these patient were clinically diagnosed as a painful arc syndrome. Under ultrasound guidance, steroid injection was performed into the subacormial bursa (13 cases) and biceps tendon sheath (4 cases). In 7 cases, 1 mL of steroid was used while the remaining six patients received a mixture of 1 mL of steroid and 1 ml of lidocaine. Both shoulders of two patients received 0.5 mL of steroid. The location of needle and injection duration of fluid were continuously monitored, and complications such as leakage of steroid were recorded. Medical records were reviewed for the presence of pain relief and increasing range of motion following the injection. On ultrasonogram, the needle within the subacromial bursa and biceps tendon sheath was seen as a linear echogenic structure, and injected fluid was identified. There was neither the leakage of steroid injection nor any other complications. In 16 (94%) of 17 shoulders, there was decreased intensity of shoulder pain while increased range of motion was noted in three patients following the injection. Steroid injection into the subacormial bursa and biceps tendon sheath is effective in treating shoulder pain and limited range of motion of the shoulder, and ultrasound is useful guiding method.

  20. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  1. MR observations of long-term musculotendon remodeling following a hamstring strain injury

    International Nuclear Information System (INIS)

    Silder, Amy; Heiderscheit, Bryan C.; Thelen, Darryl G.; Enright, Timothy; Tuite, Michael J.

    2008-01-01

    The objective of this study was to use magnetic resonance (MR) imaging to investigate long-term changes in muscle and tendon morphology following a hamstring strain injury. MR images were obtained from 14 athletes who sustained a clinically diagnosed grade I-II hamstring strain injury between 5 and 23 months prior as well as five healthy controls. Qualitative bilateral comparisons were used to assess the presence of fatty infiltration and changes in morphology that may have arisen as a result of the previous injury. Hamstring muscle and tendon-scar volumes were quantified in both limbs for the biceps femoris long head (BFLH), biceps femoris short head (BFSH), the proximal semimembranosus tendon, and the proximal conjoint biceps femoris and semitendinosus tendon. Differences in muscle and tendon volume between limbs were statistically compared between the previously injured and healthy control subjects. Increased low-intensity signal was present along the musculotendon junction adjacent to the site of presumed prior injury for 11 of the 14 subjects, suggestive of persistent scar tissue. The 13 subjects with biceps femoris injuries displayed a significant decrease in BFLH volume (p < 0.01), often accompanied by an increase in BFSH volume. Two of these subjects also presented with fatty infiltration within the previously injured BFLH. The results of this study provide evidence of long-term musculotendon remodeling following a hamstring strain injury. Additionally, many athletes are likely returning to sport with residual atrophy of the BFLH and/or hypertrophy of the BFSH. It is possible that long-term changes in musculotendon structure following injury alters contraction mechanics during functional movement, such as running and may contribute to reinjury risk. (orig.)

  2. MR observations of long-term musculotendon remodeling following a hamstring strain injury

    Energy Technology Data Exchange (ETDEWEB)

    Silder, Amy [University of Wisconsin, Madison, WI (US). Department of Biomedical Engineering, Madison, WI (United States); Heiderscheit, Bryan C. [University of Wisconsin, Madison, WI (US). Department of Biomedical Engineering, Madison, WI (United States); University of Wisconsin, Madison, WI (US). Department of Orthopedics and Rehabilitation, Madison, WI (United States); Thelen, Darryl G. [University of Wisconsin, Madison, WI (US). Department of Biomedical Engineering, Madison, WI (United States); University of Wisconsin, Madison, WI (US). Department of Orthopedics and Rehabilitation, Madison, WI (United States); University of Wisconsin, Madison, WI (US). Department of Mechanical Engineering, Madison, WI (United States); Enright, Timothy; Tuite, Michael J. [University of Wisconsin, Madison, WI (United States). Department of Radiology

    2008-12-15

    The objective of this study was to use magnetic resonance (MR) imaging to investigate long-term changes in muscle and tendon morphology following a hamstring strain injury. MR images were obtained from 14 athletes who sustained a clinically diagnosed grade I-II hamstring strain injury between 5 and 23 months prior as well as five healthy controls. Qualitative bilateral comparisons were used to assess the presence of fatty infiltration and changes in morphology that may have arisen as a result of the previous injury. Hamstring muscle and tendon-scar volumes were quantified in both limbs for the biceps femoris long head (BFLH), biceps femoris short head (BFSH), the proximal semimembranosus tendon, and the proximal conjoint biceps femoris and semitendinosus tendon. Differences in muscle and tendon volume between limbs were statistically compared between the previously injured and healthy control subjects. Increased low-intensity signal was present along the musculotendon junction adjacent to the site of presumed prior injury for 11 of the 14 subjects, suggestive of persistent scar tissue. The 13 subjects with biceps femoris injuries displayed a significant decrease in BFLH volume (p < 0.01), often accompanied by an increase in BFSH volume. Two of these subjects also presented with fatty infiltration within the previously injured BFLH. The results of this study provide evidence of long-term musculotendon remodeling following a hamstring strain injury. Additionally, many athletes are likely returning to sport with residual atrophy of the BFLH and/or hypertrophy of the BFSH. It is possible that long-term changes in musculotendon structure following injury alters contraction mechanics during functional movement, such as running and may contribute to reinjury risk. (orig.)

  3. Novel methods for tendon investigations

    DEFF Research Database (Denmark)

    Kjær, Michael; Langberg, Henning; Bojsen-Møller, J.

    2008-01-01

    Purpose. Tendon structures have been studied for decades, but over the last decade, methodological development and renewed interest for metabolic, circulatory and tissue protein turnover in tendon tissue has resulted in a rising amount of investigations. Method. This paper will detail the various...... modern investigative techniques available to study tendons. Results. There are a variety of investigative methods available to study the correlations between mechanics and biology in tendons. Conclusion. The available methodologies not only allow for potential insight into physiological...... and pathophysiological mechanisms in tendon tissue, but also, to some extent, allow for more elaborate studies of the intact human tendon. Read More: http://informahealthcare.com/doi/full/10.1080/09638280701785403...

  4. Subluxation of the peroneus long tendon in the cuboid tunnel: is it normal or pathologic? An ultrasound and magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Taylor J. [Charlotte Radiology, Charlotte, NC (United States); Rosenberg, Zehava S.; Ciavarra, Gina; Bencardino, Jenny T. [New York Langone Medical Center / Hospital for Joint Diseases, New York, NY (United States); Velez, Zoraida Restrepo [Cedimed-Dinamica, Medellin (Colombia); Prost, Roberto [Marino Hospital ASL Cagliari, Cagliari (Italy)

    2016-03-15

    To evaluate the position of the peroneus longus (PL) tendon relative to the cuboid tuberosity and cuboid tunnel during ankle dorsiflexion and plantarflexion using ultrasound and MRI. The study population included two groups: 20 feet of 10 asymptomatic volunteers who underwent prospective dynamic ultrasound and 55 ankles found through retrospective review of routine ankle MRI examinations. The location of the PL tendon at the cuboid tuberosity and cuboid tunnel was designated as completely within the tunnel, indeterminate, or subluxed with respect to ankle dorsiflexion and plantarflexion. On dynamic ultrasound, the PL tendon was perched plantar to the cuboid tuberosity in dorsiflexion, and glided to enter the cuboid tunnel distal to the tuberosity in plantarflexion in all 20 feet. On the MRI evaluation, there was a statistically significant difference (p = 0.0006) in the location of the PL tendon between the ankles scanned in dorsiflexion and plantarflexion. Based on our findings on ultrasound and MRI, the PL tendon can glide in and out of the cuboid tunnel along the cuboid tuberosity depending on ankle position. Thus, ''subluxation'' of the tendon as it curves to enter the cuboid tunnel, which to the best of our knowledge has not yet been described, should be recognized as a normal, position-dependent phenomenon and not be reported as pathology. (orig.)

  5. Subluxation of the peroneus long tendon in the cuboid tunnel: is it normal or pathologic? An ultrasound and magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Stone, Taylor J.; Rosenberg, Zehava S.; Ciavarra, Gina; Bencardino, Jenny T.; Velez, Zoraida Restrepo; Prost, Roberto

    2016-01-01

    To evaluate the position of the peroneus longus (PL) tendon relative to the cuboid tuberosity and cuboid tunnel during ankle dorsiflexion and plantarflexion using ultrasound and MRI. The study population included two groups: 20 feet of 10 asymptomatic volunteers who underwent prospective dynamic ultrasound and 55 ankles found through retrospective review of routine ankle MRI examinations. The location of the PL tendon at the cuboid tuberosity and cuboid tunnel was designated as completely within the tunnel, indeterminate, or subluxed with respect to ankle dorsiflexion and plantarflexion. On dynamic ultrasound, the PL tendon was perched plantar to the cuboid tuberosity in dorsiflexion, and glided to enter the cuboid tunnel distal to the tuberosity in plantarflexion in all 20 feet. On the MRI evaluation, there was a statistically significant difference (p = 0.0006) in the location of the PL tendon between the ankles scanned in dorsiflexion and plantarflexion. Based on our findings on ultrasound and MRI, the PL tendon can glide in and out of the cuboid tunnel along the cuboid tuberosity depending on ankle position. Thus, ''subluxation'' of the tendon as it curves to enter the cuboid tunnel, which to the best of our knowledge has not yet been described, should be recognized as a normal, position-dependent phenomenon and not be reported as pathology. (orig.)

  6. Tendon 'turnover lengthening' technique.

    Science.gov (United States)

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  7. Effect of Tendon Vibration on Hemiparetic Arm Stability in Unstable Workspaces.

    Directory of Open Access Journals (Sweden)

    Megan O Conrad

    Full Text Available Sensory stimulation of wrist musculature can enhance stability in the proximal arm and may be a useful therapy aimed at improving arm control post-stroke. Specifically, our prior research indicates tendon vibration can enhance stability during point-to-point arm movements and in tracking tasks. The goal of the present study was to investigate the influence of forearm tendon vibration on endpoint stability, measured at the hand, immediately following forward arm movements in an unstable environment. Both proximal and distal workspaces were tested. Ten hemiparetic stroke subjects and 5 healthy controls made forward arm movements while grasping the handle of a two-joint robotic arm. At the end of each movement, the robot applied destabilizing forces. During some trials, 70 Hz vibration was applied to the forearm flexor muscle tendons. 70 Hz was used as the stimulus frequency as it lies within the range of optimal frequencies that activate the muscle spindles at the highest response rate. Endpoint position, velocity, muscle activity and grip force data were compared before, during and after vibration. Stability at the endpoint was quantified as the magnitude of oscillation about the target position, calculated from the power of the tangential velocity data. Prior to vibration, subjects produced unstable, oscillating hand movements about the target location due to the applied force field. Stability increased during vibration, as evidenced by decreased oscillation in hand tangential velocity.

  8. [First treatment of distal loss of tissue on lower limbs. About 15 cases].

    Science.gov (United States)

    Marchaland, J-P; Bey, E; Paranque, A; Ollat, D; Boddaert, G; Versier, G

    2008-02-01

    Distal extremity of lower limb sustains the complications of loss of tissue: problem of coverage (cutaneous and tendon necrosis, osteoarticular infection. The whole point of the surgery is to fight against the infection by repeated debridments, against the deformations or their correction by early osteosynthesis (pins and external fixation). The coverage is very important in this treatment: either with Vacuum-Assisted Closure (VAC) and skin graft or fasciocutaneous flap. In spite of this management, the after-effects are important although the conservative treatment is the determining factor of satisfaction.

  9. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  10. Sex Hormones and Tendon

    DEFF Research Database (Denmark)

    Hansen, Mette; Kjaer, Michael

    2016-01-01

    The risk of overuse and traumatic tendon and ligament injuries differ between women and men. Part of this gender difference in injury risk is probably explained by sex hormonal differences which are specifically distinct during the sexual maturation in the teenage years and during young adulthood....... The effects of the separate sex hormones are not fully elucidated. However, in women, the presence of estrogen in contrast to very low estrogen levels may be beneficial during regular loading of the tissue or during recovering after an injury, as estrogen can enhance tendon collagen synthesis rate. Yet...... has also been linked to a reduced responsiveness to relaxin. The present chapter will focus on sex difference in tendon injury risk, tendon morphology and tendon collagen turnover, but also on the specific effects of estrogen and androgens....

  11. A repeated carpal tunnel syndrome due to tophaceous gout in flexor tendon: A case report.

    Science.gov (United States)

    Lu, Hui; Chen, Qiang; Shen, Hui

    2017-03-01

    Gouty tophi is a rare cause of CTS. We first report a unique case of repeated CTS with gouty tophi in flexor tendon. In the previous literature, the symptoms cases of CTS were gradually increased. We report a 44-year-old male porter presented with mass on his left distal forearm combined a repeated carpal tunnel syndrome for 5 years. He felt numbness in fingers and his left palmar. The CTS symptoms had been eased through rest and dugs medication. It recurred twice. Monosodium urate crystal deposits were found in surgery. Histologic findings confirmed the diagnosis of gout. We removed partial of gouty tophus and retained the integrity of the tendon. Two years after the surgery, the patient had not experienced any symptom recurrence. Early diagnosis and control of gout are necessary to avoid irreversible complications. The surgery combined with decreasing trioxypurine treatment can improve the treatment outcome of gouty tophus.

  12. Natural inflation: consistency with cosmic microwave background observations of Planck and BICEP2

    International Nuclear Information System (INIS)

    Freese, Katherine; Kinney, William H.

    2015-01-01

    Natural inflation is a good fit to all cosmic microwave background (CMB) data and may be the correct description of an early inflationary expansion of the Universe. The large angular scale CMB polarization experiment BICEP2 has announced a major discovery, which can be explained as the gravitational wave signature of inflation, at a level that matches predictions by natural inflation models. The natural inflation (NI) potential is theoretically exceptionally well motivated in that it is naturally flat due to shift symmetries, and in the simplest version takes the form V(φ) = Λ 4  [1 ± cos(Nφ/f)]. A tensor-to-scalar ratio r > 0.1 as seen by BICEP2 requires the height of any inflationary potential to be comparable to the scale of grand unification and the width to be comparable to the Planck scale. The Cosine Natural Inflation model agrees with all cosmic microwave background measurements as long as f ≥ m Pl (where m Pl  = 1.22 × 10 19  GeV) and Λ ∼ m GUT  ∼ 10 16  GeV. This paper also discusses other variants of the natural inflation scenario: we show that axion monodromy with potential V∝ φ 2/3 is inconsistent with the BICEP2 limits at the 95% confidence level, and low-scale inflation is strongly ruled out. Linear potentials V ∝ φ are inconsistent with the BICEP2 limit at the 95% confidence level, but are marginally consistent with a joint Planck/BICEP2 limit at 95%. We discuss the pseudo-Nambu Goldstone model proposed by Kinney and Mahanthappa as a concrete realization of low-scale inflation. While the low-scale limit of the model is inconsistent with the data, the large-field limit of the model is marginally consistent with BICEP2. All of the models considered predict negligible running of the scalar spectral index, and would be ruled out by a detection of running

  13. The distally-based island ulnar artery perforator flap for wrist defects

    Directory of Open Access Journals (Sweden)

    Karki Durga

    2007-01-01

    Full Text Available Background: Reconstruction of soft tissue defects around the wrist with exposed tendons, joints, nerves and bone represents a challenge to plastic surgeons, and such defects necessitate flap coverage to preserve hand functions and to protect its vital structures. We evaluated the use of a distally-based island ulnar artery perforator flap in patients with volar soft tissue defects around the wrist. Materials and Methods: Between June 2004 and June 2006, seven patients of soft tissue defects on the volar aspect of the wrist underwent distally-based island ulnar artery perforator flap. Out of seven patients, five were male and two patients were female. This flap was used in the reconstruction of the post road traffic accident defects in four patients and post electric burn defects in three patients. Flap was raised on one or two perforators and was rotated to 180°. Results: All flaps survived completely. Donor sites were closed primarily without donor site morbidity. Conclusion: The distally-based island Ulnar artery perforator flap is convenient, reliable, easy to manage and is a single-stage technique for reconstructing soft tissue defects of the volar aspect of the wrist. Early use of this flap allows preservation of vital structures, decreases morbidity and allows for early rehabilitation.

  14. Biceps brachii muscle oxygenation in electrical muscle stimulation.

    Science.gov (United States)

    Muthalib, Makii; Jubeau, Marc; Millet, Guillaume Y; Maffiuletti, Nicola A; Ferrari, Marco; Nosaka, Kazunori

    2010-09-01

    The purpose of this study was to compare between electrical muscle stimulation (EMS) and maximal voluntary (VOL) isometric contractions of the elbow flexors for changes in biceps brachii muscle oxygenation (tissue oxygenation index, TOI) and haemodynamics (total haemoglobin volume, tHb = oxygenated-Hb + deoxygenated-Hb) determined by near-infrared spectroscopy (NIRS). The biceps brachii muscle of 10 healthy men (23-39 years) was electrically stimulated at high frequency (75 Hz) via surface electrodes to evoke 50 intermittent (4-s contraction, 15-s relaxation) isometric contractions at maximum tolerated current level (EMS session). The contralateral arm performed 50 intermittent (4-s contraction, 15-s relaxation) maximal voluntary isometric contractions (VOL session) in a counterbalanced order separated by 2-3 weeks. Results indicated that although the torque produced during EMS was approximately 50% of VOL (P<0.05), there was no significant difference in the changes in TOI amplitude or TOI slope between EMS and VOL over the 50 contractions. However, the TOI amplitude divided by peak torque was approximately 50% lower for EMS than VOL (P<0.05), which indicates EMS was less efficient than VOL. This seems likely because of the difference in the muscles involved in the force production between conditions. Mean decrease in tHb amplitude during the contraction phases was significantly (P<0.05) greater for EMS than VOL from the 10th contraction onwards, suggesting that the muscle blood volume was lower in EMS than VOL. It is concluded that local oxygen demand of the biceps brachii sampled by NIRS is similar between VOL and EMS.

  15. One-stage treatment of delayed 'jersey finger' by Z-step lengthening of the flexor digitorum profundus tendon at the wrist.

    Science.gov (United States)

    Sawaya, Elias T; Choughri, Hussein; Pelissier, Philippe

    2012-02-01

    The authors report the case of a 19-year-old female with delayed presentation of a type II 'jersey finger' of the fourth dominant digit. A surgical approach was performed, revealing a retracted flexor digitorum profundus tendon within a still patent sheath. The resulting loss of tendon length overruled any possibility of direct reinsertion of the tendon. A lengthening "Z-step" tendinoplasty was then performed on the tendon at the wrist, thus enabling reinsertion at the base of the distal phalanx. The patient then underwent conventional splinting and physiotherapy. Total Active Motion was measured at 220° with a 6-month follow-up. Even though there is no clear consensus concerning management of such cases, different techniques have been described, such as one- or two-stage grafting, or tenotomy at the musculotendinous junction. Lengthening tendinoplasties have been applied by certain authors but only to the flexor pollicis longus tendon. To our knowledge, this is the only reported case of lengthening Z-step applied to a long digit for the repair of type II 'jersey finger' lesions. The satisfactory functional and cosmetic outcome encourages us to consider this one-stage technique in other select cases, in order to gather more formal evidence. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Shoulder arthrography: A study for the correlation of anatomy and radiology

    International Nuclear Information System (INIS)

    Sung, K. J.; Kim, I. Y.; Park, C. Y.

    1983-01-01

    Shoulder arthrogram and dissection in cadaver were performed for clinical application. Puncture site for contrast injection was studied. The results were as follows: 1. Shoulder joints is located above the axillar and arthrography of shoulder is a simple, safe and easily interpreted. 2. The land mark for injection is a point 1.5 cm below the tip of coracoid process and very slightly medial to it. 3. There were contrast material leak from subscapular recess and distal end of the synovial sheath surrounding the long head of the biceps tendon in normal shoulder arthrogram. 4. Synoviad cavity margin show smoothness and no abnormal filling defect. 5. There were no communication between synovial cavity and subdeltoid bursa. 6. There were no specific anatomic variation in shoulder joint

  17. Osteocalcin expressing cells from tendon sheaths in mice contribute to tendon repair by activating Hedgehog signaling

    OpenAIRE

    Wang, Yi; Zhang, Xu; Huang, Huihui; Xia, Yin; Yao, YiFei; Mak, Arthur Fuk-Tat; Yung, Patrick Shu-Hang; Chan, Kai-Ming; Wang, Li; Zhang, Chenglin; Huang, Yu; Mak, Kingston King-Lun

    2017-01-01

    Both extrinsic and intrinsic tissues contribute to tendon repair, but the origin and molecular functions of extrinsic tissues in tendon repair are not fully understood. Here we show that tendon sheath cells harbor stem/progenitor cell properties and contribute to tendon repair by activating Hedgehog signaling. We found that Osteocalcin (Bglap) can be used as an adult tendon-sheath-specific marker in mice. Lineage tracing experiments show that Bglap-expressing cells in adult sheath tissues pos...

  18. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  19. Magnetic resonance imaging appearance of the flexor carpi radialis tendon after harvest in ligamentous reconstruction tendon interposition arthroplasty

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Fish, Jon R.; Ritchie, Eric R.; Tran, Hoang N.; Ingari, John V.; Campbell, Scot E.; Grayson, David E.; Sanders, Timothy G.; Mundis, Gregory; Lehman, Thomas P.

    2006-01-01

    To determine whether the post-harvest magnetic resonance (MR) imaging appearance of flexor carpi radialis (FCR) tendons, harvested during ligamentous reconstruction tendon interposition (LRTI) of the thumb carpometacarpal (CMC) joint arthroplasty, is consistent with tendon regeneration. Operative reports and patient medical records for all patients undergoing LRTI arthroplasty between 1995 and 2003 at our institution were reviewed. MR images of the patients' forearms and wrists were obtained and interpreted by two musculoskeletal radiologists. Using the flexor carpi ulnaris (FCU) tendon as an internal standard, the extent of FCR tendon regeneration was expressed as a percentage by dividing the volume of regenerated FCR tendon by the volume of the FCU tendon. Fourteen patients who had the full thickness of the FCR tendon harvested and who were available for MR imaging were identified and included in the study. At least partial regeneration of the FCR tendon occurred in 11 of the 14 patients (79%). Of these, 2 patients (14%), demonstrated complete, or nearly complete regeneration. Partial regeneration of the FCR tendon was seen in 9 of the 14 patients (64%). In 3 patients (21%), there was no appreciable regeneration of the FCR tendon. Among patients who underwent full-thickness harvest of the FCR tendon for LRTI arthroplasty of the first CMC joint, the follow-up MR imaging appearance of the flexor carpi radialis tendon was consistent with tendon regeneration in 79% of those examined. (orig.)

  20. Clinical results of a surgical technique using endobuttons for complete tendon tear of pectoralis major muscle: report of five cases

    Directory of Open Access Journals (Sweden)

    Uchiyama Yoshiyasu

    2011-09-01

    Full Text Available Abstract Background We herein describe a surgical technique for the repair of complete tear of the pectoralis major (PM tendon using endobuttons to strengthen initial fixation. Methods Five male patients (3 judo players, 1 martial arts player, and 1 body builder were treated within 2 weeks of sustaining complete tear of the PM tendon. Average age at surgery and follow-up period were 28.4 years (range, 23-33 and 28.8 months (range, 24-36. A rectangular bone trough (about 1 × 4 cm was created on the humerus at the insertion of the distal PM tendon. The tendon stump was introduced into this trough, and fixed to the reverse side of the humeral cortex using endobuttons and non-absorbable suture. Clinical assessment of re-tear was examined by MRI. Shoulder range of motion (ROM, outcome of treatment, and isometric power were measured at final follow-up. Results There were no clinical re-tears, and MRI findings also showed continuity of the PM tendon in all cases at final follow-up. Average ROM did not differ significantly between the affected and unaffected shoulders. The clinical outcomes at final follow-up were excellent (4/5 cases or good (1/5. In addition, postoperative isometric power in horizontal flexion of the affected shoulder showed complete recovery when compared with the unaffected side. Conclusions Satisfactory outcomes could be obtained when surgery using the endobutton technique was performed within 2 weeks after complete tear of the PM tendon. Therefore, our new technique appears promising as a useful method to treat complete tear of the PM tendon.

  1. Biochemical characterisation of navicular hyaline cartilage, navicular fibrocartilage and the deep digital flexor tendon in horses with navicular disease.

    Science.gov (United States)

    Viitanen, M; Bird, J; Smith, R; Tulamo, R-M; May, S A

    2003-10-01

    The study hypothesis was that navicular disease is a process analogous to degenerative joint disease, which leads to changes in navicular fibrocartilage and in deep digital flexor tendon (DDFT) matrix composition and that the process extends to the adjacent distal interphalangeal joint. The objectives were to compare the biochemical composition of the navicular articular and palmar cartilages from 18 horses with navicular disease with 49 horses with no history of front limb lameness, and to compare navicular fibrocartilage with medial meniscus of the stifle and collateral cartilage of the hoof. Cartilage oligomeric matrix protein (COMP), deoxyribonucleic acid (DNA), total glycosaminoglycan (GAG), metalloproteinases MMP-2 and MMP-9 and water content in tissues were measured. Hyaline cartilage had the highest content of COMP and COMP content in hyaline cartilage and tendon was higher in lame horses than in sound horses (phyaline cartilage was higher in lame horses than in sound horses. The MMP-2 amounts were significantly higher in tendons compared to other tissue types. Overall, 79% of the lame horses with lesions had MMP-9 in their tendons and the amount was higher than in sound horses (phyaline and fibrocartilage as well as the DDFT with potential implications for the pathogenesis and management of the condition.

  2. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    Science.gov (United States)

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  3. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P 0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  4. Extensor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Extensor Tendon Injuries Email to a friend * required ...

  5. Magnetotherapy: The quest for tendon regeneration.

    Science.gov (United States)

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  6. Distribution of skeletal muscle involvement in autosomal recessive distal muscular dystrophy. A clinical and computed tomographic study

    Energy Technology Data Exchange (ETDEWEB)

    Mizusawa, Hidehiro; Nakanishi, Takao; Kobayashi, Fumie

    1987-02-01

    Distribution of skeletal muscle involvement in 5 cases with autosomal recessive distal muscular dystrophy was studied clinically and by computed tomography (CT). Manual muscle test showed muscle involvement with a predilection for flexors in the lower leg and adductors in the thigh. Flexion and extension of the thigh and the lower leg was impaired to similar degree. In progressed cases, neck flexors and trunk muscles were also affected mildly. CT disclosed more clearly the preferential involvement of flexors in the lower leg, and involvement of both hamstrings center dot adductors group and extensors group of the thigh to similar degree. However, m. popliteus was curiously well preserved. In addition, there was a stage showing high density and hypertrophy of m. sartorius, m. gracilis, m. adductor, m. biceps femoris, m. semimenbranosus, m. semitendinosus or m. rectus femoris, which in thought to be compensatory hypertrophy. M. gluteus minimus in the pelvic girdle and m. dorsi proprii in the trunk were also liable to be affected. The CT findings are regarded as characteristic features noted clearly before muscle weakness and atrophy become apparent clinically. CT is very useful for distinguishing distal muscular dystrophy from rimmed vacuolar distal myopathy in which m. quadriceps femoris and flexors of the lower leg are usually well preserved without compensatory hypertrophy on CT.

  7. Achilles Tendon's Tear

    OpenAIRE

    F. Shahandeh

    2008-01-01

    Introduction: The achilles and plantaris tendons to-gether makeup the posterior grouptendons of ankle. Their seldom confusion in interpreting MR images of the achilles tendon. The achilles tendon should ap-pear informally straight and black on sagital T1 weighted images and on fluid sensitive images."nCase Presentation: After a heavy sport, a 55 year-old woman cannot walk with right foot."nDiscussion: The classic achilles tendon rupture occurs with forced dorsiflexion of planted foo...

  8. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  9. Optimal arm posture control and tendon traction forces of a coupled tendon-driven manipulator

    International Nuclear Information System (INIS)

    Ma, Shugen

    1997-01-01

    In this study, the optimum arm posture of a coupled tendon-driven multijoint manipulator arm (or CT Arm) at maximum payload output was derived and the corresponding tendon traction forces were also analyzed, during management of a heavy payload by the manipulator in a gravity environment. The CT Arm is special tendon traction transmission mechanism in which a pair of tendons used to drive a joint is pulled from base actuators via pulleys mounted on the base-side joints. This mechanism enables optimal utilization of the coupled drive function of tendon traction forces and thus enables the lightweight manipulator to exhibit large payload capability. The properties of the CT Arm mechanism are elucidated by the proposed optimal posture control scheme. Computer simulation was also executed to verify the validity of the proposed control scheme. (author)

  10. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  11. Insight into the pathomorphology of the distal border of the equine navicular bone

    Directory of Open Access Journals (Sweden)

    Martyna Frątczak

    2017-01-01

    Full Text Available Pathological changes of the equine navicular bone are found in a variety of forms in numerous old and also relatively young horses. Therefore, investigations on this small bone are of major practical significance. The current article presents a view of the alterations observed on the distal aspect of the bone and analyzes their origin and importance. As a result of pressure subjected by the deep digital flexor tendon and adaptive remodelling of the bone tissue, distal border of the navicular bone extends and becomes sharpened. Osseous distal border fragments may be a consequence of this phenomenon. However, the origin of fragments is also associated with the development of entheseophytes on the margins, which can result from stress induced by the distal impar sesamoid ligament. The authors are not unanimous about the clinical importance of fragments, but it seems that the most dangerous are large-sized ones, especially when occurring together with other lesions. An important issue is also the alterations of the nutrient foramina located on the distal border, due to the main role of this surface in blood supply. Changes in the size and shape of pathological synovial invaginations can be a sign of circulatory disturbances and abnormal turnover of the bone tissue. Some researchers link synovial invaginations to cases of lameness, but their importance is still enigmatic. Majority of studies focus on warmblood horses, and a lower interest in coldblood horses can be seen. Nonetheless, certain data are a strong argument that the breed and morphotype can affect the frequency of adverse changes.

  12. High-field MR imaging of the tendons

    International Nuclear Information System (INIS)

    Beltran, J.; Burk, J.M.; Herman, L.J.; Mosure, J.C.

    1987-01-01

    MR imaging was used to investigate normal anatomy and pathologic conditions of the tendons. Tendons of experimental animals, cadaver joints, normal volunteers, and patients with suspected tendon pathology were studied. Tendon anatomy is easily identified because of the hypointensity of the tendons contrasting with the hyperintendensity of the surrounding fat. Pathologic conditions including posttraumatic and postsurgical tendon rupture, peritendinous scarring, tendinitis, and tenosynovitis are well seen with MR imaging. A detailed study of normal and abnormal tendon anatomy of the finger, wrist, shoulder, knee, and ankle is displayed, including MR images, gross specimens, and line drawings

  13. Clinical aspects of tendon healing

    NARCIS (Netherlands)

    J.C.H.M. van der Meulen (Jacques)

    1974-01-01

    textabstractWe know that healing of a tendon wound takes place by an invasion of fibreblasts from the surrounding tissues; the tendon itself has no intrinsic healing capacity. lt was Potenza (1962) who proved that a traumatic suture of the tendons within their sheath is followed by disintegration of

  14. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  15. Achilles tendon healing

    International Nuclear Information System (INIS)

    Dillon, E.H.; Pope, C.F.; Barber, V.; Jokl, P.; Lynch, K.

    1990-01-01

    This paper reports on symptomatic Achilles tendon abnormalities (rupture, tendinitis) evaluated with MR imaging during the healing phase after either surgical or conservative treatment. A total of 21 patients were studied. Fifteen of 21 underwent surgery (13 tendon ruptures) and six were managed conservatively (one rupture). MR studies were obtained before treatment in 11, at 3 months in eight, at 6 months in seven, and at 12 months in 12. The 1.5-T spin-echo and gradient-echo images were correlated with clinical results, planter reflex response times, and calf force measurements. Sequential T2 times were obtained from representative levels in the tendons

  16. Characterisation of osseous bodies of the distal phalanx of foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; O'Brien, T.R.; Redden, R.F.; Stover, S.M.; Pool, R.R.

    1993-01-01

    The distal phalanx and metacarpal physis of both forelimbs of 32 Thoroughbred foals 3-32 weeks of age were radiographed to identify those limbs with osseous bodies at a palmar process (PP) of the distal phalanx. Osseous bodies (ossicles) were identified radiographically in 19% of the foals. Sixteen of the 32 foals were selected for microradiographic and histological evaluation: 6 foals with radiographic evidence of ossicles and 10 foals without. Fourteen ossicles of the PP were observed radiographically. Ossicles were either a triangular bone fragment at the palmar aspect of the distal angle of the PP, or an oblong bone fragment separated from P3 by a radiolucent line extending 1-3 cm from the incisure of the PP to the solar margin. One foal had radiographic evidence of bilateral distal metacarpal physitis. Seventeen of 35 PPs examined microradiographically were considered normal, in that the dorsal and solar cortices were thin with trabecular bone orientated parallel to the cortical surfaces, and there was a depression in the dorsal cortical surface (i.e. parietal sulcus). Abnormal microradiographic findings in the other 18 PPs included a fracture line extending from the dorsal cortical surfaces and trabecular bridging of the fracture gap. The fracture line was often continuous with the parietal sulcus. Microradiographic evidence of a fracture was found in 75% of foals evaluated. Normal histological findings in 16 PPs included thin dorsal and solar cortices with trabeculae orientated parallel to the cortical surfaces, parallel-fibred dense connective tissue attachments of the deep digital flexor tendon to the solar cortical surfaces, and a neurovascular bundle associated with the parietal sulcus

  17. The Effect of Phospholipids (Surfactant on Adhesion and Biomechanical Properties of Tendon: A Rat Achilles Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    T. Kursat Dabak

    2015-01-01

    Full Text Available Adhesion of the tendon is a major challenge for the orthopedic surgeon during tendon repair. Manipulation of biological environment is one of the concepts to prevent adhesion. Lots of biochemicals have been studied for this purpose. We aimed to determine the effect of phospholipids on adhesion and biomechanical properties of tendon in an animal tendon repair model. Seventy-two Wistar rats were divided into 4 groups. Achilles tendons of rats were cut and repaired. Phospholipids were applied at two different dosages. Tendon adhesion was determined histopathologically and biomechanical test was performed. At macroscopic evaluation of adhesion, there are statistically significant differences between multiple-dose phospholipid injection group and Control group and also hyaluronic acid group and Control group (p0.008. Ultimate strength was highest at hyaluronic acid injection group and lowest at multiple-dose phospholipid injection group. Single-dose phospholipids (surfactant application may have a beneficial effect on the tendon adhesion. Although multiple applications of phospholipids seem the most effective regime to reduce the tendon adhesion among groups, it deteriorated the biomechanical properties of tendon.

  18. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  19. Can PRP effectively treat injured tendons?

    Science.gov (United States)

    Wang, James H-C

    2014-01-01

    PRP is widely used to treat tendon and other tissue injuries in orthopaedics and sports medicine; however, the efficacy of PRP treatment on injured tendons is highly controversial. In this commentary, I reason that there are many PRP- and patient-related factors that influence the outcomes of PRP treatment on injured tendons. Therefore, more basic science studies are needed to understand the mechanism of PRP on injured tendons. Finally, I suggest that better understanding of the PRP action mechanism will lead to better use of PRP for the effective treatment of tendon injuries in clinics.

  20. Effect of Footwear Modifications on Oscillations at the Achilles Tendon during Running on a Treadmill and Over Ground: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Ilka Meinert

    Full Text Available Achilles tendon injuries are known to commonly occur in runners. During running repeated impacts are transferred in axial direction along the lower leg, therefore possibly affecting the oscillation behavior of the Achilles tendon. The purpose of the present study was to explore the effects of different footwear modifications and different ground conditions (over ground versus treadmill on oscillations at the Achilles tendon.Oscillations were measured in 20 male runners using two tri-axial accelerometers. Participants ran in three different shoe types on a treadmill and over ground. Data analysis was limited to stance phase and performed in time and frequency space. Statistical comparison was conducted between oscillations in vertical and horizontal direction, between running shoes and between ground conditions (treadmill versus over ground running.Differences in the oscillation behavior could be detected between measurement directions with peak accelerations in the vertical being lower than those in the horizontal direction, p < 0.01. Peak accelerations occurred earlier at the distal accelerometer than at the proximal one, p < 0.01. Average normalized power differed between running shoes (p < 0.01 with harder damping material resulting in higher power values. Little to no power attenuation was found between the two accelerometers. Oscillation behavior of the Achilles tendon is not influenced by ground condition.Differences in shoe configurations may lead to variations in running technique and impact forces and therefore result in alterations of the vibration behavior at the Achilles tendon. The absence of power attenuation may have been caused by either a short distance between the two accelerometers or high stiffness of the tendon. High stiffness of the tendon will lead to complete transmission of the signal along the Achilles tendon and therefore no attenuation occurs.

  1. Measuring Regional Changes in Damaged Tendon

    Science.gov (United States)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  2. Tendon sheath fibroma in the thigh.

    Science.gov (United States)

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  3. Distal nerve transfer versus supraclavicular nerve grafting: comparison of elbow flexion outcome in neonatal brachial plexus palsy with C5-C7 involvement.

    Science.gov (United States)

    Heise, Carlos O; Siqueira, Mario G; Martins, Roberto S; Foroni, Luciano H; Sterman-Neto, Hugo

    2017-09-01

    Ulnar and median nerve transfers to arm muscles have been used to recover elbow flexion in infants with neonatal brachial plexus palsy, but there is no direct outcome comparison with the classical supraclavicular nerve grafting approach. We retrospectively analyzed patients with C5-C7 neonatal brachial plexus palsy submitted to nerve surgery and recorded elbow flexion recovery using the active movement scale (0-7) at 12 and 24 months after surgery. We compared 13 patients submitted to supraclavicular nerve grafting with 21 patients submitted to distal ulnar or median nerve transfer to biceps motor branch. We considered elbow flexion scores of 6 or 7 as good results. The mean elbow flexion score and the proportion of good results were better using distal nerve transfers than supraclavicular grafting at 12 months (p nerve grafting at 12 months showed good elbow flexion recovery after ulnar nerve transfers. Distal nerve transfers provided faster elbow flexion recovery than supraclavicular nerve grafting, but there was no significant difference in the outcome after 24 months of surgery. Patients with failed supraclavicular grafting operated early can still benefit from late distal nerve transfers. Supraclavicular nerve grafting should remain as the first line surgical treatment for children with neonatal brachial plexus palsy.

  4. Quadriceps Tendon Rupture and Contralateral Patella Tendon Avulsion Post Primary Bilateral Total Knee Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma

    2016-07-01

    Full Text Available Background: Extensor mechanism failure secondary to knee replacement could be due to tibial tubercle avulsion, Patellar tendon rupture, patellar fracture or quadriceps tendon rupture. An incidence of Patella tendon rupture of 0.17% and Quadriceps tendon rupture of around 0.1% has been reported after Total knee arthroplasty. These are considered a devastating complication that substantially affects the clinical results and are challenging situations to treat with surgery being the mainstay of the treatment. Case Description: We report here an interesting case of a patellar tendon rupture of one knee and Quadriceps tendon rupture of the contralateral knee following simultaneous bilateral knee replacement in a case of inflammatory arthritis patient. End to end repair for Quadriceps tear and augmentation with Autologous Hamstring tendon graft was done for Patella tendon rupture. OUTCOME: Patient was followed up for a period of 1 year and there was no Extension lag with a flexion of 100 degrees in both the knees. DISCUSSION: The key learning points and important aspects of diagnosing these injuries early and the management techniques are described in this unique case of bilateral extensor mechanism disruption following knee replacements.

  5. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  6. Microstructural stress relaxation mechanics in functionally different tendons.

    Science.gov (United States)

    Screen, H R C; Toorani, S; Shelton, J C

    2013-01-01

    Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Strain sonoelastographic evaluation of biceps muscle intrinsic stiffness after botulinum toxin-A injection.

    Science.gov (United States)

    Aşkın, Ayhan; Kalaycı, Özlem Tuğçe; Bayram, Korhan Barış; Tosun, Aliye; Demirdal, Ümit Seçil; Atar, Emel; İnci, Mehmet Fatih

    2017-01-01

    The most commonly used clinical tools for measuring spasticity are modified Ashworth scale (MAS) and Tardieu scale but both yield subjective rather than objective results. Ultrasound elastography (EUS) provides information on tissue stiffness and allows the qualitative or quantitative measurements of the mechanical properties of tissues. To assess the stiffness of biceps brachialis muscles in stroke patients by strain EUS and to investigate the sonoelastographic changes and its correlations with clinical evaluation parameters after botulinum toxin-A (BTA) injections. This is a prospective study. A total of 48 chronic stroke patients requiring BTA injections to biceps brachialis muscles were included in the study. All patients received injections with BTA to biceps brachialis muscles under ultrasound guidance. MAS, goniometric measurements, and strain EUS assessments were performed at preintervention and at 4-week postintervention. Strain index values of biceps muscle on the affected side were significantly increased compared with those on the unaffected side (p < 0.01). At 4 weeks after BTA injection, significant improvements were observed in MAS grades and goniometric measurements (p < 0.05). Statistically significant differences were also found between the MAS grades and strain index values in both pre-/postintervention period (p < 0.01). No significant correlations were observed between clinical parameters and strain EUS findings. Strain EUS is a promising diagnostic tool for assessing stiffness in spastic muscles, in establishing the treatment plan and monitoring the effectiveness of the therapeutic modality.

  8. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  9. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  10. Tendon Force Transmission at the Nanoscale

    DEFF Research Database (Denmark)

    Svensson, René

    2013-01-01

    of connective tissue function that are poorly understood. One such aspect is the microscopic mechanisms of force transmission through tendons over macroscopic distances. Force transmission is at the heart of tendon function, but the large range of scales in the hierarchical structure of tendons has made...... it difficult to tackle. The tendon hierarchy ranges from molecules (2 nm) over fibrils (200 nm), fibers (2 μm) and fascicles (200 μm) to tendons (10 mm), and to derive the mechanisms of force transmission it is necessary to know the mechanical behavior at each hierarchical level. The aim of the present work...... was to elucidate the mechanisms of force transmission in tendons primarily by investigating the mechanical behavior at the hierarchical level of collagen fibrils. To do so we have developed an atomic force microscopy (AFM) method for tensile testing of native collagen fibrils. The thesis contains five papers...

  11. Distal median nerve dysfunction

    Science.gov (United States)

    ... later on. Inflammation of the tendons ( tendonitis ) or joints ( arthritis ) can also put pressure on the nerve. ... how fast electrical signals move through a nerve Neuromuscular ultrasound to view problems with the muscles and ...

  12. Biology and augmentation of tendon-bone insertion repair

    OpenAIRE

    Lui, PPY; Zhang, P; Chan, KM; Qin, L

    2010-01-01

    Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL) reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis") which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be ...

  13. Bone marrow-derived mesenchymal stem cells influence early tendon-healing in a rabbit achilles tendon model.

    Science.gov (United States)

    Chong, Alphonsus K S; Ang, Abel D; Goh, James C H; Hui, James H P; Lim, Aymeric Y T; Lee, Eng Hin; Lim, Beng Hai

    2007-01-01

    A repaired tendon needs to be protected for weeks until it has accrued enough strength to handle physiological loads. Tissue-engineering techniques have shown promise in the treatment of tendon and ligament defects. The present study tested the hypothesis that bone marrow-derived mesenchymal stem cells can accelerate tendon-healing after primary repair of a tendon injury in a rabbit model. Fifty-seven New Zealand White rabbits were used as the experimental animals, and seven others were used as the source of bone marrow-derived mesenchymal stem cells. The injury model was a sharp complete transection through the midsubstance of the Achilles tendon. The transected tendon was immediately repaired with use of a modified Kessler suture and a running epitendinous suture. Both limbs were used, and each side was randomized to receive either bone marrow-derived mesenchymal stem cells in a fibrin carrier or fibrin carrier alone (control). Postoperatively, the rabbits were not immobilized. Specimens were harvested at one, three, six, and twelve weeks for analysis, which included evaluation of gross morphology (sixty-two specimens), cell tracing (twelve specimens), histological assessment (forty specimens), immunohistochemistry studies (thirty specimens), morphometric analysis (forty specimens), and mechanical testing (sixty-two specimens). There were no differences between the two groups with regard to the gross morphology of the tendons. The fibrin had degraded by three weeks. Cell tracing showed that labeled bone marrow-derived mesenchymal stem cells remained viable and present in the intratendinous region for at least six weeks, becoming more diffuse at later time-periods. At three weeks, collagen fibers appeared more organized and there were better morphometric nuclear parameters in the treatment group (p tendon repair can improve histological and biomechanical parameters in the early stages of tendon-healing.

  14. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  15. DISTAL MYOPATHIES

    Science.gov (United States)

    Dimachkie, Mazen M.; Barohn, Richard J.

    2014-01-01

    Over a century ago, Gowers described two young patients in whom distal muscles weakness involved the hand, foot, sternocleidomastoid, and facial muscles in the other case the shoulder and distal leg musculature. Soon after, , similar distal myopathy cases were reported whereby the absence of sensory symptoms and of pathologic changes in the peripheral nerves and spinal cord at postmortem examination allowed differentiation from Charcot-Marie-Tooth disease. In 1951, Welander described autosomal dominant (AD) distal arm myopathy in a large Scandanavian cohort. Since then the number of well-characterized distal myopathies has continued to grow such that the distal myopathies have formed a clinically and genetically heterogeneous group of disorders. Affected kindred commonly manifest weakness that is limited to foot and toe muscles even in advanced stages of the disease, with variable mild proximal leg, distal arm, neck and laryngeal muscle involvement in selected individuals. An interesting consequence of the molecular characterization of the distal myopathies has been the recognition that mutation in a single gene can lead to more than one clinical disorder. For example, Myoshi myopathy (MM) and limb girdle muscular dystrophy (LGMD) type 2B are allelic disorders due to defects in the gene that encodes dysferlin. The six well described distal myopathy syndromes are shown in Table 1. Table 2 lists advances in our understanding of the myofibrillar myopathy group and Table 3 includes more recently delineated and less common distal myopathies. In the same manner, the first section of this review pertains to the more traditional six distal myopathies followed by discussion of the myofibrillar myopathies. In the third section, we review other clinically and genetically distinctive distal myopathy syndromes usually based upon single or smaller family cohorts. The fourth section considers other neuromuscular disorders that are important to recognize as they display prominent

  16. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    Science.gov (United States)

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  17. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  18. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  19. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  20. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    Shengkun Li

    2016-01-01

    Full Text Available The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  1. Biceps tenodesis is a viable option for salvage of failed SLAP repair.

    Science.gov (United States)

    Werner, Brian C; Pehlivan, Hakan C; Hart, Joseph M; Lyons, Matthew L; Gilmore, C Jan; Garrett, Cara B; Carson, Eric W; Diduch, David R; Miller, Mark D; Brockmeier, Stephen F

    2014-08-01

    Outcomes of arthroscopic superior labral anterior-posterior (SLAP) repairs have been well reported with generally favorable outcomes. Unfortunately, a percentage of patients remain dissatisfied or suffer further injury after SLAP repair and may seek additional treatment. The purpose of this study was to evaluate the surgical outcomes of biceps tenodesis for failed SLAP repairs. A retrospective review of all patients undergoing biceps tenodesis was completed. Inclusion criteria were previous SLAP repair and subsequent revision biceps tenodesis. Exclusion criteria were additional shoulder procedures including rotator cuff repair, instability procedures, and preoperative frozen shoulder. Objective outcomes were postoperative assessments with Constant score, American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Veterans RAND 36-Item Health Survey. Physical examination was conducted to determine postoperative range of motion and strength compared with the nonoperative shoulder. A cohort of 24 patients was identified, and of these, 17 patients (71%) completed the study at 2 years' follow-up. The average postoperative Constant score was 84.4; American Shoulder and Elbow Surgeons score, 75.5; Single Assessment Numeric Evaluation score, 73.1%; Simple Shoulder Test score, 9.2; and Veterans RAND 36-Item Health Survey score, 76.1. Postoperative range of motion of the operative shoulder returned to near that of the asymptomatic nonoperative shoulder. Workers' compensation status led to inferior results. Options for patients with a failed prior SLAP repair are limited. As a salvage operation for failed SLAP repair, biceps tenodesis serves the majority of patients well, with favorable outcomes by validated measures and excellent shoulder range of motion and elbow strength at 2 years' follow-up. Workers' compensation status may predispose patients to poorer outcomes. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board

  2. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    Science.gov (United States)

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a

  3. Biomechanical and histologic comparison of Achilles tendon ruptures reinforced with intratendinous and peritendinous plantaris tendon grafts in rabbits: an experimental study.

    Science.gov (United States)

    Ilhami, Kuru; Gokhan, Maralcan; Ulukan, Inan; Eray, Bozan M; Levent, Altinel; Ciğdem, Tokyol

    2004-11-01

    We hypothesized that the closer the reinforcing graft was to the repair zone, the more strength the healed tendon would achieved. Therefore, we compared the ruptured rabbit Achilles tendons reinforced with intratendinous and peritendinous plantaris grafts. The experimental study was performed on Achilles tendons of 20 rabbits. First, they were divided into two groups: group I (n=10) underwent intratendinous graft and end-to-end tenorraphy, and group P (n=10) were repaired end-to-end and then reinforced with a peritendinous plantaris graft. An above-knee cast was applied during 6 weeks postoperatively. The two groups were compared to each other biomechanically and histologically. Seven randomly selected rabbits from each group were used for biomechanical evaluation. The remaining six rabbits (three from each group) were used for histologic comparison. Non-operated sides (n=20) served as the control group. The mean maximum load at rupture of the repaired and control groups was 159.9+/-31 N, 83+/-7.5 N, and 207.5+/-35 N for group I, group P, and the control group, respectively. Values between groups were significantly different considering maximum load and absorbed energy to rupture. There was no significant difference between groups I and P in respect to strain. Control group tendons (groups I-C and P-C) had significantly more lengthening capability than operated tendons. Macroscopically, group I tendons were thicker and stiffer than group P tendons. Histologically, differences between the group I and group P specimens revealed that the healing process was faster in tendons augmented intratendinously. In reinforcing Achilles tendon repair, the site of the tendon graft affected the result. When the graft was used intratendinously, the healed tendon was more similar biomechanically to normal tendon and had more graft-tendon orientation histologically than the tendon augmented peritendinously.

  4. Anatomical Basis and Clinical Application of Synovial Flaps in the Wrist and Distal Forearm.

    Science.gov (United States)

    Colen, David L; Yeh, Jiun-Ting; Colen, Lawrence B

    2017-05-01

    Neuropathic symptoms after median nerve repair at the wrist or secondary to refractory carpal tunnel syndrome may become debilitating. These symptoms develop because of perineural adhesions, intraneural fibrosis, and fixation of the nerve to the transverse carpal ligament after surgery, and often require neurolysis. Interposition of vascularized soft tissue over the median nerve at the time of neurolysis prevents recurrence of such adhesions. The synovial flap, fashioned from the synovial lining of the flexor tendon sheath, is an ideal tissue for this purpose. Previous authors have described the surgical technique of the synovial flap, but the anatomical basis and design of the flap have not been previously discussed. Twenty fresh cadaver upper extremities were injected with Microfil to analyze the arterial anatomy, flap dimensions, and arc of rotation of the flexor tendon synovium mobilized as a flap suitable for coverage of the median nerve at the wrist. The authors determined that both radial and ulnar-based flaps are clinically useful for providing coverage in the wrist and distal forearm. This flap was used in 18 patients with complicated median nerve lesions in this region. All patients had an uncomplicated postoperative course. Of 13 patients treated for posttraumatic median nerve neuromas, all but two had significant resolution of symptoms. When used as a vascularized flap, the flexor tendon synovium provides adequate protection of the median nerve. Flap dimensions and vascularity of this tissue make it an ideal local flap option when performing reoperative surgery on the median nerve.

  5. Rotura del Bíceps Distal. Evaluación de resultados con técnica de doble fijación. [Distal biceps rupture: evaluation of results with double fixation technique

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Capomassi

    2013-11-01

    Full Text Available In­tro­duc­ción La rotura del bíceps distal es una lesión poco frecuente producida por la aplicación de una fuerza excéntrica sobre el codo flexionado. El objetivo de este trabajo es analizar los resultados obtenidos para la reinserción del bíceps distal mediante técnica de doble fijación con botón de anclaje cortical y tornillo interferencial de biotenodesis a través de una incisión anterior única. Materiales­ y­ Métodos Entre agosto de 2008 y febrero de 2013, registramos 19 casos de rotura del bíceps distal tratados quirúrgicamente por vía anterior limitada. Los 17 últimos casos consecutivos fueron tratados con doble fijación utilizando botón extracortical y tornillo de biotenodesis, y forman parte del estudio. Todos eran hombres, con una mediana de la edad de 41 años (rango 27-59. Los pacientes fueron evaluados con el Cuestionario DASH y el Puntaje Subjetivo/Objetivo de Andrews y Carson, y la fuerza de flexión y supinación se controló con la escala del British Medical Research Council modificada por Mackinnon y Dellon (M0-M5. Resultados El cuestionario DASH arrojó un valor mediano de 1,7 (0-5,83 y el de Andrews y Carson, de 195 (170-200 para el total; con 15 resultados excelentes y 2 buenos. Todos consiguieron una fuerza M5 para flexión y supinación de antebrazo. El seguimiento tuvo una mediana de 12 meses (4-32. En dos pacientes, se registraron complicaciones, ambas con recuperación ad íntegrum. Conclusión La técnica descrita ha demostrado ser confiable y eficaz, y permitió lograr resultados satisfactorios y una baja tasa de complicaciones.

  6. Inflation in the light of BICEP2 and PLANCK

    Indian Academy of Sciences (India)

    2016-01-13

    Jan 13, 2016 ... The BICEP2/Keck+PLANCK joint analysis of the -model polarization and polarization by foreground dust sets an upper bound on the tensor-to-scalar ratio of 0.05 < 0.12 at 95% CL. The popular Starorbinsky model Higgs-inflation or the conformally equivalent Higgs-inflation model allow low values ...

  7. Killing the straw man: Does BICEP prove inflation at the GUT scale?

    Energy Technology Data Exchange (ETDEWEB)

    Dent, James B. [Department of Physics, University of Louisiana at Lafayette, Lafayette, LA 70504 (United States); Krauss, Lawrence M. [Department of Physics and School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287 (United States); Mount Stromlo Observatory, Research School of Astronomy and Astrophysics, Australian National University, Weston, ACT, 2611 (Australia); Mathur, Harsh [Department of Physics, Case Western Reserve University, Cleveland, OH 44106-7079 (United States)

    2014-09-07

    The surprisingly large value of r, the ratio of power in tensor to scalar density perturbations in the CMB reported by the BICEP2 Collaboration, if confirmed, provides strong evidence for Inflation at the GUT scale. While the Inflationary signal remains the best motivated source, a large value of r alone would still allow for the possibility that a comparable gravitational wave background might result from a self ordering scalar field (SOSF) transition that takes place later at somewhat lower energy. We find that even without detailed considerations of the predicted BICEP signature of such a transition, simple existing limits on the isocurvature contribution to CMB anisotropies would definitively rule out a contribution of more than 5% to r≈0.2. We also present a general relation for the allowed fractional SOSF contribution to r as a function of the ultimate measured value of r. These results point strongly not only to an inflationary origin of the BICEP2 signal, if confirmed, but also to the fact that if the GUT scale is of order 10{sup 16} GeV then either the GUT transition happens before Inflation or the Inflationary transition and the GUT transition must be one and the same.

  8. Killing the straw man: Does BICEP prove inflation at the GUT scale?

    International Nuclear Information System (INIS)

    Dent, James B.; Krauss, Lawrence M.; Mathur, Harsh

    2014-01-01

    The surprisingly large value of r, the ratio of power in tensor to scalar density perturbations in the CMB reported by the BICEP2 Collaboration, if confirmed, provides strong evidence for Inflation at the GUT scale. While the Inflationary signal remains the best motivated source, a large value of r alone would still allow for the possibility that a comparable gravitational wave background might result from a self ordering scalar field (SOSF) transition that takes place later at somewhat lower energy. We find that even without detailed considerations of the predicted BICEP signature of such a transition, simple existing limits on the isocurvature contribution to CMB anisotropies would definitively rule out a contribution of more than 5% to r≈0.2. We also present a general relation for the allowed fractional SOSF contribution to r as a function of the ultimate measured value of r. These results point strongly not only to an inflationary origin of the BICEP2 signal, if confirmed, but also to the fact that if the GUT scale is of order 10 16 GeV then either the GUT transition happens before Inflation or the Inflationary transition and the GUT transition must be one and the same.

  9. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  10. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. TGIF1 Gene Silencing in Tendon-Derived Stem Cells Improves the Tendon-to-Bone Insertion Site Regeneration

    Directory of Open Access Journals (Sweden)

    Liyang Chen

    2015-11-01

    Full Text Available Background/Aims: The slow healing process of tendon-to-bone junctions can be accelerated via implanted tendon-derived stem cells (TDSCs with silenced transforming growth interacting factor 1 (TGIF1 gene. Tendon-to-bone insertion site is the special form of connective tissues derivatives of common connective progenitors, where TGF-β plays bidirectional effects (chondrogenic or fibrogenic through different signaling pathways at different stages. A recent study revealed that TGF-β directly induces the chondrogenic gene Sox9. However, TGIF1 represses the expression of the cartilage master Sox9 gene and changes its expression rate against the fibrogenesis gene Scleraxis (Scx. Methods: TGIF1 siRNA was transduced or TGIF1 was over-expressed in tendon-derived stem cells. Following suprapinatus tendon repair, rats were either treated with transduced TDSCs or nontransduced TDSCs. Histologic examination and Western blot were performed in both groups. Results: In this study, the silencing of TGIF1 significantly upregulated the chondrogenic genes and markers. Similarly, TGIF1 inhibited TDSC differentiation into cartilage via interactions with TGF-β-activated Smad2 and suppressed the phosphorylation of Smad2. The area of fibrocartilage at the tendon-bone interface was significantly increased in the TGIF1 (- group compared with the control and TGIF1-overexpressing groups in the early stages of the animal model. The interface between the tendon and bone showed a increase of new bone and fibrocartilage in the TGIF1 (- group at 4 weeks. Fibrovascular scar tissue was observed in the TGIF1-overexpressing group and the fibrin glue only group. Low levels of fibrocartilage and fibrovascular scar tissue were found in the TDSCs group. Conclusion: Collectively, this study shows that the tendon-derived stem cell modified with TGIF1 gene silencing has promising effects on tendon-to-bone healing which can be further explored as a therapeutic tool in regenerative medicine.

  12. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  13. MR Imaging and US of the Wrist Tendons.

    Science.gov (United States)

    Plotkin, Benjamin; Sampath, Srihari C; Sampath, Srinath C; Motamedi, Kambiz

    2016-10-01

    The tendons of the wrist are commonly symptomatic. They can be injured, infected, or inflamed. Magnetic resonance imaging and ultrasonography are useful tools for evaluating the wrist. Pathologic conditions of the wrist tendons include de Quervain tenosynovitis, extensor carpi ulnaris tendinopathy, rheumatoid tenosynovitis, infectious synovitis, tendon tears, hydroxyapatite deposition disease, intersection syndrome, tenosynovial giant cell tumor, and fibroma of the tendon sheath. In this article, we review the normal appearance of the wrist tendons, discuss relevant anatomy, and give an overview of common pathologic conditions affecting the wrist tendons. Online supplemental material is available for this article. © RSNA, 2016.

  14. The utility of MR imaging of the shoulder joint: comparison of the MR imaging between conventional MR imaging and arthrographic MR imaging

    International Nuclear Information System (INIS)

    Choi, Dong Sik; Ryu, Kyung Nam; Kim, Ihn Sub; Rhee, Yong Girl

    1998-01-01

    To evaluate the diagnostic value of MRI of the shoulder. Between January and June 1997, shoulder MRI and arthroscopy were performed in a total of 48 patients with shoulder pain (n=3D30) or shoulder instability (n=3D18). Forty-five were males and three were females; their ages ranged from 16 to 67 (mean 32.5) years. The period between shoulder MRI and arthroscopy was between one and 390 (mean, 42.2) days. Twenty-six patents underwent MR arthrography (AMR), and 22 conventional MRI(CMR). Each image was analyzed for rotator cuff injury, glenoid labral injury, SLAP lesion, and biceps tendon injury. On arthroscopy, one disease was found in 34 patients, two were found in six, three diseases were found in seven, and one patient had four diseases. Arthroscopic diagnosis was as follows:rotator cuff injury, 29;SLAP lesion, 12;glenoid labral injury, 10;biceps tendon injury, 4;subacromial bursitis, 2;chronic synovitis, 1;adhesive capsulitis, 1;superior glenohumeral ligament injury, 1;normal, 1. For rotator cuff injury, the sensitivity of MRI was 65.5% and specificity was 93.0% (AMR:66.7%, 95.8%, CMR:65.2%, 86.4%). For SLAP lesion, sensitivity was 58.3% and specificity was 97.2% (AMR:66.7%, 100%, CMR:50%, 93.8%);for glenoid labral injury, sensitivity was 80.0% and specificity was 89.5% (AMR:85.7%, 84.2%, CMR:66.7%, 94.7%), and for biceps tendon injury, the false negative rate was 100%. In cases involving glenoid labral injury, the diagnostic accuracy of shoulder MRI was relatively high;in rotator cuff injury and SLAP lesion, however, diagnosis was limited, and in biceps tendon injury was difficult. We suggest, however, that MR arthrography has certain diagnostic advantages over conventional MRI.=20

  15. The utility of MR imaging of the shoulder joint: comparison of the MR imaging between conventional MR imaging and arthrographic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Dong Sik; Ryu, Kyung Nam; Kim, Ihn Sub; Rhee, Yong Girl [Kyunghee Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    To evaluate the diagnostic value of MRI of the shoulder. Between January and June 1997, shoulder MRI and arthroscopy were performed in a total of 48 patients with shoulder pain (n=3D30) or shoulder instability (n=3D18). Forty-five were males and three were females; their ages ranged from 16 to 67 (mean 32.5) years. The period between shoulder MRI and arthroscopy was between one and 390 (mean, 42.2) days. Twenty-six patents underwent MR arthrography (AMR), and 22 conventional MRI(CMR). Each image was analyzed for rotator cuff injury, glenoid labral injury, SLAP lesion, and biceps tendon injury. On arthroscopy, one disease was found in 34 patients, two were found in six, three diseases were found in seven, and one patient had four diseases. Arthroscopic diagnosis was as follows:rotator cuff injury, 29;SLAP lesion, 12;glenoid labral injury, 10;biceps tendon injury, 4;subacromial bursitis, 2;chronic synovitis, 1;adhesive capsulitis, 1;superior glenohumeral ligament injury, 1;normal, 1. For rotator cuff injury, the sensitivity of MRI was 65.5% and specificity was 93.0% (AMR:66.7%, 95.8%, CMR:65.2%, 86.4%). For SLAP lesion, sensitivity was 58.3% and specificity was 97.2% (AMR:66.7%, 100%, CMR:50%, 93.8%);for glenoid labral injury, sensitivity was 80.0% and specificity was 89.5% (AMR:85.7%, 84.2%, CMR:66.7%, 94.7%), and for biceps tendon injury, the false negative rate was 100%. In cases involving glenoid labral injury, the diagnostic accuracy of shoulder MRI was relatively high;in rotator cuff injury and SLAP lesion, however, diagnosis was limited, and in biceps tendon injury was difficult. We suggest, however, that MR arthrography has certain diagnostic advantages over conventional MRI.=20.

  16. Evaluation and Management of Elbow Tendinopathy

    Science.gov (United States)

    Taylor, Samuel A.; Hannafin, Jo A.

    2012-01-01

    Context: Elbow tendinopathy is a common cause of pain and disability among patients presenting to orthopaedic surgeons, primary care physicians, physical therapists, and athletic trainers. Prompt and accurate diagnosis of these conditions facilitates a directed treatment regimen. A thorough understanding of the natural history of these injuries and treatment outcomes will enable the appropriate management of patients and their expectations. Evidence Acquisitions: The PubMed database was searched in December 2011 for English-language articles pertaining to elbow tendinopathy. Results: Epidemiologic data as well as multiple subjective and objective outcome measures were investigated to elucidate the incidence of medial epicondylitis, lateral epicondylitis, distal biceps and triceps ruptures, and the efficacy of various treatments. Conclusions: Medial and lateral epicondylitis are overuse injuries that respond well to nonoperative management. Their etiology is degenerative and related to repetitive overuse and underlying tendinopathy. Nonsteroidal anti-inflammatory drugs and localized corticosteroid injections yield moderate symptomatic relief in short term but do not demonstrate benefit on long-term follow-up. Platelet-rich plasma injections may be advantageous in cases of chronic lateral epicondylitis. If 6 to 12 months of nonoperative treatment fails, then surgical intervention can be undertaken. Distal biceps and triceps tendon ruptures, in contrast, have an acute traumatic etiology that may be superimposed on underlying tendinopathy. Prompt diagnosis and treatment improve outcomes. While partial ruptures confirmed with magnetic resonance imaging can be treated nonoperatively with immobilization, complete ruptures should be addressed with primary repair within 3 to 4 weeks of injury. PMID:23016111

  17. Repair of Achilles tendon defect with autologous ASCs engineered tendon in a rabbit model.

    Science.gov (United States)

    Deng, Dan; Wang, Wenbo; Wang, Bin; Zhang, Peihua; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin; Liu, Wei

    2014-10-01

    Adipose derived stem cells (ASCs) are an important cell source for tissue regeneration and have been demonstrated the potential of tenogenic differentiation in vitro. This study explored the feasibility of using ASCs for engineered tendon repair in vivo in a rabbit Achilles tendon model. Total 30 rabbits were involved in this study. A composite tendon scaffold composed of an inner part of polyglycolic acid (PGA) unwoven fibers and an outer part of a net knitted with PGA/PLA (polylactic acid) fibers was used to provide mechanical strength. Autologous ASCs were harvested from nuchal subcutaneous adipose tissues and in vitro expanded. The expanded ASCs were harvested and resuspended in culture medium and evenly seeded onto the scaffold in the experimental group, whereas cell-free scaffolds served as the control group. The constructs of both groups were cultured inside a bioreactor under dynamic stretch for 5 weeks. In each of 30 rabbits, a 2 cm defect was created on right side of Achilles tendon followed by the transplantation of a 3 cm cell-seeded scaffold in the experimental group of 15 rabbits, or by the transplantation of a 3 cm cell-free scaffold in the control group of 15 rabbits. Animals were sacrificed at 12, 21 and 45 weeks post-surgery for gross view, histology, and mechanical analysis. The results showed that short term in vitro culture enabled ASCs to produce matrix on the PGA fibers and the constructs showed tensile strength around 50 MPa in both groups (p > 0.05). With the increase of implantation time, cell-seeded constructs gradually form neo-tendon and became more mature at 45 weeks with histological structure similar to that of native tendon and with the presence of bipolar pattern and D-periodic structure of formed collagen fibrils. Additionally, both collagen fibril diameters and tensile strength increased continuously with significant difference among different time points (p tendon tissue with fibril structure observable only at 45 weeks

  18. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  19. Inflation in the light of BICEP2 and PLANCK

    Indian Academy of Sciences (India)

    Abstract. The BICEP2/Keck+PLANCK joint analysis of the B-model polarization and polar- ization by foreground dust sets an upper bound on the tensor-to-scalar ratio of r0.05 < 0.12 at 95%. CL. The popular Starorbinsky model Higgs-inflation or the conformally equivalent Higgs-inflation model allow low r values (∼10−3).

  20. Chaotic inflation in supergravity after Planck and BICEP2

    International Nuclear Information System (INIS)

    Kallosh, Renata; Linde, Andrei

    2014-05-01

    We discuss the general structure and observational consequences of some of the simplest versions of chaotic inflation in supergravity in relation to the data by Planck 2013 and BICEP2. We show that minimal modifications to the simplest quadratic potential are sufficient to provide a controllable tensor mode signal and a suppression of CMB power at large angular scales.

  1. Joint Analysis of BICEP2/Keck Array and Planck Data

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Ahmed, Z.

    2015-01-01

    We report the results of a joint analysis of data from BICEP2/Keck Array and Planck. BICEP2 and Keck Array have observed the same approximately 400 deg2 patch of sky centered on RA 0 h, Dec. -57.5°. The combined maps reach a depth of 57 nK deg in Stokes Q and U in a band centered at 150 GHz. Planck...... GHz to a lensed-ΛCDM model that includes dust and a possible contribution from inflationary gravitational waves (as parametrized by the tensor-to-scalar ratio r), using a prior on the frequency spectral behavior of polarized dust emission from previous Planck analysis of other regions of the sky. We...... present an alternative analysis which is similar to a map-based cleaning of the dust contribution, and show that this gives similar constraints. The final result is expressed as a likelihood curve for r, and yields an upper limit r 0.05

  2. Magnetic resonance imaging evaluation of capsulolabral tears after traumatic primary anterior shoulder dislocation. A prospective comparison with arthroscopy of 25 cases

    DEFF Research Database (Denmark)

    Suder, P.A.; Frich, Lars Henrik; Hougaard, K.

    1995-01-01

    . Subacute MRI evaluation identified 15 labral tears, 12 Hill-Sachs lesions, 1 total rotator cuff lesion, 1 partial joint side rotator cuff lesion, and 1 partial rupture of the biceps tendon. Arthroscopic examination revealed 22 labral tears, 15 Hill-Sachs lesions, 1 total rotator cuff lesion, 1 partial...... joint side rotator cuff tear, 1 partial rupture of the biceps tendon, and 1 osseous Bankart lesion. Anterior capsulolabral tears and Hill-Sachs lesions appeared with a high incidence after acute anterior primary shoulder dislocation. Conventional MRI was only moderately reliable in the preoperative...... evaluation of labral tears and Hill-Sachs lesions, and it failed to give an accurate, differentiated preoperative diagnosis of the capsulolabral lesions....

  3. Bicipitoradial Bursitis: A Review of Clinical Presentation and Treatment

    Directory of Open Access Journals (Sweden)

    Tsz-Lung Choi

    2014-06-01

    Full Text Available The bicipitoradial bursa lies at the insertion of the biceps tendon on the radial tuberosity. It is an unusual site for chronic bursitis and most often results from repetitive mechanical trauma or overuse. Other causes include tuberculosis, immunological complications of rheumatological disease and synovial chondromatosis. Accurate diagnosis requires imaging studies and sometimes histological study. It can be treated conservatively with aspiration and steroid injection. Surgical excision of the bursa is indicated in the case of infection cause, failed conservative treatment with recurrence of the enlarged bursa and pain after aspiration, presence of nerve compression with neurological impairment, mechanical limitation to flexion, and extension of the elbow or biceps tendon degeneration and/or functional impairment.

  4. Acute traumatic rupture of the patellar tendon in pediatric population: Case series and review of the literature.

    Science.gov (United States)

    Ali Yousef, Mohamed Abdelhamid; Rosenfeld, Scott

    2017-11-01

    relation to sports activities in 4 patients. Osteogenesis imperfecta and Osgood-Schlatter disease were identified in 2 patients. High riding patella is the hallmark diagnostic sign detected in plain x-ray with preoperative Insall-Salvati ratio ranged from 1.7 to 2.5. Three patients had pure soft tissue avulsion distally from the proximal tibia, 1 patient had pure soft tissue avulsion proximally from the inferior patellar pole, and 1 patient with midsubstance tendinous disruption. No associated intra-articular lesions were identified. Suture bridge double row technique, transpatellar suturing, and transosseous suturing through the proximal tibia were used for patellar tendon reinsertion. After a mean follow-up period of 18. 4 weeks (range: 10-30 weeks), patients achieved AROM ranging from 0 to 120° to 0-137° without terminal extension lag. The mean time to return to sports activity was 22 weeks (range: 13-30 weeks). Quadriceps muscle strength was 5/5 at the final follow-up visit in all patients; however, relative muscle atrophy was noted in comparison to the other side in one patient. The mean KSS was 91.8 points (range: 79-100 points) with excellent outcome in 4 patients and good outcome in 1 patient. Patellar tendon rupture is rare in the pediatric population and represents 7% of pediatric patients who sustained acute traumatic injury of the knee extensor mechanism. Ruptures may occur midsubstance, or from proximal or distal insertions. High riding patella is the hallmark diagnostic sign for such injury. Although rare, it is considered a serious injury that necessitates early diagnosis and surgical intervention. Functional range of motion was obtained in all patients with different modalities of treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Editorial Commentary: The All-Epiphyseal Anterior Cruciate Ligament Distal Femoral Approach: Sockets or Tunnels?

    Science.gov (United States)

    Cordasco, Frank A

    2018-05-01

    I believe that the distal femoral approach for anterior cruciate ligament reconstruction in the skeletally immature athlete with 3 to 6 years of remaining growth is best performed with an all-inside, all-epiphyseal technique using sockets rather than an outside-in approach creating tunnels. A shorter socket rather than a longer tunnel exposes a smaller surface area of the lateral distal femoral physis to potential compromise and resultant valgus malalignment. In addition, exiting the lateral femoral aspect of the epiphysis with a full-diameter tunnel as compared with a smaller diameter drill hole used to prepare a socket places the posterior articular cartilage, the lateral collateral ligament and anterolateral ligament footprints, and the popliteus tendon insertion at risk. My preference for sockets is also related to my belief that they provide a superior biologic milieu for graft incorporation compared with a full-length tunnel with the attendant violation of the lateral femoral cortex of the epiphysis. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Fetal development of the pulley for muscle insertion tendons: A review and new findings related to the tensor tympani tendon.

    Science.gov (United States)

    Rodríguez-Vázquez, Jose Francisco; Honkura, Yohei; Katori, Yukio; Murakami, Gen; Abe, Hiroshi

    2017-01-01

    The existence of hard tissue pulleys that act to change the direction of a muscle insertion tendon is well known in the human body. These include (1) the trochlea for the extraocular obliquus superior muscle, (2) the pterygoid hamulus for the tensor veli palatini muscle, (3) the deep sulcus on the plantar aspect of the cuboid bone for the peroneus longus tendon, (4) the lesser sciatic notch for the obturator internus muscle, and (5) the bony trochleariformis process for the tensor tympani muscle tendon. In addition, (6) the stapedius muscle tendon shows a lesser or greater angulation at the pyramidal eminence of the temporal bone. Our recent studies have shown that the development of pulleys Nos. 1 and 2 can be explained by a change in the topographical relationship between the pulley and the tendon, that of pulley No. 3 by the rapidly growing calcaneus pushing the tendon, and that of pulley No. 4 by migration of the insertion along the sciatic nerve and gluteus medius tendon. Therefore, in Nos. 1-4, an initially direct tendon curves secondarily and obtains an attachment to the pulley. In case No. 6, the terminal part of the stapedius tendon originates secondarily from the interzone mesenchymal tissue of the incudostapedial joint. In the case of pulley No. 5, we newly demonstrated that its initial phase of development was similar to No. 6, but the tensor tympani tendon achieved a right-angled turn under guidance by a specific fibrous tissue and it migrated along the growing malleus manubrium. Copyright © 2016 Elsevier GmbH. All rights reserved.

  7. Imaging the infrapatellar tendon in the elite athlete

    International Nuclear Information System (INIS)

    Peace, K.A.L.; Lee, J.C.; Healy, J.

    2006-01-01

    Extensor mechanism injuries constitute a major cause of anterior knee pain in the elite athlete. Sonography and magnetic resonance imaging (MRI) are the imaging methods of choice when assessing the infrapatellar tendon. A comprehensive imaging review of infrapatellar tendon normal anatomy, tendinopathy, and partial/full-thickness tendon tears is provided. The value of imaging the infrapatellar tendon in clinical practice, including whether sonography can predict symptoms in asymptomatic athletes, is discussed. Acute avulsion fractures, including periosteal sleeve avulsion, and chronic avulsion injuries, including Sinding-Larsen-Johansson and Osgood-Schlatter syndromes, are shown. Mimics of infrapatellar tendon pathology, including infrapatellar plica injury, patellar tendon-lateral femoral condyle friction syndrome, and Hoffa's syndrome, are illustrated

  8. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  9. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  10. Plantar tendons of the foot: MR imaging and US.

    Science.gov (United States)

    Donovan, Andrea; Rosenberg, Zehava Sadka; Bencardino, Jenny T; Velez, Zoraida Restrepo; Blonder, David B; Ciavarra, Gina A; Adler, Ronald Steven

    2013-01-01

    Tendon disorders along the plantar aspect of the foot may lead to significant symptoms but are often clinically misdiagnosed. Familiarity with the normal anatomy of the plantar tendons and its appearance at magnetic resonance (MR) imaging and ultrasonography (US) is essential for recognizing plantar tendon disorders. At MR imaging, the course of the plantar tendons is optimally visualized with dedicated imaging of the midfoot and forefoot. This imaging should include short-axis images obtained perpendicular to the long axis of the metatarsal shafts, which allows true cross-sectional evaluation of the plantar tendons. Normal plantar tendons appear as low-signal-intensity structures with all MR sequences. At US, accurate evaluation of the tendons requires that the ultrasound beam be perpendicular to the tendon. The normal tendon appears as a compact linear band of echogenic tissue that contains a fine, mixed hypoechoic and hyperechoic internal fibrillar pattern. Tendon injuries can be grouped into six major categories: tendinosis, peritendinosis, tenosynovitis, entrapment, rupture, and instability (subluxation or dislocation) and can be well assessed with both MR imaging and US. The radiologist plays an important role in the diagnosis of plantar tendon disorders, and recognizing their imaging appearances at MR imaging and US is essential.

  11. Mechanical properties of the human Achilles tendon, in vivo

    DEFF Research Database (Denmark)

    Kongsgaard, M; Nielsen, C H; Hegnsvad, S

    2011-01-01

    Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous...... junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human...

  12. A Tendon Cell Specific RNAi Screen Reveals Novel Candidates Essential for Muscle Tendon Interaction.

    Directory of Open Access Journals (Sweden)

    Prabhat Tiwari

    Full Text Available Tendons are fibrous connective tissue which connect muscles to the skeletal elements thus acting as passive transmitters of force during locomotion and provide appropriate body posture. Tendon-derived cues, albeit poorly understood, are necessary for proper muscle guidance and attachment during development. In the present study, we used dorsal longitudinal muscles of Drosophila and their tendon attachment sites to unravel the molecular nature of interactions between muscles and tendons. We performed a genetic screen using RNAi-mediated knockdown in tendon cells to find out molecular players involved in the formation and maintenance of myotendinous junction and found 21 candidates out of 2507 RNAi lines screened. Of these, 19 were novel molecules in context of myotendinous system. Integrin-βPS and Talin, picked as candidates in this screen, are known to play important role in the cell-cell interaction and myotendinous junction formation validating our screen. We have found candidates with enzymatic function, transcription activity, cell adhesion, protein folding and intracellular transport function. Tango1, an ER exit protein involved in collagen secretion was identified as a candidate molecule involved in the formation of myotendinous junction. Tango1 knockdown was found to affect development of muscle attachment sites and formation of myotendinous junction. Tango1 was also found to be involved in secretion of Viking (Collagen type IV and BM-40 from hemocytes and fat cells.

  13. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  14. Effect of estrogen on tendon collagen synthesis, tendon structural characteristics, and biomechanical properties in postmenopausal women

    DEFF Research Database (Denmark)

    Hansen, Mette; Kongsgaard, Mads; Holm, Lars

    2009-01-01

    and fibril characteristics were determined by MRI and transmission electron microscopy, whereas tendon biomechanical properties were measured during isometric maximal voluntary contraction by ultrasound recording. Tendon FSR was markedly higher in ERT-users (P

  15. Investigations related to failure of prestressing tendons

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    Kozloduy NPP units 5 and 6 containment cladding shells are prestressed by the use of tendons 450 φ 5, made of high strength wires, class B-II. The prestressing force for each tendon is 10000 kN and the calculated breakdown force - 14000 kN. There are 96 tendons in the cylindrical part of the shell and 36 ones located in the containment dome. They are located in channel forming tubes of inner diameter of 200 mm, made of dense polyethylene. In order to assure biaxial prestressed condition, the prestressing tendons are located on screw shaped lines, both left and right, with declination to the horizon 35 degrees and 15 minutes. Each prestressing tendon initially forms a knee and following the bending at elevation + 10.80 m forms the other knee, in such a way, that its two ends are anchored in one and the same area-in a common or adjacent upper anchor boxes. The prestressing tendons in the containment dome are located in two perpendicular rows. Both ends of each tendon are anchored in a common fixing, the tendon being bent to the opposite side of the dome. During construction and operation of units 5 and 6, it was found, that the design prestressing force of 10000 kN can not be reached with some tendons, due to separate wires ruptures or due to the anchoring screw spent thread. The 1992 preliminary wires tests on a failed tendon found out deformation properties, different from the systematically obtained ones for the initial steel. Taking into consideration this fact, together with the IAEA regional project, concerning WWER-1000 seismic safety and items 4 and 6 of Kozloduy NPP Technical Council decisions of 10 June 1993, brought to delegation to the Research Construction Institute the performance of the technical analysis of the applied system for shell prestressing of containments of of units 5 and 6. The analysis comprises physical-mechanical and rheological properties of the high strength wires, used for containment shell prestressing and the over all technological

  16. Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril

    DEFF Research Database (Denmark)

    Hansen, Philip; Hassenkam, Tue; Svensson, Rene Bruggebusch

    2009-01-01

    at the tendon fibril level were examined by atomic force microscopy. Peak forces increased from approximately 1379 to approximately 2622 pN while an extended Hertz fit of force-indentation data showed a approximately 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from approximately 8 MPa to approximately 39 MPa. The mechanical effects of glutaraldehyde...

  17. Biceps-Related Physical Findings Are Useful to Prevent Misdiagnosis of Cervical Spondylotic Amyotrophy as a Rotator Cuff Tear.

    Science.gov (United States)

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Yamamoto, Yusuke; Sakamoto, Yoshihiro; Koizumi, Munehisa; Tanaka, Yasuhito

    2018-02-01

    Case-control study. The aim of the present study was to identify physical findings useful for differentiating between cervical spondylotic amyotrophy (CSA) and rotator cuff tears to prevent the misdiagnosis of CSA as a rotator cuff tear. CSA and rotator cuff tears are often confused among patients presenting with difficulty in shoulder elevation. Twenty-five patients with CSA and 27 with rotator cuff tears were enrolled. We included five physical findings specific to CSA that were observed in both CSA and rotator cuff tear patients. The findings were as follows: (1) weakness of the deltoid muscle, (2) weakness of the biceps muscle, (3) atrophy of the deltoid muscle, (4) atrophy of the biceps muscle, and (5) swallow-tail sign (assessment of the posterior fibers of the deltoid). Among 25 CSA patients, 10 (40.0%) were misdiagnosed with a rotator cuff tear on initial diagnosis. The sensitivity and specificity of each physical finding were as follows: (1) deltoid weakness (sensitivity, 92.0%; specificity, 55.6%), (2) biceps weakness (sensitivity, 80.0%; specificity, 100%), (3) deltoid atrophy (sensitivity, 96.0%; specificity, 77.8%), (4) biceps atrophy (sensitivity, 88.8%; specificity, 92.6%), and (5) swallow-tail sign (sensitivity, 56.0%; specificity, 74.1%). There were statistically significant differences in each physical finding. CSA is likely to be misdiagnosed as a rotator cuff tear; however, weakness and atrophy of the biceps are useful findings for differentiating between CSA and rotator cuff tears to prevent misdiagnosis.

  18. Radiographic characteristics of the forelimb distal phalanx and microscopic morphology of the lateral palmar process in foals 3-32 weeks old

    International Nuclear Information System (INIS)

    Kaneps, A.J.; Stover, S.M.; O'Brien, T.R.; Pool, R.R.; Willits, N.H.

    1995-01-01

    Developmental morphology of the forelimb distal phalanges and lateral palmar processes of 9 Thoroughbred foals aged 3–32 weeks was assessed using radiography, microradiography and histology. For inclusion in the study, all distal phalanges had no pathologic radiographic abnormalities.Vascular channels that are characteristically found in the dorsal region of the distal phalanx were not evident radiographically in the palmar process. The proximal and distal angles of the palmar processes were separated by a lucent line continuous with the incisure in foals only through 12 weeks of age. The distal phalanges were triangular-shaped in foals 3–12 weeks of age, and were oval-shaped in older foals.The palmar aspect of the distal phalanx was the major contributor to growth of the distal phalanx in the sagittal plane, especially between 3 and 12 weeks of age. Growth of the lateral palmar process occurred through the means of endochondral ossification. The body and cortices of the lateral palmar process were composed of coarse cancellous bone. Porosity within the lateral palmar process was greater in regions sampled axial, compared to abaxial, to the parietal sulcus and did not change with age.A fracture was identified microradiographically and/or histologically in 9 of 18 (50%) and 10 of 17 (59%), respectively, of the lateral palmar processes examined. The fracture line was consistently associated with the parietal sulcus on the dorsal cortical surface and was always immediately abaxial to the deep digital flexor tendon attachment. No age-related morphological changes of the lateral palmar processes were identified with microradiography or histological examinations

  19. Numerical models for prestressing tendons in containment structures

    International Nuclear Information System (INIS)

    Kwak, Hyo-Gyoung; Kim, Jae Hong

    2006-01-01

    Two modified stress-strain relations for bonded and unbonded internal tendons are proposed. The proposed relations can simulate the post-cracking behavior and tension stiffening effect in prestressed concrete containment structures. In the case of the bonded tendon, tensile forces between adjacent cracks are transmitted from a bonded tendon to concrete by bond forces. Therefore, the constitutive law of a bonded tendon stiffened by grout needs to be determined from the bond-slip relationship. On the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. It means that the tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. In advance, the prediction of cracking behavior and ultimate resisting capacity of prestressed concrete containment structures using the introduced numerical models are succeeded, and the need for the consideration of many influencing factors such as the tension stiffening effect, plastic hinge length and modification of stress-strain relation of tendon is emphasized. Finally, the developed numerical models are applied to prestressed concrete containment structures to verify the efficiency and applicability in simulating the structural behavior with bonded and/or unbonded tendons

  20. THE ROLE OF DETRAINING IN TENDON MECHANOBIOLOGY

    Directory of Open Access Journals (Sweden)

    Antonio eFrizziero

    2016-02-01

    Full Text Available Introduction: Several conditions such as training, aging, estrogen deficiency and drugs could affect the biological and anatomo-physiological characteristics of the tendon. Additionally, recent preclinical and clinical studies examined the effect of detraining on tendon, showing alterations in its structure and morphology and in tenocyte mechanobiology. However, there is a paucity of data examining the impact that cessation of training may have on tendon. In practice, we do not fully understand how tendons respond to a period of training followed by sudden detraining. Therefore, within this review, we summarize the studies where tendon detraining was examined.Materials and methods: A descriptive systematic literature review was conducted by searching three databases (PubMed, Scopus and Web of Knowledge on tendon detraining. Original articles in English from 2000 to 2015 were included. In addition, the search was extended to the reference lists of the selected articles. A public reference manager (www.mendeley.com was used to delete duplicate articles.Results: An initial literature search yielded 134 references (www.pubmed.org: 53; www.scopus.com: 11; www.webofknowledge.com: 70. 15 publications were extracted based on the title for further analysis by two independent reviewers. Abstracts and whole articles were then reviewed to detect if they met inclusion criteria.Conclusions: The revised literature comprised 4 clinical studies and an in vitro and three in vivo reports. Overall, the results showed that tendon structure and properties after detraining are compromised, with an alteration in the tissue structural organization and mechanical properties. Clinical studies usually showed a lesser extent of tendon alterations, probably because preclinical studies permit an in-depth evaluation of tendon modifications, which is hard to perform in human subjects. In conclusion, after a period of sudden detraining (e.g. after an injury, physical activity

  1. Local trauma in human patellar tendon leads to widespread changes in the tendon gene expression

    DEFF Research Database (Denmark)

    Heinemeier, Katja Maria; Lorentzen, Marc P; Kildevang Jensen, Jacob

    2016-01-01

    Low cellular activity and slow tissue turnover in human tendon may prolong resolution of tendinopathy. This may be stimulated by moderate localized traumas such as needle penetrations, but whether this results in a widespread cellular response in tendons is unknown. In an initial hypothesis-gener...

  2. Tendon overuse syndrome: imaging diagnosis

    International Nuclear Information System (INIS)

    Huber, W.; Nehrer, S.; Muellner, T.; Kainberger, F.; Ulreich, N.; Bernhard, C.; Imhof, H.

    2001-01-01

    Injuries of muscles and tendons occur commonly during various sporting activities and in most cases the athletes feel such an accident to be sudden and unavoidable. The rupture of a tendon, however, has to be considered in many cases as the final stage of a long-standing progressive degeneration of collagen fibers. This process con be described as 'tendon overuse syndrome (TOS)'. Diagnostic imaging modalities, especially sonography and MRI, are suitable to detect and analyse the different stages of this syndrome and the degree of morphological abnormalities. The first stage is painful functional derangement, followed by tendovaginitis, peritendinitis, or bursitis. The third stage is tendinosis resulting from biomechanical or ischaemic injury of tendon fibers which may eventually be followed by partial or complete rupture. Regional or individual specifications of these four stages may occur at anatomically predisposing sites, so-called critical zones, or during periods of specific proneness, the vulnerable phases. (author)

  3. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  4. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. Venous thromboembolism rates in patients with lower limb immobilization after Achilles tendon injury are unchanged after the introduction of prophylactic aspirin: audit.

    Science.gov (United States)

    Braithwaite, I; Dunbar, L; Eathorne, A; Weatherall, M; Beasley, R

    2016-02-01

    ESSENTIALS: We audited venous thromboembolism (VTE) in Achilles injuries after the use of prophylactic aspirin. We audited 218 patients with Achilles injury requiring lower limb immobilization for ≥ 1 week. Fourteen patients (6.4%, 95% CI 3.6% to 10.5%) developed symptomatic and confirmed VTE. The incidence was similar to the 6.3% identified in the same patient group prior to the use of aspirin. We report a follow-up audit of the incidence of venous thromboembolism (VTE) in patients requiring lower limb immobilization because of Achilles tendon injury, since the introduction of a policy to routinely prescribe 100 mg of aspirin daily. We studied 218 patients aged 18-65 years who attended the Orthopaedic Assessment Unit at Wellington Hospital between January 2013 and December 2014 with Achilles tendon injury requiring lower limb immobilization for ≥ 1 week. Information on assessment of VTE risk, prescription of aspirin and symptomatic VTE occurring within 70 days of immobilization was obtained and compared with the same information collected with the same method in the same patient group between January 2006 and December 2007, before the policy to routinely prescribe aspirin was introduced. A total of 189 of 218 (93%) patients were prescribed aspirin, as compared with 0.5% previously. Fourteen patients (6.4%, 95% confidence interval 3.6-10.5%) developed symptomatic radiologically confirmed VTE (10 distal deep vein thromboses [DVTs], two proximal DVTs, one pulmonary embolism [PE], and one PE with distal DVT). Aspirin was prescribed to all patients who subsequently developed a VTE; in one of 14, a recognized risk factor was documented. The VTE incidence was similar to the 6.3% identified in the previous audit. Lower limb immobilization following Achilles tendon injury confers a high risk of VTE even with aspirin prophylaxis. Consideration should be given to prophylaxis with low molecular weight heparin during lower limb immobilization following Achilles tendon

  6. SUSY see-saw and NMSO(10)GUT inflation after BICEP2

    Indian Academy of Sciences (India)

    2016-01-13

    Jan 13, 2016 ... Recently, BICEP2, a telescope mounted at the south pole for background imaging of cosmic extragalatic polarization claimed the detection of the signal of primordial gravitational waves. The gravitational waves active during the inflationary epoch produce polarization in cosmic microwave background.

  7. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Science.gov (United States)

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  8. Accuracy of MRI technique in measuring tendon cross-sectional area

    DEFF Research Database (Denmark)

    Couppé, Christian; Svensson, R. B.; Elbrønd (Bibs), Vibeke Sødring

    2014-01-01

    , but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the patellar...... tendon CSA. Thereafter, the patellar tendon of the horse was completely dissected and embedded in an alginate cast. The CSA of the embedded tendon was measured directly by optical imaging of the cast impression. 1.5 tesla grey tendon CSA and 3 tesla grey tendon CSA were 16.5% and 13.2% lower than...... the mould tendon CSA, respectively. Also, 3 tesla tendon CSA, based on the red-green border on the National Institute of Health (NIH) colour scale, was lower than the mould tendon CSA by 2.8%. The typical error between examiners was below 2% for all the measured CSA. The typical error between examiners...

  9. The blood-tendon barrier: identification and characterisation of a novel tissue barrier in tendon blood vessels

    Directory of Open Access Journals (Sweden)

    C Lehner

    2016-05-01

    Full Text Available Tissue barriers function as “gate keepers” between different compartments (usually blood and tissue and are formed by specialised membrane-associated proteins, localising to the apicolateral plasma membrane domain of epithelial and endothelial cells. By sealing the paracellular space, the free diffusion of solutes and molecules across epithelia and endothelia is impeded. Thereby, tissue barriers contribute to the establishment and maintenance of a distinct internal and external environment, which is crucial during organ development and allows maintenance of an organ-specific homeostatic milieu. So far, various epithelial and endothelial tissue barriers have been described, including the blood-brain barrier, the blood-retina barrier, the blood-testis barrier, the blood-placenta barrier, and the cerebrospinal fluid (CSF-brain barrier, which are vital for physiological function and any disturbance of these barriers can result in severe organ damage or even death. Here, we describe the identification of a novel barrier, located in the vascular bed of tendons, which we term the blood-tendon barrier (BTB. By using immunohistochemistry, transmission electron microscopy, and tracer studies we demonstrate the presence of a functional endothelial barrier within tendons restricting the passage of large blood-borne molecules into the surrounding tendon tissue. We further provide in vitro evidence that the BTB potentially contributes to the creation of a distinct internal tissue environment impacting upon the proliferation and differentiation of tendon-resident cells, effects which might be fundamental for the onset of tendon pathologies.

  10. p38 MAPK signaling in postnatal tendon growth and remodeling.

    Directory of Open Access Journals (Sweden)

    Andrew J Schwartz

    Full Text Available Tendon is a dynamic tissue whose structure and function is influenced by mechanical loading, but little is known about the fundamental mechanisms that regulate tendon growth and remodeling in vivo. Data from cultured tendon fibroblasts indicated that the p38 MAPK pathway plays an important role in tendon fibroblast proliferation and collagen synthesis in vitro. To gain greater insight into the mechanisms of tendon growth, and explore the role of p38 MAPK signaling in this process, we tested the hypotheses that inducing plantaris tendon growth through the ablation of the synergist Achilles tendon would result in rapid expansion of a neotendon matrix surrounding the original tendon, and that treatment with the p38 MAPK inhibitor SB203580 would prevent this growth. Rats were treated with vehicle or SB203580, and subjected to synergist ablation by bilateral tenectomy of the Achilles tendon. Changes in histological and biochemical properties of plantaris tendons were analyzed 3, 7, or 28 days after overload, and comparisons were made to non-overloaded animals. By 28 days after overload, tendon mass had increased by 30% compared to non-overloaded samples, and cross-sectional area (CSA increased by around 50%, with most of the change occurring in the neotendon. The expansion in CSA initially occurred through the synthesis of a hyaluronic acid rich matrix that was progressively replaced with mature collagen. Pericytes were present in areas of active tendon growth, but never in the original tendon ECM. Inhibition of p38 MAPK resulted in a profound decrease in IL6 expression, and had a modest effect on the expression of other ECM and cell proliferation genes, but had a negligible impact on overall tendon growth. The combined results from this study provided novel insights into tendon mechanobiology, and suggest that p38 MAPK signaling does not appear to be necessary for tendon growth in vivo.

  11. Glutaraldehyde Cross-Linking of TendonMechanical Effects at the Level of the Tendon Fascicle and Fibril

    DEFF Research Database (Denmark)

    Hansen, P.; Svensson, R.B.; Aagaard, P.

    2009-01-01

    were examined by atomic force microscopy. Peak forces increased from 1379 to 2622 pN while an extended Hertz fit of force-indentation data showed a 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross-linking on the tensile properties of a single collagen fibril......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from 8 MPa to 39 MPa. The mechanical effects of glutaraldehyde at the tendon fibril level...

  12. Pathophysiology of overuse tendon injury

    International Nuclear Information System (INIS)

    Kannus, P.; Paavola, M.; Paakkala, T.; Parkkari, J.; Jaervinen, T.; Jaervinen, M.

    2002-01-01

    Overuse tendon injury is one of the most common injuries in sports.The etiology as well as the pathophysilogical mechanisms leading to tendinopathy are of crucial medical importance.At the moment intrinsic and extrinsic factors are assumed as mechanisms of overuse tendon injury. Except for the acute, extrinsic trauma, the chronic overuse tendon injury is a multifactorial process. There are many other factors, such as local hypoxia, less of nutrition, impaired metabolism and local inflammatory that may also contribute to the development of tissue damage.The exact interaction of these factors cannot be explained entirely at the moment.Further studies will be necessary in order to get more information. (orig.) [de

  13. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  14. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  15. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2017-08-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair.

  16. Texture analysis of torn rotator cuff on preoperative magnetic resonance arthrography as a predictor of postoperative tendon status

    International Nuclear Information System (INIS)

    Kang, Yeon Ah; Lee, Guen Young; Lee, Joon Woo; Lee, Eugene; Kim, Boh Young; Kim, Su Jin; Ahn, Joong Mo; Kang, Heung Sik

    2017-01-01

    To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state. Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independently the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated. Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors. Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair

  17. Gauged M-flation after BICEP2

    Science.gov (United States)

    Ashoorioon, A.; Sheikh-Jabbari, M. M.

    2014-12-01

    In view of the recent BICEP2 results [arxiv:arXiv:1403.3985] which may be attributed to the observation of B-modes polarization of the CMB with tensor-to-scalar ratio r =0.2-0.05+0.07, we revisit M-flation model. Gauged M-flation is a string theory motivated inflation model with Matrix valued scalar inflaton fields in the adjoint representation of a U (N) Yang-Mills theory. In continuation of our previous works, we show that for a class of M-flation models the action for these inflaton fields can be such that the "effective inflaton field" ϕ has a double-well Higgs-like potential, with minima at ϕ = 0 , μ. We focus on the ϕ > μ, symmetry-breaking region. We thoroughly examine predictions of the model for r in the 2σ region allowed for nS by the Planck experiment. As computed in [arxiv:arXiv:0903.1481], for Ne = 60 and nS = 0.96 we find r ≃ 0.2, which sits in the sweet spot of BICEP2 region for r. We find that with increasing μ arbitrarily, nS cannot go beyond ≃0.9670, the scalar spectral index for the quadratic chaotic potential. As nS varies in the 2σ range which is allowed by Planck and could be reached by the model, r varies in the range [ 0.13 , 0.26 ]. Future cosmological experiments, like the CMBPOL, that confines nS with σ (nS) = 0.0029 can constrain the model further. Also, in this region of potential, for nS = 0.9603, we find that the largest isocurvature mode, which is uncorrelated with curvature perturbations, has a power spectrum with the amplitude of order 10-11 at the end of inflation. We also discuss the range of predictions of r in the hilltop region, ϕ < μ.

  18. Gauged M-flation after BICEP2

    International Nuclear Information System (INIS)

    Ashoorioon, A.; Sheikh-Jabbari, M.M.

    2014-01-01

    In view of the recent BICEP2 results [ (arXiv:1403.3985)] which may be attributed to the observation of B-modes polarization of the CMB with tensor-to-scalar ratio r=0.2 −0.05 +0.07 , we revisit M-flation model. Gauged M-flation is a string theory motivated inflation model with Matrix valued scalar inflaton fields in the adjoint representation of a U(N) Yang–Mills theory. In continuation of our previous works, we show that for a class of M-flation models the action for these inflaton fields can be such that the “effective inflaton field” ϕ has a double-well Higgs-like potential, with minima at ϕ=0,μ. We focus on the ϕ>μ, symmetry-breaking region. We thoroughly examine predictions of the model for r in the 2σ region allowed for n S by the Planck experiment. As computed in [ (arXiv:0903.1481)], for N e =60 and n S =0.96 we find r≃0.2, which sits in the sweet spot of BICEP2 region for r. We find that with increasing μ arbitrarily, n S cannot go beyond ≃0.9670, the scalar spectral index for the quadratic chaotic potential. As n S varies in the 2σ range which is allowed by Planck and could be reached by the model, r varies in the range [0.13,0.26]. Future cosmological experiments, like the CMBPOL, that confines n S with σ(n S )=0.0029 can constrain the model further. Also, in this region of potential, for n S =0.9603, we find that the largest isocurvature mode, which is uncorrelated with curvature perturbations, has a power spectrum with the amplitude of order 10 −11 at the end of inflation. We also discuss the range of predictions of r in the hilltop region, ϕ<μ

  19. MRI findings associated with luxatio erecta humeri

    International Nuclear Information System (INIS)

    Krug, David K.; Vinson, Emily N.; Helms, Clyde A.

    2010-01-01

    Luxatio erecta humeri is a rare type of inferior glenohumeral dislocation with a unique radiographic appearance; however, the magnetic resonance imaging findings associated with this dislocation have not been described in the radiology literature. The purpose of this study is to identify magnetic resonance imaging findings associated with this uncommon type of glenohumeral dislocation. The magnetic resonance imaging features of four patients with clinical and radiographic evidence of luxatio erecta humeri were reviewed retrospectively by two musculoskeletal-trained radiologists. The reported mechanism of injury in all four patients was falling. The MR imaging examinations were evaluated for the presence of rotator cuff and biceps tendon pathology, glenoid labrum pathology, joint capsule and glenohumeral ligament injury, fractures and bone marrow contusions, articular cartilage injury, and joint effusions. All four patients demonstrated pathology of the glenohumeral joint. Three of the four patients demonstrated rotator cuff tears, including large full thickness tears of the supraspinatus and infraspinatus tendons in two patients, and small full thickness tear of the supraspinatus tendon with partial thickness tear of the infraspinatus tendon in the third patient. In the two patients with large full thickness tears of the supraspinatus and infraspinatus tendons, one patient demonstrated tearing of the subscapularis tendon with dislocation of a partially torn long head of the biceps tendon, and the second patient demonstrated full thickness tearing of the intra-articular biceps tendon. All four patients demonstrated injuries to the glenoid labrum and both anterior and posterior bands of the inferior glenohumeral ligament. Contusions or fractures of the humeral head were seen in two of the patients. Three of the four patients demonstrated cartilage abnormalities including a focal cartilage defect in the anterior inferior glenoid in one patient, and cartilage surface

  20. MRI findings associated with luxatio erecta humeri

    Energy Technology Data Exchange (ETDEWEB)

    Krug, David K.; Vinson, Emily N.; Helms, Clyde A. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2010-01-15

    Luxatio erecta humeri is a rare type of inferior glenohumeral dislocation with a unique radiographic appearance; however, the magnetic resonance imaging findings associated with this dislocation have not been described in the radiology literature. The purpose of this study is to identify magnetic resonance imaging findings associated with this uncommon type of glenohumeral dislocation. The magnetic resonance imaging features of four patients with clinical and radiographic evidence of luxatio erecta humeri were reviewed retrospectively by two musculoskeletal-trained radiologists. The reported mechanism of injury in all four patients was falling. The MR imaging examinations were evaluated for the presence of rotator cuff and biceps tendon pathology, glenoid labrum pathology, joint capsule and glenohumeral ligament injury, fractures and bone marrow contusions, articular cartilage injury, and joint effusions. All four patients demonstrated pathology of the glenohumeral joint. Three of the four patients demonstrated rotator cuff tears, including large full thickness tears of the supraspinatus and infraspinatus tendons in two patients, and small full thickness tear of the supraspinatus tendon with partial thickness tear of the infraspinatus tendon in the third patient. In the two patients with large full thickness tears of the supraspinatus and infraspinatus tendons, one patient demonstrated tearing of the subscapularis tendon with dislocation of a partially torn long head of the biceps tendon, and the second patient demonstrated full thickness tearing of the intra-articular biceps tendon. All four patients demonstrated injuries to the glenoid labrum and both anterior and posterior bands of the inferior glenohumeral ligament. Contusions or fractures of the humeral head were seen in two of the patients. Three of the four patients demonstrated cartilage abnormalities including a focal cartilage defect in the anterior inferior glenoid in one patient, and cartilage surface

  1. Uncovering the cellular and molecular changes in tendon stem/progenitor cells attributed to tendon aging and degeneration.

    Science.gov (United States)

    Kohler, Julia; Popov, Cvetan; Klotz, Barbara; Alberton, Paolo; Prall, Wolf Christian; Haasters, Florian; Müller-Deubert, Sigrid; Ebert, Regina; Klein-Hitpass, Ludger; Jakob, Franz; Schieker, Matthias; Docheva, Denitsa

    2013-12-01

    Although the link between altered stem cell properties and tissue aging has been recognized, the molecular and cellular processes of tendon aging have not been elucidated. As tendons contain stem/progenitor cells (TSPC), we investigated whether the molecular and cellular attributes of TSPC alter during tendon aging and degeneration. Comparing TSPC derived from young/healthy (Y-TSPC) and aged/degenerated human Achilles tendon biopsies (A-TSPC), we observed that A-TSPC exhibit a profound self-renewal and clonogenic deficits, while their multipotency was still retained. Senescence analysis showed a premature entry into senescence of the A-TSPC, a finding accompanied by an upregulation of p16(INK4A). To identify age-related molecular factors, we performed microarray and gene ontology analyses. These analyses revealed an intriguing transcriptomal shift in A-TSPC, where the most differentially expressed probesets encode for genes regulating cell adhesion, migration, and actin cytoskeleton. Time-lapse analysis showed that A-TSPC exhibit decelerated motion and delayed wound closure concomitant to a higher actin stress fiber content and a slower turnover of actin filaments. Lastly, based on the expression analyses of microarray candidates, we suggest that dysregulated cell-matrix interactions and the ROCK kinase pathway might be key players in TSPC aging. Taken together, we propose that during tendon aging and degeneration, the TSPC pool is becoming exhausted in terms of size and functional fitness. Thus, our study provides the first fundamental basis for further exploration into the molecular mechanisms behind tendon aging and degeneration as well as for the selection of novel tendon-specific therapeutical targets. © 2013 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  2. Absence of musculocutaneous nerve and accessory head of biceps brachii: a case report

    Directory of Open Access Journals (Sweden)

    Arora L

    2005-01-01

    Full Text Available During dissection of a 55-year-old female cadaver, we observed that three nerve roots contributed to the formation of Median nerve in her right upper limb. Along with this variation, absence of Musculocutaneous nerve was noticed. The muscles of front of arm i.e. Biceps Brachii, Brachialis and Coracobrachialis received their nerve supply from Median nerve. The Lateral cutaneous nerve of forearm was derived from Median nerve. Also an accessory head of Biceps Brachii muscle was present in the right arm of the same cadaver. It is extremely important to be aware of these variations while planning a surgery in the region of axilla or arm as these nerves are more liable to be injured during operations.

  3. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  4. Measurement of stress strain and vibrational properties of tendons

    Science.gov (United States)

    Revel, Gian Marco; Scalise, Alessandro; Scalise, Lorenzo

    2003-08-01

    The authors present a new non-intrusive experimental procedure based on laser techniques for the measurement of mechanical properties of tendons. The procedure is based on the measurement of the first resonance frequency of the tendon by laser Doppler vibrometry during in vitro tensile experiments, with the final aim of establishing a measurement procedure to perform the mechanical characterization of tendons by extracting parameters such as the resonance frequency, also achievable during in vivo investigation. The experimental procedure is reported, taking into account the need to simulate the physiological conditions of the Achilles tendon, and the measurement technique used for the non-invasive determination of tendon cross-sectional area during tensile vibration tests at different load levels is described. The test procedure is based on a tensile machine, which measures longitudinal tendons undergoing controlled load conditions. Cross-sectional area is measured using a new non-contact procedure for the measurement of tendon perimeter (repeatability of 99% and accuracy of 2%). For each loading condition, vibration resonance frequency and damping, cross-sectional area and tensile force are measured, allowing thus a mechanical characterization of the tendon. Tendon stress-strain curves are reported. Stress-strain curves have been correlated to the first vibration resonance frequency and damping of the tendon measured using a single-point laser Doppler vibrometer. Moreover, experimental results have been compared with a theoretical model of a vibrating cord showing discrepancies. In vitro tests are reported, demonstrating the validity of the method for the comparison of different aged rabbit tendons.

  5. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  6. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  7. Orthotopic Transplantation of Achilles Tendon Allograft in Rats: With or without Incorporation of Autologous Mesenchymal Stem Cells.

    Science.gov (United States)

    Aynardi, Michael; Zahoor, Talal; Mitchell, Reed; Loube, Jeffrey; Feltham, Tyler; Manandhar, Lumanti; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-02-01

    The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at -80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully

  8. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    Directory of Open Access Journals (Sweden)

    Mark Young

    2012-01-01

    Full Text Available Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use.

  9. Nonoperative, dynamic treatment of acute achilles tendon rupture

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Bencke, Jesper; Lauridsen, Hanne Bloch

    2015-01-01

    Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle-tendon comp......Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle...... in the terminal part of dorsiflexion was found in the non-weightbearing group. The altered stiffness and strength in the affected limb could affect the coordination of gait and running....

  10. Upper extremity injuries associated with strength training.

    Science.gov (United States)

    Haupt, H A

    2001-07-01

    Most injuries sustained during strength training are mild strains that resolve with appropriate rest. More severe injuries include traumatic shoulder dislocations, tendon ruptures of the pectoralis major, biceps, and triceps; stress fractures of the distal clavicle, humerus, radius, and ulna; traumatic fractures of the distal radius and ulna in adolescent weightlifters; and compressive and stretch neuropathies. These more severe injuries are usually the result of improperly performing a strength training exercise. Educating athletes regarding proper strength-training techniques serves to reverse established injury patterns and to prevent these injuries in the first place. Recognizing the association of anabolic steroid use to several of the injury patterns further reinforces the need for medical specialists to counsel athletes against their use. With the increasing use of supplements such as creatine, the incidence and nature of strength-training injuries may change further. Greater emphasis on the competitive performance of younger athletes undoubtedly will generate enthusiasm for strength training at earlier ages in both sexes. The importance of proper supervision of these young athletes by knowledgeable persons will increase. As the popularity of strength training grows, there will be ample opportunity to continue to catalog the injury patterns associated with this activity.

  11. Neurotization of the biceps muscle by end-to-side neurorraphy between ulnar and musculocutaneous nerves. A series of five cases.

    Science.gov (United States)

    Franciosi, L F; Modestti, C; Mueller, S F

    1998-01-01

    Three patients with avulsed C5, C6, and C7 roots and two patients with avulsed C5 and C6 roots after trauma of the brachial plexus, were treated by neurotization of the biceps using nerve fibers derived from the ulnar nerve and obtained by end-to-side neurorraphy between the ulnar and musculocutaneous nerves. The age of patients ranged from 19 to 45. The interval between the accident and surgery was 2 to 13 months. Return of biceps contraction was observed 4 to 6 months after surgery. Four patients recovered grade 4 elbow flexion. One 45-year-old patient did not obtain any biceps contraction after 9 months.

  12. Region-specific mechanical properties of the human patella tendon

    DEFF Research Database (Denmark)

    Haraldsson, B T; Aagaard, P; Krogsgaard, M

    2004-01-01

    The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig...... portion of the tendon, indicating region-specific material properties....

  13. Sensitivity of subject-specific models to Hill muscle-tendon model parameters in simulations of gait.

    Science.gov (United States)

    Carbone, V; van der Krogt, M M; Koopman, H F J M; Verdonschot, N

    2016-06-14

    Subject-specific musculoskeletal (MS) models of the lower extremity are essential for applications such as predicting the effects of orthopedic surgery. We performed an extensive sensitivity analysis to assess the effects of potential errors in Hill muscle-tendon (MT) model parameters for each of the 56 MT parts contained in a state-of-the-art MS model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (OSI), to distinguish the effect of the perturbation on the predicted force produced by the perturbed MT parts and by all the remaining MT parts, respectively, during a simulated gait cycle. Results indicated that sensitivity of the model depended on the specific role of each MT part during gait, and not merely on its size and length. Tendon slack length was the most sensitive parameter, followed by maximal isometric muscle force and optimal muscle fiber length, while nominal pennation angle showed very low sensitivity. The highest sensitivity values were found for the MT parts that act as prime movers of gait (Soleus: average OSI=5.27%, Rectus Femoris: average OSI=4.47%, Gastrocnemius: average OSI=3.77%, Vastus Lateralis: average OSI=1.36%, Biceps Femoris Caput Longum: average OSI=1.06%) and hip stabilizers (Gluteus Medius: average OSI=3.10%, Obturator Internus: average OSI=1.96%, Gluteus Minimus: average OSI=1.40%, Piriformis: average OSI=0.98%), followed by the Peroneal muscles (average OSI=2.20%) and Tibialis Anterior (average OSI=1.78%) some of which were not included in previous sensitivity studies. Finally, the proposed priority list provides quantitative information to indicate which MT parts and which MT parameters should be estimated most accurately to create detailed and reliable subject-specific MS models. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Nanoparticles for tendon healing and regeneration: literature review.

    Directory of Open Access Journals (Sweden)

    Paolo Domenico Parchi

    2016-08-01

    Full Text Available Tendon injuries are commonly met in the emergency department. Unfortunately, tendon tissue has limited regeneration potential and usually the consequent formation of scar tissue causes inferior mechanical properties Nanoparticles could be used in different way to improve tendon healing and regeneration, ranging from scaffolds manufacturing (increasing the strength and endurance or anti-adhesions, anti-microbial and anti-inflammatory properties to gene therapy. This paper aims to summarize the most relevant studies showing the potential application of nanoparticles for tendon tissue regeneration

  15. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    Science.gov (United States)

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria

  16. Pseudotear of the peroneus longus tendon on MRI, secondary to a fibrocartilaginous node

    Energy Technology Data Exchange (ETDEWEB)

    Didolkar, Manjiri M. [Harvard Medical School, Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Malone, Alfred L. [Radiology of Huntsville, PC, Huntsville, AL (United States); Nunley, James A. [Duke University Medical Center, Department of Orthopaedic Surgery, Durham, NC (United States); Dodd, Leslie G. [Duke University Medical Center, Department of Pathology, Durham, NC (United States); Helms, Clyde A. [Duke University Medical Center, Department of Radiology, Durham, NC (United States)

    2012-11-15

    The purpose of this study was to identify the presence of a fibrocartilaginous node within the distal peroneus longus tendon (PLT) just proximal to the cubital tunnel and correlate this with MRI signal characteristics of the distal PLT, which could result in a pseudotear appearance on MRI. We correlated imaging characteristics with pathologic specimens. Institutional review board approval was obtained. Retrospectively, 91 ankle MRIs utilizing a standard ankle protocol were reviewed by two musculoskeletal radiologists. Four cadaver ankles were imaged using a standard ankle MRI protocol and reviewed by the same radiologists. All the MRIs were examined for signal changes in the PLT. The cadaver ankles then underwent PLT dissection by an orthopaedic surgeon, and a pathologic review was undertaken by a pathologist with orthopaedic specialization, who looked for an os peroneum or proposed fibrocartilaginous node relating to the signal change found on the MRIs. In the 91 ankle MRI studies, the PLT demonstrated normal low and increased signals. On the fat-saturated T2-weighted sequence, 76 (83.5%) ankles demonstrated low signal and 15 (16.5%) demonstrated increased signal. Of the cadaver ankle MRIs, all four demonstrated increased signal within the PLT; three contained a fibrocartilaginous node and one contained an os peroneum in that same region. The MRI signal of the PLT can change with the presence of a fibrocartilaginous node, which may be due to the molecular and chemical content of the fibrocartilage. This node increases the MRI signal in the distal PLT and gives the appearance of a pseudotear. (orig.)

  17. Pseudotear of the peroneus longus tendon on MRI, secondary to a fibrocartilaginous node

    International Nuclear Information System (INIS)

    Didolkar, Manjiri M.; Malone, Alfred L.; Nunley, James A.; Dodd, Leslie G.; Helms, Clyde A.

    2012-01-01

    The purpose of this study was to identify the presence of a fibrocartilaginous node within the distal peroneus longus tendon (PLT) just proximal to the cubital tunnel and correlate this with MRI signal characteristics of the distal PLT, which could result in a pseudotear appearance on MRI. We correlated imaging characteristics with pathologic specimens. Institutional review board approval was obtained. Retrospectively, 91 ankle MRIs utilizing a standard ankle protocol were reviewed by two musculoskeletal radiologists. Four cadaver ankles were imaged using a standard ankle MRI protocol and reviewed by the same radiologists. All the MRIs were examined for signal changes in the PLT. The cadaver ankles then underwent PLT dissection by an orthopaedic surgeon, and a pathologic review was undertaken by a pathologist with orthopaedic specialization, who looked for an os peroneum or proposed fibrocartilaginous node relating to the signal change found on the MRIs. In the 91 ankle MRI studies, the PLT demonstrated normal low and increased signals. On the fat-saturated T2-weighted sequence, 76 (83.5%) ankles demonstrated low signal and 15 (16.5%) demonstrated increased signal. Of the cadaver ankle MRIs, all four demonstrated increased signal within the PLT; three contained a fibrocartilaginous node and one contained an os peroneum in that same region. The MRI signal of the PLT can change with the presence of a fibrocartilaginous node, which may be due to the molecular and chemical content of the fibrocartilage. This node increases the MRI signal in the distal PLT and gives the appearance of a pseudotear. (orig.)

  18. Reproducibility and clinical utility of tendon palpation to detect patellar tendinopathy in young basketball players. Victorian Institute of Sport tendon study group.

    Science.gov (United States)

    Cook, J L; Khan, K M; Kiss, Z S; Purdam, C R; Griffiths, L

    2001-02-01

    Palpation is an important clinical test for jumper's knee. To (a) test the reproducibility of palpation tenderness, (b) evaluate the sensitivity and specificity of palpation in subjects with clinical symptoms of jumper's knee, and (c) determine whether tenderness to palpation may serve as a useful screening test for patellar tendinopathy. The yardstick for diagnosis of patellar tendinopathy was ultrasonographic abnormality. In 326 junior symptomatic and asymptomatic athletes' tendons, palpation was performed by a single examiner before ultrasonographic examination by a certified ultrasound radiologist. In 58 tendons, palpation was performed twice to test reliability. Tenderness to palpation was scored on a scale from 0 to 3 where 0 represented no pain, and 1, 2, and 3 represented mild, moderate, and severe tenderness respectively. Patellar tendon palpation was a reliable examination for a single examiner (Pearson r = 0.82). In symptomatic tendons, the positive predictive value of palpation was 68%. As a screening examination in asymptomatic subjects, the positive predictive value of tendon palpation was 36-38%. Moderate and severe palpation tenderness were better predictors of ultrasonographic tendon pathology than absent or mild tenderness (ppatellar tendinopathy in a preparticipation examination. In symptomatic tendons, palpation is a moderately sensitive but not specific test. Mild tenderness in the patellar tendons in asymptomatic jumping athletes should be considered normal.

  19. Science to Practice: Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    Science.gov (United States)

    Lee, Kenneth S; Martin, Jack; Thelen, Darryl

    2017-05-01

    Compression-based ultrasonographic (US) elastography is associated with time-dependent mechanical and histologic changes of the healing tendon in a transected rabbit model of the Achilles tendon. This finding will lead to continued development of quantitative US, which can be used to objectively assess a diseased or healing tendon. With advances in the method used, clinical translation of tendon elastography may enable clinicians to diagnose tendon damage and track healing, which should improve both treatment and outcome.

  20. Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy

    NARCIS (Netherlands)

    Snedeker, J.G.; Foolen, J.

    2017-01-01

    Tendon is an intricately organized connective tissue that efficiently transfers muscle force to the bony skeleton. Its structure, function, and physiology reflect the extreme, repetitive mechanical stresses that tendon tissues bear. These mechanical demands also lie beneath high clinical rates of

  1. MRI and gross anatomy of the iliopsoas tendon complex

    International Nuclear Information System (INIS)

    Polster, Joshua M.; Lee, Ho; Klika, Alison; Barsoum, Wael; Drake, Richard; Elgabaly, Mohamed

    2008-01-01

    The objective was to explain the anatomic basis of a longitudinal cleft of increased signal in the iliopsoas tendon seen on hip MR arthrograms. A prospective review of 20 MR hip arthrograms was performed using standard and fat-suppressed T1-weighted images to establish whether or not the cleft was composed of fatty tissue and to define the anatomy of the iliopsoas tendon complex. Three cadaver dissections of the hip region were then performed for anatomic correlation. Fourteen out of 20 MR hip arthrograms demonstrated a longitudinal cleft of increased T1 signal adjacent to the iliopsoas tendon, which suppressed on frequency selective fat-suppressed images, indicating fatty composition. Gross anatomic correlation demonstrated this fatty cleft to represent a fascial plane adjacent to the iliopsoas tendon, in one case separating the iliopsoas tendon medially from a thin intramuscular tendon within the lateral portion of the iliacus muscle. Also noted was a direct muscular insertion of the lateral portion of the iliacus muscle onto the anterior portion of the proximal femoral diaphysis in all 3 cadavers. The anatomy of the iliopsoas tendon complex is more complicated than typically illustrated and includes the iliopsoas tendon itself attaching to the lesser trochanter, the lateral portion of the iliacus muscle attaching directly upon the anterior portion of the proximal femoral diaphysis, and a thin intramuscular tendon within this lateral iliacus muscle that is separated from the iliopsoas tendon by a cleft of fatty fascia that accounts for the MRI findings of a cleft of increased T1 signal. (orig.)

  2. Biceps brachii long head overactivity associated with elbow flexion contracture in brachial plexus birth palsy.

    Science.gov (United States)

    Sheffler, Lindsey C; Lattanza, Lisa; Sison-Williamson, Mitell; James, Michelle A

    2012-02-15

    The etiology of elbow flexion contracture in children with brachial plexus birth palsy remains unclear. We hypothesized that the long head of the biceps brachii muscle assists with shoulder stabilization in children with brachial plexus birth palsy and that overactivity of the long head during elbow and shoulder activity is associated with an elbow flexion contracture. Twenty-one patients with brachial plexus birth palsy-associated elbow flexion contracture underwent testing with surface electromyography. Twelve patients underwent repeat testing with fine-wire electromyography. Surface electrodes were placed on the muscle belly, and fine-wire electrodes were inserted bilaterally into the long and short heads of the biceps brachii. Patients were asked to perform four upper extremity tasks: elbow flexion-extension, hand to head, high reach, and overhead ball throw. The mean duration of muscle activity in the affected limb was compared with that in the contralateral, unaffected limb, which was used as a control. Three-dimensional motion analysis, surface dynamometry, and validated function measures were used to evaluate upper extremity kinematics, elbow flexor-extensor muscle imbalance, and function. The mean activity duration of the long head of the biceps brachii muscle was significantly higher in the affected limb as compared with the contralateral, unaffected limb during hand-to-head tasks (p = 0.02) and high-reach tasks (p = 0.03). No significant differences in mean activity duration were observed for the short head of the biceps brachii muscle between the affected and unaffected limbs. Isometric strength of elbow flexion was not significantly higher than that of elbow extension in the affected limb (p = 0.11). Overactivity of the long head of the biceps brachii muscle is associated with and may contribute to the development of elbow flexion contracture in children with brachial plexus birth palsy. Elbow flexion contracture may not be associated with an elbow

  3. Torque Control of Underactuated Tendon-driven Robotic Fingers

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Ihrke, Chris A. (Inventor); Reiland, Matthew J. (Inventor); Wampler, Charles W. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Bridgwater, Lyndon (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  4. Smart Tendon Actuated Flexible Actuator

    Directory of Open Access Journals (Sweden)

    Md. Masum Billah

    2015-01-01

    Full Text Available We investigate the kinematic feasibility of a tendon-based flexible parallel platform actuator. Much of the research on tendon-driven Stewart platforms is devoted either to the completely restrained positioning mechanism (CRPM or to one particular type of the incompletely restrained positioning mechanism (IRPM where the external force is provided by the gravitational pull on the platform such as in cable-suspended Stewart platforms. An IRPM-based platform is proposed which uses the external force provided by a compliant member. The compliant central column allows the configuration to achieve n DOFs with n tendons. In particular, this investigation focuses on the angular deflection of the upper platform with respect to the lower platform. The application here is aimed at developing a linkable module that can be connected to one another so as to form a “snake robot” of sorts. Since locomotion takes precedence over positioning in this application, a 3-DOF Stewart platform is adopted. For an arbitrary angular displace of the end-effector, the corresponding length of each tendon can be determined through inverse kinematics. Mathematical singularities are investigated using the traditional analytical method of defining the Jacobian.

  5. Changes in recruitment order of motor units in the human biceps muscle

    NARCIS (Netherlands)

    Haar Romenij, ter B.M.; Denier van der Gon, J.J.; Gielen, C.C.A.M.

    1982-01-01

    Changes in recruitment threshold of individual motor units of the human biceps (caput longum), a multifunctional muscle, were investigated during different tasks, i.e., isometric flexion of the elbow, isometric supination of the forearm, and isometric exorotation of the humerus of the 110° flexed

  6. Partial tear of the quadriceps tendon in a child

    International Nuclear Information System (INIS)

    Khanna, Geetika; El-Khoury, George

    2008-01-01

    We present a case of partial rupture of the quadriceps tendon in an 8-year-old girl. This is one of the youngest patients reported with a quadriceps tendon rupture, an entity seen predominantly in middle-aged people. The strength of the muscle tendon unit in a child makes tendon injuries extremely unusual as compared to apophyseal avulsions. The MR imaging findings of this unusual pediatric injury are illustrated. (orig.)

  7. Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    Science.gov (United States)

    Yamamoto, Yohei; Yamaguchi, Satoshi; Sasho, Takahisa; Fukawa, Taisuke; Akatsu, Yorikazu; Akagi, Ryuichiro; Yamaguchi, Tadashi; Takahashi, Kenji; Nagashima, Kengo; Takahashi, Kazuhisa

    2017-05-01

    Purpose To determine the time-dependent change in strain ratios (SRs) at the healing site of an Achilles tendon rupture in a rabbit model of tendon transection and to assess the correlation between SRs and the mechanical and histologic properties of the healing tissue. Materials and Methods Experimental methods were approved by the institutional animal care and use committee. The Achilles tendons of 24 New Zealand white rabbits (48 limbs) were surgically transected. The SRs of Achilles tendons were calculated by using compression-based quantitative ultrasonographic elastography measurements obtained 2, 4, 8, and 12 weeks after transection. After in vivo elastography, the left Achilles tendon was harvested for mechanical testing of ultimate load, ultimate stress, elastic modulus, and linear stiffness, and the right tendons were harvested for tissue histologic analysis with the Bonar scale. Time-dependent changes in SRs, mechanical parameters, and Bonar scale scores were evaluated by using repeated-measures analysis of variance. The correlation between SRs and each measured variable was evaluated by using the Spearman rank correlation coefficient. Results Mean SRs and Bonar scale values decreased as a function of time after transection, whereas mechanical parameters increased (P tendon. © RSNA, 2017 Online supplemental material is available for this article.

  8. Hyperuricemic PRP in Tendon Cells

    Directory of Open Access Journals (Sweden)

    I. Andia

    2014-01-01

    Full Text Available Platelet-rich plasma (PRP is injected within tendons to stimulate healing. Metabolic alterations such as the metabolic syndrome, diabetes, or hyperuricemia could hinder the therapeutic effect of PRP. We hypothesise that tendon cells sense high levels of uric acid and this could modify their response to PRP. Tendon cells were treated with allogeneic PRPs for 96 hours. Hyperuricemic PRP did not hinder the proliferative actions of PRP. The gene expression pattern of inflammatory molecules in response to PRP showed absence of IL-1b and COX1 and modest expression of IL6, IL8, COX2, and TGF-b1. IL8 and IL6 proteins were secreted by tendon cells treated with PRP. The synthesis of IL6 and IL8 proteins induced by PRP is decreased significantly in the presence of hyperuricemia (P = 0.017 and P = 0.012, resp.. Concerning extracellular matrix, PRP-treated tendon cells displayed high type-1 collagen, moderate type-3 collagen, decorin, and hyaluronan synthase-2 expression and modest expression of scleraxis. Hyperuricemia modified the expression pattern of extracellular matrix proteins, upregulating COL1 (P = 0.036 and COMP (P = 0.012 and downregulating HAS2 (P = 0.012. Positive correlations between TGF-b1 and type-1 collagen (R = 0.905, P = 0.002 and aggrecan (R = 0.833, P = 0.010 and negative correlations between TGF-b1 and IL6 synthesis (R = −0.857, P = 0.007 and COX2 (R = −0.810, P = 0.015 were found.

  9. Distal corporoplasty for distal cylinders extrusion after penile prosthesis implantation.

    Science.gov (United States)

    Carrino, Maurizio; Chiancone, Francesco; Battaglia, Gaetano; Pucci, Luigi; Fedelini, Paolo

    2017-02-03

    Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Several methods have been proposed for repairing a distal penile erosion. We present our preliminary experience in "Distal corporoplasty" technique. We enrolled 18 consecutive patients whose underwent a distal corporoplasty with simultaneous reimplantation of an "AMS 700 inflatable penile prosthesis (LGX)" from January 2013 to November 2015 at our hospital. All procedures were performed by a single surgical team. Intraoperative and postoperative complications have been classified and reported according to Satava6 and Clavien-Dindo (CD) system.7 Mean values with standard deviations (±SD) were computed and reported for all items. Mean age of the patients was 53.61 (±11.90) years. Mean body max index (BMI) was 24.22 (±2.51). Mean operative time was 85.2 (±13.1) minutes. Blood losses were minimal. No intraoperative complications are reported according to Satava classification. Four out of 18 patients (22.22%) experienced postoperative complications according to CD system. All patients had sexual intercourse for the first time postsurgery after a mean of 59.11 ± 2.08 days. Mean follow-up was 22.11 (±9.95). Distal extrusion of cylinders is a potential complication of the penile prosthesis implantation. Distal corporoplasty was first described by Mulcahy. He reported a series of 14 patients with a follow-up of about 2 years with optimal functional outcomes. Moreover, distal corporoplasty resulted in shorter operative time, better function, less pain, and fewer recurrences than Gortex windsock repair.10 In our experience, distal corporoplasty is a simple and safe procedure in the treatment of distal cylinders extrusion when the prosthetic material is not exposed to the exterior.

  10. Intersection syndrome: MR imaging with anatomic comparison of the distal forearm

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Jose E. de; Kim, Hyun-Jin; Albertotti, Flavio; Resnick, Donald [University of California, San Diego, VA San Diego Healthcare System, San Diego (United States)

    2004-11-01

    To correlate the anatomic and MR imaging characteristics of the area of intersection of the first and the second dorsal extensor tendon compartments (DETC) in the distal forearm in an attempt to improve the design of MR imaging protocols used for the evaluation of intersection syndrome. Ten forearms of nine cadavers underwent MR imaging in the axial and sagittal-oblique planes before and after tenography with direct injection of a gadolinium-containing contrast agent into the first DETC in four forearms, the second DETC in four forearms, and both compartments in the remaining two forearms. The area of intersection between the first and second DETC was identified in each case as well as its distance from Lister's tubercle. Subsequently all forearms were sectioned in the axial (8 forearms) or sagittal-oblique planes (2 remaining forearms) to parallel the imaging planes. Detailed examination of each of the anatomic slices was performed in a search for anatomic variations and for possible anatomic connections of the tendons sheaths. One forearm was dissected to identify the area of intersection. The area of intersection between the first and second DETC occurred between 3.5 cm and 4.8 cm (mean 4.18 cm) proximal to Lister's tubercle. After tenography, gadolinium solution was noted in the third DETC in two of four specimens in which the second DETC was injected and in one of two specimens in which both the first and second DETC were injected. Extension of the gadolinium solution between the first and second DETC was noted during isolated injections of either compartment, although this finding may have related to iatrogenic injection effects. The axial plane was the most valuable for assessment of the area of intersection of the first and second DETC. MR imaging is a noninvasive method that can be used for the evaluation of distal forearm and wrist pain. Standard wrist protocols do not include the area of intersection between the first and second DETC and, in

  11. Intersection syndrome: MR imaging with anatomic comparison of the distal forearm

    International Nuclear Information System (INIS)

    Lima, Jose E. de; Kim, Hyun-Jin; Albertotti, Flavio; Resnick, Donald

    2004-01-01

    To correlate the anatomic and MR imaging characteristics of the area of intersection of the first and the second dorsal extensor tendon compartments (DETC) in the distal forearm in an attempt to improve the design of MR imaging protocols used for the evaluation of intersection syndrome. Ten forearms of nine cadavers underwent MR imaging in the axial and sagittal-oblique planes before and after tenography with direct injection of a gadolinium-containing contrast agent into the first DETC in four forearms, the second DETC in four forearms, and both compartments in the remaining two forearms. The area of intersection between the first and second DETC was identified in each case as well as its distance from Lister's tubercle. Subsequently all forearms were sectioned in the axial (8 forearms) or sagittal-oblique planes (2 remaining forearms) to parallel the imaging planes. Detailed examination of each of the anatomic slices was performed in a search for anatomic variations and for possible anatomic connections of the tendons sheaths. One forearm was dissected to identify the area of intersection. The area of intersection between the first and second DETC occurred between 3.5 cm and 4.8 cm (mean 4.18 cm) proximal to Lister's tubercle. After tenography, gadolinium solution was noted in the third DETC in two of four specimens in which the second DETC was injected and in one of two specimens in which both the first and second DETC were injected. Extension of the gadolinium solution between the first and second DETC was noted during isolated injections of either compartment, although this finding may have related to iatrogenic injection effects. The axial plane was the most valuable for assessment of the area of intersection of the first and second DETC. MR imaging is a noninvasive method that can be used for the evaluation of distal forearm and wrist pain. Standard wrist protocols do not include the area of intersection between the first and second DETC and, in those cases

  12. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  13. Tendon shift in hallux valgus: observations at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Williamson, D. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Wilson, M. [Department of Orthopedics, Brigham and Womens Hospital, Boston, Massachusetts (United States); O`Byrne, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Bussolari, L. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Thomas, M. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Stephens, M. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Stack, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Weissman, B. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States)

    1996-08-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab.

  14. Tendon shift in hallux valgus: observations at MR imaging

    International Nuclear Information System (INIS)

    Eustace, S.; Williamson, D.; Wilson, M.; O'Byrne, J.; Bussolari, L.; Thomas, M.; Stephens, M.; Stack, J.; Weissman, B.

    1996-01-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab

  15. Tendon material properties vary and are interdependent among turkey hindlimb muscles.

    Science.gov (United States)

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P; Roberts, Thomas J

    2012-10-15

    The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress-strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r(2)=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity.

  16. Bifocal osseous avulsion of the patellar tendon from the distal patella and tibial tuberosity in a child

    DEFF Research Database (Denmark)

    Lykke Hermansen, Lars; Gade Freund, Knud

    2016-01-01

    This case report describes a 12-year-old boy, who suffered an injury to the right knee in a skateboard accident. Radiographs and surgery confirmed the extremely rare bifocal avulsion fracture including the distal patellar pole and tibial tuberosity. Open reduction and internal fixation was accomp...... was accomplished, and 4-month follow-up demonstrated a good outcome. © 2015, European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA)....

  17. Repeated freeze-thaw cycles reduce the survival rate of osteocytes in bone-tendon constructs without affecting the mechanical properties of tendons.

    Science.gov (United States)

    Suto, Kaori; Urabe, Ken; Naruse, Kouji; Uchida, Kentaro; Matsuura, Terumasa; Mikuni-Takagaki, Yuko; Suto, Mitsutoshi; Nemoto, Noriko; Kamiya, Kentaro; Itoman, Moritoshi

    2012-03-01

    Frozen bone-patellar tendon bone allografts are useful in anterior cruciate ligament reconstruction as the freezing procedure kills tissue cells, thereby reducing immunogenicity of the grafts. However, a small portion of cells in human femoral heads treated by standard bone-bank freezing procedures survive, thus limiting the effectiveness of allografts. Here, we characterized the survival rates and mechanisms of cells isolated from rat bones and tendons that were subjected to freeze-thaw treatments, and evaluated the influence of these treatments on the mechanical properties of tendons. After a single freeze-thaw cycle, most cells isolated from frozen bone appeared morphologically as osteocytes and expressed both osteoblast- and osteocyte-related genes. Transmission electron microscopic observation of frozen cells using freeze-substitution revealed that a small number of osteocytes maintained large nuclei with intact double membranes, indicating that these osteocytes in bone matrix were resistant to ice crystal formation. We found that tendon cells were completely killed by a single freeze-thaw cycle, whereas bone cells exhibited a relatively high survival rate, although survival was significantly reduced after three freeze-thaw cycles. In patella tendons, the ultimate stress, Young's modulus, and strain at failure showed no significant differences between untreated tendons and those subjected to five freeze-thaw cycles. In conclusion, we identified that cells surviving after freeze-thaw treatment of rat bones were predominantly osteocytes. We propose that repeated freeze-thaw cycles could be applied for processing bone-tendon constructs prior to grafting as the treatment did not affect the mechanical property of tendons and drastically reduced surviving osteocytes, thereby potentially decreasing allograft immunogenecity.

  18. A study of the distribution of color Doppler flows in the superficial digital flexor tendon of young Thoroughbreds during their training periods.

    Science.gov (United States)

    Hatazoe, Takashi; Endo, Yoshiro; Iwamoto, Yohei; Korosue, Kenji; Kuroda, Taisuke; Inoue, Saemi; Murata, Daiki; Hobo, Seiji; Misumi, Kazuhiro

    2015-01-01

    Aim of this study was to evaluate the relationships of exercise and tendon injury with Doppler flows appearing in the superficial digital flexor tendon (SDFT) of young Thoroughbreds during training periods. The forelimb SDFTs of 24 one- to two-year-old Thoroughbreds clinically free of any orthopaedic disorders were evaluated using grey-scale (GS) and color Doppler (CD) images during two training periods between December 2013 to April 2015. Twelve horses per year were examined in December, February, and April in training periods that began in September and ended in April. The SDFT was evaluated in 3 longitudinal images of equal lengths (labelled 1, 2, 3 in order from proximal to distal), and 6 transversal images separated by equal lengths (labelled 1A, 1B, 2A, 2B, 3A and 3B in order from proximal to distal) of the metacarpus using both GS and CD. The running (canter and gallop) distance for 1 month before the date of the ultrasonographic examinations was increased in December, February, and April in both of the two training periods. CD flows defined as rhythmically blinking or pulsatory colored signals were found in 56 of 864 (6.4%) transversal CD images, in 28, 12, 13, and 3 images of 1A, 1B, 2A and 2B, respectively, and in 7, 14, and 35 images captured in December, February, and April, respectively. There were no longitudinal or transversal GS images indicating injury in the SDFTs in either of the two training periods. The increase of CD flows in the proximal regions of the SDFT are possibly related to the increase of the running distance during the training periods of the one- to two-year-old Thoroughbreds. Because no injury was diagnosed in the SDFTs by GS images during the training periods, the increase of CD flows in the proximal parts of SDFT is not necessarily predictive of tendon injury in the near future during the training period of young Thoroughbreds.

  19. Loss of reduction and complications of coracoclavicular ligament reconstruction with autogenous tendon graft in acute acromioclavicular dislocations.

    Science.gov (United States)

    Choi, Nam Hong; Lim, Seok Min; Lee, Sang Young; Lim, Tae Kang

    2017-04-01

    This study was conducted to report loss of reduction and complications after single-tunnel coracoclavicular (CC) ligament reconstruction with autogenous semitendinosus tendon graft for acute acromioclavicular (AC) joint dislocations. This retrospective study included patients with acute, unstable AC dislocations (surgery within 6 weeks after trauma). We excluded patients with chronic injury and distal clavicle fractures with CC ligaments disruption. We measured the CC distance on anteroposterior radiographs of both clavicles, preoperatively, immediately postoperatively, and at the final follow-up visit. We evaluated clinical outcomes using the American Shoulder and Elbow Surgeons Shoulder Assessment and the University of California, Los Angeles Shoulder Rating Scale scores and perioperative complications. There were 30 patients (27 men and 3 women) with mean age of 41 years (range, 19-70 years). The mean follow-up period was 31 months (range, 12-186 months). Mean CC distance was 15.5 ± 3.7 mm (84% ± 14% of the contralateral shoulder) preoperatively, 8.9 ± 2.6 mm (9% ± 40%) immediately postoperatively (P 25% increase of CC distance) developed in 14 patients (47%), and complications occurred in 6 patients (20%), including 3 distal clavicle fractures through the tunnel. Final clinical scores were significantly lower in patients with complications (27 vs. 33 of the University of California, Los Angeles assessment [P < .001] and 81 vs. 95 of the American Shoulder and Elbow Surgeons Shoulder assessment [P < .001]). In acute AC joint dislocation, single-tunnel CC ligament reconstruction using autogenous tendon graft resulted in loss of reduction rate of 47% and a complication rate of 20%. The development of complications adversely affected clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Calcaneal tendon: imaging findings; Tendao calcaneo: avaliacao por imagem

    Energy Technology Data Exchange (ETDEWEB)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio [Colegio Brasileiro de Radiologia e Diagnostico por Imagem, Sao Paulo, SP (Brazil)]. E-mail: crismontandon@hotmail.com; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos [Goias Univ., Goiania, GO (Brazil). Hospital de Clinicas. Dept. de Diagnostico por Imagem e Anatomia Patologica

    2003-12-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  1. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    Science.gov (United States)

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  2. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    International Nuclear Information System (INIS)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-01-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders

  3. Achilles tendon: US diagnosis of pathologic conditions. Work in progress

    Energy Technology Data Exchange (ETDEWEB)

    Blei, C.L.; Nirschl, R.P.; Grant, E.G.

    1986-06-01

    Twenty-three patients were prospectively examined with ultra-sound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditions and to contribute to the diagnosis of a broad range of Achilles tendon disorders.

  4. Tendon synovial cells secrete fibronectin in vivo and in vitro

    International Nuclear Information System (INIS)

    Banes, A.J.; Link, G.W.; Bevin, A.G.; Peterson, H.D.; Gillespie, Y.; Bynum, D.; Watts, S.; Dahners, L.

    1988-01-01

    The chemistry and cell biology of the tendon have been largely overlooked due to the emphasis on collagen, the principle structural component of the tendon. The tendon must not only transmit the force of muscle contraction to bone to effect movement, but it must also glide simultaneously over extratendonous tissues. Fibronectin is classified as a cell attachment molecule that induces cell spreading and adhesion to substratum. The external surface of intact avian flexor tendon stained positively with antibody to cellular fibronectin. However, if the surface synovial cells were first removed with collagenase, no positive reaction with antifibronectin antibody was detected. Analysis of immunologically stained frozen sections of tendon also revealed fibronectin at the tendon synovium, but little was associated with cells internal in tendon. The staining pattern with isolated, cultured synovial cells and fibroblasts from the tendon interior substantiated the histological observations. Analysis of polyacrylamide gel profiles of 35 S-methionine-labeled proteins synthesized by synovial cells and internal fibroblasts indicated that fibronectin was synthesized principally by synovial cells. Fibronectin at the tendon surface may play a role in cell attachment to prevent cell removal by the friction of gliding. Alternatively, fibronectin, with its binding sites for hyaluronic acid and collagen, may act as a complex for boundary lubrication

  5. Variable effect of steam injection level on beef muscles: semitendinosus and biceps femoris cooked in convection-steam oven.

    Science.gov (United States)

    Zając, Marzena; Kącik, Sławomir; Palka, Krystyna; Widurek, Paweł

    2015-01-01

    Combi ovens are used very often in restaurants to heat up food. According to the producers the equipment allows to cook meat portions which are more tender and flavoursome comparing to conventional cooking techniques. Beef steaks from muscles semitendinosus and biceps femoris were cooked in convection-steam oven at three humidity levels: 10, 60 and 100%. Chemical composition, including total and insoluble collagen content and cook losses were analysed along with the texture and colour parameters. M. biceps femoris was the hardest and the most chewy at 100% steam saturation level and hardness measured for m. semitendinosus was the lowest at 10% of vapour injection. Changing the steam conditions in the oven chamber did not affect the detectable colour differences of m. biceps femoris, but it was significant for m. semitendinosus. Applying 100% steam saturation caused higher cook losses and the increase of insoluble collagen fractions in both analysed muscles. The results are beneficial for caterers using steam-convection ovens in terms of providing evidence that the heating conditions should be applied individually depending on the muscle used. The tenderness of m. semitendinosus muscle cooked at 10% steam saturation level was comparable to the tenderness obtained for the same muscle aged for 10 days and cooked with 100% steam saturation. Steaks from m. biceps femoris muscle should be cooked with maximum 60% saturation level to obtain higher tenderness.

  6. Sex Variation in Patellar Tendon Kinetics During Running

    Directory of Open Access Journals (Sweden)

    Sinclair Jonathan

    2015-06-01

    Full Text Available Purpose. The aim of the current investigation was to determine whether female recreational runners exhibit distinct patellar tendon loading patterns in relation to their male counterparts. Methods. Twelve male (age 26.55 ± 4.11 years, height 1.78 ± 0.11 m, mass 77.11 ± 5.06 kg and twelve female (age 26.67 ± 5.34 years, height 1.67 ± 0.12 m, mass 63.28 ± 9.75 kg runners ran over a force platform at 4.0 m · s-1. Lower limb kinematics were collected using an eight-camera optoelectric motion capture system which operated at 250 Hz. Patellar tendon loads were examined using a predictive algorithm. Sex differences in limb, knee and ankle joint stiffness were examined statistically using independent samples t tests. Results. The results indicate that patellar tendon force (male = 6.49 ± 2.28, female = 7.03 ± 1.35 and patelllar tendon loading rate (male = 92.41 ± 32.51, female = 111.05 ± 48.58 were significantly higher in female runners. Conclusions. Excessive tendon loading in female runners indicates that female runners may be at increased risk of patellar tendon pathologies.

  7. Effect of laceration and trimming of a tendon on the coefficient of friction along the A2 pulley: an in vitro study on turkey tendon.

    Science.gov (United States)

    Hajipour, L; Gulihar, A; Dias, J

    2010-08-01

    We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons in vitro and measured the coefficient of friction at the tendon-pulley interface with loads of 200 g and 400 g and in 10 degrees , 30 degrees, 50 degrees and 70 degrees of flexion. Laceration increased the coefficient of friction from 0.12 for the intact tendon to 0.3 at both the test loads. Trimming the laceration reduced the coefficient of friction to 0.2. An exponential increase in the gliding resistance was found at 50 degrees and 70 degrees of flexion (p = 0.02 and p = 0.003, respectively) following trimming compared to that of the intact tendon. We concluded that trimming partially lacerated flexor tendons will reduce the gliding resistance at the tendon-pulley interface, but will lead to fragmentation and triggering of the tendon at higher degrees of flexion and loading. We recommend that higher degrees of flexion be avoided during early post-operative rehabilitation following trimming of a flexor tendon.

  8. Content Analysis Schedule for Bilingual Education Programs: BICEP Intercambio de la Cultura.

    Science.gov (United States)

    Shore, Marietta Saravia; Nafus, Charles

    This content analysis schedule for BICEP Intercambio de la Cultura (San Bernardino, California), presents information on the history, funding, and scope of the project. Included are sociolinguistic process variables such as the native and dominant languages of students and their interaction. Information is provided on staff selection and the…

  9. Adaptive Remodeling of Achilles Tendon: A Multi-scale Computational Model.

    Directory of Open Access Journals (Sweden)

    Stuart R Young

    2016-09-01

    Full Text Available While it is known that musculotendon units adapt to their load environments, there is only a limited understanding of tendon adaptation in vivo. Here we develop a computational model of tendon remodeling based on the premise that mechanical damage and tenocyte-mediated tendon damage and repair processes modify the distribution of its collagen fiber lengths. We explain how these processes enable the tendon to geometrically adapt to its load conditions. Based on known biological processes, mechanical and strain-dependent proteolytic fiber damage are incorporated into our tendon model. Using a stochastic model of fiber repair, it is assumed that mechanically damaged fibers are repaired longer, whereas proteolytically damaged fibers are repaired shorter, relative to their pre-damage length. To study adaptation of tendon properties to applied load, our model musculotendon unit is a simplified three-component Hill-type model of the human Achilles-soleus unit. Our model results demonstrate that the geometric equilibrium state of the Achilles tendon can coincide with minimization of the total metabolic cost of muscle activation. The proposed tendon model independently predicts rates of collagen fiber turnover that are in general agreement with in vivo experimental measurements. While the computational model here only represents a first step in a new approach to understanding the complex process of tendon remodeling in vivo, given these findings, it appears likely that the proposed framework may itself provide a useful theoretical foundation for developing valuable qualitative and quantitative insights into tendon physiology and pathology.

  10. Distal digital replantation.

    Science.gov (United States)

    Jazayeri, Leila; Klausner, Jill Q; Chang, James

    2013-11-01

    Hand surgeons have been hesitant to perform distal digital replantation because of the technical challenges and the perception of a high cost-to-benefit ratio. Recent studies, however, have shown high survival rates and excellent functional and aesthetic results, providing renewed enthusiasm for distal replantation. The authors reviewed the literature and summarize key points regarding the surgical treatment, perioperative care, and outcomes of distal digital replantation. They describe specific techniques and considerations for surgical repair in each of four distal zones as described by Sebastin and Chung. Zone 1A replantation involves an artery-only anastomosis of a longitudinal pulp artery. Venous anastomosis first becomes possible in zone 1B. Zone 1C involves periarticular amputations where arthrodesis of the distal interphalangeal joint is usually indicated. Repair of the artery, vein, and nerve is technically optimal in zone 1D, where venous anastomosis should be performed. Overall, survival rates for distal digital replantation are similar to those reported for more proximal replantation. The literature reports good outcomes regarding nail salvage, fingertip sensibility, and range of motion, with restoration of length and aesthetic appearance. Distal replantation performed at institutions that specialize in microsurgery and specifically tailored to the level of injury is associated with good survival, function, and patient satisfaction and superior aesthetic outcome. More prospective data are needed to evaluate the cost of treatment, psychological outcomes, and functional outcomes of distal replantation compared with revision amputation.

  11. The Relation between Calcium Supplement Consumption and Calcific Shoulder Tendonitis

    Directory of Open Access Journals (Sweden)

    Alireza Rouhani

    2015-10-01

    Full Text Available Background: Calcific tendonitis is a common cause of non-traumatic shoulder pain. Previous studies have suggested a relation between minerals and endocrine and calcium deposition. Thus, hypercalcemia is probably related to calcific tendonitis. This study aims at evaluating the relation found between calcium supplement consumption and calcific shoulder tendonitis. Methods: This analytical-descriptive study was conducted on 250 patients with shoulder pain referring to clinics and emergency department of Shohada Orthopedics Hospital during one year for considering calcific shoulder tendonitis and calcium supplement consumption. Patients with calcific tendonitis were treated and their functional ability was evaluated using DASH questionnaire, pain severity and range of motion (ROM before and after treatment and their correlation with calcium supplement consumption. Results: Calcific tendonitis and calcium consumption were generally seen in 30 (12% and 73 (29.2% cases, respectively. Calcium consumption frequency in patients with calcific tendonitis was significantly higher than the patients who did not consume calcium supplements (76.7% vs. 22.7%. Patients with calcific tendonitis who did not consume calcium supplements suffered from significantly longer periods of shoulder pain. All patients having consumed calcium supplement were female. The group who consumed calcium supplement had significantly severe pain and higher DASH score before and after treatment, while there was no significant difference in number of impaired ROM before and after treatment. Also, there was a negative correlation between calcium supplement consumption, pain severity and DASH score before and after treatment. Conclusion: Calcium supplement consumption is related to calcific tendonitis and is also accompanied with more pain and lower functional ability in patients with calcific tendonitis.    Keywords: Calcific tendonitis; Shoulder; Calcium supplement; Pain

  12. Micromechanical properties and collagen composition of ruptured human achilles tendon

    DEFF Research Database (Denmark)

    Hansen, Philip; Kovanen, Vuokko; Hölmich, Per

    2013-01-01

    The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.......The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive....

  13. Ultrasound diagnostics of muscle and tendon injuries

    Directory of Open Access Journals (Sweden)

    Stević Ruža

    2009-01-01

    Full Text Available Introduction. Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow-up of healing process. Objective. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. Methods. The study included 170 patients (148 male and 22 female, mean age 29.6 years (range 14-60 years. All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Results. Traumatic lesions of muscles were diagnosed in 113 patients (66.7% and tendon injuries in 57 cases (33.2%. The muscle changes detected by ultrasonography were the following: 70 (61.9% partial and two (1.76% complete ruptures, 22 (19.46% haematoma, 9 (7.96% strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively. Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8% ruptures and 36 (66.1% tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Conclusion. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  14. Quantitative Assessment of Tendon Healing by Using MR T2 Mapping in a Rabbit Achilles Tendon Transection Model Treated with Platelet-rich Plasma.

    Science.gov (United States)

    Fukawa, Taisuke; Yamaguchi, Satoshi; Watanabe, Atsuya; Sasho, Takahisa; Akagi, Ryuichiro; Muramatsu, Yuta; Akatsu, Yorikazu; Katsuragi, Joe; Endo, Jun; Osone, Fumio; Sato, Yasunori; Okubo, Toshiyuki; Takahashi, Kazuhisa

    2015-09-01

    To determine if magnetic resonance (MR) imaging T2 mapping can be used to quantify histologic tendon healing by using a rabbit Achilles tendon transection model treated with platelet-rich plasma (PRP). Experiments were approved by the Institutional Animal Care and Use Committee. The Achilles tendons of 24 New Zealand white rabbits (48 limbs) were surgically transected, and PRP (in the test group) or saline (in the control group) was injected into the transection site. The rabbits were sacrificed 2, 4, 8, and 12 weeks after surgery. Thereafter, T2 mapping and histologic evaluations were performed by using the Bonar scale. A mixed-model multivariate analysis of variance was used to test the effects of time and PRP treatment on the T2 value and Bonar grade, respectively. The correlation between the T2 value and Bonar grade was also assessed by using the Spearman correlation coefficient. The Bonar scale values decreased in both groups during tendon healing. The T2 value also shortened over time (P tendon healing. While T2 and Bonar grade were lower at all time points in tendons treated with PRP, there was no significant difference between the treatment and control tendons.

  15. Smad3 binds Scleraxis and Mohawk and regulates tendon matrix organization.

    Science.gov (United States)

    Berthet, Ellora; Chen, Carol; Butcher, Kristin; Schneider, Richard A; Alliston, Tamara; Amirtharajah, Mohana

    2013-09-01

    TGFβ plays a critical role in tendon formation and healing. While its downstream effector Smad3 has been implicated in the healing process, little is known about the role of Smad3 in normal tendon development or tenocyte gene expression. Using mice deficient in Smad3 (Smad3(-/-) ), we show that Smad3 ablation disrupts tendon architecture and has a dramatic impact on normal gene and protein expression during development as well as in mature tendon. In developing and adult tendon, loss of Smad3 results in reduced protein expression of the matrix components Collagen 1 and Tenascin-C. Additionally, when compared to wild type, tendon from adult Smad3(-/-) mice shows a down regulation of key tendon marker genes. Finally, we have established that Smad3 has the ability to physically interact with the critical transcriptional regulators Scleraxis and Mohawk. Together these results indicate a central role for Smad3 in normal tendon formation and in the maintenance of mature tendon. Copyright © 2013 Orthopaedic Research Society.

  16. Testing hybrid natural inflation with BICEP2

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo-González, Mariana [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251 Cuernavaca, Morelos (Mexico); Germán, Gabriel, E-mail: gabriel@fis.unam.mx [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251 Cuernavaca, Morelos (Mexico); Herrera-Aguilar, Alfredo [Departamento de Física, Universidad Autónoma Metropolitana Iztapalapa, San Rafael Atlixco 186, CP 09340, México D.F. (Mexico); Instituto de Física y Matemáticas, Universidad Michoacana de San Nicolás de Hidalgo, Edificio C-3, Ciudad Universitaria, CP 58040, Morelia, Michoacán (Mexico); Hidalgo, Juan Carlos [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251 Cuernavaca, Morelos (Mexico); Sussman, Roberto A. [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Apdo. Postal 70-543, 04510 México D.F. (Mexico)

    2014-06-27

    We analyse Hybrid Natural Inflation in view of the recent results for the tensor index reported by BICEP2. We find that it predicts a large running of the scalar spectrum which is potentially detectable by large scale structure through measurements of clustering of galaxies in combination with CMB data and by 21 cm forest observations. The running of the running is also relatively large becoming close to 10{sup −2}. Along the way, we find general consistency relations at which observables are subject if the slow-roll approximation is imposed. Failure to satisfy these equations by the values obtained for the observables in surveys would be a failure of the slow-roll approximation itself.

  17. Ultrasound-based testing of tendon mechanical properties

    DEFF Research Database (Denmark)

    Seynnes, O R; Bojsen-Møller, J.; Albracht, K

    2015-01-01

    In the past 20 years, the use of ultrasound-based methods has become a standard approach to measure tendon mechanical properties in vivo. Yet the multitude of methodological approaches adopted by various research groups probably contribute to the large variability of reported values. The technique......, or signal synchronization; and 2) in physiological considerations related to the viscoelastic behavior or length measurements of tendons. Hence, the purpose of the present review is to assess and discuss the physiological and technical aspects connected to in vivo testing of tendon mechanical properties...

  18. Nonsingular bouncing cosmologies in light of BICEP2

    International Nuclear Information System (INIS)

    Cai, Yi-Fu; Quintin, Jerome; Saridakis, Emmanuel N.; Wilson-Ewing, Edward

    2014-01-01

    We confront various nonsingular bouncing cosmologies with the recently released BICEP2 data and investigate the observational constraints on their parameter space. In particular, within the context of the effective field approach, we analyze the constraints on the matter bounce curvaton scenario with a light scalar field, and the new matter bounce cosmology model in which the universe successively experiences a period of matter contraction and an ekpyrotic phase. Additionally, we consider three nonsingular bouncing cosmologies obtained in the framework of modified gravity theories, namely the Hořava-Lifshitz bounce model, the f(T) bounce model, and loop quantum cosmology

  19. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  20. Effect of aging and exercise on the tendon

    DEFF Research Database (Denmark)

    Svensson, Rene B; Heinemeier, Katja Maria; Couppé, Christian

    2016-01-01

    Here, we review the literature on how tendons respond and adapt to ageing and exercise. With respect to aging, there are considerable changes early in life, but this seems to be maturation rather than aging per se. In vitro data indicate that aging is associated with a decreased potential for cel...... and modulus of the tendon and may reduce the amount of glycation. Exercise thereby tends to counteract the effects of aging.......Here, we review the literature on how tendons respond and adapt to ageing and exercise. With respect to aging, there are considerable changes early in life, but this seems to be maturation rather than aging per se. In vitro data indicate that aging is associated with a decreased potential for cell...... glycation-derived cross-links increase substantially. Mechanically, aging appears to be associated with a reduction in modulus and strength. With respect to exercise, tendon cells respond by producing growth factors, and there is some support for a loading-induced increase in tendon collagen synthesis...

  1. [Achilles tendon ruptures: 25 year's experience in sport-orthopedic treatment].

    Science.gov (United States)

    Majewski, M; Widmer, K H; Steinbrück, K

    2002-12-01

    From 1972 - 1996 570 Achilles tendon ruptures in 565 patients were treated in the Sportklinik Stuttgart. The 499 men and 66 women had an average age of 38 years. For the diagnosis of a Achilles tendon rupture Ultrasound and MRI are important procedures, but clinical history and examination are still the best methods to find an Achilles tendon rupture (100%). However,the Actiology of the Achilles tendon rupture is still controversial and cannot be answered by these methods. Opposed to the degenerative theory, biomechanical experiments show that any Achilles tendon can tear when the calf muscle is tensed before the tendon is quickly stretched. We found that 69.8% of the patients with Achilles tendon rupture had a real trauma. Regardless of that, the treatment of the ruptured Achilles tendon has considerably changed over the last ten years. Responsible for this development are the positive experiences at the field of sports medicine with minimally invasive methods and the early functional treatment after knee surgery. Since we use an early functional rehabilitation concept instead of plaster immobilisation, all methods to treat a ruptured Achilles tendon have been improved. 43.5% of the patients after plaster immobilisation and 28.8% of the patients after early functional rehabilitation had a subjectively felt force reduction. Other important selecting criteria are the risk factors related to treatment method. Minimal invasive percutaneous Achilles tendon repair is considerably better than conservative therapy with a high rate of re-rupture (9.8%) and better than the open surgical repair, which carries a higher risk of infection (2.2%)

  2. Contrast material filling of the peroneal tendon sheath

    International Nuclear Information System (INIS)

    Zadravecz, Gy.; Grexa, E.

    1981-01-01

    In case of complaints after fracture of the calcaneus the common sheath of the peroneus tendons was filled up with contrast material. The tendon sheath was punctured Oehind the external ankle. The three-directional radiograms clearly showed the dislocation and compression of the tendons, caused by the exostosis of the calcaneus. The concomitant tendovaginitis caused the complaints. This alteration was observed in 11% of all the calcaneus fractures. (L.E.)

  3. ANATOMIC AND PHYSIOLOGICAL FEATURES OF DISTAL LOWER LEG AND THEIR INFLUENCE ON THE PROCESS OF OSTEOGENESIS

    Directory of Open Access Journals (Sweden)

    Desimir Mladenović

    2010-06-01

    Full Text Available Osteogenesis is the process of bone tissue forming, i.e. bone or callus regeneration. This process is influenced by many factors, and the degree of bone fragments’ stability and vascularization in the fracture area are the basic local factors which determine the nature of reparative process. Regenerative process of all bone structures increases with increasing of blood supply.The distal lower leg has its specific biomechanical features, and plays an important role in the transfer of body weight to foot. The distal part of tibia has a small diameter, which as a consequence has reduced diameter in medullar cave. Through this anatomic feature, the medullar network in the lower tibia part is also reduced.As for anatomic aspect, vascularization in the lower end of tibia is poor. It primarily depends on periosteal vascularization, because medullar vascularization is reduced. Fasciae, tendons and skin cover the lower part of the leg, and there is no muscle mass. These tissues have poor vascular network and that is why the extraosseous blood circulation in tibia is poor, and does not participate in the osteogenesis process. For these reasons, distal lower leg represents a predelection site for delayed osteogenesis and pseudoarthrosys development.Osteosynthesis causes secondary damage to bone and soft tissue circulation. The screw plate damages the periosteal circulation – in the lower part of tibia it is the main source of vascularization, and for this reason, this method of osteosynthesis should not be applied. The external fixator has a sparing role regarding vascularization, and that is the reason why this method is recommended for fracture stabilization at the level of distal lower leg.

  4. Reproducibility of Ultrasound and Magnetic Resonance Imaging Measurements of Tendon Size

    International Nuclear Information System (INIS)

    Brushoej, C.; Henriksen, B.M.; Albrecht-Beste, E.; Hoelmich, P.; Larsen, K.; Bachmann Nielsen, M.

    2006-01-01

    Purpose: To investigate the intra- and inter-tester reproducibility of measurements of the Achilles tendon, tibialis anterior tendon, and the tibialis posterior tendon in football players using ultrasound (US) and magnetic resonance imaging (MRI). Material and Methods: Eleven asymptomatic football players were examined. Using a standardized US scanning protocol, the tendons were examined by two observers with US for thickness, width, and cross-sectional area. One observer conducted the procedure twice. The subjects also underwent an MRI examination, and the assessment of tendon size was conducted twice by two observers. Results: The best reproducibility judged by coefficient of variation (CV) and 95% confidence interval was determined for the Achilles tendon on both US and MRI. The variability of US on measurements on the tibialis anterior and tibialis posterior tendons was less than that when using MRI. In 12 out of 18 measurements, there were systematic differences between observers as judged by one-sided F-test. Conclusion: The reproducibility of the three tendons was limited. Precaution should be taken when looking for minor quantitative changes, i.e., training-induced hypertrophy, and when doing so, the Achilles tendon should be used

  5. Identification of Novel Equine (Equus caballus Tendon Markers Using RNA Sequencing

    Directory of Open Access Journals (Sweden)

    Jan M. Kuemmerle

    2016-11-01

    Full Text Available Although several tendon-selective genes exist, they are also expressed in other musculoskeletal tissues. As cell and tissue engineering is reliant on specific molecular markers to discriminate between cell types, tendon-specific genes need to be identified. In order to accomplish this, we have used RNA sequencing (RNA-seq to compare gene expression between tendon, bone, cartilage and ligament from horses. We identified several tendon-selective gene markers, and established eyes absent homolog 2 (EYA2 and a G-protein regulated inducer of neurite outgrowth 3 (GPRIN3 as specific tendon markers using RT-qPCR. Equine tendon cells cultured as three-dimensional spheroids expressed significantly greater levels of EYA2 than GPRIN3, and stained positively for EYA2 using immunohistochemistry. EYA2 was also found in fibroblast-like cells within the tendon tissue matrix and in cells localized to the vascular endothelium. In summary, we have identified EYA2 and GPRIN3 as specific molecular markers of equine tendon as compared to bone, cartilage and ligament, and provide evidence for the use of EYA2 as an additional marker for tendon cells in vitro.

  6. Influence of repetitive mechanical loading on MMP2 activity in tendon fibroblasts.

    Science.gov (United States)

    Huisman, Elise; Lu, Alex; Jamil, Sarwat; Mousavizadeh, Rouhollah; McCormack, Robert; Roberts, Clive; Scott, Alex

    2016-11-01

    Matrix metalloproteinase2 has been implicated in tendon pathology caused by repetitive movements. However, its activity in the early stages of the tendon's response to overuse, and its presence in the circulation as a possible indicator of tendon degradation, remain unknown. Human tendon cells were repetitively stretched for 5 days, and the rabbit Achilles tendon complex underwent repetitive motion 3× per week for 2 weeks. Quantitative polymer chain reaction analysis was performed to detect matrix metalloproteinase2/14 and tissue inhibitor of matrix metalloproteinase2 messenger ribonucleic acid of cells and rabbit tissue, and matrix metalloproteinase2 protein levels were determined with an enzyme linked immunoassay. Matrix metalloproteinase2 activity was examined using zymography of the conditioned media, tendon and serum. Immunohistochemistry was used to localize matrix metalloproteinase2 in tendon tissue, and the density of fibrillar collagen in tendons was examined using second harmonic generation microscopy. Tendon cells stretched with high strain or high frequency demonstrated increased matrix metalloproteinase2 messenger ribonucleic acid and protein levels. Matrix metalloproteinase2 activity was increased in the rabbit Achilles tendon tissue at weeks 1 and 2; however, serum activity was only increased at week 1. After 2 weeks of exercise, the collagen density was lower in specific regions of the exercised rabbit Achilles tendon complex. Matrix metalloproteinase2 expression in exercised rabbit Achilles tendons was detected surrounding tendon fibroblasts. Repetitive mechanical stimulation of tendon cells results in a small increase in matrix metalloproteinase2 levels, but it appears unlikely that serum matrix metalloproteinase2 will be a useful indicator of tendon overuse injury. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1991-2000, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. The relationship between shear force, compression, collagen characteristics, desmin degradation and sarcomere length in lamb biceps femoris.

    Science.gov (United States)

    Starkey, Colin P; Geesink, Geert H; van de Ven, Remy; Hopkins, David L

    2017-04-01

    This study aimed to identity the relationships between known variants of tenderness (collagen content (total and soluble), desmin degradation and sarcomere length) and shear force and compression in the biceps femoris aged for 14days from 112 mixed sex lambs. Desmin degradation was related to compression (Pcompression decreased. Sarcomere length (SL) was related to shear force (Pcompression (Pcompression, sarcomere length and soluble collagen. The findings from this experiment indicate that the known variants (soluble collagen, sarcomere length and desmin degradation) are related to shear force and compression in ovine biceps femoris. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  8. Maxillary molar distalization with the dual-force distalizer supported by mini-implants: a clinical study.

    Science.gov (United States)

    Oberti, Giovanni; Villegas, Carlos; Ealo, Martha; Palacio, John Camilo; Baccetti, Tiziano

    2009-03-01

    The objective of this prospective study was to describe the clinical effects of a bone-supported molar distalizing appliance, the dual-force distalizer. The study group included 16 patients (mean age, 14.3 years) with Class II molar relationships. Study models and lateral cephalograms were taken before and after the distalizing movement to record significant dental and skeletal changes (Wilcoxon test). The average distalization time was 5 months, with a movement rate of 1.2 mm per month; the distalization amounts were 5.9 +/- 1.72 mm at the crown level and 4.4 +/- 1.41 mm at the furcation level. The average molar inclination was 5.6 degrees +/- 3.7 degrees ; this was less than the amount of inclination generated by bone-supported appliances that use single distalizing forces. The correlation between inclination and distalization was not significant, indicating predominantly bodily movement. The teeth anterior to the first molar moved distally also; the second premolars distalized an average of 4.26 mm, and the incisors retruded by 0.53 mm. The dual-force distalizer is a valid alternative distalizing appliance that generates controlled molar distalization with a good rate of movement and no loss of anchorage.

  9. SUSY see-saw and NMSO(10)GUT inflation after BICEP2

    International Nuclear Information System (INIS)

    Garg, Ila

    2016-01-01

    Supersymmetric see-saw slow roll inflection point inflation occurs along a MSSM D-flat direction associated with gauge invariant combination of Higgs, s lepton and right-handed s neutrino at a scale set by the right-handed neutrino mass M vc ∼ 10 6 -10 13 GeV. The tensor to scalar perturbation ratio r ∼ 10 -3 can be achieved in this scenario. However, this scenario faced difficulty in being embedded in the realistic new minimal supersymmetric SO(10) grand unified theory (NMSO(10)GUT). The recent discovery of B-mode polarization by BICEP2, changes the prospects of NMSO(10) GUT inflation. Inflection point models become strongly disfavoured, as the trilinear coupling of SUSY see-saw inflation potential gets suppressed relative to the mass parameter favoured by BICEP2. Large values of r ≈ 0.2 can be achieved with super-Planck scale inflaton values and mass scales of inflaton ≥10 13 GeV. In NMSO(10)GUT, this can be made possible with an admixture of heavy Higgs doublet fields, i.e., other than MSSM Higgs field, which are present and have masses of order GUT scale. (author)

  10. Different Achilles Tendon Pathologies Show Distinct Histological and Molecular Characteristics

    Directory of Open Access Journals (Sweden)

    Franka Klatte-Schulz

    2018-01-01

    Full Text Available Reasons for the development of chronic tendon pathologies are still under debate and more basic knowledge is needed about the different diseases. The aim of the present study was therefore to characterize different acute and chronic Achilles tendon disorders. Achilles tendon samples from patients with chronic tendinopathy (n = 7, chronic ruptures (n = 6, acute ruptures (n = 13, and intact tendons (n = 4 were analyzed. The histological score investigating pathological changes was significantly increased in tendinopathy and chronic ruptures compared to acute ruptures. Inflammatory infiltration was detected by immunohistochemistry in all tendon pathology groups, but was significantly lower in tendinopathy compared to chronic ruptures. Quantitative real-time PCR (qRT-PCR analysis revealed significantly altered expression of genes related to collagens and matrix modeling/remodeling (matrix metalloproteinases, tissue inhibitors of metalloproteinases in tendinopathy and chronic ruptures compared to intact tendons and/or acute ruptures. In all three tendon pathology groups markers of inflammation (interleukin (IL 1β, tumor necrosis factor α, IL6, IL10, IL33, soluble ST2, transforming growth factor β1, cyclooxygenase 2, inflammatory cells (cluster of differentaition (CD 3, CD68, CD80, CD206, fat metabolism (fatty acid binding protein 4, peroxisome proliferator-activated receptor γ, CCAAT/enhancer-binding protein α, adiponectin, and innervation (protein gene product 9.5, growth associated protein 43, macrophage migration inhibitory factor were detectable, but only in acute ruptures significantly regulated compared to intact tendons. The study gives an insight into structural and molecular changes of pathological processes in tendons and might be used to identify targets for future therapy of tendon pathologies.

  11. A new method for measurement of subcoracoid outlet and its relationship to rotator cuff pathology at MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Porter, N.A.; Singh, J.; Tins, B.J.; Lalam, R.K.; Tyrrell, P.N.M.; Cassar-Pullicino, V.N. [Robert Jones and Agnes Hunt Orthopaedic Hospital, Department of Radiology, Oswestry, Shropshire (United Kingdom)

    2015-09-15

    Orthopaedic surgical studies have shown that variations in the vertical distance between the tip of the coracoid process and the supra-glenoid tubercle alter the shape of the subcoracoid outlet. Our objective was to measure the vertical distance between the coracoid tip and the supra-glenoid tubercle (CTGT) on MR and to assess whether this showed better correlation with rotator cuff pathology compared with the axial coraco-humeral distance. A retrospective review was performed of 100 consecutive shoulder MR arthrograms. Vertical distance between the coracoid tip and the supraglenoid tubercle was measured in the sagittal oblique plane. Separate assessment was then made of tendon pathology of the subscapularis, supraspinatus and long head of biceps tendons. Axial coraco-humeral distance was then measured. Correlation between tendon abnormalities and the two measurements was then made. Of the 100 cases, 42 had subscapularis tendon lesions, 21 had lesions of the long head of biceps and 53 had supraspinatus tendon lesions. Mean vertical distance from the coracoid tip to supraglenoid tubercle was greater in those with lesions of any of these tendons and was statistically significant for the supraspinatus group (P = 0.005). Reduced axial coraco-humeral distance was also seen in patients with tendinopathy, although with less statistically significant difference (p = 0.059). Our results support orthopaedic studies that have shown that the vertical distance between the coracoid tip and the supraglenoid tubercle increases the incidence and risk of rotator cuff disease by altering the shape of the subcoracoid outlet. (orig.)

  12. Floating knee injury associated with patellar tendon rupture: a case report and review of literature.

    Science.gov (United States)

    Vaidyanathan, Singaravadivelu; Panchanathan Ganesan, Jagannath; Moongilpatti Sengodan, Mugundhan

    2012-01-01

    Floating knee injuries are frequently associated with other concomitant injuries to the ipsilateral limb or other parts of body of which injury to the ipsilateral knee ligaments carries significance for various reasons. A middle-aged man sustained a floating knee injury following RTA. DCS fixation by bridge plating technique for the distal femur and lateral buttress plating by MIPO technique for proximal tibia were planned and executed under spinal anesthesia with image intensifier. In addition, there were patellar tendon rupture along with avulsion of VMO from the medial border of patella and torn MPFL, which we have missed initially. To the best of our knowledge no similar case has been reported in English literature so far. We have reviewed the literature and proposed a different interpretation of Blake and McBride classification.

  13. Floating Knee Injury Associated with Patellar Tendon Rupture: A Case Report and Review of Literature

    Directory of Open Access Journals (Sweden)

    Singaravadivelu Vaidyanathan

    2012-01-01

    Full Text Available Floating knee injuries are frequently associated with other concomitant injuries to the ipsilateral limb or other parts of body of which injury to the ipsilateral knee ligaments carries significance for various reasons. A middle-aged man sustained a floating knee injury following RTA. DCS fixation by bridge plating technique for the distal femur and lateral buttress plating by MIPO technique for proximal tibia were planned and executed under spinal anesthesia with image intensifier. In addition, there were patellar tendon rupture along with avulsion of VMO from the medial border of patella and torn MPFL, which we have missed initially. To the best of our knowledge no similar case has been reported in English literature so far. We have reviewed the literature and proposed a different interpretation of Blake and McBride classification.

  14. The effect of acute exercise on collagen turnover in human tendons

    DEFF Research Database (Denmark)

    Mørch, Lina Steinrud; Pingel, Jessica; Boesen, Mikael

    2013-01-01

    Mechanical loading of human tendon stimulates collagen synthesis, but the relationship between acute loading responses and training status of the tendon is not clear. We tested the effect of prolonged load deprivation on the acute loading-induced collagen turnover in human tendons, by applying...... the contra-lateral leg was used habitually. Following the procedure both Achilles tendons and calf muscles were loaded with the same absolute load during a 1-h treadmill run. Tissue collagen turnover was measured by microdialysis performed post-immobilization but pre-exercise around both Achilles tendons...... and compared to values obtained by 72-h post-exercise. Power Doppler was used to monitor alterations in intratendinous blood flow velocity of the Achilles tendon and MRI used to quantitate changes in tendon cross-section area. Acute loading resulted in an increased collagen synthesis 72 h after the run in both...

  15. Management of spastic hand by selective peripheral neurotomies

    African Journals Online (AJOL)

    Wael Fouad

    2011-08-20

    Aug 20, 2011 ... focalized on muscles that are under the control of a single or few peripheral nerves. Objective: This ... obtained by sectioning both afferents and efferents fibers of ... elbow, medial to the biceps brachii tendon; both median and.

  16. Arthroscopically-Asissted Achilles Tendon Repair; Long-Term Results

    OpenAIRE

    Turgut, Ak?n; Asfuro?lu, Mert Zeynel

    2014-01-01

    Objectives: The ruptures of the Achilles tendon (AT) are relatively common. Since there is no consensus on the best method of the repair of the AT; the treatment is determined on the preference of the surgeon and the patient. The study evaluating the cadaveric and short term clinical results done by our clinic in 2002, has shown us that arthroscopically Achilles tendon repair can be good choise in achilles tendon ruptures. Methods: Fortyfour patients who underwent arthroscopically assisted ac...

  17. Ossification of the bilateral Achilles tendon: a rare entity

    International Nuclear Information System (INIS)

    Arora, Abhishek J; Arora, Richa

    2015-01-01

    Ossification of the Achilles tendon is a rare clinical entity comprising of one or more segments of variable sized ossified masses in the fibrocartilaginous substance of the tendon. The etiology of ossification of the Achilles tendon is multifactorial with recurrent trauma and surgery comprising major predisposing factors, with others being metabolic, systemic, and infectious diseases. The possibility of a genetic predisposition towards this entity has also been raised, but has not yet been proven. We present a rare case of ossification of the bilateral Achilles tendons without any history of trauma or surgery in a 48-year-old female patient

  18. HGF mediates the anti-inflammatory effects of PRP on injured tendons.

    Directory of Open Access Journals (Sweden)

    Jianying Zhang

    Full Text Available Platelet-rich plasma (PRP containing hepatocyte growth factor (HGF and other growth factors are widely used in orthopaedic/sports medicine to repair injured tendons. While PRP treatment is reported to decrease pain in patients with tendon injury, the mechanism of this effect is not clear. Tendon pain is often associated with tendon inflammation, and HGF is known to protect tissues from inflammatory damages. Therefore, we hypothesized that HGF in PRP causes the anti-inflammatory effects. To test this hypothesis, we performed in vitro experiments on rabbit tendon cells and in vivo experiments on a mouse Achilles tendon injury model. We found that addition of PRP or HGF decreased gene expression of COX-1, COX-2, and mPGES-1, induced by the treatment of tendon cells in vitro with IL-1β. Further, the treatment of tendon cell cultures with HGF antibodies reduced the suppressive effects of PRP or HGF on IL-1β-induced COX-1, COX-2, and mPGES-1 gene expressions. Treatment with PRP or HGF almost completely blocked the cellular production of PGE2 and the expression of COX proteins. Finally, injection of PRP or HGF into wounded mouse Achilles tendons in vivo decreased PGE2 production in the tendinous tissues. Injection of platelet-poor plasma (PPP however, did not reduce PGE2 levels in the wounded tendons, but the injection of HGF antibody inhibited the effects of PRP and HGF. Further, injection of PRP or HGF also decreased COX-1 and COX-2 proteins. These results indicate that PRP exerts anti-inflammatory effects on injured tendons through HGF. This study provides basic scientific evidence to support the use of PRP to treat injured tendons because PRP can reduce inflammation and thereby reduce the associated pain caused by high levels of PGE2.

  19. HGF Mediates the Anti-inflammatory Effects of PRP on Injured Tendons

    Science.gov (United States)

    Zhang, Jianying; Middleton, Kellie K.; Fu, Freddie H.; Im, Hee-Jeong; Wang, James H-C.

    2013-01-01

    Platelet-rich plasma (PRP) containing hepatocyte growth factor (HGF) and other growth factors are widely used in orthopaedic/sports medicine to repair injured tendons. While PRP treatment is reported to decrease pain in patients with tendon injury, the mechanism of this effect is not clear. Tendon pain is often associated with tendon inflammation, and HGF is known to protect tissues from inflammatory damages. Therefore, we hypothesized that HGF in PRP causes the anti-inflammatory effects. To test this hypothesis, we performed in vitro experiments on rabbit tendon cells and in vivo experiments on a mouse Achilles tendon injury model. We found that addition of PRP or HGF decreased gene expression of COX-1, COX-2, and mPGES-1, induced by the treatment of tendon cells in vitro with IL-1β. Further, the treatment of tendon cell cultures with HGF antibodies reduced the suppressive effects of PRP or HGF on IL-1β-induced COX-1, COX-2, and mPGES-1 gene expressions. Treatment with PRP or HGF almost completely blocked the cellular production of PGE2 and the expression of COX proteins. Finally, injection of PRP or HGF into wounded mouse Achilles tendons in vivo decreased PGE2 production in the tendinous tissues. Injection of platelet-poor plasma (PPP) however, did not reduce PGE2 levels in the wounded tendons, but the injection of HGF antibody inhibited the effects of PRP and HGF. Further, injection of PRP or HGF also decreased COX-1 and COX-2 proteins. These results indicate that PRP exerts anti-inflammatory effects on injured tendons through HGF. This study provides basic scientific evidence to support the use of PRP to treat injured tendons because PRP can reduce inflammation and thereby reduce the associated pain caused by high levels of PGE2. PMID:23840657

  20. Knee dislocations: a magnetic resonance imaging study correlated with clinical and operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Bui, Kimmie L. [Cleveland Clinic, Department of Radiology, Cleveland, OH (United States); Cleveland Clinic, Department of Radiology, HB6, Cleveland, OH (United States); Ilaslan, Hakan; Sundaram, Murali [Cleveland Clinic, Department of Radiology, Cleveland, OH (United States); Parker, Richard D. [Cleveland Clinic, Department of Orthopaedics, Cleveland, OH (United States)

    2008-07-15

    Our objectives were to determine retrospectively the prevalence, patients' demographics, mechanism of injury, combination of torn ligaments, associated intra-articular and extra-articular injuries, fractures, bone bruises, femoral-tibial alignment and neurovascular complications of knee dislocations as evaluated by magnetic resonance (MR) imaging. From 17,698 consecutive knee examinations by magnetic resonance imaging (MRI) over a 6-year period, 20 patients with knee dislocations were identified. The medical records of these patients were subsequently reviewed for relevant clinical history, management and operative findings. The prevalence of knee dislocations was 0.11% [95% confidence interval (95% CI) 0.06-0.16]. There were 16 male patients and four female patients, with ages ranging from 15 years to 76 years (mean 31 years). Fifteen patients had low-velocity injuries (75%), of which 11 were amateur sports related and four were from falls. Four patients (20%) had suffered high-velocity trauma (motor vehicle accidents). One patient had no history available. Anatomic alignment was present at imaging in 16 patients (80%). Eighteen patients had three-ligament tears, two had four-ligament tears. The four-ligament tears occurred with low-velocity injuries. The anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) were torn in every patient; the lateral collateral ligament (LCL) was torn in 50%, and the medial collateral ligament (MCL) in 60%. Intra-articular injuries included meniscal tears (five in four patients), fractures (eight in seven patients), bone bruises (15 patients), and patellar retinaculum tears (eight partial, two complete). The most common extra-articular injury was a complete biceps femoris tendon tear (five, 25%). There were two popliteal tendon tears and one iliotibial band tear. One patient had received a vascular injury following a motor vehicle accident (MVA) and had been treated prior to undergoing MRI. Bone bruises

  1. Bilateral synchronous rupture of the quadriceps tendon.

    LENUS (Irish Health Repository)

    Ellanti, P

    2012-09-01

    Bilateral simultaneous rupture of the quadriceps tendon is a rare entity. They are often associated with degenerative changes of the tendons and predisposing conditions such as diabetes or excessive steroid use. They most commonly tend to occur in patients of 40 years of age or older.

  2. Nonlinear model for viscoelastic behavior of Achilles tendon.

    Science.gov (United States)

    Kahn, Cyril J F; Wang, Xiong; Rahouadj, Rachid

    2010-11-01

    Although the mechanical properties of ligament and tendon are well documented in research literature, very few unified mechanical formulations can describe a wide range of different loadings. The aim of this study was to propose a new model, which can describe tendon responses to various solicitations such as cycles of loading, unloading, and reloading or successive relaxations at different strain levels. In this work, experiments with cycles of loading and reloading at increasing strain level and sequences of relaxation were performed on white New Zealand rabbit Achilles tendons. We presented a local formulation of thermodynamic evolution outside equilibrium at a representative element volume scale to describe the tendon's macroscopic behavior based on the notion of relaxed stress. It was shown that the model corresponds quite well to the experimental data. This work concludes with the complexity of tendons' mechanical properties due to various microphysical mechanisms of deformation involved in loading such as the recruitment of collagen fibers, the rearrangement of the microstructure (i.e., collagens type I and III, proteoglycans, and water), and the evolution of relaxed stress linked to these mechanisms.

  3. The role of ultrasound in the management of flexor tendon injuries.

    Science.gov (United States)

    Jeyapalan, K; Bisson, M A; Dias, J J; Griffin, Y; Bhatt, R

    2008-08-01

    The use of ultrasound scanning to establish tendon pathologies was assessed retrospectively in 17 patients in 18 digits. The ultrasound scan demonstrated four patterns: (1) normal intact tendons in four, (2) ruptured tendons in three, (3) tendons in continuity but attenuated in five and (4) tendons in continuity but thickened with fibrosis and decreased movement representing adhesions in five patients. Surgery was undertaken in only three cases, confirming the ultrasound diagnosis in two. Surgery was offered to all three patients with ruptures but was declined by two. Ultrasound imaging helped to avoid surgery in 14 cases by excluding flexor tendon re-ruptures. This allowed on-going mobilisation, leading to recovery of function.

  4. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    Science.gov (United States)

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  5. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kairui; Zhang, Sheng [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Li, Qianqian [Cancer Research Institute, Southern Medical University, Guangzhou 510515 (China); Yang, Jun [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Department of Orthopaedics, 421 Hospital of PLA, Guangzhou 510318 (China); Dong, Weiqiang [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Department of Orthopaedics, The First Affiliated Hospital to Guangzhou Medical University, Guangzhou 510120 (China); Wang, Shengnan; Cheng, Yirong; Al-Qwbani, Mohammed [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Wang, Qiang, E-mail: 1780468505@qq.com [Department of Orthopaedics, Subei People’s Hospital of Jiangsu Province (Clinical Medical College of Yangzhou University), Yangzhou, Jiangsu Province 225001 (China); Yu, Bin, E-mail: carryzhang1985@live.com [Department of Orthopaedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China)

    2014-07-18

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aims to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation.

  6. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    International Nuclear Information System (INIS)

    Zhang, Kairui; Zhang, Sheng; Li, Qianqian; Yang, Jun; Dong, Weiqiang; Wang, Shengnan; Cheng, Yirong; Al-Qwbani, Mohammed; Wang, Qiang; Yu, Bin

    2014-01-01

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aims to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation

  7. Bevacizumab Improves Achilles Tendon Repair in a Rat Model

    Directory of Open Access Journals (Sweden)

    Herbert Tempfer

    2018-04-01

    Full Text Available Background/Aims: Effective wound-healing generally requires efficient re-vascularization after injury, ensuring sufficient supply with oxygen, nutrients, and various cell populations. While this applies to most tissues, tendons are mostly avascular in nature and harbor relatively few cells, probably contributing to their poor regenerative capacity. Considering the minimal vascularization of healthy tendons, we hypothesize that controlling angiogenesis in early tendon healing is beneficial for repair tissue quality and function. Methods: To address this hypothesis, Bevacizumab, a monoclonal antibody blocking VEGF-A signaling, was locally injected into the defect area of a complete tenotomy in rat Achilles tendon. At 28 days post-surgery, the defect region was investigated using immunohistochemistry against vascular and lymphatic epitopes. Polarization microscopy and biomechanical testing was used to determine tendon integrity and gait analysis for functional testing in treated vs non-treated animals. Results: Angiogenesis was found to be significantly reduced in the Bevacizumab treated repair tissue, accompanied by significantly reduced cross sectional area, improved matrix organization, increased stiffness and Young’s modulus, maximum load and stress. Further, we observed an improved gait pattern when compared to the vehicle injected control group. Conclusion: Based on the results of this study we propose that reducing angiogenesis after tendon injury can improve tendon repair, potentially representing a novel treatment-option.

  8. Achilles tendon shape and echogenicity on ultrasound among active badminton players.

    Science.gov (United States)

    Malliaras, P; Voss, C; Garau, G; Richards, P; Maffulli, N

    2012-04-01

    The relationship between Achilles tendon ultrasound abnormalities, including a spindle shape and heterogeneous echogenicity, is unclear. This study investigated the relationship between these abnormalities, tendon thickness, Doppler flow and pain. Sixty-one badminton players (122 tendons, 36 men, and 25 women) were recruited. Achilles tendon thickness, shape (spindle, parallel), echogenicity (heterogeneous, homogeneous) and Doppler flow (present or absent) were measured bilaterally with ultrasound. Achilles tendon pain (during or after activity over the last week) and pain and function [Victorian Institute of Sport Achilles Assessment (VISA-A)] were measured. Sixty-eight (56%) tendons were parallel with homogeneous echogenicity (normal), 22 (18%) were spindle shaped with homogeneous echogenicity, 16 (13%) were parallel with heterogeneous echogenicity and 16 (13%) were spindle shaped with heterogeneous echogenicity. Spindle shape was associated with self-reported pain (P<0.05). Heterogeneous echogenicity was associated with lower VISA-A scores than normal tendon (P<0.05). There was an ordinal relationship between normal tendon, parallel and heterogeneous and spindle shaped and heterogeneous tendons with regard to increasing thickness and likelihood of Doppler flow. Heterogeneous echogenicity with a parallel shape may be a physiological phase and may develop into heterogeneous echogenicity with a spindle shape that is more likely to be pathological. © 2010 John Wiley & Sons A/S.

  9. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  10. Achilles tendon repair

    Science.gov (United States)

    ... your Achilles tendon to point your toes and push off your foot when walking. If your Achilles ... MD, Thompson SR, eds. DeLee and Drez's Orthopaedic Sports Medicine: Principles and Practice . 4th ed. Philadelphia, PA: ...

  11. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  12. Postoperative US of leg tendon reconstruction

    International Nuclear Information System (INIS)

    Draghi, F.; Calliada, F.; Fulle, I.; Madonia, L.; Bottinelli, O.; Campani, R.

    1999-01-01

    The role of ultrasound (US) in the postoperative assessment of tendon reconstruction is not clearly defined and there is non systematic arrangement of US patterns. The authors examined 34 patients submitted to surgery or conservative treatment for total/partial tear or musculotendinous detachment of patellar or Achilles tendon in the last 5 years. All patients underwent physical and US examinations. The surgical tendon exhibited the same US patterns in 23/28 patients: it was markedly enlarged (three-/fourfold the normal diameter) and more rounded, with inhomogeneous and hypoechoic appearance not only at the tear/surgical site but also above and below it, for some cm. Small hyperechoic images, mainly dots, were seen in 19 cases, which were referable to small calcifications and stitches. More and larger calcifications were found in 8 patients, where they were associated with anechoic degeneration areas. Color Doppler US showed moderate or strong hypervascularization around the tear in the first months post injury. US patterns did not correlate with physical findings, but color Doppler patterns did. In 6 cases of musculotendinous detachment submitted to conservative treatment, US showed enlargement and hypoechogenicity in the injury site only, with no involvement of the remaining tendon. US was also used to time and guide drainage of perilesional hematomas, which were often quite large. US is the method of choice in the postoperative follow-up of tendon tears and musculotendinous detachments because it shows abnormal signs which are missed at clinics and provides additional information needed for treatment planning [it

  13. High-resolution US and MR imaging of peroneal tendon injuries.

    Science.gov (United States)

    Taljanovic, Mihra S; Alcala, Jennifer N; Gimber, Lana H; Rieke, Joshua D; Chilvers, Margaret M; Latt, L Daniel

    2015-01-01

    Injuries of the peroneal tendon complex are common and should be considered in every patient who presents with chronic lateral ankle pain. These injuries occur as a result of trauma (including ankle sprains), in tendons with preexisting tendonopathy, and with repetitive microtrauma due to instability. The peroneus brevis and peroneus longus tendons are rarely torn simultaneously. Several anatomic variants, including a flat or convex fibular retromalleolar groove, hypertrophy of the peroneal tubercle at the lateral aspect of the calcaneus, an accessory peroneus quartus muscle, a low-lying peroneus brevis muscle belly, and an os peroneum, may predispose to peroneal tendon injuries. High-resolution 1.5-T and 3-T magnetic resonance (MR) imaging with use of dedicated extremity coils and high-resolution ultrasonography (US) with high-frequency linear transducers and dynamic imaging are proved to adequately depict the peroneal tendons for evaluation and can aid the orthopedic surgeon in injury management. An understanding of current treatment approaches for partial- and full-thickness peroneal tendon tears, subluxation and dislocation of these tendons with superior peroneal retinaculum (SPR) injuries, intrasheath subluxations, and peroneal tendonopathy and tenosynovitis can help physicians achieve a favorable outcome. Patients with low functional demands do well with conservative treatment, while those with high functional demands may benefit from surgery if nonsurgical treatment is unsuccessful. Radiologists should recognize the normal anatomy and specific pathologic conditions of the peroneal tendons at US and MR imaging and understand the various treatment options for peroneal tendon and SPR superior peroneal retinaculum injuries. Online supplemental material is available for this article. RSNA, 2015

  14. Achilles tendon and sports; Die Achillessehne im Sport

    Energy Technology Data Exchange (ETDEWEB)

    Ulreich, N.; Kainberger, F. [Univ.-Klinik fuer Radiodiagnostik Wien (Austria); Huber, W.; Nehrer, S. [Univ.-Klinik fuer Orthopaedie Wien (Austria)

    2002-10-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [German] Aufgrund des starken Anstiegs des Freizeitsportes sind Achillodynien ein besonders mit Laufsport, Fussball und Leichtathletik assoziiertes Symptom und die Indikation zur radiologischen Abklaerung wird oft gestellt. Die Entstehung von Sehnenschaeden wird durch eine Reihe von Hypothesen erklaert, wobei eine gestoerte Gewebeperfusion und eine mechanische Irritation als Hauptursachen angesehen werden, die zur Degeneration des Sehnengewebes und des umgebenden Gleitlagers fuehren. Sie koennen aufgrund sonographischer und MR-tomographischer Zeichen meist klar klassifiziert und graduiert werden, wobei hochaufloesende Techniken eine wesentliche Voraussetzung fuer die subtile Analyse der Sehnenstruktur darstellen. Die einzelnen klinischen Erscheinungsformen wie Tendinose, Achillobursitis, Haglund-Ferse und Sehnenruptur koennen unter dem Begriff des ''Sehnenueberlastungssyndroms'' (Tendon overuse syndrome) subsummiert werden. Rupturen der Achillessehne treten so gut wie immer bei bereits vorgeschaedigtem Kollagenfasergewebe auf, und der radiologischen Diagnostik kommt wesentliche Bedeutung dabei zu

  15. Simulation of tendon energy storage in pedaling

    DEFF Research Database (Denmark)

    Rasmussen, John; Damsgaard, Michael; Christensen, Søren Tørholm

    2001-01-01

    The role of elastic energy stored in tendons during pedaling is investigated by means of numerical simulation using the AnyBody body modeling system. The loss of metabolic energy due to tendon elasticity is computed and compared to the mechanical work involved in the process. The AnyBody simulati...

  16. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats

    Science.gov (United States)

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis. PMID:27078690

  17. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats.

    Directory of Open Access Journals (Sweden)

    Diego Pulzatto Cury

    Full Text Available Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis.

  18. PERONEAL TENDON LESIONS IN ATHLETES (REVIEW

    Directory of Open Access Journals (Sweden)

    E. E. Achkasov

    2016-01-01

    Full Text Available The authors analyzed scientific literature in respect of various issues in treatment of athletes with peroneal muscles lesions starting from 1987 till 2016. Key search and publications selection was made in PubMed and russian national electronic scientific library eLIBRARY. Peroneal tendons pathology is not the major but the underestimated cause of pain in lateral and hindfoot as well as of foot dysfunction which is difficult to distinguish from lesions of lateral ligaments of the ankle joint. Untreated lesions of peroneal tendons can result in chronic ankle pain and significant functional disorders. The purpose of the present paper is to improve the current comprehension of anatomy, to identify factors contributing to pathology, to perform diagnostic evaluation of peroneal tendons and to review current treatment options of such lesions.

  19. Presence of a long accessory flexor tendon of the toes in surgical treatment for tendinopathy of the insertion of the calcaneal tendon: case report

    Directory of Open Access Journals (Sweden)

    Nelson Pelozo Gomes Júnior

    2016-02-01

    Full Text Available ABSTRACT The presence of accessory tendons in the foot and ankle needs to be recognized, given that depending on their location, they may cause disorders relating either to pain processes or to handling of the surgical findings. We describe the presence of an accessory flexor tendon of the toes, seen in surgical exposure for transferring the long flexor tendon of the hallux to the calcaneus, due to the presence of a disorder of tendinopathy of the insertion of the calcaneal tendon in association with Haglund's syndrome.

  20. Modified rerouting procedure for failed peroneal tendon dislocation surgery.

    Science.gov (United States)

    Gaulke, R; Hildebrand, F; Panzica, M; Hüfner, T; Krettek, C

    2010-04-01

    Recurrent dislocation of the peroneal tendons following operative treatment is relatively uncommon, but can be difficult to treat. We asked whether subligamental transposition of the peroneus brevis tendon, fibular grooving, and reattachment of the superior peroneal retinaculum for failed peroneal tendon dislocation surgery would achieve a stable fixation of the peroneal tendons and whether there would be restrictions of ROM or instability of the hindfoot. We reviewed six female patients (mean age, 24.5 years) with general laxity of joints preoperatively and at 6 weeks and 3, 6, and 12 months postoperatively. Within 1 year postoperatively no recurrence was found. In two ankles the extension was restricted 5 degrees to 10 degrees . In another pronation and supination was restricted 5 degrees each. Stability of the ankle increased in four patients and stayed unchanged in two. AOFAS score increased from a mean value of 36 +/- 20.6 preoperatively to 90 +/- 7 postoperatively at 1 year. We conclude transposition of the peroneus brevis tendon is a reasonable treatment for failed peroneal tendon dislocation surgery. Level IV, therapeutic study (prospective case series). See Guidelines for Authors for a complete description of levels of evidence.